WorldWideScience

Sample records for internal lobed mixers

  1. Cross-Stream PIV Measurements of Jets With Internal Lobed Mixers

    Science.gov (United States)

    Bridges, James; Wernet, Mark P.

    2004-01-01

    With emphasis being placed on enhanced mixing of jet plumes for noise reduction and on predictions of jet noise based upon turbulent kinetic energy, unsteady measurements of jet plumes are a very important part of jet noise studies. Given that hot flows are of most practical interest, optical techniques such as Particle Image Velocimetry (PIV) are applicable. When the flow has strong azimuthal features, such as those generated by chevrons or lobed mixers, traditional PIV, which aligns the measurement plane parallel to the dominant flow direction is very inefficient, requiring many planes of data to be acquired and stacked up to produce the desired flow cross-sections. This paper presents PIV data acquired in a plane normal to the jet axis, directly measuring the cross-stream gradients and features of an internally mixed nozzle operating at aircraft engine flow conditions. These nozzle systems included variations in lobed mixer penetration, lobe count, lobe scalloping, and nozzle length. Several cases validating the accuracy of the PIV data are examined along with examples of its use in answering questions about the jet noise generation processes in these nozzles. Of most interest is the relationship of low frequency aft-directed noise with turbulence kinetic energy and mean velocity.

  2. Turbulent measurements in the lobe mixer of a turbofan engine. Turbofan engine lobe mixer nagare no ranryu keisoku

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Makoto; Ogawa, Yuji; Arakawa, Chuichi; Tagori, Tetsuo [Ishikawajima-Harima Heavy Industries, Co., Ltd., Tokyo, (Japan) Nippon Steel Corp., Tokyo, (Japan) The Univ. of Tokyo, Tokyo, (Japan). Faculty of Engineering The Univ. of Tsukuba, Tsukuba, (Japan)

    1990-01-25

    In order to examine the flow generated by the lobe mixer of a turbofan engine precisely, after measuring a three dimensional turbulent flow by a hot-wire anemometer, the mixing process of a bypass flow and a core flow with cross-sectional vortexes, and factors generating the vortex were clarified experimentally using the scale model of an exhaust duct with the lobe mixer. As a result, the mixing process was strongly affected by a lobe tip figure and a lobe figure near a center-body, and affected by the minimum gap between the lobe and center-body. The subsequent mixing process was scarcely affected by the ratio of a core flow velocity to a bypass flow one, although strongly affected by flow conditions on a lobe surface. Since the lobe mixer promoted the mixing around a center axis shifting a fast core flow outwards, it was unfavorable to mixing, however, it was expected to be useful for reducing engine jet noise. 3 refs., 7 figs.

  3. Calculation of lobe mixer flow with reynolds stress model. Oryoku hoteishiki model ni yoru lobe mixer ryu no suchi keisan

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Makoto; Arakawa, Chuichi; Tagori, Tetsuo [Ishikawajima-Harima Heavy Industries, Co., Ltd., Tokyo (Japan) Univ. of Tokyo, Tokyo (Japan). Faculty of Engineering Univ. of Tsukuba, Tsukuba (Japan)

    1990-02-25

    It is considered that exhaust gas energy of turbofan engine is partly collected to realize the improvement of propulsion efficiency together with the reduction of noise appeared by the change in velocity distribution of exhaust gas flow. Then Lobe mixer was studied and its effectiveness was widely recognized, however the development of more realistic prediction method of exhaust nozzle system including Lobe mixer, is not completed yet. The stress equation model with low Reynolds Number which is easily used by the expansion of Launder Reece Rodi model in three dimension coordinate system was newly constructed. Applicability of the stress equation in more complicated flow field was greatly improved. While the above model was applied to Lobe mixer system, then the qualitative reproduction of mixing process accompanied with flow around Lobe and longitudinal eddy of core or bi-pass flow, was realized. There is room for improvement of pressure strain correlation term and behavior of Reynolds stress very close by wall surface in this model. 16 refs., 9 figs., 1 tab.

  4. Turbofan forced mixer lobe flow modeling. 1: Experimental and analytical assessment

    Science.gov (United States)

    Barber, T.; Paterson, R. W.; Skebe, S. A.

    1988-01-01

    A joint analytical and experimental investigation of three-dimensional flowfield development within the lobe region of turbofan forced mixer nozzles is described. The objective was to develop a method for predicting the lobe exit flowfield. In the analytical approach, a linearized inviscid aerodynamical theory was used for representing the axial and secondary flows within the three-dimensional convoluted mixer lobes and three-dimensional boundary layer analysis was applied thereafter to account for viscous effects. The experimental phase of the program employed three planar mixer lobe models having different waveform shapes and lobe heights for which detailed measurements were made of the three-dimensional velocity field and total pressure field at the lobe exit plane. Velocity data was obtained using Laser Doppler Velocimetry (LDV) and total pressure probing and hot wire anemometry were employed to define exit plane total pressure and boundary layer development. Comparison of data and analysis was performed to assess analytical model prediction accuracy. As a result of this study a planar mixed geometry analysis was developed. A principal conclusion is that the global mixer lobe flowfield is inviscid and can be predicted from an inviscid analysis and Kutta condition.

  5. Hydrodynamic studies in a mixer of mixer settler system

    International Nuclear Information System (INIS)

    Shenoy, K.T.; Ghosh, S.K.; Keni, V.S.

    1994-01-01

    Pump-mix mixer settlers, with high throughput, are widely used in hydrometallurgical processing for recovery of uranium, copper etc. by solvent extraction. Detailed knowledge of hydrometallurgic behaviour in the mixer and settler is necessary for design. The paper presents the experimental study carried out on mixer hydrodynamics. The work was carried out on 40 litre, cubical, continuous flow mixer with bottom inlet and top discharge. The impeller was top shrouded turbine and working medium was water. Parameters such as impeller diameter, impeller clearance, inlet orifice size, impeller speed and flow rate were studied for effect on pumping head developed and power consumed by the mixer. Data are presented in the terms of dimensionless groups. Importance of the design variables is discussed. (author)

  6. Development of maleated starches using an internal mixer

    International Nuclear Information System (INIS)

    Dias, Fernanda T.G.; Andrade, Cristina T.

    2009-01-01

    Novel maleated starches (MSt) were prepared by chemical modification of cornstarch with maleic anhydride (MA), using an internal mixer as a reactor. Benzoyl peroxide (BPO) was chosen as initiator. Physico-chemical parameters were determined for the process carried out at different MA contents, under the same reaction conditions. Processing was carried out at 50 deg C, 30 rpm for 8 min.Torque developed during processing was given by the digital display of the rheometer, and the total specific mechanical energy (SME) input was estimated. FTIR measurements confirmed the successful incorporation of MA into the starch backbone. In addition, WAXS diffraction analyses revealed disruption of the crystalline structure of native starch for the products. Such reactions promoted by MA reduced the crystallinity of the products. The results indicated that the MA content had a significant effect on the characteristics of the processed starch samples. (author)

  7. Hydrodynamic studies in a mixer of mixer settler system

    Energy Technology Data Exchange (ETDEWEB)

    Shenoy, K T; Ghosh, S K; Keni, V S [Chemical Engineering Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    Pump-mix mixer settlers, with high throughput, are widely used in hydrometallurgical processing for recovery of uranium, copper etc. by solvent extraction. Detailed knowledge of hydrometallurgic behaviour in the mixer and settler is necessary for design. The paper presents the experimental study carried out on mixer hydrodynamics. The work was carried out on 40 litre, cubical, continuous flow mixer with bottom inlet and top discharge. The impeller was top shrouded turbine and working medium was water. Parameters such as impeller diameter, impeller clearance, inlet orifice size, impeller speed and flow rate were studied for effect on pumping head developed and power consumed by the mixer. Data are presented in the terms of dimensionless groups. Importance of the design variables is discussed. (author). 2 refs., 7 figs., 2 tabs.

  8. Terahertz radiation mixer

    Science.gov (United States)

    Wanke, Michael C [Albuquerque, NM; Allen, S James [Santa Barbara, CA; Lee, Mark [Albuquerque, NM

    2008-05-20

    A terahertz radiation mixer comprises a heterodyned field-effect transistor (FET) having a high electron mobility heterostructure that provides a gatable two-dimensional electron gas in the channel region of the FET. The mixer can operate in either a broadband pinch-off mode or a narrowband resonant plasmon mode by changing a grating gate bias of the FET. The mixer can beat an RF signal frequency against a local oscillator frequency to generate an intermediate frequency difference signal in the microwave region. The mixer can have a low local oscillator power requirement and a large intermediate frequency bandwidth. The terahertz radiation mixer is particularly useful for terahertz applications requiring high resolution.

  9. Transitory powder flow dynamics during emptying of a continuous mixer

    OpenAIRE

    Ammarcha , Chawki; Gatumel , Cendrine; Dirion , Jean-Louis; Cabassud , Michel; Mizonov , Vadim; Berthiaux , Henri

    2013-01-01

    International audience; This article investigates the emptying process of a continuous powder mixer, from both experimental and modelling points of view. The apparatus used in this work is a pilot scale commercial mixer Gericke GCM500, for which a specific experimental protocol has been developed to determine the hold up in the mixer and the real outflow. We demonstrate that the dynamics of the process is governed by the rotational speed of the stirrer, as it fixes characteristic values of th...

  10. Flashback resistant pre-mixer assembly

    Science.gov (United States)

    Laster, Walter R [Oviedo, FL; Gambacorta, Domenico [Oviedo, FL

    2012-02-14

    A pre-mixer assembly associated with a fuel supply system for mixing of air and fuel upstream from a main combustion zone in a gas turbine engine. The pre-mixer assembly includes a swirler assembly disposed about a fuel injector of the fuel supply system and a pre-mixer transition member. The swirler assembly includes a forward end defining an air inlet and an opposed aft end. The pre-mixer transition member has a forward end affixed to the aft end of the swirler assembly and an opposed aft end defining an outlet of the pre-mixer assembly. The aft end of the pre-mixer transition member is spaced from a base plate such that a gap is formed between the aft end of the pre-mixer transition member and the base plate for permitting a flow of purge air therethrough to increase a velocity of the air/fuel mixture exiting the pre-mixer assembly.

  11. 26 CFR 48.4061-1 - Temporary regulations with respect to floor stock refunds or credits on cement mixers.

    Science.gov (United States)

    2010-04-01

    ... stock refunds or credits on cement mixers. 48.4061-1 Section 48.4061-1 Internal Revenue INTERNAL REVENUE... § 48.4061-1 Temporary regulations with respect to floor stock refunds or credits on cement mixers. (a... of tax on motor vehicles) on the sale of a cement mixer after June 30, 1968, and before January 1...

  12. Microwave mixer technology and applications

    CERN Document Server

    Henderson, Bert

    2013-01-01

    Although microwave mixers play a critical role in wireless communication and other microwave applications employing frequency conversion circuits, engineers find that most books on this subject emphasize theoretical aspects, rather than practical applications. That's about to change with the forthcoming release of Microwave Mixer Technology and Applications. Based on a review of over one thousand patents on mixers and frequency conversion, authors Bert Henderson and Edmar Camargo have written a comprehensive book for mixer designers who want solid ideas for solving their own design challenges.

  13. Study of a new static mixer for two-phase and single-phase flows

    International Nuclear Information System (INIS)

    Foucrier, Michel

    1996-01-01

    The subject of this work is the study of OptimiX, a new static mixer, which is fully designed using an inverse method taking the final product features as input and based on the physical properties of the fluid to mix. The work began with the construction of an experimental loop which allowed us to qualify the mixer in two-phase and single-phase flow conditions. Next, a chemical method using a new test reaction and a micro-mixing model have been used to further characterise the mixer. This test reaction and the micro-mixing model have been developed by the 'Laboratoire des Sciences du Genie Chimique' of Nancy. The mixer OptimiX has proved to be an excellent device for both macro- and micro-mixing. The capability of this mixer to foster rapid reactions was also demonstrated. The well organised flow pattern of OptimiX, which results from its design, provides it with the unusual feature of being fully calculable. This work emphasizes the internal hydrodynamics of this mixer, justifies the universality of the design procedures, which validation is supported by the completed qualification work. (author) [fr

  14. MM wave quasioptical SIS mixers

    International Nuclear Information System (INIS)

    Hu, Qing; Mears, C.A.; Richards, P.L.; Lloyd, F.L.

    1988-08-01

    We have tested the performance of planar SIS mixers with log-periodic antennas at near millimeter and submillimeter wave frequencies from 90 to 360 GHz. The large ωR/sub N/C product (/approximately/10 at 90 GHz) of our Nb/NbO/sub x//Pb-In-Au junctions requires an integrated inductive tuning element to resonate the junction capacitance at the operating frequencies. We have used two types of integrated tuning element, which were designed with the aid of measurements using a Fourier transform spectrometer. Preliminary results indicate that the tuning elements can give very good mixer performance up to at least 200 GHz. An inductive wire in parallel with a 5-junction array gives a minimum mixer noise temperature of 115K (DSB) at 90 GHz with a FWHM bandwidth of 8 GHz. An open-ended microstrip stub in parallel with a single junction, gives minimum mixer noise temperatures of 150 and 200K (DSB) near 90 and 180 GHz with FWHM bandwidths of 4 and 3 GHz, respectively. The relatively high mixer noise temperatures compared to those of waveguide SIS mixers in a similar frequency range are attributed mainly to the losses in our optical system, which is being improved. 13 refs., 6 figs., 1 tab

  15. Scale-up of the mixer of a mixer-settler model used in a uranium solvent extraction process

    International Nuclear Information System (INIS)

    Santana, A.O. de; Dantas, C.C.

    1995-01-01

    Scale-up relations were obtained for the mixer of a box type mixer-settler used in an uranium extraction process from chloridric leaches. Three box type mixers of different sizes and with the same geometry were used for batch and continuous-flow experiments. The correlations between the extraction rate and he specific power input, D/T ratio(=turbine diameter/mixer width) and residence time were experimentally determined. The results showed that the extraction rate increases with the power input at a constant D/T ratio equal to 1/3, remaining however, independent from the mixer size for a specific value of the power input. This behaviour was observed for power input values ranging from 100 to 750 W/m 3 . (author) 8 refs.; 8 figs.; 4 tabs

  16. Effect of operational parameters and internal recycle on rhenium solvent extraction from leach liquors using a mixer-settler

    Directory of Open Access Journals (Sweden)

    Mostafa Hosseinzadeh

    2014-06-01

    Full Text Available The extraction of rhenium from molybdenite roasting dust leach solution was performed using a mixer-settler extractor by tributyl phosphate (TBP diluted in kerosene as the extractant. In the single-stage extraction experiments, effect of the aqueous to organic phase ratios, Qa/Qo, and the number of extraction stages, N, on the rhenium extraction was studied. It was found that using the phase ratio of 1:1 in a two-stage extraction, 87.5% depletion of rhenium was obtained. The comparison of experimental results with the continuous co-current extraction showed a good agreement. The effect of internal recycle of organic phase was investigated in the phase ratio of 1:1 by changing the flow rate ratio of recycle-to-fresh organic phase, Qro/Qfo. The optimum performance was achieved in the phase ratio, Qro/Qfo, equal to 3:7. It was found that improvement in the performance of the mixer-settler for the rhenium-TBP system can be obtained in the phase ratio of 1:1when Qro/Qfo = 3:7.

  17. Apparatus for controlled mixing in a high intensity mixer

    International Nuclear Information System (INIS)

    Crocker, Z.; Gupta, V.P.

    1982-01-01

    An apparatus and a process is disclosed for controlled mixing of a mixable material in a high intensity mixer. The system enables instantaneous, precise and continual monitoring of a batch in a high intensity mixer which heretofore could not be achieved. The process comprises the steps of feeding a batch of material into a high intensity mixer, agitating the batch in the mixer, monitoring batch temperature separately from mixer temperature and discharging the batch from the mixer when the batch temperature reaches a final predetermined level. The apparatus includes means for monitoring batch temperature in a high intensity mixer separately from mixer temperature, and means responsive to the batch temperature to discharge the batch when the batch temperature reaches a final predetermined level

  18. Vibration mixer

    Energy Technology Data Exchange (ETDEWEB)

    Alekhin, S.A.; Chernov, V.S.; Denisenko, V.V.; Gorodnyanskiy, I.F.; Prokopov, L.I.; Tikhonov, Yu.P.

    1983-01-01

    The vibration mixer is proposed which contains a housing, vibration drive with rod installed in the upper part of the mixing mechanism made in the form of a hollow shaft with blades. In order to improve intensity of mixing and dispersion of the mud, the shaft with the blades is arranged on the rod of the vibrator and is equipped with a cam coupling whose drive disc is attached to the vibration rod. The rod is made helical, while the drive disc of the cam coupling is attached to the helical surface of the rod. In addition, the vibration mixer is equipped with perforated discs installed on the ends of the rods.

  19. Topology optimization of microfluidic mixers

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe; Gersborg, Allan Roulund; Sigmund, Ole

    2009-01-01

    This paper demonstrates the application of the topology optimization method as a general and systematic approach for microfluidic mixer design. The mixing process is modeled as convection dominated transport in low Reynolds number incompressible flow. The mixer performance is maximized by altering...

  20. Pre-design mixer-settler based on phase inversion

    International Nuclear Information System (INIS)

    Widiatmo, Djarot S.W

    1998-01-01

    The mixer settler was designed to extract uranium from organic phase by n-Dodecane and to separate heavy metal from liquid waste. The mixer settler was designed to save solvent without reducing the extraction efficiency. Extraction efficiency depend on : two phase dispersion on mixing, the type of droplet formation and completeness phase separation. The mixer settler has three main part i.e. mixer chamber, droplet formation device and phase inversion column. Mixer chamber was operated in laminar mixing, the total flow rate 200 ml.second -1 . The mixer chamber dimensions was 5 cm diameter and 7 cm height. It was completed with paddle mixer 3 cm diameter, 1 cm height and the speed rotation was 300 rpm. The droplet formation device was perforated plate 5 cm diameter with 1 mm holes. Phase Inversion column dimensions was 5 cm diameter and 50 cm height. (author)

  1. Mixer Assembly for a Gas Turbine Engine

    Science.gov (United States)

    Dai, Zhongtao (Inventor); Cohen, Jeffrey M. (Inventor); Fotache, Catalin G. (Inventor); Smith, Lance L. (Inventor); Hautman, Donald J. (Inventor)

    2018-01-01

    A mixer assembly for a gas turbine engine is provided, including a main mixer with fuel injection holes located between at least one radial swirler and at least one axial swirler, wherein the fuel injected into the main mixer is atomized and dispersed by the air flowing through the radial swirler and the axial swirler.

  2. Low Voltage Current Mode Switched-Current-Mirror Mixer

    Directory of Open Access Journals (Sweden)

    Chunhua Wang

    2009-09-01

    Full Text Available A new CMOS active mixer topology can operate at 1 V supply voltage by use of SCM (switched currentmirror. Such current-mode mixer requires less voltage headroom with good linearization. Mixing is achieved with four improved current mirrors, which are alternatively activated. For ideal switching, the operation is equivalent to a conventional active mixer. This paper analyzes the performance of the SCM mixer, in comparison with the conventional mixer, demonstrating competitive performance at a lower supply voltage. Moreover, the new mixer’s die, without any passive components, is very small, and the conversion gain is easy to adjust. An experimental prototype was designed and simulated in standard chartered 0.18μm RF CMOS Process with Spectre in Cadence Design Systems. Experimental results show satisfactory mixer performance at 2.4 GHz.

  3. Realization of THz Band Mixer Using Graphene

    Directory of Open Access Journals (Sweden)

    E. Ghasemi Mizuji

    2014-05-01

    Full Text Available In this article a new method for creating mixer component in infrared and THz is suggested. Since the nonlinear property of admittance creates frequency components that do not exist in the input signal and the electrical conductivity is associated with admittance, in our work we have proven and simulated that the nonlinear property of graphene admittance can produce mixer component. The simulation results show that the mixer component is larger than other components, therefore the mixer works properly. Because of nano scale of graphene structure, this method paves the road to achieve super compact circuits.

  4. Spare mitigation/retrieval mixer pumps

    International Nuclear Information System (INIS)

    Taylor, S.

    1995-01-01

    This document presents the functional design criteria for design, analysis, fabrication, testing, and installation of a waste tank mixer pump. The mixer pump will be operated to eliminate the periodic releases of large quantities of flammable gas (e.g., hydrogen) from Hanford Site waste tanks and also to accommodate retrieval of tank waste

  5. Two-phase LMMHD mixer-development experiments

    International Nuclear Information System (INIS)

    Fabris, G.; Dunn, P.F.; Chow, J.C.F.

    1978-01-01

    The results of a series of experiments conducted to evaluate the fluid mechanical performance of various two-phase LMMHD mixer designs are presented. The results from both flow visualization studies of the local two-phase flows downstream from various mixer-element configurations and local measurements performed to characterize these flows are presented. A conceptual LMMHD mixer design is described that insures the generation of small bubbles, prevents the formation of gas slugs and separated regions, and favors the stabilization of a homogeneous foam flow

  6. Fabrication and characterization of 8.87 THz schottky barrier mixer diodes for mixer

    Science.gov (United States)

    Wang, Wenjie; Li, Qian; An, Ning; Tong, Xiaodong; Zeng, Jianping

    2018-04-01

    In this paper we report on the fabrication and characterization of GaAs-based THz schottky barrier mixer diodes. Considering the analyzed results as well as fabrication cost and complexity, a group of trade-off parameters was determined. Electron-beam lithography and air-bridge technique have been used to obtain schottky diodes with a cut off frequency of 8.87 THz. Equivalent values of series resistance, ideal factor and junction capacitance of 10.2 (1) Ω, 1.14 (0.03) and 1.76(0.03) respectively have been measured for 0.7um diameter anode devices by DC and RF measurements. The schottky barrier diodes fabrication process is fully planar and very suitable for integration in THz frequency multiplier and mixer circuits. THz Schottky barrier diodes based on such technology with 2 μm diameter anodes have been tested at 1.6 THz in a sub-harmonic mixer.

  7. A general numerical analysis of the superconducting quasiparticle mixer

    Science.gov (United States)

    Hicks, R. G.; Feldman, M. J.; Kerr, A. R.

    1985-01-01

    For very low noise millimeter-wave receivers, the superconductor-insulator-superconductor (SIS) quasiparticle mixer is now competitive with conventional Schottky mixers. Tucker (1979, 1980) has developed a quantum theory of mixing which has provided a basis for the rapid improvement in SIS mixer performance. The present paper is concerned with a general method of numerical analysis for SIS mixers which allows arbitrary terminating impedances for all the harmonic frequencies. This analysis provides an approach for an examination of the range of validity of the three-frequency results of the quantum mixer theory. The new method has been implemented with the aid of a Fortran computer program.

  8. Diffusion-Cooled Tantalum Hot-Electron Bolometer Mixers

    Science.gov (United States)

    Skalare, Anders; McGrath, William; Bumble, Bruce; LeDuc, Henry

    2004-01-01

    A batch of experimental diffusion-cooled hot-electron bolometers (HEBs), suitable for use as mixers having input frequencies in the terahertz range and output frequencies up to about a gigahertz, exploit the superconducting/normal-conducting transition in a thin strip of tantalum. The design and operation of these HEB mixers are based on mostly the same principles as those of a prior HEB mixer that exploited the superconducting/normal- conducting transition in a thin strip of niobium and that was described elsewhere.

  9. Development of a multi-channel horn mixer array for microwave imaging plasma diagnostics

    International Nuclear Information System (INIS)

    Ito, Naoki; Kuwahara, Daisuke; Nagayama, Yoshio

    2015-01-01

    Microwave to millimeter-wave diagnostics techniques, such as interferometry, reflectometry, scattering, and radiometry, have been powerful tools for diagnosing magnetically confined plasmas. The resultant measurements have clarified several physics issues, including instability, wave phenomena, and fluctuation-induced transport. Electron cyclotron emission imaging has been an important tool in the investigation of temperature fluctuations, while reflectometry has been employed to measure plasma density profiles and their fluctuations. We have developed a horn-antenna mixer array (HMA), a 50 - 110 GHz 1D antenna array, which can be easily stacked as a 2D array. This article describes an upgrade to the horn mixer array that combines well-characterized mixers, waveguide-to-microstrip line transitions, intermediate frequency amplifiers, and internal local oscillator modules using a monolithic microwave integrated circuit technology to improve system performance. We also report on the use of a multi-channel HMA system. (author)

  10. The Robust Control Mixer Module Method for Control Reconfiguration

    DEFF Research Database (Denmark)

    Yang, Z.; Blanke, M.

    1999-01-01

    into a LTI dynamical system, and furthermore multiple dynamical control mixer modules can be employed in our consideration. The H_{\\infty} control theory is used for the analysis and design of the robust control mixer modules. Finally, one practical robot arm system as benchmark is used to test the proposed......The control mixer concept is efficient in improving an ordinary control system into a fault tolerant one, especially for these control systems of which the real-time and on-line redesign of the control laws is very difficult. In order to consider the stability, performance and robustness...... of the reconfigurated system simultaneously, and to deal with a more general controller reconfiguration than the static feedback mechanism by using the control mixer approach, the robust control mixer module method is proposed in this paper. The form of the control mixer module extends from a static gain matrix...

  11. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    Jimenez, R.F.

    1994-01-01

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  12. Russian Pulsating Mixer Pump Deployment in the Gunite and Associated Tanks at ORNL

    International Nuclear Information System (INIS)

    Hatchell, Brian K.; Lewis, Ben; Johnson, Marshall A.; Randolph, J. G.

    2001-01-01

    In FY 1998, Pulsating Mixer Pump (PMP) technology, consisting of a jet mixer powered by a reciprocating air supply, was selected for deployment in one of the Gunite and Associated Tanks at Oak Ridge National Laboratory (ORNL) to mobilize settled solids. The pulsating mixer pump technology was identified during FY 1996 and FY 1997 technical exchanges between the U.S. Department of Energy (DOE) Tanks Focus Area Retrieval and Closure program, the DOE Environmental Management International Programs, and delegates from Russia as a promising technology that could be implemented in the DOE complex. During FY 1997, the pulsating mixer pump technology, provided by the Russian Integrated Mining Chemical Company, was tested at Pacific Northwest National Laboratory (PNNL) to observe its ability to suspend settled solids. Based on the results of this demonstration, ORNL and DOE staff determined that a modified pulsating mixer pump would meet project needs for remote sludge mobilization of Gunite tank sludge and reduce the cost of operation and maintenance of more expensive mixing systems. The functions and requirements of the system were developed by combining the results and recommendations from the pulsating mixer pump demonstration at PNNL with the requirements identified by staff at ORNL involved with the remediation of the Gunite and Associated Tanks. The PMP is comprised of a pump chamber, check valve, a working gas supply pipe, a discharge manifold, and four jet nozzles. The pump uses two distinct cycles, fill and discharge, to perform its mixing action. During the fill cycle, vacuum is applied to the pump chamber by an eductor, which draws liquid into the pump. When the liquid level inside the chamber reaches a certain level, the chamber is pressurized with compressed air to discharge the liquid through the jet nozzles and back into the tank to mobilize sludge and settled solids.

  13. 21 CFR 888.4210 - Cement mixer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement mixer for clinical use. 888.4210 Section... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4210 Cement mixer for clinical use. (a) Identification. A cement mixer for clinical use is a device consisting of a container intended for use in mixing...

  14. Micro-mixer/combustor

    KAUST Repository

    Badra, Jihad Ahmad; Masri, Assaad Rachid

    2014-01-01

    A micro-mixer/combustor to mix fuel and oxidant streams into combustible mixtures where flames resulting from combustion of the mixture can be sustained inside its combustion chamber is provided. The present design is particularly suitable

  15. Scale-up of mixer-settler for uranium extraction

    International Nuclear Information System (INIS)

    Santana, A.O. de.

    1990-05-01

    The aim of this work was to obtain scale-up relations for a box type mixer-settler used in uranium extraction process for chloridric leaches. Three box type units with different sizes and with the same geometry were used for scale-up of the mixer. The correlation between extraction rate and specific power input, D/T ratio (stirrer diameter/mixer length) and residence time were experimentally obtained. The results showed that the extraction increases with power input for a constant value of D/T equal to 1/3, remaining however independent from mixer sizes for a specific value of power input. This behavior was observed for power input values ranging from 100 to 750 w/m 9 . (author). 23 refs, 22 figs, 23 tabs

  16. Research of UHPC properties prepared with industrial mixer

    Science.gov (United States)

    Šerelis, E.; Vaitkevičius, V.; Kerševičius, V.

    2017-09-01

    Ultra-high performance concrete (UHPC) mixture with advanced mechanical and durability properties was created using decent Zyklos ZZ50HE mixer. Zyklos ZZ50HE rotating pan mixer is similar to mixer which has common concrete plants. In experiment UHPC was prepared with Zyklos ZZ50HE mixer and thereafter best composition was selected and prepared with industrial HPGM 1125 mixer. Experiment results revealed that UHPC with W/C=0.29 and advanced mechanical and durability properties can be prepared. In experiment tremendous amount of micro steel fibres (up to 147 kg/m3) were incorporated in UHPC. Concrete with excellent salt scaling resistance and great mechanical properties was obtained. Compressive strength was increased about 30 % from 116 MPa to 150 MPa and flexural strength was increased about 5 times from 6.7 to 36.2 MPa. Salt-scaling resistance at 40 cycles in 3 % NaCl solution varied from 0.006 kg/m2 to 0.197 kg/m2. There were a few attempts to create UHPC and UHPFRC with decent technology, however, unsuccessfully till now. In the world practice this new material is currently used in the construction of bridges and viaducts.

  17. 7 CFR 58.228 - Dump hoppers, screens, mixers and conveyors.

    Science.gov (United States)

    2010-01-01

    ... Service 1 Equipment and Utensils § 58.228 Dump hoppers, screens, mixers and conveyors. The product contact surfaces of dump hoppers, screens, mixers and conveyors which are used in the process of transferring dry... 7 Agriculture 3 2010-01-01 2010-01-01 false Dump hoppers, screens, mixers and conveyors. 58.228...

  18. Problems of bentonite rebonding of synthetic system sands in turbine mixers

    Directory of Open Access Journals (Sweden)

    A. Fedoryszyn

    2008-12-01

    Full Text Available Turbine (rotor mixers are widely used in foundries for bentonite rebonding of synthetic system sands. They form basic equipment in modern sand processing plants. Their major advantage is the short time of the rebond mixing cycle.Until now, no complete theoretical description of the process of mixing in turbine mixers has been offered. Neither does it seem reasonable to try to adapt the theoretical backgrounds of the mixing process carried out in mixers of other types, for example, rooler mixers [1], to the description of operation of the turbine mixers. Truly one can risk the statement that the individual fundamental operations of mixing in rooler mixers, like kneading, grinding, mixing and thinning, are also performed in turbine mixers. Yet, even if so, in turbine mixers these processes are proceeding at a rate and intensity different than in the roller mixers. The fact should also be recalled that the theoretical backgrounds usually relate to the preparation of sand mixtures from new components, and this considerably restricts the field of application of these descriptions when referred to rebond mixing of the system sand. The fundamentals of the process of the synthetic sand rebonding with bentonite require determination and description of operations, like disaggregation, even distribution of binder and water within the entire volume of the rebonded sand batch, sand grains coating, binder activation and aeration.This study presents the scope of research on the sand rebonding process carried out in turbine mixers. The aim has been to determine the range and specific values of the designing and operating parameters to get optimum properties of the rebonded sand as well as energy input in the process.

  19. Granular flow in static mixers by coupled DEM/CFD approach

    Directory of Open Access Journals (Sweden)

    Pezo Lato

    2016-01-01

    Full Text Available The mixing process greatly influence the mixing efficiency, as well as the quality and the price of the intermediate and/or the final product. Static mixer is used for premixing action before the main mixing process, for significant reduction of mixing time and energy consumption. This type of premixing action is not investigated in detail in the open literature. In this article, the novel numerical approach called Discrete Element Method is used for modelling of granular flow in multiple static mixer applications (1 - 3 Komax or Ross mixing elements were utilized, while the Computational Fluid Dynamic method was chosen for fluid flow modelling, using the Eulerian multiphase model. The main aim of this article is to predict the behaviour of granules being gravitationally transported in different mixer configuration and to choose the best configuration of the mixer taking into account the total particle path, the number of mixing elements and the quality of the obtained mixture. The results of the numerical simulations in the static mixers were compared to experimental results, the mixing quality is examined by RSD (relative standard deviation criterion, and the effects on the mixer type and the number of mixing elements on mixing process were studied. The effects of the mixer type and the number of mixing elements on mixing process were studied using analysis of variance (ANOVA. Mathematical modelling is used for optimization of number of Ross and Komax segments in mixer in order to gain desirable mixing results. [Projekat Ministarstva nauke Republike Srbije, br. TR31055

  20. Research on Mixer Parametric Modeling System Based on Redevelopment of ANSYS

    Directory of Open Access Journals (Sweden)

    Bin Zheng

    2015-01-01

    Full Text Available In this paper, the mixer parametric modeling system software was developed by using VB which was taken as the foreground development program, and the paper combined with ANSYS software to create the finite element model of mixer blade and cylinder for the following numerical simulation of the flow field and parameter optimization of mixer. The software user interface was developed by VB and the pre-process model was created by invoking APDL of ANSYS in background. Therefore, the operation of modeling, meshing, component-building of mixer blade and cylinder were completed by using APDL and the graphic and text were outputted and displayed on the mixer parametric modeling system user interface which was developed by VB. Practice proved that it is convenient to modify the mixer solid model created by the parametric design language of ANSYS due to the similar structure.

  1. Mixer pump test plan for double shell tank AZ-101

    International Nuclear Information System (INIS)

    STAEHR, T.W.

    1999-01-01

    Mixer pump systems have been chosen as the method for retrieval of tank wastes contained in double shell tanks at Hanford. This document describes the plan for testing and demonstrating the ability of two 300 hp mixer pumps to mobilize waste in tank AZ-101. The mixer pumps, equipment and instrumentation to monitor the test were installed by Project W-151

  2. Mixer-settler performance evaluation in actinide extraction

    International Nuclear Information System (INIS)

    Camilo, R.L.; Goncalves, M.A.; Carvalho, E.I.; Nakazone, A.K.; Araujo, B.F. de; Araujo, J.A.

    1988-07-01

    This paper deals with four conceptions of mixer-settlers used for actinide purification and recovery. By means of the uranium concentration profiles in the organic and aqueous phases, the evaluation of each mixer-settler was made. The main purpose of this work is the data acquisition, for adapting the different contactor types to actinide recovery by liquid-liquid extraction, in the nuclear fuel cycle. (autor) [pt

  3. Hot-electron bolometer terahertz mixers for the Herschel Space Observatory.

    Science.gov (United States)

    Cherednichenko, Sergey; Drakinskiy, Vladimir; Berg, Therese; Khosropanah, Pourya; Kollberg, Erik

    2008-03-01

    We report on low noise terahertz mixers (1.4-1.9 THz) developed for the heterodyne spectrometer onboard the Herschel Space Observatory. The mixers employ double slot antenna integrated superconducting hot-electron bolometers (HEBs) made of thin NbN films. The mixer performance was characterized in terms of detection sensitivity across the entire rf band by using a Fourier transform spectrometer (from 0.5 to 2.5 THz, with 30 GHz resolution) and also by measuring the mixer noise temperature at a limited number of discrete frequencies. The lowest mixer noise temperature recorded was 750 K [double sideband (DSB)] at 1.6 THz and 950 K DSB at 1.9 THz local oscillator (LO) frequencies. Averaged across the intermediate frequency band of 2.4-4.8 GHz, the mixer noise temperature was 1100 K DSB at 1.6 THz and 1450 K DSB at 1.9 THz LO frequencies. The HEB heterodyne receiver stability has been analyzed and compared to the HEB stability in the direct detection mode. The optimal local oscillator power was determined and found to be in a 200-500 nW range.

  4. The development of terahertz superconducting hot-electron bolometric mixers

    International Nuclear Information System (INIS)

    Semenov, Alexei; Richter, Heiko; Smirnov, Konstantin; Voronov, Boris; Gol'tsman, Gregory; Huebers, Heinz-Wilhelm

    2004-01-01

    We present recent advances in the development of NbN hot-electron bolometric (HEB) mixers for flying terahertz heterodyne receivers. Three important issues have been addressed: the quality of the source NbN films, the effect of the bolometer size on the spectral properties of different planar feed antennas, and the local oscillator (LO) power required for optimal operation of the mixer. Studies of the NbN films with an atomic force microscope indicated a surface structure that may affect the performance of the smallest mixers. Measured spectral gain and noise temperature suggest that at frequencies above 2.5 THz the spiral feed provides better overall performance than the double-slot feed. Direct measurements of the optimal LO power support earlier estimates made in the framework of the uniform mixer model

  5. Methodology for calculating power consumption of planetary mixers

    Science.gov (United States)

    Antsiferov, S. I.; Voronov, V. P.; Evtushenko, E. I.; Yakovlev, E. A.

    2018-03-01

    The paper presents the methodology and equations for calculating the power consumption necessary to overcome the resistance of a dry mixture caused by the movement of cylindrical rods in the body of a planetary mixer, as well as the calculation of the power consumed by idling mixers of this type. The equations take into account the size and physico-mechanical properties of mixing material, the size and shape of the mixer's working elements and the kinematics of its movement. The dependence of the power consumption on the angle of rotation in the plane perpendicular to the axis of rotation of the working member is presented.

  6. Alternate paddle configuration for improved wear resistance in the saltstone mixer

    Energy Technology Data Exchange (ETDEWEB)

    Reigel, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2013-09-23

    The Saltstone Production Facility has a 10-inch Readco-Kurimoto continuous mixer that mixes the premix dry feeds and low-level waste salt solution to make fresh (uncured) saltstone. Inspection of the mixer in January 2013 showed significant wear on the third, fourth and fifth paddle pairs after the conveying augers. A 2-inch Readco-Kurimoto continuous mixer was used to test alternate paddle configurations for use in the 10-inch mixer to decrease the wear rate on the paddles. Two wear tests were conducted to investigate a method of reducing wear on the mixer paddles. The first test (wear test 2a) had a paddle configuration similar to the currently installed 10-inch mixer in the SPF. This test established baseline wear. The second test (wear test 2b) had a reconfigured paddle arrangement that replaced the flat paddles with helical paddles for paddle pairs 2 - 6 and aligned paddle pair 1 with the augers. The intent of the reconfiguration was to more effectively convey the partially wetted dry feeds through the transition region and into the liquid feed where paddle wear is reduced due to dry feeds and salt solution being mixed at the intended water to premix ratio. The design of the helical paddles provides conveyance through the transition region to the liquid feed inlet. The alignment with the auger is aimed to provide a smoother transition (minimizing the discontinuity between the auger and paddle pair 1) into the downstream paddles. A soft metal with low wear resistance (6000 series aluminum) was used for the wear testing paddles to determine wear patterns while minimizing run time and maximizing wear rate. For the two paddle configurations tested using the scaled 2-inch Readco-Kurimoto continuous mixer, with the first six paddles after the augers replaced by the wear paddles and the remaining paddles were stainless steel. Since the 10-inch SPF mixer is designed with the liquid inlet centered over paddle pairs 5 and 6, the scaled 2-inch mixer was configured the

  7. A comparative study of ground tire rubber devulcanization using twin screw extruder and internal mixer

    Science.gov (United States)

    Ujianto, O.; Putri, D. B.; Jayatin; AWinarto, D.

    2017-07-01

    Devulcanization of ground tire rubber (GTR) was done using twin screw extruder (TSE) and internal mixer (IM). Processing parameters were varied to analyze its effect on gel content. Fourier Transform Infrared Spectroscopy (FTIR) analysis was performed as qualitative technique to confirm structural change. The devulcanized rubbers with the least gel content percentage produced in both TSE and IM were then used as filler in natural rubber (NR)/coconut coir (CC) composite preparation. Effects of gel content percentage on NR/CC composite tensile strength and elongation at break were analyzed. The results show that the gel content decreased by 41% for sample processed in TSE and 50% in IM compared to control sample. Overall, the devulcanization is influenced by high energy generated by thermal or thermo-mechanical process. FTIR spectra show chemically structural changes of GTR as C=C, CH2, CH3 with higher intensity for IM sample than its counterpart indicated devulcanization. The replacement of GTR to DGTR on NR/CC/GTR composites provided less network structures and resulted better tensile strength and elongation at break.

  8. Numerical simulation and PEPT measurements of a 3D conical helical-blade mixer: a high potential solids mixer for solid-state fermentation

    NARCIS (Netherlands)

    Schutyser, M.A.I.; Briels, W.J.; Rinzema, A.; Boom, R.M.

    2003-01-01

    Helical-blade solids mixers have a large potential as bioreactors for solid-state fermentation (SSF). Fundamental knowledge of the flow and mixing behavior is required for robust operation of these mixers. In this study predictions of a discrete particle model were compared to experiments with

  9. Planar Submillimeter-Wave Mixer Technology with Integrated Antenna

    Science.gov (United States)

    Chattopadhyay, Gautam; Mehdi, Imran; Gill, John J.; Lee, Choonsup; lombart, Muria L.; Thomas, Betrand

    2010-01-01

    High-performance mixers at terahertz frequencies require good matching between the coupling circuits such as antennas and local oscillators and the diode embedding impedance. With the availability of amplifiers at submillimeter wavelengths and the need to have multi-pixel imagers and cameras, planar mixer architecture is required to have an integrated system. An integrated mixer with planar antenna provides a compact and optimized design at terahertz frequencies. Moreover, it leads to a planar architecture that enables efficient interconnect with submillimeter-wave amplifiers. In this architecture, a planar slot antenna is designed on a thin gallium arsenide (GaAs) membrane in such a way that the beam on either side of the membrane is symmetric and has good beam profile with high coupling efficiency. A coplanar waveguide (CPW) coupled Schottky diode mixer is designed and integrated with the antenna. In this architecture, the local oscillator (LO) is coupled through one side of the antenna and the RF from the other side, without requiring any beam sp litters or diplexers. The intermediate frequency (IF) comes out on a 50-ohm CPW line at the edge of the mixer chip, which can be wire-bonded to external circuits. This unique terahertz mixer has an integrated single planar antenna for coupling both the radio frequency (RF) input and LO injection without any diplexer or beamsplitters. The design utilizes novel planar slot antenna architecture on a 3- mthick GaAs membrane. This work is required to enable future multi-pixel terahertz receivers for astrophysics missions, and lightweight and compact receivers for planetary missions to the outer planets in our solar system. Also, this technology can be used in tera hertz radar imaging applications as well as for testing of quantum cascade lasers (QCLs).

  10. Quantum limited quasiparticle mixers at 100 GHz

    International Nuclear Information System (INIS)

    Mears, C.A; Hu, Qing; Richards, P.L.; Worsham, A.H.; Prober, D.E.; Raeisaenen, A.V.

    1990-09-01

    We have made accurate measurements of the noise and gain of superconducting-insulating-superconducting (SIS) mixers employing small area (1μm 2 ) Ta/Ta 2 O 5 /Pb 0.9 Bi 0.1 tunnel junctions. We have measured an added mixer noise of 0.61 +/- 0.31 quanta at 95.0 GHz, which is within 25 percent of the quantum limit of 0.5 quanta. We have carried out a detailed comparison between theoretical predictions of the quantum theory of mixing and experimentally measured noise and gain. We used the shapes of I-V curves pumped at the upper and lower sideband frequencies to deduce values of the embedding admittances at these frequencies. Using these admittances, the mixer noise and gain predicted by quantum theory are in excellent agreement with experiment. 21 refs., 9 figs

  11. Numerical Simulation of the Oscillations in a Mixer: An Internal Aeroacoustic Feedback System

    Science.gov (United States)

    Jorgenson, Philip C. E.; Loh, Ching Y.

    2004-01-01

    The space-time conservation element and solution element method is employed to numerically study the acoustic feedback system in a high temperature, high speed wind tunnel mixer. The computation captures the self-sustained feedback loop between reflecting Mach waves and the shear layer. This feedback loop results in violent instabilities that are suspected of causing damage to some tunnel components. The computed frequency is in good agreement with the available experimental data. The physical phenomena are explained based on the numerical results.

  12. Far-ir heterodyne radiometric measurements with quasioptical Schottky diode mixers

    International Nuclear Information System (INIS)

    Fetterman, H.R.; Tannenwald, P.E.; Clifton, B.J.; Parker, C.D.; Fitzgerald, W.D.; Erickson, N.R.

    1978-01-01

    We have made heterodyne radiometric measurements with GaAs Schottky diode mixers, mounted in a corner-reflector configuration, over the spectral range 170 μm to 1 mm. At 400 μm, system noise temperatures of 9700 K DSB (NEP=1.4 x 10 - 19 W/Hz) and mixer noise temperatures of 5900 K have been achieved. This same quasioptical mixer has also been used to generate 10 - 7 W of tunable radiation suitable for spectroscopic applications

  13. Numerical simulation and PEPT measurements of a 3D conical helical-bla de mixer: A high potential solids mixer for solid-state fermentation

    NARCIS (Netherlands)

    Schutyser, M.A.I.; Schutyser, M.A.I.; Briels, Willem J.; Rinzema, A.; Boom, R.M.; Boom, R.M.

    2003-01-01

    Helical-blade solids mixers have a large potential as bioreactors for solid-state fermentation (SSF). Fundamental knowledge of the flow and mixing behavior is required for robust operation of these mixers. In this study predictions of a discrete particle model were compared to experiments with

  14. Flow regimes in a T-mixer operating with a binary mixture

    Science.gov (United States)

    Camarri, Simone; Siconolfi, Lorenzo; Galletti, Chiara; Salvetti, Maria Vittoria

    2015-11-01

    Efficient mixing in small volumes is a key target in many processes. Among the most common micro-devices, passive T-shaped micro-mixers are widely used. For this reason, T-mixers have been studied in the literature and its working flow regimes have been identified. However, in most of the available theoretical studies it is assumed that only one working fluid is used, i.e. that the same fluid at the same thermodynamic conditions is entering the two inlet conduits of the mixer. Conversely, the practical use of micro-devices often involves the mixing of two different fluids or of the same fluid at different thermodynamic conditions. In this case flow regimes significantly different than those observed for a single working fluid may occur. The present work aims at investigating the flow regimes in a T-mixers when water at two different temperatures, i.e. having different viscosity and density, is entering the mixer. The effect of the temperature difference on the flow regimes in a 3D T-mixer is investigated by DNS and stability analysis and the results are compared to the case in which a single working fluid is employed.

  15. Quasi-optical antenna-mixer-array design for terahertz frequencies

    Science.gov (United States)

    Guo, Yong; Potter, Kent A.; Rutledge, David B.

    1992-01-01

    A new quasi-optical antenna-mixer-array design for terahertz frequencies is presented. In the design, antenna and mixer are combined into an entity, based on the technology in which millimeter-wave horn antenna arrays have been fabricated in silicon wafers. It consists of a set of forward- and backward-looking horns made with a set of silicon wafers. The front side is used to receive incoming signal, and the back side is used to feed local oscillator signal. Intermediate frequency is led out from the side of the array. Signal received by the horn array is picked up by antenna probes suspended on thin silicon-oxynitride membranes inside the horns. Mixer diodes will be located on the membranes inside the horns. Modeling of such an antenna-mixer-array design is done on a scaled model at microwave frequencies. The impedance matching, RF and LO isolation, and patterns of the array have been tested and analyzed.

  16. Development of air pulsed ejector mixer settlers of different capacities

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopalan, C V; Periasamy, K; Koganti, S B [Reprocessing Programme, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1994-06-01

    Nuclear industry has made significant contributions in the development of liquid-liquid contactors, for the separation of one or more solutes from feed solutions wherein they provide a more economical alternative compared to other unit operations. The various equipment that are used can be broadly classified into three categories: (1) mixer settlers (2) liquid pulsed sieve plate columns (3) centrifugal contactors. Each one has its own merits and demerits. Mixer settlers score over the other contactors in their simple design and reliable operation over a wide range of process conditions. Air pulsed mixer settlers of different designs are in use in the fuel reprocessing industry. The present paper describes the development of a new type of mixer settler based on ejector as the mixing device. (author). 7 refs., 3 figs., 1 tab.

  17. A Matlab-Based Graphical User Interface for Simulation and Control Design of a Hydrogen Mixer

    Science.gov (United States)

    Richter, Hanz; Figueroa, Fernando

    2003-01-01

    A Graphical User Interface (GUI) that facilitates prediction and control design tasks for a propellant mixer is described. The Hydrogen mixer is used in rocket test stand operations at the NASA John C. Stennis Space Center. The mixer injects gaseous hydrogen (GH2) into a stream of liquid hydrogen (LH2) to obtain a combined flow with desired thermodynamic properties. The flows of GH2 and LH2 into the mixer are regulated by two control valves, and a third control valve is installed at the exit of the mixer to regulate the combined flow. The three valves may be simultaneously operated in order to achieve any desired combination of total flow, exit temperature and mixer pressure within the range of operation. The mixer, thus, constitutes a three-input, three-output system. A mathematical model of the mixer has been obtained and validated with experimental data. The GUI presented here uses the model to predict mixer response under diverse conditions.

  18. A Multidisciplinary Approach to Mixer-Ejector Analysis and Design

    Science.gov (United States)

    Hendricks, Eric, S.; Seidel, Jonathan, A.

    2012-01-01

    The design of an engine for a civil supersonic aircraft presents a difficult multidisciplinary problem to propulsion system engineers. There are numerous competing requirements for the engine, such as to be efficient during cruise while yet quiet enough at takeoff to meet airport noise regulations. The use of mixer-ejector nozzles presents one possible solution to this challenge. However, designing a mixer-ejector which will successfully address both of these concerns is a difficult proposition. Presented in this paper is an integrated multidisciplinary approach to the analysis and design of these systems. A process that uses several low-fidelity tools to evaluate both the performance and acoustics of mixer-ejectors nozzles is described. This process is further expanded to include system-level modeling of engines and aircraft to determine the effects on mission performance and noise near airports. The overall process is developed in the OpenMDAO framework currently being developed by NASA. From the developed process, sample results are given for a notional mixer-ejector design, thereby demonstrating the capabilities of the method.

  19. Study on velocity distribution in a pool by submersible mixers

    International Nuclear Information System (INIS)

    Tian, F; Shi, W D; Lu, X N; Chen, B; Jiang, H

    2012-01-01

    To study the distribution of submersible mixers and agitating effect in the sewage treatment pool, Pro/E software was utilized to build the three-dimensional model. Then, the large-scale computational fluid dynamics software FLUENT6.3 was used. ICEM software was used to build unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. The macro fluid field and each section velocity flow field distribution were analyzed to observe the efficiency of each submersible mixer. The average velocity and mixing area in the sewage pool were studied simultaneously. Results show that: the preferred project B, two submersible mixers speed is 980 r/min, and setting angles are all 30°. Fluid mixing area in the pool has reached more than 95%. Under the action of two mixers, the fluid in the sewage pool form a continuous circulating water flow. The fluid is mixed adequately and average velocity of fluid in the pool is at around 0.241m/s, which agreed with the work requirements. Consequently it can provide a reference basis for practical engineering application of submersible mixers by using this method.

  20. Microsurgical techniques in temporal lobe epilepsy.

    Science.gov (United States)

    Alonso Vanegas, Mario A; Lew, Sean M; Morino, Michiharu; Sarmento, Stenio A

    2017-04-01

    Temporal lobe resection is the most prevalent epilepsy surgery procedure. However, there is no consensus on the best surgical approach to treat temporal lobe epilepsy. Complication rates are low and efficacy is very high regarding seizures after such procedures. However, there is still ample controversy regarding the best surgical approach to warrant maximum seizure control with minimal functional deficits. We describe the most frequently used microsurgical techniques for removal of both the lateral and mesial temporal lobe structures in the treatment of medically intractable temporal lobe epilepsy (TLE) due to mesial temporal sclerosis (corticoamygdalohippocampectomy and selective amygdalohippocampectomy). The choice of surgical technique appears to remain a surgeon's preference for the near future. Meticulous surgical technique and thorough three-dimensional microsurgical knowledge are essentials for obtaining the best results. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  1. The development of mixer machine for organic animal feed production: Proposed study

    Science.gov (United States)

    Leman, A. M.; Wahab, R. Abdul; Zakaria, Supaat; Feriyanto, Dafit; Nor, M. I. F. Che Mohd; Muzarpar, Syafiq

    2017-09-01

    Mixer machine plays a major role in producing homogenous composition of animal feed. Long time production, inhomogeneous and minor agglomeration has been observed by existing mixer. Therefore, this paper proposed continuous mixer to enhance mixing efficiency with shorter time of mixing process in order to abbreviate the whole process in animal feed production. Through calculation of torque, torsion, bending, power and energy consumption will perform in mixer machine process. Proposed mixer machine is designed by two layer buckets with purpose for continuity of mixing process. Mixing process was performed by 4 blades which consists of various arm length such as 50, 100,150 and 225 mm in 60 rpm velocity clockwise rotation. Therefore by using this machine will produce the homogenous composition of animal feed through nutrition analysis and short operation time of mixing process approximately of 5 minutes. Therefore, the production of animal feed will suitable for various animals including poultry and aquatic fish. This mixer will available for various organic material in animal feed production. Therefore, this paper will highlights some areas such as continues animal feed supply chain and bio-based animal feed.

  2. A flicker noise/IM3 cancellation technique for active mixer using negative impedance

    NARCIS (Netherlands)

    Cheng, W.; Annema, Anne J.; Wienk, Gerhardus J.M.; Nauta, Bram

    2013-01-01

    Abstract—This paper presents an approach to simultaneously cancel flicker noise and IM3 in Gilbert-type mixers, utilizing negative impedances. For proof of concept, two prototype double-balanced mixers in 0.16- m CMOS are fabricated. The first demonstration mixer chip was optimized for full IM3

  3. Conversion Matrix Analysis of SiGe HBT Gilbert Cell Mixers

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Vidkjær, Jens; Krozer, Viktor

    2004-01-01

    The frequency response of SiGe HBT active mixers based on the Gilbert cell topology is analyzed theoretically. The time-varying operation of the Gilbert cell mixer is taken into account by applying conversion matrix analysis. The main bandwidth limiting mechanisms experienced in SiGe HBT Gilbert ...

  4. MOSFET-Only Mixer/IIR Filter with Gain using Parametric Amplification

    DEFF Research Database (Denmark)

    Custódio, José R.; Oliveira, J.; Oliveira, L. B.

    2010-01-01

    This paper describes the design of a discrete-time passive Mixer/IIR filter. The use of an improved MOS Parametric Amplification leads to a moderate gain in the signal path and improved noise performance, instead of the conversion loss inherent to passive mixers. Simulation results demonstrate th...

  5. PROTOTIPE ALAT PENGEKSTRAK PATI SAGU TIPE MIXER ROTARY BLADE BERTENAGA MOTOR BAKAR Prototype of Mixer Rotary Blade of Sago Starch Extractor Powered by Internal Combustion Engine

    Directory of Open Access Journals (Sweden)

    Darma Darma

    2012-05-01

    Full Text Available Papua and West Papua Province have a large potential of sago. Approximately 994,000 hectares, mostly natural sago forest was existed in this area. Sago starch has long been an important source of nutrition troughout Papua. Product of sago palm is not only starch as source of carbohydrate for food stuff, but also for basic material of industries such as paper, plywood, hardboard, and food indutries. Traditional methods are used for starch extraction in almost all part of Papu, which is not efficient and production capacity is very low. The effort to increase sago starch production could be carry out by introducing mechanical equipment (traditional to mechanized processing. The objective of this research was to design mixer rotary blade of sago starch extraction powered by internal combustion engine. The result was prototype of mechanical sago starch extractor. The prototype has high performance with extraction capacity 160 kg of disintegrated pith per hour or equal to 33 kg of wet starch per hour, extractable starch more than 99 % while starch losses in hampas less lhan 1 %. Hopefully, application of this machine to the sago farmer will transform agricultural system from subsistence to commercial. It means that increasing of economic income. In conclusion, technically and economically this prototype was feasible. ABSTRAK Provinsi Papua dan Papua Barat memiliki potensi sagu yang sangat besar. Sekitar 994.000 hektar yang sebagian besar merupakan hutan sagu alam terdapat di kedua provinsi ini. Pati sagu telah lama digunakan sebagai sumber nutrisi bagi penduduk asli papua. Pati sagu tidak hanya digunakan sebagai sumber karbohidrat, namun juga digunakan seba- gai bahan dasar industri kertas, plywood, hardbord, dan pangan. Pengolahan sagu secara tradisional yang dilakukan oleh masyarakat tidak efisien dan kapasitas produksinya sangat rendah. Peningkatan produksi dapat dilakukan dengan mengintroduksi peralatan pengolahan mekanis untuk merubah metode

  6. Twin Screw Mixer/Fine Grind Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The 40-mm Twin-Screw Mixer/Extruder (TSE) pilot plant is a continuous, remotely operated, flexible facility that can significantly enhance safety and environmental...

  7. CONTINUOUS PRODUCTION OF HYDROXYPROPYL STARCH IN A STATIC MIXER REACTOR

    NARCIS (Netherlands)

    LAMMERS, G; STAMHUIS, EJ; BEENACKERS, AACM

    A novel type of reactor for the chemical derivatization of starch pastes is presented. The design is based on the application of static mixers. The reactor shows excellent plug flow behaviour with a Peclet number of about 100. The viscosity behaviour of concentrated starch pastes in the static mixer

  8. Numerical Investigation on Aerodynamic and Combustion Performance of Chevron Mixer Inside an Afterburner.

    Science.gov (United States)

    Yong, Shan; JingZhou, Zhang; Yameng, Wang

    2014-11-01

    To improve the performance of the afterburner for the turbofan engine, an innovative type of mixer, namely, the chevron mixer, was considered to enhance the mixture between the core flow and the bypass flow. Computational fluid dynamics (CFD) simulations investigated the aerodynamic performances and combustion characteristics of the chevron mixer inside a typical afterburner. Three types of mixer, namely, CC (chevrons tilted into core flow), CB (chevrons tilted into bypass flow), and CA (chevrons tilted into core flow and bypass flow alternately), respectively, were studied on the aerodynamic performances of mixing process. The chevrons arrangement has significant effect on the mixing characteristics and the CA mode seems to be advantageous for the generation of the stronger streamwise vortices with lower aerodynamic loss. Further investigations on combustion characteristics for CA mode were performed. Calculation results reveal that the local temperature distribution at the leading edge section of flame holder is improved under the action of streamwise vortices shedding from chevron mixers. Consequently, the combustion efficiency increased by 3.5% compared with confluent mixer under the same fuel supply scheme.

  9. Design and Fabrication of a Foundry Sand Mixer Using Locally ...

    African Journals Online (AJOL)

    Most small foundry shops mix their sand manually which is not efficient since homogenous mix cannot be guaranteed and even when foundry mixer are available most of them are imported costing the nation huge foriegn exchange. A foundry sand mixer capable of mixing foundry sand has been designed and fabricated ...

  10. Superconducting terahertz mixer using a transition-edge microbolometer

    Science.gov (United States)

    Prober, D. E.

    1993-01-01

    We present a new device concept for a mixer element for THz frequencies. This uses a superconducting transition-edge microbridge biased at the center of its superconducting transition near 4.2 K. It is fed from an antenna or waveguide structure. Power from a local oscillator and an RF signal produce a temperature and resulting resistance variation at the difference frequency. The new aspect is the use of a very short bridge in which rapid (less than 0.1 ns) outdiffusion of hot electrons occurs. This gives large intermediate frequency (IF) response. The mixer offers about 4 GHz IF bandwidth, about 80 ohm RF resistive impedance, good match to the IF amplifier, and requires only 1-20 nW of local oscillator power. The upper RF frequency is determined by antenna or waveguide properties. Predicted mixer conversion efficiency is 1/8, and predicted double-sideband receiver noise temperatures are 260 and 90 K for transition widths of 0.1 and 0.5 Tc, respectively.

  11. Side-band-separating heterodyne mixer for band 9 of ALMA.

    NARCIS (Netherlands)

    Mena, F. P.; Baryshev, A. M.; Kooi, J.; Lodewijk, C. F. J.; Gerlofsma, G.; Hesper, R.; Wild, W.; Shen, XC; Lu, W; Zhang, J; Dou, WB

    2006-01-01

    Here we present the realization of a side-band-separating (2SB) heterodyne mixer for the frequency range from 602 to 720 GHz (corresponding to ALMA band 9). The mixer, in brief, consists of a quadrature hybrid, two LO injectors, two SIS junctions, and three dumping loads. All the parts were modeled

  12. Numerical investigation of the effects of geometric parameters on transverse motion with slanted-groove micro-mixers

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Seung Joo; Cho, Jae Yong; Choi, Se Bin; Lee, Joon Sang [School of Mechanical Engineering, Yonsei University, Seoul (Korea, Republic of)

    2016-08-15

    We investigated hydrodynamic phenomena inside several passive microfluidic mixers using a Lattice Boltzmann method (LBM) based on particle mesoscopic kinetic equations. Mixing processes were simulated in a Slanted grooved micro-mixer (SGM), a Staggered herringbone grooved micro-mixer (SHM), and a Bi-layered staggered herringbone grooved micro-mixer (BSHM). Then, the effects of six geometric mixer parameters (i.e., groove height to channel height ratio, groove width to groove pitch length ratio, groove pitch to groove height ratio, groove intersection angle, herringbone groove asymmetric ratio and bi-layered groove asymmetric ratio) on mixing were investigated using computed cross-flow velocity and helicity density distributions in the flow cross-section. We demonstrated that helicity density provides sufficient information to analyze micro helical motion within a micro-mixer, allowing for micro-mixer design optimization.

  13. Sandwich-format 3D printed microfluidic mixers: a flexible platform for multi-probe analysis

    International Nuclear Information System (INIS)

    Kise, Drew P; Reddish, Michael J; Brian Dyer, R

    2015-01-01

    We report on a microfluidic mixer fabrication platform that increases the versatility and flexibility of mixers for biomolecular applications. A sandwich-format design allows the application of multiple spectroscopic probes to the same mixer. A polymer spacer is ‘sandwiched’ between two transparent windows, creating a closed microfluidic system. The channels of the mixer are defined by regions in the polymer spacer that lack material and therefore the polymer need not be transparent in the spectral region of interest. Suitable window materials such as CaF 2 make the device accessible to a wide range of optical probe wavelengths, from the deep UV to the mid-IR. In this study, we use a commercially available 3D printer to print the polymer spacers to apply three different channel designs into the passive, continuous-flow mixer, and integrated them with three different spectroscopic probes. All three spectroscopic probes are applicable to each mixer without further changes. The sandwich-format mixer coupled with cost-effective 3D printed fabrication techniques could increase the applicability and accessibility of microfluidic mixing to intricate kinetic schemes and monitoring chemical synthesis in cases where only one probe technique proves insufficient. (paper)

  14. Airfoil-shaped micro-mixers for reducing fouling on membrane surfaces

    Science.gov (United States)

    Ho, Clifford K; Altman, Susan J; Clem, Paul G; Hibbs, Michael; Cook, Adam W

    2012-10-23

    An array of airfoil-shaped micro-mixers that enhances fluid mixing within permeable membrane channels, such as used in reverse-osmosis filtration units, while minimizing additional pressure drop. The enhanced mixing reduces fouling of the membrane surfaces. The airfoil-shaped micro-mixer can also be coated with or comprised of biofouling-resistant (biocidal/germicidal) ingredients.

  15. Development of a micro-mixer-settler for nuclear solvent extraction

    International Nuclear Information System (INIS)

    Shekhar Kumar; Bijendra Kumar; Sampath, M.; Sivakumar, D.; Kamachi Mudali, U.; Natarajan, R.

    2012-01-01

    Nuclear solvent extraction was traditionally performed with packed columns, pulse columns, mixer-settlers and centrifugal extractors. However for rapid separations at micro-flow level, micro mixer-settlers were desired and in the past, few of them were actually designed and operated in nuclear solvent extraction research. In the current era of micro-reactor and microchannel devices, there is a renewed interest for micro-mixer-settlers for costly solvents and specialty solutes where small flow-rate is not an issue. In this article, development of a simple but effective micro-mixer-settler for nuclear solvent extraction is reported. The developed unit was tested with 30% TBP/n-dodecane/nitric acid system and in both the regimes of mass transfer c → d (mass transfer from continuous phase to dispersed phase, also written as c → d) and d → c (mass transfer from dispersed phase to continuous phase, also written as d → c) nearly 100% efficiency was observed in extraction as well as stripping modes of operation. (author)

  16. Wideband Low Side Lobe Aperture Coupled Patch Phased Array Antennas

    Science.gov (United States)

    Poduval, Dhruva

    Low profile printed antenna arrays with wide bandwidth, high gain, and low Side Lobe Level (SLL) are in great demand for current and future commercial and military communication systems and radar. Aperture coupled patch antennas have been proposed to obtain wide impedance bandwidths in the past. Aperture coupling is preferred particularly for phased arrays because of their advantage of integration to other active devices and circuits, e.g. phase shifters, power amplifiers, low noise amplifiers, mixers etc. However, when designing such arrays, the interplay between array performance characteristics, such as gain, side lobe level, back lobe level, mutual coupling etc. must be understood and optimized under multiple design constraints, e.g. substrate material properties and thicknesses, element to element spacing, and feed lines and their orientation and arrangements with respect to the antenna elements. The focus of this thesis is to investigate, design, and develop an aperture coupled patch array with wide operating bandwidth (30%), high gain (17.5 dBi), low side lobe level (20 dB), and high Forward to Backward (F/B) ratio (21.8 dB). The target frequency range is 2.4 to 3 GHz given its wide application in WLAN, LTE (Long Term Evolution) and other communication systems. Notwithstanding that the design concept can very well be adapted at other frequencies. Specifically, a 16 element, 4 by 4 planar microstrip patch array is designed using HFSS and experimentally developed and tested. Starting from mutual coupling minimization a corporate feeding scheme is designed to achieve the needed performance. To reduce the SLL the corporate feeding network is redesigned to obtain a specific amplitude taper. Studies are conducted to determine the optimum location for a metallic reflector under the feed line to improve the F/B. An experimental prototype of the antenna was built and tested validating and demonstrating the performance levels expected from simulation predictions

  17. Matlab GUI for a Fluid Mixer

    Science.gov (United States)

    Barbieri, Enrique

    2005-01-01

    The Test and Engineering Directorate at NASA John C. Stennis Space Center developed an interest to study the modeling, evaluation, and control of a liquid hydrogen (LH2) and gas hydrogen (GH2) mixer subsystem of a ground test facility. This facility carries out comprehensive ground-based testing and certification of liquid rocket engines including the Space Shuttle Main engine. A software simulation environment developed in MATLAB/SIMULINK (M/S) will allow NASA engineers to test rocket engine systems at relatively no cost. In the progress report submitted in February 2004, we described the development of two foundation programs, a reverse look-up application using various interpolation algorithms, a variety of search and return methods, and self-checking methods to reduce the error in returned search results to increase the functionality of the program. The results showed that these efforts were successful. To transfer this technology to engineers who are not familiar with the M/S environment, a four-module GUI was implemented allowing the user to evaluate the mixer model under open-loop and closed-loop conditions. The progress report was based on an udergraduate Honors Thesis by Ms. Jamie Granger Austin in the Department of Electrical Engineering and Computer Science at Tulane University, during January-May 2003, and her continued efforts during August-December 2003. In collaboration with Dr. Hanz Richter and Dr. Fernando Figueroa we published these results in a NASA Tech Brief due to appear this year. Although the original proposal in 2003 did not address other components of the test facility, we decided in the last few months to extend our research and consider a related pressurization tank component as well. This report summarizes the results obtained towards a Graphical User Interface (GUI) for the evaluation and control of the hydrogen mixer subsystem model and for the pressurization tank each taken individually. Further research would combine the two

  18. Predicting bulk powder flow dynamics in a continuous mixer operating in transitory regimes

    OpenAIRE

    Ammarcha , Chawki; Gatumel , Cendrine; Dirion , Jean-Louis; Cabassud , Michel; Mizonov , Vadim; Berthiaux , Henri

    2012-01-01

    International audience; Over recent years there has been increasing interest in continuous powder mixing processes, due mainly to the development of on-line measurement techniques. However, our understanding of these processes remains limited, particularly with regard to their flow and mixing dynamics. In the present work, we study the behaviour of a pilot-scale continuous mixer during transitory regimes, in terms of hold-up weight and outflow changes. We present and discuss experimental resu...

  19. 3D-printed conductive static mixers enable all-vanadium redox flow battery using slurry electrodes

    Science.gov (United States)

    Percin, Korcan; Rommerskirchen, Alexandra; Sengpiel, Robert; Gendel, Youri; Wessling, Matthias

    2018-03-01

    State-of-the-art all-vanadium redox flow batteries employ porous carbonaceous materials as electrodes. The battery cells possess non-scalable fixed electrodes inserted into a cell stack. In contrast, a conductive particle network dispersed in the electrolyte, known as slurry electrode, may be beneficial for a scalable redox flow battery. In this work, slurry electrodes are successfully introduced to an all-vanadium redox flow battery. Activated carbon and graphite powder particles are dispersed up to 20 wt% in the vanadium electrolyte and charge-discharge behavior is inspected via polarization studies. Graphite powder slurry is superior over activated carbon with a polarization behavior closer to the standard graphite felt electrodes. 3D-printed conductive static mixers introduced to the slurry channel improve the charge transfer via intensified slurry mixing and increased surface area. Consequently, a significant increase in the coulombic efficiency up to 95% and energy efficiency up to 65% is obtained. Our results show that slurry electrodes supported by conductive static mixers can be competitive to state-of-the-art electrodes yielding an additional degree of freedom in battery design. Research into carbon properties (particle size, internal surface area, pore size distribution) tailored to the electrolyte system and optimization of the mixer geometry may yield even better battery properties.

  20. Development of an enzyme fluidized bed reactor equipped with static mixers: application to lactose hydrolysis in whey

    Energy Technology Data Exchange (ETDEWEB)

    Fauquex, P F; Flaschel, E; Renken, A

    1984-01-01

    Reactor operation with immobilized enzymes in fixed bed arrangement is often impaired due to the presence of finely divided solid matter, adsorbing substances or gas. The fluidized bed reactor would be applied in such cases owing to a limited pressure drop, a controlled voidage, and the avoidance of perforated plates for catalyst retention. Since enzymic reactions are often slow processes, catalysts of high external surface area should be provided together with sufficient time. However, classical fluidized beds suffer from hydrodynamic instability under these conditions. Therefore, a new reactor design was developed which used motionless mixers as internals. Fluidized bed reactors equipped with internals exhibit an outstanding hydrodynamic stability accompanied by an increase of the operating range in terms of flow rate by a factor of 4 compared to the classical fluidized bed. Results are presented, with emphasis on the backmixing and expansion characteristics. Various motionless mixers were investigated in columns of 39 and 150 mm in diameter. The fluidized bed equipped with internals was used for lactose hydrolysis in partially deproteinized whey. The lactase from Aspergillus niger immobilized on silica gel particles of 125-160 molm had a half-life of approximately 1 mo.

  1. Antenna-coupled 30 THz hot electron bolometer mixers

    OpenAIRE

    Shcherbatenko, M.; Lobanov, Y.; Benderov, O.; Shurakov, A.; Ignatov, A.; Titova, N.; Finkel, M.; Maslennikov, S.; Kaurova, N.; Voronov, B.M.; Rodin, A.; Klapwijk, T.M.; Gol'tsman, G.N.

    2015-01-01

    We report on design and characterization of a superconducting Hot Electron Bolometer Mixer integrated with a logarithmic spiral antenna for mid-IR range observations. The antenna parameters have been adjusted to achieve the ultimate performance at 10 ?m (30 THz) range where O3, NH3, CO2, CH4, N2O, …. lines in the Earth’s atmosphere, in planetary atmospheres and in the interstellar space can be observed. The HEB mixer is made of a thin NbN film deposited onto a GaAs substrate. To couple the ra...

  2. Acceptance test report: Field test of mixer pump for 241-AN-107 caustic addition project

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1997-01-01

    The field acceptance test of a 75 HP mixer pump (Hazleton serial number N-20801) installed in Tank 241-AN-107 was conducted from October 1995 thru February 1996. The objectives defined in the acceptance test were successfully met, with two exceptions recorded. The acceptance test encompassed field verification of mixer pump turntable rotation set-up and operation, verification that the pump instrumentation functions within established limits, facilitation of baseline data collection from the mixer pump mounted ultrasonic instrumentation, verification of mixer pump water flush system operation and validation of a procedure for its operation, and several brief test runs (bump) of the mixer pump

  3. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    2000-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications

  4. Conversion Matrix Analysis of GaAs HEMT Active Gilbert Cell Mixers

    DEFF Research Database (Denmark)

    Jiang, Chenhui; Johansen, Tom Keinicke; Krozer, Viktor

    2006-01-01

    In this paper, the nonlinear model of the GaAs HEMT active Gilbert cell mixer is investigated. Based on the model, the conversion gain expression of active Gilbert cell mixers is derived theoretically by using conversion matrix analysis method. The expression is verified by harmonic balance simul...

  5. Low noise Nb-SIS mixers at far above the gap frequency

    NARCIS (Netherlands)

    Gao, [No Value; vandeStadt, H; Jegers, JBM; Kovtonyuk, S; Hulshoff, W; Whyborn, ND; Klapwijk, TM; deGraauw, T; Liao, FJ; Liu, JY

    1996-01-01

    There are great interests in developing Nb SIS mixers because of the extremely low noise temperatures and because of the need of low local oscillator (LO) power. Several groups have demonstrated experimentally that Nb SIS mixers with integrated tuning elements can perform near the quantum noise

  6. A simple image-reject mixer based on two parallel phase modulators

    Science.gov (United States)

    Hu, Dapeng; Zhao, Shanghong; Zhu, Zihang; Li, Xuan; Qu, Kun; Lin, Tao; Zhang, Kun

    2018-02-01

    A simple photonic microwave image-reject mixer (IRM) using two parallel phase modulators is proposed. First, a photonic microwave mixer with phase shift ability is achieved using two parallel phase modulators (PMs), an optical bandpass filter, three polarization controllers, three polarization beam splitters and two balanced photodetectors. At the output of the mixer, two frequency downconverted signals with tunable frequency difference can be obtained. By adjusting the phase difference as 90° and utilizing an electrical 90° hybrid, the useless components can be eliminated, and the image reject operation is realized. The key advantage of the proposed scheme is the usage of PM, which avoid the DC bias shifting problem and make the system simple and stable. A simulation is performed to verify the proposed scheme, a relative - 90° or 90° phase shift can be obtained between the two output ports of the photonic microwave mixer, at the output of the IRM, 60 dB image-reject ratio is obtained.

  7. PEMISAHAN Zr – Hf SECARA SINAMBUNG MENGGUNAKAN MIXER SETTLER

    Directory of Open Access Journals (Sweden)

    Dwi Biyantoro

    2017-01-01

    Full Text Available ABSTRAK PEMISAHAN Zr – Hf SECARA SINAMBUNG MENGGUNAKANMIXER SETTLER. Telah dilakukan pemisahanZr – Hf secara sinambung menggunakan pengaduk pengenap (mixer settler 16 stage. Larutan umpan adalah zirkon nitrat dengan kadar Zr = 30786 ppm dan Hf = 499 ppm. Ekstraktan dipakai adalah solven 60 % TBP dalam kerosen dan larutan scrubbingyang dipakai adalah asam nitrat 1 M. Umpan masuk pada stageke 5 dikontakkan secara berlawanan arah dengan solven masuk pada stage ke 16 dan larutan scrubbing masuk pada stage ke 1. Tujuan penelitian ini adalah memisahkan unsur Zr dan Hf dari hasil olah pasir zirkon menggunakan solven TBP dengan alat mixer settler16 stage. Analisis umpan dan hasil proses pemisahan untuk zirkonium (Zr dilakukan dengan menggunakan alat pendar sinar-X, sedangkananalisis unsur hafnium (Hf menggunakan Analisis Pengaktifan Neutron (APN. Parameter penelitian dilakukan dengan variasi keasaman asam nitrat dalam umpan dan variasi waktu pada berbagai laju pengadukan. Hasil penelitian pemisahan unsur Zr dengan Hf diperolehkondisi optimum pada keasaman umpan 4 N HNO3, keseimbangan dicapai setelah 3jam dan laju pengadukan 3300 rpm. Hasil ekstrak  unsur zirkon (Zr diperoleh kadar sebesar 28577 ppm dengan efisiensi 92,76 % serta kadar pengotor hafnium (Hf sebesar 95 ppm. Kata Kunci: pemisahan Zr, Hf, ekstraksi, mixer settler, alat pendar sinar-X, APN. ABSTRACT SEPARATION of Zr - Hf CONTINUOUSLY USE THE MIXER SETTLER. Separation of Zr - Hf continuously using mixer settler 16 stage has been done. The feed solution is zircon nitrate concentration of Zr = 30786 ppm  and Hf = 499 ppm. As the solvent used extractant 60 % TBP in 40 % kerosene. Nitric acid solution used srubbing 1 M. The feed entered into stage to 5 is contacted with solvents direction on the stage to 16 and the scrubbing solution enter the stage to 1. The purpose of this study is to separate Zr and Hf of the results from the process of zircon sand using solvent TBP using 16 stage

  8. Safety basis for the 241-AN-107 mixer pump installation and caustic addition

    International Nuclear Information System (INIS)

    Van Vleet, R.J.

    1994-01-01

    This safety Basis was prepared to determine whether or not the proposed activities of installing a 76 HP jet mixer pump and the addition of approximately 50,000 gallons of 19 M (50:50 wt %) aqueous caustic are within the safety envelope as described by Tank Farms (chapter six of WHC-SD-WM-ISB-001, Rev. 0). The safety basis covers the components, structures and systems for the caustic addition and mixer pump installation. These include: installation of the mixer pump and monitoring equipment; operation of the mixer pump, process monitoring equipment and caustic addition; the pump stand, caustic addition skid, the electrical skid, the video camera system and the two densitometers. Also covered is the removal and decontamination of the mixer pump and process monitoring system. Authority for this safety basis is WHC-IP-0842 (Waste Tank Administration). Section 15.9, Rev. 2 (Unreviewed Safety Questions) of WHC-IP-0842 requires that an evaluation be performed for all physical modifications

  9. Compact terahertz passive spectrometer with wideband superconductor-insulator-superconductor mixer.

    Science.gov (United States)

    Kikuchi, K; Kohjiro, S; Yamada, T; Shimizu, N; Wakatsuki, A

    2012-02-01

    We developed a compact terahertz (THz) spectrometer with a superconductor-insulator-superconductor (SIS) mixer, aiming to realize a portable and highly sensitive spectrometer to detect dangerous gases at disaster sites. The receiver cryostat which incorporates the SIS mixer and a small cryocooler except for a helium compressor has a weight of 27 kg and dimensions of 200 mm × 270 mm × 690 mm. In spite of the small cooling capacity of the cryocooler, the SIS mixer is successfully cooled lower than 4 K, and the temperature variation is suppressed for the sensitive measurement. By adopting a frequency sweeping system using photonic local oscillator, we demonstrated a spectroscopic measurement of CH(3)CN gas in 0.2-0.5 THz range.

  10. Development of novel micro swirl mixer for producing fine metal oxide nanoparticles by continuous supercritical hydrothermal method.

    Science.gov (United States)

    Kawasaki, Shin-ichiro; Sue, Kiwamu; Ookawara, Ryuto; Wakashima, Yuichiro; Suzuki, Akira

    2010-01-01

    Novel micro swirl mixers were developed to synthesize nanoparticles, and the effect of their mixing performance on the characteristics of the synthesized nanoparticles was determined. The results were compared with those obtained using simple T-shaped mixers under the same reaction conditions. The synthesis of NiO, whose characteristics depend on the mixing performance of the mixer, was chosen as a model reaction. Initial investigations highlighted that the average particle size decreased from 32 to 23 to 20 nm as the inner diameter of the swirl mixers was decreased from 3.2 mm (Swirl mixer, SM-3.2) to 0.8 mm (Micro swirl mixer, MSM-0.8) to 0.5 mm (Micro swirl mixer, MSM-0.5), respectively. On the other hand, a similar decrease in the average particle size from 34 to 20 nm was observed with a decrease in the inner diameter of the T-shaped mixers from 1.3 mm (Tee union, T-1.3) to 0.3 mm (Micro tee union, T-0.3), respectively. Further, narrow particle size distributions were observed with a decrease in the inner diameter of each mixer. Furthermore, a computational fluid dynamics (CFD) simulation indicated an excellent mixing mechanism, which contributed to the improvement in the heating rate and the formation of nanoparticles of smaller size with a narrow particle size distribution. The result presented here indicates that the micro swirl mixers produce high-quality metal oxide nanoparticles. The size of the obtained particles with improved size distributions was comparable to that of the particles obtained using the T-shaped mixers, although the inner diameter of the swirl mixers was larger. Therefore, preliminary evidence suggests that the swirl flow mixers have the ability to produce rapid and homogeneous fluid mixing, thus controlling the particle size.

  11. A niobiumnitride mixer with niobium tuning circuit

    International Nuclear Information System (INIS)

    Plathner, B.; Schicke, M.; Lehnert, T.; Gundlach, K.H.; Rothermel, H.; Aoyagi, M.; Takada, S.

    1996-01-01

    This letter reports a low noise submillimeter-wave mixer using NbN tunnel junctions integrated in Nb matching circuits. The double side band receiver noise temperature was 245 K at 345 GHz. Plasma conditions for NbN film deposition on quartz substrates at room temperature are created by using a second Nb target as a selective nitrogen pump. Electrodes for tunnel junctions with critical temperatures above 15 K and normal state resistivities in the range from 130 to 160 μΩcm were obtained. This permits integrating NbN junctions into normal metal or non-NbN superconducting matching circuits, which is of great interest for THz mixers. copyright 1996 American Institute of Physics

  12. The effects of arbitrary injection angle and flow conditions on venturi-jet mixer

    Directory of Open Access Journals (Sweden)

    Sundararaj S.

    2012-01-01

    Full Text Available This paper describes the effect of jet injection angle, cross flow Reynolds number and velocity ratio on entrainment and mixing of jet with incompressible cross flow in venturi-jet mixer. Five different jet injection angles 45o, 60o, 90o, 125o, 135o are tested to evaluate the entrainment of jet and mixing performances of the mixer. Tracer concentration along the downstream of the jet injection, cross flow velocity, jet velocity and pressure drop across the mixer are determined experimentally to characterize the mixing performance of the mixer. The experiments show that the performance of a venturi-jet-mixer substantially improves at high injection angle and can be augmented still by increasing velocity ratio. The jet deflects much and penetrates less in the cross flow as the cross flow Reynolds number is increased. The effect could contribute substantially to the better mixing index with moderate pressure drop. Normalized jet profile, concentration decay, jet velocity profile are computed from equations of conservation of mass, momentum and concentration written in natural co-ordinate systems. The comparison between the experimental and numerical results confirms the accuracy of the simulations. Correlations for jet trajectory and entrainment ratio of the mixer are obtained by multivariate-linear regression analysis using power law.

  13. On-line separation of iodine species in reactor water using mixer-settlers

    International Nuclear Information System (INIS)

    Malmbeck, R.; Skarnemark, G.

    1995-01-01

    A method for separation of iodine species from water has been developed. It is based on liquid-liquid extraction and separation is achieved in four extraction steps. A system based on this method for continuous separation of iodine species using mixer-settlers has been developed. It consists of four mixer-settler batteries with 4,4,6 and 6 mixer-settler stages each. As organic phase an aliphatic kerosene is used and the separation is improved if the organic solvent has been pretreated with iodine carrier, stripped and washed. With an aqueous feed flowrate of 10 ml/min and mixer-settler battery phase flowratios of approximately 0.1 except for the elementary iodine strip battery with a phase flowratio of 1, the system separation performance is 92% for methyl iodide, 97% for iodate and elementary iodine and 99% for iodide. (orig.)

  14. The cognitive profile of occipital lobe epilepsy and the selective association of left temporal lobe hypometabolism with verbal memory impairment.

    Science.gov (United States)

    Knopman, Alex A; Wong, Chong H; Stevenson, Richard J; Homewood, Judi; Mohamed, Armin; Somerville, Ernest; Eberl, Stefan; Wen, Lingfeng; Fulham, Michael; Bleasel, Andrew F

    2014-08-01

    We investigated the cognitive profile of structural occipital lobe epilepsy (OLE) and whether verbal memory impairment is selectively associated with left temporal lobe hypometabolism on [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET). Nine patients with OLE, ages 8-29 years, completed presurgical neuropsychological assessment. Composite measures were calculated for intelligence quotient (IQ), speed, attention, verbal memory, nonverbal memory, and executive functioning. In addition, the Wisconsin Card Sorting Test (WCST) was used as a specific measure of frontal lobe functioning. Presurgical FDG-PET was analyzed with statistical parametric mapping in 8 patients relative to 16 healthy volunteers. Mild impairments were evident for IQ, speed, attention, and executive functioning. Four patients demonstrated moderate or severe verbal memory impairment. Temporal lobe hypometabolism was found in seven of eight patients. Poorer verbal memory was associated with left temporal lobe hypometabolism (p = 0.002), which was stronger (p = 0.03 and p = 0.005, respectively) than the association of left temporal lobe hypometabolism with executive functioning or with performance on the WCST. OLE is associated with widespread cognitive comorbidity, suggesting cortical dysfunction beyond the occipital lobe. Verbal memory impairment is selectively associated with left temporal lobe hypometabolism in OLE, supporting a link between neuropsychological dysfunction and remote hypometabolism in focal epilepsy. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.

  15. Continuous mixer, process and use in a pumping plant for a high viscosity fluid

    Energy Technology Data Exchange (ETDEWEB)

    Cholet, H.

    1993-03-12

    The invention concerns a novel continuous mixer comprising a rotary shaft carrying two or more vanes for mixing two or more fluids of different viscosities supplied at the inlet of the mixer body and for providing, at the mixer body outlet, a mixture of viscosity lower than that of the more or most viscous fluid. Preferentially, the vane profile is such that, without fluid circulation, rotation of the vanes produces a reaction force parallel to the rotational axis and in the same direction as the resulting flow or does not produce a reaction force of significant magnitude parallel to the rotational axis. The mixer shaft is connected to a pump shaft which is rotated by hydraulic motor driven by pressurized fluid injection. The mixer is used especially for facilitating viscous crude oil pumping from directional wells including horizontal or inclined portions.

  16. The modeling of continuous mixers. Part I: The corotating twin-screw extruder

    NARCIS (Netherlands)

    Meijer, H.E.H.; Elemans, P.H.M.

    1988-01-01

    In many operations in polymer processing, such as polymer blending, devolatilization, or incorporation of fillers in a polymeric matrix, continuous mixers are used; e.g., corotating twin-screw extruders (ZSK), Buss Cokneaders and Farrel Continuous Mixers. Theoretical analysis of these machines tends

  17. The Strength Analysis of Differential Planetary Gears of Gearbox for Concrete Mixer Truck

    Science.gov (United States)

    Bae, M. H.; Bae, T. Y.; Kim, D. J.

    2018-03-01

    The power train of mixer gearbox for concrete mixer truck includes differential planetary gears to get large reduction ratio for operating mixer a drum and simple structure. The planetary gears are very important part of a mixer gearbox where strength problems namely gear bending stress, gear compressive stress and scoring failure are the main concern. In the present study, calculating specifications of the differential planetary gears and analyzing the gear bending and compressive stresses as well as scoring factor of the differential planetary gears gearbox for an optimal design of the mixer gearbox in respect to cost and reliability are investigated. The analyses of actual gear bending and compressive stresses of the differential planetary gears using Lewes & Hertz equation and verifications of the calculated specifications of the differential planetary gears evaluate the results with the data of allowable bending and compressive stress from the Stress-No. of cycles curves of gears. In addition, we also analyze actual gear scoring factor as well as evaluate the possibility of scoring failure of the differential planetary gear.

  18. Design of mixer settler extraction cycles II for recovery uranium from phosphoric acid

    International Nuclear Information System (INIS)

    Abdul Jami; Hafni Lissa Nuri

    2013-01-01

    Mixer settler is technically designed for extraction and separation process of uranium from phosphoric acid solution. Design calculation results shows that: the mixer settler consists of two parts: part of extraction process in the mixer tank and part of separation process in settler tank. The mixer tank type of box with 4 baffles, the size of mixer tank, 0.8 m width, 0.8 m length, 1 m high of liquid, 1.05 m high of mixer tank, stirrer type of disk 6 blade, and power of mixing 4 hp and the settler tank type of rectangular with size of settler tank, 0.8 m width 5 m length, 1 m high of liquid, 1.05 m high of settler tank. For uranium recovery efficiency up to 91%, extraction process is done in 3 stage counter current flow using a solvent Organic (O) DEHPA-TOPO in Kerosene at a phase of ratio A/O of 2:1. The aqueous enter through stage 3 and the organic solvent enter through stage 1. The process of settling occurred with the value of settling velocity is 0.000694 m/s, dispersion factor Ψ = 0.3638 and the light fraction as the dispersed phase and value of Reynolds number (NRE) = 3,438. Because of the Reynolds number is lower than 5,000, it indicates that the quality of the separation is very good. (author)

  19. Quantum noise in a terahertz hot electron bolometer mixer

    OpenAIRE

    Zhang, W.; Khosropanah, P.; Gao, J. R.; Kollberg, E. L.; Yngvesson, K. S.; Bansal, T.; Barends, R.; Klapwijk, T. M.

    2010-01-01

    We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The ?-factor (the quantum efficiency ...

  20. AZ-101 Mixer Pump Test Qualification Test Procedures (QTP)

    International Nuclear Information System (INIS)

    THOMAS, W.K.

    2000-01-01

    Describes the Qualification test procedure for the AZ-101 Mixer Pump Data Acquisition System (DAS). The purpose of this Qualification Test Procedure (QTP) is to confirm that the AZ-101 Mixer Pump System has been properly programmed and hardware configured correctly. This QTP will test the software setpoints for the alarms and also check the wiring configuration from the SIMcart to the HMI. An Acceptance Test Procedure (ATP), similar to this QTP will be performed to test field devices and connections from the field

  1. Design and Characterization of 1.8-3.2 THz Schottky-based Harmonic Mixers

    OpenAIRE

    Bulcha, BT; Hesler, JL; Drakinskiy, V; Stake, J; Valavanis, A; Dean, P; Li, LH; Barker, NS

    2016-01-01

    A room-temperature Schottky diode-based WM-86 (WR-0.34) harmonic mixer was developed to build high-resolution spectrometers, and multi-pixel receivers in the THz region for applications such as radio astronomy, plasma diagnostics, and remote sensing. The mixer consists of a quartz-based Local Oscillator (LO), Intermediate-Frequency (IF) circuits, and a GaAs-based beam-lead THz circuit with an integrated diode. Measurements of the harmonic mixer were performed using a 2 THz solid-state source ...

  2. Substrate Effects in Wideband SiGe HBT Mixer Circuits

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Vidkjær, Jens; Krozer, Viktor

    2005-01-01

    are also applied to predict short distance substrate coupling effects. Simulation results using extracted equivalent circuit models and substrate coupling networks are compared with experimental results obtained on a wideband mixer circuit implemented in a 0.35 μm, 60 GHz ft SiGe HBT BiCMOS process.......In this paper, the influence from substrate effects on the performance of wideband SiGe HBT mixer circuits is investigated. Equivalent circuit models including substrate networks are extracted from on-wafer test structures and compared with electromagnetic simulations. Electromagnetic simulations...

  3. 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF

    Science.gov (United States)

    Chattopadhyay, Goutam; Schlecht, Erich T.; Lee, Choonsup; Lin, Robert H.; Gill, John J.; Mehdi, Imran; Sin, Seth; Deal, William; Loi, Kwok K.; Nam, Peta; hide

    2012-01-01

    GaAs-based, sub-harmonically pumped Schottky diode mixers offer a number of advantages for array implementation in a heterodyne receiver system. Since the radio frequency (RF) and local oscillator (LO) signals are far apart, system design becomes much simpler. A proprietary planar GaAs Schottky diode process was developed that results in very low parasitic anodes that have cutoff frequencies in the tens of terahertz. This technology enables robust implementation of monolithic mixer and frequency multiplier circuits well into the terahertz frequency range. Using optical and e-beam lithography, and conventional epitaxial layer design with innovative usage of GaAs membranes and metal beam leads, high-performance terahertz circuits can be designed with high fidelity. All of these mixers use metal waveguide structures for housing. Metal machined structures for RF and LO coupling hamper these mixers to be integrated in multi-pixel heterodyne array receivers for spectroscopic and imaging applications. Moreover, the recent developments of terahertz transistors on InP substrate provide an opportunity, for the first time, to have integrated amplifiers followed by Schottky diode mixers in a heterodyne receiver at these frequencies. Since the amplifiers are developed on a planar architecture to facilitate multi-pixel array implementation, it is quite important to find alternative architecture to waveguide-based mixers.

  4. First Results of the Sideband-Separating Mixer for ALMA Band 9 Upgrade

    NARCIS (Netherlands)

    Khudchenko, Andrey; Hesper, Ronald; Baryshev, Andrey; Mena, F. Patricio; Gerlofma, Gerrit; Zijlstra, Tony; Klapwijk, Teun M.; Kooi, Jacob W.; Spaans, Marco

    2011-01-01

    Last year, the design and implementation details of a new modular sideband-separating mixer block, intended as an upgrade for the current single-ended ALMA Band 9 mixers, were presented at this conference. In high-frequency observation bands like ALMA Band 9 (600-720 GHz), which is strongly

  5. VAPOR MIXER FOR GELATINIZATION OF STARCH IN LIQUEFYING STATION

    Directory of Open Access Journals (Sweden)

    V. V. Ananskikh

    2015-01-01

    Full Text Available Starch hydrolysis is main technological process in production of starch sweeteners. Acid hydrolysis of starch using hydrochloric acid is carried out very fast but it does not allow to carry out full hydrolysis and to produce products with given carbohydrate composition. Bioconversion of starch allows to eliminate these limitations. At production of starch sweeteners from starch using enzymes starch hydrolysis is carried out in two stages At first starch – starch liquefaction the rapid increase of viscosity takes place which requires intensive mixing. Liquefying station consists of jet-cooker, holder, pressure regulator and evaporator. Jet-cooker of starch is its main part, starch is quickly turns into soluble (gelatinized state and it is partially liquefied by injection of starch suspension by flow of water vapor under pressure not less than 0,8 MPa. Heat and hydraulic calculation were carried out in order to determine constructive sizes of mixer for cooking of starch. The main hydraulic definable parameters are pressure drop in mixer, vapor pressure at mixer inlet, daily capacity of station by glucose syrup M, product consumption (starch suspension, diameter of inlet section of vapor nozzle. The goal of calculation was to determine vapor consumption M1, diameter d2 of outlet section of confuser injector, length l2 of gelatinization section. For heat calculation there was used Shukhov’s formula along with heat balance equation for gelatinization process. The numerical solution obtained with adopted assumptions given in applied mathematical package MATHCAD, for M = 50 t/day gives required daily vapor consumption M1 = 14,446 т. At hydraulic calculation of pressure drop in mixer there was used Bernoulli’s theorem. Solving obtained equations using MATHCAD found diameter of outlet section of consufer d2 = 0,023 м, vapor pressure inside of mixer p2 = 3,966·105 Па, l2 = 0,128 м. Developed method of calculation is used to determine

  6. RF Performance of a 600-720 GHz Sideband Separating Mixer with All-Copper Micromachined Waveguide Mixer Block

    NARCIS (Netherlands)

    Mena, F. P.; Kooi, J.; Baryshev, A. M.; Lodewijk, C. F. J.; Klapwijk, T. M.; Wild, W.; Desmaris, V.; Meledin, D.; Pavolotsky, A.; Belitsky, V.; Wild, Wolfgang

    2008-01-01

    Here we report on the RF performance of a 2SB mixer (600-720 GHz) fabricated in a new method that combines traditional micromachining with waveguide components fabricated by photolithography and electroplating. The latter allows reaching, in a reproducible way, the stringent accuracies necessary for

  7. Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Kuwahara, D., E-mail: dkuwahar@cc.tuat.ac.jp [Department of Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); Ito, N. [Department of Intelligent System Engineering, Ube National College of Technology, Ube, Yamaguchi 755-8555 (Japan); Nagayama, Y. [Department of Helical Plasma Research, National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Yoshinaga, T. [Department of Applied Physics, National Defense Academy, Yokosuka, Kanagawa 239-0811 (Japan); Yamaguchi, S. [Department of Pure and Applied Physics, Kansai University, Suita, Osaka 564-8680 (Japan); Yoshikawa, M.; Kohagura, J. [Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Sugito, S. [Equipment Development Center, Institute for Molecular Science, Okazaki, Aichi 444-8585 (Japan); Kogi, Y. [Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka, Fukuoka 811-0295 (Japan); Mase, A. [Art, Science and Technology Center for Cooperative Research, Kyusyu University, Kasuga, Fukuoka 816-8580 (Japan)

    2014-11-15

    A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

  8. A Formal Model of Identity Mixer

    DEFF Research Database (Denmark)

    Camenisch, Jan; Mödersheim, Sebastian Alexander; Sommer, Dieter

    2010-01-01

    Identity Mixer is an anonymous credential system developed at IBM that allows users for instance to prove that they are over 18 years old without revealing their name or birthdate. This privacy-friendly tech- nology is realized using zero-knowledge proofs. We describe a formal model of Identity...

  9. Submersible canned motor mixer pump

    International Nuclear Information System (INIS)

    Guardiani, R.F.; Pollick, R.D.

    1997-01-01

    A mixer pump is described used in a waste tank for mobilizing high-level radioactive liquid waste having a column assembly containing power cables, a motor housing with electric motor means which includes a stator can of a stator assembly and a rotor can of a rotor assembly, and an impeller assembly with an impeller connected to a shaft of the rotor assembly. The column assembly locates the motor housing with the electric motor means adjacent to the impeller which creates an hydraulic head, and which forces the liquid waste into the motor housing to cool the electric motor means and to lubricate radial and thrust bearing assemblies. Hard-on-hard bearing surfaces of the bearing assemblies and a ring assembly between the impeller and electric motor means act to grind down large particles in the liquid waste flow. These larger particles are received in slots in the static bearing members of the radial bearing assemblies. Only solid waste particles smaller than the clearances in the system can pass there through, thereby resisting damage to and the interruption of the operation of the mixer pump. 10 figs

  10. Modeling on the kinetics of an EPDM devulcanization in an internal batch mixer using an amine as the devulcanizing agent

    NARCIS (Netherlands)

    Sutanto, P.; Laksmana, F. L.; Picchioni, E.; Janssen, L. P. B. M.; Picchioni, F.

    2006-01-01

    The use of amines and the application of mechanical force (shear) in rubber devulcanization have been reported in the literatures. In this paper, the devulcanization of ethylene propylene diene rubber (EPDM) is conducted in a Brabender batch mixer using hexadecylarnine (HDA) as the devulcanizing

  11. Deviations from mass transfer equilibrium and mathematical modeling of mixer-settler contactors

    International Nuclear Information System (INIS)

    Beyerlein, A.L.; Geldard, J.F.; Chung, H.F.; Bennett, J.E.

    1980-01-01

    This paper presents the mathematical basis for the computer model PUBG of mixer-settler contactors which accounts for deviations from mass transfer equilibrium. This is accomplished by formulating the mass balance equations for the mixers such that the mass transfer rate of nuclear materials between the aqueous and organic phases is accounted for. 19 refs

  12. AlGaAs/GaAs quasi-bulk effect mixers: Analysis and experiments

    Science.gov (United States)

    Yngvesson, K. S.; Yang, J.-X.; Agahi, F.; Dai, D.; Musante, C.; Grammer, W.; Lau, K. M.

    1992-01-01

    The lowest noise temperature for any receiver in the 0.5 to 1 THz range has been achieved with the bulk InSb hot electron mixer, which unfortunately suffers from the problem of having a very narrow bandwidth (1-2 MHz). We have demonstrated a three order of magnitude improvement in the bandwidth of hot electron mixers, by using the two-dimensional electron gas (2DEG) medium at the hetero-interface between AlGaAs and GaAs. We have tested both inhouse MOCVD-grown material, and MBE materials, with similar results. The conversion loss (L(sub c)) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that L(sub c) can be decreased to about 10 dB in future devices. Calculated and measured curves of L(sub c), versus PLO and IDC, respectively, agree well. We argue that there are several different configurations of hot electron mixers, which will also show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.

  13. MICROFLUIDIC MIXERS FOR THE INVESTIGATION OF PROTEIN FOLDING USING SYNCHROTRON RADIATION CIRCULAR DICHROISM SPECTROSCOPY

    International Nuclear Information System (INIS)

    Kane, A; Hertzog, D; Baumgartel, P; Lengefeld, J; Horsley, D; Schuler, B; Bakajin, O

    2006-01-01

    The purpose of this study is to design, fabricate and optimize microfluidic mixers to investigate the kinetics of protein secondary structure formation with Synchrotron Radiation Circular Dichroism (SRCD) spectroscopy. The mixers are designed to rapidly initiate protein folding reaction through the dilution of denaturant. The devices are fabricated out of fused silica, so that they are transparent in the UV. We present characterization of mixing in the fabricated devices, as well as the initial SRCD data on proteins inside the mixers

  14. Effect of Processing Variables on Tensile Modulus and Morphology of Polyethylene/Clay Nanocomposites Prepared in an Internal Mixer

    Science.gov (United States)

    Ujianto, O.; Jollands, M.; Kao, N.

    2018-03-01

    A comparative study on effect of internal mixer on high density Polyethylene (HDPE)/clay nanocomposites preparation was done. Effect of temperature, rotor rotation (rpm), and mixing time, as well as rotor type (Roller and Banbury) on mechanical properties and morphology of HDPE/clay nanocomposites were studied using Box-Behnken experimental design. The model was developed according to secant modulus and confirmed to morphology analysis using Transmission Electron Microscopy (TEM). The finding suggests that there is different mechanisms occurred in each rotor to improve the mechanical properties. The mechanism in Roller is medium shear and medium diffusion, while Banbury is high shear and low diffusion. The difference in mechanism to disperse the clay particles attribute to the different optimum processing conditions in each rotor. The settings for roller samples are predicted around mid temperature, mid speed, and mid mixing time. There is no optimum setting for Banbury within the processing boundaries. The best settings for Banbury are at low, high, low settings. The morphology results showed a hybrid composite structure, with some exfoliations and some intercalations. There was a correlation between better mechanical properties and morphology with more exfoliation and thinner intercalated particles.

  15. A compact D-band monolithic APDP-based sub-harmonic mixer

    Science.gov (United States)

    Zhang, Shengzhou; Sun, Lingling; Wang, Xiang; Wen, Jincai; Liu, Jun

    2017-11-01

    The paper presents a compact D-band monolithic sub-harmonic mixer (SHM) with 3 μm planar hyperabrupt schottky-varactor diodes offered by 70 nm GaAs mHEMT technology. According to empirical equivalent-circuit models, a wide-band large signal equivalent circuit model of the diode is proposed. Based on the extracted model, the mixer is implemented and optimized with a shunt-mounted anti-parallel diode pair (APDP) to fulfill the sub-harmonic mixing mechanism. Furthermore, a modified asymmetric three-transmission-line coupler is devised to achieve high-level coupling and minimize the chip size. The measured results show that the conversion gain varies between -13.9 dB and -17.5 dB from 110 GHz to 145 GHz, with a local oscillator (LO) power level of 14 dBm and an intermediate frequency (IF) of 1 GHz. The total chip size including probe GSG pads is 0.57 × 0.68mm2. In conclusion, the mixer exhibits outstanding figure-of-merits.

  16. Frontal lobe function in temporal lobe epilepsy

    Science.gov (United States)

    Stretton, J.; Thompson, P.J.

    2012-01-01

    Summary Temporal lobe epilepsy (TLE) is typically associated with long-term memory dysfunction. The frontal lobes support high-level cognition comprising executive skills and working memory that is vital for daily life functioning. Deficits in these functions have been increasingly reported in TLE. Evidence from both the neuropsychological and neuroimaging literature suggests both executive function and working memory are compromised in the presence of TLE. In relation to executive impairment, particular focus has been paid to set shifting as measured by the Wisconsin Card Sorting Task. Other discrete executive functions such as decision-making and theory of mind also appear vulnerable but have received little attention. With regard to working memory, the medial temporal lobe structures appear have a more critical role, but with emerging evidence of hippocampal dependent and independent processes. The relative role of underlying pathology and seizure spread is likely to have considerable bearing upon the cognitive phenotype and trajectory in TLE. The identification of the nature of frontal lobe dysfunction in TLE thus has important clinical implications for prognosis and surgical management. Longitudinal neuropsychological and neuroimaging studies assessing frontal lobe function in TLE patients pre- and postoperatively will improve our understanding further. PMID:22100147

  17. Extraction of indium from sulphate solutions with D2EHPA solutions using static mixers

    International Nuclear Information System (INIS)

    Nacevski, N.; Poposka, F.; Nikov, B.

    1995-01-01

    The possible use of static mixers as a reactor for the extraction of indium from sulphate solutions was investigated. The experimental work was focused on ''Kenics'' type static mixers, since these were found simplest and cheapest among a variety of models, and yet yielded acceptable preliminary results with low pressure drop along the reactor. A series of experiments was carried out in a stirred continuous flow reactor to compare the results. It was found that under certain (different) conditions both reactors perform satisfactorily. The energy consumption of a static mixer is of the same order of magnitude as that of a stirred vessel. The most significant achievement of the experimental work is establishing that the residence time in a static mixer is about two orders of magnitude less than that in a stirred reactor. (orig.)

  18. Mixer pump test plan for double-shell tank AZ-101. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Symons, G.A.

    1996-02-01

    Westinghouse Hanford Company has undertaken the task to develop and demonstrate a method of retrieval for double-shell tank waste. Mixer pumps were chosen as the planned method of retrieval for DSTs, based on engineering technology studies, past experience with hydraulic sluicing at the Hanford Site, and experience with mixer pumps at the Westinghouse Savannah River Site.

  19. Mixer pump test plan for double-shell tank AZ-101. Revision 1

    International Nuclear Information System (INIS)

    Symons, G.A.

    1996-02-01

    Westinghouse Hanford Company has undertaken the task to develop and demonstrate a method of retrieval for double-shell tank waste. Mixer pumps were chosen as the planned method of retrieval for DSTs, based on engineering technology studies, past experience with hydraulic sluicing at the Hanford Site, and experience with mixer pumps at the Westinghouse Savannah River Site

  20. A wideband current-commutating passive mixer for multi-standard receivers in a 0.18 μm CMOS

    International Nuclear Information System (INIS)

    Bao Kuan; Fan Xiangning; Li Wei; Wang Zhigong

    2013-01-01

    This paper reports a wideband passive mixer for direct conversion multi-standard receivers. A brief comparison between current-commutating passive mixers and active mixers is presented. The effect of source and load impedance on the linearity of a mixer is analyzed. Specially, the impact of the input impedance of the transimpedance amplifier (TIA), which acts as the load impedance of a mixer, is investigated in detail. The analysis is verified by a passive mixer implemented with 0.18 μm CMOS technology. The circuit is inductorless and can operate over a broad frequency range. On wafer measurements show that, with radio frequency (RF) ranges from 700 MHz to 2.3 GHz, the mixer achieves 21 dB of conversion voltage gain with a −1 dB intermediate frequency (IF) bandwidth of 10 MHz. The measured IIP3 is 9 dBm and the measured double-sideband noise figure (NF) is 10.6 dB at 10 MHz output. The chip occupies an area of 0.19 mm 2 and drains a current of 5.5 mA from a 1.8 V supply. (semiconductor integrated circuits)

  1. Study on hydrodynamics and mass transfer of the critically safe multistage mixer-settler

    International Nuclear Information System (INIS)

    Zhang Weibo; Jiao Rongzhou; Liu Bingren

    1992-08-01

    The study on structure of critically safe multistage mixer-settler for the extraction process of high enriched uranium and plutonium has been completed. The mixer-settler has simple structure, good critical safety, flexibility in operation (O/A from 0.5 to 5) and high extraction efficiency (E x > 90%). These performances have been proved in the hydrodynamics and mass transfer experiments at a three stages cascade mixer-settler. Based on the others experience, a trapezoidal impeller combined with half-open turbine is developed which has stronger pumping and well mixing function at low rotating speed. The optimal rotating speed is 250 to 280 r/min obtained by experiments

  2. Study on installation of the submersible mixer

    International Nuclear Information System (INIS)

    Tian, F; Shi, W D; He, X H; Xu, Y H; Jiang, H

    2013-01-01

    Study on installation of the submersible mixer for sewage treatment has been limited. In this article, large-scale computational fluid dynamics software FLUENT6.3 was adopted. ICEM software was used to build an unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. Agitation pools on four different installation location cases were simulated respectively, and the external characteristic of the submersible mixer and the velocity cloud of the axial section were respectively comparatively analyzed. The best stirring effect can be reached by the installation location of case C, which is near the bottom of the pool 600 mm and blade distance the bottom at least for 200 mm wide and wide edge and narrow edge distance by 4:3. The conclusion can guide the engineering practice

  3. Design of a mixer for the thrust-vectoring system on the high-alpha research vehicle

    Science.gov (United States)

    Pahle, Joseph W.; Bundick, W. Thomas; Yeager, Jessie C.; Beissner, Fred L., Jr.

    1996-01-01

    One of the advanced control concepts being investigated on the High-Alpha Research Vehicle (HARV) is multi-axis thrust vectoring using an experimental thrust-vectoring (TV) system consisting of three hydraulically actuated vanes per engine. A mixer is used to translate the pitch-, roll-, and yaw-TV commands into the appropriate TV-vane commands for distribution to the vane actuators. A computer-aided optimization process was developed to perform the inversion of the thrust-vectoring effectiveness data for use by the mixer in performing this command translation. Using this process a new mixer was designed for the HARV and evaluated in simulation and flight. An important element of the Mixer is the priority logic, which determines priority among the pitch-, roll-, and yaw-TV commands.

  4. A Passive X-Band Double Balanced Mixer Utilizing Diode Connected SiGe HBTs

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus Schandorph; Johansen, Tom Keinicke; Tamborg, Kjeld

    2013-01-01

    In this paper, a passive double balanced mixer in SiGe HBT technology is presented. Due to lack of suitable passive mixing elements in the technology, the mixing elements are formed by diode connected HBTs. The mixer is optimized for use in doppler radars and is highly linear with 1 dB compressio...

  5. Heat transfer and the continuous production of hydroxypropyl starch in a static mixer reactor

    NARCIS (Netherlands)

    Lammers, Gerard; Beenackers, Antonie A. C. M.

    1994-01-01

    A novel continuous reactor for the chemical derivation of aqueous starch solutions based on static mixers is proposed. Both the experimentally observed axial and radial temperature gradients in the static mixer could be accurately described by a pseudohomogeneous two-dimensional heat transfer (PTHT)

  6. A general numerical analysis program for the superconducting quasiparticle mixer

    Science.gov (United States)

    Hicks, R. G.; Feldman, M. J.; Kerr, A. R.

    1986-01-01

    A user-oriented computer program SISCAP (SIS Computer Analysis Program) for analyzing SIS mixers is described. The program allows arbitrary impedance terminations to be specified at all LO harmonics and sideband frequencies. It is therefore able to treat a much more general class of SIS mixers than the widely used three-frequency analysis, for which the harmonics are assumed to be short-circuited. An additional program, GETCHI, provides the necessary input data to program SISCAP. The SISCAP program performs a nonlinear analysis to determine the SIS junction voltage waveform produced by the local oscillator. The quantum theory of mixing is used in its most general form, treating the large signal properties of the mixer in the time domain. A small signal linear analysis is then used to find the conversion loss and port impedances. The noise analysis includes thermal noise from the termination resistances and shot noise from the periodic LO current. Quantum noise is not considered. Many aspects of the program have been adequately verified and found accurate.

  7. Emphysema lung lobe volume reduction: effects on the ipsilateral and contralateral lobes

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Kim, Hyun J.; Abtin, Fereidoun G.; Galperin-Aizenberg, Maya; Pais, Richard; Da Costa, Irene G.; Ordookhani, Arash; Chong, Daniel; Ni, Chiayi; McNitt-Gray, Michael F.; Goldin, Jonathan G. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States); Strange, Charlie [Medical University of South Carolina, Department of Pulmonary and Critical Care Medicine, Columbia, SC (United States); Tashkin, Donald P. [David Geffen School of Medicine at UCLA, Division of Pulmonary and Critical Care Medicine, Los Angeles, CA (United States)

    2012-07-15

    To investigate volumetric and density changes in the ipsilateral and contralateral lobes following volume reduction of an emphysematous target lobe. The study included 289 subjects with heterogeneous emphysema, who underwent bronchoscopic volume reduction of the most diseased lobe with endobronchial valves and 132 untreated controls. Lobar volume and low-attenuation relative area (RA) changes post-procedure were measured from computed tomography images. Regression analysis (Spearman's rho) was performed to test the association between change in the target lobe volume and changes in volume and density variables in the other lobes. The target lobe volume at full inspiration in the treatment group had a mean reduction of -0.45 L (SE = 0.034, P < 0.0001), and was associated with volume increases in the ipsilateral lobe (rho = -0.68, P < 0.0001) and contralateral lung (rho = -0.16, P = 0.006), and overall reductions in expiratory RA (rho = 0.31, P < 0.0001) and residual volume (RV)/total lung capacity (TLC) (rho = 0.13, P = 0.03). When the volume of an emphysematous target lobe is reduced, the volume is redistributed primarily to the ipsilateral lobe, with an overall reduction. Image-based changes in lobar volumes and densities indicate that target lobe volume reduction is associated with statistically significant overall reductions in air trapping, consistent with expansion of the healthier lung. (orig.)

  8. Emphysema lung lobe volume reduction: effects on the ipsilateral and contralateral lobes

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Kim, Hyun J.; Abtin, Fereidoun G.; Galperin-Aizenberg, Maya; Pais, Richard; Da Costa, Irene G.; Ordookhani, Arash; Chong, Daniel; Ni, Chiayi; McNitt-Gray, Michael F.; Goldin, Jonathan G.; Strange, Charlie; Tashkin, Donald P.

    2012-01-01

    To investigate volumetric and density changes in the ipsilateral and contralateral lobes following volume reduction of an emphysematous target lobe. The study included 289 subjects with heterogeneous emphysema, who underwent bronchoscopic volume reduction of the most diseased lobe with endobronchial valves and 132 untreated controls. Lobar volume and low-attenuation relative area (RA) changes post-procedure were measured from computed tomography images. Regression analysis (Spearman's rho) was performed to test the association between change in the target lobe volume and changes in volume and density variables in the other lobes. The target lobe volume at full inspiration in the treatment group had a mean reduction of -0.45 L (SE = 0.034, P < 0.0001), and was associated with volume increases in the ipsilateral lobe (rho = -0.68, P < 0.0001) and contralateral lung (rho = -0.16, P = 0.006), and overall reductions in expiratory RA (rho = 0.31, P < 0.0001) and residual volume (RV)/total lung capacity (TLC) (rho = 0.13, P = 0.03). When the volume of an emphysematous target lobe is reduced, the volume is redistributed primarily to the ipsilateral lobe, with an overall reduction. Image-based changes in lobar volumes and densities indicate that target lobe volume reduction is associated with statistically significant overall reductions in air trapping, consistent with expansion of the healthier lung. (orig.)

  9. A Wideband Balun LNA I/Q-Mixer combination in 65nm CMOS

    NARCIS (Netherlands)

    Blaakmeer, S.C.; Klumperink, Eric A.M.; Leenaerts, D.M.W.; Nauta, Bram

    2008-01-01

    An inductor-less LNA-mixer topology merges an I/Q current-commutating mixer with a noise-canceling balun/LNA. The topology achieves >18dB conversion gain, a flat NF<5.5dB, IIP2=+20dBm and IIP3=-3dBm from 500MHz to 7GHz. The core circuit consumes 16mW and occupies less than 0.01mm2 in 65nm CMOS.

  10. Flow optimisation of a biomass mixer; Stroemungstechnische Optimierung eines Biomasse-Ruehrwerks

    Energy Technology Data Exchange (ETDEWEB)

    Casartelli, E.; Waser, R. [Hochschule fuer Technik und Architektur Luzern (HTA), Horw (Switzerland); Fankhauser, H. [Fankhauser Maschinenfabrik, Malters (Switzerland)

    2007-03-15

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) reports on the optimisation of a mixing system used in biomass reactors. Aim of this work was to improve the fluid dynamic qualities of the mixer in order to increase its efficiency while, at the same time, maintaining robustness and low price. Investigative work performed with CFD (Computational Fluid Dynamics) is reported on. CFD is quoted by the authors as being very effective in solving such optimisation problems as it is suited to flows that are not easily accessible for analysis. Experiments were performed on a fermenter / mixer model in order to confirm the computational findings. The results obtained with two and three-dimensional simulations are presented and discussed, as are those resulting from the tests with the 1:10 scale model of a digester. Initial tests with the newly developed mixer-propellers in a real-life biogas installation are reported on and further tests to be made are listed.

  11. An ultra-broadband distributed passive gate-pumped mixer in 0.18 μm CMOS

    International Nuclear Information System (INIS)

    Yu Zhenxing; Feng Jun

    2013-01-01

    A broadband distributed passive gate-pumped mixer (DPGM) using standard 0.18 μm CMOS technology is presented. By employing distributed topology, the mixer can operate at a wide frequency range. In addition, a fourth-order low pass filter is applied to improve the port-to-port isolation. This paper also analyzes the impedance match and conversion loss of the mixer, which consumes zero dc power and exhibits a measured conversion loss of 9.4–17 dB from 3 to 40 GHz with a compact size of 0.78 mm 2 . The input referred 1 dB compression point is higher than 4 dBm at a fixed IF frequency of 500 MHz and RF frequency of 23 GHz, and the measured RF-to-LO, RF-to-IF and LO-to-IF isolations are better than 21, 38 and 45 dB, respectively. The mixer is suitable for WLAN, UWB, Wi-Max, automotive radar systems and other millimeter-wave radio applications. (semiconductor integrated circuits)

  12. Sideband Separating Mixer for 600-720 GHz

    NARCIS (Netherlands)

    Khudchenko, Andrey; Hesper, Ronald; Barychev, Andrey; Gerlofma, Gerrit; Mena, Patricio; Zijlstra, Tony; Klapwijk, Teun; Spaans, Marco; Kooi, Jacob W.; Zhang, C; Zhang, XC; Siegel, PH; He, L; Shi, SC

    2010-01-01

    The ALMA Band 9 receiver cartridge (600-720 GHz) based on Dual Sideband (DSB) superconductor-insulator-superconductor (SIS) mixer is currently in full production. In the case of spectral line observations, the integration time to reach a certain signal-to-noise level can be reduced by about a factor

  13. Phase locking of a 3.4 THz third-order distributed feedback quantum cascade laser using a room-temperature superlattice harmonic mixer

    NARCIS (Netherlands)

    Hayton, D. J.; Khudchencko, A.; Pavelyev, D. G.; Hovenier, J. N.; Baryshev, A.; Gao, J. R.; Kao, T. Y.; Hu, Q.; Reno, J. L.; Vaks, V.

    2013-01-01

    We report on the phase locking of a 3.4 THz third-order distributed feedback quantum cascade laser (QCL) using a room temperature GaAs/AlAs superlattice diode as both a frequency multiplier and an internal harmonic mixer. A signal-to-noise level of 60 dB is observed in the intermediate frequency

  14. Phase locking of a 3.4 THz third-order distributed feedback quantum cascade laser using a room-temperature superlattice harmonic mixer

    NARCIS (Netherlands)

    Hayton, D.J.; Khudchenko, A.; Pavelyev, D.G.; Hovenier, J.N.; Baryshev, A.; Gao, J.R.; Kao, T.Y.; Hu, Q.; Reno, J.L.; Vaks, V.

    2013-01-01

    We report on the phase locking of a 3.4 THz third-order distributed feedback quantum cascade laser (QCL) using a room temperature GaAs/AlAs superlattice diode as both a frequency multiplier and an internal harmonic mixer. A signal-to-noise level of 60?dB is observed in the intermediate frequency

  15. Criticality calculation method for mixer-settlers

    International Nuclear Information System (INIS)

    Gonda, Kozo; Aoyagi, Haruki; Nakano, Ko; Kamikawa, Hiroshi.

    1980-01-01

    A new criticality calculation code MACPEX has been developed to evaluate and manage the criticality of the process in the extractor of mixer-settler type. MACPEX can perform the combined calculation with the PUREX process calculation code MIXSET, to get the neutron flux and the effective multiplication constant in the mixer-settlers. MACPEX solves one-dimensional diffusion equation by the explicit difference method and the standard source-iteration technique. The characteristics of MACPEX are as follows. 1) Group constants of 4 energy groups for the 239 Pu-H 2 O solution, water, polyethylene and SUS 28 are provided. 2) The group constants of the 239 Pu-H 2 O solution are given by the functional formulae of the plutonium concentration, which is less than 50 g/l. 3) Two boundary conditions of the vacuum condition and the reflective condition are available in this code. 4) The geometrical bucklings can be calculated for a certain energy group and/or region by using the three dimentional neutron flux profiles obtained by CITATION. 5) The buckling correction search can be carried out in order to get a desired k sub(eff). (author)

  16. An X-band Schottky diode mixer in SiGe technology with tunable Marchand balun

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus Schandorph; Johansen, Tom Keinicke; Tamborg, Kjeld M.

    2017-01-01

    In this paper, we propose a double balanced mixer with a tunable Marchand balun. The circuit is designed in a SiGe BiCMOS process using Schottky diodes. The tunability of the Marchand balun is used to enhance critical parameters for double balanced mixers. The local oscillator-IF isolation can...

  17. Submillisecond mixing in a continuous-flow, microfluidic mixer utilizing mid-infrared hyperspectral imaging detection.

    Science.gov (United States)

    Kise, Drew P; Magana, Donny; Reddish, Michael J; Dyer, R Brian

    2014-02-07

    We report a continuous-flow, microfluidic mixer utilizing mid-infrared hyperspectral imaging detection, with an experimentally determined, submillisecond mixing time. The simple and robust mixer design has the microfluidic channels cut through a polymer spacer that is sandwiched between two IR transparent windows. The mixer hydrodynamically focuses the sample stream with two side flow channels, squeezing it into a thin jet and initiating mixing through diffusion and advection. The detection system generates a mid-infrared hyperspectral absorbance image of the microfluidic sample stream. Calibration of the hyperspectral image yields the mid-IR absorbance spectrum of the sample versus time. A mixing time of 269 μs was measured for a pD jump from 3.2 to above 4.5 in a D2O sample solution of adenosine monophosphate (AMP), which acts as an infrared pD indicator. The mixer was further characterized by comparing experimental results with a simulation of the mixing of an H2O sample stream with a D2O sheath flow, showing good agreement between the two. The IR microfluidic mixer eliminates the need for fluorescence labeling of proteins with bulky, interfering dyes, because it uses the intrinsic IR absorbance of the molecules of interest, and the structural specificity of IR spectroscopy to follow specific chemical changes such as the protonation state of AMP.

  18. Numerical and Experimental Study on Mixing Performances of Simple and Vortex Micro T-Mixers

    Directory of Open Access Journals (Sweden)

    Mubashshir Ahmad Ansari

    2018-04-01

    Full Text Available Vortex flow increases the interface area of fluid streams by stretching along with providing continuous stirring action to the fluids in micromixers. In this study, experimental and numerical analyses on a design of micromixer that creates vortex flow were carried out, and the mixing performance was compared with a simple micro T-mixer. In the vortex micro T-mixer, the height of the inlet channels is half of the height of the main mixing channel. The inlet channel connects to the main mixing channel (micromixer at the one end at an offset position in a fashion that creates vortex flow. In the simple micro T-mixer, the height of the inlet channels is equal to the height of the channel after connection (main mixing channel. Mixing of fluids and flow field have been analyzed for Reynolds numbers in a range from 1–80. The study has been further extended to planar serpentine microchannels, which were combined with a simple and a vortex T-junction, to evaluate and verify their mixing performances. The mixing performance of the vortex T-mixer is higher than the simple T-mixer and significantly increases with the Reynolds number. The design is promising for efficiently increasing mixing simply at the T-junction and can be applied to all micromixers.

  19. Influence of gas inlet angle on the mixing process in a Venturi mixer

    Directory of Open Access Journals (Sweden)

    Romańczyk Mathias

    2017-01-01

    Full Text Available In this paper numerical analysis were performed to investigate the influence of gas inlet angle on mixing process in a Venturi mixer. Performance of an industrial gas engine depends significantly on the quality of mixing air and fuel; therefore, on the homogeneity of the mixture. In addition, there must be a suitable, adapted to the current load of fuel, air ratio. Responsible for this fact, among others, is the mixer located before entering the combustion chamber of the engine. Incorrect mixture proportion can lead to unstable operation of the engine, as well as higher emissions going beyond current environmental standards in the European Union. To validate the simulation the Air-Fuel Ratio (AFR was mathematically calculated for the air-fuel mixture of lean combustion gas engine. In this study, an open source three-dimensional computational fluid dynamics (CFD modelling software OpenFOAM has been used, to investigate and analyse the influence of different gas inlet angles on mixer characteristics and their performances. Attention was focused on the air-fuel ratio changes, pressure loss, as well as improvement of the mixing quality in the Venturi mixer.

  20. A Curious Lobe

    Directory of Open Access Journals (Sweden)

    Andréa Chabot-Naud

    2011-01-01

    Full Text Available A case of azygos lobe is presented. An azygos lobe is an accessory lobe of the lung that may occasionally be confused with a pathological process such as a bulla, lung abscess or neoplasm. Its pathogenesis is discussed, as are the characteristic x-ray features that enable an accurate diagnosis.

  1. Packaging design criteria, transfer and disposal of 102-AP mixer pump

    International Nuclear Information System (INIS)

    Carlstrom, R.F.

    1994-01-01

    A mixer pump installed in storage tank 241-AP-102 (102-AP) has failed. This pump is referred to as the 102-AP mixer pump (APMP). The APMP will be removed from 102-AP 1 and a new pump will be installed. The main purpose of the Packaging Design Criteria (PDC) is to establish criteria necessary to design and fabricate a shipping container for the transfer and storage of the APMP from 102-AP. The PDC will be used as a guide to develop a Safety Evaluation for Packaging (SEP)

  2. Noise and conversion performance of a high-Tc superconducting Josephson junction mixer at 0.6 THz

    Science.gov (United States)

    Gao, Xiang; Du, Jia; Zhang, Ting; Guo, Yingjie Jay

    2017-11-01

    This letter presents both theoretical and experimental investigations on the noise and conversion performance of a high-Tc superconducting (HTS) step-edge Josephson-junction mixer at the frequency of 0.6 THz and operating temperatures of 20-40 K. Based on the Y-factor and U-factor methods, a double-sideband noise temperature of around 1000 K and a conversion gain of -3.5 dB were experimentally obtained at 20 K. At the temperature of 40 K, the measured mixer noise and conversion efficiency are around 2100 K and -10 dB, respectively. The experimental data are in good agreement with the numerical analysis results using the three-port model. A detailed performance comparison with other reported HTS terahertz mixers has confirmed the superior performance of our presented mixer device.

  3. Flux intensification during microfiltration of distillery stillage using a kenics static mixer

    Directory of Open Access Journals (Sweden)

    Vasić Vesna M.

    2017-01-01

    Full Text Available The present work studies the effect of operating parameters (pH, feed flow rate, and transmembrane pressure on microfiltration of distillery stillage. Experiments were conducted in the presence of a Kenics static mixer as a turbulence promoter, and its influence on the flux improvement and specific energy consumption was examined. Response surface methodology was used to investigate the effect of selected factors on microfiltration performances. The results showed that response surface methodology is an appropriate model for mathematical presentation of the process. It was found that the use of a static mixer is justified at the feed flow rates higher than 100 L/h. In contrast, the use of a static mixer at low values of feed flow rate and transmembrane pressure has no justification from an economic point of view. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR 31002

  4. Drug residues recovered in feed after various feedlot mixer truck cleanout procedures.

    Science.gov (United States)

    Van Donkersgoed, Joyce; Sit, Dan; Gibbons, Nicole; Ramogida, Caterina; Hendrick, Steve

    2010-01-01

    A study was conducted to determine the effectiveness of two methods of equipment cleanout, sequencing or flushing, for reducing drug carryover in feedlot mixer trucks. Feed samples were collected from total mixed rations before and after various feed mixer equipment cleanout procedures. Medicated rations contained either 11 ppm of tylosin or 166 or 331 ppm of chlortetracycline. There were no differences between sequencing and flushing or between flushing with dry barley and flushing with barley silage in the median proportion of drug recovered in the next ration. A larger drug reduction was achieved using flush material at a volume of 10 versus 5% of the mixer capacity and mixing the flush material for 3 versus 4 min. Regardless of the drug or prescription concentrations in the total mixed rations or the equipment cleanout procedure used, concentrations of chlortetracycline and tylosin recovered were very low.

  5. High-k Scattering Receiver Mixer Performance for NSTX-U

    Science.gov (United States)

    Barchfeld, Robert; Riemenschneider, Paul; Domier, Calvin; Luhmann, Neville; Ren, Yang; Kaita, Robert

    2016-10-01

    The High-k Scattering system detects primarily electron-scale turbulence k θ spectra for studying electron thermal transport in NSTX-U. A 100 mW, 693 GHz probe beam passes through plasma, and scattered power is detected by a 4-pixel quasi optical, mixer array. Remotely controlled receiving optics allows the scattering volume to be located from core to edge with a k θ span of 7 to 40 cm-1. The receiver array features 4 RF diagonal input horns, where the electric field polarization is aligned along the diagonal of a square cross section horn, at 30 mm channel spacing. The local oscillator is provided by a 14.4 GHz source followed by a x48 multiplier chain, giving an intermediate frequency of 1 GHz. The receiver optics receive 4 discreet scattering angles simultaneously, and then focus the signals as 4 parallel signals to their respective horns. A combination of a steerable probe beam, and translating receiver, allows for upward or downward scattering which together can provide information about 2D turbulence wavenumber spectrum. IF signals are digitized and stored for later computer analysis. The performance of the receiver mixers is discussed, along with optical design features to enhance the tuning and performance of the mixers. Work supported in part by U.S. DOE Grant DE-FG02-99ER54518 and DE-AC02-09CH1146.

  6. Fuel Continuous Mixer ? an Approach Solution to Use Straight Vegetable Oil for Marine Diesel Engines

    Directory of Open Access Journals (Sweden)

    Đặng Van Uy

    2018-03-01

    Full Text Available The vegetable oil is well known as green fuel for diesel engines due to its low sunphur content and renewable stock. However, there are some problems raising when vegetable oil is used as fuel for diesel engines such as highly effected by cold weather, lower general efficiency, separation in layer if mixed with diesel oil and so on. To overcome that disadvantiges, the authors propose a new idea that to use a continuous fuel mixer to blend vegetable oil with diesel oil to make so called a mixed fuel supplying to diesel engines inline. In order to ensure a quality of the mixed fuel created by continuous mixer, a homogeneous testing was introduced with believable results. Then, the continuous mixer has been installed into fuel supply system of diesel engine 6LU32 at a lab of Vietnam Maritime University in terms of checking a real operation of the fuel continuous mixer with diesel engine.

  7. Effects of Crust Ingestion on Mixer Pump Performance in Tank 241-SY-101: Workshop Results

    International Nuclear Information System (INIS)

    Brennen, C.E.; Stewart, C.W.; Meyer, P.A.

    1999-01-01

    In August 1999, a workshop was held at Pacific Northwest National Laboratory to discuss the effects of crust ingestion on mixer pump performance in Hanford Waste Tank 241-SY-101. The main purpose of the workshop was to evaluate the potential for crust ingestion to degrade mixing and/or damage the mixer pump. The need for a previously determined 12-inch separation between the top of the mixer pump inlet and the crust base was evaluated. Participants included a representative from the pump manufacturer, an internationally known expert in centrifugal pump theory, Hanford scientists and engineers, and operational specialists representing relevant fields of expertise. The workshop focused on developing an understanding of the pump design, addressing the physics of entrainment of solids and gases into the pump, and assessing the effects of solids and gases on pump performance. The major conclusions are summarized as follows: (1) Entrainment of a moderate amount of solids or gas from the crust should not damage the pump or reduce its lifetime, though mixing effectiveness will be somewhat reduced. (2) Air binding should not damage the pump. Vibrations due to ingestion of gas, solids, and objects potentially could cause radial loads that might reduce the lifetime of bearings and seals. However, significant damage would require extreme conditions not associated with the small bubbles, fine solids, and chunks of relatively weak material typical of the crust. (3) The inlet duct extension opening, 235 inches from the tank bottom, should be considered the pump inlet, not the small gap at 262 inches. (4) A suction vortex exists at the inlet of all pumps. The characteristics of the inlet suction vortex in the mixer pump are very hard to predict, but its effects likely extend upward several feet. Because of this, the current 12-inch limit should be replaced with criteria based on actual monitored pump performance. The most obvious criterion (in addition to current operational

  8. A high conversion-gain Q-band InP DHBT subharmonic mixer using LO frequency doubler

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Vidkjær, Jens; Krozer, Viktor

    2008-01-01

    The paper presents analysis and design of a Q-band subharmonic mixer (SHM) with high conversion gain. The SHM consists of a local oscillator (LO) frequency doubler, RF pre-amplifier, and single-ended mixer. The SHM has been fabricated in a high-speed InP double heterojunction bipolar transistor (...

  9. Hydrodynamic study of the rotating cylinder mixer of a laboratory centrifugal extractor

    International Nuclear Information System (INIS)

    Philipponeau, Yannick.

    1979-08-01

    As part of a research programme on solvent extraction kinetics the Fontenay-aux-Roses Nuclear Research Centre has undertaken to build a new centrifugal extractor prototype. The work was centred on a hydrodynamic study of the rotating cylinder mixer of the extractor, using a test apparatus specially designed for this purpose. This apparatus was used to determine the flow conditions of a liquid alone in the annular space of the mixer as a function of the working specifications. The existence of several types of flow was established. The stability region of which was determined as a function of different parameters for a number of liquid-liquid systems. The experiments showed in addition that two kinds of dispersion can be obtained, differing by the nature of the continuous phase. This was determined for various parameters of certain liquid-liquid systems. From this research the hydrodynamic behavior of the CEA centrifugal extractor prototype mixer is thus known [fr

  10. High linearity current communicating passive mixer employing a simple resistor bias

    International Nuclear Information System (INIS)

    Liu Rongjiang; Guo Guiliang; Yan Yuepeng

    2013-01-01

    A high linearity current communicating passive mixer including the mixing cell and transimpedance amplifier (TIA) is introduced. It employs the resistor in the TIA to reduce the source voltage and the gate voltage of the mixing cell. The optimum linearity and the maximum symmetric switching operation are obtained at the same time. The mixer is implemented in a 0.25 μm CMOS process. The test shows that it achieves an input third-order intercept point of 13.32 dBm, conversion gain of 5.52 dB, and a single sideband noise figure of 20 dB. (semiconductor integrated circuits)

  11. Complete Procedure for Fabrication of a Fused Silica Ultrarapid Microfluidic Mixer Used in Biophysical Measurements

    Directory of Open Access Journals (Sweden)

    Dena Izadi

    2017-01-01

    Full Text Available In this paper we present a method to fabricate a fused silica microfluidic device by employing low viscosity KMPR photoresists. The resulting device is a continuous-flow microfluidic mixer based on hydrodynamic focusing. The advantages of this new fabrication method compared to the traditional approach using a poly-silicon mask are simplification, and time and cost reduction, while still preserving the quality and the performance of the mixers. This process results in devices in which the focusing channel has an aspect ratio of 10:1. The newly-fabricated mixer is successfully used to observe the folding of the Pin1 WW domain at the microsecond time scale.

  12. Design of the ME-I powder mixer. Report of the design and construction of the powder mixer, according to the safety requisites of the pellets fabrication process

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-03-01

    In order to fulfill the requirements of preparation of powder of UO 2 ; according to procedure P-M-PP-01, rev. 0, for the process of production of pellets, it was designed and manufactured a powders mixer to incorporate the lubricant one (zinc stearate) to the powder of UO 2 . This equipment allows to mix the powder of UO 2 evenly with the one zinc stearate, without forming considerable quantities of fine of UO 2 , besides a sure control for the operators of the process and an easy access to the mixer to inspect the mixture. (Author)

  13. Work plan for vibration cable re-route and water flush system modifications for 107-AN mixer pump

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1995-01-01

    A mixer pump (75 horsepower Hazleton submersible) is to be installed in the central pump pit of Double-Shell Tank 241-AN-107 for the Caustic Addition Project. The mixer pump will be used as a platform to inject, mix, and entrain caustic with the waste, in order to bring the waste hydroxyl ion concentration into compliance with Tank Farm operating specifications. Testing of the mixer pump and caustic addition system revealed that the mixer pump's vibration cable picks up electromagnetic interference from the motor power cable during variable speed operation of the pump. Also, it was noted that the mixer pump's water flush system may not be as effective as desired. Ergo this work plan for improving the operation of these mixer pump subsystems. A new vibration cable shall be routed entirely outside the mixer pump support column pipe, up thru a new penetration in the pump mounting flange. The existing penetration in the side of the pipe is to be plugged. Increasing the distance between power and instrument cables may reduce or eliminate electromagnetic interference to the vibration monitor. The mixer pump water flush system shall be modified to allow pressure isolation of individual branches. A header is to be installed on the middle section of the support column. Each branch (there are three) shall contain a solenoid valve (normally open) to control flow into the branch. The solenoid cables shall be routed up thru three new penetrations in the pump mounting flange to a new electrical box mounted on the flange. The existing flush piping to the inlet screen will remain but the continuation of the flush piping to the pump discharge nozzles is to be removed and the tee plugged. New stainless steel tubing is to be run down to the pump discharge nozzles. Pressure isolation of individual branches will maximize the flush system's effectiveness at blasting potential sediment clogs out of the pump discharge nozzles

  14. AZ-101 Mixer Pump Demonstration and Tests Data Management Analysis Plan

    Energy Technology Data Exchange (ETDEWEB)

    DOUGLAS, D.G.

    2000-02-22

    This document provides a plan for the analysis of the data collected during the AZ-101 Mixer Pump Demonstration and Tests. This document was prepared after a review of the AZ-101 Mixer Pump Test Plan (Revision 4) [1] and other materials. The plan emphasizes a structured and well-ordered approach towards handling and examining the data. This plan presumes that the data will be collected and organized into a unified body of data, well annotated and bearing the date and time of each record. The analysis of this data will follow a methodical series of steps that are focused on well-defined objectives. Section 2 of this plan describes how the data analysis will proceed from the real-time monitoring of some of the key sensor data to the final analysis of the three-dimensional distribution of suspended solids. This section also identifies the various sensors or sensor systems and associates them with the various functions they serve during the test program. Section 3 provides an overview of the objectives of the AZ-101 test program and describes the data that will be analyzed to support that test. The objectives are: (1) to demonstrate that the mixer pumps can be operated within the operating requirements; (2) to demonstrate that the mixer pumps can mobilize the sludge in sufficient quantities to provide feed to the private contractor facility, and (3) to determine if the in-tank instrumentation is sufficient to monitor sludge mobilization and mixer pump operation. Section 3 also describes the interim analysis that organizes the data during the test, so the analysis can be more readily accomplished. Section 4 describes the spatial orientation of the various sensors in the tank. This section is useful in visualizing the relationship of the Sensors in terms of their location in the tank and how the data from these sensors may be related to the data from other sensors. Section 5 provides a summary of the various analyses that will be performed on the data during the test

  15. AZ-101 Mixer Pump Demonstration and Tests: Data Management (Analysis) Plan

    International Nuclear Information System (INIS)

    DOUGLAS, D.G.

    2000-01-01

    This document provides a plan for the analysis of the data collected during the AZ-101 Mixer Pump Demonstration and Tests. This document was prepared after a review of the AZ-101 Mixer Pump Test Plan (Revision 4) [1] and other materials. The plan emphasizes a structured and well-ordered approach towards handling and examining the data. This plan presumes that the data will be collected and organized into a unified body of data, well annotated and bearing the date and time of each record. The analysis of this data will follow a methodical series of steps that are focused on well-defined objectives. Section 2 of this plan describes how the data analysis will proceed from the real-time monitoring of some of the key sensor data to the final analysis of the three-dimensional distribution of suspended solids. This section also identifies the various sensors or sensor systems and associates them with the various functions they serve during the test program. Section 3 provides an overview of the objectives of the AZ-101 test program and describes the data that will be analyzed to support that test. The objectives are: (1) to demonstrate that the mixer pumps can be operated within the operating requirements; (2) to demonstrate that the mixer pumps can mobilize the sludge in sufficient quantities to provide feed to the private contractor facility, and (3) to determine if the in-tank instrumentation is sufficient to monitor sludge mobilization and mixer pump operation. Section 3 also describes the interim analysis that organizes the data during the test, so the analysis can be more readily accomplished. Section 4 describes the spatial orientation of the various sensors in the tank. This section is useful in visualizing the relationship of the Sensors in terms of their location in the tank and how the data from these sensors may be related to the data from other sensors. Section 5 provides a summary of the various analyses that will be performed on the data during the test

  16. Robust Control Mixer Method for Reconfigurable Control Design Using Model Matching Strategy

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Blanke, Mogens; Verhagen, Michel

    2007-01-01

    A novel control mixer method for recon¯gurable control designs is developed. The proposed method extends the matrix-form of the conventional control mixer concept into a LTI dynamic system-form. The H_inf control technique is employed for these dynamic module designs after an augmented control...... system is constructed through a model-matching strategy. The stability, performance and robustness of the reconfigured system can be guaranteed when some conditions are satisfied. To illustrate the effectiveness of the proposed method, a robot system subjected to failures is used to demonstrate...

  17. Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

    Science.gov (United States)

    McGrath, W. R.

    1995-01-01

    Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

  18. The Robust Control Mixer Method for Reconfigurable Control Design By Using Model Matching Strategy

    DEFF Research Database (Denmark)

    Yang, Z.; Blanke, Mogens; Verhagen, M.

    2001-01-01

    This paper proposes a robust reconfigurable control synthesis method based on the combination of the control mixer method and robust H1 con- trol techniques through the model-matching strategy. The control mixer modules are extended from the conventional matrix-form into the LTI sys- tem form....... By regarding the nominal control system as the desired model, an augmented control system is constructed through the model-matching formulation, such that the current robust control techniques can be usedto synthesize these dynamical modules. One extension of this method with respect to the performance...... recovery besides the functionality recovery is also discussed under this framework. Comparing with the conventional control mixer method, the proposed method considers the recon gured system's stability, performance and robustness simultaneously. Finally, the proposed method is illustrated by a case study...

  19. Feasibility Study on Using Two Mixer Pumps for Tank 241-AY-102 Waste Mixing

    International Nuclear Information System (INIS)

    Onishi, Yasuo; Wells, Beric E.

    2004-01-01

    The current waste retrieval plan at Hanford calls for using two mixer pumps to mix the waste stored in double-shell Tank 214-AY-102. The objective of this evaluation was to determine whether two rotating 300-hp mixer pumps placed 22 ft (6.7 m) off-center in the tank could adequately mix the AY-102 waste. The tank currently contains high-level waste that is 248 inches (6.3 m) deep, comprising 62 inches (1.58 m) of sludge and 186 inches (4.72 m) of supernatant liquid (Galbraith and others 2002). Based on the available data, AY-102 waste properties were determined, including the densities of liquid and agglomerated settled solids and crystals, the volume fraction of settled solids, the solid particle size distribution, the liquid and slurry viscosities, and the yield stress in shear (shear strength) of the settled solids layer. To evaluate the likely and bounding cases of AY-102 waste mixing, sludge erosion modeling was performed with a median value of 1,090 Pa (likely condition) and a conservative (more difficult to erode) 97.5 percentile value of 2,230 Pa for shear strength. According to model predictions, the two rotating mixer pumps would erode 89% of the sludge with shear strength of 1,090 Pa. They would erode sludge up to 41 ft (12.5 m) away from the mixer pumps but would not mobilize the bottom 2.5 inches (0.06-m) of sludge or sludge in the areas next to the tank wall, more than 26 ft (7.9 m) away. Once the sludge is mobilized, the solids were predicted to be uniformly suspended within the tank within a 1-vol% concentration variation except those in few inches at the bottom. With shear strength of 2,230 Pa, the two pumps would erode 85% of the sludge, slightly less than the 1,090-Pa shear strength case. In this case, the pump jets would mobilize the sludge up to 38 ft (11.6 m), except the bottom 2.5 inches of sludge. The mixer pumps would also leave the sludge at the tank wall, which is 20 ft or more from the pumps. Similar to the 1,090 Pa case, the solids were

  20. The status of simulation codes for extraction process using mixer-settler

    Energy Technology Data Exchange (ETDEWEB)

    Byeon, Kee Hoh; Lee, Eil Hee; Kwon, Seong Gil; Kim, Kwang Wook; Yang, Han Beom; Chung, Dong Yong; Lim, Jae Kwan; Shin, Hyun Kyoo; Kim, Soo Ho

    1999-10-01

    We have studied and analyzed the mixer-settler simulation codes such as three kinds of SEPHIS series, PUBG, and EXTRA.M, which is the most recently developed code. All of these are sufficiently satisfactory codes in the fields of process/device modeling, but it is necessary to formulate the accurate distribution data and chemical reaction mechanism for the aspect of accuracy and reliability. In the aspect of application to be the group separation process, the mixer-settler model of these codes have no problems, but the accumulation and formulation of partitioning and reaction equilibrium data of chemical elements used in group separation process is very important. (author)

  1. Design of an Efficient Turbulent Micro-Mixer for Protein Folding Experiments

    Science.gov (United States)

    Inguva, Venkatesh; Perot, Blair

    2015-11-01

    Protein folding studies require the development of micro-mixers that require less sample, mix at faster rates, and still provide a high signal to noise ratio. Chaotic to marginally turbulent micro-mixers are promising candidates for this application. In this study, various turbulence and unsteadiness generation concepts are explored that avoid cavitation. The mixing enhancements include flow turning regions, flow splitters, and vortex shedding. The relative effectiveness of these different approaches for rapid micro-mixing is discussed. Simulations found that flow turning regions provided the best mixing profile. Experimental validation of the optimal design is verified through laser confocal microscopy experiments. This work is support by the National Science Foundation.

  2. Influence of melt mixer on injection molding of thermoset elastomers

    Science.gov (United States)

    Rochman, Arif; Zahra, Keith

    2016-10-01

    One of the drawbacks in injection molding is that the plasticizing screw is short such that polymers having high concentrations of additives, such as thermoset elastomers, might not mix homogeneously within the short period of time during the plasticizing stage. In this study, various melt mixers inside the nozzle chamber, together forming a mixing nozzle, were developed. Three different materials were investigated, namely nitrile butadiene rubber (NBR), ethylene propylene-diene monomer (EPDM) and fluorocarbon (FKM). The use of these melt mixers resulted in better homogeneity and properties of the molded parts despite a curing time reduction of 10 s. This was due to the increase in mixing and shearing introduced a higher rate of crosslinking formation in the molded parts.

  3. Automated design system for a rotor with an ellipse lobe profile

    International Nuclear Information System (INIS)

    Jung, Sung Yuen; Kim Chul; Han, Seung Moo; Cho, Hae Yong

    2009-01-01

    An internal lobe pump (ILP) is suitable for machine tool oil hydraulics, automotive engines, compressors, and various other devices. In particular, the ILP is an essential component of an automotive engine, used to feed lubricant oil through the system. The main components of an ILP are its rotors. The outer rotor is typically characterized by lobes with an elliptical shape, and the inner rotor profile is a conjugate to the outer profile. This paper describes a theoretical analysis of an ILP and the development of an integrated automated system for rotor design. This system is composed of three main modules and has been developed using AutoLISP for the AutoCAD program. The system generates a new lobe profile and automatically calculates flow rate and flow rate irregularity according to the lobe profile generated. Results obtained from the analysis can enable oil pump designers and manufacturers to become more efficient

  4. Automated design system for a rotor with an ellipse lobe profile

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sung Yuen; Kim Chul [Pusan National University, Busan (Korea, Republic of); Han, Seung Moo [Kyung Hee University, Seoul (Korea, Republic of); Cho, Hae Yong [Chungbuk National University, Cheongju (Korea, Republic of)

    2009-11-15

    An internal lobe pump (ILP) is suitable for machine tool oil hydraulics, automotive engines, compressors, and various other devices. In particular, the ILP is an essential component of an automotive engine, used to feed lubricant oil through the system. The main components of an ILP are its rotors. The outer rotor is typically characterized by lobes with an elliptical shape, and the inner rotor profile is a conjugate to the outer profile. This paper describes a theoretical analysis of an ILP and the development of an integrated automated system for rotor design. This system is composed of three main modules and has been developed using AutoLISP for the AutoCAD program. The system generates a new lobe profile and automatically calculates flow rate and flow rate irregularity according to the lobe profile generated. Results obtained from the analysis can enable oil pump designers and manufacturers to become more efficient

  5. OCCIPITAL LOBE SYNDROME

    OpenAIRE

    Shahdevi Nandar Kurniawan

    2016-01-01

    The ability to recognize objects and words is not just depend on the integrity of visual pathway and primary vision area on cerebral cortex (Brodmann area 17), but also secondary vision area 18 and tertiary vision area 19 on occipital lobe. Lesion in occipital lobe could disturb of human visual function such as visual field defects, inability to recognize colors, inability to recognize words, visual hallucinations and illusions, occipital lobe epilepsy, and Anton’s syndrome. Some causes of oc...

  6. Wide-bandwidth electron bolometric mixers - A 2DEG prototype and potential for low-noise THz receivers

    Science.gov (United States)

    Yang, Jian-Xun; Agahi, Farid; Dai, Dong; Musante, Charles F.; Grammer, Wes; Lau, Kei M.; Yngvesson, K. S.

    1993-01-01

    This paper presents a new type of electron bolometric ('hot electron') mixer. We have demonstrated a 3 order-of-magnitude improvement in the bandwidth compared with previously known types of electron bolometric mixers, by using the two-dimensional electron gas (2DEG) medium at the heterointerface between AlGaAs and GaAs. We have tested both in-house MOCVD-grown material and MBE material, with similar results. The conversion loss (Lc) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that Lc can be decreased to about 10 dB in future devices. Calculated and measured curves of Lc versus P(LO), and I(DC), respectively, agree well. We argue that there are several different configurations of electron bolometric mixers, which will all show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.

  7. A Low Power 2.4 GHz CMOS Mixer Using Forward Body Bias Technique for Wireless Sensor Network

    Science.gov (United States)

    Yin, C. J.; Murad, S. A. Z.; Harun, A.; Ramli, M. M.; Zulkifli, T. Z. A.; Karim, J.

    2018-03-01

    Wireless sensor network (WSN) is a highly-demanded application since the evolution of wireless generation which is often used in recent communication technology. A radio frequency (RF) transceiver in WSN should have a low power consumption to support long operating times of mobile devices. A down-conversion mixer is responsible for frequency translation in a receiver. By operating a down-conversion mixer at a low supply voltage, the power consumed by WSN receiver can be greatly reduced. This paper presents a development of low power CMOS mixer using forward body bias technique for wireless sensor network. The proposed mixer is implemented using CMOS 0.13 μm Silterra technology. The forward body bias technique is adopted to obtain low power consumption. The simulation results indicate that a low power consumption of 0.91 mW is achieved at 1.6 V supply voltage. Moreover, the conversion gain (CG) of 21.83 dB, the noise figure (NF) of 16.51 dB and the input-referred third-order intercept point (IIP3) of 8.0 dB at 2.4 GHz are obtained. The proposed mixer is suitable for wireless sensor network.

  8. Flicker noise comparison of direct conversion mixers using Schottky and HBT dioderings in SiGe:C BiCMOS technology

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus Schandorph; Johansen, Tom Keinicke; Tamborg, Kjeld

    2015-01-01

    In this paper, we present flicker noise measurements of two X-band direct conversion mixers implemented in a SiGe:C BiCMOS technology. Both mixers use a ring structure with either Schottky diodes or diode-connected HBTs for double balanced operation. The mixers are packaged in a metal casing on a...... circuit demonstrates a 1/f noise corner frequency around 10 kHz....

  9. Inverted Lobes Have Satisfactory Functions Compared With Noninverted Lobes in Lung Transplantation.

    Science.gov (United States)

    Kayawake, Hidenao; Chen-Yoshikawa, Toyofumi F; Motoyama, Hideki; Hamaji, Masatsugu; Hijiya, Kyoko; Aoyama, Akihiro; Goda, Yasufumi; Oda, Hiromi; Ueda, Satoshi; Date, Hiroshi

    2018-04-01

    To overcome the problem of small-for-size grafts in standard living-donor lobar lung transplantation (LDLLT), we developed inverted LDLLT, in which a right lower lobe from 1 donor is implanted as a right graft and another right lower lobe from another donor is implanted as a left graft. We retrospectively analyzed the functions of inverted grafts vs noninverted grafts. Between 2008 and 2015, 64 LDLLTs were performed. Included were 35 LDLLTs whose recipients were adults and monitored for more than 6 months without developing chronic lung allograft dysfunction. Among them, 65 implanted lobes were eligible for this analysis. There were 31 right lower lobes implanted as right grafts (right-to-right group), 7 right lower lobes as inverted left grafts (right-to-left group), and 27 left lower lobes as left grafts (left-to-left group). We evaluated the graft forced vital capacity (G-FVC) and graft volume of the 65 lobes before and 6 months after LDLLT and compared them among the three groups. Preoperatively, G-FVC in the right-to-left group (1,050 mL) was comparable to that in the right-to-right group (1,177 mL) and better than that in the left-to-left group (791 mL, p satisfactory compared with those of noninverted grafts. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Scale-up of a mixer-settler extractor using a unit operations approach

    International Nuclear Information System (INIS)

    Lindholm, D.C.; Bautista, R.G.

    1976-01-01

    The results of scale-up studies on a continuous, multistage horizontal mixer-settler extractor are presented. The chemical and mechanical system involves the separation of lanthanum from a mixture of rare earth chlorides using di(2-ethylhexyl) phosphoric acid as the solvent and dilute HCl as a scrub solution in a bench scale extractor. Each stage has a hold-up of 2.6 l. A single stage unit is utilized for scale-up studies. Results are obtained on four sizes of geometrically similar units, the largest being six times the volume of the original bench size. A unit operations technique is chosen so that mixing and settling can be examined independently. Variables examined include type of continuous phase, flow rate of inlet streams, and power input to the mixer. Inlet flow-rate ratios are kept constant for all tests. Two potential methods of unbaffled pump-mixer scale-up are explored; the maintenance of constant impeller tip speed and constant power input. For the settler, the previously successful method of basing design on constant flow-rate per unit cross-sectional area is used

  11. Analysis of a high-Tc hot-electron superconducting mixer for terahertz applications

    International Nuclear Information System (INIS)

    Karasik, B.S.; McGrath, W.R.; Gaidis, M.C.

    1997-01-01

    The prospects of a YBa 2 Cu 3 O 7-δ hot-electron bolometer mixer for a THz heterodyne receiver are discussed. The modeled device is a submicron bridge made from a 10-nm-thick film on a high thermal conductance substrate. The mixer performance expected for this device is analyzed in the framework of a two-temperature model which includes heating both of the electrons and the lattice. Also, the contribution of phonon diffusion from the film through the substrate and from the film to the normal metal contacts is evaluated. The intrinsic conversion efficiency and the noise temperature have been calculated as functions of the device size, local oscillator (LO) power, and ambient temperature. Assuming thermal fluctuations and Johnson noise to be the main sources of noise, a minimum single sideband mixer noise temperature of congruent 2000 K is predicted. For our modeled device the intrinsic conversion loss at an intermediate frequency of 2.5 GHz is less than 10 dB and the required LO power is ∼1 endash 10 μW. copyright 1997 American Institute of Physics

  12. Numerical study of agglomerate abrasion in a tumbling mixer

    NARCIS (Netherlands)

    Thanh Nguyen, [No Value; Willemsz, Tofan; Frijlink, Henderik; Maarschalk, Kees van der Voort

    2014-01-01

    A numerical simulation using the Discrete Element Method (DEM) was performed to investigate the phenomena concerning the abrasion and breakage of agglomerates in a diffusion powder mixer. Agglomerates were created by defining a single structure of particles with bonds of different strengths using

  13. Frontal Lobe Seizures

    Science.gov (United States)

    ... cause of frontal lobe epilepsy remains unknown. Complications Status epilepticus. Frontal lobe seizures tend to occur in clusters and may provoke a dangerous condition called status epilepticus — in which seizure activity lasts much longer than ...

  14. Investigation of LO-leakage cancellation and DC-offset influence on flicker-noise in X-band mixers

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus; Johansen, Tom; Tamborg, Kjeld

    2012-01-01

    This paper describes an investigation on the influences in 1/f noise of LO-leakage and DC-offset cancellation for X-band mixers. Conditions for LO-leakage cancellation and zero DC-offset is derived. Measurements on a double balanced diode mixer shows an improvement in noise figure from 14.3dB to ...

  15. Review of mixer design for low voltage - low power applications

    Science.gov (United States)

    Nurulain, D.; Musa, F. A. S.; Isa, M. Mohamad; Ahmad, N.; Kasjoo, S. R.

    2017-09-01

    A mixer is used in almost all radio frequency (RF) or microwave systems for frequency translation. Nowadays, the increase market demand encouraged the industry to deliver circuit designs to create proficient and convenient equipment with very low power (LP) consumption and low voltage (LV) supply in both digital and analogue circuits. This paper focused on different Complementary Metal Oxide Semiconductor (CMOS) design topologies for LV and LP mixer design. Floating Gate Metal Oxide Semiconductor (FGMOS) is an alternative technology to replace CMOS due to their high ability for LV and LP applications. FGMOS only required a few transistors per gate and can have a shift in threshold voltage (VTH) to increase the LP and LV performances as compared to CMOS, which makes an attractive option to replace CMOS.

  16. The Media Mixer

    DEFF Research Database (Denmark)

    Vestergaard, Vitus; Mortensen, Christian Hviid

    In recent years many museums have experimented with different approaches to involving users through digital media. We explore how remixing and content sharing can be used as a means for user participation. Remix culture is seen as a culture that allows and encourages the production of derivative...... works; works that are based on already existing works. This cultural practice thrives throughout the Internet, most notably on web2.0 sites like YouTube. The Media Museum has embraced the remix paradigm with the development of an interactive media experience centre called the Media Mixer. Here...... the museum users can produce, deconstruct, reconstruct and finally publish and share digital media content. The media content is created by the user in the museums physical environment, but it can be mixed with material from local or global archives. In that way the gap between the analogue and the digital...

  17. The Media Mixer

    DEFF Research Database (Denmark)

    Vestergaard, Vitus; Mortensen, Christian Hviid

    2011-01-01

    content. The media content is created by the user in the museum's physical environment, but it can be mixed with material from web archives. It is the intention that the users learn about media through participatory and creative processes with media where the borders between producing, playing......We explore how remixing and content sharing can be used as a means for user participation in a digital museum age. Remix culture is seen as a culture that allows and encourages the production of derivative works; works that are based on already existing works. This cultural practice thrives...... throughout the Internet, most notably on web 2.0 sites like YouTube. The Media Museum has embraced the remix paradigm with the development of an interactive media experience centre called the Media Mixer. Here the museum users can produce, deconstruct, reconstruct and finally publish and share digital media...

  18. Mixing monoclonal antibody formulations using bottom-mounted mixers: impact of mechanism and design on drug product quality.

    Science.gov (United States)

    Gikanga, Benson; Chen, Yufei; Stauch, Oliver B; Maa, Yuh-Fun

    2015-01-01

    Using bottom-mounted mixers, particularly those that are magnetically driven, is becoming increasingly common during the mixing process in pharmaceutical and biotechnology manufacturing because of their associated low risk of contamination, ease of use, and ability to accommodate low minimum mixing volumes. Despite these benefits, the impact of bottom-mounted mixers on biologic drug product is not yet fully understood and is scarcely reported. This study evaluated four bottom-mounted mixers to assess their impact on monoclonal antibody formulations. Changes in product quality (size variants, particles, and turbidity) and impact on process performance (sterile filtration) were evaluated after mixing. The results suggested that mixers that are designed to function with no contact between the impeller and the drive unit are the most favorable and gentle to monoclonal antibody molecules. Designs with contact or a narrow clearance tended to shear and grind the protein and resulted in high particle count in the liquid, which would subsequently foul a filter membrane during sterile filtration using a 0.22 μm pore size filter. Despite particle formation, increases in turbidity of the protein solution and protein aggregation/fragmentation were not detected. Further particle analysis indicated particles in the range of 0.2-2 μm are responsible for filter fouling. A small-scale screening model was developed using two types of magnetic stir bars mimicking the presence or absence of contact between the impeller and drive unit in the bottom-mounted mixers. The model is capable of differentiating the sensitivity of monoclonal antibody formulations to bottom-mounted mixers with a small sample size. This study fills an important gap in understanding a critical bioprocess unit operation. Mixing is an important unit operation in drug product manufacturing for compounding (dilution, pooling, homogenization, etc.). The current trend in adopting disposable bottom-mounted mixers has

  19. A Sideband-Separating Mixer Upgrade for ALMA Band 9

    NARCIS (Netherlands)

    Hesper, R.; Gerlofsma, G.; Mena, P.; Spaans, M.; Baryshev, A.

    2009-01-01

    The ALMA band 9 (600-720 GHz) receiver cartridge, as currently being produced, features two single-ended (dual sideband) SIS mixers in orthogonal polarisations. In the case of spectral line observations in the presence of atmospheric backgound, the integration time to reach a certain desired signal

  20. A “twisted” microfluidic mixer suitable for a wide range of flow rate applications

    KAUST Repository

    Sivashankar, Shilpa

    2016-06-27

    This paper proposes a new “twisted” 3D microfluidic mixer fabricated by a laser writing/microfabrication technique. Effective and efficient mixing using the twisted micromixers can be obtained by combining two general chaotic mixing mechanisms: splitting/recombining and chaotic advection. The lamination of mixer units provides the splitting and recombination mechanism when the quadrant of circles is arranged in a two-layered serial arrangement of mixing units. The overall 3D path of the microchannel introduces the advection. An experimental investigation using chemical solutions revealed that these novel 3D passive microfluidic mixers were stable and could be operated at a wide range of flow rates. This micromixer finds application in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted micromixer was made to evaluate the efficiency of mixing. The efficiency of mixing was calculated within the channel by acquiring intensities using ImageJ software. Results suggested that efficient mixing can be obtained when more than 3 units were consecutively placed. The geometry of the device, which has a length of 30 mm, enables the device to be integrated with micro total analysis systems and other lab-on-chip devices.

  1. Introduction and utilization of mixer-settler for uranium purification

    International Nuclear Information System (INIS)

    Tri-Murni

    2002-01-01

    A mixer settler made by Amersham was designed to separate U from the waste arising from 9 9 M o production using enriched U > 93 % 2 35 U as the raw material to be fissioned. The separation is based on liquid-liquid extraction, organic and aqueous phase, with counter current, the solution continuously flows while the two phases are mixed and settled. This equipment consists of two cycles, the first one for separation U from fission products while the second cycle for separating U from Pu. Each cycle consists of 10 extraction stages, 6 scrubbing stages, 12 stripping stages, 1 stages for solvent washing and another 1 stage for solvent conditioning. From the first cycle to the second one is equipped with solvent washing unit so that the solvent can be used continuously. It is also equipped with micro pumps to regulate the suction and emission of the waste and feed thanks of feed and solvent, as well as burette containing the reagent. Ever since the commissioning this mixer settler has been utilized. This equipment can be utilized for U purification from heavy metals using the product of U processing as the feed material by studying the appropriate solution and applicable solvent. The same also will do for U separation from impurities is the waste of fuel production and other wastes solvent. The same also will do for U separation from impurities in the waste of fuel production and other wastes containing U generated from research activities. The centers within BATAN that can utilize this mixer settler are P2BGGN, P2TBDU, P2PLR, P3TkN and P3TM

  2. The gyri of the octopus vertical lobe have distinct neurochemical identities.

    Science.gov (United States)

    Shigeno, Shuichi; Ragsdale, Clifton W

    2015-06-15

    The cephalopod vertical lobe is the largest learning and memory structure known in invertebrate nervous systems. It is part of the visual learning circuit of the central brain, which also includes the superior frontal and subvertical lobes. Despite the well-established functional importance of this system, little is known about neuropil organization of these structures and there is to date no evidence that the five longitudinal gyri of the vertical lobe, perhaps the most distinctive morphological feature of the octopus brain, differ in their connections or molecular identities. We studied the histochemical organization of these structures in hatchling and adult Octopus bimaculoides brains with immunostaining for serotonin, octopus gonadotropin-releasing hormone (oGNRH), and octopressin-neurophysin (OP-NP). Our major finding is that the five lobules forming the vertical lobe gyri have distinct neurochemical signatures. This is most prominent in the hatchling brain, where the median and mediolateral lobules are enriched in OP-NP fibers, the lateral lobule is marked by oGNRH innervation, and serotonin immunostaining heavily labels the median and lateral lobules. A major source of input to the vertical lobe is the superior frontal lobe, which is dominated by a neuropil of interweaving fiber bundles. We have found that this neuropil also has an intrinsic neurochemical organization: it is partitioned into territories alternately enriched or impoverished in oGNRH-containing fascicles. Our findings establish that the constituent lobes of the octopus superior frontal-vertical system have an intricate internal anatomy, one likely to reflect the presence of functional subsystems within cephalopod learning circuitry. © 2015 Wiley Periodicals, Inc.

  3. Temporal lobe sclerosis associated with hippocampal sclerosis in temporal lobe epilepsy: neuropathological features.

    Science.gov (United States)

    Thom, Maria; Eriksson, Sofia; Martinian, Lillian; Caboclo, Luis O; McEvoy, Andrew W; Duncan, John S; Sisodiya, Sanjay M

    2009-08-01

    Widespread changes involving neocortical and mesial temporal lobe structures can be present in patients with temporal lobe epilepsy and hippocampal sclerosis. The incidence, pathology, and clinical significance of neocortical temporal lobe sclerosis (TLS) are not well characterized. We identified TLS in 30 of 272 surgically treated cases of hippocampal sclerosis. Temporal lobe sclerosis was defined by variable reduction of neurons from cortical layers II/III and laminar gliosis; it was typically accompanied by additional architectural abnormalities of layer II, that is, abnormal neuronal orientation and aggregation. Quantitative analysis including tessellation methods for the distribution of layer II neurons supported these observations. In 40% of cases, there was a gradient of TLS with more severe involvement toward the temporal pole, possibly signifying involvement of hippocampal projection pathways. There was a history of a febrile seizure as an initial precipitating injury in 73% of patients with TLS compared with 36% without TLS; no other clinical differences between TLS and non-TLS cases were identified. Temporal lobe sclerosis was not evident preoperatively by neuroimaging. No obvious effect of TLS on seizure outcome was noted after temporal lobe resection; 73% became seizure-free at 2-year follow-up. In conclusion, approximately 11% of surgically treated hippocampal sclerosis is accompanied by TLS. Temporal lobe sclerosis is likely an acquired process with accompanying reorganizational dysplasia and an extension of mesial temporal sclerosis rather than a separate pathological entity.

  4. Effect of mixing time and speed on experimental baking and dough testing with a 200g pin-mixer

    Science.gov (United States)

    Under mixing or over mixing the dough results in varied experimental loaf volumes. Bread preparation requires a trained baker to evaluate dough development and determine stop points of mixer. Instrumentation and electronic control of the dough mixer would allow for automatic mixing. This study us...

  5. Comparative evaluation of a two stroke compressed natural gas mixer design using simulation and experimental techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ramasamy, D.; Bakar, R.A.; Rahim, M.F.; Noor, M.M. [Malaysia Pahang Univ., Pahang (Malaysia). Automotive Focus Group

    2008-07-01

    A study was conducted in which a two-stroke engine was converted for use with bi-fuel, notably compressed natural gas and gasoline. The excessive by-products generated by two-stroke engine combustion can be attributed to the inefficient combustion process. This prototype uniflow-type single-cylinder engine was equipped with a bi-fuel conversion system. A dedicated mixer was also developed to meter the gaseous fuel through the engine intake system. It was designed to meet air and fuel requirement similar to its gasoline counterpart. The mixer was modeled to obtain optimum orifice diameter using three different sizes of 14, 16 and 18 mm respectively. A standard computational fluid dynamics (CFD) software package was used to simulate the flow. A pressure reading was obtained during the prototype test. The drop in pressure across the venturi was shown to be an important parameter as it determined the actual fuel-air ratio in the actual engine. A good agreement of CFD outputs with that of the experimental outputs was recorded. The experimental technique validated the pressure distribution predicted by CFD means on the effects of the three insert rings in the CNG mixer. The simulation exercise can be used to predict the amount of CNG consumed by the engine. It was concluded that the 14 mm throat ring was best suited for the CNG mixer because it provided the best suction. Once the mixer is tested on a real engine, it will clear any doubts as to whether the throat can function at high engine speeds. 5 refs., 3 tabs., 8 figs.

  6. Quantum noise in a terahertz hot electron bolometer mixer

    NARCIS (Netherlands)

    Zhang, W.; Khosropanah, P.; Gao, J. R.; Kollberg, E. L.; Yngvesson, K. S.; Bansal, T.; Barends, R.; Klapwijk, T. M.

    2010-01-01

    We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model

  7. Handling support for mixer-settlers in hot cells with biological protection

    International Nuclear Information System (INIS)

    Lobao, Afonso dos Santos Tome; Forbicini, Sergio; Camilo, Ruth Luqueze

    1996-01-01

    The solvent extraction research facilities of IPEN/CNEN-SP carries out researching work in irradiated materials separation. This installation is provided with two cells with five operating windows, being that, each once of then has a pair of manipulators (master-slave type-MA-11 La Calhene). Solvent extraction research are carried out in acrylic mixer-settlers inside of the shielded cells. These equipment undergo an intense chemical attack which product failures in the acrylic material, so it is necessary to replace them periodically. The developed equipment is able to change the mixer-settlers without its rigidness,, level and the adjustment of the determined coordinates of the mechanical assemblage inside the cell. The definitive implantation of the equipment depends on the final tests on the cells where the fine adjustments will be made. (author)

  8. An unsteady microfluidic T-form mixer perturbed by hydrodynamic pressure

    International Nuclear Information System (INIS)

    Ma Yanbao; Sun, Chien-Pin; Fields, Michael; Ho, Chih-Ming; Li Yang; Haake, David A; Churchill, Bernard M

    2008-01-01

    An unsteady microfluidic T-form mixer driven by pressure disturbances was designed and investigated. The performance of the mixer was examined both through numerical simulation and experimentation. Linear Stokes equations were used for these low Reynolds number flows. Unsteady mixing in a micro-channel of two aqueous solutions differing in concentrations of chemical species was described using a convection-dominated diffusion equation. The task was greatly simplified by employing linear superimposition of a velocity field for solving a scalar species concentration equation. Low-order-based numerical codes were found not to be suitable for simulation of a convection-dominated mixing process due to erroneous computational dissipation. The convection-dominated diffusion problem was addressed by designing a numerical algorithm with high numerical accuracy and computational-cost effectiveness. This numerical scheme was validated by examining a test case prior to being applied to the mixing simulation. Parametric analysis was performed using this newly developed numerical algorithm to determine the best mixing conditions. Numerical simulation identified the best mixing condition to have a Strouhal number (St) of 0.42. For a T-junction mixer (with channel width = 196 µm), about 75% mixing can be finished within a mixing distance of less than 3 mm (i.e. 15 channel width) at St = 0.42 for flow with a Reynolds number less than 0.24. Numerical results were validated experimentally by mixing two aqueous solutions containing yellow and blue dyes. Visualization of the flow field under the microscope revealed a high level of agreement between numerical simulation and experimental results

  9. Use of explicit memory cues following parietal lobe lesions.

    Science.gov (United States)

    Dobbins, Ian G; Jaeger, Antonio; Studer, Bettina; Simons, Jon S

    2012-11-01

    The putative role of the lateral parietal lobe in episodic memory has recently become a topic of considerable debate, owing primarily to its consistent activation for studied materials during functional magnetic resonance imaging studies of recognition. Here we examined the performance of patients with parietal lobe lesions using an explicit memory cueing task in which probabilistic cues ("Likely Old" or "Likely New"; 75% validity) preceded the majority of verbal recognition memory probes. Without cues, patients and control participants did not differ in accuracy. However, group differences emerged during the "Likely New" cue condition with controls responding more accurately than parietal patients when these cues were valid (preceding new materials) and trending towards less accuracy when these cues were invalid (preceding old materials). Both effects suggest insufficient integration of external cues into memory judgments on the part of the parietal patients whose cued performance largely resembled performance in the complete absence of cues. Comparison of the parietal patients to a patient group with frontal lobe lesions suggested the pattern was specific to parietal and adjacent area lesions. Overall, the data indicate that parietal lobe patients fail to appropriately incorporate external cues of novelty into recognition attributions. This finding supports a role for the lateral parietal lobe in the adaptive biasing of memory judgments through the integration of external cues and internal memory evidence. We outline the importance of such adaptive biasing through consideration of basic signal detection predictions regarding maximum possible accuracy with and without informative environmental cues. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. A SiGe High Gain and Highly Linear F-Band Single-Balanced Subharmonic Mixer

    OpenAIRE

    Seyedhosseinzadeh, Neda; Nabavi, Abdolreza; Carpenter, Sona; He, Zhongxia Simon; Bao, Mingquan; Zirath, Herbert

    2017-01-01

    A compact, broadband, high gain, second-order active down-converter subharmonic mixer is demonstrated using a 130-nm SiGe BiCMOS technology. The mixer adopts a bottom-LO Gilbert topology, on-chip RF and LO baluns and two emitter-follower buffers to realize a high gain wideband operation in both RF and IF frequencies. The measured performance exhibits a flat conversion gain (CG) of about 11 dB from 90 to 130 GHz with an average LO power of +3 dBm and high 2LO-RF isolation better than 60 dB. Th...

  11. Fabrication of microfluidic mixers with varying topography in glass using the powder-blasting process

    International Nuclear Information System (INIS)

    Sayah, Abdeljalil; Thivolle, Pierre-Antoine; Parashar, Virendra K; Gijs, Martin A M

    2009-01-01

    The powder-blasting method is used to fabricate structures with a three-dimensional topography in glass using elastomeric masks. The relation between the mask opening width and the erosion depth is exploited to fabricate microstructures with varying depth in a single micropatterning step. As an application, planar three-dimensional micro-mixers were fabricated, which consist of a repeating convergent microfluidic nozzle structure. Three different designs of the micro-mixers were considered. The mixing of co-flowing laminar streams results from the generation of multiple vortices at the exit of the different convergent nozzles

  12. THERMAL PLASMA IN THE GIANT LOBES OF THE RADIO GALAXY CENTAURUS A

    Energy Technology Data Exchange (ETDEWEB)

    O' Sullivan, S. P.; Feain, I. J.; McClure-Griffiths, N. M.; Ekers, R. D.; Carretti, E. [CSIRO Astronomy and Space Science, ATNF, P.O. Box 76, Epping, NSW 1710 (Australia); Robishaw, T. [Herzberg Institute of Astrophysics, Dominion Radio Astrophysical Observatory, P.O. Box 248, Penticton, BC V2A 6J9 (Canada); Mao, S. A. [National Radio Astronomy Observatory, P.O. Box O, Socorro, NM 87801 (United States); Gaensler, B. M.; Bland-Hawthorn, J. [Sydney Institute for Astronomy, School of Physics, The University of Sydney, NSW 2006 (Australia); Stawarz, L. [Institute of Space and Astronautical Science, JAXA, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan)

    2013-02-20

    We present a Faraday rotation measure (RM) study of the diffuse, polarized, radio emission from the giant lobes of the nearest radio galaxy, Centaurus A. After removal of the smooth Galactic foreground RM component, using an ensemble of background source RMs located outside the giant lobes, we are left with a residual RM signal associated with the giant lobes. We find that the most likely origin of this residual RM is from thermal material mixed throughout the relativistic lobe plasma. The alternative possibility of a thin-skin/boundary layer of magnetoionic material swept up by the expansion of the lobes is highly unlikely since it requires, at least, an order of magnitude enhancement of the swept-up gas over the expected intragroup density on these scales. Strong depolarization observed from 2.3 to 0.96 GHz also supports the presence of a significant amount of thermal gas within the lobes; although depolarization solely due to RM fluctuations in a foreground Faraday screen on scales smaller than the beam cannot be ruled out. Considering the internal Faraday rotation scenario, we find a thermal gas number density of {approx}10{sup -4} cm{sup -3}, implying a total gas mass of {approx}10{sup 10} M {sub Sun} within the lobes. The thermal pressure associated with this gas (with temperature kT {approx} 0.5 keV, obtained from recent X-ray results) is approximately equal to the non-thermal pressure, indicating that over the volume of the lobes, there is approximate equipartition between the thermal gas, radio-emitting electrons, and magnetic field (and potentially any relativistic protons present).

  13. CERN Entrepreneur Mixer | 21 June | Pas perdus

    CERN Multimedia

    2016-01-01

      CERN Knowledge Transfer group is hosting an Entrepreneur Mixer, an event dedicated to building bridges between CERN innovative entrepreneurs. This will be a unique opportunity to discover business projects initiated by former CERN people, and to see how CERN technology is being exploited by start-up companies. The deadline for registration is Friday, 17 June. For more information, please visit the Indico page of the event: https://indico.cern.ch/event/537167/

  14. Field measurement of mixing degree in coal mixer by later activable tracer method

    International Nuclear Information System (INIS)

    Yokooji, Makoto; Uemura, Katsumi; Adachi, Syoichi

    1975-01-01

    Mixing effectiveness in a rotary drum mixer for coke production was examined. Though the method to use the dispersion of characteristic values such as ash content or volatile components is common for measuring the mixing effectiveness, here the later activable tracer method with radioisotopes was employed, because the former method includes the dispersion of the characteristic values for raw materials themselves, and is poor in detectability. In a preliminary test, the expression for mixing degree was determined, and the tracer nuclide was selected. Coal mixture was irradiated in the TRIGA II reactor of St. Paul University for 4 hours at 100 kW. then further preliminary test was performed for La and Mn which were selected among the typical usable elements listed up by reviewing their γ-spectra. Finally, Mn was adopted by comparing both elements regarding their time required for activation analysis and economy. Manganese concentration originally contained in the coal mixture was 38 ppm. Mixing degree after passing through the coal mixer was 99.8%. The results of the regular test are shown in a table, and indicate that the mixer fully attained its aim. (Wakatsuki, Y.)

  15. Numerical simulation of experimental data from planar SIS mixers with integrated tuning elements

    International Nuclear Information System (INIS)

    Mears, C.A.; Hu, Qing; Richards, P.L.

    1988-08-01

    We have used the full Tucker theory including the quantum susceptance to fit data from planar lithographed mm-wave mixers with bow tie antennas and integrated RF coupling elements. Essentially perfect fits to pumped IV curves have been obtained. The deduced imbedding admittances agree well with those independently calculated from the geometry of the antenna and matching structures. We find that the quantum susceptance is essential to the fit and thus to predictions of the mixer performance. For junctions with moderately sharp gap structures, the quantum susceptance is especially important in the production of steps with low and/or negative dynamic conductance. 15 refs., 4 figs

  16. Comparison of the performance of full scale pulsed columns vs. mixer-settlers for uranium solvent extraction

    International Nuclear Information System (INIS)

    Movsowitz, R.L.; Kleinberger, R.; Buchalter, E.M.; Grinbaum, B.

    2000-01-01

    A rare opportunity arose to compare the performance of Bateman Pulsed Columns (BPC) vs. Mixer-Settlers at an industrial site, over a long period, when the Uranium Solvent Extraction Plant of WMC at Olympic Dam, South Australia was upgraded. The original plant was operated for years with two trains of 2-stage mixer-settler batteries for the extraction of uranium. When the company decided to increase the yield of the plant, the existing two trains of mixer-settlers for uranium extraction were arranged in series, giving one 4-stage battery. In parallel, two Bateman Pulsed Columns, of the disc-and-doughnut type, were installed to compare the performance of both types of equipment over an extended period.The plant has been operating in parallel for three years and the results show that the performance of the columns is excellent: the extraction yield is similar to the 4 mixer-settlers in series - about 98%, the entrainment of solvent is lower, there are less mechanical failures, less problems with crud, smaller solvent losses and the operation is simpler. The results convinced WMC to install an additional 10 BPC's for the expansion of their uranium plant. These columns were successfully commissioned early 1999. This paper includes quantitative comparison of both types of equipment. (author)

  17. An I/Q mixer with an integrated differential quadrature all-pass filter for on-chip quadrature LO signal generation

    International Nuclear Information System (INIS)

    Amin, Najam Muhammad; Wang Zhigong; Li Zhiqun

    2015-01-01

    A down-conversion in-phase/quadrature (I/Q) mixer employing a folded-type topology, integrated with a passive differential quadrature all-pass filter (D-QAF), in order to realize the final down-conversion stage of a 60 GHz receiver architecture is presented in this work. Instead of employing conventional quadrature generation techniques such as a polyphase filter or a frequency divider for the local oscillator (LO) of the mixer, a passive D-QAF structure is employed. Fabricated in a 65 nm CMOS process, the mixer exhibits a voltage gain of 7–8 dB in an intermediate frequency (IF) band ranging from 10 MHz–1.75 GHz. A fixed LO frequency of 12 GHz is used to down-convert a radio frequency (RF) band of 10.25–13.75 GHz. The mixer displays a third order input referred intercept point (IIP 3 ) ranging from −8.75 to −7.37 dBm for a fixed IF frequency of 10 MHz and a minimum single-sideband noise figure (SSB-NF) of 11.3 dB. The mixer draws a current of 6 mA from a 1.2 V supply voltage dissipating a power of 7.2 mW. (paper)

  18. Computational Fluid Dynamics and Experimental Studies of a New Mixing Element in a Static Mixer as a Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Konopacki Maciej

    2015-03-01

    Full Text Available The main aim of this work is to study the thermal efficiency of a new type of a static mixer and to analyse the flow and temperature patterns and heat transfer efficiency. The measurements were carried out for the static mixer equipped with a new mixing insert. The heat transfer enhancement was determined by measuring the temperature profiles on each side of the heating pipe as well as the temperature field inside the static mixer. All experiments were carried out with varying operating parameters for four liquids: water, glycerol, transformer oil and an aqueous solution of molasses. Numerical CFD simulations were carried out using the two-equation turbulence k-ω model, provided by ANSYS Workbench 14.5 software. The proposed CFD model was validated by comparing the predicted numerical results against experimental thermal database obtained from the investigations. Local and global convective heat transfer coefficients and Nusselt numbers were detrmined. The relationship between heat transfer process and hydrodynamics in the static mixer was also presented. Moreover, a comparison of the thermal performance between the tested static mixer and a conventional empty tube was carried out. The relative enhancement of heat transfer was characterised by the rate of relative heat transfer intensification.

  19. Abnormal activation of the occipital lobes during emotion picture processing in major depressive disorder patients

    Science.gov (United States)

    Li, Jianying; Xu, Cheng; Cao, Xiaohua; Gao, Qiang; Wang, Yan; Wang, Yanfang; Peng, Juyi; Zhang, Kerang

    2013-01-01

    A large number of studies have demonstrated that depression patients have cognitive dysfunction. With recently developed brain functional imaging, studies have focused on changes in brain function to investigate cognitive changes. However, there is still controversy regarding abnormalities in brain functions or correlation between cognitive impairment and brain function changes. Thus, it is important to design an emotion-related task for research into brain function changes. We selected positive, neutral, and negative pictures from the International Affective Picture System. Patients with major depressive disorder were asked to judge emotion pictures. In addition, functional MRI was performed to synchronously record behavior data and imaging data. Results showed that the total correct rate for recognizing pictures was lower in patients compared with normal controls. Moreover, the consistency for recognizing pictures for depressed patients was worse than normal controls, and they frequently recognized positive pictures as negative pictures. The consistency for recognizing pictures was negatively correlated with the Hamilton Depression Rating Scale. Functional MRI suggested that the activation of some areas in the frontal lobe, temporal lobe, parietal lobe, limbic lobe, and cerebellum was enhanced, but that the activation of some areas in the frontal lobe, parietal lobe and occipital lobe was weakened while the patients were watching positive and neutral pictures compared with normal controls. The activation of some areas in the frontal lobe, temporal lobe, parietal lobe, and limbic lobe was enhanced, but the activation of some areas in the occipital lobe were weakened while the patients were watching the negative pictures compared with normal controls. These findings indicate that patients with major depressive disorder have negative cognitive disorder and extensive brain dysfunction. Thus, reduced activation of the occipital lobe may be an initiating factor for

  20. Micro-mixer/combustor

    KAUST Repository

    Badra, Jihad Ahmad

    2014-09-18

    A micro-mixer/combustor to mix fuel and oxidant streams into combustible mixtures where flames resulting from combustion of the mixture can be sustained inside its combustion chamber is provided. The present design is particularly suitable for diffusion flames. In various aspects the present design mixes the fuel and oxidant streams prior to entering a combustion chamber. The combustion chamber is designed to prevent excess pressure to build up within the combustion chamber, which build up can cause instabilities in the flame. A restriction in the inlet to the combustion chamber from the mixing chamber forces the incoming streams to converge while introducing minor pressure drop. In one or more aspects, heat from combustion products exhausted from the combustion chamber may be used to provide heat to at least one of fuel passing through the fuel inlet channel, oxidant passing through the oxidant inlet channel, the mixing chamber, or the combustion chamber. In one or more aspects, an ignition strip may be positioned in the combustion chamber to sustain a flame without preheating.

  1. FDC Mentor-Mentee Mixer Breaks the Ice Between Investigators and Trainees | Poster

    Science.gov (United States)

    The Frederick Diversity Committee’s mentor-mentee mixer gave research trainees, senior investigators, scientists, and administrative staff a chance to meet and mingle over refreshments and games following the Spring Research Festival.

  2. Process design of a new injection method of liquid CO2 at the intermediate depths in the ocean using a static mixer

    International Nuclear Information System (INIS)

    Tajima, Hideo; Yamasaki, Akihiro; Kiyono, Fumio

    2005-01-01

    Process design for a new injection method of liquid CO 2 using a static mixer was conducted based on laboratory experimental results on the formation process of liquid CO 2 drops covered with hydrate film by a Kenics-type static mixer, and numerical simulation of the liquid CO 2 drops at 500 and 1500 m. The Sauter Mean Diameter (SMD) of the liquid CO 2 drops covered with hydrate film was dramatically decreased with the use of the static mixer; empirical equations were obtained for the SMD, and also the maximum and minimum diameters of the liquid CO 2 drops for a given flow velocity (Weber number, We). The ascending and dissolving behavior of a liquid CO 2 drop with hydrate released in the ocean at an intermediate depth was numerically simulated, and the maximum drop diameter to avoid evaporation of the drop before complete dissolution was estimated. Based on these results, scaling up of the static mixer was conducted by assuming a disposal process of CO 2 emitted from a 100-MW thermal power plant, and the mixer diameter was determined as a function of the given SMD. Moreover, the power consumption of the static mixer was evaluated and found to be almost negligible. (author)

  3. Terahertz hot electron bolometer waveguide mixers for GREAT

    OpenAIRE

    Pütz, P.; Honingh, C. E.; Jacobs, K.; Justen, M.; Schultz, M.; Stutzki, J.

    2012-01-01

    Supplementing the publications based on the first-light observations with the German Receiver for Astronomy at Terahertz frequencies (GREAT) on SOFIA, we present background information on the underlying heterodyne detector technology. We describe the superconducting hot electron bolometer (HEB) detectors that are used as frequency mixers in the L1 (1400 GHz), L2 (1900 GHz), and M (2500 GHz) channels of GREAT. Measured performance of the detectors is presented and background information on the...

  4. Semantic memory is impaired in patients with unilateral anterior temporal lobe resection for temporal lobe epilepsy.

    Science.gov (United States)

    Lambon Ralph, Matthew A; Ehsan, Sheeba; Baker, Gus A; Rogers, Timothy T

    2012-01-01

    Contemporary clinical and basic neuroscience studies have increasingly implicated the anterior temporal lobe regions, bilaterally, in the formation of coherent concepts. Mounting convergent evidence for the importance of the anterior temporal lobe in semantic memory is found in patients with bilateral anterior temporal lobe damage (e.g. semantic dementia), functional neuroimaging and repetitive transcranial magnetic stimulation studies. If this proposal is correct, then one might expect patients with anterior temporal lobe resection for long-standing temporal lobe epilepsy to be semantically impaired. Such patients, however, do not present clinically with striking comprehension deficits but with amnesia and variable anomia, leading some to conclude that semantic memory is intact in resection for temporal lobe epilepsy and thus casting doubt over the conclusions drawn from semantic dementia and linked basic neuroscience studies. Whilst there is a considerable neuropsychological literature on temporal lobe epilepsy, few studies have probed semantic memory directly, with mixed results, and none have undertaken the same type of systematic investigation of semantic processing that has been conducted with other patient groups. In this study, therefore, we investigated the semantic performance of 20 patients with resection for chronic temporal lobe epilepsy with a full battery of semantic assessments, including more sensitive measures of semantic processing. The results provide a bridge between the current clinical observations about resection for temporal lobe epilepsy and the expectations from semantic dementia and other neuroscience findings. Specifically, we found that on simple semantic tasks, the patients' accuracy fell in the normal range, with the exception that some patients with left resection for temporal lobe epilepsy had measurable anomia. Once the semantic assessments were made more challenging, by probing specific-level concepts, lower frequency

  5. Photonics-Based Microwave Image-Reject Mixer

    Directory of Open Access Journals (Sweden)

    Dan Zhu

    2018-03-01

    Full Text Available Recent developments in photonics-based microwave image-reject mixers (IRMs are reviewed with an emphasis on the pre-filtering method, which applies an optical or electrical filter to remove the undesired image, and the phase cancellation method, which is realized by introducing an additional phase to the converted image and cancelling it through coherent combination without phase shift. Applications of photonics-based microwave IRM in electronic warfare, radar systems and satellite payloads are described. The inherent challenges of implementing photonics-based microwave IRM to meet specific requirements of the radio frequency (RF system are discussed. Developmental trends of the photonics-based microwave IRM are also discussed.

  6. Structural analysis: Flexible receiver yoke brace for the 241SY101 mixer pump

    International Nuclear Information System (INIS)

    Jones, K.M.

    1994-01-01

    This report documents the structural analysis of the flexible-receiver yoke brace that will be used to maintain the mixer pump lifting yoke in a vertical position during the removal of the mixer pump from waste tank 241SY101. During the removal process, the crane is connected to a lifting yoke which is attached to the lifting on the mounting flange of the mixer pump. The pump then can be lifted from the tank. At one point in the removal procedure, the crane will be disconnected from the lifting yoke. At this time, it is possible for the lifting yoke to rotate around the pinned connection between it and the pump if it is subjected to a horizontal load. To prevent the rotation of the lifting yoke, the yoke brace was designed to maintain the yoke in a vertical position while it is disconnected from the crane. This analysis addressed the adequacy of the yoke brace to provide support for the lifting yoke during high winds and a seismic event. The results of this analysis show that, when subjected to a combined design wind and seismic load, the yoke brace design is acceptable to maintain the lifting yoke in a vertical position when the yoke is disconnected from the crane

  7. Design of Ka-band antipodal finline mixer and detector

    International Nuclear Information System (INIS)

    Yao Changfei; Xu Jinping; Chen Mo

    2009-01-01

    This paper mainly discusses the analysis and design of a finline single-ended mixer and detector. In the circuit, for the purpose of eliminating high-order resonant modes and improving transition loss, metallic via holes are implemented along the mounting edge of the substrate embedded in the split-block of the WG-finline-microstrip transition. Meanwhile, a Ka band slow-wave and bandstop filter, which represents a reactive termination, is designed for the utilization of idle frequencies and operation frequencies energy. Full-wave analysis is carried out to optimize the input matching network of the mixer and the detector circuit using lumped elements to model the nonlinear diode. The exported S-matrix of the optimized circuit is used for conversion loss and voltage sensitivity analysis. The lowest measured conversion loss is 3.52 dB at 32.2 GHz; the conversion loss is flat and less than 5.68 dB in the frequency band of 29-34 GHz. The highest measured zero-bias voltage sensitivity is 1450 mV/mW at 38.6 GHz, and the sensitivity is better than 1000 mV/mW in the frequency band of 38-40 GHz.

  8. Design of a ×4 subharmonic sub-millimeter wave diode mixer, based on an analytic expression for small-signal conversion admittance parameters

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus Schandorph; Johansen, Tom Keinicke; Krozer, Viktor

    2013-01-01

    Instead of using frequency multipliers before a fundamental mixer, subharmonic mixers can be used. In order to develop novel subharmonic mixer architectures it is necessary to know the exact signal phase at the nonlinear element. The purpose of this paper is to generalize the description of the s....... With an RF frequency of 640 GHz, this design achieves a conversion gain of −13.5 dB with a LO-power of only −2.5 dBm....

  9. Modeling and Optimization of a High-Tc Hot-Electron Superconducting Mixer for Terahertz Applicaitons

    Science.gov (United States)

    Karasik, B. S.; McGrath, W. R.; Gaidis, M. C.; Burns, M. J.; Kleinsasser, A. W.; Delin, K. A.; Vasquez, R. P.

    1996-01-01

    The development of a YBa(sub 2)Cu(sub 3)O(sub 7-(kronecker delta))(YBCO) hot-electron bolometer (HEB) quasioptical mixer for a 2.5 heterodyne receiver is discussed. The modeled device is a submicron bridge made from a 10 nm thick film on a high thermal conductance substrate. The mixer performance expected for this device is analyzed in the framework of a two-temperature model which includes heating both of the electrons and the lattice. Also, the contribution of heat diffusion from the film through the substrate and from the film to the normal metal contacts is evaluated....a single sideband temperature of less than 2000k is predicted.

  10. Open source laboratory sample rotator mixer and shaker

    Directory of Open Access Journals (Sweden)

    Karankumar C. Dhankani

    2017-04-01

    Full Text Available An open-source 3-D printable laboratory sample rotator mixer is developed here in two variants that allow users to opt for the level of functionality, cost saving and associated complexity needed in their laboratories. First, a laboratory sample rotator is designed and demonstrated that can be used for tumbling as well as gentle mixing of samples in a variety of tube sizes by mixing them horizontally, vertically, or any position in between. Changing the mixing angle is fast and convenient and requires no tools. This device is battery powered and can be easily transported to operate in various locations in a lab including desktops, benches, clean hoods, chemical hoods, cold rooms, glove boxes, incubators or biological hoods. Second, an on-board Arduino-based microcontroller is incorporated that adds the functionality of a laboratory sample shaker. These devices can be customized both mechanically and functionally as the user can simply select the operation mode on the switch or alter the code to perform custom experiments. The open source laboratory sample rotator mixer can be built by non-specialists for under US$30 and adding shaking functionality can be done for under $20 more. Thus, these open source devices are technically superior to the proprietary commercial equipment available on the market while saving over 90% of the costs.

  11. A planar microfluidic mixer based on logarithmic spirals

    International Nuclear Information System (INIS)

    Scherr, Thomas; Nandakumar, Krishnaswamy; Quitadamo, Christian; Tesvich, Preston; Park, Daniel Sang-Won; Hayes, Daniel; Monroe, W Todd; Tiersch, Terrence; Choi, Jin-Woo

    2012-01-01

    A passive, planar micromixer design based on logarithmic spirals is presented. The device was fabricated using polydimethylsiloxane soft photolithography techniques, and mixing performance was characterized via numerical simulation and fluorescent microscopy. Mixing efficiency initially declined as the Reynolds number increased, and this trend continued until a Reynolds number of 15 where a minimum was reached at 53%. Mixing efficiency then began to increase reaching a maximum mixing efficiency of 86% at Re = 67. Three-dimensional (3D) simulations of fluid mixing in this design were compared to other planar geometries such as the Archimedes spiral and Meandering-S mixers. The implementation of logarithmic curvature offers several unique advantages that enhance mixing, namely a variable cross-sectional area and a logarithmically varying radius of curvature that creates 3D Dean vortices. These flow phenomena were observed in simulations with multilayered fluid folding and validated with confocal microscopy. This design provides improved mixing performance over a broader range of Reynolds numbers than other reported planar mixers, all while avoiding external force fields, more complicated fabrication processes and the introduction of flow obstructions or cavities that may unintentionally affect sensitive or particulate-containing samples. Due to the planar design requiring only single-step lithographic features, this compact geometry could be easily implemented into existing micro-total analysis systems requiring effective rapid mixing. (paper)

  12. The frontal lobes and inhibitory function

    International Nuclear Information System (INIS)

    Konishi, Seiki

    2011-01-01

    Neuropsychological studies using traditional tasks of inhibitory functions, such as the Wisconsin card sorting test (WCST) and the Go/No-Go Task have revealed that the frontal lobe is responsible for several types of inhibitory functions. However, the detailed psychological nature of the inhibitory functions and the precise location of their critical foci within the frontal lobe remain to be investigated. Functional magnetic resonance imaging provides spatial and temporal resolution that allowed us to illuminate at least 4 frontal regions involved in inhibitory functions: the dorsolateral, ventrolateral, and rostral parts of the frontal lobe and the presupplementary motor area (preSMA). The ventrolateral part of the frontal lobe in the right hemisphere was activated during response inhibition. The preSMA in the left hemisphere was activated during inhibition of proactive interference immediately after the dimension changes of the WCST. The rostral part of the frontal lobe in the left hemisphere was activated during inhibition long after the dimension changes. The dorsolateral part of the frontal lobe in the left hemisphere was activated at the dimension changes in the first time, but not in the second time. These findings provide clues to our understanding of functional differentiation of inhibitory functions and their localization in the frontal lobe. (author)

  13. The BLIXER, a Wideband Balun-LNA-I/Q-Mixer Topology

    NARCIS (Netherlands)

    Blaakmeer, S.C.; Klumperink, Eric A.M.; Leenaerts, Domine M.W.; Nauta, Bram

    2008-01-01

    Abstract—This paper proposes to merge an I/Q current-commutating mixer with a noise-canceling balun-LNA. To realize a high bandwidth, the real part of the impedance of all RF nodes is kept low, and the voltage gain is not created at RF but in baseband where capacitive loading is no problem. Thus a

  14. Phase-locking of a terahertz solid-state source using a superconducting hot-electron bolometer mixer

    International Nuclear Information System (INIS)

    Miao, W; Zhang, W; Zhou, K M; Li, S L; Zhang, K; Duan, W Y; Yao, Q J; Shi, S C

    2013-01-01

    We report on a scheme whereby the local-oscillator (LO) of a THz heterodyne receiver can be phase-locked by the mixer of the heterodyne receiver. This scheme is demonstrated for the phase-locking of an 847.6 GHz Gunn oscillator and multiplier chain combined source with a superconducting hot-electron bolometer (HEB) mixer. We show that with this technique the phase-locked beat signal can reach a signal-to-noise ratio higher than 70 dB in a resolution bandwidth (RBW) of 1 Hz. This phase-locking scheme should find good use in THz heterodyne spectrometers. (paper)

  15. Clinical study on temporal lobe epilepsy in childhood caused by temporal lobe space occupying lesions

    International Nuclear Information System (INIS)

    Matsuura, Mariko; Oguni, Hirokazu; Funatsuka, Makoto; Osawa, Makiko; Yamane, Fumitaka; Hori, Tomokatsu; Shimizu, Hiroyuki

    2008-01-01

    We studied the clinicoelectrical and neuroimaging features of 11 patients with symptomatic temporal lobe epilepsy (TLE) caused by temporal lobe space occupying lesions (SOLs), and compared its characteristics with those of 19 mesial TLE (MTLE) patients. Brain MRI demonstrated SOLs in the mesiotemporal lobe in 9, and laterotemporal lobe in the remaining 2 patients. Ten of the 11 patients successfully underwent surgery, which revealed tumors in 7 and focal cortical dysplasia in 3 patients. Comparisons of the clinical features between those with space occupying TLE (SOTLE) and MTLE showed that both conditions shared the same clinical seizure manifestations such as gastric uprising sensation or ictal fear and a favorable response to surgery. However, the patients with SOTLE had fewer febrile convulsion, and more frequent seizure recurrences as well as TLE EEG discharges and associations of the monophasic clinical course than those with MTLE. In addition, the MRI findings were characterized by unilateral hippocampal atrophy in MTLE and expanding or SOLs in the SOTLE group. Children with complex partial seizures of suspected temporal lobe origin should undergo extensive neuroimaging evaluation. (author)

  16. Modeling emulsification processes in rotary-disk mixers

    Science.gov (United States)

    Laponov, S. V.; Shulaev, N. S.; Ivanov, S. P.; Bondar', K. E.; Suleimanov, D. F.

    2017-10-01

    This article presents the experimental studies results of emulsification processes in liquid-liquid systems in rotary-disk mixers, allowing regulating the distribution of dispersed particles by changing the process conditions and the ratio of the dispersed phase. It is shown that with the increase of mixer’s revolutions per minute (RPM), both the size of dispersed particles and the deviation of dispersed particles sizes from the average decrease. The increase of the dispersed particles part results in the increase of particles average sizes at the current energy consumption. Discovered relationships can be used in the design of industrial equipment and laboratory research.

  17. Mismatch between the eye and the optic lobe in the giant squid.

    Science.gov (United States)

    Liu, Yung-Chieh; Liu, Tsung-Han; Yu, Chun-Chieh; Su, Chia-Hao; Chiao, Chuan-Chin

    2017-07-01

    Giant squids ( Architeuthis ) are a legendary species among the cephalopods. They live in the deep sea and are well known for their enormous body and giant eyes. It has been suggested that their giant eyes are not adapted for the detection of either mates or prey at distance, but rather are best suited for monitoring very large predators, such as sperm whales, at distances exceeding 120 m and at a depth below 600 m (Nilsson et al. 2012 Curr. Biol. 22 , 683-688. (doi:10.1016/j.cub.2012.02.031)). However, it is not clear how the brain of giant squids processes visual information. In this study, the optic lobe of a giant squid ( Architeuthis dux , male, mantle length 89 cm), which was caught by local fishermen off the northeastern coast of Taiwan, was scanned using high-resolution magnetic resonance imaging in order to examine its internal structure. It was evident that the volume ratio of the optic lobe to the eye in the giant squid is much smaller than that in the oval squid ( Sepioteuthis lessoniana ) and the cuttlefish ( Sepia pharaonis ). Furthermore, the cell density in the cortex of the optic lobe is significantly higher in the giant squid than in oval squids and cuttlefish, with the relative thickness of the cortex being much larger in Architeuthis optic lobe than in cuttlefish. This indicates that the relative size of the medulla of the optic lobe in the giant squid is disproportionally smaller compared with these two cephalopod species. This morphological study of the giant squid brain, though limited only to the optic lobe, provides the first evidence to support that the optic lobe cortex, the visual information processing area in cephalopods, is well developed in the giant squid. In comparison, the optic lobe medulla, the visuomotor integration centre in cephalopods, is much less developed in the giant squid than other species. This finding suggests that, despite the giant eye and a full-fledged cortex within the optic lobe, the brain of giant

  18. Numerical study of fluid motion in bioreactor with two mixers

    Energy Technology Data Exchange (ETDEWEB)

    Zheleva, I., E-mail: izheleva@uni-ruse.bg [Department of Heat Technology, Hydraulics and Ecology, Angel Kanchev University of Rousse, 8 Studentska str., 7017 Rousse (Bulgaria); Lecheva, A., E-mail: alecheva@uni-ruse.bg [Department of Mathematics, Angel Kanchev University of Rousse, 8 Studentska str., 7017 Rousse (Bulgaria)

    2015-10-28

    Numerical study of hydrodynamic laminar behavior of a viscous fluid in bioreactor with multiple mixers is provided in the present paper. The reactor is equipped with two disk impellers. The fluid motion is studied in stream function-vorticity formulation. The calculations are made by a computer program, written in MATLAB. The fluid structure is described and numerical results are graphically presented and commented.

  19. Unified Frequency-Domain Analysis of Switched-Series-RC Passive Mixers and Samplers

    NARCIS (Netherlands)

    Soer, M.C.M.; Klumperink, Eric A.M.; de Boer, Pieter-Tjerk; van Vliet, Frank Edward; Nauta, Bram

    2010-01-01

    Abstract—A wide variety of voltage mixers and samplers are implemented with similar circuits employing switches, resistors, and capacitors. Restrictions on duty cycle, bandwidth, or output frequency are commonly used to obtain an analytical expression for the response of these circuits. This paper

  20. Determinants of brain metabolism changes in mesial temporal lobe epilepsy.

    Science.gov (United States)

    Chassoux, Francine; Artiges, Eric; Semah, Franck; Desarnaud, Serge; Laurent, Agathe; Landre, Elisabeth; Gervais, Philippe; Devaux, Bertrand; Helal, Ourkia Badia

    2016-06-01

    hypometabolism in MTLE. Compensatory mechanisms reflected by a relative hypermetabolism in the nonepileptic temporal lobe and in extratemporal areas seem more efficient in LHS and in female patients, whereas long duration, late onset of epilepsy, and high seizure frequency may reduce these adaptive changes. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  1. A simple three-dimensional-focusing, continuous-flow mixer for the study of fast protein dynamics.

    Science.gov (United States)

    Burke, Kelly S; Parul, Dzmitry; Reddish, Michael J; Dyer, R Brian

    2013-08-07

    We present a simple, yet flexible microfluidic mixer with a demonstrated mixing time as short as 80 μs that is widely accessible because it is made of commercially available parts. To simplify the study of fast protein dynamics, we have developed an inexpensive continuous-flow microfluidic mixer, requiring no specialized equipment or techniques. The mixer uses three-dimensional, hydrodynamic focusing of a protein sample stream by a surrounding sheath solution to achieve rapid diffusional mixing between the sample and sheath. Mixing initiates the reaction of interest. Reactions can be spatially observed by fluorescence or absorbance spectroscopy. We characterized the pixel-to-time calibration and diffusional mixing experimentally. We achieved a mixing time as short as 80 μs. We studied the kinetics of horse apomyoglobin (apoMb) unfolding from the intermediate (I) state to its completely unfolded (U) state, induced by a pH jump from the initial pH of 4.5 in the sample stream to a final pH of 2.0 in the sheath solution. The reaction time was probed using the fluorescence of 1-anilinonaphthalene-8-sulfonate (1,8-ANS) bound to the folded protein. We observed unfolding of apoMb within 760 μs, without populating additional intermediate states under these conditions. We also studied the reaction kinetics of the conversion of pyruvate to lactate catalyzed by lactate dehydrogenase using the intrinsic tryptophan emission of the enzyme. We observe sub-millisecond kinetics that we attribute to Michaelis complex formation and loop domain closure. These results demonstrate the utility of the three-dimensional focusing mixer for biophysical studies of protein dynamics.

  2. 30 GHz monolithic balanced mixers using an ion-implanted FET-compatible 3-inch GaAs wafer process technology

    Science.gov (United States)

    Bauhahn, P.; Contolatis, A.; Sokolov, V.; Chao, C.

    1986-01-01

    An all ion-implanted Schottky barrier mixer diode which has a cutoff frequency greater than 1000 GHz has been developed. This new device is planar and FET-compatible and employs a projection lithography 3-inch wafer process. A Ka-band monolithic balanced mixer based on this device has been designed, fabricated and tested. A conversion loss of 8 dB has been measured with a LO drive of 10 dBm at 30 GHz.

  3. A novel microfluidic mixer based on dual-hydrodynamic focusing for interrogating the kinetics of DNA-protein interaction.

    Science.gov (United States)

    Li, Ying; Xu, Fei; Liu, Chao; Xu, Youzhi; Feng, Xiaojun; Liu, Bi-Feng

    2013-08-21

    Kinetic measurement of biomacromolecular interaction plays a significant role in revealing the underlying mechanisms of cellular activities. Due to the small diffusion coefficient of biomacromolecules, it is difficult to resolve the rapid kinetic process with traditional analytical methods such as stopped-flow or laminar mixers. Here, we demonstrated a unique continuous-flow laminar mixer based on microfluidic dual-hydrodynamic focusing to characterize the kinetics of DNA-protein interactions. The time window of this mixer for kinetics observation could cover from sub-milliseconds to seconds, which made it possible to capture the folding process with a wide dynamic range. Moreover, the sample consumption was remarkably reduced to <0.55 μL min⁻¹, over 1000-fold saving in comparison to those reported previously. We further interrogated the interaction kinetics of G-quadruplex and the single-stranded DNA binding protein, indicating that this novel micromixer would be a useful approach for analyzing the interaction kinetics of biomacromolecules.

  4. Scale-up of mixer-settler for uranium extraction; Determinacao das relacoes de `scale-up` em misturador-decantador tipo caixa utilizado na extracao de uranio

    Energy Technology Data Exchange (ETDEWEB)

    Santana, A.O. de

    1990-05-01

    The aim of this work was to obtain scale-up relations for a box type mixer-settler used in uranium extraction process for chloridric leaches. Three box type units with different sizes and with the same geometry were used for scale-up of the mixer. The correlation between extraction rate and specific power input, D/T ratio (stirrer diameter/mixer length) and residence time were experimentally obtained. The results showed that the extraction increases with power input for a constant value of D/T equal to 1/3, remaining however independent from mixer sizes for a specific value of power input. This behavior was observed for power input values ranging from 100 to 750 w/m{sup 9}. (author). 23 refs, 22 figs, 23 tabs.

  5. Fabrication of High-T(sub c) Hot-Electron Bolometric Mixers for Terahertz Applications

    Science.gov (United States)

    Burns, M. J.; Kleinsasser, A. W.; Delin, K. A.; Vasquez, R. P.; Karasik, B. S.; McGrath, W. R.; Gaidis, M. C.

    1996-01-01

    Superocnducting hot-electron bolometers (HEB) represent a promising candidate for heterodyne mixing at frequencies exceeding 1 THz. Nb HEB mixers offer performance competitive with tunnel junctions without the frequency limit imposed by the superconducting energy gap.

  6. Experiments on Josephson mixers for heterodyne reception at 0.3 mm wavelength

    International Nuclear Information System (INIS)

    Blaney, T.G.; Knight, D.J.E.

    1974-01-01

    A point contact Josephson junction was investigated as a heterodyne mixer at 337 μm. The conversion efficiency reached about -32 dB using a laser local oscillator and about -42 dB using 9th or 12th harmonic mixing with a klystron

  7. Analysis of a High-Tc Hot-Electron Superconducting Mixer for Terahertz Applications

    Science.gov (United States)

    Karasik, B. S.; McGrath, W. R.; Gaidis, M. C.

    1996-01-01

    The prospects of a YBa2Cu3O7(delta)(YBCO) hot-electron bolometer (HEB) mixer for a THz heterodyne receiver is discussed. The modeled device is a submicron bridge made from a 10 nm thick film on a high thermal conductance substrate.

  8. Verbal memory after temporal lobe epilepsy surgery in children: Do only mesial structures matter?

    Science.gov (United States)

    Law, Nicole; Benifla, Mony; Rutka, James; Smith, Mary Lou

    2017-02-01

    Previous findings have been mixed regarding verbal memory outcome after left temporal lobectomy in children, and there are few studies comparing verbal memory change after lateral versus mesial temporal lobe resections. We compared verbal memory outcome associated with sparing or including the mesial structures in children who underwent left or right temporal lobe resection. We also investigated predictors of postsurgical verbal memory change. We retrospectively assessed verbal memory change approximately 1 year after unilateral temporal lobe epilepsy surgery using a list learning task. Participants included 23 children who underwent temporal lobe surgery with sparing of the mesial structures (13 left), and 40 children who had a temporal lobectomy that included resection of mesial structures (22 left). Children who underwent resection from the left lateral and mesial temporal lobe were the only group to show decline in verbal memory. Furthermore, when we considered language representation in the left temporal resection group, patients with left language representation and spared mesial structures showed essentially no change in verbal memory from preoperative to follow-up, whereas those with left language representation and excised mesial structures showed a decline. Postoperative seizure status had no effect on verbal memory change in children after left temporal lobe surgery. Finally, we found that patients with intact preoperative verbal memory experienced a significant decline compared to those with below average preoperative verbal memory. Our findings provide evidence of significant risk factors for verbal memory decline in children, specific to left mesial temporal lobe epilepsy. Children who undergo left temporal lobe surgery that includes mesial structures may be most vulnerable for verbal memory decline, especially when language representation is localized to the left hemisphere and when preoperative verbal memory is intact. Wiley Periodicals, Inc.

  9. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  10. Double Modulation Scheme for Switching Mixers Controlled by Sigma-Delta Modulators

    DEFF Research Database (Denmark)

    Nielsen, Per Asbeck; Fallesen, Carsten

    1998-01-01

    . This modification can be carried out on a large variety of mixers including the above mentioned. Although the principle was meant to be used to down convert analog signals, the principle is general and can be used in digital circuits too. This paper verifies the new mixing scheme and compares it to the traditional...

  11. Self Oscillating Mixer with Dielectric Resonator for Low Noise Block Application

    Directory of Open Access Journals (Sweden)

    Endon Bharata

    2011-08-01

    Full Text Available In this paper, the development of a self oscillating mixer (SOM as part of a low noise block (LNB for a satellite television receiver is investigated numerically and experimentally. In contrast to other mixers, the developed SOM requires no separate local oscillator as it generates own local oscillator signal. The SOM is developed using a monolithic microwave integrated circuit (MMIC comprised of two bipolar transistors coupled as a Darlington pair and a dielectric resonator to establish a local oscillator signal. The SOM is designed to oscillate at 3.62GHz driven from 50W signal generator. The prototype of SOM is fabricated on a dielectric substrate of glass-reinforced hydrocarbon/ceramic lamination (RO4350B board which has a thickness of 0.762mm and relative permittivity of 3.66. The prototype is then characterized experimentally and exhibits a conversion gain of 8dB with the input and output voltage standing wave ratio (VSWR less than 2 across the 2520MHz to 2670MHz operating frequency band.

  12. Hepatocellular carcinoma in Riedel's lobe.

    Science.gov (United States)

    Zamfir, R; Braşoveanu, V; Boroş, M; Herlea, V; Popescu, I

    2008-01-01

    We present a rare case of 65-year female with right abdominal mass and abdominal discomfort; a combination of Doppler ultrasonography, computed tomography and laparotomy was utilized to make a diagnosis of tumoral Riedel's lobe. In our case, laparotomy with resection of Riedel's lobe was the proper therapeutical solution.

  13. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  14. 241-SY-101 mixer pump lifetime expectancy. Final report

    International Nuclear Information System (INIS)

    Shaw, C.P.

    1995-01-01

    The purpose of WHC-SD-WM-TI-726, Rev. 0 241-SY-101 Mixer Pump Lifetime Expectancy is to determine a best estimate of the mean lifetime of non-repairable (located in the waste) essential features of the hydrogen mitigation mixer pump presently installed in 101-SY. The estimated mean lifetime is 9.1 years. This report does not demonstrate operation of the entire pump assembly within the Tank Farm ''safety envelope''. It was recognized by the Defense Nuclear Facilities Safety Board (DNFSB) this test pump was not specifically designed for long term service in tank 101-SY. In June 95 the DNFSB visited Hanford and ask the question, ''how long will this test pump last and how will the essential features fail?'' During the 2 day meeting with the DNFSB it was discussed and defined within the meeting just exactly what essential features of the pump must operate. These essential features would allow the pump to operate for the purpose of extending the window for replacement. Operating with only essential features would definitely be outside the operating safety envelope and would require a waiver. There are three essential features: 1. The pump itself (i.e. the impeller and motor) must operate 2. Nozzles and discharges leg must remain unplugged 3. The pump can be re-aimed, new waste targeted, even if manually

  15. Arterial supply of the thoracic lobes of the thymus in dogs of the Great Dane race.

    Directory of Open Access Journals (Sweden)

    Rosana Marques Silva

    2007-09-01

    Full Text Available The origins, numbers and type of arterial branches responsible for the blood supply of thoracic lobes of the thymus were studied in 28 stillborn dogs of the Great Dane, of which 18 were males and 10 were females. The arterial systems of these animals were filled with aqueous solution of Neoprene Latex “450”, 50%. After, the specimens were fixed in 10% formaldehyde aqueous solution. The lobes of the thymus were supplied by direct or indirect arterial branches coming from the right and left internal thoracic arteries, pericardiacophrenicas arteries, right and left costocervicais trunks, and left subclavian artery. The left subclavian artery and brachiocephalic trunk emitted direct branches towards the left thoracic lobe of the thymus.

  16. Microsurgical anatomy of the central lobe.

    Science.gov (United States)

    Frigeri, Thomas; Paglioli, Eliseu; de Oliveira, Evandro; Rhoton, Albert L

    2015-03-01

    The central lobe consists of the pre- and postcentral gyri on the lateral surface and the paracentral lobule on the medial surface and corresponds to the sensorimotor cortex. The objective of the present study was to define the neural features, craniometric relationships, arterial supply, and venous drainage of the central lobe. Cadaveric hemispheres dissected using microsurgical techniques provided the material for this study. The coronal suture is closer to the precentral gyrus and central sulcus at its lower rather than at its upper end, but they are closest at a point near where the superior temporal line crosses the coronal suture. The arterial supply of the lower two-thirds of the lateral surface of the central lobe was from the central, precentral, and anterior parietal branches that arose predominantly from the superior trunk of the middle cerebral artery. The medial surface and the superior third of the lateral surface were supplied by the posterior interior frontal, paracentral, and superior parietal branches of the pericallosal and callosomarginal arteries. The venous drainage of the superior two-thirds of the lateral surface and the central lobe on the medial surface was predominantly through the superior sagittal sinus, and the inferior third of the lateral surface was predominantly through the superficial sylvian veins to the sphenoparietal sinus or the vein of Labbé to the transverse sinus. The pre- and postcentral gyri and paracentral lobule have a morphological and functional anatomy that differentiates them from the remainder of their respective lobes and are considered by many as a single lobe. An understanding of the anatomical relationships of the central lobe can be useful in preoperative planning and in establishing reliable intraoperative landmarks.

  17. Confabulation and memory impairments following frontal lobe lesions

    OpenAIRE

    Turner, Martha

    2005-01-01

    Neuroimaging studies have provided considerable evidence for frontal lobe involvement in memory processing. Memory impairments arc also frequently reported in patients with frontal lobe lesions. However detailed anatomical localisation is rare, making integration of lesion and imaging findings difficult. An investigation of the functional and anatomical contributions of the frontal lobes to memory was conducted in 42 patients with frontal lobe lesions, examining memory processes identified in...

  18. An InP HBT sub-harmonic mixer for E-band wireless communication

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor

    2010-01-01

    This paper reports on a novel balanced HBT subharmonic mixer (SHM) for E-band wireless communication. An LO spiral type Marchand balun is integrated with the SHM. The SHM has been fabricated in a InP double heterojunction bipolar transistor (DHBT) circuit-oriented technology with fT /fmax = 180GHz...

  19. Design and characterization of downconversion mixers and the on-chip calibration techniques for monolithic direct conversion radio receivers

    OpenAIRE

    Kivekäs, Kalle

    2002-01-01

    This thesis consists of eight publications and an overview of the research topic, which is also a summary of the work. The research described in this thesis is focused on the design of downconversion mixers and direct conversion radio receivers for UTRA/FDD WCDMA and GSM standards. The main interest of the work is in the 1-3 GHz frequency range and in the Silicon and Silicon-Germanium BiCMOS technologies. The RF front-end, and especially the mixer, limits the performance of direct conversion ...

  20. Occurrence of the lobe plasma at lunar distance

    International Nuclear Information System (INIS)

    Hardy, D.A.; Hills, H.K.; Freeman, J.W.

    1979-01-01

    Recent analysis has confirmed and expanded the characterization of the lobe plasma, the extension of the 'boundary layer' and 'plasma mantle' to lunar distances. Careful statistical analysis has verified that Magnetic Field (1MF). When the moon is in the dawnside of the northern lobe or duskside of the southern lobe, the probability for observation of the lobe plasma is greatly increased when, in the hour preceding, the IMF has had a positive y component. Conversely, when the moon is in the duskside of the northern lobe or dawnside of the southern lobe, the probability for observation is much increased when the IMF has a negative y component. Analysis of lobe plasma data in conjunction with high time resolution IMF data has shown the probability of observation also is greater with a southward pointing IMF. The observed correlations with the y and z components the IMF reflect the fact that the asymmetry and changes in magnitude of the polar cap electric field induced by the IMF extends to lunar distances and determines the depth into the tail to which the ions can drift. Generally, the lobe plasma is observed sporadically for a full day after the moon has entered the tail and a full day before the last magnetopause crossing as it exits the tail. An average extent of approx.8--10R/sub e/ inward from the magnetopause is inferred; however, the lobe plasma has been seen all across the tail

  1. Terahertz Heterodyne Receiver with an Electron-Heating Mixer and a Heterodyne Based on the Quantum-Cascade Laser

    Science.gov (United States)

    Seliverstov, S. V.; Anfertyev, V. A.; Tretyakov, I. V.; Ozheredov, I. A.; Solyankin, P. M.; Revin, L. S.; Vaks, V. L.; Rusova, A. A.; Goltsman, G. N.; Shkurinov, A. P.

    2017-12-01

    We study characteristics of the laboratory prototype of a terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. The results obtained demonstrate the possibility to use this receiver as a basis for creation of a high-sensitivity terahertz spectrometer, which can be used in many basic and practical applications. A significant advantage of this receiver will be the possibility of placing the mixer and heterodyne in the same cryostat, which will reduce the device dimensions considerably. The obtained experimental results are analyzed, and methods of optimizing the parameters of the receiver are proposed.

  2. MRI findings of temporal lobe ganglioglioma

    International Nuclear Information System (INIS)

    Lee, Myung Jun; Lee, Ho Kyu; Lee, Jung Kyo; Choi, Choong Gon; Suh, Dae Chul

    1999-01-01

    Ganglioglioma is a rare primary brain tumor usually found in the temporal lobe. The purpose of this study is to describe the characteristic MR findings of temporal lobe ganglioglioma. Over a seven-year period, ten patients with cerebral ganglioglioma were evaluated at our institution. Seven cases of temporal lobe ganglioma were found ; six of these involved men, and one, a woman ; their mean age was 29.6 years. In three patients, Gd-DTPA-enhanced T1-weighted images were also obtained. We retrospectively analysed the MRI findings with respect to location, size, cortical involvement, margin, cystic change, degree of enhancement, MR signal intensity, calcification and peritumoral change. In five cases, tumors were located within the temporal lobe. In one, a tumor extended from the temporal lobe to the thalamus, and in one from the temporal lobe to the thalamus and cerebral peduncle. All temporal gangliogliomas measured 1.6-3.8cm in their greatest diameter (mean diameter, 2.7cm). In all cases, the cortices were involved with the maintenance of gyriform. The tumor margin was ill defined in five cases and well defined in two. Tumors showed multiple small cystic changes in four cases, a large cyst in two, and a solid nodule in one. In three cases in which contrast media was administered, no lesions were enhanced. On T1-weighted images, iso-signal intensities were seen in five cases and high signal intensities in two. On T2-weighted images, the corresponding figures were five and two. On MRI, tumor calcification and calvarial erosion were each detected in two cases. In patients with temporal lobe epilepsy in whom cortical solid or cystic and poorly enhanced lesions were seen on brain MRI, and in whom associated findings such as calcification and or adjacent bony erosion were noted, ganglioglioma must be considered

  3. Mixer pump long term operations plan for Tank 241-SY-101 mitigation

    International Nuclear Information System (INIS)

    Irwin, J.J.

    1994-01-01

    This document provides the general Operations Plan for performance of the mixer pump long term operations for Tank 241-SY-101 mitigation of gas retention and periodic release in Tank 101-SY. This operations plan will utilize a 112 kW (150 hp) mixing pump to agitate/suspend the particulates in the tank

  4. design and fabrication of a fou fabrication of a foundry sand mixer

    African Journals Online (AJOL)

    eobe

    favourably with the the imported existing one which urably with the the imported existing one which foundry shops will eliminate the use manual effort save the the country of huge save the the country of huge foreign exchange used i foreign exchange used i. Keywords: Keywords:foundry,sand mixer,fabrication,design,bla.

  5. Granular flow in static mixers by coupled DEM/CFD approach

    OpenAIRE

    Pezo Lato; Pezo Milada; Jovanović Aca; Kosanić Nenad; Petrović Aleksandar; Lević Ljubinko

    2016-01-01

    The mixing process greatly influence the mixing efficiency, as well as the quality and the price of the intermediate and/or the final product. Static mixer is used for premixing action before the main mixing process, for significant reduction of mixing time and energy consumption. This type of premixing action is not investigated in detail in the open literature. In this article, the novel numerical approach called Discrete Element Method is used for modell...

  6. Intralobar fibres of the occipital lobe: a post mortem dissection study.

    Science.gov (United States)

    Vergani, Francesco; Mahmood, Sajedha; Morris, Cristopher M; Mitchell, Patrick; Forkel, Stephanie J

    2014-07-01

    The atlas by Heinrich Sachs (1892) provided an accurate description of the intralobar fibres of the occipital lobe, with a detailed representation of the short associative tracts connecting different parts of the lobe. Little attention has been paid to the work of Sachs since its publication. In this study, we present the results of the dissection of three hemispheres, performed according to the Klingler technique (1935). Our anatomical findings are then compared to the original description of the occipital fibres anatomy as detailed by Sachs. Three hemispheres were dissected according to Klingler's technique (1935). Specimens were fixed in 10% formalin and frozen at -15 °C for two weeks. After defreezing, dissection of the white matter fibres was performed with blunt dissectors. Coronal sections were obtained according to the cuts originally described by Sachs. In addition, medial to lateral and lateral to medial dissection of the white matter of the occipital lobe was also performed. A network of short association fibres was demonstrated in the occipital lobe, comprising intralobar association fibres and U-shaped fibres, which are connecting neighbouring gyri. Lateral to the ventricles, longitudinal fibres of the stratum sagittale were also identified that are arranged as external and internal layers. Fibres of the forceps major were also found to be in direct contact with the ventricular walls. We were able to replicate all tracts originally described by Sachs. In addition, a previously unrecognised tract, connecting the cuneus to the lingual gyrus, was identified. This tract corresponds to the "sledge runner", described in tractography studies. The occipital lobe shows a rich network of intralobar fibres, arranged around the ventricular wall. Good concordance was observed between the Klingler dissection technique and the histological preparations of Sachs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. A discussion on the safety classification of the tank 241-SY-101 mixer pump

    International Nuclear Information System (INIS)

    Van Vleet, R.J.

    1997-01-01

    An analysis, consistent with the methodology used in the draft TWRS FSAR (HNF-SD-WM-SAR-067), is presented to show that the classification of the mixer pump in tank 241-SY-101 should be safety significant

  8. Features of internal water supply and water disposal of shopping centers

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2014-01-01

    Full Text Available Pipeline from an external system should be inlet in the part of the building where a large number of water folding devices will be concentrated. As a rule, for shopping centers with a lot of water consumers it is necessary to make not less than three inputs, each of them should be connected to different areas of an external ring water supply system in order to make the work of the system more reliable.The places for water folding fittings in shopping centers are the following. The water folding devices: mixers are placed in sanitary cabins of shopping centers. Usually, for for water saving in buildings with a big pass-through capacity per hour it is reasonable to use contactless mixers, which are turned on upon raising a hand with a help of motion sensor or light sensor. Another important argument in favor of such mixers is prevention of infections spread for the reason that the consumer doesn't touch the device, so, the risk of bacteria transmission via the device decreases. Such mixer supplies water with a demanded expense and temperature. As a rule, water for such mixers moves from the centralized internal water supply system of hot water, mixing up with cold water. If there is no centralized hot water supply system, it is possible to use hot water storage heaters in case of a small number of visitors or to reject mixers at all in favor of the cranes giving water of only one temperature (cold, which is also practiced.For the branch of economic and household the water receivers are used, which are present in sanitary cabins in most cases by toilet bowls, wash basins, urinals.

  9. Wide-band operation of quasi-optical distributed superconductor/insulator/superconductor mixers with epitaxial NbN/AlN/NbN junctions

    International Nuclear Information System (INIS)

    Kohjiro, S; Shitov, S V; Wang, Z; Uzawa, Y; Miki, S; Kawakami, A; Shoji, A

    2004-01-01

    For the optimum design of integrated receivers operating above the gap frequency of Nb, we have designed, fabricated and tested NbN-based quasi-optical superconductor/insulator/superconductor (SIS) mixers. The mixer chip incorporates a resonant half-wavelength epitaxial NbN/AlN/NbN junction, a twin-slot antenna and their coupling circuits. We adopted two kinds of coupling circuit between the antenna and the SIS junction: one is an in-phase feed with a length of 95 μm and the other is an anti-phase feed of 30 μm length. It was found that the anti-phase mixer reveals a 3 dB bandwidth of 43% of the centre frequency; the uncorrected double-sideband receiver noise temperature T RX = 691 K at 0.91 THz and T RX = 844 K at 0.80 THz, while 17% and T RX = 1250 K at 0.79 THz for the in-phase version. Possible reasons for this difference are discussed, which could be transmission loss and its robustness with respect to the variation of junction parameters. These experimental results suggest the NbN-based distributed mixer with the anti-phase feed is a better candidate for wide-band integrated receivers operating above 0.7 THz

  10. Optimization of a continuous hybrid impeller mixer via computational fluid dynamics.

    Science.gov (United States)

    Othman, N; Kamarudin, S K; Takriff, M S; Rosli, M I; Engku Chik, E M F; Meor Adnan, M A K

    2014-01-01

    This paper presents the preliminary steps required for conducting experiments to obtain the optimal operating conditions of a hybrid impeller mixer and to determine the residence time distribution (RTD) using computational fluid dynamics (CFD). In this paper, impeller speed and clearance parameters are examined. The hybrid impeller mixer consists of a single Rushton turbine mounted above a single pitched blade turbine (PBT). Four impeller speeds, 50, 100, 150, and 200 rpm, and four impeller clearances, 25, 50, 75, and 100 mm, were the operation variables used in this study. CFD was utilized to initially screen the parameter ranges to reduce the number of actual experiments needed. Afterward, the residence time distribution (RTD) was determined using the respective parameters. Finally, the Fluent-predicted RTD and the experimentally measured RTD were compared. The CFD investigations revealed that an impeller speed of 50 rpm and an impeller clearance of 25 mm were not viable for experimental investigations and were thus eliminated from further analyses. The determination of RTD using a k-ε turbulence model was performed using CFD techniques. The multiple reference frame (MRF) was implemented and a steady state was initially achieved followed by a transient condition for RTD determination.

  11. Multi frequency excited MEMS cantilever beam resonator for Mixer-Filter applications

    KAUST Repository

    Chandran, Akhil A.

    2016-09-15

    Wireless communication uses Radio Frequency waves to transfer information from one point to another. The modern RF front end devices are implementing MEMS in their designs so as to exploit the inherent properties of MEMS devices, such as its low mass, low power consumption, and small size. Among the components in the RF transceivers, band pass filters and mixers play a vital role in achieving the optimum RF performance. And this paper aims at utilizing an electrostatically actuated micro cantilever beam resonator\\'s nonlinear frequency mixing property to realize a Mixer-Filter configuration through multi-frequency excitation. The paper studies about the statics and dynamics of the device. Simulations are carried out to study the added benefits of multi frequency excitation. The modelling of the cantilever beam has been done using a Reduced Order Model of the Euler-Bernoulli\\'s beam equation by implementing the Galerkin discretization. The device is shown to be able to down-convert signals from 960 MHz of frequency to an intermediate frequency around 50 MHz and 70 MHz in Phase 1 and 2, respectively. The simulation showed promising results to take the project to the next level. © 2016 IEEE.

  12. Multi frequency excited MEMS cantilever beam resonator for Mixer-Filter applications

    KAUST Repository

    Chandran, Akhil A.; Younis, Mohammad I.

    2016-01-01

    Wireless communication uses Radio Frequency waves to transfer information from one point to another. The modern RF front end devices are implementing MEMS in their designs so as to exploit the inherent properties of MEMS devices, such as its low mass, low power consumption, and small size. Among the components in the RF transceivers, band pass filters and mixers play a vital role in achieving the optimum RF performance. And this paper aims at utilizing an electrostatically actuated micro cantilever beam resonator's nonlinear frequency mixing property to realize a Mixer-Filter configuration through multi-frequency excitation. The paper studies about the statics and dynamics of the device. Simulations are carried out to study the added benefits of multi frequency excitation. The modelling of the cantilever beam has been done using a Reduced Order Model of the Euler-Bernoulli's beam equation by implementing the Galerkin discretization. The device is shown to be able to down-convert signals from 960 MHz of frequency to an intermediate frequency around 50 MHz and 70 MHz in Phase 1 and 2, respectively. The simulation showed promising results to take the project to the next level. © 2016 IEEE.

  13. Evaluation of Flygt Mixers for Application in Savannah River Site Tank 19. Test Results from Phase B: Mid-Scale Testing at PNNL

    International Nuclear Information System (INIS)

    Powell, M.R.; Combs, W.H.; Farmer, J.R.; Gladki, H.; Hatchell, B.K.; Johnson, M.A.; Poirier, M.R.; Rodwell, P.O.

    1999-01-01

    Pacific Northwest National Laboratory (PNNL) performed mixer tests using 3-kW (4-hp) Flygt mixers in 1.8- and 5.7-m-diameter tanks at the 336 building facility in Richland, Washington to evaluate candidate scaling relationships for Flygt mixers used for sludge mobilization and particle suspension. These tests constituted the second phase of a three-phase test program involving representatives from ITT Flygt Corporation, the Savannah River Site (SRS), the Oak Ridge National Laboratory (ORNL), and PNNL. The results of the first phase of tests, which were conducted at ITT Flygt's facility in a 0.45-m-diameter tank, are documented in Powell et al. (1999). Although some of the Phase B tests were geometrically similar to selected Phase A tests (0.45-m tank), none of the Phase B tests were geometrically, cinematically, and/or dynamically similar to the planned Tank 19 mixing system. Therefore, the mixing observed during the Phase B tests is not directly indicative of the mixing expected in Tank 19 and some extrapolation of the data is required to make predictions for Tank 19 mixing. Of particular concern is the size of the mixer propellers used for the 5.7-m tank tests. These propellers were more than three times larger than required by geometric scaling of the Tank 19 mixers. The implications of the lack of geometric similarity, as well as other factors that complicate interpretation of the test results, are discussed in Section 5.4

  14. Study of Crud Formation Using One Stage Mixer Settler for U-Th Extraction

    International Nuclear Information System (INIS)

    Busron-Masduki; Mashudi; Didiek-Herhady, R; Endang-Susiantini

    2000-01-01

    It was carried out solvent extraction of used fuel simulation solution ofU-Th using one stage of mixer settler. The ratio of U/Th was 1/9. Thesolution of U- Th and extractant of 30% TBP diluted in the diluent ofn-dodecane filled in the mixer chamber with the ratio of 1/1 then stirred.The first experiment determined equilibrium time and optimum rpm and thensearched the influenced parameter of crud formation of thorium, zirconium(fission product), phosphate acid, butanol, bentonite powder (represent offines solid), ferrum, silicium according to the TBP degradation of DBP.Zirconium and thorium are significant parameter of crud formation. Theequilibrium time was 1.5 hour, optimum rpm was 1800. The weightest crud wasobtained related to the cumulative parameter which result of 250 gram crud.According to this result and for radiation dose of 1 watt, the extractantmust be regenerated before exceed 48 days to hold the crud formation whichdisturbance the extraction process. (author)

  15. Low noise 874 GHz receivers for the International Submillimetre Airborne Radiometer (ISMAR)

    Science.gov (United States)

    Hammar, A.; Sobis, P.; Drakinskiy, V.; Emrich, A.; Wadefalk, N.; Schleeh, J.; Stake, J.

    2018-05-01

    We report on the development of two 874 GHz receiver channels with orthogonal polarizations for the International Submillimetre Airborne Radiometer. A spline horn antenna and dielectric lens, a Schottky diode mixer circuit, and an intermediate frequency (IF) low noise amplifier circuit were integrated in the same metallic split block housing. This resulted in a receiver mean double sideband (DSB) noise temperature of 3300 K (minimum 2770 K, maximum 3400 K), achieved at an operation temperature of 40 °C and across a 10 GHz wide IF band. A minimum DSB noise temperature of 2260 K at 20 °C was measured without the lens. Three different dielectric lens materials were tested and compared with respect to the radiation pattern and noise temperature. All three lenses were compliant in terms of radiation pattern, but one of the materials led to a reduction in noise temperature of approximately 200 K compared to the others. The loss in this lens was estimated to be 0.42 dB. The local oscillator chains have a power consumption of 24 W and consist of custom-designed Schottky diode quadruplers (5% power efficiency in operation, 8%-9% peak), commercial heterostructure barrier varactor (HBV) triplers, and power amplifiers that are pumped by using a common dielectric resonator oscillator at 36.43 GHz. Measurements of the radiation pattern showed a symmetric main beam lobe with full width half maximum <5° and side lobe levels below -20 dB. Return loss of a prototype of the spline horn and lens was measured using a network analyzer and frequency extenders to 750-1100 GHz. Time-domain analysis of the reflection coefficients shows that the reflections are below -25 dB and are dominated by the external waveguide interface.

  16. Preoperative automated fibre quantification predicts postoperative seizure outcome in temporal lobe epilepsy.

    Science.gov (United States)

    Keller, Simon S; Glenn, G Russell; Weber, Bernd; Kreilkamp, Barbara A K; Jensen, Jens H; Helpern, Joseph A; Wagner, Jan; Barker, Gareth J; Richardson, Mark P; Bonilha, Leonardo

    2017-01-01

    Approximately one in every two patients with pharmacoresistant temporal lobe epilepsy will not be rendered completely seizure-free after temporal lobe surgery. The reasons for this are unknown and are likely to be multifactorial. Quantitative volumetric magnetic resonance imaging techniques have provided limited insight into the causes of persistent postoperative seizures in patients with temporal lobe epilepsy. The relationship between postoperative outcome and preoperative pathology of white matter tracts, which constitute crucial components of epileptogenic networks, is unknown. We investigated regional tissue characteristics of preoperative temporal lobe white matter tracts known to be important in the generation and propagation of temporal lobe seizures in temporal lobe epilepsy, using diffusion tensor imaging and automated fibre quantification. We studied 43 patients with mesial temporal lobe epilepsy associated with hippocampal sclerosis and 44 healthy controls. Patients underwent preoperative imaging, amygdalohippocampectomy and postoperative assessment using the International League Against Epilepsy seizure outcome scale. From preoperative imaging, the fimbria-fornix, parahippocampal white matter bundle and uncinate fasciculus were reconstructed, and scalar diffusion metrics were calculated along the length of each tract. Altogether, 51.2% of patients were rendered completely seizure-free and 48.8% continued to experience postoperative seizure symptoms. Relative to controls, both patient groups exhibited strong and significant diffusion abnormalities along the length of the uncinate bilaterally, the ipsilateral parahippocampal white matter bundle, and the ipsilateral fimbria-fornix in regions located within the medial temporal lobe. However, only patients with persistent postoperative seizures showed evidence of significant pathology of tract sections located in the ipsilateral dorsal fornix and in the contralateral parahippocampal white matter bundle

  17. An unusual case of cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy with occipital lobe involvement.

    Science.gov (United States)

    Trikamji, Bhavesh; Thomas, Mariam; Hathout, Gasser; Mishra, Shrikant

    2016-01-01

    Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is an autosomal dominant angiopathy caused by a mutation in the notch 3 gene on chromosome 19. Clinically, patients may be asymptomatic or can present with recurrent ischemic episodes and strokes leading to dementia, depression, pseudobulbar palsy, and hemi- or quadraplegia. Additional manifestations that have been described include migraine (mostly with aura), psychiatric disturbances, and epileptic seizures. Neuroimaging is essential to the diagnosis of CADASIL. On imaging CADASIL is characterized by symmetric involvement by confluent lesions located subcortically in the frontal and temporal lobes as well as in the insula, periventricularly, in the centrum semiovale, in the internal and external capsule, basal ganglia, and brain stem; with relative sparing of the fronto-orbital and the occipital subcortical regions. We describe a 49 year old male with CADASIL with absence of temporal lobe findings on MRI but predominant lesions within the periventricular white matter, occipital lobes with extension into the subcortical frontal lobes, corpus callosum and cerebellar white matter. Although CADASIL characteristically presents with anterior temporal lobe involvement, these findings may be absent and our case addresses the atypical imaging findings in CADASIL.

  18. An unusual case of cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy with occipital lobe involvement

    Directory of Open Access Journals (Sweden)

    Bhavesh Trikamji

    2016-01-01

    Full Text Available Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL is an autosomal dominant angiopathy caused by a mutation in the notch 3 gene on chromosome 19. Clinically, patients may be asymptomatic or can present with recurrent ischemic episodes and strokes leading to dementia, depression, pseudobulbar palsy, and hemi- or quadraplegia. Additional manifestations that have been described include migraine (mostly with aura, psychiatric disturbances, and epileptic seizures. Neuroimaging is essential to the diagnosis of CADASIL. On imaging CADASIL is characterized by symmetric involvement by confluent lesions located subcortically in the frontal and temporal lobes as well as in the insula, periventricularly, in the centrum semiovale, in the internal and external capsule, basal ganglia, and brain stem; with relative sparing of the fronto-orbital and the occipital subcortical regions. We describe a 49 year old male with CADASIL with absence of temporal lobe findings on MRI but predominant lesions within the periventricular white matter, occipital lobes with extension into the subcortical frontal lobes, corpus callosum and cerebellar white matter. Although CADASIL characteristically presents with anterior temporal lobe involvement, these findings may be absent and our case addresses the atypical imaging findings in CADASIL.

  19. Design of a side-band-separating heterodyne mixer for band 9 of ALMA

    NARCIS (Netherlands)

    Baryshev, AM; Kooi, J; Mena, FR; Lodewijk, CRJ; Wild, W

    2005-01-01

    A side-band-separating (SBS) heterodyne mixer has been designed for the Atacama Large Millimeter Array (ALMA) 602-720 GHz band, as it will present a great improvement over the current double-side-band configuration under development at the moment. Here we present design details and the results of

  20. Surgical Considerations of Intractable Mesial Temporal Lobe Epilepsy

    Science.gov (United States)

    Boling, Warren W.

    2018-01-01

    Surgery of temporal lobe epilepsy is the best opportunity for seizure freedom in medically intractable patients. The surgical approach has evolved to recognize the paramount importance of the mesial temporal structures in the majority of patients with temporal lobe epilepsy who have a seizure origin in the mesial temporal structures. For those individuals with medically intractable mesial temporal lobe epilepsy, a selective amygdalohippocampectomy surgery can be done that provides an excellent opportunity for seizure freedom and limits the resection to temporal lobe structures primarily involved in seizure genesis. PMID:29461485

  1. Surgical Considerations of Intractable Mesial Temporal Lobe Epilepsy

    Directory of Open Access Journals (Sweden)

    Warren W. Boling

    2018-02-01

    Full Text Available Surgery of temporal lobe epilepsy is the best opportunity for seizure freedom in medically intractable patients. The surgical approach has evolved to recognize the paramount importance of the mesial temporal structures in the majority of patients with temporal lobe epilepsy who have a seizure origin in the mesial temporal structures. For those individuals with medically intractable mesial temporal lobe epilepsy, a selective amygdalohippocampectomy surgery can be done that provides an excellent opportunity for seizure freedom and limits the resection to temporal lobe structures primarily involved in seizure genesis.

  2. Quantitative characterization of magnetic separators: Comparison of systems with and without integrated microfluidic mixers

    DEFF Research Database (Denmark)

    Lund-Olesen, Torsten; Bruus, Henrik; Hansen, Mikkel Fougt

    2006-01-01

    micrographs, and simulations and analytical models of bead trajectories, capture efficiencies, and capture distributions. We show that the efficiencies of both systems compare favorably to those in the literature. For the studied geometries, the mixer is demonstrated to increase the bead capture...

  3. The occipital lobe convexity sulci and gyri.

    Science.gov (United States)

    Alves, Raphael V; Ribas, Guilherme C; Párraga, Richard G; de Oliveira, Evandro

    2012-05-01

    The anatomy of the occipital lobe convexity is so intricate and variable that its precise description is not found in the classic anatomy textbooks, and the occipital sulci and gyri are described with different nomenclatures according to different authors. The aim of this study was to investigate and describe the anatomy of the occipital lobe convexity and clarify its nomenclature. The configurations of sulci and gyri on the lateral surface of the occipital lobe of 20 cerebral hemispheres were examined in order to identify the most characteristic and consistent patterns. The most characteristic and consistent occipital sulci identified in this study were the intraoccipital, transverse occipital, and lateral occipital sulci. The morphology of the transverse occipital sulcus and the intraoccipital sulcus connection was identified as the most important aspect to define the gyral pattern of the occipital lobe convexity. Knowledge of the main features of the occipital sulci and gyri permits the recognition of a basic configuration of the occipital lobe and the identification of its sulcal and gyral variations.

  4. A “twisted” microfluidic mixer suitable for a wide range of flow rate applications

    KAUST Repository

    Sivashankar, Shilpa; Agambayev, Sumeyra; Mashraei, Yousof; Li, Erqiang; Thoroddsen, Sigurdur T; Salama, Khaled N.

    2016-01-01

    in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted

  5. Pressure balance between lobe and plasma sheet

    International Nuclear Information System (INIS)

    Baumjohann, W.; Paschmann, G.; Luehr, H.

    1990-01-01

    Using eight months of AMPTE/IRM plasma and magnetic field data, the authors have done a statistical survey on the balance of total (thermal and magnetic) pressure in the Earth's plasma sheet and tail lobe. About 300,000 measurements obtained in the plasma sheet and the lobe were compared for different levels of magnetic activity as well as different distances from the Earth. The data show that lobe and plasma sheet pressure balance very well. Even in the worst case they do not deviate by more than half of the variance in the data itself. Approximately constant total pressure was also seen during a quiet time pass when IRM traversed nearly the whole magnetotail in the vertical direction, from the southern hemisphere lobe through the neutral sheet and into the northern plasma sheet boundary layer

  6. Optimization of a Continuous Hybrid Impeller Mixer via Computational Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    N. Othman

    2014-01-01

    Full Text Available This paper presents the preliminary steps required for conducting experiments to obtain the optimal operating conditions of a hybrid impeller mixer and to determine the residence time distribution (RTD using computational fluid dynamics (CFD. In this paper, impeller speed and clearance parameters are examined. The hybrid impeller mixer consists of a single Rushton turbine mounted above a single pitched blade turbine (PBT. Four impeller speeds, 50, 100, 150, and 200 rpm, and four impeller clearances, 25, 50, 75, and 100 mm, were the operation variables used in this study. CFD was utilized to initially screen the parameter ranges to reduce the number of actual experiments needed. Afterward, the residence time distribution (RTD was determined using the respective parameters. Finally, the Fluent-predicted RTD and the experimentally measured RTD were compared. The CFD investigations revealed that an impeller speed of 50 rpm and an impeller clearance of 25 mm were not viable for experimental investigations and were thus eliminated from further analyses. The determination of RTD using a k-ε turbulence model was performed using CFD techniques. The multiple reference frame (MRF was implemented and a steady state was initially achieved followed by a transient condition for RTD determination.

  7. Origin of frontal lobe spikes in the early onset benign occipital lobe epilepsy (Panayiotopoulos syndrome).

    Science.gov (United States)

    Leal, Alberto J R; Ferreira, José C; Dias, Ana I; Calado, Eulália

    2008-09-01

    Early onset benign occipital lobe epilepsy (Panayiotopoulos syndrome [PS]) is a common and easily recognizable epilepsy. Interictal EEG spike activity is often multifocal but most frequently localized in the occipital lobes. The origin and clinical significance of the extra-occipital spikes remain poorly understood. Three patients with the PS and interictal EEG spikes with frontal lobe topography were studied using high-resolution EEG. Independent component analysis (ICA) was used to decompose the spikes in components with distinct temporal dynamics. The components were mapped in the scalp with a spline-laplacian algorithm. The change in scalp potential topography from spike onset to peak, suggests the contribution of several intracranial generators, with different kinetics of activation and significant overlap. ICA was able to separate the major contributors to frontal spikes and consistently revealed an early activating group of components over the occipital areas in all the patients. The local origin of these early potentials was established by the spline-laplacian montage. Frontal spikes in PS are consistently associated with early and unilateral occipital lobe activation, suggesting a postero-anterior spike propagation. Frontal spikes in the PS represent a secondary activation triggered by occipital interictal discharges and do not represent an independent focus.

  8. Magnetic resonance imaging in temporal lobe epilepsy. Usefulness for the etiological diagnosis of temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Mohamed, A.; Lueders, H.O.

    2000-01-01

    With improvement in magnetic resonance (MR) imaging techniques, the ability to identify lesions responsible for temporal lobe epilepsy has increased. MR imaging has also enabled the in vivo diagnosis of hippocampal sclerosis. Brain tumors are responsible for 2-4% of epilepsies in adult population and 10-20% of medically intractable epilepsy. The sensitivity of MR imaging in the diagnosis of tumors and other lesions of the temporal lobe (vascular malformations, etc.) is around 90%. Both hippocampal sclerosis and other temporal lobe lesions are amenable to surgical therapy with excellent postsurgical seizure outcome. In this article, we characterize and underline distinguishing features of the different pathological entities. We also suggest an approach to reviewing the MR images of an epileptic patient. (author)

  9. Are the dimensions of submarine lobe systems independent of allogenic factors?

    Science.gov (United States)

    Prélat, A.; Covault, J. A.; Hodgson, D. M.; Fildani, A.; Flint, S. S.

    2010-05-01

    Submarine lobe dimensions from six different systems are compared: 1) the exhumed Permian Fan 3 lobe complex of the Tanqua Karoo, South Africa; 2) the modern Amazon fan channel-mouth lobe complex, offshore Brazil; 3) a portion of the modern distal Zaïre fan, offshore Angola / Congo; 4) a Pleistocene fan of the Kutai Basin, subsurface offshore Indonesia; 5) the modern Golo system, offshore east Corsica, France; and 6) a lobe complex deposited in the shallow subsurface, offshore Nigeria. These six systems have significantly different source-to-sink configurations (shelf dimension and slope topography), sediment supply characteristics (calibre and rate), tectonic settings, (palaeo) latitude, and delivery systems. Despite these differences, the lobe deposits share similar geometric and dimensional characteristics. Lobes are grouped into two distinct populations of geometries that can be related to basin-floor topography. The first population corresponds to areally extensive but thin lobes (average width 14 km × length 35 km × thickness 12 m) that were deposited onto low relief basin floor areas, like the Tanqua Karoo, the Amazon and the Zaïre systems. The second population corresponds to areally smaller but thicker lobes (average width 5 km × length 8 km × thickness 30 m) that were deposited into settings with higher amplitude of relief, like in the Corsican trough, the Kutai basin, and offshore Nigeria. Basin floor topography confining the lobes can be very subtle, and only occur on one side of the system. The two populations of lobe types, however, share similar volumes, in the order of 1 or 2 km3. The largest lobes are observed in the Zaïre fan, where the average lobe volume reaches 3.3 km3 and the smallest lobes are observed in the Corsican trough where the average lobe volume is 0.4 km3. This variation in lobe volume is minor when compared to the variation observed in present-day up-dip drainage systems, which provide sediment to the deep-water depositional

  10. High-Tc superconducting Josephson mixers for terahertz heterodyne detection

    International Nuclear Information System (INIS)

    Malnou, M.; Feuillet-Palma, C.; Olanier, L.; Lesueur, J.; Bergeal, N.; Ulysse, C.; Faini, G.; Febvre, P.; Sirena, M.

    2014-01-01

    We report on an experimental and theoretical study of the high-frequency mixing properties of ion-irradiated YBa 2 Cu 3 O 7 Josephson junctions embedded in THz antennas. We investigated the influence of the local oscillator power and frequency on the device performances. The experimental data are compared with theoretical predictions of the general three-port model for mixers in which the junction is described by the resistively shunted junction model. A good agreement is obtained for the conversion efficiency in different frequency ranges, spanning above and below the characteristic frequencies f c of the junctions

  11. A comparison of occipital and temporal lobe epilepsies.

    Science.gov (United States)

    Appel, S; Sharan, A D; Tracy, J I; Evans, J; Sperling, M R

    2015-10-01

    Differentiating between occipital lobe epilepsy (OLE) and temporal lobe epilepsy (TLE) is often challenging. This retrospective case-control study compares OLE to TLE and explores markers that suggest the diagnosis of OLE. We queried the Jefferson Epilepsy Center surgery database for patients who underwent a resection that involved the occipital lobe. For each patient with OLE, three sequential case-control patients with TLE were matched. Demographic characteristics, symptoms, electrophysiological findings, imaging findings, and surgical outcome were compared. Nineteen patients with OLE and 57 patients with TLE were included in the study. Visual symptoms were unique to patients with OLE (8/19) and were not reported by patients with TLE (P Occipital interictal spikes (IIS) were found only in one-third of the patients with OLE (6/19) and in no patients with TLE (P lobe were found in five of 19 patients with OLE vs one of 57 patients with TLE (P = 0.003). IIS involved more than one lobe of the brain in most patients with OLE (11/19) but only in nine of 57 the TLE group. (P = 0.0003) Multilobar resection was needed in most patients with OLE (15/19), typically including the temporal lobe, but in only one of the patients with TLE (P Occipital lobe epilepsy is difficult to identify and may masquerade as temporal lobe epilepsy. Visual symptoms and occipital findings in the EEG suggest the diagnosis of OLE, but absence of these features, does not exclude the diagnosis. When posterior temporal EEG findings or multilobar involvement occurs, the diagnosis of OLE should be considered. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A Theoretical-Experimental Comparison of an Improved Ammonia-Water Bubble Absorber by Means of a Helical Static Mixer

    Directory of Open Access Journals (Sweden)

    Jesús Cerezo

    2017-12-01

    Full Text Available The heat transfer in double pipe heat exchangers is very poor. This complicates its application in absorption cooling systems, however, the implementation of simple passive techniques should help to increase the heat and mass transfer mainly in the absorber. This paper carried out a simulation and its experimental comparison of a NH3-H2O bubble absorption process using a double tube heat exchanger with a helical screw static mixer in both central and annular sides. The experimental results showed that the absorption heat load per area is 31.61% higher with the helical screw mixer than the smooth tube. The theoretical and experimental comparison showed that the absorption heat load difference values were 28.0 and 21.9% for smooth tube and the helical mixer, respectively. These difference values were caused by the calculation of the log mean temperature difference in equilibrium conditions to avoid the overlap of solution temperatures. Therefore, the theoretical and experimental results should be improved when the absorption heat is included in the heat transfer equation or avoiding the operation condition when output is lower than input solution temperature.

  13. Gray, White Matter Concentration Changes and Their Correlation with Heterotopic Neurons in Temporal Lobe Epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Joo, Eun Yun; Kim, Sung Tae; Hong, Seung Bong [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    To identify changes in gray and white matter concentrations (GMC, WMC), and their relation to heterotopic neuron numbers in mesial temporal lobe epilepsy (mTLE). The gray matter or white matter concentrations of 16 left and 15 right mTLE patients who achieved an excellent surgical outcome were compared with those of 24 healthy volunteers for the left group and with 23 healthy volunteers for the right group, by optimized voxel-based morphometry using unmodulated and modulated images. A histologic count of heterotopic neurons was obtained in the white matter of the anterior temporal lobe originating from the patients' surgical specimens. In addition, the number of heterotopic neurons were tested to determine if there was a correlation with the GMC or WMC. The GMCs of the left and right mTLE groups were reduced in the ipsilateral hippocampi, bilateral thalami, precentral gyri, and in the cerebellum. The WMCs were reduced in the ipsilateral white matter of the anterior temporal lobe, bilateral parahippocampal gyri, and internal capsules, but increased in the pons and bilateral precentral gyri. The heterotopic neuron counts in the left mTLE group showed a positive correlation (r = 0.819, p < 0.0001) with GMCs and a negative correlation (r = - 0.839, p < 0.0001) with WMCs in the white matter of the anterior temporal lobe. The present study shows the abnormalities of the cortico-thalamo- hippocampal network including a gray matter volume reduction in the anterior frontal lobes and an abnormality of brain tissue concentration in the pontine area. Furthermore, heterotopic neuron numbers were significantly correlated with GMC or WMC in the left white matter of anterior temporal lobe.

  14. Microfluidic active mixers employing ultra-high aspect-ratio rare-earth magnetic nano-composite polymer artificial cilia

    International Nuclear Information System (INIS)

    Rahbar, Mona; Gray, Bonnie L; Shannon, Lesley

    2014-01-01

    We present a new micromixer based on highly magnetic, flexible, high aspect-ratio, artificial cilia that are fabricated as individual micromixer elements or in arrays for improved mixing performance. These new cilia enable high efficiency, fast mixing in a microchamber, and are controlled by small electromagnetic fields. The artificial cilia are fabricated using a new micromolding process for nano-composite polymers. Cilia fibers with aspect-ratios as high as 8:0.13 demonstrate the fabrication technique's capability in creating ultra-high aspect-ratio microstructures. Cilia, which are realized in polydimethylsiloxane doped with rare-earth magnetic powder, are magnetized to produce permanent magnetic structures with bidirectional deflection capabilities, making them highly suitable as mixers controlled by electromagnetic fields. Due to the high magnetization level of the polarized nano-composite polymer, we are able to use miniature electromagnets providing relatively small magnetic fields of 1.1 to 7 mT to actuate the cilia microstructures over a very wide motion range. Mixing performances of a single cilium, as well as different arrays of multiple cilia ranging from 2 to 8 per reaction chamber, are characterized and compared with passive diffusion mixing performance. The mixer cilia are actuated at different amplitudes and frequencies to optimize mixing performance. We demonstrate that more than 85% of the total volume of the reaction chamber is fully mixed after 3.5 min using a single cilium mixer at 7 mT compared with only 20% of the total volume mixed with passive diffusion. The time to achieve over 85% mixing is further reduced to 70 s using an array of eight cilia microstructures. The novel microfabrication technique and use of rare-earth permanently-magnetizable nano-composite polymers in mixer applications has not been reported elsewhere by other researchers. We further demonstrate improved mixing over other cilia micromixers as enabled by the high

  15. Temporal Lobe Seizure

    Science.gov (United States)

    ... functions, including having odd feelings — such as euphoria, deja vu or fear. Temporal lobe seizures are sometimes called ... sudden sense of unprovoked fear or joy A deja vu experience — a feeling that what's happening has happened ...

  16. Complex modeling of technological processes in pneumatic mixers for production of dry construction mixtures

    Science.gov (United States)

    Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.

    2018-03-01

    The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.

  17. Medical image of the week: right middle lobe syndrome

    Directory of Open Access Journals (Sweden)

    Cristan EA

    2016-05-01

    Full Text Available No abstract available. Article truncated at 150 words. A 73 year-old woman, a lifetime non-smoker, presented to the pulmonary clinic with chronic dyspnea on exertion and cough. Physical exam was unremarkable and pulmonary function testing showed normal spirometry. A chest radiograph revealed calcified mediastinal adenopathy and increased density in the right middle lobe region (Figure 1. A computed tomography scan of the chest revealed significant narrowing of the right middle lobe bronchus with partial atelectasis and prominent calcified mediastinal lymphadenopathy (Figure 2. Bronchoscopy showed no endobronchial lesions but there was evidence of extrinsic compression surrounding the right middle lobe orifice. An endobronchial biopsy revealed noncaseating granulomas. Bronchoscopy cultures and cytology were negative and this was presumed to be from a previous infection with histoplasmosis given the patient’s long-term residence in an endemic area. Given chronic narrowing of right middle lobe bronchus with persistent atelectasis of the right middle lobe, the patient was diagnosed with right middle lobe syndrome. ...

  18. Alterations of the occipital lobe in schizophrenia.

    Science.gov (United States)

    Tohid, Hassaan; Faizan, Muhammad; Faizan, Uzma

    2015-07-01

    The relationship of the occipital lobe of the brain with schizophrenia is not commonly studied; however, this topic is considered an essential subject matter among clinicians and scientists. We conducted this systematic review to elaborate the relationship in depth. We found that most schizophrenic patients show normal occipital anatomy and physiology, a minority showed dwindled values, and some demonstrated augmented function and structure. The findings are laborious to incorporate within single disease models that present the involvement of the occipital lobe in schizophrenia. Schizophrenia progresses clinically in the mid-twenties and thirties and its prognosis is inadequate. Changes in the volume, the gray matter, and the white matter in the occipital lobe are quite evident; however, the mechanism behind this involvement is not yet fully understood. Therefore, we recommend further research to explore the occipital lobe functions and volumes across the different stages of schizophrenia.

  19. Alterations of the occipital lobe in schizophrenia

    Science.gov (United States)

    Tohid, Hassaan; Faizan, Muhammad; Faizan, Uzma

    2015-01-01

    The relationship of the occipital lobe of the brain with schizophrenia is not commonly studied; however, this topic is considered an essential subject matter among clinicians and scientists. We conducted this systematic review to elaborate the relationship in depth. We found that most schizophrenic patients show normal occipital anatomy and physiology, a minority showed dwindled values, and some demonstrated augmented function and structure. The findings are laborious to incorporate within single disease models that present the involvement of the occipital lobe in schizophrenia. Schizophrenia progresses clinically in the mid-twenties and thirties and its prognosis is inadequate. Changes in the volume, the gray matter, and the white matter in the occipital lobe are quite evident; however, the mechanism behind this involvement is not yet fully understood. Therefore, we recommend further research to explore the occipital lobe functions and volumes across the different stages of schizophrenia. PMID:26166588

  20. Safety Evaluation for Packaging 101-SY Hydrogen Mitigation Mixer Pump package

    International Nuclear Information System (INIS)

    Carlstrom, R.F.

    1994-01-01

    This Safety Evaluation for Packaging (SEP) provides analysis and considered necessary to approve a one-time transfer of the 101-SY Hydrogen Mitigation Mixer Pump (HMMP). This SEP will demonstrate that the transfer of the HMMP in a new shipping container will provide an equivalent degree of safety as would be provided by packages meeting US Department of Transportation (DOT)/US Nuclear Regulatory Commission (NRC) requirements. This fulfills onsite, transportation requirements implemented by WHC-CM-2-14

  1. Safety Evaluation for Packaging 101-SY Hydrogen Mitigation Mixer Pump package

    Energy Technology Data Exchange (ETDEWEB)

    Carlstrom, R.F.

    1994-10-05

    This Safety Evaluation for Packaging (SEP) provides analysis and considered necessary to approve a one-time transfer of the 101-SY Hydrogen Mitigation Mixer Pump (HMMP). This SEP will demonstrate that the transfer of the HMMP in a new shipping container will provide an equivalent degree of safety as would be provided by packages meeting US Department of Transportation (DOT)/US Nuclear Regulatory Commission (NRC) requirements. This fulfills onsite, transportation requirements implemented by WHC-CM-2-14.

  2. Design and Fabrication of an Industrial Poultry Feed Tumble Mixer

    Directory of Open Access Journals (Sweden)

    Osokam Shadrach ONYEGU

    2012-08-01

    Full Text Available This paper presents the design and fabrication of a poultry feed industrial tumble mixer. The design computations to handle a 50Kg mass of feed was done in the MS Excel environment for proper machine design approach. The machine was designed using AUTOCAD 2D/3D design software and proper material selection was done before the assembling and fabrication of parts. The efficiency of the machine, its associated cost of production and the product obtained after few minutes of mixing were outstanding, thereby, making the design acceptable and cost effective.

  3. Phase separation in an experimental mixer-settler

    International Nuclear Information System (INIS)

    Eckert, N.L.; Gormely, L.S.

    1989-01-01

    An experimental investigation was undertaken to study the factors affecting phase separation in a laboratory scale mixer-settler using a laboratory-prepared commercial oxime-copper system, and a system obtained from the Key Lake uranium extraction circuit. Besides being dependent on specific settler flow, the dispersion band thickness was found to be a function of the phase ratio and dispersion introduction level (uranium system only), and temperature. Drop size was found to be independent of dispersion throughout, a weak function of impeller speed, and a relatively strong function of the phase ratio. Microscopic examination of the uranium dispersion revealed the existence of drops within drops. With the exception of the organic continuous copper system, it was possible to distinguish two horizontal sublayers within the dispersion band. This structure conforms to the model provided by Barnea and Mizrahi. (author)

  4. Wisconsin Card Sorting Test performance and impulsivity in patients with temporal lobe epilepsy: suicidal risk and suicide attempts.

    Science.gov (United States)

    Garcia Espinosa, Arlety; Andrade Machado, René; Borges González, Susana; García González, María Eugenia; Pérez Montoto, Ariadna; Toledo Sotomayor, Guillermo

    2010-01-01

    The goal of the study described here was to determine if executive dysfunction and impulsivity are related to risk for suicide and suicide attempts in patients with temporal lobe epilepsy. Forty-two patients with temporal lobe epilepsy were recruited. A detailed medical history, neurological examination, serial EEGs, Mini-International Neuropsychiatric Interview, executive function, and MRI were assessed. Multiple regression analysis was carried out to examine predictive associations between clinical variables and Wisconsin Card Sorting Test measures. Patients' scores on the Risk for Suicide Scale (n=24) were greater than 7, which means they had the highest relative risk for suicide attempts. Family history of psychiatric disease, current major depressive episode, left temporal lobe epilepsy, and perseverative responses and total errors on the Wisconsin Card Sorting Test increased by 6.3 and 7.5 suicide risk and suicide attempts, respectively. Executive dysfunction (specifically perseverative responses and more total errors) contributed greatly to suicide risk. Executive performance has a major impact on suicide risk and suicide attempts in patients with temporal lobe epilepsy. 2009 Elsevier Inc. All rights reserved.

  5. Bilateral optical nerve atrophy secondary to lateral occipital lobe infarction.

    Science.gov (United States)

    Mao, Junfeng; Wei, Shihui

    2013-06-01

    To report a phenomenon of optical nerve atrophy secondary to lateral occipital lobe infarction. Two successive patients with unilateral occipital lobe infarction who experienced bilateral optical nerve atrophy during the follow-up underwent cranial imaging, fundus photography, and campimetry. Each patient was diagnosed with occipital lobe infarction by cranial MRI. During the follow-up, a bilateral optic atrophy was revealed, and campimetry showed a right homonymous hemianopia of both eyes with concomitant macular division. Bilateral optic atrophy was related to occipital lobe infarction, and a possible explanation for the atrophy was transneuronal degeneration caused by occipital lobe infarction.

  6. A submillimetre-wave SIS mixer using NbN/MgO/NbN trilayers grown epitaxially on an MgO substrate

    CERN Document Server

    Uzawa, Y; Saito, A; Takeda, M; Wang, Z

    2002-01-01

    We have designed, fabricated and tested a quasi-optical superconductor-insulator-superconductor (SIS) mixer employing distributed NbN/MgO/NbN tunnel junctions and NbN/MgO/NbN microstriplines at submillimetre-wave frequencies. These trilayers were fabricated by dc- and rf-magnetron sputtering on an MgO substrate at ambient temperature so that the NbN and MgO films were grown epitaxially. Our SIS mixer consists of an MgO hyperhemispherical lens with an antireflection cap and a self-complementary log-periodic antenna made of a single-crystal NbN film, on which the distributed SIS junctions and the two-section impedance transformers were mirror-symmetrically placed at the feed point of the antenna. As designed, the junctions are 0.6 mu m wide and 15.5 mu m long, which is sufficient to absorb the incoming signal along this lossy transmission line, assuming a current density of 10 kA cm sup - sup 2. The mixer showed good I-V characteristics, with subgap-to-normal resistance ratios of about 13, although weak-link br...

  7. Radiologic evaluation of right middle lobe collapse

    International Nuclear Information System (INIS)

    Kwun, Dae Young; Kim, Jong Deok; Kim, Jong Chul

    1989-01-01

    There are many pathogenetic factors for collapse of right middle lobe; profuse peribronchial clustering of lymph nodes about the right middle lobe bronchus, poor drainage of the bronchus because of its acute angle of take-off from the intermediate bronchus, and the isolation of this small lobe from the right upper and lower lobes, and thus from the aerating effects of collateral ventilation. Retrospectively we reviewed 36 cases of right of right middle lobe collapse of which causes were confirmed by histopathologic or bronchographic findings during the recent 6 years from March 1983 to February 1988 at Inje College Pusan Paik Hospital, and obtained the following results: 1. Male to female ratio was 1:1:4,and peak incidence (64%) was in the fifth and sixth decades with the mean age of 51.1 years. 2. Bronchiectasis was the most common cause (30.6%), and the others were chronic bronchitis (25.0%), pulmonary tuberculosis (19.4%), lung cancer (16.7%), and non-specific inflammatory disease (8.3%). This suggests benign disease is 5 times more common cause of right middle lobe collapse than lung cancer. 3. Among the plain chest radiolograph findings, obliteration of right cardiac border and triangular radiopaque density were the most frequent findings(77.8% in each) and the next was downward and anterior displacement of minor and major fissures (55.6%) 4. Bronchography was done in 11 cases; bronchiectasis was found in 8 cases and chronic bronchitis in 3 cases. Right middle lobe bronchus was obstructed in 2 cases of chronic bronchitis. 5. Chest CT scan was performed in 4 cases of lung cancer, 2 of non-specific inflammatory disease, and 1 of pulmonary tuberculosis: all of lung cancer revealed hilar mass, budged or lobulated fissures, in homogenous density, and mediastinal lymph node enlargement, and all benign disease showed homogenous density and flat to concave fissures. Right middle lobar bronchus narrowing was seen in 5 cases and its obstruction in 2 cases

  8. Simulation Modeling of Non-Homogeneous Mixture in the Horizontal Drum Mixer

    Directory of Open Access Journals (Sweden)

    Andrey Vladimirovich Ostroukh

    2015-05-01

    Full Text Available The paper proposes a simulation model of the diffusion mixing of solids, based on the theory of probability and stochastic diffusion model of imperfect processes of solid particles. It is assumed that the particles have different sizes and density. Model of the program implemented in the AnyLogic SoftWare. Developed a simulation model to evaluate the differences between the intense mixing processes in time and assess their impact on the course of other processes in a horizontal drum mixer.

  9. Reconstruction of conductivity change in lung lobes utilizing electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Schullcke Benjamin

    2017-09-01

    Full Text Available Electrical Impedance Tomography (EIT is a novel medical imaging technology which is expected to give valuable information for the treatment of mechanically ventilated patients as well as for patients with obstructive lung diseases. In lung-EIT electrodes are attached around the thorax to inject small alternating currents and to measure resulting voltages. These voltages depend on the internal conductivity distribution and thus on the amount of air in the lungs. Based on the measured voltages, image reconstruction algorithms are employed to generate tomographic images reflecting the regional ventilation of the lungs. However, the ill-posedness of the reconstruction problem leads to reconstructed images that are severely blurred compared to morphological imaging technologies, such as X-ray computed tomography or Magnetic Resonance Imaging. Thus, a correct identification of the particular ventilation in anatomically assignable units, e.g. lung-lobes, is often hindered. In this study a 3D-FEM model of a human thorax has been used to simulate electrode voltages at different lung conditions. Two electrode planes with 16 electrodes at each layer have been used and different amount of emphysema and mucus plugging was simulated with different severity in the lung lobes. Patient specific morphological information about the lung lobes is used in the image reconstruction process. It is shown that this kind of prior information leads to better reconstructions of the conductivity change in particular lung lobes than in classical image reconstruction approaches, where the anatomy of the patients’ lungs is not considered. Thus, the described approach has the potential to open new and promising applications for EIT. It might be used for diagnosis and disease monitoring for patients with obstructive lung diseases but also in other applications, e.g. during the placement of endobronchial valves in patients with severe emphysema.

  10. The extratemporal lobe epilepsies in the epilepsy monitoring unit

    Science.gov (United States)

    Dash, Deepa; Tripathi, Manjari

    2014-01-01

    Extratemporal lobe epilepsies (ETLE) are characterized by the epileptogenic foci outside the temporal lobe. They have a wide spectrum of semiological presentation depending upon the site of origin. They can arise from frontal, parietal, occipital lobes and from hypothalamic hamartoma. We discuss in this review the semiology of different types of ETLE encountered in the epilepsy monitoring unit. PMID:24791090

  11. A Rare Case of Craniopharyngioma in the Temporal Lobe

    Directory of Open Access Journals (Sweden)

    Sasan Razmjoo

    2017-01-01

    Full Text Available Herein, we report on a rare case of craniopharyngioma arising in the left temporal lobe with no prior history of head trauma or surgery. There was a solid-cystic mass in the left temporal lobe on MR images. To the best of our knowledge, this is the second case of a craniopharyngioma occurring in the temporal lobe.

  12. Foaming/antifoaming in WTP Tanks Equipped with Pulse Jet Mixer and Air Spargers

    International Nuclear Information System (INIS)

    HASSAN, NEGUIB

    2004-01-01

    The River Protection Project-Waste Treatment Plant (RPP-WTP) requested Savannah River National Laboratory (SRNL) to conduct small-scale foaming and antifoam testing using actual Hanford waste and simulants subjected to air sparging. The foaminess of Hanford tank waste solutions was previously demonstrated in SRNL during WTP evaporator foaming and ultrafiltration studies and commercial antifoam DOW Q2-3183A was recommended to mitigate the foam in the evaporators. Currently, WTP is planning to use air spargers in the HLW Lag Storage Vessels, HLW Concentrate Receipt Vessel, and the Ultrafiltration Vessels to assist the performance of the Jet Pulse Mixers (JPM). Sparging of air into WTP tanks will induce a foam layer within the process vessels. The air dispersion in the waste slurries and generated foams could present problems during plant operation. Foam in the tanks could also adversely impact hydrogen removal and mitigation. Antifoam (DOW Q2-3183A) will be used to control foaming in Hanford sparged waste processing tanks. These tanks will be mixed by a combination of pulse-jet mixers and air spargers. The percent allowable foaminess or freeboard in WTP tanks are shown in tables

  13. Formation of Bipolar Lobes by Jets

    Science.gov (United States)

    Soker, Noam

    2002-04-01

    I conduct an analytical study of the interaction of jets, or a collimated fast wind (CFW), with a previously blown asymptotic giant branch (AGB) slow wind. Such jets (or CFWs) are supposedly formed when a compact companion, a main-sequence star, or a white dwarf accretes mass from the AGB star, forms an accretion disk, and blows two jets. This type of flow, which I think shapes bipolar planetary nebulae (PNs), requires three-dimensional gasdynamical simulations, which are limited in the parameter space they can cover. By imposing several simplifying assumptions, I derive simple expressions which reproduce some basic properties of lobes in bipolar PNs and which can be used to guide future numerical simulations. I quantitatively apply the results to two proto-PNs. I show that the jet interaction with the slow wind can form lobes which are narrow close to, and far away from, the central binary system, and which are wider somewhere in between. Jets that are recollimated and have constant cross section can form cylindrical lobes with constant diameter, as observed in several bipolar PNs. Close to their source, jets blown by main-sequence companions are radiative; only further out they become adiabatic, i.e., they form high-temperature, low-density bubbles that inflate the lobes.

  14. Advanced Design Mixer Pump Tank 18 Design Modifications Summary Report

    International Nuclear Information System (INIS)

    Adkins, B.J.

    2002-01-01

    The Westinghouse Savannah River Company (WSRC) is preparing to retrieve high level waste (HLW) from Tank 18 in early FY03 to provide feed for the Defense Waste Processing Facility (DWPF) and to support tank closure in FY04. As part of the Tank 18 project, WSRC will install a single Advanced Design Mixer Pump (ADMP) in the center riser of Tank 18 to mobilize, suspend, and mix radioactive sludge in preparation for transfer to Tank 7. The use of a single ADMP is a change to the current baseline of four (4) standard slurry pumps used during previous waste retrieval campaigns. The ADMP was originally conceived by Hanford and supported by SRS to provide a more reliable and maintainable mixer pump for use throughout the DOE complex. The ADMP underwent an extensive test program at SRS between 1998 and 2002 to assess reliability and hydraulic performance. The ADMP ran for approximately 4,200 hours over the four-year period. A detailed tear down and inspection of the pump following the 4,2 00-hour run revealed that the gas mechanical seals and anti-friction bearings would need to be refurbished/replaced prior to deployment in Tank 18. Design modifications were also needed to meet current Authorization Basis safety requirements. This report documents the modifications made to the ADMP in support of Tank 18 deployment. This report meets the requirements of Tanks Focus Area (TFA) Milestone 3591.4-1, ''Issue Report on Modifications Made to the ADMP,'' contained in Technical Task Plan (TTP) SR16WT51, ''WSRC Retrieval and Closure.''

  15. Channel systems and lobe construction in the Mississippi Fan

    Science.gov (United States)

    Garrison, L. E.; Kenyon, Neil H.; Bouma, A.H.

    1982-01-01

    Morphological features on the Mississippi Fan in the eastern Gulf of Mexico were mapped using GLORIA II, a long-range side-scan sonar system. Prominent is a sinuous channel flanked by well-developed levees and occasional crevasse splays. The channel follows the axis and thickest part of the youngest fan lobe; seismic-reflection profiles offer evidence that its course has remained essentially constant throughout lobe development. Local modification and possible erosion of levees by currents indicates a present state of inactivity. Superficial sliding has affected part of the fan lobe, but does not appear to have been a factor in lobe construction. ?? 1982 A. M. Dowden, Inc.

  16. Decreased occipital lobe metabolism by FDG-PET/CT

    Science.gov (United States)

    Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun

    2017-01-01

    Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205

  17. The presence and growth of Legionella species in thermostatic shower mixer taps: an exploratory field study

    NARCIS (Netherlands)

    Joost van Hoof; P.W.J.J. van der Wielen; E. van der Blom; O.W.W. Nuijten; L. Hornstra

    2014-01-01

    Legislation in the Netherlands requires routine analysis of drinking water samples for cultivable Legionella species from high-priority installations. A field study was conducted to investigate the presence of Legionella species in thermostatic shower mixer taps. Water samples and the interior of

  18. [Two cases of mesial temporal lobe epilepsy associated with old intracerebral hemorrhage in the lateral temporal lobe without "dual pathology"].

    Science.gov (United States)

    Morioka, T; Nishio, S; Hisada, K; Muraishi, M; Ishibashi, H; Mamiya, K; Ohfu, M; Fukui, M

    1998-05-01

    Two cases of intractable temporal lobe epilepsy associated with old intracerebral hemorrhage in the lateral temporal lobe were reported. Although preoperative magnetic resonance imaging (MRI) failed to reveal hippocampal atrophy with T2 hyperintensity, electrocorticographic (ECoG) recording with chronic invasive subdural electrodes indicated the mesial temporal lobe to be an ictal onset zone. After anterior temporal lobectomy involving the lesion and hippocampectomy, the patients became seizure-free. Hippocampal sclerosis, namely "dual pathology", was not noted on histological examination. Careful ECoG recording with chronic subdural electrodes is mandatory even when the preoperative MRI does not demonstrate the radiological hippocampal sclerosis.

  19. Supplementary CT temporal lobe cuts confer no worthwhile benefit

    International Nuclear Information System (INIS)

    Straiton, J.A.; Macpherson, P.; Teasdale, E.M.

    1991-01-01

    The value of angled temporal lobe cuts as a supplement to conventional head computed tomography (CT) has been assessed by comparing the diagnostic yield of standard axial and specific temporal lobe images (TLCT) in 62 patients with temporal lobe epilepsy and 87 with Alzheimer-type senile dementia. Fewer than one patient in six had structural abnormality in the temporal lobe most readily demonstrated by axial CT. Five patients with epilepsy and ten with dementia had changes demonstrated only by TLCT, reported on by one or other of a pair of observers. However such changes were of dubious clinical relevance, or arose as a result of artefact. In one patient with epilepsy and underlying neoplasm, axial CT was positive and TLCT false-negative. The routine addition of temporal lobe cuts to a conventional axial examination confers no added benefit to justify the prolonged examination time and increased radiation dose to the lens of the eye. (orig.)

  20. Supplementary CT temporal lobe cuts confer no worthwhile benefit

    Energy Technology Data Exchange (ETDEWEB)

    Straiton, J A; Macpherson, P; Teasdale, E M [Institute of Neurological Sciences, Glasgow (UK). Dept. of Neuroradiology

    1991-02-01

    The value of angled temporal lobe cuts as a supplement to conventional head computed tomography (CT) has been assessed by comparing the diagnostic yield of standard axial and specific temporal lobe images (TLCT) in 62 patients with temporal lobe epilepsy and 87 with Alzheimer-type senile dementia. Fewer than one patient in six had structural abnormality in the temporal lobe most readily demonstrated by axial CT. Five patients with epilepsy and ten with dementia had changes demonstrated only by TLCT, reported on by one or other of a pair of observers. However such changes were of dubious clinical relevance, or arose as a result of artefact. In one patient with epilepsy and underlying neoplasm, axial CT was positive and TLCT false-negative. The routine addition of temporal lobe cuts to a conventional axial examination confers no added benefit to justify the prolonged examination time and increased radiation dose to the lens of the eye. (orig.).

  1. White matter microstructural abnormalities in the frontal lobe of adults with antisocial personality disorder.

    Science.gov (United States)

    Sundram, Frederick; Deeley, Quinton; Sarkar, Sagari; Daly, Eileen; Latham, Richard; Craig, Michael; Raczek, Malgorzata; Fahy, Tom; Picchioni, Marco; Barker, Gareth J; Murphy, Declan G M

    2012-02-01

    Antisocial personality disorder (ASPD) and psychopathy involve significant interpersonal and behavioural impairments. However, little is known about their underlying neurobiology and in particular, abnormalities in white matter (WM) microstructure. A preliminary diffusion tensor magnetic resonance imaging (DT-MRI) study of adult psychopaths employing tractography revealed abnormalities in the right uncinate fasciculus (UF) (Craig et al., 2009), indicating fronto-limbic disconnectivity. However, it is not clear whether WM abnormalities are restricted to this tract or are or more widespread, including other tracts which are involved in connectivity with the frontal lobe. We performed whole brain voxel-based analyses on WM fractional anisotropy (FA) and mean diffusivity (MD) maps acquired with DT-MRI to compare 15 adults with ASPD and healthy age, handedness and IQ-matched controls. Also, within ASPD subjects we related differences in FA and MD to measures of psychopathy. Significant WM FA reduction and MD increases were found respectively in ASPD subjects relative to controls. FA was bilaterally reduced in the genu of corpus callosum while in the right frontal lobe FA reduction was found in the UF, inferior fronto-occipital fasciculus (IFOF), anterior corona radiata and anterior limb and genu of the internal capsule. These differences negatively correlated with measures of psychopathy. Also in the right frontal lobe, increased MD was found in the IFOF and UF, and the corpus callosum and anterior corona radiata. There was a significant positive correlation between MD and psychopathy scores. The present study confirms a previous report of reduced FA in the UF. Additionally, we report for the first time, FA deficits in tracts involved in interhemispheric as well as frontal lobe connectivity in conjunction with MD increases in the frontal lobe. Hence, we provide evidence of significant WM microstructural abnormalities in frontal brain regions in ASPD and psychopathy

  2. MRI in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Kodama, Kazuhiro

    1992-01-01

    The present study investigated magnetic resonance imaging (MRI) features in temporal lobe epilepsy and correlated them with clinical variables, such as age, illness duration, past history, and the frequency of seizure. Cerebral MRI was performed in 45 patients with temporal lobe epilepsy of unknown etiology, using a 0.5 T and/or a 1.5 T MRI systems. The temporal lobe was seen as high signal intensity on T2-weighted images and/or proton density-weighted images in 6 patients, although it was missed on CT and T1-weighted images. The high intensity area seemed to reflect sclerosis of the temporal lobe. This finding was significantly associated with partial seizure. Of these patients, 3 had a history of febrile convulsions. Ten patients had slight dilatation of the inferior horn of the lateral ventricle. They were significantly old at the time of onset and examination, as compared with those without dilatation. Furthermore, 6 patients with unilateral dilatation were significantly younger than the other 4 with bilateral dilatation. Nine patients had small multiple high signal areas in white matter, mainly in the parietal lobe, which suggested vascular origin. These patients were significantly old at the time of onset and examination, as compared with those having no such findings. In depicting high signal intensity areas, a 1.5 T MRI system was not always superior to a 0.5 T MRI system. Proton density-weighted images were better than T2-weighted images in some patients. (N.K.)

  3. Declarative long-term memory and the mesial temporal lobe: Insights from a 5-year postsurgery follow-up study on refractory temporal lobe epilepsy.

    Science.gov (United States)

    Salvato, Gerardo; Scarpa, Pina; Francione, Stefano; Mai, Roberto; Tassi, Laura; Scarano, Elisa; Lo Russo, Giorgio; Bottini, Gabriella

    2016-11-01

    It is largely recognized that the mesial temporal lobe and its substructure support declarative long-term memory (LTM). So far, different theories have been suggested, and the organization of declarative verbal LTM in the brain is still a matter of debate. In the current study, we retrospectively selected 151 right-handed patients with temporal lobe epilepsy with and without hippocampal sclerosis, with a homogeneous (seizure-free) clinical outcome. We analyzed verbal memory performance within a normalized scores context, by means of prose recall and word paired-associate learning tasks. Patients were tested at presurgical baseline, 6months, 2 and 5years after anteromesial temporal lobe surgery, using parallel versions of the neuropsychological tests. Our main finding revealed a key involvement of the left temporal lobe and, in particular, of the left hippocampus in prose recall rather than word paired-associate task. We also confirmed that shorter duration of epilepsy, younger age, and withdrawal of antiepileptic drugs would predict a better memory outcome. When individual memory performance was taken into account, data showed that females affected by left temporal lobe epilepsy for longer duration were more at risk of presenting a clinically pathologic LTM at 5years after surgery. Taken together, these findings shed new light on verbal declarative memory in the mesial temporal lobe and on the behavioral signature of the functional reorganization after the surgical treatment of temporal lobe epilepsy. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Improving the Efficiency of 3-D Hydrogeological Mixers: Dilution Enhancement Via Coupled Engineering-Induced Transient Flows and Spatial Heterogeneity

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe P. J.; Fiori, Aldo; Bellin, Alberto

    2018-03-01

    Natural attenuation and in situ oxidation are commonly considered as low-cost alternatives to ex situ remediation. The efficiency of such remediation techniques is hindered by difficulties in obtaining good dilution and mixing of the contaminant, in particular if the plume deformation is physically constrained by an array of wells, which serves as a containment system. In that case, dilution may be enhanced by inducing an engineered sequence of injections and extractions from such pumping system, which also works as a hydraulic barrier. This way, the aquifer acts as a natural mixer, in a manner similar to the industrialized engineered mixers. Improving the efficiency of hydrogeological mixers is a challenging task, owing to the need to use a 3-D setup while relieving the computational burden. Analytical solutions, though approximated, are a suitable and efficient tool to seek the optimum solution among all possible flow configurations. Here we develop a novel physically based model to demonstrate how the combined spatiotemporal fluctuations of the water fluxes control solute trajectories and residence time distributions and therefore, the effectiveness of contaminant plume dilution and mixing. Our results show how external forcing configurations are capable of inducing distinct time-varying groundwater flow patterns which will yield different solute dilution rates.

  5. A comparative perspective on the human temporal lobe

    NARCIS (Netherlands)

    Bryant, K.L.; Preuss, T.M.; Bruner, E.; Ogihara, N.; Tanabe, H.

    2018-01-01

    The temporal lobe is a morphological specialization of primates resulting from an expansion of higher-order visual cortex that is a hallmark of the primate brain. Among primates, humans possess a temporal lobe that has significantly expanded. Several uniquely human cognitive abilities, including

  6. [Mirror movement due to the medial frontal lobe lesion].

    Science.gov (United States)

    Takahashi, N; Kawamura, M; Hirayama, K

    1995-01-01

    We reported a case with acquired mirror movement in upper limbs due to the lesion of right medial frontal lobe including supplementary motor area, and also discussed a possible mechanism underlying it. A 59-year-old right-handed woman developed left hemiparesis caused by cerebral hemorrhage in the right frontoparietal lobe, on April 5, 1981. She had right hemiparesis and right hemianopsia due to cerebral hemorrhage in the left parieto-occipital lobe, 13 days later. As the patient was recovering from paresis, mirror movement appeared on upper limbs. The features of the mirror movement of this case are summarized as follows: (1) it appeared when using both proximal and distal region of upper limbs; (2) it appeared on left upper limb when the patient intended to move right upper limb or on right upper limb when intended to move left upper limb, while it appeared predominantly in the former; and (3) it was more remarkably found in habitual movement using gesture and pantomimic movement for the use of objects, and it was found in lower degree when actual object was used or when the patient tried to imitate the gesture of the examiner. The lesions in MRI were found in medial region of right frontal lobe (supplementary motor area, medial region of motor area, and cingulate gyrus), right medial parietal lobe, posterior region of right occipital lobe, and medial regions of left parietal and occipital lobes. There was no apparent abnormality in corpus callosum.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Simplified unified analysis of switched-RC passive mixers, samplers, and N -Path filters using the adjoint network

    NARCIS (Netherlands)

    Pavan, Shanthi; Klumperink, Eric A.M.

    2017-01-01

    Recent innovations in software defined CMOS radio transceiver architectures heavily rely on high linearity switched-RC sampler and passive-mixer circuits, driven by digitally programmable multiphase clocks. Although seemingly simple, the frequency domain analysis of these linear periodically time

  8. Papillary thyroid microcarcinoma in a thyroid pyramidal lobe

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Tae Kwan; Kim, Dong Wook; Park, Ha Kyoung; Jung, Soo Jin [Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2014-12-15

    We report an extremely rare case of papillary thyroid microcarcinoma (PTMC) in the thyroid pyramidal lobe (TPL). A 48-year-old woman underwent ultrasound-guided fine-needle aspiration for a small thyroid nodule in the right lobe in local clinic, and it revealed a malignant cytology. On preoperative ultrasonography for tumor staging in our hospital, another small suspiciously malignant hypoechoic nodule was detected in the left TPL. Total thyroidectomy and central nodal dissection were performed. Histopathology confirmed PTMCs in the left TPL and both thyroid lobes. Ultrasonography for TPL should be required for complete evaluation of possible multifocality of thyroid malignancy.

  9. Frontal lobe atrophy of the brain in schizophrenia

    International Nuclear Information System (INIS)

    Hara, Tomio

    1981-01-01

    Reported here are the CT findings on cerebral atrophic lesion chiefly developed in the frontal lobe in schizophrenics with unusual organic encephalopathy. Encephalopathy was recognized in 84 (73%) of 115 schizophrenics and 13 (33%) of 40 neurotics. In an attempt to exclude the effects of aging on encephalopathy, the ages at CT and at the development of disease, the number of morbid years, subtypical schizophrenia and relation between the clinical severity and the atrophic condition were comparatively studied. As a result, cerebral atrophy tended to increase along with aging, but the findings differed in that atrophia classified by age covered the entire brain in general, whereas atrophia in schizophrenics was found in the frontal lobe. In particular, because of the fact that clinical severity and atrophia in the frontal lobe are high correlated and that severe atrophia is recognized even in young people, schizophrenia and atrophia in the frontal lobe are considered to be closely related to each other. It is therefore suggested that the CT findings are useful to clinicians for finding appropriate methods to deal with the prognosis of schizophrenics in their daily diagnosis and for the therapeutic prevention of encephalatrophy by stimulating the frontal lobe, thereby delaying mental deterioration. (author)

  10. Mechatronic thermostatic water mixer for building automation

    Directory of Open Access Journals (Sweden)

    Stefano Mauro

    2015-05-01

    Full Text Available The use of sanitary water is a main aspect of comfort and healthiness within a house or a public environment as gyms or beauty farms. At the same time, water waste should be limited to a minimum in order to preserve both water and the energy required to warm it. To obtain these results, it is necessary to rule quickly and in a precise way the temperature. It is also necessary to check the presence of possible contemporary flow requested by different users in order to optimize distribution in the house network. This work describes a mechatronic water mixer that was developed to ensure fast and precise control of flow and temperature of delivered water. The flow control is based on modulating digital valves driven in pulse code modulation and on a microcontroller board. The electronic unit is designed to interface with a domotic network for remote control and total consumption monitoring and optimization.

  11. Effects of molecular confinement and crowding on horseradish peroxidase kinetics using a nanofluidic gradient mixer.

    Science.gov (United States)

    Wichert, William R A; Han, Donghoon; Bohn, Paul W

    2016-03-07

    The effects of molecular confinement and crowding on enzyme kinetics were studied at length scales and under conditions similar to those found in biological cells. These experiments were carried out using a nanofluidic network of channels constituting a nanofluidic gradient mixer, providing the basis for measuring multiple experimental conditions simultaneously. The 100 nm × 40 μm nanochannels were wet etched directly into borosilicate glass, then annealed and characterized with fluorescein emission prior to kinetic measurements. The nanofluidic gradient mixer was then used to measure the kinetics of the conversion of the horseradish peroxidase (HRP)-catalyzed conversion of non-fluorescent Amplex Red (AR) to the fluorescent product resorufin in the presence of hydrogen peroxide (H2O2). The design of the gradient mixer allows reaction kinetics to be studied under multiple (five) unique solution compositions in a single experiment. To characterize the efficiency of the device the effects of confinement on HRP-catalyzed AR conversion kinetics were studied by varying the starting ratio of AR : H2O2. Equimolar concentrations of Amplex Red and H2O2 yielded the highest reaction rates followed by 2 : 1, 1 : 2, 5 : 1, and finally 1 : 5 [AR] : [H2O2]. Under all conditions, initial reaction velocities were decreased by excess H2O2. Crowding effects on kinetics were studied by increasing solution viscosity in the nanochannels in the range 1.0-1.6 cP with sucrose. Increasing the solution viscosities in these confined geometries decreases the initial reaction velocity at the highest concentration from 3.79 μM min(-1) at 1.00 cP to 0.192 μM min(-1) at 1.59 cP. Variations in reaction velocity are interpreted in the context of models for HRP catalysis and for molecular crowding.

  12. Quantifying interictal metabolic activity in human temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Henry, T.R.; Mazziotta, J.C.; Engel, J. Jr.; Christenson, P.D.; Zhang, J.X.; Phelps, M.E.; Kuhl, D.E.

    1990-01-01

    The majority of patients with complex partial seizures of unilateral temporal lobe origin have interictal temporal hypometabolism on [18F]fluorodeoxyglucose positron emission tomography (FDG PET) studies. Often, this hypometabolism extends to ipsilateral extratemporal sites. The use of accurately quantified metabolic data has been limited by the absence of an equally reliable method of anatomical analysis of PET images. We developed a standardized method for visual placement of anatomically configured regions of interest on FDG PET studies, which is particularly adapted to the widespread, asymmetric, and often severe interictal metabolic alterations of temporal lobe epilepsy. This method was applied by a single investigator, who was blind to the identity of subjects, to 10 normal control and 25 interictal temporal lobe epilepsy studies. All subjects had normal brain anatomical volumes on structural neuroimaging studies. The results demonstrate ipsilateral thalamic and temporal lobe involvement in the interictal hypometabolism of unilateral temporal lobe epilepsy. Ipsilateral frontal, parietal, and basal ganglial metabolism is also reduced, although not as markedly as is temporal and thalamic metabolism

  13. Frontal lobe atrophy in motor neuron diseases.

    Science.gov (United States)

    Kiernan, J A; Hudson, A J

    1994-08-01

    Neuronal degeneration in the precentral gyrus alone cannot account for the occurrence of spastic paresis in motor neuron diseases. To look for more extensive cortical atrophy we measured MRIs of the upper parts of the frontal and parietal lobes in 11 sporadic cases of classical amyotrophic lateral sclerosis (ALS), eight patients with primary lateral sclerosis (PLS) and an age- and sex-matched group of 49 neurologically normal people. None of the patients had overt dementia or other mental diseases. In PLS there is progressive spastic paresis but in contrast to ALS there is no lower motor neuron degeneration. The surface area of the precentral gyri and the amount of underlying white matter in PLS were consistently approximately 75% of the normal size. By contrast, there was some shrinkage of the precentral gyri in some of the ALS patients but the mean measurements for the group did not differ significantly from the controls. Anterior to the precentral sulci, the cortical surface area in PLS was approximately 85% of that of the controls, with correspondingly reduced white matter. In ALS the cortical surface areas of the anterior frontal lobes did not differ from those of the controls, but the amount of underlying white matter was reduced almost as much in ALS as it was in PLS. The measured changes in the frontal lobes suggest that in PLS there is simultaneous atrophy of the primary, premotor and supplementary motor areas of the cortex, with consequent degeneration of corticospinal and corticoreticular axons descending through the underlying white matter. These changes could account for the progressive upper motor neuron syndrome. In ALS, with no significant frontal cortical atrophy, the shrinkage of the white matter may be due to degeneration of axons projecting to the frontal cortex from elsewhere. Deprivation of afferents could explain the diminution of motor functions of the frontal lobes in ALS and also the changes in word fluency, judgement and attention that

  14. Transient simulation in interior flow field of lobe pump

    International Nuclear Information System (INIS)

    Li, Y B; Sang, X H; Shen, H; Jia, K; Meng, Q W

    2013-01-01

    The subject of this paper is mainly focused on the development and control of the double folium and trifolium lobe pump profiles by using the principle of involute engagement and use CAD to get an accurate involute profile. We use the standard k-ε turbulence model and PISO algorithm based on CFD software FLUENT. The dynamic mesh and UDF technology is introduced to simulate the interior flow field inside a lobe pump, and the variation of interior flow field under the condition of the lobe rotating is analyzed. We also analyse the influence produced by the difference in lobes, and then reveal which lobe is best. The results show that dynamic variation of the interior flow field is easily obtained by dynamic mesh technology and the distribution of its pressure and velocity. Because of the small gaps existing between the rotors and pump case, the higher pressure area will flow into the lower area though the small gaps which cause the working area keep with higher pressure all the time. Both of the double folium and trifolium are existing the vortex during the rotting time and its position, size and shape changes all the time. The vortexes even disappear in a circle period and there are more vortexes in double folium lobe pump. The velocity and pressure pulsation of trifolium pump are lower than that of the double folium

  15. Lung lobe collapse: pathophysiology and radiologic significance

    International Nuclear Information System (INIS)

    Lord, P.F.; Gomez, J.A.

    1985-01-01

    The radiographic changes caused by collapse of lung lobes in pulmonary disease, pneumothorax, and pleural effusion depend on the lobar recoiling force and local pleural pressure. Differences in the tendency of normal lung lobes or regions to collapse depend on the relative surface-to-volume ratio, determined by shape and size of the region or lobe. This ratio affects the physiologic parameters of pulmonary interdependence, compliance, and collateral air flow. Pulmonary surfactant increases compliance, particularly at low volumes, maintains alveolar stability, and assists in maintaining capillary patency and preventing pulmonary edema. Its loss due to lung injury increases collapsing forces. In the presence of pneumothorax or pleural effusion, diseases that cause lobar collapse produce localized air or fluid entrapment that is a diagnostic sign of the presence of the underlying pulmonary disease

  16. Infectious Causes of Right Middle Lobe Syndrome.

    Science.gov (United States)

    Rashid, Aatif; Nanjappa, Sowmya; Greene, John N

    2017-01-01

    Right middle lobe (RML) syndrome is defined as recurrent or chronic obstruction or infection of the middle lobe of the right lung. Nonobstructive causes of middle lobe syndrome include inflammatory processes and defects in the bronchial anatomy and collateral ventilation. We report on 2 case patients with RML syndrome, one due to infection with Mycobacterium avium complex followed by M asiaticum infection and the other due to allergic bronchopulmonary aspergillosis. A history of atopy, asthma, or chronic obstructive pulmonary disease has been reported in up to one-half of those with RML. The diagnosis can be made by plain radiography, computed tomography, and bronchoscopy. Medical treatment consists of bronchodilators, mucolytics, and antimicrobials. Patients whose disease is unresponsive to treatment and those with obstructive RML syndrome can be offered surgical treatment.

  17. Longer epilepsy duration and multiple lobe involvement predict worse seizure outcomes for patients with refractory temporal lobe epilepsy associated with neurocysticercosis

    Directory of Open Access Journals (Sweden)

    Lucas Crociati Meguins

    2015-12-01

    Full Text Available ABSTRACT Objective To investigate the surgical outcomes of temporal lobe epilepsy associated with hippocampal sclerosis (TLE-HS and neurocysticercosis (NCC. Methods A retrospective investigation of patients with TLE-HS was conducted in a tertiary center. Results Seventy-nine (62.2%, 37 (29.1%, 6 (4.7%, and 5 (3.9% patients were Engel class I, II, III, and IV, respectively. Fifty-two (71.2% patients with epilepsy durations ≤ 10 years prior to surgery were seizure-free 1 year after the operation compared to 27 (50.0% patients with epilepsy durations > 10 years (p = 0.0121. Forty-three (72.9% patients with three or fewer lobes affected by NCC were seizure-free one year after the operation, and 36 (52.9% patients with more than three involved lobes were seizure-free after surgery (p = 0.0163. Conclusions Longer epilepsy durations and multiple lobe involvement predicted worse seizure outcomes in TLE-HS plus NCC patients.

  18. Centrifugal acceleration in the magnetotail lobes

    Directory of Open Access Journals (Sweden)

    H. Nilsson

    2010-02-01

    Full Text Available Combined Cluster EFW and EDI measurements have shown that cold ion outflow in the magnetospheric lobes dominates the hydrogen ion outflow from the Earth's atmosphere. The ions have too low kinetic energy to be measurable with particle instruments, at least for the typical spacecraft potential of a sunlit spacecraft in the tenuous lobe plasmas outside a few RE. The measurement technique yields both density and bulk velocity, which can be combined with magnetic field measurements to estimate the centrifugal acceleration experienced by these particles. We present a quantitative estimate of the centrifugal acceleration, and the velocity change with distance which we would expect due to centrifugal acceleration. It is found that the centrifugal acceleration is on average outward with an average value of about of 5 m s−2. This is small, but acting during long transport times and over long distances the cumulative effect is significant, while still consistent with the relatively low velocities estimated using the combination of EFW and EDI data. The centrifugal acceleration should accelerate any oxygen ions in the lobes to energies observable by particle spectrometers. The data set also put constraints on the effectiveness of any other acceleration mechanisms acting in the lobes, where the total velocity increase between 5 and 19 RE geocentric distance is less than 5 km s−1.

  19. An experimentally validated DEM study of powder mixing in a paddle blade mixer

    OpenAIRE

    Pantaleev, Stefan; Yordanova, Slavina; Janda, Alvaro; Marigo, Michele; Ooi, Jin

    2017-01-01

    An investigation on the predictive capabilities of Discrete Element Method simulations of a powder mixing process in a laboratory scale paddle blade mixer is presented. The visco-elasto-plastic frictional adhesive DEM contactmodel of Thakur et al. (2014) was used to represent the cohesive behaviour of an aluminosilicate powder in which the model parameters were determined using experimental flow energy measurements from the FT4powder rheometer. DEM simulations of the mixing process using the ...

  20. Papillary thyroid microcarcinoma in a thyroid pyramidal lobe

    Directory of Open Access Journals (Sweden)

    Tae Kwun Ha

    2014-10-01

    Full Text Available

    We report an extremely rare case of papillary thyroid microcarcinoma (PTMC in the thyroid Epub ahead of print pyramidal lobe (TPL. A 48-year-old woman underwent ultrasound-guided fine-needle aspiration for a small thyroid nodule in the right lobe in local clinic, and it revealed a malignant cytology. On preoperative ultrasonography for tumor staging in our hospital, another small suspiciously malignant hypoechoic nodule was detected in the left TPL. Total thyroidectomy and central nodal dissection were performed. Histopathology confirmed PTMCs in the left TPL and both thyroid lobes. Ultrasonography for TPL should be required for complete evaluation of possible multifocality of thyroid malignancy.

  1. An Efficient Approach for Identifying Stable Lobes with Discretization Method

    Directory of Open Access Journals (Sweden)

    Baohai Wu

    2013-01-01

    Full Text Available This paper presents a new approach for quick identification of chatter stability lobes with discretization method. Firstly, three different kinds of stability regions are defined: absolute stable region, valid region, and invalid region. Secondly, while identifying the chatter stability lobes, three different regions within the chatter stability lobes are identified with relatively large time intervals. Thirdly, stability boundary within the valid regions is finely calculated to get exact chatter stability lobes. The proposed method only needs to test a small portion of spindle speed and cutting depth set; about 89% computation time is savedcompared with full discretization method. It spends only about10 minutes to get exact chatter stability lobes. Since, based on discretization method, the proposed method can be used for different immersion cutting including low immersion cutting process, the proposed method can be directly implemented in the workshop to promote machining parameters selection efficiency.

  2. A 38 to 44GHz sub-harmonic balanced HBT mixer with integrated miniature spiral type marchand balun

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor

    2013-01-01

    This work presents an active balanced sub-harmonic mixer (SHM) using InP double heterojunction bipolar transistor technology (DHBT) for Q-band applications. A miniature spiral type Marchand balun with five added capacitances for improved control of amplitude and phase balance is integrated with t...

  3. The use of a continuous-action centrifugal-screw mixer for improving the quality of flour baking mixes for functional purposes

    Directory of Open Access Journals (Sweden)

    D. M. Borodulin

    2018-01-01

    Full Text Available The influence of the number of screw turns of a centrifugal-screw mixer, the number of holes in the screw turns and the rotor speed on the quality of mixing of flour baking mixes of functional purpose enriched with amino acids was studied. Flour baking mix is composed of wheat flour, whole wheat flour, chickpeas flour, rye flour, buckwheat flour, oat bran, gluten, dry milk powder, sesame seeds, flax seed, dried onions, table salt and sugar. The homogeneity of the mixture reflects table salt because it has a minimal weight relative to other components of the mix. The coefficient of heterogeneity was calculated to assess the quality of mixing. The centrifugal-screw mixer optimal operation parameters were investigated for different flour baking mixes. For the mix № 1 and mix № 2 optimal parameters are rotor rotating speed of 900 rpm, the number of turns of the screw 4 and the number of holes on the threads of the screw 4. For the mix № 3 optimal parameters are rotor speed of 500 rpm, the number of turns of the screw 2 and the number of holes on the threads of the screw 8. The centrifugal–screw mixer allow to obtain enriched with amino acids flour baking mix of good quality. The coefficient of heterogeneity of mixes does not exceed 5%. For all samples of bread amino acid content is significantly higher compared to the control sample. Depending on the bread recipe contents of amino acids increased by 83–97% for arginine, 52–61% for tyrosine, 52–66% for phenylalanine, 72–74% for histidine, 91% for leucine+ isoleucine, 53–56% for methionine, 90–97% for valine, 64–72% for proline, 87–93% for threonine, 58–87% for serine and 74% for alanine. The greatest biological value is attributed to flour the baking mix № 1 and № 2. The economic effect of selling an enriched flour bakery mixture prepared on a centrifugal–screw mixer has been determined. It is established that the operating costs for the production of 1 kg of such

  4. A 5.4mW GPS CMOS quadrature front-end based on a single-stage LNA-mixer-VCO

    DEFF Research Database (Denmark)

    Liscidini, Amtonio; Mazzanti, Andrea; Tonietto, Riccardo

    2006-01-01

    A GPS RF front-end combines the LNA, mixer, and VCO in a single stage and can operate from a 1.2V supply. The chip is implemented in a 0.13um CMOS process and occupies 1.5mm2 active area. It consumes 5.4mW with a 4.8dB NF, 36dB gain, and a P1dB of -31dBm.......A GPS RF front-end combines the LNA, mixer, and VCO in a single stage and can operate from a 1.2V supply. The chip is implemented in a 0.13um CMOS process and occupies 1.5mm2 active area. It consumes 5.4mW with a 4.8dB NF, 36dB gain, and a P1dB of -31dBm....

  5. A multi-purpose ultrasonic streaming mixer for integrated magnetic bead ELISAs

    International Nuclear Information System (INIS)

    Brandhoff, Lukas; Lang, Walter; Vellekoop, Michael J; Zirath, Helene; Peham, Johannes; Wiesinger-Mayr, Herbert; Salas, Mariugenia; Haller, Anna; Spittler, Andreas; Schnetz, Guntram

    2015-01-01

    We present an ultrasonic streaming mixer for disposable and on-chip magnetic bead ELISAs. The ultrasonic transducer is placed at system-level to keep cost per chip as low as possible, and is coupled to the chip by means of a solid ultrasonic horn. The system provides mixing of liquids, as well as dispersion of the superparamagnetic beads in the ELISA. Additionally it can be used clean the chamber surface from nonspecifically bound proteins during the washing steps in the ELISA protocol. Using our system the time for the ELISA protocol has been greatly reduced down to 30 min. (paper)

  6. High-T{sub c} superconducting Josephson mixers for terahertz heterodyne detection

    Energy Technology Data Exchange (ETDEWEB)

    Malnou, M.; Feuillet-Palma, C.; Olanier, L.; Lesueur, J.; Bergeal, N. [Laboratoire de Physique et d' Etude des Matériaux—UMR8213-CNRS-ESPCI ParisTech-UPMC-PSL university, 10 Rue Vauquelin—75005 Paris (France); Ulysse, C.; Faini, G. [Laboratoire de Photonique et de Nanostructures LPN-CNRS, Route de Nozay, 91460 Marcoussis (France); Febvre, P. [IMEP-LAHC—UMR 5130 CNRS, Université de Savoie, 73376 Le Bourget du Lac cedex (France); Sirena, M. [Centro Atómico Bariloche, Instituto Balseiro—CNEA and Univ. Nac. de Cuyo, Av. Bustillo 9500, 8400 Bariloche, Rio Negro (Argentina)

    2014-08-21

    We report on an experimental and theoretical study of the high-frequency mixing properties of ion-irradiated YBa{sub 2}Cu{sub 3}O{sub 7} Josephson junctions embedded in THz antennas. We investigated the influence of the local oscillator power and frequency on the device performances. The experimental data are compared with theoretical predictions of the general three-port model for mixers in which the junction is described by the resistively shunted junction model. A good agreement is obtained for the conversion efficiency in different frequency ranges, spanning above and below the characteristic frequencies f{sub c} of the junctions.

  7. Metabolic changes in occipital lobe epilepsy with automatisms.

    Science.gov (United States)

    Wong, Chong H; Mohamed, Armin; Wen, Lingfeng; Eberl, Stefan; Somerville, Ernest; Fulham, Michael; Bleasel, Andrew F

    2014-01-01

    Some studies suggest that the pattern of glucose hypometabolism relates not only to the ictal-onset zone but also reflects seizure propagation. We investigated metabolic changes in patients with occipital lobe epilepsy (OLE) that may reflect propagation of ictal discharge during seizures with automatisms. Fifteen patients who had undergone epilepsy surgery for intractable OLE and had undergone interictal Fluorine-18-fluorodeoxyglucose positron-emission tomography ((18)F-FDG-PET) between 1994 and 2004 were divided into two groups (with and without automatisms during seizure). Significant regions of hypometabolism were identified by comparing (18)F-FDG-PET results from each group with 16 healthy controls by using statistical parametric mapping. Significant hypometabolism was confined largely to the epileptogenic occipital lobe in the patient group without automatisms. In patients with automatisms, glucose hypometabolism extended from the epileptogenic occipital lobe into the ipsilateral temporal lobe. We identified a distinctive hypometabolic pattern that was specific for OLE patients with automatisms during a seizure. This finding supports the postulate that seizure propagation is a cause of glucose hypometabolism beyond the region of seizure onset.

  8. Mirror focus in a patient with intractable occipital lobe epilepsy.

    Science.gov (United States)

    Kim, Jiyoung; Shin, Hae Kyung; Hwang, Kyoung Jin; Choi, Su Jung; Joo, Eun Yeon; Hong, Seung Bong; Hong, Seung Chul; Seo, Dae-Won

    2014-06-01

    Mirror focus is one of the evidence of progression in epilepsy, and also has practical points for curative resective epilepsy surgery. The mirror foci are related to the kindling phenomena that occur through interhemispheric callosal or commissural connections. A mirror focus means the secondary epileptogenic foci develop in the contralateral hemispheric homotopic area. Thus mirror foci are mostly reported in patients with temporal or frontal lobe epilepsy, but not in occipital lobe epilepsy. We have observed occipital lobe epilepsy with mirror focus. Before epilepsy surgery, the subject's seizure onset zone was observed in the left occipital area by ictal studies. Her seizures abated for 10 months after the resection of left occipital epileptogenic focus, but recurred then. The recurred seizures were originated from the right occipital area which was in the homotopic contralateral area. This case can be an evidence that occipital lobe epilepsy may have mirror foci, even though each occipital lobe has any direct interhemispheric callosal connections between them.

  9. Frontal Lobe Contusion in Mice Chronically Impairs Prefrontal-Dependent Behavior.

    Directory of Open Access Journals (Sweden)

    Austin Chou

    Full Text Available Traumatic brain injury (TBI is a major cause of chronic disability in the world. Moderate to severe TBI often results in damage to the frontal lobe region and leads to cognitive, emotional, and social behavioral sequelae that negatively affect quality of life. More specifically, TBI patients often develop persistent deficits in social behavior, anxiety, and executive functions such as attention, mental flexibility, and task switching. These deficits are intrinsically associated with prefrontal cortex (PFC functionality. Currently, there is a lack of analogous, behaviorally characterized TBI models for investigating frontal lobe injuries despite the prevalence of focal contusions to the frontal lobe in TBI patients. We used the controlled cortical impact (CCI model in mice to generate a frontal lobe contusion and studied behavioral changes associated with PFC function. We found that unilateral frontal lobe contusion in mice produced long-term impairments to social recognition and reversal learning while having only a minor effect on anxiety and completely sparing rule shifting and hippocampal-dependent behavior.

  10. Altered organization of face processing networks in temporal lobe epilepsy

    Science.gov (United States)

    Riley, Jeffrey D.; Fling, Brett W.; Cramer, Steven C.; Lin, Jack J.

    2015-01-01

    SUMMARY Objective Deficits in social cognition are common and significant in people with temporal lobe epilepsy (TLE), but the functional and structural underpinnings remain unclear. The present study investigated how the side of seizure focus impacts face processing networks in temporal lobe epilepsy. Methods We used functional magnetic resonance imaging (fMRI) of a face processing paradigm to identify face responsive regions in 24 individuals with unilateral temporal lobe epilepsy (Left = 15; Right = 9) and 19 healthy controls. fMRI signals of face responsive regions ispilateral and contralateral to the side of seizure onset were delineated in TLE and compared to the healthy controls with right and left side combined. Diffusion tensor images were acquired to investigate structural connectivity between face regions that differed in fMRI signals between the two groups. Results In temporal lobe epilepsy, activation of the cortical face processing networks varied according to side of seizure onset. In temporal lobe epilepsy, the laterality of amygdala activation was shifted to the side contralateral to the seizure focus while controls showed no significant asymmetry. Furthermore, compared to controls, patients with TLE showed decreased activation of the occipital face responsive region in the ipsilateral side and an increased activity of the anterior temporal lobe in the contralateral side to the seizure focus. Probabilistic tractography revealed that the occipital face area and anterior temporal lobe are connected via the inferior longitudinal fasciculus, which in individuals with temporal lobe epilepsy showed reduced integrity. Significance Taken together, these findings suggest that brain function and white matter integrity of networks subserving face processing are impaired on the side of seizure onset, accompanied by altered responses on the side contralateral to the seizure. PMID:25823855

  11. Visuo-spatial construction in patients with frontal and parietal lobe lesions

    Directory of Open Access Journals (Sweden)

    Himani Kashyap

    2011-04-01

    Full Text Available Visuospatial construction, traditionally viewed as a putative parietal function, also requires sustained attention, planning, organization strategies and error correction, and hence frontal lobe mediation. The relative contributions of the frontal and parietal lobes are poorly understood. To examine the contributions of parietal, frontal lobes, as well as right and left cerebral hemispheres to visuospatial construction. The Stick Construction Test for two-dimensional construction and the Block Construction Test for three-dimensional construction were administered pre-surgically to patients with lesions in the parietal lobe (n =9 and the frontal lobe (n=11, along with normal control subjects (n =20 matched to the patients on age (+/- 3 years, gender, education (+/- 3 years and handedness. The patients were significantly slower than the controls on both two-dimensional and three-dimensional tests. Patients with parietal lesions were slower than those with frontal lesions on the test of three-dimensional construction. Within each lobe patients with right and left sided lesions did not differ significantly. It appears that tests of three-dimensional construction might be most sensitive to visuospatial construction deficits. Visuospatial construction involves the mediation of both frontal and parietal lobes. The function does not appear to be lateralized. The networks arising from the parieto-occipital areas and projecting to the frontal cortices (e.g., occipito-frontal fasciculus may be the basis of the mediation of both lobes in visuospatial construction. The present findings need replication from studies with larger sample sizes.

  12. A Handheld LED Coloured-Light Mixer for Students to Learn Collaboratively the Primary Colours of Light

    Science.gov (United States)

    Nopparatjamjomras, Suchai; Chitaree, Ratchapak; Panijpan, Bhinyo

    2009-01-01

    To overcome students' inaccurate prior knowledge on primary additive colours, a coloured-light mixer has been constructed to enable students to observe directly the colours produced and reach the conclusion by themselves that the three primary colours of light are red, green, and blue (NOT red, yellow, and blue). Three closely packed tiny…

  13. Magnetic resonance tomography (MRT) for lesions of the temporal lobes

    International Nuclear Information System (INIS)

    Schoerner, W.; Felix, R.; Meencke, H.J.; Freie Univ. Berlin; Freie Univ. Berlin

    1985-01-01

    A comparative study between magnetic resonance tomography (MRT) and CT was carried out in 16 patients with temporal lobe epilepsy. The MRT studies were performed on a 0.35 T Magnetom with T.1 modes in a coronal plane. MRT proved to the superior to CT. CT demonstrated a discrete temporal lobe lesion in three patients and MRT in four patients. In addition, unilateral atrophy of the temporal lobe was demonstrated by MRT in six cases; these could not be diagnosed by CT. The lack of artifacts near the skull base, the possibility of producing coronal sections and the excellent tissue differential of MRT provide the basis for improved diagnosis of lesions in the temporal lobes. (orig.) [de

  14. Craniopharyngioma in the temporal lobe: a case report

    International Nuclear Information System (INIS)

    Sohn, Chul-Ho; Baik, Seung-Kug; Kim, Sang-Pyo; Kim, Il-Man; Sevick, Robert J.

    2004-01-01

    Herein, we report on an unusual case of craniopharyngioma arising in the temporal lobe with no prior history of surgery and with no connection to the craniopharyngeal duct. MR images showed cystic tumor with a small solid portion. To the best of our knowledge, this is the first case of a craniopharyngioma occurring in the temporal lobe

  15. Craniopharyngioma in the temporal lobe: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Chul-Ho; Baik, Seung-Kug; Kim, Sang-Pyo; Kim, Il-Man; Sevick, Robert J. [University of Calgary, Calgary (Canada)

    2004-03-15

    Herein, we report on an unusual case of craniopharyngioma arising in the temporal lobe with no prior history of surgery and with no connection to the craniopharyngeal duct. MR images showed cystic tumor with a small solid portion. To the best of our knowledge, this is the first case of a craniopharyngioma occurring in the temporal lobe.

  16. Temporal Lobe Epilepsy in Children

    Science.gov (United States)

    Nickels, Katherine C.; Wong-Kisiel, Lily C.; Moseley, Brian D.; Wirrell, Elaine C.

    2012-01-01

    The temporal lobe is a common focus for epilepsy. Temporal lobe epilepsy in infants and children differs from the relatively homogeneous syndrome seen in adults in several important clinical and pathological ways. Seizure semiology varies by age, and the ictal EEG pattern may be less clear cut than what is seen in adults. Additionally, the occurrence of intractable seizures in the developing brain may impact neurocognitive function remote from the temporal area. While many children will respond favorably to medical therapy, those with focal imaging abnormalities including cortical dysplasia, hippocampal sclerosis, or low-grade tumors are likely to be intractable. Expedient workup and surgical intervention in these medically intractable cases are needed to maximize long-term developmental outcome. PMID:22957247

  17. Versive seizures in occipital lobe epilepsy: lateralizing value and pathophysiology.

    Science.gov (United States)

    Usui, Naotaka; Mihara, Tadahiro; Baba, Koichi; Matsuda, Kazumi; Tottori, Takayasu; Umeoka, Shuichi; Kondo, Akihiko; Nakamura, Fumihiro; Terada, Kiyohito; Usui, Keiko; Inoue, Yushi

    2011-11-01

    To clarify the value of versive seizures in lateralizing and localizing the epileptogenic zone in patients with occipital lobe epilepsy, we studied 13 occipital lobe epilepsy patients with at least one versive seizure recorded during preoperative noninvasive video-EEG monitoring, who underwent occipital lobe resection, and were followed postoperatively for more than 2 years with Engel's class I outcome. The videotaped versive seizures were analyzed to compare the direction of version and the side of surgical resection in each patient. Moreover, we examined other motor symptoms (partial somatomotor manifestations such as tonic and/or clonic movements of face and/or limbs, automatisms, and eyelid blinking) associated with version. Forty-nine versive seizures were analyzed. The direction of version was always contralateral to the side of resection except in one patient. Among accompanying motor symptoms, partial somatomotor manifestations were observed in only five patients. In conclusion, versive seizure is a reliable lateralizing sign indicating contralateral epileptogenic zone in occipital lobe epilepsy. Since versive seizures were accompanied by partial somatomotor manifestations in less than half of the patients, it is suggested that the mechanism of version in occipital lobe epilepsy is different from that in frontal lobe epilepsy. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. The probabilistic model of the process mixing of animal feed ingredients into a continuous mixer-reactor

    Directory of Open Access Journals (Sweden)

    L. I. Lytkina

    2016-01-01

    Full Text Available A mathematical model of the polydisperse medium mixing process reflects its stochastic features in the form of uneven distribution of phase elements on the time of their presence in apparatus, particle size, ripple retention of the apparatus, random distribution of the material and thermal phase flows of the working volume, heterogeneity of the medium physical- and chemical properties, complicated by chemical reaction. For the mathematical description of the mixing process of animal feed ingredients in the presence of chemical reaction the system of differential equations of Academician V.V. Kafarov was used. Proposed by him hypothesis based on the theory of Markov’s processes stating that "any multicomponent mixture can be considered as the result of an iterative process of mixing the two components to achieve the desired uniformity of all the ingredients in the mixture" allows us to consider a process of mixing binary composition in a paddle mixer in the form of differential equations of two ingredients concentration numerous changes until it becomes a homogenous mixture. It was found out that the mixing process of the two-component mixture is determined in a paddle mixer with a constant mixing speed and a limit (equilibrium dispersion of the ingredients in the mixture i.e. with its uniformity. Adjustment of the model parameters was carried out according to the results of experimental studies on mixing the crushed wheat with metallomagnetic impurity, which was a key (indicator component. According to the best values of the constant of the continuous mixing speed and the equilibrium disperse values of the ingredients contents, the mathematical model parameters identification was carried out. The results obtained are used to develop a new generation mixer design.

  19. Hanford high level waste (HLW) tank mixer pump safe operating envelope reliability assessment

    International Nuclear Information System (INIS)

    Fischer, S.R.; Clark, J.

    1993-01-01

    The US Department of Energy and its contractor, Westinghouse Corp., are responsible for the management and safe storage of waste accumulated from processing defense reactor irradiated fuels for plutonium recovery at the Hanford Site. These wastes, which consist of liquids and precipitated solids, are stored in underground storage tanks pending final disposition. Currently, 23 waste tanks have been placed on a safety watch list because of their potential for generating, storing, and periodically releasing various quantities of hydrogen and other gases. Tank 101-SY in the Hanford SY Tank Farm has been found to release hydrogen concentrations greater than the lower flammable limit (LFL) during periodic gas release events. In the unlikely event that an ignition source is present during a hydrogen release, a hydrogen burn could occur with a potential to release nuclear waste materials. To mitigate the periodic gas releases occurring from Tank 101-SY, a large mixer pump currently is being installed in the tank to promote a sustained release of hydrogen gas to the tank dome space. An extensive safety analysis (SA) effort was undertaken and documented to ensure the safe operation of the mixer pump after it is installed in Tank 101-SY.1 The SA identified a need for detailed operating, alarm, and abort limits to ensure that analyzed safety limits were not exceeded during pump operations

  20. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    International Nuclear Information System (INIS)

    WHITE, D.A.

    1999-01-01

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS)

  1. Cognitive dysfunctions in occipital lobe epilepsy compared to temporal lobe epilepsy.

    Science.gov (United States)

    Santangelo, Gabriella; Trojano, Luigi; Vitale, Carmine; Improta, Ilaria; Alineri, Irma; Meo, Roberta; Bilo, Leonilda

    2017-06-01

    To compare cognitive profiles of occipital lobe epilepsy (OLE) and temporal lobe epilepsy (TLE) and to investigate whether impairment of visuospatial functions is a specific deficit of OLE. Eighteen patients with OLE, 18 patients with TLE, and 18 controls underwent a neuropsychological battery assessing memory, visuospatial functions, and frontal/executive functions. Multivariate analysis evidenced poorer performance of patients with TLE and patients with OLE relative to controls on tasks assessing verbal and non-verbal long-term memory, frontal functions, and visuospatial functions. Patients with OLE had poorer performance than patients with TLE on visuospatial tasks, whereas patients with TLE performed worse than patients with OLE on verbal long-term memory test. Discriminant analysis identified two canonical discriminant functions: The first explained 53.3% of the variance, and the second explained 46.7% of the variance. The first function included verbal and non-verbal memory tests distinguishing controls from both OLE and TLE, whereas the second factor including a visuoconstructional test distinguished OLE from TLE and controls. The results demonstrate that visuoconstructional dysfunction is related to OLE and support the idea that alterations of occipito-parietal stream may be specific to patients with OLE. © 2015 The British Psychological Society.

  2. Intrinsic controls on the range of volumes, morphologies, and dimensions of submarine lobes

    Science.gov (United States)

    Prélat, A.; Covault, J. A.; Hodgson, D. M.; Fildani, A.; Flint, S. S.

    2010-12-01

    Submarine lobe dimensions from six different systems are compared: 1) the exhumed Permian Fan 3 lobe complex of the Tanqua Karoo, South Africa; 2) the modern Amazon fan channel-mouth lobe complex, offshore Brazil; 3) a portion of the modern distal Zaïre fan, offshore Angola/Congo; 4) a Pleistocene fan of the Kutai basin, subsurface offshore Indonesia; 5) the modern Golo system, offshore east Corsica, France; and 6) a shallow subsurface lobe complex , offshore Nigeria. These six systems have significantly different source-to-sink configurations (shelf dimension and slope topography), sediment supply characteristics (available grain size range and supply rate), tectonic settings, (palaeo) latitude, and delivery systems. Despite these differences, lobe deposits share similar geometric and dimensional characteristics. Lobes are grouped into two distinct populations of geometries that can be related to basin floor topography. The first population corresponds to areally extensive but thin lobes (average width 14 km × length 35 km × thickness 12 m) that were deposited onto low relief basin floor areas. Examples of such systems include the Tanqua Karoo, the Amazon, and the Zaïre systems. The second population corresponds to areally smaller but thicker lobes (average width 5 km × length 8 km × thickness 30 m) that were deposited into settings with higher amplitude of relief, like in the Corsican trough, the Kutai basin, and offshore Nigeria. The two populations of lobe types, however, share similar volumes (a narrow range around 1 or 2 km 3), which suggests that there is a control to the total volume of sediment that individual lobes can reach before they shift to a new locus of deposition. This indicates that the extrinsic processes control the number of lobes deposited per unit time rather than their dimensions. Two alternative hypotheses are presented to explain the similarities in lobe volumes calculated from the six very different systems. The first states that

  3. Evaluation of Flygt Propeller Mixers for Double-Shell Tank (DST) High Level Waste Auxiliary Solids Mobilization

    International Nuclear Information System (INIS)

    PACQUET, E.A.

    2000-01-01

    The River Protection Project (RPP) is planning to retrieve radioactive waste from the single-shell tanks (SST) and double-shell tanks (DST) underground at the Hanford Site. This waste will then be transferred to a waste treatment plant to be immobilized (vitrified) in a stable glass form. Over the years, the waste solids in many of the tanks have settled to form a layer of sludge at the bottom. The thickness of the sludge layer varies from tank to tank, from no sludge or a few inches of sludge to about 15 ft of sludge. The purpose of this technology and engineering case study is to evaluate the Flygt(trademark) submersible propeller mixer as a potential technology for auxiliary mobilization of DST HLW solids. Considering the usage and development to date by other sites in the development of this technology, this study also has the objective of expanding the knowledge base of the Flygt(trademark) mixer concept with the broader perspective of Hanford Site tank waste retrieval. More specifically, the objectives of this study delineated from the work plan are described

  4. Craniopharyngioma in the Temporal Lobe: A Case Report

    Science.gov (United States)

    Baik, Seung Kug; Kim, Sang-Pyo; Kim, Il-Man; Sevick, Robert J.

    2004-01-01

    Herein, we report on an unusual case of craniopharyngioma arising in the temporal lobe with no prior history of surgery and with no connection to the craniopharyngeal duct. MR images showed a cystic tumor with a small solid portion. To the best of our knowledge, this is the first case of a craniopharyngioma occurring in the temporal lobe. PMID:15064562

  5. Gangliogliomas: characteristic imaging findings and role in the temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Y; Yagishita, A [Tokyo Metropolitan Neurological Hospital, Department of Neuroradiology, Tokyo (Japan)

    2008-10-15

    Ganglioglioma is an uncommon neoplasm of the central nervous system, most frequently seen in the temporal lobe, and usually associated with medically refractory epilepsy in children and young adults. Few reports have considered ganglioglioma-associated epileptogenicity arising in the temporal lobe. The purpose of our study was to define the imaging features of ganglioglioma in the temporal lobe and their relation to the seizure foci revealed by electrocorticograms. We reviewed 24 patients with pathologically confirmed ganglioglioma in the temporal lobe. Computed tomography (CT) images showed gangliogliomas to be isodense (91.7%), and on T1-weighted images (T1-WI) most gangliogliomas (79.2%) were isointense to the gray matter. A cystic lesion was seen in 14 of 24 of the gangliogliomas (58.3%). Mass effects were not seen in any of the ten tumors without cystic components. One patient showed tumor recurrence. Dual pathology was seen in two cases (8.3%). In 23 cases, epileptogenicity was confirmed in the tumors by intraoperative electrocorticogram. The remaining case had no epileptogenicity. A tumor presenting isointensity to gray matter on T1-WI without mass effects in the medial temporal lobe in a young patient with temporal lobe epilepsy (TLE) might be the characteristic imaging of temporal lobe ganglioglioma. However, such tumors are not always associated with epileptogenicity, even if a ganglioglioma is found in a patient with TLE. The seizure foci may be contralateral to the ganglioglioma. Therefore, we need to investigate the hippocampus, white matter abnormalities of the ipsilateral and contralateral anterior temporal lobe, and other focal lesions closely. (orig.)

  6. Gangliogliomas: characteristic imaging findings and role in the temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Adachi, Y.; Yagishita, A.

    2008-01-01

    Ganglioglioma is an uncommon neoplasm of the central nervous system, most frequently seen in the temporal lobe, and usually associated with medically refractory epilepsy in children and young adults. Few reports have considered ganglioglioma-associated epileptogenicity arising in the temporal lobe. The purpose of our study was to define the imaging features of ganglioglioma in the temporal lobe and their relation to the seizure foci revealed by electrocorticograms. We reviewed 24 patients with pathologically confirmed ganglioglioma in the temporal lobe. Computed tomography (CT) images showed gangliogliomas to be isodense (91.7%), and on T1-weighted images (T1-WI) most gangliogliomas (79.2%) were isointense to the gray matter. A cystic lesion was seen in 14 of 24 of the gangliogliomas (58.3%). Mass effects were not seen in any of the ten tumors without cystic components. One patient showed tumor recurrence. Dual pathology was seen in two cases (8.3%). In 23 cases, epileptogenicity was confirmed in the tumors by intraoperative electrocorticogram. The remaining case had no epileptogenicity. A tumor presenting isointensity to gray matter on T1-WI without mass effects in the medial temporal lobe in a young patient with temporal lobe epilepsy (TLE) might be the characteristic imaging of temporal lobe ganglioglioma. However, such tumors are not always associated with epileptogenicity, even if a ganglioglioma is found in a patient with TLE. The seizure foci may be contralateral to the ganglioglioma. Therefore, we need to investigate the hippocampus, white matter abnormalities of the ipsilateral and contralateral anterior temporal lobe, and other focal lesions closely. (orig.)

  7. Spectrometric Analysis for Pulse Jet Mixer Testing

    International Nuclear Information System (INIS)

    ZEIGLER, KRISTINE

    2004-01-01

    The Analytical Development Section (ADS) was tasked with providing support for a Hanford River Protection Program-Waste Treatment Program (RPP-WTP) project test involving absorption analysis for non-Newtonian pulse jet mixer testing for small scale (PJM) and prototype (CRV) tanks with sparging. Tanks filled with clay were mixed with various amounts of powdered dye as a tracer. The objective of the entire project was to determine the best mixing protocol (nozzle velocity, number of spargers used, total air flow, etc.) by determining the percent mixed volume through the use of an ultraviolet-visible (UV-Vis) spectrometer. The dye concentration within the sample could be correlated to the volume fraction mixed in the tank. Samples were received in vials, a series of dilutions were generated from the clay, allowed to equilibrate, then centrifuged and siphoned for the supernate liquid to analyze by absorption spectroscopy. Equilibration of the samples and thorough mixing of the samples were a continuous issue with dilution curves being difficult to obtain. Despite these technical issues, useful data was obtained for evaluation of various mix conditions

  8. Sodium confluent rates of flow values, on 0,5 mixer, of a sodium italian SS-050 circuit component

    International Nuclear Information System (INIS)

    Walsh, L.M.

    1987-01-01

    Sodium lines on different temperatures, during an emergency drainage on 0,5 mixer was found. To future valuation by DIMEC of tensions that occurs on that component of SS-050, the confluent rates of flow values were calculated. (L.M.J.) [pt

  9. Design of a broadband passive X-band double-balanced mixer in SiGe HBT technology

    DEFF Research Database (Denmark)

    Michaelsen, Rasmus Schandorph; Johansen, Tom Keinicke; Tamborg, Kjeld M.

    2014-01-01

    ) and the radio frequency (RF) port. A break out of the Marchand balun is measured. This demonstrates good phase and magnitude match of 0.7° and 0.11 dB, respectively. The Marchand baluns are broadband with a measured 3 dB bandwidth of 6.4 GHz, while still having a magnitude imbalance better than 0.4 d...... frequency of 8.5 GHz is −9.8 dB at an LO drive level of 15 dBm. The whole mixer is very broadband with 3 dB bandwidth from 7 to 12 GHz covering the entire X-band. The LO–IF, RF–IF, and RF–LO isolation is better than 46, 36, and 36 dB, respectively, in the entire band of operation.......B and a phase imbalance better than 5°. Unfortunately with a rather high loss of 2.5 dB, mainly due to the low Q-factor of the inductors used. The mixer is optimized for use in doppler radars and is highly linear with a 1 dB compression point above 12 dBm IIP2 of 66 dBm. The conversion gain at the center...

  10. Oxide_Oxide Ceramic Matrix Composite (CMC) Exhaust Mixer Development in the NASA Environmentally Responsible Aviation (ERA) Project

    Science.gov (United States)

    Kiser, J. Douglas; Bansal, Narottam P.; Szelagowski, James; Sokhey, Jagdish; Heffernan, Tab; Clegg, Joseph; Pierluissi, Anthony; Riedell, Jim; Wyen, Travis; Atmur, Steven; hide

    2015-01-01

    LibertyWorks®, a subsidiary of Rolls-Royce Corporation, first studied CMC (ceramic matrix composite) exhaust mixers for potential weight benefits in 2008. Oxide CMC potentially offered weight reduction, higher temperature capability, and the ability to fabricate complex-shapes for increased mixing and noise suppression. In 2010, NASA was pursuing the reduction of NOx emissions, fuel burn, and noise from turbine engines in Phase I of the Environmentally Responsible Aviation (ERA) Project (within the Integrated Systems Research Program). ERA subtasks, including those focused on CMC components, were being formulated with the goal of maturing technology from Proof of Concept Validation (Technology Readiness Level 3 (TRL 3)) to System/Subsystem or Prototype Demonstration in a Relevant Environment (TRL 6). LibertyWorks®, a subsidiary of Rolls-Royce Corporation, first studied CMC (ceramic matrix composite) exhaust mixers for potential weight benefits in 2008. Oxide CMC potentially offered weight reduction, higher temperature capability, and the ability to fabricate complex-shapes for increased mixing and noise suppression. In 2010, NASA was pursuing the reduction of NOx emissions, fuel burn, and noise from turbine engines in Phase I of the Environmentally Responsible Aviation (ERA) Project (within the Integrated Systems Research Program). ERA subtasks, including those focused on CMC components, were being formulated with the goal of maturing technology from Proof of Concept Validation (Technology Readiness Level 3 (TRL 3)) to System/Subsystem or Prototype Demonstration in a Relevant Environment (TRL 6). Oxide CMC component at both room and elevated temperatures. A TRL˜5 (Component Validation in a Relevant Environment) was attained and the CMC mixer was cleared for ground testing on a Rolls-Royce AE3007 engine for performance evaluation to achieve TRL 6.

  11. Case Report: A Rare Case Report of Frontal Lobe Syndrome

    Directory of Open Access Journals (Sweden)

    Morteza Nouri- Khajavi

    2003-04-01

    Full Text Available The frontal lobe syndrome is a permanent personality change disorder with characteristic clinical pictures, which followed by frontal lobes damage. Clinical picture include: Affective instability, recurrent aggressive behavior, impaired social judgment, apathy and undifferentiating or suspiciousness and paranoid ideations. According DSM-IV classification frontal lobe syndrome named personality change due to head trauma on Axis I. Herein we report a case of 46 years-old man, who has developed behavioral disturbances following head trauma, about 10 years ago. Main clinical figures in this case are apathy, avolition and, undifferentiating. Clinical pictures are constant during these 10 years. The diagnostic approach has been based on patient’s problems history which, has taken from his family, mental status examination, Neurological examination, Brain imaging and Neuropsychological assessments which related to frontal lobes function. Because of rarity & neglection due to mysterious function of frontal lobes, and also considering that personality change from previous level is prominent figure of this syndrome and also brain imaging findings, which compatible with clinical findings, with this aim, we have reported this case.

  12. Metabolic changes in occipital lobe epilepsy with automatisms

    Directory of Open Access Journals (Sweden)

    Chong H Wong

    2014-07-01

    Full Text Available Purpose: Some studies suggest that the pattern of glucose hypometabolism relates not only to the ictal-onset zone, but also reflects seizure propagation. We investigated metabolic changes in patients with occipital lobe epilepsy (OLE that may reflect propagation of ictal discharge during seizures with automatisms.Methods: Fifteen patients who had undergone epilepsy surgery for intractable OLE and had undergone interictal Fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET between 1994 and 2004 were divided into two groups (with and without automatisms during seizure. Significant regions of hypometabolism were identified by comparing 18F-FDG-PET results from each group with 16 healthy controls by using Statistical Parametric Mapping (SPM 2.Key Findings: Significant hypometabolism was confined largely to the epileptogenic occipital lobe in the patient group without automatisms. In patients with automatisms, glucose hypometabolism extended from the epileptogenic occipital lobe into the ipsilateral temporal lobe.Significance: We identified a distinctive hypometabolic pattern that was specific for OLE patients with automatisms during a seizure. This finding supports the postulate that seizure propagation is a cause of glucose hypometabolism beyond the region of seizure onset.

  13. Medical image of the week: azygous lobe

    Directory of Open Access Journals (Sweden)

    Bhupinder Natt

    2013-12-01

    Full Text Available No abstract available. Article truncated at 150 words. A 59 year old man underwent chest radiography for evaluation of fever and cough. Imaging showed an accessory azygous lobe. An azygos lobe is found in 1% of anatomic specimens and forms when the right posterior cardinal vein, one of the precursors of the azygos vein, fails to migrate over the apex of the lung (1. Instead, the vein penetrates the lung carrying along pleural layers that entrap a portion of the right upper lobe. The vein appears to run within the lung, but is actually surrounded by both parietal and visceral pleura. The azygos fissure therefore consists of four layers of pleura, two parietal layers and two visceral layers, which wrap around the vein giving the appearance of a tadpole. Apart from an interesting incidental radiological finding, it is of limited clinical importance except that its presence should be recognized during thoracoscopic procedures. This patient was found to have …

  14. Severe atrophy of right hepatic lobe simulating right hepatic lobectomy

    International Nuclear Information System (INIS)

    Yeh, C.W.; Strashun, A.; Goldsmith, S.J.

    1981-01-01

    Absence of the right hepatic lobe following blunt abdominal trauma without surgical resection is reported. The usual site of the right hepatic lobe is demonstrated to be occupied by bowel by hepatobiliary imaging

  15. Axial Dispersion Model for Solid Flow in Liquid Suspension in System of Two Mixers in Total Recycle

    Czech Academy of Sciences Publication Activity Database

    Čermáková, Jiřina; Scargiali, F.; Siyakatshana, N.; Kudrna, V.; Brucato, A.; Machoň, V.

    2006-01-01

    Roč. 117, č. 2 (2006), s. 101-107 ISSN 1385-8947 R&D Projects: GA AV ČR(CZ) IAA4072402 Institutional research plan: CEZ:AV0Z40720504 Keywords : residence time distribution * dispersion model * flow mixer Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.594, year: 2006

  16. Feasibility of internal irradiation of a lobe of the lung with P-32 loaded microspheres: I. stability of microspheres in animal studies

    International Nuclear Information System (INIS)

    Llaurado, J.G.; Brewer, L.A. III; Elam, D.A.; Zielinski, F.W.; Hirst, A.E.; Ing, S.J.

    1984-01-01

    Surgical removal, the preferred treatment for lung cancer, is not tolerated by many patients. To test feasibility of treating these cases with high dose isotope irradiation, an occlusion balloon catheter was introduced into a branch of the pulmonary artery in dogs. Ten million (1 g) ion exchange resin microspheres (d. 53-63 μm) labelled with 10-20 mCi P-32 (and 5-10 mCi Tc-99m for imaging) were delivered into the selected lobar artery. After 60 minutes the catheter was withdrawn and a lung scintigraph obtained. Microspheres were prepared by converting cation exchange resin beads to the chromic form, labelling with P-32 phosphate at pH 2 to 4 and stabilizing at pH 9. Quality control testing in boiling physiologic saline confirmed in vitro stability. Since the radiation dose (rad) from total P-32 decay is 733 times the tissue concentration (μCi/g), the injected P-32 distributed in one lobe (ca. 100 g) of canine lung delivers ca. 75,000-150,000 rad. Serial lung scintigraphs were obtained for 8 weeks. Blood level of P-32 was negligible throughout. Following an anesthetic overdoes, dramatic necrosis of the irradiated lobe was observed. Microspheres were visualized histologically in the precapillary beds and never in alveoli or bronchi. Radioactive levels were negligible and no major alterations were discernible in adjacent lung lobes and organs. Thus, large doses of radiation to a selected pulmonary lobe may be delivered without systemic leakage of radioactivity or damage to other organs. This procedure may be useful to destroy inoperable cancer of the lung and other organs

  17. Early seizure propagation from the occipital lobe to medial temporal structures and its surgical implication.

    Science.gov (United States)

    Usui, Naotaka; Mihara, Tadahiro; Baba, Koichi; Matsuda, Kazumi; Tottori, Takayasu; Umeoka, Shuichi; Nakamura, Fumihiro; Terada, Kiyohito; Usui, Keiko; Inoue, Yushi

    2008-12-01

    Intracranial EEG documentation of seizure propagation from the occipital lobe to medial temporal structures is relatively rare. We retrospectively analyzed intracranial EEG recorded with electrodes implanted in the medial temporal lobe in patients who underwent occipital lobe surgery. Four patients with occipital lesions, who underwent intracranial EEG monitoring with intracerebral electrodes implanted in the medial temporal lobe prior to occipital lobe surgery, were studied. Subdural electrodes were placed over the occipital lobe and adjacent areas. Intracerebral electrodes were implanted into bilateral hippocampi and the amygdala in three patients, and in the hippocampus and amygdala ipsilateral to the lesion in one. In light of the intracranial EEG findings, the occipital lobe was resected but the medial temporal lobe was spared in all patients. The follow-up period ranged from six to 16 years, and seizure outcome was Engel Class I in all patients. Sixty six seizures were analyzed. The majority of the seizures originated from the occipital lobe. In complex partial seizures, ictal discharges propagated to the medial temporal lobe. No seizures originating from the temporal lobe were documented. In some seizures, the ictal-onset zone could not be identified. In these seizures, very early propagation to the medial temporal lobe was observed. Interictal spikes were recorded in the medial temporal lobe in all cases. Intracranial EEG revealed very early involvement of the medial temporal lobe in some seizures. Seizure control was achieved without resection of the medial temporal structures.

  18. Transcortical mixed aphasia due to cerebral infarction in left inferior frontal lobe and temporo-parietal lobe

    International Nuclear Information System (INIS)

    Maeshima, S.; Matsumoto, T.; Ueyoshi, A.; Toshiro, H.; Sekiguchi, E.; Okita, R.; Yamaga, H.; Ozaki, F.; Moriwaki, H.; Roger, P.

    2002-01-01

    We present a case of transcortical mixed aphasia caused by a cerebral embolism. A 77-year-old right-handed man was admitted to our hospital with speech disturbance and a right hemianopia. His spontaneous speech was remarkably reduced, and object naming, word fluency, comprehension, reading and writing were all severely disturbed. However, repetition of phonemes and sentences and reading aloud were fully preserved. Although magnetic resonance imaging (MRI) showed cerebral infarcts in the left frontal and parieto-occipital lobe which included the inferior frontal gyrus and angular gyrus, single photon emission CT revealed a wider area of low perfusion over the entire left hemisphere except for part of the left perisylvian language areas. The amytal (Wada) test, which was performed via the left internal carotid artery, revealed that the left hemisphere was dominant for language. Hence, it appears that transcortical mixed aphasia may be caused by the isolation of perisylvian speech areas, even if there is a lesion in the inferior frontal gyrus, due to disconnection from surrounding areas. (orig.)

  19. Transcortical mixed aphasia due to cerebral infarction in left inferior frontal lobe and temporo-parietal lobe

    Energy Technology Data Exchange (ETDEWEB)

    Maeshima, S.; Matsumoto, T.; Ueyoshi, A. [Department of Physical Medicine and Rehabilitation, Wakayama Medical University, Wakayama (Japan); Toshiro, H.; Sekiguchi, E.; Okita, R.; Yamaga, H.; Ozaki, F.; Moriwaki, H. [Department of Neurological Surgery, Hidaka General Hospital, Wakayama (Japan); Roger, P. [School of Communication Sciences and Disorders, University of Sydney, Sydney, NSW (Australia)

    2002-02-01

    We present a case of transcortical mixed aphasia caused by a cerebral embolism. A 77-year-old right-handed man was admitted to our hospital with speech disturbance and a right hemianopia. His spontaneous speech was remarkably reduced, and object naming, word fluency, comprehension, reading and writing were all severely disturbed. However, repetition of phonemes and sentences and reading aloud were fully preserved. Although magnetic resonance imaging (MRI) showed cerebral infarcts in the left frontal and parieto-occipital lobe which included the inferior frontal gyrus and angular gyrus, single photon emission CT revealed a wider area of low perfusion over the entire left hemisphere except for part of the left perisylvian language areas. The amytal (Wada) test, which was performed via the left internal carotid artery, revealed that the left hemisphere was dominant for language. Hence, it appears that transcortical mixed aphasia may be caused by the isolation of perisylvian speech areas, even if there is a lesion in the inferior frontal gyrus, due to disconnection from surrounding areas. (orig.)

  20. Temporal and occipital lobe features in children with hypochondroplasia/FGFR3 gene mutation.

    Science.gov (United States)

    Philpott, Cristina M; Widjaja, Elysa; Raybaud, Charles; Branson, Helen M; Kannu, Peter; Blaser, Susan

    2013-09-01

    Thanatophoric dysplasia (TD) and hypochondroplasia are both caused by FGFR3 (fibroblast growth factor receptor 3) gene mutations. Temporal lobe dysplasia has been well described in thanatophoric dysplasia; however, only a couple of anecdotal cases of temporal lobe dysplasia in hypochondroplasia have been described. To define temporal lobe abnormalities in patients with hypochondroplasia, given that they share the same genetic mutation. We identified brain imaging studies of nine children with hypochondroplasia. The temporal lobes were assessed on CT and MRI for size and configuration of the temporal horn and aberrant sulcation of the inferior surface of the temporal lobe. All children had a triangular-shape temporal horn and deep transverse fissures of the inferior temporal lobe surface. Neuroimaging in our cohort revealed enlarged temporal lobes and oversulcation of the mesial temporal and occipital lobes, with abnormal inferomedial orientation of these redundant gyri. Hippocampal dysplasia was also universal. We confirmed frequent inferomesial temporal and occipital lobe abnormalities in our cohort of children with hypochondroplasia. Murine models with mutant fgfr3 display increased neuroprogenitor proliferation, cortical thickness and surface area in the temporo-occipital cortex. This is thought to result in excessive convolution and likely explains the imaging findings in this patient cohort. (Note that fgfr3 is the same genetic mutation in mice as FGFR3 is in humans.).

  1. Design Mixers to Minimize Effects of Erosion and Corrosion Erosion

    Directory of Open Access Journals (Sweden)

    Julian Fasano

    2012-01-01

    Full Text Available A thorough review of the major parameters that affect solid-liquid slurry wear on impellers and techniques for minimizing wear is presented. These major parameters include (i chemical environment, (ii hardness of solids, (iii density of solids, (iv percent solids, (v shape of solids, (vi fluid regime (turbulent, transitional, or laminar, (vii hardness of the mixer's wetted parts, (viii hydraulic efficiency of the impeller (kinetic energy dissipation rates near the impeller blades, (ix impact velocity, and (x impact frequency. Techniques for minimizing the wear on impellers cover the choice of impeller, size and speed of the impeller, alloy selection, and surface coating or coverings. An example is provided as well as an assessment of the approximate life improvement.

  2. A CLINICORADIOLOGICAL STUDY OF MIDDLE LOBE SYNDROME DUE TO TUBERCULOSIS

    Directory of Open Access Journals (Sweden)

    Saurabh Karmakar

    2016-09-01

    Full Text Available BACKGROUND Although pulmonary tuberculosis is a common disease in India, tuberculosis of right middle lobe is infrequent. Tuberculosis of the right middle lobe leading to chronic collapse is a cause of Right Middle Lobe syndrome. METHODS The patients attended Pulmonary Medicine Outdoor at Era’s Lucknow Medical College, Lucknow from April 2015 to March 2016. The purpose of this study is to describe the clinicoradiological features of patients of middle lobe syndrome due to tuberculosis. All patients presented with cough with or without expectoration, fever, chest pain, haemoptysis and constitutional symptoms like loss of appetite and weight. Chest X-ray PA view revealed ill-defined opacity abutting the right cardiac border. HRCT thorax was done in each case. The diagnosis of tuberculous aetiology was based on (1 History of chronic cough and fever, not responding to antibiotic therapy and constitutional symptoms, (2 A positive tuberculin test using 2 TU of PPD RT 23 and (3 Detection of acid fast bacilli by direct smear or Mycobacterium tuberculosis by polymerase chain reaction in bronchoalveolar lavage. RESULTS Out of 10 patients, 4 (40% were males and 6 (60% were females. The mean ages of the males were 55.8 years and females were 60.8 years and overall mean age was 59 years. Most of the patients were females and belonged to the middle age and old age group. ATT was started in all the patients. CONCLUSIONS Right middle lobe syndrome predominantly affects the older population and the female gender. Although tuberculosis is a common disease in India, Middle Lobe Syndrome is a very rare presentation of the disease. Due to non-specific symptoms and usually normal chest X-ray PA view in Right Middle Lobe Syndrome, we should keep a high index of suspicion to diagnose the condition.

  3. Bicavitary effusion secondary to liver lobe torsion in a dog

    Directory of Open Access Journals (Sweden)

    Khan Z

    2016-04-01

    Full Text Available Zaheda Khan,1 Kathryn Gates,2 Stephen A Simpson,31Emergency and Critical Care, Animal Specialty and Emergency Center, Los Angeles, CA, 2Emergency and Critical Care, Advanced Critical Care, Emergency and Specialty Services, Culver City, CA 3Emergency and Critical Care, Southern California Veterinary Specialty Hospital, Irvine, CA, USA Abstract: We described the diagnosis and successful treatment of pleural and peritoneal effusion secondary to liver lobe torsion in a dog. A 12-year-old female spayed Borzoi dog was referred for heart failure. Emergency room thoracic and abdominal ultrasound showed a large volume of pleural effusion with mild peritoneal effusion and an abdominal mass. Pleural fluid analysis classified the effusion as exudative. A complete ultrasound revealed mild peritoneal effusion and decreased blood flow to the right liver lobe. Other causes of bicavitary effusion were ruled out based on blood work, ultrasound, echocardiogram, and computed tomography. The patient was taken to surgery and diagnosed with caudate liver lobe torsion and had a liver lobectomy. At the 2-week postoperative recheck, the patient was doing well and there was complete resolution of the pleural effusion. Liver lobe torsion is a rare occurrence in dogs and can be difficult to diagnose. Clinical signs are nonspecific for liver lobe torsion and patients may present in respiratory distress with significant pleural fluid accumulation. When assessing patients with pleural and peritoneal effusion, liver lobe torsion should be considered as a differential diagnosis.Keywords: pleural effusion, peritoneal effusion, hepatic torsion

  4. Epilepsy in multiple sclerosis: The role of temporal lobe damage.

    Science.gov (United States)

    Calabrese, M; Castellaro, M; Bertoldo, A; De Luca, A; Pizzini, F B; Ricciardi, G K; Pitteri, M; Zimatore, S; Magliozzi, R; Benedetti, M D; Manganotti, P; Montemezzi, S; Reynolds, R; Gajofatto, A; Monaco, S

    2017-03-01

    Although temporal lobe pathology may explain some of the symptoms of multiple sclerosis (MS), its role in the pathogenesis of seizures has not been clarified yet. To investigate the role of temporal lobe damage in MS patients suffering from epilepsy, by the application of advanced multimodal 3T magnetic resonance imaging (MRI) analysis. A total of 23 relapsing remitting MS patients who had epileptic seizures (RRMS/E) and 23 disease duration matched RRMS patients without any history of seizures were enrolled. Each patient underwent advanced 3T MRI protocol specifically conceived to evaluate grey matter (GM) damage. This includes grey matter lesions (GMLs) identification, evaluation of regional cortical thickness and indices derived from the Neurite Orientation Dispersion and Density Imaging model. Regional analysis revealed that in RRMS/E, the regions most affected by GMLs were the hippocampus (14.2%), the lateral temporal lobe (13.5%), the cingulate (10.0%) and the insula (8.4%). Cortical thinning and alteration of diffusion metrics were observed in several regions of temporal lobe, in insular cortex and in cingulate gyrus of RRMS/E compared to RRMS ( ptemporal lobe, which exceeds what would be expected on the basis of the global GM damage observed.

  5. MRI findings of temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Nakahara, Ichiro; Yin, Dali; Fukami, Masahiro; Kondo, Seiji; Takeuchi, Juji; Kanemoto, Kousuke; Sengoku, Akira; Kawai, Itsuo

    1992-01-01

    MRI findings were analyzed retrospectively in 46 patients with temporal lobe epilepsy in which the side of epileptogenic focus had been confirmed by EEG studies. T 1 - and T 2 -weighted images were obtained by the use of a 1.0 or 1.5 T superconducting-type MRI machine with a coronal scan perpendicular to the axis of the temporal horn of the lateral ventricle. Additional axial and sagittal scans were performed in some cases. The area of the hippocampal body was measured quantitatively using a computerized image-analysis system in 26 cases in which the hippocampus had been visualized with enough contrast on T 1 -weighted coronal images. Abnormal findings were observed in 31/46 (67%) cases. Hippocampal (HC) and temporal lobe (TL) atrophy were observed in 18/46 (39%) and 23/46 (50%) cases respectively, and the side of the atrophy corresponded with the side of the epileptogenic focus, as confirmed by EEG studies, with specificities of 89% and 74% respectively. A quantitative measurement of the area of the hippocampal body showed unilateral hippocampal atrophy more than 10% in 18/25 (69%) cases (10-25%: 10 cases, 25-50%: 7 cases, 50% 2 abnormality was observed in only 4 cases. Structural lesions were observed in 4 cases including an arachnoid cyst, an astrocytoma in amygdala, the Dandy-Walker syndrome, and tuberous sclerosis, using the more efficient imaging qualities than the CT scan. From these observations, it is apparant that superconducting MRI is extremely useful in the diagnosis of the epileptogenic topography of temporal lobe epilepsy. Particularly, hippocampal atrophy was found to correspond with the side of the epileptogenic focus on EEG with a high specificity; its quantitative evaluation could be one of the most important standards in detecting the operative indications for temporal lobe epilepsy. (author)

  6. Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

    Energy Technology Data Exchange (ETDEWEB)

    Ross, James C., E-mail: jross@bwh.harvard.edu [Channing Laboratory, Brigham and Women' s Hospital, Boston, Massachusetts 02215 (United States); Surgical Planning Lab, Brigham and Women' s Hospital, Boston, Massachusetts 02215 (United States); Laboratory of Mathematics in Imaging, Brigham and Women' s Hospital, Boston, Massachusetts 02126 (United States); Kindlmann, Gordon L. [Computer Science Department and Computation Institute, University of Chicago, Chicago, Illinois 60637 (United States); Okajima, Yuka; Hatabu, Hiroto [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts 02215 (United States); Díaz, Alejandro A. [Pulmonary and Critical Care Division, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts 02215 and Department of Pulmonary Diseases, Pontificia Universidad Católica de Chile, Santiago (Chile); Silverman, Edwin K. [Channing Laboratory, Brigham and Women' s Hospital, Boston, Massachusetts 02215 and Pulmonary and Critical Care Division, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts 02215 (United States); Washko, George R. [Pulmonary and Critical Care Division, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts 02215 (United States); Dy, Jennifer [ECE Department, Northeastern University, Boston, Massachusetts 02115 (United States); Estépar, Raúl San José [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts 02215 (United States); Surgical Planning Lab, Brigham and Women' s Hospital, Boston, Massachusetts 02215 (United States); Laboratory of Mathematics in Imaging, Brigham and Women' s Hospital, Boston, Massachusetts 02126 (United States)

    2013-12-15

    Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The

  7. Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

    International Nuclear Information System (INIS)

    Ross, James C.; Kindlmann, Gordon L.; Okajima, Yuka; Hatabu, Hiroto; Díaz, Alejandro A.; Silverman, Edwin K.; Washko, George R.; Dy, Jennifer; Estépar, Raúl San José

    2013-01-01

    Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed

  8. 3D printed microfluidic mixer for point-of-care diagnosis of anemia.

    Science.gov (United States)

    Plevniak, Kimberly; Campbell, Matthew; Mei He

    2016-08-01

    3D printing has been an emerging fabrication tool in prototyping and manufacturing. We demonstrated a 3D microfluidic simulation guided computer design and 3D printer prototyping for quick turnaround development of microfluidic 3D mixers, which allows fast self-mixing of reagents with blood through capillary force. Combined with smartphone, the point-of-care diagnosis of anemia from finger-prick blood has been successfully implemented and showed consistent results with clinical measurements. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.

  9. Socintigraphic evaluation of lateral segment of the left lobe of the liver

    International Nuclear Information System (INIS)

    Oyama, Kazuyuki; Hayashi, Sanshin; Kogure, Takashi; Hirakawa, Ken; Akaike, Akira

    1979-01-01

    Lateral segment of left lobe of the liver is clearly demarcated on sup(99m) Tc-labeled cholescintigram. With analysis of 112 sup(99m) Tc-pyridoxylideneisoleucine scintigrams about lateral border of left lobe, there are some variants in 22 cases (19.7%) in shape in lateral segment of Type 4 left lobe in morphologic classification. Of lateral segment of left lobe, there are classified into five types in the anterior view according to the degeneration; Type 1 is gradually elongated tapered type in 8 cases (36.4%), Type 2 is laterally elongated type as rod shape or island shape in 5 cases (22.7%), Type 3 is lobulated type in 1 case (4.6%), Type 4 is narrowing type in 5 cases (22.7%), Type 5 is indentation type in 3 cases (13.6%). Using colloidal radiopharmaceuticals in liver scintigraphy, lateral segment of left lobe often overlapps with the spleen, which disturb to interpret the abnormality in left lobe of the liver and in the spleen. This analysis depends upon the recent advances in sup(99m) Tc-labeled hepatobiliary radiopharmaceuticals and equipment, and there has never discussed about the shape of lateral segment of left lobe in roentgenologic and scintigraphic evaluations. (author)

  10. The Structural Plasticity of White Matter Networks Following Anterior Temporal Lobe Resection

    Science.gov (United States)

    Yogarajah, Mahinda; Focke, Niels K.; Bonelli, Silvia B.; Thompson, Pamela; Vollmar, Christian; McEvoy, Andrew W.; Alexander, Daniel C.; Symms, Mark R.; Koepp, Matthias J.; Duncan, John S.

    2010-01-01

    Anterior temporal lobe resection is an effective treatment for refractory temporal lobe epilepsy. The structural consequences of such surgery in the white matter, and how these relate to language function after surgery remain unknown. We carried out a longitudinal study with diffusion tensor imaging in 26 left and 20 right temporal lobe epilepsy…

  11. Structural analysis and evaluation of a mixer pump in a double-shell tank at the Hanford Site

    International Nuclear Information System (INIS)

    Rezvani, M.A.; Strehlow, J.P.; Baliga, R.

    1993-01-01

    The double-shell waste tank 241-SY-101 is a 1,000,000 gallon tank used to store radioactive waste at the Hanford Site near Richland, Washington. With time the waste has formed two layers of sludge, a convective and a nonconvective layer. In addition, a crust has formed over the surface of the waste, isolating the convective layer from the vapor space. Ongoing reactions in the waste cause a buildup of hydrogen molecules that become trapped within the nonconvective layer and under the crust. Over time, this hydrogen buildup increases pressure on the crust from beneath. Every 100 to 140 days, the pressure is released when the crust lifts upward in what is called a waste rollover. To prevent the release of a large volume of hydrogen to the vapor space, a mixer pump has been designed to be installed in the tank to circulate the waste and reduce or prevent the hydrogen buildup. The structural analysis and evaluation designed as part of the hydrogen mitigation test process and presented herein addresses the response of the mixer pump and the tank dome resulting from expected operational and design loads. The loads include deadweight, waste rollover, asymmetric thrust, and pump vibration, as well as seismic loads. The seismically induced loads take into consideration both the convective and the impulsive effects of the waste-filled tank. The structural evaluations were performed in accordance with applicable national codes and standards. The qualification of the mixer pump required the design of a unique mounting assembly to transfer the loads from the pump to the surrounding soil without overstressing the structural components such as the dome penetration riser. Also, special consideration was given to minimize the additional stresses in the already stressed concrete tank dome

  12. Method for qualification of cementation processes and its application to a vibration mixer

    International Nuclear Information System (INIS)

    Vicente, R.; Rzyski, B.M.; Suarez, A.A.

    1987-01-01

    In this paper the definition of homogeneneity is discussed and methods to measure the 'degree of heterogeneity' of waste forms are proposed. These measurements are important as aids for mixing process qualification, and as tools in quality assurance procedures and in the development of waste management standards. Homogeneity is a basic quality requirement for waste forms to be accepted in final sites. It do not depend on the matrix immmobilization, rather it is one mean for qualification of the immobilization process. The proposed methods were applied to a vibration assisted mixing process and has proved to an useful mean to judge process improvements. There are many conceivable methods to evaluate homogeneity of waste forms. Some were selected as screening tests aiming at quickly reaching a promising set of process variables. Others were selected to evaluate the degree of excellence of the process in respect to product quality. These envisaged methods were: visual inspection, the use of cement dye as tracer, scanning of radioactive tracers, and measurements of variations of density, water absorption, porosity and mechanical strength across the waste form sample. The process variables were: waste-cement and water-cement ratios, mixer geometry, mixing time and vibration intensity. Some of the apparatus details were change during the experimental work in order to improve product quality. Experimental methods and results statistically analysed and compared with data obtained from samples prepared with a planetary paddle mixer, which were adopted as the homogeneity standard. (Author) [pt

  13. Le lobe pulmonaire azygos: description anatomique d'un cas et ...

    African Journals Online (AJOL)

    Le lobe pulmonaire azygos: description anatomique d'un cas et revue de la ... de la veine azygos qui cravate anormalement le lobe supérieur du poumon droit. ... fortuite chez un homme de 69 ans souffrant d'un cancer broncho-pulmonaire.

  14. Excitatory amino acid transporters EAAT-1 and EAAT-2 in temporal lobe and hippocampus in intractable temporal lobe epilepsy

    DEFF Research Database (Denmark)

    Sarac, Sinan; Afzal, Shoaib; Broholm, Helle

    2009-01-01

    Intractable temporal lobe epilepsy (TLE) is an invalidating disease and many patients are resistant to medical treatment. Increased glutamate concentration has been found in epileptogenic foci and may induce local over-excitation and cytotoxicity; one of the proposed mechanisms involves reduced...... extra-cellular clearance of glutamate by excitatory amino acid transporters (EAAT-1 to EAAT-5). EAAT-1 and EAAT-2 are mainly expressed on astroglial cells for the reuptake of glutamate from the extra-cellular space. We have studied the expression of EAAT-1 and EAAT-2 in the hippocampus and temporal lobe...

  15. Accessory hepatic lobe simulating a left hemidiaphragmatic tumor

    International Nuclear Information System (INIS)

    Kuroiwa, Toshiro; Hirata, Hitoshi; Iwashita, Akinori; Yasumori, Kotaro; Mogami, Hiroshi; Teraoka, Hiroaki

    1984-01-01

    A 72-year-old woman with a 20-year history of neuralgia was confirmed at surgery to have a tumor in the left hemidiaphragmatic region which was connected with the left lobe of the liver. Reassessment of radiological diagnosis after surgery revealed that hepatobiliary scintigraphy and computed tomography using left anterior oblique scanning are useful in differentiating the accessory hepatic lobe of the liver from a tumor and in confirming the diagnosis, respectively. (Namekawa, K.)

  16. Fabrication of a 3D active mixer based on deformable Fe-doped PDMS cones with magnetic actuation

    International Nuclear Information System (INIS)

    Riahi, Mohammadreza; Alizadeh, Elaheh

    2012-01-01

    In this paper an active 3D mixer for lab-on-chip applications is presented. The micrometer size cone shape holes are ablated on a PMMA sheet utilizing a CO 2 laser. The holes are filled with Fe micro-particles and the whole structure is molded with PDMS which cause the Fe micro-particles to be trapped in a PDMS cone structure. These Fe-doped PDMS cones are placed in a PMMA micro-channel structure fabricated by CO 2 laser machining. By applying an external periodic magnetic field, the cones periodically bend in the micro-channel and stir the fluid. The fabrication method and the effect of the magnetic field on the bending of the cones with different aspect ratios is also discussed utilizing computer simulation. Doping the polymers with micro- and nano-metallic particles has been carried out by different research groups before, but according to our knowledge, application of such structures for the fabrication of a 3D active mixer has not been presented before. (paper)

  17. A high linearity current mode second IF CMOS mixer for a DRM/DAB receiver

    International Nuclear Information System (INIS)

    Xu Jian; Zhou Zheng; Wu Yiqiang; Wang Zhigong; Chen Jianping

    2015-01-01

    A passive current switch mixer was designed for the second IF down-conversion in a DRM/DAB receiver. The circuit consists of an input transconductance stage, a passive current switching stage, and a current amplifier stage. The input transconductance stage employs a self-biasing current reusing technique, with a resistor shunt feedback to increase the gain and output impedance. A dynamic bias technique is used in the switching stage to ensure the stability of the overdrive voltage versus the PVT variations. A current shunt feedback is introduced to the conventional low-voltage second-generation fully balanced multi-output current converter (FBMOCCII), which provides very low input impedance and high output impedance. With the circuit working in current mode, the linearity is effectively improved with low supply voltages. Especially, the transimpedance stage can be removed, which simplifies the design considerably. The design is verified with a SMIC 0.18 μm RF CMOS process. The measurement results show that the voltage conversation gain is 1.407 dB, the NF is 16.22 dB, and the IIP3 is 4.5 dBm, respectively. The current consumption is 9.30 mA with a supply voltage of 1.8 V. This exhibits a good compromise among the gain, noise, and linearity for the second IF mixer in DRM/DAB receivers. (paper)

  18. NMR parallel Q-meter with double-balanced-mixer detection for polarized target experiments

    International Nuclear Information System (INIS)

    Boissevain, J.; Tippens, W.B.

    1983-01-01

    A constant-voltage, parallel-tuned nuclear magnetic resonance (NMR) circuit, patterned after a Liverpool design, has been developed for polarized target experiments. Measuring the admittance of the resonance circuit allows advantageous use of double-balanced mixer detection. The resonant circuit is tolerant of stray capacitance between the NMR coil and the target cavity, thus easing target-cell-design constraints. The reference leg of the circuit includes a voltage-controlled attenuator and phase shifter for ease of tuning. The NMR output features a flat background and has good linearity and stability

  19. Representation of thermal information in the antennal lobe of leaf-cutting ants

    Directory of Open Access Journals (Sweden)

    Markus eRuchty

    2010-11-01

    Full Text Available Insects are equipped with various types of antennal sensilla, which house thermosensitive neurons adapted to receive different parameters of the thermal environment for a variety of temperature-guided behaviors. In the leaf-cutting ant Atta vollenweideri, the physiology and the morphology of the thermosensitive sensillum coeloconicum (Sc has been thoroughly investigated. However, the central projections of its receptor neurons are unknown. Here we selectively stained the three neurons found in single Sc and tracked their axons into the brain of Atta vollenweideri workers. Each of the three axons terminates in a single glomerulus of the antennal lobe (Sc-glomeruli. Two of the innervated glomeruli are adjacent to each other and are located laterally, while the third one is clearly separated and located medially in the antennal lobe. Using two-photon Ca2+ imaging of antennal lobe projection neurons, we studied where in the antennal lobe thermal information is represented. In the 11 investigated antennal lobes, we found up to 10 different glomeruli in a single specimen responding to temperature stimulation. Both, warm- and cold-sensitive glomeruli could be identified. The thermosensitive glomeruli were mainly located in the medial part of the antennal lobe. Based on the general representation of thermal information in the antennal lobe and functional data on the Sc-glomeruli we conclude that temperature stimuli received by Sc are processed in the medial of the three target glomeruli. The present study reveals an important role of the antennal lobe in temperature processing and links a specific thermosensitive neuron to its central target glomerulus.

  20. Temperature-controlled continuous production of all-trans retinoic acid-loaded solid lipid nanoparticles using static mixers

    Science.gov (United States)

    Shao, Wenyao; Yan, Mengwen; Chen, Tingting; Chen, Yuqing; Xiao, Zongyuan

    2017-04-01

    This work aims to develop a temperature-controlled continuous solvent emulsification-diffusion process to synthesize all-trans retinoic acid (ATRA)-loaded solid lipid nanoparticles (SLNs) using static mixers. ATRA-loaded SLNs of around 200 nm were obtained when the flow rates of the organic and aqueous phases were 50 ml min-1 and 500 ml min-1, respectively. It was found that the lipid concentration played a dominant role in the size of the obtained SLNs, and higher drug concentration resulted in relatively low entrapment efficiency. The encapsulation of ATRA in the SLNs was effective in improving its stability according to the photo-degradation test. The in vitro release of SLN was slow without an initial burst. This study demonstrates that the solvent emulsification-diffusion technique with static mixing is an effective method of producing SLNs, and could easily be scaled up for industrial applications. Highlights Higher lipid concentration leads to larger SLNs. SLN transformation occurs due to Ostwald ripening. The ATRA-loaded SLNs around 200 nm were successfully produced with static mixers. ATRA-loaded SLNs show better stability towards sunlight. ATRA in SLNs exhibited a relatively slow release rate without a significant initial burst.

  1. Seizure semiology identifies patients with bilateral temporal lobe epilepsy.

    Science.gov (United States)

    Loesch, Anna Mira; Feddersen, Berend; Tezer, F Irsel; Hartl, Elisabeth; Rémi, Jan; Vollmar, Christian; Noachtar, Soheyl

    2015-01-01

    Laterality in temporal lobe epilepsy is usually defined by EEG and imaging results. We investigated whether the analysis of seizure semiology including lateralizing seizure phenomena identifies bilateral independent temporal lobe seizure onset. We investigated the seizure semiology in 17 patients in whom invasive EEG-video-monitoring documented bilateral temporal seizure onset. The results were compared to 20 left and 20 right consecutive temporal lobe epilepsy (TLE) patients who were seizure free after anterior temporal lobe resection. The seizure semiology was analyzed using the semiological seizure classification with particular emphasis on the sequence of seizure phenomena over time and lateralizing seizure phenomena. Statistical analysis included chi-square test or Fisher's exact test. Bitemporal lobe epilepsy patients had more frequently different seizure semiology (100% vs. 40%; p<0.001) and significantly more often lateralizing seizure phenomena pointing to bilateral seizure onset compared to patients with unilateral TLE (67% vs. 11%; p<0.001). The sensitivity of identical vs. different seizure semiology for the identification of bilateral TLE was high (100%) with a specificity of 60%. Lateralizing seizure phenomena had a low sensitivity (59%) but a high specificity (89%). The combination of lateralizing seizure phenomena and different seizure semiology showed a high specificity (94%) but a low sensitivity (59%). The analysis of seizure semiology including lateralizing seizure phenomena adds important clinical information to identify patients with bilateral TLE. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Physiological Modeling of Responses to Upper vs Lower Lobe Lung Volume Reduction in Homogeneous Emphysema

    Directory of Open Access Journals (Sweden)

    Arschang eValipour

    2012-10-01

    Full Text Available Rationale: In clinical trials, homogeneous emphysema patients have responded well to upper lobe volume reduction but not lower lobe volume reduction. Materials/Methods: To understand the physiological basis for this observation, a computer model was developed to simulate the effects of upper and lower lobe lung volume reduction on RV/TLC and lung recoil in homogeneous emphysema.Results: Patients with homogeneous emphysema received either upper or lower lobe volume reduction therapy based on findings of radionucleotide scintigraphy scanning. CT analysis of lobar volumes showed that patients undergoing upper (n=18; -265 mL/site and lower lobe treatment (n=11; -217 mL/site experienced similar reductions in lung volume. However, only upper lobe treatment improved FEV1 (+11.1±14.7% vs -4.4±15.8% and RV/TLC (-5.4± 8.1% vs -2.4±8.6%. Model simulations provided an unexpected explanation for this response. Increases in transpulmonary pressure subsequent to volume reduction increased RV/TLC in upper lobe alveoli, while caudal shifts in airway closure decreased RV/TLC in lower lobe alveoli. Upper lobe treatment, which eliminates apical alveoli with high RV/TLC values, lowers the average RV/TLC of the lung. Conversely, lower lobe treatment, which eliminates caudal alveoli with low RV/TLC values, has less effect. Conclusions: Lower lobe treatment in homogeneous emphysema is uniformly less effective than upper lobe treatment.

  3. Astrocyte uncoupling as a cause of human temporal lobe epilepsy.

    Science.gov (United States)

    Bedner, Peter; Dupper, Alexander; Hüttmann, Kerstin; Müller, Julia; Herde, Michel K; Dublin, Pavel; Deshpande, Tushar; Schramm, Johannes; Häussler, Ute; Haas, Carola A; Henneberger, Christian; Theis, Martin; Steinhäuser, Christian

    2015-05-01

    Glial cells are now recognized as active communication partners in the central nervous system, and this new perspective has rekindled the question of their role in pathology. In the present study we analysed functional properties of astrocytes in hippocampal specimens from patients with mesial temporal lobe epilepsy without (n = 44) and with sclerosis (n = 75) combining patch clamp recording, K(+) concentration analysis, electroencephalography/video-monitoring, and fate mapping analysis. We found that the hippocampus of patients with mesial temporal lobe epilepsy with sclerosis is completely devoid of bona fide astrocytes and gap junction coupling, whereas coupled astrocytes were abundantly present in non-sclerotic specimens. To decide whether these glial changes represent cause or effect of mesial temporal lobe epilepsy with sclerosis, we developed a mouse model that reproduced key features of human mesial temporal lobe epilepsy with sclerosis. In this model, uncoupling impaired K(+) buffering and temporally preceded apoptotic neuronal death and the generation of spontaneous seizures. Uncoupling was induced through intraperitoneal injection of lipopolysaccharide, prevented in Toll-like receptor4 knockout mice and reproduced in situ through acute cytokine or lipopolysaccharide incubation. Fate mapping confirmed that in the course of mesial temporal lobe epilepsy with sclerosis, astrocytes acquire an atypical functional phenotype and lose coupling. These data suggest that astrocyte dysfunction might be a prime cause of mesial temporal lobe epilepsy with sclerosis and identify novel targets for anti-epileptogenic therapeutic intervention. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Determination of the interfacial area of a continuous integrated mixer/separator (CINC) using a chemical reaction method

    NARCIS (Netherlands)

    Schuur, B.; Jansma, W. J.; Winkelman, J. G. M.; Heeres, H. J.

    The effect of the liquid flow rates (18-100 mL/min) and rotor frequency (30-60 Hz) on the interfacial area of a liquid-liquid system in a CINC-V02 continuous integrated mixer/separator have been studied using a chemical reaction method. Topical specific interfacial areas were in the range of 3.2 x

  5. Temporal order processing of syllables in the left parietal lobe.

    Science.gov (United States)

    Moser, Dana; Baker, Julie M; Sanchez, Carmen E; Rorden, Chris; Fridriksson, Julius

    2009-10-07

    Speech processing requires the temporal parsing of syllable order. Individuals suffering from posterior left hemisphere brain injury often exhibit temporal processing deficits as well as language deficits. Although the right posterior inferior parietal lobe has been implicated in temporal order judgments (TOJs) of visual information, there is limited evidence to support the role of the left inferior parietal lobe (IPL) in processing syllable order. The purpose of this study was to examine whether the left inferior parietal lobe is recruited during temporal order judgments of speech stimuli. Functional magnetic resonance imaging data were collected on 14 normal participants while they completed the following forced-choice tasks: (1) syllable order of multisyllabic pseudowords, (2) syllable identification of single syllables, and (3) gender identification of both multisyllabic and monosyllabic speech stimuli. Results revealed increased neural recruitment in the left inferior parietal lobe when participants made judgments about syllable order compared with both syllable identification and gender identification. These findings suggest that the left inferior parietal lobe plays an important role in processing syllable order and support the hypothesized role of this region as an interface between auditory speech and the articulatory code. Furthermore, a breakdown in this interface may explain some components of the speech deficits observed after posterior damage to the left hemisphere.

  6. Usefulness of PET in non-lesional temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Bertuluchi, M.; Arganaraz, R.; Buznick, J.; Pomata, H.

    2011-01-01

    Objective. To evaluate the usefulness of PET in patients with refractory non-lesional temporal lobe epilepsy. Material and methods. We present three patients with features of temporal lobe epilepsy refractory to medication, where high definition MRI was normal. Results. These patients had PET hypometabolism in the temporal areas related to clinical and neurophysiological findings. Two of these patients were implanted with subdural grids to confirm the diagnosis and the third was operated directly based on the findings of PET. Encourage the presentation of the importance in recent years is acquiring the PET. Conclusion. In those patients in clinical neurophysiology and epilepsy with suspected temporal lobe, but in the MRI images show no structural lesions, PET can play an important role defining the diagnosis. (authors)

  7. MR imaging of temporal lobe meningoencephalocele

    International Nuclear Information System (INIS)

    Tampieri, D.; Leblanc, R.; Melangon, D.; del-Carpio-O'Donovan, R.; Ethier, R.

    1991-01-01

    Basal meningoencephaloceles represent a rare entity, and they may be associated with a variety of midline cerebral abnormalities. The classification of basal meningoencephaloceles is related to their anatomic location. This paper reports experience in 3 patients, 2 who have temporal lobe epilepsy and a bone defect in the region of the foramen rotondum. In these 2 patients the encephalocele and its covering were protruding into the pterygopalatine fossa without any orbital involvement. The third patient presented with cerebrospinal fluid rhinorrhea caused by a transsphenoidal meningoencephalocele. MR imaging is the examination of choice for detecting these lesions since it allows for the visualization of the encephalocele and its meningeal covering as well as the bone defect and associated lesions in the temporal lobes

  8. Functional connectivity evidence of cortico-cortico inhibition in temporal lobe epilepsy.

    Science.gov (United States)

    Tracy, Joseph I; Osipowicz, Karol; Spechler, Philip; Sharan, Ashwini; Skidmore, Christopher; Doucet, Gaelle; Sperling, Michael R

    2014-01-01

    Epileptic seizures can initiate a neural circuit and lead to aberrant neural communication with brain areas outside the epileptogenic region. We focus on interictal activity in focal temporal lobe epilepsy and evaluate functional connectivity (FC) differences that emerge as function of bilateral versus strictly unilateral epileptiform activity. We assess the strength of FC at rest between the ictal and non-ictal temporal lobes, in addition to whole brain connectivity with the ictal temporal lobe. Results revealed strong connectivity between the temporal lobes for both patient groups, but this did not vary as a function of unilateral versus bilateral interictal status. Both the left and right unilateral temporal lobe groups showed significant anti-correlated activity in regions outside the epileptogenic temporal lobe, primarily involving the contralateral (non-ictal/non-pathologic) hemisphere, with precuneus involvement prominent. The bilateral groups did not show this contralateral anti-correlated activity. This anti-correlated connectivity may represent a form of protective and adaptive inhibition, helping to constrain epileptiform activity to the pathologic temporal lobe. The absence of this activity in the bilateral groups may be indicative of flawed inhibitory mechanisms, helping to explain their more widespread epileptiform activity. Our data suggest that the location and build up of epilepsy networks in the brain are not truly random, and are not limited to the formation of strictly epileptogenic networks. Functional networks may develop to take advantage of the regulatory function of structures such as the precuneus to instantiate an anti-correlated network, generating protective cortico-cortico inhibition for the purpose of limiting seizure spread or epileptogenesis. Copyright © 2012 Wiley Periodicals, Inc.

  9. A circuit-level analysis of third order intermodulation mechanisms in CMOS mixers using time-invariant power and Volterra series

    NARCIS (Netherlands)

    Sakian, P.; Mahmoudi, R.; Roermund, van A.H.M.

    2011-01-01

    An in-depth analysis is performed on the third-order intermodulation distortions (IMD3) in the switching pair of active CMOS mixers. The nonlinear time-varying switching pair is described by a hypothetical circuit composed of a nonlinear time-invariant circuit cascaded with a linear time-varying

  10. Surgical anatomy of the pyramidal lobe and its significance in ...

    African Journals Online (AJOL)

    In diffuse thyroid diseases, the lobes were always pathologically involved and significantly longer. Conclusion. Since the pyramidal lobe is a normal component of the thyroid gland, of varying position and size, with pathological changes in benign and malignant diseases, it should always be examined during thyroid surgery ...

  11. Thalamotemporal impairment in temporal lobe epilepsy: a combined MRI analysis of structure, integrity, and connectivity.

    Science.gov (United States)

    Keller, Simon S; O'Muircheartaigh, Jonathan; Traynor, Catherine; Towgood, Karren; Barker, Gareth J; Richardson, Mark P

    2014-02-01

    Thalamic abnormality in temporal lobe epilepsy (TLE) is well known from imaging studies, but evidence is lacking regarding connectivity profiles of the thalamus and their involvement in the disease process. We used a novel multisequence magnetic resonance imaging (MRI) protocol to elucidate the relationship between mesial temporal and thalamic pathology in TLE. For 23 patients with TLE and 23 healthy controls, we performed T1 -weighted (for analysis of tissue structure), diffusion tensor imaging (tissue connectivity), and T1 and T2 relaxation (tissue integrity) MRI across the whole brain. We used connectivity-based segmentation to determine connectivity patterns of thalamus to ipsilateral cortical regions (occipital, parietal, prefrontal, postcentral, precentral, and temporal). We subsequently determined volumes, mean tractography streamlines, and mean T1 and T2 relaxometry values for each thalamic segment preferentially connecting to a given cortical region, and of the hippocampus and entorhinal cortex. As expected, patients had significant volume reduction and increased T2 relaxation time in ipsilateral hippocampus and entorhinal cortex. There was bilateral volume loss, mean streamline reduction, and T2 increase of the thalamic segment preferentially connected to temporal lobe, corresponding to anterior, dorsomedial, and pulvinar thalamic regions, with no evidence of significant change in any other thalamic segments. Left and right thalamotemporal segment volume and T2 were significantly correlated with volume and T2 of ipsilateral (epileptogenic), but not contralateral (nonepileptogenic), mesial temporal structures. These convergent and robust data indicate that thalamic abnormality in TLE is restricted to the area of the thalamus that is preferentially connected to the epileptogenic temporal lobe. The degree of thalamic pathology is related to the extent of mesial temporal lobe damage in TLE. © 2014 The Authors. Epilepsia published by Wiley Periodicals, Inc

  12. Altered cortical anatomical networks in temporal lobe epilepsy

    Science.gov (United States)

    Lv, Bin; He, Huiguang; Lu, Jingjing; Li, Wenjing; Dai, Dai; Li, Meng; Jin, Zhengyu

    2011-03-01

    Temporal lobe epilepsy (TLE) is one of the most common epilepsy syndromes with focal seizures generated in the left or right temporal lobes. With the magnetic resonance imaging (MRI), many evidences have demonstrated that the abnormalities in hippocampal volume and the distributed atrophies in cortical cortex. However, few studies have investigated if TLE patients have the alternation in the structural networks. In the present study, we used the cortical thickness to establish the morphological connectivity networks, and investigated the network properties using the graph theoretical methods. We found that all the morphological networks exhibited the small-world efficiency in left TLE, right TLE and normal groups. And the betweenness centrality analysis revealed that there were statistical inter-group differences in the right uncus region. Since the right uncus located at the right temporal lobe, these preliminary evidences may suggest that there are topological alternations of the cortical anatomical networks in TLE, especially for the right TLE.

  13. The role of histopathologic subtype in the setting of hippocampal sclerosis-associated mesial temporal lobe epilepsy.

    Science.gov (United States)

    Gales, Jordan M; Jehi, Lara; Nowacki, Amy; Prayson, Richard A

    2017-05-01

    Hippocampal sclerosis (HS) and focal cortical dysplasia (FCD) are among the most common neuropathological findings in those undergoing surgery for refractory mesial temporal lobe epilepsy. Existing data regarding differences among the most recent International League Against Epilepsy (ILAE) HS subtypes remain limited. This study sought to characterize the roles of HS subtype and coexistent FCD. Epilepsy surgery pathologic specimens in 307 cases of temporal lobe epilepsy with HS were reviewed (mean age±SD, 37±15years; 56% women). HS and coexistent FCD were classified according to ILAE guidelines. Medical records were reviewed for data on seizure recurrence and seizure burden (clinical follow-up mean duration ± SD, 5±4years). Cases of typical HS (ILAE type I) predominated (ILAE type Ia: 41%, Ib: 47%, II: 11%, and III: 0.7%]. The HS subtypes shared similar demographic and etiologic characteristics, as well as associated pathology and postoperative seizure outcomes. Individuals with type Ib HS were more likely to remain seizure free at long-term follow-up when compared with other subtypes, and they had a later age of seizure onset. Two hundred forty-three cases (79%) demonstrated FCD within the adjacent temporal lobe. Its presence was associated with a significantly decreased risk of seizure recurrence (P=.02). When present, FCD was predominantly type I (98%). HS subtype does not appear to affect epilepsy surgery outcomes despite some clinical differences between the subgroups. FCD is often observed in association with HS in mesial temporal lobe epilepsy; the finding of FCD was associated with better postoperative outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Enhancing the efficiency of a three-lobe roots blower by means of by-passing gas to the working cavity through an ejector adaptor

    Science.gov (United States)

    Vizgalov, S. V.; Volkov, M. V.; Chekushkin, G. N.; Khisameev, I. G.

    2017-08-01

    A positive displacement Roots blower with two- or three-lobe straight-tooth or twisted rotors demonstrates high performance with small specific dimensions and is used to boost internal combustion engines, aerate tanks of treatment facilities, is employed in air and gas transport systems in the food, petrochemical and metallurgical industry. It is common knowledge that several solutions have been implemented in Roots blower designs with straight-tooth with three-lobe or more-lobes rotors. It is more practical to bypass a portion of the compressed gas to the working cavity of the blower through an ejector. The purpose of developing a mathematical model for a blower working in conjunction with an ejector adapter and the further research is to determine the efficiency of this scheme un-der different discharge pressure conditions and different ejector active flow temperatures (the gas cooling effect before the nozzle).

  15. Design of the ME-I powder mixer. Report of the design and construction of the powder mixer, according to the safety requisites of the pellets fabrication process; Diseno de mezclador de polvo ME-I. Reporte del diseno y construccion del mezclador de polvos, de acuerdo a los requisitos de seguridad del proceso de fabricacion de pastillas

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-03-15

    In order to fulfill the requirements of preparation of powder of UO{sub 2}; according to procedure P-M-PP-01, rev. 0, for the process of production of pellets, it was designed and manufactured a powders mixer to incorporate the lubricant one (zinc stearate) to the powder of UO{sub 2}. This equipment allows to mix the powder of UO{sub 2} evenly with the one zinc stearate, without forming considerable quantities of fine of UO{sub 2}, besides a sure control for the operators of the process and an easy access to the mixer to inspect the mixture. (Author)

  16. Observational demonstration of a high image rejection SIS mixer receiver using a new waveguide filter at 230 GHz

    Science.gov (United States)

    Hasegawa, Yutaka; Asayama, Shinichiro; Harada, Ryohei; Tokuda, Kazuki; Kimura, Kimihiro; Ogawa, Hideo; Onishi, Toshikazu

    2017-12-01

    A new sideband separation method was developed for use in millimeter-/submillimeter-band radio receivers using a novel waveguide frequency separation filter (FSF), which consists of two branch line hybrid couplers and two waveguide high-pass filters. The FSF was designed to allow the radio frequency (RF) signal to pass through to an output port when the frequency is higher than a certain value (225 GHz), and to reflect the RF signal back to another output port when the frequency is lower. The FSF is connected to two double sideband superconductor-insulator-superconductor (SIS) mixers, and an image rejection ratio (IRR) is determined by the FSF characteristics. With this new sideband separation method, we can achieve good and stable IRR without the balancing two SIS mixers such as is necessary for conventional sideband-separating SIS mixers. To demonstrate the applicability of this method, we designed and developed an FSF for simultaneous observations of the J = 2-1 rotational transition lines of three CO isotopes (12CO, 13CO, and C18O): the 12CO line is in the upper sideband and the others are in the lower sideband with an intermediate-frequency range of 4-8 GHz at the radio frequency of 220/230 GHz. This FSF was then installed in the receiver system of the 1.85 m radio telescope of Osaka Prefecture University, and was used during the 2014 observation season. The observation results indicate that the IRR of the proposed receiver is 25 dB or higher for the 12CO line, and no significant fluctuation larger than 1 dB in the IRR was observed throughout the season. These results demonstrate the practical utility of the FSF receiver for observations like extensive molecular cloud surveys in specified lines with a fixed frequency setting.

  17. Giant lipoma arising from deep lobe of the parotid gland

    Directory of Open Access Journals (Sweden)

    Hsu Ying-Che

    2006-06-01

    Full Text Available Abstract Background Lipomas are common benign soft tissue neoplasms but they are found very rarely in the deep lobe of parotid gland. Surgical intervention in these tumors is challenging because of the proximity of the facial nerve, and thus knowledge of the anatomy and meticulous surgical technique are essential. Case presentation A 71-year-old female presented with a large asymptomatic mass, which had occupied the left facial area for over the past fifteen years, and she requested surgical excision for a cosmetically better facial appearance. The computed tomography (CT scan showed a well-defined giant lipoma arising from the left deep parotid gland. The lipoma was successfully enucleated after full exposure and mobilization of the overlying facial nerve branches. The surgical specimen measured 9 × 6 cm in size, and histopathology revealed fibrolipoma. The patient experienced an uneventful recovery, with a satisfying facial contour and intact facial nerve function. Conclusion Giant lipomas involving the deep parotid lobe are extremely rare. The high-resolution CT scan provides an accurate and cost-effective preoperative investigative method. Surgical management of deep lobe lipoma should be performed by experienced surgeons due to the need for meticulous dissection of the facial nerve branches. Superficial parotidectomy before deep lobe lipoma removal may be unnecessary in selected cases because preservation of the superficial lobe may contribute to a better aesthetic and functional result.

  18. Automatic lung lobe segmentation of COPD patients using iterative B-spline fitting

    Science.gov (United States)

    Shamonin, D. P.; Staring, M.; Bakker, M. E.; Xiao, C.; Stolk, J.; Reiber, J. H. C.; Stoel, B. C.

    2012-02-01

    We present an automatic lung lobe segmentation algorithm for COPD patients. The method enhances fissures, removes unlikely fissure candidates, after which a B-spline is fitted iteratively through the remaining candidate objects. The iterative fitting approach circumvents the need to classify each object as being part of the fissure or being noise, and allows the fissure to be detected in multiple disconnected parts. This property is beneficial for good performance in patient data, containing incomplete and disease-affected fissures. The proposed algorithm is tested on 22 COPD patients, resulting in accurate lobe-based densitometry, and a median overlap of the fissure (defined 3 voxels wide) with an expert ground truth of 0.65, 0.54 and 0.44 for the three main fissures. This compares to complete lobe overlaps of 0.99, 0.98, 0.98, 0.97 and 0.87 for the five main lobes, showing promise for lobe segmentation on data of patients with moderate to severe COPD.

  19. A study using computerized tomography in the clinical practice of temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Yamamoto, Kunimitsu

    1982-01-01

    The author has studied about analysis of clinical data and CT findings examined conventional method for 50 cases of temporal lobe epilepsy and how to assess the foci of temporal lobe by CT. According to the examination of conventional neuroradiologic technique and routine work of CT for temporal lobe epilepsy, an extreme space occuping lesions were detected and marked cerebral atrophy, low density area in temporal lobe were found out, but, most of them were not able to detect foci of the temporal lobe and yet, the study of CT number based on the print out data did not give any precise informations about epileptogenic lesions of temporal lobe epilepsy. The method of reversed axial section CT was designed to photograph inferior horn of lateral ventricles with the purpose to delineate the hippocampus and amygdata, and precise pictures from autopsy brain and clinical cases were obtained by that method about scanning angle of reversed axial section CT, various angles are made an experiment on scanning, such as reversed 15 0 , 20 0 , 25 0 , 30 0 , 35 0 . Among them, it is proved that the reversed angle of almost 25 0 is most suitable to delineate mesial temporal structure, so as to say, foci of the temporal lobe. (J.P.N.)

  20. Development of continuous mixer originated from an idea of udon noodle kneading; Udonneri no haso ni yoru renzokuneri mikisa no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Matabe; Yamada, Ichiu [Maeda Corp., Tokyo (Japan)

    1999-06-10

    The titled idea was applied to solve a difficult mixing problem of concrete of high fine powder content. In mixing of powdery concrete, and there are disadvantages that long time is required and uniform mixing of water with material is difficult. To solve these disadvantages, a udon noodle kneading system in which an action of folding and extending was repeated to uniformly disperse material was adopted. This is a utilization case of theory of n powers of 2, the material is uniformly dispersed becoming 1,024 layers in 10 times, one million layers in 20 time, 1 billion layers in 30 times. A new model mixer M{center_dot}Y BOX was developed and compared with the conventional system. While an experiment is under way, this mixer seems to be applicable to food industry, pharmaceutical industry, pottery,chemical industry. (NEDO)

  1. Hilar somatostatin interneuron loss reduces dentate gyrus inhibition in a mouse model of temporal lobe epilepsy.

    Science.gov (United States)

    Hofmann, Gabrielle; Balgooyen, Laura; Mattis, Joanna; Deisseroth, Karl; Buckmaster, Paul S

    2016-06-01

    In patients with temporal lobe epilepsy, seizures usually start in the hippocampus, and dentate granule cells are hyperexcitable. Somatostatin interneurons are a major subpopulation of inhibitory neurons in the dentate gyrus, and many are lost in patients and animal models. However, surviving somatostatin interneurons sprout axon collaterals and form new synapses, so the net effect on granule cell inhibition remains unclear. The present study uses optogenetics to activate hilar somatostatin interneurons and measure the inhibitory effect on dentate gyrus perforant path-evoked local field potential responses in a mouse model of temporal lobe epilepsy. In controls, light activation of hilar somatostatin interneurons inhibited evoked responses up to 40%. Epileptic pilocarpine-treated mice exhibited loss of hilar somatostatin interneurons and less light-induced inhibition of evoked responses. These findings suggest that severe epilepsy-related loss of hilar somatostatin interneurons can overwhelm the surviving interneurons' capacity to compensate by sprouting axon collaterals. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  2. Changes in frontal lobe function before and after surgery in patients with unruptured intracranial aneurysm

    International Nuclear Information System (INIS)

    Ozaki, Saya; Kumon, Yoshiaki; Igase, Keiji; Watanabe, Hideaki; Ohnishi, Takanori

    2008-01-01

    We evaluated neuropsychological function in 18 patients with unruptured cerebral aneurysm who showed good postoperative outcomes. We paid particular attention to frontal lobe function. We also investigated relationships between cerebral blood flow (CBF) and frontal lobe function. Patients were examined using digit span, word fluency (WF), Stroop and trail-making tests to clarify frontal lobe function before and 1-2 months after surgery. We also used the mini-mental state examination (MMSE), Raven's colored progressive matrices (RCPM) and revised Wechsler adult intelligence scale (WAIS-R) to examine cognitive function. CBF was measured using 133 Xe-single photon emission computed tomography (SPECT) before and 1-2 months after surgery. Tests revealed that the patients' postoperative neuropsychological status was improved compared to the preoperative status for MMSE, RCPM and WAIS-R. Among the tests of frontal lobe function, WF results had deteriorated significantly after surgery. Resting CBF in the frontal lobe was significantly decreased. Regional CBF in the frontal lobe was decreased significantly in comparison with values in the parietal and temporal lobes in patients showing deterioration of WF. Deterioration of WF correlated with CBF changes in the frontal lobe. These results suggest that surgery for unruptured cerebral aneurysm exerts detrimental effects on frontal lobe function that may be related to CBF changes. (author)

  3. Phase locking of 2.324 and 2.959 terahertz quantum cascade lasers using a Schottky diode harmonic mixer.

    Science.gov (United States)

    Danylov, Andriy; Erickson, Neal; Light, Alexander; Waldman, Jerry

    2015-11-01

    The 23rd and 31st harmonics of a microwave signal generated in a novel THz balanced Schottky diode mixer were used as a frequency stable reference source to phase lock solid-nitrogen-cooled 2.324 and 2.959 THz quantum cascade lasers. Hertz-level frequency stability was achieved, which was maintained for several hours.

  4. Auditory temporal processing in patients with temporal lobe epilepsy.

    Science.gov (United States)

    Lavasani, Azam Navaei; Mohammadkhani, Ghassem; Motamedi, Mahmoud; Karimi, Leyla Jalilvand; Jalaei, Shohreh; Shojaei, Fereshteh Sadat; Danesh, Ali; Azimi, Hadi

    2016-07-01

    Auditory temporal processing is the main feature of speech processing ability. Patients with temporal lobe epilepsy, despite their normal hearing sensitivity, may present speech recognition disorders. The present study was carried out to evaluate the auditory temporal processing in patients with unilateral TLE. The present study was carried out on 25 patients with epilepsy: 11 patients with right temporal lobe epilepsy and 14 with left temporal lobe epilepsy with a mean age of 31.1years and 18 control participants with a mean age of 29.4years. The two experimental and control groups were evaluated via gap-in-noise and duration pattern sequence tests. One-way ANOVA was run to analyze the data. The mean of the threshold of the GIN test in the control group was observed to be better than that in participants with LTLE and RTLE. Also, it was observed that the percentage of correct responses on the DPS test in the control group and in participants with RTLE was better than that in participants with LTLE. Patients with TLE have difficulties in temporal processing. Difficulties are more significant in patients with LTLE, likely because the left temporal lobe is specialized for the processing of temporal information. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The neurobiology of cognitive disorders in temporal lobe epilepsy

    Science.gov (United States)

    Bell, Brian; Lin, Jack J.; Seidenberg, Michael; Hermann, Bruce

    2013-01-01

    Cognitive impairment and especially memory disruption is a major complicating feature of the epilepsies. In this review we begin with a focus on the problem of memory impairment in temporal lobe epilepsy. We start with a brief overview of the early development of knowledge regarding the anatomic substrates of memory disorder in temporal lobe epilepsy, followed by discussion of the refinement of that knowledge over time as informed by the outcomes of epilepsy surgery (anterior temporal lobectomy) and the clinical efforts to predict those patients at greatest risk of adverse cognitive outcomes following epilepsy surgery. These efforts also yielded new theoretical insights regarding the function of the human hippocampus and a few examples of these insights are touched on briefly. Finally, the vastly changing view of temporal lobe epilepsy is examined including findings demonstrating that anatomic abnormalities extend far outside the temporal lobe, cognitive impairments extend beyond memory function, with linkage of these distributed cognitive and anatomic abnormalities pointing to a new understanding of the anatomic architecture of cognitive impairment in epilepsy. Challenges remain in understanding the origin of these cognitive and anatomic abnormalities, their progression over time, and most importantly, how to intervene to protect cognitive and brain health in epilepsy. PMID:21304484

  6. DUAL POLARIZATION ANTENNA ARRAY WITH VERY LOW CROSS POLARIZATION AND LOW SIDE LOBES

    DEFF Research Database (Denmark)

    1997-01-01

    The present invention relates to an antenna array adapted to radiate or receive electromagnetic waves of one or two polarizations with very low cross polarization and low side lobes. An antenna array comprising many antenna elements, e.g. more than ten antenna elements, is provided in which...... formation of grating lobes are inhibited in selected directions of the radiation and cross polarization within the main lobe is suppressed at least 30 dB below the main lobe peak value. According to a preferred embodiment of the invention, the antenna elements of the antenna array comprise probe-fed patches...

  7. Interphase transfer kinetics of uranium using the drop method, Lewis cell, and Kenics mixer

    International Nuclear Information System (INIS)

    Horner, D.E.; Mailen, J.C.; Thiel, S.W.; Scott, T.C.; Yates, R.G.

    1979-05-01

    The rate constants for the interphase transfer of uranium between 3.5 M HNO 3 and tributyl phosphate (TBP) - normal hydrocarbon diluent solutions have been measured using the single drop method, Lewis cell method, and a Kenics mixer - centrifugal separator. Rate constants obtained by all methods were the same within experimental error. The variables studied that affect the rate constants include the TBP concentration, the acidity and total neutral nitrate concentrations of the aqueous phase, and temperature. Results of these tests indicate that the rate controlling mechanism is chemical reaction at the interface

  8. Temporal lobe epilepsy and focal cortical dysplasia in children: A tip to find the abnormality.

    Science.gov (United States)

    Bartolini, Luca; Whitehead, Matthew T; Ho, Cheng-Ying; Sepeta, Leigh N; Oluigbo, Chima O; Havens, Kathryn; Freilich, Emily R; Schreiber, John M; Gaillard, William D

    2017-01-01

    To demonstrate an association between magnetic resonance imaging (MRI) findings and pathologic characteristics in children who had surgery for medically refractory epilepsy due to focal cortical dysplasia (FCD). We retrospectively studied 110 children who had epilepsy surgery. Twenty-seven patients with FCD were included. Thirteen had temporal lobe epilepsy (TLE) and 14 had extra-temporal lobe epilepsy (ETLE). Three patients had associated mesial temporal sclerosis. Preoperative 3T MRIs interleaved with nine controls were blindly re-reviewed and categorized according to signal alteration. Pathologic specimens were classified according to the 2011 International League Against Epilepsy (ILAE) classification and compared to MRI studies. Rates of pathology subtypes differed between TLE and ETLE (χ 2 (3) = 8.57, p = 0.04). FCD type I was more frequent in TLE, whereas FCD type II was more frequent in ETLE. In the TLE group, nine patients had temporal tip abnormalities. They all exhibited gray-white matter blurring with decreased myelination and white matter hyperintense signal. Blurring involved the whole temporal tip, not just the area of dysplasia. These patients were less likely to demonstrate cortical thickening compared to those without temporal tip findings (χ 2 (1) = 9.55, p = 0.002). Three of them had FCD Ib, three had FCD IIa, two had FCD IIIa, and one had FCD IIb; MRI features could not entirely distinguish between FCD subtypes. TLE patients showed more pronounced findings than ETLE on MRI (χ 2 (1) = 11.95, p = 0.003, odds ratio [OR] 18.00). In all cases of FCD, isolated blurring was more likely to be associated with FCD II, whereas blurring with decreased myelination was seen with FCD I (χ 2 (6) = 13.07, p = 0.042). Our study described associations between MRI characteristics and pathology in children with FCD and offered a detailed analysis of temporal lobe tip abnormalities and FCD subtypes in children with TLE. These findings may contribute to the

  9. Ictal spitting in left temporal lobe epilepsy: report of three cases.

    Science.gov (United States)

    Caboclo, Luís Otávio Sales Ferreira; Miyashira, Flavia Saori; Hamad, Ana Paula Andrade; Lin, Katia; Carrete, Henrique; Sakamoto, Américo Ceiki; Yacubian, Elza Márcia Targas

    2006-09-01

    Ictal spitting is rarely reported in patients with epilepsy. More often it is observed in patients with temporal lobe epilepsy (TLE) and is presumed to be a lateralizing sign to language nondominant hemisphere. We report three patients with left TLE who had ictal spitting registered during prolonged video-EEG monitoring. Medical charts of all patients with medically refractory partial epilepsy submitted to prolonged video-EEG monitoring in the Epilepsy Unit at UNIFESP during a 3-year period were reviewed, in search of reports of ictal spitting. The clinical, neurophysiological and neuroimaging data of the identified patients were reviewed. Among 136 patients evaluated with prolonged video-EEG monitoring, three (2.2%) presented spitting automatisms during complex partial seizures. All of them were right-handed, and had clear signs of left hippocampal sclerosis on MRI. In two patients, in all seizures in which ictal spitting was observed, EEG seizure onset was seen in the left temporal lobe. In the third patient, ictal onset with scalp electrodes was observed in the right temporal lobe, but semi-invasive monitoring with foramen ovale electrodes revealed ictal onset in the left temporal lobe, confirming false lateralization in surface records. The three patients became seizure-free following left anterior temporal lobectomy. Ictal spitting is a rare finding in patients with epilepsy, and may be considered a localizing sign of seizure onset in the temporal lobe. It may be observed in seizures originating from the left temporal lobe, and thus should not be considered a lateralizing sign of nondominant TLE.

  10. Simulation for scale-up of a confined jet mixer for continuous hydrothermal flow synthesis of nanomaterials

    OpenAIRE

    Ma, CY; Liu, JJ; Zhang, Y; Wang, XZ

    2015-01-01

    Reactor performance of confined jet mixers for continuous hydrothermal flow synthesis of nanomaterials is investigated for the purpose of scale-up from laboratory scale to pilot-plant scale. Computational fluid dynamics (CFD) models were applied to simulate hydrothermal fluid flow, mixing and heat transfer behaviours in the reactors at different volumetric scale-up ratios (up to 26 times). The distributions of flow and heat transfer variables were obtained using ANSYS Fluent with the tracer c...

  11. Differential Growth in Periclinal and Anticlinal Walls during Lobe Formation in Arabidopsis Cotyledon Pavement Cells

    Science.gov (United States)

    Barton, Deborah A.; Law, Andrew M.K.; Overall, Robyn L.

    2015-01-01

    Lobe development in the epidermal pavement cells of Arabidopsis thaliana cotyledons and leaves is thought to take place via tip-like growth on the concave side of lobes driven by localized concentrations of actin filaments and associated proteins, with a predicted role for cortical microtubules in establishing the direction of restricted growth at the convex side. We used homologous landmarks fixed to the outer walls of pavement cells and thin-plate spline analysis to demonstrate that lobes form by differential growth of both the anticlinal and periclinal walls. Most lobes formed within the first 24 h of the cotyledons unfurling, during the period of rapid cell expansion. Cortical microtubules adjacent to the periclinal wall were persistently enriched at the convex side of lobes during development where growth was anisotropic and were less concentrated or absent at the concave side where growth was promoted. Alternating microtubule-enriched and microtubule-free zones at the periclinal wall in neighboring cells predicted sites of new lobes. There was no particular arrangement of cortical actin filaments that could predict where lobes would form. However, drug studies demonstrate that both filamentous actin and microtubules are required for lobe formation. PMID:26296967

  12. Temporal Lobe Epilepsy Surgery Failures: A Review

    Science.gov (United States)

    Harroud, Adil; Bouthillier, Alain; Weil, Alexander G.; Nguyen, Dang Khoa

    2012-01-01

    Patients with temporal lobe epilepsy (TLE) are refractory to antiepileptic drugs in about 30% of cases. Surgical treatment has been shown to be beneficial for the selected patients but fails to provide a seizure-free outcome in 20–30% of TLE patients. Several reasons have been identified to explain these surgical failures. This paper will address the five most common causes of TLE surgery failure (a) insufficient resection of epileptogenic mesial temporal structures, (b) relapse on the contralateral mesial temporal lobe, (c) lateral temporal neocortical epilepsy, (d) coexistence of mesial temporal sclerosis and a neocortical lesion (dual pathology); and (e) extratemporal lobe epilepsy mimicking TLE or temporal plus epilepsy. Persistence of epileptogenic mesial structures in the posterior temporal region and failure to distinguish mesial and lateral temporal epilepsy are possible causes of seizure persistence after TLE surgery. In cases of dual pathology, failure to identify a subtle mesial temporal sclerosis or regions of cortical microdysgenesis is a likely explanation for some surgical failures. Extratemporal epilepsy syndromes masquerading as or coexistent with TLE result in incomplete resection of the epileptogenic zone and seizure relapse after surgery. In particular, the insula may be an important cause of surgical failure in patients with TLE. PMID:22934162

  13. Differential gene expression in dentate granule cells in mesial temporal lobe epilepsy with and without hippocampal sclerosis.

    Science.gov (United States)

    Griffin, Nicole G; Wang, Yu; Hulette, Christine M; Halvorsen, Matt; Cronin, Kenneth D; Walley, Nicole M; Haglund, Michael M; Radtke, Rodney A; Skene, J H Pate; Sinha, Saurabh R; Heinzen, Erin L

    2016-03-01

    Hippocampal sclerosis is the most common neuropathologic finding in cases of medically intractable mesial temporal lobe epilepsy. In this study, we analyzed the gene expression profiles of dentate granule cells of patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis to show that next-generation sequencing methods can produce interpretable genomic data from RNA collected from small homogenous cell populations, and to shed light on the transcriptional changes associated with hippocampal sclerosis. RNA was extracted, and complementary DNA (cDNA) was prepared and amplified from dentate granule cells that had been harvested by laser capture microdissection from surgically resected hippocampi from patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis. Sequencing libraries were sequenced, and the resulting sequencing reads were aligned to the reference genome. Differential expression analysis was used to ascertain expression differences between patients with and without hippocampal sclerosis. Greater than 90% of the RNA-Seq reads aligned to the reference. There was high concordance between transcriptional profiles obtained for duplicate samples. Principal component analysis revealed that the presence or absence of hippocampal sclerosis was the main determinant of the variance within the data. Among the genes up-regulated in the hippocampal sclerosis samples, there was significant enrichment for genes involved in oxidative phosphorylation. By analyzing the gene expression profiles of dentate granule cells from surgically resected hippocampal specimens from patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis, we have demonstrated the utility of next-generation sequencing methods for producing biologically relevant results from small populations of homogeneous cells, and have provided insight on the transcriptional changes associated with this pathology. Wiley Periodicals, Inc. © 2016

  14. Right fronto-limbic atrophy is associated with reduced empathy in refractory unilateral mesial temporal lobe epilepsy.

    Science.gov (United States)

    Toller, Gianina; Adhimoolam, Babu; Rankin, Katherine P; Huppertz, Hans-Jürgen; Kurthen, Martin; Jokeit, Hennric

    2015-11-01

    Refractory mesial temporal lobe epilepsy (MTLE) is the most frequent focal epilepsy and is often accompanied by deficits in social cognition including emotion recognition, theory of mind, and empathy. Consistent with the neuronal networks that are crucial for normal social-cognitive processing, these impairments have been associated with functional changes in fronto-temporal regions. However, although atrophy in unilateral MTLE also affects regions of the temporal and frontal lobes that underlie social cognition, little is known about the structural correlates of social-cognitive deficits in refractory MTLE. In the present study, a psychometrically validated empathy questionnaire was combined with whole-brain voxel-based morphometry (VBM) to investigate the relationship between self-reported affective and cognitive empathy and gray matter volume in 55 subjects (13 patients with right MTLE, 9 patients with left MTLE, and 33 healthy controls). Consistent with the brain regions underlying social cognition, our results show that lower affective and cognitive empathy was associated with smaller volume in predominantly right fronto-limbic regions, including the right hippocampus, parahippocampal gyrus, thalamus, fusiform gyrus, inferior temporal gyrus, dorsomedial and dorsolateral prefrontal cortices, and in the bilateral midbrain. The only region that was associated with both affective and cognitive empathy was the right mesial temporal lobe. These findings indicate that patients with right MTLE are at increased risk for reduced empathy towards others' internal states and they shed new light on the structural correlates of impaired social cognition frequently accompanying refractory MTLE. In line with previous evidence from patients with neurodegenerative disease and stroke, the present study suggests that empathy depends upon the integrity of right fronto-limbic and brainstem regions and highlights the importance of the right mesial temporal lobe and midbrain

  15. Depression in patients with refractory temporal lobe epilepsy

    Directory of Open Access Journals (Sweden)

    Eleonora Borges Gonçalves

    2011-10-01

    Full Text Available OBJECTIVE: To evaluate the comorbidity of depressive disorders in patients with refractory temporal lobe epilepsy (TLE. METHOD: We evaluated 25 consecutive patients with refractory TLE (16 women and 9 men, using semi-structured psychiatric interviews, according to the International Classification of Diseases (ICD-10, and the Beck Depression Inventory. RESULTS: Seventeen of 25 patients (68% had depressive disorder: 6 with dysthymia, three with major depressive episodes and 8 with recurrent depressive disorders. Two (8% were diagnosed with mixed anxiety and depression. Only 5 of 17 patients (29.4% were previously diagnosed with depressive disorder and received prior antidepressant treatment. Duration of epilepsy was significantly higher in patients with depressive disorder (p=0.016, but there was no relationship between depression and seizure frequency. CONCLUSION: This study confirmed that depressive disorders are common and underdiagnosed in patients with TLE refractory to AEDs. Patients with longer duration of epilepsy are at higher risk of having depression.

  16. Relation between fluid intelligence and frontal lobe functioning in older adults.

    Science.gov (United States)

    Isingrini, M; Vazou, F

    1997-01-01

    This study reports the relations among normal aging, intelligence, and frontal lobe functioning. Intelligence tasks and frontal lobe functioning tasks were administered to 107 adults from two age groups (25 to 46 years and 70 to 99 years). Intelligence measures were assessed with two crystallized tests (WAIS Vocabulary and Information subtests), one fluid intelligence test (Cattell's Matrices), and one mixed, crystallized and fluid test (WAIS Similarities subtest). Frontal functioning was assessed using the Wisconsin Card Sorting Test (WCST) and two tests of verbal fluency. Significant age differences in favor of the young were found on the two intelligence tests with a fluid component and on all measures of frontal lobe functioning. Correlational analyses examining the relationship of intelligence measures to frontal variables indicated that these last measures were significantly correlated with only fluid intelligence tests in the elderly group. The implications for the relations among aging, fluid intelligence, and frontal lobe functioning are discussed.

  17. Pesticide Safety for Non-Certified Mixers, Loaders and Applicators = Uso Seguro de Pesticidas para Mezcladores, Cargadores y Aplicadores no Certificados.

    Science.gov (United States)

    Poli, Bonnie; Fluker, Sam S.

    Written in English and Spanish and completely illustrated, this manual provides basic safety information for pesticide workers. Mixers, loaders, and applicators work with pesticides at their greatest strength and have the highest risk of poisoning. Understanding the pesticide label is the first step to pesticide safety. The words…

  18. Effects of mixing technologies on continuous methyl ester production: Comparison of using plug flow, static mixer, and ultrasound clamp

    International Nuclear Information System (INIS)

    Somnuk, Krit; Prasit, Tanongsak; Prateepchaikul, Gumpon

    2017-01-01

    Highlights: • Four types of continuous reactors were compared with methyl ester conversion. • Plug flow, static mixer, ultrasound clamp, SM with ultrasound reactors were tested. • The 16 × 400 W ultrasound clamps were operated at 20 kHz frequency for US reactor. • The US reactor was clearly superior over the other types of continuous reactor. • The US reactor was the most effective alternative with short reactor length. - Abstract: Four types of continuous reactors, namely plug flow reactor (PF), static mixer reactor (SM), ultrasound clamp on tubular reactor (US), and static mixer combined with ultrasound (SM/US) were compared for their purities of methyl ester in biodiesel production from refined palm oil (RPO). The reactor conditions were: KOH 4, 6, 8, 10, and 12 g L −1 , methanol content 20 vol.%, and under 20 L h −1 RPO flow rate at 60 °C temperature. The highest purity of methyl esters: 81.99 wt.% for PF, 95.70 wt.% for SM, 98.98 wt.% for US, and 97.67 wt.% for SM/US, were achieved with 900 mm, 900 mm, 700 mm, and 900 mm reactor lengths respectively, and 12 g L −1 of KOH was used in all cases. The 16 × 400 W ultrasound clamp was operated at 20 kHz frequency, and among short length reactors the US case was more effective than PF, SM, or SM/US. Moreover, ester purity from the US reactor was slightly decreased by the lowest 4 g L −1 KOH. The US reactor was clearly superior over the other types of continuous reactor, and had the potential to reduce KOH consumption by sonochemical effects on the base-catalyzed transesterification reaction.

  19. Mixing of low-dose cohesive drug and overcoming of pre-blending step using a new gentle-wing high-shear mixer granulator.

    Science.gov (United States)

    Alsulays, Bader B; Fayed, Mohamed H; Alalaiwe, Ahmed; Alshahrani, Saad M; Alshetaili, Abdullah S; Alshehri, Sultan M; Alanazi, Fars K

    2018-05-16

    The objective of this study was to examine the influence of drug amount and mixing time on the homogeneity and content uniformity of a low-dose drug formulation during the dry mixing step using a new gentle-wing high-shear mixer. Moreover, the study investigated the influence of drug incorporation mode on the content uniformity of tablets manufactured by different methods. Albuterol sulfate was selected as a model drug and was blended with the other excipients at two different levels, 1% w/w and 5% w/w at impeller speed of 300 rpm and chopper speed of 3000 rpm for 30 min. Utilizing a 1 ml unit side-sampling thief probe, triplicate samples were taken from nine different positions in the mixer bowl at selected time points. Two methods were used for manufacturing of tablets, direct compression and wet granulation. The produced tablets were sampled at the beginning, middle, and end of the compression cycle. An analysis of variance analysis indicated the significant effect (p drug amount on the content uniformity of the powder blend and the corresponding tablets. For 1% w/w and 5% w/w formulations, incorporation of the drug in the granulating fluid provided tablets with excellent content uniformity and very low relative standard deviation (∼0.61%) during the whole tableting cycle compared to direct compression and granulation method with dry incorporation mode of the drug. Overall, gentle-wing mixer is a good candidate for mixing of low-dose cohesive drug and provides tablets with acceptable content uniformity with no need for pre-blending step.

  20. Lung lobe torsion in dogs: 22 cases (1981-1999).

    Science.gov (United States)

    Neath, P J; Brockman, D J; King, L G

    2000-10-01

    To identify breed disposition, postoperative complications, and outcome in dogs with lung lobe torsion. Retrospective study. 22 client-owned dogs. Information on signalment; history; clinical findings; results of clinicopathologic testing, diagnostic imaging, and pleural fluid analysis; surgical treatment; intra- and postoperative complications; histologic findings; and outcome were obtained from medical records. All 22 dogs had pleural effusion; dyspnea was the most common reason for examination. Fifteen dogs were large deep-chested breeds; 5 were toy breeds. Afghan Hounds were overrepresented, compared with the hospital population. One dog was euthanatized without treatment; the remaining dogs underwent exploratory thoracotomy and lung lobectomy. Eleven dogs recovered from surgery without complications, but 3 of these later died of thoracic disease. Four dogs survived to discharge but had clinically important complications within 2 months, including chylothorax, mediastinal mesothelioma, gastric dilatation, and a second lung lobe torsion. Six dogs died or were euthanatized within 2 weeks after surgery because of acute respiratory distress syndrome, pneumonia, septic shock, pneumothorax, or chylothorax. Chylothorax was diagnosed in 8 of the 22 dogs, including 4 Afghan Hounds. Results suggest that lung lobe torsion is rare in dogs and develops most frequently in large deep-chested dogs, particularly Afghan Hounds. Other predisposing causes were not identified, but an association with chylothorax was evident, especially in Afghan Hounds. Prognosis for dogs with lung lobe torsion was fair to guarded.

  1. Metallurgical investigation of 2 austenitic stainless steel sodium mixers cracked in service by thermal fatigue

    International Nuclear Information System (INIS)

    Donati, J.R.; Keroulas, F.de; Masse, J.

    1979-01-01

    Two sodium mixers in the sodium heated steam generator test circuit at the EDF Renardieres centre developed leaks after approximately 7,000 hours operation under power. In both cases the investigation found cracking due to plastic fatigue caused by stresses of thermal origin. In one case the damage is explained solely by the size of the temperature oscillations; in the other case, unfavourable geometry reduced the duration of the initiation phase. Different types of cracking characteristic of thermal fatigue in sodium are presented. (author)

  2. Differential Growth in Periclinal and Anticlinal Walls during Lobe Formation in Arabidopsis Cotyledon Pavement Cells.

    Science.gov (United States)

    Armour, William J; Barton, Deborah A; Law, Andrew M K; Overall, Robyn L

    2015-09-01

    Lobe development in the epidermal pavement cells of Arabidopsis thaliana cotyledons and leaves is thought to take place via tip-like growth on the concave side of lobes driven by localized concentrations of actin filaments and associated proteins, with a predicted role for cortical microtubules in establishing the direction of restricted growth at the convex side. We used homologous landmarks fixed to the outer walls of pavement cells and thin-plate spline analysis to demonstrate that lobes form by differential growth of both the anticlinal and periclinal walls. Most lobes formed within the first 24 h of the cotyledons unfurling, during the period of rapid cell expansion. Cortical microtubules adjacent to the periclinal wall were persistently enriched at the convex side of lobes during development where growth was anisotropic and were less concentrated or absent at the concave side where growth was promoted. Alternating microtubule-enriched and microtubule-free zones at the periclinal wall in neighboring cells predicted sites of new lobes. There was no particular arrangement of cortical actin filaments that could predict where lobes would form. However, drug studies demonstrate that both filamentous actin and microtubules are required for lobe formation. © 2015 American Society of Plant Biologists. All rights reserved.

  3. Image processing analysis of vortex dynamics of lobed jets from three-dimensional diffusers

    International Nuclear Information System (INIS)

    Nastase, Ilinca; Meslem, Amina; El Hassan, Mouhammad

    2011-01-01

    The passive control of jet flows with the aim to enhance mixing and entrainment is of wide practical interest. Our purpose here is to develop new air diffusers for heating ventilating air conditioning systems by using lobed geometry nozzles, in order to ameliorate the users' thermal comfort. Two turbulent six-lobed air jets, issued from a lobed tubular nozzle and an innovative hemispherical lobed nozzle, were studied experimentally. It was shown that the proposed innovative concept of a lobed jet, which can be easily integrated in air diffusion devices, is very efficient regarding induction capability. A vortical dynamics analysis for the two jets is performed using a new method of image processing, namely dynamic mode decomposition. A validation of this method is also proposed suggesting that the dynamical mode decomposition (DMD) image processing method succeeds in capturing the most dominant frequencies of the flow dynamics, which in our case are related to the quite special dynamics of the Kelvin–Helmholtz vortices.

  4. Numerical Investigation of the Performance of Kenics Static Mixers for the Agitation of Shear Thinning Fluids

    OpenAIRE

    A. Mahammedi; H. Ameur; A. Ariss

    2017-01-01

    The laminar flow of non-Newtonian fluids through a Kenics static mixer is investigated by using the CFD (Computational Fluid Dynamics) tool. The working fluids have a shear thinning behavior modeled by the Ostwald De Waele law. We focus on the effect of Reynolds number, fluid properties, twist angle and blade pitch on the flow characteristics and energy cost. The pressure drop information obtained from the simulations was compared to several experimental correlations and data available in the...

  5. Temporal lobe epilepsy: Comparison of CT and MR in 100 patients

    International Nuclear Information System (INIS)

    Schoerner, W.; Meencke, H.J.; Sander, B.; Henkes, H.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1989-01-01

    The value of CT and MR was studied in 100 patients with temporal lobe epilepsy. Axial CT scans were obtained before and after contrast injection. Coronary MR scans were carried out with T 1 -(SE 400/30, GE 315/14) and T 2 -weighted sequences (SE 1600/30 + 70). A circumscribed lesion was demonstrated in fifteen patients by CT and in 25 patients by MR. With the exception of a small area of calcification, all lesions seen on CT could also be recognized on MR. Better sensitivity and improved demonstration of the temporal lobes makes MR the method of choice in the diagnosis of temporal lobe epilepsy. (orig./GDG) [de

  6. Medial temporal lobe

    International Nuclear Information System (INIS)

    Silver, A.J.; Cross, D.T.; Friedman, D.P.; Bello, J.A.; Hilal, S.K.

    1989-01-01

    To better define the MR appearance of hippocampal sclerosis, the authors have reviewed over 500 MR coronal images of the temporal lobes. Many cysts were noted that analysis showed were of choroid-fissure (arachnoid) origin. Their association with seizures was low. A few nontumorous, static, medial temporal lesions, noted on T2-weighted coronal images, were poorly visualized on T1-weighted images and did not enhance with gadolinium. The margins were irregular, involved the hippocampus, and were often associated with focal atrophy. The lesions usually were associated with seizure disorders and specific electroencephalographic changes, and the authors believe they represented hippocampal sclerosis

  7. Dynamic perfusion patterns in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Dupont, Patrick; Paesschen, Wim van; Zaknun, John J.; Maes, Alex; Tepmongkol, Supatporn; Locharernkul, Chaichon; Vasquez, Silvia; Carpintiero, Silvina; Bal, C.S.; Dondi, Maurizio

    2009-01-01

    To investigate dynamic ictal perfusion changes during temporal lobe epilepsy (TLE). We investigated 37 patients with TLE by ictal and interictal SPECT. All ictal injections were performed within 60 s of seizure onset. Statistical parametric mapping was used to analyse brain perfusion changes and temporal relationships with injection time and seizure duration as covariates. The analysis revealed significant ictal hyperperfusion in the ipsilateral temporal lobe extending to subcortical regions. Hypoperfusion was observed in large extratemporal areas. There were also significant dynamic changes in several extratemporal regions: ipsilateral orbitofrontal and bilateral superior frontal gyri and the contralateral cerebellum and ipsilateral striatum. The study demonstrated early dynamic perfusion changes in extratemporal regions probably involved in both propagation of epileptic activity and initiation of inhibitory mechanisms. (orig.)

  8. Dynamic perfusion patterns in temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, Patrick; Paesschen, Wim van [KU Leuven/UZ Gasthuisberg, Nuclear Medicine, Medical Imaging Center and Neurology, Leuven (Belgium); Zaknun, John J. [International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Wagramer Strasse 5, PO BOX 200, Vienna (Austria); University Hospital of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Maes, Alex [KU Leuven/UZ Gasthuisberg, Nuclear Medicine, Medical Imaging Center and Neurology, Leuven (Belgium); AZ Groeninge, Nuclear Medicine, Kortrijk (Belgium); Tepmongkol, Supatporn; Locharernkul, Chaichon [Chulalongkorn University, Nuclear Medicine and Neurology, Bangkok (Thailand); Vasquez, Silvia; Carpintiero, Silvina [Fleni Instituto de Investigaciones Neurologicas, Nuclear Medicine, Buenos Aires (Argentina); Bal, C.S. [All India Institute of Medical Sciences, Nuclear Medicine, New Delhi (India); Dondi, Maurizio [International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Wagramer Strasse 5, PO BOX 200, Vienna (Austria); Ospedale Maggiore, Nuclear Medicine, Bologna (Italy)

    2009-05-15

    To investigate dynamic ictal perfusion changes during temporal lobe epilepsy (TLE). We investigated 37 patients with TLE by ictal and interictal SPECT. All ictal injections were performed within 60 s of seizure onset. Statistical parametric mapping was used to analyse brain perfusion changes and temporal relationships with injection time and seizure duration as covariates. The analysis revealed significant ictal hyperperfusion in the ipsilateral temporal lobe extending to subcortical regions. Hypoperfusion was observed in large extratemporal areas. There were also significant dynamic changes in several extratemporal regions: ipsilateral orbitofrontal and bilateral superior frontal gyri and the contralateral cerebellum and ipsilateral striatum. The study demonstrated early dynamic perfusion changes in extratemporal regions probably involved in both propagation of epileptic activity and initiation of inhibitory mechanisms. (orig.)

  9. Particle doses in the pulmonary lobes of electronic and conventional cigarette users

    International Nuclear Information System (INIS)

    Manigrasso, Maurizio; Buonanno, Giorgio; Stabile, Luca; Morawska, Lidia; Avino, Pasquale

    2015-01-01

    The main aim of the present study was to estimate size segregated doses from e-cigarette aerosols as a function of the airway generation number in lung lobes. After a 2-second puff, 7.7 × 10 10 particles (D Tot ) with a surface area of 3.6 × 10 3  mm 2 (S Tot ), and 3.3 × 10 10 particles with a surface area of 4.2 × 10 3  mm 2 were deposited in the respiratory system for the electronic and conventional cigarettes, respectively. Alveolar and tracheobronchial deposited doses were compared to the ones received by non-smoking individuals in Western countries, showing a similar order of magnitude. Total regional doses (D R ), in head and lobar tracheobronchial and alveolar regions, ranged from 2.7 × 10 9 to 1.3 × 10 10 particles and 1.1 × 10 9 to 5.3 × 10 10 particles, for the electronic and conventional cigarettes, respectively. D R in the right-upper lung lobe was about twice that found in left-upper lobe and 20% greater in right-lower lobe than the left-lower lobe. - Highlights: • Lobar doses were compared for mainstreams of electronic and conventional cigarettes. • Aerosol doses from e-cigarettes were more than double that from conventional ones. • Doses from a 2-s puff exceed the daily doses of a no smoking Australian subject. • Highest deposition densities occurred at the lobar bronchi. • Aerosol deposition was greater in the right than in the left lung lobes. - Lobar bronchi and right lung lobes represent sites where effects of the aerosol from e-cigarette smoke may be more likely to occur

  10. Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray microbeam.

    Science.gov (United States)

    Graceffa, Rita; Nobrega, R Paul; Barrea, Raul A; Kathuria, Sagar V; Chakravarthy, Srinivas; Bilsel, Osman; Irving, Thomas C

    2013-11-01

    Small-angle X-ray scattering (SAXS) is a well established technique to probe the nanoscale structure and interactions in soft matter. It allows one to study the structure of native particles in near physiological environments and to analyze structural changes in response to variations in external conditions. The combination of microfluidics and SAXS provides a powerful tool to investigate dynamic processes on a molecular level with sub-millisecond time resolution. Reaction kinetics in the sub-millisecond time range has been achieved using continuous-flow mixers manufactured using micromachining techniques. The time resolution of these devices has previously been limited, in part, by the X-ray beam sizes delivered by typical SAXS beamlines. These limitations can be overcome using optics to focus X-rays to the micrometer size range providing that beam divergence and photon flux suitable for performing SAXS experiments can be maintained. Such micro-SAXS in combination with microfluidic devices would be an attractive probe for time-resolved studies. Here, the development of a high-duty-cycle scanning microsecond-time-resolution SAXS capability, built around the Kirkpatrick-Baez mirror-based microbeam system at the Biophysics Collaborative Access Team (BioCAT) beamline 18ID at the Advanced Photon Source, Argonne National Laboratory, is reported. A detailed description of the microbeam small-angle-scattering instrument, the turbulent flow mixer, as well as the data acquisition and control and analysis software is provided. Results are presented where this apparatus was used to study the folding of cytochrome c. Future prospects for this technique are discussed.

  11. Visualization of diffusion mixing in a micro-mixer with flow paths fabricated by photolithography

    Science.gov (United States)

    Horiuchi, Toshiyuki; Morizane, Yuta

    2017-09-01

    Mixing processes of two liquids were investigated by visualizing the mixing when they were simultaneously injected in a micro-mixer with lithographically fabricated Y-shape flow paths, and the mixing phenomena was analyzed in detail. To visualize the mixing, flows were observed by an optical microscope, and a clearly detectable chemical reaction was utilized. As the two liquids, a transparent aqueous solution of a strong alkali and a phenolphthalein ethanol solution were used. When they were simultaneously injected in Y-shape flow paths of a micro-mixer, they flowed at first in parallel along the joined path as laminar flows. This is because the Reynolds' number became very small caused by the narrow flow-path widths of 50-100 μm. However, because two liquids were always contacted at the boundary, they were gradually mixed by diffusion, and the color of the mixed parts changed to vivid red. For this reason, it was able to measure the diffusion distance from the flow path center. Because the flow speeds were much faster than the diffusion speeds, the area colored in red did not depend on the time but depended on the distance from the joint point. It was known that the distance from the joint point corresponded to the time for mixing the liquids by the diffusion. It was clarified that the diffusion distance x was proportional to the square root of the diffusion time t or the distance from the joint point. The calculated diffusion coefficient D was (0.87-1.00)×10-9 m2/s.

  12. Prevalence of resistant occipital lobe epilepsy associated with celiac disease in children.

    Science.gov (United States)

    Dai, Alper I; Akcali, Aylin; Varan, Celal; Demiryürek, Abdullah T

    2014-06-01

    Celiac disease (CD) is a chronic, inflammatory autoimmune disorder caused by intolerance to ingested gluten. Increased frequency of CD has been reported in occipital lobe epilepsy. The aim of the present study is to investigate the frequency of CD among children followed up due to epilepsy and diagnosed with epileptic activity in the occipital lobe in at least one electroencephalography (EEG) test. For this research, 90 pediatric epilepsy patients with epileptic activity in the occipital lobe were enrolled in the study group, while the control group comprised of 100 healthy children. In addition to the EEG examination, tissue transglutaminase (tTG) antibody was determined on duodenal biopsy. None of the healthy children in the control group was positive in terms of the tTG antibody test used to scan CD. In the group with epileptic activity in the occipital lobe, two patients out of 90 were tTG antibody positive. The seroprevalence was 1/45 (2.22 %) in this group. These two patients were diagnosed with CD based on the endoscopic duodenal biopsy. In these patients, the seizures were uncontrollable through monotherapy. Our results showed that the prevalence of CD is observed to be higher than the normal population among the patients with occipital lobe epilepsy. This type of seizure disorder seems to be more resistant to monotherapy, compared with other types of occipital epilepsy. Therefore, screening for CD is recommended in children with resistant epileptic activity in the occipital lobe.

  13. Roche-Lobe overflow in X-ray binaries, ch. 2

    International Nuclear Information System (INIS)

    Savonije, G.J.

    1977-01-01

    It is examined whether Roche-lobe overflow can be the main mechanism of mass transfer that powers the low-mass as well as the massive X-ray binaries. Detailed numerical computations of the initial phase of Roche-lobe overflow were performed in order to determine the precise time development of the mass transfer from normal stars with masses ranging from 1.5 M(sun) up to 20 M(sun) to compact companions with masses of 1 and 1.5 M(sun). The binary code includes a simplified hydrodynamical treatment of Roche-lobe overflow. For massive primaries this hydrodynamical treatment appears to result in much longer X-ray lifetimes than obtained in previous investigations. The calculations also include effects of slow, non-synchronous rotation of the contact star and loss of mass and angular momentum from the binary system. For Her X-1 and Cen X-3 X-ray lifetimes of the order of 10 5 and 10 4 yrs are predicted, respectively

  14. Redefining Lumpectomy Using a Modification of the Sick Lobe Hypothesis and Ductal Anatomy

    International Nuclear Information System (INIS)

    Dooley, W.; Bong, J.; Parker, J

    2011-01-01

    Objectives. The Sick Lobe hypothesis states that breast cancers evolve from entire lobes or portions of lobes of the breast where initiation events have occurred early in development. The implication is that some cancers are isolated events and others are truly multi-focal but limited to single lobar-ductal units. Methods. This is a single surgeon retrospective review of early stage breast cancer lumpectomy patients treated from 1/2000 to 2/2005. Ductal endoscopy was used direct lumpectomy surgical margins by defining ductal anatomy and mapping proliferative changes within the sick lobe for complete excision. Results. Breast conservation surgery for stage 02 breast cancer with an attempt to perform endoscopy in association with therapeutic lumpectomy was performed in 554 patients (successful endoscopy in 465 cases). With an average followup of >5 years for the entire group, annual hazard rate for local failure in traditional lumpectomy without ductal mapping was 0.97%/yr. and for lumpectomy with ductal mapping and excision of entire sick lobe was 0.18%/yr. With endoscopy, 42% of patients were found to have extensive disease within their sick lobe. Conclusions. Targeting breast cancer lumpectomy using endoscopy and excision of regional associated proliferation seems associated with lower recurrence in this non-randomized series

  15. Design and implementation of a rapid-mixer flow cell for time-resolved infrared microspectroscopy

    International Nuclear Information System (INIS)

    Marinkovic, Nebojsa S.; Adzic, Aleksandar R.; Sullivan, Michael; Kovacs, Kevin; Miller, Lisa M.; Rousseau, Denis L.; Yeh, Syun-Ru; Chance, Mark R.

    2000-01-01

    A rapid mixer for the analysis of reactions in the millisecond and submillisecond time domains by Fourier-transform infrared microspectroscopy has been constructed. The cell was tested by examination of cytochrome-c folding kinetics. The device allows collection of full infrared spectral data on millisecond and faster time scales subsequent to chemical jump reaction initiation. The data quality is sufficiently good such that spectral fitting techniques could be applied to analysis of the data. Thus, this method provides an advantage over kinetic measurements at single wavelengths using infrared laser or diode sources, particularly where band overlap exists

  16. The Azygous Lobe of the Lung: in the Case of Lung Cancer.

    Science.gov (United States)

    Darlong, L M; Ram, Dharma; Sharma, Ashwani; Sharma, Anil Kumar; Iqbal, Sayed Assif; Nagar, Anand; Hazarika, Dibyamohan

    2017-06-01

    The azygous lobe of the lung is an uncommon developmental anomaly. Its surgical importance is hardly being described in literature. Here, we are presenting a case of lung cancer with incidental azygous lobe, with its surgical relevance during lung cancer surgery.

  17. Temporal lobe structures and facial emotion recognition in schizophrenia patients and nonpsychotic relatives.

    Science.gov (United States)

    Goghari, Vina M; Macdonald, Angus W; Sponheim, Scott R

    2011-11-01

    Temporal lobe abnormalities and emotion recognition deficits are prominent features of schizophrenia and appear related to the diathesis of the disorder. This study investigated whether temporal lobe structural abnormalities were associated with facial emotion recognition deficits in schizophrenia and related to genetic liability for the disorder. Twenty-seven schizophrenia patients, 23 biological family members, and 36 controls participated. Several temporal lobe regions (fusiform, superior temporal, middle temporal, amygdala, and hippocampus) previously associated with face recognition in normative samples and found to be abnormal in schizophrenia were evaluated using volumetric analyses. Participants completed a facial emotion recognition task and an age recognition control task under time-limited and self-paced conditions. Temporal lobe volumes were tested for associations with task performance. Group status explained 23% of the variance in temporal lobe volume. Left fusiform gray matter volume was decreased by 11% in patients and 7% in relatives compared with controls. Schizophrenia patients additionally exhibited smaller hippocampal and middle temporal volumes. Patients were unable to improve facial emotion recognition performance with unlimited time to make a judgment but were able to improve age recognition performance. Patients additionally showed a relationship between reduced temporal lobe gray matter and poor facial emotion recognition. For the middle temporal lobe region, the relationship between greater volume and better task performance was specific to facial emotion recognition and not age recognition. Because schizophrenia patients exhibited a specific deficit in emotion recognition not attributable to a generalized impairment in face perception, impaired emotion recognition may serve as a target for interventions.

  18. Occipital lobe infarction and positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tagawa, Koichi; Nagata, Ken; Shishido, Fumio (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1990-08-01

    Even though the PET study revealed a total infarct in the territory of the left PCA in our 3 cases of pure alesia, it is still obscure which part of the left occipital lobe is most closely associated with the occurrence of the pure alexia. In order to elucidate the intralobar localization of the pure alexia, it is needed to have an ideal case who shows an pure alexia due to the localized lesion within the left occipital lobe. Furthermore, high-resolution PET scanner will circumvent the problem in detecting the metabolism and blood flow in the corpus callosum which plays an important role in the pathogenesis. We have shown that the occlusion of the right PCA also produced a left unilateral agnosia which is one of the common neurological signs in the right MCA infarction. To tell whether the responsible lesion for the unilateral spatial agnosia differs between the PCA occlusion and the MCA occlusion, the correlation study should be carried out in a greater number of the subjects. Two distinctive neuropsychological manifestations, cerebral color blidness and prosopagnosia, have been considered to be produced by the bilateral occipital lesion. The PET studies disclosed reduction of blood flow and oxygen metabolism in both occipital lobes in our particular patient who exibited cerebral color blindness and posopagnosia. (author).

  19. Occipital lobe infarction and positron emission tomography

    International Nuclear Information System (INIS)

    Tagawa, Koichi; Nagata, Ken; Shishido, Fumio

    1990-01-01

    Even though the PET study revealed a total infarct in the territory of the left PCA in our 3 cases of pure alesia, it is still obscure which part of the left occipital lobe is most closely associated with the occurrence of the pure alexia. In order to elucidate the intralobar localization of the pure alexia, it is needed to have an ideal case who shows an pure alexia due to the localized lesion within the left occipital lobe. Furthermore, high-resolution PET scanner will circumvent the problem in detecting the metabolism and blood flow in the corpus callosum which plays an important role in the pathogenesis. We have shown that the occlusion of the right PCA also produced a left unilateral agnosia which is one of the common neurological signs in the right MCA infarction. To tell whether the responsible lesion for the unilateral spatial agnosia differs between the PCA occlusion and the MCA occlusion, the correlation study should be carried out in a greater number of the subjects. Two distinctive neuropsychological manifestations, cerebral color blidness and prosopagnosia, have been considered to be produced by the bilateral occipital lesion. The PET studies disclosed reduction of blood flow and oxygen metabolism in both occipital lobes in our particular patient who exibited cerebral color blindness and posopagnosia. (author)

  20. Design of 12-phase, 2-stage Harmonic Rejection Mixer for TV Tuners

    Directory of Open Access Journals (Sweden)

    D. Lee

    2016-06-01

    Full Text Available A two-stage 12-phase harmonic rejection mixer (HRM for TV tuners is proposed in order to reject the local oscillator (LO harmonics up to the ninth order. The proposed weighing scheme for 12-phase, 2-stage harmonic mixing can reduce the harmonic rejection (HR sensitivity to the amplitude error caused by irrational numbers such as . To verify this HR, the 2-stage HR circuit is designed with baseband gm weighting in order to save power and improve the HR ratios without calibration. The proposed HRM achieves the third to ninth worst HR ratios, more than 55 dB, according to Monte Carlo simulations. It consumes 6.5 mA under a 2.5 V supply voltage.

  1. Hot-Electron Bolometer Mixers on Silicon-on-Insulator Substrates for Terahertz Frequencies

    Science.gov (United States)

    Skalare, Anders; Stern, Jeffrey; Bumble, Bruce; Maiwald, Frank

    2005-01-01

    A terahertz Hot-Electron Bolometer (HEB) mixer design using device substrates based on Silicon-On-Insulator (SOI) technology is described. This substrate technology allows very thin chips (6 pm) with almost arbitrary shape to be manufactured, so that they can be tightly fitted into a waveguide structure and operated at very high frequencies with only low risk for power leakages and resonance modes. The NbTiN-based bolometers are contacted by gold beam-leads, while other beamleads are used to hold the chip in place in the waveguide test fixture. The initial tests yielded an equivalent receiver noise temperature of 3460 K double-sideband at a local oscillator frequency of 1.462 THz and an intermediate frequency of 1.4 GHz.

  2. Preoperative visual field deficits in temporal lobe epilepsy

    Directory of Open Access Journals (Sweden)

    Sanjeet S. Grewal

    2017-01-01

    Full Text Available Surgical resection and laser thermoablation have been used to treat drug resistant epilepsy with good results. However, they are not without risk. One of the most commonly reported complications of temporal lobe surgery is contralateral superior homonymous quadrantanopsia. We describe a patient with asymptomatic preoperative quadrantanopsia fortuitously discovered as part of our recently modified protocol to evaluate patients prior to temporal lobe epilepsy surgery. This visual field deficit was subtle and not detected on routine clinical neurological examination. While we understand that this is a single case, we advocate further study for more detailed preoperative visual field examinations to characterize the true incidence of postoperative visual field lesions.

  3. Transient response of two lobe aerodynamic journal bearing

    Directory of Open Access Journals (Sweden)

    Saurabh Kumar Yadav

    2018-03-01

    Full Text Available The dynamic behavior of a rotor-dynamic system is greatly affected by the performance of aerodynamic bearing and the performance of bearing is characterized by the stiffness and damping coefficients. In the present work, stiffness and damping coefficients of bearing are computed and the performance of the bearing is greatly changed with the change in bearing air film profile. The effect of lobe offset factors on the transient performance of aerodynamic bearing is presented. Bifurcation and Poincare diagrams of two lobe journal bearing have been presented for different offset factors. A bearing designer can judge the bearing performance based on bifurcation diagrams.

  4. Charge-Domain Signal Processing of Direct RF Sampling Mixer with Discrete-Time Filters in Bluetooth and GSM Receivers

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available RF circuits for multi-GHz frequencies have recently migrated to low-cost digital deep-submicron CMOS processes. Unfortunately, this process environment, which is optimized only for digital logic and SRAM memory, is extremely unfriendly for conventional analog and RF designs. We present fundamental techniques recently developed that transform the RF and analog circuit design complexity to digitally intensive domain for a wireless RF transceiver, so that it enjoys benefits of digital and switched-capacitor approaches. Direct RF sampling techniques allow great flexibility in reconfigurable radio design. Digital signal processing concepts are used to help relieve analog design complexity, allowing one to reduce cost and power consumption in a reconfigurable design environment. The ideas presented have been used in Texas Instruments to develop two generations of commercial digital RF processors: a single-chip Bluetooth radio and a single-chip GSM radio. We further present details of the RF receiver front end for a GSM radio realized in a 90-nm digital CMOS technology. The circuit consisting of low-noise amplifier, transconductance amplifier, and switching mixer offers 32.5 dB dynamic range with digitally configurable voltage gain of 40 dB down to 7.5 dB. A series of decimation and discrete-time filtering follows the mixer and performs a highly linear second-order lowpass filtering to reject close-in interferers. The front-end gains can be configured with an automatic gain control to select an optimal setting to form a trade-off between noise figure and linearity and to compensate the process and temperature variations. Even under the digital switching activity, noise figure at the 40 dB maximum gain is 1.8 dB and +50 dBm IIP2 at the 34 dB gain. The variation of the input matching versus multiple gains is less than 1 dB. The circuit in total occupies 3.1 mm 2 . The LNA, TA, and mixer consume less than 15.3 mA at a supply voltage of 1.4 V.

  5. Charge-Domain Signal Processing of Direct RF Sampling Mixer with Discrete-Time Filters in Bluetooth and GSM Receivers

    Directory of Open Access Journals (Sweden)

    Ho Yo-Chuol

    2006-01-01

    Full Text Available RF circuits for multi-GHz frequencies have recently migrated to low-cost digital deep-submicron CMOS processes. Unfortunately, this process environment, which is optimized only for digital logic and SRAM memory, is extremely unfriendly for conventional analog and RF designs. We present fundamental techniques recently developed that transform the RF and analog circuit design complexity to digitally intensive domain for a wireless RF transceiver, so that it enjoys benefits of digital and switched-capacitor approaches. Direct RF sampling techniques allow great flexibility in reconfigurable radio design. Digital signal processing concepts are used to help relieve analog design complexity, allowing one to reduce cost and power consumption in a reconfigurable design environment. The ideas presented have been used in Texas Instruments to develop two generations of commercial digital RF processors: a single-chip Bluetooth radio and a single-chip GSM radio. We further present details of the RF receiver front end for a GSM radio realized in a 90-nm digital CMOS technology. The circuit consisting of low-noise amplifier, transconductance amplifier, and switching mixer offers dB dynamic range with digitally configurable voltage gain of 40 dB down to dB. A series of decimation and discrete-time filtering follows the mixer and performs a highly linear second-order lowpass filtering to reject close-in interferers. The front-end gains can be configured with an automatic gain control to select an optimal setting to form a trade-off between noise figure and linearity and to compensate the process and temperature variations. Even under the digital switching activity, noise figure at the 40 dB maximum gain is 1.8 dB and dBm IIP2 at the 34 dB gain. The variation of the input matching versus multiple gains is less than 1 dB. The circuit in total occupies 3.1 . The LNA, TA, and mixer consume less than mA at a supply voltage of 1.4 V.

  6. Temporal plus epilepsy is a major determinant of temporal lobe surgery failures.

    Science.gov (United States)

    Barba, Carmen; Rheims, Sylvain; Minotti, Lorella; Guénot, Marc; Hoffmann, Dominique; Chabardès, Stephan; Isnard, Jean; Kahane, Philippe; Ryvlin, Philippe

    2016-02-01

    Reasons for failed temporal lobe epilepsy surgery remain unclear. Temporal plus epilepsy, characterized by a primary temporal lobe epileptogenic zone extending to neighboured regions, might account for a yet unknown proportion of these failures. In this study all patients from two epilepsy surgery programmes who fulfilled the following criteria were included: (i) operated from an anterior temporal lobectomy or disconnection between January 1990 and December 2001; (ii) magnetic resonance imaging normal or showing signs of hippocampal sclerosis; and (iii) postoperative follow-up ≥ 24 months for seizure-free patients. Patients were classified as suffering from unilateral temporal lobe epilepsy, bitemporal epilepsy or temporal plus epilepsy based on available presurgical data. Kaplan-Meier survival analysis was used to calculate the probability of seizure freedom over time. Predictors of seizure recurrence were investigated using Cox proportional hazards model. Of 168 patients included, 108 (63.7%) underwent stereoelectroencephalography, 131 (78%) had hippocampal sclerosis, 149 suffered from unilateral temporal lobe epilepsy (88.7%), one from bitemporal epilepsy (0.6%) and 18 (10.7%) from temporal plus epilepsy. The probability of Engel class I outcome at 10 years of follow-up was 67.3% (95% CI: 63.4-71.2) for the entire cohort, 74.5% (95% CI: 70.6-78.4) for unilateral temporal lobe epilepsy, and 14.8% (95% CI: 5.9-23.7) for temporal plus epilepsy. Multivariate analyses demonstrated four predictors of seizure relapse: temporal plus epilepsy (P temporal lobe surgery failure was 5.06 (95% CI: 2.36-10.382) greater in patients with temporal plus epilepsy than in those with unilateral temporal lobe epilepsy. Temporal plus epilepsy represents a hitherto unrecognized prominent cause of temporal lobe surgery failures. In patients with temporal plus epilepsy, anterior temporal lobectomy appears very unlikely to control seizures and should not be advised. Whether larger

  7. Activation on occipital lobe in children with abacus mental calculation training: an fMRI study

    International Nuclear Information System (INIS)

    Shen Xiaojun; Long Jinfeng; Zhao Kunyuan; Li Lixin; Sun Jining; Wang Bin

    2011-01-01

    Objective: By exploring the activation on occipital lobe in children with and without abacus mental calculation training when they engaged in different calculation tasks with functional magnetic resonance imaging (fMRI), to identify the possible mechanism of occipital lobe in abacus mental calculation. Methods: fMRI was performed in children trained with and without (sixteen in each group) abacus mental calculation when they engaged in addition, subtraction. multiplication, division, and number-object control judging tasks. The data processing and statistical analysis were performed on SPM 2.0 (statistical parametric mapping 2.0) and the related-brain functional areas were identified. The activation on occipital lobe was observed carefully. The difference in activated areas of occipital lobe was statistically significant between two groups engaged in different tasks of calculations (P<0.01). Result: Bilateral occipital lobe, especially in the cuneus and lingual gyrus, were activated in children trained with abacus mental calculation. The main activated area was lingual gyrus in children without abacus mental calculation. Conclusion: The occipital lobe participates visuospatial processing in the abacus mental calculations. The neuromechanism maybe account for the specific activation in occipital lobe. (authors)

  8. Fuel Continuous Mixer ? an Approach Solution to Use Straight Vegetable Oil for Marine Diesel Engines

    OpenAIRE

    Đặng Van Uy; Tran The Nam

    2018-01-01

    The vegetable oil is well known as green fuel for diesel engines due to its low sunphur content and renewable stock. However, there are some problems raising when vegetable oil is used as fuel for diesel engines such as highly effected by cold weather, lower general efficiency, separation in layer if mixed with diesel oil and so on. To overcome that disadvantiges, the authors propose a new idea that to use a continuous fuel mixer to blend vegetable oil with diesel oil to make so called a mixe...

  9. The lobe to plasma sheet boundary layer transition: Theory and observations

    International Nuclear Information System (INIS)

    Schriver, D.; Ashour-Abdalla, M.; Treumann, R.; Nakamura, M.; Kistler, L.M.

    1990-01-01

    The lobe and the plasma sheet boundary layer in the Earth's magnetotail are regions of different plasma conditions and share a common interface. The transition from the lobe to the plasma sheet boundary layer is examined here using AMPTE/IRM data. When the satellite crossed from the lobe to the plasma sheet boundary layer, intense narrow banded wave bursts at 1 kHz were observed an d then broadband electrostatic noise (BEN) immediately followed. Simultaneous with the onset of BEN, high energy earthward streaming proton beams at > 40 keV (> 2,700 km/s) were detected. These results are used as input into a numerical simulation to study ion beam instabilities in the PSBL

  10. Microencephaloceles: another dual pathology of intractable temporal lobe epilepsy in childhood.

    Science.gov (United States)

    Aquilina, Kristian; Clarke, Dave F; Wheless, James W; Boop, Frederick A

    2010-04-01

    Temporal lobe encephaloceles can be associated with temporal lobe epilepsy. The authors report on the case of an adolescent with multiple microencephaloceles, in the anterolateral middle fossa floor, identified at surgery (temporal lobectomy) for intractable partial-onset seizures of temporal origin. Magnetic resonance imaging revealed only hippocampal atrophy. Subdural electrodes demonstrated ictal activity arising primarily from the anterior and lateral temporal lobe, close to the microencephaloceles, spreading to the anterior and posterior mesial structures. Pathological examination revealed diffuse temporal gliosis involving the hippocampus, together with microdysgenesis of the amygdala. The literature on epilepsy secondary to encephaloceles is reviewed and the contribution of the microencephaloceles to the seizure disorder in this patient is discussed.

  11. Corticotropin-releasing factor (CRF) receptors in intermediate lobe of the pituitary: Biochemical characterization and autoradiographic localization

    International Nuclear Information System (INIS)

    Grigoriadis, D.E.; De Souza, E.B.

    1989-01-01

    CRF receptors were characterized using radioligand binding and chemical affinity cross-linking techniques and localized using autoradiographic techniques in porcine, bovine and rat pituitaries. The binding of 125I-[Tyr0]-ovine CRF (125I-oCRF) to porcine anterior and neurointermediate lobe membranes was saturable and of high affinity with comparable KD values (200-600 pM) and receptor densities (100-200 fmoles/mg protein). The pharmacological rank order of potencies for various analogs and fragments of CRF in inhibiting 125I-oCRF binding in neurointermediate lobe was characteristic of the well-established CRF receptor in anterior pituitary. Furthermore, the binding of 125I-oCRF to both anterior and neurointermediate lobes of the pituitary was guanine nucleotide-sensitive. Affinity cross-linking studies revealed that the molecular weight of the CRF binding protein in rat intermediate lobe was identical to that in rat anterior lobe (Mr = 75,000). While the CRF binding protein in the anterior lobes of porcine and bovine pituitaries had identical molecular weights to CRF receptors in rat pituitary (Mr = 75,000), the molecular weight of the CRF binding protein in porcine and bovine intermediate lobe was slightly higher (Mr = 78,000). Pituitary autoradiograms from the three species showed specific binding sites for 125I-oCRF in anterior and intermediate lobes, with none being apparent in the posterior pituitary. The identification of CRF receptors in the intermediate lobe with comparable characteristics to those previously identified in the anterior pituitary substantiate further the physiological role of CRF in regulating intermediate lobe hormone secretion

  12. Reducing of internal resistance lithium ion battery using glucose addition

    Science.gov (United States)

    Salim, Andri Pratama; Hafidlullah, Noor; Purwanto, Agus

    2016-02-01

    There are two indicators of battery performance, i.e : capacity and the internal resistance of battery. In this research, the affect of glucose addition to decrease the internal resistance of lithium battery was investigated. The ratio of glucose addition were varied at weight ratio 1%, 3%, and 5% and one mixtures without glucose addition. Lithium ferri phosphate (LiFePO4), polyvinylidene fluoride (PVDF), acetylene black (AB) and glucose were materials that used in this study. Both of mixtures were mixed in the vacuum mixer until became homogeneous. The slurry was coated on an aluminium foil sheet and the coated thickness was 200 µm. The performance of battery lithium was examined by Eight Channel Battery Analyzer and the Internal resistance was examined by Internal Resistance of Battery Meter. The result from all analyzer were showed that the internal resistance reduced as well as the battery capacity. The best internal resistance value is owned by mixtures with 3wt% ratio glucose addition. It has an internal resistance value about 64 miliohm.

  13. Reducing of internal resistance lithium ion battery using glucose addition

    International Nuclear Information System (INIS)

    Salim, Andri Pratama; Hafidlullah, Noor; Purwanto, Agus

    2016-01-01

    There are two indicators of battery performance, i.e : capacity and the internal resistance of battery. In this research, the affect of glucose addition to decrease the internal resistance of lithium battery was investigated. The ratio of glucose addition were varied at weight ratio 1%, 3%, and 5% and one mixtures without glucose addition. Lithium ferri phosphate (LiFePO 4 ), polyvinylidene fluoride (PVDF), acetylene black (AB) and glucose were materials that used in this study. Both of mixtures were mixed in the vacuum mixer until became homogeneous. The slurry was coated on an aluminium foil sheet and the coated thickness was 200 µm. The performance of battery lithium was examined by Eight Channel Battery Analyzer and the Internal resistance was examined by Internal Resistance of Battery Meter. The result from all analyzer were showed that the internal resistance reduced as well as the battery capacity. The best internal resistance value is owned by mixtures with 3wt% ratio glucose addition. It has an internal resistance value about 64 miliohm

  14. Reducing of internal resistance lithium ion battery using glucose addition

    Energy Technology Data Exchange (ETDEWEB)

    Salim, Andri Pratama; Hafidlullah, Noor; Purwanto, Agus, E-mail: aguspurw@gmail.com [Research Group of Battery & Advanced Material, Department of Chemical Engineering, Sebelas Maret University, Jl. Ir. Sutami 36 A Kentingan, Surakarta Indonesia 57126 (Indonesia)

    2016-02-08

    There are two indicators of battery performance, i.e : capacity and the internal resistance of battery. In this research, the affect of glucose addition to decrease the internal resistance of lithium battery was investigated. The ratio of glucose addition were varied at weight ratio 1%, 3%, and 5% and one mixtures without glucose addition. Lithium ferri phosphate (LiFePO{sub 4}), polyvinylidene fluoride (PVDF), acetylene black (AB) and glucose were materials that used in this study. Both of mixtures were mixed in the vacuum mixer until became homogeneous. The slurry was coated on an aluminium foil sheet and the coated thickness was 200 µm. The performance of battery lithium was examined by Eight Channel Battery Analyzer and the Internal resistance was examined by Internal Resistance of Battery Meter. The result from all analyzer were showed that the internal resistance reduced as well as the battery capacity. The best internal resistance value is owned by mixtures with 3wt% ratio glucose addition. It has an internal resistance value about 64 miliohm.

  15. Morphology and morphometry of the caudate lobe of the liver in two populations.

    Science.gov (United States)

    Sagoo, Mandeep Gill; Aland, R Claire; Gosden, Edward

    2018-01-01

    The caudate lobe of the liver has portal blood supply and hepatic vein drainage independent of the remainder of the liver and may be differentially affected in liver pathologies. Ultrasonographic measurement of the caudate lobe can be used to generate hepatic indices that may indicate cirrhosis. This study investigated the relationship of metrics of the caudate lobe and other morphological features of human livers from a northwest Indian Punjabi population (n = 50) and a UK Caucasian population (n = 25), which may affect the calculation of hepatic indices. The width of the right lobe of the liver was significantly smaller, while the anteroposterior diameter of the caudate lobe and both Harbin's Index and the Hess Index scores were significantly larger in NWI livers than in UKC livers. The Hess Index score, in particular, is much larger in the NWI population (265 %, p liver. These differences may affect the calculation of hepatic indices, resulting in a greater percentage of false positives of cirrhosis in the NWI population. Population-specific data are required to correctly determine normal ranges.

  16. Visual field defects after temporal lobe resection for epilepsy

    DEFF Research Database (Denmark)

    Steensberg, Alvilda T; Olsen, Ane Sophie; Litman, Minna

    2018-01-01

    PURPOSE: To determine visual field defects (VFDs) using methods of varying complexity and compare results with subjective symptoms in a population of newly operated temporal lobe epilepsy patients. METHODS: Forty patients were included in the study. Two patients failed to perform VFD testing...... symptoms were only reported by 28% of the patients with a VFD and in two of eight (sensitivity=25%) with a severe VFD. Most patients (86%) considered VFD information mandatory. CONCLUSION: VFD continue to be a frequent adverse event after epilepsy surgery in the medial temporal lobe and may affect...

  17. The study of kinetics of uranyl nitrate extraction and reextraction, di-n-butylphosphoric acid reextraction in the flow mixer in the system aqueous solutions - tri-n-butyl phosphate in diluent

    International Nuclear Information System (INIS)

    Shchepetil'nikov, N.N.; Timofeev, A.N.; Kharitonov, V.V.

    1992-01-01

    Kinetics of uranyl nitrate and HNO 3 extraction and reextraction in a flow-type mixer for the system 30 vol.% TBP in extractant dearomatized diluent (EDD) was studied. Kinetics of dibutylphosphate acid reextraction was considered and the influence of uranium and zirconium presence on the process was investigated. It is shown that in laboratory mixer of continuous action in case of phase contact duration of 1 min. in system 30 % solution of TBP in EDD extraction sufficiently similar to equilibrium extraction of uranyl nitrate and nitric acid during their extraction and reextraction is achieved

  18. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Neurologia e Psicologia Medica]. E-mail: fgraeff@keynet.com.br; Santos, A.C. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Clinica Medica; Guimaraes, F.S. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Farmacologia

    2003-07-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t{sub 21} = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t{sub 21} = 1.99, P = 0.06), right amygdala (8%, t{sub 21} = 1.83, P = 0.08), left amygdala (5%, t{sub 21} = 1.78, P 0.09) and left hippocampus (9%, t{sub 21} = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  19. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G.; Santos, A.C.; Guimaraes, F.S.

    2003-01-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t 21 = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t 21 = 1.99, P = 0.06), right amygdala (8%, t 21 = 1.83, P = 0.08), left amygdala (5%, t 21 = 1.78, P 0.09) and left hippocampus (9%, t 21 = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  20. Mirror Focus in a Patient with Intractable Occipital Lobe Epilepsy

    OpenAIRE

    Kim, Jiyoung; Shin, Hae kyung; Hwang, Kyoung Jin; Choi, Su Jung; Joo, Eun Yeon; Hong, Seung Bong; Hong, Seung Chul; Seo, Dae-Won

    2014-01-01

    Mirror focus is one of the evidence of progression in epilepsy, and also has practical points for curative resective epilepsy surgery. The mirror foci are related to the kindling phenomena that occur through interhemispheric callosal or commissural connections. A mirror focus means the secondary epileptogenic foci develop in the contralateral hemispheric homotopic area. Thus mirror foci are mostly reported in patients with temporal or frontal lobe epilepsy, but not in occipital lobe epilepsy....

  1. Lateral chest radiographic findings in lobar collapse of the left lung : the distance between both upper lobe bronchi

    International Nuclear Information System (INIS)

    Chin, G. H.; Sung, D. W.; Yoon, Y.; Kim, H. C.

    1996-01-01

    To evaluate the distance between both upper love bronchi on lateral radiographs and its change in left upper or lower lobe collapse. 144 true lateral radiographs were analyzed on which both upper lobe bronchi were clearly identified. They included 116 normal cases, 11 cases of left upper lobe collapse, 13 of left lower lobe collapse, and 4 cases of left lower lobe lobectomy. Line A was drawn parallel to the vertebral end plate through the upper margin of the lift upper lobe bronchus. Line B was drawn parallel to line A through the upper margin of the right upper love bronchus. The shortest distance between line A and line B was measured as the distance between both upper lobe bronchi. In normal cases, the mean value of the distance was 2.19 cm ± S.D. 0.37 cm on right and on right and 2.16 cm ± S.D. 0.40 cm on left lateral radiographs ; these results were not significantly different(P=0.79). In cases of collapse, the mean value of the distance was 0.43 cm ± S.D. 0.99 cm in upper lobe collapse and 3.56 cm ± S.D. 0.72 cm in lower lobe collapse, results which were significantly different from those of normal cases(p<0.01). In eight cases(73%) of left upper lobe collapse, the distance was less than 1 cm and in 10 cases(77%) of left lower lobe collapse, the distance was more than 3 cm. The distance between both upper lobe bronchi varies markedly in case of lobar collapse. A distance of less than 1 cm suggests collapse of the left upper lobe and a distance more than 3 cm suggests collapse of the left lower lobe

  2. Constraining the sedimentology and stratigraphy of submarine intraslope lobe deposits using exhumed examples from the Karoo Basin, South Africa

    Science.gov (United States)

    Spychala, Y. T.; Hodgson, D. M.; Flint, S. S.; Mountney, N. P.

    2015-06-01

    Intraslope lobe deposits provide a process record of the infill of accommodation on submarine slopes and their recognition enables the accurate reconstruction of the stratigraphic evolution of submarine slope systems. Extensive exposures of discrete sand-prone packages in Units D/E and E, Fort Brown Formation, Karoo Basin, South Africa, permit analysis of the sedimentology and stacking patterns of three intraslope lobe complexes and their palaeogeographic reconstruction via bed-scale analysis and physical correlation of key stratal surfaces. The sand-prone packages comprise tabular, aggradationally to slightly compensationally stacked lobe deposits with constituent facies associations that can be attributed to lobe axis, lobe off-axis, lobe-fringe and distal lobe-fringe environments. Locally, intraslope lobe deposits are incised by low aspect ratio channels that mark basinward progradation of the deepwater system. The origin of accommodation on the slope for lobe deposition is interpreted to be due to differential compaction or healing of scars from mass wasting processes. The stacking patterns and sedimentary facies arrangement identified in this study are distinct from those of more commonly recognized basin-floor lobe deposits, thereby enabling the establishment of recognition criteria for intraslope lobe deposits in other less well exposed and studied fine-grained systems. Compared to basin floor lobes, intraslope lobes are smaller in volume, influenced by higher degrees of confinement, and tend to show aggradational stacking patterns.

  3. Lesser sac hematoma as a sign of rupture of hepatocellular carcinoma in the caudate lobe

    International Nuclear Information System (INIS)

    Iwasaki, Yoshie; Tani, Ichiro; Nakajima, Yasuo; Ishikawa, Tohru; Umeda, Satoshi; Kusano, Shoichi

    2001-01-01

    The purpose of this study was to evaluate the CT findings of rupture of hepatocellular carcinoma (HCC) in the caudate lobe of the liver. The CT scans of five cases of rupture of HCC in the caudate lobe of the liver were retrospectively reviewed and correlated with clinical records. All cases showed exophytic tumors in the caudate lobe of the liver and high-attenuation hematomas in the lesser sac on CT. A lesser sac hematoma may be a sentinel clot sign of rupture of HCC in the caudate lobe. (orig.)

  4. ON THE ORIGIN OF FANAROFF-RILEY CLASSIFICATION OF RADIO GALAXIES: DECELERATION OF SUPERSONIC RADIO LOBES

    International Nuclear Information System (INIS)

    Kawakatu, Nozomu; Kino, Motoki; Nagai, Hiroshi

    2009-01-01

    We argue that the origin of 'FRI/FRII dichotomy' - the division between Fanaroff-Riley class I (FRI) with subsonic lobes and class II (FRII) radio sources with supersonic lobes is sharp in the radio-optical luminosity plane (Owen-White diagram) - can be explained by the deceleration of advancing radio lobes. The deceleration is caused by the growth of the effective cross-sectional area of radio lobes. We derive the condition in which an initially supersonic lobe turns into a subsonic lobe, combining the ram pressure equilibrium between the hot spots and the ambient medium with the relation between 'the hot spot radius' and 'the linear size of radio sources' obtained from the radio observations. We find that the dividing line between the supersonic lobes and subsonic ones is determined by the ratio of the jet power L j to the number density of the ambient matter at the core radius of the host galaxy n-bar a . It is also found that the maximal ratio of (L j ,n-bar a ) exists and its value resides in (L j ,n-bar a ) max ∼10 44-47 er s -1 cm 3 , taking into account considerable uncertainties. This suggests that the maximal value (L j ,n-bar a ) max separates between FRIs and FRIIs.

  5. Upper motor neuron predominant degeneration with frontal and temporal lobe atrophy.

    Science.gov (United States)

    Konagaya, M; Sakai, M; Matsuoka, Y; Konagaya, Y; Hashizume, Y

    1998-11-01

    The autopsy findings of a 78-year-old man mimicking primary lateral sclerosis (PLS) are reported. He showed slowly progressive spasticity, pseudobulbar palsy and character change, and died 32 months after the onset of symptoms. Autopsy revealed severe atrophy of the frontal and temporal lobes, remarkable neuronal loss and gliosis in the precentral gyrus, left temporal lobe pole and amygdala, mild degeneration of the Ammon's horn, degeneration of the corticospinal tract, and very mild involvement of the lower motor neurons. The anterior horn cells only occasionally demonstrated Bunina body by cystatin-C staining, and skein-like inclusions by ubiquitin staining. This is a peculiar case with concomitant involvement in the motor cortex and temporal lobe in motor neuron disease predominantly affecting the upper motor neuron.

  6. Clinical observations on attention-deficit hyperactivity disorder (ADHD) in children with frontal lobe epilepsy.

    Science.gov (United States)

    Zhang, Dong-Qing; Li, Fu-Hai; Zhu, Xiao-Bo; Sun, Ruo-Peng

    2014-01-01

    The objective was to investigate the prevalence of attention-deficit hyperactivity disorder (ADHD) in children with frontal lobe epilepsy and related factors. The medical records of 190 children diagnosed with frontal lobe epilepsy at Qilu Hospital of Shandong University between 2006 and 2011 were retrospectively collected, and a follow-up analysis of the prevalence of ADHD in these children was conducted. Of the 161 children with an effective follow-up, 59.0% (95/161) with frontal lobe epilepsy suffered from ADHD as well. Analysis of epilepsy and ADHD-related factors indicated that the incidence of ADHD was 89.4% (76/85) in children with abnormal electroencephalogram (EEG) discharges on the most recent EEG, which was significantly higher than the ADHD incidence of 25% (19/76) in children with normal readings on the most recent EEG (P Children with frontal lobe epilepsy have a high incidence of ADHD. Sustained abnormal discharge on the electroencephalogram is associated with increased comorbidity of ADHD with frontal lobe epilepsy.

  7. Sulcal and gyral anatomy of the basal occipital-temporal lobe.

    Science.gov (United States)

    Chau, Anthony Minh Tien; Stewart, Fiona; Gragnaniello, Cristian

    2014-12-01

    The sulcal and gyral anatomy of the basal occipital-temporal lobe is highly variable and detailed descriptions of this region are limited and often inconsistent. The aim of this study was to describe the salient features of the sulcal and gyral anatomy of the basal occipital-temporal lobe. We studied the sulcal and gyral patterns of 30 formalin-fixed cerebral hemispheres. The major landmarks are the collateral sulcus (separated into the rhinal, proper, and caudal segments) and occipitotemporal sulcus (often interrupted), which were always present in this study. The bifurcation of the caudal collateral sulcus is a useful landmark. In relation to these sulci, we have described the surface anatomy and nominated landmarks of the medial (parahippocampal and lingual) and lateral (fusiform) occipitotemporal gyri. Understanding of the sulcal and gyral patterns of the basal occipital-temporal lobe may provide valuable information in its radiological and intraoperative interpretation.

  8. Late bilateral temporal lobe necrosis after conventional radiotherapy. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshi, Michio; Hayashi, Toshiyuki; Kagami, Hiroshi; Murase, Ikurou; Nakatsukasa, Masashi [Saiseikai Utsunomiya Hospital (Japan)

    2003-04-01

    A 63-year-old woman presented with radionecrosis in the bilateral temporal lobes manifesting as dementia about 30 years after undergoing conventional radiotherapy for pituitary adenoma. Computed tomography and magnetic resonance (MR) imaging showed edema and cystic lesions in both temporal lobes. The mass in the left temporal lobe was excised. MR imaging 12 days after surgery showed reduced edema. Her dementia had improved. Radionecrosis usually occurs between several months and a few years after radiotherapy. The incidence of radionecrosis is estimated as 5%, but may be higher with longer follow-up periods. Clinical reports have suggested that larger total doses of radiation are associated with earlier onset of delayed necrosis and the fractional dose is the most significant factor causing cerebral radionecrosis. Radionecrosis can occur long after conventional radiotherapy or stereotactic radiosurgery using a linac-based system or a gamma knife unit. (author)

  9. Atypical language representation in children with intractable temporal lobe epilepsy.

    Science.gov (United States)

    Maulisova, Alice; Korman, Brandon; Rey, Gustavo; Bernal, Byron; Duchowny, Michael; Niederlova, Marketa; Krsek, Pavel; Novak, Vilem

    2016-05-01

    This study evaluated language organization in children with intractable epilepsy caused by temporal lobe focal cortical dysplasia (FCD) alone or dual pathology (temporal lobe FCD and hippocampal sclerosis, HS). We analyzed clinical, neurological, fMRI, neuropsychological, and histopathologic data in 46 pediatric patients with temporal lobe lesions who underwent excisional epilepsy surgery. The frequency of atypical language representation was similar in both groups, but children with dual pathology were more likely to be left-handed. Atypical receptive language cortex correlated with lower intellectual capacity, verbal abstract conceptualization, receptive language abilities, verbal working memory, and a history of status epilepticus but did not correlate with higher seizure frequency or early seizure onset. Histopathologic substrate had only a minor influence on neuropsychological status. Greater verbal comprehension deficits were noted in children with atypical receptive language representation, a risk factor for cognitive morbidity. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. A case of luftsichel sign for left upper lobe collapse

    Directory of Open Access Journals (Sweden)

    Erden Erol Ünlüer

    2015-01-01

    Full Text Available The differential diagnosis of dyspnea in Emergency Department (ED patients is broad and atelectasis is one of the differentials among these. We present a 29-year-old women presented to our ED for evaluation of shortness of breath. On her chest examination, air entry and breath sounds were diminished on the left side but normal on the right. A posteroanterior chest radiograph showed radioluscent area in the upper zone of the left lung, around the aortic arch and also hyperdens area neighbouring this, like covered by a veil. Luftsichel sign together with this hiperdensity were consistent with the diagnose of left lung upper lobe collapse. The Luftsichel sign represents the hyperexpanded superior segment of the left lower lobe interposed between the atelectatic left upper lobe and aortic arch. Patient was discharged to home with chest physiotherapy and breathing exercises together with analgesic prescreption.

  11. Flexible receiver adapter and secondary bagger support frame analysis for 241AP102 mixer pump removal

    International Nuclear Information System (INIS)

    Axup, M.D.; Egger, J.

    1995-01-01

    As part of the Grout Process startup, the 241AP102 Mixer Pump, failed in 1993, is scheduled to be removed. A structural analysis was performed on two components to be used in the bagging process for the failed pump. The loading criteria was based on a worst case accident of the entire pump weight (including a 50% impact load) being applied over a small localized area. The results show that the design of each structure is adequate to protect against failure, i.e., yield

  12. Asymmetry of medial and lateral temporal regional glucose metabolism in temporal lobe epilepsy by F-18-FDG PET

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Yeo, Jeong Seok; Song, Ho Cheon; Lee, Sang Kun; Kim, Hyun Jip; Chung, June Key; Lee, Myung Chul

    1999-01-01

    We investigated the difference of glucose metabolism of medial and lateral temporal lobes of patients with temporal lobe epilepsy (TLE) utilizing quantitative comparison of regional metabolic activities using asymmetric index. We studied 19 pathologically proven mesial TLE and 25 lateral TLE patients. Lateral TLE patients were either normal on magnetic resonance imaging (cryptogenic: n=14) or had structural lesions (lesional: n=11). Asymmetric index (ASI) was calculated as [(ipsilateral contralateral)/(ipsilateral + contralateral )]x200. ASI of medial and lateral lobes of mesial TLE was decreased (-16.4±8.3 and -12.7± 5.5, respectively). In cryptogenic lateral TLE, ASI of lateral temporal lobe was decreased (-11.8± 4.7), whereas that of medial temporal lobe was not decreased (-4.6±6.3). ASI of medial lobe of lesional lateral TLE was -7.3±9.1, which was significantly different from that of mesial TLE (p<0.05). Patients with lesional lateral TLE had evident metabolic defects or decrease (ASI: -22±10.5) in lateral temporal lobe. While we could not find the difference of metabolic activity in lateral temporal lobes between cryptogenic lateral TLE and mesial TLE patients, the difference of metabolic activity was significant in medial temporal lobes which was revealed by ASI quantitation. Asymmetric decrease of metabolic activity in both medial and lateral temporal lobes indicates medial temporal epilepsy. Symmetry of metabolic activity in medial temporal lobe combined with asymmetry of that in lateral temporal lobe may give hints that the epileptogenic zone is lateral

  13. Detection of non-thermal X-ray emission in the lobes and jets of Cygnus A

    Science.gov (United States)

    de Vries, M. N.; Wise, M. W.; Huppenkothen, D.; Nulsen, P. E. J.; Snios, B.; Hardcastle, M. J.; Birkinshaw, M.; Worrall, D. M.; Duffy, R. T.; McNamara, B. R.

    2018-06-01

    We present a spectral analysis of the lobes and X-ray jets of Cygnus A, using more than 2 Ms of Chandra observations. The X-ray jets are misaligned with the radio jets and significantly wider. We detect non-thermal emission components in both lobes and jets. For the eastern lobe and jet, we find 1 keV flux densities of 71_{-10}^{+10} nJy and 24_{-4}^{+4} nJy, and photon indices of 1.72_{-0.03}^{+0.03} and 1.64_{-0.04}^{+0.04} respectively. For the western lobe and jet, we find flux densities of 50_{-13}^{+12} nJy and 13_{-5}^{+5} nJy, and photon indices of 1.97_{-0.10}^{+0.23} and 1.86_{-0.12}^{+0.18} respectively. Using these results, we modeled the electron energy distributions of the lobes as broken power laws with age breaks. We find that a significant population of non-radiating particles is required to account for the total pressure of the eastern lobe. In the western lobe, no such population is required and the low energy cutoff to the electron distribution there needs to be raised to obtain pressures consistent with observations. This discrepancy is a consequence of the differing X-ray photon indices, which may indicate that the turnover in the inverse-Compton spectrum of the western lobe is at lower energies than in the eastern lobe. We modeled the emission from both jets as inverse-Compton emission. There is a narrow region of parameter space for which the X-ray jet can be a relic of an earlier active phase, although lack of knowledge about the jet's electron distribution and particle content makes the modelling uncertain.

  14. Brain-responsive neurostimulation in patients with medically intractable mesial temporal lobe epilepsy.

    Science.gov (United States)

    Geller, Eric B; Skarpaas, Tara L; Gross, Robert E; Goodman, Robert R; Barkley, Gregory L; Bazil, Carl W; Berg, Michael J; Bergey, Gregory K; Cash, Sydney S; Cole, Andrew J; Duckrow, Robert B; Edwards, Jonathan C; Eisenschenk, Stephan; Fessler, James; Fountain, Nathan B; Goldman, Alicia M; Gwinn, Ryder P; Heck, Christianne; Herekar, Aamar; Hirsch, Lawrence J; Jobst, Barbara C; King-Stephens, David; Labar, Douglas R; Leiphart, James W; Marsh, W Richard; Meador, Kimford J; Mizrahi, Eli M; Murro, Anthony M; Nair, Dileep R; Noe, Katherine H; Park, Yong D; Rutecki, Paul A; Salanova, Vicenta; Sheth, Raj D; Shields, Donald C; Skidmore, Christopher; Smith, Michael C; Spencer, David C; Srinivasan, Shraddha; Tatum, William; Van Ness, Paul C; Vossler, David G; Wharen, Robert E; Worrell, Gregory A; Yoshor, Daniel; Zimmerman, Richard S; Cicora, Kathy; Sun, Felice T; Morrell, Martha J

    2017-06-01

    Evaluate the seizure-reduction response and safety of mesial temporal lobe (MTL) brain-responsive stimulation in adults with medically intractable partial-onset seizures of mesial temporal lobe origin. Subjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. There were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy-six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow-up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty-nine percent of subjects experienced at least one seizure-free period of 6 months or longer, and 15% experienced at least one seizure-free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device-related adverse event was soft tissue implant-site infection (overall rate, including events categorized as device-related, uncertain, or not device-related: 0.03 per implant year, which is not greater than with other neurostimulation devices). Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for

  15. Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Joo, Yang Goo; Lee, Sang Doe; Son, Eun Ik; Lee, Young Hwan

    1994-01-01

    Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients (8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCRF SPECT was done in all 18 patients with intravenous injection of 740 MRq 99 m T c-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification (four part classification recommended at the first Palm Desert conference). rCRF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/ 18 (72.2%), contralateral temporal lobe hypoperfusion in 2/18 (11.1%) and showed no definite abnormality in 3/18 (16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13 (61.5%), such as hippocampal atrophy (7/13), asymmetric temporal horn (6/13), anterior temporal lobe atrophy (1/13), increased signal intensity from hippocampus (1/13) and calcific density (1/13), and no abnormal finding was noted in 5/13 (38.5%), There was no false positive findings and the positive predictive value of MRI was 100%, Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18 (83.3%), and class II in 2/18 (11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical out.come was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  16. Interfacial effects in a multistage mixer-settler operation

    International Nuclear Information System (INIS)

    Jiinshiung Horng; Daluh Lu; Yingchu Hoh

    1988-01-01

    A pilot-scale mixer-settler with twenty-one stages was used to investigate the interfacial tension change during extraction cycle for the complicated system: NdCl 3 -SmCl 3 -EuCl 3 -GdCl 3 -TbCl 3 -DyCl 3 -HCl- 1 M D2EHPA-kerosene. Interfacial tension, total rare earth (TRE) concentrations in both phases, aqueous acidities, and organic entrainment in the raffinate, etc., were measured for each stage. Murphree stage efficiencies based on organic phase were calculated and related to the interfacial tension profiles. In general, the lower the interfacial tension, the higher the stage efficiency observed. For the extraction section, the stage efficiency ranged from 80% - 100%, but for stripping (including scrubbing) section, it varied from 100% - 15%. For high acidic stripping agent, 5 M HCl, the relatively lower stage efficiency might be due to the protonation of the acidic extractant, therefore the interfacial resistance increased significantly. From the information of stage efficiency, mass transfer direction, and interfacial tension versus solute concentration etc., the Marangoni effect could be used to explain the interfacial phenomena of this complicated extraction system. The results of real stream tests in this investigation will be useful in future plant design. (author)

  17. The anterior temporal lobes support residual comprehension in Wernicke's aphasia.

    Science.gov (United States)

    Robson, Holly; Zahn, Roland; Keidel, James L; Binney, Richard J; Sage, Karen; Lambon Ralph, Matthew A

    2014-03-01

    Wernicke's aphasia occurs after a stroke to classical language comprehension regions in the left temporoparietal cortex. Consequently, auditory-verbal comprehension is significantly impaired in Wernicke's aphasia but the capacity to comprehend visually presented materials (written words and pictures) is partially spared. This study used functional magnetic resonance imaging to investigate the neural basis of written word and picture semantic processing in Wernicke's aphasia, with the wider aim of examining how the semantic system is altered after damage to the classical comprehension regions. Twelve participants with chronic Wernicke's aphasia and 12 control participants performed semantic animate-inanimate judgements and a visual height judgement baseline task. Whole brain and region of interest analysis in Wernicke's aphasia and control participants found that semantic judgements were underpinned by activation in the ventral and anterior temporal lobes bilaterally. The Wernicke's aphasia group displayed an 'over-activation' in comparison with control participants, indicating that anterior temporal lobe regions become increasingly influential following reduction in posterior semantic resources. Semantic processing of written words in Wernicke's aphasia was additionally supported by recruitment of the right anterior superior temporal lobe, a region previously associated with recovery from auditory-verbal comprehension impairments. Overall, the results provide support for models in which the anterior temporal lobes are crucial for multimodal semantic processing and that these regions may be accessed without support from classic posterior comprehension regions.

  18. Complications after mesial temporal lobe surgery via inferiortemporal gyrus approach.

    Science.gov (United States)

    Vale, Fernando L; Reintjes, Stephen; Garcia, Hermes G

    2013-06-01

    The purpose of this study was to identify the complications associated with the inferior temporal gyrus approach to anterior mesial temporal lobe resection for temporal lobe epilepsy. This retrospective study examined complications experienced by 483 patients during the 3 months after surgery. All surgeries were performed during 1998-2012 by the senior author (F.L.V.). A total of 13 complications (2.7%) were reported. Complications were 8 delayed subdural hematomas (1.6%), 2 superficial wound infections (0.4%), 1 delayed intracranial hemorrhage (0.2%), 1 small lacunar stroke (0.2%), and 1 transient frontalis nerve palsy (0.2%). Three patients with subdural hematoma (0.6%) required readmission and surgical intervention. One patient (0.2%) with delayed intracranial hemorrhage required readmission to the neuroscience intensive care unit for observation. No deaths or severe neurological impairments were reported. Among the 8 patients with subdural hematoma, 7 were older than 40 years (87.5%); however, this finding was not statistically significant (p = 0.198). The inferior temporal gyrus approach to mesial temporal lobe resection is a safe and effective method for treating temporal lobe epilepsy. Morbidity and mortality rates associated with this procedure are lower than those associated with other neurosurgical procedures. The finding that surgical complications seem to be more common among older patients emphasizes the need for early surgical referral of patients with medically refractory epilepsy.

  19. Developmental trajectories of the fronto-temporal lobes from infancy to early adulthood in healthy individuals.

    Science.gov (United States)

    Tanaka, Chiaki; Matsui, Mie; Uematsu, Akiko; Noguchi, Kyo; Miyawaki, Toshio

    2012-01-01

    Brain development during early life in healthy individuals is rapid and dynamic, indicating that this period plays a very important role in neural and functional development. The frontal and temporal lobes are known to play a particularly important role in cognition. The study of healthy frontal and temporal lobe development in children is therefore of considerable importance. A better understanding of how these brain regions develop could also aid in the diagnosis and treatment of neurodevelopmental disorders. Some developmental studies have used magnetic resonance imaging (MRI) to examine infant brains, but it remains the case that relatively little is known about cortical brain development in the first few years of life. In the present study we examined whole brain, temporal lobe and frontal lobe developmental trajectories from infancy to early adulthood in healthy individuals, considering gender and brain hemisphere differences. We performed a cross-sectional, longitudinal morphometric MRI study of 114 healthy individuals (54 females and 60 males) aged 1 month to 25 years old (mean age ± SD 8.8 ± 6.9). We measured whole brain, temporal and frontal lobe gray matter (GM)/white matter (WM) volumes, following previously used protocols. There were significant non-linear age-related volume changes in all regions. Peak ages of whole brain, temporal lobe and frontal lobe development occurred around pre-adolescence (9-12 years old). GM volumes for all regions increased significantly as a function of age. Peak age was nevertheless lobe specific, with a pattern of earlier peak ages for females in both temporal and frontal lobes. Growth change in whole brain GM volume was larger in males than in females. However, GM volume growth changes for the temporal and frontal lobes showed a somewhat different pattern. GM volume for both temporal and frontal lobes showed a greater increase in females until around 5-6 years old, at which point this tendency reversed (GM volume

  20. Occipital lobe infarctions are different

    OpenAIRE

    Naess, Halvor; Waje-Andreassen, Ulrikke; Thomassen, Lars

    2007-01-01

    Halvor Naess, Ulrikke Waje-Andreassen, Lars ThomassenDepartment of Neurology, Haukeland University Hospital, University of Bergen, N-5021 Bergen, NorwayObjectives: We hypothesized that occipital lobe infarctions differ from infarctions in other locations as to etiology, risk factors and prognosis among young adults.Methods: Location, etiology, risk factors and long-term outcome were evaluated among all young adults 15–49 years suffering from cerebral infarction in Hordaland County, Norw...

  1. Temporal lobe surgery in childhood and neuroanatomical predictors of long-term declarative memory outcome

    Science.gov (United States)

    Skirrow, Caroline; Cross, J. Helen; Harrison, Sue; Cormack, Francesca; Harkness, William; Coleman, Rosie; Meierotto, Ellen; Gaiottino, Johanna; Vargha-Khadem, Faraneh

    2015-01-01

    The temporal lobes play a prominent role in declarative memory function, including episodic memory (memory for events) and semantic memory (memory for facts and concepts). Surgical resection for medication-resistant and well-localized temporal lobe epilepsy has good prognosis for seizure freedom, but is linked to memory difficulties in adults, especially when the removal is on the left side. Children may benefit most from surgery, because brain plasticity may facilitate post-surgical reorganization, and seizure cessation may promote cognitive development. However, the long-term impact of this intervention in children is not known. We examined memory function in 53 children (25 males, 28 females) who were evaluated for epilepsy surgery: 42 underwent unilateral temporal lobe resections (25 left, 17 right, mean age at surgery 13.8 years), 11 were treated only pharmacologically. Average follow-up was 9 years (range 5–15). Post-surgical change in visual and verbal episodic memory, and semantic memory at follow-up were examined. Pre- and post-surgical T1-weighted MRI brain scans were analysed to extract hippocampal and resection volumes, and evaluate post-surgical temporal lobe integrity. Language lateralization indices were derived from functional magnetic resonance imaging. There were no significant pre- to postoperative decrements in memory associated with surgery. In contrast, gains in verbal episodic memory were seen after right temporal lobe surgery, and visual episodic memory improved after left temporal lobe surgery, indicating a functional release in the unoperated temporal lobe after seizure reduction or cessation. Pre- to post-surgical change in memory function was not associated with any indices of brain structure derived from MRI. However, better verbal memory at follow-up was linked to greater post-surgical residual hippocampal volumes, most robustly in left surgical participants. Better semantic memory at follow-up was associated with smaller resection

  2. First reported case of unilateral Graves' disease in the left lobe of a bilobar thyroid gland.

    Science.gov (United States)

    Chen, Louis C; Green, Jennifer B

    2011-06-01

    Unilateral Graves' disease is a rare disease variant that can occur in a bilobar thyroid gland. We report the first documented case of unilateral Graves' disease in the left lobe of a bilobar thyroid gland and review the pertinent literature. A 48-year-old man presented in June 2010 with thyrotoxicosis. I-131 radioisotope uptake was elevated at 33.4%, and scintigraphy revealed that uptake of the radioisotope was uniformly increased in the left lobe of the thyroid gland. Ultrasonography of the thyroid gland revealed a non-nodular, enlarged, and heterogeneous left lobe; Doppler investigation of the lobe showed hypervascularity classically seen in Graves' disease. The right lobe of the thyroid, on the other hand, appeared homogeneous and hypovascular on ultrasonography. Thyroid-stimulating immunoglobulin was significantly elevated at 191% (reference range disease was the most likely diagnosis. As has occasionally been described in the literature, unilateral involvement of the thyroid gland is a rare presentation of Graves' disease. Pre-existing functional or structural differences (either congenital or acquired) between the two lobes may contribute to this rare presentation. To our knowledge, this is the first reported case of unilateral Graves' disease presenting in the left lobe of a bilobar thyroid gland. Although the pathophysiology of unilateral Graves's disease has not been clearly elucidated, clinicians should be aware that Graves' disease can present unilaterally in either lobe of the thyroid gland.

  3. Cognitive Functioning in Temporal Lobe Epilepsy: A BOLD-fMRI Study.

    Science.gov (United States)

    Guo, Lili; Bai, Genji; Zhang, Hui; Lu, Daoyan; Zheng, Jiyong; Xu, Gang

    2017-12-01

    We aimed to analyze the association between resting-state functional magnetic resonance imaging (re-fMRI) and cognitive function (including language, executive, and memory functions) in temporal lobe epilepsy (TLE) patients, which will help to explore the mechanism of brain function in patients. 15 TLE patients and 15 non-TLE patients were recruited. All subjects underwent neuropsychological testing and memory functional evaluation. Changes in verbal intelligence quotient (VIQ), performance intelligence quotient (PIQ), full intelligence quotient (FIQ), and memory quotient (MQ) were compared between two groups. Re-fMRI data were also collected from two groups to evaluate these changes. Each individual score of neuropsychological testing and memory functional evaluation were higher in control group, which was statistically different (all P temporal gyrus back, right superior temporal gyrus, left cerebellum, left angular gyrus, left wedge anterior lobe, and left central back; while the negatively activated brain regions were left prefrontal, right cerebellum, right corner back, and right anterior cingulate gyrus. During the language task, the activated brain regions of the TLE patients were right prefrontal lobe, the lateral temporal gyri, the left cerebellum, left cornu laterale gyrus, left precuneus, and the left postcentral gyrus, whereas the negatively activated brain areas were the left prefrontal cortex, the right cerebellum, right cornu laterale gyrus, and the right anterior cingulate gyrus. During the executive task, epilepsy patients showed activation difference in right prefrontal and right frontal lobe and right brain, left superior temporal gyrus, and right cerebellum anterior lobe compared with the control group; no negatively activated differences in brain areas. During the memory task, the difference lay in bilateral anterior cingulate gyrus and bilateral wedge anterior lobe while the negatively activated brain areas were the left inferior frontal

  4. Gene expression profile in temporal lobe epilepsy

    NARCIS (Netherlands)

    Aronica, Eleonora; Gorter, Jan A.

    2007-01-01

    Epilepsy is one of the most common neurological disorders. Temporal lobe epilepsy (TLE) represents the most frequent epilepsy syndrome in adult patients with resistance to pharmacological treatment. In TLE, the origin of seizure activity typically involves the hippocampal formation, which displays

  5. Gene expression profile in temporal lobe epilepsy.

    NARCIS (Netherlands)

    Aronica, E.M.A.; Gorter, J.A.

    2007-01-01

    Epilepsy is one of the most common neurological disorders. Temporal lobe epilepsy (TLE) represents the most frequent epilepsy syndrome in adult patients with resistance to pharmacological treatment. In TLE, the origin of seizure activity typically involves the hippocampal formation, which displays

  6. Weighing the value of memory loss in the surgical evaluation of left temporal lobe epilepsy: a decision analysis.

    Science.gov (United States)

    Akama-Garren, Elliot H; Bianchi, Matt T; Leveroni, Catherine; Cole, Andrew J; Cash, Sydney S; Westover, M Brandon

    2014-11-01

    Anterior temporal lobectomy is curative for many patients with disabling medically refractory temporal lobe epilepsy, but carries an inherent risk of disabling verbal memory loss. Although accurate prediction of iatrogenic memory loss is becoming increasingly possible, it remains unclear how much weight such predictions should have in surgical decision making. Here we aim to create a framework that facilitates a systematic and integrated assessment of the relative risks and benefits of surgery versus medical management for patients with left temporal lobe epilepsy. We constructed a Markov decision model to evaluate the probabilistic outcomes and associated health utilities associated with choosing to undergo a left anterior temporal lobectomy versus continuing with medical management for patients with medically refractory left temporal lobe epilepsy. Three base-cases were considered, representing a spectrum of surgical candidates encountered in practice, with varying degrees of epilepsy-related disability and potential for decreased quality of life in response to post-surgical verbal memory deficits. For patients with moderately severe seizures and moderate risk of verbal memory loss, medical management was the preferred decision, with increased quality-adjusted life expectancy. However, the preferred choice was sensitive to clinically meaningful changes in several parameters, including quality of life impact of verbal memory decline, quality of life with seizures, mortality rate with medical management, probability of remission following surgery, and probability of remission with medical management. Our decision model suggests that for patients with left temporal lobe epilepsy, quantitative assessment of risk and benefit should guide recommendation of therapy. In particular, risk for and potential impact of verbal memory decline should be carefully weighed against the degree of disability conferred by continued seizures on a patient-by-patient basis. Wiley

  7. Supercritical flows and their control on the architecture and facies of small-radius sand-rich fan lobes

    Science.gov (United States)

    Postma, George; Kleverlaan, Kick

    2018-02-01

    New insights into flow characteristics of supercritical, high-density turbidity currents initiated renewed interest in a sand-rich lobe complex near the hamlet of Mizala in the Sorbas Basin (Tortonian, SE Spain). The field study was done using drone-made images taken along bed strike in combination with physical tracing of bounding surfaces and section logging. The studied lobe systems show a consistent built-up of lobe elements of 1.5-2.0 m thick, which form the building 'blocks' of the lobe system. The stacking of lobe elements shows lateral shift and compensational relief infill. The new model outlined in this paper highlights three stages of fan lobe development: I. an early aggradational stage with lobe elements characterized by antidune and traction-carpet bedforms and burrowed mud intervals (here called 'distal fan' deposits); II. a progradational stage, where the distal fan deposits are truncated by lobe elements of amalgamated sandy to gravelly units characterized by cyclic step bedform facies (designated as 'supra fan' deposits). The supra fan is much more channelized and scoured and of higher flow energy than the distal-fan. Aggradation of the supra-fan is terminated by a 'pappy' pebbly sandstone and by substrate liquefaction, 'pappy' referring to a typical, porridge-like texture indicating rapid deposition under conditions of little-to-no shear. The facies-bounded termination of the supra-fan is here related to its maximum elevation, causing the lobe-feeding supercritical flow to choke and to expand upwards by a strong hydraulic jump at the channel outlet; III. a backfilling stage, characterized by backfilling of the remaining relief with progressively thinning and fining of turbidite beds and eventually with mud. The three-stage development for fan-lobe building is deducted from reoccurring architectural and facies characteristics in three successive fan-lobes. The validity of using experimental, supercritical-flow fan studies for understanding the

  8. Occipital lobe seizures and epilepsies.

    Science.gov (United States)

    Adcock, Jane E; Panayiotopoulos, Chrysostomos P

    2012-10-01

    Occipital lobe epilepsies (OLEs) manifest with occipital seizures from an epileptic focus within the occipital lobes. Ictal clinical symptoms are mainly visual and oculomotor. Elementary visual hallucinations are common and characteristic. Postictal headache occurs in more than half of patients (epilepsy-migraine sequence). Electroencephalography (EEG) is of significant diagnostic value, but certain limitations should be recognized. Occipital spikes and/or occipital paroxysms either spontaneous or photically induced are the main interictal EEG abnormalities in idiopathic OLE. However, occipital epileptiform abnormalities may also occur without clinical relationship to seizures particularly in children. In cryptogenic/symptomatic OLE, unilateral posterior EEG slowing is more common than occipital spikes. In neurosurgical series of symptomatic OLE, interictal EEG abnormalities are rarely strictly occipital. The most common localization is in the posterior temporal regions and less than one-fifth show occipital spikes. In photosensitive OLE, intermittent photic stimulation elicits (1) spikes/polyspikes confined in the occipital regions or (2) generalized spikes/polyspikes with posterior emphasis. In ictal EEG, a well-localized unifocal rhythmic ictal discharge during occipital seizures is infrequent. A bioccipital field spread to the temporal regions is common. Frequency, severity, and response to treatment vary considerably from good to intractable and progressive mainly depending on underlying causes.

  9. Frontal lobe epilepsy may present as myoclonic seizures.

    Science.gov (United States)

    Cho, Yong Won; Yi, Sang Doe; Motamedi, Gholam K

    2010-04-01

    We describe a patient with seizures arising from right anterior-inferior frontal lobe presenting as myoclonic epilepsy. A 19-year-old man had experienced frequent paroxysmal bilateral myoclonic jerks involving his upper arms, shoulders, neck, and upper trunk since the age of 10. His baseline EEG showed intermittent right frontal spikes, and his ictal EEG showed rhythmic sharp theta discharges in the same area. MRI revealed cortical dysplasia in the right inferior frontal gyrus, and ictal-interictal SPECT analysis by SPM showed increased signal abnormality in this region. Diffusion tensor imaging (DTI) showed defects in fasciculi in the same area. These findings suggest that frontal lobe epilepsy should be considered in some patients with myoclonic seizures. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  10. The relationship of medial temporal lobe epilepsy with the declarative memory system

    Directory of Open Access Journals (Sweden)

    Halász Péter

    2016-12-01

    Full Text Available Introduction. Medial temporal lobe of epilepsy (MTLE is considered as local/regional epilepsy. However, as was discussed in Part I of this review (Halász, 2016a there is more evidence regarding the involvement of both temporal lobes so as to consider MTLE as one of the typical bilateral system epilepsies.

  11. Assessment of anosognosia in persons with frontal lobe damage: clinical utility of the Mayo-Portland Adaptability Inventory (MPAI).

    Science.gov (United States)

    Murrey, G J; Hale, F M; Williams, J D

    2005-08-10

    To determine if the Mayo-Portland Adaptability Inventory (MPAI) demonstrates clinical utility in differentiating between persons with severe TBI and frontal lobe damage/anosognosia and persons with mild TBI and no frontal lobe damage. Forty-three persons with TBI and documented frontal lobe damage (mean age = 34; mean time since injury = 5.2 years) and 69 persons with mild TBI and no frontal lobe damage (mean age = 34.3; mean time since injury = 4.8 4.8 years). MPAI. Total inventory and select sub-category difference scores were significantly greater in the frontal lobe group than in the non-frontal lobe group. However, as expected, there was no significant difference between the two groups on the mobility sub-category difference scores. The MPAI appears to be potentially clinically useful in assessing for frontal lobe damage and associated anosognosia in patients with TBI.

  12. Brain mapping of epileptic activity in a case of idiopathic occipital lobe epilepsy (Panayiotopoulos syndrome).

    Science.gov (United States)

    Leal, Alberto J R; Nunes, Sofia; Martins, António; Secca, Mário Forjaz; Jordão, Constança

    2007-06-01

    The Panayiotopoulos type of occipital lobe epilepsy has generated great interest, but the particular brain areas involved in the peculiar seizure manifestations have not been established. We studied a patient with the syndrome, using high-resolution EEG and simultaneous EEG and functional magnetic resonance imaging (fMRI). Resolution of the scalp EEG was improved using a realistic spline Laplacian algorithm, and produced a complex distribution of current sinks and sources over the occipital lobe. The spike-related blood oxygen level dependent (BOLD) effect was multifocal, with clusters in lateral and inferior occipital lobe and lateral and anterior temporal lobe. We also performed regional dipole seeding in BOLD clusters to determine their relative contribution to generation of scalp spikes. The integrated model of the neurophysiologic and vascular data strongly suggests that the epileptic activity originates in the lateral occipital area, spreading to the occipital pole and lateral temporal lobe.

  13. CT evaluation of decrease in attenuation in the superior segment of the left lower lobe

    International Nuclear Information System (INIS)

    Inaoka, Tsutomu; Takahashi, Koji; Ono, Hidetoshi

    2003-01-01

    We occasionally see decrease in attenuation in the superior segment of the left lower lobe on normal chest CT and notice that this finding could be seen in elder population. Then, we assessed the frequency, age distribution and cause of decrease in attenuation in the superior segment of the left lower lobe. Chest CT scans of 246 patients without lung or cardiac disorders were retrospectively reviewed. Segmental low attenuation area in the superior segment of the left lower lobe was identified in 12 patients (4.9%), which were 65-92 years old with mean age of 77.2 years old. In all of them, chest CT demonstrated that the tortuous descending aorta compressed directly the superior segmental bronchus of the left lower lobe. It is concluded that the lateral tortuousity of the descending aorta could cause decrease in attenuation in the superior segment of the left lower lobe. (author)

  14. T2 hyperintense signal in patients with temporal lobe epilepsy with MRI signs of hippocampal sclerosis and in patients with temporal lobe epilepsy with normal MRI.

    Science.gov (United States)

    Kubota, Bruno Yukio; Coan, Ana Carolina; Yasuda, Clarissa Lin; Cendes, Fernando

    2015-05-01

    Increased MRI T2 signal is commonly present not only in the hippocampus but also in other temporal structures of patients with temporal lobe epilepsy (TLE), and it is associated with histological abnormalities related to the epileptogenic lesion. This study aimed to verify the distribution of T2 increased signal in temporal lobe structures and its correlations with clinical characteristics of TLE patients with (TLE-HS) or without (TLE-NL) MRI signs of hippocampal sclerosis. We selected 203 consecutive patients: 124 with TLE-HS and 79 with TLE-NL. Healthy controls (N=59) were used as a comparison group/comparative group. T2 multiecho images obtained via a 3-T MRI were evaluated with in-house software. T2 signal decays were computed from five original echoes in regions of interest in the hippocampus, amygdala, and white matter of the anterior temporal lobe. Values higher than 2 standard deviations from the mean of controls were considered as abnormal. T2 signal increase was observed in the hippocampus in 78% of patients with TLE-HS and in 17% of patients with TLE-NL; in the amygdala in 13% of patients with TLE-HS and in 14% of patients with TLE-NL; and in the temporal lobe white matter in 22% of patients with TLE-HS and in 8% of patients with TLE-NL. Group analysis demonstrated a significant difference in the distribution of the T2 relaxation times of the hippocampus (ANOVA, ptemporal lobe white matter (ptemporal lobe white matter (ANOVA, p=0.025) for patients with TLE-NL compared with controls. The average signal from the hippocampus ipsilateral to the epileptogenic zone was significantly higher in patients with no family history of epilepsy (two-sample T-test, p=0.005). Increased T2 signal occurs in different temporal structures of patients with TLE-HS and in patients with TLE-NL. The hippocampal hyperintense signal is more pronounced in patients without family history of epilepsy and is influenced by earlier seizure onset. These changes in T2 signal may be

  15. The evolution of Sf. Gheorghe (Danube asymmetric deltaic lobe

    Directory of Open Access Journals (Sweden)

    Alfred VESPREMEANU-STROE

    2014-11-01

    Full Text Available The wave asymmetric Sf. Gheorghe lobe is the only active in the Danube delta where river mouth bar (and the associated barrier islands and spits continuously deployed a cyclic development for almost two millennia. During first stage, the Sf. Gheorghe distributary had a small discharge (with an order of magnitude lower than present which after that experienced a rapid increase in consequence of the successive avulsions of Împuţita (southern distributary of Sulina arm and Dunavăţ distributaries. Our morphological analyses together with the newly obtained chronology, revealed the multiple ridgesets structure of Sf. Gheorghe deltaic lobe. In fact, all ridgesets (10 follow a common morphodynamic pattern characterized by the cyclic succession of three stages: i subaqueous mouth bar development, ii barrier island emergence, iii barrier spit phase with several secondary spits derived from an updrift trunk ridge. The size of each ridgeset increased exponentially with every new cycle due to the constant lengthening of the coastline as the downdrift side of the lobe advances seaward through a series of progressively larger similar quadrilaterals, yielding to a constant enlargment of the delta front size. 

  16. Ecdysone-dependent and ecdysone-independent programmed cell death in the developing optic lobe of Drosophila.

    Science.gov (United States)

    Hara, Yusuke; Hirai, Keiichiro; Togane, Yu; Akagawa, Hiromi; Iwabuchi, Kikuo; Tsujimura, Hidenobu

    2013-02-01

    The adult optic lobe of Drosophila develops from the primordium during metamorphosis from mid-3rd larval stage to adult. Many cells die during development of the optic lobe with a peak of the number of dying cells at 24 h after puparium formation (h APF). Dying cells were observed in spatio-temporal specific clusters. Here, we analyzed the function of a component of the insect steroid hormone receptor, EcR, in this cell death. We examined expression patterns of two EcR isoforms, EcR-A and EcR-B1, in the optic lobe. Expression of each isoform altered during development in isoform-specific manner. EcR-B1 was not expressed in optic lobe neurons from 0 to 6h APF, but was expressed between 9 and 48 h APF and then disappeared by 60 h APF. In each cortex, its expression was stronger in older glia-ensheathed neurons than in younger ones. EcR-B1 was also expressed in some types of glia. EcR-A was expressed in optic lobe neurons and many types of glia from 0 to 60 h APF in a different pattern from EcR-B1. Then, we genetically analyzed EcR function in the optic lobe cell death. At 0 h APF, the optic lobe cell death was independent of any EcR isoforms. In contrast, EcR-B1 was required for most optic lobe cell death after 24 h APF. It was suggested that cell death cell-autonomously required EcR-B1 expressed after puparium formation. βFTZ-F1 was also involved in cell death in many dying-cell clusters, but not in some of them at 24 h APF. Altogether, the optic lobe cell death occurred in ecdysone-independent manner at prepupal stage and ecdysone-dependent manner after 24 h APF. The acquisition of ecdysone-dependence was not directly correlated with the initiation or increase of EcR-B1 expression. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Familial temporal lobe epilepsy due to focal cortical dysplasia type IIIa.

    Science.gov (United States)

    Fabera, Petr; Krijtova, Hana; Tomasek, Martin; Krysl, David; Zamecnik, Josef; Mohapl, Milan; Jiruska, Premysl; Marusic, Petr

    2015-09-01

    Focal cortical dysplasia (FCD) represents a common cause of refractory epilepsy. It is considered a sporadic disorder, but its occasional familial occurrence suggests the involvement of genetic mechanisms. Siblings with intractable epilepsy were referred for epilepsy surgery evaluation. Both patients were examined using video-EEG monitoring, MRI examination and PET imaging. They underwent left anteromedial temporal lobe resection. Electroclinical features pointed to left temporal lobe epilepsy and MRI examination revealed typical signs of left-sided hippocampal sclerosis and increased white matter signal intensity in the left temporal pole. PET examination confirmed interictal hypometabolism in the left temporal lobe. Histopathological examination of resected tissue demonstrated the presence FCD type IIIa, i.e. hippocampal sclerosis and focal cortical dysplasia in the left temporal pole. We present a unique case of refractory mesial temporal lobe epilepsy in siblings, characterized by an identical clinical profile and histopathology of FCD type IIIa, who were successfully treated by epilepsy surgery. The presence of such a high concordance between the clinical and morphological data, together with the occurrence of epilepsy and febrile seizures in three generations of the family pedigree points towards a possible genetic nature of the observed FCD type IIIa. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  18. Insight in psychotic disorder: relation with psychopathology and frontal lobe function.

    Science.gov (United States)

    Kumar, Atmesh; Sharma, Pranjal; Das, Shyamanta; Nath, Kamal; Talukdar, Uddip; Bhagabati, Dipesh

    2014-01-01

    Through conceptualising poor insight in psychotic disorders as a form of anosognosia, frontal lobe dysfunction is often ascribed a vital role in its pathogenesis. The objective of this study was to compare the relation of insight in patients with psychotic illness to that of psychopathology and frontal lobe function. Forty patients with psychotic disorder were selected from those attending the Department of Psychiatry in a tertiary care teaching hospital. The evaluation of insight was carried out using the Schedule for Assessment of Insight (SAI), that of frontal lobe function by the Frontal Assessment Battery (FAB) and psychopathology by the Brief Psychiatric Rating Scale (BPRS). The correlation coefficients were determined. A negative correlation between SAI and BPRS scores means that the BPRS score is opposite to SAI scores. When the SAI total score was compared with the FAB total score, the correlation coefficient demonstrated a positive correlation. Better insight predicted lesser psychopathology and also that poor insight would exist with greater psychopathology. Better insight predicted a higher functional status of frontal lobes and prefrontal cortex in particular. Insight deficits in schizophrenia and other psychotic illnesses are multidimensional. Integration of different aetiological factors like biological, psychopathological, environmental ones and others are necessary for a better understanding of insight in psychosis. Copyright © 2013 S. Karger AG, Basel.

  19. The auroral and ionospheric flow signatures of dual lobe reconnection

    Directory of Open Access Journals (Sweden)

    S. M. Imber

    2006-11-01

    Full Text Available We present the first substantial evidence for the occurrence of dual lobe reconnection from ionospheric flows and auroral signatures. The process of dual lobe reconnection refers to an interplanetary magnetic field line reconnecting with lobe field lines in both the northern and southern hemispheres. Two bursts of sunward plasma flow across the noon portion of the open/closed field line boundary (OCB, indicating magnetic flux closure at the dayside, were observed in SuperDARN radar data during a period of strongly northward IMF. The OCB is identified from spacecraft, radar backscatter, and auroral observations. In order for dual lobe reconnection to take place, we estimate that the interplanetary magnetic field clock angle must be within ±10° of zero (North. The total flux crossing the OCB during each burst is small (1.8% and 0.6% of the flux contained within the polar cap for the two flows. A brightening of the noon portion of the northern auroral oval was observed as the clock angle passed through zero, and is thought to be due to enhanced precipitating particle fluxes due to the occurrence of reconnection at two locations along the field line. The number of solar wind protons captured by the flux closure process was estimated to be ~2.5×1030 (4 tonnes by mass, sufficient to populate the cold, dense plasma sheet observed following this interval.

  20. Pathways of seizure propagation from the temporal to the occipital lobe.

    Science.gov (United States)

    Jacobs, Julia; Dubeau, François; Olivier, André; Andermann, Frederick

    2008-12-01

    Propagation of ictal epileptic discharges influences the clinical appearance of seizures. Fast propagation from the occipital to temporal lobe has been well described, but until now the reverse direction of spread has not been emphasized. We describe two patients who experienced ictal propagation from temporal to occipital regions. One case presented with amaurosis during a seizure with temporal onset and temporal-occipital spread. In the second, temporal-occipital spread was documented during a seizure, which continued in the occipital lobe for six minutes. Depth electrode studies suggested the temporal ictal onset of seizures in both patients. Propagation from temporal to occipital lobe structures must be considered in the assessment of patients who have seizures with both temporal and occipital features. The propagation may have predictive value for their surgical outcome. The underlying anatomical structure might be the inferior longitudinal fasciculus.