WorldWideScience

Sample records for internal teat sealant

  1. Effectiveness of Dry Cow Therapy Comprising Antibiotic Treatment, Internal Teat Sealant, and α-Tocopherol Against New Intramammary Infections in Cows

    Directory of Open Access Journals (Sweden)

    Cengiz Mehmet

    2015-04-01

    Full Text Available The aim of this study was to evaluate the preventive effectiveness of dry cow therapy based on antibiotic, internal teat sealant, and α-tocopherol administered separately or in various combinations at drying-off The study was performed on 322 uninfected quarters of 95 cows originating from three dairy herds. The new intramammary infection rates after calving were measured to evaluate the effectiveness. The quarters were divided into six groups differing in treatment, namely: control group (group C, n = 40 and five treatment groups. Treatment groups were arranged as follows: group A (antibiotic alone, n = 81, group AS (antibiotic + sealant, n = 40, group AST (antibiotic + sealant + α-tocopherol, n = 40, group T (α-tocopherol alone, n = 40, group S (sealant alone, n = 81. New infection rate amounted to 47.5% in group C. The treatment in group AST significantly prevented from the occurrence of new intramammary infections (12.5%, P 0.05, although the use of the sealant alone (group S decreased the risk of new infection (24.7%, P 0.05. Increased α-tocopherol level (P < 0.05 was detected after calving in the quarters from cows that received α-tocopherol injections. In conclusion, the combination of antibiotic, internal teat sealant, and α-tocopherol used in dry cow therapy showed a significantly better preventive effect against new intramammary infections, than the therapeutics administered separately.

  2. Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.

    Science.gov (United States)

    Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S

    2007-01-01

    This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.

  3. A comparison of the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts after calving in cows also given internal teat sealants.

    Science.gov (United States)

    Whitfield, L K; Laven, R A

    2018-01-01

    To compare, in cows treated with an internal teat sealant, the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts (SCC) after calving. Cows from a spring-calving, pasture-based dairy farm in the Manawatu-Whanganui region of New Zealand were randomly allocated to receive either a short-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=291) or a long-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=288) at the end of lactation. Cows were managed on-farm with routine husbandry procedures through the dry period and following calving. A multivariable logistic regression model was used to determine the association between length of action of dry-cow therapy and the proportion of cows with a SCC >150,000 cells/mL at the first herd test after calving. Age of cow, mean SCC for the preceding season and interval from calving to the first post-calving herd test were all associated with the proportion of cows with an individual SCC >150,000 cells/mL at the first herd test (pcow therapy was not associated with decreased odds of cows having a SCC >150,000 cells/mL at the first herd test compared with treatment with long-acting dry-cow therapy (OR=0.724; 95% CI=0.40-1.30). In this herd, which routinely used internal teat sealants, the use of short-acting cloxacillin-based dry-cow therapy did not result in an increased proportion of cows with elevated SSC post-calving. This was a single farm, single year study but indicates that in this herd, changing from a long-acting to a short-acting antimicrobial may have no impact on the prevalence of subclinical mastitis.

  4. Effect of dry period length on the effect of an intramammary teat sealant on the risk of mastitis in cattle treated with antibiotics at drying off.

    Science.gov (United States)

    Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E

    2014-07-01

    The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole

  5. An observational cohort study on persistency of internal teat sealant residues in milk after calving in dairy cows.

    Science.gov (United States)

    Kabera, Fidèle; Dufour, Simon; Keefe, Greg; Roy, Jean-Philippe

    2018-04-04

    Our objectives were to evaluate the prevalence of quarters with an observable internal teat sealant (ITS) plug at first milking following calving and investigate persistency of ITS residues in milk after calving. An observational cohort study was carried out on 557 quarters of 156 cows treated with ITS in 6 farms in Quebec, Canada. The presence of an ITS plug at first milking and ITS residues in milk at each milking were observed by producers. The effects of various factors on the odds of observing an ITS plug and persistency of ITS residues in milk were studied using generalized logistic mixed and generalized negative binomial mixed models, respectively. Milk samples were taken on the day before dry-off and on 2 occasions after calving for bacterial identification to detect intramammary infection (IMI) using bacteriological culture followed by MALDI-TOF identification. The association between the absence of an ITS plug and the presence of new IMI was assessed using a mixed logistic regression model. Internal teat sealant plugs after calving were more often observed in rear quarters and in quarters receiving ITS alone at drying-off versus antimicrobial and ITS. We observed an average (standard deviation) persistency of 4.0 d (2.3 d). When an ITS plug was still present at first milking (83% of quarters), the elimination of ITS residues in milk after calving was significantly longer (4.5 d, on average) compared with 1.2 d when an ITS plug was absent. In cows with an ITS plug at calving, we observed a higher number of days of excretion in older cows. When a plug could not be observed, rear quarters, older cows, and cows with a long dry period duration excreted ITS residues for a significantly longer period. The lack of a significant association between the absence of a plug and the odds of new IMI at calving suggests that despite the loss of the plug, cows were still protected against new IMI. Although we were able to highlight some statistically significant risk

  6. Comparison of cephalonium alone and in combination with an internal teat sealant for dry cow therapy in seasonally calving dairy cows.

    Science.gov (United States)

    Bates, A J; Chambers, G; Laven, R A

    2016-03-01

    To assess the effect of combining an internal teat sealant (ITS) and a long-acting cephalonium-based dry cow therapy (DCT) on the prevalence of cows with a somatic cell count (SCC) >150,000 cells/mL 60-80 days after calving, and the incidence of clinical mastitis diagnosed by farm staff in the first 100 days after calving. Cows from a spring-calving, pasture-based, dairy farm in the South Canterbury region of New Zealand were randomly allocated to receive cephalonium DCT (n=289) or cephalonium and internal teat sealant (n=304) at the end of lactation. Cows were inspected twice daily by farm staff during the dry period and following calving for signs of mastitis. Individual SCC were determined from herd tests conducted in the previous lactation and following calving. Logistic regression models were used to determine relationships with the prevalence of cows with a SCC >150,000 cells/mL after calving, and survival analysis was used to model time to the first case of clinical mastitis following calving at the cow and quarter level. The OR for a cow with a SCC >150,000 cells/mL after calving, including age and individual SCC in the preceding lactation in the model, was 0.53 (95% CI=0.32-0.89) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.017). At the cow level, including age and preceding SCC in the model, the hazard ratio for diagnosis of clinical mastitis by farm staff in the first 100 days of lactation was 0.60 (95% CI=0.39-0.98) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.04). At the quarter level, the hazard ratio for diagnosis of clinical mastitis, with age included in the model, was 0.41 (95% CI=0.23-0.74) for the combination therapy compared to cephalonium alone (pmastitis diagnosed by farm staff in the 100 days after calving, and the prevalence of cows with a SCC >150,000 cells/mL 60-80 days after calving. This study adds to the evidence that the prevention of intra mammary

  7. Efficacy of an internal teat seal associated with a dry cow intramammary antibiotic for prevention of intramammary infections in dairy cows during the dry and early lactation periods

    Directory of Open Access Journals (Sweden)

    Lívio R. Molina

    Full Text Available ABSTRACT: The present study aimed to evaluate the use of an internal dry period teat seal containing bismuth subnitrate (Teatseal®, Zoetis®, Florham Park, Nova Jersey, USA associated with a long-acting cloxacilin preparation (Orbenin® Extra dry cow, Zoetis®, Florham Park, Nova Jersey, USA, in preventing new infections during the dry-off and early postpartum period. A total of 150 Holstein cows (average production of 9,000 kg of milk per lactation, with four functional udder quarters without clinical mastitis was included in the study. All animals were dried-off 60 days before the expected calving date. Two teats positioned diagonal-contralaterally received only dry cow antibiotic, control group C (n=300 and the other two teats, treatment group T (n=300 received dry cow antibiotic and infusion with an internal teat seal. Data from SCC variable were transformed by log base-10 transformation. Duncan’s test was used accepting 5% as the level of statistical significance. The occurrence of intramammary infection (IMI and chronicity rate, and frequency of microorganisms isolated at drying and immediately postpartum in teats of group C and group T were evaluated using a non-parametric Chi-square Test, accepting 10% as the statistical significance level. There was a decrease in the occurrence of new infections in the early postpartum in cows which the sealant was used (C=19.6%, T=11.4%. In the postpartum period, Gram-negative bacteria were isolated from 16 teats in C and seven in T. The greatest reduction was observed for Escherichia coli (8 vs 1 in group T. There was no effect using the internal sealant on the frequency of isolation of environmental Streptococus. The use of sealant reduced the prevalence of subclinical mastitis cows between drying-off and the early postpartum period (C=51% versus T=42% and resulted in a lower somatic cell count (SCC in the treatment group when compared with the control group (T=1,073x103, C=1,793x103. The use of

  8. Estimating teat canal cross-sectional area to determine the effects of teat-end and mouthpiece chamber vacuum on teat congestion.

    Science.gov (United States)

    Penry, J F; Upton, J; Mein, G A; Rasmussen, M D; Ohnstad, I; Thompson, P D; Reinemann, D J

    2017-01-01

    The primary objective of this experiment was to assess the effect of mouthpiece chamber vacuum on teat-end congestion. The secondary objective was to assess the interactive effects of mouthpiece chamber vacuum with teat-end vacuum and pulsation setting on teat-end congestion. The influence of system vacuum, pulsation settings, mouthpiece chamber vacuum, and teat-end vacuum on teat-end congestion were tested in a 2×2 factorial design. The low-risk conditions for teat-end congestion (TEL) were 40 kPa system vacuum (Vs) and 400-ms pulsation b-phase. The high-risk conditions for teat-end congestion (TEH) were 49 kPa Vs and 700-ms b-phase. The low-risk condition for teat-barrel congestion (TBL) was created by venting the liner mouthpiece chamber to atmosphere. In the high-risk condition for teat-barrel congestion (TBH) the mouthpiece chamber was connected to short milk tube vacuum. Eight cows (32 quarters) were used in the experiment conducted during 0400 h milkings. All cows received all treatments over the entire experimental period. Teatcups were removed after 150 s for all treatments to standardize the exposure period. Calculated teat canal cross-sectional area (CA) was used to assess congestion of teat tissue. The main effect of the teat-end treatment was a reduction in CA of 9.9% between TEL and TEH conditions, for both levels of teat-barrel congestion risk. The main effect of the teat-barrel treatment was remarkably similar, with a decrease of 9.7% in CA between TBL and TBH conditions for both levels of teat-end congestion risk. No interaction between treatments was detected, hence the main effects are additive. The most aggressive of the 4 treatment combinations (TEH plus TBH) had a CA estimate 20% smaller than for the most gentle treatment combination (TEL plus TBL). The conditions designed to impair circulation in the teat barrel also had a deleterious effect on circulation at the teat end. This experiment highlights the importance of elevated mouthpiece

  9. Teat condition in dairy cows

    NARCIS (Netherlands)

    Neijenhuis, Francesca

    2004-01-01

    The dairy cow's teat is the first line of defence against mastitis pathogens. The milking process may affect the teat's condition, increasing the risk of mastitis. It is well-proven that teat-ends with severe erosions or broken skin will have an increased risk of mastitis. However, more common

  10. Teat Condition in Dairy Cows

    NARCIS (Netherlands)

    Neijenhuis, F.

    2004-01-01

    The dairy cow's teat is the first line of defence against mastitis pathogens. The milking process may affect the teat's condition, increasing the risk of mastitis. It is well-proven that teat-ends with severe erosions or broken skin will have an increased risk of mastitis. However, more common

  11. An observational study investigating the association of ultrasonographically assessed machine milking-induced changes in teat condition and teat-end shape in dairy cows.

    Science.gov (United States)

    Wieland, M; Virkler, P D; Borkowski, A H; Älveby, N; Wood, P; Nydam, D V

    2018-06-21

    Mechanical forces during machine milking induce changes in teat condition which can be differentiated into short-term and long-term changes. Machine milking-induced short-term changes in teat condition (STC) are defined as tissue responses to a single milking and have been associated with the risk of new intramammary infection. Albeit, their association with teat characteristics, such as teat-end shape, has not been investigated by rigorous methods. The primary objective was to determine the association of STC, as measured by ultrasonography, with teat-end shape. The second objective was to describe possible differences in the recovery time of teat tissue after machine milking among teats with different teat-end shapes. Holstein cows (n=128) were enrolled in an observational study, housed in free-stall pens with sand bedding and milked three times a day. Ultrasonography of the left front and right hind teat was performed after teat preparation before milking (t-1), immediately after milking (t 0) and 1, 3, 5 and 7 h after milking (t 1, t 3, t 5, t 7). The teat tissue parameters measured from ultrasound scans were teat canal length, teat-end diameter, teat-end diameter at the midpoint between the distal and proximal end of the teat canal, teat wall thickness, and teat cistern width. Teat-end shape was assessed visually and classified into three categories: pointed, flat and round. Multivariable linear regression analyses showed differences in the relative change of teat tissue parameters (compared with t-1) at t 0 among teats with different teat-end shapes, with most parameters showing the largest change for round teats. The premilking values were reached (recovery time) after 7 h in teats with a pointed teat-end shape, whereas recovery time was greater than 7 h in teats with flat and round teat-end shapes. Under the same liner and milking machine conditions, teats with a round teat-end shape had the most severe short-term changes. The results of this observational

  12. Anatomical characteristics of teats and premilking bacterial counts of teat skin swabs of primiparous cows exposed to different types of bedding.

    Science.gov (United States)

    Guarín, J F; Baumberger, C; Ruegg, P L

    2017-02-01

    Bacterial populations of teat skin are associated with risk of intramammary infection and may be influenced by anatomical characteristics of teats. The objective of this study was to evaluate associations of selected anatomical characteristics of teats with bacterial counts of teat skin of cows exposed to different types of bedding. Primarily primiparous Holstein cows (n = 128) were randomly allocated to 4 pens within a single barn. Each pen contained 1 type of bedding [new sand (NES), recycled sand (RS), deep-bedded manure solids (DBMS), and shallow-bedded manure solids over foam core mattresses (SBMS)]. During a single farm visit udders (n = 112) were scored for hygiene and 1 front (n = 112) and 1 rear teat (n = 111) of each enrolled cow were scored for hyperkeratosis (HK). Teat length, teat barrel diameter, and teat apex diameter were measured and teat skin swabs were systematically collected for microbiological analysis. Linear type evaluation data for udders of each cow were retrieved for each cow. Teat position (front or rear) was associated with occurrence of clinical mastitis during the 12 mo before the farm visit and more cases occurred in front quarters. The proportion of udders that were classified as clean (score 1 or 2) was 68, 82, 54, and 95% for cows housed in pens containing NES, RS, SBMS, and DBMS, respectively. No association was found between HK score and teat position and no association was found between HK score and teat skin bacterial count. Bacterial counts of teat skin swabs from front teats of cows in pens containing RS and SBMS were significantly less than those of rear teats of cows in pens containing DBMS or NES. Teat skin bacterial counts were significantly greater for swabs obtained from teats of cows with udder hygiene scores of 3 and 4 as compared with swabs obtained from cows with cleaner udders. Of all udder conformation traits evaluated, only narrower rear teat placement was positively associated with bacterial counts on teat skin

  13. Effects of antibiotic dry-cow therapy and internal teat sealant on milk somatic cell counts and clinical and subclinical mastitis in early lactation.

    Science.gov (United States)

    Golder, H M; Hodge, A; Lean, I J

    2016-09-01

    The objective of this study was to determine the efficacy of an internal teat sealant (TS; Teatseal; Zoetis Australia, Silverwater, NSW, Australia), when used in combination with antibiotic dry-cow therapy (ADCT) administered at dry-off, on milk individual somatic cell count (ISCC), milk production and components, and the incidence of clinical and subclinical mastitis in dairy cows up to 60 d after calving, when compared with ADCT only. Multiparous Holstein, Jersey, or Holstein cross cows (n=2,200) from 8 farms in southern and eastern Australia were randomly assigned to treatment of all 4 quarters with ADCT alone or with ADCT plus TS (ADCT + TS) at dry-off in this randomized, multisite clinical trial. Individual milk yield, fat and protein percentages, and ISCC were measured at intervals of 14±3 d after calving for the first 60 d of lactation. The first measurement occurred between 10 and 24 d after calving. Clinical mastitis and health events were recorded from dry-off to 60 d of lactation. Milk samples were collected from first cases of clinical mastitis and subjected to bacteriology. Treatment and the interaction of treatment by time did not affect milk yield, ISCC weighted by milk yield, or fat and protein percentages. Treatment with ADCT + TS decreased geometric mean ISCC compared with treatment with ADCT alone over the first 60 d of lactation. Geometric mean ISCC (×10(3) cells/mL) was 32.0 [95% confidence interval (CI): 26.8 to 38.3] and 43.5 (95% CI: 36.2 to 52.1) for ADCT + TS and ADCT alone, respectively. The odds of at least 1 case of subclinical mastitis (ISCC ≥250,000 cells/mL) were 1.9 times higher (95% CI: 1.4 to 2.6) with ADCT alone in the first 60 d of lactation compared with ADCT + TS. Use of ADCT + TS reduced the estimated incidence of at least 1 case of subclinical mastitis on all 8 farms, compared with use of ADCT alone. Only 4 cows that calved 40 to 100 d after dry-off had a first case of clinical mastitis in the dry period. Five percent of

  14. Teat order affects postweaning behaviour in piglets

    Directory of Open Access Journals (Sweden)

    Roberta Sommavilla

    2015-09-01

    Full Text Available The objective of this study was to investigate if piglets that suck anterior teats differ from the others in the litter in birth weight, if they have higher growth rate during lactation, and if this affects behaviour and post-weaning weight gain, when piglets change to a solid diet. For this, the teat order of 24 litters was determined during suckling. Piglets were weaned on the 28thday of age, and 24 groups were formed, composed of one piglet that sucked on the first two pairs of teats (AT and three piglets that sucked on the other teats (OT. Even though weight at birth did not vary according to teat order, weight gain at weaning differed between the groups (AT: 6.64, S.E. 0.20kg, OT: 5.73, S.E. 0.13kg; P

  15. The use of an internal teat sealant in combination with cloxacillin dry cow therapy for the prevention of clinical and subclinical mastitis in seasonal calving dairy cows.

    Science.gov (United States)

    Runciman, D J; Malmo, J; Deighton, M

    2010-10-01

    Cows (n=2,053) from 6 seasonally calving dairy herds were enrolled in a trial to compare the efficacy of 2 dry cow treatments. Cows received either a combination dry cow therapy of 600 mg of cloxacillin (CL) followed by an internal teat sealant (ITS) containing 2.6 g of bismuth subnitrate in all 4 quarters immediately following their final milking for the season, or only an intramammary infusion of 600 mg of CL. All cases of clinical mastitis were recorded and cultured during the first 150 d of lactation in each herd, and cow somatic cell count (SCC) was measured between 7 and 50 d postcalving. A large difference was found between treatment groups in the rate at which cows were diagnosed with clinical mastitis over the first 21 d of lactation, after which time the rate at which cows were diagnosed with clinical mastitis was similar between treatment groups. Analysis of the relative proportions of cows with clinical mastitis was performed at both the gland and cow levels. The relative risk (RR) of clinical mastitis diagnosed within 21, 30, and 100 d of calving in a gland treated with the ITS-CL combination was, respectively, 0.30 [95% confidence interval (CI)=0.21-0.44], 0.39 (0.28-0.53), and 0.58 (0.46-0.75) that of the CL group. An interaction between treatment and previous SCC was found when clinical mastitis was analyzed at the cow level. In a subset of cows that had low SCC in their previous lactation, the RR of mastitis in cows with the ITS-CL combination within 21, 30, and 100 d of calving was, respectively, 0.54 (95% CI=0.33-0.87), 0.57 (0.37-0.88), and 0.69 (0.50-0.99) that of cows that received only CL at drying off. In the subset of cows that had at least 1 high SCC in the previous lactation, the RR of mastitis in the ITS-CL combination group within 21, 30, and 100 d of calving was, respectively, 0.26 (95% CI=0.16-0.44), 0.37 (0.24-0.57), and 0.72 (0.55-0.96) that of the CL-only group. The ITS-CL combination of dry cow treatments was associated with a

  16. Dental sealants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  17. A Novel Lactobacilli-Based Teat Disinfectant for Improving Bacterial Communities in the Milks of Cow Teats with Subclinical Mastitis

    Directory of Open Access Journals (Sweden)

    Jie Yu

    2017-09-01

    Full Text Available Teat disinfection pre- and post-milking is important for the overall health and hygiene of dairy cows. The objective of this study was to evaluate the efficacy of a novel probiotic lactobacilli-based teat disinfectant based on changes in somatic cell count (SCC and profiling of the bacterial community. A total of 69 raw milk samples were obtained from eleven Holstein-Friesian dairy cows over 12 days of teat dipping in China. Single molecule, real-time sequencing technology (SMRT was employed to profile changes in the bacterial community during the cleaning protocol and to compare the efficacy of probiotic lactic acid bacteria (LAB and commercial teat disinfectants. The SCC gradually decreased following the cleaning protocol and the SCC of the LAB group was slightly lower than that of the commercial disinfectant (CD group. Our SMRT sequencing results indicate that raw milk from both the LAB and CD groups contained diverse microbial populations that changed over the course of the cleaning protocol. The relative abundances of some species were significantly changed during the cleaning process, which may explain the observed bacterial community differences. Collectively, these results suggest that the LAB disinfectant could reduce mastitis-associated bacteria and improve the microbial environment of the cow teat. It could be used as an alternative to chemical pre- and post-milking teat disinfectants to maintain healthy teats and udders. In addition, the Pacific Biosciences SMRT sequencing with the full-length 16S ribosomal RNA gene was shown to be a powerful tool for monitoring changes in the bacterial population during the cleaning protocol.

  18. Teat apex colonization with coagulase-negative Staphylococcus species before parturition: Distribution and species-specific risk factors.

    Science.gov (United States)

    De Visscher, A; Piepers, S; Haesebrouck, F; De Vliegher, S

    2016-02-01

    Coagulase-negative staphylococci (CNS) are the main cause of bovine intramammary infections and are also abundantly present in extramammary habitats such as teat apices. Teat apex colonization (TAC) with CNS has already been explored in lactating dairy cows at the species level, whereas this is not true for dry cows and end-term heifers. Therefore, the aim of this observational study was to describe CNS TAC in nonlactating dairy cows and end-term heifers in Flemish dairy herds and to identify associated risk factors at the herd, cow, and quarter level. All CNS were molecularly identified to the species level using transfer RNA intergenic spacer PCR (tDNA-PCR) and sequencing of the 16S rRNA gene, allowing for species-specific statistical analyses using multivariable, multilevel logistic regression. Staphylococcus devriesei, Staphylococcus chromogenes, Staphylococcus haemolyticus, and Staphylococcus equorum were the most frequently isolated species. Staphylococcus chromogenes was the sole species colonizing teat apices of cows and heifers in all herds, whereas large between-herd differences were observed for the other species. Teat apices of red and white Holstein Friesians, of quarters dried off without an internal teat sealer, and swabbed in months with lower precipitation and higher ambient temperature were significantly more likely to be colonized by S. devriesei. Slightly dirty teat apices and teat apices swabbed in months with lower precipitation had higher odds of being colonized by S. chromogenes, whereas teat apices sampled in months with lower precipitation and higher ambient temperature were more likely to be colonized by S. haemolyticus. Dirty teat apices and teat apices swabbed in months with lower ambient temperature in combination with low precipitation had higher odds of being colonized by S. equorum. Diverse factors explaining CNS TAC, yet mostly related to humidity, ambient temperature, and hygiene, substantiate differences in epidemiological

  19. Systematic review on the use of matrix-bound sealants in pancreatic resection.

    Science.gov (United States)

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-11-01

    Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.

  20. The association between bedding material and the bacterial counts of Staphylococcus aureus, Streptococcus uberis and coliform bacteria on teat skin and in teat canals in lactating dairy cattle.

    Science.gov (United States)

    Paduch, Jan-Hendrik; Mohr, Elmar; Krömker, Volker

    2013-05-01

    Several mastitis-causing pathogens are able to colonize the bovine teat canal. The objective of this study was to investigate the association between the treatment of sawdust bedding with a commercial alkaline conditioner and the bacterial counts on teat skin and in the teat canal. The study used a crossover design. Ten lactating Holstein cows that were free of udder infections and mastitis were included in the study. The animals were bedded on either untreated sawdust or sawdust that had been treated with a hydrated lime-based conditioner. Once a day, fresh bedding material was added. After 3 weeks, the bedding material was removed from the cubicles, fresh bedding material was provided, and the cows were rotated between the two bedding material groups. Teat skin and teat canals were sampled using the wet and dry swab technique after weeks 1, 2, 3, 4, 5 and 6. Staphylococcus aureus, Streptococcus uberis, Escherichia coli and other coliform bacteria were detected in the resulting agar plate cultures. The treatment of the bedding material was associated with the teat skin bacterial counts of Str. uberis, Esch. coli and other coliform bacteria. An association was also found between the bedding material and the teat canal bacterial counts of coliform bacteria other than Esch. coli. For Staph. aureus, no associations with the bedding material were found. In general, the addition of a hydrated lime-based conditioner to sawdust reduces the population sizes of environmental pathogens on teat skin and in teat canals.

  1. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2012-06-01

    Full Text Available We evaluated the influence of photoactivation method and hydrophobic resin (HR application on the marginal and internal adaptation, hardness (KHN, and crosslink density (CLD of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10 and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL, no adhesive system + photoactivation of the sealant using the soft-start method (SS, HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  2. Sealants in dentistry: outcomes of the ORCA saturday afternoon symposium 2007

    NARCIS (Netherlands)

    Splieth, C.H.; Ekstrand, K.R.; Alkilzy, M.; Clarkson, J.; Meyer-Lueckel, H.; Martignon, S.; Paris, S.; Pitts, N.B.; Rickets, D.N.; van Loveren, C.

    2010-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally.

  3. Sealants in dentistry: outcomes of the ORCA Saturday Afternoon Symposium 2007

    DEFF Research Database (Denmark)

    Splieth, C H; Ekstrand, K R; Alkilzy, M

    2009-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally...

  4. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  5. Update on the development of a novel dry cow therapy using a bismuth-based intramammary teat seal in combination with the bacteriocin lacticin 3147

    Directory of Open Access Journals (Sweden)

    Crispie Fiona

    2004-11-01

    Full Text Available Public concerns over the widespread prophylactic use of antibiotics have led to a search for alternatives to dry cow therapy for the prevention of intramammary infections. A popular alternative is to infuse a teat seal at drying-off. The teat seal is a viscous non-antibiotic formulation and when it is infused into the teat canal and the teat sinus it forms an internal seal that provides a physical barrier to invasion by mastitis-causing pathogens. Enhancement of teat seal formulations may be achieved using non-antibiotic additives such as bacteriocins, potent proteins produced by some bacteria that have the ability to kill other microorganisms. This paper traces the history of investigations at Moorepark Research Centre into the efficacy of teat seal plus lacticin 3147, a bacteriocin produced by Lactococcus lactis DPC3147, in the prevention of intramammary infections in dry cows. Indications from on-going investigations are that a dry cow formulation combining the two products has considerable potential as a non-antibiotic prophylactic product.

  6. Congenital Absence of a Teat in a Japanese Black Heifer

    Directory of Open Access Journals (Sweden)

    Mohamed Elshabrawy Ghanem

    2011-01-01

    Full Text Available A case of Japanese Black heifer with a congenital absence of teat (athelia was observed at Highashi-Hiroshima Agricultural High School, Hiroshima Prefecture, Japan. The heifer was born after transfer of embryo from Japanese Black cattle. The sire of the heifer was a proven Japanese Black. The birth weight of the heifer was 27 kg. On physical examination of the heifer at 21 months after birth, the teat at fore left was absent and the remaining three teats were normal in shape without any physical abnormalities. Per rectal palpation of the genital organs revealed the normal cervix and uterine horns. It was difficult to palpate the ovaries due to the fat around the organs. Blood samples were taken for cytogenetic and DNA testing. The heifer had normal chromosomal set. The heifer was culled due to its mammary abnormality. This might be the first to report a case of congenital absence of a teat in Japanese Black heifers.

  7. Reduction of teat skin mastitis pathogen loads: differences between strains, dips, and contact times.

    Science.gov (United States)

    Enger, B D; Fox, L K; Gay, J M; Johnson, K A

    2015-02-01

    The purpose of these experiments was to (1) assess differences in mastitis pathogen strain sensitivities to teat disinfectants (teat dips), and (2) determine the optimum time for premilking teat dips to remain in contact with teat skin to reduce pathogen loads on teat skin. Two experiments were conducted using the excised teat model. In experiment 1, the differences in mastitis pathogen strain sensitivities to 4 commercially available dips (dip A: 1% H2O2; dip B: 1% chlorine dioxide; dip C: 1% iodophor; and dip D: 0.5% iodophor) were evaluated. Four strains of 11 common mastitis pathogens (Staphylococcus aureus, Streptococcus agalactiae, Mycoplasma bovis, Streptococcus dysgalactiae, Streptococcus uberis, Escherichia coli, Staphylococcus chromogenes, Staphylococcus epidermidis, Staphylococcus hyicus, Staphylococcus xylosus, and Staphylococcus haemolyticus) were tested. In experiment 2, the percentage log reduction of mastitis pathogens (Escherichia coli, Streptococcus uberis, Streptococcus dysgalactiae, Klebsiella species, Staphylococcus chromogenes, Staphylococcus haemolyticus, Staphylococcus xylosus, and Staphylococcus epidermidis) on teat skin with 3 commercially available teat dips: dip A; dip D; and dip E: 0.25% iodophor, using dip contact times of 15, 30, and 45 s, was evaluated. Experiment 1 results indicated significant differences in strain sensitivities to dips within pathogen species: Staphylococcus aureus, Staphylococcus chromogenes, and Streptococcus uberis. Species differences were also found where Mycoplasma bovis (97.9% log reduction) was the most sensitive to tested teat dips and Staphylococcus haemolyticus (71.4% log reduction) the most resistant. Experiment 2 results indicated that contact times of 30 and 45 s were equally effective in reducing recovered bacteria for dips D and E and were also significantly more effective than a 15-s contact time. No differences were seen in recovered bacteria between tested contact times after treatment with dip

  8. Relationship between teat-end callosity and occurrence of clinical mastitis

    NARCIS (Netherlands)

    Neijenhuis, F.; Barkema, H.W.; Hogeveen, H.

    2001-01-01

    A longitudinal study in 15 herds, with a total of 2157 cows, was conducted to examine the relationship between teat-end callosity (TEC) and the incidence of clinical mastitis. During the 1.5-yr study period, clinical mastitis was diagnosed by the farmers based on clinical signs. Teat-end callosity

  9. Iodide Residues in Milk Vary between Iodine-Based Teat Disinfectants

    NARCIS (Netherlands)

    French, Elizabeth A; Mukai, Motoko; Zurakowski, Michael; Rauch, Bradley; Gioia, Gloria; Hillebrandt, Joseph R; Henderson, Mark; Schukken, Ynte H; Hemling, Thomas C

    Majority of iodine found in dairy milk comes from the diet and teat disinfection products used during milking process. The objective of this study was to evaluate the effects of 4 iodine-based teat dips on milk iodide concentrations varying in iodine level (0.25% vs. 0.5%, w/w), normal low viscosity

  10. Decision tree analysis to evaluate dry cow strategies under UK conditions.

    Science.gov (United States)

    Berry, Elizabeth A; Hogeveen, Henk; Hillerton, J Eric

    2004-11-01

    Economic decisions on animal health strategies address the cost-benefit aspect along with animal welfare and public health concerns. Decision tree analysis at an individual cow level highlighted that there is little economic difference between the use of either dry cow antibiotic or an internal teat sealant in preventing a new intramammary infection in a cow free of infection in all quarters of the mammary gland at drying off. However, a potential net loss of over ł20 per cow might occur if the uninfected cow was left untreated. The only economically viable option, for a cow with one or more quarters infected at drying off, is antibiotic treatment, although a loss might still be incurred depending on the pathogen concerned and the cure rates achievable. There was a net loss for cows with quarters infected with Corynebacterium spp. at drying off, for both the teat sealant and untreated groups (ł22 and ł48, respectively) with only antibiotic-treated cows showing a gain.

  11. Pit and fissure sealants for preventing dental decay in permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2017-01-01

    to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Selection criteria......Background: Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries....... Further research with long follow-up is needed....

  12. Genetic relatedness and virulence factors of bovine Staphylococcus aureus isolated from teat skin and milk.

    Science.gov (United States)

    da Costa, L B; Rajala-Schultz, P J; Hoet, A; Seo, K S; Fogt, K; Moon, B S

    2014-11-01

    The objective of this study was to assess the role of teat skin colonization in Staphylococcus aureus intramammary infections (IMI) by evaluating genetic relatedness of Staph. aureus isolates from milk and teat skin of dairy cows using pulsed-field gel electrophoresis and characterizing the isolates based on the carriage of virulence genes. Cows in 4 known Staph. aureus-positive herds were sampled and Staph. aureus was detected in 43 quarters of 20 cows, with 10 quarters positive in both milk and skin (20 isolates), 18 positive only in milk, and 15 only on teat skin. Quarters with teat skin colonized with Staph. aureus were 4.5 times more likely to be diagnosed with Staph. aureus IMI than quarters not colonized on teat skin. Three main clusters were identified by pulsed-field gel electrophoresis using a cutoff of 80% similarity. All 3 clusters included both milk and skin isolates. The majority of isolates (72%) belonged to one predominant cluster (B), with 60% of isolates in the cluster originating from milk and 40% from teat skin. Genotypic variability was observed within 10 pairs (formed by isolates originating from milk and teat skin of the same quarter), where isolates in 5 out of the 10 pairs belonged to the same cluster. Forty-two virulence factors were screened using PCR. Some virulence factors were carried more frequently by teat skin isolates than by milk isolates or isolates from quarters with high somatic cell counts. Isolates in the predominant cluster B carried virulence factors clfA and clfB significantly more often than isolates in the minor clusters, which may have assisted them in becoming predominant in the herds. The present findings suggest that teat skin colonization with Staph. aureus can be an important factor involved in Staph. aureus IMI. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. The state-of-the-art of ART sealants.

    Science.gov (United States)

    Frencken, Jo E

    2014-03-01

    Sealing caries-prone pits and fissure systems is an effective caries-preventive measure. There are basically two types of sealant materials: glass-ionomer and resin-based materials. Low- and medium-viscosity glass-ionomers were initially used and showed a low level of retention. With the advent of the ART approach in the mid-nineties, high-viscosity glass-ionomers were introduced as sealant material and the retention rate of ART sealants increased substantially. As the effectiveness of a sealant is measured by its capacity to prevent (dentine) carious lesion development, sealant retention is considered a surrogate endpoint. The ART sealant protocol is described. Systematic reviews and meta-analysis covering low- medium- and high-viscosity glass-ionomer (ART) sealants have concluded that there is no evidence that either glass-ionomer or resin-based sealants prevent dentine carious lesions better. The annual dentine carious lesion development in teeth with high-viscosity glass-ionomer ART sealants over the first three years is 1%. These ART sealants have a high capacity of preventing carious lesion development. Because no electricity and running water is required, ART sealants can be placed both inside and outside the dental surgery. High-viscosity glass-ionomer ART sealants can be used alongside resin-based sealants.41:119-124

  14. Comparative study of resin sealant and resin modified glass ionomer as pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Shirin Malek

    2017-02-01

    Full Text Available The purpose of the present study was to compare the marginal integrity of resin modified glass ionomer cement with that of resin sealant, in vitro. Forty artificial pit and fissure cavities were prepared in occlusal surface of extracted premolar teeth by using ¼ round carbide bur. Cavities were condensed with artificial organic debris followed by cleaning with prophylaxis pumice brush and paste and then separated into two treatment groups. In Group A, 15 fissure cavities were sealed by resin sealant and in Group B, 15 fissure cavities were sealed by resin modified glass ionomer sealant. These specimens were subjected to thermo-cycling followed by dye penetration test. The remaining 5 cavities from each group were analyzed for debris score by the SEM. The results of the microleakage test showed that the efficacy of preventing microleakage of samples sealed by resin modified glass ionomer sealant was higher than the samples sealed by resin sealant. However, no significant differences were found. It can be concluded that use of resin modified glass ionomer sealant is a good alternative for sealing pits and fissures.

  15. Parametric Study of Sealant Nozzle

    Science.gov (United States)

    Yamamoto, Yoshimi

    It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.

  16. Retention of a resin-based sealant and a glass ionomer used as a fissure sealant: A comparative clinical study

    Directory of Open Access Journals (Sweden)

    Subramaniam P

    2008-09-01

    Full Text Available Sealing occlusal pits and fissures with resin-based sealants is a proven method of preventing occlusal caries. Retention of the sealant is very essential for its efficiency. This study evaluated the retention of glass ionomer used as a fissure sealant when compared to a self-cure resin-based sealant. One hundred and seven children between the ages of 6-9 years, with all four newly erupted permanent first molars were selected. Two permanent first molars on one side of the mouth were sealed with Delton, a resin-based sealant, and the contralateral two permanent first molars were sealed with Fuji VII glass ionomer cement. Evaluation of sealant retention was performed at regular intervals over 12 months, using Simonsen′s criteria. At the end of the study period, the retention of the resin sealant was seen to be superior to that of the glass ionomer sealant.

  17. Effect of disinfecting teats post-milking or pre- and post-milking on intramammary infection and somatic cell count.

    Science.gov (United States)

    Williamson, J H; Lacy-Hulbert, S J

    2013-09-01

    To determine the effects of (a) post-milking teat disinfection compared with no disinfection and (b) pre- and post-milking teat disinfection compared with post-milking disinfection alone, on the incidence of new intramammary infection (IMI), somatic cell count (SCC) and teat skin abnormalities in dairy cows. In Experiment 1, dairy cows in five dairy herds were randomly allocated to a post-milking teat disinfection group (n=230), that was sprayed with an iodine-based disinfectant (TeatguardPlus) for a complete lactation, or to a non-disinfected group (n=239). In Experiment 2, cows were randomly allocated to post-milking teat disinfection (n=239) or both pre- and post-milking teat disinfection (n=235), using a chloramine-T-based disinfectant (Teatsweet) for both treatments, from calving to 118-127 days in milk. The incidence of new IMI was determined by aseptic sampling of all quarters at calving, during lactation, and at trial end or at drying-off, with clinical mastitis cases sampled on detection. SCC and teat skin abnormalities were measured at 2-monthly intervals during lactation. In both experiments, disinfectant was applied by spray application. Cows that received post-milking teat disinfection had a lower incidence of new IMI caused by Staphylococcus aureus, Streptococcus uberis, Corynebacterium spp and coagulase negative staphylococci, had lower bulk milk SCC during lactation, and had fewer teat skin abnormalities compared with the non-disinfected cows (p disinfection, in addition to post-milking teat disinfection, did not reduce the incidence of new IMI for any pathogens and did not reduce SCC (p> 0.05). Post-milking teat disinfection applied as a spray is a key component in mastitis control in New Zealand. There was no benefit from the addition of pre-milking disinfection. This study confirms previous findings of the effectiveness of post-milking teat disinfection in reducing the incidence of IMI caused by the common mastitis-causing pathogens in New

  18. Moisture-tolerant resin-based sealant: A boon

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar Bhat

    2013-01-01

    Full Text Available Background and Objectives: Pit and fissure sealants are highly effective in preventing occlusal caries. The present study clinically evaluated and compared the retention and development of caries when sealed with moisture-tolerant resin-based sealant, conventional resin-based sealant with and without a bonding agent, and Glass Ionomer Cement Sealant in young permanent teeth. Materials and Methods: A total of 80 healthy cooperative children aged 6-9 years who were at high caries risk with all four newly erupted permanent first molars were included in the study. Teeth were divided into 4 groups using a full-factorial design, and each of the molars was sealed with the four different sealant material. Evaluation of sealant retention and development of caries was performed at 6 and 12 months using Modified Simonsen′s criteria. The data obtained were tabulated and subjected to statistical analysis using Kruskal-Wallis Test and Mann-Whitney Test. Result and Conclusion: The result from the present study indicated that moisture-tolerant resin-based sealant could be successfully used as a pit and fissure sealant because its hydrophilic chemistry makes it less technique sensitive and simplifies the sealant application procedure.

  19. Milk production in sows from a teat in second parity is influenced by whether it was suckled in first parity

    DEFF Research Database (Denmark)

    Farmer, Chantal; Palin, M-F; Theil, Peter Kappel

    2012-01-01

    ) different teats suckled in 2 subsequent lactations (treated, TRT; n = 25). In the first lactation, over half of the teats (Teats 1, 2, 5, 6, and 7 from 1 side of the udder, and Teats 3, 4, and 7 from the other side) were sealed with tape so that they were nonfunctional. During the next lactation, the CTL...... group had the same teats sealed as in the first lactation, whereas the opposite teats were sealed for the TRT group. In both parities, litters were standardized to 7 piglets around birth and to 6 piglets (1 piglet per available teat) at 48 h postpartum. During the second lactation, piglets were weighed...

  20. Dry cow therapy with a non-antibiotic intramammary teat seal - a review

    Directory of Open Access Journals (Sweden)

    Crispie Fiona

    2004-07-01

    Full Text Available Dry cow antibiotic therapy is used to eliminate existing intramammary infections and to prevent new infections in the dry period. It is implemented as part of a total management system known as the 'Five-Point Plan' for mastitis control. Recent public concerns over the widespread prophylactic use of antibiotics, coupled with an increasing interest in organic farming, have lead to a re-evaluation of the treatment of cows at drying-off. As a result, attention has focussed on the use of novel alternatives to antibiotic therapy at the end of lactation. One such therapy involves the application of a non-antibiotic bismuth-based intramammary teat seal designed for use in cows with low cell counts at the end of lactation. Like the keratin plug that forms naturally in teats of cows that have been dried-off, teat seal forms a physical barrier to invading pathogens. To date, a number of independent studies have shown that teat seal is as effective as traditional dry cow antibiotic products in preventing the occurrence of new infection during the dry period in cows with somatic cell counts of ≤200,000 cells ml-1 at drying-off. This paper reviews the efficacy of teat seal in preventing dry period mastitis in both conventional and organic dairying systems.

  1. Use of sealants: societal and professional factors.

    Science.gov (United States)

    Frazier, P J

    1984-02-01

    At present, sealant use continues at a low level in private practice by dentists and hygienists, and is moderate in community programs although there is high interest in their use in public health settings. Widespread delegation of sealant application to hygienists has not occurred even though the majority of state dental practice acts allow it, and even though practicing hygienists are highly interested in applying sealants. Use in federally sponsored programs is minimal or nonexistent. Information about sealants and adequate clinical experience in their application appear minimal in dental training institutions, and few opportunities have existed for continuing education. Generally, knowledge about sealants among dentists is low; many hold doubtful opinions. Insurance carriers, including commercial, provider, and governmental programs, appear reluctant to reimburse for sealants without purchaser demand and organized dentistry's blessings. Although society emphasizes patient rights to informed consent, few opportunities exist for the public, including group insurance purchasers and union negotiators, to learn about sealant use in conjunction with appropriate fluoride use. Public educational materials are sparse. Manufacturer marketing efforts at present, aimed at providers alone, are at best minimal, with a few exceptions; those targeting the public are nonexistent. Organized dentistry's Council statements may have contributed to a constriction, to date, in the flow of public information about sealants from industry. Lack of communication, or miscommunication, between practitioners and dental scientists has resulted in much misinformation and confusion about the value of sealants and their use. And, the contemporary status of dental manpower and the economy of dental practice in the private sector appear to have provided an infertile environment for acceptance of sealants as a primary preventive technology. In the public sector, interest in sealants is high but

  2. Growth of Cinta Senese piglets as affected by location of the suckled teat

    Directory of Open Access Journals (Sweden)

    Martina Bianchi

    2010-01-01

    Full Text Available The experimental animals were 18 Cinta Senese sows (7 primiparous and 11 multiparous and relative purebred off-  spring. Individual weight of piglets was recorded at birth (or shortly afterwards to the nearest 50 g and subsequently  every 3-5 days up to weaning. At each recording, piglets were ranked in decreasing order according to weight within their  respective litters. The behavior of a subsample of 8 sows and litters was observed during suckling, by recording the  teat–piglet coupling. The sows had 12 functional teats, equally distributed in the two symmetric rows, that were num-  bered as pairs in the antero-posterior direction.  Starting from the third week, piglets of multiparous sows showed a faster growth rate than those of the primiparous ones.  Repeatability of the piglets’ weight during the suckling period was high (r = 0.56 and repeatability of rank was even  higher, but decreased up to weaning. Anterior teats were the most occupied and showed the highest suckling fidelity  (consistency of suckling position. Various statistical analyses about the dependence of piglet weight (or weight rank with-  in litter on teat order indicated the highest milk productivity of the first teats and the lowest of the 5th & 6th teat pairs.

  3. Communications of Staphylococcus aureus and non-aureus Staphylococcus species from bovine intramammary infections and teat apex colonization.

    Science.gov (United States)

    Mahmmod, Yasser S; Klaas, Ilka Christine; Svennesen, Line; Pedersen, Karl; Ingmer, Hanne

    2018-05-16

    The role of non-aureus staphylococci (NAS) in the risk of acquisition of intramammary infections with Staphylococcus aureus is vague and still under debate. The objectives of this study were to (1) investigate the distribution patterns of NAS species from milk and teat skin in dairy herds with automatic milking systems, and (2) examine if the isolated NAS influences the expression of S. aureus virulence factors controlled by the accessory gene regulator (agr) quorum sensing system. In 8 herds, 14 to 20 cows with elevated somatic cell count were randomly selected for teat skin swabbing and aseptic quarter foremilk samples from right hind and left front quarters. Teat skin swabs were collected using the modified wet-dry method and milk samples were taken aseptically for bacterial culture. Colonies from quarters with suspicion of having NAS in milk or teat skin samples (or both) were subjected to MALDI-TOF assay for species identification. To investigate the interaction between S. aureus and NAS, 81 isolates NAS were subjected to a qualitative β-galactosidase reporter plate assay. In total, 373 NAS isolates were identified representing 105 from milk and 268 from teat skin of 284 quarters (= 142 cows). Sixteen different NAS species were identified, 15 species from teat skin and 10 species from milk. The most prevalent NAS species identified from milk were Staphylococcus epidermidis (50%), Staphylococcus haemolyticus (15%), and Staphylococcus chromogenes (11%), accounting for 76%. Meanwhile, the most prevalent NAS species from teat skin were Staphylococcus equorum (43%), S. haemolyticus (16%), and Staphylococcus cohnii (14%), accounting for 73%. Using reporter gene fusions monitoring transcriptional activity of key virulence factors and regulators, we found that out of 81 supernatants of NAS isolates, 77% reduced expression of hla, encoding a-hemolysin, 70% reduced expression of RNAIII, the key effector molecule of agr, and 61% reduced expression of spa encoding

  4. Defining standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to mastitis pathogens.

    Science.gov (United States)

    Schukken, Y H; Rauch, B J; Morelli, J

    2013-04-01

    The objective of this paper was to define standardized protocols for determining the efficacy of a postmilking teat disinfectant following experimental exposure of teats to both Staphylococcus aureus and Streptococcus agalactiae. The standardized protocols describe the selection of cows and herds and define the critical points in performing experimental exposure, performing bacterial culture, evaluating the culture results, and finally performing statistical analyses and reporting of the results. The protocols define both negative control and positive control trials. For negative control trials, the protocol states that an efficacy of reducing new intramammary infections (IMI) of at least 40% is required for a teat disinfectant to be considered effective. For positive control trials, noninferiority to a control disinfectant with a published efficacy of reducing new IMI of at least 70% is required. Sample sizes for both negative and positive control trials are calculated. Positive control trials are expected to require a large trial size. Statistical analysis methods are defined and, in the proposed methods, the rate of IMI may be analyzed using generalized linear mixed models. The efficacy of the test product can be evaluated while controlling for important covariates and confounders in the trial. Finally, standards for reporting are defined and reporting considerations are discussed. The use of the defined protocol is shown through presentation of the results of a recent trial of a test product against a negative control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. The effect of post milking test dip and suckling on teat skin condition, bacterial colonisation, and udder health

    DEFF Research Database (Denmark)

    Rasmussen, M.D.; Larsen, H.D.

    1998-01-01

    The teat skin of cows was scored (1 : smooth as silk; 2: smooth; 3: slightly rough; 4: rough; 5: cracked; and 6: sores) by trained technicians who moved their fingers down the barrel of the teat with a light touch. Technicians ranked the same population of teats in the same rank order, but their ...

  6. The pore of the leaf cavity of Azolla species: teat cell differentiation and cell wall projections.

    Science.gov (United States)

    Veys, P; Lejeune, A; Van Hove, C

    2002-02-01

    The differentiation of the specialized secretory teat cells of the leaf cavity pore of Azolla species was investigated at the ultrastructural level with emphasis on their peculiar cell wall projections. The results indicated that the projections are formed as soon as the teat cells complete their differentiation and that their production is principally associated with changes in endoplasmic reticulum profiles. The number of projections increases with the teat cell age and is stimulated under salt and P deficiency stresses. Salt stress also promotes their emergence on Azolla species that under normal conditions do not produce projections. Cytochemical tests on different Azolla species showed that the projection composition is almost identical: proteins, acidic polysaccharides, and pectin are always detected. This study revealed that Azolla teat cell projections differ fundamentally from other types of hitherto described cell wall projections that are considered as remnant structures from cell separation. In contrast, in Azolla teat cells projections are actively produced and compounds are excreted by an exocytotic mechanism. The possible role of the projections in the symbiosis of Azolla spp. with Anabaena azollae is discussed.

  7. Prepartum teat apex colonization with Staphylococcus chromogenes in dairy heifers is associated with low somatic cell count in early lactation.

    Science.gov (United States)

    De Vliegher, S; Laevens, H; Devriese, L A; Opsomer, G; Leroy, J L M; Barkema, H W; de Kruif, A

    2003-04-02

    A high number of dairy heifers freshen with udder health problems. The prevalence of teat apex colonization (TAC) with Staphylococcus chromogenes, one of the most widespread coagulase-negative staphylococci (CNS) in milk samples from freshly calved dairy heifers, was measured cross-sectionally in non-lactating heifers on eight commercial dairy farms in Belgium. The influence of age on this prevalence, and the association between teat apex colonization with S. chromogenes prepartum and quarter milk somatic cell count (SCC) in early lactation were studied. In total, 492 teat apices were sampled from 123 heifers. The age of the heifers varied from 8 to 34 months. Overall, 20% of the heifers had at least one teat apex colonized with S. chromogenes. Of all teats sampled, 10% were colonized with S. chromogenes. The chance of having at least one teat apex colonized with S. chromogenes increased with age of the heifer. The presence of prepartum teat apex colonization with S. chromogenes was not associated with intramammary infection (IMI) early postpartum with the same bacterium. On the contrary, teat apex colonization with S. chromogenes prepartum appeared to protect quarters in the first few days of lactation from having somatic cell count >or=200000cells/ml milk, commonly accepted as the threshold for intramammary infection.

  8. Effect of liner design, pulsator setting, and vacuum level on bovine teat tissue changes and milking characteristics as measured by ultrasonography

    Directory of Open Access Journals (Sweden)

    Gleeson David E

    2004-05-01

    Full Text Available Friesian-type dairy cows were milked with different machine settings to determine the effect of these settings on teat tissue reaction and on milking characteristics. Three teat-cup liner designs were used with varying upper barrel dimensions (wide-bore WB = 31.6 mm; narrow-bore NB = 21.0 mm; narrow-bore NB1 = 25.0 mm. These liners were tested with alternate and simultaneous pulsation patterns, pulsator ratios (60:40 and 67:33 and three system vacuum levels (40, 44 and 50 kPa. Teat tissue was measured using ultrasonography, before milking and directly after milking. The measurements recorded were teat canal length (TCL, teat diameter (TD, cistern diameter (CD and teat wall thickness (TWT. Teat tissue changes were similar with a system vacuum level of either 50 kPa (mid-level or 40 kPa (low-level. Widening the liner upper barrel bore dimension from 21.0 mm (P

  9. Durability of building joint sealants

    Science.gov (United States)

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  10. In vitro growth inhibition of major mastitis pathogens by Staphylococcus chromogenes originating from teat apices of dairy heifers.

    Science.gov (United States)

    De Vliegher, S; Opsomer, G; Vanrolleghem, A; Devriese, L A; Sampimon, O C; Sol, J; Barkema, H W; Haesebrouck, F; de Kruif, A

    2004-07-14

    Earlier field observations suggest that teat apex colonization by Staphylococcus chromogenes pre-partum in dairy heifers protects udder quarters against elevated somatic cell counts early post-partum. To explain these findings, the in vitro inhibitory capability of S. chromogenes from teat apices of heifers towards some major mastitis pathogens was tested using a modified cross-streaking method. Two out of 10 S. chromogenes isolates, both originating from two different teats from the same heifer, consistently inhibited growth of all Staphylococcus aureus, Streptococcus dysgalactiae, and Streptococcus uberis strains, but none of the Escherichia coli strains. The present study, therefore, supports the protective effect of teat apex colonization by S. chromogenes by in vitro production of inhibitory substances.

  11. Dental Sealants

    Science.gov (United States)

    ... that protect the chewing surfaces of children’s back teeth from tooth decay. Overall, the prevalence of sealants in children’s and adolescent’s teeth has increased since the early 1970s. In spite ...

  12. In vitro efficacy of teat antiseptics against Staphylococcus aureus strains isolated from bovine mastitis

    Directory of Open Access Journals (Sweden)

    Renata Paoli Santos

    2016-08-01

    Full Text Available The process of teat disinfection is a widely accepted component of successful mastitis control programs by reducing the number of bacteria on the teat skin and healing teat lesions. For contagious pathogens such as Staphylococcus aureus, post-milking teat disinfection remains a simple, effective and economical practice for prevention of new intramammary infections (IMIs of lactating dairy cows. Despite the universal acceptance of teat dipping as a method of mastitis control, variations in the susceptibility and resistance profile of mastitis pathogens among antiseptics have been described. Thus, here we sought to explore the in vitro efficacy of the followings antiseptics against S. aureus isolated from IMIs: chlorhexidine (2.0%, chlorine (2.5%, quarternary ammonium (4.0%, lactic acid (2.0% and iodine (0.6%. We used 50 S. aureus strains isolated from bovine IMIs from 50 dairy herds located at Minas Gerais, São Paulo, Paraná and Rio Grande do Sul States (Brazil. The antiseptics were evaluated at four different specific intervals (15, 30, 60 and 300 s. We found a higher activity for quarternary ammonium and chlorhexidine against S. aureus at all time-points, followed by iodine and then chlorine. Lactic acid treatment produced the worst results for all time-points and strains. Due to variations in the sensitivity and resistance profile of antiseptics against S. aureus isolated from IMIs, the effectiveness of the antiseptics against the major mastitis pathogens should be periodically evaluated in dairy farms in an attempt to reduce the rate of new IMIs in the herd.

  13. Do light cured ART conventional high-viscosity glass-ionomer sealants perform better than resin-composite sealants: a 4-year randomized clinical trial

    NARCIS (Netherlands)

    Zhang, W.; Chen, X.; Fan, M.W.; Mulder, J.; Huysmans, M.C.D.N.J.M.; Frencken, J.E.F.M.

    2014-01-01

    OBJECTIVE: The hypotheses tested were: the cumulative survival rates of dentin caries lesion-free pits and fissures of ART conventional high-viscosity glass-ionomer sealants with light-curing (high-intensity LED) and glass-carbomer sealants are higher than those of conventional ART sealants and

  14. Decision tree analysis to evaluate dry cow strategies under UK conditions

    OpenAIRE

    Berry, E.A.; Hogeveen, H.; Hillerton, J.E.

    2005-01-01

    Economic decisions on animal health strategies address the cost-benefit aspect along with animal welfare and public health concerns. Decision tree analysis at an individual cow level highlighted that there is little economic difference between the use of either dry cow antibiotic or an internal teat sealant in preventing a new intramammary infection in a cow free of infection in all quarters of the mammary gland at drying off. However, a potential net loss of over pound20 per cow might occur ...

  15. Sealants for preventing dental decay in the permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2013-01-01

    of bias and two studies at high risk of bias), 482 children evaluated; risk ratio (RR) 0.24, 95% CI 0.12 to 0.45, one study at unclear risk of bias, 203 children evaluated).- Glass ionomer sealant compared with no sealant: There is insufficient evidence to make any conclusions about whether glass ionomer......, outcomes, time of outcomes reported and background fluoride exposure if this was reported.Fifteen trials compared glass ionomer with resin sealants and there is insufficient evidence to make any conclusions about the superiority of either of the two materials. Although there were 15 trials the event rate...... was very low in many of these which restricted their contribution to the results.Three trials compared resin-modified glass ionomer with resin sealant and reported inconsistent results.Two small low quality trials compared polyacid-modified resin sealants with resin sealants and found no difference...

  16. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  17. DISTRIBUTION OF COAGULASE-NEGATIVE STAPHYLOCOCCI SPECIES ON TEAT SKIN AND IN MILK SAMPLES FROM DAIRY COWS IN AUTOMATIC MILKING SYSTEMS

    DEFF Research Database (Denmark)

    Mahmmod, Yasser Saadeldien Ibrahim; Svennesen, Line; Pedersen, Karl

    ) to identify the predisposing cow level risk factors for specific CNS IMI and teat colonization.In each herd, 30- 40 cows with somatic cell counts > 200,000 cells/ml in the previous milk recording are randomly selected and teat skin swabs and aseptic quarter foremilk samples are taken. Teat skin swabs...... are collected using a modified wet-dry method. First a wet swab immersed in ¼ Ringer’s solution followed by a dry swab are rotated 360° around the teat canal orifice and both swab tips transferred into one tube with 2 ml of ¼ Ringer’s solution. Samples are transported on ice for culturing in the laboratory...

  18. Cross-sectional study to identify staphylococcal species isolated from teat and inguinal skin of different-aged dairy heifers.

    Science.gov (United States)

    Adkins, P R F; Dufour, S; Spain, J N; Calcutt, M J; Reilly, T J; Stewart, G C; Middleton, J R

    2018-04-01

    The purpose of this study was to describe the prevalence and distribution of staphylococcal species on the teat and inguinal skin of dairy heifers across the various stages of the heifer life cycle. The cross-sectional study included 106 Holstein heifers with an age range of 0 d to 27 mo that were selected from 11 different groups, based on housing type and age, on a single dairy operation. A composite swabbing sample including all 4 teats and a second composite sample including both inguinal regions of each heifer were collected using gas-sterilized electrostatic dusters (Swiffers; Procter and Gamble, Cincinnati, OH). Swabbing samples were mixed with 10 mL of sterile saline, agitated, and cultured on mannitol salt agar plates. At 24 h, plates were read and up to 10 staphylococcal colonies were saved for further analysis. Staphylococcal isolates were speciated using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or PCR amplification and partial sequencing of rpoB or tuf. The prevalence of staphylococci was compared between the inguinal and teat regions using the chi-squared or Fisher's exact test, as applicable. Logistic regression models were used to investigate the relationship between a heifer's age (treated as a quantitative continuous variable) and the probability of isolating a given staphylococcal species from a given body site (inguinal region or teats). Overall, the most common species identified were Staphylococcus haemolyticus followed by Staphylococcus chromogenes, Staphylococcus xylosus, Staphylococcus devriesei, and Staphylococcus sciuri. Staphylococcus aureus was more prevalent on the teat than in the inguinal region, whereas Staphylococcus arlettae was more prevalent in the inguinal region than on the teat. All other staphylococcal species were as likely to be found on the teat skin as the inguinal region skin. Isolation from the inguinal and teat skin was associated with age for Staphylococcus agnetis, S. chromogenes

  19. Glass ionomer ART sealants in Chinese school children-6-year results.

    Science.gov (United States)

    Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu

    2013-09-01

    To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    Directory of Open Access Journals (Sweden)

    Felice Esposito

    Full Text Available Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks.A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors.A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p0.05. Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in

  1. Development of a Novel Alginate-Based Pleural Sealant

    Science.gov (United States)

    2016-07-01

    thoracotomy is performed on a anesthetized ventilated live rat (a), an incision is made to induce pleural air leak (b), and sealant material [ liquid ...AWARD NUMBER: W81XWH-15-1-0107 TITLE: Development of a Novel Alginate-Based Pleural Sealant PRINCIPAL INVESTIGATOR: Daniel J. Weiss MD PhD...SUBTITLE Development of a Novel Alginate-Based Pleural Sealant 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0107 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  2. Role of Fibrin Sealants in Liver Surgery

    NARCIS (Netherlands)

    de Boer, Marieke T.; Boonstra, Elizabeth A.; Lisman, Ton; Porte, Robert J.

    2012-01-01

    Background: Fibrin sealants are widely used in liver surgery. The aim of this article is to review the literature on evidence of hemostatic and biliostatic capacities of different fibrin sealants in liver surgery. Methods: In PubMed, a literature search was done with the search terms 'fibrin

  3. Two-year survival of glass ionomer sealants placed as part of ...

    African Journals Online (AJOL)

    , ... Results: The two-year cumulative survival of the sealants was 10.9%, and the survival of the sealants was not significantly affected by the GIC material brand and the toothisolation method used. However, slightly more sealants survived ...

  4. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  5. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    Science.gov (United States)

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  6. Toxicity of coal-tar and asphalt sealants to eastern newts, Notophthalmus viridescens

    Energy Technology Data Exchange (ETDEWEB)

    Bommarito, T.; Sparling, D.W.; Halbrook, R.S. [South Illinois University, Carbondale, IL (United States). Cooperative Wildlife Research Laboratory

    2010-09-15

    Between 1970 and 2000 the concentration of total polycyclic aromatic hydrocarbons (TPAH) in several lakes across the country increased whereas those of other persistent organic pollutants (POPs) tended to remain stable or declined. Urbanized watersheds experienced greater rises in TPAH concentration compared to non-urban lakes. Sources for urban PAHs include industrial wastes, vehicular exhausts and oil leaks and sealants from pavement surfaces. Both coal-tar and asphalt sealants are used to protect surfaces but runoff from surfaces coated with coal-tar can have mean concentrations of 3500 mg TPAHs kg{sup -1}, much higher than runoff from asphalt-sealed or cement surfaces. Unaltered parent compounds of PAHs can have many lethal and sublethal toxic effects, but oxidation and UV radiation can alter the toxicity of these compounds, sometimes creating degradates that are many times more toxic than parent compounds. The purposes of this study were to determine if coal-tar sealants can be toxic to adult eastern newts (Notophthalmus viridescens) and to compare the toxicity of coal-tar sealant to that of asphalt sealant. Newts were exposed to sediments containing dried sealants ranging from 0 mg kg{sup -1} to 1500 mg kg{sup -1} under simultaneous exposure to UV radiation and visible light to determine concentration/response relationships. No significant mortality occurred with any treatment. Significant effects due to sealants included decreased righting ability and diminished liver enzyme activities. Coal-tar sealant was more effective in inducing these changes than was asphalt sealant.

  7. Effect of chain extender on properties of silicone rubber sealant

    Science.gov (United States)

    Liu, Jiesheng; Wu, Shaopeng; Mi, Yixuan; Zhu, Guojun; Zheng, Shaoping

    2010-03-01

    The room-temperature vulcanizing silicone rubber sealant was prepared with chain extender. The effect of chain extender on the properties of silicone rubber sealant was discussed. The composite samples with chain extender were investigated from the aspects of tack-free time, cross-linkage density, hardness (penetration number) and adhesive strength with the concrete slab. It was found that the adding of the chain extender effectively makes the molecular chain length increase and causes the mechanical properties improvement. In addition, the increase in the amount of the chain extender reduces the cross-linkage density and hardness of silicone rubber sealant, which is accompanied with a decrease in the tack-free time. Adhesive strength is one of the most important requirements for sealant. The effect of chain extender on the adhesive strength was also investigated in this study. It was found that the increase in the amount of the chain extender makes the adhesive strength between the sealant and the concrete slab decrease.

  8. A 1-year clinical evaluation of fissure sealants on permanent first molars

    Directory of Open Access Journals (Sweden)

    Nupur Ninawe

    2012-01-01

    Full Text Available Objective : To evaluate and compare the retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants. Materials and Methods : Thirty children between the ages of 6 and 10 years, who were attending the school health program regularly, had participated in the study. A split-mouth design was used in which the two fissure sealants (Helioseal-F and Glass ionomer Fuji VII were randomly placed in 60 matched contralateral pairs of permanent molar teeth. Sealants were rated by a single trained and calibrated examiner using mouth mirrors and probes following the US Public Health Service criteria. The sealants were evaluated at 3 months, 6 months and 1 year intervals. Results : The data obtained for retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants were tabulated and compared statistically using the Chi-square test of significance. Conclusion : The Helioseal-F sealant was better than the Glass ionomer Fuji VII sealant with respect to retention, anatomical form and surface texture. Both the materials showed similar results with respect to marginal discoloration.

  9. Tensile strength of biological fibrin sealants: a comparative study.

    Science.gov (United States)

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    International Nuclear Information System (INIS)

    Bryer, Pamela J.; Scoggins, Mateo; McClintock, Nancy L.

    2010-01-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, and 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. - Coal-tar pavement sealants degrade stream invertebrate communities.

  11. Comparison of microleakage between flowable nanocomposite, flowable Composite and Conventional sealant in fissure sealant therapy of the permanent teeth: an in- vitro study

    Directory of Open Access Journals (Sweden)

    Sara Maleki Kambakhsh

    2016-11-01

    Full Text Available Background and Aim: Novel dental materials including nanocomposites have been introduced in recent years. It is claimed that they have superior properties such as high esthetic., low wear, increased filler content resulting in better mechanical properties, and releasing ions i.e. fluoride and amorphous calcium phosphate that are important for enamel remineralization. Considering these features, if they have retention and microleakage rates comparable with conventional sealants, these materials can be appropriate alternatives to conventional resin sealants in future. The current study aimed at comparing . microleakage of a flowable nanocomposite, a flowable composite , and a conventional sealant in fissure sealant therapy of the permanent teeth. Materials and Methods: First of all ,42 extracted sound human maxillary first premolars were collected and were randomly divided into 3 equal groups. Then the teeth were embedded in self-cure acrylic resin. Occlusal fissures of the samples were cleaned using explorer, enameloplasty with ¼ round diamond bur and water/air spray was done. The prepared surfaces were etched using 36% phosphoric acid gel for 15s, rinsed and dried. Bonding agent was placed in the pits and fissures, cured for 10s after thinning with air. In the first, second , and the third group conventional sealant, flowable composite , and flowable nanocomposite were placed, respectively; and light cured for 40s. The samples were thermocycled (1000 cycles between 5-55ºC and then immersed in 2% basic Fuchsine solution for 24hs. They were then cut bucculingually and microleakage evaluation was done using stereomicroscope. The obtained data was analyzed using Kruskal wallis tests. Results: There was no significant difference in microleakage rate of the study groups. (P>0.05. Conclusion: Considering the condition of the study, it can be concluded that flowable composite and flowable nanocomposite can be used as suitable alternatives to

  12. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Kannan, Kurunthachalam, E-mail: Kurunthachalam.kannan@health.ny.gov [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Biochemistry Department, Faculty of Science, Experimental Biochemistry Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah (Saudi Arabia)

    2016-11-15

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  13. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    International Nuclear Information System (INIS)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan; Kannan, Kurunthachalam

    2016-01-01

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  14. Reimbursement rates and policies for primary molar pit-and-fissure sealants across state Medicaid programs.

    Science.gov (United States)

    Chi, Donald L; Singh, Jennifer

    2013-11-01

    Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.

  15. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Hiiri, Anne; Nordblad, Anne

    2008-01-01

    BACKGROUND: Although pit and fissure sealants are effective in preventing caries, their efficacy may be related to the caries prevalence in the population. OBJECTIVES: The primary objective of this review was to evaluate the caries prevention of pit and fissure sealants in children and adolescents...... for comparison of sealant versus sealant. Five split-mouth studies and one parallel group study with 5 to 10 year old children found a significant difference in favour of second or third generation resin-based sealants on first permanent molars, compared to a control without sealant, with a pooled RR of 0.13 (95...... sealant group; 27% of sealed surfaces were decayed compared to 77% of surfaces without sealant.The results of the studies comparing different sealant materials were conflicting. AUTHORS' CONCLUSIONS: Sealing is a recommended procedure to prevent caries of the occlusal surfaces of permanent molars...

  16. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Bryer, P.J.; Scoggins, M.; McClintock, N.L. [Lamar University, Beaumont, TX (United States). Dept. of Biology

    2010-05-15

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments.

  17. Sealants fight back aginst bacteria.

    Science.gov (United States)

    Moran, Mike

    2008-09-01

    Mike Moran, business development manager, Industrial Construction, at Bostik, explains how a range of new sealants increase protection in hospital bathrooms, shower rooms and kitchen facilities against healthcare-acquired infections.

  18. Evaluation of a sealant intervention program among Taiwanese aboriginal schoolchildren

    Directory of Open Access Journals (Sweden)

    Hui-Ju Hsieh

    2014-06-01

    Conclusion: The application of pit-and-fissure sealants was 94.54% effective in preventing caries on newly erupted permanent molars among Taiwanese aboriginal schoolchildren. Complete sealant failure demonstrated a high risk for caries, and such teeth should immediately be resealed.

  19. Bacterial counts on teat skin and in new sand, recycled sand, and recycled manure solids used as bedding in freestalls.

    Science.gov (United States)

    Rowbotham, R F; Ruegg, P L

    2016-08-01

    On modern dairy farms, environmental mastitis pathogens are usually the predominant cause of mastitis, and bedding often serves as a point of exposure to these organisms. The objective of this longitudinal study was to determine bacterial populations of 4 different bedding types [deep-bedded new sand (NES), deep-bedded recycled sand (RS), deep-bedded manure solids (DBMS), and shallow-bedded manure solids over foam core mattresses (SBMS)] and of teat skin swabs of primarily primiparous cows housed in a single facility over all 4 seasons. Samples of bedding were collected weekly (n=49wk) from pens that each contained 32 lactating dairy cows. Throughout the length of the same period, composite swabs of teat skin were collected weekly from all cows before and after premilking teat sanitation. Median numbers of streptococci and streptococci-like organisms (SSLO) were >8.6×10(6) cfu/g and >6.9×10(3) cfu/teat swab for all bedding types and teat swabs, respectively. Numbers of SSLO were greatest in samples of SBMS (2.1×10(8) cfu/g) and least in samples of NES (8.6×10(6) cfu/g), RS (1.3×10(7) cfu/g), and DBMS (1.7×10(7) cfu/g). Numbers of gram-negative bacteria in bedding (5.5×10(4) to 1.2×10(7) cfu/g) were fewer than numbers of SSLO (8.6×10(6) to 2.1×10(8) cfu/g). Numbers of coliform bacteria were greatest in samples of DBMS (2.2×10(6) cfu/g) and least in samples of NES (3.6×10(3) cfu/g). In general, the relative number of bacteria on teat skin corresponded to exposure in bedding. Numbers of gram-negative bacteria recovered from prepreparation teat swabs were greatest for cows bedded with DBMS (1.0×10(4) cfu/swab) and RS (2.5×10(3) cfu/swab) and least for cows bedded with NES (5.8×10(2) cfu/swab). Median numbers of coliform and Klebsiella spp. recovered from prepreparation teat swabs were below the limit of detection for all cows except those bedded with DBMS. Numbers of SSLO recovered from prepreparation teat swabs were least for cows bedded with DBMS (6.9

  20. A main factors affecting average number of teats in pigs

    Directory of Open Access Journals (Sweden)

    Emil Krupa

    2016-09-01

    Full Text Available The influence of factors (breed, year and season of farrowing, herd, parity order, sire of litter, total number of born piglets - TNB, number of piglets born alive - NBA, number of weaned piglets - NW, and linear and quadratic regression on the number of teats, found for all piglets in the litter till ten days after born, expressed as arithmetic mean for each litter as sum of all teats number of each piglet in appropriate litter divided by number of piglets in this litter at first litter (ANT1 and second and subsequent litters (ANT2+ were analysed. The coefficient of determination was 0.46 and 0.33 for ANT1 and ANT2+, respectively. The statistically high influence (P<0.001 on ANT1 and ANT2+ was determined for year and season of farrowing, herd, parity order (only for ANT2+ and sire of litter effects. Impact of breed was found only on ANT2+ (P<0.001. The rest of factors have negligible of no impact on traits. Based on the data available for analyses, obtained results will serve as a relevant set-up in developing the model for genetic evaluation for these traits.

  1. Effect of an Antibacterial Monomer on the Antibacterial Activity of a Pit-and-Fissure Sealant.

    Directory of Open Access Journals (Sweden)

    Fan Yu

    Full Text Available Resin-based pit-and-fissure sealants are often used to form a barrier on the occlusal surface of molars to treat caries lesions; however, bacteria can remain in the pit and fissures without detection, increasing the risk of secondary caries. Sealants with antimicrobial properties or microbial repellent actions might be advantageous. The aim of this study was to assess the inhibitory effect of a 2-methacryloxylethyl dodecyl methyl ammonium bromide (MAE-DB-incorporated sealant against Streptococcus mutans. MAE-DB (4% wt was incorporated into a commercially available sealant, Eco-S resin-based pit-and-fissure sealant (Vericom Co., Ltd., Korea; a sealant without MAE-DB served as a negative control, and Clinpro™ Sealant (3M™ ESPE™, a fluoride-releasing resin, was used as a commercial control. The effects of the cured sealants and their eluents on the growth of S. mutans were determined according to colony-forming unit counts and metabolic tests. The effects of the cured sealants on the adherence and membrane integrity of S. mutans were investigated using confocal laser-scanning microscopy (CLSM in conjunction with fluorescent indicators. Compared with the negative control and commercial control, the cured MAE-DB-incorporated pit-and-fissure sealant exhibited a significant inhibitory effect on the growth of S. mutans (P < 0.05, whereas the eluents did not show any detectable antibacterial activity. The commercial control also showed no detectable bactericidal activity. Moreover, the aged experimental material retained its property of contact inhibition of biofilm formation. The fluorescence analysis of CLSM images demonstrated that the cured MAE-DB-incorporated sealant could hamper the adherence of S. mutans and exert a detrimental effect on bacterial membrane integrity. The incorporation of MAE-DB can render a pit-and-fissure sealant with contact antibacterial activity after polymerization via influencing the growth, adherence, and membrane

  2. Cane molasses and NaOH teated bagacillo diets for lambs | Chicco ...

    African Journals Online (AJOL)

    Cane molasses and NaOH teated bagacillo diets for lambs. C.F. Chicco, G Garcia, C Fernandez, C.R. Prays. Abstract. The eftect of alkali-treated bag acillo in diets varying in proportion of bagacillo and mollasses was studied in lambs. The bagacillo was treated with a concentration solution of NaOH in a horizontald rum-type ...

  3. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  4. Process for nondestructively testing with radioactive gas using a chill set sealant

    International Nuclear Information System (INIS)

    Gibbons, C.B.

    1975-01-01

    An article surface is nondestructively tested for substantially invisible surface voids by absorbing a radioactive gas thereon. The adsorbed radioactive gas is disproportionately retained on those surfaces presented by the substantially invisible surface voids as compared to the remaining surfaces of the article contacted by the radioactive gas. The radiation released by the radioactive gas remaining adsorbed is used to identify the substantially invisible voids. To immobilize the radioactive gas adjacent or within the surface voids, a sealant composition is provided which is capable of being chill set. The temperatures of the article surface to be tested and the sealant composition are then related so that the article surface is at a temperature below the chill set temperature of the sealant composition and the sealant composition is at a temperature above its chill set temperature. The article portion to be tested is then coated with sealant composition to form a chill set coating thereon of substantially uniform thickness. (U.S.)

  5. Effect of a surface sealant on the color stability of composite resins after immersion in staining solution.

    Science.gov (United States)

    Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão

    2016-01-01

    This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.

  6. The effect of bonding agents on the microleakage of sealant following contamination with saliva

    Directory of Open Access Journals (Sweden)

    Askarizadeh Nahid

    2008-06-01

    Full Text Available Aims : An issue of concern in dentistry is the inadequacy of adhesion and proper sealing following restoration of a tooth, which can lead to marginal leakage. The aim of this study was to evaluate the effect of a bonding agent on the microleakage of a sealant material following contamination with saliva. Materials and Methods : In this experimental research, 48 sound premolars were divided into two groups. The first group received sealant without bonding and the other group was given sealant with bonding. After prophylaxis, the occlusal surfaces were etched with 37% phosphoric acid gel and the teeth were then placed in fresh human saliva for l0 s. Following this, in the first group fissure sealant (Kerr was applied directly and cured; for the second group sealant was placed and cured after bonding (Single Bond; 3M. All samples were thermocycled (500 cycles; between 5°C and 55°C; dwell time of 30 s. Silver nitrate was used as the leakage tracer. The teeth were sectioned. Microleakage evaluation was made by stereomicroscope at 40x magnification and the results were evaluated with the Mann-Whitney U test. Results : In the group that received sealant without bonding extensive microleakage was seen; placement of sealant with bonding significantly reduced microleakage. Conclusion : In the presence of contamination with saliva, use of bonding under the fissure sealant can reduce microleakage

  7. Dental sealant knowledge, opinion, values and practice of Spanish dentists

    Directory of Open Access Journals (Sweden)

    San Martin Laura

    2013-02-01

    Full Text Available Abstract Background Multiple guidelines and systematic reviews recommend sealant use to reduce caries risk. Yet, multiple reports also indicate that sealants are significantly underutilized. This study examined the knowledge, opinions, values, and practice (KOVP of dentists concerning sealant use in the southwest region of Andalusia, Spain. This is a prelude to the generation of a regional plan for improving children’s oral health in Andalusia. Methods The survey’s target population was dentists working in western Andalusia, equally distributed in the provinces of Seville, Cadiz, and Huelva (N=2,047. A convenience sample of meeting participants and meeting participant email lists (N=400 were solicited from the annual course on Community and Pediatric Dentistry. This course is required for all public health sector dentists, and is open to all private sector dentists. Information on the dentist’s KOVP of sealants was collected using four-part questionnaire with 31, 5-point Likert-scaled questions. Results The survey population demographics included 190 men (48% and 206 women (52% with an average clinical experience of 10.6 (± 8.4 years and 9.3 (± 7.5 years, respectively. A significant sex difference was observed in the distribution of place of work (urban/suburb (p=0.001, but no sex differences between working sector (public/private. The mean ± SD values for each of the four KOVP sections for pit and fissure sealants were: knowledge = 3.57 ± 0.47; opinion = 2.48 ± 0.47; value = 2.74 ± 0.52; and practice = 3.48 ± 0.50. No sex differences were found in KOVP (all p >0.4. Independent of sex: knowledge statistically differed by years of experience and place of work; opinion statistically differed by years of experience and sector; and practice statistically differed by years of experience and sector. Less experienced dentists tended to have slightly higher scores (~0.25 on a Likert 1–5 scale. Statistically significant correlations were

  8. Effect of Adhesive Application on Sealant Success: A Clinical Study of Fifth and Seventh Generation Adhesive Systems

    Directory of Open Access Journals (Sweden)

    Vaibhav Tandon

    2016-03-01

    Full Text Available Objectives: The aim of the study was to compare the effect of fifth and seventh generation bonding agent on sealant success.Materials and Methods: Sixty-four school children aged six to nine years received sealants in four permanent molars in a split mouth design, such that each patient received sealant in the first permanent molar with fifth generation bonding agent in one arch and seventh generation bonding agent in the other arch; contra-lateral molars were sealed with sealant alone. The evaluation was carried out at baseline, three months, six months and 12 months, according to the criteria by Feigal et al, in 2000. Chi- square test was used to analyze data at P<0.05 level of significance.Results: Statistically significant differences were found for sealant retention between fifth generation and sealant group, and fifth generation and seventh generation groups; whereas, no significant difference was found for sealant retention between seventh generation and sealant group at three, six and 12 months.Conclusion: As separate etch and rinse steps are not required for seventh generation bonding agents, and almost similar results were obtained for both sealant and seventh generation groups, it can be concluded that application of sealant along with a seventh generation bonding agent may enhance sealant success and can be used for caries prevention in preventive programs.Key words:  Pit and Fissure Sealants; Dental Caries; Adhesives

  9. Marginal leakage of two newer glass-ionomer-based sealant materials assessed using micro-CT.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.; Frencken, J.E.F.M.

    2010-01-01

    OBJECTIVES: To test newer glass-ionomer-based materials as sealant materials. One glass-ionomer sealant was light-cured to obtain an early setting reaction. The null-hypothesis tested was: there is no difference in marginal leakage of sealants produced with high-viscosity glass-ionomer, with and

  10. Unraveling the microbiota of teat apices of clinically healthy lactating dairy cows, with special emphasis on coagulase-negative staphylococci.

    Science.gov (United States)

    Braem, G; De Vliegher, S; Verbist, B; Piessens, V; Van Coillie, E; De Vuyst, L; Leroy, F

    2013-03-01

    Swab samples (n=72) obtained from the teat apex of lactating dairy cows without visual signs of inflammation (n=18) were gathered on 2 well-managed Flemish dairy herds (herds 1 and 2) during the same month to assess the bacterial diversity of teat apices before milking. A combination of both culture-dependent [plating and (GTG)(5)-PCR fingerprinting of the colonies] and culture-independent [denaturing gradient gel electrophoresis (PCR-DGGE)] techniques indicated that the teat apices contain a wide diversity of bacterial genera. Despite a low bacterial load, 20 bacterial genera of 3 phyla (Actinobacteria, Firmicutes, and Proteobacteria) were present. The most prevalent bacteria were the coagulase-negative staphylococci (CNS), encompassing a total of 15 species, which were identified to the species level using a combination of (GTG)(5)-PCR fingerprinting, gene sequencing (16S ribosomal RNA and rpoB genes), and a novel PCR-DGGE technique based on the tuf-PCR amplicon. Overall bacterial diversity did not differ significantly between the herds or between noninfected and subclinically infected quarters in herd 1. In herd 1, borderline significant lower CNS species diversity was found on teat apices of noninfected quarters compared with subclinically infected quarters. The most prevalent CNS species were Staphylococcus haemolyticus and Staphylococcus equorum in both herds and Staphylococcus carnosus in herd 2. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. USE OF HYDROALCOHOLIC EXTRACT OF Schinus terebinthifolius Raddi IN PRE- AND POST-MILKING ANTISEPSIS OF THE TEAT IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Ângela Faccin

    2016-01-01

    Full Text Available Medicinal plants have been used for centuries as an alternative treatment for health problems. Schinus terebinthifolius Raddi is a median tree that belongs to the Anacardiaceae family. The antibacterial effect of leaves extract of this plant has already been demonstrated. The objective of this study was to test a substance derived from this plant to be used in pre- and post-milking teat antisepsis. The hydroalcoholic extract of Brazilian pepper tree was used in opposite quarters for twelve consecutive weeks, and commercial iodine was used as control. None of the indices analyzed – black background mug, CMT, intramammary infections, skin health, and teat health – showed a statistical difference between the treatments, suggesting that the plant extract can be used in pre- and post-milking teat antisepsis, as a substitute for conventional products for herds in an agroecological production system.

  12. Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.

    Science.gov (United States)

    Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena

    2016-10-21

    Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at pdental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.

  13. Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.

    Science.gov (United States)

    Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E

    2012-03-01

    The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.

  14. Effectiveness of two new types of sealants: retention after 2 years

    NARCIS (Netherlands)

    Chen, X.; Du, M.; Fan, M.; Mulder, J.; Huysmans, M.C.; Frencken, J.E.

    2012-01-01

    The hypotheses tested were: survival rate of fully and partially retained glass-carbomer sealants is higher than those of high-viscosity glass-ionomer, with and without energy supplied, and that of resin composite; survival rate of fully and partially retained sealants of high-viscosity

  15. PERBEDAAN TOPICAL FLUORIDE APPLICATION DAN FISSURE SEALANT DALAM MENCEGAH KARIES PADAGIGI MOLAR SATU

    Directory of Open Access Journals (Sweden)

    Pawarti Pawarti

    2017-07-01

    Full Text Available Abstract: Topical Fluoride Application And Fissure Sealant To Prevent Dental Caries Permanent First Molars. Anatomy pits and fissures of teeth are caries initiation vulnerable areas of the permanent molars that grow at the age of 6 years where children can not perform oral hygiene. Caries prevention can be done by closing the pits and fissures or application of fluoride (topical fluoride application on the surface of the teeth. The purpose of this study was to analyze the difference fissure sealants and topical application of fluoride to prevent dental caries of first permanent molars. This study was a quasi-experimental study with time series, a sample was taken by purposive 117-second grade students of SDN District of North Pontianak. Data were analyzed using t-test. The result showed that fissure sealant more effective in caries prevention of first permanent molar than topical fluoride application where there were none caries teeth after and month fissure sealant, 25% sealant partially off and 11% fully off. Teeth that have done fluoride after 6 months of 3.9% of dental caries, the eighth month of 5.4% of dental caries. There was a significant difference between the effectiveness of fissure sealants with topical application of fluoride to prevent dental caries in first permanent molars p-value < 0.05, after 6-month p-value: 0.004 and after 8-month p-value: 0.001. Abstrak: Topical Fluoride Application Dan Fissure Sealant Untuk Mencegah Karies Pada Gigi Molar Satu Permanen. Anatomi pit dan fisura gigi merupakan daerah rentan inisiasi karies gigi molar satu permanen yang tumbuh pada usia 6 tahun anak belum bisa melakukan kebersihan mulutnya. Pencegahan karies dapat dilakukan dengan cara menutup pit dan fissure atau pengolesan fluor (topical fluoride application pada permukaan gigi. Tujuan penelitian ini untuk menganalisis perbedaan efektivitas fissure sealant dan topical fluoride application untuk mencegah karies gigi molar satu permanen anak

  16. The economics of pit and fissure sealants in preventive dentistry: a review.

    Science.gov (United States)

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  17. Self-Healable and Reprocessable Polysulfide Sealants Prepared from Liquid Polysulfide Oligomer and Epoxy Resin.

    Science.gov (United States)

    Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu

    2017-05-10

    Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.

  18. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.

    Science.gov (United States)

    Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L

    2010-05-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    Directory of Open Access Journals (Sweden)

    Han Gyu Cha

    2012-09-01

    Full Text Available Background The most common complication of latissimus dorsi myocutaneous flap in breastreconstruction is seroma formation in the back. Many clinical studies have shown that fibrinsealant reduces seroma formation. We investigated any statistically significant differences inpostoperative drainage and seroma formation when utilizing the fibrin sealant on the site ofthe latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction afterskin-sparing partial mastectomy.Methods A total of 46 patients underwent immediate breast reconstruction utilizing alatissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedurewithout fibrin sealant and the other 23 were administered the fibrin sealant. All flaps wereelevated with manual dissection by the same surgeon and were analyzed to evaluate thepotential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U testwere used for analyzing the drainage volume according to age, weight of the breast specimen,and body mass index.Results Although not statistically significant, the cumulative drainage fluid volume was higherin the control group until postoperative day 2 (530.1 mL compared to 502.3 mL, but thefibrin sealant group showed more drainage beginning on postoperative day 3. The donor sitecomparisons showed the fibrin sealant group had more drainage beginning on postoperativeday 3 and the drain was removed 1 day earlier in the control group.Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Becausethe benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussedwith patients before its use as a part of informed consent.

  20. A review of bioceramics and fibrin sealant.

    Science.gov (United States)

    Le Guéhennec, L; Layrolle, P; Daculsi, G

    2004-09-13

    This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  1. A Review of Bioceramics and Fibrin Sealant

    Directory of Open Access Journals (Sweden)

    Le Guéhennec L.

    2004-09-01

    Full Text Available This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  2. Glass Composition for the use as a Sealant

    DEFF Research Database (Denmark)

    2014-01-01

    The invention concerns a glass composition for the use as a sealant, particularly in a solid oxide fuel cell (SOFC) or in a solid oxide electrolyser cell (SOEC). The glass composition comprises 35-70 mol% CaO, 5-45 mol% ZnO, 5-50 mol% B2O3, 1-45 mol% SiO2, and 1 mol% or less of each element...... of the group, comprising Ba, Na and Sr, based on the total glass composition. Furthermore, the invention relates to an SOFC and an SOEC employing a sealant of said glass composition....

  3. Treatment of venous ulcers with fibrin sealant derived from snake venom

    Directory of Open Access Journals (Sweden)

    MAN Gatti

    2011-01-01

    Full Text Available Venous ulcers of the lower limbs complicated by infection or chronicity represent a serious public health problem. The elevated number of those afflicted burdens the health services, interferes in quality of life and causes absenteeism. Although there are 2,500 items on the market, ranging from the simplest dressing up to the most complex types of dressing, treatment remains a challenge. Among the substances used, fibrin sealant is the one that promotes diminution of bacterial colonization and of edema, controls hemorrhaging, alters the pain threshold by protecting the nerve endings, hydrates the wound bed and forms granulation tissue that favors healing. Its disadvantages include higher cost and utilization of human fibrinogen that can transmit infectious diseases. The Center for the Study of Venoms and Venomous Animals (CEVAP at São Paulo State University (UNESP developed a new sealant made up of fibrinogen extracted from large animals and from an enzyme obtained from snake venom. The present study, developed in the Health Education Clinic (CEPS of Sacred Heart University (USC aimed to evaluate the effect of the new sealant on the healing process of venous ulcers in 24 adult patients, seven of whom were male and 17 female. Two study groups were formed as follows: Group 1 (G1 - control group of 11 patients treated with essential fatty acid (EFA and Unna's boot, and Group 2 (G2 - 13 patients treated with essential fatty acid (EFA, fibrin sealant and Unna's boot. The follow-up lasted eight weeks and the sealant was applied at only the first and fourth weeks. The results showed that Group 2 presented worse lesion conditions as to healing, but, when comparing the two groups, it was noteworthy that the the sealant was effective in healing venous ulcers. There is evidence that the new sealant is recommended for leg ulcers with the following advantages: ease of application, preparation of the wound bed, diminution of pain and a higher number of

  4. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  5. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    Science.gov (United States)

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  6. PAH volatilization following application of coal-tar-based pavement sealant

    Science.gov (United States)

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.

  7. 76 FR 59087 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-09-23

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental... manufacture, sale, use, or application of adhesives, sealants, primers, and solvents. This action is being... consists of Delaware's regulation for reducing VOCs from commercially-used adhesive and sealant products by...

  8. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  9. Estimating emissions from adhesives and sealants uses and manufacturing for environmental risk assessments.

    Science.gov (United States)

    Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten

    2016-01-01

    Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry

  10. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    Science.gov (United States)

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  11. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  12. Caries detection methods : Can they aid decision making for invasive sealant treatment?

    NARCIS (Netherlands)

    Pereira, AC; Verdonschot, EH; Huysmans, M

    2001-01-01

    The decision to place sealants is a difficult one, and it has been suggested that in a low risk population it may be efficient to wait until caries is detected in the fissure. An invasive sealant technique with fissure preparation may then be indicated. The diagnostic method used in the indication

  13. Microtensile Bond Strength of Embrace Wetbond Hydrophilic Sealant in Different Moisture Contamination: An In-Vitro Study.

    Science.gov (United States)

    Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti

    2015-07-01

    Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.

  14. Survival of sealants in molars affected by molar-incisor hypomineralization: 18-month follow-up

    Directory of Open Access Journals (Sweden)

    Camila Maria Bullio FRAGELLI

    2017-04-01

    Full Text Available Abstract The objective of this study was to evaluate the clinical survival of sealants applied in first permanent molars (FPMs affected by molar-incisor hypomineralization (MIH, at 18 months of follow-up. Forty-one first permanent molars were selected from 21 children, 6–8 years of age. MIH was classified by one calibrated examiner (kappa = 0.80 according to EAPD criteria. The inclusion criteria were fully erupted FPMs with MIH or sound FPMs (without MIH for which sealant treatment was indicated. The FPMs were assigned to two groups: CG (control group and HG (MIH group. Both groups were treated with sealant (FluroShield. Clinical follow-up was performed from baseline to 18 months to assess anatomical form, marginal adaptation, retention and presence of caries, according to criteria set by the United States Public Health Service-Modified, and was conducted by a blinded examiner (kappa = 0.80. The actuarial method was used to evaluate the survival of the sealants. The survival rates for the groups were compared using Fisher’s exact test (α = 5%. The cumulative survival rates were 81% at 1 month, 68.8% at 6 months, 68.8% at 12 months, and 62.6% at 18 months for CG, and 88% at 1 month, 84% at 6 months, 76% at 12 months, and 72% at 18 months for HG. No significant difference was found between the groups. The sealants in molars affected by MIH presented a survival rate similar to the sealants in the control, suggesting that sealants may be an adequate approach for preventing carious lesions in MIH-affected molars.

  15. Microleakage, adaptation ability and clinical efficacy of two fluoride releasing fissure sealants

    Directory of Open Access Journals (Sweden)

    Marković Dejan

    2012-01-01

    Full Text Available Background/Aim. Retention of fissure sealants and good adaptation to enamel are essential for their success. Fluoride releasing resin-based materials are widely accepted for pit and fissure sealing, but newly designed glass ionomers can serve as a good alternative. The aim of this study was to evaluate microleakage and sealing ability in vitro, and to clinically assess two fluoride releasing fissure sealants. Methods. The sample for experimental study consisted of 20 freshly extracted intact human third molars, divided in two experimental groups according to the sealing material: fluoride releasing resin-based (Heliosel F and glass ionomer (Fuji Triage material. Digital images and scanning electron microscope were used to assess microleakage and adaptation ability. Sample for clinical study consisted of 60 children, aged 6-8 years, with high caries risk, divided in two groups according to the sealant material. Fissure sealant was applied to all erupted, caries-free first permanent molars. Sealants were evaluated after 3, 6 and 12 months using modified Ryge criteria for retention, marginal adaptation, colour match, surface smoothness and caries. Results. Microleakage was detected in more than half of the specimen, without significant differences between the two groups (p > 0.05. Both materials exhibited acceptable sealing ability. Complete retention at the end of the observation period was 81.8% for resin-based, and 21.1% for glass-ionomer fissure sealant (p < 0.001. The presence of caries in sealed molars has been detected in one patient in both groups. During the 12-month observation period, Helioseal F demonstrated better retention, marginal adaptation and surface smoothness (p < 0.001. There were no differences between the two materials regarding caries and color match (p > 0.05. Conclusion. Both tested materials demonstrate satisfactory clinical and caries prophylactic characteristics that justify their use in contemporary preventive

  16. Comparison of various concentrations of tricalcium phosphate nanoparticles on mechanical properties and remineralization of fissure sealants.

    Directory of Open Access Journals (Sweden)

    Sara Tavassoli-Hojjati

    2014-08-01

    Full Text Available The aim of this study was to investigate the mechanical properties (flexural strength, micro-shear bond strength and remineralizing potential of fissure sealants by adding various concentrations of β-tricalcium phosphate nanoparticles.This in-vitro study consisted of five experimental groups containing prepared nano-fisssure sealants (1-5 wt.% β-TCP nanoparticles and two control groups containing a prepared and a commercial fissure sealant. Flexural/micro-shear bond strength values were measured using Zwick test machine. Cavities on sixty healthy premolar teeth were filled with the fissure sealants containing 0-5 wt.% of nano β-TCP. The samples were assessed for remineralization under scanning electron microscopy (SEM and EDAX. Kolmogorov-Smirnov test, One-way ANOVA and Tukey's Post Hoc analysis/HSD were used to analyze the data.There was no significant difference between the flexural strengths/elastic modulus of the 0-5 wt.% nano β-TCP groups (p>0.05. The average flexural strength/elastic modulus of the prepared fissure sealant group (0% was significantly higher than the commercial fissure sealant group (Clinpro (p0.05. Examining the samples under SEM showed a significant increase in thickness of the intermediate layer with increasing concentrations of β-TCP nanoparticles (p<0.05.Addition of 1-5 wt.% β-TCP nanoparticles to the fissure sealants significantly increased the remineralization potential without affecting the mechanical properties.

  17. Safety and usability of hemostats, sealants, and adhesives.

    Science.gov (United States)

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  18. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    Science.gov (United States)

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  19. Clinical and SEM assessment of ART high-viscosity glass-ionomer sealants after 8-13 years in 4 teeth.

    NARCIS (Netherlands)

    Frencken, J.E.F.M.; Wolke, J.G.C.

    2010-01-01

    OBJECTIVES: Resin composite sealants are retained longer than low-viscosity glass-ionomer sealants. Nevertheless, a systematic review showed that there is no evidence that resin composite sealants are superior to low-viscosity glass-ionomers in preventing dentine carious lesion development. This

  20. Causes of poor sealant performance in soil-gas-resistant foundations

    International Nuclear Information System (INIS)

    Scott, A.

    1994-01-01

    Sealants for radon-resistant foundation construction must seal the gap between concrete sections. Modern sealants have such low permeability that seal performance depends only on the permeability of the material that contacts the sealant. The surface permeability of concrete walls and floors was measured by a specially designed permeameter, which measures the airflow induced by a pressure difference across a temporary test seal applied to the surface. The permeability of bulk concrete is about 10 -15 m 2 . Areas free of surface defects had surface permeability ranging from 10 -14 to 10 -16 m 2 . However, surface defects are common on concrete wall surfaces, which increase the permeability to >10 -12 m 2 , too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Radon-resistant seals require either extended contact widths or mechanical removal of the surface layer and defects. (au) (4 refs.)

  1. Bisphenol A in dental sealants and its estrogen like effect

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2012-01-01

    Full Text Available Bisphenol A or BPA-based epoxy resins are widely used in the manufacture of commercial products, including dental resins, polycarbonate plastics, and the inner coating of food cans. BPA is a precursor to the resin monomer Bis-GMA. During the manufacturing process of Bis-GMA dental sealants, Bisphenol A (BPA might be present as an impurity or as a degradation product of Bis-DMA through esterases present in saliva. Leaching of these monomers from resins can occur during the initial setting period and in conjunction with fluid sorption and desorption over time and this chemical leach from dental sealants may be bioactive. Researchers found an estrogenic effect with BPA, Bis-DMA, and Bis-GMA because BPA lacks structural specificity as a natural ligand to the estrogen receptor. It generated considerable concern regarding the safety of dental resin materials. This review focuses on the BPA in dental sealants and its estrogen-like effect.

  2. Low-cost glass ionomer cement as ART sealant in permanent molars: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Daniela HESSE

    2015-01-01

    Full Text Available Clinical trials are normally performed with well-known brands of glass ionomer cement (GIC, but the cost of these materials is high for public healthcare in less-affluent communities. Given the need to research cheaper materials, it seems pertinent to investigate the retention rate of a low-cost GIC applied as atraumatic restorative treatment (ART sealants in two centers in Brazil. Four hundred and thirty-seven 6-to-8-year-old schoolchildren were selected in two cities in Brazil. The children were randomly divided into two groups, according to the tested GIC applied in the first permanent molars. The retention rate was evaluated after 3, 6 and 12 months. Kaplan-Meier survival analysis and the log-rank test were performed. The variables were tested for association with sealant longevity, using logistic regression analyses (α = 5%. The retention rate of sealants after 12 months was 19.1%. The high-cost GIC brand presented a 2-fold-more-likely-to-survive rate than the low-cost brand (p < 0.001. Significant difference was also found between the cities where the treatments were performed, in that Barueri presented a higher sealant survival rate than Recife (p < 0.001. The retention rate of a low-cost GIC sealant brand was markedly lower than that of a well-known GIC sealant brand.

  3. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    Science.gov (United States)

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  4. Percutaneous treatment of femoral pseudoaneurysms: comparison of fibrin sealant against thrombin

    Directory of Open Access Journals (Sweden)

    Daniel Mendes Pinto

    2013-12-01

    Full Text Available INTRODUCTION: Femoral pseudoaneurysms are a complication that occurs in connection with up to 8% of percutaneous procedures. Of the available treatments, ultrasound guided thrombin injection has a high success rate and is well-tolerated by patients. The combination of thrombin and fibrinogen known as fibrin sealant forms a stable clot and can be used to treat pseudoaneurysms, particularly those with complex anatomy and larger size. OBJECTIVE: To compare the results of treating femoral pseudoaneurysm in two ways: Group T was treated with thrombin alone and Group T+F was treated with fibrin sealant (thrombin+fibrinogen. METHODS: A retrospective analysis was conducted of femoral pseudoaneurysm cases treated between January 2005 and December 2012. RESULTS: Twenty-eight patients were treated, 21 with thrombin alone and seven with fibrin sealant. All patients in group T were treated successfully, but only four patients in group T+F were treated successfully (57.1% success rate in Group T+F, p<0.01. The three cases of failure in group T+F needed surgery and in one of these cases the complication was embolization to the femoral bifurcation. The pseudoaneurysms that were treated with fibrin sealant were larger (25 cm3 in Group T and 57.7 cm3 in Group T+F, p=0.02 and required larger volumes of thrombin (0.5 mL in Group T and 1.0 mL in Group T+F, p<0.01. There was one complication in Group T and two complications in Group T+F (p<0.01. CONCLUSIONS: Irrespective of the small number of cases reviewed, treatment with thrombin alone was superior to treating with fibrin sealant, since it caused few complications and was more effective at correcting pseudoaneurysms.

  5. A Trajectory Generation Method Based on Edge Detection for Auto-Sealant Cartesian Robot

    Directory of Open Access Journals (Sweden)

    Eka Samsul Maarif

    2014-07-01

    Full Text Available This paper presents algorithm ingenerating trajectory for sealant process using captured image. Cartesian robot as auto-sealant in manufacturing process has increased productivity, reduces human error and saves time. But, different sealant path in many engine models means not only different trajectory but also different program. Therefore robot with detection ability to generate its own trajectory is needed. This paper describes best lighting technique in capturing image and applies edge detection in trajectory generation as the solution. The algorithm comprises image capturing, Canny edge detection, integral projection in localizing outer most edge, scanning coordinates, and generating vector direction codes. The experiment results show that the best technique is diffuse lighting at 10 Cd. The developed method gives connected point to point trajectory which forms sealant path with a point to next point distance is equal to 90° motor rotation. Directional movement for point to point trajectory is controlled by generated codes which are ready to be sent by serial communication to robot controller as instruction for motors which actuate axes X and Y directions.

  6. An accelerated exposure and testing apparatus for building joint sealants.

    Science.gov (United States)

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  7. Effectiveness of a new gelatin sealant system for dural closure.

    Science.gov (United States)

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P control group (13·8 ± 4·0 mmHg, P control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  8. Comparative efficacy of nanofilled and microfilled resin-modified glass ionomer as pits and fissure sealant in permanent molar teeth

    Directory of Open Access Journals (Sweden)

    Manzuma Akhter Zakaria

    2017-05-01

    Full Text Available The purpose of the present study was to compare the efficacy of nanofilled and microfilled resin- modified glass ionomer as pits and fissure sealants in permanent molar teeth. Ninety six teeth having fissure at the occlusal surface were randomly divided into two groups: Group I: Treated by nanofilled resin-modified glass ionomer sealant and Group II: Treated by microfilled resin- modified glass ionomer sealants. Clinical assessment was performed by modified Ryge´s criteria by means of retention, color match, marginal adaptation at 3, 6, and 12 months follow-up visit. Chi-square test was used for testing differences between the two groups; a value of p<0.05 was considered as statistically significant. The results revealed that at 12 months observation period, nanofilled resin-modified glass ionomer sealant showed better retention, color stability and marginal adaptation than that of microfilled resin-modified glass ionomer sealants. Furthermore, the differences between two groups in respect to marginal adaptation and color match were statistically significant (p<0.05. It can be concluded that nanofilled resin-modified glass ionomer sealant could be a better alternative to microfilled resin- modified glass ionomer sealant.

  9. [Correlations between the vitality of newborn piglets, teat order, mortality, and live weight development up to weaning].

    Science.gov (United States)

    Hoy, S; Lutter, C; Puppe, B; Wähner, M

    1995-06-01

    Investigations with 693 piglets have shown, that suckling piglets with preference of cranial teat pairs were significantly superior to their littermates in all parameters of early postnatal vitality: they stood up and took in first colostrum earlier and showed a lower postnatal drop in rectal temperature in comparison with their siblings. Piglets in cranial teat position had the highest daily gain (205 g, p vitality of piglets post natum on live weight development and mortality up to 28th day of age were shown. The faster piglets took in colostrum after birth and the lower postnatal drop in rectal temperature was, the higher was the obtained daily gain during suckling period. Piglets which died within the first 7 or 28 days of age had needed a significantly longer time till first postnatal colostrum intake and a more pronounced drop in rectal temperature in comparison with their littermates.

  10. Antibacterial activities of coagulase-negative staphylococci from bovine teat apex skin and their inhibitory effect on mastitis-related pathogens.

    Science.gov (United States)

    Braem, G; Stijlemans, B; Van Haken, W; De Vliegher, S; De Vuyst, L; Leroy, F

    2014-05-01

    To explore antibacterial activities of coagulase-negative staphylococci (CoNS) from teat apices of dairy cows towards mastitis-causing pathogens. Of 254 CoNS, 38 displayed bacteriocin-like activity after a first screening. Seven of these strains displayed activity against at least one mastitis-related pathogen (Streptococcus uberis, Streptococcus dysgalactiae and Staphylococcus aureus). Staphylococcus chromogenes L217 displayed the strongest inhibitory effect, being active against all tested mastitis-related pathogens and most tested CoNS. Based on cation exchange and reversed-phase chromatography, in addition to N-terminal Edman degradation and PCR, the antibacterial peptide was identified as a nukacin-type bacteriocin and named nukacin L217. Although staphylococcal bacteriocins are generally found in the cell-free supernatants of liquid cultures, Staph. chromogenes L217 only led to detectable activity when grown on agar medium. Bacteriocin-like activities are not uncommon among CoNS from teat apices and may inhibit mastitis-causing pathogens, as found for nukacin L217 production by Staph. chromogenes L217. Nukacin L217 is the first identified bacteriocin of the species Staph. chromogenes and displays unusual production kinetics, that is, requiring surface growth of its producer. The fact that nukacins are produced by different CoNS species suggests a role in the teat skin ecosystem. © 2014 The Society for Applied Microbiology.

  11. Microleakage assessment of fissure sealant following fissurotomy bur or pumice prophylaxis use before etching

    Directory of Open Access Journals (Sweden)

    Ali Bagherian

    2013-01-01

    The aim of this investigation was to compare the microleakage level of fissure sealants prepared by a fissurotomy bur or pumice prophylaxis prior to acid etching. Materials and Methods: Ninety freshly extracted healthy maxillary premolar teeth were randomly selected for this investigation. Teeth were then divided into three fissure sealant preparatory groups of A: Fissurotomy bur + acid etch; B: Pumice prophylaxis + acid etch and C: Acid etch alone. Sealant was applied to the occlusal fissures of all specimens using a plastic instrument. This was to avoid any air trap under the sealant. Sample teeth were first thermocycled (1000 cycles, 20 s dwell time and then coated with two layers of nail varnish leaving 2 mm around the sealant. This was then followed by immersion in basic fuchsin 3%. Processed teeth were sectioned longitudinally and examined under a stereomicroscope for microleakage assessment using a score of 0-3. Collected data was then subjected to Kruskall-Wallis Analysis of Variance and Mann-Whitney U-test. P < 0.05 was considered as significant. Results: Teeth in fissurotomy bur and pumice prophylaxis groups had significantly reduced level of microleakage than those in acid etch alone (P = 0.005 and P = 0.003, respectively. Conclusion: Use of fissurotomy bur and pumice prophylaxis accompanied with acid etching appears to have a more successful reduction of microleakage than acid etch alone.

  12. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    Science.gov (United States)

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  13. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    Science.gov (United States)

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  14. Use of fibrin sealants for the localized, controlled release of cefazolin

    Science.gov (United States)

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  15. Efficacy of a high free iodine barrier teat disinfectant for the prevention of naturally occurring new intramammary infections and clinical mastitis in dairy cows.

    Science.gov (United States)

    Martins, C M M R; Pinheiro, E S C; Gentilini, M; Benavides, M Lopez; Santos, M V

    2017-05-01

    Using a natural exposure trial design, the goal of our study was to evaluate the clinical efficacy of an iodine teat disinfectant with barrier properties and a high level of free iodine relative to a conventional iodine teat disinfectant with no barrier properties and low levels of free iodine. During the 18 wk of the trial, quarter milk samples were collected every 2 wk from 385 dairy cows from 2 herds. Cows on both farms were assigned in a balanced way according to milk yield, number of lactation, days in milk, somatic cell count (SCC) and microbiology culture pretrial into one of following groups: nonbarrier post milking teat disinfectant (NBAR; n = 195 cows; 747 quarters) or barrier postmilking teat disinfectant (BAR; n = 190 cows; 728 quarters). Afterward, at each scoring date every 2 wk, milk SCC was quantified in samples from all mammary quarters and microbiologic culture was only performed on milk samples with SCC >200,000 cells/mL for multiparous cows and SCC >100,000 cells/mL for primiparous cows. A new intramammary infection (NIMI) was defined when a quarter had milk SCC 200,000 cells/mL for multiparous cows and >100,000 cells/mL for primiparous cows, and positive microorganism isolation. A quarter could have several NIMI, but only 1 case per specific pathogen was considered. The most frequently isolated microorganism group on both farms was Streptococcus spp. (6.25% of total mammary quarters), followed by coagulase-negative staphylococci (3.6%) and Corynebacterium spp. (1.5%). In the present study, an interaction occurred between treatment and week of trial on the incidence risk of NIMI. Quarters disinfected with BAR had 54 and 37% lower odds of NIMI than quarters disinfected with NBAR at 8 and 16 wk of the trial, respectively; whereas at other weeks of the study both products had similar incidence risks of NIMI. Overall, teats disinfected with BAR had 46% lower odds of acquiring a clinical mastitis than those disinfected with NBAR. We concluded that

  16. Comparison of a plasma-based composite biologic sealant with fibrin glue (Tisseel) for vascular anastomoses.

    Science.gov (United States)

    Doillon, Charles J; Dion, Yves-Marie

    2004-12-01

    Biologic sealants are needed in numerous, more and more demanding, procedures--especially with developments occurring in endovascular and laparoscopic vascular techniques. An initial pilot study in dogs showed that a 4-cm aortotomy closed with a polyester patch sutured in place by a 4-mm-spaced running suture consistently led to massive hemorrhage. We then designed a study using five dogs where two aortotomies were done to compare the effect of Tisseel to that of an autologous sealant prepared in our laboratory. Arterial pressures and heparinization were maintained throughout the surgical procedure. Both biologic sealants prevented hemorrhage from the arteriotomy at unclamping. Macroscopic and histologic assessments were performed. At killing, one week later, the autologous sealant exhibited less blood saturation of the collagen sponge compared with Tisseel. The use of autologous plasma combined with other adhesive components could be an efficient alternative to allogenic fibrin glue. Further studies are needed to confirm these observations.

  17. 76 FR 79537 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-12-22

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental..., sale, use, or application of adhesives, sealants, primers, and solvents. EPA is approving this SIP... miscellaneous industrial adhesives control techniques guideline (CTG) category in accordance with the...

  18. Communications of Staphylococcus aureus and non-aureus Staphylococcus species from bovine intramammary infections and teat apex colonization

    DEFF Research Database (Denmark)

    Mahmmod, Yasser S.; Klaas, Ilka Christine; Svennesen, Line

    2018-01-01

    The role of non-aureus staphylococci (NAS) in the risk of acquisition of intramammary infections with Staphylococcus aureus is vague and still under debate. The objectives of this study were to (1) investigate the distribution patterns of NAS species from milk and teat skin in dairy herds with au...

  19. The influence of milking procedures on cow’s teat tissue, milk yield and milking time

    Directory of Open Access Journals (Sweden)

    Saša Špoljar

    2004-04-01

    Full Text Available The aim of this study was to evaluate the effect of two different milking procedures on teat length and diameter, milk yield and milking time. During the first milking procedure the milker decides when to remove the milking cluster from the udder, while in the second an automatic cluster removal, when milk flow was lower than 200 g/min, was performed. Measurements were made on two commercial farms B and A on 15 randomly chosen cows without any clinical sign of mastitis. There were no significant differencesbetween those farms in teat length and diameter differences before and after the milking. Average milking time on farm A was 6 min and 58 s, while on farm B was 5 min and 3 s. Average milk yield was 12.9 kg on farm B and 13.4 kg on farm A. Milking time was considerably shorter on farm B compared to farm A, while milk yield was almost equal on both farms. Automatic cluster weighting 2 kg removal was performed when milk flow was lower than 200 g/min in order to shorten the time needed to milk the cow, ensuring good udder health.

  20. ART restorations and sealants placed in Chinese school children--results after three years.

    Science.gov (United States)

    Holmgren, C J; Lo, E C; Hu, D; Wan, H

    2000-08-01

    These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.

  1. Polychlorinated biphenyls in polysulfide sealants-Occurrence and emission from a landfill station

    International Nuclear Information System (INIS)

    Persson, N. Johan; Pettersen, Harald; Ishaq, Rasha; Axelman, Johan; Bandh, Cecilia; Broman, Dag; Zebuehr, Yngve; Hammar, Tommy

    2005-01-01

    Approximately 80 000 kg polysulfide sealant containing 10 000-18 000 kg polychlorinated biphenyls (PCB) was deposited at a Swedish municipal landfill station during 1965-1973. Investigations during 1994 showed that soil layers underneath the landfill had concentration of PCB not alarmingly high. The concentration of PCB congeners in ground water samples was elevated 4-750 times compared to a reference sample. Based on samples of ground water, leachate water, and flux chambers measuring evaporation of PCB from the landfill surface, the emission of PCB was estimated to be 1 g ΣPCB/yr. This very low rate was attributed to the high sorptive capacity of the sealant. Compared to a reference site, the evaporation flux was elevated for the most volatile congeners, but factors 20-1400 lower than from another landfill which was contaminated with PCB in paper-pulp fibres. - From a municipal 2-ha landfill containing 10-18 tonnes of ΣPCB bound in polysulfide sealants, only 1 g per year escape to the surroundings

  2. Comparison of commercial fibrin sealants in facelift surgery: a prospective study

    Directory of Open Access Journals (Sweden)

    Botti G

    2013-11-01

    Full Text Available Giovanni Botti,1 Michele Pascali,2 Chiara Botti,1 Florian Bodog,3 Pietro Gentile,2 Valerio Cervelli2 1Villa Bella Clinic, Salò, 2Department of Plastic and Reconstructive Surgery, University of Rome Tor Vergata, Italy; 3University of Oradea, Oradea, Romania Background: The aim of this study was to compare the effects of two types of fibrin glue in patients undergoing facelift surgery. Methods: A prospective, controlled "right-left side" study was carried out in 20 patients. The two fibrin sealants used were Quixil® and Tissucol®. The two sealants were used at the same time, ie, one on one side of the face and the other on the contralateral side. Comparisons were made with regard to rates of hematoma and seroma, degree of induration, edema, ecchymosis, pain levels, and patient satisfaction. Results: The results were almost equivalent. The only exception was a significant (40 mL hematoma in a patient treated with Quixil. Bleeding was most likely due to a sudden rise in blood pressure during the immediate postoperative period. However, it must be emphasized that, while Tissucol actually seals the undermined area, thus virtually eliminating the dead space, Quixil acts differently, in that its effectiveness in preventing hematoma is linked mainly to its hemostatic effect. Conclusion: The two fibrin sealants used were nearly identical with regard to patient safety and quality of the result. Nevertheless, it is noted that, while Tissucol has both hemostatic and "gluing" effects, Quixil is mainly effective in securing hemostasis. Keywords: facelift surgery, rhytidectomy, fibrin sealants, hematoma

  3. Leak tight sealants and joint details for concrete structure in RAPP

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Baste, M.S.

    1975-01-01

    Leak tightness may pertain to either air or water and in extreme cases each will require separate consideration based on general basic requirements. Leak-tight sealants against air pressure are required in the construction joints and around penetrations in the concrete containment structures. The containment structures should be able to withstand the maximum anticipated design pressure during the incident of a MCA with only minimal leakage (0.1% of bldg. volume per day in RAPP) which is mostly through these joints. Apart from proper joint design and preparation the sealant itself must have superb adhesion to the concrete surface and integrify throughout its service life to prevent any rupture or micro-cracks at any section of the joint. Leak tightness pertains to water tightness as well. A critical water-tight joint at the bottom dome of the prestressed concrete dousing tank at its junction with the 36 inches dia dousing water pipes constructed in RAPP-2, which should be able to withstand the water pressure, continuous submergence in the water of the tank and the longitudinal and lateral movement of the water pipes during opening and closure of the dousing valves, has been made and hydrostatically tested when not even the slight sweating was found. The construction and materials of the above joints and the sealant along with the properties and performance observed during testing/use are described. As the sealant used is an imported poly-sulphide caulking compound suggestions have also been made, which may be kept in mind while developing an Indian substitute. (author)

  4. 76 FR 64237 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-10-18

    ...-9480-5] Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants... chemical production and polytetrafluoroethylene operations; from paint, resin, and adhesive manufacturing; and from adhesive and sealant application. This SIP revision also pertains to an addition of a new...

  5. A reversible thermoresponsive sealant for temporary closure of ocular trauma.

    Science.gov (United States)

    Bayat, Niki; Zhang, Yi; Falabella, Paulo; Menefee, Roby; Whalen, John J; Humayun, Mark S; Thompson, Mark E

    2017-12-06

    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N -isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  6. Polychlorinated biphenyls (PCBs) in indoor air originating from sealants in contaminated and uncontaminated apartments within the same housing estate

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Meyer, Harald William; Ebbehøj, Niels Erik

    2012-01-01

    . The PCB(tot) levels in the air of the contaminated section were 168-3843 ng m(-3) (mean: 1030 ng m(-3)), while the mean levels in the reference apartments were 6.03 ng m(-3). The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221680 mg kg(-1). Principal component......Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate...... analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e...

  7. Meta-analysis of dry cow management for dairy cattle. Part 1. Protection against new intramammary infections.

    Science.gov (United States)

    Halasa, T; Osterås, O; Hogeveen, H; van Werven, T; Nielen, M

    2009-07-01

    The objective of this study was to estimate the preventive effect of various dry cow management measures against quarter new intramammary infections (IMI) during the dry period up to 21 d postcalving. Moreover, the potential publication bias was assessed in the studies selected for this analysis. The intervention measures were blanket dry cow therapy (BDCT), selective dry cow therapy (SDCT), cloxacillin compared with other dry cow therapy products, and teat sealant. A meta-analysis relative risk (RR) was calculated per intervention and pathogen group when enough studies were available from the 33 selected studies. Results of the meta-analyses were examined using publication bias tests. Blanket dry cow therapy showed significant protection against new IMI caused by Streptococcus spp. [the pooled RR was 0.39 (0.30 to 0.51)] but no protection was observed against coliform new IMI [the pooled RR was 0.95 (0.81 to 1.10)]. After correction for publication bias, it became doubtful whether DCT is protective against new Staphylococcus spp. IMI. Cloxacillin showed similar protection against new quarter IMI compared with other DCT products [the pooled RR was 1.09 (0.94 to 1.25)]. Selective dry cow therapy showed higher protection against new IMI compared with no DCT [the pooled RR was 0.51 (0.30 to 0.86)]. However, BDCT showed more protection when compared with SDCT [the pooled RR was 0.55 (0.37 to 0.80)], but the inference about whether BDCT is superior to SDCT was dependent on whether the selection criteria for SDCT was at the cow or quarter level. Internal teat sealants showed significant protection against new IMI during the dry period [the pooled RR was 0.39 (0.18 to 0.82)]. Publication bias should be taken into account when attempts are made to review literature in a meta-analysis.

  8. Distribution of CNS Species on Teat Skin and in Milk Samples from Dairy Cows in Automatic Milking Systems

    DEFF Research Database (Denmark)

    Mahmmod, Yasser; Svennesen, Line; Pedersen, Karl

    identified in milk samples. Staphylococcus chromogenes was detected in both milk (n= 2) and teat skin (n= 1) samples. Data collection will be finished in April 2017. The final results will give new insights into herd specific CNS species patterns and the microbial ecology and epidemiology of common CNS...

  9. Short communication: quantification of the transmission of microorganisms to milk via dirt attached to the exterior of teats

    NARCIS (Netherlands)

    Vissers, M.M.M.; Driehuis, F.; Giffel, M.C.T.; Jong, de P.; Lankveld, J.M.G.

    2007-01-01

    Pathogens and spoilage microorganisms can be transmitted to milk via dirt (e.g., feces, bedding material, soil, or a combination of these) attached to the exterior of the cows¿ teats. To determine the relevance of this pathway and to perform quantitative microbial risk analysis of the microbial

  10. Fibrin sealant for mesh fixation in laparoscopic groin hernia repair does not increase long-term recurrence

    DEFF Research Database (Denmark)

    Fenger, Andreas Qwist; Helvind, Neel Maria; Pommergaard, Hans-Christian

    2016-01-01

    BACKGROUND: Methods of groin hernia repair include laparoscopic techniques using tissue-penetrating mesh fixation or non-penetrating fixation. Concerns regarding hernia repair include postoperative chronic pain, sexual dysfunction, and recurrence. Earlier estimations of recurrence rates have......) laparoscopic groin hernia repair using either fibrin sealant or tacks for mesh fixation. METHODS: This study used data from the Danish Hernia Database to create the following cohort: All patients operated laparoscopically for primary groin hernia with a TAPP procedure using fibrin sealant for mesh fixation...... difference in long-term reoperation rates and clinical recurrences in patients undergoing TAPP repair with meshes fixated with fibrin sealant compared with tacks....

  11. Migration of PCBs from Sealants to Adjacent Material

    DEFF Research Database (Denmark)

    Andersen, Helle Vibeke; Gunnarsen, Lars Bo; Kampmann, Kristoffer

    2015-01-01

    PCB in sealants can migrate into porous surfaces like concrete and brick and contaminate these materials. The study focuses on an analysis of concentration profiles in relation to alleviation of PCB contamination. The PCB content was determined in 20 samples of concrete and 6 samples of brick adj...

  12. Clinical Evaluation of applying a hydrophobic and a hydrophilic bonding agent on the retention and durability of fissure sealant therapy

    Directory of Open Access Journals (Sweden)

    Mostafa GHandi

    2016-03-01

    Full Text Available Background and Aims: As in fissure sealant therapy the tooth surface is mostly enamel, the use of an enamel bonding agent (hydrophobic bonding agent may be more cost effective than that of newer generations of bonding (hydrophilic bonding agents. The aim of this study was to compare the retention and durability of fissure sealant therapy when applying an enamel bonding agent, a dentin bonding agent and no bonding agent during 4 years. Materials and Methods: This study was done on the first permanent molars of the upper and lower jaws of 24 students of the first grade of a primary school (6-7 years old. On 36 teeth, a dentin bonding agent (Excite was applied under the fissure sealant and on 36 teeth an enamel bonding agent (Margin bond was applied under the fissure sealant. Then, 24 teeth were selected from these two groups and were compared with a group (including 24 teeth with no bonding agent under the fissure sealant (as control group. All the fissures of the teeth were evaluated annually for 4 years to find out the presence or absence of fissure sealant substance. Data were analyzed using Wilcoxon test. Results: From the statistical analysis, there was no significant difference in retention and durability of the fissure sealant substance comparing the group with dentin bonding agent (Excite and the group with enamel bonding agent (Margin bond. Also, using a bonding agent made no significant difference (P>0.05. Conclusion: According to the results of this study, using a bonding agent made no improvement in the retention and durability of fissure sealant substance.

  13. Evaluation of a hydrophilic gingival dental sealant in beagle dogs.

    Science.gov (United States)

    Sitzman, Clarence

    2013-01-01

    A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p periodontal disease in dogs.

  14. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases.

    Science.gov (United States)

    Siman, Homayoun; Techy, Fernando

    2016-02-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.

  15. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    Science.gov (United States)

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  16. Dental Sealants: Knowledge, Value, Opinion, and Practice among Dental Professionals of Bathinda City, India

    OpenAIRE

    Asawa, Kailash; Gupta, Vivek V.; Tak, Mridula; Nagarajappa, Ramesh; Chaturvedi, Pulkit; Bapat, Salil; Mishra, Prashant; Roy, Santanu Sen

    2014-01-01

    Objective. The purpose of the study was to assess the knowledge, value, opinion, and practice regarding use of dental sealants among private dental practitioners in Bathinda City, Punjab, India. Materials and Methods. A cross-sectional survey was conducted among all private dental practitioners in Bathinda City, Punjab. A self-administered structured questionnaire consisting of 28 items was used to assess their knowledge, value, opinion, and practice regarding dental sealants. One-way analysi...

  17. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    Science.gov (United States)

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  18. Evaluating cyclic fatigue of sealants during outdoor testing

    Science.gov (United States)

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2009-01-01

    A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...

  19. In Vitro Comparison of Microleakage of Two Materials Used as Pit and Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Zahra Bahrololoomi

    2011-09-01

    Full Text Available Background and aims. Marginal seal of the material is extremely important in fissure sealant therapy. The aim of this study was to investigate microleakage of flowable composite resins and conventional fissure sealants with or without dentin bonding agent. Materials and methods. The occlusal surface of 60 intact extracted human premolars, divided into four groups, were cleaned with pumice/slurry, etched with 37% phosphoric acid for 15 seconds, rinsed and dried. Groups were treated differently: Excite bonding agent followed by Helioseal F fissure sealant in group1; Helioseal F alone in group 2; Excite bonding agent followed by Tetric Flow in group 3; and Tetric Flow alone in group 4. Light-curing was done after each application. After thermocycling, the whole surface of each specimen was coated with nail varnish except for one millimeter around the fissure sealant. The teeth were immersed in 2% basic fuchsin for 24 hours and then sectioned buccolingually. The sections were analyzed for leakage under a stereomicroscope. Data was analyzed by Kruskal-Wallis and Mann-Whitney tests at a significance level of P 0.05, except for groups 2 and 4 (P = 0.002 and groups 3 and 4 (P = 0.033. Conclusion. Use of a flowable composite with bonding agent is a good alternative for sealing pits and fissures; however, further in vitro and in vivo studies are necessary.

  20. Caries-preventive effect of a one-time application of composite resin and glass ionomer sealants after 5 years.

    NARCIS (Netherlands)

    Beiruti, N.; Frencken, J.E.F.M.; Hof, M.A. van 't; Taifour, D.; Palenstein Helderman, W.H. van

    2006-01-01

    The aim of the present trial was to (1) compare the caries-preventive effect of glass ionomer sealants, placed according to the atraumatic restorative treatment (ART) procedure, with composite resin sealants over time and (2) investigate the caries-preventive effect after complete disappearance of

  1. Effect of enamel sealants on tooth bleaching and on the color stability of the result.

    Science.gov (United States)

    Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S

    2017-04-01

    The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.

  2. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    Directory of Open Access Journals (Sweden)

    Natalia Perussi Biscola

    2016-01-01

    Full Text Available Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons.

  3. In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

    Directory of Open Access Journals (Sweden)

    Da Hye Kim

    2017-02-01

    Full Text Available Objectives Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans on the dental composite resins coated with three commercial surface sealants. Materials and Methods Composite resin (Filtek Z250 discs (8 mm in diameter, 1 mm in thickness were fabricated in a mold covered with a Mylar strip (control. In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP. The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9. Results Group OG achieved the lowest water contact angle among all groups tested (p 0.05 or significantly lower (group OG, p < 0.001 bacterial adhesion when compared with the control group. Conclusions The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

  4. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    Science.gov (United States)

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  5. Safety of food contact silicone rubber: Liberation of volatile compounds from soothers and teats

    DEFF Research Database (Denmark)

    Lund, Kirsten H.; Petersen, Jens Højslev

    2002-01-01

    The release of volatile compounds from soothers and teats made from silicone rubber has been investigated. Firstly, measurements of the total release of volatiles were performed according to the method in the draft European standard (CEN). Weight losses of 0.17-0.80% after four hours at 200 degrees......C were observed using gravimetric measurements. One product had a weight loss above the proposed CEN limit of 0.5%. Secondly, the volatile compounds were identified using a thermal desorption/cold trap injector on a gas chromatograph equipped with infrared spectroscopic (IR) and mass spectrometric (MS...

  6. Fissure sealant materials: Wear resistance of flowable composite resins.

    Science.gov (United States)

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  7. Engaging Stakeholders in Patient-Centered Outcomes Research Regarding School-Based Sealant Programs.

    Science.gov (United States)

    Chi, Donald L; Milgrom, Peter; Gillette, Jane

    2018-02-01

    Purpose: The purpose of this study was to use qualitative methods to describe the key lessons learned during the stakeholder engagement stage of planning a randomized clinical trial comparing outcomes of silver diamine fluoride (SDF) as an alternative to pit-and-fissure sealants in a school-based delivery system. Methods: Eighteen caregivers and community-based stakeholders with involvement in the school-based sealant program Sealants for Smiles from the state of Montana, were recruited for this qualitative study. United States (U.S.) Patient-Centered Outcomes Research Institute (PCORI) methodology standards were used to develop two semi-structured interview guides consisting of 6 questions. One interview guide was used for telephone interviews with caregivers and the second was used for a stakeholder focus group. Content analytic methods were used to analyze the data. Results: All participants believed that a study comparing SDF and sealants was clinically relevant. Non-caregiver stakeholders agreed with the proposed primary outcome of the study (caries prevention) whereas caregivers also emphasized the importance of child-centered outcomes such as minimizing dental anxiety associated with dental care. Stakeholders described potential concerns associated with SDF such as staining and perceptions of safety and discussed ways to address these concerns through community engagement, appropriate framing of the study, proper consent procedures, and ongoing safety monitoring during the trial. Finally, stakeholders suggested dissemination strategies such as direct communication of findings through professional organizations and encouraging insurance plans to incentivize SDF use by reimbursing dental providers. Conclusions: Involving key stakeholders in early planning is essential in developing patient-centered research questions, outcomes measures, study protocols, and dissemination plans for oral health research involving a school-based delivery system. Copyright © 2018

  8. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    Science.gov (United States)

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Effect of sealant agents on the color stability and surface roughness of nanohybrid composite resins.

    Science.gov (United States)

    Dede, Doğu Ömür; Şahin, Onur; Koroglu, Aysegül; Yilmaz, Burak

    2016-07-01

    The effect of sealant agents on the surface roughness and color stability of nanohybrid composite resins is unknown. The purpose of this in vitro study was to evaluate the effect of sealant agents on the surface roughness and color stability of 4 nanohybrid composite resin materials. Forty disks (10×2 mm) were fabricated for each nanohybrid composite resin material (Z-550, Tetric EvoCeram, Clearfill Majesty, Ice) (N=160) and divided into 4 surface treatment groups: 1 conventional polishing (control) and 3 different sealant agent (Palaseal, Optiglaze, BisCover) coupling groups (n=10). The specimens were thermocycled, and surface roughness (Ra) values were obtained with a profilometer. Scanning electron microscope images were also recorded. CIELab color parameters of each specimen were measured with a spectrophotometer before and after 7 days of storage in a coffee solution. Color differences were calculated by the CIEDE 2000 (ΔE00) formula. The data were statistically analyzed by 2-way ANOVA and by the Tukey HSD test (α=.05). The surface treatment technique significantly affected the Ra values of the composite resins tested (Pcomposite resin material was also significant for ΔE00 values (Pcomposite resin groups, significant decreases in Ra were observed only for the Palaseal agent coupled composite resin groups (except Ice) compared with the control groups (Pcomposite resin group, except for BisCover applied Clearfill Majesty (Pcomposite resin groups, significant differences were observed between the color change seen with BisCover and other sealants for Clearfill Majesty composite resin (Pcomposite resins except for Ice produced smoother surfaces. All surface sealant agents provided less discoloration of nanohybrid composite resins after coffee staining compared with conventional polishing except for BisCover applied Clearfill Majesty composite resin. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All

  10. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    Science.gov (United States)

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  11. Frequency of remnants of sealants left behind in pits and fissures of occlusal surfaces after 2 and 3 years.

    NARCIS (Netherlands)

    Hu, X.; Zhang, W.; Fan, M.; Mulder, J.; Frencken, J.E.F.M.

    2017-01-01

    OBJECTIVES: The null-hypothesis tested was that there was no difference in the frequency of remnants of high-viscosity glass-ionomer sealants left behind in pits and fissures of occlusal surfaces of first permanent molars and that of resin composite and glass-carbomer sealants. MATERIALS AND

  12. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    Science.gov (United States)

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P cermet cement was better retained than conventional resin sealants in younger children.

  13. Pit and fissure sealants versus fluoride varnishes for preventing dental decay in children and adolescents

    DEFF Research Database (Denmark)

    Hiiri, Anne; Ahovuo-Saloranta, Anneli; Nordblad, Anne

    2010-01-01

    the effectiveness of pit and fissure sealants to be statistically significantly higher than an application of fluoride varnish every 6 months in preventing occlusal decays of first molars at 23 months (with a RR of 0.74, 95% confidence interval (CI) 0.58 to 0.95); and at 4 years and 9 years (with a RR of 0.42, 95...... caries on the fluoride varnished tooth surfaces, compared to sealed plus fluoride varnished surfaces, with a RR of 0.36 (95% CI 0.21 to 0.61). AUTHORS' CONCLUSIONS: There was some evidence on the superiority of pit and fissure sealants over fluoride varnish application in the prevention of occlusal......BACKGROUND: The majority of the detected increment in dental caries among children and adolescents is confined to pit and fissure surfaces of first molars. OBJECTIVES: The objective of this study was to compare the effectiveness of pit and fissure sealants with fluoride varnishes in the prevention...

  14. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    Science.gov (United States)

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  15. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    Science.gov (United States)

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  16. Prevalence of sealants in relation to dental caries on the permanent molars of 12 and 15-year-old Greek adolescents. A national pathfinder survey

    Directory of Open Access Journals (Sweden)

    Mamai-Homata Eleni

    2011-02-01

    Full Text Available Abstract Background The use of sealants as an effective measure for the prevention of pit and fissure caries in children has been well documented by several studies; either they are used on an individual or on a public health basis. In order to plan and establish a national preventive program with sealants in a community, it is mandatory to know the epidemiological pattern of caries along with other variables influencing their use and effectiveness. Aims: To assess the utilization and distribution pattern of pit and fissure sealants on the first and second permanent molars of Greek adolescents and to evaluate whether the existing usage of sealants and some socio-demographic factors are correlated to caries prevalence on the population examined Methods A stratified cluster sample of 2481 Greek adolescents was selected according to WHO guidelines (1224 twelve and 1,257 fifteen-year-old, living in urban and rural areas in 11 districts within the country. Five calibrated examiners carried out clinical examinations, recording caries experience at the dentine threshold (BASCD criteria and presence or absence of sealants along with Socio-demographic indicators associated with oral health. Mann Whitney and Pearson's chi-square non parametric tests were utilized for assessing the data. The level of significance was p Results Sealants utilization varied considerably within the different districts, with 8,3% of the 12 and 8,0% of the 15-year-old adolescents having at least one sealed molar. Sealants reduced DMFS scores by 11% in the 12-year-olds and by 24% in the 15-year-olds, while 15-year-old adolescents from rural areas had a statistically significant (p = 0.002 less chance of having sealants (71% compared to children from urban areas. Girls had higher chance to receive sealants in both age groups (26% for the 12 and 19% for the 15-year-old as well as patients that visited the dentist for prevention compared to those visiting the dentist because they

  17. The differences of saliva pH before and after application of Bis-GMA resin based-pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Ayub Irmadani Anwar

    2016-06-01

    Full Text Available Pit and fissure sealant applications is one way to prevent caries. One of the effective ingredient as a pit and fissure sealant is a Bis-GMA resin. One of the active components  of  Bis-GMA  resin  is  sodium  fluoride,  which is capable  of releasing fluoride ions to the tooth surface and able to improve the repair and remineralization process through the replacement  of  calcium and phosphate ions found in saliva to increase the pH of saliva. This study was to determine the effect of pit and fissure sealant applications made from Bis-GMA resin to pH of saliva in children aged 6-12 years. The study design is pre and post test with control group design. Saliva samples were derived from 15 pediatric patients has met the criteria. The pH of saliva were taken before and after the application of pit and fissure sealant made from Bis-GMA and measured with pH meter. This study used a non-parametric test, the Wilcoxon Signed Rank test. The results of this study are also supported by the results of statistical tests showed p-: 0.005 (p<0.05 value, which means that there are significant differences in pH of saliva before and after the application of pit and fissure sealant made from Bis-GMA resin.

  18. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases

    OpenAIRE

    Siman, Homayoun; Techy, Fernando

    2015-01-01

    Study Design?Case report. Objective?Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperativ...

  19. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    Science.gov (United States)

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  20. Effect of Acidulated Phosphate Fluoride (APF on the Mcroleakage of Composite Flow and Fssure Sealant Restorations

    Directory of Open Access Journals (Sweden)

    Arash Poorsattar Bejeh Mir

    2012-09-01

    Full Text Available Background and Aims: A large number of investigations have revealed that physical and chemical alterations and weight loss could occur in composite materials exposed to acidic phosphate fluoride (APF gel. The purpose of this study was to assess the microleakage of a fissure sealant and a flow composite exposed to acidulated phosphate fluoride (APF gel. Materials and Methods: In this in vitro study, 60 intact human extracted premolar teeth were used. After preparing the occlusal groove, the teeth were divided into two groups (n=30. Teeth were filled with either Helioseal fissure sealant (Vivadent, Germany or Tetric flow composite (Vivadent, Germany. After that, each group was divided into two subgroups (n=15: 1.23% APF gel (Sultan, U.S.A was applied in the case subgroups, while control subgroups were preserved in normal saline solution. All of teeth were covered with 2 layers of nail varnish except for the filling zone and 1mm around the border of filling. After submerging in 0.5% fushin solution, specimens were sectioned bucco-lingually. Then dye penetration through the filling and fissure sealant was assessed by means of a stereo-microscope. The depth of dye penetration was scored. The data were analyzed using One-way ANOVA and Levene test. Results: The mean values of dye penetration were 1.26±1.09, 1.4±1.05, 1.2±1.37, and 1.4±1.35 for fissure sealant+gel, composite+gel, composite+normal saline, and normal saline groups, respectively. No significant difference was found in inter-groups (P=0.96. Conclusion: Considering the result of the present research, APF gel had no significant effect on the microleakage of Tetric flow composite filling and Helioseal fissure sealant and thus, it can be applied for routine usage.

  1. Radon penetration of concrete slab cracks, joints, pipe penetrations, and sealants

    NARCIS (Netherlands)

    Nielson, KK; Rogers, VC; Holt, RB; Pugh, TD; Grondzik, WA; deMeijer, RJ

    1997-01-01

    Radon movement through 12 test slabs with different cracks, pipe penetrations, cold joints, masonry blocks, sealants, and tensile stresses characterized the importance of these anomalous structural domains, Diffusive and advective radon transport were measured with steady-state air pressure

  2. Comparison of Caries Prevention With Glass Ionomer and Composite Resin Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Aylin Akbay Oba

    2009-11-01

    Conclusion: Under field conditions in which moisture control was not effective, a high-viscosity and less technique-sensitive glass ionomer material can be used as an effective sealant material, rather than resin.

  3. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    Science.gov (United States)

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  4. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    Science.gov (United States)

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs Portuguese adolescents. The establishment of a more targeted preventive program with better and more effective oral health education is essential, having into account socio-demographic aspects. PMID:25803849

  5. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children.

    Science.gov (United States)

    Larsson, Laura S; Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    To compare three variants of a culturally relevant and theoretically based message to determine the most influential risk-framing approach for improving intention to place dental sealants for preschool children. A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. We compared participants' scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. The mean difference in participants' stage-of-change scores (x = 1.17, n = 89, SD = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t88  = 5.81, p mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Community advisory board members determined to use the mix-framed approach in an oral health social marketing campaign with a rural, American Indian audience. © 2015 Wiley Periodicals, Inc.

  6. Effect of artificial aging on the bond durability of fissure sealants.

    Science.gov (United States)

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  7. Knowledge, value, opinion and practice about usage of pit and fissure sealant among dental professionals in Chennai, Tamil Nadu, India.

    Science.gov (United States)

    Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil

    2015-12-01

    A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for 15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.

  8. Initial experience with a synthetic sealant PleuraSeal™ after pulmonary resections: a prospective study with retrospective case matched controls

    Directory of Open Access Journals (Sweden)

    Hennings Ellen

    2010-06-01

    Full Text Available Abstract The objective of this study was to evaluate postoperative outcome and efficacy of a hydrogel tissue sealant for prevention of alveolar leakage after open lung resections. 20 consecutive patients were enrolled in the PleuraSeal™ sealant group (PSG and case matched with 20 retrospective controls (CG with standard treatment. Assessment of postoperative air leakage was performed until chest tube removal. Patients were followed until 30 days after discharge. At end of surgery, 100% in the PSG and 0% in the CG were air leak free (p The study demonstrated a superior efficacy of PleuraSeal™ sealant compared with standard surgical treatment for sustained sealing of postoperative air leakage and causes shorter air leak chest tube duration.

  9. Chemically bonded phosphate ceramic sealant formulations for oil field applications

    Science.gov (United States)

    Wagh, Arun S [Naperville, IL; Jeong, Seung-Young [Taejon, KR; McDaniel, Richard [Crest Hill, IL

    2008-10-21

    A sealant for an oil or geothermal well capable of setting within about 3 to about 6 hours at temperatures less than about 250.degree. F. for shallow wells less than about 10,000 feet and deep wells greater than about 10,000 feet having MgO present in the range of from about 9.9 to about 14.5%, KH.sub.2PO.sub.4 present in the range of from about 29.7 to about 27.2%, class C fly ash present in the range of from about 19.8 to about 36.3%, class F fly ash present in the range of from about 19.8 to about 0%, boric acid or borax present in the range of from about 0.39 to about 1.45%, and water present in the range of from about 20.3 to about 21.86% by weight of the sealant.A method of sealing wells is disclosed as are compositions for very high temperature wells is disclosed as is a composition for treating oil field wastes.

  10. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study

    Directory of Open Access Journals (Sweden)

    Lequaglie Cosimo

    2012-10-01

    Full Text Available Abstract Background Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal® could reduce air leaks detected by means of a digital chest drain system (DigiVent™, in patients undergoing lung resection (sutures and/or staples alone. Methods Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests were intraoperatively randomized to receive just sutures/staples (control group or sutures/staples plus CoSeal® (sealant group. Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. Results In total, 216 lung resection patients completed the study. Nineteen patients (18.1% in the control group and 12 (10.8% patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n = 12 of patients in the control group and 2.7% (n = 3 of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p = 0.0002 and p = 0.0013. The mean length of hospital stay was significantly shorter in the sealant group (4 days than the control group (8 days (p = 0.0001. We also observed lower costs in the sealant group than the control group. Conclusion The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Trial registration Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  11. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    Science.gov (United States)

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  12. A randomised trial of lung sealant versus medical therapy for advanced emphysema

    NARCIS (Netherlands)

    Come, Carolyn E.; Kramer, Mordechai R.; Dransfield, Mark T.; Abu-Hijleh, Muhanned; Berkowitz, David; Bezzi, Michela; Bhatt, Surya P.; Boyd, Michael B.; Cases, Enrique; Chen, Alexander C.; Cooper, Christopher B.; Flandes, Javier; Gildea, Thomas; Gotfried, Mark; Hogarth, D. Kyle; Kolandaivelu, Kumaran; Leeds, William; Liesching, Timothy; Marchetti, Nathaniel; Marquette, Charles; Mularski, Richard A.; Pinto-Plata, Victor M.; Pritchett, Michael A.; Rafeq, Samaan; Rubio, Edmundo R.; Slebos, Dirk-Jan; Stratakos, Grigoris; Sy, Alexander; Tsai, Larry W.; Wahidi, Momen; Walsh, John; Wells, J. Michael; Whitten, Patrick E.; Yusen, Roger; Zulueta, Javier J.; Criner, Gerard J.; Washko, George R.

    Uncontrolled pilot studies demonstrated promising results of endoscopic lung volume reduction using emphysematous lung sealant (ELS) in patients with advanced, upper lobe predominant emphysema. We aimed to evaluate the safety and efficacy of ELS in a randomised controlled setting. Patients were

  13. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS

    Science.gov (United States)

    The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...

  14. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    Science.gov (United States)

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  15. Design approach to sealant selection for the life of the well

    NARCIS (Netherlands)

    Bosma, M.; Ravi, K.; Driel, W.D. van; Schreppers, G.M.A.

    1999-01-01

    Recent experience in the field has demonstrated that the mechanical properties of the annular sealant are a critical factor in the success of a well. A demanding operational regime of the well such as High Pressure/High Temperature (HP/HT) and well interventions, e.g. pressure testing stimulation,

  16. Evaluation of asbestos exposure within the automotive repair industry: a study involving removal of asbestos-containing body sealants and drive clutch replacement.

    Science.gov (United States)

    Blake, Charles L; Dotson, G Scott; Harbison, Raymond D

    2008-12-01

    Two independent assessments were performed of airborne asbestos concentrations generated during automotive repair work on vintage vehicles . The first involved removal of asbestos-containing seam sealant, and the second involved servicing of a drive clutch. Despite the relatively high concentrations (5.6-28%) of chrysotile fibers detected within bulk samples of seam sealant, the average asbestos concentration for personal breathing zone (PBZ) samples during seam sealant removal was 0.006 f/cc (fibers/cubic centimeter of air). Many other air samples contained asbestos at or below the analytical limit of detection (LOD). Pneumatic chiseling of the sealant material during removal resulted in 69% of area air samples containing asbestos. Use of this impact tool liberated more asbestos than hand scraping. Asbestos fibers were only detected in air samples collected during the installation of a replacement clutch. The highest asbestos corrected airborne fiber concentration observed during clutch installation was 0.0028 f/cc. This value is approximately 100 times lower than Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) of 0.1f/cc. The airborne asbestos concentrations observed during the servicing of vintage vehicles with asbestos-containing seam sealant and clutches are comparable to levels reported for repair work involving brake components and gaskets.

  17. Clinical performance of a glass ionomer sealant protected with two different resin-based agents over a 2-year follow-up period.

    Science.gov (United States)

    Ulusoy, A T; Tunc, E S; Bayrak, Ş

    2017-03-01

    To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.

  18. Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair

    DEFF Research Database (Denmark)

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S

    2011-01-01

    The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS).......The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS)....

  19. Dental sealants and restorations and urinary bisphenol A concentrations in children in the 2003-2004 National Health and Nutrition Examination Survey.

    Science.gov (United States)

    McKinney, Christy; Rue, Tessa; Sathyanarayana, Sheela; Martin, Michael; Seminario, Ana Lucia; DeRouen, Timothy

    2014-07-01

    Resin-based dental sealants and composites contain bisphenol A-glycidyl methacrylate, a bisphenol A (BPA) derivative. The authors hypothesized that a greater number of sealants or restorations would be associated with higher urinary BPA concentrations. The authors examined urinary BPA measurements (in nanograms per milliliter) and oral examination data for 1,001 children aged 6 to 19 years from data sets of the 2003-2004 National Health and Nutrition Examination Survey (NHANES). They categorized children according to number of occlusal sealants and number of restorations, with four categories in each of the two groups. They estimated associations by using unadjusted and adjusted tobit regression models. The lowest quartile of BPA concentrations ranged from 0.3 ng/mL to 1.9 ng/mL, whereas the highest quartile ranged from 7.3 ng/mL to 149 ng/mL. In adjusted analysis, children with seven to 16 sealants had geometric mean BPA concentrations 25 percent higher than those of children with no sealants (95 percent confidence interval [CI], -14 percent to 82 percent; P = .23). In adjusted analysis, children with seven to 42 restorations had geometric mean BPA concentrations 20 percent higher than those of children with no restorations (95 percent CI, -6 percent to 53 percent; P = .13). Neither of these adjusted estimates was statistically significant. Though the findings were in the direction hypothesized, the authors did not observe a statistically significant association between a greater number of sealants or restorations and higher urinary BPA concentrations. Additional studies are needed to determine the extent of oral and systemic exposure to BPA from resin-based dental restorative materials over time. Dentists should follow this issue carefully as it develops and as the body of evidence grows. There is insufficient evidence to change practice at this time.

  20. Associations of soft flooring materials in free stalls with milk yield, clinical mastitis, teat lesions, and removal of dairy cows.

    Science.gov (United States)

    Ruud, L E; Bøe, K E; Osterås, O

    2010-04-01

    The objective was to test if there was an association between free-stall base softness and milk yield, incidence of clinical mastitis (CM), teat lesions, and removal of cows. In a questionnaire sent to 1,923 dairy farms presumed to be using free-stall housing, farmers were asked for information regarding housing and stall base; for example, the year of installation and the product name or brand of their mats or mattresses. This information was merged with data for milk yield, CM, teat lesions, and removal of cows extracted from the Norwegian Dairy Herd Recording System for the years after installation of mats or mattresses. After exclusion of invalid contributions, the data set consisted of 29,326 lactations for milk yield distributed over 363 free-stalled herds in Norway. The farms were stratified into 5 categories according to the softness of the stall surface measured as millimeter impact of a sphere with a diameter of 120 mm at 2-kN load: 1=concrete, softness of 0mm; 2=rubber, softness of 1 to 8mm; 3=soft mats, softness of 9 to 16 mm; 4=multilayer mats, softness of 17 to 24 mm; and 5=mattresses, softness over 24 mm. Lactation curves were estimated as modified Wood's lactation curves using test-day data and mixed models with repeated measurements, adjusting for days in milk, parity, and softness of free-stall flooring. Herds on concrete free-stall bases yielded 6,727+/-146 kg of milk from 5 to 305 days in milk. In comparison, herds showed a decrease of 0.3% on rubber, an increase of 2.4% on soft mats, an increase of 4.5% on multilayer mats, and an increase of 3.9% on mattresses. Compared with concrete, the hazard ratio (HR) of CM was less on rubber, multilayer mats, and mattresses [HR=0.89 (0.79-0.99), 0.85 (0.73-0.996), and 0.80 (0.73-0.88), respectively]. Compared with concrete, the HR of teat lesions was less on rubber, soft mats, multilayer mats, and mattresses [HR=0.41 (0.26-0.65), 0.33 (0.24-0.44), 0.12 (0.04-0.38), and 0.47 (0.33-0.67), respectively]. The

  1. Behavior of adhesion forces of silicone adhesive sealants and mastic butyl under the influence of ionizing radiation

    International Nuclear Information System (INIS)

    Costa, Wanderley da

    2012-01-01

    Adhesives are products that can keep materials together by bonds between the surfaces. Sealants are products that can keep filled a space between two surfaces, through a barrier that is configured as a 'bridge' between the two surfaces. The mastic is a product made of a mixture of substances with the primary butyl polymer, with the consistency of a mass not dried that can be used as a sealant. The polysiloxane, also known as silicone are the most important synthetic polymers with inorganic structure, and are matrices of silicone adhesive sealants. To demonstrate the behavior of the adhesive forces of these products under different conditions, we used five different techniques. These products were subjected to two different conditions to verify the behavior of adhesion, one at the environmental condition and another under the ionizing radiation. The results showed not only differences between products (silicone and mastic), but also that the adhesive forces have different behaviors under the conditions which the samples were subjected. With this was reached the goal of this study that aspired show the differences between the mastic and silicone, this last one is often considered - erroneously - the same as mastic. Thus it was proven that: 1. silicone can be regarded as an adhesive and a sealant at ambient conditions, 2. mastic improves substantially adhesion in an environment of ionizing radiation and this property can be an excellent alternative to the adhesive market. (author)

  2. A 12-month clinical evaluation of pit-and-fissure sealants placed with and without etch-and-rinse and self-etch adhesive systems in newly-erupted teeth

    Directory of Open Access Journals (Sweden)

    Maryam Karami Nogourani

    2012-06-01

    Full Text Available OBJECTIVES: The objective of this one-year clinical study was to investigate the effect of two adhesive systems (Adper Single Bond, a two-step etch-and-rinse and Clearfil SE Bond, a two-step self-etch system on pit-and-fissure sealant retention in newly-erupted teeth. This study compared the success of the sealants in mesial and distopalatal grooves with and without these two adhesive systems. MATERIAL AND METHODS: In a clinical trial, 35 children aged 6-8 years undergoing sealant placement were recruited. This one-year clinical study scored 70 mesial and 70 distopalatal sealants of newly-erupted permanent maxillary first molar, with a split-mouth design. All children received sealant alone in one permanent maxillary molar tooth. Children were randomized into two groups. One group received Self-etch (Se bond plus sealant and the other group received Single Bond plus sealant in another permanent maxillary molar tooth. Clinical evaluation at 3, 6 and 12 months was performed and the retention was studied in terms of the success and failure. RESULTS: The success rate of sealant in the distopalatal groove, using SeB at 3, 6 and 12 months was 93.3% (95% CI: 68.0, 99.8, 73.3% (95% CI: 44.9, 92.2 and 66.7% (95% CI: 38.4, 88.2, respectively. It was greater than that of the distopalatal groove in SB group with a success rate of 62.5% (95% CI: 35.4, 84.8, 31.3% (95% CI: 11.8, 58.7 and 31.3% (95% CI: 11.8, 58.7, at the three evaluation periods. The success rate of sealant in the mesial groove using SeB was 86.6% (95% CI: 59.5, 98.3, 53.3% (95% CI: 26.6, 78.7 and 53.3% (95% CI: 26.6, 78.7, while this was 100% (95% CI: 79.4, 100.0, 81.3% (95% CI: 54.4, 96.0 and 81.3% (95% CI: 54.4, 96.0 using SB, at 3, 6 and 12-month evaluation periods. CONCLUSIONS: These results support the use of these two bonding agents in pit-and-fissure sealants under both isolated and contaminated conditions. Further, Se bond seemed to be less sensitive to moisture contamination.

  3. Durability of sealants exposed to outdoor weathering and hot compression cycles

    Science.gov (United States)

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston

    2011-01-01

    Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...

  4. Characterization of low temperature creep properties of crack sealants using bending beam rehometry.

    Science.gov (United States)

    2009-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...

  5. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    Science.gov (United States)

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that

  6. THE EFFECT OF BONDING AND SURFACE SEALANT APPLICATION ON POSTOPERATIVE SENSITIVITY FROM POSTERIOR COMPOSITES

    Directory of Open Access Journals (Sweden)

    Neslihan TEKÇE

    2015-10-01

    Full Text Available Purpose: The purpose of the study was to evaluate the postoperative sensitivity of posterior Class I composite restoration at short-term, restorated with two different all-in-one self-etch adhesives with or without surface sealant application. Materials and Methods: 44 restorations were inserted in 11 patients who required Class I restorations in their molars. Each patient received 4 restorations, thus four groups were formed; (1 G-Aenial Bond (GC, Japan; (2 Clearfil S3 Bond (Kuraray, Japan; (3 G-Aenial Bond+Fortify Plus (Bisco, USA, (4 Clearfil S3 Bond+Fortify Plus. Sensitivity was evaluated at 24h, 7, 15, and 30 days using cold air, ice, and pressure stimuli using a visual analog scale. Comparisons of continuous variables between the sensitivity evaluations were performed using the Friedman’s One-Way Analysis of Variance with repeated measures test (p0.05. The use of Clearfil S3 Bond resulted in almost the same level of postoperative sensitivity as did the use of G-Aenial Bond. The highest sensitivity scores were observed for the surface sealant applied teeth without any statistical significance (p>0.05. Conclusions: Self etch adhesives displayed postoperative sensitivity. The sensitivity scores slightly decreased at the end of 30 days (p>0.05. Surface sealant application did not result in a decrease in sensitivity scores for either dentin adhesives.

  7. Clinical effectiveness and cost-effectiveness of fissure sealants in children and adolescents with a high caries risk

    Directory of Open Access Journals (Sweden)

    Neusser, Silke

    2014-10-01

    Full Text Available [english] In Germany, the application of resin-based pits and fissures sealants on the occlusal surfaces of permanent molars is part of individual prophylaxis for children and adolescents between six and 18 years. The individual prophylaxis is covered by the Statutory Health Insurance since 1993.The report addresses questions on medical effectiveness, cost-effectiveness, as well as ethical, social, and legal implications of pit and fissure sealants in preventing dental caries for children and adolescents at high caries risk. The results of the studies indicate a protective effect of pit and fissure sealants, particularly for children and adolescents at high caries risk. Additionally, the economic evaluation suggests a tendency for cost savings in this group. Nevertheless, a general expansion of the intervention cannot be recommended. All studies show a risk of bias in favour of pit and fissure sealing and a limited transferability to the German health care system. Studies included in the economic evaluation revealed methodological flaws. Both the economic models and primary studies do not provide reliable results.

  8. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    Science.gov (United States)

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  9. Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States); Leeper, William R., E-mail: rob.leeper@jhmi.edu [Johns Hopkins University School of Medicine, Department of Surgery (United States); Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States)

    2015-08-15

    Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

  10. THE STATE AND PERSPECTIVE OF HERMETIZATION OF UNDERGROUND STRUCTURES WITH USE OF RUBBER SEALANTS

    Directory of Open Access Journals (Sweden)

    V. I. Leshchenko

    2010-03-01

    Full Text Available The works on creation of effective rubber sealants for hermetic sealing of joints of underground structures from modular ferroconcrete and pig-iron, including tunnel elements for the underground, are carried out.

  11. PAH concentrations in lake sediment decline following ban on coal-tar-based pavement sealants in Austin, Texas

    Science.gov (United States)

    Van Metre, Peter C.; Mahler, Barbara J.

    2013-01-01

    Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.

  12. The effect of different enamel surface treatments on microleakage of fissure sealants

    Directory of Open Access Journals (Sweden)

    Asli Topaloglu-Ak

    2013-11-01

    Full Text Available Objective. The aim of this study was to evaluate the effects of different techniques of surface treatment on the microleakage of fissure sealants in permanent molar teeth in vitro. Materials and methods. 96 extracted impacted human third molars were randomly divided into 8 surface treatment groups (n=12/group as 1. Er: YAG laser; (Fidelis II, Fotona, Ljubljana, Slovenia (125 mj, 20Hz. 2. Er: YAG laser + 37% H3PO4 (15s; 3. ER: AG laser + 37% H3PO4+Prime&Bond NT; 4. Er: YAG laser + G Bond; 5. Er: YAG laser + Prime&Bond NT; 6. 37% H3PO4; 7. 37% H3PO4 + Prime &Bond NT; 8. G Bond. Sealant material (Clinpro, 3M ESPE, Seefeld, Germany, was applied into the fissures and light-cured for 20s with LED (Bluephase C5, Ivoclar-Vivadent, Schaan, Liechtenstein. Specimens were subjected to thermocycling (1000×, 5-55°C, dwell time: 15s and immersed in 0.5% basic fuchsin solution for 24h at 37°C. The samples were sectioned and scored on a 3 point rating scale using a light microscope with a magnification of ×20. One-way analysis of variance was used to analyze data. Multiple comparisons were analyzed using Bonferroni test (p=0.05. Results. Er:YAG laser showed the highest microleakage scores whereas Er YAG laser + 37% H3PO4 showed the lowest. Although 37% H3PO4 group showed higher scores than Er:YAG laser + 37% H3PO4, the difference was not statistically significant. Conclusion. Etching fissures with phosphoric acid is sufficient prior to fissure sealant application.

  13. Aluminosilicate-based sealants for SOFCs and other electrochemical applications - A brief review

    Science.gov (United States)

    Tulyaganov, Dilshat U.; Reddy, Allu Amarnath; Kharton, Vladislav V.; Ferreira, José M. F.

    2013-11-01

    Among different designs of solid oxide fuel cells (SOFCs), planar design is the most promising due to easier fabrication, improved performance and relatively high power density. In planar SOFCs and other solid-electrolyte devices, gas-tight seals must be formed along the edges of each cell and between the stack and gas manifolds. For a sealant to work effectively in high-temperature SOFC environment, equilibrium needs to be achieved amid its mechanical properties and flow behavior so that it does not only maintain its hermeticity at high temperature but is also able to reduce mechanical stresses generated in the seal during thermal cycling. The most common sealants based on glass or glass-ceramic materials have been shown to operate in fuel cells for more than 1000 h with no significant degradation. Analysis of the current literature sources demonstrated that from thermal and chemical stability points of view, silicate based glass systems are more suitable than borate and borosilicate glass systems. In this work, different glass-ceramic (GC) compositions based on alkaline- and alkaline-earth aluminosilicate-based glass systems are reviewed with a special emphasis on their thermal, chemical, mechanical, and electrical properties. Based on these considerations, glass composition design approaches are provided that aid in search of the best seal glasses satisfying the rigid functional requirements. Among all the glass systems studied, a pyroxene based CaO-MgO-SrO-BaO-La2O3-Al2O3-SiO2 seal GC compositions have been specifically discussed because those have achieved appropriate thermal and chemical properties along with high stability. Approaches for further developments and optimization of GC sealants are briefly discussed.

  14. Effectiveness of Fibrin Sealant Patch in Reducing Drain Volume after Pelvic Lymph Node Dissection in Women with Gynecologic Malignancy

    Directory of Open Access Journals (Sweden)

    Hwa Cheong Kim

    2017-01-01

    Full Text Available Background. The goal of this study was to evaluate the effectiveness of fibrin sealant in decreasing postoperative lymphatic drainage in women after pelvic lymphadenectomy and/or para-aortic lymphadenectomy during gynecologic cancer surgery. Methods. This study is a retrospective case-control study. Forty-five patients who underwent staging surgery were enrolled. Twenty-seven patients were in the fibrin sealant group (group A and 18 in the control group (group B. The two groups were compared for the total volume of drain, hospital stay, harvested lymph node, and incidence of asymptomatic lymphocele. Lymphocele formation was evaluated by computed tomography (CT on 3 months after surgery. Results. There were no significant differences in patient demographics between group A and B with respect to age, BMI, and harvested lymph nodes. Patients who received fibrin sealants had reduced total volume of drainage from postoperative days 2 to 5 compared to the control group (group A versus group B: 994.819±745.85 ml versus 1847.89±1241.41 ml; P=0.015. However no differences were observed in hospital stay (P=0.282, duration of drain (P=0.207, and incidence of asymptomatic lymphocele at 3 months (P=0.126. Conclusion. The results of this study indicate that the application of fibrin sealants after pelvic and/or para-aortic lymphadenectomy may reduce lymphatic drainage in gynecologic malignancy.

  15. No difference in sexual dysfunction after transabdominal preperitoneal (TAPP) approach for inguinal hernia with fibrin sealant or tacks for mesh fixation

    DEFF Research Database (Denmark)

    Pommergaard, H C; Burcharth, J; Andresen, K

    2017-01-01

    BACKGROUND: Postoperative sexual dysfunction in relation to laparoscopic groin hernia surgery may be related to methods of mesh fixation. However, this has not been investigated earlier. Moreover, results regarding sexual dysfunction in females have not been reported systematically. The aim...... of this study was to compare fibrin sealant versus tacks for fixation of mesh regarding sexual dysfunction in males and females. METHODS: Using the Danish Hernia Database, patients operated laparoscopically for groin hernia with a transabdominal preperitoneal (TAPP) procedure with fibrin sealant or tacks...... for mesh fixation were sent a questionnaire regarding sexual dysfunction. Sexually active patients without recurrence were evaluated in this study. RESULTS: Pain during sexual activity was present in 115 of 1019 (11.3 %) males and 17 of 147 (11.6 %) females. There was no difference between fibrin sealant...

  16. Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

    Science.gov (United States)

    Graziano, Francesca; Certo, Francesco; Basile, Luigi; Maugeri, Rosario; Grasso, Giovanni; Meccio, Flavia; Ganau, Mario; Iacopino, Domenico G.

    2015-01-01

    Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat® system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient's blood, was prepared with the Vivostat® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding control and associated complications were recorded. Results: A total of 79 neurosurgical procedures have been performed on 77 patients. In the majority of cases (98%) the same autologous fibrin glue provided rapid hemostasis and dural sealing. No patient developed allergic reactions or systemic complications in association with its application. There were no cases of cerebral hematoma, swelling, infection, or epileptic seizures after surgery whether in the immediate or in late period follow-up. Conclusions: In this preliminary study, the easy and direct application of autologous fibrin sealant agent helped in controlling cerebral bleeding and in providing prompt and efficient dural sealing with resolution of CSF leaks. Although the use of autologous fibrin glue seems to be safe, easy, and effective, further investigations are strongly recommended to quantify real advantages and potential limitations. PMID:25984391

  17. Application of rape pod sealants to reduce adverse environmental impacts.

    Science.gov (United States)

    Bauša, Laimis; Steponavičius, Dainius; Jotautienė, Eglė; Kemzūraitė, Aurelija; Zaleckas, Ernestas

    2018-04-01

    Rape (Brassica napus L.) is a major global oilseed crop characterized by its high potential as an alimentary oil and in biodiesel production. The two most popular pod sealants (PS) used to reduce rape pod shattering are products in the pinolene range (di-1-p-menthene) and latex polymer products. Reports on the effective preservation of seed yield by these products are fairly contradictory. With this in mind, an experimental PS (PS4) that contained the active agents acrylic and trisiloxane was developed. Comparative experimental trials of the developed PS4 and three other PS (PS1, PS2 and PS3) containing active agents that are generally used for sealant production were conducted. The studies showed that the static and dynamic surface tension of PS4 was the lowest at the same concentration (2.0 g kg -1 ), consequently demonstrating the lowest spray drift. The chemical substances from PS had not penetrated the rape seeds in any of the PSs. The results indicate that treatment with PS4 exerts a beneficial effect in reducing rape seed yield loss (68-104 kg ha -1 in 2014 and 194-305 kg ha -1 in 2015) compared to other investigated PS. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  18. USE OF HYDROALCOHOLIC EXTRACT OF Schinus terebinthifolius Raddi IN PRE- AND POST-MILKING ANTISEPSIS OF THE TEAT IN DAIRY COWS

    OpenAIRE

    Faccin, Ângela; Schuch, Luiz Filipe Damé; Schiavon, Diane Bender Almeida; Gonçalves, Carolina Lambrecht; Mota, Fernanda Voight; Lessa, Lisiane Ferreira

    2016-01-01

    Abstract Medicinal plants have been used for centuries as an alternative treatment for health problems. Schinus terebinthifolius Raddi is a median tree that belongs to the Anacardiaceae family. The antibacterial effect of leaves extract of this plant has already been demonstrated. The objective of this study was to test a substance derived from this plant to be used in pre- and post-milking teat antisepsis. The hydroalcoholic extract of Brazilian pepper tree was used in opposite quarters for ...

  19. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M A; Luck, R M; Yeoman, F A; Navish, Jr, F W

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance of these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.

  20. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    Science.gov (United States)

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  1. In vivo studies on lysosubtilin. 3. Efficacy for treatment of mastitis and superficial lesions of the udder and teats in cows.

    Science.gov (United States)

    Biziulevichius, G A; Lukauskas, K

    1998-01-01

    Lysosubtilin is a broad-spectrum preparation of lytic enzymes from Bacillus subtilis designed for veterinary medicine. This study demonstrates its efficacy for the treatment of reproductive system diseases (mastitis, superficial lesions of the udder and teats) in cows. Prior to determination of optimal therapeutic doses, samples taken from the milk and udder skin of sick animals were examined microbiologically. The examinations revealed a high incidence of polymicrobial infections (26.9 and 84.9% for mastitis and superficial udder lesions, respectively) caused by various mixtures of bacteria (both Gram-positive and Gram-negative) and fungi/yeasts. Dose determination studies involved 115 cows with clinical signs of mastitis. The optimal dose for mastitis treatment was found to be 3.5 x 10(6) U lysosubtilin dissolved in 100 mL of distilled water, which was then administered into the mammary gland via the teat canal once daily until recovery. Such a dose yielded statistically significant decreases (P < 0.05) both in the length of time before clinical recovery (2 d versus 4 and 4.5 d with either of the two antibiotic-based traditional drugs) and in the percentage of animals who suffered relapses within a 2-month period following treatment (5% versus 60%, with one of the two drugs). A field experiment involving 106 cows was designed to compare the efficacy of 1% lysosubtilin water-glycerin solution (1:9 v/v) and other traditional medications for the topical treatment of superficial lesions of the udder and teats as well as its potential for mastitis prevention. All drugs used yielded a 100% cure rate, but lysosubtilin application made it possible to achieve a statistically significant decrease (P < 0.05) in the duration of the recovery period (2.5 d versus 4.5 to 5.5 d) when compared with any of the four other drugs tested. Its efficacy for mastitis prevention was at least 3.4 times higher than the efficacy of the other medications used (statistically significant, P < 0

  2. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    Science.gov (United States)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  3. 40 CFR 63.6000 - How do I conduct tests and procedures for puncture sealant application affected sources?

    Science.gov (United States)

    2010-07-01

    ... Tire Manufacturing Testing and Initial Compliance Requirements for Puncture Sealant Application... balances to demonstrate compliance, if the storage of materials, exhaust, or the wastewater from more than...

  4. Pengaruh teat dipping menggunakan dekok daun kersen (Muntingia calabura L. terhadap tingkat kejadian mastitis

    Directory of Open Access Journals (Sweden)

    Indra Kurniawan

    2014-02-01

    Full Text Available ABSTRACT: The study was carried out in Sidomulyo Village, Jabung, Malang Regen-cy from April 6th to May 6th, 2013. The objective of the study was to evaluate the influ-ence of Kersen leaf (Muntingia calabura L extract to reduce mastitis incidents. The materials used in this study were 15 Friesian Holstein crossbreed lactating dairy cows, chemical antiseptic, and Kersen leaf extract. The study used experiment Randomized Block Design with 3 treatments and 5 replications. The result shows that Kersen leaf extract was significantly (p>0.05 able to reduce mastitis incidents particularly 20% of Kersen leaf extract composition. The study suggests that Kersen leaf extract can be used as an effective substance in dipping solution for dairy cows Mastitis control program. Keywords: Kersen leaf extract, mastitis, teat dipping, dairy cows

  5. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    Science.gov (United States)

    Pithon, Matheus Melo; Santos, Mariana de Jesus; de Souza, Camilla Andrade; Leão, Jorge César Borges; Braz, Ana Karla Souza; de Araujo, Renato Evangelista; Tanaka, Orlando Motohiro; Oliveira, Dauro Douglas

    2015-01-01

    Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15) according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control), only brushing was performed with 1.450 ppm fluoride; G2 (control) brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT) of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded) and depth measurement of carious lesions were performed. Analysis of variance (ANOVA) was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003), 1 and 3 (p = 0.008), 1 and 4 (p = 0.000) and 1 and 5 (p = 0.000). The group in which only brushing was performed (Group 1) showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone. PMID:26691968

  6. Two-year survival of glass ionomer sealanTs placed as parT of ...

    African Journals Online (AJOL)

    2010-09-09

    Sep 9, 2010 ... Two-year survival of glass ionomer sealanTs placed as parT of proximal aTraumaTic. resToraTive ... absTracT. Objective: To evaluate after two years, the survival rate of glass ionomer cement (gic) ... or symptoms of periodontal disease, and clinically the ..... saliva contamination on the bond of dentine resin-.

  7. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  8. Parents' Attitude towards the Use of Fluorides and Fissure Sealants and its Effect on their Children's Oral Health.

    Science.gov (United States)

    Blumer, Sigalit; Ratson, Tal; Peretz, Benjamin; Dagon, Nurit

    To characterize the attitudes of Israeli parents towards caries preventive measures. participating parents completed a 21-item questionnaire on their demographics, dental history, attitudes and satisfaction from fluorides and fissure sealants. One hundred parents (average age 41.62±4.9 years, 85 females) participated. Most of the parents (88% of the mothers and 84% of the fathers) had an academic education. Most of the parents (54%) had a favorable attitude towards the use of fluoridated gels, while only 37% of them had a positive opinion regarding fluoridated water. The satisfaction levels were very high regarding fissure sealants, fluoridated mouth rinses and fluoridated gels (78.1%, 73.6% and 72.5% respectively). The satisfaction from fluoridated water was split almost equally (50.8% were 'pleased' and 49.2% 'not pleased'). The main source for parental oral health knowledge was the dentist (83%). Parents' attitude towards caries preventive measures was significantly correlated to their gender, dental experience, level of education and the number of children in the family. positive attitude towards caries preventive measures was found among parents with higher awareness for preventive oral health measures and among bigger families. Mothers were more positive about fissure sealants than fathers. Mothers with up to 12 years of education tended to have a positive opinion regarding water fluoridation.

  9. Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

    Directory of Open Access Journals (Sweden)

    Mahtab Memarpour,

    2014-08-01

    Full Text Available Objectives The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20. The tooth surfaces were sealed with an unfilled resin fissure sealant (FS material. The experimental groups included: 1 phosphoric acid etching (AE + FS (control; 2 AE + One-Step Plus (OS, Bisco + FS; 3 bur + AE + FS; 4 bur + AE + OS + FS; 5 Er:YAG laser + AE + FS; and 6 Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM and unfilled area (PUA were measured by digital microscope. Results Overall, there were significant differences among all groups in the PM (p = 0.00. Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05. Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

  10. Effectiveness of audiovisual distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder.

    Science.gov (United States)

    Fakhruddin, Kausar Sadia; El Batawi, Hisham Yehia

    2017-01-01

    The aim of this study was to evaluate the effectiveness of audiovisual (AV) distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder. This study was conducted on 28 children diagnosed with autism spectrum disorder, aged 6.5-9.8 years. Children underwent one introductory (desensitization) appointment and three treatment sessions. During the introductory session, children had the procedures explained to them, they watched a movie projected on a screen while oral screening and assessment of cooperation level were carried out. In treatment session I, oral examination, charting, and dental x-rays were undertaken, whereas the children watched movies with or without video eyewear. During treatment sessions II/III, dental prophylaxis was carried out on upper and lower jaws in addition to the application of dental sealants on the right upper and lower and the left upper and lower permanent molars, respectively, while the children were distracted by cartoon movies using video eyewear. Changes in pulse oximeter and heart rate were recorded every 5 min. Independent samples t -test was used to assess the significance of changes in pulse and O 2 saturation levels during each visit. International Caries Detection and Assessment System-code 2 was found to be the most prevalent ( n = 58; 52%). A significant difference ( P behavior in the subjects. Video eyewear distraction proved an effective tool in managing children with autism spectrum disorder during noninvasive preventive dental procedures.

  11. A Systematic Approach to the Study of Accelerated weathering of Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; James J. Filliben; Adam L. Pintar; Greg. Schueneman

    2012-01-01

    An accurate service life prediction model is needed for building joint sealants in order to greatly reduce the time to market of a new product and reduce the risk of introducing a poorly performing product into the marketplace. A stepping stone to the success of this effort is the precise control of environmental variables in a laboratory accelerated test apparatus in...

  12. Characterization of coagulase-negative staphylococcus species from cows' milk and environment based on bap, icaA, and mecA genes and phenotypic susceptibility to antimicrobials and teat dips.

    Science.gov (United States)

    Piessens, V; De Vliegher, S; Verbist, B; Braem, G; Van Nuffel, A; De Vuyst, L; Heyndrickx, M; Van Coillie, E

    2012-12-01

    The aim of this study was to investigate whether the main coagulase-negative staphylococci (CNS) species involved in bovine intramammary infections (IMI) possess specific characteristics that promote colonization of the udder. Virulence markers associated with biofilm formation, antimicrobial resistance, and biocide tolerance were compared between typically contagious CNS species (Staphylococcus chromogenes, Staphylococcus epidermidis, Staphylococcus haemolyticus, and Staphylococcus simulans) and those rarely causing IMI (Staphylococcus sciuri, Staphylococcus equorum, and others) to find possible associations with pathogenicity. Coagulase-negative staphylococci isolates (n=366) belonging to 22 different species were analyzed by PCR for the presence of the biofilm-associated genes bap and icaA, and the methicillin resistance gene mecA. A selection of 82 isolates was additionally tested for their susceptibility to 5 antibiotics and 2 commercial teat dip products. Minimum inhibitory concentrations of antimicrobials were determined by Etest (AB bioMérieux, Marcy l'Etoile, France), and a microdilution method was optimized to determine minimum biocidal concentrations of teat dips. The bap, icaA, and mecA genes were detected significantly more in isolates from CNS species typically living in the cows' environment than in isolates from IMI-causing species. Antimicrobial resistance was mainly against erythromycin (23%) or oxacillin (16%), and was detected more often in the environmental species. The isolates least susceptible to the teat dips belonged to the IMI-causing species Staph. chromogenes and Staph. simulans. We concluded that carriage of biofilm genes and antimicrobial resistance were not associated with the ability to colonize the mammary gland because free-living CNS species constituted a more significant reservoir of biofilm and resistance determinants than did IMI-causing species. In contrast, increased tolerance to biocides may favor the establishment of

  13. Resistência ao cisalhamento de um selante associado a componentes de um sistema adesivo dental Shear bond strength of an enamel sealant using components of a dental adhesive system

    Directory of Open Access Journals (Sweden)

    Zilda Maria MUSSOLINO

    1998-10-01

    Full Text Available Cilindros de selante, padronizados, foram unidos ao esmalte das superfícies vestibulares de incisivos bovinos, após serem planificadas e condicionadas, com ácido fosfórico a 37%, durante 30 segundos. Foram utilizados 40 dentes, aleatoriamente divididos em 4 grupos, cujas coroas foram secionadas, de modo a obter-se duas porções, cervical e incisal. No Grupo I, após o condicionamento, aplicou-se o selante Fluroshield; no Grupo II, antes da aplicação do selante, uma camada do "primer" do Probond foi aplicada; no Grupo III, após o "primer", aplicou-se o adesivo do Probond; e no Grupo IV, somente o adesivo foi aplicado antes do selante. Os espécimes foram armazenados em água a 37°C, durante 36 horas, e então submetidos aos ensaios de cisalhamento. A análise estatística revelou significante diminuição na resistência ao cisalhamento, quando o "primer" foi aplicado previamente ao selante, enquanto a resistência ao cisalhamento do selante foi semelhante quando o adesivo do Probond foi aplicado, com ou sem o "primer". A resistência ao cisalhamento do selante ao esmalte é maior no terço incisal que no terço cervical da coroa.Standardized cylinders of sealants were bonded to the flattened labial enamel of bovine incisor teeth that had previously been subjected to 37% phosphoric acid gel for 30 seconds. A total of 40 teeth were tested, randomly divided in four groups of 10 teeth each. In Group I, the sealant Fluroshield was applied after etching; in Group II after etching, the "primer" of Probond was used before the sealant; in Group III after etching, the bond of Probond was used after the "primer"; and in Group IV only the bond was applied before the sealant. Specimens were stored in water at 37°C during 36 hours, before shear testing using a Universal Testing Machine. There was significant reduction in shear bond strength of the sealant when only the "primer" was used previously to the application of the sealant. There were no

  14. Cost-effectiveness, in a randomized trial, of glass-ionomer-based and resin sealant materials after 4 yr

    NARCIS (Netherlands)

    Goldman, A.S.; Chen, X.; Fan, M.; Frencken, J.E.

    2016-01-01

    This study, conducted from a government program perspective, compared the incremental cost-effectiveness of oral health interventions, in particular their delivery to underserved populations in whom dental sealants constitute an important, high-yielding complement to toothbrushing in dental-caries

  15. A case history on long-term effectiveness of clay sealant

    International Nuclear Information System (INIS)

    Lee, C.F.

    1986-01-01

    This report documents a case history in which a cadaver and the associated burial objects were found to be well-preserved after more than 2100 years of burial in Southern China. The preservation was attributed to the presence of a 60-300 cm thick kaolin or white clay layer around the tomb, which acted effectively as a barrier to moisture and air percolation. The degree of preservation in other tombs of similar age in the same area apparently depended on the mineralogy and thickness of the clay sealants used. The implication of this case history to nuclear fuel waste disposal is discussed

  16. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  17. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    Science.gov (United States)

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  18. Successful conservative treatment of enterocutaneous fistula with cyanoacrylate surgical sealant: case report.

    Science.gov (United States)

    Musa, N; Aquilino, F; Panzera, P; Martines, G

    2017-01-01

    Enterocutaneous (EC) fistula is an abnormal communication between the gastrointestinal tract and the skin. The majority of EC fistulas result from surgery. Only 15-25% of EC fistulas are spontaneous and they often result from underlying diseases such as Crohn's disease, radiation and chemotherapy. A 62-year old woman who, in 2012, underwent Pylorus-preserving cephalic pancreaticoduodenectomy (PPPD sec. Traverso-Longmire), due to an advanced pancreatic ductal adenocarcinoma (pT3N1M1). After surgery, the patient underwent chemotherapy with folfirinox regimen. In December 2016, as a result of the appearance of metastatic liver lesions and perianastomotic recurrence, the patient underwent second line treatment with Gemcitabine and pab-paclitaxel. After five months from the beginning of this new second line therapy she presented an EC fistula. The fistula of the patient was successfully treated with total parenteral nutrition and with percutaneous injection of cyanoacrylic sealant. The result suggests the advisability of percutaneous injection of sealant devices, such as cyanoacrylate glue; in order to successfully control stable Enterocutaneous fistulas with acceptable morbidity and mortality especially in particular situations, such as, with low output EC fistulas without signs of complications or on patients considered not suitable for surgery, a conservative approach could ensure the control of the fistula. This approach is easy and safe, viable and useful for future trials on the efficacy in conservative treatment of EC fistula.

  19. Motor recovery and synaptic preservation after ventral root avulsion and repair with a fibrin sealant derived from snake venom.

    Directory of Open Access Journals (Sweden)

    Roberta Barbizan

    Full Text Available BACKGROUND: Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. METHODOLOGY/PRINCIPAL FINDINGS: Female Lewis rats (7 weeks old were subjected to VRA and root replantation. The animals were divided into two groups: 1 avulsion only and 2 replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera. Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. CONCLUSIONS/SIGNIFICANCE: In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the

  20. Motor Recovery and Synaptic Preservation after Ventral Root Avulsion and Repair with a Fibrin Sealant Derived from Snake Venom

    Science.gov (United States)

    Barbizan, Roberta; Castro, Mateus V.; Rodrigues, Antônio C.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2013-01-01

    Background Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. Methodology/Principal Findings Female Lewis rats (7 weeks old) were subjected to VRA and root replantation. The animals were divided into two groups: 1) avulsion only and 2) replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera). Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. Conclusions/Significance In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the astroglial reaction and

  1. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  2. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  3. Fissure sealants in caries prevention:a practice-based study using survival analysis

    OpenAIRE

    Leskinen, K. (Kaja)

    2010-01-01

    Abstract The purpose of this study was to analyse the effectiveness and cost of fissure sealant treatment in preventing dental caries in children in a practice-based research network using survival analysis. The survival times of first permanent molars in children were analysed in three countries: in Finland (age cohorts 1970–1972 and 1980–1982), in Sweden (1980–1982) and in Greece (1980–1982), and additionally at two municipal health centres in Finland (age cohorts 1988–1990 in Kemi...

  4. Analysing uncertainty around costs of innovative medical technologies: the case of fibrin sealant (QUIXIL) for total knee replacement.

    NARCIS (Netherlands)

    Steuten, Lotte Maria Gertruda; Vallejo-Torres, Laura; Bastide, Philippe; Buxton, Martin J.

    2009-01-01

    This paper presents a relatively simple cost model comparing the costs of using a commercial fibrin sealant (QUIXIL®) in addition to conventional haemostatic treatment vs. conventional treatment alone in total knee replacement (TKR) surgery, and demonstrates and discusses how one- and two-way

  5. Evaluation of Fibrin Sealants and Tissue Adhesives in Oral Surgery for Patients with Bleeding Disorders

    Directory of Open Access Journals (Sweden)

    Gülsüm Ak

    2012-03-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the efficiency of two local haemostatic agents administered together with preoperative dose of replacement therapy for oral surgical procedures in patients with bleeding disorders METHODS: Twenty-one patients were divided into three groups randomly. Patients in Group 1 (n=7 received preoperative replacement therapy with postoperative fibrin sealant application in the surgical site. Patients in Group 2 (n=7 received preoperative replacement therapy with postoperative tissue adhesive application in the surgical site. Patients in Group 3 (n=7 were given total dose of replacement therapy pre- and postoperatively. RESULTS: No postoperative bleeding was observed in 17 patients including five patients in Group 1 (71.42%, six patients in Group 2 (85.71% and six patients in Group 3 (85.71%. Haemorrhagic complication was observed in only four patients among all groups. CONCLUSION: We conclude that utilization of fibrin sealants and tissue adhesives in oral surgery is beneficial due to the lessened amount of factor concentrates used for replacement therapy and the rapid haemostasis at the operation side to perform serial surgical procedures in the same session.

  6. Dextran/Albumin hydrogel sealant for Dacron(R) vascular prosthesis.

    Science.gov (United States)

    Lisman, Anna; Butruk, Beata; Wasiak, Iga; Ciach, Tomasz

    2014-05-01

    In this paper, the authors describe a novel type of hydrogel coating prepared from the copolymer of human serum albumin and oxidized dextran. The material was designed as a hydrogel sealant for polyester (Dacron®)-based vascular grafts. Dextran was chosen as a coating material due to its anti-thrombogenic properties. Prepared hydrogels were compared with similar, already known biomaterial made from gelatine with the same cross-linking agent. Obtained hydrogels, prepared from various ratios of oxidized dextran/albumin or oxidized dextran/gelatine, showed different cross-linking densities, which caused differences in swelling, degradation rate and mechanical properties. Permeability tests confirmed the complete tightness of the hydrogel-modified prosthesis. Results showed that application of the hydrogel coating provided leakage-free prosthesis and eliminated the need of pre-clotting.

  7. The FINISH-3 Trial : A Phase 3, International, Randomized, Single-Blind, Controlled Trial of Topical Fibrocaps in Intraoperative Surgical Hemostasis

    NARCIS (Netherlands)

    Bochicchio, Grant V.; Gupta, Navyash; Porte, Robert J.; Renkens, Kenneth L.; Pattyn, Piet; Topal, Baki; Troisi, Roberto Ivan; Muir, William; Chetter, Ian; Gillen, Daniel L.; Zuckerman, Linda A.; Frohna, Paul A.

    BACKGROUND: This Phase 3, international, randomized, single-blind, controlled trial (FINISH-3) compared the efficacy and safety of Fibrocaps, a ready-to-use, dry-powder fibrin sealant containing human plasma-derived thrombin and fibrinogen, vs gelatin sponge alone for use as a hemostat for surgical

  8. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants.

    Science.gov (United States)

    Bonetti, Debbie; Johnston, Marie; Clarkson, Jan E; Grimshaw, Jeremy; Pitts, Nigel B; Eccles, Martin; Steen, Nick; Thomas, Ruth; Maclennan, Graeme; Glidewell, Liz; Walker, Anne

    2010-04-08

    Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs) in Scotland. Outcomes were behavioural simulation (scenario decision-making), and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB), Social Cognitive Theory (SCT), Common Sense Self-regulation Model (CS-SRM), Operant Learning Theory (OLT), Implementation Intention (II), Stage Model, and knowledge (a non-theoretical construct). Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value. Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT), timeline acute (CS-SRM), and outcome expectancy (SCT) entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT) and attitude (TPB) entered the equation, together explaining 68% of the variance in intention. The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for identifying factors that may predict clinical behaviour

  9. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    Science.gov (United States)

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  10. Assessment of pain and quality of life in Lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin sealant mesh fixation

    Directory of Open Access Journals (Sweden)

    René H Fortelny

    2014-11-01

    Full Text Available Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e. the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-centre two cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e. seroma, infection, pain and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year.Results: Significantly less postoperative pain was reported in the fibrin sealant group compared to the suture group at 6 weeks (P=0.035, 6 months (P=0.023 and 1 year (P=0.011 postoperatively. Additionally trends towards a higher postoperative quality of life, a faster surgical procedure and a shorter hospital stay were seen in the fibrin sealant group.Conclusion: Fibrin sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  11. Surgical Treatment of Pressure Ulcers with a Fibrin Sealant in Patients with Spinal Cord Injury: A Cost-Consequence Analysis.

    Science.gov (United States)

    Velasco, Jose Manuel Arévalo; Lozano, Virginia; Oyagüez, Itziar; Casado, Miguel Angel

    2015-11-01

    A comparative study was performed to evaluate the effectiveness and costs of a fibrin sealant (Tissucol Duo [known as Tisseel in the United States], Baxter International, Deerfield, Illinois) to improve postoperative outcomes in patients with spinal cord injury undergoing surgical treatment for pressure ulcers (PrUs). Between January and June 2011, 27 patients underwent surgical treatment for PrUs with the direct application of Tissucol Duo sprayed before closure. The costs and outcomes obtained in this cohort were compared with those obtained in a previous retrospective study where 71 patients underwent conventional surgery. Lower rates of hematoma-seroma were observed in the study group (3.7% vs 33.8%; P costs. The application of Tissucol Duo during surgical treatment of PrUs in patients with spinal cord injury has been shown to be effective in reducing postoperative complications and in shortening the duration of the hospital stay with a consequent savings in costs.

  12. 40 CFR Table 14 to Subpart Xxxx of... - Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected Sources 14 Table 14 to Subpart XXXX of Part 63... Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 14 Table 14 to Subpart XXXX...

  13. Influence of surface sealant on the translucency of composite resin: effect of immersion time and immersion media

    Directory of Open Access Journals (Sweden)

    Patrícia Petromilli Nordi Sasso Garcia

    2008-06-01

    Full Text Available This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8 were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.

  14. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    Science.gov (United States)

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P drainage.

  15. Effect of 2 herbal intramammary products on milk quantity and quality compared with conventional and no dry cow therapy.

    Science.gov (United States)

    Mullen, K A E; Anderson, K L; Washburn, S P

    2014-01-01

    Dry cow therapy, administered at the end of lactation, is aimed at eliminating current and preventing future intramammary (IMM) bacterial infections and typically involves intramammary administration of antibiotics. Certified organic dairies in the United States are restricted from using antibiotics and must consider an alternative therapy or no dry cow therapy. The current study compared 2 herbal products to conventional dry cow therapy and no treatment for a total of 5 treatments over 2 trials. Trial 1 was conducted over 3 yr on 1 research farm and trial 2 included 4 commercial farms plus the research herd over 2 yr. Treatments included (1) a conventional IMM antibiotic and internal teat sealant (penicillin-dihydrostreptomycin and bismuth subnitrate; CON); (2) an herbal IMM product purported to act as a teat sealant (Cinnatube, New AgriTech Enterprises, Locke, NY; CIN); (3) an herbal IMM product (Phyto-Mast, Bovinity Health LLC, Narvon, PA; P-M); (4) Phyto-Mast and Cinnatube (PC); or (5) no dry cow therapy (NT). Each treatment group was balanced by breed, lactation number, due date, herd, and year. However, the CON treatment was used only in the research herd because of the intent to avoid antibiotic usage on the other 4 farms. Comparisons among treatments included the difference between pre- and posttreatment 305-d mature equivalent milk production (trial 1), somatic cell score change from dry-off to freshening at the cow and quarter levels (trials 1 and 2), and milk microbiology change over the dry period (trial 2). We detected no significant differences among treatments for milk yield differences between the lactation following treatment and the lactation preceding treatment. Changes in somatic cell score from one lactation to the next also did not differ significantly among treatments in either trial. Cure rates were not significantly different among treatments; only 19.6% of all quarters were infected at dry off. The proportion of quarters with new

  16. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants

    Directory of Open Access Journals (Sweden)

    Maclennan Graeme

    2010-04-01

    Full Text Available Abstract Background Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Methods Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs in Scotland. Outcomes were behavioural simulation (scenario decision-making, and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB, Social Cognitive Theory (SCT, Common Sense Self-regulation Model (CS-SRM, Operant Learning Theory (OLT, Implementation Intention (II, Stage Model, and knowledge (a non-theoretical construct. Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value Results Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT, timeline acute (CS-SRM, and outcome expectancy (SCT entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT and attitude (TPB entered the equation, together explaining 68% of the variance in intention. Summary The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for

  17. Detection of occlusal caries with impedance spectroscopy and laser fluorescence before and after placement of fissure sealants: An in vitro study

    DEFF Research Database (Denmark)

    Mortensen, Diana; Ekstrand, Kim; Twetman, Svante

    2016-01-01

    , the DIAGNOdent pen and ICDAS at baseline, after bleaching, etching and placement of a clear fissure sealant. A digital radiograph was exposed at baseline. After the assessments, the actual lesion depth was histologically determined.  Results : Bleaching did not affect the readings but significantly higher ACIS...

  18. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications.

    Science.gov (United States)

    Ramsson, Eric S; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants.

  19. Coal-tar pavement sealants might substantially increase children's PAH exposures

    Science.gov (United States)

    Williams, E. Spencer; Mahler, Barbara J.; Van Metre, Peter C.

    2012-01-01

    Dietary ingestion has been identified repeatedly as the primary route of human exposure to polycyclic aromatic hydrocarbons (PAHs), seven of which are classified as probable human carcinogens (B2 PAHs) by the U.S. EPA. Humans are exposed to PAHs through ingestion of cooked and uncooked foods, incidental ingestion of soil and dust, inhalation of ambient air, and absorption through skin. Although PAH sources are ubiquitous in the environment, one recently identified PAH source stands out: Coal-tar-based pavement sealant—a product applied to many parking lots, driveways, and even playgrounds primarily in the central, southern, and eastern U.S.—has PAH concentrations 100–1000 times greater than most other PAH sources. It was reported recently that PAH concentrations in house dust in residences adjacent to parking lots with coal-tar-based sealant were 25 times higher than in residences adjacent to unsealed asphalt parking lots.

  20. Avaliação clínica de uma resina composta modificada por poliácido, utilizada como selante oclusal, quando aplicada por dentista, THD e graduando Clinical evaluation of a polyacid-modified resin composite, used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate

    Directory of Open Access Journals (Sweden)

    Roberta Tarkany BASTING

    1999-04-01

    Full Text Available O presente trabalho tem por finalidade comparar as diferenças de retenção de uma resina composta modificada por poliácido (Variglass V.L.C., utilizada como selante oclusal, quando aplicada por dentista, THD e graduando em Odontologia. Foram seladas as superfícies oclusais de 370 primeiros molares permanentes superiores de crianças entre 6 e 8 anos de idade provenientes de escolas públicas do município de Piracicaba. As avaliações clínicas foram realizadas após seis e oito meses da aplicação do selante. Aos seis meses, verificou-se que 78,42% dos selantes clinicamente aceitáveis permaneceram retidos sobre a superfície oclusal. O índice de perdas totais corresponderam a 10,20% do total de selantes aplicados. O melhor índice de retenção total foi obtido quando aplicado por graduando. Aos 12 meses, houve um aumento do número de selantes perdidos (43,79% e conseqüente decréscimo do número de selantes totalmente retidos (18,96%, não havendo diferenças significativas de retenção do selante quando aplicado por dentista, THD e graduando. Nos casos de perdas totais do selante, não se constatou presença de lesão cariosa.The aim of this work is to evaluate the differences of clinical retention of a polyacid-modified resin composite (Variglass V.L.C., used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate in Dentistry. The occlusal surfaces of 370 superior first molars of children ageing from 6 to 8 years from public schools in Piracicaba, were sealed. The presented data are related to the final evaluation after 6 and 12 months. It was observed that after 6 months, 78.42% of the sealants clinically acceptable, remained on the occlusal surfaces and that the completely lost sealants reached 10.20%. The best results of the sealants retention were obtained when the sealants were applied by an undergraduate. After 12 months, there was an increase of completely lost sealants (43.79% and a decrease of

  1. Bovine teat microbiome analysis revealed reduced alpha diversity and significant changes in taxonomic profiles in quarters with a history of mastitis

    Directory of Open Access Journals (Sweden)

    Helene eFalentin

    2016-04-01

    Full Text Available Mastitis is a mammary gland inflammatory disease often due to bacterial infections. Like many other infections, it used to be considered as a host-pathogen interaction driven by host and bacterial determinants. Until now, the involvement of the bovine mammary gland microbiota in the host-pathogen interaction has been poorly investigated, and mainly during the infectious episode. In this study, the bovine teat microbiome was investigated in 31 quarters corresponding to 27 animals, which were all free of inflammation at sampling time but which had different histories regarding mastitis: from no episode of mastitis on all the previous lactations (Healthy quarter, Hq to one or several clinical mastitis events (Mastitic quarter, Mq. Several quarters whose status was unclear (possible history of subclinical mastitis were classified as NDq. Total bacterial DNA was extracted from foremilk samples and swab samples of the teat canal. Taxonomic profiles were determined by pyrosequencing on 16s amplicons of the V3-4 region. Hq quarters showed a higher diversity compared to Mq ones (Shannon index: ~8 and 6, respectively. Clustering of the quarters based on their bacterial composition made it possible to separate Mq and Hq quarters into two separate clusters (C1 and C2, respectively. Discriminant analysis of taxonomic profiles between these clusters revealed several differences and allowed the identification of taxonomic markers in relation to mastitis history. C2 quarters were associated with a higher proportion of the Clostridia class (including genera such as Ruminococcus, Oscillospira, Roseburia, Dorea, etc., the Bacteroidetes phylum (Prevotella, Bacteroides, Paludibacter, etc., and the Bifidobacteriales order (Bifidobacterium, whereas C1 quarters showed a higher proportion of the Bacilli class (Staphylococcus and Chlamydiia class. These results indicate that microbiota is altered in udders which have already developed mastitis, even far from the

  2. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing.

    Science.gov (United States)

    Gomes-Silva, Jaciara Miranda; Torres, Carolina Paes; Contente, Marta Maria Martins Giamatei; Oliveira, Maria Angélica Hueb de Menezes; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2008-01-01

    This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

  3. Bone induction by composites of bioresorbable carriers and demineralized bone in rats: a comparative study of fibrin-collagen paste, fibrin sealant, and polyorthoester with gentamicin

    DEFF Research Database (Denmark)

    Pinholt, E M; Solheim, E; Bang, G

    1992-01-01

    fibrin-collagen paste and fibrin sealant inhibited bone induction and produced a chronic inflammation; part of the fibrin-collagen paste was still present at 4 weeks. Polyorthoester with gentamicin was almost completely absorbed, induced minimal tissue reaction, and did not inhibit osteoinduction....

  4. Effects of alternative deep bedding options on dairy cow preference, lying behavior, cleanliness, and teat end contamination.

    Science.gov (United States)

    Wolfe, T; Vasseur, E; DeVries, T J; Bergeron, R

    2018-01-01

    Cows spend more time lying down when stalls are soft and dry, and bedding plays a key role in the comfort of the lying surface. The first objective of this study (experiment 1) was to compare cow preference for 2 types of alternative deep-bedding materials, switchgrass and switchgrass-lime, using wheat straw on a rubber mat as a control. Nine Holstein lactating cows were submitted in trios to a 3-choice preference test over 14 d (2 d of adaptation, 3 d of restriction to each stall, and 3 d of free access to all 3 stalls). Cows were housed individually in pens containing 3 stalls with different lying surfaces: (1) rubber mat with chopped wheat straw (WS); (2) deep-bedded switchgrass (SG); and (3) deep-bedded switchgrass, water, and lime mixture (SGL). The second objective (experiment 2) was to test, in freestall housing, the effects of these 3 types of bedding on lying behavior, cow cleanliness, and teat end bacterial contamination. Bedding treatments were compared in a 3 × 3 Latin square design using 24 cows split into groups of 8, with bedding materials being switched every 4 wk. Lying behavior was measured with data loggers in both studies. During experiment 1, cows chose to spend more time lying and had more frequent lying bouts on SG (9.4 h/d; 8.2 bouts/d) than on SGL (1.0 h/d; 0.9 bouts/d). They also spent more time standing and stood more frequently in stalls with SG (2.0 h/d; 10.1 bouts/d) than in those with SGL (0.6 h/d; 2.6 bouts/d), and stood longer in stalls with SG than with WS (0.6 h/d). In experiment 2, the total lying time, frequency of lying bouts, and mean lying bout duration were, on average, 9.7 ± 1.03 h/d, 8.2 ± 0.93 bouts/d, and 1.2 ± 0.06 h/bout, respectively, and did not differ between treatments. No treatment effects were found for cow cleanliness scores. Bedding dry matter was highest for SG (74.1%), lowest for SGL (63.5%), and intermediate for WS (68.6%) [standard error of the mean (SEM) = 1.57%]. This may explain the higher teat end

  5. Fissure sealants: in vitro evaluation of abrasion wear and superficial roughness

    Directory of Open Access Journals (Sweden)

    Vanessa Pardi

    2008-06-01

    Full Text Available The aim of this study was to compare the in vitro wear and superficial roughness of four materials (Delton Dyract Flow, Dentsply; Filtek Flow, Vitremer, 3M ESPE used as fissure sealant in 32 extracted human molars divided in four groups (n = 8 after abrasion with toothbrush/dentifrice. Impressions of each occlusal surface were made to analyze wear and circular specimens were prepared to analyze the roughness. Teeth and specimens were mounted in a toothbrushing machine. The replicas were observed using a SEM to determine the superficial wear. Wear: there were no statistically significant differences either between Delton and Filtek Flow or between Dyract Flow and Vitremer. Roughness: there were no statistical differences between Filtek Flow and Dyract Flow, Dyract Flow and Vitremer, Vitremer and Delton., Considering the clinical practice, if caries activity is present the use of Vitremer is suggested not only for its well known fluoride release, but it presented good roughness results.

  6. Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

    Directory of Open Access Journals (Sweden)

    Patricia M. de Groot, MD

    2018-04-01

    Full Text Available Purpose: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT on computed tomography (CT scans after the use of tract sealants can mimic malignant tract seeding (MTS and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. Methods and materials: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. Results: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5] showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92% or decreased (6.3% over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%. MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. Conclusions: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.

  7. Use of FloSeal Sealant in the Surgical Management of Tubal Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Mara Clapp

    2013-01-01

    Full Text Available Background. Surgery is sometimes required for the management of tubal ectopic pregnancies. Historically, surgeons used electrosurgery to obtain hemostasis. Topical hemostatic sealants, such as FloSeal, may decrease the reliance on electrosurgery and reduce thermal injury to the tissue. Case. A 33-year-old G1 P0 received methotrexate for a right tubal pregnancy. The patient became symptomatic six days later and underwent a laparoscopic right salpingotomy. After multiple unsuccessful attempts to obtain hemostasis with electrocoagulation, FloSeal was used and hemostasis was obtained. Six weeks later, a hysterosalpingogram (HSG confirmed tubal patency. The patient subsequently had an intrauterine pregnancy. Conclusion. FloSeal helped to achieve hemostasis during a laparoscopic salpingotomy and preserve tubal patency. FloSeal is an effective alternative and adjunct to electrosurgery in the surgical management of tubal pregnancy.

  8. The effect of biological sealants and adhesive treatments on matrix metalloproteinase expression during renal injury healing.

    Directory of Open Access Journals (Sweden)

    José Miguel Lloris-Carsí

    Full Text Available Renal injuries are relatively common in cases of abdominal trauma. Adhesives and sealants can be used to repair and preserve damaged organs. Using a rat model, this study explores the activity of different matrix metalloproteinases (MMP during the healing of renal injuries treated by two biological adhesives (TachoSil and GelitaSpon and a new synthetic elastic cyanoacrylate (Adhflex.Renal traumatic injuries were experimentally induced in 90 male Wistar rats by a Stiefel Biopsy Punch in the anterior aspect of the left kidney. Animals were divided into five groups: 1, sham non-injured (n = 3; 2, non-treated standard punch injury (n = 6; 3, punch injury treated with TachoSil (n = 27; 4, punch injury treated with GelitaSpon (n = 27; and, 5, punch injury treated with Adhflex (n = 27. Wound healing was evaluated 2, 6, and 18 days after injury by determining the expression of MMPs, and the histopathological evolution of lesions.Histologically, the wound size at 6 days post-injury was larger in Adhflex-treated samples than in the other treatments, but the scarring tissue was similar at 18 days post-injury. Only the MMPs subtypes 1, 2, 8, 9, and 13 were sufficiently expressed to be quantifiable. Both time since injury and treatment type had a significant influence on MMPs expression. Two days after injury, the expression of MMP8 and MMP9 was predominant. MMP2 expression was greater 6 days after injury. The Adhflex-treated group had a significantly higher MMPs expression than the other treatment groups at all healing stages.All three sealant treatments induced almost similar expression of MMPs than untreated animals indicating a physiological healing process. Given that all renal trauma injuries must be considered emergencies, both biological and synthetic adhesives, such as Adhflex, should be considered as a treatment options.

  9. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    Science.gov (United States)

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  10. Use of a culture-independent on-farm algorithm to guide the use of selective dry-cow antibiotic therapy.

    Science.gov (United States)

    Vasquez, A K; Nydam, D V; Foditsch, C; Wieland, M; Lynch, R; Eicker, S; Virkler, P D

    2018-06-01

    An algorithm using only computer-based records to guide selective dry-cow therapy was evaluated at a New York State dairy farm via a randomized field trial. DairyComp 305 (Valley Ag Software, Tulare, CA) and Dairy Herd Improvement Association test-day data were used to identify cows as low risk (cows that might not benefit from dry-cow antibiotics) or high risk (cows that will likely benefit). Low-risk cows were those that had all of the following: somatic cell count (SCC) ≤200,000 cells/mL at last test, an average SCC ≤200,000 cells/mL over the last 3 tests, no signs of clinical mastitis at dry-off, and no more than 1 clinical mastitis event in the current lactation. Low-risk cows were randomly assigned to receive intramammary antibiotics and external teat sealant (ABXTS) or external teat sealant only (TS) at dry-off. Using pre-dry-off and postcalving quarter-level culture results, low-risk quarters were assessed for microbiological cure risk and new infection risk. Groups were also assessed for differences in first-test milk yield and linear scores, individual milk weights for the first 30 d, and culling and mastitis events before 30 d in milk. A total of 304 cows and 1,040 quarters in the ABXTS group and 307 cows and 1,058 quarters in the TS group were enrolled. Among cows to be dried, the proportion of cows that met low-risk criteria was 64% (n = 611/953). Of cultures eligible for bacteriological cure analysis (n = 171), 93% of ABXTS cured, whereas 88% of TS cured. Of the non-cures, 95% were contributed by the minor pathogens coagulase-negative staphylococci (n = 19/20). These organisms also accounted for 57.5% of new infections (n = 77/134). We found no statistical differences between treatment groups for new infection risk (TS = 7.3% quarters experiencing new infections; ABXTS = 5.5%), milk production (ABXTS = 40.5 kg; TS = 41.2 kg), linear scores (ABXTS = 2.5; TS = 2.7), culling events (ABXTS, n = 18; TS, n = 15), or clinical mastitis events (ABXTS, n

  11. Design and characterisation of a polyethylene oxide matrix with the potential use as a teat insert for prevention/treatment of bovine mastitis.

    Science.gov (United States)

    Bhattarai, Sushila; Alany, Raid G; Bunt, Craig R; Abdelkader, Hamdy; Rathbone, Michael J

    2015-01-01

    This manuscript reports (for the first time) on antibiotic-free polymeric inserts for the prevention and/or treatment of bovine mastitis. Polyethylene oxide (PEO)-based inserts were prepared using different concentrations of various hydrophilic polymers and water-soluble and water-insoluble drug-release-modifying excipients. A simple and scalable melt-extrusion method was employed to prepare the inserts. The prepared inserts were characterised for their dimension, rheological and mechanical properties. The in vitro release of a model bacteriostatic drug (salicylic acid) from the prepared inserts was studied to demonstrate the effectiveness and reproducibility of the melt-extrusion manufacturing method. Further, the in vitro stability of the inserts was evaluated using gel permeation chromatography (GPC) to monitor any change in molecular weight under real-time and accelerated storage conditions. The investigated inserts were stable at accelerated storage conditions over a period of 6 months. PEO inserts have the potential to serve a dual purpose, act as a physical barrier against pathogens invading the teat canal of cows and possibly control the release of a drug.

  12. Laparoendoscopic single-site myomectomy and the use of fibrin sealant (Tisseel

    Directory of Open Access Journals (Sweden)

    Angelito Magno

    2015-11-01

    ensured after the suturing. A fibrin sealant, Tisseel (Baxter Healthcare Corp., Deerfield, IL, is applied over the suture site as an adjunct to hemostasis and also to prevent adhesion. The fundamental advantage of LESS is less incision, as a result, improves cosmesis. LESS myomectomy has many technical difficulties, including reduced visualization, loss of triangulation, and instrument interference. Thus, the type, location and numbers of the myomas are critical to succeed LESS myomectomy. The Food and Drug Administration has approved fibrin sealant in 1998 as an adjunct to hemostasis and sealing. Besides, certain studies have reported its anti-adhesion property. Upon mixing of the two components in the lumens of Tisseel, the combinations of thrombin and fibrinogen transformed into fibrin, forming a rubber-like tissue that adheres to the wound surface.

  13. Acid neutralizing, mechanical and physical properties of pit and fissure sealants containing melt-derived 45S5 bioactive glass.

    Science.gov (United States)

    Yang, Song-Yi; Piao, Yin-Zhu; Kim, Sung-Min; Lee, Yong-Keun; Kim, Kyoung-Nam; Kim, Kwang-Mahn

    2013-12-01

    The aim of this study was to examine the effects of 45S5 bioactive glass (BAG) on the acid neutralizing, mechanical and physical properties of pit and fissure sealants. 45S5BAG (glass (180 ± 30 nm) and added into a resin matrix [Bis-GMA/TEGDMA 50/50 (wt%) containing 1% of DMAEMA/CQ 2:1 (wt%)] with varying filler proportions; 0% 45S5BAG+50% glass (BAG0); 12.5% 45S5BAG+37.5% glass (BAG12.5); 25% 45S5BAG+25% glass (BAG25); 37.5% 45S5BAG+12.5% glass (BAG37.5); and 50% 45S5BAG+0% glass (BAG50). To evaluate the acid neutralizing properties, specimens were immersed in lactic acid solution (pH 4.0). Then, the change in pH and the time required to raise the pH from 4.0 to 5.5 were measured. In addition, flexural strength, water sorption and solubility were analyzed. The acid neutralizing properties of each group exhibited increasing pH values as more 45S5BAG was added, and the time required to raise the pH from 4.0 to 5.5 became shorter as the proportion of 45S5BAG increased (P0.05), except for BAG50. The novel pit and fissure sealants neutralized the acid solution (pH 4.0) and exhibited appropriate mechanical and physical properties. Therefore, these compounds are suitable candidates for caries-inhibiting dental materials. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Wear and superficial roughness of glass ionomer cements used as sealants, after simulated toothbrushing Desgaste e rugosidade superficial de cimentos de ionômero de vidro utilizados como selantes, após escovação simulada

    Directory of Open Access Journals (Sweden)

    Daniela Rios

    2002-12-01

    Full Text Available The purpose of this study was to evaluate, in vitro, the properties (wear and roughness of glass ionomer cements that could influence their indication as pit and fissure sealants. The utilized materials were Fuji Plus, Ketac-Molar and Vitremer (in two different proportions: 1:1 and ¼:1. The resin-based sealant Delton was used as control. By means of an electronic balance (precision of 10-4 g, wear was measured in function of weight loss after simulated toothbrushing. Superficial roughness was determined by means of a surface roughness-measuring apparatus. The results revealed that diluted Vitremer and Fuji Plus were less resistant to toothbrushing abrasion and had the greatest increase in superficial roughness.Although in clinical situations luting or diluted ionomer cements are often utilized as alternatives to resin-based sealants, the resultsof this study revealed that the properties of those cements are worse than those of restorative ionomers, whichpresented results similar to those of the evaluated resin sealant.O presente estudo foi conduzido in vitro com o intuito de constatar as propriedades (desgaste e rugosidade dos CIV, as quais influenciam na sua indicação como material selador de fossas e fissuras. Os materiais empregados foram Fuji Plus, Ketac-Molar e Vitremer (duas proporções: 1:1 e ¼:1. O selante Delton foi controle. A determinação do desgaste foi obtida através da quantidade de massa perdida após a escovação e a rugosidade através da análise quantitativa da superfície. Os resultados mostraram que o Vitremer diluído e o Fuji Plus apresentaram maior grau de desgaste e maior aumento de rugosidade. Apesar de clinicamente se encontrar um maior uso dos ionômeros de vidro cimentantes ou diluídos como forma alternativa para material selador; este trabalho permitiu concluir que estes possuem propriedades bastante inferiores quando comparados aos ionômeros restauradores que, por sua vez, possuem resultados semelhantes

  15. Bioadhesives for internal medical applications: A review.

    Science.gov (United States)

    Zhu, Wenzhen; Chuah, Yon Jin; Wang, Dong-An

    2018-04-22

    Bioadhesives such as tissue adhesives, hemostatic agents, and tissue sealants have gained increasing popularity in different areas of clinical operations during the last three decades. Bioadhesives can be categorized into internal and external ones according to their application conditions. External bioadhesives are generally applied in topical medications such as wound closure and epidermal grafting. Internal bioadhesives are mainly used in intracorporal conditions with direct contact to internal environment including tissues, organs and body fluids, such as chronic organ leak repair and bleeding complication reduction. This review focuses on internal bioadhesives that, in contrast with external bioadhesives, emphasize much more on biocompatibility and adhesive ability to wet surfaces rather than on gluing time and intensity. The crosslinking mechanisms of present internal bioadhesives can be generally classified as follows: 1) chemical conjugation between reactive groups; 2) free radical polymerization by light or redox initiation; 3) biological or biochemical coupling with specificity; and 4) biomimetic adhesion inspired from natural phenomena. In this review, bioadhesive products of each class are summarized and discussed by comparing their designs, features, and applications as well as their prospects for future development. Despite the emergence of numerous novel bioadhesive formulations in recent years, thus far, the classification of internal and external bioadhesives has not been well defined and universally acknowledged. Many of the formulations have been proposed for treatment of several diseases even though they are not applicable for such conditions. This is because of the lack of a systematic standard or evaluation protocol during the development of a new adhesive product. In this review, the definition of internal and external bioadhesives is given for the first time, and with a focus on internal bioadhesives, the criteria of an ideal internal

  16. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures

    Directory of Open Access Journals (Sweden)

    Aguilar F

    2007-01-01

    Full Text Available This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield and a photochromatic flowable composite resin (Tetric Flow Chroma placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars were sealed with each material, isolated (except for the sealed surface and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab. The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove′s total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment - 30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab. The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days. New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way anova and Tukey′s test P < 0.05. Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  17. Measurement of properties of sealant materials for solid oxide fuel cell systems

    International Nuclear Information System (INIS)

    Boersma, R.J.; Sammes, N.M.; Zhang, Y.

    1998-01-01

    Thermal expansion of ceramic materials, ceramic cements and steels was studied, and their compatibility with materials used in the SOFC system was evaluated. A number of ceramic cements, a glass paste and a glass ceramic were examined to identify their potential as a sealing material in a tubular fuel cell system. Thermal expansion coefficients of these materials were compared for thermal matching with materials employed in the fuel cell construction, such as yttria stabilised with 8 mole% zirconia (8YSZ) and stainless steel. A reasonable match was found for Macor, a glass ceramic, with one of the steel samples studied and with 8YSZ. Candidate sealants were tested for bonding quality, which made it evident that the ceramic cements had to be discarded. Good bonds between Macor and one of the steel samples and Macor and 8YSZ were formed, resulting in a gas tight seal. Uncertainty remains regarding the long term effect of the interface reactions between steel and Macor. Exposure of the Macor and a steel-Macor-8YSZ assembly to the different fuel cell gas atmospheres revealed that the Macor reacts with hydrogen, the long term effect of which is also unknown. Copyright (1998) Australasian Ceramic Society

  18. Comparison of six different methods of cleaning and preparing occlusal fissure surface before placement of pit and fissure sealant: An in vitro study

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2012-01-01

    Full Text Available Aim & Objectives : The purpose of this in vitro study was to evaluate and compare the microleakage of pit and fissure sealants after using six different preparation techniques: (a brush, (b pumice slurry application, (c bur, (d air polishing, (e air abrasion, and (f longer etching time. Material & Method : The study was conducted on 60 caries-free first premolars extracted for orthodontic purpose. These teeth were randomly assigned to six groups of 10 teeth each. Teeth were prepared using one of six occlusal surface treatments prior to placement of Clinpro" 3M ESPE light-cured sealant. The teeth were thermocycled for 500 cycles and stored in 0.9% normal saline. Teeth were sealed apically and coated with nail varnish 1 mm from the margin and stained in 1% methylene blue for 24 hours. Each tooth was divided buccolingually parallel to the long axis of the tooth, yielding two sections per tooth for analysis. The surfaces were scored from 0 to 2 for the extent of microleakage. Statistical Analysis : Results obtained for microleakage were analyzed by using t-tests at sectional level and chi-square test and analysis of variance (ANOVA at the group level. Results : The results of round bur group were significantly superior when compared to all other groups. The application of air polishing and air abrasion showed better results than pumice slurry, bristle brush, and longer etching time. Round bur group was the most successful cleaning and preparing technique. Air polishing and air abrasion produced significantly less microleakage than traditional pumice slurry, bristle brush, and longer etching time.

  19. Autologous but not Fibrin Sealant Patches for Stump Coverage Reduce Clinically Relevant Pancreatic Fistula in Distal Pancreatectomy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Weniger, Maximilian; D'Haese, Jan Goesta; Crispin, Alexander; Angele, Martin Kurt; Werner, Jens; Hartwig, Werner

    2016-11-01

    Postoperative pancreatic fistula (POPF) causes significant morbidity and mortality after distal pancreatectomy. Patch coverage of the pancreatic stump is often used with the intention to prevent POPF. Despite numerous investigations, the effects of patch coverage remain unclear. The present meta-analysis aims to clarify the effects of patch coverage in distal pancreatectomy on the incidence of POPF. A systematic search of MEDLINE/PubMed and the Cochrane Database according to the PRISMA Statement was performed. Subsequently a meta-analysis on rates and overall incidence of POPF and length of hospital stay was carried out. By applying the inverse variance weighting method, the combined effect size and 95 % confidence interval were calculated. Heterogeneity was assessed using I 2 statistics. Five randomized controlled trials and six observational clinical studies were included for final analysis. A cumulative incidence of 43 % of POPF grades A-C was identified. Patch coverage in distal pancreatectomy is significantly associated with a decreased rate of POPF grade C (p = 0.006). Patches of autologous vascularized tissue significantly reduce the overall incidence of POPF (p = 0.04) and clinically relevant POPF grade B and C (p = 0.002). Fibrin sealant patches do not influence rates of POPF after distal pancreatectomy. None of the outcomes evaluated showed adverse results for the patch group. Patch coverage after distal pancreatectomy can reduce the rate of POPF. Patch coverage with autologous vascularized tissue but not fibrin sealant patches may be used to reduce clinically relevant POPF and postoperative morbidity in distal pancreatectomy.

  20. The efficiency and safety of fibrin sealant for reducing blood loss in primary total hip arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Zhiyuan; Xiao, Lin; Guo, Hao; Zhao, Guanghui; Ma, Jianbing

    2017-01-01

    Total hip arthroplasty (THA) is associated with substantial blood loss. The objective of present systematic review and meta-analysis is to provide evidence from randomized controlled trials (RCTs) on the efficiency and safety of administration of fibrin sealant (FS) for reducing blood loss in patients undergoing primary THA. Potential relevant studies were identified from electronic databases including Medline, PubMed, Embase, ScienceDirect, web of science and Cochrane Library. Gray academic studies were also identified from the reference list of included studies. There was no language restriction. Pooling of data was carried out by using RevMan 5.1. Six randomized controlled trials (RCTs) met the inclusion criteria. Current meta-analysis indicated that there were significant differences in terms of total blood loss (MD = -153.77, 95% CI: -287.21 to -20.34, P = 0.02), postoperative hemoglobin level (MD = -0.25, 95% CI: -0.46 to -0.05, P = 0.02) and transfusion rate (RD = -0.12, 95% CI: -0.22 to -0.03, P = 0.01) between groups. No significant differences were found regarding the incidence of deep venous thrombosis (DVT) (RD = 0.00, 95% CI: -0.01to 0.01, P = 0.51) or other side effects. Administration of fibrin sealant in total hip arthroplasty may reduce total blood loss, postoperative hemoglobin decline and transfusion requirements. Moreover, no adverse effect was related to FS. Due to the limited quality of the evidence currently available, higher quality RCTs are required. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Decision tree analysis to evaluate dry cow strategies under UK conditions

    NARCIS (Netherlands)

    Berry, E.A.; Hogeveen, H.; Hillerton, J.E.

    2004-01-01

    Economic decisions on animal health strategies address the cost-benefit aspect along with animal welfare and public health concerns. Decision tree analysis at an individual cow level highlighted that there is little economic difference between the use of either dry cow antibiotic or an internal teat

  2. Teated

    Index Scriptorium Estoniae

    2008-01-01

    Kontserdid TÜ aulas: Tartu Ülikooli kammerkoori kevadkontsert 16. märtsil, pianist Peep Lassmann 18. märtsil (kavas: Sumera "Pala aastast 1981", Liszt-Rossini "Stabat Mater", Liszt-Verdi "Rigoletto parafraas", Liszt "Tuisk" ja "Hispaania rapsoodia"), saksofonikvartett Sax-Est 19. märtsil, kontsert "Richard Ritsing - 105" 28. märtsil

  3. Prevention of lymphocele by using gelatin-thrombin matrix as a tissue sealant after pelvic lymphadenectomy in patients with gynecologic cancers: a prospective randomized controlled study.

    Science.gov (United States)

    Kim, Yun Hwan; Shin, Hyun Joo; Ju, Woong; Kim, Seung Cheol

    2017-05-01

    This prospective randomized controlled pilot study aimed to find whether gelatin-thrombin matrix used as a tissue sealant (FloSeal) can prevent the occurrence of pelvic lymphocele in patients with gynecologic cancer who has undergone pelvic lymphadenectomy. Each patient, who undergo a laparotomic pelvic lymph node dissection on both sides, was randomly assigned for FloSeal application on 1 side of the pelvis. The other side of the pelvis without any product application being the control side. The amount of lymph drainage at each side of the pelvis was measured for 3 days, and computed tomography scans were obtained 7 days and 6 months after surgery for detection of pelvic lymphocele. Among 37 cases, the median amount of lymph drainage was significantly decreased in the hemi-pelvis treated with FloSeal compared to the control hemi-pelvis (p=0.025). The occurrence of lymphocele was considerably reduced in treated hemi-pelvis (8/37, 21.6%) compared with control hemi-pelvis (12/37, 32.4%) after 7 post-operative days (p=0.219), and more decreased in the treated hemi-pelvis (5/37, 13.5%) compared with control hemi-pelvis (9/37, 24.3%) after postoperative 6 months (p=0.344). The application of FloSeal as a tissue sealant in lymph nodes resected tissues can reduce the incidence of pelvic lymphocele in gynecologic cancer patients. A large randomized controlled study could confirm these preliminary results. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology

  4. Performance of a polymer sealant coating in an arctic marine environment

    International Nuclear Information System (INIS)

    Moskowitz, P.; Cowgill, M.; Griffith, A.; Chernaenko, L.; Diashev, A.; Nazarian, A.

    2001-01-01

    The feasibility of using a polymer-based coating, Polibrid 705, to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment has been successfully demonstrated using a combination of field and laboratory testing. A mobile, self-sufficient spraying device was developed to specifications provided by the Russian Northern Navy and deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading dock. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors, exposed to the full annual Arctic weather cycle. The 12 months of field testing gave rise to little degradation of the sealant coating, except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. The field tests were accompanied by a series of laboratory qualification tests carried out at a research laboratory in St. Petersburg. The laboratory tests examined a variety of properties, including bond strength between the coating and the substrate, thermal cycling resistance, wear resistance, flammability, and ease of decontamination. The Polibrid 705 coating met all the Russian Navy qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities

  5. Silver microparticles plus fibrin tissue sealant prevents incisional hernias in rats.

    Science.gov (United States)

    Primus, Frank E; Young, David M; Grenert, James P; Harris, Hobart W

    2018-07-01

    Open abdominal surgery is frequently complicated by the subsequent development of an incisional hernia. Consequently, more than 400,000 incisional hernia repairs are performed each year, adding over $15 billion per year to U.S. health-care expenditures. While the vast majority of studies have focused on improved surgical techniques or prosthetic materials, we examined the use of metallic silver microparticles to prevent incisional hernia formation through enhanced wound healing. A rodent incisional hernia model was used. Eighty-two rats were randomly placed into two control groups (saline alone and silver microparticles alone), and three experimental groups (0 mg/cm, 2.5 mg/cm, and 25 mg/cm of silver microparticles applied with a fibrin sealant). Incisional hernia incidence and size, tensile strength, and tissue histology were assessed after 28 days. A significant reduction of both incisional hernia incidence and hernia size was observed between the control groups and 2.5 mg/cm group, and between the control and 25 mg/cm group by nearly 60% and 90%, respectively (P < 0.05). Histological samples showed a noticeable increase in new fibrosis in the treated animals as compared with the controls, whereas the tensile strength between the groups did not differ. The novel approach of using silver microparticles to enhance wound healing appears to be a safe and effective method to prevent incisional hernias from developing and could herald a new era of medicinal silver use. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. The Ability of the Eating Assessment Tool-10 to Detect Aspiration in Patients With Neurological Disorders

    Science.gov (United States)

    Arslan, Selen Serel; Demir, Numan; Kılınç, Hasan E; Karaduman, Aynur A

    2017-01-01

    Background/Aims Dysphagia is common in patients with neurological disorders. There is a need to identify patients at risk early by a useful clinical tool to prevent its serious complications. The study aims to determine the ability of the Turkish version of Eating Assessment Tool-10 (T-EAT-10) to detect aspiration in patients with neurological disorders. Methods Two hundred fifty-nine patients with neurological disorders who had complaints about swallowing difficulty and referred for a swallowing evaluation were included. Oropharyngeal dysphagia was evaluated with the T-EAT-10 and videofluoroscopic swallowing study in the same day. The penetration-aspiration scale (PAS) was used to document the penetration and aspiration severity. Results The mean age of the patients was 59.72 ± 17.24 years (minimum [min] = 18, maximum [max] = 96), of which 57.1% were male. The mean T-EAT-10 of patients who had aspiration (PAS > 5) was 25.91 ± 10.31 (min = 1, max = 40) and the mean T-EAT-10 of patients who did not have aspiration (PAS < 6) was 15.70 ± 10.54 (min = 0, max = 40) (P < 0.001). Patients with a T-EAT-10 score higher than 15 were 2.4 times more likely to aspirate. A linear correlation was found between T-EAT-10 and PAS scores of the patients (r = 0.416, P < 0.001). The sensitivity of a T-EAT-10 higher than 15 in detecting aspiration was 81.0% and the specificity was 58.0%. A T-EAT-10 score of higher than 15 has a positive predictive value of 72.0% and a negative predictive value of 69.0%. Conclusion The T-EAT-10 can be used to detect unsafe airway protection in neurology clinics to identify and refer dysphagic patients for further evaluation. PMID:28545185

  7. PEMANFAATAN REBUSAN DAUN SIRIH MERAH (Piper crocatum DALAM MENURUNKAN TINGKAT KEJADIAN MASTITIS BERDASARKANN UJI CMT DAN SCC

    Directory of Open Access Journals (Sweden)

    Razan Harastha Sjuhada

    2017-11-01

    Full Text Available The red betel leaves (Piper crocatum known as herbal antiseptic that contain many substances like essential oil, flavonoid, saponin, and tannin. The red betel leaves can be use to replace chemical antiseptic and more safe to use for teat dipping for dairy cow. The purpose of this research was to determine the effect of teat dipping with red betel leaves decoction to decrease subclinical mastitis level and somatic cell based on CMT and SCC. The method in this research was experiment with Randomize Block Design with 3 treatments and 5 replications. The data analyzed with Analysis of Variance (ANOVA, if there were significant effects it would be continue by Duncan’s Multiple Range Test (DMRT. The results showed that teat dipping with red betel leaves decoction had a significant different (P<0.05 to decrease mastitis level. Teat dipping with red betel leaves decoction 20% concentration could decrease mastitis level up to 30%. Teat dipping with red betel leaves decoction had a significant difference (P<0.05 to decrease the amount of somatic cell too. Teat dipping with red betel leaves stew 20% concentration could decrease the amount of somatic cell up to 1.98% or 0.12CFU/ml. The conclusion that teat dipping with red betel leaves decoction 20% was the best concentration and gave the best results to decrease mastitis level and somatic cell.

  8. Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.

    Science.gov (United States)

    Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M

    2013-02-01

    This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner

  9. Milking performance and udder health of cows milked with two different liners

    DEFF Research Database (Denmark)

    Rasmussen, Morten D.; Frimer, Erik S.; Kaartinen, L.

    1998-01-01

    The effects of milking cows with two different liners were measured for a period of 8 months with 115 Danish Holstein cows divided into two groups. G-roup H and L animals were milked with liners with mouthpiece cavity]heights of 30 and 18 mm respectively (other dimensions also differed between...... the two liners). Aver age teat lengths of first lactation cows were 45 and 40 mm for front and rear teats. Older cows had teats similar to 10 min longer. There was no difference in milk yield or milk flow rates between the two groups. Average machine-on time was shorter for group L, and first lactation...... cows of group L were less restive. The frequency of red and blue discoloured teats immediately after milking was higher for group H, and teat length increased on average 5 mm during lactation with no increase for group L. The small overall differences in udder health between the two groups were...

  10. Investigation of Performance of SCN-1 Pure Glass as Sealant Used in SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenning N.; Sun, Xin; Stephens, Elizabeth V.; Khaleel, Mohammad A.

    2010-03-01

    As its name implies, self-healing glass seal has the potential of restoring its mechanical properties upon being reheated to stack operating temperature, even when it has experienced some cooling induced damage/crack at room temperature. Such a self-healing feature is desirable for achieving high seal reliability during thermal cycling. On the other hand, self-healing glass is also characterized by its low mechanical stiffness and high creep rate at the typical operating temperature of SOFCs. Therefore, from a design’s perspective, it is important to know the long term geometric stability and thermal mechanical behaviors of the self-healing glass under the stack operating conditions. These predictive capabilities will guide the design and optimization of a reliable sealing system that potentially utilizes self-healing glass as well as other ceramic seal components in achieving the ultimate goal of SOFC. In this report, we focused on predicting the effects of various generic seal design parameters on the stresses in the seal. For this purpose, we take the test cell used in the leakage test for compliant glass seals conducted in PNNL as our initial modeling geometry. The effect of the ceramic stopper on the geometry stability of the self-healing glass sealants is studied first. Then we explored the effect of various interfaces such as stopper and glass, stopper and PEN, as well stopper and IC plate, on the geometry stability and reliability of glass during the operating and cooling processes.

  11. Evaluation of a fissure sealant program as part of community-based teaching and training.

    Science.gov (United States)

    van Wyk, Philippus J; Kroon, Jeroen; White, John G

    2004-01-01

    Since 1995 the Department of Community Dentistry of the University of Pretoria has been involved in the rendering of mobile primary oral health care services to children in the Hammanskraal area of Gauteng, South Africa, as part of their students' community-based training. Mokonyama Primary School was identified as the first school where a primary oral health care service could be rendered. The objective of this study was to evaluate the impact (outcomes) of a fissure sealant program on the dentition status of the school children. Seven years after the implementation of the program, the dentition status of children at Mokonyama was compared with that of a comparable group of children from the same area who were not exposed to the program. The results showed that the decayed, missing, and filled teeth in the primary dentition (dmft) in the six-year-old group in Mokonyama (1.74) did not differ significantly from the dmft (1.43) of the control group (p = 0.49). The decayed, missing, and filled teeth in the permanent dentition (DMFT) of 0.59 for the fifteen-year-old group in Mokonyama, however, differed significantly (p = 0.0001) from the DMFT of the control group (2.38). Fifteen-year-old children in Mokonyama had 75.2 percent fewer caries than their counterparts in the control group.

  12. Development and characterization of glass-ceramic sealants in the (CaO-Al2O3-SiO2-B2O3) system for Solid Oxide Electrolyzer Cells

    International Nuclear Information System (INIS)

    Khedim, Hichem; Nonnet, Helene; Mear, Francois O.

    2012-01-01

    The efficiency of glass-ceramic sealants plays a crucial role in Solid Oxide Electrolyzer Cell performance and durability. In order to develop suitable sealants, operating around 800 degrees C, two parent glass compositions, CAS1B and CAS2B, from the CaO-Al 2 O 3 -SiO 2 -B 2 O 3 system were prepared and explored. The thermal and physicochemical properties of the glass ceramics and their crystallization behavior were investigated by HSM. DTA and XRD analyses. The microstructure and chemical compositions of the crystalline phases were investigated by microprobe analysis. Bonding characteristic as well as chemical interactions of the parent glass with yttria-stabilized zirconia (YSZ) electrolyte and ferritic steel-based interconnect (Crofere (R)) were also investigated. The preliminary results revealed the superiority of CAS2B glass for sealing application in SOECs. The effect of minor additions of V 2 O 5 , K 2 O and TiO 2 on the thermal properties was also studied and again demonstrated the advantages of the CAS2B glass composition. Examining the influence of heat treatment on the seal behavior showed that the choice of the heating rate is a compromise between delaying the crystallization process and delaying the viscosity drop. The thermal Expansion Coefficients (TEC) obtained for the selected glass ceramic are within the desired range after the heat treatment of crystallization. The crystallization kinetic parameters of the selected glass composition were also determined under non-isothermal conditions by means of differential thermal analysis (DTA) and using the formal theory of transformations for heterogeneous nucleation. (authors)

  13. Mode of action and in vitro susceptibility of mastitis pathogens to macedocin ST91KM and preparation of a teat seal containing the bacteriocin

    Directory of Open Access Journals (Sweden)

    Renee Pieterse

    2010-03-01

    Full Text Available Mastitis is considered to be the most economically costly disease affecting the dairy industry. Regular dosage of animals with antibiotics, including use of prophylactic concentrations, may select for resistant strains. The purpose of this study was to determine the mode of action of a new bacteriocin (macedocin ST91KM, to evaluate the antimicrobial resistance of mastitis pathogens to antibiotics commonly used in treatment remedies, and to introduce the possible use of an alternative antimicrobial agent. The bacteriocin macedocin ST91KM, produced by Streptococcus gallolyticus subsp. macedonicus ST91KM, is bactericidal to Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis and Staphylococcus aureus associated with mastitis infections, including strains resistant to methicillin and oxacillin. Sensitive cells were deformed and secreted nucleotides, K+ and β-galactosidase when exposed to macedocin ST91KM. Adsorption of the peptide to target cells decreased in the presence of solvents, suggesting that receptors on the cell surfaces have lipid moieties. No adsorption was recorded in the presence of MgCl2, KI and Na2CO3, suggesting that ionic strength plays an important role. A teat seal preparation containing macedocin ST91KM effectively released the peptide and inhibited the growth of S. agalactiae. Macedocin ST91KM could form the basis for alternative dry cow therapy to prevent mastitis infections in dairy cows as it is effective against pathogens that display resistance to conventional antibiotic therapy.

  14. Non-genetic factors of udder morphology traits in Istrian ewes

    Directory of Open Access Journals (Sweden)

    Valentino Držaić

    2013-05-01

    Full Text Available Considering the facts that Istrian sheep is Croatian indigenous breed with the highest milk production, and increasing interest of local farmers for machine milking implementation, the aim of this study was to determine the factors affecting udder morphology traits of Istrian ewes. Ninetythree purebred Istrian ewes with symmetrical udders and no signs of clinical mastitis, from second to fourth lactation, were used for this study. Average udder depth of Istrian ewes was 15.85 cm, udder width 13.05 cm, udder circumference 39.66 cm, cistern height 1.44 cm, teat position 2.85 (scored from 1 to 5, teat angle 47.32°, teat length 3.43 cm and teat width 2.03 cm. The traits related to udder size (depth, width, and circumference were significantly (P<0.01 affected by lactation milk yield. These traits were also in high and positive correlations (P<0.01 with daily milk yield. With the increase of parity, the morphological aptitude of udder to mechanical milking become worse, with an increase (P<0.01 of cistern height, teat angle and position. As lactation of Istrian ewes continued morphological traits defining udder aptitude for machine milking improved (decrease of cistern height, teat angle and position. Ewes with two and more lambs had larger udder (P<0.05 than ewes with a single lamb.

  15. Wound healing and degradation of the fibrin sealant Beriplast P following partial liver resection in rabbits.

    Science.gov (United States)

    Kroez, Monika; Lang, Wiegand; Dickneite, Gerhard

    2005-01-01

    The objective of this study was to investigate the degradation kinetics of the fibrin sealant (FS) Beriplast P in an experimental liver surgery model in rabbits. A partial liver resection was performed in 21 rabbits, and the wound area covered with Beriplast P to ensure hemostasis. Wound healing of the resection sites was evaluated morphologically over 11 weeks. Degradation of the FS was evaluated by measuring the thickness of the remaining fibrin layer. Plasma samples were analyzed for antibodies against fibrinogen, albumin, thrombin, fibrin, and factor XIII. No postoperative hemorrhage was observed, indicating successful hemostasis throughout. The FS was degraded with a half-life of about 25 days postapplication and was completely replaced by granulation tissue within 9 weeks. The FS degradation and tissue development followed the general stages of wound healing: inflammation and resorption, proliferation, organization and production of collagen, maturation, and scarring. An immune reaction was elicited against the main four human proteins of the FS. The antibody titers peaked on day 14, with a gradual decrease thereafter. We conclude that the FS accomplished hemostasis, facilitated healing in accordance with natural processes, and was completely degraded over time. In humans, the reduced immunogenicity of the FS would potentially increase its degradation half-life.

  16. Final environmental and regulatory assessment of using asphalt as a sealant in mine shafts

    International Nuclear Information System (INIS)

    1987-01-01

    This report discusses the properties of asphalt, the current regulatory status governing asphalt and future regulatory implications which may be pertinent in using asphalt as a waterproof shaft sealant. An understanding of the inherent organic composition of asphalt, an increase in the number of health and environmental research publications conducted on asphalt and an examination of the apparent trend of regulatory agencies toward more stringent environmental regulation governing the use of organic materials suggests asphalt could become regulated at a future time. This would only occur, however, if asphalt was found to conform to the present regulatory definitions of pollutants, contaminants or hazardous substances or if asphalt was included on a regulated substance list. In this regard, the study points out that asphalt contains very low levels of hazardous poly-nuclear aromatics (PNA's). These levels are significantly lower than the levels present in coal tars, a substance known to contain high levels of hazardous PNA's. Asphalt, however, has the inherent potential of producing higher concentrations of PNA's if the adverse condition of cracking should occur during the refinery production stage or on-site preparation of the asphalt. Also, unless existing control technology is applied, emission levels of sulfur dioxide, carbon monoxide, particulates and volatile organic carbons from the on-site preparation facilities could approach the permissible health standard levels of EPA. The study indicates, however, that available literature is limited on these issues

  17. Herd characteristics and cow-level factors associated with Prototheca mastitis on dairy farms in Ontario, Canada.

    Science.gov (United States)

    Pieper, L; Godkin, A; Roesler, U; Polleichtner, A; Slavic, D; Leslie, K E; Kelton, D F

    2012-10-01

    Prototheca spp. are algae that cause incurable acute or chronic mastitis in dairy cows. The aim of this case-control study was the identification of cow- and herd-level risk factors for this unusual mastitis pathogen. Aseptically collected composite milk samples from 2,428 milking cows in 23 case and 23 control herds were collected between January and May 2011. A questionnaire was administered to the producers, and cow-level production and demographic data were gathered. In 58 of 64 isolates, Prototheca spp. and Prototheca zopfii genotypes were differentiated using PCR and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. All isolates were identified as Prototheca zopfii genotype 2. The mean within-herd prevalence for Prototheca spp. was 5.1% (range 0.0-12.5%). Case herds had a significantly lower herd-level prevalence of Staphylococcus aureus and a higher prevalence of yeasts than did control herds. The final logistic regression model for herd-level risk factors included use of intramammary injections of a non-intramammary drug [odds ratio (OR) = 136.8], the number of different injectable antibiotic products being used (OR = 2.82), the use of any dry cow teat sealant (external OR = 80.0; internal OR = 34.2), and having treated 3 or more displaced abomasums in the last 12 mo OR = 44.7). The final logistic regression model for cow-level risk factors included second or greater lactation (OR = 4.40) and the logarithm of the lactation-average somatic cell count (OR = 2.99). Unsanitary or repeated intramammary infusions, antibiotic treatment, and off-label use of injectable drugs in the udder might promote Prototheca udder infection. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    Science.gov (United States)

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p 30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  19. Free volume of mixed cation borosilicate glass sealants elucidated by positron annihilation lifetime spectroscopy and its correlation with glass properties

    Science.gov (United States)

    Ojha, Prasanta K.; Rath, Sangram K.; Sharma, Sandeep K.; Sudarshan, Kathi; Pujari, Pradeep K.; Chongdar, Tapas K.; Gokhale, Nitin M.

    2015-01-01

    The role of La+3/Sr+2 ratios, which is varied from 0.08 to 5.09, on density, molar volume, packing fraction, free volume, thermal and electrical properties in strontium lanthanum aluminoborosilicate based glass sealants intended for solid oxide fuel cell (SOFC) applications is evaluated. The studies reveal expansion of the glass network evident from increasing molar volume and decreasing packing fraction of glasses with progressive La+3 substitutions. The molecular origin of these macroscopic structural features can be accounted for by the free volume parameters measured from positron annihilation lifetime spectroscopy (PALS). The La+3 induced expanded glass networks show increased number of subnanoscopic voids with larger sizes, as revealed from the ortho-positronium (o-Ps) lifetime and its intensity. A remarkably direct correspondence between the molar volume and fractional free volume trend is established with progressive La2O3 substitution in the glasses. The effect of these structural changes on the glass transition temperature, softening temperature, coefficient of thermal expansion, thermal stability as well as electrical conductivity has been studied.

  20. The Use of Pit and Fissure Sealants—A Literature Review

    Directory of Open Access Journals (Sweden)

    Reem Naaman

    2017-12-01

    Full Text Available This paper reviews the literature and discusses the latest updates on the use of pit and fissure sealants. It demonstrates the effectiveness of pit and fissure sealants in preventing caries and the management of early carious lesions. It compares the use of different sealant materials and their indications. It describes the application technique for sealants. It also reviews the cost-effectiveness of sealants as a preventive strategy. From this review and after the discussion of recently published studies on pit and fissure sealants, it is evident that sealants are effective in caries prevention and in preventing the progression of incipient lesions. It is therefore recommended that pit and fissure sealant be applied to high-caries-risk children for optimum cost-effectiveness. It is a highly sensitive technique that needs optimum isolation, cleaning of the tooth surface, etching, and the application of a thin bonding layer for maximum benefit. Recall and repair, when needed, are important to maximize the effectiveness of such sealant use.

  1. The Use of Pit and Fissure Sealants—A Literature Review

    Science.gov (United States)

    Naaman, Reem; El-Housseiny, Azza A.; Alamoudi, Najlaa

    2017-01-01

    This paper reviews the literature and discusses the latest updates on the use of pit and fissure sealants. It demonstrates the effectiveness of pit and fissure sealants in preventing caries and the management of early carious lesions. It compares the use of different sealant materials and their indications. It describes the application technique for sealants. It also reviews the cost-effectiveness of sealants as a preventive strategy. From this review and after the discussion of recently published studies on pit and fissure sealants, it is evident that sealants are effective in caries prevention and in preventing the progression of incipient lesions. It is therefore recommended that pit and fissure sealant be applied to high-caries-risk children for optimum cost-effectiveness. It is a highly sensitive technique that needs optimum isolation, cleaning of the tooth surface, etching, and the application of a thin bonding layer for maximum benefit. Recall and repair, when needed, are important to maximize the effectiveness of such sealant use. PMID:29563440

  2. Effect of presampling procedures on real-time PCR used for diagnosis of intramammary infections with Staphylococcus aureus in dairy cows at routine milk recordings

    DEFF Research Database (Denmark)

    Mahmmod, Yasser; Klaas, Ilka Christine; Nielsen, Søren Saxmose

    2013-01-01

    the farmers' routine premilking preparations, 624 cows of the 1,199 cows were randomly selected for bacterial culture preceded by presampling procedures. These procedures were: cleaning of udder teats, removing the first streams of milk, and 70% alcohol teat disinfection. Data on parity, somatic cell counts...

  3. Protocol for “Seal or Varnish?” (SoV trial: a randomised controlled trial to measure the relative cost and effectiveness of pit and fissure sealants and fluoride varnish in preventing dental decay

    Directory of Open Access Journals (Sweden)

    Chestnutt Ivor Gordon

    2012-11-01

    Full Text Available Abstract Background Dental caries remains a significant public health problem, prevalence being linked to social and economic deprivation. Occlusal surfaces of first permanent molars are the most susceptible site in the developing permanent dentition. Cochrane reviews have shown pit and fissure sealants (PFS and fluoride varnish (FV to be effective over no intervention in preventing caries. However, the comparative cost and effectiveness of these treatments is uncertain. The primary aim of the trial described in this protocol is to compare the clinical effectiveness of PFS and FV in preventing dental caries in first permanent molars in 6-7 year-olds. Secondary aims include: establishing the costs and the relative cost-effectiveness of PFS and FV delivered in a community/school setting; examining the impact of PFS and FV on children and their parents/carers in terms of quality of life/treatment acceptability measures; and examining the implementation of treatment in a community setting. Methods/design The trial design comprises a randomised, assessor-blinded, two-arm, parallel group trial in 6–7 year old schoolchildren. Clinical procedures and assessments will be performed at 66 primary schools, in deprived areas in South Wales. Treatments will be delivered via a mobile dental clinic. In total, 920 children will be recruited (460 per trial arm. At baseline and annually for 36 months dental caries will be recorded using the International Caries Detection and Assessment System (ICDAS by trained and calibrated dentists. PFS and FV will be applied by trained dental hygienists. The FV will be applied at baseline, 6, 12, 18, 24 and 30 months. The PFS will be applied at baseline and re-examined at 6, 12, 18, 24, and 30 months, and will be re-applied if the existing sealant has become detached/is insufficient. The economic analysis will estimate the costs of providing the PFS versus FV. The process evaluation will assess implementation and

  4. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States); Ensor, Joe E. [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Mahvash, Armeen; Sabir, Sharjeel H.; Steele, Joseph R.; McRae, Stephen E.; Avritscher, Rony; Huang, Steven Y.; Odisio, Bruno C.; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J.; Tam, Alda L. [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  5. Coating of Dacron vascular grafts with an ionic polyurethane: a novel sealant with protein binding properties.

    Science.gov (United States)

    Phaneuf, M D; Dempsey, D J; Bide, M J; Quist, W C; LoGerfo, F W

    2001-03-01

    The purpose of this study was to develop a novel sealant that would seal prosthetic vascular graft interstices and be accessible for protein binding. Crimped knitted Dacron vascular grafts were cleaned (CNTRL) and hydrolyzed in boiling sodium hydroxide (HYD). These HYD grafts were sealed using an 11% solids solution of a polyether-based urethane with carboxylic acid groups (PEU-D) via a novel technique that employs both trans-wall and luminal perfusion. Carboxylic acid content, determined via methylene blue dye uptake, was 2.3- and 4.2-fold greater in PEU-D segments (1.0+/-0.27 nmol/mg) as compared to HYD and CNTRL segments, respectively. Water permeation through PEU-D graft (1.1+/-2 ml/cm2 min(-1)) was comparable to collagen-impregnated Dacron (9.8+/-10 ml/cm2 min(-1)). Non-specific 125I-albumin (125I-Alb) binding to PEU-D segments (18+/-3 ng/mg) was significantly lower than HYD and CNTRL segments. 125I-Alb linkage to PEU-D using the crosslinker EDC resulted in 5.7-fold greater binding (103+/-2 ng/mg) than non-specific PEU-D controls. However, covalent linkage of 125I-Alb to PEU-D was 4.9- and 5.9-fold less than CNTRL and HYD segments with EDC, respectively. Thus, ionic polyurethane can be applied to a pre-formed vascular graft, seal the interstices and create "anchor" sites for protein attachment.

  6. Synaptic plasticity and sensory-motor improvement following fibrin sealant dorsal root reimplantation and mononuclear cell therapy

    Science.gov (United States)

    Benitez, Suzana U.; Barbizan, Roberta; Spejo, Aline B.; Ferreira, Rui S.; Barraviera, Benedito; Góes, Alfredo M.; de Oliveira, Alexandre L. R.

    2014-01-01

    Root lesions may affect both dorsal and ventral roots. However, due to the possibility of generating further inflammation and neuropathic pain, surgical procedures do not prioritize the repair of the afferent component. The loss of such sensorial input directly disturbs the spinal circuits thus affecting the functionality of the injuried limb. The present study evaluated the motor and sensory improvement following dorsal root reimplantation with fibrin sealant (FS) plus bone marrow mononuclear cells (MC) after dorsal rhizotomy. MC were used to enhance the repair process. We also analyzed changes in the glial response and synaptic circuits within the spinal cord. Female Lewis rats (6–8 weeks old) were divided in three groups: rhizotomy (RZ group), rhizotomy repaired with FS (RZ+FS group) and rhizotomy repaired with FS and MC (RZ+FS+MC group). The behavioral tests electronic von-Frey and Walking track test were carried out. For immunohistochemistry we used markers to detect different synapse profiles as well as glial reaction. The behavioral results showed a significant decrease in sensory and motor function after lesion. The reimplantation decreased glial reaction and improved synaptic plasticity of afferent inputs. Cell therapy further enhanced the rewiring process. In addition, both reimplanted groups presented twice as much motor control compared to the non-treated group. In conclusion, the reimplantation with FS and MC is efficient and may be considered an approach to improve sensory-motor recovery following dorsal rhizotomy. PMID:25249946

  7. Disinfectant effect of Methylated Ethanol against Listeria species

    Directory of Open Access Journals (Sweden)

    Y Yakubu

    2012-04-01

    Full Text Available This study was carried out in order to determine the disinfectant effect of Methylated spirit® (95% methanol and 5% ethanol as a teat dip against Listeria species. Hand milking was employed to collect 576 (288 x 2 raw milk samples from different lactating cows within Sokoto metropolis (Nigeria. 288 samples were collected before disinfecting the udder teats with Methylated spirit®, while the other 288 were collected after disinfection with Methylated spirit®. The samples were analyzed using selective culture and isolation technique in which the 288 samples collected before disinfection, 114 (39.6% were positive for Listeria species. Among the positive samples 44 (38.6% were Listeria innocua, 16 (14.0% Listeria ivanovii, 36 (31.6% Listeria monocytogenes, 11 (9.6% Listeria welshimeri and 7 (6.1% Listeria seeligeri, while none of the 288 samples collected after disinfection was positive. The study has shown high prevalence of Listeria species in milk collected without washing/disinfecting the teats and has also established the sensitivity of Listeria species to methylated ethanol which can be used as dip for disinfecting udder teats before milking in order to prevent contamination with Listeria species and other methylated spirit-sensitive organisms. This study is essential to educate Fulani herdsmen and other milk handlers on the importance of disinfecting udder teats before milking. [Vet. World 2012; 5(2.000: 91-93

  8. Quarter and cow risk factors associated with the occurrence of clinical mastitis in dairy cows in the United Kingdom.

    Science.gov (United States)

    Breen, J E; Green, M J; Bradley, A J

    2009-06-01

    Quarter and cow risk factors associated with the development of clinical mastitis (CM) during lactation were investigated during a 12-mo longitudinal study on 8 commercial Holstein-Friesian dairy farms in the southwest of England. The individual risk factors studied on 1,677 cows included assessments of udder and leg hygiene, teat-end callosity, and hyperkeratosis; body condition score; and measurements of monthly milk quality and yield. Several outcome variables for CM were used for statistical analysis, which included use of generalized linear mixed models. Significant covariates associated with an increased risk of CM were increasing parity, decreasing month of lactation, cows with very dirty udders, and quarters with only very severe hyperkeratosis of the teat-end. Thin and moderate smooth teat-end callosity scores were not associated with an increased risk for CM. Cows that recorded a somatic cell count >199,000 cells/mL and a milk protein percentage cow body condition score and incidence of CM. Of the cases of CM available for culture, 171 (26.7%) were confirmed as being caused by Escherichia coli and 121 (18.9%) confirmed as being caused by Streptococcus uberis. Quarters with moderate and very severe hyperkeratosis of the teat-end were at significantly increased risk of clinical E. coli mastitis before the next visit. Quarters with very severe hyperkeratosis of the teat-end were significantly more likely to develop clinical Strep. uberis mastitis before the next visit. There were strong trends within the data to suggest an association between very dirty udders (an increased risk of clinical E. coli mastitis) and teat-ends with no callosity ring present (an increased risk of clinical Strep. uberis mastitis). These results highlight the importance of individual quarter- and cow-level risk factors in determining the risk of CM associated with environmental pathogens during lactation.

  9. Effect of irradiation times on the polymerization depth of contemporary fissure sealants with different opacities

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2011-04-01

    Full Text Available The aim of this study was to evaluate the depth of curing of 10 contemporary blue light-activated dental flowable materials at several opacities, influenced by different irradiation times using FT-IR spectroscopy. Fifty-five specimens (n = 5 with a 5-mm diameter and 1-mm thickness of translucent (Opallis Flow T, yellowed (Master Flow A2; Opallis Flow A2; Natural Flow A2; Fluroshield Yellowed, and opaque materials (Master Flow OA2; Natural Flow O; Opallis Flow OA3.5; Opallis Flow OP; Fluroshield White were obtained at six curing times (10s, 20s, 30s, 40s, 50s, and 60s using a high-intensity LED (Coltolux, Coltène/Whaledent. The degree of conversion (DC (% was obtained using the Nexus 470 FTIR Spectrometer (Nicolet Instruments, USA. The FTIR-ATR spectra for uncured and cured samples were analyzed using a ZnSe crystal. The top and bottom surfaces of the cured specimens were analyzed to obtain the depth of curing. Two-way ANOVA was used to analyze the data. The highest curing depth was obtained by Natural Flow OA2, while the lowest was shown by Master Flow OA2. The shortest curing time generated similar depths of cure in comparison with the most extensive for Opallis Flow A2 and Fluroshield Yellowed. Therefore, depth of curing, influenced by the irradiation time, was dependent on the materials. Using the Natural Flow OA2 opaque sealant and the 10-s curing time for Opallis Flow A2 and Fluroshield Yellowed may represent alternative approaches to sealing tooth fissures.

  10. Influence of udder stimulation, stage of lactation and parity on milk ...

    African Journals Online (AJOL)

    Influence of udder stimulation, stage of lactation and parity on milk yield in West African Dwarf goats. ... Left teat of the does produced significantly (P<0.05) more milk than the right teat. Therefore, it is recommended that goats udder in higher parity be stimulated prior to milking at early stage of lactation for higher milk ...

  11. Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy.

    Science.gov (United States)

    Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M

    2018-01-01

    Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.

  12. Estimation of Genetic and Phenotypic Parameters for Udder Morphology Traits in Different Dairy Sheep Genotypes

    Directory of Open Access Journals (Sweden)

    Pavol Makovický

    2017-01-01

    Full Text Available Knowledge of genetic parameters is the basis of sound livestock improvement programmes. Genetic parameters have been estimated for linear udder traits: Udder depth (UD, Cistern depth (CD, Teat position (TP, Teat size (TS and external udder measurements: Rear udder depth (RUD, Cistern depth (CDe, Teat length (TL and Teat angle (TA – 1275 linear assessments (381 ewes and 1185 external udder measurements (355 ewes were included in the analysis for each character of 9 genotypes. Nine breeds and genotypes were included in these experiments: purebred Improved Valachian (IV, Tsigai (T, Lacaune (LC ewes, and IV and T crosses with genetic portion of Lacaune and East Friesian (EF – 25 %, 50 % and 75 %. Primary data were processed using restricted maximum likelihood (REML methodology and the multiple‑trait animal model, using programs REMLF90 and VCE 4.0. High genetic correlations were found between UD and RUD (0.86, CD and CD(e (0.93, TP and TA (0.90, TS and TL (0.94. The highest heritabilities were estimated for exact measurements of TL and CD (0.35–0.39 and subjectively assessed TA and TS (0.32 – 0.33.

  13. 3D vision system for intelligent milking robot automation

    Science.gov (United States)

    Akhloufi, M. A.

    2013-12-01

    In a milking robot, the correct localization and positioning of milking teat cups is of very high importance. The milking robots technology has not changed since a decade and is based primarily on laser profiles for teats approximate positions estimation. This technology has reached its limit and does not allow optimal positioning of the milking cups. Also, in the presence of occlusions, the milking robot fails to milk the cow. These problems, have economic consequences for producers and animal health (e.g. development of mastitis). To overcome the limitations of current robots, we have developed a new system based on 3D vision, capable of efficiently positioning the milking cups. A prototype of an intelligent robot system based on 3D vision for real-time positioning of a milking robot has been built and tested under various conditions on a synthetic udder model (in static and moving scenarios). Experimental tests, were performed using 3D Time-Of-Flight (TOF) and RGBD cameras. The proposed algorithms permit the online segmentation of teats by combing 2D and 3D visual information. The obtained results permit the teat 3D position computation. This information is then sent to the milking robot for teat cups positioning. The vision system has a real-time performance and monitors the optimal positioning of the cups even in the presence of motion. The obtained results, with both TOF and RGBD cameras, show the good performance of the proposed system. The best performance was obtained with RGBD cameras. This latter technology will be used in future real life experimental tests.

  14. Stable glass-ceramic sealants for solid oxide fuel cells: Influence of Bi{sub 2}O{sub 3} doping

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Ashutosh; Ferreira, Jose M.F. [Department of Ceramics and Glass Engineering, University of Aveiro, CICECO, 3810-193 Aveiro (Portugal); Pascual, Maria J. [Instituto de Ceramica y Vidrio (CSIC), Kelsen 5, Campus de Cantoblanco, 28049 Madrid (Spain)

    2010-07-15

    Diopside (CaMgSi{sub 2}O{sub 6}) based glass-ceramics in the system SrO-CaO-MgO-Al{sub 2}O{sub 3}-B{sub 2}O{sub 3}-La{sub 2}O{sub 3}-Bi{sub 2}O{sub 3}-SiO{sub 2} have been synthesized for sealing applications in solid oxide fuel cells (SOFC). The parent glass composition in the primary crystallization field of diopside has been doped with different amounts of Bi{sub 2}O{sub 3} (1, 3, 5 wt.%). The sintering behavior by hot-stage microscopy (HSM) reveals that all the investigated glass compositions exhibit a two-stage shrinkage behavior. The crystallization kinetics of the glasses has been studied by differential thermal analysis (DTA) while X-ray diffraction adjoined with Rietveld-R.I.R. analysis have been employed to quantify the amount of crystalline and amorphous phases in the glass-ceramics. Diopside and augite crystallized as the primary crystalline phases in all the glass-ceramics. The coefficient of thermal expansion (CTE) of the investigated glass-ceramics varied between (9.06-10.14) x 10{sup -6} K{sup -1} after heat treatment at SOFC operating temperature for a duration varying between 1 h and 200 h. Further, low electrical conductivity, good joining behavior and negligible reactivity with metallic interconnects (Crofer22 APU and Sanergy HT) in air indicate that the investigated glass-ceramics are suitable candidates for further experimentation as sealants in SOFC. (author)

  15. An essential primer for understanding the role of topical hemostats, surgical sealants, and adhesives for maintaining hemostasis.

    Science.gov (United States)

    Gabay, Michael; Boucher, Bradley A

    2013-09-01

    A wide variety of topical hemostats are approved as adjunctive therapies in the maintenance of hemostasis during surgical procedures in which conventional methods are insufficient or not practical. A multidisciplinary approach to the selection and application of these agents requires input from all members of the surgical team including surgeons, perioperative nurses, blood bank specialists, and pharmacists. However, pharmacist knowledge regarding topical hemostats may be limited based on lack of formal education within college of pharmacy curricula as well as their use being predominantly in the operating room setting. Furthermore, some of these agents might be procured through central supply rather than the hospital pharmacy. Topical hemostats include agents that act as a mechanical barrier to bleeding and provide a physical matrix for clotting, biologically active agents that catalyze coagulation, combination therapies, and synthetic sealants and adhesives. Although many of the topical hemostats were approved for use before the requirement for clinical trials, this review provides an overview of the available clinical evidence regarding the appropriate uses and safety considerations associated with these agents. Proper use of these agents is vital to achieving the best clinical outcomes. Specifically, knowledge of the contraindications and potential adverse events associated with topical hemostats can help prevent unwanted outcomes. Therefore, an understanding of the benefits and potential risks associated with these agents will allow hospital pharmacists to assist in the development and implementation of institutional policies regarding the safe and effective use of hemostatic agents commonly used in the surgical suite. © 2013 Pharmacotherapy Publications, Inc.

  16. 77 FR 59090 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and...

    Science.gov (United States)

    2012-09-26

    ... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... manufacture, sale, use, or application of adhesives, sealants, primers, and solvents. The SIP revision also... proposed rulemaking (NPR) which proposed approval of Pennsylvania's adhesives and sealants regulations in...

  17. 76 FR 53369 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and...

    Science.gov (United States)

    2011-08-26

    ... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... volatile organic compounds (VOC) from the manufacture, sale, use, or application of adhesives, sealants... the adhesive, sealant, primer, and solvent product categories regulated under section 129.77 and...

  18. Atraumatic restorative treatment and minimal intervention dentistry.

    Science.gov (United States)

    Frencken, J E

    2017-08-11

    Too many people worldwide suffer from the consequences of untreated dentine carious lesions. This finding reflects the inability of the currently used traditional mode of treatments to manage such lesions. A change is needed. Dental training institutions should depart from the traditional 'drill and fill' treatments and embrace the holistic oral healthcare approach that is minimal intervention dentistry (MID) and includes within it minimally invasive operative skills. Dental caries is, after all, a preventable disease. The atraumatic restorative treatment (ART) concept is an example of MID. ART consists of a preventive (ART sealant) and a restorative (ART restoration) component. ART sealants using high-viscosity glass-ionomer (HVGIC) have a very high dentine carious lesion preventive effect. The survival rate of these sealants is not significantly different from that of sealants produced with resin. The survival rate of ART/HVGIC restorations matches those of amalgam and resin composite in single- and multiple-surface cavities in primary teeth and in single-surface cavities in permanent teeth. The principles of carious tissue removal within a cavity recommended by the International Caries Consensus Collaboration are in line with those of treating a cavity using ART. Owing to its good performance and the low levels of discomfort/pain and dental anxiety associated with it, ART and/or other evidence-based atraumatic care procedures should be the first treatment for a primary dentine carious lesion. Only if the use of ART is not indicated should other more invasive and less-atraumatic care procedures be used in both primary and permanent dentitions.

  19. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Conlin, Francis [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holloway, Parker [National Renewable Energy Lab. (NREL), Golden, CO (United States); Podorson, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Varshney, Kapil [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  20. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Conlin, F. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Holloway, Parker [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Podorson, David [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Varshney, Kapil [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  1. Evaluation of free-stall mattress bedding treatments to reduce mastitis bacterial growth

    Energy Technology Data Exchange (ETDEWEB)

    Kristula, M A; Dou, Z; Toth, J D; Smith, B I; Harvey, N; Sabo, M [University of Penn, Kennett Square, PA (United States)

    2008-05-15

    Bacterial counts were compared in free-stall mattresses and teat ends exposed to 5 treatments in a factorial study design on 1 dairy farm. Mattresses in five 30-cow groups were subjected to 1 of 5 bedding treatments every other day: 0.5 kg of hydrated limestone, 120 mL of commercial acidic conditioner, 1 kg of coal fly ash, 1 kg of kiln-dried wood shavings, and control (no bedding). Counts of coliforms, Klebsiella spp., Escherichia coli, and Streptococcus spp. were lowest on mattresses bedded with lime. Mattresses bedded with the commercial acidic conditioner had the next lowest counts for coliforms, Klebsiella spp., and Streptococcus spp. Wood shavings and the no-bedding control had the highest counts for coliform and Klebsiella spp. Compared with wood shavings or control, fly ash reduced the counts of coliforms, whereas for the other 3 bacterial groups, the reduction was not always significant. Streptococcus spp. counts were greatest in the control group and did not differ among the shavings and fly ash groups. Teat swab results indicated that hydrated lime was the only bedding treatment that significantly decreased the counts of both coliforms and Klebsiella spp. There were no differences in Streptococcus spp. numbers on the teats between any of the bedding treatments. Bacterial populations grew steadily on mattresses and were generally higher at 36 to 48 h than at 12 to 24 h, whereas bacterial populations on teats grew rapidly by 12 h and then remained constant. Hydrated lime was the only treatment that significantly reduced bacterial counts on both mattresses and teat ends, but it caused some skin irritation.

  2. Jumlah bakteri Staphylococcus aureus dan skor California Mastitis Test (CMT pada susu kambing Peranakan Etawa akibat dipping ekstrak daun Babadotan (Ageratum conyzoides L.

    Directory of Open Access Journals (Sweden)

    Dwi Priono

    2016-04-01

    Full Text Available The aim of this research is to determine the effect of teat dipping of Ettawa crossbred goat using babadotan leaves (Ageratum conyzoides Linn. extract on the number of Staphylococcus aureusin milk. The udder inflammation degree also was determined using California Mastitis Test (CMT. The treatments were post milking teat dipping using antiseptic solutions containing 1%, 3%, and 5% of babadotan leaves extract (T1, T2 and T3, respectively. Milk samples were collected at before treatment (H0 and on the day 3, 6 and 9 day of the treatments (H3, H6 and H9, respectively. Commercially antiseptic povidone iodine was used as positive control (K+. Experimental research design was completely randomized design (CRD split plot types, with the different extract concentration as the main plot and the day of treatment as subplot. CMT scores was analyzed using Kruskal-Wallis test. The results showed that babadotan leaves extract 5% had the same effectiveness (p>0,05 with povidone iodine to reduce the number of Staphylococcus aureusin milk. All extract concentrations (1%, 3% and 5% had the same effectiveness (H>c0,05(3 to decrease the CMT scores by postmilking teat dip treatments for 9 days. Keywords:Teat dipping, Ageratum conyzoides (L., Staphylococcus aureus, CMT score

  3. Disinfectant effect of Methylated Ethanol against Listeria species

    OpenAIRE

    Y Yakubu; M D Salihu; O O Faleke; M B Abubakar; A A Magaji,A U Junaidu

    2012-01-01

    This study was carried out in order to determine the disinfectant effect of Methylated spirit® (95% methanol and 5% ethanol) as a teat dip against Listeria species. Hand milking was employed to collect 576 (288 x 2) raw milk samples from different lactating cows within Sokoto metropolis (Nigeria). 288 samples were collected before disinfecting the udder teats with Methylated spirit®, while the other 288 were collected after disinfection with Methylated spirit®. The ...

  4. Descriptive Summaries of the Research Development Test & Evaluation. Army Appropriation Fiscal Year 1984. Supporting Data Fiscal Year 1984 Budget Estimate Submitted to Congress--February 1983. Volume II.

    Science.gov (United States)

    1983-02-01

    with the functional segmnents of the Army Comnmand. Control Subordinate System Architeture . Analyses within each section adgste functional/cperational...scwded for ta yew. The fund for ths proect mine not proportional to the number of taste because idvdW teat coats vany widely (e.g one teat may raquire...costs of conducting the tests scheduled for that year and are not proportional to the number of test scheduled because Ves of Indidual tests vary widely

  5. Relationship between udder morphology traits, alveolar and cisternal milk compartments and machine milking performances of dairy camels (Camelus dromedarius

    Directory of Open Access Journals (Sweden)

    M. Ayadi

    2013-07-01

    Full Text Available A total of 22 dairy dromedary camels under intensive conditions in late lactation (275±24 days were used to study the relationship between external and internal udder morphology and machine milking performances. Measurements of udder and teat morphology were obtained immediately before milking and in duplicate. Individual milk yield, lag time and total milking time were recorded during milking, and milk samples were collected and analyzed for milk composition thereafter. Cisternal and alveolar milk volumes and composition were evaluated at 9 h milking interval. Results revealed that dairy camels had well developed udders and milk veins, with medium sized teats. On average, milk yield as well as milk fat and protein contents were 4.80±0.50 L d-1, 2.61±0.16% and 3.08±0.05%, respectively. The low fat values observed indicated incomplete milk letdown during machine milking. Lag time, and total milking time were 3.0±0.3, and 120.0±8.9s, on average, respectively. Positive correlations (p<0.05 were observed between milk yield and udder depth (r=0.37, distance between teats (r=0.57 and milk vein diameter (r=0.28, while a negative correlation was found with udder height (r=-0.25, p<0.05. Cisternal milk accounted for 11% of the total udder milk. Positive correlations were observed between total milk yield and volume of alveolar milk (r=0.98; p<0.001 as well as with volume of cisternal milk (r=0.63, p<0.05. Despite the low udder milk storage capacity observed in dairy camels, our study concluded that the evaluated dromedary sample had adequate udder morphology for machine milking. Finally, positive relationships were detected between milk yield and udder morphology traits of dairy camels.

  6. Loengud. Kontsert. Koorid. Teated

    Index Scriptorium Estoniae

    2006-01-01

    Loengust "Muusikaesseistika I" 19. sept. Lai t 34 aud 72. Kontsertidest: Tartu raekojas 22. sept. esineb hispaania ansambel Zarabanda, TÜ aulas 20. sept. esinevad "Meistrite akadeemia" sarjas Pille Lille Muusikute Toetusfondi laureaat Anna-Liisa Bezrodnõi viiulil ja Thea Nestor klaveril. TÜ Kammerkoor ja Tartu Akadeemiline Meeskoor võtavad vastu uusi liikmeid (info: www.ut.ee/TYKK ja www.tam.eu). Tartu Ülikooli rahvakunstiansambel ootab uusi tantsijaid (info: www.ut.ee)

  7. Natural Type II Collagen Hydrogel, Fibrin Sealant, and Adipose-Derived Stem Cells as a Promising Combination for Articular Cartilage Repair.

    Science.gov (United States)

    Lazarini, Mariana; Bordeaux-Rego, Pedro; Giardini-Rosa, Renata; Duarte, Adriana S S; Baratti, Mariana Ozello; Zorzi, Alessandro Rozim; de Miranda, João Batista; Lenz Cesar, Carlos; Luzo, Ângela; Olalla Saad, Sara Teresinha

    2017-10-01

    Objective Articular cartilage is an avascular tissue with limited ability of self-regeneration and the current clinical treatments have restricted capacity to restore damages induced by trauma or diseases. Therefore, new techniques are being tested for cartilage repair, using scaffolds and/or stem cells. Although type II collagen hydrogel, fibrin sealant, and adipose-derived stem cells (ASCs) represent suitable alternatives for cartilage formation, their combination has not yet been investigated in vivo for focal articular cartilage defects. We performed a simple experimental procedure using the combination of these 3 compounds on cartilage lesions of rabbit knees. Design The hydrogel was developed in house and was first tested in vitro for chondrogenic differentiation. Next, implants were performed in chondral defects with or without ASCs and the degree of regeneration was macroscopically and microscopically evaluated. Results Production of proteoglycans and the increased expression of collagen type II (COL2α1), aggrecan (ACAN), and sex-determining region Y-box 9 (SOX9) confirmed the chondrogenic character of ASCs in the hydrogel in vitro. Importantly, the addition of ASC induced a higher overall repair of the chondral lesions and a better cellular organization and collagen fiber alignment compared with the same treatment without ASCs. This regenerating tissue also presented the expression of cartilage glycosaminoglycan and type II collagen. Conclusions Our results indicate that the combination of the 3 compounds is effective for articular cartilage repair and may be of future clinical interest.

  8. Tubeless percutaneous nephrolithotomy with non-absorbable hemostatic sealant (Quikclot®) versus nephrostomy tube placement: a propensity score-matched analysis.

    Science.gov (United States)

    Koo, Kyo Chul; Park, Sang Un; Jang, Ho Sung; Hong, Chang-Hee

    2015-11-01

    The purpose of this study was to determine the efficacy and safety of tubeless percutaneous nephrolithotomy (PNL) using a non-absorbable hemostatic sealant (Quikclot(®)) as an adjunct compared to nephrostomy tube placement in patients exhibiting significant parenchymal bleeding following PNL. We identified 113 PNL cases performed between May 2011 and October 2014. For patients with insignificant parenchymal bleeding following stone removal, defined as a clear visualization of the surgical field at full irrigation of the nephroscope, tubeless PNL was performed. For patients with significant parenchymal bleeding, we introduced the tubeless Quikclot(®) technique as of September 2013 and have performed it ever since. Formerly, nephrostomy placement PNL was performed. In this study, 40 Quikclot(®) applied PNL cases were matched with an equal number of nephrostomy placement cases by propensity scoring based on body mass index, stone size, and Guy's stone score. The mean postoperative drop in hematocrit was comparative between the Quikclot(®) group and the nephrostomy group on both postoperative days 1 (p = 0.459) and 2 (p = 0.325). Quikclot(®) application was associated with lower VAS scores throughout the postoperative period, lower cumulative analgesic requirement (p = 0.025), and with shorter hospitalization (p = 0.002). Complication rates were comparable with no need for blood transfusions in any patients. Tubeless Quikclot(®) PNL was safe and provided effective hemostasis of significant parenchymal bleeding. By avoiding nephrostomy placement, we were able to reduce postoperative pain, analgesic requirements, and hospitalization. Application of Quikclot(®) may be considered prior to nephrostomy placement in patients with significant parenchymal bleeding.

  9. Testing of isolation barrier sealing surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Graves, C.E.

    1994-12-15

    Isolation barrier doors are to be installed in the 105KE and 105KW basins as part of the 1994 unreviewed safety question (USQ) resolution plan to isolate the fuel storage basin from the fuel discharge chute. Included in this installation is the placement of new sealing surfaces for the barriers by affixing stainless steel plates to existing carbon steel angle bars with a specially formulated epoxy adhesive/sealant material. The sealant is a two-part component consisting of an epoxy resin (the condensation product of bisphenol A and epichlorohydrin) and a curing agent (a proprietary cycloaliphatic polyamine). The sealant is solvent free (complying with air pollution regulations) and capable of withstanding the surrounding radiation fields over an estimated 15-year service life. The epoxy sealant experiences negligible water damage partly because of its hydrophobic (water-repelling) nature. With bond tensile strengths measured at greater than 862 kPa (125 lbf/in{sup 2}), the epoxy sealant is judged acceptable for its intended application. The four-hour pot life of the epoxy sealant provides sufficient time to apply the epoxy, examine the epoxy bead for continuity, and position the stainless steel sealing plates.

  10. Testing of isolation barrier sealing surfaces

    International Nuclear Information System (INIS)

    Graves, C.E.

    1994-01-01

    Isolation barrier doors are to be installed in the 105KE and 105KW basins as part of the 1994 unreviewed safety question (USQ) resolution plan to isolate the fuel storage basin from the fuel discharge chute. Included in this installation is the placement of new sealing surfaces for the barriers by affixing stainless steel plates to existing carbon steel angle bars with a specially formulated epoxy adhesive/sealant material. The sealant is a two-part component consisting of an epoxy resin (the condensation product of bisphenol A and epichlorohydrin) and a curing agent (a proprietary cycloaliphatic polyamine). The sealant is solvent free (complying with air pollution regulations) and capable of withstanding the surrounding radiation fields over an estimated 15-year service life. The epoxy sealant experiences negligible water damage partly because of its hydrophobic (water-repelling) nature. With bond tensile strengths measured at greater than 862 kPa (125 lbf/in 2 ), the epoxy sealant is judged acceptable for its intended application. The four-hour pot life of the epoxy sealant provides sufficient time to apply the epoxy, examine the epoxy bead for continuity, and position the stainless steel sealing plates

  11. SOLID RADIOACTIVE WASTE STORAGE TECHNOLOGIES: PERFORMANCE OF A POLYMER SEALANT COATING IN AN ARCTIC MARINE ENVIRONMENT

    International Nuclear Information System (INIS)

    COWGILL, M.G.; MOSKOWITZ, P.D.; CHERNAENKO, L.M.; NAZARIAN, A.; GRIFFITH, A.; DIASHEV, A.; ENGOY, T.

    2000-01-01

    This first project, under the auspices of the Arctic Military Environmental Cooperation (AMEC) forum, Project 1.4-1 Solid Radioactive Waste Storage Technologies, successfully demonstrated the feasibility of using a polymer-based coating to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment. A mobile, self-sufficient spraying device, was developed to specifications provided by the Russian Ministry of Defence Northern Navy and was deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings of Polibrid 705 were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading bay. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors and exposed to the full 12 month Arctic weather cycle. The field tests were accompanied by a series of laboratory qualification tests carried out at the research laboratory of ICC Nuclide in St. Petersburg. During the 12-month field tests, the sealant coating showed little sign of degradation except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. In the laboratory testing, Polibrid 705 met all the Russian qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities. The Russian technical experts from the Ministry of Defence quickly familiarized themselves with the equipment and were able to identify several areas of potential improvement as deployment of the equipment progressed. The prime among these was the desirability of extending the range of the equipment through enlarged gasoline tanks (to permit extended operational times) and longer

  12. Inhalation exposure during spray application and subsequent sanding of a wood sealant containing zinc oxide nanoparticles.

    Science.gov (United States)

    Cooper, Michael R; West, Gavin H; Burrelli, Leonard G; Dresser, Daniel; Griffin, Kelsey N; Segrave, Alan M; Perrenoud, Jon; Lippy, Bruce E

    2017-07-01

    Nano-enabled construction products have entered into commerce. There are concerns about the safety of manufactured nanomaterials, and exposure assessments are needed for a more complete understanding of risk. This study assessed potential inhalation exposure to ZnO nanoparticles during spray application and power sanding of a commercially available wood sealant and evaluated the effectiveness of local exhaust ventilation in reducing exposure. A tradesperson performed the spraying and sanding inside an environmentally-controlled chamber. Dust control methods during sanding were compared. Filter-based sampling, electron microscopy, and real-time particle counters provided measures of exposure. Airborne nanoparticles above background levels were detected by particle counters for all exposure scenarios. Nanoparticle number concentrations and particle size distributions were similar for sanding of treated versus untreated wood. Very few unbound nanoparticles were detected in aerosol samples via electron microscopy, rather nano-sized ZnO was contained within, or on the surface of larger airborne particles. Whether the presence of nanoscale ZnO in these aerosols affects toxicity merits further investigation. Mass-based exposure measurements were below the NIOSH Recommended Exposure Limit for Zn, although there are no established exposure limits for nanoscale ZnO. Local exhaust ventilation was effective, reducing airborne nanoparticle number concentrations by up to 92% and reducing personal exposure to total dust by at least 80% in terms of mass. Given the discrepancies between the particle count data and electron microscopy observations, the chemical identity of the airborne nanoparticles detected by the particle counters remains uncertain. Prior studies attributed the main source of nanoparticle emissions during sanding to copper nanoparticles generated from electric sander motors. Potentially contrary results are presented suggesting the sander motor may not have been

  13. Effect of platelet rich plasma and fibrin sealant on facial nerve regeneration in a rat model.

    Science.gov (United States)

    Farrag, Tarik Y; Lehar, Mohamed; Verhaegen, Pauline; Carson, Kathryn A; Byrne, Patrick J

    2007-01-01

    To investigate the effects of platelet rich plasma (PRP) and fibrin sealant (FS) on facial nerve regeneration. Prospective, randomized, and controlled animal study. Experiments involved the transection and repair of facial nerve of 49 male adult rats. Seven groups were created dependant on the method of repair: suture; PRP (with/without suture); platelet poor plasma (PPP) (with/without suture); and FS (with/without suture) groups. Each method of repair was applied immediately after the nerve transection. The outcomes measured were: 1) observation of gross recovery of vibrissae movements within 8-week period after nerve transection and repair using a 5-point scale and comparing the left (test) side with the right (control) side; 2) comparisons of facial nerve motor action potentials (MAP) recorded before and 8 weeks after nerve transection and repair, including both the transected and control (untreated) nerves; 3) histologic evaluation of axons counts and the area of the axons. Vibrissae movement observation: the inclusion of suturing resulted in overall improved outcomes. This was found for comparisons of the suture group with PRP group; PRP with/without suture groups; and PPP with/without suture groups (P .05). The movement recovery of the suture group was significantly better than the FS group (P = .014). The recovery of function of the PRP groups was better than that of the FS groups, although this did not reach statistical significance (P = .09). Electrophysiologic testing: there was a significantly better performance of the suture group when compared with the PRP and PPP without suture groups in nerve conduction velocity (P facial nerve axotomy models occurred when the nerve ends were sutured together. At the same time, the data demonstrated a measurable neurotrophic effect when PRP was present, with the most favorable results seen with PRP added to suture. There was an improved functional outcome with the use of PRP in comparison with FS or no bioactive

  14. SOLID RADIOACTIVE WASTE STORAGE TECHNOLOGIES: PERFORMANCE OF A POLYMER SEALANT COATING IN AN ARCTIC MARINE ENVIRONMENT

    Energy Technology Data Exchange (ETDEWEB)

    COWGILL,M.G.; MOSKOWITZ,P.D.; CHERNAENKO,L.M.; NAZARIAN,A.; GRIFFITH,A.; DIASHEV,A.; ENGOY,T.

    2000-06-14

    This first project, under the auspices of the Arctic Military Environmental Cooperation (AMEC) forum, Project 1.4-1 Solid Radioactive Waste Storage Technologies, successfully demonstrated the feasibility of using a polymer-based coating to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment. A mobile, self-sufficient spraying device, was developed to specifications provided by the Russian Ministry of Defence Northern Navy and was deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings of Polibrid 705 were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading bay. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors and exposed to the full 12 month Arctic weather cycle. The field tests were accompanied by a series of laboratory qualification tests carried out at the research laboratory of ICC Nuclide in St. Petersburg. During the 12-month field tests, the sealant coating showed little sign of degradation except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. In the laboratory testing, Polibrid 705 met all the Russian qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities. The Russian technical experts from the Ministry of Defence quickly familiarized themselves with the equipment and were able to identify several areas of potential improvement as deployment of the equipment progressed. The prime among these was the desirability of extending the range of the equipment through enlarged gasoline tanks (to permit extended operational times) and longer

  15. Genetic parameters and genetic trends in the Chinese × European Tiameslan composite pig line. I. Genetic parameters

    Directory of Open Access Journals (Sweden)

    Legault Christian

    2000-01-01

    Full Text Available Abstract Genetic parameters of body weight at 4 (W4 w, 8 (W8 w and 22 (W22 w weeks of age, days from 20 to 100 kg (DT, average backfat thickness at 100 kg (ABT, teat number (TEAT, number of good teats (GTEAT, total number of piglets born (TNB, born alive (NBA and weaned (NW per litter, and birth to weaning survival rate (SURV were estimated in the Chinese × European Tiameslan composite line using restricted maximum likelihood methodology applied to a multiple trait animal model. Performance data from a total of 4 881 males and 4 799 females from 1 341 litters were analysed. Different models were fitted to the data in order to estimate the importance of maternal effects on production traits, as well as genetic correlations between male and female performance. The results showed the existence of significant maternal effects on W4w, W8w and ABT and of variance heterogeneity between sexes for W22w, DT, ABT and GTEAT. Genetic correlations between sexes were 0.79, 0.71 and 0.82, respectively, for W22w, DT and ABT and above 0.90 for the other traits. Heritability estimates were larger than (ABT and TEAT or similar to (other traits average literature values. Some genetic antagonism was evidenced between production traits, particularly W4w, W8w and ABT, and reproductive traits.

  16. The use of FloSeal haemostatic sealant in the management of epistaxis: a prospective clinical study and literature review.

    Science.gov (United States)

    Wakelam, O C; Dimitriadis, P A; Stephens, J

    2017-01-01

    INTRODUCTION It is standard practice in the UK that if conservative measures or chemical cautery fail to control epistaxis, patients receive nasal packing which is often uncomfortable, requires admission and has well documented associated morbidity. Our study aims to evaluate the use of FloSeal haemostatic sealant in managing patients with epistaxis. MATERIALS AND METHODS Patients were identified from those referred with active epistaxis. A successful outcome was defined as complete haemostasis with FloSeal alone, with no further significant bleeding requiring admission or further interventions in the subsequent 7 days. Patients reported satisfaction using a ten-point visual analogue scale. Ear, nose and throat doctors recorded patient demographics, time to prepare FloSeal, length of stay, need for further treatment and adverse events on an electronic database. RESULTS 30 patients were enrolled in the study. The mean time to prepare FloSeal was 5 minutes. The success rate of FloSeal was 90%. The mean length of stay was 2.75 hours. The mean patient satisfaction with FloSeal was 8.4/10. No adverse events occurred. DISCUSSION FloSeal was found to be effective in controlling anterior epistaxis. There was a single case of posterior epistaxis which required operative management. The literature largely supports FloSeal in anterior epistaxis, but indicates sphenopalatine artery ligation as the definitive management of posterior epistaxis. CONCLUSIONS Our data support the use of FloSeal in patients with anterior epistaxis not controlled with conservative measures or chemical cautery. It was found to be easy to use, is well tolerated by patients and is efficient in financial terms.

  17. Avaliação clínica de um cimento de ionômero de vidro utilizado como selante oclusal: a clinical evaluation Use of a glass ionomer cement as an occlusal sealant

    Directory of Open Access Journals (Sweden)

    Pedro Cheque BERNARDO

    2000-03-01

    Full Text Available Sabendo-se do papel do flúor na Odontologia Preventiva, cada vez mais procuram-se materiais restauradores com propriedades de liberação deste íon. Dentre os selantes oclusais, grande expectativa existe em relação aos cimentos de ionômero de vidro, particularmente os fotopolimerizáveis, por possuírem melhores propriedades. O objetivo deste trabalho foi testar um destes cimentos, Vitremer (3M, aplicado em: combinação ou não com um adesivo. A avaliação foi realizada em 159 dentes, 6 e 12 meses após a aplicação do selante, observando-se sua retenção e a presença ou ausência de lesão de cárie. Concluiu-se que a técnica modificada, com adesivo, propiciou significativamente melhor retenção após 6 e 12 meses que a técnica convencional, não havendo diferença entre molares e pré-molares. Apenas um dente do grupo sem adesivo desenvolveu lesão de cárie após a perda do material.Since fluoride’s properties are widely known in the field of Preventive Dentistry, fluoride-releasing materials have been extensively investigated. Among the occlusal sealants, there is great expectation regarding the results that can be achieved with light-curing glass-ionomer cements due to their excellent properties. The aim of this study was to assess the use of one of these cements, Vitremer (3M as an occlusal sealant. The material was applied using two different techniques; either associated or not with an adhesive system. After 6 and 12 months of observation, an evaluation was performed in 159 teeth to verify its retention as well as the presence of caries lesions. The technique that included the adhesive system showed better retention than the conventional one. Total retention was 84.9% for the experimental technique and 37.2% for the conventional technique after 12 months. There was no difference between bicuspids and molars regarding retention. Caries lesion was observed in a single tooth, for which a total loss of material was observed

  18. Management practices from questionnaire surveys in herds with very low somatic cell score through a national mastitis program in France.

    Science.gov (United States)

    Barnouin, J; Chassagne, M; Bazin, S; Boichard, D

    2004-11-01

    French dairy herds (n = 534) were enrolled in the National 'Zero Mastitis Objective' Program to highlight management practices characterizing very low somatic cell score (SCS) herds. The herds studied were stratified into 2 groups. The first group (LOW) included herds within the first 5 percentiles and the second group (MED) herds within the 50 to 55 percentiles of herds on the basis of mean SCS for the 36 mo preceding the program. Potential explanatory variables, collected through questionnaire surveys, were analyzed using multistep logistic regression models. Twenty-six variables were significant factors in the final models, in which 18 were considered as primary factors for very low SCS. The probability for a herd belonging to the LOW group was associated with: (1) regular use of teat spraying; (2) herdsman precise in his techniques; (3) less than 1 person-year used at activities other than dairy herd; (4) teat dipping after mammary infusion at dry off; (5) heifers kept in a calving pen around parturition; (6) cows locked in feed-line lockups after milking; (7) dry cows with prepartum Ca restriction; (8) heifers on a nondamp pasture; (9) cows culled when at least one damaged teat; (10) heifers at pasture not drinking water from a river; and (11) disinfecting teat ends with alcohol before intramammary infusion at dry off. The probability for a herd belonging to the MED group was associated with: (1) milking cows housed in a straw yard; (2) checking heifers for mastitis only beginning at 2-wk prepartum; (3) no mastitis treatment when at least one clot was observed in milk at successive milkings; (4) distance of herdsman's house to cowshed >300 m; (5) only dirty teats washed before milking; (6) free access of cows from pasture to cowshed during bad weather; and (7) more than 18% of spring calvings. The variables associated with very low SCS should be applied as part of a thorough mastitis-control program adapted to each herd.

  19. The use of a 'bleach-etch-seal' deproteinization technique on MIH affected enamel.

    Science.gov (United States)

    Gandhi, Shan; Crawford, Peter; Shellis, Peter

    2012-11-01

    To ascertain whether deproteinization pretreatment of molar-incisor hypomineralization (MIH) enamel affects resin sealant infiltration. Thirty one extracted MIH teeth were divided into three sections and randomly allocated into the Control (etch and FS), Treatment 1 (5% NaOCl, etched and fissure sealed), and Treatment 2 (5% NaOCl and fissure sealed with no etch) groups. Two hundred seventy nine sealant tag/enamel grade observations were recorded by scanning electron microscopy. Control and Treatment 1 were similar in their outcomes, and Treatment 2 was markedly different. There was no statistical evidence to suggest that there was any difference between Treatment 1 and the Control Treatment (95% CI, 0.52, 1.51; P = 0.6). There was a marked difference between Treatment 2 and the Control Treatment (95% CI, 0.07, 0.25; P MIH enamel, regardless of which of the three treatments was used. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  20. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    Science.gov (United States)

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  1. Avaliação da microinfiltração marginal e profundidade de penetração dos cimentos de ionômero de vidro utilizados como selantes oclusais Evaluation of marginal microleakage and depth of penetration of glass ionomer cements used as occlusal sealants

    Directory of Open Access Journals (Sweden)

    Marina de Lourdes Calvo Fracasso

    2005-09-01

    Full Text Available OBJETIVE: the aim of this study was to conduct an in vitro comparison of marginal microleakage (MM and the depth of penetration (DP of glass ionomer cements (GIC and a resin sealant (RS into occlusal pit and fissures. METHODS: for that purpose, 60 intact third molars were equally distributed to 5 groups: G1 - 37% phosphoric acid / Delton; G2 - 40% polyacrylic acid / Ketac-Molar / nail varnish; G3 - Fuji Plus conditioner / Fuji Plus/ nail varnish; G4 -37% phosphoric acid / Vitremer / Finishing gloss; G5 -37% phosphoric acid / Vitremer prepared with a 1:4 ratio of powder / Finishing gloss. The teeth were submitted to a thermal treatment corresponding to 300 cycles (15 sec, 5/55(0C, followed by complete coating with nail varnish, except for 1mm beyond the contour of the sealant. Afterwards, the teeth were immersed in 0.5% basic fuchsine for 24 hours. Thereafter, the teeth were sectioned in buccolingual direction and microscopically analyzed (150x magnification by means of predetermined scores. The results were subject to the Kruskal-Wallis test. RESULTS: there was no statistical difference between the materials tested in relation to the DP, being that all groups displayed nearly complete filling of the fissures. No sealant material was able to prevent dye penetration; however, the GICs provided better results of MM, with significant difference when compared to the RS. CONCLUSION: all materials investigated presented a satisfactory degree of penetration into the fissures; however, the glass ionomer cements displayed better performance in the marginal microleakage test compared to the resin sealant.OBJETIVO: o objetivo deste estudo foi comparar in vitro a microinfiltração marginal (MM e o grau de profundidade de penetração (DP de cimentos de ionômero de vidro (CIV e um selante resinoso (SR em fossas e fissuras oclusais. MATERIAIS E MÉTODOS: para tanto, 60 terceiros molares hígidos foram igualmente distribuídos em 5 grupos: G1- ácido fosf

  2. Evaluation of selective dry cow treatment following on-farm culture: risk of postcalving intramammary infection and clinical mastitis in the subsequent lactation.

    Science.gov (United States)

    Cameron, M; McKenna, S L; MacDonald, K A; Dohoo, I R; Roy, J P; Keefe, G P

    2014-01-01

    The objective of the study was to evaluate the utility of a Petrifilm-based on-farm culture system when used to make selective antimicrobial treatment decisions on low somatic cell count cows (cows from 16 commercial dairy herds with a low bulk tank somatic cell count (cow therapy (DCT) or Petrifilm-based selective DCT. Cows belonging to the blanket DCT group were infused with a commercial dry cow antimicrobial product and an internal teat sealant (ITS) at drying off. Using composite milk samples collected on the day before drying off, cows in the selective DCT group were treated at drying off based on the results obtained by the Petrifilm on-farm culture system with DCT + ITS (Petrifilm culture positive), or ITS alone (Petrifilm culture negative). Quarters of all cows were sampled for standard laboratory bacteriology on the day before drying off, at 3 to 4d in milk (DIM), at 5 to 18 DIM, and from the first case of clinical mastitis occurring within 120 DIM. Multilevel logistic regression was used to assess the effect of study group (blanket or selective DCT) and resulting dry cow treatment (DCT + ITS, or ITS alone) on the risk of intramammary infection (IMI) at calving and the risk of a first case of clinical mastitis between calving and 120 DIM. According to univariable analysis, no difference was observed between study groups with respect to quarter-level cure risk and new IMI risk over the dry period. Likewise, the risk of IMI at calving and the risk of clinical mastitis in the first 120 DIM was not different between quarters belonging to cows in the blanket DCT group and quarters belonging to cows in the selective DCT group. The results of this study indicate that selective DCT based on results obtained by the Petrifilm on-farm culture system achieved the same level of success with respect to treatment and prevention of IMI over the dry period as blanket DCT and did not affect the risk of clinical mastitis in the first 120 d of the subsequent lactation

  3. Electrophoretic deposition of Mn1.5Co1.5O4 on metallic interconnect and interaction with glass-ceramic sealant for solid oxide fuel cells application

    DEFF Research Database (Denmark)

    Smeacetto, Federico; De Miranda, Auristela; Cabanas Polo, Sandra

    2015-01-01

    Cr-containing stainless steels are widely used as metallic interconnects for SOFCs. Volatile Cr-containing species, which originate from the oxide formed on steel, can poison the cathode material and subsequently cause degradation in the SOFC stack. Mn1.5Co1.5O4 spinel is one of the most promisin...... between Mn1.5Co1.5O4 coated Crofer22APU and a new glass-ceramic sealant, after 500 h of thermal tests in air, thus suggesting that the spinel protection layer can effectively act as a barrier to outward diffusion of Cr. [All rights reserved Elsevier].......Cr-containing stainless steels are widely used as metallic interconnects for SOFCs. Volatile Cr-containing species, which originate from the oxide formed on steel, can poison the cathode material and subsequently cause degradation in the SOFC stack. Mn1.5Co1.5O4 spinel is one of the most promising...... coating materials due to its high electrical conductivity, good CTE match with the stainless steel substrate and an excellent chromium retention capability. In this work Mn1.5Co1.5O4 spinel coatings are deposited on Crofer22APU substrates by cathodic electrophoretic deposition (EPD) followed by sintering...

  4. Mammary gland pathologies in the parturient buffalo

    Directory of Open Access Journals (Sweden)

    G N Purohit

    2014-12-01

    Full Text Available Parturition related mammary gland pathologies in the buffalo appear to be low on accord of anatomic (longer teat length, thicker streak canal and physiologic (lower cisternal storage of secreted milk, lower milk production differences with cattle. Hemolactia, udder edema and hypogalactia usually occur in the buffalo due to physiologic changes around parturition however mastitis involves pathologic changes in the udder and teats; the incidence of mastitis is however lower compared to cattle. The incidence and therapy of hemolactia, udder edema and hypogalactia are mentioned and the risk factors, incidence, diagnosis, therapy and prevention for mastitis in buffalo are also described.

  5. Pathogen group specific risk factors for clinical mastitis, intramammary infection and blind quarters at the herd, cow and quarter level in smallholder dairy farms in Jimma, Ethiopia.

    Science.gov (United States)

    Tolosa, T; Verbeke, J; Ayana, Z; Piepers, S; Supré, K; De Vliegher, S

    2015-07-01

    A cross-sectional study on clinical mastitis, intramammary infection (IMI) and blind quarters was conducted on 50 smallholder dairy farms in Jimma, Ethiopia. A questionnaire was performed, and quarters of 211 cows were sampled and bacteriologically cultured. Risk factors at the herd, cow, and quarter level for clinical mastitis and (pathogen-specific) intramammary infection were studied using multilevel modeling. As well, factors associated with quarters being blind were studied. Eleven percent of the cows and 4% of the quarters had clinical mastitis whereas 85% of the cows and 51% of the quarters were infected. Eighteen percent of the cows had one or more blind quarter(s), whereas 6% of the quarters was blind. Non-aureus staphylococci were the most frequently isolated pathogens in both clinical mastitis cases and IMI. The odds of clinical mastitis was lower in herds where heifers were purchased in the last year [odds ratio (OR) with 95% confidence interval: 0.11 (0.01-0.90)], old cows (>4 years) [OR: 0.45 (0.18-1.14)], and quarters not showing teat injury [OR: 0.23 (0.07-0.77)]. The odds of IMI caused by any pathogen was higher in herds not practicing teat drying before milking (opposed to drying teats with 1 towel per cow) [OR: 1.68 (1.05-2.69)], cows in later lactation (>180 DIM opposed to ≤90 DIM) [OR: 1.81 (1.14-2.88)], cows with a high (>3) body condition score (BCS) [OR: 1.57 (1.06-2.31)], right quarters (opposed to a left quarter position) [OR: 1.47 (1.10-1.98)], and quarters showing teat injury [OR: 2.30 (0.97-5.43)]. Quarters of cows in herds practicing bucket-fed calf feeding (opposed to suckling) had higher odds of IMI caused by Staphylococcus aureus [OR: 6.05 (1.31-27.90)]. Except for BCS, IMI caused by non-aureus staphylococci was associated with the same risk factors as IMI caused by any pathogen. No access to feed and water immediately after milking [OR: 2.41 (1.26-4.60)], higher parity [OR: 3.60 (1.20-10.82)] and tick infestation [OR: 2.42 (1

  6. Sealing of leaks in the bioshield cooling system of three research reactors

    International Nuclear Information System (INIS)

    May, R.; Taylor, M.F.

    1995-01-01

    Water leaks have occurred in the bioshield cooling system of three research reactors. These leaks have been plugged with a sealant based on a blend of a water-based resin and a bentonite-type clay originally developed for sealing similar leaks on power reactors. The mechanism of sealing and development testing of the sealant are described. Application of the sealant to the three reactors sealed the leaks. However, unlike experience with leaks in steel and aluminium systems, some leaks reappeared after several months service - albeit at a leak rate only a very small fraction of the original leak rate. The recurrent defects were readily retreated with sealant and hence, in these instances, the treatment is an effective maintenance procedure for any ageing reactor rather than a permanent cure. (orig.)

  7. Association of udder traits with single nucleotide polymorphisms in crossbred Bos indicus-Bos taurus cows.

    Science.gov (United States)

    Tolleson, M W; Gill, C A; Herring, A D; Riggs, P K; Sawyer, J E; Sanders, J O; Riley, D G

    2017-06-01

    The size, support, and health of udders limit the productive life of beef cows, especially those with background, because, in general, such cows have a reputation for problems with udders. Genomic association studies of bovine udder traits have been conducted in dairy cattle and recently in Continental European beef breeds but not in cows with background. The objective of this study was to determine associations of SNP and udder support scores, teat length, and teat diameter in half (Nellore), half (Angus) cows. Udders of cows ( = 295) born from 2003 to 2007 were evaluated for udder support and teat length and diameter ( = 1,746 records) from 2005 through 2014. These included a subjective score representing udder support (values of 1 indicated poorly supported, pendulous udders and values of 9 indicated very well-supported udders) and lengths and diameters of individual teats in the 4 udder quarters as well as the average. Cows were in full-sibling or half-sibling families. Residuals for each trait were produced from repeated records models with cow age category nested within birth year of cows. Those residuals were averaged to become the dependent variables for genomewide association analyses. Regression analyses of those dependent variables included genotypic values as explanatory variables for 34,980 SNP from a commercially available array and included the genomic relationship matrix. Fifteen SNP loci on BTA 5 were associated (false discovery rate controlled at 0.05) with udder support score. One of those was also detected as associated with average teat diameter. Three of those 15 SNP were located within genes, including one each in (), (), and (). These are notable for their functional role in some aspect of mammary gland formation or health. Other candidate genes for these traits in the vicinity of the SNP loci include () and (). Because these were detected in Nellore-Angus crossbred cows, which typically have very well-formed udders with excellent support

  8. Physical and thermal behaviour of Sr-La-Al-B-Si based SOFC glass sealants as function of SrO content and B2O3/SiO2 ratio in the matrix

    Science.gov (United States)

    Ojha, Prasanta Kumar; Rath, S. K.; Chongdar, T. K.; Gokhale, N. M.; Kulkarni, A. R.

    2011-05-01

    A series of SOFC glass sealants with composition SrO (x), La2O3 (15), Al2O3 (15), B2O3 (40 - x), and SiO2 (30) [x = 10, 15, 20, 25 and 30] (wt.%) [SLABS] are investigated for their structure property correlations at different compositions. Quantitative Fourier transform infrared spectroscopy shows structural rigidity with increasing SrO content, as demonstrate by an increase in the Si-O-Si/O-Si-O bending and B-O-B stretching frequencies. The role of SrO as a modifier dominates the control of the structure and behaviour of glasses compared with the effect of network formers, i.e., the B2O3/SiO2 ratio. Consequent to the structural changes, increasing substitution of B2O3 by SrO the glasses causes increases in the density, glass transition temperature and dilatometric softening point. On the other hand, the crystallization temperatures show a decreasing trend and the coefficient of thermal expansion increases with increase in substitution.

  9. 78 FR 27953 - Notification of Proposed Production Activity, CNH America, LLC, Subzone 59B, (Agricultural...

    Science.gov (United States)

    2013-05-13

    ... housings; vertical auger tubes; chopper drive gearbox accessories; cotton picker frames and cabs; and, non... components and materials sourced from abroad include: sealant; sealant paste; oil drain assemblies; rubber... axles; radiators; temperature sensors; pressure gauges; and, seats (duty rates range from free to 5...

  10. Quantification and Management of Manifest Occlusal Caries Lesions in Adults: A Methodological and a Clinical Study

    DEFF Research Database (Denmark)

    Bakhshandeh, Azam

    2010-01-01

    teeth with primary occlusal lesions. Randomization was performed in cases of more than one lesion in the same patient, so that the final material consisted of 60 resin sealed and 12 restored lesions. After 2-3 years, there was a drop-out of 15%; 2 patients did not show up for the control and 9...... extension of the lesions from baseline and the last control radiograph, there was scored caries progression beneath 5 (10%) of 49 sealants, caries regression beneath 1 (2%) sealant and unchanged lesion depth beneath 43 (88%) sealants and all restorations (p = 0.64). The methodological study included 110...

  11. Exploring the determinants of secular decreases in dental caries among Korean children.

    Science.gov (United States)

    Lee, Hye-Ju; Han, Dong-Hun

    2015-08-01

    The aim of this study was to determine the contributions of sealant and water fluoridation to the time trends in dental caries from 2003 to 2010. Data were from three waves of the Korean National Oral Health Surveys between 2003 and 2010, including a total of 23 059 children (11 889 boys and 11 170 girls) aged 8, 10, and 12 years. The impacts of sealant and water fluoridation on dental caries were obtained by logistic regression for each age group of children. The contributions of sealant and water fluoridation to the time trends in the prevalence of dental caries were examined by a series of logistic regression models, and changes in the adjusted odds ratios for each survey year were also calculated. Over the past 7 years, the prevalence of dental caries decreased dramatically. Although sealant had a significant impact on dental caries in each survey year, remarkable decreases in dental caries from 2003 to 2010 were not explained by the secular changes in the dental sealant or water fluoridation factor. We observed important population declines in dental caries in Korea in children aged 8-12 years; however, the likely causes for these secular trends remain to be determined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Topical fibrin sealant versus intravenous tranexamic acid for reducing blood loss following total knee arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2016-08-01

    Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. 78 FR 37156 - Airworthiness Directives; Eurocopter France Helicopters

    Science.gov (United States)

    2013-06-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that... prevent failure of the windows to jettison, so helicopter occupants can exit the aircraft during an... comments to the U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor...

  14. Kebutuhan Fisur Silen Gigi Posterior pada Murid-Murid Sekolah Dasar di Kota Madya Medan

    Directory of Open Access Journals (Sweden)

    Lina Natamiharja

    2015-10-01

    Full Text Available The application of pit and fissure sealants is widely accepted practice in carious prevention, these materials were developed in an effort to prevent plaque, bacteria and carbohydrates penetrating pits and fissures of the teeth. Fissure sealants are effective in preventing occlusal carious in 33 out of every 100 teeth. The purpose of this study was to determine the needs of fissure sealant among the children age 6-13 years old. This study was carried out in two elementary schools. Samples was taken by sistematic random sampling based on age and sex. The totals of samples was 430 children. The needs of fissure sealant in the molars were quite high (36,75%, the highest percentage was in the lower first molar (49,64%, followed by the lower second molar (42,92%. In the premolars the needs was low (8,02%, the greatest needs was in the lower second premolar (15,79% followed by upper first premolar (7,50%.

  15. Effect of different heat treatments and disinfectants on the survival of Prototheca zopfii.

    Science.gov (United States)

    Lassa, Henryka; Jagielski, Tomasz; Malinowski, Edward

    2011-03-01

    Bovine mastitis caused by the yeast-like alga Prototheca zopfii represents a serious veterinary problem and may result in heavy economic losses to particular dairy farms. The purpose of this study was to evaluate the survival of 50 isolates of P. zopfii in milk subjected to different heat treatments and the survival of further 106 P. zopfii isolates after exposure to three classes of teat disinfectants: iodine (Dipal), quaternary ammonium compounds (Teat), and dodecylbenzenesulphonic acid (Blu-gard). Of the 50 isolates tested for thermal tolerance, 29 (58%) survived heat treatment at 62 °C for 30 s and 13 (26% of all isolates) of those survived after heat treatment at 72 °C for 15 s. None of the 106 isolates were able to withstand the in-use concentrations of the three disinfectants tested. The highest disinfectant concentrations that permitted survival of at least one isolate were dilutions: 1:1,000 for Dipal (survival rate of 52.8-57.5%), 1:100 for Teat (88.7-90.6%), and 1:10 for Blu-gard (100%). No differences in the survival rates of P. zopfii were observed with respect to the duration of exposure to disinfectant. The results of this study support the previous findings that P. zopfii may resist high-temperature treatments, including that applied in the high-temperature, short-time (HTST) pasteurization process. The obtained data also demonstrate the efficacy of the three classes of teat disinfectants against P. zopfii, with the efficacy of iodine being most pronounced. The study emphasizes the necessity of using higher temperatures in the pasteurization of raw milk to kill the Prototheca algae, as well as the particular suitability of the iodine for the control procedures of protothecal mastitis.

  16. Prevalence, risk factors, and major bacterial causes of camel mastitis in Borana Zone, Oromia Regional State, Ethiopia.

    Science.gov (United States)

    Regassa, Alemayehu; Golicha, Gelma; Tesfaye, Dawit; Abunna, Fufa; Megersa, Bekele

    2013-10-01

    A cross-sectional study was carried out from November 2010 up to April 2011 to estimate mastitis prevalence and associated risk factors and to assess its bacterial causes in traditionally managed camels in Borana Zone, Southern Ethiopia. Thus, 348 lactating camels were examined clinically, and subclinical cases were checked with California mastitis test (CMT). The overall prevalence of mastitis was 44.8 % (156/348), comprising clinical (19, 5.4 %) and subclinical (137, 39.4 %) cases. The quarter level prevalence of mastitis was 24.0 % (334/1,392). Of the total 1,392 examined teats, 30 were blind, and hence, from the 1,362 non-blind CMT-examined teats, 22.3 % (304/1,362) were CMT positive. Of the 304 CMT-positive samples, 264 were culture positive (197 Gram-positive, 41 Gram-negative, and 26 mixed isolates), and 40 were culture negative. The prevalence of Staphylococcus aureus was found to be the highest at both the animal (12.8 %, 39/304) and quarter level (2.9 %, 39/1,362). Regression analysis revealed higher likelihood of mastitis occurrence among camels from Dharito (OR = 3.4, 95 % confidence interval (CI) = 1.8, 6.4), Gagna (OR = 3.4, 95 % CI = 1.8, 6.5), and Haro Bake (OR = 2.6, 95 % CI = 1.3, 5.1) than camels from Surupha. Likewise, there was higher chance of mastitis occurrence among camels at the early lactation stage (OR = 2.3, 95 % CI = 1.1, 4.6) and camels with udder/teat lesions (OR = 13.7, 95 % CI = 1.7, 109.4) than among camels at late lactation stage and camels with healthy udder/teats, respectively. In conclusion, this study reveals the current status of camel mastitis in Southern Ethiopia.

  17. Pangad kardavad Jukosele laenatud rahast ilma jääda / Raivo Sormunen

    Index Scriptorium Estoniae

    Sormunen, Raivo, 1976-

    2004-01-01

    Venemaa suurimale naftaeksportijale Jukos miljard dollarit laenanud pankade konsortsium, eesotsas pankadega Citigroup ja Societe Generale, saatis ettevõttele teate, väljendades muret laenuraha tagasisaamise suhtes

  18. Sealing versus partial caries removal in primary molars: a randomized clinical trial

    NARCIS (Netherlands)

    Hesse, D.; Bonifácio, C.C.; Mendes, F.M.; Braga, M.M.; Imparato, J.C.P.; Raggio, D.P.

    2014-01-01

    Background The resin-based pit and fissure sealant is considered a successful tool in caries prevention, however there is a growing evidence of its use in controlling already established caries in posterior teeth. The aim of this clinical trial is to verify the efficacy of pit and fissure sealants

  19. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].

    Science.gov (United States)

    Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao

    2016-06-01

    To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.

  20. Acute and latent infection by bovine herpesvirus type 2 in a guinea pig model.

    Science.gov (United States)

    Torres, Fabrício Dias; Cargnelutti, Juliana Felipetto; Masuda, Eduardo Kenji; Weiblen, Rudi; Flores, Eduardo Furtado

    2010-02-01

    Bovine herpetic mammillits is a self-limiting cutaneous disease of the udder and teats of cows associated with bovine herpesvirus 2 (BoHV-2) whose pathogenesis is poorly understood. This article describes the use of guinea pigs (Cavia porcellus) to study the pathogenesis of BoHV-2 infection. Twelve weanling female guinea pigs inoculated subcutaneously with BoHV-2 in the genitalia and teats developed local hyperemia, edema, vesicles, ulcers and scabs. Infectious virus was recovered between days 3 and 7 post-infection (pi) from the genital area (9/12) and teats (1/12); and all inoculated animals seroconverted (virus-neutralizing titers of 16-128). Histological examination of lesions revealed lymphoplasmacytic perivascular infiltrates and intranuclear inclusion bodies in keratinocytes. PCR examination of tissues collected at day 35 pi detected latent viral DNA predominantly in lumbosacral spinal segments. In another experiment, eight females inoculated with BoHV-2 in the genitalia and treated with dexamethasone (Dx) at day 35 pi developed mild to moderate local signs, yet no virus could be recovered from lesions. PCR examination of spinal segments from these animals confirmed the presence of latent viral DNA. These results demonstrate that guinea pigs are susceptible to BoHV-2 infection and therefore may be used to study selected aspects of BoHV-2 biology.

  1. Etiology, antimicrobial susceptibility profile of Staphylococcus spp. and risk factors associated with bovine mastitis in the states of Bahia and Pernambuco

    Directory of Open Access Journals (Sweden)

    Carina C. Krewer

    2013-05-01

    Full Text Available The purpose of this paper was to study the etiology of mastitis, determine the antimicrobial susceptibility profile of Staphylococcus spp. and to identify the risk factors associated with infection in dairy cows in the states of Bahia and Pernambuco, Brazil. From the 2,064 milk samples analyzed, 2.6% were associated with cases of clinical mastitis and 28.2% with subclinical mastitis. In the microbiological culture, Staphylococcus spp. (49.1% and Corynebacterium spp. (35.3% were the main agents found, followed by Prototheca spp. (4.6% and Gram negative bacilli (3.6%. In the antimicrobial susceptibility testing, all 218 Staphylococcus spp. were susceptible to rifampicin and the least effective drug was amoxicillin (32.6%. Multidrug resistance to three or more drugs was observed in 65.6% of Staphylococcus spp. The risk factors identified for mastitis were the extensive production system, not providing feed supplements, teat drying process, not disinfecting the teats before and after milking, and inadequate hygiene habits of the milking workers. The presence of multiresistant isolates in bovine milk demonstrates the importance of the choice and appropriate use of antimicrobial agents. Prophylactic and control measures, including teat antisepsis and best practices for achieving hygienic milking should be established in order to prevent new cases of the disease in herds.

  2. 78 FR 76984 - Airworthiness Directives; Eurocopter France Helicopters

    Science.gov (United States)

    2013-12-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that... prevent failure of the windows to jettison, so helicopter occupants can exit the aircraft during an... Office, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590...

  3. Requirements for Weatherproofing Thin Shell Concrete Roofs. Proceedings of the Conference of Building Research Institute, Division of Engineering and Industrial Research (Spring 1961).

    Science.gov (United States)

    National Academy of Sciences - National Research Council, Washington, DC.

    Topics discussed include--(1) requirements for weatherproofing and sealant materials for thin shell concrete roof, (2) effect of physical factors on weatherproofing of thin shell concrete roofs, (3) problems and limitations imposed by thin shell concrete roofs and their effect on weatherproofing and sealant materials, and (4) properties and uses…

  4. Naiste nappus kasvatab India ja Hiina ühiskondades vägivaldset käitumist / Arko Olesk

    Index Scriptorium Estoniae

    Olesk, Arko, 1981-

    2006-01-01

    Poisslapsi eelistav traditsioon on viinud meeste suure ülekaaluni Hiina ja India rahvastikus ning toidab kuritegevuse ja terrorismi kasvu. Ühe lapse poliitika. Lisa: Kas teate. Naiste osakaal rahvastikus

  5. Noorteühenduste kogu tutvustab Euroopa Liitu / Jaanika Meier

    Index Scriptorium Estoniae

    Meier, Jaanika

    2007-01-01

    Tartu Noorteühenduste Kogu tutvustab projekti "Kodanikuna Euroopa Liidus. Eile. Täna. Homme" noortele Euroopa Liitu, selle toimemehhanisme, arengusuundi ja liidus noortele pakutavaid võimalusi. Lisa: Kas teate

  6. Muusikamaailm : Messiaeni mälestusfestival. Masuri lahkumiskontserdid USAs. Kolmest kaotusest / Priit Kuusk

    Index Scriptorium Estoniae

    Kuusk, Priit, 1938-

    2002-01-01

    Olivier Messiaeni mälestusfestivalist "musik sehen, licht hören". Kurt Masur lahkub New Yorgi Filharmoonia orkestri peadirigendi ametist. Teated Xavier Montsalvatge, Dorothy DeLay ja Dzhansug Kahhidze surmast

  7. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  8. Genetic parameters and genetic trends in the Chinese × European Tiameslan composite pig line. II. Genetic trends

    Directory of Open Access Journals (Sweden)

    Legault Christian

    2000-01-01

    Full Text Available Abstract The Tiameslan line was created between 1983 and 1985 by mating Meishan × Jiaxing crossbred Chinese boars with sows from the Laconie composite male line. The Tiameslan line has been selected since then on an index combining average backfat thickness (ABT and days from 20 to 100 kg (DT. Direct and correlated responses to 11 years of selection were estimated using BLUP methodology applied to a multiple trait animal model. A total of 11 traits were considered, i.e.: ABT, DT, body weight at 4 (W4w, 8 (W8w and 22 (W22w weeks of age, teat number (TEAT, number of good teats (GTEAT, total number of piglets born (TNB, born alive (NBA and weaned (NW per litter, and birth to weaning survival rate (SURV. Performance data from a total of 4 881 males and 4 799 females from 1 341 litters were analysed. The models included both direct and maternal effects for ABT, W4w and W8w. Male and female performances were considered as different traits for W22w, DT and ABT. Genetic parameters estimated in another paper (Zhang et al., Genet. Sel. Evol. 32 (2000 41-56 were used to perform the analyses. Favourable phenotypic (ΔP and direct genetic trends (ΔGd were obtained for post-weaning growth traits and ABT. Trends for maternal effects were limited. Phenotypic and genetic trends were larger in females than in males for ABT (e.g. ΔGd = -0.48 vs. -0.38 mm/year, were larger in males for W22w (ΔGd = 0.90 vs. 0.58 kg/year and were similar in both sexes for DT (ΔGd = -0.54 vs. -0.55 day/year. Phenotypic and genetic trends were slightly favourable for W4w, W8w, TEAT and GTEAT and close to zero for reproductive traits.

  9. 2006 - veel üks raisatud aasta Euroopa tugevdamisel? / Jeroen Bult

    Index Scriptorium Estoniae

    Bult, Jeroen

    2006-01-01

    Ilmunud ka: Postimees : na russkom jazõke 9. jaan. lk. 8. 2005. aasta kujunes Euroopa Liidule kriisiaastaks. Autor on seisukohal, et maailmapoliitikas osalemiseks peab ühendus lõpetama sisetülid. Lisa: Kas teate?

  10. Wasps are the cause of an increasing mastitis problem in dairy cattle in Israel.

    Science.gov (United States)

    Yeruham, I; Braverman, Y; Schwimmer, A

    1998-07-01

    The German wasp Vespula germanica (Fabr.) (Hymenoptera: Vespidae) has been observed to injure dairy cows teats, causing lesions which can lead to mastitis. The number of dairy herds in Israel reported to be affected in this way has increased from five prior to 1989 to 32 from 1989 to 1993. Likewise, the geographical distribution of the colonies of these wasps has expanded from the Galilee to the northern Negev. Most cases of mastitis appeared during August and September when the wasps were most active; the predominant organism isolated was Streptococcus dysgalactiae. Apparently the wasps served as a vector in spreading S. dysgalactiae infection in the herds. More adult cows than first-calving cows were affected. The teats of the front quarters were more affected than those of the hind quarters.

  11. Effect of Gd2O3 doping on structure and boron volatility of borosilicate glass sealants in solid oxide fuel cells-A study on the La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF) cathode

    Science.gov (United States)

    Zhang, Qi; Tan, Shengwei; Ren, Mengyuan; Yang, Hsiwen; Tang, Dian; Chen, Kongfa; Zhang, Teng; Jiang, San Ping

    2018-04-01

    Boron volatility is one of the most important properties of borosilicate-based glass sealants in solid oxide fuel cells (SOFCs), as boron contaminants react with lanthanum-containing cathodes, forming LaBO3 and degrading the activity of SOFCs. Here, we report that the reaction between the volatile boron and a La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF) cathode during polarization can be significantly reduced by doping aluminoborosilicate glass with Gd2O3. Specifically, the Gd cations in glass with 2 mol.% Gd2O3 dissolve preferentially in the borate-rich environment to form more Gd-metaborate structures and promote the formation of calcium metaborate (CaB2O4); they also condense the B-O network after heat treatment, which suppresses poisoning by boron contaminants on the LSCF cathode. The results provide insights into design and development of a reliable sealing glass for SOFC applications.

  12. Ekspert : kõhklejad otsustavad Soome järgmise presidendi / Risto Uimonen ; interv. Erkki Bahovski

    Index Scriptorium Estoniae

    Uimonen, Risto

    2006-01-01

    Soome ajalehe Kaleva peatoimetaja prognoosib Soome presidendivalimiste teise vooru võimalikke tulemusi ning selgitab, millised teemad on leidnud kajastamist valimiskampaanias. Lisa: Kas teate? Vt. samas: Erkki Bahovski. Halonen ja Niinistö võitlevad viimse higipiisani

  13. 12904 ANIMAL HEALTH MANAGEMENT PRACTICES IN ZERO ...

    African Journals Online (AJOL)

    Poor hygiene of the enclosures and washing the udders instead of teats only may predispose animals to ... management including provision of good quality nutritious feed, clean water, ... antibiotics for prevention and treatment of diseases [7].

  14. Superomniphobic Surfaces for Military Applications: Nano- and Micro-Fabrication Methods: Year Two Report

    Science.gov (United States)

    2011-12-01

    thread locking adhesive and advertised as waterproof) and Fluonova’s Fluorinated Polyurethane (2k 4FVBA) sealant (fluoropolymers adhesive/sealant for...bonding to most surfaces Advertised as being a water proof adhesive When cured, its consistency is very hard and unaffected by a variety of...polar fluorinated products; therefore, can only be used in small quantities. Yellow in colour . Not developed for coating/spray applications

  15. Mõte mõlgutab kuuli kerre / Priit Ennet

    Index Scriptorium Estoniae

    Ennet, Priit

    2008-01-01

    Kaugemas tulevikus võiks asjatundjate arvates ainuüksi mõtte jõul suunata sõjatehnika tööd - 128 sensori abil registreerib kiiver sõjamehe ajusignaalid ja edestab neist saadud teated kaasvõitlejate kõrvaklappidesse

  16. Kolmandiku võrra kasvanud Visa kasum jäi ikka napiks / Virge Lahe

    Index Scriptorium Estoniae

    Lahe, Virge

    2008-01-01

    Maksekaardivõrgu Visa Inc. kasum kasvas esimeses kvartalis pea kolmandiku, ent aktsia kukkus teate peale 7%, kuna oodati märksa paremaid uudiseid. Diagramm: Visa aktsia hind. Vt. samas: Visa on kaarditasude pärast uurimise all

  17. Must kalamari kallineb / Aleksei Günter

    Index Scriptorium Estoniae

    Günter, Aleksei, 1979-

    2006-01-01

    3. jaanuaril teatas ohustatud liikidega kauplemist reguleeriv rahvusvaheline keskkonnaorganisatsioon CITES, et ei kinnita kaaviari ekspordikvoote 2006. aastaks enne, kui tootjariigid esitavad piisavalt tõendeid, et tuuraliste püük ei ohusta seda hinnalist liiki. Lisa: Kas teate?

  18. Study on durability for thermal cycle of planar SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Motoo; Nakata, Kei-ichi; Wakayama, Sin-ichi [Tonen Corp., Saitama (Japan)] [and others

    1996-12-31

    TONEN CORPORATION has developed planar type SOFC since 1986. We demonstrated the output of 1.3 kW in 1991 and 5.1 kW in 1995. Simultaneously we have studied how to raise electric efficiency and reliability utilizing hydrogen and propane as fuel. Durability for thermal cycle is one of the most important problems of planar SOFC to make it more practical. The planar type SOFC is made up of separator, zirconia electrolyte and glass sealant. The thermal expansion of these components are expected to be the same value, however, they still possess small differences. In this situation, a thermal cycle causes a thermal stress due to the difference of the cell components and is often followed by a rupture in cell components, therefore, the analysis of the thermal stress should give us much useful information. The thermal cycle process consists of a heating up and cooling down procedure. Zirconia electrolyte is not bonded to the separator under the condition of the initial heating up procedure, and glass sealant becomes soft or melts and glass seals spaces between the zirconia and separator. The glass sealant becomes harder with the cooling down procedure. Moreover, zirconia is tightly bonded with separator below a temperature which is defined as a constraint temperature and thermal stress also occurs. This indicates that the heating up process relaxes the thermal stress and the cooling down increases it. In this paper, we simulated dependence of the stress on the sealing configuration, thermal expansion of sealant and constraint temperature of sealant glass. Furthermore, we presented SOFC electrical properties after a thermal cycle.

  19. Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units.

    Science.gov (United States)

    Lucey, Siobhan M; Santini, Ario; Roebuck, Elizabeth M

    2015-03-01

    There is a lack of data on polymerization of resin-based materials (RBMs) used in paediatric dentistry, using dual-peak light-emitting diode (LED) light-curing units (LCUs). To evaluate the degree of conversion (DC) of RBMs cured with dual-peak or single-peak LED LCUs. Samples of Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) and fissure sealants Delton Clear and Delton Opaque (Dentsply) were prepared (n = 3 per group) and cured with either one of two dual-peak LCUs (bluephase(®) G2; Ivoclar Vivadent or Valo; Ultradent) or a single-peak (bluephase(®) ; Ivoclar Vivadent). High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of initiators other than camphorquinone. The DC was determined using micro-Raman spectroscopy. Data were analysed using general linear model anova; α = 0.05. With Herculite XRV Ultra, the single-peak LCU gave higher DC values than either of the two dual-peak LCUs (P < 0.05). Both fissure sealants showed higher DC compared with the two RBMs (P < 0.05); the DC at the bottom of the clear sealant was greater than the opaque sealant, (P < 0.05). 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin(®) TPO) was found only in Vit-l-escence. Dual-peak LED LCUs may not be best suited for curing non-Lucirin(®) TPO-containing materials. A clear sealant showed a better cure throughout the material and may be more appropriate than opaque versions in deep fissures. © 2014 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. The analysis of variability of pH level and somatic cell count (SCC ...

    African Journals Online (AJOL)

    ) in sowsf colostrum and milk depending on the reproductive cycle, litter size and consecutive pair of teats. The animal specimens were 30 sows of the Zlotnicka White breed. Z.otnicka pigs were subjected to the National Genetic Resources ...

  1. A unique heterologous fibrin sealant (HFS) as a candidate biological scaffold for mesenchymal stem cells in osteoporotic rats.

    Science.gov (United States)

    Orsi, Patrícia Rodrigues; Landim-Alvarenga, Fernanda Cruz; Justulin, Luis Antônio; Kaneno, Ramon; de Assis Golim, Marjorie; Dos Santos, Daniela Carvalho; Creste, Camila Fernanda Zorzella; Oba, Eunice; Maia, Leandro; Barraviera, Benedito; Ferreira, Rui Seabra

    2017-09-29

    The injection of mesenchymal stem cells (MSCs) directly into the bone of osteoporotic (OP) patients for rapid recovery has been studied worldwide. Scaffolds associated with MSCs are used to maintain and avoid cell loss after application. A unique heterologous fibrin sealant (HFS) derived from snake venom was evaluated for the cytotoxicity of its main components and as a three-dimensional biological scaffold for MSCs to repair a critical femur defect in osteoporotic rats. The cytotoxicity of HFS was assessed using a 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazoliumbromide (MTT) assay and transmission electron microscopy. The cells were cultured, characterized by flow cytometry and differentiated into the osteogenic lineage. Two-month-old rats underwent ovariectomy to induce OP. After 3 months, a 5 mm critical bone defect was made in the distal end of the rat femurs and filled with HFS; HFS + MSCs; and HFS + MSCs D (differentiated into the osteogenic lineage) to evaluate the effects. An injury control group (injury and no treatment) and blank control group (no injury and no treatment) were also included. The animals were observed at days 14 and 28 by microtomographic (micro-CT) analyses, histologic and biochemical analysis, as well as scanning electron microscopy. The results revealed that one of the compounds of HFS, the thrombin-like enzyme extracted from snake venom, had no cytotoxic effects on the MSCs. OP was successfully induced, as demonstrated by the significant differences in the levels of 17β-estradiol, Micro-CT analyses and alkaline phosphatase between the ovariectomized (OVX) and non-ovariectomized (NOVX) groups. The histological data revealed that at 14 days after surgery in both the OVX and NOVX animals, the HFS + CTMs and HFS + CTMsD showed a higher formation of bone cells at the site in relation to the control group (without treatment). Collagen formation was evidenced through bone neoformation in all treated and control groups

  2. A randomized clinical trial on the sealing of occlusal carious lesions

    DEFF Research Database (Denmark)

    Alves, Luana Severo; Giongo, Fernanda Cristina Mendes de Santa; Mua, Bruna

    2017-01-01

    This randomized clinical trial aimed to assess the efficacy of sealing occlusal carious lesions in permanent teeth. The sample consisted of 54 occlusal carious lesions in permanent molars and premolars of 49 patients aged 8-43 years (median: 19 years). The inclusion criteria comprised the presence...... of a cavity with no access allowing biofilm control. The maximum depth of the lesion was the middle third of the dentin thickness, as assessed by bitewing radiography. The teeth were randomly assigned to sealant treatment (n = 28) or restorative treatment (n = 26). Clinical and radiographic examinations were...... performed after 1 year and after 3-4 years. The outcomes depended on the clinical performance of the sealant/restoration and the control of caries progression observed radiographically. Survival analysis was performed to assess success rates. Over the 3-4 years of monitoring, 2 sealants were totally lost, 1...

  3. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  4. [Comparative studies on fissure sealing: composite versus Cermet cement].

    Science.gov (United States)

    Hickel, R; Voss, A

    1989-06-01

    Fifty two molars sealed with either composite or Cermet cement were compared. The composite sealant was applied after enamel etching using a rubber dam. Before sealing with Cermet cement the enamel was only cleaned with pumice powder and sodium hypochlorie and the material was applied without enamel etching. After an average follow-up of 1.6 years composite sealants proved to be significantly more reliable. Cermet cement sealings showed defects more frequently.

  5. Palts ja Peek seljatasid maksuameti / Lauri Linnamäe

    Index Scriptorium Estoniae

    Linnamäe, Lauri

    2007-01-01

    Riigikohtu otsus maksuameti edasikaebust mitte arutada ja jätta jõusse Tallinna ringkonnakohtu otsus võttis Tõnis Paltsult ja Toomas Peegilt maksupetturluse süüdistuse seoses sidefirma AS Levicomi müügiga Tele2 kontsernile. Lisatud: kas teate?

  6. Globaalne peastsoojenemine : Bangkok / Mai Loog

    Index Scriptorium Estoniae

    Loog, Mai, 1960-

    2006-01-01

    Dan Browni samanimelise romaani järgi valminud põnevusfilm "Da Vinci kood" : režissöör Ron Howard : Ameerika Ühendriigid 2006. Tais lisati filmi algusse ja lõppu hoiatavad teated, et tegemist on väljamõeldisega

  7. Process for teating whey by enzymic hydrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Nocquet, J L

    1980-01-01

    In the process lactose is converted into glucose and galactose, with demineralization to a level of at least 50%, before the hydrolysis. A bacteriologically stable hydrolysed whey is obtained and may be used in foods for human consumption.

  8. Animal Welfare and Economic Aspects of Using Nurse Sows in Swedish Pig Production

    Directory of Open Access Journals (Sweden)

    Karin Alvåsen

    2017-12-01

    Full Text Available The number of born piglets per litter has increased in Swedish pig industry, and farmers are struggling to improve piglet survival. A common practice is to make litters more equally sized by moving piglets from large litters to smaller to make sure that all piglets get an own teat to suckle. Litter equalization is not always enough, as many sows have large litters and/or damaged teats, which results in an insufficient number of available teats. One way to solve this problem is to use nurse sows. A nurse sow raises, and weans, her own piglets before receiving a foster litter. The objectives of this study were to address how the use of nurse sows affects the welfare of sows and piglets and to explore how it impacts the contribution margin of pig production in Sweden. A literature search was made to investigate welfare aspects on sows and piglets. As there were few published studies on nurse sows, an expert group meeting was organized. In order to explore the impact on the contribution margin of pig production, a partial budgeting approach with stochastic elements was used for a fictive pig farm. Standard templates for calculating costs and benefits were supplemented with figures from existing literature and the gathered expert opinions. In Sweden, the minimum suckling period is 28 days while published studies involving nurse sows, all from outside of Sweden, weaned the piglets at 21 days. A Swedish nurse sow will thus get longer lactation period which might increase the risk of poor body condition, damaged teats, and shoulder ulcers. This indicates a reduced welfare of the sow and may lead to impaired fertility and increased culling risk. On the other hand, the piglet mortality could be reduced with the use of nurse sows, but the separation and mixing of piglets could be stressful. The partial budgeting suggested that the nurse sow system is slightly more profitable (+6,838 Swedish krona per farrowing group during one dry and one lactation

  9. Maailma mõjukaim välisminister ja naine Condoleezza Rice / Evelyn Kaldoja

    Index Scriptorium Estoniae

    Kaldoja, Evelyn, 1980-

    2005-01-01

    Ajakirja Forbes poolt koostatud saja maailma mõjukama naise edetabelit juhib USA välisminister Condoleezza Rice. Välisministri edu on taganud tema töökus, hea suhtlemisoskus, maitsekas riietumisstiil ning hea läbisaamine president George Bushiga. Lisa: Kas teate?

  10. Gruusia sammub Eesti reformide jälgedes / Nino Burdžanadze ; intervjueerinud Kaarel Kaas

    Index Scriptorium Estoniae

    Burdžanadze, Nino

    2006-01-01

    30. ja 31. mail Eestis viibinud Gruusia parlamendi esimehe Nino Burdžanadze sõnul võtab Gruusia uuendusi läbides eeskuju eelkõige Baltimaadest ning ta usub, et Gruusia suhted Venemaaga paranevad pärast NATO-sse astumist. Lisa: Kas teate?

  11. Mastitis in sheep--The last 10 years and the future of research.

    Science.gov (United States)

    Gelasakis, A I; Mavrogianni, V S; Petridis, I G; Vasileiou, N G C; Fthenakis, G C

    2015-12-14

    Bacterial mastitis is a significant welfare and financial problem in sheep flocks. This paper reviews the recently published literature, including publications that highlight the significance and virulence factors of the causal agents, especially Staphylococcus aureus and Mannheimia haemolytica, the primary causes of the disease. Research has also contributed to the understanding of risk factors, including genetic susceptibility of animals to infections, supporting future strategies for sustainable disease control. Pathogenetic mechanisms, including the role of the local defenses in the teat, have also been described and can assist formulation of strategies that induce local immune responses in the teat of ewes. Further to well-established diagnostic techniques, i.e., bacteriological tests and somatic cell counting, advanced methodologies, e.g., proteomics technologies, will likely contribute to more rapid and accurate diagnostics, in turn enhancing mastitis control efforts. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Measuring quality of dental care: Caries prevention services for children.

    Science.gov (United States)

    Herndon, Jill Boylston; Tomar, Scott L; Catalanotto, Frank A; Rudner, Nancy; Huang, I-Chan; Aravamudhan, Krishna; Shenkman, Elizabeth A; Crall, James J

    2015-08-01

    The authors conducted a study to validate the following 3 evidence-based, process-of-care quality measures focused on dental caries prevention for children with an elevated risk of experiencing caries: sealants for 6- to 9-year-olds, sealants for 10- to 14-year-olds, and topical fluoride. Using evidence-based guidelines, the Dental Quality Alliance developed measures for implementation with administrative data at the plan and program levels. To validate the measures, the authors used data from the Florida and Texas Medicaid programs and Children's Health Insurance Programs and from national commercial dental benefit plans. Data were extracted from 414 randomly selected dental office records to validate the use of administrative data to accurately calculate the measures. The authors also assessed statistically significant variations in overall measure performance. Agreement between administrative data and dental records was 95% for sealants (κ = 0.82) and 90% for topical fluoride (κ = 0.78). Sensitivity and specificity were 90.7% and 88.5% for topical fluoride and 77.8% and 98.8% for sealants, respectively. Variation in overall measure performance was greatest for topical fluoride (χ(2) = 5,887.1; P caries received at least 2 topical fluoride applications during the reporting year. Although there was greater variation in performance for sealants for 6- to 9-year-olds (range, 21.0-31.3%; χ(2) = 548.6; P caries prevention process-of-care quality measures can be implemented feasibly and validly using administrative claims data. The measures can be used to assess, monitor, and improve the proportion of children with an elevated risk of experiencing dental caries who receive evidence-based caries prevention services. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  13. INHIBITION OF Malus sylvestris Mill. PEELEXTRACT USING ETANOL SOLVENT ON THE GROWTH OF Streptococcus agalactiae AND Escherichia coli CAUSING MASTITIS

    Directory of Open Access Journals (Sweden)

    Kanzul Kamal Putra

    2017-03-01

    Full Text Available The purpose of this research was to find the resistibility of Manalagi apple peel extract, using etanol, to the growth of was to determine the antibacterial activity of Manalagi apple peel (Malus sylvestris Mill extract in various solvent using ethanol concentration against the growth of Streptococcus agalactiae and Escherichia coli bacteria that causing mastitis.The research methodwas experimental using Completely Randomized Design with 4 treatments and 6 replication. The treatments consisted of P1 (10%, P2 (20%, P3 (50% concentrations and P0 (10% iodips as the control. The variable measured was diameter of inhibition zone. The data were analyzed using ANOVA and continued by Duncan’s New Multiple Range Test (DMRT test if there was significantly difference result. The result of the inhibition zone of Manalagi apple peel extract using etanol in preventing the growth of Streptococcus agalactiae and Escherichia coli bacteria was different (P<0,01. In P2 (30% concentration, the extract resistibility to the growth of Streptococcus agalactiae bacteria was equivalent to P0 (iodips and in P3 (50% concentration, the extract resistibility to Escherichia coli bacteria was greater than P0 (iodips. Manalagi apple peel extract using etanol can be used as a natural antiseptic solution for teat dipping on dairy cows. The recommendation from the research was using extract Manalagi apple peel with etanol solvent concentration of 30% as a solution of teat dipping.   Keywords : Manalagi apple peel, Teat dipping, Mastitis, Streptococcus agalactiaeand Escherichia coli

  14. Intramammary infection with coagulase-negative staphylococci at parturition: Species-specific prevalence, risk factors, and effect on udder health.

    Science.gov (United States)

    De Visscher, A; Piepers, S; Haesebrouck, F; De Vliegher, S

    2016-08-01

    Coagulase-negative staphylococci (CNS) are the main cause of bovine intramammary infections (IMI) in many countries. Despite a high prevalence of CNS IMI at parturition, species-specific risk factor studies, relying on accurate identification methods, are lacking. Therefore, this observational study aimed at determining the prevalence and distribution of different CNS species causing IMI in fresh heifers and dairy cows in Flemish dairy herds and identifying associated species- and subgroup-specific risk factors at the herd, cow, and quarter level. The effect on udder health was investigated as well. Staphylococcus chromogenes, S. sciuri, and S. cohnii were the most frequently isolated species. The only CNS species causing IMI in fresh heifers and dairy cows in all herds was Staphylococcus chromogenes, whereas large between-herd differences in distribution were observed for the other species. Quarters from heifers and quarters with an inverted teat end had higher odds of being infected with S. chromogenes, S. simulans, or S. xylosus as well as with S. chromogenes solely. Prepartum teat apex colonization with S. chromogenes increased the likelihood of S. chromogenes IMI in the corresponding quarters at parturition. Quarters with dirty teat apices before calving were more likely to be infected with S. cohnii, S. equorum, S. saprophyticus, or S. sciuri, supporting the environmental nature of these CNS species. Three species (S. chromogenes, S. simulans, and S. xylosus) were associated with a higher quarter somatic cell count at parturition as compared with uninfected quarters. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Comparison of external udder measurements of the sheep breeds Improved Valachian, Tsigai, Lacaune and their crosses

    Directory of Open Access Journals (Sweden)

    Pavol Makovický

    2013-12-01

    Full Text Available Morphological udder traits have recently become of greater interest from farmers to researchers. In dairy ewes, the udder is very important due to its physiological and conformational characteristics. External udder traits were measured in ewes (Ovis aries L. of nine genotypes (355 ewes created of the basis of Improved Valachian (IV, Tsigai (T, and Lacaune (LC breeds (six traits; 1185 data for each trait during the milking period 2002-2008. Udder measurements were assessed for: udder length (UL, udder width (UW, rear udder depth (RUD, cistern depth (CDE, teat length (TL, and teat angle (TA. Data were processed by restricted maximum likelihood (REML methodology using a MIXED procedure from the SAS statistical package. All studied parameters were influenced by the genotype (P < 0.001, many of them also by the effect of parity and lactation stage. The exactly detected UL, UW and RUD during the lactation and with the age of ewes expand gradually (P < 0.001. Teat length was greater in older ewes (expanding, with the parity. Indicator TA during lactation worsened. Crosses with 25 to 75% share of genetic dairy breeds (in particular with LC, to a lesser extent 'East Friesian' -EF were in most cases larger than the udder cisterns of purebred ewes T and IV. Purebred LC had the largest udders, with the largest cisterns. In conclusion, crosses with specialized dairy breeds have more suitable udders for machine milking than purebred default breeds (T, IV, LC and are suitable for machine milking.

  16. Multiple lead seal assembly for a liquid-metal-cooled fast-breeder nuclear reactor

    International Nuclear Information System (INIS)

    Hutter, E.; Pardini, J.A.

    1977-01-01

    A reusable multiple lead seal assembly provides leak-free passage of stainless-steel-clad instrument leads through the cover on the primary tank of a liquid-metal-cooled fast-breeder nuclear reactor. The seal isolates radioactive argon cover gas and sodium vapor within the primary tank from the exterior atmosphere and permits reuse of the assembly and the stainless-steel-clad instrument leads. Leads are placed in flutes in a seal body, and a seal shell is then placed around the seal body. Circumferential channels in the body and inner surface of the shell are contiguous and together form a conduit which intersects each of the flutes, placing them in communication with a port through the wall of the seal shell. Liquid silicone rubber sealant is injected into the flutes through the port and conduit; the sealant fills the space in the flutes not occupied by the leads themselves and dries to a rubbery hardness. A nut, threaded onto a portion of the seal body not covered by the seal shell, jacks the body out of the shell and shears the sealant without damage to the body, shell, or leads. The leads may then be removed from the body. The sheared sealant is cleaned from the body, leads, and shell and the assembly may then be reused with the same or different leads. 3 claims, 6 figures

  17. Revegetation/rock cover for stabilization of inactive U-tailings sites

    International Nuclear Information System (INIS)

    Beedlow, P.A.; Cadwell, L.L.

    1982-01-01

    Soil placed over any sealant/barrier system can provide a protective mantle if the soil is not lost by erosion. Vegetation is an attractive choice for controlling erosion because it can provide an economic self-renewing cover that serves to reduce erosion by both wind and water. Vegetation alone, however, may not adequately stabilize the surface in extremely arid areas. In those areas, a properly designed surface treatment of rock cover, perhaps in conjunction with vegetation, may be necessary to stabilize the tailings surfaces. The objective of this program is to establish guidelines for surface stabilization that are compatible with sealant/barrier systems and that are suited to soils and climates at inactive uranium mill tailings sites. These guidelines will provide the means to estimate potential vegetation cover, potential erosion, effects of surface treatments on sealant/barrier systems, and costs of vegetation and rock covers. Methods for establishing vegetation on sealed tailings will also be provided

  18. Trans-sphenoidal treatment of postsurgical cerebrospinal fluid fistula: CT-guided closure

    International Nuclear Information System (INIS)

    Floris, R.; Salvatore, C.; Simonetti, G.

    1998-01-01

    Cerebrospinal fluid (CSF) leakage after trans-sphenoidal surgery is a troublesome complication with a risk of meningitis and pneumocephalus. We suggest CT-guided intrasphenoidal injection of fibrin sealant through a 12-gauge needle as a simple alternative to surgical management of CSF fistulae. We treated eight patients, operated via the trans-sphenoidal route (five pituitary adenomas, three craniopharyngiomas), for a postoperative CSF leak by CT-guided intrasphenoidal injection of fibrin sealant alone in three cases and fibrin sealant and autologous blood in 5. CT was obtained 10 days after the procedure in all cases. In four patients, the CSF leak was closed successfully at the first attempt. The procedure was repeated on the four remaining patients because only a reduction in leakage was obtained at the first attempt. This procedure preserves olfaction and avoids the risk of frontal lobe damage. It could therefore represent the treatment of choice in many cases of anterior cranial fossa postsurgical CSF leaks. (orig.) (orig.)

  19. Expression of acute phase proteins and inflammatory cytokines in mouse mammary gland following Staphylococcus aureus challenge and in response to milk accumulation

    DEFF Research Database (Denmark)

    Nazemi, Sasan; Aalbæk, Bent; Kjelgaard-Hansen, Mads

    2014-01-01

    We used a mouse model of pathogenic (Staphylococcus aureus) and non-pathogenic (teat sealing) mammary inflammation to investigate mRNA expression of several inflammatory cytokines and acute phase proteins (APP) in mammary tissue and liver, and the appearance of some of these factors in plasma and...

  20. Extended antibiotic treatment of persistent bovine mastitis during lactation : Efficacy, economics and social influences

    NARCIS (Netherlands)

    Swinkels, J.M.

    2014-01-01

    Mastitis is an inflammation of the udder caused by bacteria that invade the udder through the teat canal, causing either persistent intramammary infections, or short, transient infections. Mastitis is the most costly disease on a dairy farm because it directly affects the production of milk, the

  1. Radioimmunoassay measurement of plasma oxytocin and vasopressin in cows during machine milking

    Energy Technology Data Exchange (ETDEWEB)

    Landgraf, R; Wehowsky, G; Schulz, J; Schulze, H; Bothur, D [Forschungsinstitut fuer Koerperkultur und Sport, Leipzig (German Democratic Republic); Karl-Marx-Universitaet, Leipzig (German Democratic Republic). Sektion Tierproduktion und Veterinaermedizin)

    1982-07-01

    The response of plasma oxytocin and vasopressin to machine milking in cows was studied by radioimmunoassay. Depending on the method of machine milking used, plasma oxytocin increased to a greater or lesser degree after teat cup application. Plasma vasopressin was not affected by the milking procedures.

  2. Atraumatic restorative treatment in Brazilian schoolchildren: 12 months preliminary clinical results

    OpenAIRE

    Sacramento, Patrícia Almada; Department of Children’s Dentistry – Division of Pediatric Dentistry – Piracicaba Dental School – University of Campinas – Piracicaba – SP – Brazil.; Borges, Ana Flávia Sanches; Department of Operative Dentistry, Endodontics and Dental Materials – Bauru Dental School – University of São Paulo – Bauru – SP – Brazil.; Rodrigues, Raphaela Farias; Department of Operative Dentistry, Endodontics and Dental Materials – Bauru Dental School – University of São Paulo – Bauru – SP – Brazil.; Puppin-Rontani, Regina Maria; Department of Children’s Dentistry – Division of Pediatric Dentistry – Piracicaba Dental School – University of Campinas – Piracicaba – SP – Brazil.

    2014-01-01

    Objective: To evaluate the clinical efficacy between two GICs, Fuji IX (GC Int. Corp.) and Ketac Molar (3M ESPE), used in Atraumatic Restorative Treatments (ART).Materials and Methods: A total of 82 children age between 6 and 9 years old are included in this study. The materials criteria application followed the “split mouth” design, 71 restorations and 98 sealants were carried out with the Fuji IX in the left hemi arches and 70 restorations and 99 sealants were carried out with the Ketac Mol...

  3. 10 aastat - 30 ettevõtet : KPMG kogemus tasakaalus tulemuskaardiga / Jüri Sakkeus

    Index Scriptorium Estoniae

    Sakkeus, Jüri

    2008-01-01

    Tasakaalus tulemuskaardi koostamise ja rakendamise nõuded, selle plussid ja miinused ning mõju ettevõtte arengule. Vt. samas: Tarmo Noop. Loon süsteemi, mis töötab ise; Kaido Kangur. Kas teate, millal teie äri kokku kukub?; Marko Rillo. Tasakaalus tulemuskaardi sobivusest ja mittesobivusest. Skeemid

  4. Sealing versus Nonsealing: Cost-benefit analysis

    Directory of Open Access Journals (Sweden)

    Anshula N Deshpande

    2016-01-01

    Full Text Available Dental caries still remains the second most prevalent disease after common cold, out of which occlusal caries is the most profound one. In India, more than 40% of children are found to be affected by dental caries. Occlusal surfaces of the teeth are most susceptible sites for caries development due to their morphology. They are least benefited from fluoride application. Various efforts have been made by the preventive means to decline the rate of caries, one of which being sealant application. Sealants have come into existence long back since 1971 when first pit and fissure sealant Nuva-Caulk came into existence. There have been piles of literature stating the benefits that arrive from sealing the teeth. However, one crucial point that is being missed most of the times is the cost-effectiveness of the sealant. There are various schools of thoughts, regarding this that is controversial ones. Some of the analysts believe that always sealing may be a bit costlier, but it reduces subsequent dental treatments and hence saves money as well as time. However, some believe that why to unnecessarily seal the teeth in all cases even when the child is not at a risk to develop caries. Hence, we need to foresee both the sides of equation. For best clinical practice and decision-making, we need to have a balance of best evidence, clinical judgment, and the most important, patient needs and preferences.

  5. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement

    Science.gov (United States)

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH8) in the 0.03-m samples above sealed lots (1320 ng m-3) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m-3). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m-3) was five times greater than above unsealed lots (26.0 ng m-3). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m-2 h-1, respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces.

  6. Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Camillo ANAUATE-NETTO

    Full Text Available Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL and contralateral teeth receiving Icon infiltrant (DMG. Caries progression was monitored by clinical (laser fluorescence caries detection and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05. No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05. SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis.

  7. Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Science.gov (United States)

    ANAUATE-NETTO, Camillo; BORELLI, Laurindo; AMORE, Ricardo; DI HIPÓLITO, Vinicius; D’ALPINO, Paulo Henrique Perlatti

    2017-01-01

    Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL) and contralateral teeth receiving Icon infiltrant (DMG). Caries progression was monitored by clinical (laser fluorescence caries detection) and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05). No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05). SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis. PMID:28877284

  8. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  9. Genetic parameters of linear conformation type traits and their relationship with milk yield throughout lactation in mixed-breed dairy goats.

    Science.gov (United States)

    McLaren, A; Mucha, S; Mrode, R; Coffey, M; Conington, J

    2016-07-01

    Conformation traits are of interest to many dairy goat breeders not only as descriptive traits in their own right, but also because of their influence on production, longevity, and profitability. If these traits are to be considered for inclusion in future dairy goat breeding programs, relationships between them and production traits such as milk yield must be considered. With the increased use of regression models to estimate genetic parameters, an opportunity now exists to investigate correlations between conformation traits and milk yield throughout lactation in more detail. The aims of this study were therefore to (1) estimate genetic parameters for conformation traits in a population of crossbred dairy goats, (2) estimate correlations between all conformation traits, and (3) assess the relationship between conformation traits and milk yield throughout lactation. No information on milk composition was available. Data were collected from goats based on 2 commercial goat farms during August and September in 2013 and 2014. Ten conformation traits, relating to udder, teat, leg, and feet characteristics, were scored on a linear scale (1-9). The overall data set comprised data available for 4,229 goats, all in their first lactation. The population of goats used in the study was created using random crossings between 3 breeds: British Alpine, Saanen, and Toggenburg. In each generation, the best performing animals were selected for breeding, leading to the formation of a synthetic breed. The pedigree file used in the analyses contained sire and dam information for a total of 30,139 individuals. The models fitted relevant fixed and random effects. Heritability estimates for the conformation traits were low to moderate, ranging from 0.02 to 0.38. A range of positive and negative phenotypic and genetic correlations between the traits were observed, with the highest correlations found between udder depth and udder attachment (0.78), teat angle and teat placement (0

  10. Tritium sorption on protective coatings for concrete

    International Nuclear Information System (INIS)

    Miller, J.M.; Senohrabek, J.A.; Allsop, P.A.

    1992-11-01

    Because of the high sorption level of tritium on unprotected concrete, a program to examine the effectiveness of various concrete coatings and sealants in reducing tritium sorption was undertaken, and various exposure conditions were examined. Coatings of epoxy, polyurethane, bituminous sealant, bituminous sealant covered with polyvinylidene chloride wrap, alkyd paint, and sodium silicate were investigated with tritium (HTO) vapor concentration, humidity and contact time being varied. An exposure to HT was also carried out, and the effect of humidity on the tritium desorption rate was investigated. The relative effectiveness of the coatings was in the order of bituminous sealant + wrap > bituminous sealant > solvent-based epoxy > 100%-solids epoxy > alkyd paint > sodium silicate. The commercially available coatings for concrete resulted in tritium sorption being reduced to less than 7% of unprotected concrete. This was improved to ∼0.1% with the use of the Saran wrap (polyvinylidene chloride). The amount of tritium sorbed was proportional to tritium concentration. The total tritium sorbed decreased with an increase in humidity. A saturation effect was observed with increasing exposure time for both the coated and unprotected samples. Under the test conditions, complete saturation was not achieved within the maximum 8-hour contact time, except for the solvent-based epoxy. The desorption rate increased with a higher-humidity air purge stream. HT desorbed more rapidly than HTO, but the amount sorbed was smaller. The experimental program showed that HTO sorption by concrete can be significantly reduced with the proper choice of coating. However, tritium sorption on concrete and proposed coatings will continue to be a concern until the effects of the various conditions that affect the adsorption and desorption of tritium are firmly established for both chronic and acute tritium release conditions. Material sorption characteristics must also be considered in

  11. Veri ja üksteisemõistmine "Berlinale" võistlusekraanil / Endel Link

    Index Scriptorium Estoniae

    Link, Endel

    2002-01-01

    Berliini 52. filmifestivali filme. Sakslase T. Tykweri mängufilm "Taevas" ("Heaven"), prantsuse filmid : F. Ozoni "8 naist" ("8 femmes") ja B. Tavernier' "Läbisõidu luba" ("Laissez-passer"), inglase P. Greengrassi "Verine pühapäev" ("Bloody Sunday") ning USAst L. Hallströmi "Laevastiku teated" ("The Shipping News")

  12. Feeding and growth in a captive-born bottlenose dolphin Tursiops ...

    African Journals Online (AJOL)

    The feeding and growth of a captive-born bottlenose dolphin Tursiops trunatus calf were studied for 30 months post partum. Changes in the behaviours associated with suckling were monitored and suggested that the mammary glands need tactile stimulation before the calf can feed. The calf exhibited no teat preference ...

  13. Staphylococcus aureus in mastitic crossbreed cows and its ...

    African Journals Online (AJOL)

    mastitis. Routine pasteurization of milk should also be practiced to safeguard the public health. ... Clinical examination of the udder was based on the method previously indi- ... Briefly: quarters were washed with tap water and dried. The teat .... be in place for early detection and prompt action should be planned and imple-.

  14. Linea Trasversale, Flesh and Soul

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2003-01-01

    The following article answers the specific need of providing information to all those who continually ask, “What is Linea Trasversale (LT)?” LT was founded in 1995 as a strategy to avoid isolation, in the shadow of the educational network called University of Eurasian Theatre (Università del Teat...

  15. Systematic review of noninvasive treatments to arrest dentin non-cavitated caries lesions

    Science.gov (United States)

    de Assunção, Isauremi Vieira; da Costa, Giovanna de Fátima Alves; Borges, Boniek Castillo Dutra

    2014-01-01

    AIM: To systematically review the literature on the efficacy of noninvasive methods of arresting the progression of non-cavitated occlusal carious lesions in dentin. METHODS: The Medline/PubMed, LILACS, SciELO and Scopus databases were searched to identify relevant publications through to November 2013. Only clinical trials evaluating the ability of noninvasive methods to arrest the progression of occlusal non-cavitated carious lesions in dentin were included. Screening, data extraction and quality assessment were conducted independently and in duplicate. RESULTS: Of 167 citations identified, nine full text articles were screened and five were included in the analysis. All papers reported on occlusal fissure sealing using a self-curing glass ionomer (n = 1) or resin-based (n = 4) sealant. Only the use of resin-based sealant to obliterate occlusal fissures arrested the progression of non-cavitated occlusal carious lesions in dentin. CONCLUSION: Occlusal fissure sealing with a resin-based sealant may arrest the progression of non-cavitated occlusal dentinal caries. Further clinical trials with longer follow-up times should be performed to increase scientific evidence. PMID:24868513

  16. CMHC research project: Testing of air barriers construction details: Report

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    This project was conducted to quantify the air leakage characteristics of the header joist, the electric outlets, and the window openings in wood-frame walls. The study evaluated the sealed internal membrane method, where polyethylene sheet and sealant provide the air barrier; the external air barrier method, which uses a continuous vapour permeable membrane (spun-bonded olefin film), sandwiched between two layers of external wall sheathing; and the airtight drywall method, where the interior gypsum board finish, together with framing materials and gaskets, are used as the air barrier. In addition, the traditional approach to wood-frame wall construction, where no special attention is given to achieving a continuous air barrier, was evaluated for comparison.

  17. Võitsite Eurovisiooni ja edasi? / Wally Olins ; interv. Andri Maimets

    Index Scriptorium Estoniae

    Olins, Wally

    2005-01-01

    Firma Saffron Brand Consultants juhatuse esimees, mitme riigi turundusega tegelenud brändimeister vastab küsimustele, mis puudutavad Eesti riigi brändimist ja olemasoleva Eesti brändinguprogrammi mittetoimimist ning tutvustab oma bränditeooriat. Lisad: Kas teate?; Noppeid seminarilt "Rahvas ja bränd ning rahvas kui bränd"

  18. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement.

    Science.gov (United States)

    Van Metre, Peter C; Majewski, Michael S; Mahler, Barbara J; Foreman, William T; Braun, Christopher L; Wilson, Jennifer T; Burbank, Teresa L

    2012-06-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH(8)) in the 0.03-m samples above sealed lots (1320 ng m(-3)) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m(-3)). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m(-3)) was five times greater than above unsealed lots (26.0 ng m(-3)). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m(-2) h(-1), respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces. Published by Elsevier Ltd.

  19. The influence of toothbrushing and coffee staining on different composite surface coatings.

    Science.gov (United States)

    Zimmerli, Brigitte; Koch, Tamara; Flury, Simon; Lussi, Adrian

    2012-04-01

    The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.

  20. Internal Audit Service | Internal Audit Service

    Science.gov (United States)

    their internal auditing function in the areas of professional excellence, quality of service and Students and teachers Media Internal Audit Service Navbar Toggle Home About the Staff Risk Assessment and Planning Internal Audit Process Search for Search Home The mission of the Fermilab Internal Audit Service

  1. Lamination cooling system formation method

    Science.gov (United States)

    Rippel, Wally E [Altadena, CA; Kobayashi, Daryl M [Monrovia, CA

    2009-05-12

    An electric motor, transformer or inductor having a cooling system. A stack of laminations have apertures at least partially coincident with apertures of adjacent laminations. The apertures define straight or angled cooling-fluid passageways through the lamination stack. Gaps between the adjacent laminations are sealed by injecting a heat-cured sealant into the passageways, expelling excess sealant, and heat-curing the lamination stack. Manifold members adjoin opposite ends of the lamination stack, and each is configured with one or more cavities to act as a manifold to adjacent passageway ends. Complex manifold arrangements can create bidirectional flow in a variety of patterns.

  2. Relationship of litter size with milk yield, udder morphology and udder health of East Friesian sheep

    Directory of Open Access Journals (Sweden)

    Zvonimir Prpić

    2016-12-01

    Full Text Available The aim of this study was to determine relationship between litter size and milk yield, udder morphology, and udder health of East Friesian ewes. For that purpose a total of 80 East Friesian ewes, from 2nd to 4th lactation, with symmetrical udders, without visible (clinical signs of mastitis were involved in this study. Until weaning at average age of 60±5 days lambs suckled their mothers exclusively. During milking period regular milking controls (on a monthly basis were carried out (AT method and, on these occasions, individual milk samples for chemical composition analysis were taken. Three times per lactation (1st, 3rd and 5th milking control, prior to the milking, evaluation and measuring of udder morphology traits were performed. Also, during above-mentioned test-day controls (three times per lactation one sample of half udder milk was taken with purpose of bacterial and somatic cell counts (SCC tests. Ewes with twin and triplet lambs had significantly (P0.05 and depth (P>0.05. Besides that, udders of ewes with twins and triplets had higher cistern, greater teat angle and larger teat dimensions than ewes with singles, although those differences were not statistically significant. Ewes with single lamb had teats more (P<0.05 cranially oriented than ewes with twins and triplets. Significant (P<0.05 differences in somatic cell count (log10SCC between ewes of different litter sizes were determined, regardless of the health status of mammary gland. The higher (P<0.05 prevalence of subclinical mastitis was observed in ewes with twin and triplet lambs than in ewes with singles. In 46% of mammary glands (udder halves of sheep with twins and triplets a subclinical mastitis was established and even 65.8% of them undergone an infection of one or both halves of the udder during the milking period.

  3. International Trade. International Business

    OpenAIRE

    Мохнюк, А. М.; Mokhniuk, A. M.

    2015-01-01

    Work programme of the study course “International Trade. International Business” was prepared in accordance with educational and vocational training program for bachelors of training direction 6.030601 “Management”.

  4. Interaction between bovine-associated coagulase-negative staphylococci species and strains and bovine mammary epithelial cells reflects differences in ecology and epidemiological behavior.

    Science.gov (United States)

    Souza, F N; Piepers, S; Della Libera, A M M P; Heinemann, M B; Cerqueira, M M O P; De Vliegher, S

    2016-04-01

    Bacteria adherence seems to be an essential first stage for the internalization of bacteria into the cytoplasm of the host cell, which is considered an important virulence strategy enabling bacteria to occupy a microenvironment separated from host defense mechanisms. Thus, this study aimed to explore the difference in the capacity of 4 bovine-associated staphylococci species or strains to adhere to and internalize into bovine mammary epithelial cells (MEC). Three different isolates of coagulase-negative staphylococci (CNS) were used: one strain of Staphylococcus fleurettii isolated from sawdust and considered an environmental opportunistic bacterium, and 2 dissimilar Staphylococcus chromogenes isolates, one cultured from a heifer's teat apex (Staph. chromogenes TA) and the other originating from a chronic intramammary infection (Staph. chromogenes IM). Also, one well-characterized strain of Staphylococcus aureus (Newbould 305) was used for comparison with a major mastitis pathogen. The CNS species and strains adhered to and internalized into MEC slower than did Staph. aureus. Still, we observed high variation in adhesion and internalization capacity among the different CNS, with Staph. chromogenes IM showing a greater ability to adhere to and internalize into MEC than the 2 CNS strains isolated from extramammary habitats. In conclusion, the 3 well-characterized bovine-associated CNS species and strains originating from distinct habitats showed clear differences in their capacity to adhere to and internalize into MEC. The observed differences might be related to their diversity in ecology and epidemiological behavior. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Pakane halastas naftaohvritele / Andrus Karnau, Kärt Anvelt, Küllike Rooväli

    Index Scriptorium Estoniae

    Karnau, Andrus

    2006-01-01

    Vt. ka Postimees : na russkom jazõke 6. veebr. lk. 2. Kuigi naftatankeri Flawless kapten kinnitas Eesti merepäästjaile saadetud teates laevaõnnetuse juhtumist, eitab tankeri rentnik Hanseatic Shipping Company kütteõli sattumist merre. Vt. samas intervjuud Põhja ringkonnaprokuratuuri juhtivprokuröri Lavly Lepaga: Prokurör usub edusse. Lisa: Naftareostus

  6. Increases of Antibiotic Resistance in Excessive Use of Antibiotics in Smallholder Dairy Farms in Northern Thailand

    Directory of Open Access Journals (Sweden)

    W. Suriyasathaporn

    2012-09-01

    Full Text Available Antibiotic resistance patterns of bacterial isolates from both quarter teat-tip swabs and their quarter milk samples were evaluated in smallholder dairy farms in northern Thailand with excessive use of antibiotics (HIGH compared with normal use (NORM. Results from teat-tip swab samples showed that the percentage of Bacillus spp. resistance to overall antibiotics was significantly lower in the NORM group than that of the HIGH group, whereas, the resistance percentage of coagulase-negative staphylococci in the NORM group was higher than that of the HIGH one. The overall mastitis-causing bacteria isolated from milk samples were environmental streptococci (13.8%, coagulase-negative staphylococci (9.9%, Staphylococcus aureus (5.4%, and Corynebacterium bovis (4.5%. Both staphylococci and streptococci had significantly higher percentages of resistance to cloxacillin and oxacillin in the HIGH group when compared to the NORM one. An occurrence of vancomycin-resistant bacteria was also observed in the HIGH group. In conclusion, the smallholder dairy farms with excessive use of antibiotics had a higher probability of antibiotic-resistant pattern than the farms with normal use.

  7. Évaluation comparée des conditions de traite chez des troupeaux bovins conduits en hors sol en milieu semi-aride de Tunisie

    Directory of Open Access Journals (Sweden)

    Youssef M'SADAK

    2015-05-01

    Full Text Available The objective of this work was to evaluate the milking conditions in 120 dairy herds in three regions of the Sahel of Tunisia: Sousse, Monastir and Mahdia. For this purpose, 707 lactating cows of Holstein Friesian, were considered. The average farm size in the three areas studied was 4.6 ha. Among the surveyed farms, 71% free stall. The study of the machine operating parameters to milk cows revealed that the pulse frequency (FP, the vacuum level (NV and pulsation ratio (PR are nonconforming respectively in 87%, 78% and 58% of cases. The study of the hygienic conditions revealed that 39% of milking machines (MAT are of poor cleanliness and 51% of their pipes are in medium condition. Regarding milking practices, the most used method for cleaning teats is the collective mop with water (39%, without wiping (67%. The elimination of the first jets and the teat disinfection after milking were both omitted by 62% and 61% of farmers. The milking conditions deviate from best practice in several farms and they deserve more attention and equipment maintenance.

  8. Spordis karastunud vaim aitab kapo juhil Aldis Alusel pingeid taluda / Deivil Tserp

    Index Scriptorium Estoniae

    Tserp, Deivil, 1968-

    2006-01-01

    Kaitsepolitsei peadirektor Aldis Alus vaba aja veetmisest, spordiga tegelemisest, oma perekonnast, lapsepõlvest ning karjäärist. Lisa: Kas teate? Küsimusele, mis meenub seoses Aldis Alusega, vastavad ujumistreener Tiit Reiter, ratsutamistreener Johannes Peets ning Euroopa meister Imre Tiidemann. Vt. samas: Poolpime setukas nurjas Alusel Gruusias võistluse; Arbuusimüüja tapnuks Aluse automaadilasuga

  9. Head töötajad otsas / Robin Athey ; interv. Neeme Raud

    Index Scriptorium Estoniae

    Athey, Robin

    2006-01-01

    Konsultatsioonifirma Deloitte & Touche juhtimisuuringute analüütiku sõnul otsivad firmad väga spetsiifilise ettevalmistusega spetsialiste, keda tööjõuturul on aga raske leida. R. Athey uurimusest "On aasta 2008: kas teate, kus on teie töötajad?" Vt. samas: Näpunäide neile, kes unistavad palgatõusust ja karjäärist

  10. Tallinki esimene börsipäev pettis väikeinvestorite ootusi / Hindrek Riikoja

    Index Scriptorium Estoniae

    Riikoja, Hindrek

    2005-01-01

    Tallinki aktsia esimene börsipäev valmistas paljudele väikeinvestoritele pettumust, kuna aktsia hind tõusis päevaga vaid 58 senti ehk 0,7 protsenti. Lisa: Kas teate? Küsimusele, mida teete Tallinki aktsiatega, vastavad: ettevõtja Indrek Toome, Riigikogu liige Margus Hanson, teleprodutsent Raivo Suviste ja AS-i Biodiesel nõukogu esimees Heino Harak

  11. Development of a new concept for controlling the thermal expansion of glass ceramic composites with tailored flowability demonstrated on the example high-temperature fuel cells; Entwicklung eines neuen Konzepts zur Steuerung der thermischen Ausdehnung von glaskeramischen Verbundwerkstoffen mit angepasster Fliessfaehigkeit am Beispiel der Hochtemperatur-Brennstoffzelle

    Energy Technology Data Exchange (ETDEWEB)

    Wanko, Eric

    2011-09-26

    In the joining technology, composite materials based on glass, glass ceramics (GC) and glass ceramic composites (GCC) become more and more important. Due to the increasingly required multi-functionality of the sealant material (for e.g. coefficient of expansion, flow ability, etc..), the developed sealant material used today is based on glass ceramic composites. With these, a good adhesion of the joining components, a good flow ability of the sealant material during the joining process and a good electrical insulation and mechanical strength have to be achieved. The joining process has to take place at temperatures < 900 C. The operation conditions of the SOFC are: 600 - 800 C under oxidizing as well as reducing atmospheric conditions. The present Thesis shows that, based on the use of database and thermochemical methods, sealing materials can be swiftly adjusted to all process and operation requirements. In order to do this especially, with regards of the thermo-mechanical properties of the developed sealant material (coefficient of expansion and flow ability) during the joining process, a new concept has been designed. Joining tests have been achieved on sandwich samples. The starting point of this new concept is a metal/glass matrix composite where the coefficient of expansion was controlled by dispersing a metal phase in the glass matrix. The newly developed concept is based on glass as a matrix and a crystalline phase as a filler material. It is essential that the crystalline phase and the glass matrix composition consist of the same thermodynamic co-existence area of the selected oxide base system. Here, the glass matrix has a lower liquidus temperature compared to the crystalline filler material, while the crystalline phase which consist of a higher coefficient of expansion is used alone to tailor the coefficient of expansion of the joining material. By incorporating a single crystalline phase into the selected glass matrix, the coefficient of expansion of

  12. [Bond strengths of absorbable polylactic acid root canal post with three different adhesives].

    Science.gov (United States)

    Pan, Hui; Cheng, Can; Hu, Jia; Liu, He; Sun, Zhi-hui

    2015-12-18

    To find absorbable adhesives with suitable bonding properties for the absorbable polylactic acid root canal post. To test and compare the bond strengths of absorbable polylactic acid root canal post with three different adhesives. The absorbable polylactic acid root canal posts were used to restore the extracted teeth, using 3 different adhesives: cyanoacrylates, fibrin sealant and glass ionomer cement. The teeth were prepared into slices for micro-push-out test. The bond strength was statistically analyzed using ANOVA. The specimens were examined using microscope and the failure mode was divided into four categories: cohesive failure between absorbable polylactic acid root canal posts and adhesives, cohesive failure between dentin and adhesives, failure within the adhesives and failure within the absorbable polylactic acid root canal posts. The bond strength of cyanoacrylates [(16.83 ± 6.97) MPa] and glass ionomer cement [(12.10 ± 5.09) MPa] were significantly higher than fibrin sealant [(1.17 ± 0.50) MPa], Padhesives was 25.0%, the cohesive failure between the dentin and the adhesives was 16.7%, the failure within the adhesives was 33.3%, and the failure within the absorbable polylactic acid root canal posts was 25.0%. In the group of fibrin sealant, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 66.7%, the cohesive failure between the dentin and the adhesives was 22.2%, the failure within the adhesives was 11.1%. In the group of glass ionomer cement, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 87.5%, the failure within the adhesives was 12.5%. The major failure mode in fibrin sealant and glass ionomer cement was the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives. No major failure modes were found in the group of cyanoacrylates. The bond strength of fibrin sealant is low, which cannot meet the requirement of

  13. Nuclear fuel cycle: international market, international constraints and international cooperation

    International Nuclear Information System (INIS)

    Imai, R.

    1977-01-01

    Some of the constraints on the nuclear fuel cycle are ones arising from economic and financial reasons, those caused by uranium resources and their distribution, those arising from technical reasons, issues of public acceptance, and those quite independent of normal industrial considerations, but caused by elements of international politics. The nuclear fuel cycle and the international market, matters of nuclear non-proliferation, and international cooperation are discussed

  14. EFFECT OF SURFACE SEALING ON STAIN RESISTANCE OF A NANO-HYBRID RESIN COMPOSITE*

    Directory of Open Access Journals (Sweden)

    Günçe SAYGI

    2015-04-01

    Full Text Available Purpose: This study investigated the influence of sealant application on stain resistance of a nanohybrid resin composite compared to the efficacy of a bonding agent used as a surface sealant on prolonging color stability of the resin composite. Materials and Methods: 28 disc-shaped materials were prepared from a nano-hybrid resin composite Filtek Z550 and assigned to four groups: G1K: nonsealed; G2:Adper Single Bond; G3: Fortify ; G4: Biscover LV. After 24 h storage in distilled water at 37˚C, all specimens were subjected to thermocycling and immersed into coffee solution. Color measurements were performed using spectrophotometer (VITA Easyshade; Vident according to CIEL*a*b* system. Results: Color change values were significantly different among the groups in each evaluation period except for after thermocycling (p<0.05. For 7 days evaluation period, the difference between G3 and G4 group was statistically significant while G4 exhibited statistically significant differences (p<0.05 and p<0.0001 respectively compared to control (G1 in 14 day whereas no significant difference was found between GI and GII in 28-day evaluation period. However, ΔE values of sealed specimens (GIII, GIV differed significantly from non-sealed (GI specimens after 28 days of immersion in coffee solution (p<0.05 and p<0.0001 respectively. Conclusion: It may be concluded that using a bonding agent as a surface sealant does not increase stain resistance of resin composites of the sealants evaluated. Biscover LV showed the highest efficacy to prolong color stability of the resin composite.

  15. Udder diseases in dairy cows — field observations on incidence, somatic and environmental factors, and control

    Directory of Open Access Journals (Sweden)

    Hannu Saloniemi

    1980-03-01

    Full Text Available The incidence of udder diseases and the predisposing factors were examined in 32 herds, in a total of 500 cows. During a 3-year-period 0.32 cases of clinical mastitis occurred per cow per annum. Subclinical mastitis was detected in 61.2 % of the cows during one year. The average incidence based on a single sampling was 36.5 %. In order to obtain reliable information on the udder health of a herd the occurrence of both clinical and subclinical mastitis must be followed. Clinical cases, both those treated by a veterinarian on a farm visit and those treated by the owner according to phone prescription must be filed statistically. In this study the incidence of mastitis as reported by owner was only half of that actually detected. The incidence of teat injuries requiring veterinary treatment was 0.03 cases per cow per annum. The diagnosis »presence of bacteria» obtained from a milk sample examination using Nordic methods means according to this study in most cases the probable occurrence of infection and mastitis. Scoring of observations made from udder health, and indexes based on these scores prove to be good tools when studying relationships between udder diseases and predisposing factors. Of the somatic factors the age of the cow, stage of lactation, the distance of the rear teats from the stall floor and the position of the teats influence the incidence of mastitis. Therefore, these factors must be taken into consideration in preventive work, especially in the culling of cows. Neither teat shape nor milkability had any connection with the incidence of udder diseases. With regard to the factors in the production environment the incidence of clinical mastitis was influenced especially by the function of the milking machine. Diurnal changes in temperature, when exceeding5 degrees centigrade, increased the occurrence of mastitis. The use of a thermohygrograph is proposed in preventive work. Because of the small number of the herds only in few

  16. International Criminalization of International Terrorizm

    Directory of Open Access Journals (Sweden)

    Alexander Grigoryevich Volevodz

    2014-01-01

    Full Text Available Analysis and studying of the terrorism in all its facets is a complex entangled problem with less clear legal regulation that it might seem at first glance, especially after its transformation from local phenomenon into a world threat. Hitherto terrorism and actions connected to it have been criminalized by the majority of states. There are in modern criminal law whole systems of rules on criminal liability for terrorism which differs considerably from country to country. Terrorism has been criminalized in numerous international regional and universal antiterrorist legal instruments. The author notes that differences in definitions that are enshrined in them hinders international cooperation in criminal matters with respect to terrorist cases. Difficulties reside in the necessity to meet the dual criminality requirement and in the political offense exception. These difficulties can only be overcome through elaboration of a universally recognized definition of the notion of international terrorism and making it legally binding via its inclusion into a universal convention. The issue of definition of international terrorism is an important part of an efficient mutual assistance among states in fight against this crime. In this article the author accounts of actual ways of tackling by the international community of the issue of criminalization of international terrorism and of factors influencing them.

  17. A Huge Morel-Lavallée Lesion Treated Using a Quilting Suture Method: A Case Report and Review of the Literature.

    Science.gov (United States)

    Seo, Bommie F; Kang, In Sook; Jeong, Yeon Jin; Moon, Suk Ho

    2014-06-01

    The Morel-Lavallée lesion is a collection of serous fluid that develops after closed degloving injuries and after surgical procedures particularly in the pelvis and abdomen. It is a persistent seroma and is usually resistant to conservative methods of treatment such as percutaneous drainage and compression. Various methods of curative treatment have been reported in the literature, such as application of fibrin sealant, doxycycline, or alcohol sclerodhesis. We present a case of a huge recurrent Morel-Lavallée lesion in the lower back and buttock region that was treated with quilting sutures, fibrin sealant, and compression, with a review of the literature. © The Author(s) 2014.

  18. Influência do selante de fibrina na cicatrização das pregas vocais de suínos Influence of selant fibrin on the wound healing of the pigs vocal folds

    Directory of Open Access Journals (Sweden)

    Karla Palma Portes

    2012-02-01

    Full Text Available Os selantes de fibrina ou cola de fibrina são produtos originários de proteínas do plasma humano que mimetizam a via final da rede de coagulação. Sua aplicação para estimular a cicatrização tem sido motivo de discussão na literatura mundial. O uso do selante de fibrina em fonocirurgia tem sido realizado de modo empírico. Não há trabalhos que investiguem a ação do selante de fibrina no espaço de Reinke. OBJETIVOS: Avaliar a interferência do uso da cola de fibrina no processo de cicatrização gerado pela manipulação cirúrgica em pregas vocais de suínos. MATERIAIS E MÉTODOS: Estudo prospectivo e experimental. Seis animais tiveram ambas as pregas vocais incisadas e em apenas uma delas foi aplicado o selante, sendo que a outra serviu de controle. Após 3 meses, os animais foram sacrificados e a contagem de colágenos realizada. RESULTADOS: O lado com aplicação de cola teve média de 27,8% contra 20,4% do lado sem aplicação de cola. CONCLUSÃO: A concentração de colágeno nas amostras onde o selante de fibrina foi aplicado é significativamente maior do que nas amostras onde não houve a aplicação. Portanto, a presença do selante de fibrina estimula a fibrogênese neste tecido.Fibrin sealants or fibrin glue are products made from human plasma proteins, which mimic the final pathway of the coagulation cascade. Its application to stimulate the healing process has been a topic of debate in the literature. The use of fibrin sealants in phonosurgery has been empirical; there have been no studies that investigate the action of fibrin sealant in Reinke's space. AIM: To evaluate the effect of fibrin glue in healing of the vocal folds of pigs after surgical manipulation. MATERIALS AND METHODS: This was a prospective and experimental study. Six animals had both vocal folds incised. Sealant was applied in one of them; the other served as a control. After three months, the animals were sacrificed and a collagen count was carried

  19. IGERIA + CHUK\\VUEDO, A. A .. + ABEG :\\D

    African Journals Online (AJOL)

    BSN

    than the local br..:eds. The disease is characterized by vesicular lesions and subsequently by erosion or the epithelium of the mouth. narcs. 111u7zle. teat. udder and rumen pillars (/-crris et of. 1992: Sanson 1994). Since 193 1. virus types 0. A SAT I and S/\\T 2 have been isolated in series of outbreaks (Nawathe and Goni.

  20. Gazpromil tuleb rahast puudus kätte / Karin Volmer

    Index Scriptorium Estoniae

    Volmer, Karin

    2007-01-01

    Ilmunud ka: Postimees : na russkom jazõke 16. juuli, lk. 7.Venemaa president Vladimir Putin ja Prantsusmaa president Nicolas Sarkozy leppisid kokku, et Gazpromi partneriks seni suurimate veealuste maagaasivarude kaevandamisel Barentsi meres asuval Shtokmani leiukohal saab Prantsuse firma Total. Lisa: Kas teate? Vt. samas: Jürgen Tamme. Läänemere põhja plaanitava gaasijuhtme tulevik on ebamäärane

  1. Assessment of caries status among schoolchildren according to decayed-missing-filled teeth/decayed-extract-filled teeth index, International Caries Detection and Assessment System, and Caries Assessment Spectrum and Treatment criteria

    Directory of Open Access Journals (Sweden)

    E Rajendra Reddy

    2017-01-01

    Full Text Available Background: Detection and evaluation of dental caries is of epidemiological importance. Its early detection is important to commence appropriate treatment planning. Cavitated, noncavitated, and initial lesions of dental caries can be detected by various indices. Objectives: The objective of the study was to assess the caries experience in schoolchildren using decayed-missing-filled teeth (DMFT/decayed-extracted-filled teeth (deft, International Caries Detection and Assessment System-II (ICDAS-II, and Caries Assessment Spectrum and Treatment (CAST systems. Materials and Methods: An epidemiological survey was carried out among 1550 schoolchildren (37,644 teeth between the age ranges of 4 and 14 years. American Dental Association type III examination was performed using plane mouth mirrors and community periodontal index probes using DMFT/deft, ICDAS II, and CAST indices. Results: Out of 37,644 teeth examined, 2,718 teeth had shown caries. Caries experience with DMFT/deft index was 5.54%. Highest score of DMFT was observed in deciduous dentition period (59.02%. Overall prevalence of dental caries with ICDAS and CAST system was 6.7% and 6.95%, respectively. The highest percentage of noncavitated lesions (ICDAS - 2.26% and CAST - 3.9% and greater prevalence of caries among deciduous teeth (ICDAS - 53.2% and CAST - 58.7% was observed with both ICDAS and CAST systems. Conclusion: A high prevalence of noncavitated lesions and less number of sealants and restorations indicates the lack of awareness for prevention and treatment of oral diseases, which suggests a strong need for preventive and operative treatments.

  2. The Development of Customary International Law by International Organizations

    DEFF Research Database (Denmark)

    Odermatt, Jed

    2017-01-01

    In his Fourth Report on the Identification of Customary International Law (2016), Special Rapporteur Michael Wood confirmed that ‘[i]n certain cases, the practice of international organizations also contributes to the expression, or creation, of rules of customary international law.......’ That the practice of international organizations can be relevant when identifying customary international law is relatively uncontroversial. The practice of states within international organizations such as the UN General Assembly, for example, may contribute to the development of custom. Yet, there is little...... discussion about whether and how the practice of international organizations as such may contribute to the development of customary international law. This contribution discusses the organization that is the most capable of contributing to the development of customary international law in its own right...

  3. The international law commission and international environmental law

    International Nuclear Information System (INIS)

    Ramcharan, B.G.

    1975-01-01

    If the oceans are destroyed through pollution there will be nothing left to manage. Protection against pollution is thus a fundamental aspect of ocean management. What legal principles are available for the protection of the oceans. This paper brings together the relevant practice of the foremost international body responsible for the codification and development of international law: the International Law Commission. It describes the work of the Commission concerning: 1) pollution of the high seas; 2) pollution of international watercourses; and 3) international responsibility for environmental hazards. It concludes by expressing the hope that the Commission will further study, codify and develop international environmental law

  4. Internationalism and Globalization as Contexts for International Education

    Science.gov (United States)

    Cambridge, James; Thompson, Jeff

    2004-01-01

    A problem with the construction of an inclusive definition of international education is that the word 'international' has a variety of connotations. It is proposed that the term 'international education' is ambiguous because it appears to refer to contrasting usages in educational studies. International education is frequently discussed in the…

  5. Effective and rapid sealing of coronary, aortic and atrial suture lines †.

    Science.gov (United States)

    Skorpil, Jiri; Paraforos, Alexandros; Mandak, Jiri; Cohn, William E; Hajek, Tomas; Friedrich, Ivan

    2015-06-01

    Cardiac surgical procedures carry a high risk of perioperative bleeding. Surgical sealants are often used to prevent suture line bleeding. PreveLeak™ is a surgical sealant composed of bovine serum albumin, a polyaldehyde cross-linker, and other components that forms a soft, flexible, water-tight, mechanical seal that is biocompatible and bioresorbable. A prospective, multicentre study evaluated PreveLeak use in 44 subjects undergoing 63 cardiac procedures, primarily coronary artery bypass grafting (n = 23/63, 36.5%) and aortic valve replacement (n = 19/63, 30.2%). PreveLeak was applied to 127 suture lines and the time to sealing evaluated upon clamp release. The primary safety endpoint was the incidence of significant bleeding, infections, neurological deficits and immune/inflammatory allergic responses within 6 weeks post-treatment; subjects were followed for 3 months. Immediate sealing was achieved at all sites in 42 of 44 subjects (95.5%) and 125 of 127 treatment sites (98.4%). There were nine primary safety events: eight infections and one transient neurological deficit. Most adverse events were mild (n = 46/71, 64.8%) or moderate (n = 18/71, 25.4%) in severity. One adverse event (transient vasospasm) was considered possibly sealant-related. One death occurred due to a cardiac arrest. PreveLeak prevented bleeding at 98.4% of treated sites and was well tolerated; adverse events were consistent with those commonly observed in subjects undergoing surgical procedures. These results compared favourably with published studies of other sealants. The observed prevention of bleeding is clinically important in cardiac surgical patients. A randomized, comparative study is justified to further evaluate PreveLeak and confirm the findings from this study. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Thermal stress analysis of a planar SOFC stack

    Science.gov (United States)

    Lin, Chih-Kuang; Chen, Tsung-Ting; Chyou, Yau-Pin; Chiang, Lieh-Kwang

    The aim of this study is, by using finite element analysis (FEA), to characterize the thermal stress distribution in a planar solid oxide fuel cell (SOFC) stack during various stages. The temperature profiles generated by an integrated thermo-electrochemical model were applied to calculate the thermal stress distributions in a multiple-cell SOFC stack by using a three-dimensional (3D) FEA model. The constructed 3D FEA model consists of the complete components used in a practical SOFC stack, including positive electrode-electrolyte-negative electrode (PEN) assembly, interconnect, nickel mesh, and gas-tight glass-ceramic seals. Incorporation of the glass-ceramic sealant, which was never considered in previous studies, into the 3D FEA model would produce more realistic results in thermal stress analysis and enhance the reliability of predicting potential failure locations in an SOFC stack. The effects of stack support condition, viscous behavior of the glass-ceramic sealant, temperature gradient, and thermal expansion mismatch between components were characterized. Modeling results indicated that a change in the support condition at the bottom frame of the SOFC stack would not cause significant changes in thermal stress distribution. Thermal stress distribution did not differ significantly in each unit cell of the multiple-cell stack due to a comparable in-plane temperature profile. By considering the viscous characteristics of the glass-ceramic sealant at temperatures above the glass-transition temperature, relaxation of thermal stresses in the PEN was predicted. The thermal expansion behavior of the metallic interconnect/frame had a greater influence on the thermal stress distribution in the PEN than did that of the glass-ceramic sealant due to the domination of interconnect/frame in the volume of a planar SOFC assembly.

  7. In vitro evaluation of a novel bacteriophage cocktail as a preventative for bovine coliform mastitis.

    Science.gov (United States)

    Porter, J; Anderson, J; Carter, L; Donjacour, E; Paros, M

    2016-03-01

    The objective of this study was to investigate the potential use of bacteriophage in preventing Escherichia coli mastitis on dairies. A cocktail consisting of 4 distinct bacteriophages was generated by screening against 36 E. coli isolates from dairy cows in Washington State with clinical mastitis. The bacteriophage significantly inhibited growth of 58% of the Washington State isolates and 54% of E. coli mastitis isolates from New York State, suggesting that the cocktail of phages had a relatively broad spectrum of action against relevant strains from 2 distinct geographies. The ability to suppress bacterial growth of these isolates in a liquid growth medium was not affected by the ratio of bacteriophage particles to bacterial cells (multiplicity of infection, MOI). For those E. coli that were completely inhibited by the phage cocktail, an MOI as low as 10 had the same effect as 10 µg/mL of ceftiofur on the growth rate of E. coli over a 12-h period using optical density measurements. A 3.3- to 5.6-log reduction of growth was achieved when E. coli was co-incubated with our phage cocktail in raw milk over a 12-h period at physiologic temperature. A modified gentamicin protection assay using bovine mammary epithelial cells provided a model to test whether bacteriophage could prevent cell attachment and invasion by chronic coliform mastitis strains. Pretreatment of cell cultures with the phage cocktail significantly reduced adhesion and intracellular survival of E. coli compared with controls. When combined with a bismuth-based teat sealant, the phage cocktail was able to inhibit bacterial growth when challenged with 1.6 × 10(3) cfu/mL of a clinical mastitis E. coli strain. In vitro results show bactericidal activity by our phage in raw milk and mammary tissue culture systems. Before a bacteriophage-based dry-cow treatment becomes a potential option for dairies, in vivo studies must be able to demonstrate that a specific dose of bacteriophage can protect cows from

  8. From Public International to International Public Law: Translating World Public Opinion into International Public Authority

    NARCIS (Netherlands)

    von Bogdandy, A.; Goldmann, M.; Venzke, I.

    This article argues that increasing demands in world public opinion for legitimate and effective international institutions require a paradigm shift in public international law. There is a part of public international law that should be better understood as international public law because it

  9. The main factors affecting somatic cell count in organic dairy farming

    Energy Technology Data Exchange (ETDEWEB)

    Orjales, I.; Lopez-Alonso, M.; Miranda, M.; Rodríguez-Bermúdez, R.; Rey-Crespo, F.; Villar, A.

    2017-07-01

    Preventive management practices are essential for maintaining acceptable udder health status, especially in organic farming, in which the use of antimicrobials is restricted. The contribution of the following factors to somatic cell count (SCC) was assessed in 788 cows from 15 organically reared herds in northern Spain: milk production, lactation number, treatments applied, selective dry cow therapy and teat dipping routines. The data were examined by linear logistic regression. Lactation number was the main factor affecting logSCC (β= 0.339, p<0.001) followed in order of importance by milk production (β= -0.205, p<0.001), use of alternative treatments (β=0.153, p<0.001), selective dry cow therapy (β=0.120, p=0.005) and teat dipping routines (β=-0.076, p=0.028). However, the model only explained 17.0% of the total variation in SCC. This variable depends on factors other than those considered here, amongst which udder infection is probably one of the most important. Nonetheless, the study findings enabled us to determine the contribution of the main management factors that should be taken into account to improve udder health status on organic farms.

  10. Case report of a pustular dermatitis outbreak in sheep: Clinical and food safety considerations

    Directory of Open Access Journals (Sweden)

    Mariana Roccaro

    2018-04-01

    Full Text Available The objective of this report is to describe an outbreak of pustular dermatitis in a flock of about 200 sheep, its clinical evolution and food safety implications. The onset of the symptoms was sudden and the lesions spread very quickly from ewe to ewe, so that in about 3 days almost all of the lactating sheep were stricken. Pustules from 5 different animals, six milk samples, two cheese samples, teat cup samples from the milking machine and farmer’s hands were analysed. A pure culture of Staphylococcus aureus, producing staphylococcal enterotoxin (SE C, was isolated from pustules. Milk and cheese showed a contamination by coagulase positive staphylococci <15 and 30 colony forming units respectively and the absence of SE. Farmer’s hands and teat cups samples resulted negative for coagulase positive staphylococci. Therapy with daily topical medicaments was prescribed and a prophylactic intervention was suggested by the administration of an autovaccine. The low level of milk and cheese contamination and the absence of SE in cheese supported the decision to not advise the farmer to recall cheese produced with milk from affected animals.

  11. A School-Based Dental Program Evaluation: Comparison to the Massachusetts Statewide Survey.

    Science.gov (United States)

    Culler, Corinna S; Kotelchuck, Milton; Declercq, Eugene; Kuhlthau, Karen; Jones, Kari; Yoder, Karen M

    2017-10-01

    School-based dental programs target high-risk communities and reduce barriers to obtaining dental services by delivering care to students in their schools. We describe the evaluation of a school-based dental program operating in Chelsea, a city north of Boston, with a low-income and largely minority population, by comparing participants' oral health to a Massachusetts oral health assessment. Standardized dental screenings were conducted for students in kindergarten, third, and sixth grades. Outcomes were compared in bivariate analysis, stratified by grade and income levels. A greater percentage of Chelsea students had untreated decay and severe treatment need than students statewide. Yet, fewer Chelsea third graders had severe treatment need, and more had dental sealants. There was no significant difference in the percentage of Chelsea students having severe treatment need or dental sealants by income level. Students participating in our program do not have lower decay levels than students statewide. However, they do have lower levels of severe treatment need, likely due to treatment referrals. Our results confirm that school-based prevention programs can lead to increased prevalence of dental sealants among high-risk populations. Results provide support for the establishment of full-service school-based programs in similar communities. © 2017, American School Health Association.

  12. Challenges imposed by International Environmental Law to Classical International Law

    Directory of Open Access Journals (Sweden)

    Fabian Augusto Cárdenas Castañeda

    2010-05-01

    Full Text Available The emergence of international environmental law has produced important challenges to the very foundations of public international law. Traditional concepts such as state sovereignty, subjects of international law, and the early perspectives of national security are being transformed. The needs of the contemporary international society differ from the ones of the Wesphalian conception, situations which clearly explains the raise of alternative views for the understanding of the current dynamics of international law, where concepts like res communis, common concerns and simply “commons” take a privileged place in the study of international law. The foregoing has been strengthened by the international development of the so called erga ommnes obligations, label which is being used by international environmental law as the perfect explanation of its own existence. This academic article presents and studies the abovementioned concepts trying to compare what international law used to be before the emergence of international environmental law and what it is and what it should be in order to attend the developments and challenges imposed by the contemporary international society, particularly by international environmental law, a new fi eld of the corpus juris of public international law.

  13. International Ecohealth Forum 2008 | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    ... the International Forum on Ecosystem Approaches to Human Health (Montreal, ... the International Association of Ecology and Health (IAEH), and a Brazilian ... Nutrition, health policy, and ethics in the age of public-private partnerships.

  14. Longleaf pine restoration in context comparisons of frequent fire forests

    Science.gov (United States)

    Seth Bigelow; Michael C. Stambaugh; Joseph J. O' Brien; Andrew J. Larson; Michael A. Battaglia

    2018-01-01

    To see a frequent-fire forest burn for the first time is to experience a remarkable teat of nature. Most people are accustomed to the slow change of forests with the seasons, not the instantaneous conversion of green and brown plant mass to smoke and char. Yet to visit such a forest a week after it bums is to see bright green shoots emerging, highlighted against a...

  15. Structural equation models to estimate risk of infection and tolerance to bovine mastitis.

    Science.gov (United States)

    Detilleux, Johann; Theron, Léonard; Duprez, Jean-Noël; Reding, Edouard; Humblet, Marie-France; Planchon, Viviane; Delfosse, Camille; Bertozzi, Carlo; Mainil, Jacques; Hanzen, Christian

    2013-03-06

    One method to improve durably animal welfare is to select, as reproducers, animals with the highest ability to resist or tolerate infection. To do so, it is necessary to distinguish direct and indirect mechanisms of resistance and tolerance because selection on these traits is believed to have different epidemiological and evolutionary consequences. We propose structural equation models with latent variables (1) to quantify the latent risk of infection and to identify, among the many potential mediators of infection, the few ones that influence it significantly and (2) to estimate direct and indirect levels of tolerance of animals infected naturally with pathogens. We applied the method to two surveys of bovine mastitis in the Walloon region of Belgium, in which we recorded herd management practices, mastitis frequency, and results of bacteriological analyses of milk samples. Structural equation models suggested that, among more than 35 surveyed herd characteristics, only nine (age, addition of urea in the rations, treatment of subclinical mastitis, presence of dirty liner, cows with hyperkeratotic teats, machine stripping, pre- and post-milking teat disinfection, and housing of milking cows in cubicles) were directly and significantly related to a latent measure of bovine mastitis, and that treatment of subclinical mastitis was involved in the pathway between post-milking teat disinfection and latent mastitis. These models also allowed the separation of direct and indirect effects of bacterial infection on milk productivity. Results suggested that infected cows were tolerant but not resistant to mastitis pathogens. We revealed the advantages of structural equation models, compared to classical models, for dissecting measurements of resistance and tolerance to infectious diseases, here bovine mastitis. Using our method, we identified nine major risk factors that were directly associated with an increased risk of mastitis and suggested that cows were tolerant but

  16. International opportunities and value creation in international entrepreneurship.

    NARCIS (Netherlands)

    Mainela, Tuija; Puhakka, Vesa; Wakkee, Ingrid; Marinova, Svetla; Larimo, Jorma; Nummela, Niina

    2016-01-01

    International entrepreneurship (IE) as a field of research has emerged at the intersection of internationalization and entrepreneurship theories. At this intersection it has come to emphasize the activities centered on international opportunities. International opportunities, then, are about value

  17. REFLECTIONS ON PRODUCTION INTERNALIZATION AND ITS INTERNATIONAL TRADE IMPLICATIONS

    Directory of Open Access Journals (Sweden)

    CLIPA RALUCA IRINA

    2014-06-01

    Full Text Available Vertically-integrated multinational companies place the different stages of production and marketing chain in different countries, looking for advantages such as low production costs, lower taxes, abundant resources and so on, while benefiting from the advantages of economies of scale, control of supplies or outlets. In fact, this vertical integration of multinational companies has led to the expansion of intra-firm trade and "internalized" operations, thus creating their own markets for the vertically-integrated production. Internationally active firms operate in a way that replaces the different functions of an open market with internal transactions, i.e. intra-firm transactions, whenever internal transaction costs are lower than the open-market ones. The direct consequence over international trade is the increase of intra-firm share of trade flows to one third of world trade, those companies making a suppression of international market segments that act in favour of an internal market. The creation of a multinational market and the enhancement of intra-firm trade have profound quantitative and qualitative implications on the composition, geographic orientation and dynamics of international trade. This paper deals with the issue of production internalization, with an overview of the main contributions made to the theory of internalization, while tackling its relative dimension. However, we intend to highlight the implications of this phenomenon on international trade. The work methodology falls within the range of qualitative approaches: logical argumentation, critical theoretical analysis.

  18. Quantifying Nanoparticle Internalization Using a High Throughput Internalization Assay.

    Science.gov (United States)

    Mann, Sarah K; Czuba, Ewa; Selby, Laura I; Such, Georgina K; Johnston, Angus P R

    2016-10-01

    The internalization of nanoparticles into cells is critical for effective nanoparticle mediated drug delivery. To investigate the kinetics and mechanism of internalization of nanoparticles into cells we have developed a DNA molecular sensor, termed the Specific Hybridization Internalization Probe - SHIP. Self-assembling polymeric 'pHlexi' nanoparticles were functionalized with a Fluorescent Internalization Probe (FIP) and the interactions with two different cell lines (3T3 and CEM cells) were studied. The kinetics of internalization were quantified and chemical inhibitors that inhibited energy dependent endocytosis (sodium azide), dynamin dependent endocytosis (Dyngo-4a) and macropinocytosis (5-(N-ethyl-N-isopropyl) amiloride (EIPA)) were used to study the mechanism of internalization. Nanoparticle internalization kinetics were significantly faster in 3T3 cells than CEM cells. We have shown that ~90% of the nanoparticles associated with 3T3 cells were internalized, compared to only 20% of the nanoparticles associated with CEM cells. Nanoparticle uptake was via a dynamin-dependent pathway, and the nanoparticles were trafficked to lysosomal compartments once internalized. SHIP is able to distinguish between nanoparticles that are associated on the outer cell membrane from nanoparticles that are internalized. This study demonstrates the assay can be used to probe the kinetics of nanoparticle internalization and the mechanisms by which the nanoparticles are taken up by cells. This information is fundamental for engineering more effective nanoparticle delivery systems. The SHIP assay is a simple and a high-throughput technique that could have wide application in therapeutic delivery research.

  19. International criminal justice: a pillar for the international rule of law

    Directory of Open Access Journals (Sweden)

    Gonzalo Aguilar Cavallo

    2012-12-01

    Full Text Available The international criminal justice has experienced a rapid change over the past years. This circumstance has underscored the need for interaction and complementation between international and domestic law. Some authors consider that the international criminal justice, and the activities of its tribunals, jeopardize the legality of international law. Our vision is that international criminal justice is a central pillar of the rule of law, at the national and the international levels. Far from undermining the legality of international law, international criminal justice paves the way towards a true international public order.

  20. Inhibition of Staphylococcus aureus invasion into bovine mammary epithelial cells by contact with live Lactobacillus casei.

    Science.gov (United States)

    Bouchard, Damien S; Rault, Lucie; Berkova, Nadia; Le Loir, Yves; Even, Sergine

    2013-02-01

    Staphylococcus aureus is a major pathogen that is responsible for mastitis in dairy herds. S. aureus mastitis is difficult to treat and prone to recurrence despite antibiotic treatment. The ability of S. aureus to invade bovine mammary epithelial cells (bMEC) is evoked to explain this chronicity. One sustainable alternative to treat or prevent mastitis is the use of lactic acid bacteria (LAB) as mammary probiotics. In this study, we tested the ability of Lactobacillus casei strains to prevent invasion of bMEC by two S. aureus bovine strains, RF122 and Newbould305, which reproducibly induce acute and moderate mastitis, respectively. L. casei strains affected adhesion and/or internalization of S. aureus in a strain-dependent manner. Interestingly, L. casei CIRM-BIA 667 reduced S. aureus Newbould305 and RF122 internalization by 60 to 80%, and this inhibition was confirmed for two other L. casei strains, including one isolated from bovine teat canal. The protective effect occurred without affecting bMEC morphology and viability. Once internalized, the fate of S. aureus was not affected by L. casei. It should be noted that L. casei was internalized at a low rate but survived in bMEC cells with a better efficiency than that of S. aureus RF122. Inhibition of S. aureus adhesion was maintained with heat-killed L. casei, whereas contact between live L. casei and S. aureus or bMEC was required to prevent S. aureus internalization. This first study of the antagonism of LAB toward S. aureus in a mammary context opens avenues for the development of novel control strategies against this major pathogen.

  1. Inhibition of Staphylococcus aureus Invasion into Bovine Mammary Epithelial Cells by Contact with Live Lactobacillus casei

    Science.gov (United States)

    Bouchard, Damien S.; Rault, Lucie; Berkova, Nadia; Le Loir, Yves

    2013-01-01

    Staphylococcus aureus is a major pathogen that is responsible for mastitis in dairy herds. S. aureus mastitis is difficult to treat and prone to recurrence despite antibiotic treatment. The ability of S. aureus to invade bovine mammary epithelial cells (bMEC) is evoked to explain this chronicity. One sustainable alternative to treat or prevent mastitis is the use of lactic acid bacteria (LAB) as mammary probiotics. In this study, we tested the ability of Lactobacillus casei strains to prevent invasion of bMEC by two S. aureus bovine strains, RF122 and Newbould305, which reproducibly induce acute and moderate mastitis, respectively. L. casei strains affected adhesion and/or internalization of S. aureus in a strain-dependent manner. Interestingly, L. casei CIRM-BIA 667 reduced S. aureus Newbould305 and RF122 internalization by 60 to 80%, and this inhibition was confirmed for two other L. casei strains, including one isolated from bovine teat canal. The protective effect occurred without affecting bMEC morphology and viability. Once internalized, the fate of S. aureus was not affected by L. casei. It should be noted that L. casei was internalized at a low rate but survived in bMEC cells with a better efficiency than that of S. aureus RF122. Inhibition of S. aureus adhesion was maintained with heat-killed L. casei, whereas contact between live L. casei and S. aureus or bMEC was required to prevent S. aureus internalization. This first study of the antagonism of LAB toward S. aureus in a mammary context opens avenues for the development of novel control strategies against this major pathogen. PMID:23183972

  2. 76 FR 63282 - Foreign-Trade Zone 140-Flint, Michigan; Application for Subzone; Dow Corning Corporation (Silicon...

    Science.gov (United States)

    2011-10-12

    ... Corning facility (1,250 employees, 489 acres, 450,000 metric tons capacity) is located at 3901 S. Saginaw... products including elastomers, resins, fluids, silanes, polymers, gums, sealants and emulsions. Components...

  3. Pengaruh Pemasaran Internal dan Kualitas Layanan Internal Terhadap Kepuasan Pelanggan Internal (Studi Pada Industri Kepariwisataan di Daerah Istimewa Yogyakarta

    Directory of Open Access Journals (Sweden)

    Jumadi Jumadi

    2016-06-01

    Full Text Available The aim of this research is to investigate the implication of internal marketing and internal service quality effectivity towards internal customer satisfaction in Tourism Industry in Yogyakarta Special Territory. This internal marketing studyinvolves variables of motivation and reward system, effective communication, effective employee's selection, effective recruitment, effective development, effective support system, and healthy work environment. While the internal quality service aspects that will be examined in this study are: tangible, emphaty, responsiveness, reliability and assurance, and then their influences on internal customer satisfaction would be analyzed.The sample size is 210 respondents,which is determined using purposive sampling method. The main instrument for data collection in this study is through questionnaire. The analysis tool used to examine the hypothesis of the study is Structural Equation Modeling using AMOS Version 20.0 Software. The result of the study shows that: Internal marketing and internal quality service significantly influence internal customers satisfation. However, the internal quality service influence the internal customers satisfaction more significantly. Therefore the managers in tourism industry should improve the internal marketing more than the internal quality service.

  4. Asphalt emulsion sealing of uranium mill tailings. 1980 annual report

    International Nuclear Information System (INIS)

    Hartley, J.N.; Koehmstedt, P.L; Esterl, D.J.; Freeman, H.D.; Buelt, J.L.; Nelson, D.A.; Elmore, M.R.

    1981-05-01

    Studies of asphalt emulsion sealants conducted by the Pacific Northwest Laboratory have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to near background levels. Field tests at the tailings pile in Grand Junction, Colorado, confirmed that an 8-cm admix seal containing 22 wt% asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and compacted, overburden was applied over the seal to protect the seal from ultraviolet degradation

  5. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  6. CHARACTERIZATION OF A NARROW SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY AGAINST UROPATHOGENIC BACTERIA

    Science.gov (United States)

    2017-08-28

    MA). First, diluted bovine serum albumin (BSA) standards were prepared following the manufacturer’s instructions. The BCA working reagent was...in Bovine Colostrum” J. Appl. Microbiol. 2009, 106, 233- 240. Blackburn, P., de la Harpe, J.; “Stabilized Lanthionine Bacteriocin Compositions” U. S...34 Sheila MF Torres, 2012, 323. Nickerson, Stephen C. "Choosing the Best Teat Dip for Mastitis Control and Milk Quality." NMC-Milk Quality Conf. Proceed

  7. International Relations

    OpenAIRE

    McGlinchey, S.

    2017-01-01

    A ‘Day 0’ introduction to International Relations for beginners. Written by a range of emerging and established experts, the chapters offer a broad sweep of the basic components of International Relations and the key contemporary issues that concern the discipline. The narrative arc forms a complete circle, taking readers from no knowledge to competency. The journey starts by examining how the international system was formed and ends by reflecting that International Relations is always adapti...

  8. International law

    CERN Document Server

    Shaw, Malcolm N

    2017-01-01

    International Law is the definitive and authoritative text on the subject, offering Shaw's unbeatable combination of clarity of expression and academic rigour and ensuring both understanding and critical analysis in an engaging and authoritative style. Encompassing the leading principles, practice and cases, and retaining and developing the detailed references which encourage and assist the reader in further study, this new edition motivates and challenges students and professionals while remaining accessible and engaging. Fully updated to reflect recent case law and treaty developments, this edition contains an expanded treatment of the relationship between international and domestic law, the principles of international humanitarian law, and international criminal law alongside additional material on international economic law.

  9. A new intermediate for the production of flexible stable polymers

    Science.gov (United States)

    Webster, J. A.

    1973-01-01

    Method of incorporating ether linkages into perfluoroalkylene segment of a dianydride intermediate yields intermediate that may be used in synthesis of flexible, stable polyimides for use as high-temperature, solvent-resistant sealants.

  10. 77 FR 31008 - Enforceable Consent Agreement Development for Two Cyclic Siloxanes; Solicitation of Interested...

    Science.gov (United States)

    2012-05-24

    ... No. 541-02-6) are high production volume chemicals having a wide variety of industrial, commercial..., soaps, detergents, adhesives, sealants, and rubber and plastic products. D4 is also used in processing...

  11. An evaluation of factors influencing feeding in babies with a cleft palate with and without a cleft lip.

    Science.gov (United States)

    Martin, Vanessa; Greatrex-White, Sheila

    2014-03-01

    The objective of this article was to determine the impact of different bottles and teats for feeding babies with a cleft palate (with and without a cleft lip) on weight velocity, feeding behaviour, and maternal self-esteem. A mixed methods study incorporating the use of diaries to record feeding patterns of babies and levels of professional support received was used. Growth was assessed by converting weights into standard deviation scores and using the differences to express weight velocity over a six-week period. Visual analogue scales were used to assess mothers' perceptions of their children and themselves. The Edinburgh Postnatal Depression Score (EPDS) was used to identify maternal depression. The study demonstrated that the most significant effect on weight was determined by cleft type. Babies with isolated clefts of the hard and soft palate experienced greater feeding problems and suffered the biggest weight losses. This remained significant independently of the type of bottle/teat used. Poor weight gain was also associated with a mother's low perception of herself and her child, and her tendency towards depression. The study highlights the importance of the early assessment of babies' feeding skills and regular follow-up and support from trained and experienced nurse specialists.

  12. Association between G316A growth hormone polymorphism and economic traits in pigs

    Directory of Open Access Journals (Sweden)

    Danielle Assis de Faria

    2006-01-01

    Full Text Available The association between G316A growth hormone polymorphism and quantitative traits was investigated in an F2 population of pigs. Association analyses were performed using a statistical model that included genotype, sex, batch and sex by genotype interaction as fixed effects and sire as random effect. The polymorphism was associated with the number of right teats (p = 0.03, heart weight (p = 0.04, lung weight (p = 0.05, carcass length determined by the Brazilian carcass classification method (p = 0.04, picnic shoulder weight (p = 0.07, jowl weight (p = 0.01, pH 24 h after slaughtering (p = 0.03 and drip loss (p = 0.01. Interaction between genotype and sex was observed for six performance traits. The additive effect was significant (p < 0.10 for heart weight, jowl weight and pH 24 h after slaughtering. The effect of dominance was significant (p < 0.05 for number of right teats, heart weight, carcass length, picnic shoulder weight and pH 24 h after slaughtering. This study shows that the growth hormone gene is a potential candidate for investigating the phenotypic variation of quantitative traits in pigs, and suggests its possible application in breeding programs.

  13. Prevalence of Subclinical Mastitis and Distribution of Pathogens in Dairy Farms of Rubavu and Nyabihu Districts, Rwanda

    Directory of Open Access Journals (Sweden)

    J. P. Mpatswenumugabo

    2017-01-01

    Full Text Available A cross-sectional study was conducted from May 2016 to January 2017 in Rubavu and Nyabihu districts, Western Rwanda, aiming at estimating the prevalence of subclinical mastitis (SCM and identifying its causative bacteria. Management practices and milking procedures were recorded through a questionnaire. 123 crossbreed milking cows from 13 dairy farms were randomly selected and screened for SCM using California Mastitis Test (CMT. Composite CMT positive milk samples were processed for bacterial isolation and identification. The overall SCM prevalence at cow level was 50.4%. 68 bacterial isolates were identified by morphological and biochemical characteristics. They included, Coagulase Negative Staphylococci (51.5%, Staphylococcus aureus (20.6%, Streptococcus species (10.3%, Bacillus species (10.3%, Streptococcus agalactiae (5.8%, and Escherichia coli (1.5%. About 67.1% of the farmers checked for mastitis; of these, 58.9% relied on clinical signs and only 6.8% screened with CMT. Only 5.5% and 2.7% of the farmers tried to control mastitis using dry cow therapy and teat dips, respectively. Thus, to reduce the prevalence of SCM, farmers in the study area need to be trained on good milking practices, including regular use of teat dips, application of dry cow therapy, and SCM screening. This will improve their sales and their financial status.

  14. International Specialization

    DEFF Research Database (Denmark)

    Kleindienst, Ingo; Geisler Asmussen, Christian; Hutzschenreuter, Thomas

    2012-01-01

    Whether and how international diversification and cross-border arbitrage affects firm performance remains one of the major unresolved research questions in the strategy and international business literatures. We propose that knowing how much a firm has internationally diversified tells us very...... little about performance implications, if we do not know, and do not ask, how the firm has diversified. Therefore, building on the two broad arguments of operating flexibility and location-specific commitment, we develop a theoretical framework that focuses on the extent to which a firm's international...... arbitrage strategy is characterized by specialization versus replication and argue that these different strategies may have differential impact on profitability and risk reduction. Developing a sophisticated measure of international specialization and using a unique panel data set of 92 German MNEs to test...

  15. Alternative international currencies

    Directory of Open Access Journals (Sweden)

    Rozhentsova Vladimirovna Elena

    2012-01-01

    Full Text Available The modern international monetary system has a number of flaws and therefore needs cardinal change. Hence, economists from all over the world are suggesting alternative international currencies that would make the international monetary system more efficient. However, it is essential when approaching the creation of a new international currency to analyze and take into account the experience of all the past international currencies. Therefore this paper begins with an exploration of the drawbacks of each of the past and present international currencies. Drawing on this analysis a justification will be made for the necessity of introducing a new international currency, pointing to the requirements it should meet. Further on, this paper proposes an alternative theoretically possible variant of the international currency, with a fixed value relative to a commodity basket. An abstract example is used to demonstrate its composition and circulation mechanism.

  16. Oral Health Disparities as Determined by Selected Healthy People 2020 Oral Health Objectives for the United States, ...

    Science.gov (United States)

    ... dental caries varied by race and ethnicity and poverty level among children and adolescents. Figure 1. Prevalence ... income groups. Prevalence of dental sealants varied by poverty status among children, and varied by race and ...

  17. Pengaruh Pemasaran Internal dan Kualitas Layanan Internal Terhadap Kepuasan Pelanggan Internal (Studi Pada Industri Kepariwisataan di Daerah Istimewa Yogyakarta)

    OpenAIRE

    Jumadi Jumadi

    2016-01-01

    The aim of this research is to investigate the implication of internal marketing and internal service quality effectivity towards internal customer satisfaction in Tourism Industry in Yogyakarta Special Territory. This internal marketing studyinvolves variables of motivation and reward system, effective communication, effective employee's selection, effective recruitment, effective development, effective support system, and healthy work environment. While the internal quality service aspects ...

  18. The International Criminal Court and the construction of International Public Order

    Directory of Open Access Journals (Sweden)

    Sofia Santos

    2014-11-01

    Full Text Available Envisioning an international public order means envisioning an order sustained by a legal and institutional framework that ensures effective collective action with a view to defending fundamental values of the international community and to solving common global problems, in line with the universalist vision of international law. Envisioning the construction of an international public order means considering that this framework, which embraces and promotes the respect for human rights focused particularly on human dignity, is consolidating and evolving based on the International Criminal Court (ICC. The establishment of the ICC added an international punitive perennial facet to international humanitarian law and international human rights law and linked justice to peace, to security and to the well-being of the world, reaffirming the principles and objectives of the Charter of the United Nations (UN. Nevertheless, the affirmation process of an international criminal justice by punishing those responsible for the most serious crimes of concern to the international community as a whole, faces numerous obstacles of political and normative character. This article identifies the central merits of the Rome Statute and ICC’s practice and indicates its limitations caused by underlying legal-political tensions and interpretive questions relating to the crime of aggression and crimes against humanity. Finally, the article argues for the indispensability of rethinking the jurisdiction of the ICC, defending the categorization of terrorism as an international crime, and of articulating its mission with the "responsibility to protect", which may contribute to the consolidation of the ICC and of international criminal law and reinforce its role in the construction of an effective international public order.

  19. Relationship between the international marketing research and the international marketing information system

    OpenAIRE

    Grubor Aleksandar

    2004-01-01

    Real and complete understanding relationship between the international marketing research and the international marketing information system requires recognizing essentials of the both concept. The international marketing research constitutes a process with coherent phases, whereas the international marketing information system is a part of integrated company's information system. Approach to learning relationship between the international marketing research and the international marketing in...

  20. Kroonipalaviku põhjustajad tegelevad valuutaäriga / Andrus Karnau, Aleksei Günter

    Index Scriptorium Estoniae

    Karnau, Andrus

    2007-01-01

    Ilmunud ka: Postimees : na russkom jazõke, 28. nov. 2007, lk. 2. Firmade Ärif OÜ ja Baltoc Forex OÜ ärimeeste Jevgeni Kanteri, Aleksander Tshebõkini ja Kirill Shevtshenko seotusest venekeelse ärifoorumiga, mis riputas üles teate krooni devalveerimise kohta selleks, et õppida käitumist kriisiolukorras. Öise Vahtkonna rollist rahavahetuse põhjustamisel. Vt. samas: Hindrek Riikoja. Paanika tõi rahavahetustesse üle 30 miljoni krooni. Kommenteerivad Mart Sõrg, Veiko Maripuu

  1. Ilves kohtub juunikuus Bushiga / Raimo Poom

    Index Scriptorium Estoniae

    Poom, Raimo

    2007-01-01

    Valgest Majast tulnud teate kohaselt toimub Eesti presidendi Toomas Hendrik Ilvese ja USA presidendi George W. Bushi kohtumine 25. juunil 2007 Washingtonis. President T.H. Ilvese visiidist teavitamise ajastus on tugev signaal USA toetusest Eestile. Vahetult enne presidentide kohtumise avalikustamist kiitis USA senat heaks Eestit toetava resolutsiooni. USA välisministri Condoleezza Rice'i, USA kongresmeni John Shimkuse ja USA abivälisministri Daniel Friedi arvamusi. Lisa: USA senat: Eestil on õigus

  2. Extended antibiotic treatment of persistent bovine mastitis during lactation : Efficacy, economics and social influences

    OpenAIRE

    Swinkels, J.M.

    2014-01-01

    Mastitis is an inflammation of the udder caused by bacteria that invade the udder through the teat canal, causing either persistent intramammary infections, or short, transient infections. Mastitis is the most costly disease on a dairy farm because it directly affects the production of milk, the primary source of income for the dairy farmer. Mastitis can be visible (clinical mastitis) or invisible (subclinical mastitis). A large proportion of farmers repeats antibiotic treatment after initial...

  3. THE PROBLEMS AND PROSPECTS OF THE USE OF ELASTOMER SEALS FOR SEALING OF UNDERGROUND STRUCTURES

    Directory of Open Access Journals (Sweden)

    L. H. Politikova

    2007-10-01

    Full Text Available The research work on creation of effective rubber sealants for hermetic sealing of joints of underground structures from modular ferro-concrete and pig-iron including the underground tunnel casings is carried out.

  4. Director, Risk Management and Internal Audit | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Directs the establishment of an IDRC strategy for Internal Audit that outlines the ... process and are developed with an understanding of IDRC context and business model; ... Planning, Conduct and Reporting of Internal Audit Engagements:.

  5. International Responsibility and the Systemic Character of International Law

    Directory of Open Access Journals (Sweden)

    Saganek Przemysław

    2017-12-01

    Full Text Available The question whether international law is a system is one of the modern topics discussed by specialists of international law. The text of P. Saganek poses this question with respect to the rules on international responsibility. The two aims are to establish whether the rules on state responsibility are a system themselves and whether they may prima facie support the idea of international law as such a system. The two prima facie answers are positive. Every violation of international law gives rise to state responsibility if it can be attributed to a state and no circumstance precluding wrongfulness is in place. In this sense the rules on state responsibility form a sub-system supporting the thesis on the systemic nature of international law. On a closer analysis one can encounter several doubts as to both answers. Paradoxically those rules are too ideal, too systemic. The author – without denying the necessity of several if not the majority of the identified rules – refers to a tendency of presenting as law some non-binding documents prepared by expert groups. This is a part of a wider process of ‘paper-law’. In this sense expert groups engage in ‘creating the language’ in which the true subjects of international law are expected to speak.

  6. Windows® Internals

    CERN Document Server

    Russinovich, Mark E; Ionescu, Alex

    2009-01-01

    See how the core components of the Windows operating system work behind the scenes-guided by a team of internationally renowned internals experts. Fully updated for Windows Server 2008 and Windows Vista, this classic guide delivers key architectural insights on system design, debugging, performance, and support-along with hands-on experiments to experience Windows internal behavior firsthand.Delve inside Windows architecture and internals:Understand how the core system and management mechanisms work-from the object manager to services to the registryExplore internal system data structures usin

  7. Relationship between the international marketing research and the international marketing information system

    Directory of Open Access Journals (Sweden)

    Grubor Aleksandar

    2004-01-01

    Full Text Available Real and complete understanding relationship between the international marketing research and the international marketing information system requires recognizing essentials of the both concept. The international marketing research constitutes a process with coherent phases, whereas the international marketing information system is a part of integrated company's information system. Approach to learning relationship between the international marketing research and the international marketing information system is distinguish in domestic than in the foreign expert literature.

  8. Leedu lükkas tagasi teate suundumisest piraadijahile / Evelyn Kaldoja

    Index Scriptorium Estoniae

    Kaldoja, Evelyn, 1980-

    2008-01-01

    Leedulaste seas põhjustas hämmingut Euroopa Liidu eesistuja Prantsusmaa kaitseministri Herve Morini teade, et ka Leedu merevägi tahab osaleda piraatlusevastasel operatsioonil Somaalia rannikul. Vt. samas: Kaaperdatud laev

  9. Udder Morphological Traits and Milk Yield of Chilota and Suffolk Down Sheep Breeds Morfología Mamaria y Producción Lechera de las Razas Ovinas Chilota y Suffolk Down

    Directory of Open Access Journals (Sweden)

    María E Martínez

    2011-03-01

    Full Text Available Morphological traits of the whole udder (circumference, width, height, and length, teats (angle, length and width, udder cistern (teat opening and cistern height, and milk yield were measured over one lactation in a total of 18 ewes (nine Chilota and nine Suffolk Down sheep belonging to the same experimental flock (Centro Experimental INIA Butalcura, Chiloé, Chile. Analysis of variance showed significant effects for breed, sheep within breed, and stage of lactation. Chilota ewes evidenced greater udder circumference (433 mm, udder length (86 mm, teat opening (96º, and milk yield (947 mL d-1 than Suffolk Down ewes (410 mm, 77 mm, 93º, and 559 mL d-1, respectively. Udder circumference, udder width, udder length, cistern height and teat size significantly decreased throughout lactation. Repeatabilities of all traits were between 0.17 and 0.60; the highest repeatability was for udder circumference. This trait is easy to measure and had a discriminatory value for breed differentiation. In conclusion, Chilota sheep had a dairy aptitude greater than Suffolk Down sheep and similar to Spanish and Mediterranean dairy sheep breeds at beginning of their breeding programs.Los caracteres morfológicos de la ubre (perímetro, anchura, longitud y altura, de los pezones (ángulo de inclinación, longitud y anchura, de las cisternas mamarias (apertura de los pezones y altura de la cisterna y la producción lechera fueron medidos a lo largo de una lactación en un total de 18 ovejas del mismo rebaño (Centro Experimental INIA Butalcura, Chiloé, Chile, nueve de raza Chilota y nueve de raza Suffolk Down. El análisis de varianza mostró efectos significativos de la raza, la oveja dentro de la raza y del estado de lactación sobre las variables estudiadas. La raza Chilota evidenció un mayor perímetro de la ubre (433 mm, longitud de la ubre (86 mm, abertura de los pezones (96º, y producción lechera (947 mL d-1 que la Suffolk Down ( 410 mm, 77 mm, 93º, y 559 m

  10. The International School Industry: Examining International Schools through an Economic Lens

    Science.gov (United States)

    MacDonald, James

    2006-01-01

    Based upon the results of a quantitative analysis of tuition revenues generated by international schools, it is argued that international schools can be examined in terms of a global multi-billion dollar industry and that business theory can be, and is being, applied in international schools today. This article proposes that international schools…

  11. Juris International

    CERN Document Server

    A database on international trade law aimed at lawyers and legal counsel in developing and transition economies. Juris International is a multilingual collection (English, Spanish, and French) of legal information on international trade. Juris International aims to facilitate and reduce the work involved in research for business lawyers, advisers and in-house counsel, and state organizations in developing nd transition economies, by providing access to texts which have often been difficult to obtain. Its objective is to gather a large quantity of basic information at one site (favoring complete legal texts), without the need to send for the information, and consequently without excessive communication costs for users who d benefit from an efficient and cheap telecommunications network.

  12. Importance of Internal Audit and Internal Control in an organization - Case Study

    OpenAIRE

    Bubilek, Olga

    2017-01-01

    This research is a descriptive case study of a company. It presents concepts of the internal audit and internal control based on an example of a Finnish company. The research examines the role and importance that internal audit and internal controls have in an organization. The main research question is “What is the role and importance of internal audit and internal control in an organization” Additional sub-questions relating to the case company that will allow for better understanding of...

  13. 77 FR 69824 - Certain New Chemicals; Receipt and Status Information

    Science.gov (United States)

    2012-11-21

    ...) Crosslinker in (G) Acetonoximino moisture cure sealant silane. formulaion. P-13-0020 10/11/2012 1/8/2013 Zeon... isomers of condensation products of substituted diazotized aminoanilines. P-12-0156 10/4/2012 9/21/2012 (G...

  14. Traditional preventive treatment options

    DEFF Research Database (Denmark)

    Longbottom, C; Ekstrand, K; Zero, D

    2009-01-01

    Preventive treatment options can be divided into primary, secondary and tertiary prevention techniques, which can involve patient- or professionally applied methods. These include: oral hygiene (instruction), pit and fissure sealants ('temporary' or 'permanent'), fluoride applications (patient...... options....

  15. 77 FR 61308 - Outer Continental Shelf Air Regulations; Consistency Update for California

    Science.gov (United States)

    2012-10-09

    ... Specific Source Standards (Adopted 07/06/76) Rule 74.1 Abrasive Blasting (Adopted 11/12/91) Rule 74.2... Oil Field Drilling Operations (Adopted 01/08/91) Rule 74.20 Adhesives and Sealants (Adopted 01/11/05...

  16. International health law : an emerging field of public international law

    NARCIS (Netherlands)

    Toebes, Brigit

    This article discusses the nature and scope of international health law as an emerging field of public international law. It is argued that the protection of health reflects a pressing social need that should now be spoken of in the vocabulary of international law. Furthermore, there is an urgent

  17. Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.

    OpenAIRE

    Benedict, R; Amato, Mp; Boringa, J; Brochet, B; Foley, F; Fredrikson, S; Hamalainen, P; Hartung, H; Krupp, L; Penner, I; Reder, A; Langdon, D.

    2012-01-01

    An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different langu...

  18. Models of international entrepreneurship

    DEFF Research Database (Denmark)

    Rask, Morten; Servais, Per

    2012-01-01

    on International Entrepreneurship, and specifically but not exclusively, International New Ventures (INVs). The three resulting ‘meta-models’ depict the activities and loci of such firms (Figure 1), the motivating factors that give rise to such firms (Figure 2) and their growth modalities and strategies (Figure 3......). These models reflect the merger of entrepreneurship and international business into the field of international entrepreneurship. Managers in international entrepreneurial firms and students in international business and entrepreneurship can use the models as framework for understanding international...... entrepreneurship....

  19. The ICC, International Criminal Justice and International Politics

    African Journals Online (AJOL)

    short, does it have a future, and how shall it remain relevant in the future? This article is a think piece ... Introduction. The International Criminal ... in its operations by international politics, are the ICC's weaknesses a function of its very nature or ...

  20. Tactile stimulation of dairy heifers: effects on behavior and milk production after calving

    Directory of Open Access Journals (Sweden)

    N. R. M. Néri

    2016-09-01

    Full Text Available The positive management of primiparous heifers before calving through tactile stimulation may have beneficial effects on behavior during routine milking. The objective of this study was to evaluate the use of tactile stimulation in dairy heifers and its effects on behavior and milk production after calving. Ten primiparous Holstein heifers were used. Half the group received training with tactile stimulation of all body regions, while the other group did not receive stimulation (control group. The training period was divided into three phases: early, days 1 to 6 of training; intermediate: days 7 to 12, and final, days 13 to 23. During training, movement and displacement scores were obtained over a period of 5 minutes. Physiological parameters were also recorded [respiratory rate (FR and minimum eye temperature (ETmin measured with a thermal imaging camera]. After calving, the heifers were submitted to first milking when the evaluations were started for the first 10 days of milking (20 consecutive milkings. The behavior of the animals was evaluated by attributing a reactivity score of 1 (desirable behaviors or 2 (undesirable behaviors: entry into the pen, teat disinfection, milking one or two jets of milk for mastitis testing, attachment of teat cups, and removal of milk, as well as the amount of milk produced. Mean ETmin and FR decreased over the training period. A significant difference was observed for displacement score (P=0.019, with a reduction in displacement from the early to the final period (from 60.0% to 25.7%. During the attachment of teat cups, stimulated heifers were less reactive (P=0.002, characterized by a lower frequency of undesirable behaviors (12.0%, than unstimulated heifers (30.2%. The average milk yield during the first 60 days of lactation was higher for the group of stimulated heifers (Ln y=2.20–0.0102t+0.331lnt, R2=0.76 compared to unstimulated heifers (Ln y=1.54–0.0191x+0.578lnx, R2=0.79, with this difference being