WorldWideScience

Sample records for international monitoring system

  1. International Remote Monitoring Project Embalse Nuclear Power Station, Argentina Embalse Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, Sigfried L.; Glidewell, Donnie D.; Bonino, Anibal; Bosler, Gene; Mercer, David; Maxey, Curt; Vones, Jaromir; Martelle, Guy; Busse, James; Kadner, Steve; White, Mike; Rovere, Luis

    1999-01-01

    The Autoridad Regulatoria Nuclear of Argentina (ARN), the International Atomic Energy Agency (IAEA), ABACC, the US Department of Energy, and the US Support Program POTAS, cooperated in the development of a Remote Monitoring System for nuclear nonproliferation efforts. This system was installed at the Embalse Nuclear Power Station last year to evaluate the feasibility of using radiation sensors in monitoring the transfer of spent fuel from the spent fuel pond to dry storage. The key element in this process is to maintain continuity of knowledge throughout the entire transfer process. This project evaluated the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguard efficiency. New technology has been developed to enhance the design of the system to include storage capability on board sensor platforms. This evaluation has led to design enhancements that will assure that no data loss will occur during loss of RF transmission of the sensors

  2. Development of web based system for internal monitoring programme

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Vanessa R. de; Rodrigues Junior, Orlando; Todo, Alberto S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: vrlima@ipen.br; rodrijr@ipen.br; astodo@ipen.br

    2007-07-01

    The purposes of monitoring in general are to verify and to document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, it forms part of the overall radiation protection programme, which starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  3. Development of Web based system for individual internal monitoring programme

    International Nuclear Information System (INIS)

    Lima, Vanessa Rogeria de

    2007-01-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  4. Brazilian participation in the International Monitoring System for Nuclear Explosions

    International Nuclear Information System (INIS)

    Veloso, Jose Alberto Vivas

    1995-01-01

    On January 1, 1995, Brazil was integrated to the world-wide seismic system, through the Seismological Observatory of the University of Brasilia, dedicated to detect and identify underground nuclear explosions. This is an unprecedented global effort program to conduct a seismic test of rapid data collection, distribution and processing evolving the most advanced sensors, global communications and data processing technologies. By the end of February, 49 countries were incorporated and the present test represents a first training step towards the final definition of an International Monitoring System to monitoring a Comprehensive test Band Treaty. Besides accomplishing its main goal, the global monitoring program will be able to supply rapidly, through the International Data Center, important information to the seismological community. (author). 2 figs

  5. Web system for dosimetric data management of internal monitoring programme at IPEN

    International Nuclear Information System (INIS)

    Lima, Vanesa R. de; Rodriguez Junior, Orlando; Todo, Alberto S.

    2008-01-01

    Full text: The internal monitoring programme are carried out for the occupationally exposed workers that develop activities in the radioisotope production plant, fuel cycle facilities, waste management installations, cyclotron and the reactor facility at Institute of Nuclear Energy and Research (IPEN). According to the National Nuclear Energy Commission (CNEN), Regulation NN-3.01, the dose of each worker should be maintained at least for a period of 30 years. With this purpose, an online system, called 'IntDosWeb', was developed with the objective of the management for data dosimetric of internal monitoring programme. The system IntDosWeb, based on free software, was developed in programming language PHP and environment database PostgreSQL. This system is to be available at the local net, Intranet. The database maintains information about identification of the worker that handles non-sealed radioactive sources, physical and chemical characteristics of the radionuclides, monitoring types, measurement data and the dose. This system is able to generate annual reports of the individuals and the historical dose. Several simulation cases have been put into effect to check the on-line software functional capabilities. The users can access the dosimetric information according to following database field: monitoring period, monitoring type, intake pattern, radionuclide type and monitoring data from a specific installation or from each worker. The system was tested in the routinely service of internal dosimetry at IPEN. The rastreability of the information made in the internal monitoring programme was a success and also guaranteeing the reliability and integrity of the stored information. The IntDosWeb was shown as a helpful tool for analysis of the committed effective dose in the radiation protection programme, besides obeying the legal demands of the Brazilian Regulatory Commission. (author)

  6. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  7. GSETT-3: testing the experimental international seismic monitoring system

    International Nuclear Information System (INIS)

    Ringdal, Frode

    1995-01-01

    Global seismic monitoring system has been developed by the Conference on Disarmaments (CDs) ad hoc group of scientific experts to consider international cooperative measures to detect and identify seismic events (the GSE), based in Geneva. In the course of its work, the GSE has conducted two large-scale global technical tests, Global Seismic Events Technical Test-1 (GSETT-1) in 1984 and GSETT-2 in 1991. The GSE has now embarked upon its third and most ambitious technical test, GSETT-3, which will encompass the development, testing and evaluation of a working prototype of the eventual Comprehensive Test Ban Treaty (CTBT) seismic monitoring system

  8. ENHANCING ASSETS' PROTECTION THROUGH AN ADEQUATE MONITORING OF INTERNAL CONTROL SYSTEM BY INTERNAL AUDIT

    Directory of Open Access Journals (Sweden)

    Dan Eugen Cosmin

    2011-12-01

    Full Text Available The assets are established into a company as very important and strategic resources that are contributing at the creation of the needed premises to conduct the daily-basis activity and also to reach present and future planned objectives. Recent studies like COSO's Fraudulent Financial Reporting 1998-2007 have highlighted an increasing fraudulent activity against assets therefore the efforts of fighting against fraud must be supplemented in order to preserve the existence and value of those resources. Internal controls are processes implemented in order to give a reasonable assurance that the company will not become a fraud victim. Even so, a lot of internal controls are paying a heavy tribute to their lack of efficiency and update. Thus, for a correct functioning, internal controls must be monitored and assessed permanently in order to preserve their strength and ability to fulfill their mission. This approach will deliver more added value because rather than being corrected after they have already occurred, the frauds related with the assets will be prevented, detected and reported at a timely moment, thereby the incidence and value of those criminal activities will decrease significantly. Furthermore, because not only the process of monitoring is important but even the entity conducting this activity we believe that internal audit is the most appropriate to undertake this responsibility. Thus, through this material we opened a discussion about how important permanent monitored and updated internal controls are in order to assure a proper assets protection and why internal audit, rather than the management, should be the most eligible to undertake this responsibility. Also we provided some suggestions regarding the main activities that must be taken into consideration by an internal audit professional when is being involved in a monitoring process of internal control system. We do believe that this paper will be the starting point for new

  9. Remote monitoring in international safeguards

    International Nuclear Information System (INIS)

    Dupree, S.A.; Sonnier, C.S.; Johnson, C.S.

    1996-01-01

    In recent years, technology that permits the integration of monitoring sensors and instruments into a coherent network has become available. Such integrated monitoring systems provide a means for the automatic collection and assessment of sensor signals and instrument readings and for processing such signals and readings in near real time. To gain experience with the new monitoring system technology, the US Department of energy, through bilateral agreements with its international partners, has initiated a project to emplace demonstration systems in various nuclear facilities and conduct field trials of the technology. This effort is the International Remote Monitoring Project. Under this project, remote monitoring systems are being deployed around the world in an incremental manner. Each deployment is different and each offers lessons for improving the performance and flexibility of the technology. Few problems were encountered with the operation of the installations to date, and much has been learned about the operation and use of the new technology. In the future, the authors believe systems for safeguards applications should be capable of being monitored remotely, emphasize the use of sensors, and utilize selective triggering for recording of images. Remote monitoring across national borders can occur only in the context of a cooperative, nonadversarial implementation regime. However, significant technical and policy work remains to be done before widespread safeguards implementation of remote monitoring should be considered. This paper shows that an abundance of technology supports the implementation of integrated and remote monitoring systems. Current field trials of remote monitoring systems are providing practical data and operational experience to aid in the design of tomorrow's systems

  10. The international remote monitoring project and implication

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    The future of remote monitoring in International Safeguards system is analyzed. Problems of an update on the International Remote Monitoring Project are considered. The Project allows to remotely transmit safeguards-relevant data directly to IAEA from nuclear facilities worldwide. Description of integrated monitoring system (IMS) is given. A key element of state-of-art of IMS is modular nodal system which accepts information from sensors and provides information to both a data storage unit and a transmitter. Remote Monitoring Systems of Australia and Sweden are presented. 3 figs

  11. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  12. The CTBT : New Zealand's involvement in the international monitoring system

    International Nuclear Information System (INIS)

    Matthews, M.

    1998-01-01

    The Comprehensive Test-Ban Treaty (CTBT), to which most countries are now signatories, is seen as a major step towards the curtailment of nuclear weapons production and eventual disarmament. The Treaty can only be effectively implemented, however, if there is a monitoring system in place to verify that weapons testing is not taking place and, if it does occur, to identify the violator. The diesign of the International Monitoring System (IMS) has therefore been a significant part of the Treaty negotiations. This article focuses o New Zealand's involvement in the IMS, in atmospheric radioactivity and infrasound monitoring. Because of its history of involvement in environmental monitoring, National Radiation Laboratory (NRL) has been providing expert input into Treaty negotiations concerning the radionucled component of the IMS. The Institute of Geological and Nuclear Sciences (IGNS) monitors seismic activity at a number of locations in New Zealand and the South Pacific, and has also provided expert input to the design of the global seismic component of the IMS. The New Zealand government has offered the monitoring facilities of NRL and IGNS for inclusion in the global IMS. (author)

  13. The International Monitoring System's Noble Gas Network

    International Nuclear Information System (INIS)

    Auer, M.

    2015-01-01

    The International Monitoring System (IMS) is a unique global network for surveillance of the Comprehensive Nuclear-Test-Ban Treaty. A major component of the IMS is the radionuclide monitoring network since, among all IMS technologies, it can provide the most unequivocal evidence for a nuclear explosion. The radionuclide monitoring component is unprecedented in its combination of global coverage, sensitivity, network density and temporal resolution. In particular for the detection of underground or underwater nuclear tests, forty of the eighty radionuclide stations will eventually be equipped with sensors to measure the Xenon isotopes Xe-131m (τ 1/2 = 11:8 d), Xe-133 (τ 1/2 = 5:25 d), Xe-133m (τ 1/2 = 2:2 d) and Xe-135 (τ 1/2 = 9:14 h). These are among the isotopes with the highest yields in fission of uranium or plutonium with half-lives long enough to be detected at large distances from the point of emission. As of today, 31 noble gas systems have been installed and are sending data to the International Data Centre. The noble gas systems installed at the stations are automated and sample Xenon continuously from atmospheric air for 12 or 24 hours at an air flow of 0.5 to several m 3 /h by absorption of Xenon on activated charcoal. Detection of the Xenon isotopes is either by high resolution gamma spectrometry or by beta-gamma coincidence spectrometry. With the currently available equipment, detection limits of 0.2 mBq/m 3 can be achieved. An overview on the existing technology and future developments as well as on the interpretation of measurement results is given. (author)

  14. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  15. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  16. International systems for harmonization and quality control by in vivo monitoring and quality control by in vivo monitoring of internal contamination

    Energy Technology Data Exchange (ETDEWEB)

    Malatova, I [National Radiation Protection Inst., Prague (Czech Republic)

    1996-12-31

    After the Chernobyl accident, whole body counting for the monitoring of internal contamination of the population was widely used. In many cases, great discrepancy occurred between in vivo measured values and predicted ones from model calculations. This situation was very similar to the situation in environmental monitoring, however, by sample measurement, quality assurance and quality control of the measurement procedure is much easier than by whole body counting. In addition to it, unlike in environmental monitoring, use of semiconductor detectors by whole counting was rather limited in this time so there were few laboratories which were able to distinguish up to 20 radionuclides by which people from the vicinity of Chernobyl were internally contaminated. Therefore, effort was undertaken by many international organization to summarize current status of whole body counting and to estimate uncertainty and sensitivity of different devices. In this paper efforts to harmonize an interpretation of measured results is given. Whole body counting laboratory of the National Radiation Protection Institute (NRPI) in Prague participates in the above mentioned intercomparisons with good results and scientists from NRPI have participated in the preparation of 3 international recommendations concerning measurement of internal contamination (author).

  17. International experience feedback on fatigue monitoring systems for nuclear power plants

    International Nuclear Information System (INIS)

    Morilhat, P.

    1997-01-01

    From the very beginning of electro-nuclear programmes the need has become internationally obvious to develop systems aiming at automation and improvement of monitoring of the transients stressing the main mechanical components of nuclear units, by checking the conservativeness of the design no longer from a comparison of causes (temperature and pressure variations) but by directly assessing the results (stresses and linked damage). Prototypes of such systems have appeared since the middle of the 1980's mainly in France, the USA and Germany, and manufacturing them has since continued. Several years of development and on site testing of prototypes of fatigue measuring devices designed by the R and D Direction have enabled contacts with the developers of similar systems to be established and, in some cases, comparisons to be made. The experience accumulated in the use of such systems, both in France and abroad from now on makes a first experience feedback possible. The fatigue measuring device concept is based on a succession of elementary modules which enable the information received from the unit to be processed, first in the form of transient counting (transient meters), then in the form of mechanical diagnosis (fatigue monitoring systems). Among the systems in operation some provide actually only the transient meter part while others link transient meters and fatigue meters (EDF, EPRI and MITSUBISHI systems and some versions of the SIEMENS system). Moreover, numerous systems require, in addition to unit operation instrumentation, specific instrumentation located in monitored areas. The number of devices in operation has not stopped growing since the middle of the 80's to reach 53 systems working in 1996. The biggest developers are EPRI and its consultant Structural Integrity Associates (FatiguePro system), SIEMENS (FAMOS system) and EDF whose gradual implementation of SYSFAC from '96 is going to make its share particularly increase. Technical experience feedback

  18. Ground truth data collection on mining industrial explosions registered by the International Monitoring System

    International Nuclear Information System (INIS)

    Ehl'tekov, A.Yu.; Gordon, V.P.; Firsov, V.A.; Chervyakov, V.B.

    2004-01-01

    The presentation is dedicated to organizational and technical issues connected with the task of Comprehensive Test-Ban-Treaty Organization timely notification on large chemical explosions including data on explosion location and time, on applied explosive substance quantity and type, and also on configuration and assumed purpose of explosion. Explosions registered by International Monitoring System are of special interest. Their data could be used for calibration of the monitoring system. Ground truth data collection and some explosions location results on Russia's mining enterprises were given. Ground truth data collection peculiarities according to mining industrial explosions were considered. (author)

  19. The potential use of domestic safeguards interior monitors in International Safeguards

    International Nuclear Information System (INIS)

    Williams, J.D.; Dupree, S.A.; Sonnier, C.S.

    1998-01-01

    An important future element of International Safeguards instrumentation is expected to be the merging of containment/surveillance and nondestructive assay equipment with domestic physical protection equipment into integrated systems, coupled with remote monitoring. Instrumentation would include interior monitoring and assessment and entry/exit monitoring. Of particular importance is the application of interior monitors in spaces of declared inactivity; for example, in nuclear material storage locations that are entered infrequently. The use of modern interior monitors in International Safeguards offers potential for improving effectiveness and efficiency. Within the context of increased cooperation, one can readily envision increased interaction between International Safeguards and Domestic Safeguards, including increased joint use of State System of Accounting and Control data

  20. Management of bank risks in the system of internal financial monitoring

    Directory of Open Access Journals (Sweden)

    O.V. Lysenok

    2015-09-01

    Full Text Available Risk is an integral part of banking activities. That is why there are many researches on definition, measurement and monitoring of banking risks. Nowadays it is important to improve the risk management process of legalization (laundering of proceeds from crime or terrorist financing, especially in the present conditions of socio-economic development. This will improve the quality of financial monitoring in the country as a whole and will reduce the risk of attracting banks to laundering money from crime. The article reviews and examines modern management techniques and risk assessment of laundering proceeds from crime. The authors make suggestions to strengthen the tracking and detection of illegal schemes and appropriate approaches to «launder» criminal money. They also offer an appropriate model to manage the risks which accompany the process of laundering the proceeds from crime. According to the study carried out the authors provide their conclusions and recommendations to improve risk management in the system of internal financial monitoring of banks.

  1. Life Support and Environmental Monitoring International System Maturation Team Considerations

    Science.gov (United States)

    Anderson, Molly; Gatens, Robyn; Ikeda, Toshitami; Ito, Tsuyoshi; Hovland, Scott; Witt, Johannes

    2016-01-01

    Human exploration of the solar system is an ambitious goal. Future human missions to Mars or other planets will require the cooperation of many nations to be feasible. Exploration goals and concepts have been gathered by the International Space Exploration Coordination Group (ISECG) at a very high level, representing the overall goals and strategies of each participating space agency. The Global Exploration Roadmap published by ISECG states that international partnerships are part of what drives the mission scenarios. It states "Collaborations will be established at all levels (missions, capabilities, technologies), with various levels of interdependency among the partners." To make missions with interdependency successful, technologists and system experts need to share information early, before agencies have made concrete plans and binding agreements. This paper provides an overview of possible ways of integrating NASA, ESA, and JAXA work into a conceptual roadmap of life support and environmental monitoring capabilities for future exploration missions. Agencies may have immediate plans as well as long term goals or new ideas that are not part of official policy. But relationships between plans and capabilities may influence the strategies for the best ways to achieve partner goals. Without commitments and an organized program like the International Space Station, requirements for future missions are unclear. Experience from ISS has shown that standards and an early understanding of requirements are an important part of international partnerships. Attempting to integrate systems that were not designed together can create many problems. Several areas have been identified that could be important to discuss and understand early: units of measure, cabin CO2 levels, and the definition and description of fluids like high purity oxygen, potable water and residual biocide, and crew urine and urine pretreat. Each of the partners is exploring different kinds of technologies

  2. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  3. The remote monitoring systems LOVER and RECOVER for international safeguards technical, economic and legal aspects

    International Nuclear Information System (INIS)

    Lauppe, W.D.; Stein, G.; Rezniczek, A.; Stienen, U.

    1983-12-01

    The electronic remote monitoring systems RECOVER and LOVER were developed to comply with the IAEA's tasks concerning international nuclear materials safeguards with the aim of reducing the inspection expenditure and enhancing control effectiveness. The present study on the technical, economic and legal aspects of an application of these systems is intended to show possible implications and provide argumentation aids for discussions on the application of these systems. RECOVER and LOVER offer the possibility of establishing a direct communication path between containment and surveillance system (c/s), instruments at the site of application and a central monitoring station. The demonstration versions of both systems have shown that remote interrogation of data under safeguards-specific boundary conditions (e.g. requirement of tamper safety) will be technically feasible. (orig./HP)

  4. Support and Maintenance of the International Monitoring System network

    Science.gov (United States)

    Pereira, Jose; Bazarragchaa, Sergelen; Kilgour, Owen; Pretorius, Jacques; Werzi, Robert; Beziat, Guillaume; Hamani, Wacel; Mohammad, Walid; Brely, Natalie

    2014-05-01

    The Monitoring Facilities Support Section of the Provisional Technical Secretariat (PTS) has as its main task to ensure optimal support and maintenance of an array of 321 monitoring stations and 16 radionuclide laboratories distributed worldwide. Raw seismic, infrasonic, hydroacoustic and radionuclide data from these facilities constitutes the basic product delivered by the International Monitoring System (IMS). In the process of maintaining such a wide array of stations of different technologies, the Support Section contributes to ensuring station mission capability. Mission capable data availability according to the IMS requirements should be at least 98% annually (no more than 7 days down time per year per waveform stations - 14 continuous for radionuclide stations) for continuous data sending stations. In this presentation, we will present our case regarding our intervention at stations to address equipment supportability and maintainability, as these are particularly large activities requiring the removal of a substantial part of the station equipment and installation of new equipment. The objective is always to plan these activities while minimizing downtime and continuing to meet all IMS requirements, including those of data availability mentioned above. We postulate that these objectives are better achieved by planning and making use of preventive maintenance, as opposed to "run-to-failure" with associated corrective maintenance. We use two recently upgraded Infrasound Stations (IS39 Palau and IS52 BIOT) as a case study and establish a comparison between these results and several other stations where corrective maintenance was performed, to demonstrate our hypothesis.

  5. Remote monitoring for international safeguards

    International Nuclear Information System (INIS)

    Dupree, S.A.; Sonnier, C.S.

    1999-01-01

    Remote monitoring is not a new technology, and its application to safeguards-relevant activities has been examined for a number of years. On behalf of the U.S. Department of Energy and international partners, remote monitoring systems have been emplaced in nuclear facilities and laboratories in various parts of the world. The experience gained from these Geld trials of remote monitoring systems has shown the viability of the concept of using integrated monitoring systems. Although a wide variety of sensors has been used in the remote monitoring field trials conducted to date, the possible range of instrumentation that might be used has scarcely been touched. As the technology becomes widespread, large amounts of data will become available to inspectors responsible for safeguards activities at the sites. Effective use of remote monitoring will require processing, archiving, presenting, and assessing of these data. To provide reasonable efficiency in the application of this technology, data processing should be done in a careful and organized manner. The problem will be not an issue of poring over scant records but of surviving under a deluge of information made possible by modern technology Fortunately, modem technology, which created the problem of the data glut, is available to come to the assistance of those inundated by data. Apart from the technological problems, one of the most important aspects of remote monitoring is the potential constraint related to the transmission of data out of a facility or beyond national borders. Remote monitoring across national borders can be seriously considered only in the context of a comprehensive, transparent, and open implementation regime. (author)

  6. Internal control in the company in order to financial monitoring

    Directory of Open Access Journals (Sweden)

    Osipov A.V.

    2017-04-01

    Full Text Available the article explores the definition of financial monitoring, financial analysis and internal control in aspect to their correlation to fight money laundering and terrorism financing. Internal control is analyzed from the point of view of law, economics and management. The author pays much attention in the article to the work of systems of financial monitoring in organizations.

  7. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  8. ITRAP - an international pilot study on border monitoring systems

    International Nuclear Information System (INIS)

    Beck, P.; Duftschmid, K.E.

    1999-01-01

    The paper describes the design and preliminary results of an extended pilot study of commercially available monitoring systems for the detection of nuclear and other radioactive materials at borders. The study consists of a laboratory test phase and field tests at the Austrian/Hungarian border and the Vienna airport, each for a duration of one year. The results will be used to derive realistic performance requirements for border control systems in view of optimized technical and economic conditions as well as to propose an 'investigation level'. The ITRAP study consists of three phases. In the first phase equipment currently available on the market is subjected to laboratory testing at the Austrian Research Centres Seibersdorf. The instrument categories include hand-held, portable, and fixed-installed equipment. The test criteria defined as minimum requirements have been established together with the manufacturers. The laboratory tests started in May 1998 and will last until end of this year. During the second phase, the field study, equipment passing the laboratory tests will be installed at a major Austrian-Hungarian border crossing (Nickelsdorf) for monitoring of cars, trucks and trains, as well as at the Vienna airport for pedestrians, luggage and cargo. In this phase the results gained from the lab tests about the 'fitness for use' will be verified in practice, in close co-operation with the law enforcement officers at the borders. Also training issues and questions of maintenance and support shall be evaluated. In the third phase, realistic specifications and performance requirements shall be derived with the help of international experts and selected specialists from the users and manufacturers. The results of the field study will focus not only on the technical aspects of monitoring equipment (e.g. detection threshold and rate of false alarms) but also on the operational (e.g. ease of use, reliability, training requirements, field support) and economic

  9. IDEA-system - a new computer based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2005-01-01

    Full text: There is an increasing number of national and international recommendations and guidelines for incorporation monitoring (ICRP Publications, IAEA Safety Reports, ISO Standards, etc.). These recommendations cover different phases of incorporation monitoring and they provide general requirements for the measuring techniques, the monitoring procedures and for the procedures to evaluate intakes and doses from the monitoring results. There is, however, still a strong need for giving guidance to the dosimetrists on how to apply all the regulations properly. Thus, the EU project IDEAS was launched in order to provide general guidelines for the assessment of internal dose from incorporation monitoring data. These guidelines have recently been discussed in a virtual workshop on the internet (www.ideas-workshop.de) and they are being considered by ICRP for possible adoption in the near future. Recently, in the Karlsruhe Research Centre, a computer-based expert system has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for incorporation monitoring and internal dosimetry. The expert system gives guidance to the user with respect to: planning of monitoring (estimation of potential exposures, decision on the requirements of monitoring, definition of optimum measuring techniques and monitoring intervals); performing routine and special monitoring and evaluation of primary monitoring results. The evaluation of primary monitoring results is done according to the IDEAS guidelines in a threestage procedure according to the expected level of exposure (E = committed effective dose): standard evaluation with default or site specific parameter values (E 6 mSv). With these well-defined procedures the expert system follows the aim, that all recommendations and guidelines are applied properly and thus: internal exposures of more than 1 mSv are very likely to be detected in all situations; the results in terms of committed effective

  10. Partial monitoring system Radioactivity of the Environment, 2006

    International Nuclear Information System (INIS)

    Melicherova, T.

    2007-01-01

    In this report the Partial monitoring system 'Radioactivity of the Environment' for the year 2006 is presented. International co-operation of the Slovak Hydrometeorological Institute in the Partial monitoring system 'Radioactivity of the Environment' of the Slovak Republic, international co-operation as well as financial data are reviewed

  11. Software requirements elicitation to support internal monitoring of quality assurance system for higher education in Indonesia

    Science.gov (United States)

    Amalia, A.; Gunawan, D.; Hardi, S. M.; Rachmawati, D.

    2018-02-01

    The Internal Quality Assurance System (in Indonesian: SPMI (Sistem Penjaminan Mutu Internal) is a systemic activity of quality assurance of higher education in Indonesia. SPMI should be done by all higher education or universities in Indonesia based on the Regulation of the Minister of Research, Technology and Higher Education of the Republic of Indonesia Number 62 of 2016. Implementation of SPMI must refer to the principle of SPMI that is independent, standardize, accurate, well planned and sustainable, documented and systematic. To assist the SPMI cycle properly, universities need a supporting software to monitor all the activities of SPMI. But in reality, many universities are not optimal in building this SPMI monitoring system. One of the obstacles is the determination of system requirements in support of SPMI principles is difficult to achieve. In this paper, we observe the initial phase of the engineering requirements elicitation. Unlike other methods that collect system requirements from users and stakeholders, we find the system requirements of the SPMI principles from SPMI guideline book. The result of this paper can be used as a choice in determining SPMI software requirements. This paper can also be used by developers and users to understand the scenario of SPMI so that could overcome the problems of understanding between this two parties.

  12. 49 CFR 192.477 - Internal corrosion control: Monitoring.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Monitoring. 192.477... Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons... internal corrosion. Each coupon or other means of monitoring internal corrosion must be checked two times...

  13. ITRAP - International laboratory and field test site exercise for radiation detection instruments and monitoring systems at border crossings

    International Nuclear Information System (INIS)

    Beck, P.; Schmitzer, C.; Duftschmid, K.E.; Arlt, R.

    2001-01-01

    Illicit trafficking in nuclear materials has become more and more a problem, due to the circulation of a high number of radioactive sources and the big amount of nuclear material. The IAEA database counts at present more than 300 verified cases. The endangering cased thereby ranges from possible health defect for the publication to terrorists activities and production of nuclear weapons. In addition to the primary criminal reasons the illegal disposal of radioactive sources as salvage, scrap and others show a further problem, which has lead to severe accidents and lethal effects in the past (e.g. Goiana, Mexico). Some countries have already under taken countermeasures (e.g. Monitoring at the Finnish-Russian and German- Polish border, border monitoring in Italy). The International Atomic Energy Agency (IAEA) has reacted on this actual problem by setting up a new program to fight against nuclear criminality and has suggested a pilot study for the practical test of border monitoring systems. Co-ordinated by the Federal Ministry of Economy and Labour the Austrian Government financed the pilot study ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the Austrian Research Centers Seibersdorf (ARCS). Aim of the study was to work out the technical requirements and the practicability of an useful monitoring system at border crossings. The results of the study will be offered by the IAEA to the member states as international recommendations for border monitoring systems

  14. Update on Monitoring Technologies for International Safeguards and Fissile Material Verification

    International Nuclear Information System (INIS)

    Croessmann, C. Dennis; Glidewell, Don D.; Mangan, Dennis L.; Smathers, Douglas C.

    1999-01-01

    Monitoring technologies are playing an increasingly important part in international safeguards and fissile material verification. The developments reduce the time an inspector must spend at a site while assuring continuity of knowledge. Monitoring technologies' continued development has produced new seal systems and integrated video surveillance advances under consideration for Trilateral Initiative use. This paper will present recent developments for monitoring systems at Embalse, Argentina, VNHEF, Sarov, Russian, and Savannah River Site, Aiken, South Carolina

  15. Banking system and financial monitoring in Russian Federation

    Directory of Open Access Journals (Sweden)

    Osipov A.V.

    2017-04-01

    Full Text Available the article explores the definition of banking system and financial monitoring. Attention is emphasizes on role of internal control in aspect their relation to contraction to money laundering and financing of terrorism/ Internal control is analises from the point of view law, economic and management. Basic attention in the article author emphasizes on work of systems of financial monitoring in organizations.

  16. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  17. Draft I.E.C. standard for monitoring PWR internal structures; Projet de norme C.E.I. pour la surveillance des structures internes des REP

    Energy Technology Data Exchange (ETDEWEB)

    Trenty, A.

    1994-06-01

    EDF has proposed to the International Electrotechnical Commission a draft standard for monitoring the vessel internal structures of PWRs. The standard applies to systems used for monitoring the vibratory behavior of the internal structures of PWRs (core barrel, thermal shield, fuel assemblies) on the basis of neutron fluctuations observed outside the vessel as well as of vessel vibrations. It covers the systems characteristics and the monitoring procedures. It should facilitate standardization of monitoring and comparisons on an international level. This paper presents the main features of the draft standard: -principles of measurement: correlation between movements of internals and ex core neutron noise on the one hand, forced vibrations of the vessel on the other hand; -sampling and conditioning of the signals; -monitoring equipment and in particular spectral analysis device; -functions of the monitoring software used for spectral analysis, peak detection and calculation of structure displacement; -studies preliminary to setting up the monitoring (calculation of internal vibratory modes, defect simulation on mockup, qualification on reactor during hot test...); -monitoring procedures (periodicity of analysis and what to do in case of anomaly); -documentation necessary to the monitoring. A diagnostic procedure is given as an example. The draft standard, written in 1994, will be presented in Frankfurt (Germany) in February 1995. (author). 1 annexe.

  18. Verbal monitoring in Parkinson’s disease: A comparison between internal and external monitoring

    Science.gov (United States)

    Mertens, Jolien; Mariën, Peter; Santens, Patrick; Pickut, Barbara A.; Hartsuiker, Robert J.

    2017-01-01

    Patients with Parkinson’s disease (PD) display a variety of impairments in motor and non-motor language processes; speech is decreased on motor aspects such as amplitude, prosody and speed and on linguistic aspects including grammar and fluency. Here we investigated whether verbal monitoring is impaired and what the relative contributions of the internal and external monitoring route are on verbal monitoring in patients with PD relative to controls. Furthermore, the data were used to investigate whether internal monitoring performance could be predicted by internal speech perception tasks, as perception based monitoring theories assume. Performance of 18 patients with Parkinson’s disease was measured on two cognitive performance tasks and a battery of 11 linguistic tasks, including tasks that measured performance on internal and external monitoring. Results were compared with those of 16 age-matched healthy controls. PD patients and controls generally performed similarly on the linguistic and monitoring measures. However, we observed qualitative differences in the effects of noise masking on monitoring and disfluencies and in the extent to which the linguistic tasks predicted monitoring behavior. We suggest that the patients differ from healthy subjects in their recruitment of monitoring channels. PMID:28832595

  19. The Global Communication Infrastructure of the International Monitoring System

    Science.gov (United States)

    Lastowka, L.; Gray, A.; Anichenko, A.

    2007-05-01

    The Global Communications Infrastructure (GCI) employs 6 satellites in various frequency bands distributed around the globe. Communications with the PTS (Provisional Technical Secretariat) in Vienna, Austria are achieved through VSAT technologies, international leased data circuits and Virtual Private Network (VPN) connections over the Internet. To date, 210 independent VSAT circuits have been connected to Vienna as well as special circuits connecting to the Antarctic and to independent sub-networks. Data volumes from all technologies currently reach 8 Gigabytes per day. The first level of support and a 24/7 help desk remains with the GCI contractor, but performance is monitored actively by the PTS/GCI operations team. GCI operations are being progressively introduced into the PTS operations centre. An Operations centre fully integrated with the GCI segment of the IMS network will ensure a more focused response to incidents and will maximize the availability of the IMS network. Existing trouble tickets systems are being merged to ensure the commission manages GCI incidents in the context of the IMS as a whole. A focus on a single source of data for GCI network performance has enabled reporting systems to be developed which allow for improved and automated reports. The contracted availability for each individual virtual circuit is 99.5% and this performance is regularly reviewed on a monthly basis

  20. International Symposium on Monitoring Behavior and Supervisory Control

    CERN Document Server

    Johannsen, Gunnar

    1976-01-01

    This book includes all papers presented at the International Symposium on Monitoring Behavior and Supervisory Control held at Berchtesgaden, Federal Republic of Germany, March 8-12, 1976. The Symposium was sponsored by the Scientific Affairs Division of the North Atlantic Treaty Organization, Brussels, and the government of the Federal Republic of Germany, Bonn. We believe the book constitutes an important and timely status report on monitoring behavior and supervisory control by human operators of complex man-machine systems in which the computer is sharing key functions with the man. These systems include aircraft and other vehicles, nuclear and more conventional power plants, and processes for the manu­ facture of chemicals, petroleum, and discrete parts. By "monitoring" we mean the systematic observation by a human operator of mul tiple sources of information, e. g. , ranging from integrated display consoles to disparate "live situations". The monitor's purpose is to determine whether operations are norm...

  1. Survey of environment related monitoring programmes of international organizations and their contribution to international monitoring programmes

    International Nuclear Information System (INIS)

    1986-12-01

    The report is a summary of environment-related monitoring programmes of international governmental organizations and their contribution to international monitoring programmes. it presents the situation as of November 1986: This survey has been prepared by a consultant for the Secretariat as a background document for the second meeting of the Environment Experts, Economic Summit in Munich, November 1986. It serves information purposes only. No claim for completeness is intended. This report may also prove to be helpful for administrators and the scientific community as regards gaining knowledge on present arrangements, approaches and environmental activities in the framework of international organizations. In this light, the present report could facilitate communication and progress in solving pressing environmental problems on the international level. (orig.)

  2. Monitoring the Microgravity Environment Quality On-board the International Space Station Using Soft Computing Techniques. Part 2; Preliminary System Performance Results

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.; Weiss, Daniel S.

    2002-01-01

    This paper presents the preliminary performance results of the artificial intelligence monitoring system in full operational mode using near real time acceleration data downlinked from the International Space Station. Preliminary microgravity environment characterization analysis result for the International Space Station (Increment-2), using the monitoring system is presented. Also, comparison between the system predicted performance based on ground test data for the US laboratory "Destiny" module and actual on-orbit performance, using measured acceleration data from the U.S. laboratory module of the International Space Station is presented. Finally, preliminary on-orbit disturbance magnitude levels are presented for the Experiment of Physics of Colloids in Space, which are compared with on ground test data. The ground test data for the Experiment of Physics of Colloids in Space were acquired from the Microgravity Emission Laboratory, located at the NASA Glenn Research Center, Cleveland, Ohio. The artificial intelligence was developed by the NASA Glenn Principal Investigator Microgravity Services Project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment of time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a dynamic graphical display, implemented in Java, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, structural modes, etc., and decide whether or not to run their experiments, whenever that is an option, based on the acceleration magnitude and frequency sensitivity associated with that experiment. This monitoring system detects primarily the vibratory disturbance sources. The system has built-in capability to detect both known

  3. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  4. Internal quality control program for individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia L.P.; Moura Junior, Jose; Patrao, Karla C.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: claudia@ird.gov.br; moura@ird.gov.br; karla@ird.gov.br

    2007-07-01

    With a focus on continuous improvement, since 2002, a special internal procedure for following and checking the performance of our individual monitoring services has been implemented. A fictitious installation, named 'Fantasma' has been created, initially, with 4 film badges and 7 thermoluminescent dosimetric ring users. Since 2005, this quality control program includes also the albedo neutron individual monitoring service. Monthly, the 'Fantasma' test monitors are irradiated by traceable Cs-137 and Am-Be sources. The calibration quantities are: the photon dose equivalent (H{sub x}) for the photographic individual monitor, the maximum dose equivalent (MADE) for the albedo neutron individual monitor and the personal dose equivalent at 0.07 mm depth (H{sub p}(0.07)) for ring monitor. Up to now, all results show compliance with the specific trumpet curves acceptance limits. Once, a small sub-evaluation tendency has been noted and this information was used to improve the film system. For the photographic film system, the evaluated value to reference dose ratios range from 0.71 to 1.12, with a mean value of 0.91 {+-} 0.12. For the ring system, the ratio ranges from 0.69 to 1.40, with a mean value of 1.02 {+-} 0.07. For the neutron system, which presents intrinsic larger uncertainties, the ratio ranged from 0.67 to 1.88, with mean value of 1.16 {+-} 0.27. (author)

  5. Airborne anthropogenic radioactivity measurements from an international radionuclide monitoring system

    International Nuclear Information System (INIS)

    Mason, L.R.; Bohner, J.D.; Williams, D.L.

    1998-01-01

    Anthropogenic radioactivity is being measured in near-real time by an international monitoring system designed to verify the Comprehensive Nuclear Test Ban Treaty. Airborne radioactivity measurements are conducted in-situ by stations that are linked to a central data processing and analysis facility. Aerosols are separated by high-volume air sampling with high-efficiency particulate filters. Radio-xenon is separated from other gases through cryogenic methods. Gamma-spectrometry is performed by high purity germanium detectors and the raw spectral data is immediately transmitted to the central facility via Internet, satellite, or modem. These highly sensitive sensors, combined with the automated data processing at the central facility, result in a system capable of measuring environmental radioactivity on the microbecquerel scale where the data is available to scientists within minutes of the field measurement. During the past year, anthropogenic radioactivity has been measured at approximately half of the stations in the current network. Sources of these measured radionuclides include nuclear power plant emissions, Chernobyl resuspension, and isotope production facilities. The ability to thoroughly characterize site-specific radionuclides, which contribute to the radioactivity of the ambient environment, will be necessary to reduce the number of false positive events. This is especially true of anthropogenic radionuclides that could lead to ambiguous analysis. (author)

  6. Harmonisation (legal, dosimetric, quality aspects) of individual monitoring, and integration of monitoring for external and internal exposures (EURADOS working group)

    International Nuclear Information System (INIS)

    Lopez, M.A.; Currivan, L.; Falk, R.; Olko, P.; Wernli, C.; Castellani, C.M.; Dijk, J.W.E. van

    2003-01-01

    The EURADOS Working Group II on 'Harmonisation of individual monitoring' consists of experts from almost all EU Member States and Newly Associated States (NAS), involved in tasks related to the assessment of doses for internal and external radiation. The final objective is to achieve harmonisation in individual monitoring for occupational exposures. Sub-group 2 activities are focused on investigating how the results from personal dosemeters for external radiation and workplace monitoring and from monitoring for internal exposure can be combined into a complete and consistent system of individual monitoring. Three questionnaires were prepared, covering Individual monitoring of external radiation (Questionnaire 1), 'Internal exposure' (Questionnaire 2) and 'Natural sources of radiation at workplace' (Questionnaire 3). With the agreement of a 'contact-person' selected in each country, the distribution of the three EURADOS 2002 questionnaires was carried out by e-mail among the dosimetry facilities of 28 European countries. The preliminary results of these actions are presented here. (author)

  7. IDEA system - a new computer-based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2007-01-01

    Recently, at the Karlsruhe Research Centre, a computer-based expert system, Internal Dose Equivalent Assessment System (IDEA System), has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for internal dosimetry. The expert system gives guidance to the user with respect to: (a) planning of monitoring, (b) performing routine and special monitoring, and (c) evaluation of primary monitoring results. The evaluation is done according to the IDEA System guidelines (Doerfel, H. et al., General guidelines for the estimation of committed effective dose from incorporation monitoring data. Research Report FZKA 7243, Research Center Karlsruhe, Karlsruhe (2006). ISSN 0947-8260.) in a three-stage procedure according to the expected level of exposure. At the first level the evaluation is performed with default or site-specific parameter values, at the second level case-specific parameter values are applied and at the third level a special evaluation is performed with individual adjustment of model parameter values. With these well-defined procedures the expert system follows the aim, in which all recommendations and guidelines are applied properly and the results in terms of committed effective and organ doses are close to the best estimate. (author)

  8. The Wettzell System Monitoring Concept and First Realizations

    Science.gov (United States)

    Ettl, Martin; Neidhardt, Alexander; Muehlbauer, Matthias; Ploetz, Christian; Beaudoin, Christopher

    2010-01-01

    Automated monitoring of operational system parameters for the geodetic space techniques is becoming more important in order to improve the geodetic data and to ensure the safety and stability of automatic and remote-controlled observations. Therefore, the Wettzell group has developed the system monitoring software, SysMon, which is based on a reliable, remotely-controllable hardware/software realization. A multi-layered data logging system based on a fanless, robust industrial PC with an internal database system is used to collect data from several external, serial, bus, or PCI-based sensors. The internal communication is realized with Remote Procedure Calls (RPC) and uses generative programming with the interface software generator idl2rpc.pl developed at Wettzell. Each data monitoring stream can be configured individually via configuration files to define the logging rates or analog-digital-conversion parameters. First realizations are currently installed at the new laser ranging system at Wettzell to address safety issues and at the VLBI station O Higgins as a meteorological data logger. The system monitoring concept should be realized for the Wettzell radio telescope in the near future.

  9. Organization of internal contamination monitoring

    International Nuclear Information System (INIS)

    Badreddine, A.

    1986-07-01

    The nuclear energy takes a big part in the world's energy production. The nuclear techniques are used in most fields of life. Nevertheless the use of radioactive materials may cause prejudice to human beings by radiation contamination. The International Commission on Radiological Protection gives the general rules and regulations to avoid this danger. In the publication No. 30, the ICRP gives a metabolic model for the respiratory system and values of Annual Limit of Intake. The ALI for inhalation supposes a standard AMAD (Activity Median Aerodynamic Diameter) of 1 um. We have measured the AMAD in a laboratory under different conditions of functioning in order to show its variation. Then we have analysed the effect of this variation on the internal contamination monitoring. Thus we have calculated the Effective Committed Dose (ECD), the ALI, then the Derived Investigation Level (DIL) for different values of AMAD for Whole-Body Counting (WBC)

  10. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  11. On-line internal corrosion monitoring and data management for remote pipelines: a technology update

    Energy Technology Data Exchange (ETDEWEB)

    Wold, Kjell; Stoen, Roar; Jenssen, Hallgeir [Roxar Flow Measurement AS, Stavanger (Norway); Carvalho, Anna Maria [Roxar do Brasil Ltda., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Internal corrosion monitoring of remote pipelines can be costly and demanding on resources. Online and non-intrusive monitoring directly on the pipe wall can improve the quality of measurements, make installation more convenient and allow more efficient communication of data. The purpose of this paper is to describe a non-intrusive technology, and show examples on field installations of the system. Furthermore, the non-intrusive technology data can be stored, interpreted and combined with conventional (intrusive) system information, in order to get a full picture of internal corrosion profile, corrosion rate and trends regarding the pipeline being monitored. (author)

  12. Safeguards equipment of the future integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    Becoming aware of the significant events of the past four years and their effect on the expectations to international safeguards, it is necessary to reflect on which direction the development of nuclear safeguards in a new era needs to take and the implications. The lime proven monitoring techniques, based on quantitative factor's and demonstrated universal application, have shown their merit. However, the new expectations suggest a possibility that a future IAEA safeguards system could rely more heavily on the value of a comprehensive, transparent and open implementation regime. Within such a regime, the associated measures need to be determined and technological support identified. This paper will identify the proven techniques which, with appropriate implementation support, could most quickly make available additional measures for a comprehensive, transparent and open implementation regime. In particular, it will examine the future of Integrated Monitoring Systems and Remote Monitoring in international safeguards, including technical and other related factors

  13. Impact of the internal contamination monitoring for national and international regulations

    International Nuclear Information System (INIS)

    Gaburo, J.C.; Sordi, G.M.

    1996-01-01

    An evaluation of the internal radiation dose received by workers between 1984 and 1994 was performed, after a brief description of IPEN facility. The National and International Recommendation aims to reduce the workers' doses below 1/10 of the annual limits. The routine monitoring should be eliminated, if the individual annual dose is below 3/10 of the annual limits. In this case, only the operational monitoring should be maintained. In principle, the concept of restricted area should be reviewed, because, according to Publication 26 of ICRP, 1977, it should be a supervised area instead. The new concept of restricted area recommended by the Publication 60, ICRP 1991, should be adjusted accordingly. Thus, the classification used by the Commission-controlled areas and supervised areas will be with the foreseeable dose and not with the actual dose. When the individual annual dose is kept below 1/10 of the annual limits, the routine monitoring is not necessary, and only operational monitoring is needed. Finally, the future possible activities of the Individual Internal Dosimetry Laboratory at IPEN are discussed, after the elimination of individual monitoring. (authors). 8 refs

  14. Evaluation of sensitivity evaluation of a contamination monitor for use in monitoring of internal exposure of workers in nuclear medicine

    International Nuclear Information System (INIS)

    Dantas, Bernando Maranhao; Assis, Janima Cruz de; Oliveira, Salomao Marques de; Dantas, Ana Leticia Almeida

    2014-01-01

    In practice of nuclear medicine, expert personnel routinely handle radiopharmaceuticals for diagnosis and radiotherapy. The control of intakes of radionuclides by workers can be performed through internal dosimetry techniques, as an integral part of the radiation protection program of the installation. The use of radiopharmaceuticals for diagnostic and therapeutic purposes in vivo and in vitro in Brazil is regulated by CNEN-NE Standards and 3:05 CNEN-NN 3.01. The International Atomic Energy Agency (IAEA) recommends the establishment of an internal monitoring program on workers, especially those subject to possible exposure to annual effective doses greater than 1 mSv. Note that, currently, in Brazil, are not available qualified laboratories to provide internal monitoring services in all regions in the country, if it were applied by CNEN, the requirement for internal monitoring of workers. This paper presents the development of a simple and low-cost methodology for in vivo monitoring of 131 I in the thyroid. The proposed methodology is the use of portable monitor of surface contamination, equipment available and routinely used in all nuclear medicine services in Brazil. The monitor is calibrated with neck-thyroid simulator developed at the Laboratory of In Vivo Monitoring of IRD/CNEN-RJ. The equipment tested is suitable for application in in vivo occupational monitoring thyroid. This conclusion is based on the fact that the detection system has sufficient sensitivity for monitoring up to seven days after the incorporation of the radionuclide and guarantees 131 I detection in values that result in effective doses below 1 mSv for the exposure scenarios adopted

  15. Monitoring programmes for internal exposure: designing criteria

    International Nuclear Information System (INIS)

    Rojo, Ana M.; Gomez Parada, Ines.

    2007-01-01

    The purpose of this document is to offer guidance for the decision whether a monitoring programme is required and how it should be designed. It can be also used as a tool for making the standing programmes consistent with the most recent publications on internal dosimetry, such as ISO 20553 'Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material', specific publications of the IAEA and ICRP, and including the conclusions of the OMINEX Project ('Optimisation of Monitoring for Internal Exposures') and IDEAS Project. It is established that the general purpose of the monitoring is verify that each worker is protected adequately against risks from radionuclide intakes and document that the protection complies with legal requirements. The criteria for a particular monitoring programme designing is based on the magnitude of the probable intake and the possibility of detecting a significant event when it occurs. So, the risk assessment for each work process must be evaluated and each worker is classified accordingly. This classification implies the acceptance of reference effective dose values (1 y 6 mSv/y ). (author) [es

  16. Storage monitoring systems for the year 2000

    International Nuclear Information System (INIS)

    Nilsen, C.; Pollock, R.

    1997-01-01

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000

  17. Tuning permissiveness of active safety monitors for autonomous systems

    OpenAIRE

    Masson , Lola; Guiochet , Jérémie; Waeselynck , Hélène; Cabrera , Kalou; Cassel , Sofia; Törngren , Martin

    2018-01-01

    International audience; Robots and autonomous systems have become a part of our everyday life, therefore guaranteeing their safety is crucial.Among the possible ways to do so, monitoring is widely used, but few methods exist to systematically generate safety rules to implement such monitors. Particularly, building safety monitors that do not constrain excessively the system's ability to perform its tasks is necessary as those systems operate with few human interventions.We propose in this pap...

  18. Data Analysis of Seismic Sequence in Central Italy in 2016 using CTBTO- International Monitoring System

    Science.gov (United States)

    Mumladze, Tea; Wang, Haijun; Graham, Gerhard

    2017-04-01

    The seismic network that forms the International Monitoring System (IMS) of the Comprehensive Nuclear-test-ban Treaty Organization (CTBTO) will ultimately consist of 170 seismic stations (50 primary and 120 auxiliary) in 76 countries around the world. The Network is still under the development, but currently more than 80% of the network is in operation. The objective of seismic monitoring is to detect and locate underground nuclear explosions. However, the data from the IMS also can be widely used for scientific and civil purposes. In this study we present the results of data analysis of the seismic sequence in 2016 in Central Italy. Several hundred earthquakes were recorded for this sequence by the seismic stations of the IMS. All events were accurately located the analysts of the International Data Centre (IDC) of the CTBTO. In this study we will present the epicentral and magnitude distribution, station recordings and teleseismic phases as obtained from the Reviewed Event Bulletin (REB). We will also present a comparison of the database of the IDC with the databases of the European-Mediterranean Seismological Centre (EMSC) and U.S. Geological Survey (USGS). Present work shows that IMS data can be used for earthquake sequence analyses and can play an important role in seismological research.

  19. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  20. Real Time Fire Reconnaissance Satellite Monitoring System Failure Model

    Science.gov (United States)

    Nino Prieto, Omar Ariosto; Colmenares Guillen, Luis Enrique

    2013-09-01

    In this paper the Real Time Fire Reconnaissance Satellite Monitoring System is presented. This architecture is a legacy of the Detection System for Real-Time Physical Variables which is undergoing a patent process in Mexico. The methodologies for this design are the Structured Analysis for Real Time (SA- RT) [8], and the software is carried out by LACATRE (Langage d'aide à la Conception d'Application multitâche Temps Réel) [9,10] Real Time formal language. The system failures model is analyzed and the proposal is based on the formal language for the design of critical systems and Risk Assessment; AltaRica. This formal architecture uses satellites as input sensors and it was adapted from the original model which is a design pattern for physical variation detection in Real Time. The original design, whose task is to monitor events such as natural disasters and health related applications, or actual sickness monitoring and prevention, as the Real Time Diabetes Monitoring System, among others. Some related work has been presented on the Mexican Space Agency (AEM) Creation and Consultation Forums (2010-2011), and throughout the International Mexican Aerospace Science and Technology Society (SOMECYTA) international congress held in San Luis Potosí, México (2012). This Architecture will allow a Real Time Fire Satellite Monitoring, which will reduce the damage and danger caused by fires which consumes the forests and tropical forests of Mexico. This new proposal, permits having a new system that impacts on disaster prevention, by combining national and international technologies and cooperation for the benefit of humankind.

  1. Remote monitoring of VRLA batteries for telecommunications systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsujikawa, Tomonobu; Matsushima, Toshio [NTT Facilities Inc., G.H.Y. Building, 2-13-1 Kita-Otsuka, Toshima-ku, Tokyo 170-0004 (Japan)

    2007-05-25

    This paper describes a remote monitoring system that can be set up in an operating center to monitor the state of valve regulated lead acid batteries (VRLA) used as a backup power supply for telecommunications. This system has a battery voltage monitoring function, a lifetime prediction function based on ambient temperature, and a discharge circuit diagnosis function. In addition, the system can be equipped with an internal resistance measurement function and an electrolyte leakage detection function to further insure power-supply reliability. Various states of batteries observed with the system are transmitted to the remote operating center by a remote monitoring function. This function enables obtaining immediate information about the condition of batteries and helps to avoid unexpected failures. (author)

  2. Modernization of WWER-1000 radiation monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T [General Atomics, San Diego, CA (United States)

    1996-12-31

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs.

  3. Modernization of WWER-1000 radiation monitoring systems

    International Nuclear Information System (INIS)

    Smith, T.

    1995-01-01

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs

  4. Remote supervision of GIS monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)

    2007-07-01

    Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.

  5. Integrating existing radiation monitors into a microprocessor-based display system

    International Nuclear Information System (INIS)

    Kalita, R, S.; Bartucci, C.M.; Mason, R.G.; Greaves, C.

    1992-01-01

    Plantwide digital radiation monitoring systems (RMSs) have been generally installed as part of the original design for newer nuclear reactors. For older plants, area and process radiation monitors were either analog or a combination of analog and digital but were not part of an integrated system design. At some plants, individual monitors have been replaced or modified, resulting in a rainbow of different monitors and vendors being represented at the plant. Usually at some point, consideration is given to replacing these monitors with a state-of-the-art RMS to improve overall reliability and achieve the benefits of sound human factors engineering. This can be a very costly project in terms of expenditures for engineering, equipment, construction, startup, and time. When human engineering deficiencies (HEDs) became an issue at Zion station, Commonwealth Edison elected to install a computer-based radiation monitoring display system (RMDS) that would interface existing raidation monitors. After reviewing the existing as-built RMS configuration and internal circuits of the various monitors, it was concluded that a microprocessor-based RMDS could be successfully designed and installed that would solve the HEDs and would tie the older analog channels into a system configuration. Although in many cases, internal modifications were made to existing RMS monitors, the RMDS upgrade allowed the existing RMS monitors to retain their original functionality and location

  6. Indirect monitoring of internal exposure for actinides

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro G, C.J.; Barreto F, J.; Todo A, A. [Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN, Av. Professor Lineu Prestes No. 2242, Zip code 05508-000, Sao Paulo (Brazil)

    2006-07-01

    The procedure used to the assessment of internal exposure of workers involved with dismantling lightning rods and radioactive smoke detectors is described. Due to the presence of the sources of {sup 241} Am in these devices, a monitoring program to the workers have been implemented. This paper presents an analytical method for the separation and analysis of plutonium (Pu) and americium (Am) in urine samples using solid-phase extraction chromatography and alpha spectrometry. The mean recovery obtained with this technique is about 80% and the detection limit for 24 h urine sample range between 0.6 mBqL{sup -1} and 1.0 mBqL{sup -1}. The assessment of intakes and internal doses are performed following ICRP Publication 78 recommendations and appropriated biokinetic models (ICRP, 1997). Assumptions have been made for routine monitoring of these workers and it is also discussed the establishment of the internal monitoring program using the results of alpha measurements. (Author)

  7. Indirect monitoring of internal exposure for actinides

    International Nuclear Information System (INIS)

    Carneiro G, C.J.; Barreto F, J.; Todo A, A.

    2006-01-01

    The procedure used to the assessment of internal exposure of workers involved with dismantling lightning rods and radioactive smoke detectors is described. Due to the presence of the sources of 241 Am in these devices, a monitoring program to the workers have been implemented. This paper presents an analytical method for the separation and analysis of plutonium (Pu) and americium (Am) in urine samples using solid-phase extraction chromatography and alpha spectrometry. The mean recovery obtained with this technique is about 80% and the detection limit for 24 h urine sample range between 0.6 mBqL -1 and 1.0 mBqL -1 . The assessment of intakes and internal doses are performed following ICRP Publication 78 recommendations and appropriated biokinetic models (ICRP, 1997). Assumptions have been made for routine monitoring of these workers and it is also discussed the establishment of the internal monitoring program using the results of alpha measurements. (Author)

  8. Development of Web based system for individual internal monitoring programme; Desenvolvimento de um sistema baseado na Web para suporte ao programa de monitoracao individual interna do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Vanessa Rogeria de

    2007-07-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  9. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  10. Radiation internal exposure measurements archiving system (REMAS)

    International Nuclear Information System (INIS)

    Bitar, A.; Maghrabi, M.

    2013-01-01

    This paper describes a personal-computer-based software, REMAS, which helps users to estimate intake activity and resulting internal doses for all radionuclides existing in (International Commission on Radiological Protection) ICRP 78 and other important elements. In addition to its use in internal dose calculations, it facilitates management of data of monitored persons who are occupationally exposed to unsealed radioactive substances. Furthermore, REMAS offers the possibility to generate different reports of results. The program is suitable for laboratories working in the field of assessment of occupational intake and also for users of radioactive material who are routinely monitored. REMAS, which is bilingual program (English and Arabic), was built with GUI environment and was developed using Microsoft FoxPro. It runs on Microsoft Windows XP operating systems. (authors)

  11. Maintenance and Logistics Support for the International Monitoring System Network of the CTBTO

    Science.gov (United States)

    Haslinger, F.; Brely, N.; Akrawy, M.

    2007-05-01

    The global network of the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), once completed, will consist of 321 monitoring facilities of four different technologies: hydroacoustic, seismic, infrasonic, and radionuclide. As of today, about 65% of the installations are completed and contribute data to the products issued by the International Data Centre (IDC) of the CTBTO. In order to accomplish the task to reliably collect evidence for any potential nuclear test explosion anywhere on the planet, all stations are required to perform to very high data availability requirements (at least 98% data availability over a 12-month period). To enable reaching this requirement, a three-layer concept has been developed to allow efficient support of the IMS stations: Operations, Maintenance and Logistics, and Engineering. Within this concept Maintenance and Logistics provide second level support of the stations, whereby problems arising at the station are assigned through the IMS ticket system to Maintenance if they cannot be resolved on the Operations level. Maintenance will then activate the required resources to appropriately address and ultimately resolve the problem. These resources may be equipment support contracts, other third party contracts, or the dispatch of a maintenance team. Engineering Support will be activated if the problem requires redesign of the station or after catastrophic failures when a total rebuild of a station may be necessary. In this model, Logistics Support is responsible for parts replenishment and support contract management. Logistics Support also collects and analyzes relevant failure mode and effect information, develops supportability models, and has the responsibility for document management, obsolescence, risk & quality, and configuration management, which are key elements for efficient station support. Maintenance Support in addition is responsible for maintenance strategies, for

  12. Expert Water Quality Panel Review of Responses to the NASA Request for Information for the International Space Station On-Board Environmental Monitoring System

    Science.gov (United States)

    Fishman, Julianna L.; Mudgett, Paul D.; Packham, Nigel J.; Schultz, John R.; Straub, John E., II

    2005-01-01

    On August 9, 2003, NASA, with the cooperative support of the Vehicle Office of the International Space Station Program, the Advanced Human Support Technology Program, and the Johnson Space Center Habitability and Environmental Factors Office released a Request for Information, or RFI, to identify next-generation environmental monitoring systems that have demonstrated ability or the potential to meet defined requirements for monitoring air and water quality onboard the International Space Station. This report summarizes the review and analysis of the proposed solutions submitted to meet the water quality monitoring requirements. Proposals were to improve upon the functionality of the existing Space Station Total Organic Carbon Analyzer (TOCA) and monitor additional contaminants in water samples. The TOCA is responsible for in-flight measurement of total organic carbon, total inorganic carbon, total carbon, pH, and conductivity in the Space Station potable water supplies. The current TOCA requires hazardous reagents to accomplish the carbon analyses. NASA is using the request for information process to investigate new technologies that may improve upon existing capabilities, as well as reduce or eliminate the need for hazardous reagents. Ideally, a replacement for the TOCA would be deployed in conjunction with the delivery of the Node 3 water recovery system currently scheduled for November 2007.

  13. Adaptive and Online Health Monitoring System for Autonomous Aircraft

    OpenAIRE

    Mokhtar, Maizura; Zapatel-Bayo, Sergio Z.; Hussein, Saed; Howe, Joe M.

    2012-01-01

    Good situation awareness is one of the key attributes required to maintain safe flight, especially for an Unmanned Aerial System (UAS). Good situation awareness can be achieved by incorporating an Adaptive Health Monitoring System (AHMS) to the aircraft. The AHMS monitors the flight outcome or flight behaviours of the aircraft based on its external environmental conditions and the behaviour of its internal systems. The AHMS does this by associating a health value to the aircraft's behaviour b...

  14. Applications for cyber security - System and application monitoring

    International Nuclear Information System (INIS)

    Marron, J. E.

    2006-01-01

    Standard network security measures are adequate for defense against external attacks. However, many experts agree that the greater threat is from internal sources. Insiders with malicious intentions can change controller instructions, change alarm thresholds, and issue commands to equipment which can damage equipment and compromise control system integrity. In addition to strict physical security the state of the system must be continually monitored. System and application monitoring goes beyond the capabilities of network security appliances. It will include active processes, operating system services, files, network adapters and IP addresses. The generation of alarms is a crucial feature of system and application monitoring. The alarms should be integrated to avoid the burden on operators of checking multiple locations for security violations. Tools for system and application monitoring include commercial software, free software, and ad-hoc tools that can be easily created. System and application monitoring is part of a 'defense-in-depth' approach to a control network security plan. Layered security measures prevent an individual security measure failure from being exploited into a successful security breach. Alarming of individual failures is essential for rapid isolation and correction of single failures. System and application monitoring is the innermost layer of this defense strategy. (authors)

  15. Vulnerability analysis on a VPN for a remote monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kim, Jong Soo; Park, Il Jin; Min, Kyung Sik; Choi, Young Myung [KAERI, Taejon (Korea, Republic of)

    2004-08-01

    14 Pressurized Water Reactors(PWR) in Korea use a Remote Monitoring System(RMS), which have been in Korea Since 1998. A memorandum of understanding on remote monitoring, based on enhanced cooperation on PWRs, was signed at the 10th safeguards review meeting in October 2001 between the International Atomic Energy Agency(IAEA) and Ministry Of Science and Technology(MOST). Thereafter, all PWR power plants applied for remote monitoring systems. However, the existing method is high cost (involving expensive telephone costs). So, it was eventually applied to an internet system for remote monitoring. According to the internet-based Virtual Private Network(VPN) applied to remote monitoring, the Korea Atomic Energy Research Institute(KAERI) came to an agreement with the IAEA, using a Member State Support Program(MSSP). Phase I is a lab test. Phase II is to apply it to a target power plant. Phase III is to apply it to all the power plants. This paper reports on the penetration testing of phase I. Phase I involved both domestic testing and international testing. The target of the testing consisted of a Surveillance Digital Integrated system(SDIS) server, IAEA server and TCNC(Technology Center for Nuclear Control) server. In each system, Virtual Private Network(VPN) system hardware was installed. The penetration of the three systems and the three VPNs was tested. The domestic test involved two hacking scenarios: hacking from the outside and hacking from the inside. The international test involved one scenario from the outside. The results of tests demonstrated that the VPN hardware provided a good defense against hacking. We verified that there was no invasion of the system (SDIS server and VPN; TCNC server and VPN; and IAEA server and VPN) via penetration testing.

  16. Vulnerability analysis on a VPN for a remote monitoring system

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Kim, Jong Soo; Park, Il Jin; Min, Kyung Sik; Choi, Young Myung

    2004-01-01

    14 Pressurized Water Reactors(PWR) in Korea use a Remote Monitoring System(RMS), which have been in Korea Since 1998. A memorandum of understanding on remote monitoring, based on enhanced cooperation on PWRs, was signed at the 10th safeguards review meeting in October 2001 between the International Atomic Energy Agency(IAEA) and Ministry Of Science and Technology(MOST). Thereafter, all PWR power plants applied for remote monitoring systems. However, the existing method is high cost (involving expensive telephone costs). So, it was eventually applied to an internet system for remote monitoring. According to the internet-based Virtual Private Network(VPN) applied to remote monitoring, the Korea Atomic Energy Research Institute(KAERI) came to an agreement with the IAEA, using a Member State Support Program(MSSP). Phase I is a lab test. Phase II is to apply it to a target power plant. Phase III is to apply it to all the power plants. This paper reports on the penetration testing of phase I. Phase I involved both domestic testing and international testing. The target of the testing consisted of a Surveillance Digital Integrated system(SDIS) server, IAEA server and TCNC(Technology Center for Nuclear Control) server. In each system, Virtual Private Network(VPN) system hardware was installed. The penetration of the three systems and the three VPNs was tested. The domestic test involved two hacking scenarios: hacking from the outside and hacking from the inside. The international test involved one scenario from the outside. The results of tests demonstrated that the VPN hardware provided a good defense against hacking. We verified that there was no invasion of the system (SDIS server and VPN; TCNC server and VPN; and IAEA server and VPN) via penetration testing

  17. Characterizing noise in the global nuclear weapon monitoring system

    Science.gov (United States)

    Schultz, Colin

    2013-03-01

    Under the auspices of the Comprehensive Nuclear-Test-Ban Treaty Organization, a worldwide monitoring system designed to detect the illegal testing of nuclear weaponry has been under construction since 1999. The International Monitoring System is composed of a range of sensors, including detectors for hydroacoustic and seismic signals, and when completed, will include 60 infrasound measurement arrays set to detect low-frequency sound waves produced by an atmospheric nuclear detonation.

  18. The Design of Bulk Carrier Cargo Holds State Integrated Monitoring System

    Directory of Open Access Journals (Sweden)

    Gao Ru-jiang

    2016-01-01

    Full Text Available Most ship cargo hold Internal uses artificial watch or is unattended. Therefore, it is impossible to know the appropriate information of the cargo holds Internal timely and accurately. Cargo damage and ship accidents occurred frequently. Automation remote processing and monitoring alarm system for the bulk carrier is an important part of the marine automation. The system plays a significant role to guarantee the navigation safety for bulk carriers. The paper introduced the important parts of the integrated monitoring system, structural design, hardware configuration, various modules communication transmission and various data processing software design were included. Based on embedded development, the real time information including the cargo hold internal humidity temperature, oxygen concentration, smoke gas concentration, cold water well level and other data were collected, as well the hatch closed state was detected and the cargo hold internal real time video information was collected. Then the real-time communication between the control display and acquisition modules were assured. By adjusting the corresponding buttons on the bridge according to the monitoring information, so that the cargo hold always in a safe environment, so as to avoid cargo hold accidents.

  19. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

  20. Universal Authenticated Item Monitoring System (AIMS) second generation equipment

    International Nuclear Information System (INIS)

    Schoeneman, J.L.; Baumann, M.J.; Fox, L.J.; Jenkins, C.D.; Perlinsk, A.W.

    1992-01-01

    Sandia National Laboratories (SNL) is in the final stages of developing a Universal Authenticated Item Monitoring System (AIMS). When completed, AIMS will provide applicable agencies in the US government, and those in the International arena, with a secure and convenient method of monitoring the physical status of selected items. The benefit derived from this development activity will be the commercial availability of an item monitoring system with the capability for ''quick set-up'' monitoring, as well as long-term unattended monitoring. The AIMS includes a variety of sensors, a robust and authenticated radio frequency (RF) communication link, a Receiver Processing Unit (RPU), and an inspector-friendly personal computer (PC) interface for collecting, sorting, viewing and archiving pertinent event histories. The system will provide the capability to monitor selected items in a real-time mode, a remotely interrogated mode, and a stand-alone, unattended data collection mode. The sensor suite under development includes advanced motion sensors, interior volumetric intrusion sensors, Re-usable, In-situ Verifiable Authenticated (RIVA) fiber-optic seal sensors, generic utility sensors (to accommodate contact closure inputs), and radiation and environmental sensors. A new generation authentication algorithm recently has been developed that provides a high degree of system security 121. The AIMS has potential safeguards applications in the areas of arms control and treaty verification military asset control, International Atomic Energy Agency (IAEA) and Euratom safeguards verification activities, as well as domestic nuclear safeguard activities. Commercial applications could include high-value inventory control and security systems. This paper describes the second-generation AIMS along with its recently expanded sensor suite and enhanced data collection capabilities

  1. Monitoring internal organ motion with continuous wave radar in CT

    International Nuclear Information System (INIS)

    Pfanner, Florian; Maier, Joscha; Allmendinger, Thomas; Flohr, Thomas; Kachelrieß, Marc

    2013-01-01

    Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the

  2. ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

    Science.gov (United States)

    Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.; hide

    2009-01-01

    ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

  3. Development of an expert system for the taking into account of uncertainties in the monitoring of internal contaminations

    International Nuclear Information System (INIS)

    Davesne, E.; Blanchardon, E.; Casanova, P.; Chojnacki, E.; Paquet, F.

    2010-01-01

    Internal contaminations may result from professional exposure and they can be monitored by anthropo-radiometric and radio-toxicological measurements which are interpreted in terms of embedded activity and effective dose by means of biokinetic and dosimetric models. In spite of standards, some uncertainties in the dosimetric interpretation of radio-toxicological measurements may remain. The authors report the development of a software (OPSCI code) which takes into account uncertainties related to the worker internal dosimetry, the calculation of the minimum detectable dose related to an exposure, and the development of a data monitoring programme

  4. Feed the Future Monitoring System Aggregate Data 2011-2014

    Data.gov (United States)

    US Agency for International Development — The Feed the Future Monitoring System (FTFMS) is part of an interagency effort to consolidate U.S. Government (USG) reporting on Feed the Future activities. FTFMS...

  5. Requirements for internal contamination monitoring units

    International Nuclear Information System (INIS)

    Werner, E.; Beyer, D.; Doerfel, H.; Erlenbach, H.; Fischbach, G.; Henrichs, K.; Keller, K.D.; Koenig, K.; Riedel, W.; Scheler, R.; Schieferdecker, H.

    1994-01-01

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [de

  6. Performance Monitoring Framework for Service Oriented System Lifecycle

    OpenAIRE

    Masood , Tehreem; Cherifi , Chantal; Moalla , Néjib

    2016-01-01

    International audience; Service oriented systems are highly dynamic systems composed of several web services. One of the most important challenges in service oriented systems is to deliver acceptable quality of service. For this purpose, it is required to monitor quality of service along different activities of service oriented system. Existing research focuses on specific activities but do not take into account all the activities of service oriented system together at the infrastructure leve...

  7. Internationally coordinated glacier monitoring: strategy and datasets

    Science.gov (United States)

    Hoelzle, Martin; Armstrong, Richard; Fetterer, Florence; Gärtner-Roer, Isabelle; Haeberli, Wilfried; Kääb, Andreas; Kargel, Jeff; Nussbaumer, Samuel; Paul, Frank; Raup, Bruce; Zemp, Michael

    2014-05-01

    Internationally coordinated monitoring of long-term glacier changes provide key indicator data about global climate change and began in the year 1894 as an internationally coordinated effort to establish standardized observations. Today, world-wide monitoring of glaciers and ice caps is embedded within the Global Climate Observing System (GCOS) in support of the United Nations Framework Convention on Climate Change (UNFCCC) as an important Essential Climate Variable (ECV). The Global Terrestrial Network for Glaciers (GTN-G) was established in 1999 with the task of coordinating measurements and to ensure the continuous development and adaptation of the international strategies to the long-term needs of users in science and policy. The basic monitoring principles must be relevant, feasible, comprehensive and understandable to a wider scientific community as well as to policy makers and the general public. Data access has to be free and unrestricted, the quality of the standardized and calibrated data must be high and a combination of detailed process studies at selected field sites with global coverage by satellite remote sensing is envisaged. Recently a GTN-G Steering Committee was established to guide and advise the operational bodies responsible for the international glacier monitoring, which are the World Glacier Monitoring Service (WGMS), the US National Snow and Ice Data Center (NSIDC), and the Global Land Ice Measurements from Space (GLIMS) initiative. Several online databases containing a wealth of diverse data types having different levels of detail and global coverage provide fast access to continuously updated information on glacier fluctuation and inventory data. For world-wide inventories, data are now available through (a) the World Glacier Inventory containing tabular information of about 130,000 glaciers covering an area of around 240,000 km2, (b) the GLIMS-database containing digital outlines of around 118,000 glaciers with different time stamps and

  8. Radioactive gases monitor system: tritium, radon, noble gases

    International Nuclear Information System (INIS)

    Egey, J.Z.; Matatagui, E.

    2015-01-01

    A system for monitoring the radioactive gases tritium, radon and noble gases is described. We present the description of the sensor and the associated electronics that have been developed to monitor the presence of radioactive gases in air or other gaseous effluents. The system has a high sensitivity and a wide range of operation. The sensor is an ionization chamber, featuring the internal circulation of the gas to monitor and the associated electronics has a resolution better than 10 E-15A (fA). It allows the detection of the individual pulses that are produced during the alpha decay of radon and its daughter elements. The measurement system is made up of a commercial data acquisition system connected to a computer. The acquired data is presented on a graphical display and it is stored for later processing and analysis. We have a system that is of simple construction and versatile. Here we present the experimental results. (authors) [es

  9. Monitoring external and internal loads of brazilian soccer referees during official matches.

    Science.gov (United States)

    Costa, Eduardo C; Vieira, Caio M A; Moreira, Alexandre; Ugrinowitsch, Carlos; Castagna, Carlo; Aoki, Marcelo S

    2013-01-01

    This study aimed to assess the external and internal loads of Brazilian soccer referees during official matches. A total of 11 field referees (aged 36.2 ± 7.5 years) were monitored during 35 matches. The external (distance covered, mean and maximal speed) and internal load parameters (session ratings of perceived exertion [RPE] training load [TL], Edwards' TL, and time spent in different heart rate [HR] zones) were assessed in 3-4 matches per referee. External load parameters were measured using a wrist Global Positioning System (GPS) receiver. No differences in distance covered (5.219 ± 205 vs. 5.230 ± 237 m) and maximal speed (19.3 ± 1.0 vs. 19.4 ± 1.4 km·h(-1)) were observed between the halves of the matches (p > 0.05). However, the mean speed was higher in the first half of the matches (6.6 ± 0.4 vs. 6.4 ± 0.3 km·h(-1)) (p external and internal load demands during official matches. The portable GPS/HR monitors and session RPE method can provide relevant information regarding the magnitude of the physiological strain during official matches. Key PointsHigh external and internal loads were imposed on Brazilian soccer referees during official matches.There was a high positive correlation between a subjective marker of internal load (session RPE) and parameters of external load (distance covered between 90-100% of HRmax and maximal speed).There was a high positive correlation between session RPE method and Edwards' method.Session RPE seems to be a reliable marker of internal load.The portable GPS/HR monitors and the session RPE method can provide relevant information regarding the magnitude of external and internal loads of soccer referees during official matches.

  10. Construct mine environment monitoring system based on wireless mesh network

    Science.gov (United States)

    Chen, Xin; Ge, Gengyu; Liu, Yinmei; Cheng, Aimin; Wu, Jun; Fu, Jun

    2018-04-01

    The system uses wireless Mesh network as a network transmission medium, and strive to establish an effective and reliable underground environment monitoring system. The system combines wireless network technology and embedded technology to monitor the internal data collected in the mine and send it to the processing center for analysis and environmental assessment. The system can be divided into two parts: the main control network module and the data acquisition terminal, and the SPI bus technology is used for mutual communication between them. Multi-channel acquisition and control interface design Data acquisition and control terminal in the analog signal acquisition module, digital signal acquisition module, and digital signal output module. The main control network module running Linux operating system, in which the transplant SPI driver, USB card driver and AODV routing protocol. As a result, the internal data collection and reporting of the mine are realized.

  11. The development of NSSS digital integrity monitoring system

    International Nuclear Information System (INIS)

    Ham, Chang Shik; Kim, Jung Soo; Jung, Chul Hwan; Hwang, In Koo; Kim, Tak Hwane; Kim, Tae Hwane; Park, Jin Ho; Kyung, Sung Yoon; Hyeon, Ryu Kye; Seong, Joo Hyun; Kim, Georn Myung; Eun, Sung Hun; Kwack, Jin Gu; Park, Joon Hee

    1999-11-01

    The primary function of loose part monitoring system (LPMS) is to detect the occurrence of any loose part in the primary coolant system caused by being parted or loosened from the mechanical structure during normal operation and refueling times. The existing LPMSs generates an alarm when the detected signal from the accelerometer sensors attached to the surface of the primary pressure boundary was bigger than the alarm threshold value. The internal vibration monitoring system (IVMS) senses a change of vibration of the reactor vessel internal structure using the ex-core neutron signals. The vibrations of internal mechanical structure are caused by the high velocity flow of the pressurized primary coolant. If the flow-induced vibration forces to loosen the internal components supporting the fuel assembly, the safety of nuclear reactor will be affected. The IVMS provides the information of abnormality in the vibration pattern and amplitude for plant operators to take proper actions against the abnormal condition for nuclear power plants (NPPs). An advanced LPMS should be capable to identify the physical characteristics of the potential loose part from the detected signal. Those improved diagnostic function will be the capabilities to analyze the detected signal and to estimate the expected impact position and mass automatically. The technologies and methods of estimation for impact mass and position as well as a new modeling method of reactor internal vibration modes were developed and provided to Woojin Co. from Korea Energy Research Institute (KAERI). Based on the transferred technologies, Woojin Co. has designed the hardware system of LPMS and IVMS. Some of the hardware components were integrated and the hardware-oriented software modules were also developed and designed. (author)

  12. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  13. OMINEX: Development of Guidance on Monitoring for Internal Exposure

    International Nuclear Information System (INIS)

    Etherington, G.; Ansoborlo, E.; Berard, P.; Cossonnet, C.; Frank, D.; Genicot, A.; Hodgson, A.; Hurtgen, C.; Jourdain, J. R.; Le Gueen, B.; Rahola, T.; Sovijarvi, J.; Stradling, G. N.

    2004-01-01

    The aim of the OMINEX project was to provide advice and guidance on the design and implementation of internal dose monitoring programmes in the workplace in such a way that best use is made of available resources, while minimising costs. Topics addressed include choice of monitoring method(s), (eg excretion monitoring vs. in vivo monitoring), choice of measurement technique (eg alpha spectrometry vs. mass spectrometry), monitoring intervals, measurement frequency, required measurement sensitivity and accuracy, measurement parameters needed to achieve this performance, the resulting uncertainty in assessed intakes and doses, and minimum detectable doses. The underlying approach to optimisation was to consider costs versus benefits, the latter being quantified primarily by assessing the sensitivity or accuracy with which intakes and doses are determined from the results of particular monitoring methods. The aim of this paper is to present an overview of the results of the project. Some of the main results of surveys of current internal dose monitoring practice and the costs of monitoring programmes are presented. Recommendations on the optimisation of bioassay and in vivo measurement parameters are discussed. A novel method for the assessment of uncertainty in assessed intakes and doses is described, and the use of information on uncertainties in designing a monitoring programme is discussed using the example of tritium-in-urine monitoring. Recommendations are described for the monitoring of exposures to compounds of uranium, plutonium, thorium and caesium encountered in the nuclear industries. (Author) 15 refs

  14. Direct internal dosimetry. A new way for routine incorporation monitoring of γ-emitting radionuclides

    International Nuclear Information System (INIS)

    Doerfel, H.

    1996-01-01

    The INDOS detector system offers the following advantages with respect to routine incorporation monitoring: The measurement is performed automatically and there is no need for trained staff. The measuring time is short and thus a relative large number of persons may be monitored with a relative high measuring frequency. First estimates of the individual effective dose equivalent rate are available immediately after the measurement. 1) The direct determination of the dose equivalent in principle is more precise than the conventional procedures for internal dosimetry, because (i) the retention of radionuclides in the body may be measured explicitly and (ii) the dependence of the dose equivalent on the body proportions is corrected implicitly. 2) The measuring procedure is comparable to the external dosimetry with respect to accuracy and lower limit of detection. Thus, the results of internal and external dosimetry can be summed up in an easy and reasonable manner. 3) The detector system can be installed in any building; it also can be installed as a mobile unit in a car or a container for long distance transportation by aircraft or train. 4) Last but not least, the cost for monitoring with INDOS is much lower than for the conventional monitoring procedures using whole body counters. (author)

  15. Corral Monitoring System assessment results

    International Nuclear Information System (INIS)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system

  16. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  17. A low frequency RFI monitoring system

    Science.gov (United States)

    Amiri, Shahram; Shankar, N. Udaya; Girish, B. S.; Somashekar, R.

    Radio frequency interference (RFI) is a growing problem for research in radio astronomy particularly at wavelengths longer than 2m. For satisfactory operation of a radio telescope, several bands have been protected for radio astronomy observations by the International Telecommunication Union. Since the radiation from cosmic sources are typically 40 to 100 dB below the emission from services operating in unprotected bands, often the out-of-band emission limits the sensitivity of astronomical observations. Moreover, several radio spectral emissions from cosmic sources are present in the frequency range outside the allocated band for radio astronomy. Thus monitoring of RFI is essential before building a receiver system for low frequency radio astronomy. We describe the design and development of an RFI monitoring system operating in the frequency band 30 to 100 MHz. This was designed keeping in view our proposal to extend the frequency of operation of GMRT down to 40 MHz. The monitor is a PC based spectrometer recording the voltage output of a receiver connected to an antenna, capable of digitizing the low frequency RF directly with an 8 bit ADC and sampling bandwidths up to 16 MHz. The system can operate continuously in almost real-time with a loss of only 2% of data. Here we will present the systems design aspects and the results of RFI monitoring carried out at the Raman Research Institute, Bangalore and at the GMRT site in Khodad.

  18. Considerations of selection suggested for internal contamination monitoring in Cuba

    International Nuclear Information System (INIS)

    Cruz S, R.; Lopez B, G.; Placeres V, C.; Arado L, J.; Jova S, L.

    1996-01-01

    A method for calculating effective risk of radionuclide intake and hypothetical annual dose that will receive a person who works with unsealed sources is proposed. Calculated committed dose equivalent and metabolic characteristic of radionuclides permit to select the type of monitoring 'in vivo' and/or 'in vitro'. The method was applied to 396 workers from 28 institutions, where 20 radionuclides in 124 different products for 266 applications are used. From this study 62% of the workers had to be monitored for internal contamination, meanly by 'in vitro' monitoring. In practices of Nuclear Medicine and other medical uses 75% of the workers had to be monitored. These results permitted to corroborate the criteria for internal contamination monitoring program carried out by Center for Hygiene and Radiation Protection and permitted to identify needs for control of radionuclides intakes. (authors).5 refs., 3 figs

  19. What is New in Internal Dosimetry and Monitoring?

    International Nuclear Information System (INIS)

    Henrichs, K.; Nosske, D.

    2006-01-01

    This file is divided in two parts:the first one concerns the progress in internal dosimetry. This part gives an overview on new model developments by ICRP, the series of age dependent doses for members of the public was continued by biokinetic and dosimetric models for the embryo and foetus due to activity intake by the mother (ICRP,2001) and for the infant via consumption of mother's milk after activity intake by the mother (ICRP, 2004). In both publications dose coefficients for the embryo and foetus as well the infant were given for various intake scenarios by mother. The present model development work of ICRP is a revision of Publications 30, 54, 68, and 78 based on the new human Alimentary tract model (H.A.T.M.) of ICRP (ICRP, 2006), a revision of absorption parameters for the human respiratory tract model (ICRP, 1994a), new systemic models as well as new dosimetric parameters derived with new Voxel models for the reference male and female adult. The second part concerns the progress in workers monitoring for radionuclide intake. The initiatives to improve the situation are the guidelines published by the International Atomic Energy Agency (2004), giving guidance for the assessment of occupational exposures due to intakes of radionuclides, research project funded by the European Commission: the objective of O.M.I.N.E.X. was the improvement of monitoring programmes, taking into account the uncertainties of biokinetic models and data, the programme I.D.E.A. tried to improve measuring techniques and I.D.E.A.S derives rules for the evaluation of measured activity values in terms of exposure. Standardization projects by the International Standardization Organization I.S.O.: I.S.O. (2001) published a standard defining the requirements for bioassay laboratories, which will soon followed by a second part giving the rationale behind these rules., presently the final version (I.S.O. 2005) of a standard is circulating among the I.S.O. member states which guidance on the

  20. Individual monitoring for internal exposure of workers - regulation and practice in Hungary

    International Nuclear Information System (INIS)

    Kerekes, A.; Kocsy, G.; Pellet, S.

    2005-01-01

    Full text: Decree of Ministry of Health for the enforcement of the Act on Atomic Energy has put special emphasis on the regulation of monitoring for internal exposure in Hungary. The necessarily general prescription of the Decree 'In case of the possibility or suspicion of incorporating open radioactive substances the affected employee shall be subjected to internal contamination monitoring. The obligation of the internal monitoring shall be determined by the Radiation Hygiene Centre of the National Public Health and Medical Officer's Service' called for a guidance to assist the work of the competent authority. The guide was elaborated on the basis of the IAEA Safety Guide No. RS-G-1.2. According to the Safety Guide the decision factor shall first be determined for the potential radionuclides and practice applied. For routine monitoring the required frequency, method and MDA values, moreover for special monitoring the method and MDA values were derived for over 40 radionuclides considering the following two basic assumptions: the activity remaining in or excreted from the body could be determined by the given measurement method, the possible underestimation of intake shall be less than a factor of three within the monitoring interval. The following prescription of the Decree 'The laboratory performing the monitoring of internal exposure shall be accredited' has raised a conflict in practice. To solve the problem the Guide suggests a two-step monitoring process: a screening measurement for the possible internal contamination performed by the Radiation Protection Service of the workplace by any equipment used in daily practice for investigation of patients, radiation protection purposes, etc., if the result of screening indicates an internal contamination the radiation worker shall be monitored by an accredited laboratory. As an ISO Standard in process has several assumptions differing from the IAEA Safety Guide, e.g. the limitation of 'maximum potential

  1. Re-materialising energy use through transparent monitoring systems

    International Nuclear Information System (INIS)

    Burgess, Jacquelin; Nye, Michael

    2008-01-01

    This paper reviews the effect of transparent energy monitoring systems on the purchasing, production and energy use behaviour of consumers and producers. Relevant literature is explored on the linkages between feedback, risk and responsibility, knowledge, economic drivers, and sustainable energy consumption. Drawing on international as well as UK-specific experiences, the paper focuses on the prospects for current and future energy monitoring systems to 're-materialise' energy use in economic and environmental terms that are more meaningful, and thus more behaviourally significant, to a substantially wider range of energy users than today's. Appliance labelling, smart metering and carbon footprint analyses are explored as case studies

  2. The challenge of Ciemat internal dosimetry service for accreditation according to ISO/IEC 17025 standard, for in vivo and in vitro monitoring and dose assessment of internal exposures

    International Nuclear Information System (INIS)

    Lopez, M.A.; Martin, R.; Hernandez, C.; Navarro, J.F.; Navarro, T.; Perez, B.; Sierra, I.

    2016-01-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. CIEMAT Internal Dosimetry Service (IDS) has developed and implemented a quality system based on ISO/IEC 17025 to ensure compliance with the general requirements of this reference standard. The development of documentary support according to this quality system permitted to standardise the systematic activities performed within the whole body counter and in vitro bioassay laboratories as well as the procedures carried out by qualified staff in charge of internal dose assessment. There was no previous experience in the accreditation of other internal dosimetry services in Spain. Then, requirements from the national regulatory body (Nuclear Safety Council, CSN) and national accreditation entity (ENAC) have been considered. The main concerns were to guarantee the traceability in the whole process and to avoid possible charge of interpretation or subjectivity in the methodology of dose assessment due to intakes of radionuclides when calculating from monitoring data. All the related international standards dealing with internal dosimetry were taken into account: ISO 28218 'Performance criteria for radiobioassay', ISO 27048 'Dose Assessment for the

  3. Technical results of Y-12/IAEA field trial of remote monitoring system

    International Nuclear Information System (INIS)

    Corbell, B.H.; Whitaker, J.M.; Welch, J.

    1997-01-01

    A Remote Monitoring System (RMS) field trial has been conducted with the International Atomic Energy Agency (IAEA) on highly enriched uranium materials in a vault at the Oak Ridge Y-12 Plant. The RMS included a variety of Sandia, Oak Ridge, and Aquila sensor technologies which provide containment seals, video monitoring, radiation asset measurements, and container identification data to the on-site DAS (Data Acquisition System) by way of radio-frequency and Echelon LonWorks networks. The accumulated safeguards information was transmitted to the IAEA via satellite (COMSAT/RSI) and international telephone lines. The technologies tested in the remote monitoring environment are the RadCouple, RadSiP, and SmartShelf sensors from the ORSENS (Oak Ridge Sensors for Enhancing Nuclear Safeguards) technologies; the AIMS (Authenticated Item Monitoring System) motion sensor (AMS), AIMS fiber-optic seal (AFOS), ICAM (Image Compression and Authentication Module) video surveillance system, DAS (Data Acquisition System), and DIRS (Data and Image Review Station) from Sandia; and the AssetLAN identification tag, VACOSS-S seal, and Gemini digital surveillance system from Aquila. The field trial was conducted from October 1996 through May 1997. Tests were conducted during the monthly IAEA Interim Inventory Verification (IIV) inspections for evaluation of the equipment. Experience gained through the field trials will allow the technologies to be applied to various monitoring scenarios

  4. Monitoring of patients treated with lithium for bipolar disorder: an international survey.

    Science.gov (United States)

    Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W

    2018-04-14

    Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.

  5. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  6. The passive seismic aftershock Monitoring system: testing program and preliminary results

    International Nuclear Information System (INIS)

    Mokhtari, M.

    2005-01-01

    The paper is dedicated to testing program (phase of the passive seismic aftershock monitoring system with RefTek equipment (Refraction Technology, Inc., USA) for On-Site Inspection purposes that was carried out near Vienna International Centre in 2000. Equipment and applied software are described. Testing results were analyzed; in particular, least needs in maintenance personnel during operation. Development perspectives of passive seismic aftershock monitoring system for On-Site Inspection have been discussed. (author)

  7. Implementation of remove monitoring in facilities under safeguards with unattended systems

    International Nuclear Information System (INIS)

    Beddingfield, David H.; Nordquist, Heather A.; Umebayaashi, Eiji

    2009-01-01

    Remote monitoring is being applied by the International Atomic Energy Agency (IAEA) at nuclear facilities around the world. At the Monju Reactor in Japan we have designed, developed and implemented a remote monitoring approach that can serve as a model for applying remote monitoring to facilities that are already under full-scope safeguards using unattended instrumentation. Remote monitoring implementations have historically relied upon the use of specialized data collection hardware and system design features that integrate remote monitoring into the safeguards data collection system. The integration of remote monitoring and unattended data collection increases the complexity of safeguards data collection systems. This increase in complexity necessarily produces a corresponding reduction of system reliability compared to less-complex unattended monitoring systems. At the Monju facility we have implemented a remote monitoring system that is decoupled from the activity of safeguards data collection. In the completed system the function of remote data transfer is separated from the function of safeguards data collection. As such, a failure of the remote monitoring function cannot produce an associated loss of safeguards data, as is possible with integrated remote-monitoring implementations. Currently, all safeguards data from this facility is available to the IAEA on a 24/7 basis. This facility employs five radiation-based unattended systems, video surveillance and numerous optical seal systems. The implementation of remote monitoring at this facility, while increasing the complexity of the safeguards system, is designed to avoid any corresponding reduction in reliability of the safeguards data collection systems by having decoupled these functions. This design and implementation can serve as a model for implementation of remote monitoring at nuclear facilities that currently employ unattended safeguards systems.

  8. A design methodology for unattended monitoring systems

    International Nuclear Information System (INIS)

    SMITH, JAMES D.; DELAND, SHARON M.

    2000-01-01

    The authors presented a high-level methodology for the design of unattended monitoring systems, focusing on a system to detect diversion of nuclear materials from a storage facility. The methodology is composed of seven, interrelated analyses: Facility Analysis, Vulnerability Analysis, Threat Assessment, Scenario Assessment, Design Analysis, Conceptual Design, and Performance Assessment. The design of the monitoring system is iteratively improved until it meets a set of pre-established performance criteria. The methodology presented here is based on other, well-established system analysis methodologies and hence they believe it can be adapted to other verification or compliance applications. In order to make this approach more generic, however, there needs to be more work on techniques for establishing evaluation criteria and associated performance metrics. They found that defining general-purpose evaluation criteria for verifying compliance with international agreements was a significant undertaking in itself. They finally focused on diversion of nuclear material in order to simplify the problem so that they could work out an overall approach for the design methodology. However, general guidelines for the development of evaluation criteria are critical for a general-purpose methodology. A poor choice in evaluation criteria could result in a monitoring system design that solves the wrong problem

  9. Internal Electrostatic Discharge Monitor - IESDM

    Science.gov (United States)

    Kim, Wousik; Goebel, Dan M.; Jun, Insoo; Garrett, Henry B.

    2011-01-01

    A document discusses an innovation designed to effectively monitor dielectric charging in spacecraft components to measure the potential for discharge in order to prevent damage from internal electrostatic discharge (IESD). High-energy electrons penetrate the structural materials and shielding of a spacecraft and then stop inside dielectrics and keep accumulating. Those deposited charges generate an electric field. If the electric field becomes higher than the breakdown threshold (approx. =2 x 10(exp 5) V/cm), discharge occurs. This monitor measures potentials as a function of dielectric depth. Differentiation of potential with respect to the depth yields electric field. Direct measurement of the depth profile of the potential in a dielectric makes real-time electronic field evaluation possible without simulations. The IESDM has been designed to emulate a multi-layer circuit board, to insert very thin metallic layers between the dielectric layers. The conductors serve as diagnostic monitoring locations to measure the deposited electron-charge and the charge dynamics. Measurement of the time-dependent potential of the metal layers provides information on the amount of charge deposited in the dielectrics and the movement of that charge with time (dynamics).

  10. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  11. Environmental monitoring with a portable TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P P; Feher, I; Deme, S; Szabo, B; Vagvoelgyi, J; German, E [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    Two types of TLD systems are used for environmental dose monitoring. One is based on an NHZ-203 laboratory TLD reader and CaSO/sub 4/:Dy powder. The other is based on CaSO/sub 4/:Tm bulbs and a small, portable TLD reader built into a cross-country car and operated by means of the car battery. The laboratory TLD system has been used for many years for environmental monitoring and it has been tested and proved satisfactory at international intercomparisons for environmental dosemeters. The new portable TLD system has the advantage of being able to establish the dose in a few minutes at the environmental station. The transport dose is omitted as the TLDs are evaluated at the field site. The evaluation of a bulb needs only a few minutes and the measured dose value can be reported back by radio - an important aspect during an emergency situation.

  12. WIPP Transparency Project - container tracking and monitoring demonstration using the Authenticated Tracking and Monitoring System (ATMS)

    International Nuclear Information System (INIS)

    SCHOENEMAN, J. LEE; SMARTT, HEIDI ANNE; HOFER, DENNIS

    2000-01-01

    The Authenticated Tracking and Monitoring System (ATMS) is designed to answer the need for global monitoring of the status and location of proliferation-sensitive items on a worldwide basis, 24 hours a day. ATMS uses wireless sensor packs to monitor the status of the items within the shipment and surrounding environmental conditions. Receiver and processing units collect a variety of sensor event data that is integrated with GPS tracking data. The collected data are transmitted to the International Maritime Satellite (INMARSAT) communication system, which then sends the data to mobile ground stations. Authentication and encryption algorithms secure the data during communication activities. A typical ATMS application would be to track and monitor the stiety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements

  13. What is New in Internal Dosimetry and Monitoring?

    Energy Technology Data Exchange (ETDEWEB)

    Henrichs, K. [Siemens AG, Corporate Radiation Safety and Dangerous Goods Transport, Munich (Germany); Nosske, D. [Federal Office for Radiation Protection, Neuherberg (Germany)

    2006-07-01

    This file is divided in two parts:the first one concerns the progress in internal dosimetry. This part gives an overview on new model developments by ICRP, the series of age dependent doses for members of the public was continued by biokinetic and dosimetric models for the embryo and foetus due to activity intake by the mother (ICRP,2001) and for the infant via consumption of mother's milk after activity intake by the mother (ICRP, 2004). In both publications dose coefficients for the embryo and foetus as well the infant were given for various intake scenarios by mother. The present model development work of ICRP is a revision of Publications 30, 54, 68, and 78 based on the new human Alimentary tract model (H.A.T.M.) of ICRP (ICRP, 2006), a revision of absorption parameters for the human respiratory tract model (ICRP, 1994a), new systemic models as well as new dosimetric parameters derived with new Voxel models for the reference male and female adult. The second part concerns the progress in workers monitoring for radionuclide intake. The initiatives to improve the situation are the guidelines published by the International Atomic Energy Agency (2004), giving guidance for the assessment of occupational exposures due to intakes of radionuclides, research project funded by the European Commission: the objective of O.M.I.N.E.X. was the improvement of monitoring programmes, taking into account the uncertainties of biokinetic models and data, the programme I.D.E.A. tried to improve measuring techniques and I.D.E.A.S derives rules for the evaluation of measured activity values in terms of exposure. Standardization projects by the International Standardization Organization I.S.O.: I.S.O. (2001) published a standard defining the requirements for bioassay laboratories, which will soon followed by a second part giving the rationale behind these rules., presently the final version (I.S.O. 2005) of a standard is circulating among the I.S.O. member states which guidance on

  14. Necessity of Internal Monitoring for Nuclear Medicine Staff in a Large Specialized Chinese Hospital.

    Science.gov (United States)

    Wang, Hong-Bo; Zhang, Qing-Zhao; Zhang, Zhen; Hou, Chang-Song; Li, Wen-Liang; Yang, Hui; Sun, Quan-Fu

    2016-04-12

    This work intends to quantify the risk of internal contaminations in the nuclear medicine staff of one hospital in Henan province, China. For this purpose, the criteria proposed by the International Atomic Energy Agency (IAEA) to determine whether it is necessary to conduct internal individual monitoring was applied to all of the 18 nuclear medicine staff members who handled radionuclides. The activity of different radionuclides used during a whole calendar year and the protection measures adopted were collected for each staff member, and the decision as to whether nuclear medicine staff in the hospital should be subjected to internal monitoring was made on the basis of the criteria proposed by IAEA. It is concluded that for all 18 members of the nuclear medicine staff in the hospital, internal monitoring is required. Internal exposure received by nuclear medicine staff should not be ignored, and it is necessary to implement internal monitoring for nuclear medicine staff routinely.

  15. International Collaboration in the field of GNSS-Meteorology and Climate Monitoring

    Science.gov (United States)

    Jones, J.; Guerova, G.; Dousa, J.; Bock, O.; Elgered, G.; Vedel, H.; Pottiaux, E.; de Haan, S.; Pacione, R.; Dick, G.; Wang, J.; Gutman, S. I.; Wickert, J.; Rannat, K.; Liu, G.; Braun, J. J.; Shoji, Y.

    2012-12-01

    International collaboration in the field of GNSS-meteorology and climate monitoring is essential, as severe weather and climate change have no respect for national boundaries. The use of Global Navigation Satellite Systems (GNSS) for meteorological purposes is an established atmospheric observing technique, which can accurately sense water vapour, the most abundant greenhouse gas, accounting for 60-70% of atmospheric warming. Severe weather forecasting is challenging, in part due to the high temporal and spatial variation of atmospheric water vapour. Water vapour is currently under-sampled and obtaining and exploiting more high-quality humidity observations is essential to severe weather forecasting and climate monitoring. A proposed EU COST Action (http://www.cost.eu) will address new and improved capabilities from concurrent developments in both GNSS and atmospheric communities to improve (short-range) weather forecasts and climate projections. For the first time, the synergy of the three GNSS systems, GPS, GLONASS and Galileo, will be used to develop new, advanced tropospheric products, stimulating the full potential exploitation of multi-GNSS water vapour estimates on a wide range of temporal and spatial scales, from real-time severe weather monitoring and forecasting to climate research. The Action will work in close collaboration with the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN), GNSS Precipitable Water Task Team (TT). GRUAN is a global reference observing network, designed to meet climate requirements and to fill a major void in the current global observing system. GRUAN observations will provide long-term, high-quality data to determine climatic trends and to constrain and validate data from space-based remote sensors. Ground-based GNSS PW was identified as a Priority 1 measurement for GRUAN, and the GNSS-PW TT's goal is to develop explicit guidance on hardware, software and data management practices to obtain GNSS PW

  16. 5 CFR 575.212 - Internal monitoring requirements and revocation or suspension of authority.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Relocation Incentives § 575.212 Internal monitoring...

  17. 5 CFR 575.312 - Internal monitoring requirements and revocation or suspension of authority.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Retention Incentives § 575.312 Internal monitoring...

  18. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  19. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  20. The International Editorship of Freshwater Systems

    Directory of Open Access Journals (Sweden)

    Karl E. Havens

    2001-01-01

    Full Text Available It is my pleasure to announce that two distinguished internationalscientists have joined the editorship of the FreshwaterSystems domain of TheScientificWorldJOURNAL — Professor BrijGopal of Jawaharlal Nehru University (India and Dr. Manual Gra柠of the Universityof Coimbra (Portugal. Professor Gopal is the Secretary General of the NationalInstitute of Ecology, Editor of the InternationalJournal of Ecology & Environmental Science,and Chairman of the SIL (International Association of Theoretical and AppliedLimnology Committee on Limnology in Developing Countries. His research interestsinclude the ecology, biogeochemistry and biodiversity of wetland ecosystems,the management of wetlands as an integral part of the watershed, and wetlandwater policy–related issues. Dr. Gra柠is a stream ecologist whose researchinterests include the two general areas of organic matter decomposition andbiological monitoring. His specific areas of research focus include quantificationof organic matter and other chemical changes in decomposing leaves, the ecologyof aquatic hyphomycetes, and the ecology of animals feeding on detritus. Hisresearch dealing with biological monitoring is carried out in close cooperationwith the paper and mining industries, facilitating the practical applicationof his work.

  1. Service models for remote healthcare monitoring systems.

    Science.gov (United States)

    Moorman, Bridget A

    2010-01-01

    These scenarios reflect where the future is heading for remote health monitoring technology and service expectations. Being able to manage a "system of systems" with timely service hand-off over seams of responsibility and system interfaces will become very important for a BMET or clinical engineer. These interfaces will include patient homes, clinician homes, commercial/civilian infrastructure, public utilities, vendor infrastructure as well as internal departmental domains. Concurrently, technology is changing rapidly resulting in newer software delivery modes and hardware appliances as well as infrastructure changes. Those who are able to de-construct the complex systems and identify infrastructure assumptions and seams of servicing responsibility will be able to better understand and communicate the expectations for service of these systems. Moreover, as identified in Case 1, prodigious use of underlying system monitoring tools (managing the "meta-data") could move servicing of these remote systems from a reactive approach to a proactive approach. A prepared healthcare organization will identify their current and proposed future service combination use cases and design service philosophies and expectations for those use cases, while understanding the infrastructure assumptions and seams of responsibility. This is the future of technical service to the healthcare clinicians and patients.

  2. Prospective evaluation of the need for internal monitoring

    International Nuclear Information System (INIS)

    Barton, T.P.; Bowers, R.R.; Volza, P.

    1992-01-01

    This paper reports that under the revision of 10 CFR 20, workers must be monitored for internal dose only if a prospective evaluation shows that they are likely to exceed 10 percent of an ALI in a year. Past positive whole body counts were reviewed at the Perry Nuclear Power Plant, and the largest uptake was found to be 1.3 percent of an ALI. Past RWPs which had the potential for significant airborne exposure were identified and reviewed. The highest possible uptake was calculated to be 2.5 percent of an ALI, not taking credit for respiratory protection. Committed dose from alpha and pure beta emitters which would not be identified by gamma-sensitive bioassay was found to be negligible. Based on this prospective evaluation, monitoring personnel for internal dose is not required at this facility

  3. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  4. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  5. The environment, international standards, asset health management and condition monitoring: An integrated strategy

    Energy Technology Data Exchange (ETDEWEB)

    Roe, S. [CSD, British Institute of Non-Destructive Testing (BINDT) (United Kingdom); Mba, D. [School of Engineering, Cranfield University, MK43 0AL, Bedfordshire (United Kingdom)], E-mail: d.mba@cranfield.ac.uk

    2009-02-15

    Asset Health Management (AHM), supported by condition monitoring (CM) and performance measuring technologies, together with trending, modelling and diagnostic frameworks, is not only critical to the reliability of high-value machines, but also to a companies Overall Equipment Efficiency (OEE), system safety and profitability. In addition these protocols are also critical to the global concern of the environment. Industries involved with monitoring key performances indicators (KPI) to improve OEE would benefit from a standardised qualification and certification scheme for their personnel, particularly if it is based on internationally accepted procedures for the various CM technologies that also share the same objectives as AH and CM. Furthermore, the development of 'models' for implementation of a Carbon tax is intrinsically dependent on the integrity and accuracy of measurements contributing to these indicators. This paper reviews the global picture of condition monitoring, the environment and related international standards and then considers their relationship and equivalent global objectives. In addition, it presents the methods behind the development of such standards for certification of competence in personnel involved with data collection, modelling and measurements of KPIs. Two case studies are presented that highlight the integrated strategy in practise.

  6. The environment, international standards, asset health management and condition monitoring: An integrated strategy

    International Nuclear Information System (INIS)

    Roe, S.; Mba, D.

    2009-01-01

    Asset Health Management (AHM), supported by condition monitoring (CM) and performance measuring technologies, together with trending, modelling and diagnostic frameworks, is not only critical to the reliability of high-value machines, but also to a companies Overall Equipment Efficiency (OEE), system safety and profitability. In addition these protocols are also critical to the global concern of the environment. Industries involved with monitoring key performances indicators (KPI) to improve OEE would benefit from a standardised qualification and certification scheme for their personnel, particularly if it is based on internationally accepted procedures for the various CM technologies that also share the same objectives as AH and CM. Furthermore, the development of 'models' for implementation of a Carbon tax is intrinsically dependent on the integrity and accuracy of measurements contributing to these indicators. This paper reviews the global picture of condition monitoring, the environment and related international standards and then considers their relationship and equivalent global objectives. In addition, it presents the methods behind the development of such standards for certification of competence in personnel involved with data collection, modelling and measurements of KPIs. Two case studies are presented that highlight the integrated strategy in practise

  7. Report. First international symposium on innovating mining systems

    Energy Technology Data Exchange (ETDEWEB)

    Blackwood, R L

    1985-01-01

    The author presents a summary of proceedings of the First International Symposium on Innovative Mining Systems held at Massachusetts Institute of Technology, USA 4-5 November 1985, together with some comments on the conclusions and discussion throughout. The Symposium agenda included the following (i) Symposium intentions and expectations; (ii) International; (iii) Developments in safety; (iv) Overview of current major research and trends; (v) Panel discussion: Mechanisms for industrial and international collaboration; (vi) Closing remarks; (vii) Review of innovations: university programs; (viii) Review of selected mine operator programs and needs; Review of equipment innovations; capabilities and trends in areas of mining equipment and robotics; Concurrent sessions: operations and manufacturing. A series of workshops was also held, the titles of which were as follows: (i) Establishment of research network; (ii) Entry development-machine excavation; (iii) Sensing, monitoring, diagnostics, artificial intelligence; (iv) Remote control, automation, mining systems; (v) Computer aided design, simulation, system development; (vi) Surface mining; (vii) Rock breakage.

  8. Survey of special nuclear material vehicle monitors for domestic and international safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Atwater, H.F.; Caldwell, J.T.; Shunk, E.R.

    1979-01-01

    Special nuclear materials vehicle monitors, including gateside vehicle monitors, hand-held personnel-vehicle monitors, and a new tunnel monitor concept for very large vehicles, are discussed. The results of a comparison of effectiveness of monitors for domestic application are presented. The results of calculations and small scale prototype measurements are given for a tunnel-like neutron monitor for monitoring at the perimeter of an enrichment plant subjected to International Safeguards

  9. Advancing internal erosion monitoring using seismic methods in field and laboratory studies

    Science.gov (United States)

    Parekh, Minal L.

    embankment surface. Analysis of root mean squared amplitude and AE threshold counts indicated activity focused at the toe in locations matching the sand boils. This analysis also compared the various detection methods employed at the 2012 test to discuss a timeline of detection related to observable behaviors of the structure. The second area of research included designing and fabricating an instrumented laboratory apparatus for investigating active seismic wave propagation through soil samples. This dissertation includes a description of the rigid wall permeameter, instrumentation, control, and acquisitions systems along with descriptions of the custom-fabricated seismic sensors. A series of experiments (saturated sand, saturated sand with a known static anomaly placed near the center of the sample, and saturated sand with a diminishing anomaly near the center of the sample) indicated that shear wave velocity changes reflected changes in the state of stress of the soil. The mean effective stress was influenced by the applied vertical axial load, the frictional interaction between the soil and permeameter wall, and the degree of preloading. The frictional resistance was sizeable at the sidewall of the permeameter and decreased the mean effective stress with depth. This study also included flow tests to monitor changes in shear wave velocities as the internal erosion process started and developed. Shear wave velocity decreased at voids or lower density zones in the sample and increased as arching redistributes loads, though the two conditions compete. Finally, the social and political contexts surrounding nondestructive inspection were considered. An analogous approach utilized by the aerospace industry was introduced: a case study comparing the path toward adopting nondestructive tools as standard practices in monitoring aircraft safety. Additional lessons for dam and levee safety management were discussed from a Science, Technology, Engineering, and Policy (STEP

  10. The internal model: A study of the relative contribution of proprioception and visual information to failure detection in dynamic systems. [sensitivity of operators versus monitors to failures

    Science.gov (United States)

    Kessel, C.; Wickens, C. D.

    1978-01-01

    The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.

  11. Automated detection and cataloging of global explosive volcanism using the International Monitoring System infrasound network

    Science.gov (United States)

    Matoza, Robin S.; Green, David N.; Le Pichon, Alexis; Shearer, Peter M.; Fee, David; Mialle, Pierrick; Ceranna, Lars

    2017-04-01

    We experiment with a new method to search systematically through multiyear data from the International Monitoring System (IMS) infrasound network to identify explosive volcanic eruption signals originating anywhere on Earth. Detecting, quantifying, and cataloging the global occurrence of explosive volcanism helps toward several goals in Earth sciences and has direct applications in volcanic hazard mitigation. We combine infrasound signal association across multiple stations with source location using a brute-force, grid-search, cross-bearings approach. The algorithm corrects for a background prior rate of coherent unwanted infrasound signals (clutter) in a global grid, without needing to screen array processing detection lists from individual stations prior to association. We develop the algorithm using case studies of explosive eruptions: 2008 Kasatochi, Alaska; 2009 Sarychev Peak, Kurile Islands; and 2010 Eyjafjallajökull, Iceland. We apply the method to global IMS infrasound data from 2005-2010 to construct a preliminary acoustic catalog that emphasizes sustained explosive volcanic activity (long-duration signals or sequences of impulsive transients lasting hours to days). This work represents a step toward the goal of integrating IMS infrasound data products into global volcanic eruption early warning and notification systems. Additionally, a better understanding of volcanic signal detection and location with the IMS helps improve operational event detection, discrimination, and association capabilities.

  12. 4th International Conference on Condition Monitoring of Machinery in Non-Stationary Operations

    CERN Document Server

    Zimroz, Radoslaw; Bartelmus, Walter; Haddar, Mohamed

    2016-01-01

    The book provides readers with a snapshot of recent research and technological trends in the field of condition monitoring of machinery working under a broad range of operating conditions. Each chapter, accepted after a rigorous peer-review process, reports on an original piece of work presented and discussed at the 4th International Conference on Condition Monitoring of Machinery in Non-stationary Operations, CMMNO 2014, held on December 15-16, 2014, in Lyon, France. The contributions have been grouped into three different sections according to the main subfield (signal processing, data mining, or condition monitoring techniques) they are related to. The book includes both theoretical developments as well as a number of industrial case studies, in different areas including, but not limited to: noise and vibration; vibro-acoustic diagnosis; signal processing techniques; diagnostic data analysis; instantaneous speed identification; monitoring and diagnostic systems; and dynamic and fault modeling. This book no...

  13. A component-based system for agricultural drought monitoring by remote sensing.

    Science.gov (United States)

    Dong, Heng; Li, Jun; Yuan, Yanbin; You, Lin; Chen, Chao

    2017-01-01

    In recent decades, various kinds of remote sensing-based drought indexes have been proposed and widely used in the field of drought monitoring. However, the drought-related software and platform development lag behind the theoretical research. The current drought monitoring systems focus mainly on information management and publishing, and cannot implement professional drought monitoring or parameter inversion modelling, especially the models based on multi-dimensional feature space. In view of the above problems, this paper aims at fixing this gap with a component-based system named RSDMS to facilitate the application of drought monitoring by remote sensing. The system is designed and developed based on Component Object Model (COM) to ensure the flexibility and extendibility of modules. RSDMS realizes general image-related functions such as data management, image display, spatial reference management, image processing and analysis, and further provides drought monitoring and evaluation functions based on internal and external models. Finally, China's Ningxia region is selected as the study area to validate the performance of RSDMS. The experimental results show that RSDMS provide an efficient and scalable support to agricultural drought monitoring.

  14. Integrating IPix immersive video surveillance with unattended and remote monitoring (UNARM) systems

    International Nuclear Information System (INIS)

    Michel, K.D.; Klosterbuer, S.F.; Langner, D.C.

    2004-01-01

    Commercially available IPix cameras and software are being researched as a means by which an inspector can be virtually immersed into a nuclear facility. A single IPix camera can provide 360 by 180 degree views with full pan-tilt-zoom capability, and with no moving parts on the camera mount. Immersive video technology can be merged into the current Unattended and Remote Monitoring (UNARM) system, thereby providing an integrated system of monitoring capabilities that tie together radiation, video, isotopic analysis, Global Positioning System (GPS), etc. The integration of the immersive video capability with other monitoring methods already in place provides a significantly enhanced situational awareness to the International Atomic Energy Agency (IAEA) inspectors.

  15. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  16. Levels-of-processing effect on internal source monitoring in schizophrenia.

    Science.gov (United States)

    Ragland, J Daniel; McCarthy, Erin; Bilker, Warren B; Brensinger, Colleen M; Valdez, Jeffrey; Kohler, Christian; Gur, Raquel E; Gur, Ruben C

    2006-05-01

    Recognition can be normalized in schizophrenia by providing patients with semantic organizational strategies through a levels-of-processing (LOP) framework. However, patients may rely primarily on familiarity effects, making recognition less sensitive than source monitoring to the strength of the episodic memory trace. The current study investigates whether providing semantic organizational strategies can also normalize patients' internal source-monitoring performance. Sixteen clinically stable medicated patients with schizophrenia and 15 demographically matched healthy controls were asked to identify the source of remembered words following an LOP-encoding paradigm in which they alternated between processing words on a 'shallow' perceptual versus a 'deep' semantic level. A multinomial analysis provided orthogonal measures of item recognition and source discrimination, and bootstrapping generated variance to allow for parametric analyses. LOP and group effects were tested by contrasting recognition and source-monitoring parameters for words that had been encoded during deep versus shallow processing conditions. As in a previous study there were no group differences in LOP effects on recognition performance, with patients and controls benefiting equally from deep versus shallow processing. Although there were no group differences in internal source monitoring, only controls had significantly better performance for words processed during the deep encoding condition. Patient performance did not correlate with clinical symptoms or medication dose. Providing a deep processing semantic encoding strategy significantly improved patients' recognition performance only. The lack of a significant LOP effect on internal source monitoring in patients may reflect subtle problems in the relational binding of semantic information that are independent of strategic memory processes.

  17. Integrated online condition monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, Hashem M.

    2010-01-01

    Online condition monitoring or online monitoring (OLM) uses data acquired while a nuclear power is operating to continuously assess the health of the plant's sensors, processes, and equipment; to measure the dynamic performance of the plant's process instrumentation; to verify in-situ the calibration of the process instrumentation; to detect blockages, voids, and leaks in the pressure sensing lines; to identify core flow anomalies; to extend the life of neutron detectors and other sensors; and to measure the vibration of reactor internals. Both the steady-state or DC output of plant sensors and their AC signal or noise output can be used to assess sensor health, depending on whether the application is monitoring a rapidly changing (e.g., core barrel motion) or a slowly changing (e.g., sensor calibration) process. The author has designed, developed, installed, and tested OLM systems (comprised of software/hardware-based data acquisition and data processing modules) that integrate low-frequency (1 mHz to 1 Hz) techniques such as RTD cross-calibration, pressure transmitter calibration monitoring, and equipment condition monitoring and high-frequency (1 Hz to 1 kHz) techniques such as the noise analysis technique. The author has demonstrated the noise analysis technique's effectiveness for measuring the dynamic response-time of pressure transmitters and their sensing lines; for performing predictive maintenance on reactor internals; for detecting core flow anomalies; and for extending neutron detector life. Integrated online condition monitoring systems can combine AC and DC data acquisition and signal processing techniques, can use data from existing process sensors during all modes of plant operation, including startup, normal operation, and shutdown; can be retrofitted into existing PWRs, BWRs, and other reactor types and will be integrated into next-generation plants. (orig.)

  18. Integrated online condition monitoring system for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, Hashem M. [Analysis and Measurement Services Corporation, Knoxville, TN (United States). AMS Technology Center

    2010-09-15

    Online condition monitoring or online monitoring (OLM) uses data acquired while a nuclear power is operating to continuously assess the health of the plant's sensors, processes, and equipment; to measure the dynamic performance of the plant's process instrumentation; to verify in-situ the calibration of the process instrumentation; to detect blockages, voids, and leaks in the pressure sensing lines; to identify core flow anomalies; to extend the life of neutron detectors and other sensors; and to measure the vibration of reactor internals. Both the steady-state or DC output of plant sensors and their AC signal or noise output can be used to assess sensor health, depending on whether the application is monitoring a rapidly changing (e.g., core barrel motion) or a slowly changing (e.g., sensor calibration) process. The author has designed, developed, installed, and tested OLM systems (comprised of software/hardware-based data acquisition and data processing modules) that integrate low-frequency (1 mHz to 1 Hz) techniques such as RTD cross-calibration, pressure transmitter calibration monitoring, and equipment condition monitoring and high-frequency (1 Hz to 1 kHz) techniques such as the noise analysis technique. The author has demonstrated the noise analysis technique's effectiveness for measuring the dynamic response-time of pressure transmitters and their sensing lines; for performing predictive maintenance on reactor internals; for detecting core flow anomalies; and for extending neutron detector life. Integrated online condition monitoring systems can combine AC and DC data acquisition and signal processing techniques, can use data from existing process sensors during all modes of plant operation, including startup, normal operation, and shutdown; can be retrofitted into existing PWRs, BWRs, and other reactor types and will be integrated into next-generation plants. (orig.)

  19. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  20. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  1. Individual dose monitoring of occupational exposure in nuclear industry system (1991-2000)

    International Nuclear Information System (INIS)

    Yang Lianzhen; Ma Jizeng; Li Taosheng

    2005-01-01

    The summary and main results of individual dose monitoring (1990-2000) from occupational exposure in China Nuclear Industry System are presented in this paper. During ten years, the external collective effective dose to workers in seven plants (not uranium mines and processing mills) and institutes is 98.48 person ·Sv, the per capita effective dose is 1.97 mSv. The general situation for individual dose monitoring from internal exposure is also introduced. The annual average committed effective dose is less than 5.0 mSv. The individual dose monitoring results (1991-1992) for occupational exposure from Uranium mines and processing mills are depicted. In the end, the individual dose monitoring data in nuclear industry system are preliminarily analysed. (authors)

  2. A component-based system for agricultural drought monitoring by remote sensing.

    Directory of Open Access Journals (Sweden)

    Heng Dong

    Full Text Available In recent decades, various kinds of remote sensing-based drought indexes have been proposed and widely used in the field of drought monitoring. However, the drought-related software and platform development lag behind the theoretical research. The current drought monitoring systems focus mainly on information management and publishing, and cannot implement professional drought monitoring or parameter inversion modelling, especially the models based on multi-dimensional feature space. In view of the above problems, this paper aims at fixing this gap with a component-based system named RSDMS to facilitate the application of drought monitoring by remote sensing. The system is designed and developed based on Component Object Model (COM to ensure the flexibility and extendibility of modules. RSDMS realizes general image-related functions such as data management, image display, spatial reference management, image processing and analysis, and further provides drought monitoring and evaluation functions based on internal and external models. Finally, China's Ningxia region is selected as the study area to validate the performance of RSDMS. The experimental results show that RSDMS provide an efficient and scalable support to agricultural drought monitoring.

  3. Introducing radioactivity monitoring systems in the production of steel

    International Nuclear Information System (INIS)

    Sofilic, T.; Marjanovic, T.; Rastovcan-Mioc, A.

    2005-01-01

    Over the last twenty years, a significant number of cases of radioactive pollution has been recorded in metallurgical processes. However, it is not certain whether the pollution was caused by increased uncontrolled disposal of waste containing radionuclides or whether it was the result of increased radioactivity monitoring and control of metallic scrap. Many metal producers in the world have therefore implemented systematic monitoring of radioactivity in their production processes. Special attention was given to monitoring radioactivity in steel making processes, which is still the most applied construction material with an annual output of over billion tonnes all over the world. Drawing on the experience of the best known steel producers in Europe and world, Croatian steel mills find it necessary and justified to introduce radioactivity monitoring and control systems of radioactive elements in steel scrap, semi-finished and finished products. The aim of this paper is to point out the need to introduce the radioactivity monitoring and control in steel and steel-casting production, and to inform experts in Croatian steel mills and foundries about potential solutions and current systems. At the same time, we wanted to demonstrate how implementation of monitoring equipment can improve quality management and environmental management systems. This would render Croatian products competitive on the European market both in terms of physical and chemical properties and in terms of product quality certificates and radioactivity information. Since we lack our own standards and regulations to control both domestic and imported steel scrap, semi-finished products (crude steel, hot and cold rolled strip) and finished products, we need apply current international recommendations and guidelines, until we design our own monitoring system and adopt relevant legislation on the national level. This paper describes basic types of radioactivity monitoring and control systems, the most

  4. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Science.gov (United States)

    2010-01-01

    ... external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive... 10 Energy 1 2010-01-01 2010-01-01 false Conditions requiring individual monitoring of external and internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR...

  5. Divertor impurity monitor for the International Thermonuclear Experimental Reactor

    Science.gov (United States)

    Sugie, T.; Ogawa, H.; Nishitani, T.; Kasai, S.; Katsunuma, J.; Maruo, M.; Ebisawa, K.; Ando, T.; Kita, Y.

    1999-01-01

    The divertor impurity monitoring system of the International Thermonuclear Experimental Reactor has been designed. The main functions of this system are to identify impurity species and to measure the two-dimensional distributions of the particle influxes in the divertor plasmas. The wavelength range is 200-1000 nm. The viewing fans are realized by molybdenum mirrors located in the divertor cassette. With additional viewing fans seeing through the gap between the divertor cassettes, the region approximately from the divertor leg to the x point will be observed. The light from the divertor region passes through the quartz windows on the divertor port plug and the cryostat, and goes through the dog-leg optics in the biological shield. Three different type of spectrometers: (i) survey spectrometers for impurity species monitoring, (ii) filter spectrometers for the particle influx measurement with the spatial resolution of 10 mm and the time resolution of 1 ms, and (iii) high dispersion spectrometers for high resolution wavelength measurements are designed. These spectrometers are installed just behind the biological shield (for λthe transmission loss in fiber and in the diagnostic room (for λ⩾450 nm) from the point of view of accessibility and flexibility. The optics have been optimized by a ray trace analysis. As a result, 10-15 mm spatial resolution will be achieved in all regions of the divertor.

  6. Development of Cloud-Based UAV Monitoring and Management System.

    Science.gov (United States)

    Itkin, Mason; Kim, Mihui; Park, Younghee

    2016-11-15

    Unmanned aerial vehicles (UAVs) are an emerging technology with the potential to revolutionize commercial industries and the public domain outside of the military. UAVs would be able to speed up rescue and recovery operations from natural disasters and can be used for autonomous delivery systems (e.g., Amazon Prime Air). An increase in the number of active UAV systems in dense urban areas is attributed to an influx of UAV hobbyists and commercial multi-UAV systems. As airspace for UAV flight becomes more limited, it is important to monitor and manage many UAV systems using modern collision avoidance techniques. In this paper, we propose a cloud-based web application that provides real-time flight monitoring and management for UAVs. For each connected UAV, detailed UAV sensor readings from the accelerometer, GPS sensor, ultrasonic sensor and visual position cameras are provided along with status reports from the smaller internal components of UAVs (i.e., motor and battery). The dynamic map overlay visualizes active flight paths and current UAV locations, allowing the user to monitor all aircrafts easily. Our system detects and prevents potential collisions by automatically adjusting UAV flight paths and then alerting users to the change. We develop our proposed system and demonstrate its feasibility and performances through simulation.

  7. Development of Cloud-Based UAV Monitoring and Management System

    Directory of Open Access Journals (Sweden)

    Mason Itkin

    2016-11-01

    Full Text Available Unmanned aerial vehicles (UAVs are an emerging technology with the potential to revolutionize commercial industries and the public domain outside of the military. UAVs would be able to speed up rescue and recovery operations from natural disasters and can be used for autonomous delivery systems (e.g., Amazon Prime Air. An increase in the number of active UAV systems in dense urban areas is attributed to an influx of UAV hobbyists and commercial multi-UAV systems. As airspace for UAV flight becomes more limited, it is important to monitor and manage many UAV systems using modern collision avoidance techniques. In this paper, we propose a cloud-based web application that provides real-time flight monitoring and management for UAVs. For each connected UAV, detailed UAV sensor readings from the accelerometer, GPS sensor, ultrasonic sensor and visual position cameras are provided along with status reports from the smaller internal components of UAVs (i.e., motor and battery. The dynamic map overlay visualizes active flight paths and current UAV locations, allowing the user to monitor all aircrafts easily. Our system detects and prevents potential collisions by automatically adjusting UAV flight paths and then alerting users to the change. We develop our proposed system and demonstrate its feasibility and performances through simulation.

  8. Development of Cloud-Based UAV Monitoring and Management System

    Science.gov (United States)

    Itkin, Mason; Kim, Mihui; Park, Younghee

    2016-01-01

    Unmanned aerial vehicles (UAVs) are an emerging technology with the potential to revolutionize commercial industries and the public domain outside of the military. UAVs would be able to speed up rescue and recovery operations from natural disasters and can be used for autonomous delivery systems (e.g., Amazon Prime Air). An increase in the number of active UAV systems in dense urban areas is attributed to an influx of UAV hobbyists and commercial multi-UAV systems. As airspace for UAV flight becomes more limited, it is important to monitor and manage many UAV systems using modern collision avoidance techniques. In this paper, we propose a cloud-based web application that provides real-time flight monitoring and management for UAVs. For each connected UAV, detailed UAV sensor readings from the accelerometer, GPS sensor, ultrasonic sensor and visual position cameras are provided along with status reports from the smaller internal components of UAVs (i.e., motor and battery). The dynamic map overlay visualizes active flight paths and current UAV locations, allowing the user to monitor all aircrafts easily. Our system detects and prevents potential collisions by automatically adjusting UAV flight paths and then alerting users to the change. We develop our proposed system and demonstrate its feasibility and performances through simulation. PMID:27854267

  9. Individual internal monitoring of workers of Fabrica de Combustivel Nuclear - FCN

    International Nuclear Information System (INIS)

    Castro, Marcelo X.

    2005-01-01

    In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this paper, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. A group of fifteen workers from controlled area of the fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary excretion, faecal excretion, chest counting and personal air sampling (PAS). The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown be the more appropriate methodology for assessing internal dose in this situation. (author)

  10. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  11. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  12. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  13. Successful global assessments and monitoring: The roles of the international community and the United States

    International Nuclear Information System (INIS)

    Lund, H.G.

    1991-01-01

    Successful global assessments and monitoring of natural resources requires teamwork between participating nations and the international communities charged with the responsibility for collecting and disseminating information. In an attempt to identify emerging information needs and to promote coordination, the International Union of Forestry Research Organizations (IUFRO) and other national and international groups held a major conference and workshop in Venice, Italy, on global monitoring last September. The results of the meeting and subsequent events in Montreal indicated a need for more aggressive leadership at the international level and more cooperation at the national level. This paper reports on the outcome of the Venice conference and list some things that the international community and the United States must do to make global assessments and monitoring a reality

  14. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  15. International conference on individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Vanhavere, Filip

    2016-01-01

    This special issue of the journal Radiation Protection Dosimetry is dedicated to the Proceedings of the International Conference on Individual Monitoring of Ionising Radiation (IM2015), which is the fifth of a series of conferences dealing with individual monitoring. This conference series is initiated by EURADOS, the European Radiation Dosimetry Group, and is organised every 5 years. In 2015, the conference was jointly organised by the Belgian Nuclear Research Centre (SCK.CEN), AV Controlatom, and the Vrije Universiteit Brussel. It brought together scientists from regulatory authorities, individual monitoring services (IMS), research bodies, European networks and companies, for the purpose of facilitating the dissemination of knowledge, exchanging experiences and promoting new ideas in the field of individual monitoring. After the conference, 124 papers were submitted for publication in these peer-reviewed proceedings. From these, 103 were finally accepted for publication. The help of the numerous referees and the guest editors is very much appreciated. These proceedings provide a full image of the IM2015 conference. The high-level publications will be useful to improve the state of individual monitoring all over the world and aim to inspire many scientists to continue their work on a better monitoring of radiologically exposed workers

  16. National and international nuclear material monitoring

    International Nuclear Information System (INIS)

    Waddoups, I.G.

    1996-01-01

    The status of nuclear materials in both the U.S. and Former Soviet Union is changing based upon the execution of agreements relative to weapons materials production and weapon dismantlement. The result of these activities is that a considerably different emphasis is being placed on how nuclear materials are viewed and utilized. Even though much effort is being expended on the final disposition of these materials, the interim need for storage and security of the material is increasing. Both safety and security requirements exist to govern activities when these materials are placed in storage. These requirements are intended to provide confidence that the material is not being misused and that the storage operations are conducted safely. Both of these goals can be significantly enhanced if technological monitoring of the material is performed. This paper will briefly discuss the traditional manual methods of U.S. and international material monitoring and then present approaches and technology that are available to achieve the same goals under the evolving environment

  17. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  18. Radiation monitoring system

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  19. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  20. The role of a company’s internal control system in fraud prevention

    Directory of Open Access Journals (Sweden)

    Dragomir Dimitrijevic

    2016-01-01

    Full Text Available The emergence of internal control over specific segments of activities has been associated with management needs for evaluation of the consistency between the actual situation and development targets. Monitoring activities should enable detection and timely reaction to possible target-related deviations. While responding to complex market needs, companies are exposed to numerous internal and external influences, some of which may cause significant damage. Companies have realized that it is safer and cheaper to establish their own internal control systems in order to prevent such influences. The aim of this work is to show how the overall quality of control and The emergence of internal control over specific segments of activities has been associated with management needs for evaluation of the consistency between the actual situation and development targets. Monitoring activities should enable detection and timely reaction to possible target-related deviations. While responding to complex market needs, companies are exposed to numerous internal and external influences, some of which may cause significant damage. Companies have realized that it is safer and cheaper to establish their own internal control systems in order to prevent such influences. The aim of this work is to show how the overall quality of control and company performance is improved through implementation of preventive methods by internal controls, and to indicate that a developed system of internal control represents a protective barrier against various kinds of data manipulation and fraud inside the companies. Special attention was paid to fraud in financial statements since it can cause the most serious damage leading to instability of the economic-financial environment.

  1. Monitoring the Microgravity Environment Quality On-Board the International Space Station Using Soft Computing Techniques

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.

    2001-01-01

    This paper presents an artificial intelligence monitoring system developed by the NASA Glenn Principal Investigator Microgravity Services project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment in time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a graphical display, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, platform structural modes, etc., and decide whether or not to run their experiments based on the acceleration environment associated with a specific event. This monitoring system is focused primarily on detecting the vibratory disturbance sources, but could be used as well to detect some of the transient disturbance sources, depending on the events duration. The system has built-in capability to detect both known and unknown vibratory disturbance sources. Several soft computing techniques such as Kohonen's Self-Organizing Feature Map, Learning Vector Quantization, Back-Propagation Neural Networks, and Fuzzy Logic were used to design the system.

  2. Readout ASIC of pair-monitor for international linear collider

    International Nuclear Information System (INIS)

    Sato, Yutaro; Ikeda, Hirokazu; Ito, Kazutoshi; Miyamoto, Akiya; Nagamine, Tadashi; Sasaki, Rei; Takubo, Yosuke; Tauchi, Toshiaki; Yamamoto, Hitoshi

    2010-01-01

    The pair-monitor is a beam profile monitor at the interaction point of the international linear collider. A prototype of the readout ASIC for the pair-monitor has been designed and tested. Since the pair-monitor uses the hit distribution of electrons and positrons generated by the beam-crossing to measure the beam profile, the readout ASIC is designed to count the number of hits. In a prototype ASIC, 36 readout cells were implemented by TSMC 0.25-μm CMOS process. Each readout cell is equipped with an amplifier, comparator, 8-bit counter and 16 count-registers. By the operation test, all the ASIC component were confirmed to work correctly. As the next step, we develop the prototype ASIC with the silicon on insulator technology. It is produced with OKI 0.2-μm FD-SOI CMOS process.

  3. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  4. BWR control rod drive scram pilot valve monitoring system

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1984-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechancial works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the ''insert'' side of the control rod piston and vents the ''withdraw'' side of the piston causing the rods to insert during a scam. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a ''half scram'', a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  5. A study of penetration test for applying a remote monitoring system for virtual private network

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Park, I. J.; Min, K. S.; Choi, Y. M. [KAERI, Taejon (Korea, Republic of); Jo, D. K. [A3 Security Consulting Co., Seoul (Korea, Republic of)

    2003-07-01

    A penetration test has been performed to verify the vulnerability of Virtual Private Network that is substitute for communication method of an existing remote monitoring system. An existing RMS was used for the private telephone and the RMS was applied of all PWR in Korea. But, due to communication fee, IAEA wanted to replace current telephone line to the internet line to reduce transmission cost in operating remote monitoring system. The communication cost of telephone line was estimated about $66,000/yr. Internet technology would reduce the operating cost up to 1/5. The purpose of the penetration test was to demonstrate the security of the data and system against both various external and internal hacking scenarios. In most cases, hacker could not even identify the VPN system. In any cases, the system did not allow the access of the hacker to the system needless to say the data alteration or system shutdown. Two kinds of test method is chosen; one is external attack and another is internal attack. During the test, the hacking tool was used. The result of test was proved that VPN was secure against internal/external attack.

  6. A study of penetration test for applying a remote monitoring system for virtual private network

    International Nuclear Information System (INIS)

    Kim, J. S.; Kim, J. S.; Park, I. J.; Min, K. S.; Choi, Y. M.; Jo, D. K.

    2003-01-01

    A penetration test has been performed to verify the vulnerability of Virtual Private Network that is substitute for communication method of an existing remote monitoring system. An existing RMS was used for the private telephone and the RMS was applied of all PWR in Korea. But, due to communication fee, IAEA wanted to replace current telephone line to the internet line to reduce transmission cost in operating remote monitoring system. The communication cost of telephone line was estimated about $66,000/yr. Internet technology would reduce the operating cost up to 1/5. The purpose of the penetration test was to demonstrate the security of the data and system against both various external and internal hacking scenarios. In most cases, hacker could not even identify the VPN system. In any cases, the system did not allow the access of the hacker to the system needless to say the data alteration or system shutdown. Two kinds of test method is chosen; one is external attack and another is internal attack. During the test, the hacking tool was used. The result of test was proved that VPN was secure against internal/external attack

  7. Application impact of internal monitoring criteria in radiological protection programs of nuclear medicine services

    International Nuclear Information System (INIS)

    Dantas, Bernardo M.; Dantas, Ana Leticia A.; Juliao, Ligia Q.C.; Lourenco, Maria Cristina; Melo, Dunstana R.

    2005-01-01

    This work presents the simulation of the internal monitoring criteria application for the most used radionuclides by the area of nuclear medicine, taking into consideration the usual conditions of usual source handling and the activity bands authorized by the CNEN. It is concluded that the handling of Iodine 131 for therapeutical purposes is the practice which presents the most risk of internal exposure for the works, requiring the adoption of a program for internal monitoring by the nuclear medicine services

  8. AUTOMATED PROCESS MONITORING: APPLYING PROVEN AUTOMATION TECHNIQUES TO INTERNATIONAL SAFEGUARDS NEEDS

    International Nuclear Information System (INIS)

    O'Hara, Matthew J.; Durst, Philip C.; Grate, Jay W.; Devol, Timothy A.; Egorov, Oleg; Clements, John P.

    2008-01-01

    Identification and quantification of specific alpha- and beta-emitting radionuclides in complex liquid matrices is highly challenging, and is typically accomplished through laborious wet chemical sample preparation and separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, gas proportional counting, alpha energy analysis, mass spectrometry). Analytical results may take days or weeks to report. Chains of custody and sample security measures may also complicate or slow the analytical process. When an industrial process-scale plant requires the monitoring of specific radionuclides as an indication of the composition of its feed stream or of plant performance, radiochemical measurements must be fast, accurate, and reliable. Scientists at Pacific Northwest National Laboratory have assembled a fully automated prototype Process Monitor instrument capable of a variety of tasks: automated sampling directly from a feed stream, sample digestion/analyte redox adjustment, chemical separations, radiochemical detection and data analysis/reporting. The system is compact, its components are fluidically inter-linked, and analytical results could be immediately transmitted to on- or off-site locations. The development of a rapid radiochemical Process Monitor for 99Tc in Hanford tank waste processing streams, capable of performing several measurements per hour, will be discussed in detail. More recently, the automated platform was modified to perform measurements of 90Sr in Hanford tank waste stimulant. The system exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs

  9. Data monitoring system of technical diagnosis system for EAST

    International Nuclear Information System (INIS)

    Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong

    2010-01-01

    Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)

  10. Real-Time System Supervision for the LHC Beam Loss Monitoring System at CERN

    CERN Document Server

    Zamantzas, C; Effinger, E; Emery, J; Jackson, S

    2014-01-01

    The strategy for machine protection and quench prevention of the Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is mainly based on the Beam Loss Monitoring (BLM) system. The LHC BLM system is one of the most complex and large instrumentation systems deployed in the LHC. In addition to protecting the collider, the system also needs to provide a means of diagnosing machine faults and deliver feedback of the losses to the control room as well as to several systems for their setup and analysis. In order to augment the dependability of the system several layers of supervision has been implemented internally and externally to the system. This paper describes the different methods employed to achieve the expected availability and system fault detection.

  11. The JOYO remote monitoring system

    International Nuclear Information System (INIS)

    Damico, Joseph P.; Hashimoto, Yu

    2000-01-01

    The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)

  12. Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis

    Science.gov (United States)

    Chen, Wen; Tang, Ming

    2017-04-01

    The abnormal temperature rise is the precursor of the defective composite insulator in power transmission line. However no consolidated techniques or methodologies can on line monitor its internal temperature now. Thus a new method using embedding fiber Bragg grating (FBG) in fiber reinforced polymer (FRP) rod is adopted to monitor its internal temperature. To correctly demodulate the internal temperature of FRP rod from the Bragg wavelength shift of FBG, the conversion coefficient between them is deduced theoretically based on comprehensive investigation on the thermal stresses of the metal-composite joint, as well as its material and structural properties. Theoretical model shows that the conversion coefficients of FBG embedded in different positions will be different because of non-uniform thermal stress distribution, which is verified by an experiment. This work lays the theoretical foundation of monitoring the internal temperature of composite insulator with embedding FBG, which is of great importance to its health structural monitoring, especially early diagnosis.

  13. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    Results are presented of internal contamination surveys carried out since 1969 at Tokai Research Establishment. Routine monitoring sometimes revealed significant internal contamination for tritium workers, but almost never for others. The number of subjects for special monitoring varied according to the activities. In 1965, the number of subjects for special monitoring was nearly 300, due to a reactor repair that year. In recent years, the number or special monitoring has been several tens or so. With regard to special monitoring, the workers with significant internal contamination were less than 50%. The internal dose (50 years) estimated for the majority of subjects was of mrem order. During the past 15 years, only several cases of exposure of rem order were found. The highest dose experienced was about 4 rems ( 131 I thyroid) (U.K.)

  14. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  15. A comparison of internal versus external risk-adjustment for monitoring clinical outcomes

    NARCIS (Netherlands)

    Koetsier, Antonie; de Keizer, Nicolette; Peek, Niels

    2011-01-01

    Internal and external prognostic models can be used to calculate severity of illness adjusted mortality risks. However, it is unclear what the consequences are of using an external model instead of an internal model when monitoring an institution's clinical performance. Theoretically, using an

  16. Experimental investigation of leak detection using mobile distributed monitoring system

    Science.gov (United States)

    Chen, Jiang; Zheng, Junli; Xiong, Feng; Ge, Qi; Yan, Qixiang; Cheng, Fei

    2018-01-01

    The leak detection of rockfill dams is currently hindered by spatial and temporal randomness and wide monitoring range. The spatial resolution of fiber Bragg grating (FBG) temperature sensing technology is related to the distance between measuring points. As a result, the number of measuring points should be increased to ensure that the precise location of the leak is detected. However, this leads to a higher monitoring cost. Consequently, it is difficult to promote and apply this technology to effectively monitor rockfill dam leakage. In this paper, a practical mobile distributed monitoring system with dual-tubes is used by combining the FBG sensing system and hydrothermal cycling system. This dual-tube structure is composed of an outer polyethylene of raised temperature resistance heating pipe, an inner polytetrafluoroethylene tube, and a FBG sensor string, among which, the FBG sensor string can be dragged freely in the internal tube to change the position of the measuring points and improve the spatial resolution. In order to test the effectiveness of the system, the large-scale model test of concentrated leakage in 13 working conditions is carried out by identifying the location, quantity, and leakage rate of leakage passage. Based on Newton’s law of cooling, the leakage state is identified using the seepage identification index ζ v that was confirmed according to the cooling curve. Results suggested that the monitoring system shows high sensitivity and can improve the spatial resolution with limited measuring points, and thus better locate the leakage area. In addition, the seepage identification index ζ v correlated well with the leakage rate qualitatively.

  17. The stages of the international drug control system.

    Science.gov (United States)

    Carstairs, Catherine

    2005-01-01

    This paper argues that the history of the international drug control system of the League of Nations/United Nations can be divided into three cumulative stages. The first stage, the supply stage, dates back to early part of the 20th century, and aimed to reduce the supply of drugs through careful monitoring and trade regulations. This has remained the dominant control strategy. In the middle of the century, demand control, in the form of treatment and criminalization of the individual user, began to appear. This was the least successful stage. Finally, in the 1980s, the dangers of the drug traffic assumed an important place on the international agenda and measures to reduce drug-related organized crime were enacted. To date, this has been a process of proliferation of regulatory strategies. Recently, new challenges to the international drug control system have emerged, including well-funded non-governmental organizations critical of the war on drugs, and the adoption of harm reduction measures in national policies around the world.

  18. Modern integrated environmental monitoring and processing systems for nuclear facilities

    International Nuclear Information System (INIS)

    Oprea, I.

    2000-01-01

    presentation by using on-line dynamic evolution of the events, environment information, evacuation optimization, image and voice processing. These modern systems are proposed for environmental monitoring around nuclear facilities, as open interactive systems supporting the operator in the global overview of the environment and the status of the situation updating the remote GIS data base, assuring man-computer interaction and a good information flow for emergency knowledge exchange, improving the protection of the population and decision makers efforts. The local monitoring systems could be integrated into national or international environmental monitoring systems, achieving desired interoperability between government, civilian and army in disaster preparedness efforts

  19. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  20. Performance Management and Monitoring of Internal Audit for the Public Sector in Romania

    Directory of Open Access Journals (Sweden)

    Elena Doina Dascălu

    2016-08-01

    Full Text Available Performance management is an on-going process, which has an essential component part, performance measurement, which involves the identification, supervision and communication of performance results, through the relation to a set of performance indicators. Based on the assessment results, corrective measures are established to ensure attainment of targeted results, offering a feedback, essential for the decision grounding enhancement, at all levels: strategic, operational or individual. As concerns performance management in public institutions in Romania, The Code on managerial internal control provides a hierarchy type model, in the framework of which, the head of the public entity, which is on the first level, needs to provide for performance monitoring for each objective and activity, through the intermediary of relevant quantitative and qualitative indicators, including referring to economy, efficiency, and effectiveness. Given the importance of the internal audit in the process of performance management, identifying solutions for continuous improvement of the public internal audit was subject to a study that was based on questioning public sector auditors on how to monitor the performance of public internal audit activity. Considering issues arising, the article proposes a series of directions for improving the monitoring of the performance of public internal audit activity in the public sector.

  1. Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Laurence [Georgia Inst. of Technology, Atlanta, GA (United States); Kim, Jin-Yeon [Georgia Inst. of Technology, Atlanta, GA (United States); Qu, Jisnmin [Northwestern Univ., Evanston, IL (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wall, Joe [Electric Power Research Inst. (EPRI), Knoxville, TN (United States)

    2015-11-02

    The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor – a sensor that can continuously monitor a material’s damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks: (1

  2. Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

    International Nuclear Information System (INIS)

    Jacobs, Laurence; Kim, Jin-Yeon; Qu, Jisnmin; Ramuhalli, Pradeep; Wall, Joe

    2015-01-01

    The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor - a sensor that can continuously monitor a material's damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks

  3. Proceedings of the international workshop on monitoring forest degradation in Southeast Asia

    Science.gov (United States)

    Leif A. Mortenson; James J. Halperin; Patricia N. Manley; Rich L. Turner

    2013-01-01

    The international workshop on monitoring forest degradation in Southeast Asia provided a forum for discussion of the technical, social and political challenges and successes that have occurred during recent work in sub-national forest degradation monitoring. The 2012 workshop, held in Bangkok, Thailand, followed recent US Forest Service/LEAF (USAID's Lowering...

  4. Internal dosimetry monitoring equipment: Present and future

    International Nuclear Information System (INIS)

    Selby, J.; Carbaugh, E.H.; Lynch, T.P.; Strom, D.J.; Lardy, M.M.

    1993-09-01

    We have attempted to characterize the current and future status of in vivo and in vitro measurement programs coupled with the associated radioanalytical methods and workplace monitoring. Developments in these areas must be carefully integrated by internal dosimetrists, radiochemists and field health physicists. Their goal should be uniform improvement rather than to focus on one specific area (e.g., dose modeling) to the neglect of other areas where the measurement capabilities are substantially less sophisticated and, therefore, the potential source of error is greatest

  5. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  6. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  7. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  8. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  9. Limb defects associated with major congenital anomalies : Clinical and epidemiological study from the international clearinghouse for birth defects monitoring systems

    NARCIS (Netherlands)

    Rosano, A; Botto, LD; Olney, RS; Khoury, MJ; Ritvanen, A; Goujard, J; Stoll, C; Cocchi, G; Merlob, P; Mutchinick, O; Cornel, MC; Castilla, EE; Martinez-Frias, ML; Zampino, G; Erickson, JD; Mastroiacovo, P

    2000-01-01

    Although limb defects associated with other congenital anomalies are rarely studied, they may provide insights into limb development that may be useful for etiologic studies and public health monitoring, me pooled data from II birth defect registries that are part of the International Clearinghouse

  10. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  11. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  12. Synthesizing International Understanding of Changes in the Arctic Hydrological System

    Science.gov (United States)

    Pundsack, J. W.; Vorosmarty, C. J.; Hinzman, L. D.

    2009-12-01

    There are several notable gaps in our current level of understanding of Arctic hydrological systems. At the same time, rapidly emerging data sets, technologies, and modeling resources provide us with an unprecedented opportunity to move substantially forward. The Arctic Community-Wide Hydrological Analysis and Monitoring Program (Arctic-CHAMP), funded by NSF/ARCSS, was established to initiate a major effort to improve our current monitoring of water cycle variables, and to foster collaboration with the many relevant U.S. and international arctic research initiatives. These projects, funded under ARCSS through the ‘Freshwater Integration (FWI) study’, links CHAMP, the Arctic/Subarctic Ocean Fluxes (ASOF) Programme, and SEARCH. As part of the overall synthesis and integration efforts of the NSF-ARCSS Freshwater Integration (FWI) study, the program carried-out a major International Synthesis Capstone Workshop in Fall 2009 as an International Polar Year (IPY) affiliated meeting. The workshop, "Synthesizing International Understanding of Changes in the Arctic Hydrological System,” was held 30 September to 4 October 2009 in Stockholm at the Beijer Auditorium of the Royal Swedish Academy. The workshop was sponsored by the NSF-ARCSS Arctic-CHAMP Science Management Office (City College of New York / Univ. of New Hampshire), the International Study of Arctic Change (ISAC), and the International Arctic Research Center (IARC; Univ. of Alaska Fairbanks). The overarching goals of the meeting were to stage a post-IPY lessons-learned workshop with co-equal numbers of FWI, IPY, and ICARP-II researchers, using insights from recent scientific findings, data, and strategies to afford synthesis. The workshop aimed to: (1) take stock of recent advances in our understanding of changes in the Arctic hydrological system; (2) identify key remaining research gaps / unanswered questions; and (3) gather insight on where to focus future research efforts/initiatives (nationally and

  13. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  14. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  15. Monitoring requirements for assessment of internal dose

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1985-01-01

    Data obtained by routine personnel monitoring is usually not a sufficient basis for estimation of dose. Collected data must be interpreted carefully and supplemented with appropriate information before reasonably accurate estimates of dose (i.e., accurate enough to indicate whether or nor personnel are exposed in excess of recommended limits) can be developed. When the exposure is of sufficient magnitude that a rather precise estimate of dose is needed, the health physicist will bring to bear on the problem other, more refined, methods of dosimetry. These might include a reconstruction of the incident and, for internal emitters, an extensive series of in vivo measurements or analyses of excreta. Thus, cases of special significance must often be evaluated using techniques and resources beyond those routinely employed. This is not a criticism of most routine monitoring programs. These programs are usually carefully designed in a manner commensurate with the degree of exposure routinely encountered and the requirement of a practical program of radiation protection. 10 refs

  16. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  17. Selected nondestructive assay instrumentation for an international safeguards system at uranium enrichment plants

    International Nuclear Information System (INIS)

    Tape, J.W.; Baker, M.P.; Strittmatter, R.; Jain, M.; Evans, M.L.

    1979-01-01

    A selected set of nondestructive assay instruments for an international safeguards system at uranium enrichment plants is currently under development. These instruments are of three types: in-line enrichment meters for feed, product, and tails streams; area radiation monitors for direct detection of high-enriched uranium production, and an enrichment meter for spent alumina trap material. The current status of the development of each of these instruments is discussed, with supporting data, as well as the role each would play in a total international safeguards system. 5 figures

  18. USAID Colombia - Clearinghouse Monitor

    Data.gov (United States)

    US Agency for International Development — The Monitoring and Evaluation (M&E) Clearinghouse-Monitor is a web-based Information System that provides the Mission with information about the status and...

  19. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  20. Design and Realization of Online Monitoring System of Distributed New Energy and Renewable Energy

    Science.gov (United States)

    Tang, Yanfen; Zhou, Tao; Li, Mengwen; Zheng, Guotai; Li, Hao

    2018-01-01

    Aimed at difficult centralized monitoring and management of current distributed new energy and renewable energy generation projects due to great varieties, different communication protocols and large-scale difference, this paper designs a online monitoring system of new energy and renewable energy characterized by distributed deployment, tailorable functions, extendible applications and fault self-healing performance. This system is designed based on international general standard for grid information data model, formulates unified data acquisition and transmission standard for different types of new energy and renewable energy generation projects, and can realize unified data acquisition and real-time monitoring of new energy and renewable energy generation projects, such as solar energy, wind power, biomass energy, etc. within its jurisdiction. This system has applied in Beijing. At present, 576 projects are connected to the system. Good effect is achieved and stability and reliability of the system have been validated.

  1. A Modernized System for Agricultural Monitoring for Food Security in Tanzania

    Science.gov (United States)

    Dempewolf, J.; Nakalembe, C. L.; Becker-Reshef, I.; Justice, C. J.; Tumbo, S.; Mbilinyi, B.; Maurice, S.; Mtalo, M.

    2016-12-01

    Accurate and timely information on agriculture, particularly in many countries dominated by complex smallholder, subsistence agricultural systems is often difficult to obtain or not available. This includes up-to-date information during the growing season on crop type, crop area and crop condition such as developmental stage, damage from pests and diseases, drought or flooding. These data are critical for government decision making on production forecasts, planning for commodity market transactions, food aid delivery, responding to disease outbreaks and for implementing agricultural extension and development efforts. In Tanzania we have been working closely with the National Food Security Division (NFSD) at the Ministry of Agriculture, Livestock and Fisheries (MALF) on designing and implementing an advanced agricultural monitoring system, utilizing satellite remote sensing, smart phone and internet technologies. Together with our local implementing partner, the Sokoine University of Agriculture we trained a large number of agricultural extension agents in different regions of Tanzania to deliver field data in near-realtime. Using our collaborative internet portal (Crop Monitor) the team of analysts compiles pertinent information on current crop and weather conditions from throughout the country in a standardized, consistent manner. Using the portal traditionally collected data are combined with electronically collected field data and MODIS satellite image time series from GLAM East-Africa (Global Agricultural Monitoring System, customized for stakeholders in East Africa). The main outcome of this work has been the compilation of the National Food Security Bulletin for Tanzania with plans for a public release and the intention for it to become the main avenue to dispense current updates and analysis on agriculture in the country. The same information is also a potential contribution to the international Early Warning Crop Monitor, which currently covers Tanzania

  2. The Program for Regional and International Shorebird Monitoring (PRISM)

    Science.gov (United States)

    Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.; Morrison, R.I.G.; Skagen, S.K.

    2005-01-01

    This report describes the "Program for Regional and International Shorebird Monitoring" (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird conservation plans recently completed in Canada and the United States. The goals of PRISM are to (1) estimate the size of breeding population of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for each of these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. PRISM has four main components: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-breeding surveys, and neotropical surveys. Progress on, and action items for, each major component are described. The more important major tasks for immediate action are carrying out the northern surveys, conducting regional analyses to design the program of migration counts, and evaluating aerial photographic surveys for migration and winter counts.

  3. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  4. Radiation monitor system for nuclear power plants

    International Nuclear Information System (INIS)

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  5. General technical requirements (GTR) for inventory monitoring systems (IMS) for the trilateral initiative

    International Nuclear Information System (INIS)

    Pshakin, Gennady M.; Kuleshov, I.; Shea, T.; Puckett, J.M.; Zhukov, I.; Mangan, Dennis L.; Matter, John C.; Waddoups, I.; Smathers, D.; Abhold, M.E.; Hsue, S.-T.; Chiaro, P.

    2002-01-01

    Pursuant to the Trilateral Initiative, the three parties (The Russian Federation, the United States, and the International Atomic Energy Agency) have been engaged in discussions concerning the structure of reliable monitoring systems for storage facilities having large inventories. The intent of these monitoring systems is to provide the capability for the IAEA to maintain continuity of knowledge in a sufficiently reliable manner that should there be equipment failure, loss of continuity of knowledge would be restricted to a small population of the inventory, and thus reinventory of the stored items would be minimized These facility-specific monitoring systems, referred to as Inventory Monitoring Systems (IMS) are to provide the principal means for the M A to assure that the containers of fissile material remain accounted under the Verification Agreements which are to be concluded between the IAEA and the Russian Federation and the lAEA and the United States for the verification of weapon-origin and other fissile material specified by each State as released from its defense programs. A technical experts working group for inventory monitoring systems has been meeting since Feb- of 2000 to formulate General Technical Requirements (GTR) for Inventory Monitoring Systems for the Trilateral Initiative. Although provisional agreement has been reached by the three parties concerning the GTR, it is considered a living document that can be updated as warranted by the three parties. This paper provides a summary of the GTR as it currently exists.

  6. Ninth International Conference on Dependability and Complex Systems

    CERN Document Server

    Mazurkiewicz, Jacek; Sugier, Jarosław; Walkowiak, Tomasz; Kacprzyk, Janusz

    2014-01-01

    DepCoS – RELCOMEX is an annual series of conferences organized by Wrocław University of Technology to promote a comprehensive approach to evaluation of system performability which is now commonly called dependability. In contrast to classic analyses which were concentrated on reliability of technical resources and structures built from them, dependability is based on multi-disciplinary approach to theory, technology, and maintenance of a system considered to be a multifaceted amalgamation of technical, information, organization, software and human (users, administrators, supervisors, etc.) resources. Diversity of processes being realized (data processing, system management, system monitoring, etc.), their concurrency and their reliance on in-system intelligence often severely impedes construction of strict mathematical models and calls for application of intelligent and soft computing methods. This book presents the proceedings of the Ninth International Conference on Dependability and Complex Systems DepC...

  7. Lateralization of the posterior parietal cortex for internal monitoring of self- versus externally generated movements.

    Science.gov (United States)

    Ogawa, Kenji; Inui, Toshio

    2007-11-01

    Internal monitoring or state estimation of movements is essential for human motor control to compensate for inherent delays and noise in sensorimotor loops. Two types of internal estimation of movements exist: self-generated movements, and externally generated movements. We used functional magnetic resonance imaging to investigate differences in brain activity for internal monitoring of self- versus externally generated movements during visual occlusion. Participants tracked a sinusoidally moving target with a mouse cursor. On some trials, vision of either target (externally generated) or cursor (self-generated) movement was transiently occluded, during which subjects continued tracking by estimating current position of either the invisible target or cursor on screen. Analysis revealed that both occlusion conditions were associated with increased activity in the presupplementary motor area and decreased activity in the right lateral occipital cortex compared to a control condition with no occlusion. Moreover, the right and left posterior parietal cortex (PPC) showed greater activation during occlusion of target and cursor movements, respectively. This study suggests lateralization of the PPC for internal monitoring of internally versus externally generated movements, fully consistent with previously reported clinical findings.

  8. MPC and A operational monitoring system pilot project at MEPhI as example of successful application in the international/national control and guaranties programs

    International Nuclear Information System (INIS)

    Ryzhukhin, D.V.; Bondarev, P.V.; Pogozhin, N.S.

    2002-01-01

    Full text: At present an active development of digital communication technologies has resulted in reduction of their cost and increase of their possibilities. As a result the remote monitoring systems gain new development. The increase of the requirements to a safety level on potentially dangerous and very important objects makes such systems extremely attractive for using in a system of national departmental or international control and inspections. Purpose of using such systems is to provide control for correctness of subject to the control-regulated procedures performance, performance of management or inspection bodies' instructions and operating of existing protection systems, at integration with them. This control is independent from object staff. The remote monitoring systems usage by supervising bodies at an object gives following advantages: timely reception of information; increase of information volume at the expense of constant non physically presence of an onsite inspector; increase of received information objectivity at the expense of the fact of 'undeclared inspections' realization; an opportunity of application modern information technologies for analysis and storage of digital information; reduction of impact on object's work; reduction of volume of physical inspections and expenses for their realization. All above was reflected in the material protect, control and accounting (MPC and A) operational monitoring (MOM) program, begun under Russian-American cooperation in the field of MPC and A in 2001. MOM program purpose is to control double application materials and radioactive divided materials, activity of the people under MPC and A program and procedures ensuring performance of guarantees on special nuclear material (SNM) protection and non-proliferation. The Moscow engineering-physics institute (state university) (MEPhl) was chosen as an object of realization of MOM system pilot project. The reasons are that MEPhl is installed under framework of

  9. Evaluating the Level of Internal Control System in the Management of Financial Security of Bank

    Directory of Open Access Journals (Sweden)

    Pidvysotska Lyudmyla J.

    2017-06-01

    Full Text Available The article is aimed at studying the organization and technology of evaluation process of the internal control system of bank in order to ensure financial security management of its activities. The work of the internal audit service on monitoring and evaluating the performance of the bank’s internal control system was analyzed. It has been found that improving the level of financial security of commercial banks is conditional upon improvements in the quality of audits and the provision of sound and objective conclusions. The interrelation of the tasks of internal audit service and the tasks of bank’s financial security management has been determined. Methodological recommendations on evaluation of the bank’s internal control system on the basis of results of audit have been proposed.

  10. Annual Forest Monitoring as part of Indonesia's National Carbon Accounting System

    Science.gov (United States)

    Kustiyo, K.; Roswintiarti, O.; Tjahjaningsih, A.; Dewanti, R.; Furby, S.; Wallace, J.

    2015-04-01

    Land use and forest change, in particular deforestation, have contributed the largest proportion of Indonesia's estimated greenhouse gas emissions. Indonesia's remaining forests store globally significant carbon stocks, as well as biodiversity values. In 2010, the Government of Indonesia entered into a REDD+ partnership. A spatially detailed monitoring and reporting system for forest change which is national and operating in Indonesia is required for participation in such programs, as well as for national policy reasons including Monitoring, Reporting, and Verification (MRV), carbon accounting, and land-use and policy information. Indonesia's National Carbon Accounting System (INCAS) has been designed to meet national and international policy requirements. The INCAS remote sensing program is producing spatially-detailed annual wall-to-wall monitoring of forest cover changes from time-series Landsat imagery for the whole of Indonesia from 2000 to the present day. Work on the program commenced in 2009, under the Indonesia-Australia Forest Carbon Partnership. A principal objective was to build an operational system in Indonesia through transfer of knowledge and experience, from Australia's National Carbon Accounting System, and adaptation of this experience to Indonesia's requirements and conditions. A semi-automated system of image pre-processing (ortho-rectification, calibration, cloud masking and mosaicing) and forest extent and change mapping (supervised classification of a 'base' year, semi-automated single-year classifications and classification within a multi-temporal probabilistic framework) was developed for Landsat 5 TM and Landsat 7 ETM+. Particular attention is paid to the accuracy of each step in the processing. With the advent of Landsat 8 data and parallel development of processing capability, capacity and international collaborations within the LAPAN Data Centre this processing is being increasingly automated. Research is continuing into improved

  11. A Grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  12. A grid job monitoring system

    International Nuclear Information System (INIS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  13. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  14. Atomics International environmental monitoring and facility effluent annual report, 1976

    International Nuclear Information System (INIS)

    Moore, J.D.

    1977-01-01

    Environmental and facility effluent radioactivity monitoring at Atomics International (AI) is performend by the Radiation and Nuclear Safety Unit of the Health, Safety, and Radiation Services Department. Soil, vegetation, and surface water are routinely sampled to a distance of 10 miles from AI sites. Continuous ambient air sampling and thermoluminescent dosimetry are performed on site for monitoring airborne radioactivity and site ambient radiation levels. Radioactivity in effluents discharged to the atmosphere from AI facilities is continuously sampled and monitored to ensure that levels released to unrestricted areas are within appropriate limits, and to identify processes which may require additional engineering safeguards to minimize radioactivity levels in such effluents. In addition, selected nonradioactive constituents in surface water discharged to unrestricted areas are determined. This report summarizes and discusses monitoring results for 1976. The results of a special soil plutonium survey performed during the year are also summarized

  15. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  16. MONITORING OF INTERNATIONAL DONOR ASSISTANCE IN THE CONTEXT OF THE DEVELOPMENT OF AMALGAMATED TERRITORIAL COMMUNITIES

    Directory of Open Access Journals (Sweden)

    Elina Boichenko

    2017-12-01

    Full Text Available The research is conducted within the framework of the joint project of the F. Ebert Foundation (Germany and the Institute of Economic and Legal Studies of the National Academy of Sciences of Ukraine (Ukraine “The Experience of the Association of Territorial Communities in Eastern Ukraine: Economic and Legal Aspects”. The subject of the study is the theoretical, methodological, and practical aspects of monitoring international donor assistance in the context of the development of amalgamated territorial communities (ATC based on the example of Bilokurakyne and Novopskov ATC. Methodology. The system approach (in substantiating the directions of monitoring and established procedures for monitoring each component of the life of amalgamated territorial communities, logical generalization (in determining the state of development of amalgamated territorial communities, method of absolute, relative, and mean values, analysis of the dynamics series and structural shifts (in determining the dominant trends in the formation and development of ATC, method of economic analysis and synthesis (in determining the content of the monitoring, method of comparison (when the violations in the process of ATC, graphical method (the construction algorithm combined operation and development of local communities imaging method (for presenting the results of the total amount of international aid to ATC are used in the work. The purpose of the research is to develop theoretical, methodological, and practical approaches to the monitoring of international donor assistance in the context of the development of amalgamated territorial communities. The article suggests using monitoring as the most effective tool for controlling economic and social phenomena and processes. The authorial scheme for constructing a procedure for the monitoring of functioning and development of amalgamated territorial communities is developed. The monitoring of international donor support of the

  17. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  18. GTA Beamloss-Monitor System

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper

  19. GTA beamloss-monitor system

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref

  20. Wireless remote radiation monitoring system (WRRMS). Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The Science Application International Corporation (SAIC) RadStar trademark wireless remote radiation monitoring system (WRRMS) is designed to provide real-time monitoring of the radiation dose to workers as they perform work in radiologically contaminated areas. WRRMS can also monitor dose rates in a room or area. The system uses radio-frequency communications to transmit dose readings from the wireless dosimeters worn by workers to a remote monitoring station that can be located out of the contaminated area. Each base station can monitor up to 16 workers simultaneously. The WRRMS can be preset to trigger both audible and visual alarms at certain dose rates. The alarms are provided to the worker as well as the base station operator. This system is particularly useful when workers are wearing personal protective clothing or respirators that make visual observation of their self-reading dosimeters (SRDs), which are typically used to monitor workers, more difficult. The base station is an IBM-compatible personal computer that updates and records information on individual workers every ten seconds. Although the equipment costs for this improved technology are higher than the SRDs (amortized at $2.54/hr versus $1.02/hr), total operational costs are actually less ($639/day versus $851/day). This is because the WRRMS requires fewer workers to be in the contaminated zone than the traditional (baseline) technology. There are also intangible benefits associated with improved worker safety and as low as reasonably achievable (ALARA) principles, making the WRRMS an attractive alternative to the baseline technology. The baseline technology measures only integrated dose and requires workers to check their own dosimeters manually during the task

  1. Wireless remote radiation monitoring system (WRRMS). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1998-12-01

    The Science Application International Corporation (SAIC) RadStar{trademark} wireless remote radiation monitoring system (WRRMS) is designed to provide real-time monitoring of the radiation dose to workers as they perform work in radiologically contaminated areas. WRRMS can also monitor dose rates in a room or area. The system uses radio-frequency communications to transmit dose readings from the wireless dosimeters worn by workers to a remote monitoring station that can be located out of the contaminated area. Each base station can monitor up to 16 workers simultaneously. The WRRMS can be preset to trigger both audible and visual alarms at certain dose rates. The alarms are provided to the worker as well as the base station operator. This system is particularly useful when workers are wearing personal protective clothing or respirators that make visual observation of their self-reading dosimeters (SRDs), which are typically used to monitor workers, more difficult. The base station is an IBM-compatible personal computer that updates and records information on individual workers every ten seconds. Although the equipment costs for this improved technology are higher than the SRDs (amortized at $2.54/hr versus $1.02/hr), total operational costs are actually less ($639/day versus $851/day). This is because the WRRMS requires fewer workers to be in the contaminated zone than the traditional (baseline) technology. There are also intangible benefits associated with improved worker safety and as low as reasonably achievable (ALARA) principles, making the WRRMS an attractive alternative to the baseline technology. The baseline technology measures only integrated dose and requires workers to check their own dosimeters manually during the task.

  2. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  3. Design of a control system for HIRFL-CSRe internal target facility in Lanzhou

    International Nuclear Information System (INIS)

    Wang Yanyu; Liu Wufeng; Shao Caojie; Lin Feiyu; Zhang Jianchuan; Xiao Wenjun

    2010-01-01

    It is described in this paper the design of the control system for HIRFL-CSRe internal target facility, in which there are many different kinds of units need to be monitored and controlled. The control system is composed of several subsystems which are designed to control the gas-jet temperature, chamber vacuum, valves and molecular pumps. A human-computer interaction interface is also realized to do the data acquisition, data processing and display. The whole system has been working stably and safely, it fully meets the requirements of physical experiments in the internal target facility. In January of 2010, the first physics experiment of the radioactive electron capture was finished successfully with the aids of this control system. (authors)

  4. Implementation of internal monitoring programs for workers occupationally exposed by 131I in nuclear medicine services in Brazil

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2017-01-01

    In nuclear medicine services (NMS), workers routinely handle radionuclides for diagnostic and therapy. This practice represents a risk of incorporation by these radionuclides. The International Atomic Energy Agency (IAEA) recommends the implementation of an internal monitoring program on workers exposed to annual effective doses greater than 1 mSv, as for example, those who handle 131 I for therapy in NMS. Currently, in Brazil, there are not enough available laboratories qualified to provide internal monitoring services to attend all possible demand of internal monitoring if it such regulation were applied by the Brazilian Nuclear Regulatory Board (CNEN). The objective of this work is to disseminate simple and inexpensive methods for in vivo routine thyroid monitoring of 131 I using equipment available in the NMS. Devices available in two public hospitals located in the city of Rio de Janeiro were calibrated for use in occupational internal monitoring. The equipment evaluated in this work presented enough sensitivity for such application, being suitable to access intakes of 131 I in the thyroid and able to estimate doses below 1 mSv. (author)

  5. Radiation protection - Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material

    International Nuclear Information System (INIS)

    2006-01-01

    In the course of employment, individuals might work with radioactive materials that, under certain circumstances, could be taken into the body. Protecting workers against risks of incorporated radionuclides requires the monitoring of potential intakes and/or the quantification of actual intakes and exposures. The selection of measures and programmes for this purpose requires decisions concerning methods, techniques, frequencies etc. for measurements and dose assessment. The criteria permitting the evaluation of the necessity of such a monitoring programme or for the selection of methods and frequencies of monitoring usually depend upon the legislation, the purpose of the radiation protection programme, the probabilities of potential radionuclide intakes, and the characteristics of the materials handled. This International Standard offers guidance for the decision whether a monitoring programme is required and how it should be designed. Its intention is to optimise the efforts for such a monitoring programme consistent with legal requirements and with the purpose of the radiation protection programme. Recommendations of international expert bodies and international experience with the practical application of these recommendations in radiation protection programmes have been considered in the development of this International Standard. Its application facilitates the exchanges of information between authorities, supervisory institutions and employers. The International Standard is not a substitute for legal requirements. In the International Standard, the word 'shall' is used to denote a requirement and no deviation is allowed. The word 'should' is used to denote a recommendation from which justified deviations are allowed. The word 'may' is used to denote permission

  6. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  7. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  8. Radiological safety system based on real-time tritium-in-air monitoring indoor and in effluents

    International Nuclear Information System (INIS)

    Bidica, Nicolae; Sofalca, Nicolae; Balteanu, Ovidiu-Ioan; Stefan, Ioana-Iuliana

    2007-01-01

    In this paper we describe an improved real-time tritium monitoring system designed for Heavy Water Detritiation Pilot Plant of National Institute for Cryogenics and Isotopes Separation, Rm. Valcea, Romania. The system consists of three fixed tritium-in-air monitors which measure continuously tritium-in-air concentration (in both species: vapour and gas) in working areas and gaseous effluents. Portable tritium monitors with ionization chamber, and tritium-in-air collector combined with liquid scintillation counter method are also used to supplement fixed instrument measurements. The main functions of tritium monitoring system are: to measure tritium-in air concentration in working areas and gaseous effluents; to alarm the personnel if tritium concentration thresholds are exceeded; to integrate tritium activity released to the environment during a week and to cut off normal ventilation when the activity threshold is exceeded and start the air cleaning system. Now, several especial functions have been added, so that by using appropriate conversion factors, the tritium monitoring system is able to estimate the effective dose rate before starting an activity into the monitored area, during this activity, or soon as the activity was finished. Another new function has been added by coupling tritium-in-air monitoring system with control access system. This is very useful for quick estimation of tritium doses. For routine dosimetric survey, one the internal dose for individuals by measuring tritium in urine is estimated. With all these features our tritium monitoring system is really a safety system for personnel and for environment. (authors)

  9. Development and Application of a Structural Health Monitoring System Based on Wireless Smart Aggregates.

    Science.gov (United States)

    Yan, Shi; Ma, Haoyan; Li, Peng; Song, Gangbing; Wu, Jianxin

    2017-07-17

    Structural health monitoring (SHM) systems can improve the safety and reliability of structures, reduce maintenance costs, and extend service life. Research on concrete SHMs using piezoelectric-based smart aggregates have reached great achievements. However, the newly developed techniques have not been widely applied in practical engineering, largely due to the wiring problems associated with large-scale structural health monitoring. The cumbersome wiring requires much material and labor work, and more importantly, the associated maintenance work is also very heavy. Targeting a practical large scale concrete crack detection (CCD) application, a smart aggregates-based wireless sensor network system is proposed for the CCD application. The developed CCD system uses Zigbee 802.15.4 protocols, and is able to perform dynamic stress monitoring, structural impact capturing, and internal crack detection. The system has been experimentally validated, and the experimental results demonstrated the effectiveness of the proposed system. This work provides important support for practical CCD applications using wireless smart aggregates.

  10. Good Practice in Designing and Implementing National Monitoring Systems for Adaptation to Climate Change

    DEFF Research Database (Denmark)

    Naswa, Prakriti; Trærup, Sara Lærke Meltofte; Bouroncle, Claudia

    In this report, we identify, analyse and compare international good practices in the design and implementation of national monitoring and evaluating indicator systems for climate change adaptation. This first chapter provides an introduction to the context and key terminology in the domain...

  11. US remote monitoring operational experience

    International Nuclear Information System (INIS)

    Dupree, S.A.; Sonnier, C.S.

    1997-01-01

    Under international partnerships and bilateral agreements with the U.S. Department of Energy, Sandia National Laboratories, other national laboratories, and international partner organizations have emplaced remote monitoring systems in nuclear facilities and laboratories in various parts of the world for the purpose of conducting field trials of remote monitoring. The purpose of the present report is to review the results from these field trials and draw general conclusions regarding the trials. Many thousands of hours of sensor and system operation have been logged, and data have been retrieved from many locations. In virtually all cases the system components have functioned as intended and data have been successfully collected and transmitted for review. Comparisons between front-end-triggered video and time-lapse video have shown that the triggered record has captured all relevant monitored operations at the various nuclear facilities included in the field trials. We believe the utility and functional reliability of remote monitoring for international safeguards has been shown. However, it should be kept in mind that openness and transparency, including some form of short-notice inspections, are likely to be prerequisites to the safeguards implementation of remote monitoring in any State

  12. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  13. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  14. Application of a pedestrian portal monitor at Madrid International Airport in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, Ll., E-mail: luis.pujol@cedex.e [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Alfonso XII, 3, 28014 Madrid (Spain); Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain); Gonzalez-Gonzalez, J.A.; Suarez-Navarro, M.J. [Univ Politecn Madrid (UPM), Dept Civil Engn Hydraul and Energet, ETSI Caminos, Profesor Aranguren, s/n, 28040 Madrid (Spain)

    2011-04-15

    Three pedestrian portal monitor systems, designed to detect illicit trafficking or inadvertent movement of radioactive materials carried by passengers at airports, have been evaluated. The systems were supplied by three manufacturers: Bicron, Exploranium and Thermo-Eberline. In an initial evaluation, conducted at the Laboratory of Nuclear Engineering of the School of Civil Engineering, it was observed that the FHT-1372 system manufactured by Thermo-Eberline gave a more sensitive response and allowed the measurement of total photon dose rate and artificial photon dose rate. Therefore, this system was installed at Barajas International Airport in Madrid in 2002 for a period of 108 days in order to select an appropriate investigation level (defined as the radiation level that is selected as the trigger for further investigation). During this period 1,339,931 passengers were screened and a total of 39 alarms were triggered, 5 of which with a value 10 times the mean value of the natural background from photon radiation (which was 85 nSv/h), and no alarms exceeded 100 {mu}Sv/h at 1 m distance, which is the level of response for legal transport of radioactive materials set by the International Atomic Energy Agency (IAEA). An investigation level of approximately 1.3 times the natural background was finally selected. This value coincides with the results obtained in the ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the IAEA.

  15. Hanger-type laundry monitor system

    International Nuclear Information System (INIS)

    Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro

    1987-01-01

    Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)

  16. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  17. Cooperative monitoring of regional security agreements

    Energy Technology Data Exchange (ETDEWEB)

    Pregenzer, A.L.; Vannoni, M.; Biringer, K.L. [Sandia National Labs., Albuquerque, NM (United States). Nonproliferation and Arms Control Analysis Dept.

    1996-11-01

    This paper argues that cooperative monitoring plays a critical role in the implementation of regional security agreements and confidence building measures. A framework for developing cooperative monitoring options is proposed and several possibilities for relating bilateral and regional monitoring systems to international monitoring systems are discussed. Three bilateral or regional agreements are analyzed briefly to illustrate different possibilities. These examples illustrate that the relationship of regional or bilateral arms control or security agreements to international agreements depends on a number of factors: the overlap of provisions between regional and international agreements; the degree of interest in a regional agreement among the international community; efficiency in implementing the agreement; and numerous political considerations. Given the importance of regional security to the international community, regions should be encouraged to develop their own infrastructure for implementing regional arms control and other security agreements. A regional infrastructure need not preclude participation in an international regime. On the contrary, establishing regional institutions for arms control and nonproliferation could result in more proactive participation of regional parties in developing solutions for regional and international problems, thereby strengthening existing and future international regimes. Possible first steps for strengthening regional infrastructures are identified and potential technical requirements are discussed.

  18. SNL/VNIIEF Storage Monitoring Collaboration

    International Nuclear Information System (INIS)

    Barkanov, Boris P.; Bartberger, Jack C.; Blagin, Sergei V.; Croessmann, C. Dennis; Gruda, Jeffrey D.; Lupsha, Vitali A.; Moroskin, Dimitri V.; Nilsen, Curt A.

    1999-01-01

    Sandia National Laboratories (SNL) and the Russian Federal Nuclear Center-All Russian Research Institute for Experimental Physics (VNIIEF)(also know as Arzamas-16) are collaborating on ways to assure the highest standards on safety, security, and international accountability of fissile material. This includes systems used to reduce the need for human access to fissile material, reduce radiation exposure, and provide prompt safety-related information, and provide continuous international accountability information while reducing the need for intrusive, on-site visits. This paper will report on the ongoing SNL/VNIIEF efforts to develop technologies and monitoring systems to meet these goals. Specific topics covered will include: the Smart Bolt tag/seal development, development and testing of electronic sensor platforms (U.S. T-1 ESP and VNIIEF Radio Tag) for monitoring and transportation applications, the ''Magazine-to-Magazine'' remote monitoring system field test, and the ''Facility-to-Facility'' storage monitoring system field trial

  19. Cooperative Remote Monitoring, Arms control and nonproliferation technologies: Fourth quarter 1995

    Energy Technology Data Exchange (ETDEWEB)

    Alonzo, G M [ed.

    1995-01-01

    The DOE`s Cooperative Remote Monitoring programs integrate elements from research and development and implementation to achieve DOE`s objectives in arms control and nonproliferation. The contents of this issue are: cooperative remote monitoring--trends in arms control and nonproliferation; Modular Integrated Monitoring System (MIMS); Authenticated Tracking and Monitoring Systems (ATMS); Tracking and Nuclear Materials by Wide-Area Nuclear Detection (WAND); Cooperative Monitoring Center; the International Remote Monitoring Project; international US and IAEA remote monitoring field trials; Project Dustcloud: monitoring the test stands in Iraq; bilateral remote monitoring: Kurchatov-Argonne-West Demonstration; INSENS Sensor System Project.

  20. Plant-wide integrated equipment monitoring and analysis system

    International Nuclear Information System (INIS)

    Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.

    2004-01-01

    A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)

  1. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  2. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  3. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  4. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  5. 3rd International Conference on Condition Monitoring of Machinery in Non-Stationary Operations

    CERN Document Server

    Rubini, Riccardo; D'Elia, Gianluca; Cocconcelli, Marco; Chaari, Fakher; Zimroz, Radoslaw; Bartelmus, Walter; Haddar, Mohamed

    2014-01-01

    This book presents the processings of the third edition of the Condition Monitoring of Machinery in Non-Stationary Operations (CMMNO13) which was held in Ferrara, Italy. This yearly event merges an international community of researchers who met – in 2011 in Wroclaw (Poland) and in 2012 in Hammamet (Tunisia) – to discuss issues of diagnostics of rotating machines operating in complex motion and/or load conditions. The growing interest of the industrial world on the topics covered by the CMMNO13 involves the fields of packaging, automotive, agricultural, mining, processing and wind machines in addition to that of the systems for data acquisition.The participation of speakers and visitors from industry makes the event an opportunity for immediate assessment of the potential applications of advanced methodologies for the signal analysis. Signals acquired from machines often contain contributions from several different components as well as noise. Therefore, the major challenge of condition monitoring is to po...

  6. A metrology system for a high resolution cavity beam position monitor system

    Science.gov (United States)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Hinton, Shantell; Honda, Yosuke; Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2013-11-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved-ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  7. System of message for gamma-radiation monitor

    International Nuclear Information System (INIS)

    Bolic, M.D.; Koturovic, A.M.

    2001-01-01

    Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru

  8. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  9. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  10. Optimisation of internal contamination monitoring programme by integration of uncertainties

    International Nuclear Information System (INIS)

    Davesne, E.; Casanova, P.; Chojnacki, E.; Paquet, F.; Blanchardon, E.

    2011-01-01

    Potential internal contamination of workers is monitored by periodic bioassay measurements interpreted in terms of intake and committed effective dose by the use of biokinetic and dosimetric models. After a prospective evaluation of exposure at a workplace, a suitable monitoring programme can be defined by choosing adequate measurement techniques and frequency. In this study, the sensitivity of a programme is evaluated by the minimum intake and dose, which may be detected with a given level of confidence by taking into account uncertainties on exposure conditions and measurements. This is made for programme optimisation, which is performed by comparing the sensitivities of different alternative programmes. These methods were applied at the AREVA NC reprocessing plant and support the current monitoring programme as the best compromise between the cost of the measurements and the sensitivity of the programme. (authors)

  11. International Responsibility and the Systemic Character of International Law

    Directory of Open Access Journals (Sweden)

    Saganek Przemysław

    2017-12-01

    Full Text Available The question whether international law is a system is one of the modern topics discussed by specialists of international law. The text of P. Saganek poses this question with respect to the rules on international responsibility. The two aims are to establish whether the rules on state responsibility are a system themselves and whether they may prima facie support the idea of international law as such a system. The two prima facie answers are positive. Every violation of international law gives rise to state responsibility if it can be attributed to a state and no circumstance precluding wrongfulness is in place. In this sense the rules on state responsibility form a sub-system supporting the thesis on the systemic nature of international law. On a closer analysis one can encounter several doubts as to both answers. Paradoxically those rules are too ideal, too systemic. The author – without denying the necessity of several if not the majority of the identified rules – refers to a tendency of presenting as law some non-binding documents prepared by expert groups. This is a part of a wider process of ‘paper-law’. In this sense expert groups engage in ‘creating the language’ in which the true subjects of international law are expected to speak.

  12. International cooperative information systems

    International Nuclear Information System (INIS)

    1980-01-01

    Developing countries need mechanisms by which the information they generate themselves and development information from the rest of the world can be retrieved. The international cooperative information system is such a mechanism. Delegates to the Seminar on International Cooperative Information Systems were informed about various existing systems (INIS, AGRIS, INFOTERRA, TCDC/INRES, POPIN, DEVSIS, and INPADROC), some specialized information systems and services (CDS/ISIS and the Cassava Information Centre), and computer programs for information processing (INIS/AGRIS, CDS/ISIS, and MINISIS). The participants suggested some changes that should be made on both the national and the international levels to ensure that these systems meet the needs of developing countries more effectively. (LL)

  13. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  14. Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

    Science.gov (United States)

    Pilgrim, Jeffrey S.; Wood, William R.; Casias, Miguel E.; Vakhtin, Andrei B,; Johnson, Michael D.; Mudgett, Paul D.

    2014-01-01

    There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC

  15. Cooperative monitoring of regional security agreements

    Energy Technology Data Exchange (ETDEWEB)

    Pregenzer, A.L.; Vannoni, M.; Biringer, K.L.

    1995-08-01

    This paper argues that cooperative monitoring plays a critical role in the implementation of regional security agreements and confidence building measures. A framework for developing cooperative monitoring options is proposed and several possibilities for relating bilateral and regional monitoring systems to international monitoring systems are discussed. Three bilateral or regional agreements are analyzed briefly to illustrate different possibilities: (1) the demilitarization of the Sinai region between Israel and Egypt in the 1970s; (2) the 1991 quadripartite agreement for monitoring nuclear facilities among Brazil, Argentina, The Argentine-Brazilian Agency for Accounting and Control of Nuclear Materials and the International Atomic Energy Agency; and (3) a bilateral Open Skies agreement between Hungary and Romania in 1991. These examples illustrate that the relationship of regional or bilateral arms control or security agreements to international agreements depends on a number of factors: the overlap of provisions between regional and international agreements; the degree of interest in a regional agreement among the international community; efficiency in implementing the agreement; and numerous political considerations.Given the importance of regional security to the international community, regions should be encouraged to develop their own infrastructure for implementing regional arms control and other security agreements. A regional infrastructure need not preclude participation in an international regime. On the contrary, establishing regional institutions for arms control and nonproliferation could result in more proactive participation of regional parties in developing solutions for regional and international problems, thereby strengthening existing and future international regimes. Possible first steps for strengthening regional infrastructures are identified and potential technical requirements are discussed.

  16. Lidar system for air-pollution monitoring over urban areas

    Science.gov (United States)

    Moskalenko, Irina V.; Shcheglov, Djolinard A.; Molodtsov, Nikolai A.

    1997-05-01

    The atmospheric environmental situation over the urban area of a large city is determined by a complex combination of anthropogenic pollution and meteorological factors. The efficient way to provide three-dimensional mapping of gaseous pollutants over wide areas is utilization of lidar systems employing tunable narrowband transmitters. The paper presented describes activity of RRC 'Kurchatov Institute' in the field of lidar atmospheric monitoring. The project 'mobile remote sensing system based on tunable laser transmitter for environmental monitoring' is developed under financial support of International Scientific and Technology Center (Moscow). The objective of the project is design, construction and field testing of a DIAL-technique system. The lidar transmitter consists of an excimer laser pumping dye laser, BBO crystal frequency doubler, and scanning flat mirror. Sulfur dioxide and atomic mercury have been selected as pollutants for field tests of the lidar system under development. A recent large increase in Moscow traffic stimulated taking into consideration also the remote sensing of lower troposphere ozone because of the photochemical smog problem. The status of the project is briefly discussed. The current activity includes also collecting of environmental data relevant to lidar remote sensing. Main attention is paid to pollutant concentration levels over Moscow city and Moscow district areas.

  17. Implementation of internal monitoring programs for workers occupationally exposed by {sup 131}I in nuclear medicine services in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Dosimetria

    2017-07-01

    In nuclear medicine services (NMS), workers routinely handle radionuclides for diagnostic and therapy. This practice represents a risk of incorporation by these radionuclides. The International Atomic Energy Agency (IAEA) recommends the implementation of an internal monitoring program on workers exposed to annual effective doses greater than 1 mSv, as for example, those who handle {sup 131}I for therapy in NMS. Currently, in Brazil, there are not enough available laboratories qualified to provide internal monitoring services to attend all possible demand of internal monitoring if it such regulation were applied by the Brazilian Nuclear Regulatory Board (CNEN). The objective of this work is to disseminate simple and inexpensive methods for in vivo routine thyroid monitoring of {sup 131}I using equipment available in the NMS. Devices available in two public hospitals located in the city of Rio de Janeiro were calibrated for use in occupational internal monitoring. The equipment evaluated in this work presented enough sensitivity for such application, being suitable to access intakes of {sup 131}I in the thyroid and able to estimate doses below 1 mSv. (author)

  18. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  19. SLICEIT and TAHMO Partnerships: Students Local and International Collaboration for Climate and Environmental Monitoring, Technology Development, Education, Adaptation and Mitigation

    Science.gov (United States)

    Aishlin, P. S.; Selker, J. S.

    2015-12-01

    Climate change understanding and impacts vary by community, yet the global nature of climate change requires international collaboration to address education, monitoring, adaptation and mitigation needs. We propose that effective climate change monitoring and education can be accomplished via student-led local and international community partnerships. By empowering students as community leaders in climate-environmental monitoring and education, as well as exploration of adaptation/mitigation needs, well-informed communities and young leadership are developed to support climate change science moving forward. Piloted 2013-2015, the SLICEIT1 program partnered with TAHMO2 to connect student leaders in North America, Europe and Africa. At the international level, schools in the U.S.A and Netherlands were partnered with schools in Ghana, Kenya, and Uganda for science and cultural exchange. Each school was equipped with a climate or other environmental sensing system, real-time data publication and curricula for both formal and informal science, technology, engineering and math education and skill development. African counterparts in TAHMO's School-2-School program collect critically important data for enhanced on-the-ground monitoring of weather conditions in data-scarce regions of Africa. In Idaho, student designed, constructed and installed weather stations provide real time data for classroom and community use. Student-designed formal educational activities are disseminated to project partners, increasing hands-on technology education and peer-based learning. At the local level, schools are partnered with a local agency, research institute, nonprofit organization, industry and/or community partner that supplies a climate science expert mentor to SLICEIT program leaders and teachers. Mentor engagement is facilitated and secured by program components that directly benefit the mentor's organization and local community via climate/environment monitoring, student workforce

  20. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  1. Impact of the application of criteria of internal monitoring in radiological protection programmes in nuclear medicine services

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Juliao, L.Q.C.; Lourenco, M.C.; Melo, D.R.

    2005-01-01

    The manipulation of open sources in Nuclear Medicine services involves risks of external exposure and internal contamination. The radiological protection plan of facilities licensed by CNEN - Brazilian Nuclear Energy Commission - must include the evaluation of such risks and propose a programme of individual monitoring to control exposure and ensure the maintenance of conditions of radiation safety. The IAEA - International Atomic Energy Agency - recommendations presented in the Safety Guide RS-G-1.2 suggest that an internal worker monitoring program be implemented where there is a possibility of internal contamination lead to effective dose committed annual values equal to or greater than 1 mSv. This paper presents the application of such criteria to the radionuclides most frequently used in the field of Nuclear Medicine, taking into account the normal conditions of handling and the ranges of activity authorized by CNEN. It is concluded that iodine 131 manipulation for therapeutic purposes is the practice that presented the greatest risk of internal exposure of workers, requiring the adoption of a programme of internal monitoring of Nuclear Medicine services

  2. Suitability of monitoring methods for the optimisation of Radiological Protection in the case of internal exposure through inhalation

    International Nuclear Information System (INIS)

    Degrange, J.P.; Gibert, B.; Basire, D.

    2000-01-01

    The radiological protection system recommended by the International Commission for Radiological Protection (ICRP) for justified practices relied pn the limitation and optimisation principles. The monitoring of internal exposure is most often based on the periodic assessment of individual exposure in order to essentially insure the simple compliance with the annual dose limits. Optimisation of protection implies a realistic, sensitive and analytical assessment of individual and collective exposures in order to allow the indentification of the main sources of exposure (main sources of contamination, most exposed operators, work activities contributing the most to the exposure) and the selection of the optimal protection options. Therefore the monitoring methods must allow the realistic assessment of individual dose levels far lower than annual limits together with measurements as frequent as possible. The aim of this presentation is to discuss the ability of various monitoring methods (collective and individual air sampling, in vivo and in vitro bioassays) to fulfil those needs. This discussion is illustrated by the particular case of the internal exposure to natural uranium compounds through inhalation. Firstly, the sensitivity and the degree to which each monitoring method is realistic are quantified and discussed on the basis of the application of the new ICRP dosimetric model, and their analytical capability for the optimisation of radiological protection is then indicated. Secondly, a case study is presented which shows the capability of individual air sampling techniques to analyse the exposure of the workers and the inadequacy of static air sampling to accurately estimate the exposures when contamination varies significantly over time and space in the workstations. As far as exposure to natural uranium compounds through inhalation is concerned, the study for assessing the sensitivity, analytic ability and accuracy of the different measuring systems shows that

  3. Drinking-water monitoring systems

    International Nuclear Information System (INIS)

    1994-01-01

    A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission

  4. Ultrasound monitoring in cannulation of the internal jugular vein: anatomic and technical considerations.

    Science.gov (United States)

    Docktor, B; So, C B; Saliken, J C; Gray, R R

    1996-06-01

    To examine the effect of variations in anatomic features and operator experience on the success and complication rates of sonographically monitored cannulation of the internal jugular vein. The authors prospectively collected data for ultrasound-monitored cannulation of the internal jugular vein in 150 patients. In all cases the radiologist recorded the side of puncture, the number of passes needed, the number of vein punctures (one or two), whether the walls were opposed during puncture and any complications. For the last 80 patients the following information was also recorded: the distance from the skin to the internal jugular vein, the diameter of the vein with the Valsalva manoeuvre and the location of the vein relative to the carotid artery. All but three of the cannulations were performed by one of three radiologists, all of whom had at least 5 years of experience. Cannulation was successful in all of the patients, and the first pass was successful in 133 (88.7%). These results are better than those of blind placement techniques reported in the literature. The only complications were hematoma and carotid puncture, which both occurred in the same two patients (1.3%). There was no significant difference among the radiologists in the number of passes needed (one-way analysis of variance, p > 0.05). The number of passes was independent of anatomic factors, including depth from skin, vein diameter or relative location. However, significantly more passes were needed for left-side punctures than for right-side punctures (Student t-test, p < 0.05). Real-time ultrasound monitoring is superior to blind techniques in cannulation of the internal jugular vein because of its ease, accuracy and safety. Sonographic real-time monitoring minimizes the impact of anatomic factors on success and complication rates. It is a safe and efficacious approach that should be preferred in the placement of central lines.

  5. The European Union Building Peace Near and Afar: Monitoring the Implementation of International Peace Agreements

    Directory of Open Access Journals (Sweden)

    Máire Braniff

    2013-11-01

    Full Text Available The European Union’s (EU support and contribution to international peace and security continues to develop with involvement in the Balkans, South Caucasus, Africa, Middle East and South Asia (Council of the European Union 2005. Within the broad range of civilian and military interventions under the Common Security and Defence policy (CSDP there have been two monitoring missions that have emerged from peace agreements, in Aceh (2005-2006 and in Georgia (2008 to date. This article maps the evolution EU’s role in international peace building by focusing on how this role is increasingly constructed by the scope of monitoring missions which it has embarked upon outside of its borders. A thematic analysis of literature is used to explore how the EU’s monitoring role has evolved regarding the different degrees of intervention, time-frame and size of the monitoring mission which have resulted in a multi-level impact regarding societal transition. The article finds that political will, shadows of past and future missions and intergovernmental concerns dominates how the EU’s monitoring missions unfurl, affecting the practice of monitors and other EU actors in local conflict settings and contemplates scenarios for future monitoring missions.

  6. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  7. A framework for the monitoring and evaluation of international surgical initiatives in low- and middle-income countries.

    Science.gov (United States)

    Ibrahim, George M; Cadotte, David W; Bernstein, Mark

    2015-01-01

    An estimated two billion people worldwide lack adequate access to surgical care. To address this humanitarian emergency, an increasing number of international surgical partnerships are emerging between developed and low- and middle-income countries (LMICs). At present, there are no clear indicators that may be used to assess the effectiveness of such initiatives. We conducted an international qualitative study of 31 surgeons from developed and LMICs involved in international partnerships across a variety of subspecialties. Thematic analysis and grounded theory were applied in order to develop a practical framework that may be applied to monitor and evaluate global surgical initiatives. Several themes emerged from the study: (i) there is a large unmet need to establish and maintain prospective databases in LMICs to inform the monitoring and evaluation of international surgical partnerships; (ii) assessment of initiatives must occur longitudinally over the span of several years; (ii) the domains of assessment are contextual and encompass cultural, institutional and regional factors; and (iv) evaluation strategies should explore broader impact within the community and country. Based on thematic analysis within the domains of inputs, outputs and outcomes, a framework for the monitoring and evaluation of international surgical initiatives, the Framework for the Assessment of InteRNational Surgical Success (FAIRNeSS) is proposed. In response to the increasing number of surgical partnerships between developed and LMICs, we propose a framework to monitor and evaluate international surgical initiatives.

  8. Development of a Versatile Ultrasonic Internal Pipe/Vessel Component Monitor for In-Service Inspection of Nuclear Reactor Components

    Energy Technology Data Exchange (ETDEWEB)

    Searfass, Clifford T. [Structural Integrity Associates, Inc., State College, PA (United States); Malinowski, Owen M. [Structural Integrity Associates, Inc., State College, PA (United States); Van Velsor, Jason K. [Structural Integrity Associates, Inc., State College, PA (United States)

    2015-03-22

    The stated goal of this work was to develop a versatile system which could accurately measure vessel and valve internal vibrations and cavitation formation under in-service conditions in nuclear power plants, ultrasonically. The developed technology will benefit the nuclear power generation industry by allowing plant operators to monitor valve and vessel internals during operation. This will help reduce planned outages and plant component failures. During the course of this work, Structural Integrity Associates, Inc. gathered information from industry experts that target vibration amplitudes to be detected should be in the range of 0.001-in to 0.005-in (0.025-mm to 0.127-mm) and target vibration frequency ranges which should be detected were found to be between 0-Hz and 300-Hz. During the performed work, an ultrasonic measuring system was developed which utilized ultrasonic pulse-echo time-of-flight measurements to measure vibration frequency and amplitude. The developed system has been shown to be able to measure vibration amplitudes as low as 0.0008-in (0.020-mm) with vibration frequencies in the range of 17-Hz to 1000-Hz. Therefore, the developed system was able to meet the industry needs for vibration measurement. The developed ultrasonic system was also to be able to measure cavitation formation by monitoring the received ultrasonic time- and frequency-domain signals. This work also demonstrated the survivability of commercially available probes at temperatures up to 300-F for several weeks.

  9. Monitoring poverty in the Philippines | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-07-15

    Jul 15, 2011 ... Measuring quality-of-life ... Through this work, a community-based poverty monitoring system has ... Regular surveys provide data on macro variables, such as the rate of inflation, the exchange rate, and the balance of trade.

  10. Rapid monitoring of large groups of internally contaminated people following a radiation accident

    International Nuclear Information System (INIS)

    1994-05-01

    In the management of an emergency, it is necessary to assess the radiation exposures of people in the affected areas. An essential component in the programme is the monitoring of internal contamination. Existing fixed installations for the assessment of incorporated radionuclides may be of limited value in these circumstances because they may be inconveniently sited, oversensitive for the purpose, or inadequately equipped and staffed to cope with the large numbers referred to them. The IAEA considered it important to produce guidance on rapid monitoring of large groups of internally contaminated people. The purpose of this document is to provide Member States with an overview on techniques that can be applied during abnormal or accidental situations. Refs and figs

  11. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  12. Critical function monitoring system algorithm development

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1984-01-01

    Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms

  13. Development and characterization of two-component albedo based neutron individual monitoring system using thermoluminescent detectors

    International Nuclear Information System (INIS)

    Martins, Marcelo Marques

    2008-01-01

    A TLD-albedo based two-component neutron individual monitoring system was developed and characterized in this work. The monitor consists of a black plastic holder, an incident neutron boron loaded shield, a moderator polyethylene body (to increase its response), two pairs of TLD-600 and TLD-700 (one pair to each component) and an adjustable belt. This monitoring system was calibrated in thermal neutron fields and in 70 keV, 144 keV, 565 keV, 1.2 MeV and 5 MeV monoenergetic neutron fields. In addition, it was calibrated in 252C f(D 2 O), 252 Cf, 241 Am-B, 241 Am-Be and 238 Pu-Be source fields. For the latter, the lower detection levels are, respectively, 0.009 mSv, 0.06 mSv, 0.12 mSv, 0.09 mSv and 0.08 mSv. The participation in an international intercomparison sponsored by IAEA with simulated workplace fields validated the system. The monitoring system was successfully characterized in the ISO 21909 standard and in an IRD - the Brazilian Institute for Radioprotection and Dosimetry - technical regulation draft. Nowadays, the neutron individual system is in use by IRD for whole body individual monitoring of five institutions, which comprehend several activities. (author)

  14. A critical friend: monitoring and evaluation systems, development cooperation and local government. The case of Tuscany.

    Science.gov (United States)

    Rossignoli, Serena; Coticchia, Fabrizio; Mezzasalma, Annarosa

    2015-06-01

    The role of monitoring and evaluation (M&E) systems in the field of development cooperation has globally increased in last decades. International and regional organizations, as well as states, local governments and NGOs have largely adopted the tools provided by M&E in order to enhance transparency, effectiveness and efficiency. The paper aims at verifying how and to what extent the implementation of M&E systems has affected the overall quality of international cooperation projects financed by a local government. After a literature review on M&E in development cooperation, the research analyzes the wide range of activities (evaluation ex-ante, mid-term, final, monitoring, consultancy) carried out by the Evaluation Team of the XY in the last eight years in behalf of an Italian local government: the Region of Tuscany. The paper reveals the strategic significance of adopting M&E systems in the medium-long term. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. A metrology system for a high resolution cavity beam position monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Walston, Sean, E-mail: walston2@llnl.gov [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Boogert, Stewart [Royal Holloway, University of London, Egham (United Kingdom); Chung, Carl; Fitsos, Pete [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Frisch, Joe [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Gronberg, Jeff [Lawrence Livermore National Laboratory, 7000 East Ave., L-181, Livermore, CA 94550 (United States); Hayano, Hitoshi [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Hinton, Shantell [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Honda, Yosuke [High Energy Accelerator Research Organization (KEK), Tsukuba-shi, Ibaraki-ken (Japan); Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Lyapin, Alexey; Malton, Stephen [University College London, London (United Kingdom); May, Justin; McCormick, Douglas [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Meller, Robert [Cornell University, Ithaca, NY (United States); Miller, David [University College London, London (United Kingdom); Orimoto, Toyoko [University of California and Lawrence Berkeley National Laboratory, Berkeley, CA (United States); California Institute of Technology, Pasadena, CA (United States); Ross, Marc [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Fermi National Accelerator Laboratory, Batavia, IL (United States); and others

    2013-11-11

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved–ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  16. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  17. Distributed intelligent urban environment monitoring system

    Science.gov (United States)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  18. Internal exposure monitoring of personnel of a nuclear power plant with pressurized-water reactors

    International Nuclear Information System (INIS)

    Krueger, F.W.; Poulheim, K.F.; Rueger, G.; Schreiter, W.D.

    1982-01-01

    In the GDR a programme for monitoring the internal radiation exposure of personnel has been established in the Bruno Leuschner Nuclear Power Plant, Greifswald, which allows one to estimate the effective dose equivalent in the way recommended by the ICRP. The measuring equipment used, and the methods of calibration and of evaluation of results are described. At present about 400 persons are monthly monitored with a thorax monitor in the nuclear power plant. If an investigation level - corresponding to an effective dose equivalent of 0.3mSv/month - is exceeded, a more exact measurement is made in the whole-body counter at the National Board for Nuclear Safety and Radiation Protection of the GDR. In addition, a selected group of 50 persons is measured twice yearly in the whole-body counter. The measurements show the high effectiveness of the protective measures against radionuclide intake by workers in the nuclear power plant, resulting in a contribution of less than 1% to the collective dose of the personnel. A correlation has been found between external and internal exposure indicating that, in general, there will be a higher intake only under conditions resulting also in higher external exposures. The highest individual values of internal exposure found are below 0.5mSv/month and thus within the range of the lower detection limit of dosimeter films used for monitoring the external exposure. (author)

  19. Standardization of radioactive gaseous waste radiation monitoring equipment from the International Electrotechnical Commission

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1983-01-01

    After having introduced the works performed by the International Electrotechnical Commission, the authors report on the results of the studies carried out to achieve the standardization of the radiation monitoring equipment concerning the control of the gaseous waste from nuclear installations. The authors present the most interesting aspects of the regulations and recommendations, which include not only a description of the minimum permissible levels of sensitivity for the monitors, but also a description of the set of assays to be established in order to verify the level of performance of the monitors

  20. Vibration monitoring of the mechanical behavior of the internal structures of PWR reactors

    International Nuclear Information System (INIS)

    Assedo, R.; Carre, J.C.; Sol, J.C.

    1979-01-01

    The internal structures of pressurized water reactors are the seat of vibrations induced by fluctuations in primary fluid flow. A knowledge of these phenomena is indispensable in order to ensure that the structures are in proper mechanical order. It can also be used for operational monitoring. This paper describes all the methods developed and the results already achieved in this domain. The first part deals with tests on mockup associated with the calculation models which afforded a good knowledge of the vibrational characteristics of the internal structures, as well as the measurements made during hot tests of certain reactors which made it possible to qualify these models on real structures. The second part describes the means of detection (neutron noise, external accelerometers) as well as the processing methods used in the follow-up. A few typical results obtained on site are then presented. Finally, the general principles of operational monitoring of the mechanical behavior of the internal structures are described [fr

  1. The Assessment of I-131 Internal Doses of Nuclear Medicine Workers in Korea Using Thyroid uptake system

    International Nuclear Information System (INIS)

    Bahn, Young Kag; Oh, Gi Back; Lee, Chang Ho; Lee, Jong Doo; Yeom, Yu Sun; Hwang, Young Muk

    2012-01-01

    There are possibilities the radiation workers could intake the radiation when workers deal with radiation-materials. Therefore, internal radiation doses of radiation workers need to be assessed. Although an application of the nuclear medicine is continuously increased in Korea, there is not a proper tool and form to monitor the internal doses of nuclear medicine workers. However, it is possible to attain the internal doses of I-131 to evaluate using thyroid uptake and well count system. In this study, we measured and evaluated the I-131 internal doses of nuclear medicine workers in Korea using thyroid uptake and well count system and performed an air sampling

  2. Real Time Environmental Radiation Monitoring System in the Philippines

    International Nuclear Information System (INIS)

    Garcia, Teofilo Y.

    2015-01-01

    The widespread release of radioactive materials caused by the Fukushima Daiichi Nuclear Power Plant Accident that occurred on 11 March 2011 raised concerns on the environmental radiation monitoring Presently, the Philippine Nuclear Research Institute (PNRI) can only perform limited incident. Country-wide radiation measurements by carrying out field-works in the different provinces of the country. This is due to limitation in the availability of appropriate equipment to carry-out the task of conducting radiation measurements, especially in remote and hart to access areas of the country. Although no nuclear reactor is currently operating in the Philippines, it is situated in a region surrounded by neighboring countries with several existing or planned nuclear power plants. While nuclear power has tremendous benefits in meeting the electricity needs of growing populations, and does not have the adverse environmental effects associated with burning of fossil fuels, there are potential risks from releases of radio nuclides into the environment. The PNRI, through the support of the International Atomic Energy Agency (IAEA), is establishing an on-line environmental radiation monitoring system that can provide real-time environmental during emergencies that lead to extensive spread of radioactive materials, such as nuclear power plant accidents, an on-line radiation monitoring system will enable the immediate detection of radiological emergencies affecting the country and will provide important information of authorities for appropriate emergency response. (author)

  3. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  4. Online NPP monitoring with neuro-expert system

    International Nuclear Information System (INIS)

    Nabeshima, K.

    2002-01-01

    This study present a hybrid monitoring system for nuclear power plant utilizing neural networks and a rule-based expert system. The whole monitoring system including a data acquisition system and the advisory displays has been tested by an on-line simulator of pressurized water reactor. From the testing results, it was shown that the neural network in the monitoring system successfully modeled the plant dynamics and detected the symptoms of anomalies earlier than the conventional alarm system. The expert system also worked satisfactorily in diagnosing and displaying the system status by using the outputs of neural networks and a priori knowledge base

  5. Relationship between the international marketing research and the international marketing information system

    Directory of Open Access Journals (Sweden)

    Grubor Aleksandar

    2004-01-01

    Full Text Available Real and complete understanding relationship between the international marketing research and the international marketing information system requires recognizing essentials of the both concept. The international marketing research constitutes a process with coherent phases, whereas the international marketing information system is a part of integrated company's information system. Approach to learning relationship between the international marketing research and the international marketing information system is distinguish in domestic than in the foreign expert literature.

  6. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  7. Emergency preparedness and internal contamination monitoring

    International Nuclear Information System (INIS)

    Rahola, T.; Suomela, M.

    2000-01-01

    After the radiation accidents in Chernobyl, Ukraina in 1986 and in Goiania, Brasil in 1987, much resource have been spent on improving emergency preparedness. Especially regarding transfer of information using the most recent techniques and establishment of 24 hour emergency service of radiation safety experts the development has been fast. The very first measures in a possible emergency situation have been trained nationally and internationally. Less attention has been paid to measures in a somewhat later phase. To be able to react fast enough in an emergency situation it is essential to have well documented plans, written instructions and suitable measurement equipment ready for use. Equally important is that there is trained staff prepared to do measurements without delay. In the first phase of a nuclear accident radioactive iodine is of primary concern regarding internal contamination. After the Chernobyl accident the number of childhood thyroidea cancer clearly exceeded the expected number. Reliable direct measurements of I-131 in the thyroidea in Ukraina, Russia and Belarussia were done only to a limited number of children. Many uncertainties are involved in the data used for dose estimation. Later the body burdens of radiocesium or other radionuclides might be of most importance. Normal whole-body counting instruments can be used if only small groups need to be measured. For large groups of people in an emergency situation faster methods are needed. Different types of monitors installed at places where radiation workers are controlled for internal contamination as well as gamma cameras at hospitals can be used. Rapid field measurements of the whole-body and especially of the thyroid can been done with less sophisticated instruments. In the acute phase of a nuclear accident such measurements should be done without delay. Instruments and staff trained to use them should be available and plans for which groups of people to measure prepared. The detection level

  8. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  9. Vibro-acoustic condition monitoring of Internal Combustion Engines: A critical review of existing techniques

    Science.gov (United States)

    Delvecchio, S.; Bonfiglio, P.; Pompoli, F.

    2018-01-01

    This paper deals with the state-of-the-art strategies and techniques based on vibro-acoustic signals that can monitor and diagnose malfunctions in Internal Combustion Engines (ICEs) under both test bench and vehicle operating conditions. Over recent years, several authors have summarized what is known in critical reviews mainly focused on reciprocating machines in general or on specific signal processing techniques: no attempts to deal with IC engine condition monitoring have been made. This paper first gives a brief summary of the generation of sound and vibration in ICEs in order to place further discussion on fault vibro-acoustic diagnosis in context. An overview of the monitoring and diagnostic techniques described in literature using both vibration and acoustic signals is also provided. Different faulty conditions are described which affect combustion, mechanics and the aerodynamics of ICEs. The importance of measuring acoustic signals, as opposed to vibration signals, is due since the former seem to be more suitable for implementation on on-board monitoring systems in view of their non-intrusive behaviour, capability in simultaneously capturing signatures from several mechanical components and because of the possibility of detecting faults affecting airborne transmission paths. In view of the recent needs of the industry to (-) optimize component structural durability adopting long-life cycles, (-) verify the engine final status at the end of the assembly line and (-) reduce the maintenance costs monitoring the ICE life during vehicle operations, monitoring and diagnosing system requests are continuously growing up. The present review can be considered a useful guideline for test engineers in understanding which types of fault can be diagnosed by using vibro-acoustic signals in sufficient time in both test bench and operating conditions and which transducer and signal processing technique (of which the essential background theory is here reported) could be

  10. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  11. Relationship between the international marketing research and the international marketing information system

    OpenAIRE

    Grubor Aleksandar

    2004-01-01

    Real and complete understanding relationship between the international marketing research and the international marketing information system requires recognizing essentials of the both concept. The international marketing research constitutes a process with coherent phases, whereas the international marketing information system is a part of integrated company's information system. Approach to learning relationship between the international marketing research and the international marketing in...

  12. Online: a program to display histograms and control monitor processes on the WA62 VAX data acquisition system at CERN

    International Nuclear Information System (INIS)

    Hand, R.P.

    1981-02-01

    ONLINE is a program which can be launched from any terminal on the WA62 experiment's DEC VAX 11/780 computer when the Native mode data acquisition system is running. It is used to display histograms produced by the various experiment monitor processes running under the system and can establish links with such processes to allow the user to issue monitor commands and change internal monitor process parameters. This report describes the criteria used in the design of ONLINE and shows some of the features of the VAX/VMS Operating System which are used to access histograms produced by monitor processes, to establish communications links with monitor processes and to provide the user with an easy to learn system for the examination of online experimental data in a graphical form. Also given, is a brief account of the way monitor processes are structured and how this structure facilitates user-monitor dialogue. (author)

  13. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  14. Life Support Systems: Environmental Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...

  15. Acoustic emission leak monitoring system LMS-96

    International Nuclear Information System (INIS)

    Liska, J.; Cvrcek, M.; Mueller, L.

    1997-01-01

    On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)

  16. Monitoring and radiation dose estimation for internal contamination of occupational workers

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    The assessment of interval radiation doses due to intake of radionuclides differs totally from external dosimetry. External dosimetry is relatively straight forward: Workers are equipped with appropriate dosimeters that give the dose upon direct reading. Internal dosimetry is actually an assessment of the dose based on results of personnel and environmental monitoring (authors).

  17. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  18. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  19. Sensitivity of a low energy Ge detector system for in vivo monitoring in the framework of ICRP 78 applications.

    Science.gov (United States)

    Lopez, M A; Navarro, T

    2003-01-01

    In in vivo detection of internal contamination by actinides the minimum detectable activities (MDAs) correspond to significant doses, so the sensitivity of the detection system is the key to establishing adequate individual monitoring programmes for internal exposure to these radionuclides. The whole body counting (WBC) faculty at CIEMAT uses a low-energy Ge detector system with different available counting geometries to estimate the retention of actinides in the lungs and evaluate 125I in thyroid and 241Am in bone (skull and knee). A study of the factors and uncertainties involved in estimations of MDA is presented for lung and thyroid monitoring. The dependence of detection limits on counting efficiency in the measurement of low-energy emitters in the lungs has been carefully studied, carrying out a comparison among different biometric equations obtained by ultrasound techniques for estimations of chest wall thickness. Dosimetric implications of the estimated MDAs are taken into account in the framework of ICRP 78 application and considering Spanish regulations. The main interest in lung measurements is for the assessment of occupational exposure. This work confirms the low-energy Ge detector system to be an adequate in vivo technique for the routine monitoring of internal exposure to most insoluble uranium compounds (detection of 3% enriched uranium in lungs), and also to be useful in special monitoring programmes or in the case of incidents when the detection of 241Am is required.

  20. A global change data base using thematic mapper data: Earth monitoring educational system (EMES)

    International Nuclear Information System (INIS)

    D'Antoni, H.L.; Peterson, D.L.

    1992-01-01

    The creation of an Earth Monitoring Educational System integrated with the research interests of NASA Ames Research Center and one or more university schools is proposed. This would be a first step in a new educational system at an international scale. Based on the integration of a global network of cooperators to build a global data base for assessments of global change, the EMES will promote AS, BS, MS and PhDs in global ecology at associated universities and colleges, and extra-curricular courses for multilevel audiences. These would range as appropriate from ministers to resource managers to students. Both programs will be conducted under a systemic approach, through active learning, coordination and correlation practices. They will be aimed to: (1) train specialists, (2) establish a tradition of solving regional problems concerning global change in a systemic manner, using remote sensing technology as the monitoring tool, and (3) transfer knowledge on global change to the national and world communities. The main goal of the extra-curricular courses would be to provide readily usable knowledge to the decision-making levels of all the participant countries and institutions. South America is proposed as the pilot continent for the project. This work is consistent with the educational goals of the International Space year in 1992

  1. Radiological emergency monitoring systems in the Nordic and Baltic Sea countries

    International Nuclear Information System (INIS)

    Devell, L.; Lauritzen, B.

    2001-02-01

    This report describes the national systems for emergency monitoring of radioactivity in the five Nordic countries, Denmark, Finland, Iceland, Norway and Sweden as well as in the six Baltic Sea countries, Estonia, Germany, Latvia, Lithuania, Poland and the Russian Federation. Similarities and differences regarding strategy and equipment are shown briefly. The main feature for early warning is the national network of automatic gamma monitoring stations. This network is supplemented by manual stations and/or survey teams, often measuring at predetermined locations. Air filter stations are used for nuclide analyses of particles and gases. Dose rate maps and fallout maps of ground deposited nuclides, e.g., cesium-137, are produced based on data from airborne measurements, monitoring stations, survey teams and environmental samples. Most countries describe programs for checking food contamination. Whole body counting and organ measurements are used to determine internal contamination. External contamination of people, vehicles, goods etc is checked with survey meters and other equipment at checkpoint or as needed. Field measurements of various kinds complete the national systems. Possible future development and planned improvement are discussed. This report is an extension and update of a previous NKS report covering the Nordic countries. (au)

  2. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  3. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  4. Standard-D hydrogen monitoring system, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1996-01-01

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS

  5. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  6. Rockwell International - Rocky Flats Plant: Occupational Health Information System

    International Nuclear Information System (INIS)

    Bistine, R.W.; Petrocchi, A.; Wright, W.L.; Yoder, R.E.; Fischer, C.M.

    1984-01-01

    The Rockwell International-Rocky Flats Occupational Health Information System uses the FLOW GEMINI software on a VAX computer system. The system is extremely user friendly, flexible, comprehensive, and easily customized by the user. The system contains the editioned files (i.e., time organized historical data) of the Medical, Industrial Hygiene, Health Physics, and Safety Departments. It maintains, analyzes and reports on data from employee medical and work histories, medical exams, workplace monitoring, and health effects related to specific hazards or locations in the workplace. It identifies and reports potential individual and group problems through regular reports and responses to on-line queries. In addition, it schedules examination, sampling, produces standard user-defined reports, and provides statistical analysis capabilities. The system presently contains a file of more than 20,000 Material Data Safety Sheets. A user group provides a mechanism for sharing ideas and continual software enhancement. 11 figures

  7. FFTF fission gas monitor computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports

  8. Monitoring and evaluation of human resources for health: an international perspective

    Directory of Open Access Journals (Sweden)

    Gupta Neeru

    2003-04-01

    Full Text Available Abstract Background Despite the undoubted importance of human resources to the functions of health systems, there is little consistency between countries in how human resource strategies are monitored and evaluated. This paper presents an integrated approach for developing an evidence base on human resources for health (HRH to support decision-making, drawing on a framework for health systems performance assessment. Methods Conceptual and methodological issues for selecting indicators for HRH monitoring and evaluation are discussed, and a range of primary and secondary data sources that might be used to generate indicators are reviewed. Descriptive analyses are conducted drawing primarily on one type of source, namely routinely reported data on the numbers of health personnel and medical schools as covered by national reporting systems and compiled by the World Health Organization. Regression techniques are used to triangulate a given HRH indicator calculated from different data sources across multiple countries. Results Major variations in the supply of health personnel and training opportunities are found to occur by region. However, certain discrepancies are also observed in measuring the same indicator from different sources, possibly related to the occupational classification or to the sources' representation. Conclusion Evidence-based information is needed to better understand trends in HRH. Although a range of sources exist that can potentially be used for HRH assessment, the information that can be derived from many of these individual sources precludes refined analysis. A variety of data sources and analytical approaches, each with its own strengths and limitations, is required to reflect the complexity of HRH issues. In order to enhance cross-national comparability, data collection efforts should be processed through the use of internationally standardized classifications (in particular, for occupation, industry and education at the

  9. Silicon PIN diode based electron-gamma coincidence detector system for Noble Gases monitoring.

    Science.gov (United States)

    Khrustalev, K; Popov, V Yu; Popov, Yu S

    2017-08-01

    We present a new second generation SiPIN based electron-photon coincidence detector system developed by Lares Ltd. for use in the Noble Gas measurement systems of the International Monitoring System and the On-site Inspection verification regimes of the Comprehensive Nuclear-Test Ban Treaty (CTBT). The SiPIN provide superior energy resolution for electrons. Our work describes the improvements made in the second generation detector cells and the potential use of such detector systems for other applications such as In-Situ Kr-85 measurements for non-proliferation purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Optimization of internal contamination monitoring programmes by studying uncertainties linked to dosimetric assessment

    International Nuclear Information System (INIS)

    Davesne, Estelle

    2010-01-01

    To optimise the protection of workers against ionizing radiations, the International Commission on Radiological Protection recommends the use of dose constraint and limits. To verify the compliance of the means of protection with these values when a risk of internal contamination exists, monitoring programmes formed of periodic bioassay measurements are performed. However, uncertainty in the dose evaluation arises from the variability of the activity measurement and from the incomplete knowledge of the exposure conditions. This uncertainty was taken into account by means of classical, Bayesian and possibilist statistics. The developed methodology was applied to the evaluation of the potential exposure during nuclear fuel preparation or mining; and to the analysis of the monitoring programme of workers purifying plutonium in AREVA NC La Hague reprocessing plant. From the measurement decision threshold, the minimum dose detectable (MDD) by the programme with a given confidence level can be calculated through the software OPSCI. It is shown to be a useful support in the optimisation of monitoring programmes when seeking a compromise between their sensitivity and their costs. (author)

  11. Moisture monitoring and control system engineering study

    International Nuclear Information System (INIS)

    Carpenter, K.E.; Fadeff, J.G.

    1995-01-01

    During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria

  12. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  13. Ulysses spacecraft control and monitoring system

    Science.gov (United States)

    Hamer, P. A.; Snowden, P. J.

    1991-01-01

    The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

  14. Development of database management system for monitoring of radiation workers for actinides

    International Nuclear Information System (INIS)

    Kalyane, G.N.; Mishra, L.; Nadar, M.Y.; Singh, I.S.; Rao, D.D.

    2012-01-01

    Annually around 500 radiation workers are monitored for estimation of lung activities and internal dose due to Pu/Am and U from various divisions of Bhabha Atomic Research Centre (Trombay) and from PREFRE and A3F facilities (Tarapur) in lung counting laboratory located at Bhabha Atomic Research Centre hospital under Routine and Special monitoring program. A 20 cm diameter phoswich and an array of HPGe detector were used for this purpose. In case of positive contamination, workers are followed up and monitored using both the detection systems in different geometries. Management of this huge data becomes difficult and therefore an easily retrievable database system containing all the relevant data of the monitored radiation workers. Materials and methods: The database management system comprises of three main modules integrated together: 1) Apache server installed on a Windows (XP) platform (Apache version 2.2.17) 2) MySQL database management system (MySQL version 5.5.8) 3) PHP (Preformatted Hypertext) programming language (PHP version 5.3.5). All the 3 modules work together seamlessly as a single software program. The front end user interaction is through an user friendly and interactive local web page where internet connection is not required. This front page has hyperlinks to many other pages, which have different utilities for the user. The user has to log in using username and password. Results and Conclusions: Database management system is used for entering, updating and management of lung monitoring data of radiation workers, The program is having following utilities: bio-data entry of new subjects, editing of bio-data of old subjects (only one subject at a time), entry of counting data of that day's lung monitoring, retrieval of old records based on a number of parameters and filters like date of counting, employee number, division, counts fulfilling a given criterion, etc. and calculation of MEQ CWT (Muscle Equivalent Chest Wall Thickness), energy

  15. International health research monitoring: exploring a scientific and a cooperative approach using participatory action research.

    Science.gov (United States)

    Chantler, Tracey; Cheah, Phaik Yeong; Miiro, George; Hantrakum, Viriya; Nanvubya, Annet; Ayuo, Elizabeth; Kivaya, Esther; Kidola, Jeremiah; Kaleebu, Pontiano; Parker, Michael; Njuguna, Patricia; Ashley, Elizabeth; Guerin, Philippe J; Lang, Trudie

    2014-02-17

    To evaluate and determine the value of monitoring models developed by the Mahidol Oxford Tropical Research Unit and the East African Consortium for Clinical Research, consider how this can be measured and explore monitors' and investigators' experiences of and views about the nature, purpose and practice of monitoring. A case study approach was used within the context of participatory action research because one of the aims was to guide and improve practice. 34 interviews, five focus groups and observations of monitoring practice were conducted. Fieldwork occurred in the places where the monitoring models are coordinated and applied in Thailand, Cambodia, Uganda and Kenya. Participants included those coordinating the monitoring schemes, monitors, senior investigators and research staff. Transcribed textual data from field notes, interviews and focus groups was imported into a qualitative data software program (NVIVO V. 10) and analysed inductively and thematically by a qualitative researcher. The initial coding framework was reviewed internally and two main categories emerged from the subsequent interrogation of the data. The categories that were identified related to the conceptual framing and nature of monitoring, and the practice of monitoring, including relational factors. Particular emphasis was given to the value of a scientific and cooperative style of monitoring as a means of enhancing data quality, trust and transparency. In terms of practice the primary purpose of monitoring was defined as improving the conduct of health research and increasing the capacity of researchers and trial sites. The models studied utilise internal and network wide expertise to improve the ethics and quality of clinical research. They demonstrate how monitoring can be a scientific and constructive exercise rather than a threatening process. The value of cooperative relations needs to be given more emphasis in monitoring activities, which seek to ensure that research protects

  16. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  17. FRIEND: a brain-monitoring agent for adaptive and assistive systems.

    Science.gov (United States)

    Morris, Alexis; Ulieru, Mihaela

    2012-01-01

    This paper presents an architectural design for adaptive-systems agents (FRIEND) that use brain state information to make more effective decisions on behalf of a user; measuring brain context versus situational demands. These systems could be useful for alerting users to cognitive workload levels or fatigue, and could attempt to compensate for higher cognitive activity by filtering noise information. In some cases such systems could also share control of devices, such as pulling over in an automated vehicle. These aim to assist people in everyday systems to perform tasks better and be more aware of internal states. Achieving a functioning system of this sort is a challenge, involving a unification of brain- computer-interfaces, human-computer-interaction, soft-computin deliberative multi-agent systems disciplines. Until recently, these were not able to be combined into a usable platform due largely to technological limitations (e.g., size, cost, and processing speed), insufficient research on extracting behavioral states from EEG signals, and lack of low-cost wireless sensing headsets. We aim to surpass these limitations and develop control architectures for making sense of brain state in applications by realizing an agent architecture for adaptive (human-aware) technology. In this paper we present an early, high-level design towards implementing a multi-purpose brain-monitoring agent system to improve user quality of life through the assistive applications of psycho-physiological monitoring, noise-filtering, and shared system control.

  18. Hydroacoustics and infrasound: Possibilities for international cooperation

    International Nuclear Information System (INIS)

    North, R.G.

    1999-01-01

    The data provided by the International Monitoring system and the Products generated by the International data Center will be a unique source not only for CTBT verification but also for other activities. Although the utility of hydro acoustic and infrasonic data for such purposes is less obvious than that of seismic and radionuclide data, there are several possible applications for hazard and disaster warning purposes, and many potential long-term benefits for research and development. Such wider benefits from the monitoring system will best be realized through open international cooperation

  19. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    At Tokai Research Establishment, JAERI, over one thousand people work in hot areas such as reactors, accelerators, chemical laboratories and waste treatment plants. The monitoring for internal contamination of this personnel is presented. Routine and special monitoring are carried out. The object of the former is to check for the presence of significant contamination, and that of the latter is to estimate body burden and committed dose equivalent, if necessary. Heavy shield and shadow shield whole body counters, a low energy lung counter and a wound monitor are used to detect the internal contamination due to γ or chi ray emitters, and bioassay technique is used for α or β emitters and uranium. The results of the monitoring until now are presented. (H.K.)

  20. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  1. Study on Developing a System with IP Functionality to Monitor the Status of Containers in Maritime Logistics

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2017-12-01

    Full Text Available There has been increasing demand from consignors and shipping companies for real-time monitoring of maritime cargo due to increases in fresh, dangerous, and high-value cargo. Although larger carriers have developed and integrated their own systems for such real-time monitoring services, small- and medium-sized shippers are struggling with the heavy costs and workforce associated with such capability. This study introduces a system that can do real-time monitoring of the location of shipping containers and their internal status by using IP-RFID that in cludes IP functionality. This system is composed of a tag, a smart point, and a service platform.  The monitoring tags are attached to regular containers to track the opening and closing of the doors, the internal temperature, and humidity. The tags then send the data to the smart point where the GPS information is added. The data packet is then finally transmitted to the service platform for location tracking.  In particular, as the tags in this system have IP functionality like Multicast, they are capable of communicating with the users and also allow users to control them. In order to provide such functionality, the smart points can serve as a gateway between the service platform and the tag. By managing the tag’s connection information and the status of transmission at the smart point, the service platform can directly communicate with tags connected to the respective smart point. This technology could be applied in a diverse range of maritime and non-maritime areas including warehouse management. As for maritime logistics, it also often goes through ground, port, and air transportation phases. Further studies should monitor the actual performance of this equipment across the various phases of maritime logistics to empirically test the systems proposed herein.

  2. Design, development, and field demonstration of a remotely deployable water quality monitoring system

    Science.gov (United States)

    Wallace, J. W.; Lovelady, R. W.; Ferguson, R. L.

    1981-01-01

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

  3. Guidance on internal dose assessments from monitoring data (Project IDEAS)

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Bailey, M.; Berkovski, V.; Castellani, M.; Hurtgen, C.; Jourdain, R.; Le Guen, B.

    2003-01-01

    Several international intercomparison exercises on intake and internal dose assessments from monitoring data led to the conclusion that the results calculated by different participants varied significantly mainly to the broad variety of methods and assumptions applied in the assessment procedure. Based on these experiences the need of harmonisation of the procedures has been formulated as an EU research project under the 5th Framework Programme, with the aim of developing general guidelines for standardising assessments of intakes and internal doses. In the IDEAS project, eight institutions from seven European countries are participating, also using inputs from internal dosimetry professionals from across Europe to ensure broad consensus in the outcome of the project. To ensure that the guidelines are applicable to a wide range of practical situations, the first step will be to compile a database on well documented cases of internal contamination. In parallel, an improved version of existing software will be developed and distributed to the partners for further use. Many cases from the database will be evaluated independently by more partners using the same software and the results will be discussed and the draft guidelines prepared. The guidelines will then be revised and refined on the basis of the experiences and discussions of two workshops, and an inter-comparison exercise organised in the frame of the project which will be open to all internal dosimetry professionals. (author)

  4. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  5. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  6. Integrated environmental monitoring and information system

    International Nuclear Information System (INIS)

    Klinda, J.; Lieskovska, Z.

    1998-01-01

    The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included

  7. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  8. Internal monitoring of GBTx emulator using IPbus for CBM experiment

    Science.gov (United States)

    Mandal, Swagata; Zabolotny, Wojciech; Sau, Suman; Chkrabarti, Amlan; Saini, Jogender; Chattopadhyay, Subhasis; Pal, Sushanta Kumar

    2015-09-01

    The Compressed Baryonic Matter (CBM) experiment is a part of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt at GSI. In CBM experiment a precisely time synchronized fault tolerant self-triggered electronics is required for Data Acquisition (DAQ) system in CBM experiments which can support high data rate (up to several TB/s). As a part of the implementation of the DAQ system of Muon Chamber (MUCH) which is one of the important detectors in CBM experiment, a FPGA based Gigabit Transceiver (GBTx) emulator is implemented. Readout chain for MUCH consists of XYTER chips (Front end electronics) which will be directly connected to detector, GBTx emulator, Data Processing Board (DPB) and First level event selector board (FLIB) with backend software interface. GBTx emulator will be connected with the XYTER emulator through LVDS (Low Voltage Differential Signalling) line in the front end and in the back end it is connected with DPB through 4.8 Gbps optical link. IPBus over Ethernet is used for internal monitoring of the registers within the GBTx. In IPbus implementation User Datagram Protocol (UDP) stack is used in transport layer of OSI model so that GBTx can be controlled remotely. A Python script is used at computer side to drive IPbus controller.

  9. Structure health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok

    2003-01-01

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  10. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  11. Structure health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)

    2003-05-15

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  12. Structural health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok

    2003-01-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  13. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  14. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  15. Monitoring of bunker fuel consumption

    Energy Technology Data Exchange (ETDEWEB)

    Faber, J.; Nelissen, D.; Smit, M.

    2013-03-15

    Monitoring of fuel consumption and greenhouse gas emissions from international shipping is currently under discussion at the EU level as well as at the IMO (International Maritime Organization). There are several approaches to monitoring, each with different characteristics. Based on a survey of the literature and information from equipment suppliers, this report analyses the four main methods for monitoring emissions: (1) Bunker delivery notes (i.e. a note provided by the bunker fuel supplier specifying, inter alia, the amount of fuel bunkered); (2) Tank sounding (i.e. systems for measuring the amount of fuel in the fuel tanks); (3) Fuel flow meters (i.e. systems for measuring the amount of fuel supplied to the engines, generators or boilers); and (4) Direct emissions monitoring (i.e. measuring the exhaust emissions in the stack). The report finds that bunker delivery notes and tank soundings have the lowest investment cost. However, unless tank sounding is automated, these systems have higher operational costs than fuel flow meters or direct emissions monitoring because manual readings have to be entered in monitoring systems. Fuel flow meters have the highest potential accuracy. Depending on the technology selected, their accuracy can be an order of magnitude better than the other systems, which typically have errors of a few percent. By providing real-time feed-back on fuel use or emissions, fuel flow meters and direct emissions monitoring provide ship operators with the means to train their crew to adopt fuel-efficient sailing methods and to optimise their maintenance and hull cleaning schedules. Except for bunker delivery notes, all systems allow for both time-based and route-based (or otherwise geographically delineated) systems.

  16. Modification of GNPS environment radiation monitoring network system

    International Nuclear Information System (INIS)

    Jiang Lili; Cao Chunsheng

    1999-01-01

    GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition

  17. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  18. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  19. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  20. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    Science.gov (United States)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  1. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    International Nuclear Information System (INIS)

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  2. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  3. Remote monitoring: A global partnership for safeguards

    International Nuclear Information System (INIS)

    Bardsley, J.

    1996-01-01

    With increased awareness of the significant changes of the past several years and their effect on the expectations to international safeguards, it is necessary to reflect on the direction for development of nuclear safeguards in a new era and the resulting implications. The time proven monitoring techniques, based on quantitative factors and demonstrated universal application, have shown their merit. However, the new expectations suggest a possibility that a future IAEA safeguards system could rely more heavily on the value of a comprehensive, transparent, and open implementation regime. With the establishment of such a regime, it is highly likely that remote monitoring will play a significant role. Several states have seen value in cooperating with each other to address the many problems associated with the remote interrogation of integrated monitoring systems. As a consequence the International Remote Monitoring Project was organized to examine the future of remote monitoring in International Safeguards. This paper provides an update on the technical issues, the future plans, and the safeguards implications of cooperative programs relating to remote monitoring. Without providing answers to the policy questions involved, it suggests that it is timely to begin addressing these issues

  4. The pre-operational monitoring - how useful are recommendations of international organizations and various national programs

    International Nuclear Information System (INIS)

    Mihailovic, M.

    1980-01-01

    National legislation and the preoperational monitoring program around Nuclear Power Plant Krsko are described. The usefulness of international recommendations and various national preoperational monitoring programs is examined. Modifications are described which were introduced with the aim of identifying the site specific critical exposure pathways. The role of qualified and experienced experts is discussed. (H.K.)

  5. The problems of individual monitoring for internal exposure of monazite storage facility workers

    International Nuclear Information System (INIS)

    Ekidin, A.; Kirdin, I.; Yarmoshenko, I.; Zhukovsky, M.

    2006-01-01

    traditionally two situations of internal inhalation exposure by alpha emitting nuclides are considered in radiological protection: occupational exposure due to inhalation of plutonium aerosols; inhalation exposure by 222 Rn daughters in working places and in home. for these situations the problems of radioactive aerosols intake, nuclide dynamics in human body, internal dosimetry, nuclide excretion, monitoring of internal exposure have been investigated in details especially for plutonium inhalation exposure. The results of these studies are presented in details in ICRP Publications and UNSCEAR reports. However there is very specific case in which the special analysis of internal inhalation exposure is need. it is the working places with anomalous, extremely high concentration of thoron ( 220 Rn) daughters. The problems of internal radiation exposure of workers in such working place are the main topic of this publication. (authors)

  6. Non-invasive system for monitoring of the manufacturing equipment

    Science.gov (United States)

    Mazăre, A. G.; Belu, N.; Ionescu, L. M.; Rachieru, N.; Misztal, A.

    2017-08-01

    The automotive industry is one of the most important industries in the world that concerns the economy and the world culture. High demand has resulted in increasing of the pressure on the production lines. In conclusion, it is required more careful in monitoring of the production equipment not only for maintenance but also for staff safety and to increase the quality of production. In this paper, we propose a solution for non-invasive monitoring of the industrial equipment operation by measuring the current consumption on energy supply lines. Thus, it is determined the utilization schedule of the equipment and operation mode. Based on these measurements, it’s built an activity report for that equipment, available to the quality management and maintenance team. The solution consists of the current measuring equipment, with self-harvesting capabilities and radio transceiver, and an embedded system which run a server. The current measuring equipment will transmit data about consumption of each energy supply network line where is placed the industrial equipment. So, we have an internal measuring radio network. The embedded system will collect data for the equipment and put in a local data base and it will provide via an intranet application. The entire system not requires any supplementary energy supply and interventions in the factory infrastructure. It is experimented in a company from the automotive industries.

  7. Advanced in-core monitoring system for high-power reactors

    International Nuclear Information System (INIS)

    Mitin, V.I.; Alekseev, A.N.; Golovanov, M.N.; Zorin, A.V.; Kalinushkin, A.E.; Kovel, A.I.; Milto, N.V.; Musikhin, A.M.; Tikhonova, N.V.; Filatov, V.P.

    2006-01-01

    This paper encompasses such section as objective, conception and engineering solution for construction of advanced in-core instrumentation system for high power reactor, including WWER-1000. The ICIS main task is known to be an on-line monitoring of power distribution and functionals independently of design programs to avoid a common cause error. This paper shows in what way the recovery of power distribution has been carried out using the signals from in-core neutron detectors or temperature sensors. On the basis of both measured and processed data, the signals of preventive and emergency protection on local parameters (linear power of the maximum intensive fuel rods, departure from nucleate boiling ratio peaking factor) have been automatically generated. The paper presents a detection technology and processing methods for signals from SPNDs and TCs, ICIS composition and structure, computer hardware, system and applied software. Structure, composition and the taken decisions allow combining class IE and class B and C tasks in accordance with international standards of separation and safety category realization. Nowadays, ICIS-M is a system that is capable to ensure: monitoring, safety, information display and diagnostics function, which allow securing actual increase of quality, reliability and safety in operation of nuclear fuel and power units. Meanwhile, it reduce negative influence of human factor on thermal technical reliability in the operational process (Authors)

  8. The system of personal monitoring and the evaluation of occupational exposure to external ionizing radiation in Cuba

    International Nuclear Information System (INIS)

    Molina, Daniel; Castro, Ailza; Martinez, Ernesto; Pernas, Rene

    2008-01-01

    Full text: Personal monitoring of workers is recommended or required by the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. In our country the personal monitoring of external exposure to ionizing radiation is carried out by External Dosimetry Laboratory (LDE) of the Center for Radiation Protection and Hygiene (CPHR). We have implemented an individual monitoring service based on thermoluminescence dosimetry system. The service includes whole body and extremity dosimeters. We have two systems; one is base on a manual Toledo TLD reader and the other on an automatic RADOS TLD system. This service is recognized by the National Regulatory Authority in the field of radiation protection and safety. We have implemented a quality assurance (QA) programme designed according to the recommendations of the ISO/IEC 17025 standards. The papers deals with the presentation of these QA programme which includes administrative data and information, technical checking of the equipment, acceptance tests of new dosimeters and equipment, issuing and processing of the dosimeters, dose evaluation, record keeping and reporting, traceability, handling of complaints, internal reviews and external audits. The papers also describe the results of occupational exposure for the different practices during 2006-2007 period. (author)

  9. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  10. Hybrid Wireless Hull Monitoring System for Naval Combat Vessels

    Science.gov (United States)

    2010-03-01

    Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system

  11. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  12. An approach to routine individual internal dose monitoring at the object 'Shelter' personnel considering uncertainties

    International Nuclear Information System (INIS)

    Mel'nichuk, D.V.; Bondarenko, O.O.; Medvedjev, S.Yu.

    2002-01-01

    An approach to organisation of routine individual internal dose monitoring of the personnel of the Object 'Shelter' is presented in the work, that considers individualised uncertainties. In this aspect two methods of effective dose assessment based on bioassay are considered in the work: (1) traditional indirect method at which application results of workplace monitoring are not taken into account, and (2) a combined method in which both results of bioassay measurements and workplace monitoring are considered

  13. The Dams and Monitoring Systems and Case Study: Ataturk and Karakaya Dams

    Science.gov (United States)

    Kalkan, Y.; Bilgi, S.; Gülnerman, A. G.

    2017-12-01

    Dams are among the most important engineering structures used for flood controls, agricultural purposes as well as drinking and hydroelectric power. Especially after the Second World War, developments on the construction technology, increase the construction of larger capacity dams. There are more than 150.000 dams in the world and almost 1000 dams in Turkey, according to international criteria. Although dams provide benefits to humans, they possess structural risks too. To determine the performance of dams on structural safety, assessing the spatial data is very important. These are movement, water pressure, seepage, reservoir and tail-water elevations, local seismic activities, total pressure, stress and strain, internal concrete temperature, ambient temperature and precipitation. These physical data are measured and monitored by the instruments and equipment. Dams and their surroundings have to be monitored by using essential methods at periodic time intervals in order to determine the possible changes that may occur over the time. Monitoring programs typically consist of; surveillance or visual observation. These programs on dams provide information for evaluating the dam's performance related to the design intent and expected changes that could affect the safety performance of the dam. Additionally, these programs are used for investigating and evaluating the abnormal or degrading performance where any remedial action is necessary. Geodetic and non-geodetic methods are used for monitoring. Monitoring the performance of the dams is critical for producing and maintaining the safe dams. This study provides some general information on dams and their different monitoring systems by taking into account two different dams and their structural specifications with the required information. The case study in this paper depends on a comparison of the monitoring surveys on Atatürk Dam and Karakaya Dam, which are constructed on Firat River with two different structural

  14. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  15. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  16. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  17. Monitoring of international normalized ratios: comparison of community nurses with family physicians.

    Science.gov (United States)

    Levine, Max A; Shao, Wei; Klein, Douglas

    2012-08-01

    To determine whether community-based, nurse-led monitoring of the international normalized ratio (INR) in patients requiring long-term warfarin therapy was comparable to traditional physician monitoring. A retrospective cohort analysis of patients taking long-term warfarin therapy. The study used data gathered from 3 family medicine clinics in a primary care network in Edmonton, Alta. Medical records of patients currently taking warfarin were examined. Implementation of nurse-led monitoring in a primary care network in place of standard family physician INR monitoring. The degree of INR control before and after the implementation of nurse-run INR monitoring was assessed. The average proportion of time spent outside of therapeutic INR ranges, as well as the average number of days between successive INR readings, was calculated and compared. The degree of control placed patients into either a good-control group (out of range ≤ 25% of the time) or a moderate-control group (out of range > 25% of the time) and these groups were compared. Before nurse monitoring, INR values were out of range 20.4% of the time; after nurse monitoring they were out of range 19.2% of the time (P = .115); the time between sequential INR readings also did not differ before and after implementation of nurse monitoring (23.9 vs 21.6 days, P = .789). Nurse-led monitoring of INR is as effective as traditional physician monitoring. Advantages of nurse-led monitoring might include freeing family physicians to see more patients or to spend less time at work. It might also represent potential cost savings.

  18. Development of an Experimental African Drought Monitoring and Seasonal Forecasting System: A First Step towards a Global Drought Information System

    Science.gov (United States)

    Wood, E. F.; Chaney, N.; Sheffield, J.; Yuan, X.

    2012-12-01

    Extreme hydrologic events in the form of droughts are a significant source of social and economic damage. Internationally, organizations such as UNESCO, the Group on Earth Observations (GEO), and the World Climate Research Programme (WCRP) have recognized the need for drought monitoring, especially for the developing world where drought has had devastating impacts on local populations through food insecurity and famine. Having the capacity to monitor droughts in real-time, and to provide drought forecasts with sufficient warning will help developing countries and international programs move from the management of drought crises to the management of drought risk. While observation-based assessments, such as those produced by the US Drought Monitor, are effective for monitoring in countries with extensive observation networks (of precipitation in particular), their utility is lessened in areas (e.g., Africa) where observing networks are sparse. For countries with sparse networks and weak reporting systems, remote sensing observations can provide the real-time data for the monitoring of drought. More importantly, these datasets are now available for at least a decade, which allows for the construction of a climatology against which current conditions can be compared. In this presentation we discuss the development of our multi-lingual experimental African Drought Monitor (ADM) (see http://hydrology.princeton.edu/~nchaney/ADM_ML). At the request of UNESCO, the ADM system has been installed at AGRHYMET, a regional climate and agricultural center in Niamey, Niger and at the ICPAC climate center in Nairobi, Kenya. The ADM system leverages off our U.S. drought monitoring and forecasting system (http://hydrology.princeton.edu/forecasting) that uses the NLDAS data to force the VIC land surface model (LSM) at 1/8th degree spatial resolution for the estimation of our soil moisture drought index (Sheffield et al., 2004). For the seasonal forecast of drought, CFSv2 climate

  19. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  20. PMT Dark Noise Monitoring System for Neutrino Detector Borexino Based on the Devicenet Protocol and WEB-Access

    International Nuclear Information System (INIS)

    Chepurnov, A.S.; Orekhov, D.I.; Maimistov, D.A.; Sabelnikov, A.A.; Etenko, A.V.

    2006-01-01

    Monitoring of PMT dark noise in a neutrino detector BOREXINO is a procedure that indicates condition of the detector. Based on CAN industrial network, top level DeviceNet protocol and WEB visualization, the dark noise monitoring system having 256 channels for the internal detector and for the external muon veto was created. The system is composed as a set of controllers, converting the PMT signals to frequency and transmitting them over Can network. The software is the stack of the DeviceNet protocols, providing the data collecting and transporting. Server-side scripts build web pages of user interface and graphical visualization of data

  1. Monitoring support system for nuclear power plant

    International Nuclear Information System (INIS)

    Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki

    1996-01-01

    The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)

  2. Beacon-Colss core monitoring system application and benefits

    International Nuclear Information System (INIS)

    Boyd, W.A.; Yoon, T.Y.

    2005-01-01

    Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)

  3. Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji

    1981-07-01

    In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)

  4. An evaluation of an attendance monitoring system for undergraduate nursing students.

    Science.gov (United States)

    Doyle, Louise; O'Brien, Frances; Timmins, Fiona; Tobin, Gerard; O'Rourke, Frank; Doherty, Lena

    2008-03-01

    Internationally the preparation and ongoing education of nurses continues to evolve in response the changing nature of both nursing and health care. The move into third level structures that has taken place in countries such as the UK and the Republic of Ireland, results in new challenges to the historical fabric of nurse education. One such challenge is monitoring of nursing students' attendance. Viewed by students as a patriarchal and draconian measure, the nursing profession historically value their ability to ensure the public and professional bodies that nursing students fully engage with educational programmes. University class sizes and the increased perception of student autonomy can negate against formalised monitoring systems. This paper reports on an evaluation of one such monitoring system. The findings revealed that attendance was recognised implicitly by nurse educators as an important learning activity within these programmes results and that current methods employed were less than reliable and so did little to appropriately control the phenomenon. Subsequent to the evaluation; a standardised approach to the measurement of absenteeism was employed. Deliberate short-term absence was a feature of this group. Reasons cited included travelling long distances, dissatisfaction with programme timetables and personal reasons. Preventative measures employed included improvement in student timetable delivery.

  5. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  6. A radiation monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  7. Monitoring Distributed Real-Time Systems: A Survey and Future Directions

    Science.gov (United States)

    Goodloe, Alwyn E.; Pike, Lee

    2010-01-01

    Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.

  8. Automated Cryocooler Monitor and Control System Software

    Science.gov (United States)

    Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad

    2011-01-01

    This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

  9. Radiation Internal Monitoring by In Vivo Scanning in Operation Tomodachi

    Science.gov (United States)

    2013-08-01

    detected at the International Monitoring Station (IMS), Takasaki (Gunma Prefecture, about 210 km (130 miles) WSW of FDNPS) during the period March...determine a dose from both inhalation and ingestion. Based on additional information on food and water sources for DOD-affiliated individuals it was...kBq Tritium 0.06 pg 23 Bq Polonium 0.2 pg 37 Bq * Source is Eckerman and Sjoreen (2003). As discussed in Section 2.2.4 and calculated with the

  10. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  11. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  12. Propose Reactor Control and Monitoring System for RTP

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha

    2011-01-01

    Reactor control and monitoring system is a one of the important features used in reactor. The control and monitoring must come together to provide safety, excellent performance and reliable in nuclear reactor technology application. Objectives of this technical paper are to design and propose reactor control system and reactor monitoring system in Research Reactor (RTP) for Reactor Upgrading Project. (author)

  13. Environmental, political, and economic determinants of water quality monitoring in Europe

    Science.gov (United States)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  14. Water monitoring and its information management system in China; Chugoku ni okeru suishitsu monitoring to joho kanri system

    Energy Technology Data Exchange (ETDEWEB)

    Quan, H.

    1996-01-10

    This paper summarizes the water monitoring system (WMS) in China applied mainly to surface water and operated within the competence of the Environmental Protection Agency. The WMS consists of a national water monitoring network and a water information system that monitors surface water periodically. The WMS comprises water monitoring stations classified from class 1 to class 4, which are located in 2,222 locations. Stations from class 1 to class 3 are operated by using computers, but class 4 stations are still incapable to use floppy disks to perform information transmission. When an information management system is completed at the China-Japan Friendship Environmental Protection Center being constructed by gratis assistance from the Japanese Government, transmission of water quality data will become possible by means of the cable line system in addition to the table system and the floppy system. The water quality data are published to general people in the forms of Chinese gazette for the environmental conditions, the environment yearbook, and the reports on environmental quality. However, the more important is to publish more publications to make people aware of the actual state of water pollution and have them cooperate in environment preservation. 4 refs., 1 fig.

  15. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  16. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  17. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  18. Preliminry results of the 1975 international personnel monitoring survey

    International Nuclear Information System (INIS)

    Becker, K.

    1975-11-01

    About 70 detailed questions have been answered in mid-1975 by 83 personnel monitoring services in 33 countries, representing almost half a million, or approximately 28 percent, of the world's total radiation workers, as well as by 11 customers of U. S. commercial services. Extensive data are given on many questions regarding the current system in use, future plans, and experiences, for example on the type(s) of TLD, film and readout instrumentation; monitoring period; applications for extremity and environmental monitoring; advantages and disadvantages of various systems; R and D projects; experience with beta and neutron dosimetry; intentional fake exposures; lower and upper dose limits; recordkeeping; and reporting of the results. The larger services in the advanced countries lead in the transition from film to TLD. More than half of the radiation workers already wear TLDs, or will do so within about two years. Important unsolved problems are fast neutron monitoring and the low information content and high initial cost of TLD. The trend is towards large, centralized, automatic services and recordkeeping, with extensive computer use for evaluation and data handling. There is a need for better performance standards and testing, and more information exchange and cooperation between services. (auth)

  19. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  20. Listening to Yourself Is like Listening to Others: External, but Not Internal, Verbal Self-Monitoring Is Based on Speech Perception

    Science.gov (United States)

    Huettig, Falk; Hartsuiker, Robert J.

    2010-01-01

    Theories of verbal self-monitoring generally assume an internal (pre-articulatory) monitoring channel, but there is debate about whether this channel relies on speech perception or on production-internal mechanisms. Perception-based theories predict that listening to one's own inner speech has similar behavioural consequences as listening to…

  1. Program of individual monitoring of the internal contamination and their implementation in the Republic the Cuba

    International Nuclear Information System (INIS)

    Lopez Bejerano, Gladys M.; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Acosta Rodriguez, Nancy; Carrazana Gonzalez, Jorge A.; Cruz Suarez, Rodolfo

    2008-01-01

    Full text: In different Cuban institutions linked fundamentally to the medical practice of nuclear medicine and the investigations, it is worked with sources open of ionizing radiations, that which makes indispensable the existence of a system of radiological surveillance that includes the control radiological individual of the received doses as a result of the occupational, such exhibition that is guaranteed that the exhibition of the Hard-working Exposed Occupationally, stay inside the recommended limits, in the International Basic Norms of Protection against the Ionizing radiations and safe-deposit of the Sources of Radiation (NBIS) and in turn adopted in the Norma Cuban. From the year 1986 in the Center of Protection and Hygiene of the Radiations is carried out in way centralized this control; but with the inconvenience of not being able to carry out the same one to workers from the domestic interior when not being feasible the transfer of these toward its headquarters, reason why the doses were ignored received in an important number of these. In and of itself the Laboratory of Internal Contamination of this institution in these years has developed managed works to define firstly, for each institution, the program of monitoring of the internal contamination of its workers using for it the methodology recommended by the OIEA where the potential doses are evaluated that for incorporation these they receive and whose results suggested the introduction of a program of individual monitoring as behavior to continue in most of the institutions. In correspondence with it was designed and established a program that included the study of feasibility of the existent equipment in the institutions to carry out the monitoring of the internal contamination using technical of measuring in vivo and in vitro, as it corresponds, their calibration, the establishment of procedures that respond to the requirements of a System of Quality for the Norma ISO/IEC 17025 and

  2. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  3. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  4. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  5. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  6. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  7. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  8. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  9. Internationally coordinated glacier monitoring - a timeline since 1894

    Science.gov (United States)

    Nussbaumer, Samuel U.; Armstrong, Richard; Fetterer, Florence; Gärtner-Roer, Isabelle; Hoelzle, Martin; Machguth, Horst; Mölg, Nico; Paul, Frank; Raup, Bruce H.; Zemp, Michael

    2016-04-01

    Changes in glaciers and ice caps provide some of the clearest evidence of climate change, with impacts on sea-level variations, regional hydrological cycles, and natural hazard situations. Therefore, glaciers have been recognized as an Essential Climate Variable (ECV). Internationally coordinated collection and distribution of standardized information about the state and change of glaciers and ice caps was initiated in 1894 and is today organized within the Global Terrestrial Network for Glaciers (GTN-G). GTN-G ensures the continuous development and adaptation of the international strategies to the long-term needs of users in science and policy. A GTN-G Steering Committee coordinates, supports and advices the operational bodies responsible for the international glacier monitoring, which are the World Glacier Monitoring Service (WGMS), the US National Snow and Ice Data Center (NSIDC), and the Global Land Ice Measurements from Space (GLIMS) initiative. In this presentation, we trace the development of the internationally coordinated glacier monitoring since its beginning in the 19th century. Today, several online databases containing a wealth of diverse data types with different levels of detail and global coverage provide fast access to continuously updated information on glacier fluctuation and inventory data. All glacier datasets are made freely available through the respective operational bodies within GTN-G, and can be accessed through the GTN-G Global Glacier Browser (http://www.gtn-g.org/data_browser.html). Glacier inventory data (e.g., digital outlines) are available for about 180,000 glaciers (GLIMS database, RGI - Randolph Glacier Inventory, WGI - World Glacier Inventory). Glacier front variations with about 45,000 entries since the 17th century and about 6,200 glaciological and geodetic mass (volume) change observations dating back to the 19th century are available in the Fluctuations of Glaciers (FoG) database. These datasets reveal clear evidence that

  10. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  11. Monitoring the International Monetary System: Its Development in the West, and Future in the East

    Directory of Open Access Journals (Sweden)

    Todd J. Barry

    2016-06-01

    Full Text Available The “gold standard” is frequently mentioned in text books, but few without an economics background can fully understand it. This paper thus begins in 1896, when U.S. Presidential candidate William Jennings Bryan declared, “You shall not crucify mankind on a cross of gold.” Since going back to the middle ages, the world has had numerous monetary systems, which are here explained in comprehensible terms. A modern reoccurring idea is to return to some form of the gold standard, while some argue for switching to the Chinese yuan or another international reserve currency, which the International Monetary Fund (IMF will adopt in their Special Drawing Rights starting in October, 2016. This paper is normative in that it comments on the current international structure, but uses economic principles to support its argument in favor of an internationally strong dollar. It thus traces the history of a topically contentious subject, with a basic regression indicating important predictive factors for the future. It offers that a new gold standard would not be in the world’s interest, interfering with monetary policy, while emerging market countries would be best to import more and financially deepen, which the regression shows was why the Chinese yuan was adopted by the IMF, then looking ahead to other parts of Asia and towards bitcoins.

  12. Monitoring system for OpenPBS environment

    Energy Technology Data Exchange (ETDEWEB)

    Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)

    2004-11-21

    The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.

  13. Economic analysis of condition monitoring systems for offshore wind turbine sub-systems

    DEFF Research Database (Denmark)

    May, Allan; MacMillan, David; Thöns, Sebastian

    2015-01-01

    The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...... and their associated costs has been completed for the blades, drive train, tower and foundation. This paper considers what value can be obtained from integrating these additional systems into the maintenance plan. This is achieved by running simulations on an operations and maintenance model for a wind farm over a 20...

  14. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  15. Wide-area, real-time monitoring and visualization system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  16. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  17. RFID and IOT for Attendance Monitoring System

    Directory of Open Access Journals (Sweden)

    Dedy Irawan Joseph

    2018-01-01

    Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.

  18. A New Environmental Monitoring System For Silkworm Incubators

    OpenAIRE

    Alejandra Duque-Torres; Juan Ruiz-Rosero; Gesille Zambrano-Gonzalez; Martha Almanza-Pinzon; Oscar Mauricio Caicedo Rendon; Gustavo Ramirez-Gonzalez

    2018-01-01

    A newly Monitoring Environmental Conditions System is proposed based on Raspberry-Pi. This proposal monitors the temperature, humidity, and luminosity in a silkworm incubator. The monitoring data are collected and save in the cloud for the subsequent analysis. The monitoring environmental system is based on Raspberry Pi due to capabilities, features, and low cost. The preliminary tests were realized in a real scenery and the results demonstrating its reliability.

  19. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  20. ZPR-9 airborne plutonium monitoring system

    International Nuclear Information System (INIS)

    Rusch, G.K.; McDowell, W.P.; Knapp, W.G.

    1975-01-01

    An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved

  1. Development of the simulation monitoring system

    International Nuclear Information System (INIS)

    Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo

    2001-01-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)

  2. Progress and monitoring system on compression and transmission technologies of dynamic image

    International Nuclear Information System (INIS)

    Kobayashi, Hiroyuki; Saijo, Nobuyuki; Nakajo, Ken

    2001-01-01

    The Toshiba Corporation developed a real-time dynamic image transmission matched with quality of transmission circuit by using MPEG-4 which was recent international standard system for the dynamic image coding system. Concretely, this system made possible on real-time dynamic image transmission even at transmission on wireless circuit such as portable telephone, PHS, wireless LAN, and so on, at viewpoint of the mobile communication. And, by using the wireless circuit, it could be built without any limit of transmission cable, to realize its layout-free establishment. In addition, this system uses only image for communication without using voice, and some devices were carried out to upgrade image and frame speed as possible. Here were described on outlines of transmission system and principle of detection MPEG-4, and function and application of monitoring system using this system. (G.K.)

  3. Application of Video Recognition Technology in Landslide Monitoring System

    Directory of Open Access Journals (Sweden)

    Qingjia Meng

    2018-01-01

    Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.

  4. Laboratory information management system: an example of international cooperation in Namibia.

    Science.gov (United States)

    Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo

    2012-01-01

    The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  5. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  6. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  7. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  8. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  9. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  10. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  11. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  12. A Multisampling Reporter System for Monitoring MicroRNA Activity in the Same Population of Cells

    Directory of Open Access Journals (Sweden)

    Pei-Chen Huang

    2009-01-01

    Full Text Available MicroRNAs (miRNAs downregulate gene expression by binding to the partially complementary sites in the 3′ untranslated region (UTR of target mRNAs. Several methods, such as Northern blot analysis, quantitative real-time RT-PCR, microarray, and the luciferase reporter system, are commonly used to quantify the relative level or activity of miRNAs. The disadvantage of these methods is the requirement for cell lysis, which means that several sets of wells/dishes of cells must be prepared to monitor changes in miRNA activity in time-course studies. In this study, we developed a multisampling reporter system in which two secretable bioluminescence-generating enzymes are employed, one as a reporter and the other as an internal control. The reporters consist of a pair of vectors containing the Metridia luciferase gene, one with and one without a duplicated miRNA targeting sequence at their 3′UTR, while the other vector coding for the secreted alkaline phosphatase gene is used as an internal control. This method allows miRNA activity to be monitored within the same population of cells over time by withdrawing aliquots of the culture medium. The practicability and benefits of this system are addressed in this report.

  13. Timing and control monitor system upgrade design document. Version 4

    International Nuclear Information System (INIS)

    Brandt, J.J.

    1984-01-01

    This is a design document for the Timing and Control Monitor System Upgrade Project. This project is intended to provide a replacement system for the existing user Encoder Monitor Systems and Varian 72 Control Room computer systems. All of these systems reside at the Nevada Test Site. The function of the T and C Monitor System is to gather real-time statistics and data on user defined key variables from control, communication, data acquistion systems, and from the monitoring system itself. The control, communication, and data acquisition systems each operate separately from the monitor system. The T and C Monitor System gathers this data in order to verify the readiness of an event to begin countdown. This includes setup, verification, calibration, and peripheral services, report any failures that may occur during the countdown, verify detonation and containment, and assist reentry activities after the event

  14. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  15. Reactor internals vibration monitoring by neutron noise methods in PWRs

    International Nuclear Information System (INIS)

    Pazsit, I.; Por, G.; Lux, I.

    1983-01-01

    Certain elements of PWR cores such as control/fuel rods or cassettes, or other parts of reactor internals, often represent a vibration problem. Early analyses at operating PWR plant revealed that these vibrations can be detected by in-core neutron detectors, opening up the possibility of vibration monitoring and diagnostics by noise methods. Theoretical methods of calculating vibration induced neutron noise and its application to vibration diagnostics are summarized. Experiments to check theoretical conclusions are under way at the Central Research Institute for Physics, Budapest. (author)

  16. Supervisory monitoring system in nuclear power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1997-01-01

    Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs

  17. International research to monitor sustainable forest spatial patterns: proceedings of the 2005 IUFRO World Congress symposium

    Science.gov (United States)

    Kurt Riitters; Christine Estreguil

    2007-01-01

    Presentations from the symposium "International Research to Monitor Sustainable Forest Spatial Patterns," which was organized as part of the International Union of Forest Research Organizations (IUFRO) World Congress in August 2005, are summarized in this report. The overall theme of the World Congress was "Forests in the Balance: Linking Tradition and...

  18. The Russian experience of monitoring technologies

    International Nuclear Information System (INIS)

    Kolesnikov, A.L.

    1999-01-01

    The implementation of nuclear test monitoring, the observance of international nuclear weapon limitation and test ban agreements is assigned to the Special Monitoring Service at the Ministry of defence in Russian Federation. The system of collecting, processing, analysis and generalization of the data on nuclear tests has been created and is functioning in the Special Monitoring Service. This system is based on the application of the facilities of the seismic, infra sound, radionuclide and other monitoring methods. The Service has all the necessary scientific and technical basis, the perfect mechanism for solving the monitoring problems. Its activities cover data collecting and processing centres as well as special monitoring laboratory equipment, integrated in the unified computer aide system. Besides the experiences of the Russian Service, the possible ways of cooperation with CTBTO are described

  19. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  20. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  1. Soil monitoring as a part of environment monitoring in Slovakia

    International Nuclear Information System (INIS)

    Kobza, J.

    1997-01-01

    In frame of Soil monitoring system it is going about a lot of methods in advance as follows: methods of soil monitoring sites selection and soil monitoring network construction, as well; methods of soil survey and soil sampling; analytical methods (indicating of chemical, agrochemical and physical properties); soil database and methods of evaluation and interpretation of measured results. The monitoring network was constructed on the base of ecological principles - including the monitoring of all soil types and subtypes, various climatic and emission regions as well as relatively clean regions, lowland and highland. Soil monitoring network in forest land is regular (8 x 8 km) with regard to International monitoring system in Forestry. The soil monitoring network in Slovakia consist of 650 monitoring sites (312 sites in farming land and 338 sites in forest land). In addition soil monitoring network includes also 21 monitoring sites. All monitoring sites are geodesically located and reported on the map at a scale of 1:5000. There are the methods concerning the important soil parameters indication with regard to main soil degradation processes a s follows: soil contamination (heavy metals and organic contaminants); soil acidification; soil salinity; soil erosion (deluometrically by the Cs-137 and remote sensing methods); soil compaction; soil fertility and protection. Analytical control system was elaborated according to Good Laboratory Practice. Evaluation of soil monitoring network results is not simple because it depends on various monitored parameters, on aim of evaluation as well as on the scale of landscape which is object for evaluation. There are used the modern statistical methods in monitoring system which can be: universal; disjunctive; simulated. Used statistical methods are significant for interpretation of measured results as follows: trends in landscape; anisotropy; comparison. The evaluation and interpretation way is very significant with regard not

  2. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  3. Towards a geophysical decision-support system for monitoring and managing unstable slopes

    Science.gov (United States)

    Chambers, J. E.; Meldrum, P.; Wilkinson, P. B.; Uhlemann, S.; Swift, R. T.; Inauen, C.; Gunn, D.; Kuras, O.; Whiteley, J.; Kendall, J. M.

    2017-12-01

    Conventional approaches for condition monitoring, such as walk over surveys, remote sensing or intrusive sampling, are often inadequate for predicting instabilities in natural and engineered slopes. Surface observations cannot detect the subsurface precursors to failure events; instead they can only identify failure once it has begun. On the other hand, intrusive investigations using boreholes only sample a very small volume of ground and hence small scale deterioration process in heterogeneous ground conditions can easily be missed. It is increasingly being recognised that geophysical techniques can complement conventional approaches by providing spatial subsurface information. Here we describe the development and testing of a new geophysical slope monitoring system. It is built around low-cost electrical resistivity tomography instrumentation, combined with integrated geotechnical logging capability, and coupled with data telemetry. An automated data processing and analysis workflow is being developed to streamline information delivery. The development of this approach has provided the basis of a decision-support tool for monitoring and managing unstable slopes. The hardware component of the system has been operational at a number of field sites associated with a range of natural and engineered slopes for up to two years. We report on the monitoring results from these sites, discuss the practicalities of installing and maintaining long-term geophysical monitoring infrastructure, and consider the requirements of a fully automated data processing and analysis workflow. We propose that the result of this development work is a practical decision-support tool that can provide near-real-time information relating to the internal condition of problematic slopes.

  4. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  5. Activity monitoring systems in health care

    NARCIS (Netherlands)

    Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.

    2011-01-01

    This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After

  6. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  7. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  8. Statistical Analysis of Stress Signals from Bridge Monitoring by FBG System

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Ye

    2018-02-01

    Full Text Available In this paper, a fiber Bragg grating (FBG-based stress monitoring system instrumented on an orthotropic steel deck arch bridge is demonstrated. The FBG sensors are installed at two types of critical fatigue-prone welded joints to measure the strain and temperature signals. A total of 64 FBG sensors are deployed around the rib-to-deck and rib-to-diagram areas at the mid-span and quarter-span of the investigated orthotropic steel bridge. The local stress behaviors caused by the highway loading and temperature effect during the construction and operation periods are presented with the aid of a wavelet multi-resolution analysis approach. In addition, the multi-modal characteristic of the rainflow counted stress spectrum is modeled by the method of finite mixture distribution together with a genetic algorithm (GA-based parameter estimation approach. The optimal probability distribution of the stress spectrum is determined by use of Bayesian information criterion (BIC. Furthermore, the hot spot stress of the welded joint is calculated by an extrapolation method recommended in the specification of International Institute of Welding (IIW. The stochastic characteristic of stress concentration factor (SCF of the concerned welded joint is addressed. The proposed FBG-based stress monitoring system and probabilistic stress evaluation methods can provide an effective tool for structural monitoring and condition assessment of orthotropic steel bridges.

  9. Efficient network monitoring for large data acquisition systems

    International Nuclear Information System (INIS)

    Savu, D.O.; Martin, B.; Al-Shabibi, A.; Sjoen, R.; Batraneanu, S.M.; Stancu, S.N.

    2012-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed realtime data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and seamlessly integrates complementary data from auxiliary tools, such as NAGIOS, information services or custom databases. A number of techniques (e.g. normalization, aggregation and data caching) were used in order to improve the user interface response time. The end result is a unified monitoring interface, for fast and uniform access to system statistics, which significantly reduced the time spent by experts for ad-hoc and post-mortem analysis. (authors)

  10. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  11. User interface design and system integration aspects of core monitoring systems

    International Nuclear Information System (INIS)

    Berg, O.; Bodal, T.; Hornaes, A.; Porsmyr, J.

    2000-01-01

    The present paper describes our experience with the SCORPIO core monitoring system using generic building blocks for the MMI and system integration. In this context the different layers of the software system are discussed starting with the communication system, interfacing of various modules (e.g. physics codes), administration of several modules and generation of graphical user interfaces for different categories of end-users. A method by which re-use of software components can make the system development and maintenance more efficient is described. Examples are given from different system installation projects. The methodology adopted is considered particularly important in the future, as it is anticipated that core monitoring systems will be expanded with new functions (e.g. information from technical specifications, procedures, noise analysis, etc). Further, efficient coupling of off-line tools for core physics calculations and on-line modules in core monitoring can pave the way for cost savings. (authors)

  12. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  13. Monitoring compliance with the International Code of Marketing of Breastmilk Substitutes in west Africa: multisite cross sectional survey in Togo and Burkina Faso.

    Science.gov (United States)

    Aguayo, Victor M; Ross, Jay S; Kanon, Souleyman; Ouedraogo, Andre N

    2003-01-18

    To monitor compliance with the International Code of Marketing of Breastmilk Substitutes in health systems, sales outlets, distribution points, and the news media in Togo and Burkina Faso, west Africa. Multisite cross sectional survey. Staff at 43 health facilities and 66 sales outlets and distribution points, 186 health providers, and 105 mothers of infants aged market commercial breast milk substitutes were found in 29 (44%) sales and distribution points. Forty commercial breast milk substitutes violated the labelling standards of the code: 21 were manufactured by Danone, 11 by Nestlé, and eight by other national and international manufacturers. Most (148, 90%) health providers had never heard of the code, and 66 mothers (63%) had never received any counselling on breast feeding by their health providers. In west Africa manufacturers are violating the code of marketing of breast milk substitutes. Comparable levels of code violations are observed with (Burkina Faso) or without (Togo) regulating legislation. Legislation must be accompanied by effective information, training, and monitoring systems to ensure that healthcare providers and manufacturers comply with evidence based practice and the code.

  14. MONITORING IN CREDIT INSTITUTIONS – COMPARATIVE APPROACH ON INTERNAL CONTROL SYSTEMS – THE CASE OF ROMANIA VS. INTERNATIONAL MODELS OF CONTROL

    Directory of Open Access Journals (Sweden)

    MURESAN MARIANA

    2010-07-01

    Full Text Available Starting from the stipulations of the two well-known internal control system models – COSO and CoCo - the purpose of this paper is to focus on the Romanian framework for credit institutions – trying to to identify on which international model is our national one most appropriate to. The research methodology is based on an empirical analysis between Romanian regulation and the models already mentioned. To reach to a conclusion we tried to identify several key issues closely related to information and communication, and to determine the degree of similarities and dissimilarities between the three selected frameworks, by using statistical indicators. The paper has some limitations, too, because it only approaches formal harmonization. So, those issues analyzed through the regulations’ perspectives need to be closely quantified in matters of their actual implementation, which offer us outlooks of future research.

  15. 296-B-10 stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1995-01-01

    B Plant Administration Manual, requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with stack 296-B-10 at B Plant. The ventilation system of WESF (Waste Encapsulation and Storage Facility) is designed to provide airflow patterns so that air movement throughout the building is from areas of lesser radioactivity to areas of greater radioactivity. All potentially contaminated areas are maintained at a negative pressure with respect to the atmosphere so that air flows into the building at all times. The exhaust discharging through the 296-B-10 stack is continuously monitored and sampled using a sampling and monitoring probe assembly located approximately 17.4 meters (57 feet) above the base of the stack. The probe assembly consists of 5 nozzles for the sampling probe and 2 nozzles to monitor the flow. The sampling and monitoring system associated with Stack 296-B-10 is functional and performing satisfactorily

  16. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  17. Data analysis for remote monitoring of safeguarded facilities

    International Nuclear Information System (INIS)

    DeLand, S.M.

    1997-01-01

    The International Remote Monitoring Project (IRMP) sponsored by the US DOE allows DOE and its international partners to gain experience with the remote collection, transmission, and interpretation of safeguards-relevant data. This paper focuses on the interpretation of the data from these remote monitoring systems. Users of these systems need to be able to ascertain that the remote monitoring system is functioning as expected and that the events generated by the sensors are consistent with declared activity. The initial set of analytical tools being provided for IRMP installations this year include a suite of automatically generated views of user-selected data. The baseline set of tools, with illustrative examples, will be discussed. Plans for near-term enhancements will also be discussed. Finally, the applicability of more advanced analytical techniques such as expert systems will be discussed

  18. Sustainable Innovation, Management Accounting and Control Systems, and International Performance

    Directory of Open Access Journals (Sweden)

    Ernesto Lopez-Valeiras

    2015-03-01

    Full Text Available This study analyzes how Management Accounting and Control Systems (MACS facilitate the appropriation of the benefits of sustainable innovations in organizations. In particular, this paper examines the moderating role of different types of MACS in the relationships between sustainable innovation and international performance at an organizational level. We collected survey data from 123 Spanish and Portuguese organizations. Partial Least Square was used to analyze the data. Results show that the effect of sustainable innovations on international performance is enhanced by contemporary rather than traditional types of MACS. Overall our findings show that MACS can help managers to develop and monitor organizational activities (e.g., costumer services and distribution activities, which support the appropriation of the potential benefits from sustainable innovation. This paper responds to recent calls for in-depth studies about the organizational mechanism that may enhance the success of sustainable innovation.

  19. Sistem Evaluasi Jamunan Mutu Menggunakan Rule Based System Untuk Monitoring Mutu Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Sri Hartono

    2017-05-01

    Full Text Available The needs for continuous quality improvement resulting in the more complex. The research aims to develop system of quality assurance evaluation using rule based system to monitor the quality of higher education. This process of the research begins by documenting the daily activity of study program which consists of lecturer data, research data, service data, staff data, student data, and infrastructure data into a database. The data were evaluated by using rule based system  by adopting rules on quality standards of study program of National Accreditation Board for Higher Education as the knowledge base. Evaluation process was carried out by using the forward chaining methods by matching the existing data to the knowledge base to determine the quality status of each quality standard. While the reccomendation process was carried out by using the backward chaining methods by matching the results of quality status to the desired projection of quality status to determine the nearest target which can be achieved. The result of the research is system of quality assurance evaluation with rule based system that is capable of producing an output system in the form of internal evaluation report and recommendation system that can be used to monitor the quality of higher education.

  20. Development of multimedia computer-based training for VXI integrated fuel monitors

    International Nuclear Information System (INIS)

    Keeffe, R.; Ellacott, T.; Truong, Q.S.

    1999-01-01

    The Canadian Safeguards Support Program has developed the VXI Integrated Fuel Monitor (VFIM) which is based on the international VXI instrument bus standard. This equipment is a generic radiation monitor which can be used in an integrated mode where several detection systems can be connected to a common system where information is collected, displayed, and analyzed via a virtual control panel with the aid of computers, trackball and computer monitor. The equipment can also be used in an autonomous mode as a portable radiation monitor with a very low power consumption. The equipment has been described at previous international symposia. Integration of several monitoring systems (bundle counter, core discharge monitor, and yes/no monitor) has been carried out at Wolsong 2. Performance results from one of the monitoring systems which was installed at CANDU nuclear stations are discussed in a companion paper at this symposium. This paper describes the development of an effective multimedia computer-based training package for the primary users of the equipment; namely IAEA inspectors and technicians. (author)

  1. Active Job Monitoring in Pilots

    Science.gov (United States)

    Kuehn, Eileen; Fischer, Max; Giffels, Manuel; Jung, Christopher; Petzold, Andreas

    2015-12-01

    Recent developments in high energy physics (HEP) including multi-core jobs and multi-core pilots require data centres to gain a deep understanding of the system to monitor, design, and upgrade computing clusters. Networking is a critical component. Especially the increased usage of data federations, for example in diskless computing centres or as a fallback solution, relies on WAN connectivity and availability. The specific demands of different experiments and communities, but also the need for identification of misbehaving batch jobs, requires an active monitoring. Existing monitoring tools are not capable of measuring fine-grained information at batch job level. This complicates network-aware scheduling and optimisations. In addition, pilots add another layer of abstraction. They behave like batch systems themselves by managing and executing payloads of jobs internally. The number of real jobs being executed is unknown, as the original batch system has no access to internal information about the scheduling process inside the pilots. Therefore, the comparability of jobs and pilots for predicting run-time behaviour or network performance cannot be ensured. Hence, identifying the actual payload is important. At the GridKa Tier 1 centre a specific tool is in use that allows the monitoring of network traffic information at batch job level. This contribution presents the current monitoring approach and discusses recent efforts and importance to identify pilots and their substructures inside the batch system. It will also show how to determine monitoring data of specific jobs from identified pilots. Finally, the approach is evaluated.

  2. Monitoring solar-thermal systems: An outline of methods and procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, A. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.

    1994-04-01

    This manual discusses the technical issues associated with monitoring solar-thermal systems. It discusses some successful monitoring programs that have been implemented in the past. It gives the rationale for selecting a program of monitoring and gives guidelines for the design of new programs. In this report, solar thermal monitoring systems are classified into three levels. For each level, the report discusses the kinds of information obtained by monitoring, the effort needed to support the monitoring program, the hardware required, and the costs involved. Ultimately, all monitoring programs share one common requirement: the collection of accurate data that characterize some aspect or aspects of the system under study. This report addresses most of the issues involved with monitoring solar thermal systems. It does not address such topics as design fundamentals of thermal systems or the relative merits of the many different technologies employed for collection of solar energy.

  3. Best Management Practices Monitoring Guide for Stream Systems

    OpenAIRE

    Mesner, Nancy

    2011-01-01

    Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.

  4. International Workshop on Best Practices in Material Hold-Up Monitoring

    International Nuclear Information System (INIS)

    Pickett, Chris A; Coates, Cameron W.

    2008-01-01

    In the fall of 2006, the Oak Ridge National Laboratory (ORNL) hosted an INMM-sponsored International Workshop on Best Practices in Material Hold-Up Monitoring. This workshop represented the first time in over 20 years that the international community had gathered to discuss pertinent hold-up topics and needs. More than one hundred people attended the workshop. Their expertise in the field ranged from novice to expert, and they shared their experiences and expertise throughout the week of the workshop. Presenters discussed techniques that have been used worldwide to detect and characterize nuclear materials held up in processes and equipment and the policies used to report quantities detected. The primary goal of the workshop was to compile information on the best practices and lessons learned and to make this information available for sharing throughout the international community. This paper discusses the information that was produced from four separate working groups (each composed of workshop attendees). Each group was tasked to determine what it felt to be the best practices in the field today and what issues needed to be addressed to move the field forward in the 21st century

  5. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  6. The design of radiation monitor passageway system

    International Nuclear Information System (INIS)

    Chu Chengsheng

    2006-10-01

    The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)

  7. Current Monitoring System for ITER Like ICRH Antenna

    International Nuclear Information System (INIS)

    Argouarch, A.

    2006-01-01

    On TS antennas, the power transfer optimization from ICRH antenna to Plasma load is performed using feedback internal matching system. Experimental handling is required to mach the reactive impedance accordingly to the fluctuant plasma loading. As part of the development of the new ICRH prototype antenna, an additional measurement system based on Rogowski coils was developed to monitor the current distribution in antenna straps. The objective is to control module and phase of the antenna current straps with measurement provided by the coil system. Matching capacitors values, generators power and phase can also be controlled using the output of the devices, improving the real time matching control of the array. This paper details the new measurement layout, the Rogowski coil, and the whole system connected on each strap design for RF currents measurement between 40 MHz - 60 MHz for maximum amplitude of 1 kA. On the new ICRH prototype antenna, the measurement coils are coupled to the point where the strap currents are short circuited to the frame. The module and phase measurements are performed with the coils by direct magnetic induction in a vacuum and high temperature environment. Also, the Rogowski coils were characterized at low level power with vector network analyzer and the design adapted in order to obtain a controlled and reproducible gain in the desire bandwidth. The transconductive function is established with an experimental gain near -80 dB between primary circuit and inductive signal generated by the Rogowski coil. In a second step, the system with its associated electronic was qualified under high RF power. First results with high RF current (closed to 500 A at 57 MHz) match the desire Rogowski coil response. Compromises with electrical response at low power level and the coil under thermal/RF stresses were the most challenging part of the development. The overall response of the system and the current module/phase measurements are promising. A proper

  8. Development of distributed plant monitoring and diagnosis system at Monju

    International Nuclear Information System (INIS)

    Okusa, Kyoichi; Tamayama, Kiyoshi; Kitamura, Tomomi

    2003-01-01

    In a nuclear plant, it is required to detect an anomaly as early as possible and to inhibit adverse consequences. This requirement is especially important for a prototype Fast Breeder Reactor Monju. Therefore, a monitoring and diagnosis system is required to be developed for Monju plant equipments. In these days, such a monitoring and diagnosis system can be realized using Web technology with rationalized system resources due to the remarkable progress of computer network technology. Then, we developed a Web based platform for the monitoring and diagnosis system of Monju. Distributed architecture, standardization and highly flexible system structure have been taken account of in the development. This newly developed platform and prototype monitoring and diagnosis systems have been validated. Prototype monitoring and diagnosis systems on the platform acquire Monju plant data and display the data on client computers using Monju intranet with acceptable delay times. The prototype monitoring and diagnosis systems for Monju have been developed on the platform and the whole system has been validated. (author)

  9. Design Of Pump Monitoring Of Primary Cooling System

    International Nuclear Information System (INIS)

    Indrakoesoema, Koes; Sujarwono

    2000-01-01

    Monitoring of 3 primary cooling pumps done visually by operator on the spot. The operator must be check oil in a sight glass, oil leakage during pump operation and water leakage. If reaktor power increase about more than 3 MW, the radiation exposure also increase in the primary cell and that's way the operator can not check the pumps. To continuing monitor all pump without delay, one system has been added I.e Closed Circuit Television (CCTV). This system using 3 video camera to monitor 3 pumps and connected to one receiver video monitor by coaxial cable located in Main Control Room. The sequence monitoring can be done by sequential switcher

  10. Expert systems for real-time monitoring and fault diagnosis

    Science.gov (United States)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  11. Development of Compact Surveillance and Monitoring System 'COSMOS'

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  12. Development of Compact Surveillance and Monitoring System `COSMOS`

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Hironobu; Mukaiyama, Takehiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  13. Alpha-monitoring system

    International Nuclear Information System (INIS)

    Dincklage, R.D. von

    1982-01-01

    A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)

  14. Laboratory information management system: an example of international cooperation in Namibia

    Directory of Open Access Journals (Sweden)

    Patrizia Colangeli

    2012-09-01

    Full Text Available The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS to the Central Veterinary Laboratory (CVL in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia’s information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  15. On the use of multi-agent systems for the monitoring of industrial systems

    Science.gov (United States)

    Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil

    2016-03-01

    The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.

  16. The automatic radiation monitor distributed System SRM-256C

    International Nuclear Information System (INIS)

    Stetsenko, G.N.; Rastsvetalov, Y.N.; Yanovich, A.A.

    1996-01-01

    The Controlled and Supervised Areas (CSA) of UNK proton accelerator built in Protvino (IHEP, Russia), borrows the significant area (more than 15 sq.km). Submitted in work results of accounts show, that by major factors, influencing to a radioecological conditions in region at the expense of work UNK are: 1) the output of pulsing radiation on day-time surface; 2) the radionuclides receipts with drinking water; 3) the pollution of radioactive air from system of ventilation. At normal mode of UNK operation the equivalent dose rates on daytime surface of pulsing radiation will changes in limits from 0.5 mcSv/hours near overmines buildings up to 0.1 mcSv / hour on the CSA border. The average equivalent dose rates per year due to internal irradiation at use (intakes) of drinking water will not exceed 5 - 50 mcSv/years. The Maximum equivalent dose rates on day-time surface, caused by pollution of radioactive air does not exceed 0.01... 0.03 mcSv/hour in limits of CSA, and the average equivalent dose per year caused by internal irradiation does not exceed 0.05 mcSv/years. At emergency-free operation the maximum degree of the UNK influence in limits of CSA is estimated in terms of average equivalent dose per year at levels, not exceeding 0.05... 0.10 mSv/year. For maintenance of integral environmental monitoring of total external radiation levels in limits of CSA network of passive monitor stations will be developed

  17. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  18. Response of monitors of surface contamination to internal exposition control from 131I in the 'nuclear medicine services'

    International Nuclear Information System (INIS)

    Puerta, Nancy; Rojo, Ana M.; Villella, Adrian; Gossio, Sebastian; Parada, Ines Gomez; Acosta, Norma; Arenas, German

    2013-01-01

    The IAEA, in its publication RS-G-1.2, proposes individual control of workers occupationally exposed with risk of internal exposure when the potential exposure provided by incorporation leads to a value of annual committed effective dose equal to or greater than 1 mSv. Because the radionuclide 131 I is the most important to control internal exposure in Nuclear Medicine Services, it is evaluated if the surface contamination monitors, commonly used in nuclear medicine centers of Argentina, would implement individual control of internal exposure to 131 I. Selected detectors were calibrated with a dummy neck and thyroid with calibrated sources of 131 I and 133 Ba reference. For each detector is was estimated the detection efficiency for 131 I and its detection limit. Each instrument was evaluated for the lowest effective dose possible to detect compromised by individual routine monitoring with different measurement intervals . We analyzed the response of each team for determining conditions that may be effective for the control of internal exposure of 131 I. Finally , we conclude that the daily individual monitoring surface contamination detectors available in the Nuclear Medicine Services is feasible to implement and ensures detection of significant additions of 131 I

  19. Automated wireless monitoring system for cable tension using smart sensors

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang

    2013-04-01

    Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.

  20. Toward an integrated system concept for monitoring and evaluation of safety culture

    International Nuclear Information System (INIS)

    Makino, Maomi; Sakaue, Takeharu

    2004-01-01

    The concept of ''nuclear safety culture'' has been advocated and has been much discussed internationally by INSAG (The International Nuclear Safety Advisory Group) under IAEA (the International Atomic Energy Agency) and other institutions since Chernobyl accident. On the safety front, Japan had maintained an excellent track record in nuclear power operations throughout the 1990s. However, there have been a series of new type of problems strongly implying degradation of safety culture, e.g., Monju accident, fire and explosion accident at an Asphalt Solidification Process Facility at Tokai, falsification of annealing data at nuclear power plants (NPP), another data falsification for transport cask of spent fuel and JCO criticality accident. Then the TEPCO (Tokyo Electric Power Company) issue was revealed in 2002. Triggered by this issue, the Nuclear and Industrial Safety Agency (NISA) has been implementing a variety of improvements, one of which was the establishment of a study group in 2003, which invited experts from other fields as well as from nuclear-related industries, to study on how to implement safety culture sufficiently and possible recommendations. Subjects such as the followings piled in the study report will indicate leading keys in case it is going to realize such efforts: ''Foundation of safety culture is a quality management'' and ''Realistic and scientific technique is necessary for the evaluation of safety culture''. In order to respond to these requests, JNES have been advancing the development toward an Integrated System Concept for Monitoring and Evaluation of Safety Culture. This paper describes the outline of the study results reported by the study group and then introduces one of subsystems, SCEST, structuring the integrated system concept for Monitoring and Evaluation of Safety Culture. (author)

  1. Design of smart neonatal health monitoring system using SMCC.

    Science.gov (United States)

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  2. Diagnostic and monitoring systems in nuclear power plants

    International Nuclear Information System (INIS)

    Wehling, H.J.; Jax, P.; Streicher, V.

    1987-01-01

    Monitoring systems are important for the availability of nuclear power plants. A survey is given about such systems designed and constructed by the Kraftwerk Union AG Erlangen (Federal Republic of Germany) in order to assure the mechanical integrity of reactor cooling systems. Three monitoring systems based on microprocessors are presented: KUES (acoustic detection of loose parts), SUES (vibration), and FAMOS (fatigue)

  3. 13th Workshop on Radiation Monitoring for the International Space Station - Final Program

    International Nuclear Information System (INIS)

    2008-01-01

    The Workshop on Radiation Monitoring for the International Space Station (WRMISS) has been held annually since 1996. The major purpose of WRMISS is to provide a forum for discussion of technical issues concerning radiation dosimetry aboard the International Space Station. This includes discussion of new results, improved instrumentation, detector calibration, and radiation environment and transport models. The goal of WRMISS is to enhance international efforts to provide the best information on the space radiation environment in low-Earth orbit and on the exposure of astronauts and cosmonauts in order to optimize the radiation safety of the ISS crew. During the 13 th Annual WRMISS, held in the Institute of Nuclear Physics (Krakow, Poland) on 8-10 September 2008, participants presented 47 lectures

  4. 1st International Conference on Machine Learning for Cyber Physical Systems and Industry 4.0

    CERN Document Server

    Beyerer, Jürgen

    2016-01-01

    The work presents new approaches to Machine Learning for Cyber Physical Systems, experiences and visions. It contains some selected papers from the international Conference ML4CPS – Machine Learning for Cyber Physical Systems, which was held in Lemgo, October 1-2, 2015. Cyber Physical Systems are characterized by their ability to adapt and to learn: They analyze their environment and, based on observations, they learn patterns, correlations and predictive models. Typical applications are condition monitoring, predictive maintenance, image processing and diagnosis. Machine Learning is the key technology for these developments.

  5. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  6. Evaluation of the HACCP system in a university canteen: microbiological monitoring and internal auditing as verification tools.

    Science.gov (United States)

    Osimani, Andrea; Aquilanti, Lucia; Tavoletti, Stefano; Clementi, Francesca

    2013-04-17

    Food safety is essential in mass catering. In Europe, Regulation (EC) No. 852/2004 requires food business operators to put in place, implement and maintain permanent procedures based on Hazard Analysis and Critical Control Point (HACCP) principles. Each HACCP plan is specifically implemented for the processing plant and processing methods and requires a systematic collection of data on the incidence, elimination, prevention, and reduction of risks. In this five-year-study, the effectiveness of the HACCP plan of a University canteen was verified through periodic internal auditing and microbiological monitoring of meals, small equipment, cooking tools, working surfaces, as well as hands and white coats of the canteen staff. The data obtained revealed no safety risks for the consumers, since Escherichia coli, Salmonella spp. and Listeria monocytogenes were never detected; however, a quite discontinuous microbiological quality of meals was revealed. The fluctuations in the microbial loads of mesophilic aerobes, coliforms, Staphylococcus aureus, Bacillus cereus, and sulphite-reducing clostridia were mainly ascribed to inadequate handling or processing procedures, thus suggesting the need for an enhancement of staff training activities and for a reorganization of tasks. Due to the wide variety of the fields covered by internal auditing, the full conformance to all the requirements was never achieved, though high scores, determined by assigning one point to each answer which matched with the requirements, were achieved in all the years.

  7. Evaluation of the HACCP System in a University Canteen: Microbiological Monitoring and Internal Auditing as Verification Tools

    Science.gov (United States)

    Osimani, Andrea; Aquilanti, Lucia; Tavoletti, Stefano; Clementi, Francesca

    2013-01-01

    Food safety is essential in mass catering. In Europe, Regulation (EC) No. 852/2004 requires food business operators to put in place, implement and maintain permanent procedures based on Hazard Analysis and Critical Control Point (HACCP) principles. Each HACCP plan is specifically implemented for the processing plant and processing methods and requires a systematic collection of data on the incidence, elimination, prevention, and reduction of risks. In this five-year-study, the effectiveness of the HACCP plan of a University canteen was verified through periodic internal auditing and microbiological monitoring of meals, small equipment, cooking tools, working surfaces, as well as hands and white coats of the canteen staff. The data obtained revealed no safety risks for the consumers, since Escherichia coli, Salmonella spp. and Listeria monocytogenes were never detected; however, a quite discontinuous microbiological quality of meals was revealed. The fluctuations in the microbial loads of mesophilic aerobes, coliforms, Staphylococcus aureus, Bacillus cereus, and sulphite-reducing clostridia were mainly ascribed to inadequate handling or processing procedures, thus suggesting the need for an enhancement of staff training activities and for a reorganization of tasks. Due to the wide variety of the fields covered by internal auditing, the full conformance to all the requirements was never achieved, though high scores, determined by assigning one point to each answer which matched with the requirements, were achieved in all the years. PMID:23594937

  8. Methods, apparatus, and systems for monitoring transmission systems

    Science.gov (United States)

    Polk, Robert E [Idaho Falls, ID; Svoboda, John M [Idaho Falls, ID; West, Phillip B [Idaho Falls, ID; Heath, Gail L [Iona, ID; Scott, Clark L [Idaho Falls, ID

    2010-08-31

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  9. Assessment of necessary regularity of internal irradiation monitoring on the basis of direct and indirect methods of dosimetry

    International Nuclear Information System (INIS)

    Malykhin, V.M.; Ivanova, N.I.

    1981-01-01

    It is shown that when assessing the necessary periodicity of internal irradiation monitoring, it is required to take account of the nature (rhythm) of radionuclide intake to the organism during the monitoring period, the effective period of radionuclide biological half-life, its activity in the organism, sensitivity of the technique applied and the labour-consumig character of the monitoring method [ru

  10. Transparencies used in describing the CTBT verification regime and its four monitoring technologies

    International Nuclear Information System (INIS)

    Basham, P.

    1999-01-01

    This presentation includes description of the CTBT verification regime and its four monitoring technologies, (namely, seismic monitoring, hydro acoustic monitoring, infrasound monitoring and radionuclides monitoring) CTBT global verification system, sequence of steps needed for installing an international monitoring system station which includes: site survey, site preparation and construction, equipment procurement and installation, final tests and certification

  11. A monitor system for end cap shower counter of Beijing spectrometer

    International Nuclear Information System (INIS)

    Wang Man; Xia Xiaomi; Lai Yuanfen; Cheng Baosen; Li Jin

    1993-01-01

    To keep a large-scale detector system running in a correct condition and to obtain some correct parameters, it is necessary to have a monitor system monitoring the detector system operation in real time. In the paper, the structure of End Cap Shower Counter monitor system of Beijing Spectrometer is described. Some properties of this monitor system and the real-time monitoring results during operation of Beijing Spectrometer are given

  12. Implementation of medical monitor system based on networks

    Science.gov (United States)

    Yu, Hui; Cao, Yuzhen; Zhang, Lixin; Ding, Mingshi

    2006-11-01

    In this paper, the development trend of medical monitor system is analyzed and portable trend and network function become more and more popular among all kinds of medical monitor devices. The architecture of medical network monitor system solution is provided and design and implementation details of medical monitor terminal, monitor center software, distributed medical database and two kind of medical information terminal are especially discussed. Rabbit3000 system is used in medical monitor terminal to implement security administration of data transfer on network, human-machine interface, power management and DSP interface while DSP chip TMS5402 is used in signal analysis and data compression. Distributed medical database is designed for hospital center according to DICOM information model and HL7 standard. Pocket medical information terminal based on ARM9 embedded platform is also developed to interactive with center database on networks. Two kernels based on WINCE are customized and corresponding terminal software are developed for nurse's routine care and doctor's auxiliary diagnosis. Now invention patent of the monitor terminal is approved and manufacture and clinic test plans are scheduled. Applications for invention patent are also arranged for two medical information terminals.

  13. Monobuoy monitoring system - project, installation and preliminary results; Sistema de monitoracao de monoboias maritimas - desenvolvimento, instalacao e analise preliminar de resultados

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Daniel L; Machado Filho, Remo Z [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas; Medeiros, Junior, Adory J [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    A monobuoy monitoring system was developed and installed on 2004 in two oil terminals of TRANSPETRO. The main purpose of this system is to assure that monobuoys will be assisted during offloading operations, which will reduce the risk of accidents and detect immediately damages on mooring lines and equipment. The system comprises a Control Module on terminal site and a Remote Monitoring Unit, installed on each monobuoy. The link between modules is provided by an UHF radio-modem. The parameters acquired are pitch, roll, heave, geographic position, internal variables, and, if available, pressure and temperature of lines, traction on mooring system, etc. Positioning information is processed by the PETRONAV Positioning System. The whole process is registered and monitored on terminal with graphical interface. This article describes the development and installation of the system and the preliminary analysis of data produced since the system was installed. (author)

  14. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  15. Remote monitoring system workshop and technical cooperation

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W.

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person

  16. Research and Implementation of Distributed Database HBase Monitoring System

    Directory of Open Access Journals (Sweden)

    Guo Lisi

    2017-01-01

    Full Text Available With the arrival of large data age, distributed database HBase becomes an important tool for storing data in massive data age. The normal operation of HBase database is an important guarantee to ensure the security of data storage. Therefore designing a reasonable HBase monitoring system is of great significance in practice. In this article, we introduce the solution, which contains the performance monitoring and fault alarm function module, to meet a certain operator’s demand of HBase monitoring database in their actual production projects. We designed a monitoring system which consists of a flexible and extensible monitoring agent, a monitoring server based on SSM architecture, and a concise monitoring display layer. Moreover, in order to deal with the problem that pages renders too slow in the actual operation process, we present a solution: reducing the SQL query. It has been proved that reducing SQL query can effectively improve system performance and user experience. The system work well in monitoring the status of HBase database, flexibly extending the monitoring index, and issuing a warning when a fault occurs, so that it is able to improve the working efficiency of the administrator, and ensure the smooth operation of the project.

  17. PC based vibration monitoring system

    International Nuclear Information System (INIS)

    Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.

    2004-01-01

    Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)

  18. Development of an enhanced loose parts monitoring system (LPMS)

    International Nuclear Information System (INIS)

    Choi, Y. C.; Park, J. H.; Yoon, D. B.; Choi, K. S.; Sohn, C. H.

    2006-01-01

    LPMS (loose parts monitoring system) is one of the most important structural integrity monitoring systems. It is operated for a early detection of the impacts by loosened or detached metallic, objects on the primary pressure boundary in a nuclear power plant. The impacted parts might cause flow blockage in the fuel channel, prevent the control rod from moving properly, damage the pump impeller, and give rise to cracks on the steam generator tube sheet, etc. In Korea, The LPMS is currently operating in all of the nuclear power plants as a subsystem in the NIMS (NSSS Integrity Monitoring System), However the performances are being deteriorated in both the hardware and software since it was designed in 1980's. In particular the system is not capable of promptly responding to the continuously triggered impacts in a short period failing to monitor the real loose parts. Also the diagnostic tools to estimate the location and the mass or energy of the impact source have not been reflected. Therefore, a new loose parts monitoring system has been developed to improve the capabilities of the current one and ultimately to replace it. An enhanced Loose Parts Monitoring System(LPMS) has been developed by KAERI(Korea Atomic Energy Research Inst.), not only to improve the performance of an on-line signal processing for a monitoring system but also to enhance the evaluation technique of the true impact signals by loose parts. This new system has taken into account the state-of-the-art technology to cover the problems with the conventional system. (authors)

  19. Environmental monitoring systems: a new type of mobile laboratory

    International Nuclear Information System (INIS)

    Bruecher, L.; Langmueller, G.; Tuerschmann, G.

    1999-01-01

    Nuclear facilities are obligated to monitor the environmental radiation in their vicinity, which is often fulfilled by monitoring cars, combined with fixed monitoring stations. The MOLAR Mobile Laboratory for Environmental Radiation Monitoring as described here is being used under normal and accident conditions as a spot check monitoring system or to perform continuous measurements along a driving track. The mobile laboratories are continuously connected with the control centre's CRCS Central Radiological Computer System, where the RIS Radiological Information System provides corresponding evaluation functions. The mobile labs contain measuring and controlling units like γ-dose rate monitors, γ-spectrometer with a HpGe High Purity Germanium detector, a lead shielded measuring cell and MCA Multi-Channel Analyser, portable β-contamination monitor, α/β/γ multipurpose quick measuring unit, aerosol and iodine sampling units. The collected samples are safely stored for the transport to the environmental laboratory for being analysed later. The geographical location of the moving car is continuously determined by the satellite based GPS Global Positioning System and transferred in the on-board rack mounted computer system for being stored and locally displayed. Real-time data transmission via radio and mobile phone is continuously performed to supply the RIS Radiological Information System in the control centre via radio and mobile phone. The latter also serves for voice communication. Currently three MOLAR systems can be operated parallel and independent from the control centre. The system is ready to be extended to more mobile labs. This combination of mobile monitoring, sample analysis and radiological assessment of environmental data in combination with process occurrences has turned out to be a powerful instrument for emergency preparedness and environmental supervising. (orig.) [de

  20. Design of multi-channel analyzer's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Yang Tao; Wei Yixiang

    2007-01-01

    A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)

  1. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  2. Study on intermediate frequency power supply automatic monitor system

    International Nuclear Information System (INIS)

    Wang Yuntong; Xu Bin

    2007-06-01

    A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)

  3. Individual monitoring of internal exposure of 131I of workers from the nuclear medicine service FUESMEN, Argentina

    International Nuclear Information System (INIS)

    Arenas, G.; Acosta, N.; Venier, V.; Bedoya Toboo, C.

    2013-01-01

    It is presented the FUESMEN experience in routine monitoring of thyroid internal doses due to inhalation of 131 I in workers of the Nuclear Medicine Service in normal operation or accidental exposure. It is used a surface contamination monitor, type Geiger Mueller, calibrated with a acrylic phantom based on specifications of the simulator of thyroid of ICRU 48 with 131 I reference activity. Through the obtained measurements is achieved to validate the use of Portable Monitor to carry out preliminary exploration on the monitoring scenarios of incidental situations

  4. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  5. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  6. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  7. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  8. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  9. Requirements for internal contamination monitoring units; Anforderungen an Inkorporationsmessstellen

    Energy Technology Data Exchange (ETDEWEB)

    Werner, E. [GSF, Inst. fuer Biophysikalische Strahlenforschung, Frankfurt am Main (Germany); Beyer, D. [Forschungszentrum Juelich, Abt. ASS (Germany); Doerfel, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany); Erlenbach, H. [Zentralstelle fuer Sicherheitstechnik NRW, Duesseldorf (Germany); Fischbach, G. [Siemens Brennelementewerk, Hanau (Germany); Henrichs, K. [Siemens AG, Muenchen (Germany); Keller, K.D. [Radiologische Universitaetsklinik, Tuebingen (Germany); Koenig, K. [Bundesamt fuer Strahlenschutz, ISH, Neuherberg (Germany); Riedel, W. [Freie Univ. Berlin, Klinikum Steglitz (Germany); Scheler, R. [Bundesamt fuer Strahlenschutz, FB Strahlenschutz, Berlin (Germany); Schieferdecker, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany)

    1994-12-31

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [Deutsch] Zur Ermittlung der Koerperdosen nach Paragraph 63 StrlSchV sind fuer die gemaess Abs. 6 von der zustaendigen Behoerde zu bestimmenden Messstellen in einer Richtlinie einheitliche Anforderungen festzulegen. Diese beziehen sich auf deren Ausstattung, die Durchfuehrung der Messungen, Auswertungen und Qualitaetskontrollen sowie die Aufzeichnung und Uebermittlung der Ergebnisse. Die Aufgaben der Messstellen umfassen die Messungen der Radioaktivitaet im Koerper bzw. in Koerperausscheidungen, die Ermittlung der Zufuhr an Radionukliden sowie der daraus resultierenden Koerperdosis und die Weiterleitung der Ergebnisse an den Auftraggeber, an das zentrale Dosisregister und in bestimmten Faellen an die Behoerde. Zu den von einer Messstelle zu erfuellenden Anforderungen gehoeren eine ausreichende Messeffektivitaet, die Durchfuehrung von Eigenkontrollen

  10. Internal testing of pipe systems with IRIS inspection system

    International Nuclear Information System (INIS)

    1986-01-01

    The internal piping inspection system IRIS allows inside testing of pipes with an internal diameter of NW 70 as a minimum, and of any horizontal or vertical layout of the piping system. Visual testing is done by means of an integrated CCD video system with high resolution power. Technical data are given and examples of applications, in the German and English language. (DG) [de

  11. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  12. Wearable Eating Habit Sensing System Using Internal Body Sound

    Science.gov (United States)

    Shuzo, Masaki; Komori, Shintaro; Takashima, Tomoko; Lopez, Guillaume; Tatsuta, Seiji; Yanagimoto, Shintaro; Warisawa, Shin'ichi; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of eating habits could be useful in preventing lifestyle diseases such as metabolic syndrome. Conventional methods consist of self-reporting and calculating mastication frequency based on the myoelectric potential of the masseter muscle. Both these methods are significant burdens for the user. We developed a non-invasive, wearable sensing system that can record eating habits over a long period of time in daily life. Our sensing system is composed of two bone conduction microphones placed in the ears that send internal body sound data to a portable IC recorder. Applying frequency spectrum analysis on the collected sound data, we could not only count the number of mastications during eating, but also accurately differentiate between eating, drinking, and speaking activities. This information can be used to evaluate the regularity of meals. Moreover, we were able to analyze sound features to classify the types of foods eaten by food texture.

  13. 296-B-5 Stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1995-02-01

    The B Plant Administration Manual requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with Stack 296-B-5 at B Plant. The sampling and monitoring system associated with stack 296-B-5 is functional and performing satisfactorily. This document is an annual assessment report of the systems associated with the 296-B-5 stack

  14. EDGAR, a new plant radiation monitoring system

    International Nuclear Information System (INIS)

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  15. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  16. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    Energy Technology Data Exchange (ETDEWEB)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P

    2006-09-15

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO{sub 2} into U-metal. For demonstration of this process, {alpha}-{gamma} type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for {gamma}-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  17. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    International Nuclear Information System (INIS)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-09-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for γ-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration

  18. Monitoring and Prognosis System Based on the ICF for People with Traumatic Brain Injury

    Directory of Open Access Journals (Sweden)

    Laia Subirats

    2015-08-01

    Full Text Available The objective of this research is to provide a standardized platform to monitor and predict indicators of people with traumatic brain injury using the International Classification of Functioning, Disability and Health, and analyze its potential benefits for people with disabilities, health centers and administrations. We developed a platform that allows automatic standardization and automatic graphical representations of indicators of the status of individuals and populations. We used data from 730 people with acquired brain injury performing periodic comprehensive evaluations in the years 2006–2013. Health professionals noted that the use of color-coded graphical representation is useful for quickly diagnose failures, limitations or restrictions in rehabilitation. The prognosis system achieves 41% of accuracy and sensitivity in the prediction of emotional functions, and 48% of accuracy and sensitivity in the prediction of executive functions. This monitoring and prognosis system has the potential to: (1 save costs and time, (2 provide more information to make decisions, (3 promote interoperability, (4 facilitate joint decision-making, and (5 improve policies of socioeconomic evaluation of the burden of disease. Professionals found the monitoring system useful because it generates a more comprehensive understanding of health oriented to the profile of the patients, instead of their diseases and injuries.

  19. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  20. Quaternion Based Thermal Condition Monitoring System

    Science.gov (United States)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.