WorldWideScience

Sample records for internal liquid lines

  1. Directed line liquids

    International Nuclear Information System (INIS)

    Kamien, R.D.

    1992-01-01

    This thesis is devoted to the study of ensembles of dense directed lines. These lines are principally to be thought of as polymers, though they also have the morphology of flux lines in high temperature superconductors, strings of colloidal spheres in electrorheological fluids and the world lines of quantum mechanical bosons. The authors discuss how directed polymer melts, string-like formations in electrorheological and ferro-fluids, flux lines in high temperature superconductors and the world lines of quantum mechanical bosons all share similar descriptions. They study a continuous transition in all of these systems, and then study the critical mixing properties of binary mixtures of directed polymers through the renormalization group. They predict the exponents for a directed polymer blend consolute point and a novel two-phase superfluid liquid-gas critical point

  2. Liquidity and International Trade

    OpenAIRE

    Rodriguez-Lopez, Antonio

    2016-01-01

    This paper introduces a framework to study the links between the supply of liquid assets for the financial market and the international allocation of economic activity. Private assets’ liquidity properties - their usefulness as collateral or media of exchange in financial transactions - affect assets’ values and interest rates, with consequences on firm entry, production, aggregate productivity, and total market capitalization. In a closed economy, the liquidity market increases the size and ...

  3. Pressure transient in liquid lines

    International Nuclear Information System (INIS)

    Sun, J.G.; Wang, X.Q.

    1995-01-01

    The pressure surge that results from a step change of flow in liquid pipelines, commonly known as water hammer, was analyzed by an eigenfunction method. A differential-integral Pressure wave equation and a linearized velocity equation were derived from the equations of mass and momentum conservation. Waveform distortion due to viscous dissipation and pipe-wall elastic expansion is characterized by a dimensionless transmission number K. The pressure surge condition, which is mathematically singular, was used in the solution procedure. The exact solutions from numerical calculation of the differential-integral equation provide a complete Pressure transient in the pipe. The problems are also calculated With the general-purpose computer code COMMIX, which solves the exact mass conservation equation and Navier-Stokes equations. These solutions were compared with published experimental results, and agreement was good. The effect of turbulence on the pressure transient is discussed in the light of COMMIX calculational results

  4. Superconducting coherence in a vortex line liquid

    International Nuclear Information System (INIS)

    Chen, T.; Teitel, S.

    1995-01-01

    We carry out simulations of the anisotropic uniformly frustrated 3d XY model, as a model for vortex line fluctuations in high T c superconductors. We compute the phase diagram as a function of temperature and anisotropy, for a fixed applied magnetic field B. We find two distinct phase transitions. Upon heating, there is first a lower T c perpendicular where the vortex line lattice melts and super-conducting coherence perpendicular to the applied magnetic field vanishes. At a higher T cz , within the vortex line liquid, superconducting coherence parallel to the applied magnetic field vanishes. For finite anisotropy, both T c perpendicular and T cz lie well below the crossover from the vortex line liquid to the normal state

  5. Weak point disorder in strongly fluctuating flux-line liquids

    Indian Academy of Sciences (India)

    We consider the effect of weak uncorrelated quenched disorder (point defects) on a strongly fluctuating flux-line liquid. We use a hydrodynamic model which is based on mapping the flux-line system onto a quantum liquid of relativistic charged bosons in 2 + 1 dimensions [P Benetatos and M C Marchetti, Phys. Rev. B64 ...

  6. Liquid metals. Coexistence line, critical parameters, compressibility

    International Nuclear Information System (INIS)

    Filippov, L.P.

    1986-01-01

    Formulae to calculate four characteristic parameters of liquid metals (density, compressibility, critical temperature and individual parameter) according to four initial data are obtained: two values of vapor density and two values of vapor pressure. Comparison between experimental and calculation results are presented for liquid Cs, Na, Li, K, Rb

  7. Internalization, Clearing and Settlement, and Liquidity

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2012-01-01

    Abstract: We study the relation between liquidity in financial markets and post-trading fees (i.e. clearing and settlement fees). The clearing and settlement agent (CSD) faces different marginal costs for different types of transactions. Costs are lower for an internalized transaction, i.e. when

  8. Internal Corrosion Detection in Liquids Pipelines

    Science.gov (United States)

    2012-01-01

    PHMSA project DTRS56-05-T-0005 "Development of ICDA for Liquid Petroleum Pipelines" led to the development of a Direct Assessment (DA) protocol to prioritize locations of possible internal corrosion. The underlying basis LP-ICDA is simple; corrosion ...

  9. Leak test of the pipe line for radioactive liquid waste

    International Nuclear Information System (INIS)

    Machida, Chuji; Mori, Shoji.

    1976-01-01

    In the Tokai Research Establishment, most of the radioactive liquid waste is transferred to a wastes treatment facility through pipe lines. As part of the pipe lines a cast iron pipe for town gas is used. Leak test has been performed on all joints of the lines. For the joints buried underground, the test was made by radioactivity measurement of the soil; and for the joints in drainage ditch by the pressure and bubble methods. There were no leakage at all, indicating integrity of all the joints. On the other hand, it is also known by the other test that the corrosion of inner surface of the piping due to liquid waste is only slight. The pipe lines for transferring radioactive liquid waste are thus still usable. (auth.)

  10. About the Shape of the Melting Line as a Possible Precursor of a Liquid-Liquid Phase Transition

    Science.gov (United States)

    Imre, Attila R.; Rzoska, Sylwester J.

    Several simple, non-mesogenic liquids can exists in two or more different liquid forms. When the liquid-liquid line, separating two liquid forms, meets the melting line, one can expect some kind of break on the melting line, caused by the different freezing/melting behaviour of the two liquid forms. Unfortunately recently several researchers are using this vein of thinking in reverse; seeing some irregularity on the melting line, they will expect a break and the appearance of a liquid-liquid line. In this short paper, we are going to show, that in the case of the high-pressure nitrogen studied recently by Mukherjee and Boehler, the high-pressure data can be easily described by a smooth, break-free function, the modified Simon-Glatzel equation. In this way, the break, suggested by them and consequently the suggested appearance of a new liquid phase of the nitrogen might be artefacts.

  11. Estimating International Poverty Lines from Comparable National Thresholds

    OpenAIRE

    Jolliffe, Dean; Prydz, Espen Beer

    2016-01-01

    World Bank's international poverty line of $1.90/day, at 2011 purchasing power parity, is based on a collection of national poverty lines, which were originally used to set the international poverty line of $1.25/day at 2005 purchasing power parity. This paper proposes an approach for estimating a more recent, complete, and comparable collection of national poverty thresholds from reported...

  12. Stokes flow inside an evaporating liquid line for any contact angle

    Science.gov (United States)

    Petsi, A. J.; Burganos, V. N.

    2008-09-01

    Evaporation of droplets or liquid films lying on a substrate induces internal viscous flow, which affects the transport of suspended particles and, thus, the final deposit profile in numerous applications. In this work, the problem of Stokes flow inside a two-dimensional droplet, representing the cross section of an evaporating liquid line lying on a flat surface, is considered. The stream function formulation is adopted, leading to the biharmonic equation in bipolar coordinates. A solution in closed form is obtained for any contact angle in (0,π) and is, thus, valid for both hydrophilic and hydrophobic substrates. The solution can be used with any type of evaporation mechanism, including diffusion, convection, or kinetically controlled modes. Both pinned and depinned contact lines are considered. For the boundary conditions to be compatible at the contact lines, the Navier slip boundary condition is applied on the substrate. Numerical results are presented for kinetically and diffusion controlled evaporation. For pinned contact lines, the flow inside the evaporating liquid line is directed towards the edges, thus, promoting the coffee stain phenomenon. In the case of depinned contact lines and contact angle less than π/2 , the flow is directed towards the center of the droplet, whereas, for strongly hydrophobic substrates it is directed outwards.

  13. Draining Collars and Lenses in Liquid-Lined Vertical Tubes.

    Science.gov (United States)

    Jensen

    2000-01-01

    The speed at which an annular liquid collar drains under gravity g in a vertical tube of radius a, when the tube has an otherwise thin viscous liquid lining on its interior, is determined by a balance between the collar's weight and viscous shear stresses confined to narrow regions in the neighborhood of the collar's effective contact lines. Whether a collar grows or shrinks in volume as it drains depends on the modified Bond number B=rho g a(2)/(sigmaepsilon), where rho is the fluid density, sigma is its surface tension, and epsilona is the thickness of the thin film immediately ahead of the collar. Asymptotic methods are used here to determine the following nonlinear stability criteria for an individual collar, valid in the limit of small epsilon. For 0draining collars grow in volume and, in sufficiently long tubes, ultimately "snap off" to form stable lenses. For 0.5960drain, so that any lens ultimately ruptures, unless stabilizing intermolecular forces allow the formation of a lamella supported by a macroscopic Plateau border. If surfactant immobilizes the liquid's free surface, these critical values of B are reduced by a factor of 2 but the distance a collar must travel before it snaps off is unchanged. Gravitationally driven snap off is therefore most likely to occur in long tubes with radii substantially less than the capillary lengthscale sigma/rhog)(1/2). Copyright 2000 Academic Press.

  14. Spontaneous Marangoni Mixing of Miscible Liquids at a Liquid-Liquid-Air Contact Line.

    Science.gov (United States)

    Kim, Hyoungsoo; Lee, Jeongsu; Kim, Tae-Hong; Kim, Ho-Young

    2015-08-11

    We investigate the flow patterns created when a liquid drop contacts a reservoir liquid, which has implications on various physicochemical and biochemical reactions including mixing in microfluidic systems. The localized vortical flow spontaneously triggered by the difference of surface tension between the two liquids is studied, which is thus termed the Marangoni vortex. To quantitatively investigate the strength of vortices, we performed particle image velocimetry (PIV) experiments by varying the surface tension difference, the gap of the flow cell, the density and viscosity of the reservoir liquid, and the size of the drop. A scaling law that balances the interfacial energy of the system with the kinetic energy of the vortical flows allows us to understand the functional dependence of the Marangoni vortex strength on various experimental parameters.

  15. On-line control of a liquid-liquid extraction column by the modal control method

    International Nuclear Information System (INIS)

    Bonnefoi, P.; Poujol, A.; Zwingelstein, G.; Dargier, C.; Rouyer, H.

    1977-02-01

    The application of modal analysis to the on-line control of a liquid-liquid extraction column is presented. This process is used in reprocessing for U purification. U in the aqueous acid phase is extracted by a solvent flowing at counter-current. The process is described by 4 nonlinear equations and gives the U and acid concentrations in the two phases. An approximative model is established adapted to the control of the column. Some results of a numerical simulation are given when a single mode is controled. They show that a single sensor allows a good control [fr

  16. Absolute quantification of NAD(P)H:quinone oxidoreductase 1 in human tumor cell lines and tissues by liquid chromatography–mass spectrometry/mass spectrometry using both isotopic and non-isotopic internal standards

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Zhiyuan; Wu, Mengqiu; Li, Yingchun; Zheng, Xiao; Liu, Huiying; Cheng, Xuefang [State Key Laboratory of Natural Medicines, Key Lab of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009 (China); Xu, Lin [Department of Thoracic Surgery, Jiangsu Cancer Hospital, Nanjing 210009 (China); Wang, Guangji, E-mail: guangjiwang@hotmail.com [State Key Laboratory of Natural Medicines, Key Lab of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009 (China); Hao, Haiping, E-mail: hhp_770505@yahoo.com.cn [State Key Laboratory of Natural Medicines, Key Lab of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009 (China)

    2013-04-15

    Highlights: ► The peptide fingerprint map of NQO1 has been defined by using TripleTOF. ► Signature peptide of NQO1 can be quickly quantified within 10 min. ► Analysis is performed with non-isotopic analog and compared with isotopic method. ► This method is adequate for NQO1 quantitation from human cancer cells and tissues. -- Abstract: NAD(P)H:quinone oxidoreductase 1 (NQO1, DT-diaphorase) is a prognostic biomarker and a potential therapeutic target for various tumors. Therefore, it is of significance to develop a robust method for the absolute quantification of NQO1. This study aimed to develop and validate a LC–MS/MS based method and to test the appropriateness of using non-isotopic analog peptide as the internal standard (IS) by comparing with a stable isotope labeled (SIL) peptide. The chromatographic performance and mass spectra between the selected signature peptide of NQO1 and the non-isotopic peptide were observed to be very similar. The use of the two internal standards was validated appropriate for the absolute quantification of NQO1, as evidenced by satisfactory validation results over a concentration range of 1.62–162 fmol μL{sup −1}. This method has been successfully applied to the absolute quantification of NQO1 expression in various tumor cell lines and tissues. NQO1 expression in human tumor tissues is much higher than that in the neighboring normal tissues in both the cases of lung and colon cancer. The quantitative results obtained from the isotopic and non-isotopic methods are quite similar, further supporting that the use of non-isotopic analog peptide as internal standard is appropriate and feasible for the quantification of NQO1. By comparing with a classical isotopic IS, the present study indicates that the use of a non-isotopic peptide analog to the proteotypic peptide as the internal standard can get equal accuracy and preciseness in measuring NQO1. The universal applicability of the non-isotopic IS approach for the

  17. Isoviscosity lines and the liquid-glass transition in simple liquids.

    Science.gov (United States)

    Fomin, Yu D; Brazhkin, V V; Ryzhov, V N

    2012-07-01

    This article presents the study of the generic behavior of viscosity of liquids based on some simple theoretical models, the soft-spheres and Lennard-Jones systems. The use of these simple models allows us to investigate in detail the viscosity behavior in a wide range of temperatures and pressures including the high-temperature-high-pressure limits. Based on the simulation results, we discuss the shape of isoviscosity lines and analyze the glass transition at high temperatures and high pressures. Despite the fact that the viscosity drastically increases in the limit of high temperatures and high pressures along the melting line, the relaxation time rapidly decreases in this region, and the system becomes further from the glass transition.

  18. The influence of triple bottom line on international operations management

    Directory of Open Access Journals (Sweden)

    Francisco Sperotto Flores

    2017-12-01

    Full Text Available This paper takes a triple bottom line perspective to analyze how the international operations literature integrates economic, social, and environmental issues. Additionally, it shows the main drivers of and barriers to the adoption of triple bottom line practices by companies in an international context. We conducted a literature review in English language journals which publish research of production and operations management and sustainability, resulting in a final sample of 29 papers. Results show that social and legal pressure for companies to adopt a responsible behavior prompts an isomorphic process that leads them to conduct their operations on behalf of triple bottom line goals. Behavioral differences between spin-offs in various countries caused institutions to create mechanisms that can press and change private standards through regulation and enforcement. There is room for progress in studies that seek to analyze the company’s relationships in its international experience and its multi-institutional relations.

  19. Liquidity, Investors and International Capital Markets

    NARCIS (Netherlands)

    D. Vagias

    2013-01-01

    textabstractThis dissertation consists of four empirical studies that seek to furnish a better understanding over liquidity’s broader implications in the decision-making process of investors, managers and regulators in international capital markets. Chapter 2 investigates the time-series as well as

  20. Internal friction behavior of liquid Bi-Sn alloys

    International Nuclear Information System (INIS)

    Wu Aiqing; Guo Lijun; Liu Changsong; Jia Erguang; Zhu Zhengang

    2005-01-01

    Pure Bi and Sn and four Bi-Sn alloys distributed on the entire concentration range were selected for internal-friction investigation over a wide temperature range. There exist two peaks in the plots of internal friction versus temperature for liquid Sn, Bi-Sn60 and Bi-Sn90 alloys, one peak being located at about 480 - bar Cand another at about 830 - bar C. Only a single internal-friction peak at about 830 - bar C occurs in liquid Bi-Sn43 (eutectic composition). No internal-friction peak appears in liquid Bi-Sn20 alloy and pure Bi. The height of the internal-friction peaks depends on the content of Sn. The present finding suggests that Sn-rich Bi-Sn alloys may inherit the internal-friction behaviors of pure Sn, whereas Bi-rich Bi-Sn alloy seems to be like pure Bi. The position of the internal-friction peaks is frequency dependent, which resembles the internal-friction feature in structure transition in solids

  1. Internal friction behavior of liquid Bi-Sn alloys

    Energy Technology Data Exchange (ETDEWEB)

    Wu Aiqing [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, P.O. Box 1129, Hefei 230031 (China); Guo Lijun [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, P.O. Box 1129, Hefei 230031 (China); Liu Changsong [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, P.O. Box 1129, Hefei 230031 (China); Jia Erguang [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, P.O. Box 1129, Hefei 230031 (China); Zhu Zhengang [Key Laboratory of Materials Physics, Institute of Solid State Physics, Chinese Academy of Sciences, P.O. Box 1129, Hefei 230031 (China)]. E-mail: zgzhu@issp.ac.cn

    2005-12-01

    Pure Bi and Sn and four Bi-Sn alloys distributed on the entire concentration range were selected for internal-friction investigation over a wide temperature range. There exist two peaks in the plots of internal friction versus temperature for liquid Sn, Bi-Sn60 and Bi-Sn90 alloys, one peak being located at about 480{sup -}bar Cand another at about 830{sup -}bar C. Only a single internal-friction peak at about 830{sup -}bar C occurs in liquid Bi-Sn43 (eutectic composition). No internal-friction peak appears in liquid Bi-Sn20 alloy and pure Bi. The height of the internal-friction peaks depends on the content of Sn. The present finding suggests that Sn-rich Bi-Sn alloys may inherit the internal-friction behaviors of pure Sn, whereas Bi-rich Bi-Sn alloy seems to be like pure Bi. The position of the internal-friction peaks is frequency dependent, which resembles the internal-friction feature in structure transition in solids.

  2. Communication: Glass transition and melting lines of an ionic liquid

    Science.gov (United States)

    Lima, Thamires A.; Faria, Luiz F. O.; Paschoal, Vitor H.; Ribeiro, Mauro C. C.

    2018-05-01

    The phase diagram of the ionic liquid 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesufonyl)imide, [Pyrr1,4][NTf2], was explored by synchroton X-ray diffraction and Raman scattering measurements as a function of temperature and pressure. Glass transition Tg(p) and melting Tm(p) temperatures were obtained from atmospheric pressure up to ca. 2.0 GPa. We found that both the Tg(p) and Tm(p) curves follow essentially the same pressure dependence. The similarity of pressure coefficients, dTg/dp ≈ dTm/dp, is explained within the non-equilibrium thermodynamics approach for the glass transition by assuming that one of the Ehrenfest equations is appropriated for Tg(p), whereas Tm(p) follows the Clausius-Clapeyron equation valid for the first-order transitions. The results highlight that ionic liquids are excellent model systems to address fundamental questions related to the glass transition.

  3. Dynamics, thermodynamics and structure of liquids and supercritical fluids: crossover at the Frenkel line

    Science.gov (United States)

    Fomin, Yu D.; Ryzhov, V. N.; Tsiok, E. N.; Proctor, J. E.; Prescher, C.; Prakapenka, V. B.; Trachenko, K.; Brazhkin, V. V.

    2018-04-01

    We review recent work aimed at understanding dynamical and thermodynamic properties of liquids and supercritical fluids. The focus of our discussion is on solid-like transverse collective modes, whose evolution in the supercritical fluids enables one to discuss the main properties of the Frenkel line separating rigid liquid-like and non-rigid gas-like supercritical states. We subsequently present recent experimental evidence of the Frenkel line showing that structural and dynamical crossovers are seen at a pressure and temperature corresponding to the line as predicted by theory and modelling. Finally, we link dynamical and thermodynamic properties of liquids and supercritical fluids by the new calculation of liquid energy governed by the evolution of solid-like transverse modes. The disappearance of those modes at high temperature results in the observed decrease of heat capacity.

  4. Energy of formation for AgIn liquid binary alloys along the line of phase separation

    CERN Document Server

    Bhuiyan, G M; Ziauddin-Ahmed, A Z

    2003-01-01

    We have investigated the energy of formation for AgIn liquid binary alloys along the solid-liquid phase separation line. A microscopic theory based on the first order perturbation has been applied. The interionic interaction and a reference liquid are the fundamental components of the theory. These are described by a local pseudopotential and the hard sphere liquids, respectively. The results of calculations reveal a characteristic feature that the energy of formation becomes minimum at the equiatomic composition, and thus indicates maximal mix-ability at this concentration. The energy of formation at a particular thermodynamic state that is at T 1173 K predicts the experimental trends fairly well.

  5. Quasi-elastic neutron line broadening in nematic liquid crystals

    International Nuclear Information System (INIS)

    Cvikl, B.; Dimic, V.; Dusic, M.; Kristof, E.; Srebotnjak, E.

    1979-01-01

    On the basis of a new random walk torsional oscillations model of the amplitude φ 0 of rigid flat molecules a quasi-elastic neutron line broadening has been calculated and the results compared to the measurements obtained on the sample of cholesteryl propionate. A good agreement was obtained. (author)

  6. PREFACE: XXII International Conference on Spectral Line Shapes 2014

    Science.gov (United States)

    Parigger, C. G.

    2014-11-01

    The 22nd International Conference on Spectral Line Shapes (ICSLS) was convened at The University of Tennessee Space Institute (UTSI) at Tullahoma, Tennessee, USA, during June 1 to 6, 2014. A variety of topics of interest to the line shape community were addressed during invited and contributed oral and poster presentations. General categories of the ICSLS 2014 scientific contents included Astrophysics, Biomedical Physics, High and Low Temperature Plasma Physics, Magnetic Fusion Physics, Neutrals Atomic-Molecular-Optical (AMO) Physics, and Applied Physics. Research interests at UTSI and at the Center for Laser Applications (CLA) focus on Applied Physics and Plasma Physics areas such as laser-induced breakdown spectroscopy, spectroscopy with ultra-short light pulses, combustion diagnostics, to name a few. Consequently, the presentations during the conference addressed a variety of these topics. Attendance at the conference included researchers from North America, Africa, Asia and Europe, with an international representation showing 250 authors and co-authors with over 25 different citizenships, and 100 participants at the Conference. Figure 1 shows a photo of Conference attendees. The schedule included 82 contributions, 41 oral and 41 poster presentations. The 29 invited, 12 contributed oral and 41 contributed poster presentations were selected following communication with the international organizing committee members. A smart phone ''app'' was also utilized, thanks to Elsevier, to communicate electronic versions of the posters during the conference. Special thanks go to the members of the international and local committees for their work in organizing the 22nd ICSLS. In addition, thank you notes also go to the peer reviewers for the proceedings. Following the success of the IOP: Journal of Physics Conference Series selected for the 21st ICSLS publication, the proceedings papers report ongoing research activities. Papers submitted amount to 68 in number, or 83% of

  7. Evaporation-induced flow in an inviscid liquid line at any contact angle

    Science.gov (United States)

    Petsi, A. J.; Burganos, V. N.

    2006-04-01

    The problem of potential flow inside an evaporating liquid line, shaped as an infinitely long cylindrical segment lying on a flat surface, is considered and an analytical solution is obtained for any contact angle in (0,π) . In this way, microflow details inside linear liquid bodies evaporating on hydrophilic, hydrophobic, and strongly hydrophobic substrates can now be obtained. The mathematical formulation employs the velocity potential and stream function formulations in bipolar coordinates and the solution is obtained using the technique of Fourier transform. Both pinned and depinned contact lines are considered. The solution is applicable to any evaporation mechanism but for illustration purposes numerical results are presented here for the particular case of kinetically controlled evaporation. For hydrophilic substrates, the flow inside the evaporating liquid line is directed towards the edges for pinned contact lines, thus, promoting a coffee stain effect. The opposite flow direction is observed for depinned contact lines. However, for strongly hydrophobic substrates, flow is directed outwards for both pinned and depinned contact lines, but owing to its low magnitude compared to that on hydrophilic substrates, a craterlike colloidal deposit should be expected rather than a ringlike deposit, in agreement with experimental observations.

  8. PREFACE: XXI International Conference on Spectral Line Shapes (ICSLS 2012)

    Science.gov (United States)

    Devdariani, Alexander Z.

    2012-12-01

    The 21st International Conference on Spectral Line Shapes, ICSLS, was held in the historic main building of St Petersburg State University (St. Petersburg, Russia) on 3-9 June 2012. The event continued the tradition started in 1978 in Meudon Observatory in Paris. Representatives of line shape physics have since met every two years in different locations in Europe and North America. The most recent events were held in St John's, Newfoundland, Canada (2010), Valladolid, Spain (2008), and Auburn, AL (USA). Traditionally, the conferences consider experimental and theoretical issues of studying spectral line shapes, diagnostic utilization of spectral line profiles observed in absorption, emission or scattering of electromagnetic radiation by atoms, molecules, and clusters in different environments, including neutral environments, laboratory low and fusion plasmas, astrophysical conditions, and planetary atmospheres. The Conference was attended by over 100 professionals from Europe, Asia, America, Africa and New Zealand. The conference program was put together in such a way so as to exclude any parallel sessions. Five afternoon sessions featured 19 invited talks and 20 oral contributions, and two evening sessions offered 61 poster presentations, including post-deadline posters. This setup allowed for a relaxed and unhurried discussion of results and facilitated productive networking. The invited talks were selected by recommendation of members of the International Scientific Committee. The Organizers would like to thank all the members of the International Scientific Committee for their proposals on the agenda and their valuable advice. When considering candidates for oral contributions, the organizers took into account the suggestions and preferences of potential conference participants. When selecting the theses of poster presentations, the organizers focused on the topics in line with the theme of the conference and studies with well-formulated results. It must be

  9. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, U.

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and

  10. Construction of Lines of Constant Density and Constant Refractive Index for Ternary Liquid Mixtures.

    Science.gov (United States)

    Tasic, Aleksandar Z.; Djordjevic, Bojan D.

    1983-01-01

    Demonstrates construction of density constant and refractive index constant lines in triangular coordinate system on basis of systematic experimental determinations of density and refractive index for both homogeneous (single-phase) ternary liquid mixtures (of known composition) and the corresponding binary compositions. Background information,…

  11. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical

  12. Federal Reserve Swap LinesInternational Lender of the Last Resort

    Directory of Open Access Journals (Sweden)

    Miroslav Titze

    2016-08-01

    Full Text Available After 2007, financial market turmoil began and shortage of dollar funding liquidity disrupted not only the US dollar funding market but also overseas. To address the shortage of dollar liquidity, the FED introduced swap lines with systematic important central banks, including emerging markets. The paper discusses the main feature of the FED’s swap lines in the context of the funding pressures on the FX swap market. The main objective of the paper is to reveal technical aspects and effectiveness of the swap lines. The paper explains connectivity between un/secured money markets and the FX swap market during the financial and debt crises. The FX swap market was hit significantly. During the liquidity crisis of 2007–2010, the main driver of the deviation from covered interest parity was a shortage of dollar liquidity jointly with counterparty risk. During the debt crisis, the main driver was counterparty risk of the euro zone banks and sovereigns. The FED swap lines were used as a liquidity backstop. The paper concludes that the swap lines were an effective tool of cooperation between central banks and significantly alleviated the pressure on the FX swap market. In addition, the swap lines were flexible, supported financial stability, no losses were recorded, the problem of adverse selection was avoided and exit was successful. Finally, the swap lines have become a permanent tool for solving temporary shortages of foreign currency liquidity in national banking systems.

  13. PREFACE: 13th International Conference on Liquid and Amorphous Metals

    Science.gov (United States)

    Popel, Pjotr; Gelchinskii, Boris; Sidorov, Valeriy; Son, Leonid; Sabirzjanov, Alexandre

    2007-06-01

    The state of the art in the field of liquid and amorphous metals and alloys is regularly updated through two series of complementary international conferences, the LAM (Liquid and Amorphous Metals) and the RQ (Rapidly Quenched Materials). The first series of the conferences started as LM-1 in 1966 at Brookhaven for the basic understanding of liquid metals. The subsequent LM conferences were held in Tokyo (1972) and Bristol (1976). The conference was renewed in Grenoble (1980) as a LAM conference including amorphous metals and continued in Los Angeles (1983), Garmisch-Partenkirchen (1986), Kyoto (1989), Vienna (1992), Chicago (1995), Dortmund (1998), Yokohama (2001) and Metz (2004). The conferences are mainly devoted to liquid and amorphous metals and alloys. However, communications on some non-metallic systems such as semi conductors, quasicrystals etc, were accepted as well. The conference tradition strongly encourages the participation of junior researchers and graduate students. The 13th conference of the LAM series was organized in Ekaterinburg, Russia, by the Institute of Metallurgy of the Ural Branch of the Russian Academy of Sciences (IMet UB RAS) and Ural State Pedagogical University (USPU) and held on 8-13 July 2007 under the chairmanship of Professors Pjotr Popel (USPU) and Boris Gelchinskii (IMet UB RAS). There were 242 active and about 60 guest participants from 20 countries who attended the conference. There were no parallel sessions and all oral reports were separated into three groups: invited talks (40 min), full-scale (25 min) and brief (15 min) oral reports. The program included 10 sessions, ranging from purely theoretical subjects to technological application of molten and amorphous alloys. The following sessions took place: A) Electronic structure and transport, magnetic properties; B) Phase transitions; C) Structure; D) Atomic dynamics and transport; E) Thermodynamics; F) Modelling, simulation; G) Surface and interface; H) Mechanical properties

  14. Liquidity in Retirement Savings Systems: An International Comparison

    OpenAIRE

    Beshears, John Leonard; Choi, James J.; Hurwitz, Joshua Bayard; Laibson, David I.; Madrian, Brigitte

    2015-01-01

    What is the socially optimal level of liquidity in a retirement savings system? Liquid retirement savings are desirable because liquidity enables agents to flexibly respond to pre-retirement events that raise the marginal utility of consumption. On the other hand, pre-retirement liquidity is undesirable when it leads to under-saving arising from, for example, planning mistakes or self-control problems. This paper compares the liquidity that six developed economies have built into their employ...

  15. In line digital holography measurement for liquid-liquid flow: application to the characterization of emulsions produced in pulsed column

    International Nuclear Information System (INIS)

    Lamadie, F.

    2013-01-01

    Several processes used in research and industry are based on liquid-liquid extraction, a method designed for selective separation of products in a mixture. In liquid-liquid extraction, two immiscible liquids are contacted: an aqueous phase and an organic phase, one of which generally contains an extractant molecule capable of transferring the desired elements to the other phase. The transfer occurs at the contact surface between the two phases. After transfer, both phases are separated by settling. In practice, these operations are performed in industrial apparatus. In order to optimize the operation of these devices, it's important to determine the fundamental characteristics of the emulsion. These include parameters related to the fluid flow velocity as well as parameters related to fluid mixing such as the interfacial area, hold-up, and size distribution of the droplets population. Numerous imaging techniques can be used to measure these parameters. One of them, digital holography, is well-known for allowing complete reconstruction of information about a 3D flow in a single shot. This PhD work deals with a direct application of digital in line holography to droplets rising in a continuous liquid phase. The droplet size imposes a regime of intermediate-field diffraction hardly explored to date. Acquired diffraction patterns show that the usual dark disk model is not valid and that good agreement is obtained with a mixed model coupling thin lens with opaque disk. Hologram focusing is nevertheless performed with a dedicated automated method. A literature review has been conducted to identify the sharpest auto-focus function for our application. In a second step, in order to measure high retention rates, an inverse problem approach is applied on all the outliers and missing droplets. This hologram restitution treatment has been applied to experimental results with a comparison to independent measurements. The main results obtained with calibrated droplets are

  16. Study on Gas-liquid Falling Film Flow in Internal Heat Integrated Distillation Column

    Science.gov (United States)

    Liu, Chong

    2017-10-01

    Gas-liquid internally heat integrated distillation column falling film flow with nonlinear characteristics, study on gas liquid falling film flow regulation control law, can reduce emissions of the distillation column, and it can improve the quality of products. According to the distribution of gas-liquid mass balance internally heat integrated distillation column independent region, distribution model of heat transfer coefficient of building internal heat integrated distillation tower is obtained liquid distillation falling film flow in the saturated vapour pressure of liquid water balance, using heat transfer equation and energy equation to balance the relationship between the circulating iterative gas-liquid falling film flow area, flow parameter information, at a given temperature, pressure conditions, gas-liquid flow falling film theory makes the optimal parameters to achieve the best fitting value with the measured values. The results show that the geometric gas-liquid internally heat integrated distillation column falling film flow heat exchange area and import column thermostat, the average temperature has significant. The positive correlation between the heat exchanger tube entrance due to temperature difference between inside and outside, the heat flux is larger, with the increase of internal heat integrated distillation column temperature, the slope decreases its temperature rise, which accurately describes the internal gas-liquid heat integrated distillation tower falling film flow regularity, take appropriate measures to promote the enhancement of heat transfer. It can enhance the overall efficiency of the heat exchanger.

  17. On-line radiometry in high-performance liquid chromatography using a storage loop

    International Nuclear Information System (INIS)

    Nieuwkerk, H.J. van.

    1987-01-01

    Difficulty with radiometric chromatography is that large measured volumes are required for accurate detections, but large volumes cause band widening and thus poor separation capacity. The solution proposed here is based on the use of a capillary storage loop for temporary residence of the column eluate. To avoid back mixing, the liquid is interspaced with a second, immiscible, phase ('spacer') so as to form a sequence of small 10-50 μl separate segments. This train passes the on-line radiometric detector to obtain a first scan of the chromatogram, called the 'direct' measurement. It then reaches the storage loop. The usual on-line UV measurement is done in the same run. The eluate cum spacer is, at a later stage, pumped through the detector at a greatly reduced flow rate to obtain the 'reversed' or 'delayed' measurement. Beta-detection is based on liquid scintillation. Accordingly, the (organic) liquid scintillant is used as the 'spacer'. In most cases it is possible to extract the analyte from the aqueous eluate into the organic phase during transport to and storage in the loop. This ensures a high counting efficiency. If the analyte is non-extractable, the counting efficiency is considerably less but the number of counts collected is still sufficient for quantitative assay, due to the extended counting time. The report is divided into 5 chapters, each dealing with a radiometric HPCL separation making use of this method. 36 figs.; 124 refs.; 16 tables

  18. Calorimetry by immersion into liquid nitrogen and liquid argon: a better way to determine the internal surface area of micropores.

    Science.gov (United States)

    Navarrete, Ricardo; Llewellyn, Philip; Rouquerol, Françoise; Denoyel, Renaud; Rouquerol, Jean

    2004-09-15

    The aim of this work is to assess the internal surface area of a set of samples (either carbons or oxides, either porous or nonporous, either microporous or mesoporous) by microcalorimetry via immersion into liquid nitrogen or argon. We have made use of an isothermal, heat-flux microcalorimeter, initially designed and built in our laboratory for the sake of gas adsorption experiments at 77 or 87 K. It seems that immersion calorimetry into liquid nitrogen and argon makes it possible to go one step further in the determination of the internal surface area of micropores.

  19. Poverty Lines in History, Theory, and Current International Practice

    OpenAIRE

    Robert Allen

    2013-01-01

    This paper compares historical poverty baskets to modern food security and poverty lines. Changes in the historical baskets and indexing methods are proposed to bring historical studies into better alignment with modern measures as well as with historically based estimates of energy requirements. In addition, it is argued that modern poverty measures could be improved by emulating the historical methods.

  20. In-line Kevlar filters for microfiltration of transuranic-containing liquid streams.

    Science.gov (United States)

    Gonzales, G J; Beddingfield, D H; Lieberman, J L; Curtis, J M; Ficklin, A C

    1992-06-01

    The Department of Energy Rocky Flats Plant has numerous ongoing efforts to minimize the generation of residue and waste and to improve safety and health. Spent polypropylene liquid filters held for plutonium recovery, known as "residue," or as transuranic mixed waste contribute to storage capacity problems and create radiation safety and health considerations. An in-line process-liquid filter made of Kevlar polymer fiber has been evaluated for its potential to: (1) minimize filter residue, (2) recover economically viable quantities of plutonium, (3) minimize liquid storage tank and process-stream radioactivity, and (4) reduce potential personnel radiation exposure associated with these sources. Kevlar filters were rated to less than or equal to 1 mu nominal filtration and are capable of reducing undissolved plutonium particles to more than 10 times below the economic discard limit, however produced high back-pressures and are not yet acid resistant. Kevlar filters performed independent of loaded particles serving as a sieve. Polypropylene filters removed molybdenum particles at efficiencies equal to Kevlar filters only after loading molybdenum during recirculation events. Kevlars' high-efficiency microfiltration of process-liquid streams for the removal of actinides has the potential to reduce personnel radiation exposure by a factor of 6 or greater, while simultaneously achieving a reduction in the generation of filter residue and waste by a factor of 7. Insoluble plutonium may be recoverable from Kevlar filters by incineration.

  1. Raman study of pressure effects on frequencies and isotropic line shapes in liquid acetone

    International Nuclear Information System (INIS)

    Schindler, W.; Sharko, P.T.; Jonas, J.

    1982-01-01

    The Raman line shape of the symmetric C = O stretching band at 1710 cm -1 has been measured in liquid acetone as a function of pressure from 1 bar to 4 kbar over the temperature range from -25 to 50 0 C. The experimental data obtained show several unusual features. First, there is a frequency difference of about 7 cm -1 between the polarized and depolarized components. Sceond, the isotropic linewidth GAMMA/sub iso/ decreases with increasing density, in contrast to the opposite trend usually found in other liquids. Third, the second moment M 2 (V) of the isotropic band appears to decrease with increasing density. The consideration of the experimental linewidth and frequency data leads to a conclusion that intermolecular dipole--dipole coupling between polar acetone molecules are responsible for the observed unusual behavior of , GAMMA/sub iso/, and M 2

  2. 75 FR 35366 - Pipeline Safety: Applying Safety Regulation to All Rural Onshore Hazardous Liquid Low-Stress Lines

    Science.gov (United States)

    2010-06-22

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Onshore Hazardous Liquid Low-Stress Lines AGENCY: Pipeline and Hazardous Materials Safety Administration... to the risks that hazardous liquid and natural gas pipelines pose to the environment. In the Pipeline...

  3. Retrograde Melting and Internal Liquid Gettering in Silicon

    Energy Technology Data Exchange (ETDEWEB)

    Hudelson, Steve; Newman, Bonna K.; Bernardis, Sarah; Fenning, David P.; Bertoni, Mariana I.; Marcus, Matthew A.; Fakra, Sirine C.; Lai, Barry; Buonassisi, Tonio

    2011-07-01

    Retrograde melting (melting upon cooling) is observed in silicon doped with 3d transition metals, via synchrotron-based temperature-dependent X-ray microprobe measurements. Liquid metal-silicon droplets formed via retrograde melting act as efficient sinks for metal impurities dissolved within the silicon matrix. Cooling results in decomposition of the homogeneous liquid phase into solid multiple-metal alloy precipitates. These phenomena represent a novel pathway for engineering impurities in semiconductor-based systems.

  4. A spin-liquid with pinch-line singularities on the pyrochlore lattice.

    Science.gov (United States)

    Benton, Owen; Jaubert, L D C; Yan, Han; Shannon, Nic

    2016-05-26

    The mathematics of gauge theories lies behind many of the most profound advances in physics in the past 200 years, from Maxwell's theory of electromagnetism to Einstein's theory of general relativity. More recently it has become clear that gauge theories also emerge in condensed matter, a prime example being the spin-ice materials which host an emergent electromagnetic gauge field. In spin-ice, the underlying gauge structure is revealed by the presence of pinch-point singularities in neutron-scattering measurements. Here we report the discovery of a spin-liquid where the low-temperature physics is naturally described by the fluctuations of a tensor field with a continuous gauge freedom. This gauge structure underpins an unusual form of spin correlations, giving rise to pinch-line singularities: line-like analogues of the pinch points observed in spin-ice. Remarkably, these features may already have been observed in the pyrochlore material Tb2Ti2O7.

  5. Analysis And Comments On The Consultative Document: International Framework For Liquidity Risk Measurement, Standards And Monitoring

    OpenAIRE

    Jacques Prefontaine; Jean Desrochers; Lise Godbout

    2010-01-01

    The market turmoil that began in mid-2007 re-emphasized the importance of liquidity to the functioning of financial markets and the banking sector. In December 2009, the Basel Committee on Banking Supervision (BCBS) of the Bank for International Settlements (BIS) released a consultative document entitled: “International Framework for Liquidity Risk Measurement, Standards and Monitoring”. Interested parties were invited to provide written comments by April 16th 2010. Given our interest in prom...

  6. Implementing an ambidextrous sales strategy at the front line: an internal marketing perspective

    NARCIS (Netherlands)

    van der Borgh, W.; de Jong, A.; Nijssen, E.J.; Ahearne, M.; Bigné, E.

    2014-01-01

    Ambidextrous sales strategies, wherein managers pursue the concurrent sale of new and existing products, often fail at the front line. A proposed internal marketing perspective accounts for the role of two vertical relational mechanisms (manager ambidexterity and salesperson organizational

  7. College Students' Choice Modeling of Taking On-Line International Business Courses

    Science.gov (United States)

    Yeh, Robert S.

    2006-01-01

    To understand students' choice behavior of taking on-line international business courses, a survey study is conducted to collect information regarding students' actual choices of taking on-line courses and potential factors that may have impacts on students' choices of online learning. Potential factors such as enrollment status, demographic…

  8. Devolving HRM and HRD to Line managers: The Case of Hilton International's UK Hotels

    Science.gov (United States)

    Maxwell, Gillian; Watson, Sandra

    2004-01-01

    This paper explores line manager responsibility for human resource management (HRM) and human resource development (HRD) in an international hotel organisation. The results identify a strong support system for line managers in relation to training and good relations with HR specialists. However, less evident is senior management support coupled…

  9. Investigation of internal conversion electron lines by track counting technique

    CERN Document Server

    Islamov, T A; Kambarova, N T; Muminov, T M; Lebedev, N A; Solnyshkin, A A; Aleshin, Yu D; Kolesnikov, V V; Silaev, V I; Niipf-Tashgu, T

    2001-01-01

    The methodology of counting the tracks of the internal conversion electron (ICE) in the nuclear photoemulsion is described. The results on counting the ICE tracks on the photoplates for sup 1 sup 6 sup 1 Ho, sup 1 sup 6 sup 3 Tm, sup 1 sup 6 sup 6 Tm, sup 1 sup 3 sup 5 Ce is described. The above results are obtained through the MBI-9 microscope and the MAS-1 automated facility. The ICE track counting on the photoplates provides for essentially higher sensitivity as compared to the photometry method. This makes it possible to carry out measurements with the sources by 1000 times weaker as by the study into the density of blackening

  10. Innovative in-line separators: removal of water or sand in oil/water and gas/liquid/solid pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Jepson, Paul; Cheolho Kang; Gopal, Madan [CC Technologies, Dublin, OH (United States)

    2003-07-01

    In oil and gas production, multiphase mixtures are often separated before downstream processing. The separators are large, often 20 - 40 feet long and large diameter and use sophisticated internals. The costs are in the millions of dollars. Further, the sand and water in the flow can cause severe internal erosion and corrosion respectively before the flow reaches the separators. The CC Technologies/MIST In line Separation System is a cost-effective, efficient device for use in multiphase environments. The device is applicable for gas/solid, gas/liquid/solid and oil/water systems and offers exceptional separation between phases for a fraction of the cost of expensive gravity separators and hydro cyclones. The System contains no moving parts and is designed to be of the same diameter as the pipe, and experiences low shear forces. It can be fabricated with standard pipes. The efficiency of the separator has been determined in an industrial scale, pilot plant test facility at CC Technologies in 4-inch diameter pipes and has been found to be in excess of 98-99% for the removal of sand. Two phase oil/water separation effectiveness is in excess of 90% in 1-stage and 95% in 2 - stage. (author)

  11. Radioactive liquid wastes lines removal project at Los Alamos (1981-1986)

    International Nuclear Information System (INIS)

    Elder, J.C.; Cox, E.J.; Hohner, D.P.; Valentine, A.M.

    1986-09-01

    This report describes the abandoned liquid waste lines removal operations conducted at Los Alamos in the period 1981 to 1986. Particular emphasis has been placed on as-left conditions, that is, on the location of sections of waste lines or contaminated soil which were left in place on the basis of ALARA decisions. Contaminated items were left when interfering utilities, roads, structures, or great depth made complete removal not cost effective or not safe. Left items were either not highly contaminated or they were not near the surface. Total cost of the project was $4.2 million. Approximately 5800 m 3 of contaminated waste was placed in the Solid Waste Management Site at TA-54 Area G. The project accomplished the removal of approximately 34,500 ft (6.5 miles) of abandoned waste lines under carefully controlled conditions. Procedures for excavation, waste disposal, personnel protection, and radiation monitoring are described. Environmental monitoring criteria and methods for determining acceptable levels of contamination in soils and on surfaces are discussed

  12. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. 7th International Conference on Physics of Liquid Matter : Modern Problems

    CERN Document Server

    Chalyi, Alexander

    2018-01-01

    This book presents a collection of selected lectures discussing current problems in molecular physics and reviews the main cutting-edge advances in condensed and soft matter physics. It offers deep insights and a powerful basis for scientists and engineers to study complicated problems in physics, chemistry, biology, and medicine. The unification of experimental, theoretical, and computational methods allows milestone results to be achieved in areas such as ionic and ionic-electronic liquids, magnetic liquid systems, liquid systems with nanoparticles, structural phase transitions and critical phenomena, and small-angle neutron and X-ray scattering in liquids and liquid systems.   The lectures selected for this book were held at the 7th International Conference “Physics of Liquid Matter: Modern Problems” (PLMMP-2016), 27–31 May in Kiev, Ukraine.

  14. A corresponding states treatment of the liquid-vapor saturation line

    International Nuclear Information System (INIS)

    Srinivasan, K.; Ng, K.C.; Velasco, S.; White, J.A.

    2012-01-01

    Highlights: → Correlations arising from the maxima of products of properties in the coexistence line. → Analysis of maxima along the vapor pressure curve. → Correlations for the maximum of the saturated vapor enthalpy curve. → Prediction of properties of the new low GWP refrigerants HFO 1234yf and HFO 1234ze (E). - Abstract: In this work we analyze correlations for the maxima of products of some liquid-vapor saturation properties. These points define new characteristic properties of each fluid that are shown to exhibit linear correlations with the critical properties. We also demonstrate that some of these properties are well correlated with the acentric factor. An application is made to predict the properties of two new low global warming potential (GWP) refrigerants.

  15. Rectifiability of Line Defects in Liquid Crystals with Variable Degree of Orientation

    Science.gov (United States)

    Alper, Onur

    2018-04-01

    In [2], H ardt, L in and the author proved that the defect set of minimizers of the modified Ericksen energy for nematic liquid crystals consists locally of a finite union of isolated points and Hölder continuous curves with finitely many crossings. In this article, we show that each Hölder continuous curve in the defect set is of finite length. Hence, locally, the defect set is rectifiable. For the most part, the proof closely follows the work of D e L ellis et al. (Rectifiability and upper minkowski bounds for singularities of harmonic q-valued maps, arXiv:1612.01813, 2016) on harmonic Q-valued maps. The blow-up analysis in A lper et al. (Calc Var Partial Differ Equ 56(5):128, 2017) allows us to simplify the covering arguments in [11] and locally estimate the length of line defects in a geometric fashion.

  16. Numerical method of lines for the relaxational dynamics of nematic liquid crystals.

    Science.gov (United States)

    Bhattacharjee, A K; Menon, Gautam I; Adhikari, R

    2008-08-01

    We propose an efficient numerical scheme, based on the method of lines, for solving the Landau-de Gennes equations describing the relaxational dynamics of nematic liquid crystals. Our method is computationally easy to implement, balancing requirements of efficiency and accuracy. We benchmark our method through the study of the following problems: the isotropic-nematic interface, growth of nematic droplets in the isotropic phase, and the kinetics of coarsening following a quench into the nematic phase. Our results, obtained through solutions of the full coarse-grained equations of motion with no approximations, provide a stringent test of the de Gennes ansatz for the isotropic-nematic interface, illustrate the anisotropic character of droplets in the nucleation regime, and validate dynamical scaling in the coarsening regime.

  17. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Liquid and gaseous wastes from pressurised water reactors: International comparison

    International Nuclear Information System (INIS)

    Benedittini, M.

    1989-04-01

    This report presents the main results of a comparison on radioactive effluents releases from ninety-four PWRs in the following countries: Belgium, Federal Republic of Germany, France, Japan, Sweden, Switzerland and the United States. For liquid releases, distinctions have been undertaken between tritium and no tritium activities and for gaseous releases between noble gases and halogens-aerosols. Data have been collected from literature published or by contacting utilities responsible or authorities in order to constitute a data bank. However for the comparison, reactors for which commercial operation starts before July 1974, have been excluded. As far as the main comparative results are concerned, the averages of tritium activity per energy production unit for liquid releases are ranging between 1840 GBq/TWh and 3000 GBq/TWh and two groups of countries may be noted: those for which the results are around 2000 GBq/TWh as Frg, Japan and Switzerland and those which have an activity level around 3000 GBq/TWh as Belgium, France and Sweden. The United States are between these two groups. A factor which may provide an explanation for these discrepancies concerns practices for primary circuit: recycling it, leads to a lower tritium activity for releases and to a higher tritium activity concentration in the primary circuit. Excluding tritium, mean liquid activities per reactor are widely varying from one country to another: - lower than 0,05 GBq in Japan and in Switzerland; - from one thousand to two thousand times higher in France, Sweden and the United States. Discrepancies for gaseous activities are narrower: a factor of 40 in noble gases activities and a factor of 25 for halogens and aerosols activities. In conclusion, for activities of the tritium liquid as well as activities of all other types of radionuclides, countries can be shared in two groups according the activity level - For the lowest: FRG, Japan and Switzerland; - For the highest: Belgium, France and Sweden

  20. Liquid and gaseous wastes from pressurised water reactors: international comparison

    International Nuclear Information System (INIS)

    Benedittini, M.

    1989-04-01

    This report presents the main results of a comparison on radioactive effluents releases from ninety-four PWRs in the following countries: Belgium, Federal Republic of Germany, France, Japan, Sweden, Switzerland and the United States. For liquid releases, distinctions have been undertaken between tritium and no tritium activities and for gaseous releases between noble gases and halogens-aerosols. Data have been collected from literature published or by contacting utilities responsible or authorities in order to constitute a data bank. However for the comparison, reactors for which commercial operation starts before July 1974, have been excluded. As far as the main comparative results are concerned, the averages of tritium activity per energy production unit for liquid releases are ranging between 1840 GBq/TWh and 3000 GBq/TWh and two groups of countries may be noted: those for which the results are around 2000 GBq/TWh as FRG, Japan and Switzerland and those which have an activity level around 3000 GBq/TWh as Belgium, France and Sweden. The United States are between these two groups. A factor which may provide an explanation for these discrepancies concerns practices for primary circuit: recycling it, leads to a lower tritium activity for releases and to a higher tritium activity concentration in the primary circuit. Excluding tritium, mean liquid activities per reactor are widely varying from one country to another: - lower than 0,05 GBq in Japan and in Switzerland; - from one thousand to two thousand times higher in France, Sweden and the United States. Discrepancies for gaseous activities are narrower: a factor of 40 in noble gases activities and a factor of 25 for halogens and aerosols activities. In conclusion, for activities of the tritium liquid as well as activities of all other types of radionuclides, countries can be shared in two groups according the activity level - For the lowest: FRG, Japan and Switzerland; - For the highest: Belgium, France and Sweden

  1. Liquid-liquid phase separation in internally mixed magnesium sulfate/glutaric acid particles

    Science.gov (United States)

    Wu, Feng-Min; Wang, Xiao-Wei; Jing, Bo; Zhang, Yun-Hong; Ge, Mao-Fa

    2018-04-01

    The confocal Raman microscopy is utilized to investigate the liquid-liquid phase separation (LLPS) of mixed magnesium sulfate/glutaric acid (MgSO4/GA) droplets deposited on a hydrophobic polytetrafluoroethylene (PTFE) substrate and a hydrophilic quartz substrate. Raman spectra collected from different regions of the mixed droplets provide detailed information of component distributions for MgSO4 and GA. During the dehydration process, the MgSO4/GA mixed particles show the initial liquid-liquid phase separation between 85% and 80% relative humidity (RH) on both the hydrophobic and hydrophilic substrates. For the droplets deposited on the two substrates, the inner phase of droplets is dominated by aqueous MgSO4, which is surrounded by a rich GA organic layer due to the surface tension effects. In addition, the crystallization of GA could be observed in the organic aqueous phase while it is inhibited in the inner MgSO4 phase due to the effects of gel formation of MgSO4 at low RH. The Raman spectra reveal that with decreasing RH the morphology of the mixed droplet evolves from a uniform droplet to the structure of LLPS with the GA crystallizing in the outer layer and MgSO4 gel formed in the inner phase. These findings contribute to the further understanding of the role of interactions between inorganic salts and organic acids on the morphological evolution and environmental effects of atmospheric aerosols under ambient RH conditions.

  2. Thermodynamic analysis of a refrigeration cycle using regenerative heat exchanger - suction/liquid line

    Energy Technology Data Exchange (ETDEWEB)

    Tebchirani, Tarik Linhares; Matos, Rudmar Serafim [Pos graduate Programme in Mechanical Engineering (PGMEC), Universidade Federal do Parana, Curitiba, PR (Brazil)], e-mails: tarik@utfpr.edu.br, rudmar@demec.ufpr.br

    2010-07-01

    This paper presents results from thermodynamic comparison of a conventional compression cycle and a steam cycle that uses a heat exchanger countercurrent (liquid line/suction line) in an air conditioning system split. The main objective is to study the relationship between the COP and the mass variation of refrigerant to the effectiveness of the heat exchanger. The papers presented in the literature discuss the matter in a theoretical way, are summarized in tables of rare loss statements without specification of methods. The methodology of work is based on testing of an air conditioner operating conventionally and also with the heat exchanger for the determination of values and parameters of interest. The tests were performed in a thermal chamber with temperature controlled and equipped with a data acquisition system for reading and storage results. The refrigerant was R22. Besides making possible an assessment of the feasibility of cost-benefit thermodynamics, it is suggested a different method for installing the equipment type split. (author)

  3. Internal pressure changes of liquid filled shipping casks due to thermal environment

    International Nuclear Information System (INIS)

    Jackson, J.E.

    1978-01-01

    A discussion of the significance of internal pressure calculations in liquid filled shipping casks subjected to a high temperature thermal environment is presented. Some basic thermodynamic relationships are introduced and discussed as they apply to the two-phase mixture problem encountered with liquid filled casks. A model of the liquid filled cask is developed and the assumptions and limitations of the mathematical model are discussed. A relationship is derived which can be used to determine internal cask pressures as a function of initial thermodynamic loading conditions, initial fluid volume ratio and final mixture temperature. The results for water/air filled casks are presented graphically in a parametric form. The curves presented are particularly useful for preliminary design verification purposes. A qualitative discussion of the use of the results from an error analysis aspect is presented. Some pressure calculation problems frequently seen by NRC for liquid filled cask designs are discussed

  4. Liquidity spillover in international stock markets through distinct time scales.

    Science.gov (United States)

    Righi, Marcelo Brutti; Vieira, Kelmara Mendes

    2014-01-01

    This paper identifies liquidity spillovers through different time scales based on a wavelet multiscaling method. We decompose daily data from U.S., British, Brazilian and Hong Kong stock markets indices in order to calculate the scale correlation between their illiquidities. The sample is divided in order to consider non-crisis, sub-prime crisis and Eurozone crisis. We find that there are changes in correlations of distinct scales and different periods. Association in finest scales is smaller than in coarse scales. There is a rise on associations in periods of crisis. In frequencies, there is predominance for significant distinctions involving the coarsest scale, while for crises periods there is predominance for distinctions on the finest scale.

  5. Verification of Remote Inspection Techniques for Reactor Internal Structures of Liquid Metal Reactor

    International Nuclear Information System (INIS)

    Joo, Young Sang; Lee, Jae Han

    2007-02-01

    The reactor internal structures and components of a liquid metal reactor (LMR) are submerged in hot sodium of reactor vessel. The division 3 of ASME code section XI specifies the visual inspection as major in-service inspection (ISI) methods of reactor internal structures and components. Reactor internals of LMR can not be visually examined due to opaque liquid sodium. The under-sodium viewing techniques using an ultrasonic wave should be applied for the visual inspection of reactor internals. Recently, an ultrasonic waveguide sensor with a strip plate has been developed for an application to the under-sodium inspection. In this study, visualization technique, ranging technique and monitoring technique have been suggested for the remote inspection of reactor internals by using the waveguide sensor. The feasibility of these remote inspection techniques using ultrasonic waveguide sensor has been evaluated by an experimental verification

  6. Verification of Remote Inspection Techniques for Reactor Internal Structures of Liquid Metal Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Young Sang; Lee, Jae Han

    2007-02-15

    The reactor internal structures and components of a liquid metal reactor (LMR) are submerged in hot sodium of reactor vessel. The division 3 of ASME code section XI specifies the visual inspection as major in-service inspection (ISI) methods of reactor internal structures and components. Reactor internals of LMR can not be visually examined due to opaque liquid sodium. The under-sodium viewing techniques using an ultrasonic wave should be applied for the visual inspection of reactor internals. Recently, an ultrasonic waveguide sensor with a strip plate has been developed for an application to the under-sodium inspection. In this study, visualization technique, ranging technique and monitoring technique have been suggested for the remote inspection of reactor internals by using the waveguide sensor. The feasibility of these remote inspection techniques using ultrasonic waveguide sensor has been evaluated by an experimental verification.

  7. IPL's entry into international liquids pipelining is instructive

    International Nuclear Information System (INIS)

    Wishart, D.M.

    1995-01-01

    This paper reviews the steps taken by IPL Energy to develop international operations. It reviews the management initiatives that must be in-place to successfully purchase operate oil and gas pipelines in foreign countries. It discusses the business and development costs; it describes criteria for selecting projects for development including the rate of equity investment required; risk management and mitigation options; and human resources

  8. Determination of vitamin K homologues by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection

    International Nuclear Information System (INIS)

    Ahmed, Sameh; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2007-01-01

    A sensitive and highly selective high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K homologues including phylloquinone (PK), menaquinone-4 (MK-4) and menaquinone-7 (MK-7) in human plasma using post-column peroxyoxalate chemiluminescence (PO-CL) detection following on-line ultraviolet (UV) irradiation. The method was based on ultraviolet irradiation (254 nm, 15 W) of vitamin K to produce hydrogen peroxide and a fluorescent product at the same time, which can be determined with PO-CL detection. The separation of vitamin K by HPLC was accomplished isocratically on an ODS column within 35 min. The method involves the use of 2-methyl-3-pentadecyl-1,4-naphthoquinone as an internal standard. The detection limits (signal-to-noise ratio = 3) were 32, 38 and 85 fmol for PK, MK-4 and MK-7, respectively. The recoveries of PK, MK-4 and MK-7 were greater than 82% and the inter- and intra-assay R.S.D. values were 1.9-5.4%. The sensitivity and selectivity of this method were sufficient for clinical and nutritional applications

  9. Low-Z internal target from a cryogenically cooled liquid microjet source

    Energy Technology Data Exchange (ETDEWEB)

    Kuehnel, M.; Petridis, N. [Institut fuer Kernphysik, J.W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt (Germany); Winters, D.F.A. [GSI, Planckstr. 1, 64291 (Germany); Physikalisches Institut, Ruprecht-Karls-Universitaet, Philosophenweg 12, 69120 Heidelberg (Germany); Popp, U. [GSI, Planckstr. 1, 64291 (Germany); Doerner, R. [Institut fuer Kernphysik, J.W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt a. M. (Germany); Stoehlker, Th. [GSI, Planckstr. 1, 64291 (Germany); Physikalisches Institut, Ruprecht-Karls-Universitaet, Philosophenweg 12, 69120 Heidelberg (Germany); Grisenti, R.E. [Institut fuer Kernphysik, J.W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt (Germany); GSI, Planckstr. 1, 64291 (Germany)], E-mail: grisenti@atom.uni-frankfurt.de

    2009-04-21

    We carried out an extensive investigation on the production of cryogenically cooled liquid hydrogen and helium droplet beams at the experimental storage ring at GSI with the goal to achieve high area densities for these low-Z internal targets. Our results show that an area density of up to 10{sup 14}cm{sup -2} is achieved for both light gases by expanding the liquid through sub-10 {mu}m diameter nozzles. The achieved area density is comparable with the previous results for the hydrogen internal target and represents an improvement by about four orders of magnitude for the helium target.

  10. Low-Z internal target from a cryogenically cooled liquid microjet source

    International Nuclear Information System (INIS)

    Kuehnel, M.; Petridis, N.; Winters, D.F.A.; Popp, U.; Doerner, R.; Stoehlker, Th.; Grisenti, R.E.

    2009-01-01

    We carried out an extensive investigation on the production of cryogenically cooled liquid hydrogen and helium droplet beams at the experimental storage ring at GSI with the goal to achieve high area densities for these low-Z internal targets. Our results show that an area density of up to 10 14 cm -2 is achieved for both light gases by expanding the liquid through sub-10 μm diameter nozzles. The achieved area density is comparable with the previous results for the hydrogen internal target and represents an improvement by about four orders of magnitude for the helium target.

  11. 76 FR 25576 - Pipeline Safety: Applying Safety Regulations to All Rural Onshore Hazardous Liquid Low-Stress Lines

    Science.gov (United States)

    2011-05-05

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... to All Rural Onshore Hazardous Liquid Low-Stress Lines AGENCY: Pipeline and Hazardous Materials..., suggested that the scope should include low-stress gas pipelines such as those associated with coal bed...

  12. Maximizing the peak production rate in off-line comprehensive two-dimensional liquid chromatography with mass spectrometry detection

    NARCIS (Netherlands)

    Eeltink, S.; Dolman, S.; Ursem, M.; Swart, R.; McLeod, F.; Schoenmakers, P.J.

    2009-01-01

    This article describes an optimization strategy to obtain the best possible performance in the shortest analysis time—called the peak production rate—for comprehensive off-line two-dimensional liquid chromatography. The demands on column technology (particle size and column length) and LC conditions

  13. Application and recovery of ionic liquids in the preparative separation of four flavonoids from Rhodiola rosea by on-line three-dimensional liquid chromatography.

    Science.gov (United States)

    Ma, Shufeng; Hu, Liming; Ma, Chaoyang; Lv, Wenping; Wang, Hongxin

    2014-09-01

    A novel on-line three-dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1-butyl-3-methylimidazolium chloride aqueous solution was selected as the solvent system. In the first-dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second-dimension high-speed countercurrent chromatographic column for separation. In the third-dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1, 20.4 mg of compound 2, 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic-liquid-based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, Scott J.; Lin, Kuo-Cheng; Carter, Campbell D.; Kastengren, Alan L.

    2017-08-02

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through x-ray radiography and x-ray fluorescence. An inside-out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an x-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low x-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength (EPL) and line-of-sight averaged density ρ(y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveal a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry.

  15. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, Scott J. [Aerospace Systems Directorate, Air Force Research Laboratory, Arnold AFB, TN (United States); Lin, Kuo-Cheng [Taitech, Inc., Beavercreek, OH (United States); Carter, Campbell D. [Aerospace Systems Directorate, Air Force Research Laboratory, Wright-Patterson AFB, OH (United States); Kastengren, Alan L. [Argonne National Laboratory, X-Ray Science Division, Advanced Photon Source, Argonne, IL (United States)

    2017-09-15

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through X-ray radiography and X-ray fluorescence. An inside-out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an X-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low X-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength and line-of-sight averaged density ρ(y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveals a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry. (orig.)

  16. Silver Lining in Changing International Situation——An overall review of international situation in 2003

    Institute of Scientific and Technical Information of China (English)

    YuHongjun; SongZhengben

    2004-01-01

    The year 2003 witnessed a still complicated international situation in which the process of transition from an old pattern to a new pattern and from an old order to a new order was conspicuously difficult and tortuous. We could say that “one theme”, “two mainscourges”, “three postures”,

  17. KINEMATIC ANALYSIS OF LINE-OUT THROWING IN ELITE INTERNATIONAL RUGBY UNION

    Directory of Open Access Journals (Sweden)

    Mark G.L. Sayers

    2011-09-01

    Full Text Available The rugby union line-out is a key aspect of game play and involves players from both teams contesting for the ball after it has been thrown in from the side line. Successful lines-out throws require the ball to be delivered accurately to the hands of a jumping and/or lifted team mate (approximately 3-3.5 m off the ground over distances of between 5- 18 m. Previous research has suggested considerable inter and intra-individual differences in the throwing techniques of international level players. Accordingly, this project investigated the interrelationships between accuracy and the line-out throwing characteristics of three elite international rugby players, and then analyzed whether these changed for throws over increasing length. Three-dimensional (3D data were developed from video footage (50 Hz of three elite international subjects for 30 throws over three distances (6 m, 10 m, and 15 m. Results showed notable differences between subjects in many variables at each of the key throw phases. However, several variables such as the degree of trunk flexion at the end of the backswing and at ball release, coupled with elbow flexion angle at ball release remained constant as throw length increased. All subjects exhibited high levels of consistency in movement patterns across all throw lengths. Findings indicated that these high performance line-out throwers shared several common characteristics that will provide useful guides in the development of training programs

  18. In-line ATR-UV and Raman Spectroscopy for Monitoring API Dissolution Process During Liquid-Filled Soft-Gelatin Capsule Manufacturing.

    Science.gov (United States)

    Wan, Boyong; Zordan, Christopher A; Lu, Xujin; McGeorge, Gary

    2016-10-01

    Complete dissolution of the active pharmaceutical ingredient (API) is critical in the manufacturing of liquid-filled soft-gelatin capsules (SGC). Attenuated total reflectance UV spectroscopy (ATR-UV) and Raman spectroscopy have been investigated for in-line monitoring of API dissolution during manufacturing of an SGC product. Calibration models have been developed with both techniques for in-line determination of API potency. Performance of both techniques was evaluated and compared. The ATR-UV methodology was found to be able to monitor the dissolution process and determine the endpoint, but was sensitive to temperature variations. The Raman technique was also capable of effectively monitoring the process and was more robust to the temperature variation and process perturbations by using an excipient peak for internal correction. Different data preprocessing methodologies were explored in an attempt to improve method performance.

  19. Do Internal and external environmental management contribute to the triple bottom line?

    NARCIS (Netherlands)

    De Giovanni, P.

    2012-01-01

    Purpose: The purpose of this paper is to investigate the effect of both internal and external environmental management (EM) on the triple bottom line (TBL), which embraces environmental, economic, and social performance. Both direct and indirect effects are estimated in order to capture the overall

  20. IR finite one-loop box scalar integral with massless internal lines

    International Nuclear Information System (INIS)

    Duplancic, G.; Nizic, B.

    2002-01-01

    The IR finite one-loop box scalar integral with massless internal lines has been recalculated. The result is very compact, simple and valid for arbitrary values of the relevant kinematic variables. It is given in terms of only two dilogarithms and a few logarithms, all of very simple arguments. (orig.)

  1. Milking liquid nano-droplets by an IR laser: a new modality for the visualization of electric field lines

    International Nuclear Information System (INIS)

    Vespini, Veronica; Coppola, Sara; Grilli, Simonetta; Paturzo, Melania; Ferraro, Pietro

    2013-01-01

    Liquid handling at micron- and nano-scale is of paramount importance in many fields of application such as biotechnology and biochemistry. In fact, the microfluidics technologies play an important role in lab-on-a-chip devices and, in particular, the dispensing of liquid droplets is a required functionality. Different approaches have been developed for manipulating, dispensing and controlling nano-droplets under a wide variety of configurations. Here we demonstrate that nano-droplets can be drawn from liquid drop or film reservoirs through a sort of milking effect achieved by the absorption of IR laser radiation into a pyroelectric crystal. The generation of the pyroelectric field induced by the IR laser is calculated numerically and a specific experiment has been designed to visualize the electric field stream lines that are responsible for the liquid milking effect. The experiments performed are expected to open a new route for the visualization, measure and characterization procedures in the case of electrohydrodynamic applications. (paper)

  2. Fluctuating dynamics of nematic liquid crystals using the stochastic method of lines

    Science.gov (United States)

    Bhattacharjee, A. K.; Menon, Gautam I.; Adhikari, R.

    2010-07-01

    We construct Langevin equations describing the fluctuations of the tensor order parameter Qαβ in nematic liquid crystals by adding noise terms to time-dependent variational equations that follow from the Ginzburg-Landau-de Gennes free energy. The noise is required to preserve the symmetry and tracelessness of the tensor order parameter and must satisfy a fluctuation-dissipation relation at thermal equilibrium. We construct a noise with these properties in a basis of symmetric traceless matrices and show that the Langevin equations can be solved numerically in this basis using a stochastic version of the method of lines. The numerical method is validated by comparing equilibrium probability distributions, structure factors, and dynamic correlations obtained from these numerical solutions with analytic predictions. We demonstrate excellent agreement between numerics and theory. This methodology can be applied to the study of phenomena where fluctuations in both the magnitude and direction of nematic order are important, as for instance, in the nematic swarms which produce enhanced opalescence near the isotropic-nematic transition or the problem of nucleation of the nematic from the isotropic phase.

  3. Proceedings of the 9. international symposium on power-line communications and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Lampe, L. (comp.) [British Columbia Univ., Vancouver, BC (Canada). Dept. of Electrical and Computer Engineering

    2005-07-01

    The 2005 International Symposium on Power Line Communications and Its Applications (ISPLC 2005) is the leading international scientific conference on technology and applications for communication over power lines. The conference addresses the latest technological advances in power-line communications and current and future applications of power-line communication systems including broadband Internet access, indoor home networking, power-line based communications in vehicles, power-line control networks, and automatic meter reading systems. Specific conference papers included measurements, channel characterization and modeling; standards and regulations; electromagnetic compatibility; information and communication theory; modulation and error-control coding techniques; single carrier, OFDM, and spread spectrum techniques; detection, estimation, and iterative processing techniques; signal processing algorithms and devices; multiple-access techniques; modem and LSI design; networks and protocols; system architectures; automatic meter reading systems; applications and services; and, experimental systems and field trials. A total of 90 papers were featured and organized into 14 regular sessions and one poster session. Seven of these presentations have been catalogued separately for inclusion in this database. In addition to the technical program, 3 keynotes speeches and 2 panel discussions were presented and chaired by distinguished speakers and moderators. tabs., figs.

  4. Combustion of Liquid Bio-Fuels in an Internal Circulating Fluidized Bed

    Czech Academy of Sciences Publication Activity Database

    Miccio, F.; Kalisz, S.; Baxter, D.; Svoboda, Karel

    2008-01-01

    Roč. 143, 1-3 (2008), s. 172-179 ISSN 1385-8947 Institutional research plan: CEZ:AV0Z40720504 Keywords : internal circulating fluidized bed * liquid fuel * combustion Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.813, year: 2008

  5. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Rapid grounding line migration induced by internal variability of a marine-terminating ice stream

    Science.gov (United States)

    Robel, A.; Schoof, C.; Tziperman, E.

    2013-12-01

    Numerous studies have found significant variability in the velocity of ice streams to be a prominent feature of geomorphologic records in the Siple Coast (Catania et al. 2012) and other regions in West Antarctica (Dowdeswell et al. 2008). Observations indicate that grounding line position is strongly influenced by ice stream variability, producing rapid grounding line migration in the recent past (Catania et al. 2006) and the modern (Joughin & Tulaczyk 2002). We analyze the interaction of grounding line mass flux and position in a marine-terminating ice stream using a stretch-coordinate flowline model. This model is based on that described in Schoof (2007), with a mesh refined near the grounding line to ensure accurate resolution of the mechanical transition zone. Here we have added lateral shear stress (Dupont & Alley 2005) and an undrained plastic bed (Tulaczyk et al. 2000). The parameter dependence of ice stream variability seen in this model compares favorably to both simpler (Robel et al. 2013) and more complex (van der Wel et al. 2013) models, though with some key differences. We find that thermally-induced internal ice stream variability can cause very rapid grounding line migration even in the absence of retrograde bed slopes or external forcing. Activation waves propagate along the ice stream length and trigger periods of rapid grounding line migration. We compare the behavior of the grounding line due to internal ice stream variability to changes triggered externally at the grounding line such as the rapid disintegration of buttressing ice shelves. Implications for Heinrich events and the Marine Ice Sheet Instability are discussed.

  7. Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line

    Science.gov (United States)

    Gaul, Christopher J.

    2001-01-01

    The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

  8. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) has expressed a need for an on-line, real-time instrument for assaying alpha-emitting radionuclides (uranium and the transuranics) in effluent waters leaving DOE sites to ensure compliance with regulatory limits. Due to the short range of alpha particles in water (approximately40 Tm), it is necessary now to intermittently collect samples of water and send them to a central laboratory for analysis. A lengthy and costly procedure is used to separate and measure the radionuclides from each sample. Large variations in radionuclide concentrations in the water may go undetected due to the sporadic sampling. Even when detected, the reading may not be representative of the actual stream concentration. To address these issues, Tecogen, a division of Thermo Power Corporation, a Thermo Electron company, is developing a real-time, field-deployable, alpha monitor based on a solid-state silicon wafer semiconductor (patent pending, to be assigned to the Department of Energy). The Thermo Alpha Monitor (TAM) will serve to monitor effluent water streams (Subsurface Contaminants Focus Area) and will be suitable for process control of remediation as well as decontamination and decommissioning operations, such as monitoring scrubber or rinse water radioactivity levels (Mixed Waste Focus Area and D and D Focus Area). It would be applicable for assaying other liquids, such as oil, or solids after proper preconditioning. Rapid isotopic alpha air monitoring is also possible using this technology. This instrument for direct counting of alpha-emitters in aqueous streams is presently being developed by Thermo Power under a development program funded by the DOE Environmental Management program (DOE-EM), administered by the Morgantown Energy Technology Center (METC). Under this contract, Thermo Power has demonstrated a solid-state, silicon-based semiconductor instrument, which uses a proprietary film-based collection system to quantitatively extract the

  9. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    International Nuclear Information System (INIS)

    Owen, Andrew W.; McAulay, Edith A.J.; Nordon, Alison; Littlejohn, David; Lynch, Thomas P.; Lancaster, J. Steven; Wright, Robert G.

    2014-01-01

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min −1 , respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate

  10. Insulin receptor internalization defect in an insulin-resistant mouse melanoma cell line

    International Nuclear Information System (INIS)

    Androlewicz, M.J.; Straus, D.S.; Brandenburg, D.F.

    1989-01-01

    Previous studies from this laboratory demonstrated that the PG19 mouse melanoma cell line does not exhibit a biological response to insulin, whereas melanoma x mouse embryo fibroblast hybrids do respond to insulin. To investigate the molecular basis of the insulin resistance of the PG19 melanoma cells, insulin receptors from the insulin-resistant melanoma cells and insulin-sensitive fibroblast x melanoma hybrid cells were analyzed by the technique of photoaffinity labeling using the photoprobe 125 I-NAPA-DP-insulin. Photolabeled insulin receptors from the two cell types have identical molecular weights as determined by SDS gel electrophoresis under reducing and nonreducing conditions, indicating that the receptors on the two cell lines are structurally similar. Insulin receptor internalization studies revealed that the hybrid cells internalize receptors to a high degree at 37 degree C, whereas the melanoma cells internalize receptors to a very low degree or not at all. The correlation between ability to internalize insulin receptors and sensitivity to insulin action in this system suggests that uptake of the insulin-receptor complex may be required for insulin action in these cells. Insulin receptors from the two cell lines autophosphorylate in a similar insulin-dependent manner both in vitro and in intact cells, indicating that insulin receptors on the melanoma and hybrid cells have functional tyrosine protein kinase activity. Therefore, the block in insulin action in the PG19 melanoma cells appears to reside at a step beyond insulin-stimulated receptor autophosphorylation

  11. 3-D modeling of parietal liquid films in internal combustion engines; Modelisation tridimensionnelle des films liquides parietaux dans les moteurs a combustion interne

    Energy Technology Data Exchange (ETDEWEB)

    Foucart, H

    1998-12-11

    To simulate the air-fuel mixing in the intake ports and cylinder of an internal combustion engines, a wall fuel liquid film model has been developed for integration in 3D CFD codes. Phenomena taken into account include wall film formation by an impinging spray without splashing effect, film transport such as governed by mass and momentum equations with hot wall effects, and evaporation considering energy equation with an analytical mass transfer formulation developed here. A continuous-fluid method is used to describe the wall film over a three dimensional complex surface. The basic approximation is that of a laminar incompressible boundary layer; the liquid film equations are written in an integral form and solved by a first-order ALE finite volume scheme; the equation system is closed without coefficient fitting requirements. The model has been implemented in a Multi-Block version of KIVA-II (KMB) and tested against problems having theoretical solutions. Then in a first step, it has been compared to the measurements obtained in a cylindrical pipe reproducing the main characteristics of SI engine intake pipe flow and in a second step, it has been compared to the Xiong experiment concerning the film evaporation on a hot wall. The film behaviour is satisfactory reproduced by the computations for a set of operating conditions. Finally, engine calculations were conducted showing the importance of including a liquid film model for the simulations. (author) 54 refs.

  12. Reconnaissance survey of the intermediate-level liquid waste transfer line between X-10 and the hydrofracture site

    International Nuclear Information System (INIS)

    Duguid, J.O.; Sealand, O.M.

    1975-08-01

    Two leakage points on an intermediate-level liquid waste line were located. The waste line is used periodically to transfer waste between X-10 and the hydrofracture site. The first leak occurred prior to this survey and had been repaired, but no contaminated soil had been removed. The second leak resulted in soil contamination that was more intense than at the first leak. Analyses of soil samples taken from both locations are given in this report. Groundwater data indicate the effectiveness of the removal of the contaminated material from leak two. 1 ref., 5 figs., 3 tabs

  13. Reconnaissance survey of the intermediate level liquid waste transfer line between X-10 and the hydrofracture site

    International Nuclear Information System (INIS)

    Duguid, J.O.; Sealand, O.M.

    1975-08-01

    Two leakage points on an intermediate-level liquid waste line were located. The waste line is used periodically to transfer waste between X-10 and the hydrofracture site. The first leak had occurred prior to this survey and had been repaired. However, no contaminated soil had been removed. The second leak had not been discovered previously and soil contamination in this area was more intense than at the first leak. Analyses of soil samples taken from both locations are given in this report. Groundwater data that indicate the effectiveness of the removal of the contaminated material from leak two are presented. (U.S.)

  14. Thermal-hydraulic optimization of flexible transfer lines for liquid helium; Thermohydraulische Optimierung flexibler Transferleitungen fuer Fluessighelium

    Energy Technology Data Exchange (ETDEWEB)

    Dittmar, Nico; Haberstroh, Christoph; Hesse, U. [Technische Univ. Dresden (Germany). Bitzer-Stiftungsprofessur fuer Kaelte-, Kryo- und Kompressorentechnik; Wolfram, M.; Krzyzowski, M.; Raccanelli, A. [CryoVac Gesellschaft fuer Tieftemperaturtechnik mbH und Co. KG, Troisdorf (Germany)

    2014-07-01

    Cooling systems and applications at very low temperatures are based on the use of liquid helium as cryogenic agent; the normal boiling temperature of helium-4 is 4.2 K. Due to the restricted economic production possibilities and the high energetic expenditure for helium liquefaction an efficient and sustainable handling with the resources is recommended. In university facilities the liquid helium is usually stored in containers and filled into smaller containers for transport using cryogenic transfer lines. This procedure can cause 20% loss by evaporation due to heat input and friction pressure losses. The gaseous helium has to be collected for re-liquefaction. The contribution shows that using systematic measurements an increase of the transfer rate and the efficiency of the helium filling system can be reached by a modified transfer line design.

  15. Analysis of natural convection heat transfer and flows in internally heated stratified liquid pools

    International Nuclear Information System (INIS)

    Gubaidullin, A.A. Jr.; Dinh, T.N.; Sehgal, B.R.

    1999-01-01

    In this paper, natural convection flows and heat transfer in a liquid pool, with two superposed immiscible fluid layers, are analyzed. The objective of the study is to examine the effect of interfacial hydrodynamics and to develop a method which enables energy splitting to be evaluated in a stratified liquid pool. The thermal convection, with and without an internal heat source, in a rectangular cavity with different pairs of fluids was numerically simulated by a CFD code FLOW-3D. It was found that the code performs very well for prediction of heat transfer coefficients for different conditions. The hydrodynamic coupling between immiscible layers was found to have minor, if any, impact on the natural convection heat transfer for the conditions examined. Calculated results were used to develop, and validate, a new correlation for energy splitting and for heat transfer in stratified liquid pools

  16. Effect of injector geometry on the performance of an internally mixed liquid atomizer

    Energy Technology Data Exchange (ETDEWEB)

    Kushari, A.

    2010-11-15

    This paper presents the results of an experimental study of the effect of injector's geometry on the performance of an internally mixed, air-assisted, liquid injector. In this type of injector a small amount of air is injected into a liquid stream within the injector. The interaction of the liquid with the atomizing air inside the injector induces atomization. The results presented in this paper show that the size of the droplets produced by the investigated injector decreases with a decrease in the air injection area. This is due to the increase in atomizing air injection velocity that accompanies the decrease in the air injection area, which improves atomization. This study also shows that the droplet sizes decrease with an increase in the injector's length, which is attributed to the increase in total interactive force. (author)

  17. Fraction transfer process in on-line comprehensive two-dimensional liquid phase separations

    Czech Academy of Sciences Publication Activity Database

    Česla, P.; Křenková, Jana

    2017-01-01

    Roč. 40, č. 1 (2017), s. 109-123 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA14-06319S Institutional support: RVO:68081715 Keywords : capillary electrophoresis * comprehensive liquid chromatography * fraction transfer * two-dimensional separations * liquid chromatography Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.557, year: 2016

  18. Bioanalytical Applications of Fluorescence Line-Narrowing and Non-Line-Narrowing Spectroscopy Interfaced with Capillary Electrophoresis and High-Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Kenneth Paul [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) are widely used analytical separation techniques with many applications in chemical, biochemical, and biomedical sciences. Conventional analyte identification in these techniques is based on retention/migration times of standards; requiring a high degree of reproducibility, availability of reliable standards, and absence of coelution. From this, several new information-rich detection methods (also known as hyphenated techniques) are being explored that would be capable of providing unambiguous on-line identification of separating analytes in CE and HPLC. As further discussed, a number of such on-line detection methods have shown considerable success, including Raman, nuclear magnetic resonance (NMR), mass spectrometry (MS), and fluorescence line-narrowing spectroscopy (FLNS). In this thesis, the feasibility and potential of combining the highly sensitive and selective laser-based detection method of FLNS with analytical separation techniques are discussed and presented. A summary of previously demonstrated FLNS detection interfaced with chromatography and electrophoresis is given, and recent results from on-line FLNS detection in CE (CE-FLNS), and the new combination of HPLC-FLNS, are shown.

  19. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    The US Department of Energy (DOE) has expressed a need for an on-line, real-time instrument for assaying alpha-emitting radionuclides (uranium and the transuranics) in effluent waters leaving DOE sites to ensure compliance with regulatory limits. Due to the short range of alpha particles in water (approximately40 Im), it is necessary now to intermittently collect samples of water and send them to a central laboratory for analysis. A lengthy and costly procedure is used to separate and measure the radionuclides from each sample. Large variations in radionuclide concentrations in the water may go undetected due to the sporadic sampling. Even when detected, the reading may not be representative of the actual stream concentration. To address these issues, the Advanced Technologies Group of Thermo Power Corporation (a Thermo Electron company) is developing a real-time, field-deployable alpha monitor based on a solid-state silicon wafer semiconductor (US Patent 5,652,013 and pending, assigned to the US Department of Energy). The Thermo Water Alpha Monitor will serve to monitor effluent water streams (Subsurface Contaminants Focus Area) and will be suitable for process control of remediation as well as decontamination and decommissioning (D and D) operations, such as monitoring scrubber or rinse water radioactivity levels (Mixed Waste, Plutonium, and D and D Focus Area). It would be applicable for assaying other liquids, such as oil, or solids after proper preconditioning. Rapid isotopic alpha air monitoring is also possible using this technology. This report details the program's accomplishments to date. Most significantly, the Alpha Monitoring Instrument was successfully field demonstrated on water 100X below the Environmental Protection Agency's proposed safe drinking water limit--down to under 1 pCi/1. During the Field Test, the Alpha Monitoring Instrument successfully analyzed isotopic uranium levels on a total of five different surface water, process water, and

  20. On-Line Ion Exchange Liquid Chromatography as a Process Analytical Technology for Monoclonal Antibody Characterization in Continuous Bioprocessing.

    Science.gov (United States)

    Patel, Bhumit A; Pinto, Nuno D S; Gospodarek, Adrian; Kilgore, Bruce; Goswami, Kudrat; Napoli, William N; Desai, Jayesh; Heo, Jun H; Panzera, Dominick; Pollard, David; Richardson, Daisy; Brower, Mark; Richardson, Douglas D

    2017-11-07

    Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.

  1. A static analytical apparatus for vapour pressures and (vapour + liquid) phase equilibrium measurements with an internal stirrer and view windows

    International Nuclear Information System (INIS)

    Guo, Hao; Gong, Maoqiong; Dong, Xueqiang; Wu, Jianfeng

    2014-01-01

    Highlights: • A new static analytical apparatus for vapour pressures and VLE data was designed. • The {R600a + R245fa} system was selected as a verification system. • Correlation of VLE data was made using PRvdWs and PRHVNRTL model. • Good agreement can be found with the literature data. - Abstract: A new static analytical apparatus for reliable vapour pressures and (vapour + liquid) equilibrium data of small-scale cell (≈150 mL) with internal stirrer and view windows was designed. In this work, the compositions of the phases were analyzed by a gas chromatograph connected on-line with TCD detectors. The operating pressure ranges from (0 to 3000) kPa, and the operating temperature range from (293 to 400) K. Phase equilibrium data for previously reported systems were first measured to test the credibility of the newly developed apparatus. The test included vapour pressure of 1,1,1,3,3-pentafluoropropane (R245fa) and isobutane (R600a), VLE of the (R600a + R245fa) system from T = (293.150 to 343.880) K. The measured VLE data are regressed with thermodynamic models using Peng–Robinson EoS with two different models, viz. the van der Waals mixing rule, and the Huron–Vidal mixing rule utilising the non-random two-liquid activity coefficient model. Thermodynamic consistency testing is also performed for the newly measured experimental data

  2. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. The Need for Regulation of Cyber Terrorism Phenomena in Line With Principles of International Criminal Law

    Directory of Open Access Journals (Sweden)

    Enver BUÇAJ

    2017-03-01

    Full Text Available This paper scrutinizes and highlights imminent need to regulate cyber terrorism pheromone in line with principle of international law. In so doing, this paper intends to ascertain legal basis to regulate cyber terrorism at international level. It explains the normative conduct by drawing on adjustments of certain member states of European Union as well as from none-European member states. Particular attention will be given as to how Kosovo has addressed cyber terrorism within its legal framework of criminal acts. The paper also addresses practical consequences of cyber terrorism in context of cyber-attacks events in attempt to establish legal basis for its prevention and punishment of cyber criminals wherever it happens. The author articulates its arguments by examining the presumed threats as a result of cyber terrorism activities, as well as based on well-known cyber terrorist behaviors and constant literature that insinuate that cyber-attacks are imminent threats. Lastly, as there is neither a particular treaty nor State practices, the author considers of utmost importance to spell out different views and statistics alluding that the need to regulate cyber terrorism in line with principle of international criminal law is a necessity.

  4. The Need for Regulation of Cyber Terrorism Phenomena in Line With Principles of International Criminal Law

    Directory of Open Access Journals (Sweden)

    Enver Buçaj

    2017-03-01

    Full Text Available This paper scrutinizes and highlights imminent need to regulate cyber terrorism phenomena in line with the principle of international law. In so doing, this paper intends to ascertain legal basis to regulate cyber terrorism at international level. It explains the normative conduct by drawing on adjustments of certain member states of European Union as well as from none European member states. Particular attention will be given as to how Kosovo has addressed cyber terrorism within its legal framework of criminal acts. The paper also addresses practical consequences of cyber terrorism in the context of cyber attacks events in attempt to establish a legal basis for its prevention and punishment of cyber criminals wherever it happens. The author articulates its arguments by examining the presumed threats as a result of cyber terrorism activities, as well as based on well-known cyber terrorist behaviors and constant literature that insinuate that cyber attacks are imminent threats. Lastly, as there is neither a particular treaty nor State practices, the author considers of utmost importance to spell out different views and statistics alluding that the need to regulate cyber terrorism in line with principle of international criminal law is a necessity.

  5. Evaluation on operation of liquid relief valves for steam line break accidents by RELAP5/CANDU+ code

    International Nuclear Information System (INIS)

    Yang, C. Y.; Bang, Y. S.; Kim, H. J.

    2001-01-01

    A development of RELAP5/CANDU+ code for regulatory audits of accident analysis of CANDU nuclear power plants is on progress. This paper is undertaken in a procedure of a verification and validation for RELAP5/CANDU+ code by analyzing main steam line break accidents of WS 2/3/4. Following the ECC injection in sequence of the steam line breaks, the mismatch in heat transfer between the primary and the secondary systems makes pressure of the primary system instantly peaked to the open setpoint of liquid relief valves. The event sequence follows the result of WS 2/3/4 FSAR, but there is a difference in pressure transient after ECC injection. Sensitivity analysis for main factors dependent on the peak pressure such as control logics of liquid relief valves. ECC flow path and feedwater flow is performed. Because the pressure increase is continued for a long time and its peaking is high, open and close of the liquid relief valves are repeated several times, which is obviously different from those of WS 2/3/4 FSAR. As a result, it is evaluated that conservative modeling for the above variables is required in the analysis

  6. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  7. Analysis of recombinant Schistosoma mansoni antigen rSmp28 by on-line liquid chromatography-mass spectrometry combined with sodium dodecyl sulfate polyacrylamide gel electrophoresis

    NARCIS (Netherlands)

    Klarskov, K.; Roecklin, D.; Bouchon, B.; Sabatie, J.; Van Dorsselaer, A.; Bischoff, Rainer

    1994-01-01

    A recombinant Schistosoma mansoni antigen produced in Saccharomyces cerevisiae and purified by glutathione-Sepharose affinity chromatography was analyzed by tryptic peptide mapping using on-line reversed-phase high-performance liquid chromatography pneumatically assisted electrospray mass

  8. Internal Displacement Reactions in Multicomponent Oxides: Part I. Line Compounds with Narrow Homogeneity Range

    OpenAIRE

    Reddy, SNS; Leonard, DN; Wiggins, LB; Jacob, KT

    2005-01-01

    As a model of an internal displacement reaction involving a ternary oxide line compound, the following reaction was studied at 1273 K as a function of time, t: $Fe+NiTiO_3 = Ni + FeTiO_3$ Both polycrystalline and single-crystal materials were used as the starting $NiTiO_3$ oxide. During the reaction, the Ni in the oxide compound is displaced by Fe and it precipitates as a \\gamma -(Ni-Fe) alloy. The reaction preserves the starting ilmenite structure. The product oxide has a consta...

  9. On-line measurements of liquid carry-over from scrubbers using radioactive tracers

    Energy Technology Data Exchange (ETDEWEB)

    Haugan, A; Hassfjell, S [Institute for Energy Technology, Kjeller (Norway); Finborud, A [Mator, Porsgrunn (Norway)

    2004-07-01

    A method to measure liquid carry-over from scrubbers using gamma-emitting tracers is described and results from field tests at two onshore installations are presented. One water/1,2-ethanediol (MEG) and two hydrocarbon liquid (condensate) tracers have been used in the tests. One of the condensate tracers deposited to some extent inside the process pipe, while the other had a too high vapor pressure. The water/MEG tracer showed no MEG carry-over while the carry-over of MEG was documented to be considerable. (author)

  10. On-line measurements of liquid carry-over from scrubbers using radioactive tracers

    International Nuclear Information System (INIS)

    Haugan, A.; Hassfjell, S.; Finborud, A.

    2004-01-01

    A method to measure liquid carry-over from scrubbers using gamma-emitting tracers is described and results from field tests at two onshore installations are presented. One water/1,2-ethanediol (MEG) and two hydrocarbon liquid (condensate) tracers have been used in the tests. One of the condensate tracers deposited to some extent inside the process pipe, while the other had a too high vapor pressure. The water/MEG tracer showed no MEG carry-over while the carry-over of MEG was documented to be considerable. (author)

  11. Postaccident heat removal. II. Heat transfer from an internally heated liquid to a melting solid

    International Nuclear Information System (INIS)

    Faw, R.E.; Baker, L. Jr.

    1976-01-01

    Microwave heating has been used in studies of heat transfer from a horizontal layer of internally heated liquid to a melting solid. Experiments were designed to simulate heat transfer and meltthrough processes of importance in the analysis of postaccident heat removal capabilities of nuclear reactors. Glycerin, heated by 2.45-GHz microwave radiation, was used to simulate molten fuel. Paraffin wax was used to simulate a melting barrier confining the fuel. Experimentally measured heat fluxes and melting rates were consistent with a model based on downward heat transfer by conduction through a stagnant liquid layer and upward heat transfer augmented by natural convection. Melting and displacement of the barrier material occurred by upward-moving droplets randomly distributed across the melting surface. Results indicated that the melting and displacement process had no effect on the heat transfer process

  12. The international symposium on 'chemical engineering of gas-liquid-solid catalyst reactions'

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, H

    1978-06-01

    A report on the International Symposium on ''Chemical Engineering of Gas-Liquid-Solid Catalyst Reactions'', sponsored by the University of Liege (3/2-3/78), covers papers on the hydrodynamics, modeling and simulation, operating behavior, and chemical kinetics of trickle-bed reactors; scale-up of a trickle-bed reactor for hydrotreating Kuwait vacuum distillate; experimental results obtained in trickle-bed reactors for hydroprocessing atmospheric residua, hydrogenation of methylstyrene, hydrogenation of butanone, and hydrodemetallization of petroleum residua; advantages and disadvantages of various three-phase reactor types (e.g., for the liquid-phase hydrogenation of carbon monoxide to benzene, SNG, or methanol) and hydrodynamics, mass and heat transfer, and modeling of bubble columns with suspended catalysts (slurry reactors), and their applications (e.g., in SNG and fermentation processes).

  13. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of

  14. International strategies for growth : monetizing gas reserves to add value to the bottom line

    International Nuclear Information System (INIS)

    Mihaichuk, G.

    1998-01-01

    The direction taken by oil and gas companies, including TransCanada International, in their strategy for growth in global energy markets was discussed. The role that gas plays in meeting the objectives was examined and the different ways in which gas reserves and investments in the gas sector are being turned into high-performing vehicles for adding value to the bottom line were described. Deregulation of, and competition within, the gas and electric power industries are the driving factors for changes within the energy industries. Natural gas will be a winner because it is the first choice for new power generation. Many companies have entered the international playing field to take advantage of the opportunities in international markets. The problems and solutions to monetizing natural gas reserves, some of the international political issues such as regulatory uncertainty, cross-border disputes, lack of regional integration, and sanctions, and how these adverse effects may be mitigated through mergers, acquisitions, or joint ventures, are explored. 14 figs

  15. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G; Eckert, S [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  16. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G.; Eckert, S. [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  17. Structural analysis of steam generator internals following feed water main steam line break: DLF approach

    International Nuclear Information System (INIS)

    Bhasin, Vivek; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1993-01-01

    In order to evaluate the possible release of radioactivity in extreme events, some postulated accidents are analysed and studied during the design stage of Steam Generator (SG). Among the various accidents postulated, the most important are Feed Water Line Break (FWLB) and Main Steam Line Break (MSLB). This report concerns with dynamic structural analysis of SG internals following FWLB/MSLB. The pressure/drag-force time histories considered were corresponding to the conditions leading to the accident of maximum potential. The SG internals were analysed using two approaches of structural dynamics. In first approach simplified DLF method was adopted. This method yields an upper bound values of stresses and deflection. In the second approach time history analysis by Mode Superposition Technique was adopted. This approach gives more realistic results. The structure was qualified as per ASME B and PV Code SecIII NB. It was concluded that in all the components except perforated flow distribution plate, the stress values based on elastic analysis are within the limits specified by ASME Code. In case of perforated flow distribution plate during the MSLB transient the stress values based on elastic analysis are higher than the ASME Code limits. Therefore, its limit load analysis had to be done. Finally, the collapse pressure evaluated using limit load analysis was shown to be within the limits of ASME B and PV Code SecIII Nb. (author). 31 refs., 94 figs., 16 tabs

  18. Remote Inspection Techniques for Reactor Internals of Liquid Metal Reactor by using Ultrasonic Waveguide Sensor

    International Nuclear Information System (INIS)

    Joo, Young Sang; Kim, Seok Hun; Lee, Jae Han

    2006-02-01

    The primary components such as a reactor core, heat exchangers, pumps and internal structures of a liquid metal reactor (LMR) are submerged in hot sodium of reactor vessel. The division 3 of ASME code section XI specifies the visual inspection and continuous monitoring as major in-service inspection (ISI) methods of reactor internal structures. Reactor core and internal structures of LMR can not be visually examined due to an opaque liquid sodium. The under-sodium viewing and remote inspection techniques by using an ultrasonic wave should be applied for the in-service inspection of reactor internals. The remote inspection techniques using ultrasonic wave have been developed and applied for the visualization and ISI of reactor internals. The under sodium viewing technique has a limitation for the application of LMR due to the high temperature and irradiation environment. In this study, an ultrasonic waveguide sensor with a strip plate has been developed for an application to the under-sodium viewing and remote inspection. The Lamb wave propagation of a waveguide sensor has been analyzed and the zero-order antisymmetric A 0 plate wave was selected as the application mode of the sensor. The A 0 plate wave can be propagated in the dispersive low frequency range by using a liquid wedge clamped to the waveguide. A new technique is presented which is capable of steering the radiation beam angle of a waveguide sensor without a mechanical movement of the sensor assembly. The steering function of the ultrasonic radiation beam can be achieved by a frequency tuning method of the excitation pulse in the dispersive range of the A 0 mode. The technique provides an opportunity to overcome the scanning limitation of a waveguide sensor. The beam steering function has been evaluated by an experimental verification. The ultrasonic C-scanning experiments are performed in water and the feasibility of the ultrasonic waveguide sensor has been verified. The various remote inspection

  19. Design of equipment safety & reliability for an aseptic liquid food packaging line through maintenance engineering

    OpenAIRE

    Riccetti, Sauro

    2011-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. The organisation of maintenance, in the Aseptic Liquid Food (ALF) industry, represents an important management task that enables a company to pursue higher manufacturing effectiveness and improved market share. This research is concerned with the process to design and implement maintenance tasks. These two complementary processes (design and implementation) have been thought and designed to a...

  20. Jacking mechanism for upper internals structure of a liquid metal nuclear reactor

    International Nuclear Information System (INIS)

    Gillett, J.E.; Wineman, A.L.

    1983-01-01

    A jacking mechanism for raising the upper internals structure of a liquid metal nuclear reactor which jacking mechanism uses a system of gears and drive shafts to transmit force from a single motor to four mechanically synchronized ball jacks to raise and lower support columns which support the upper internals structure. The support columns each have a pin which rides in a slot in a housing fixed to the reactor head. The pin has two locking plates which can be rotated around the pin to bring the locking plates into engagement with the housing in a raised or a lowered position of the support column such that the support column is then supported by the locking plate and not by the ball screw jacks. (author)

  1. 222-S radioactive liquid waste line replacement and 219-S secondary containment upgrade, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1995-01-01

    The U.S. Department of Energy (DOE) is proposing to: (1) replace the 222-S Laboratory (222-S) radioactive liquid waste drain lines to the 219-S Waste Handling Facility (219-S); (2) upgrade 219-S by replacing or upgrading the waste storage tanks and providing secondary containment and seismic restraints to the concrete cells which house the tanks; and (3) replace the transfer lines from 219-S to the 241-SY Tank Farm. This environmental assessment (EA) has been prepared in compliance with the National Environmental Policy Act (NEPA) of 1969, as amended, the Council on Environmental Quality Regulations for Implementing the Procedural Provisions of NEPA (40 Code of Federal Regulations [CFR] 1500-1508), and the DOE Implementing Procedures for NEPA (10 CFR 1021). 222-S is used to perform analytical services on radioactive samples in support of the Tank Waste Remediation System and Hanford Site environmental restoration programs. Activities conducted at 222-S include decontamination of analytical processing and support equipment and disposal of nonarchived radioactive samples. These activities generate low-level liquid mixed waste. The liquid mixed waste is drained through pipelines in the 222-S service tunnels and underground concrete encasements, to two of three tanks in 219-S, where it is accumulated. 219-S is a treatment, storage, and/or disposal (TSD) unit, and is therefore required to meet Washington Administrative Code (WAC) 173-303, Dangerous Waste Regulations, and the associated requirements for secondary containment and leak detection. The service tunnels are periodically inspected by workers and decontaminated as necessary to maintain as low as reasonably achievable (ALARA) radiation levels. Although no contamination is reaching the environment from the service tunnels, the risk of worker exposure is present and could increase. 222-S is expected to remain in use for at least the next 30 years to serve the Hanford Site environmental cleanup mission

  2. Experimental and analytical study of natural-convection heat transfer of internally heated liquids

    International Nuclear Information System (INIS)

    Green, G.A.

    1982-08-01

    Boundary heat transfer from a liquid pool with a uniform internal heat source to a vertical or inclined boundary was investigated. The experiments were performed in an open rectangular liquid pool in which the internal heat source was generated by electrical heating. The local heat flux was measured to a boron nitride test wall which was able to be continuously inclined from vertical. Gold plated microthermocouples of 0.01 inch outside diameter were developed to measure the local surface temperature, both front and back, of the boron nitride. The local heat flux and, thus, the local heat transfer coefficient was measured at nineteen locations along the vertical axis of the test plate. A theoretical analysis of the coupled nonlinear boundary layer equations was performed. The parametric effect of the Prandtl number and the dimensionless wall temperature on the boundary heat transfer were investigated When the analytical model was used to calculate the boundary heat transfer data, agreement was achieved with the experimental data within 3% for the local heat transfer and within 2% for the average heat transfer

  3. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  4. Noble internal transport barriers and radial subdiffusion of toroidal magnetic lines

    Energy Technology Data Exchange (ETDEWEB)

    Misguich, J.H.; Reuss, J.D. [Association Euratom-CEA sur la Fusion, CEA/DSM/DRFC, 13 - Saint Paul lez Durance (France); Constantinescu, D.; Steinbrecher, G. [Association Euratom-N.A.S.T.I., Dept. of Physics, University of Craiova (Romania); Vlad, M.; Spineanu, F. [Association Euratom-N.A.S.T.I., National Institute of Laser, Plasma and Radiation Physics, Bucharest (Romania); Weyssow, B.; Balescu, R. [Association Euratom-Etat Belge sur la Fusion, Universite Libre de Bruxelles (Belgium)

    2002-02-01

    Internal transport barriers (ITB's) observed in tokamaks are described by a purely magnetic approach. Magnetic line motion in toroidal geometry with broken magnetic surfaces is studied from a previously derived Hamiltonian map in situation of incomplete chaos. This appears to reproduce in a realistic way the main features of a tokamak, for a given safety factor profile and in terms of a single parameter L representing the amplitude of the magnetic perturbation. New results are given concerning the Shafranov shift as function of L. For small values of L, closed magnetic surfaces exist (KAM tori) and island chains begin to appear on rational surfaces for higher values of L, with chaotic zones around hyperbolic points, as expected. Single trajectories of magnetic line motion indicate the persistence of a central protected plasma core, surrounded by a chaotic shell enclosed in a double-sided transport barrier. Magnetic lines which succeed to escape across this barrier begin to wander in a wide chaotic sea extending up to a very robust barrier (as long as L{<=}1). For values of L{>=}1, above the escape threshold, most magnetic lines succeed to escape out of the external barrier which has become a permeable Cantorus. Statistical analysis of a large number of trajectories, representing the evolution of a bunch of magnetic lines, indicate that the flux variable {psi} asymptotically grows in a diffuse manner as (L{sup 2}t) with a L{sup 2} scaling as expected, but that the average radial position r{sub m}(t) asymptotically grows as (L{sup 2}t){sup 1/4} while the mean square displacement around this average radius asymptotically grows in a sub-diffusive manner as (L{sup 2}t){sup 1/2}. This result shows the slower dispersion in the present incomplete chaotic regime, which is different from the usual quasilinear diffusion in completely chaotic situations. For physical times t{sub {phi}} of the order of the escape time defined by x{sub m}(t{sub {phi}}) {approx}1, the motion

  5. Noble internal transport barriers and radial subdiffusion of toroidal magnetic lines

    International Nuclear Information System (INIS)

    Misguich, J.H.; Reuss, J.D.; Constantinescu, D.; Steinbrecher, G.; Vlad, M.; Spineanu, F.; Weyssow, B.; Balescu, R.

    2002-02-01

    Internal transport barriers (ITB's) observed in tokamaks are described by a purely magnetic approach. Magnetic line motion in toroidal geometry with broken magnetic surfaces is studied from a previously derived Hamiltonian map in situation of incomplete chaos. This appears to reproduce in a realistic way the main features of a tokamak, for a given safety factor profile and in terms of a single parameter L representing the amplitude of the magnetic perturbation. New results are given concerning the Shafranov shift as function of L. For small values of L, closed magnetic surfaces exist (KAM tori) and island chains begin to appear on rational surfaces for higher values of L, with chaotic zones around hyperbolic points, as expected. Single trajectories of magnetic line motion indicate the persistence of a central protected plasma core, surrounded by a chaotic shell enclosed in a double-sided transport barrier. Magnetic lines which succeed to escape across this barrier begin to wander in a wide chaotic sea extending up to a very robust barrier (as long as L≤1). For values of L≥1, above the escape threshold, most magnetic lines succeed to escape out of the external barrier which has become a permeable Cantorus. Statistical analysis of a large number of trajectories, representing the evolution of a bunch of magnetic lines, indicate that the flux variable ψ asymptotically grows in a diffuse manner as (L 2 t) with a L 2 scaling as expected, but that the average radial position r m (t) asymptotically grows as (L 2 t) 1/4 while the mean square displacement around this average radius asymptotically grows in a sub-diffusive manner as (L 2 t) 1/2 . This result shows the slower dispersion in the present incomplete chaotic regime, which is different from the usual quasilinear diffusion in completely chaotic situations. For physical times t φ of the order of the escape time defined by x m (t φ ) ∼1, the motion appears to be super-diffusive, however, but less dangerous than

  6. Lining up device for the internal structures of a nuclear reactor vessel

    International Nuclear Information System (INIS)

    Silverblatt, B.L.

    1977-01-01

    The invention concerns a nuclear reactor of the type with a vessel, a vessel head carried at the top of this vessel by a core cylinder comprising a flange internally supported by the vessel, and an upper support structure supported between the core cylinder flange and the vessel head to align laterally the head, vessel, flange and support structure. A bottom key device is provided for lining up the flange, support structure and vessel, and an upper key device for laterally lining up support structure and the vessel head and for maintaining this alignment when they are removed simultaneously from the core cylinder and vessel. When re-assembling the reactor, the top support structure and the vessel head are lowered simultaneously so that an opening in the top alignment structure engages in the upper extension of the bottom alignment structure. A plurality of alignment stuctures may be utilised round the circumference of the reactor vessel. The disposition of the invention also facilitates the removal of the core cylinder from the reactor vessel. In this way, the alignment on re-assembly is ensured by the re-entry of the bottom extension under the flange of the core cylinder with the groove or keyway of the reactor vessel [fr

  7. Quantification of Fatty Acid Oxidation Products Using On-line High Performance Liquid Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Levison, Bruce S.; Zhang, Renliang; Wang, Zeneng; Fu, Xiaoming; DiDonato, Joseph A.; Hazen, Stanley L.

    2013-01-01

    Oxidized fatty acids formed via lipid peroxidation are implicated in pathological processes such as inflammation and atherosclerosis. A number of methods may be used to detect specific oxidized fatty acids containing a single or multiple combinations of epoxide, hydroxyl, ketone and hydroperoxide moieties on varying carbon chain lengths from C8 up to C30. Some of these methods are nonspecific and their use in biological systems is fraught with difficulty. Measures of specific-oxidized fatty acid derivatives help in identifying oxidation pathways in pathological processes. We used liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-MS/MS) as efficient, selective and sensitive methods for identifying and analyzing multiple specific fatty acid peroxidation products in human plasma and other biological matrices. We then distilled the essential components of a number of these analyses to provide an efficient protocol by which fatty acid oxidation products and their parent compounds can be determined. In this protocol, addition of synthetic internal standard to the sample, followed by base hydrolysis at elevated temperature, and liquid-liquid phase sample extraction with lighter than water solvents facilitates isolation of the oxidized fatty acid species. These species can be identified and accurately quantified using stable isotope dilution and multiple reaction monitoring. Use of a coupled multiplexed gradient HPLC system on the front end enables high-throughput chromatography and more efficient use of mass spectrometer time. PMID:23499838

  8. Learning the ropes : winning in the international arena takes strong performances on a triple bottom line

    Energy Technology Data Exchange (ETDEWEB)

    Falkenberg, L.

    2000-10-02

    The challenges facing the petroleum industry in terms of their social and environmental responsibilities at an international level were discussed. Compared to a decade ago, today's company must satisfy shareholders of different types, including environmentalists, non-governmental organizations, religious groups, social activists, international charity agencies and the media. These groups have demanded a shift from financial accountability to a triple bottom line which includes the reporting of financial, social and environmental outcomes. In particular, this paper presented an example where Talisman Energy of Calgary started work in civil war raged Sudan and became the target of criticism from the American Secretary of State. Canada's Minister of Foreign Affairs was pressured by interest groups to impose sanctions on Talisman regardless of the constructive development in the local Sudanese community through projects supported by Talisman. Talisman is responding by communicating the real benefits of its involvement in Sudan, including vaccination campaigns, provision of clean water, funding for schools, jobs for local people, and support for human rights monitoring. 1 fig.

  9. Liquidity effects and FFA returns in the international shipping derivatives market

    OpenAIRE

    Alizadeh, Amir H.; Kappou, K; Tsouknidis, Dimitris; Visvikis, Ilias

    2015-01-01

    The study examines the impact of liquidity risk on freight derivatives returns. The Amihud liquidity ratio and bid–ask spreads are utilized to assess the existence of liquidity risk in the freight derivatives market. Other macroeconomic variables are used to control for market risk. Results indicate that liquidity risk is priced and both liquidity measures have a significant role in determining freight derivatives returns. Consistent with expectations, both liquidity measures are found to hav...

  10. Jacking mechanism for upper internals structure of a liquid metal nuclear reactor

    International Nuclear Information System (INIS)

    Gillett, J.E.; Wineman, A.L.

    1984-01-01

    A jacking mechanism is described for raising the upper internals structure of a liquid metal nuclear reactor which jacking mechanism uses a system of gears and drive shafts to transmit force from a single motor to four mechanically synchronized ball jacks to raise and lower support columns which support the upper internals structure. The support columns have a pin structure which rides up and down in a slot in a housing fixed to the reactor head. The pin has two locking plates which can be rotated around the pin to bring bolt holes through the locking plates into alignment with a set of bolt holes in the housing, there being a set of such housing bolt holes corresponding to both a raised and a lowered position of the support column. When the locking plate is so aligned, a surface of the locking plate mates with a surface in the housing such that the support column is then supported by the locking plate and not by the ball jacks. Since the locking plates are to be installed and bolted to the housing during periods of reactor operation, the ball jacks need not be sized to react the large forces which occur or potentially could occur on the upper internals structure of the reactor during operation. The locking plates react these loads. The ball jacks, used only during refueling, can be smaller, which enable conventionally available equipment to fulfill the precision requirements for the task within available space

  11. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas)

  12. On-line liquid-effluent monitoring of sewage at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Dreicer, M.; Cate, J.L.; Rueppel, D.W.; Huntzinger, C.J.; Gonzalez, M.A.

    1982-01-01

    An automatic on line sewage effluent monitoring system has been developed. A representative fraction of the total waste stream leaving the site is monitored for pH, radiation, and metals as it passes through a detection assembly. This assembly consists of an industrial pH probe, NaI radiation detectors, and an x-ray fluorescence metal detector. A microprocessor collects, reduces and analyzes the data to determine if the levels are acceptable by established environmental limits. Currently, if preset levels are exceeded, a sample of the suspect sewage is automatically collected for further analysis, and an alarm is sent to a station where personnel can be alerted to respond on a 24-hour basis. Since at least four hours pass before LLNL effluent reaches the treatment plant, sufficient time is available to alert emergency personnel, evaluate the situation, and if necessary arrange for diversion of the material to emergency holding basins at the treatment plant. Information on the current system is presented, and progress is reported in developing an on-line tritium monitor as an addition to the assembly

  13. Transport of liquid state nitrogen through long length service lines during thermal/vacuum testing. [in a Nimbus 6 satellite

    Science.gov (United States)

    Florio, F. A.

    1975-01-01

    Physical and analytical aspects associated with the transport are presented. Included is a definition of the problems and difficulties imposed by the servicing of a typical solid cryogen system, as well as a discussion of the transport requirements and of the rationale which governed their solution. A successful detailed transport configuration is defined, and the application of established mathematics to the design approach is demonstrated. The significance of head pressure, pressure drop, line friction, heat leak, Reynolds number, and the fundamental equilibrium demands of pressure and temperature were examined as they relate to the achievement of liquid state flow. Performance predictions were made for the transport system, and several analytical quantities are tabulated. These data are analyzed and compared with measured and calculated results obtained while actually servicing a solid cryogen system during thermal/vacuum testing.

  14. The accurate measurement of the disintegration rate of 55Fe using an internal liquid scintillation counter

    International Nuclear Information System (INIS)

    Botha, S.M.

    1979-01-01

    As the well-known 4πX-γ-coincidence method cannot be used directly to find the disintegration rate of 55 Fe, another method was developed in which a tracer nuclide, possessing coincident gamma radiation, was used. It was now possible to determine the disintegration rate indirectly by the coincidence method using an internal liquid scintillation counter. 54 Mn and 51 Cr which lie in the immediate vicinity of iron in the series of nuclides, are suitable tracers. They are also electron capture nuclides, but decaying to an excited state, were counted by the 4πX-γ-coincidence method. A mixed source, containing 55 Fe and the tracer, was also counted by the coincidence method so that the 4π-counting rate of 55 Fe was obtained as function of the tracer's counting efficiency. It was also essential to find a relationship between the counting efficiencies of the liquid scintillation counter for 55 Fe and the tracer. This relationship is called the effeciency function. Efficiency functions were calculated for 55 Fe and 54 Mn as well as for 55 Fe and 51 Cr. Finally the radioactive concentration of a solution of 55 Fe had been carefully determined by using 54 Mn and 51 Cr tracers. The results for the two different tracers agreed within the statistical uncertainty of 0,4%. The systematic uncertainty on the final results was estimated as 0,17%

  15. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    Science.gov (United States)

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  16. Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

    International Nuclear Information System (INIS)

    Bolotnikov, A.E.; Camarda, G.S.; Cui, Y.; Hossain, A.; Yang, G.; Yao, H.W.; James, R.B.

    2009-01-01

    The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, 1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field

  17. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    Energy Technology Data Exchange (ETDEWEB)

    Nischkauer, Winfried [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria); Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Vanhaecke, Frank [Department of Analytical Chemistry, Ghent University, Ghent (Belgium); Bernacchi, Sébastien; Herwig, Christoph [Institute of Chemical Engineering, Vienna University of Technology, Vienna (Austria); Limbeck, Andreas, E-mail: Andreas.Limbeck@tuwien.ac.at [Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna (Austria)

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL{sup −1} with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  18. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  19. Trace analysis of three antihistamines in human urine by on-line single drop liquid-liquid-liquid microextraction coupled to sweeping micellar electrokinetic chromatography and its application to pharmacokinetic study.

    Science.gov (United States)

    Gao, Wenhua; Chen, Yunsheng; Chen, Gaopan; Xi, Jing; Chen, Yaowen; Yang, Jianying; Xu, Ning

    2012-09-01

    A rapid and efficient dual preconcentration method of on-line single drop liquid-liquid-liquid microextraction (SD-LLLME) coupled to sweeping micellar electrokinetic chromatography (MEKC) was developed for trace analysis of three antihistamines (mizolastine, chlorpheniramine and pheniramine) in human urine. Three analytes were firstly extracted from donor phase (4 mL urine sample) adjusted to alkaline condition (0.5 M NaOH). The unionized analytes were subsequently extracted into a drop of n-octanol layered over the urine sample, and then into a microdrop of acceptor phase (100 mM H(3)PO(4)) suspended from a capillary inlet. The enriched acceptor phase was on-line injected into capillary with a height difference and then analyzed directly by sweeping MEKC. Good linear relationships were obtained for all analytes in a range of 6.25 × 10(-6) to 2.5 × 10(-4)g/L with correlation coefficients (r) higher than 0.987. The proposed method achieved limits of detections (LOD) varied from 1.2 × 10(-7) to 9.5 × 10(-7)g/L based on a signal-to-noise of 3 (S/N=3) with 751- to 1372-fold increases in detection sensitivity for analytes, and it was successfully applied to the pharmacokinetic study of three antihistamines in human urine after an oral administration. The results demonstrated that this method was a promising combination for the rapid trace analysis of antihistamines in human urine with the advantages of operation simplicity, high enrichment factor and little solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. A liquid lens switching-based motionless variable fiber-optic delay line

    Science.gov (United States)

    Khwaja, Tariq Shamim; Reza, Syed Azer; Sheikh, Mumtaz

    2018-05-01

    We present a Variable Fiber-Optic Delay Line (VFODL) module capable of imparting long variable delays by switching an input optical/RF signal between Single Mode Fiber (SMF) patch cords of different lengths through a pair of Electronically Controlled Tunable Lenses (ECTLs) resulting in a polarization-independent operation. Depending on intended application, the lengths of the SMFs can be chosen accordingly to achieve the desired VFODL operation dynamic range. If so desired, the state of the input signal polarization can be preserved with the use of commercially available polarization-independent ECTLs along with polarization-maintaining SMFs (PM-SMFs), resulting in an output polarization that is identical to the input. An ECTL-based design also improves power consumption and repeatability. The delay switching mechanism is electronically-controlled, involves no bulk moving parts, and can be fully-automated. The VFODL module is compact due to the use of small optical components and SMFs that can be packaged compactly.

  1. High performance liquid chromatographic analysis of insulin degradation products from a cultured kidney cell line

    International Nuclear Information System (INIS)

    Duckworth, W.C.; Hamel, F.G.; Liepnieks, J.; Frank, B.H.; Yagil, C.; Rabkin, R.

    1988-01-01

    The kidney is a major site for insulin removal and degradation, but the subcellular processes and enzymes involved have not been established. We have examined this process by analyzing insulin degradation products by HPLC. Monoiodoinsulin specifically labeled on either the A14 or B26 tyrosine residue was incubated with a cultured kidney epithelial cell line, and both intracellular and extracellular products were examined on HPLC. The products were then compared with products of known structure generated by hepatocytes and the enzyme insulin protease. Intracellular and extracellular products were different, suggesting two different degradative pathways, as previously shown in liver. The extracellular degradation products eluted from HPLC both before and after sulfitolysis similarly with hepatocyte products and products generated by insulin protease. The intracellular products also eluted identically with hepatocyte products. Based on comparisons with identified products, the kidney cell generates two fragments from the A chain of intact insulin, one with a cleavage at A13-A14 and the other at A14-A15. The B chain of intact insulin is cleaved in a number of different sites, resulting in peptides that elute identically with B chain peptides cleaved at B9-B10, B13-B14, B16-B17, B24-B25, and B25-B26. These similarities with hepatocytes and insulin protease suggest that liver and kidney have similar mechanisms for insulin degradation and that insulin protease or a very similar enzyme is involved in both tissues

  2. The direct determination of double bond positions in lipid mixtures by liquid chromatography/in-line ozonolysis/mass spectrometry

    International Nuclear Information System (INIS)

    Sun, Chenxing; Zhao, Yuan-Yuan; Curtis, Jonathan M.

    2013-01-01

    Highlights: ► An ozonolysis reactor was coupled in-line with mass spectrometry (O 3 -MS). ► Double bond positions in FAME were determined unambiguously without standards. ► LC directly connected to O 3 -MS allowed double bond localization in lipid mixtures. ► LC/O 3 -MS applied to bovine fat demonstrated practical use in lipid analysis. -- Abstract: The direct determination of double bond positions in unsaturated lipids using in-line ozonolysis-mass spectrometry (O 3 -MS) is described. In this experiment, ozone penetrates through the semi-permeable Teflon AF-2400 tubing containing a flow of a solution of fatty acid methyl esters (FAME). Unsaturated FAME are thus oxidized by the ozone and cleaved at the double bond positions. The ozonolysis products then flow directly into the atmospheric pressure photoionization (APPI) source of a mass spectrometer for analysis. Aldehyde products retaining the methyl ester group are indicative of the double bond positions in unsaturated FAME. For the first time, O 3 -MS is able to couple directly to high performance liquid chromatography (HPLC), making the double bond localization in lipid mixtures possible. The application of LC/O 3 -MS has been demonstrated for a fat sample from bovine adipose tissue. A total of 9 unsaturated FAME including 6 positional isomers were identified unambiguously, without comparison to standards. The in-line ozonolysis reaction apparatus is applicable to most mass spectrometers without instrumental modification; it is also directly compatible with various LC columns. The LC/O 3 -MS method described here is thus a practical, versatile and easy to use new approach to the direct determination of double bond positions in lipids, even in complex mixtures

  3. The direct determination of double bond positions in lipid mixtures by liquid chromatography/in-line ozonolysis/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Chenxing; Zhao, Yuan-Yuan [Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta T6G 2P5 (Canada); Curtis, Jonathan M., E-mail: jcurtis1@ualberta.ca [Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta T6G 2P5 (Canada)

    2013-01-31

    Highlights: ► An ozonolysis reactor was coupled in-line with mass spectrometry (O{sub 3}-MS). ► Double bond positions in FAME were determined unambiguously without standards. ► LC directly connected to O{sub 3}-MS allowed double bond localization in lipid mixtures. ► LC/O{sub 3}-MS applied to bovine fat demonstrated practical use in lipid analysis. -- Abstract: The direct determination of double bond positions in unsaturated lipids using in-line ozonolysis-mass spectrometry (O{sub 3}-MS) is described. In this experiment, ozone penetrates through the semi-permeable Teflon AF-2400 tubing containing a flow of a solution of fatty acid methyl esters (FAME). Unsaturated FAME are thus oxidized by the ozone and cleaved at the double bond positions. The ozonolysis products then flow directly into the atmospheric pressure photoionization (APPI) source of a mass spectrometer for analysis. Aldehyde products retaining the methyl ester group are indicative of the double bond positions in unsaturated FAME. For the first time, O{sub 3}-MS is able to couple directly to high performance liquid chromatography (HPLC), making the double bond localization in lipid mixtures possible. The application of LC/O{sub 3}-MS has been demonstrated for a fat sample from bovine adipose tissue. A total of 9 unsaturated FAME including 6 positional isomers were identified unambiguously, without comparison to standards. The in-line ozonolysis reaction apparatus is applicable to most mass spectrometers without instrumental modification; it is also directly compatible with various LC columns. The LC/O{sub 3}-MS method described here is thus a practical, versatile and easy to use new approach to the direct determination of double bond positions in lipids, even in complex mixtures.

  4. Development of an Evaluation Methodology for Triple Bottom Line Reports Using International Standards on Reporting

    Science.gov (United States)

    Skouloudis, Antonis; Evangelinos, Konstantinos; Kourmousis, Fotis

    2009-08-01

    The purpose of this article is twofold. First, evaluation scoring systems for triple bottom line (TBL) reports to date are examined and potential methodological weaknesses and problems are highlighted. In this context, a new assessment methodology is presented based explicitly on the most widely acknowledged standard on non-financial reporting worldwide, the Global Reporting Initiative (GRI) guidelines. The set of GRI topics and performance indicators was converted into scoring criteria while the generic scoring devise was set from 0 to 4 points. Secondly, the proposed benchmark tool was applied to the TBL reports published by Greek companies. Results reveal major gaps in reporting practices, stressing the need for the further development of internal systems and processes in order to collect essential non-financial performance data. A critical overview of the structure and rationale of the evaluation tool in conjunction with the Greek case study is discussed while recommendations for future research on the field of this relatively new form of reporting are suggested.

  5. Development of an evaluation methodology for triple bottom line reports using international standards on reporting.

    Science.gov (United States)

    Skouloudis, Antonis; Evangelinos, Konstantinos; Kourmousis, Fotis

    2009-08-01

    The purpose of this article is twofold. First, evaluation scoring systems for triple bottom line (TBL) reports to date are examined and potential methodological weaknesses and problems are highlighted. In this context, a new assessment methodology is presented based explicitly on the most widely acknowledged standard on non-financial reporting worldwide, the Global Reporting Initiative (GRI) guidelines. The set of GRI topics and performance indicators was converted into scoring criteria while the generic scoring devise was set from 0 to 4 points. Secondly, the proposed benchmark tool was applied to the TBL reports published by Greek companies. Results reveal major gaps in reporting practices, stressing the need for the further development of internal systems and processes in order to collect essential non-financial performance data. A critical overview of the structure and rationale of the evaluation tool in conjunction with the Greek case study is discussed while recommendations for future research on the field of this relatively new form of reporting are suggested.

  6. Optical trapping of colloidal particles and measurement of the defect line tension and colloidal forces in a thermotropic nematic liquid crystal

    International Nuclear Information System (INIS)

    Smalyukh, I.I.; Kuzmin, A.N.; Kachynski, A.V.; Prasad, P.N.; Lavrentovich, O.D.

    2005-01-01

    We demonstrate optical trapping and manipulation of transparent microparticles suspended in a thermotropic nematic liquid crystal with low birefringence. We employ the particle manipulation to measure line tension of a topologically stable disclination line and to determine colloidal interaction of particles with perpendicular surface anchoring of the director. The three-dimensional director fields and positions of the particles manipulated by laser tweezers are visualized by fluorescence confocal polarizing microscopy

  7. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  8. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  9. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory

  10. High internal phase emulsion (HIPE)-templated biopolymeric oleofilms containing an ultra-high concentration of edible liquid oil.

    Science.gov (United States)

    Wijaya, Wahyu; Van der Meeren, Paul; Dewettinck, Koen; Patel, Ashok R

    2018-04-25

    We report, for the first time, the fabrication of oleofilms (containing more than 97 wt% edible liquid oil) using high internal phase emulsions (with oil volume fraction φoil = 0.82) as templates. Advanced microscopy studies revealed an interesting microstructure of these films where jammed oil droplets were embedded in a dried matrix of biopolymeric complexes.

  11. Simultaneous determination of metolazone and valsartan in plasma by on-line SPE coupled with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Jiezhao; Chen, Meiling; Li, Ying; Yu, Fanglin; Cheng, Xiaohui; Yang, Yang; Liu, Yan; Xie, Xiangyang; Li, Zhiping; Zhang, Hui; Mei, Xingguo

    2017-10-01

    Combination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1-100 ng/mL and 1-1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of the metolazone and valsartan combination tablets in beagle dogs.

  12. Walking the Line: Canadian Federalism, the Council of Ministers of Education, and the Case of International Education, 1970-1984

    Science.gov (United States)

    Allison, John

    2007-01-01

    This article will examine Canadian politicians' and administrators' leadership in the realm of education-related international activities. In the era between the 1960s and the 1980s, it became increasingly difficult for educational leaders to walk the line dividing federal and provincial responsibility in this field. Educational authorities at the…

  13. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  14. Determination of denaturated proteins and biotoxins by on-line size-exclusion chromatography-digestion-liquid chromatography-electrospray mass spectrometry

    NARCIS (Netherlands)

    Carol, J.; Gorseling, M.C.J.K.; Jong, C.F. de; Lingeman, H.; Kientz, C.E.; Baar, B.L.M. van; Irth, H.

    2005-01-01

    A multidimensional analytical method for the rapid determination and identification of proteins has been developed. The method is based on the size-exclusion fractionation of protein-containing samples, subsequent on-line trypsin digestion and desalination, and reversed-phase high-performance liquid

  15. Selective on-line detection of boronic acids and derivatives in high-performance liquid chromatography eluates by post-column reaction with alizarin

    NARCIS (Netherlands)

    Duval, F.L.; Wardani, P.A.; Zuilhof, H.; Beek, van T.A.

    2015-01-01

    An on-line high-performance liquid chromatography (HPLC) method for the rapid and selective detection of boronic acids in complex mixtures was developed. After optimization experiments at an HPLC flow rate of 0.40 mL/min, the HPLC-separated analytes were mixed post-column with a solution of 75 µM

  16. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  17. In-line coupling of supported liquid membrane extraction to capillary electrophoresis for simultaneous analysis of basic and acidic drugs in urine

    Czech Academy of Sciences Publication Activity Database

    Pantůčková, Pavla; Kubáň, Pavel

    2017-01-01

    Roč. 1519, OCT (2017), s. 137-144 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA16-09135S Institutional support: RVO:68081715 Keywords : supported liquid membrane extraction * capillary electrophoresis * in-line sample treatment Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 3.981, year: 2016

  18. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

    Science.gov (United States)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL - 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with

  19. On-line liquid chromatography/tandem mass spectrometry simultaneous determination of opiates, cocainics and amphetamines in dried blood spots.

    Science.gov (United States)

    Saussereau, E; Lacroix, C; Gaulier, J M; Goulle, J P

    2012-02-15

    A novel approach has been developed for the illicit drugs quantitative determination using dried blood spots (DBS) on filter paper. The illicit drugs tested were opiates (morphine and its 3- and 6-glucuronide metabolites, codeine, 6-monoacetylmorphine), cocainics (ecgonine methylester, benzoylecgonine, cocaine, cocaethylene) and amphetamines (amphetamine, methamphetamine, MDA, MDMA, MDEA). The described method, requiring a small blood volume, is based on high performance liquid chromatography coupled to tandem mass spectrometry using on-line extraction. A Whatman card 903 was spotted with 30μL of whole blood and left overnight to dry at room temperature. A 3-mm diameter disk was removed using a manual punch, suspended in 150μL of water for 10min with ultrasonication, and then 100μL was injected in the on-line LC-MS/MS system. An Oasis HLB was used as an extraction column and a C18 Atlantis as an analytical column. The chromatographic cycle was performed with 20mM ammonium formate buffer (pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 16min. Detection was performed in positive electrospray ionization mode (ESI+) with a Quattro Micro (Waters). Recoveries of all analytes were up to 80%. DBS were stored in duplicate at 4°C and -20°C for up to 6 months. Illicit drugs seemed to be much more stabled at -20°C. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating authentic samples; significant correlations were obtained. This DBS assay has potential as rapid, sensitive and inexpensive option for the illicit drugs determination in small blood volumes, which seems of great interest in suspected cases of driving under the influence of drugs. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. 6th International Conference on Physics of Liquid Matter : Modern Problems

    CERN Document Server

    Lebovka, Nikolai

    2015-01-01

    These proceedings comprise invited and contributed papers presented at PLMMP-2014, addressing modern problems in the fields of liquids, solutions and confined systems, critical phenomena, as well as colloidal and biological systems. The book focuses on state-of-the-art developments in contemporary physics of liquid matter. The papers presented here are organized into four parts: (i) structure of liquids in confined systems, (ii) phase transitions, supercritical liquids and glasses, (iii) colloids, and (iv) medical and biological aspects and cover the most recent developments in the broader field of liquid state including interdisciplinary problems.

  1. Emergence of liquid crystalline order in the lowest Landau level of a quantum Hall system with internal anisotropy

    Science.gov (United States)

    Ciftja, Orion

    2018-05-01

    It has now become evident that interplay between internal anisotropy parameters (such as electron mass anisotropy and/or anisotropic coupling of electrons to the substrate) and electron-electron correlation effects can create a rich variety of possibilities especially in quantum Hall systems. The electron mass anisotropy or material substrate effects (for example, the piezoelectric effect in GaAs) can lead to an effective anisotropic interaction potential between electrons. For lack of knowledge of realistic ab-initio potentials that may describe such effects, we adopt a phenomenological approach and assume that an anisotropic Coulomb interaction potential mimics the internal anisotropy of the system. In this work we investigate the emergence of liquid crystalline order at filling factor ν = 1/6 of the lowest Landau level, a state very close to the point where a transition from the liquid to the Wigner solid happens. We consider small finite systems of electrons interacting with an anisotropic Coulomb interaction potential and study the energy stability of an anisotropic liquid crystalline state relative to its isotropic Fermi-liquid counterpart. Quantum Monte Carlo simulation results in disk geometry show stabilization of liquid crystalline order driven by an anisotropic Coulomb interaction potential at all values of the interaction anisotropy parameter studied.

  2. Reduced cost design of liquid lithium target for international fusion material irradiation facility (IFMIF)

    International Nuclear Information System (INIS)

    Nakamura, Hiroo; Ida, Mizuho; Sugimoto, Masayoshi; Takeuchi, Hiroshi; Yutani, Toshiaki

    2001-01-01

    The International Fusion Materials Irradiation Facility (IFMIF) is being jointly planned to provide an accelerator-based D-Li neutron source to produce intense high energy neutrons (2 MW/m 2 ) up to 200 dpa and a sufficient irradiation volume (500 cm 3 ) for testing the candidate materials and components up to about a full lifetime of their anticipated use in ITER and DEMO. To realize such a condition, 40 MeV deuteron beam with a current of 250 mA is injected into high speed liquid lithium flow with a speed of 20 m/s. Following Conceptual Design Activity (1995-1998), a design study with focus on cost reduction without changing its original mission has been done in 1999. The following major changes to the CAD target design have been considered in the study and included in the new design: i) number of the Li target has been changed from 2 to 1, ii) spare of impurity traps of the Li loop was removed although the spare will be stored in a laboratory for quick exchange, iii) building volume was reduced via design changes in lithium loop length. This paper describes the reduced cost design of the lithium target system and recent status of Key Element Technology activities. (author)

  3. The zenithal 4-m International Liquid Mirror Telescope: a unique facility for supernova studies

    Science.gov (United States)

    Kumar, Brajesh; Pandey, Kanhaiya L.; Pandey, S. B.; Hickson, P.; Borra, E. F.; Anupama, G. C.; Surdej, J.

    2018-05-01

    The 4-m International Liquid Mirror Telescope (ILMT) will soon become operational at the newly developed Devasthal observatory near Nainital (Uttarakhand, India). Coupled with a 4k × 4k pixels CCD detector and TDI optical corrector, it will reach approximately 22.8, 22.3, and 21.4 mag in the g΄, r΄, and i΄ spectral bands, respectively, in a single scan. The limiting magnitudes can be further improved by co-adding the consecutive night images in particular filters. The uniqueness to observe the same sky region by looking towards the zenith direction every night makes the ILMT a unique instrument to detect new supernovae (SNe) by applying the image subtraction technique. High cadence (˜24 h) observations will help to construct dense sampling multi-band SNe light curves. We discuss the importance of the ILMT facility in the context of SNe studies. Considering the various plausible cosmological parameters and observational constraints, we perform detailed calculations of the expected SNe rate that can be detected with the ILMT in different spectral bands.

  4. Monitoring gradient profile on-line in micro- and nano-high performance liquid chromatography using conductivity detection.

    Science.gov (United States)

    Zhang, Min; Chen, Apeng; Lu, Joann J; Cao, Chengxi; Liu, Shaorong

    2016-08-19

    In micro- or nano-flow high performance liquid chromatography (HPLC), flow-splitters and gradient elutions are commonly used for reverse phase HPLC separations. When a flow splitter was used at a high split-ratio (e.g., 1000:1 or higher), the actual gradient may deviate away from the programmed gradient. Sometimes, mobile phase concentrations can deviate by as much as 5%. In this work, we noticed that the conductivity (σ) of a gradient decreased with the increasing organic-solvent fraction (φ). Based on the relationship between σ and φ, a method was developed for monitoring gradient profile on-line to record any deviations in these HPLC systems. The conductivity could be measured by a traditional conductivity detector or a capacitively coupled contactless conductivity detector (C(4)D). The method was applied for assessing the performance of an electroosmotic pump (EOP) based nano-HPLC. We also observed that σ value of the gradient changed with system pressure; a=0.0175ΔP (R(2)=0.964), where a is the percentage of the conductivity increase and ΔP is the system pressure in bar. This effect was also investigated. Copyright © 2016. Published by Elsevier B.V.

  5. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  6. Atomistic modelling of evaporation and explosive boiling of thin film liquid argon over internally recessed nanostructured surface

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, Mohammad Nasim, E-mail: nasim@me.buet.ac.bd.com; Shavik, Sheikh Mohammad, E-mail: shavik@me.buet.ac.bd.com; Rabbi, Kazi Fazle, E-mail: rabbi35.me10@gmail.com; Haque, Mominul, E-mail: mominulmarup@gmail.com [Department of Mechanical Engineering, Bangladesh University of Engineering & Technology (BUET) Dhaka-1000 (Bangladesh)

    2016-07-12

    Molecular dynamics (MD) simulations have been carried out to investigate evaporation and explosive boiling phenomena of thin film liquid argon on nanostructured solid surface with emphasis on the effect of solid-liquid interfacial wettability. The nanostructured surface considered herein consists of trapezoidal internal recesses of the solid platinum wall. The wetting conditions of the solid surface were assumed such that it covers both the hydrophilic and hydrophobic conditions and hence effect of interfacial wettability on resulting evaporation and boiling phenomena was the main focus of this study. The initial configuration of the simulation domain comprised of a three phase system (solid platinum, liquid argon and vapor argon) on which equilibrium molecular dynamics (EMD) was performed to reach equilibrium state at 90 K. After equilibrium of the three-phase system was established, the wall was set to different temperatures (130 K and 250 K for the case of evaporation and explosive boiling respectively) to perform non-equilibrium molecular dynamics (NEMD). The variation of temperature and density as well as the variation of system pressure with respect to time were closely monitored for each case. The heat flux normal to the solid surface was also calculated to illustrate the effectiveness of heat transfer for hydrophilic and hydrophobic surfaces in cases of both nanostructured surface and flat surface. The results obtained show that both the wetting condition of the surface and the presence of internal recesses have significant effect on normal evaporation and explosive boiling of the thin liquid film. The heat transfer from solid to liquid in cases of surface with recesses are higher compared to flat surface without recesses. Also the surface with higher wettability (hydrophilic) provides more favorable conditions for boiling than the low-wetting surface (hydrophobic) and therefore, liquid argon responds quickly and shifts from liquid to vapor phase faster in

  7. 49 CFR 192.476 - Internal corrosion control: Design and construction of transmission line.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Design and... STANDARDS Requirements for Corrosion Control § 192.476 Internal corrosion control: Design and construction... the risk of internal corrosion. At a minimum, unless it is impracticable or unnecessary to do so, each...

  8. 75 FR 62560 - Exemption and Equivalent Arrangements Under the International Convention on Load Lines, 1966, as...

    Science.gov (United States)

    2010-10-12

    ... familiar load line feature is the well-known ``Plimsoll mark'' visible on each side of the hull. However... load lines allow unrestricted operations on any ocean, at any time of year (an extreme example being....'' When an exemption is granted, a certificate of exemption may be issued. Exemptions: Both ICLL Article 6...

  9. Development of on-line heavy water analysis by vibrating probe density meter and multiple internal reflectance infrared spectrometry

    International Nuclear Information System (INIS)

    Jones, V.D.; Nora, B.

    1984-01-01

    Achieving high productivity in the Savannah River Plant nuclear reactors requires that the heavy water (D 2 O) moderator be maintained at a high purity level. Since the D 2 O purity will degrade with time, a fraction of the moderator must be continually reprocessed to remove H 2 O. This rework process uses a series of fractional distillation columns. The process control is based on laboratory analyses of process samples every four hours. The sample streams, which can range from 0.10 to 99.80 mol % D 2 O, are analyzed using infrared spectrophotometry. An automatic on-line analysis would provide tighter process control and reduce personnel exposure to the tritiated moderator. Two instruments are being evaluated for on-line control; an Anton/Parr DPR 2000 density measuring system and a General Analysis Corporation LAN-I infrared liquid stream monitor

  10. Performance of a coumarin-based liquid dosimeter for phantom evaluations of internal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi-Ae [Department of Radiology, Brigham and Women' s Hospital, Boston, MA 02115 (United States): Harvard Medical School, Boston, MA 02115 (United States)]. E-mail: miaepark@bwh.Harvard.edu; Moore, Stephen C. [Department of Radiology, Brigham and Women' s Hospital, Boston, MA 02115 (United States): Harvard Medical School, Boston, MA 02115 (United States); Limpa-Amara, Naengnoi [Department of Radiology, Brigham and Women' s Hospital, Boston, MA 02115 (United States): Harvard Medical School, Boston, MA 02115 (United States); Kang Zhuang [Department of Physics, University of Massachusettes at Lowell, Lowell, MA 01854 (United States); Makrigiorgos, G. Mike [Dana Faber-Brigham and Women' s Cancer Center, Boston, MA 01225 (United States): Harvard Medical School, Boston, MA 02115 (United States)

    2006-12-20

    Targeted radionuclide therapy (TRT) requires accurate absorbed dose estimation in individual patients. It has been shown that a coumarin-based liquid dosimeter is useful for various phantom geometries of relevance to patient-specific internal dosimetry. The purpose of this study was to refine the performance limits of the coumarin-3-carboxylic acid (CCA) dosimeter using the high-energy {beta}-emitter, Y-90, by measuring the dosimeter's dependence on dose rate, by finding the maximum dose limit, and by comparing measured dose values to those from Monte Carlo (MC) simulation. Non-fluorescent CCA is converted to highly fluorescent 7-hydroxyl-coumarin-3-carboxylic acid (7-OH-CCA) upon irradiation. We measured the Y-90-induced fluorescence from 7-OH-CCA under different conditions. Fluorescence was measured using activity concentrations from 1.1 to 181 MBq/cc, providing initial dose rates from 0.7 to 117 cGy/min. To determine the maximum dose limit, fluorescence was measured for different elapsed times from 4 to 150 h, using a fixed activity concentration, 3.7 MBq/cc. A Cs-137 irradiator was used for calibration, to convert fluorescence measurements to absorbed dose. We calculated absorbed dose using the DOSXYZnrc MC program. We modeled the geometry of cuvettes realistically, including plastic walls, surrounding air, and Y-90 in liquid. S-values of Y-90 in water were calculated using 1-mm cubic voxels. A linear dependence of fluorescence on dose rate was observed up to 80 cGy/min, and the dependence on total dose was linear up to {approx}20 Gy The average difference between calculated and measured dose values over 9 samples was 3.6{+-}2%. For our geometry, the dose based on voxel S-values was within 1% of that calculated using MC simulation of the phantom. We refined the performance limits of a CCA-based dosimeter for phantom studies of TRT using Y-90, and confirmed a close agreement between measured and calculated dose values. CCA dosimetry is a promising technique

  11. Welcome to the 21st International Conference on Spectral Line Shapes

    Science.gov (United States)

    2012-12-01

    Dear Participants and Guests On behalf of the Rector's Office, welcome to St. Petersburg University, one of the oldest, largest and most prestigious universities in Russia. The 12 Colleges Building (named after the Collegia of Peter the Great's time, Ministries in the modern sense of the word) has been home to the University since 1804. St. Petersburg State University is the successor of the first Russian University founded by Peter the Great on 24 January 1724. It's distinguished faculty members include mathematicians Chebyshev and Smirnov, physicists Lenz and Fock, chemists Mendeleev and Butlerov, embryologist Kovalevsky, and physiologist Sechenov. Several of our alumni won Nobel Prizes - Pavlov, Semenov, Kantorovich, Landau and Prokhorov. The University is the alma mater of two presidents of Russia, Vladimir Putin and Dmitry Medvedev. St. Petersburg State University today consists of 19 faculties on two campuses: in the historic downtown, on Vasilyevsky Island, and in Peterhof. The Faculty of Physics carries out research projects through the efforts of 260 employees, of which 150 hold doctoral degrees, and 50 have been awarded Grand Doctorates. The work is done in a vast variety of areas, from the physics of elementary particles to the physics of the atmosphere. Optics and spectroscopy has been a particularly significant area of research. This field of inquiry goes back to the work of Academician D S Rozhdestvensky more than 70 years ago, when he first suggested his famous hook method. After him the work was headed by S Frisch, corresponding member of the Academy of Sciences and editor-in-chief of Optics and Spectroscopy Journal. Today research projects in optics involve over 50 staff members, graduate and post-graduate students. Work involves projects on spectroscopy of cold and hot plasma, atomic and molecular spectroscopy, non-linear spectroscopy and spectroscopic analysis. Our scholars support active international ties with their colleagues worldwide. The

  12. Revisiting Vertical Models To Simulate the Line Shape of Electronic Spectra Adopting Cartesian and Internal Coordinates.

    Science.gov (United States)

    Cerezo, Javier; Santoro, Fabrizio

    2016-10-11

    Vertical models for the simulation of spectroscopic line shapes expand the potential energy surface (PES) of the final state around the equilibrium geometry of the initial state. These models provide, in principle, a better approximation of the region of the band maximum. At variance, adiabatic models expand each PES around its own minimum. In the harmonic approximation, when the minimum energy structures of the two electronic states are connected by large structural displacements, adiabatic models can breakdown and are outperformed by vertical models. However, the practical application of vertical models faces the issues related to the necessity to perform a frequency analysis at a nonstationary point. In this contribution we revisit vertical models in harmonic approximation adopting both Cartesian (x) and valence internal curvilinear coordinates (s). We show that when x coordinates are used, the vibrational analysis at nonstationary points leads to a deficient description of low-frequency modes, for which spurious imaginary frequencies may even appear. This issue is solved when s coordinates are adopted. It is however necessary to account for the second derivative of s with respect to x, which here we compute analytically. We compare the performance of the vertical model in the s-frame with respect to adiabatic models and previously proposed vertical models in x- or Q 1 -frame, where Q 1 are the normal coordinates of the initial state computed as combination of Cartesian coordinates. We show that for rigid molecules the vertical approach in the s-frame provides a description of the final state very close to the adiabatic picture. For sizable displacements it is a solid alternative to adiabatic models, and it is not affected by the issues of vertical models in x- and Q 1 -frames, which mainly arise when temperature effects are included. In principle the G matrix depends on s, and this creates nonorthogonality problems of the Duschinsky matrix connecting the normal

  13. Competition, liquidity and stability: international evidence at the bank and systemic levels

    OpenAIRE

    Nguyen, Thi Ngoc My

    2017-01-01

    This thesis investigates the impact of market power on bank liquidity; the association between competition and systemic liquidity; and whether the associations between liquidity and stability at both bank- and systemic- levels are affected by competition. The first research question is explored in the context of 101 countries over 1996-2013 while the second and the third, which require listed banks, use a smaller sample of 32 nations during 2001-2013. The Panel Least Squares and the system Ge...

  14. Intrinsic line shape of electromagnetic radiation from a stack of intrinsic Josephson junctions synchronized by an internal cavity resonance

    Science.gov (United States)

    Koshelev, Alexei

    2013-03-01

    Stacks of intrinsic Josephson-junctions are realized in mesas fabricated out of layered superconducting single crystals, such as Bi2Sr2CaCu2O8 (BSCCO). Synchronization of phase oscillations in different junctions can be facilitated by the coupling to the internal cavity mode leading to powerful and coherent electromagnetic radiation in the terahertz frequency range. An important characteristic of this radiation is the shape of the emission line. A finite line width appears due to different noise sources leading to phase diffusion. We investigated the intrinsic line shape caused by the thermal noise for a mesa fabricated on the top of a BSCCO single crystal. In the ideal case of fully synchronized stack the finite line width is coming from two main contributions, the quasiparticle-current noise inside the mesa and the fluctuating radiation in the base crystal. We compute both contributions and conclude that for realistic mesa's parameters the second mechanism typically dominates. The role of the cavity quality factor in the emission line spectrum is clarified. Analytical results were verified by numerical simulations. In real mesa structures part of the stack may not be synchronized and chaotic dynamics of unsynchronized junctions may determine the real line width. Work supported by UChicago Argonne, LLC, under contract No. DE-AC02-06CH11357.

  15. Three lines of defence model and the role of internal audit activities as the response to the global economic crisis

    Science.gov (United States)

    Dragičević Radičević, T.; Stojanović Trivanović, M.; Stanojević, Lj

    2017-05-01

    The existing framework of corporate governance has shown a number of weaknesses, and the result was a new economic crisis at the global level. The main problems were identified as: increased risk of investors, non-transparency of information, conflict of interest between corporation subjects. European Institute of Internal Auditors in response to the strengthening the trust in information, shareholders activism, better communication, which all will lead to the reduction of risks and restore investors confidence, proposed the Model Three Lines of Defence, where the key role has internal audit.

  16. Evidence for a liquid-liquid critical point in supercooled water within the E3B3 model and a possible interpretation of the kink in the homogeneous nucleation line

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Yicun; Skinner, J. L. [Theoretical Chemistry Institute and Department of Chemistry, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2016-06-07

    Supercooled water exhibits many thermodynamic anomalies, and several scenarios have been proposed to interpret them, among which the liquid-liquid critical point (LLCP) hypothesis is the most commonly discussed. We investigated Widom lines and the LLCP of deeply supercooled water, by using molecular dynamics simulation with a newly reparameterized water model that explicitly includes three-body interactions. Seven isobars are studied from ambient pressure to 2.5 kbar, and Widom lines are identified by calculating maxima in the coefficient of thermal expansion and the isothermal compressibility (both with respect to temperature). From these data we estimate that the LLCP of the new water model is at 180 K and 2.1 kbar. The oxygen radial distribution function is calculated along the 2 kbar isobar. It shows a steep change in the height of its second peak between 180 and 185 K, which indicates a transition between the high-density liquid and low-density liquid phases and which is consistent with the ascribed location of the critical point. The good agreement of the height of the second peak of the radial distribution function between simulation and experiment at 1 bar, as a function of temperature, supports the validity of the model. The location of the LLCP within the model is close to the kink in the experimental homogeneous nucleation line. We use existing experimental data to argue that the experimental LLCP is at 168 K and 1.95 kbar and speculate how this LLCP and its Widom line might be responsible for the kink in the homogeneous nucleation line.

  17. Publishing SNP genotypes of human embryonic stem cell lines: policy statement of the International Stem Cell Forum Ethics Working Party.

    Science.gov (United States)

    Knoppers, Bartha M; Isasi, Rosario; Benvenisty, Nissim; Kim, Ock-Joo; Lomax, Geoffrey; Morris, Clive; Murray, Thomas H; Lee, Eng Hin; Perry, Margery; Richardson, Genevra; Sipp, Douglas; Tanner, Klaus; Wahlström, Jan; de Wert, Guido; Zeng, Fanyi

    2011-09-01

    Novel methods and associated tools permitting individual identification in publicly accessible SNP databases have become a debatable issue. There is growing concern that current technical and ethical safeguards to protect the identities of donors could be insufficient. In the context of human embryonic stem cell research, there are no studies focusing on the probability that an hESC line donor could be identified by analyzing published SNP profiles and associated genotypic and phenotypic information. We present the International Stem Cell Forum (ISCF) Ethics Working Party's Policy Statement on "Publishing SNP Genotypes of Human Embryonic Stem Cell Lines (hESC)". The Statement prospectively addresses issues surrounding the publication of genotypic data and associated annotations of hESC lines in open access databases. It proposes a balanced approach between the goals of open science and data sharing with the respect for fundamental bioethical principles (autonomy, privacy, beneficence, justice and research merit and integrity).

  18. Measuring the internal energy content of molecules transported across the liquid-gas interface

    Energy Technology Data Exchange (ETDEWEB)

    Maselli, Olivia J; Gascooke, Jason R; Buntine, Mark A [School of Chemistry and Physics, University of Adelaide, SA 5005 (Australia); Lawrance, Warren D, E-mail: m.buntine@curtin.edu.a [School of Chemistry, Physics and Earth Sciences, Flinders University, GPO Box 2100, Adelaide SA 5000 (Australia)

    2009-09-01

    Many details concerning the mechanism associated with the liberation of molecules from a liquid surface remain to be elucidated. We use the liquid microjet technique coupled with laser spectroscopy to measure the rotational and vibrational energy content of benzene spontaneously evaporating from a water-ethanol solution. These measurements provide molecular level insight into the mass and energy transfer processes associated with evaporation.

  19. Measuring the internal energy content of molecules transported across the liquid-gas interface

    International Nuclear Information System (INIS)

    Maselli, Olivia J; Gascooke, Jason R; Buntine, Mark A; Lawrance, Warren D

    2009-01-01

    Many details concerning the mechanism associated with the liberation of molecules from a liquid surface remain to be elucidated. We use the liquid microjet technique coupled with laser spectroscopy to measure the rotational and vibrational energy content of benzene spontaneously evaporating from a water-ethanol solution. These measurements provide molecular level insight into the mass and energy transfer processes associated with evaporation.

  20. Long term storage in liquid nitrogen leads to only minor phenotypic and gene expression changes in the mammary carcinoma model cell line BT474.

    Science.gov (United States)

    Fazekas, Judit; Grunt, Thomas W; Jensen-Jarolim, Erika; Singer, Josef

    2017-05-23

    Cancer cell lines are indispensible surrogate models in cancer research, as they can be used off-the-shelf, expanded to the desired extent, easily modified and exchanged between research groups for affirmation, reproduction or follow-up experiments.As malignant cells are prone to genomic instability, phenotypical changes may occur after certain passages in culture. Thus, cell lines have to be regularly authenticated to ensure data quality. In between experiments these cell lines are often stored in liquid nitrogen for extended time periods.Although freezing of cells is a necessary evil, little research is performed on how long-term storage affects cancer cell lines. Therefore, this study investigated the effects of a 28-year long liquid nitrogen storage period on BT474 cells with regard to phenotypical changes, differences in cell-surface receptor expression as well as cytokine and gene expressional variations. Two batches of BT474 cells, one frozen in 1986, the other directly purchased from ATCC were investigated by light microscopy, cell growth analysis, flow cytometry and cytokine as well as whole-transcriptome expression profiling. The cell lines were morphologically indifferent and showed similar growth rates and similar cell-surface receptor expression. Transcriptome analysis revealed significant differences in only 26 of 40,716 investigated RefSeq transcripts with 4 of them being up-regulated and 22 down-regulated. This study demonstrates that even after very long periods of storage in liquid nitrogen, cancer cell lines display only minimal changes in their gene expression profiles. However, also such minor changes should be carefully assessed before continuation of experiments, especially if phenotypic alterations can be additionally observed.

  1. High-performance liquid chromatography on-line coupled to high-field NMR and mass spectrometry for structure elucidation of constituents of Hypericum perforatum L

    DEFF Research Database (Denmark)

    Hansen, S. H.; Jensen, A. G.; Cornett, Claus

    1999-01-01

    The on-line separation and structure elucidation of naphthodianthrones, flavonoids, and other constituents of an extract from Hypericum perforatum L, using high performance liquid chromatography (HPLC) coupled on-line with ultraviolet-visible, nuclear magnetic resonance (NMR), and mass spectrometry...... (MS) is described. A conventional reversed-phase HPLC system using ammonium acetate as the buffer substance in the eluent tvas used, and proton NMR spectra were obtained on a 500 MHz NMR instrument. The MS and MS/MS analyses were performed using negative electrospray ionization, In the present study...

  2. Measurements of the osmotic pressure in liquid mixtures of 3He and 4He near the lambda line and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.

    1977-01-01

    Values of the concentration susceptibility (par. deltax/par. deltaΔ)/sub T,P/ near the lambda line and tricritical point in liquid mixtures of 3He and 4 He were calculated from measurements of osmotic pressure differences. Measurements were made by inducing a small 3 He mole fraction difference Δx between two chambrs separated by a pressure transducer, and measuring the resulting osmotic pressure difference as a function of temperature

  3. Comparative analysis of the internalization of the macrophage receptor sialoadhesin in human and mouse primary macrophages and cell lines.

    Science.gov (United States)

    De Schryver, Marjorie; Leemans, Annelies; Pintelon, Isabel; Cappoen, Davie; Maes, Louis; Caljon, Guy; Cos, Paul; Delputte, Peter L

    2017-06-01

    Sialoadhesin (Sn) is a surface receptor expressed on resident macrophages with the ability to bind with sialic acids. During inflammation, an upregulation of Sn is observed. Upon binding of monoclonal antibodies to Sn, the receptor becomes internalized and this has been observed in multiple species. The latter characteristic, combined with the strong upregulation of Sn on inflammatory macrophages and the fact that Sn-positive macrophages contribute to certain inflammatory diseases, makes Sn an interesting entry portal for phenotype-modulating or cytotoxic drugs. Such drugs or toxins can be linked to Sn-specific antibodies which should enable their targeted uptake by macrophages. However, the activity of such drugs depends not only on their internalization but also on the intracellular trafficking and final fate in the endolysosomal system. Although information is available for porcine Sn, the detailed mechanisms of human and mouse Sn internalization and subsequent intracellular trafficking are currently unknown. To allow development of Sn-targeted therapies, differences across species and cellular background need to be characterized in more detail. In the current report, we show that internalization of human and mouse Sn is dynamin-dependent and clathrin-mediated, both in primary macrophages and CHO cell lines expressing a recombinant Sn. In primary macrophages, internalized Sn-specific F(ab') 2 fragments are located mostly in the early endosomes. With Fc containing Sn-specific antibodies, there is a slight shift towards lysosomal localization in mouse macrophages, possibly because of an interaction with Fc receptors. Surprisingly, in CHO cell lines expressing Sn, there is a predominant lysosomal localization. Our results show that the mechanism of Sn internalization and intracellular trafficking is concurrent in the tested species. The cellular background in which Sn is expressed and the type of antibody used can affect the intracellular fate, which in turn can

  4. Analysis of heterocyclic amines in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography−tandem mass spectrometry

    International Nuclear Information System (INIS)

    Kataoka, Hiroyuki; Inoue, Tsutomu; Saito, Keita; Kato, Hisato; Masuda, Kazufumi

    2013-01-01

    Graphical abstract: Mutagenic and carcinogenic heterocyclic amines are accumulated in the hair of smoker. -- Highlights: •On-line in-tube solid-phase microextraction of heterocyclic amines was optimized. •Fourteen heterocyclic amines were simultaneously determined by LC–MS/MS. •Pico gram levels of heterocyclic amines could be easily analyzed within 15 min. •Heterocyclic amines could be quantitatively analyzed from several milligrams of hair. •The method is useful for the assessment of long-term exposure to heterocyclic amines. -- Abstract: Mutagenic and carcinogenic heterocyclic amines (HCAs) are formed during heating of various proteinaceous foods, but human exposure to HCAs has not yet been elucidated in detail. To assess long-term exposure to HCAs, we developed a simple and sensitive method for measuring HCAs in hair by automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). Using a Zorbax Eclipse XDB-C8 column, 16 HCAs were analyzed within 15 min. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL sample at a flow rate of 200 μL min −1 using a Supel-Q PLOT capillary column as an extraction device. The extracted HCAs were easily desorbed from the column by passage of the mobile phase, with no carryover observed. This in-tube SPME LC–MS/MS method showed good linearity for HCAs in the range of 10–2000 pg mL −1 , with correlation coefficients above 0.9989 (n = 18), using stable isotope-labeled HCA internal standards. The detection limits (S/N = 3) of 14 HCAs except for MeAαC and Glu-P-1 were 0.10–0.79 pg mL −1 . This method was successfully utilized to analyze 14 HCAs in hair samples without any interference peaks, with quantitative limits (S/N = 10) of about 0.17–1.32 pg mg −1 hair. Using this method, we evaluated the exposure to HCAs in cigarette smoke and the suitability of using hair HCAs as exposure biomarkers

  5. On-line hyphenation of centrifugal partition chromatography and high pressure liquid chromatography for the fractionation of flavonoids from Hippophaë rhamnoides L. berries.

    Science.gov (United States)

    Michel, Thomas; Destandau, Emilie; Elfakir, Claire

    2011-09-09

    Centrifugal Partition Chromatography (CPC), a liquid-liquid preparative chromatography using two immiscible solvent systems, benefits from numerous advantages for the separation or purification of synthetic or natural products. This study presents the on-line hyphenation of CPC-Evaporative Light Scattering Detector (CPC-ELSD) with High Performance Liquid Chromatography-UV (HPLC-UV) for the fractionation of flavonols from a solvent-free microwave extract of sea buckthorn (Hippophaë rhamnoides L., Elaeagnaceae) berries. An Arizona G system was used for the fractionation of flavonoids by CPC and a fused core Halo C18 column allowed the on-line analyses of collected fractions by HPLC. The on-line CPC/HPLC procedure allowed the simultaneous fractionation step at preparative scale combined with the HPLC analyses which provide direct fingerprint of collected fractions. Thus the crude extract was simplified and immediate information on the composition of fractions could be obtained. Furthermore, this methodology reduced the time of post-fractionation steps and facilitated identification of main molecules by Mass Spectrometry (MS). Rutin, isorhamnetin-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin-3-O-glucoside, isorhamnetin-rhamnoside, quercetin and isorhamnetin were identified. CPC-ELSD/HPLC-UV could be considered as a high-throughput technique for the guided fractionation of bioactive natural products from complex crude extracts. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. The line copy task for kinesthesia and internal movement representation: application in children.

    NARCIS (Netherlands)

    Smits-Engelsman, B.C.M.; Duysens, J.E.J.

    2008-01-01

    In the present study a new test is proposed and tested, which requires ability to use information both from kinesthesia and from mental rotation of previously produced cyclic movements over a distinct trajectory. This Line Copy Test (LICT) was performed by 58 children aged 7-11 years. For the

  7. Preparation and Characterization of Silicone Liquid Core/Polymer Shell Microcapsules via Internal Phase Separation

    DEFF Research Database (Denmark)

    Gonzalez, Lidia; Kostrzewska, Malgorzata; Ma, Baoguang

    2014-01-01

    Microcapsules with a silicone liquid core surrounded by a polymeric shell were synthesisedthrough the controlled phase separation. The dispersed silicone phase consisted of the shellpolymer PMMA, a good solvent for the PMMA (dichloromethane, DCM) and a poor solvent(methylhydrosiloxane dimethylsil......Microcapsules with a silicone liquid core surrounded by a polymeric shell were synthesisedthrough the controlled phase separation. The dispersed silicone phase consisted of the shellpolymer PMMA, a good solvent for the PMMA (dichloromethane, DCM) and a poor solvent...

  8. Third-line Targeted Therapy in Metastatic Renal Cell Carcinoma: Results from the International Metastatic Renal Cell Carcinoma Database Consortium.

    Science.gov (United States)

    Wells, J Connor; Stukalin, Igor; Norton, Craig; Srinivas, Sandy; Lee, Jae Lyun; Donskov, Frede; Bjarnason, Georg A; Yamamoto, Haru; Beuselinck, Benoit; Rini, Brian I; Knox, Jennifer J; Agarwal, Neeraj; Ernst, D Scott; Pal, Sumanta K; Wood, Lori A; Bamias, Aristotelis; Alva, Ajjai S; Kanesvaran, Ravindran; Choueiri, Toni K; Heng, Daniel Y C

    2017-02-01

    The use of third-line targeted therapy (TTT) in metastatic renal cell carcinoma (mRCC) is not well characterized and varies due to the lack of robust data to guide treatment decisions. This study examined the use of third-line therapy in a large international population. To evaluate the use and efficacy of targeted therapy in a third-line setting. Twenty-five international cancer centers provided consecutive data on 4824 mRCC patients who were treated with an approved targeted therapy. One thousand and twelve patients (21%) received TTT and were included in the analysis. Patients were analyzed for overall survival (OS) and progression-free survival using Kaplan-Meier curves, and were evaluated for overall response. Cox regression analyses were used to determine the statistical association between OS and the six factors included in the International Metastatic Renal Cell Carcinoma Database Consortium (IMDC) prognostic model. Subgroup analysis was performed on patients stratified by their IMDC prognostic risk status. Everolimus was the most prevalent third-line therapy (27.5%), but sunitinib, sorafenib, pazopanib, temsirolimus, and axitinib were all utilized in over ≥9% of patients. Patients receiving any TTT had an OS of 12.4 mo, a progression-free survival of 3.9 mo, and 61.1% of patients experienced an overall response of stable disease or better. Patients not receiving TTT had an OS of 2.1 mo. Patients with favorable- (7.2%) or intermediate-risk (65.3%) disease had the highest OS with TTT, 29.9 mo and 15.5 mo, respectively, while poor-risk (27.5%) patients survived 5.5 mo. Results are limited by the retrospective nature of the study. TTT remains highly heterogeneous. The IMDC prognostic criteria can be used to stratify third-line patients. TTT use in favorable- and intermediate-risk patients was associated with the greatest OS. Patients with favorable- and intermediate-prognostic criteria disease treated with third-line targeted therapy have an associated

  9. Tantala-based sol-gel coating for capillary microextraction on-line coupled to high-performance liquid chromatography.

    Science.gov (United States)

    Tran, MinhPhuong; Turner, Erica B; Segro, Scott S; Fang, Li; Seyyal, Emre; Malik, Abdul

    2017-11-03

    A sol-gel organic-inorganic hybrid sorbent, consisting of chemically integrated tantalum (V) ethoxide (TaEO) and polypropylene glycol methacrylate (PPGM), was developed for capillary microextraction (CME). The sol-gel sorbent was synthesized within a fused silica capillary through hydrolytic polycondensation of TaEO and chemical incorporation of PPGM into the evolving sol-gel tantala network. A part of the organic-inorganic hybrid sol-gel network evolving in the vicinity of the capillary walls had favorable conditions to get chemically bonded to the silanol groups on the capillary surface forming a surface-bonded coating. The newly developed sol-gel sorbent was employed to isolate and enrich a variety of analytes from aqueous samples for on-line analysis by high-performance liquid chromatography (HPLC) equipped with a UV detector. CME was performed on aqueous samples containing trace concentrations of analytes representing polycyclic aromatic hydrocarbons, ketones, alcohols, amines, nucleosides, and nucleotides. This sol-gel hybrid coating provided efficient extraction with CME-HPLC detection limits ranging from 4.41pM to 28.19 pM. Due to direct chemical bonding between the sol-gel sorbent coating and the fused silica capillary inner surface, this sol-gel sorbent exhibited enhanced solvent stability. The sol-gel tantala-based sorbent also exhibited excellent pH stability over a wide pH range (pH 0-pH 14). Furthermore, it displayed great performance reproducibility in CME-HPLC providing run-to-run HPLC peak area relative standard deviation (RSD) values between 0.23% and 3.83%. The capillary-to-capillary RSD (n=3), characterizing capillary preparation method reproducibility, ranged from 0.24% to 4.11%. The results show great performance consistency and application potential for the sol-gel tantala-PPGM sorbent in various fields including biomedical, pharmaceutical, and environmental areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    Science.gov (United States)

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  11. Design and implementation of an automated liquid-phase microextraction-chip system coupled on-line with high performance liquid chromatography

    DEFF Research Database (Denmark)

    Li, Bin; Petersen, Nickolaj J.; Payán, María D Ramos

    2014-01-01

    . The composition of the supported liquid membrane (SLM) and carrier was optimized in order to achieve reasonable extraction performance of all the five alkaloids. With 1-octanol as SLM solvent and with 25mM sodium octanoate as anionic carrier, extraction recoveries for the different opium alkaloids ranged between...

  12. The Line between Peaceful Settlement of Disputes and the Use of Force in International Law

    Directory of Open Access Journals (Sweden)

    Oana Cristina Necula

    2012-12-01

    Full Text Available In this article, we attempt to analyze the evolution of a conflictual situation between atleast two international parties, examining each stage involved, with focus on peaceful solutions.However, what we observe is that no all disputes can be resolved through the use of common peacefulmeans. Refusing to accept violet methods of international conflict resolution and expressing faith inhuman values, freedom and fundamental rights of people, we believe that, in cases like these,imposing peaceful coercive measures in order to restore cooperation between states, becomesnecessary. These actions specifically, represent the subject of this paper. First and foremost, we mustunderstand that the international system is not a stand-alone one, butone that has evolved over theyears from tribes, empires and colonies, being at this moment composed of sovereign nation states,most of them allies as part of inter-governmental organizations. We are currently witnessing thecreating of a new subject of international law-the European Union-which does not aim to become anational state, an inter-state organization, or a federation of states. It selectively combines the featuresof these, creating a whole new international entity, whose evolution is still unknown, but that willundoubtedly change the system certainly in a gradual manner.In the midst of all thesetransformations of the international world lie the differences between mentalities and humanbehavior, or maybe even the similarities between them. These get translated into conflicts and theirresolution is intended to be as least invasive as possible, eventually leading to the development oflegal instruments designed to protect the freedom and sovereignty of the parties involved.

  13. On-line internal corrosion monitoring and data management for remote pipelines: a technology update

    Energy Technology Data Exchange (ETDEWEB)

    Wold, Kjell; Stoen, Roar; Jenssen, Hallgeir [Roxar Flow Measurement AS, Stavanger (Norway); Carvalho, Anna Maria [Roxar do Brasil Ltda., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Internal corrosion monitoring of remote pipelines can be costly and demanding on resources. Online and non-intrusive monitoring directly on the pipe wall can improve the quality of measurements, make installation more convenient and allow more efficient communication of data. The purpose of this paper is to describe a non-intrusive technology, and show examples on field installations of the system. Furthermore, the non-intrusive technology data can be stored, interpreted and combined with conventional (intrusive) system information, in order to get a full picture of internal corrosion profile, corrosion rate and trends regarding the pipeline being monitored. (author)

  14. An on-line communication system as an international catalysator for initiating storage projects

    International Nuclear Information System (INIS)

    Hennig, E.; Stephanblome, Th.

    1998-01-01

    The presented internet platform realizes an international contact stock of the companies and institutes being interested in storage technologies and cooperation and will take over the function of a catalysator for the planning of future storage use. In this regard the system creates an information and marketing device that will help, in the shape of an international, virtual exhibition hall, to find new markets, that are interesting for producers and suppliers of electrical energy storage technologies. In this virtual exhibition hall, need and offer regarding the electrical energy storage technologies are shown in order to support the main aim of the works regarding Annex IX, the starting of concrete projects. (author)

  15. Short-coherence in-line phase-shifting infrared digital holographic microscopy for measurement of internal structure in silicon

    Science.gov (United States)

    Xi, Teli; Dou, Jiazhen; Di, Jianglei; Li, Ying; Zhang, Jiwei; Ma, Chaojie; Zhao, Jianlin

    2017-06-01

    Short-coherence in-line phase-shifting digital holographic microscopy based on Michelson interferometer is proposed to measure internal structure in silicon. In the configuration, a short-coherence infrared laser is used as the light source in order to avoid the interference formed by the reference wave and the reflected wave from the front surface of specimen. At the same time, in-line phase-shifting configuration is introduced to overcome the problem of poor resolution and large pixel size of the infrared camera and improve the space bandwidth product of the system. A specimen with staircase structure is measured by using the proposed configuration and the 3D shape distribution are given to verify the effectiveness and accuracy of the method.

  16. The international hardwood lumber market and potential impacts on your bottom line

    Science.gov (United States)

    Bill Luppold; Matthew. Bumgardner

    2014-01-01

    Even if you don't sell logs or lumber to foreign customers, the international hardwood market can impact your business in significant ways, and smart business leaders are taking notice so that they are ready for shifting market impacts. Many people believe that lumber exporting is only an opportunity for larger sawmills. However, even if you have a portable mill...

  17. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos

    2013-06-30

    A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  18. Crack and damage assessment in concrete and polymer matrices using liquids released internally from hollow optical fibers

    Science.gov (United States)

    Dry, Carolyn M.; McMillan, William

    1996-05-01

    This was an investigation into the feasibility of using liquid core optical fibers for the detection and self repair of cracking in cement or polymer materials generated by dynamic or static loading. These experiments relied on our current research sponsored by the National Science Foundation. That work on the concept of internal adhesive delivery from hollow fibers for repair was here combined with the nondestructive fiber optic analysis of crack location and volume. The combination of the ability to remotely measure crack occurrence in real time and determine the location and volume of crack damage in the matrix is unique in the field of optic sensors. The combination of this with crack repair, rebonding of any detached or broken fibers, and replenishment of liquid core chemicals, when necessary, make this a potentially powerful sensing and repair tool. Work on this research topic was sponsored by the University of Illinois.

  19. Postendocytic sorting of constitutively internalized dopamine transporter in cell lines and dopaminergic neurons

    DEFF Research Database (Denmark)

    Eriksen, Jacob; Bjørn-Yoshimoto, Walden Emil; Jørgensen, Trine Nygaard

    2010-01-01

    The dopamine transporter (DAT) mediates reuptake of released dopamine and is the target for psychostimulants, such as cocaine and amphetamine. DAT undergoes marked constitutive endocytosis, but little is known about the fate and sorting of the endocytosed transporter. To study DAT sorting in cells...... lines, we fused the one-transmembrane segment protein Tac to DAT, thereby generating a transporter (TacDAT) with an extracellular antibody epitope suited for trafficking studies. TacDAT was functional and endocytosed constitutively in HEK293 cells. According to an ELISA-based assay, TacDAT intracellular...

  20. Methodological aspects on international biofuels trade: International streams and trade of solid and liquid biofuels in Finland

    International Nuclear Information System (INIS)

    Heinimoe, J.

    2008-01-01

    The use of biomass for fuel is increasing in industrialised countries. Rapidly developing biomass markets for energy purposes along with weak information on biofuels trade that statistics offer have been incentives for several recently published studies investigating the status of biofuels trade. The comparison of the studies is often challenging due particularly to the various approaches to the indirect trade of biofuels and the diverse data sources utilised. The purpose of this study was to provide an overview of the Finnish situation with respect to the status of the streams of international biofuels trade. Parallel to this, the study aimed to identify methodological and statistical challenges in observing international biofuels trade. The study analysed available statistical information and introduced a procedure to obtain a clear overview on import and export streams of biofuels. In Finland, the total direct import and export of biofuels, being mainly composed of wood pellets and tall oil, is tiny in comparison with the total consumption of biofuels. Instead, the indirect trade has remarkable importance. Large import volumes of industrial raw wood make Finland a net importer of biofuels. In 2004, approximately 22% (64 PJ) of wood-based energy in Finland originated from imported wood. The study showed that the indirect trade of biofuels may be a significant sector of global biofuels trade. In the case of Finland, a comprehensive compilation of statistics on energy and forestry enabled the determination of the trade status satisfactory. However, national and international statistics should be further developed to take better into consideration international trade and to support continuously developing biofuels markets. (author)

  1. Investigation of internalization and cytotoxicity of 125I-[Tyr3]-octreotide in NCI-H446 cell line

    International Nuclear Information System (INIS)

    Sun Junjie; Fan Wo; Xu Yujie; Zhang Youjiu; Zhu Ran; Hu Mingjiang

    2004-01-01

    Objective: To investigate the [Tyr 3 ]-octreotide (TOC) internalizing capacity of NCI-H446 cell line, and the cytotoxicity of 125 I-TOC in NCI-H446 cell line. To assess the therapeutic radiopharmaceutical potentiality of 125 I-TOC for the somatostatin receptor (SSTR) positive tumor. Methods: NCI-H446 cells were incubated together with 125 I-TOC for different periods of time, the amount of internalized 125 I-TOC and the 125 I-TOC bound on the cellular nucleus were detected with γ counter, respectively. The viability of the cells was analyzed by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay at different time points with various doses of 125 I-TOC, free 125 I and TOC. Results: 125 I-TOC was internalized into the nucleus and bound on the nucleus in a time-dependent manner. 125 I-TOC bound on the nucleus increased to the highest level at 24 h, the amount of nucleus bound 125 I-TOC at 24 h was 7 times higher than that at 0.5 h. Cytotoxicity of 125 I-TOC in SSTR positive NCI-H446 cells was also dose- and time-dependent. The supreme effect of cytotoxicity was found at 96 h with 74 kBq 125 I-TOC, the survival ratio of cells was reduced to (44.8 ± 7.2)%. Conclusions: 125 I-TOC can be internalized into SSTR positive cells mediated by SSTR. The NCI-H446 cells can be killed by Auger electron emitting from 125 I-TOC. Effect of cytotoxicity showed dose- and time-dependent

  2. Characterization of human embryonic stem cell lines by the International Stem Cell Initiative

    Czech Academy of Sciences Publication Activity Database

    Adewumi, O.; Aflatoonian, B.; Ahrlund-Richter, L.; Amit, M.; Andrews, P.W.; Beighton, G.; Bello, P.A.; Benvenisty, N.; Berry, L.S.; Bevan, S.; Blum, B.; Brooking, J.; Chen, K.G.; Choo, A.B.H.; Churchill, G.A.; Corbel, M.; Damjanov, I.; Draper, J.S.; Dvořák, Petr; Emanuelsson, K.; Fleck, R.A.; Ford, A.; Gertow, K.; Gertsenstein, M.; Gokhale, P.J.; Hamilton, R.S.; Hampl, Aleš; Healy, L.E.; Hovatta, O.; Hyllner, J.; Imreh, M.P.; Itskovitz-Eldor, J.; Jackson, J.; Johnson, J.L.; Jones, M.; Kee, K.; King, B.L.; Knowles, B.B.; Lako, M.; Lebrin, F.; Mallon, B.S.; Manning, D.; Mayshar, Y.; Mckay, D.G.; Michalska, A.E.; Mikkola, M.; Mileikovsky, M.; Minger, S.L.; Moore, H.D.; Mummery, Ch.L.; Nagy, A.; Nakutsuji, N.; O´Brien, C.M.; Oh, S.K.W.; Olsson, C.; Otonkoski, T.; Park, K.Y.; Passier, R.; Patel, H.; Patel, M.; Pedersen, R.; Pera, M.F.; Piekarczyk, M.S.; Pera, R.A.P.; Reubinoff, B.E.; Robins, A.J.; Rossant, J.; Rugg-Gunn, P.; Schulz, T.C.; Semb, H.; Sherrer, E.S.; Siemen, H.; Stacey, G.N.; Stojkovic, M.; Suemori, H.; Szatkiewicz, J.; Turetsky, T.; Tuuri, T.; Van den Brink, S.; Vintersten, K.; Vuoristo, S.; Ward, D.; Weaver, T.A.; Young, L.A.; Zhang, W.

    2007-01-01

    Roč. 25, č. 7 (2007), s. 803-816 ISSN 1087-0156 R&D Projects: GA MŠk 1M0538; GA ČR GA301/05/0463; GA ČR GA305/05/0434 Institutional research plan: CEZ:AV0Z50390512 Keywords : International Stem Cell Initiative Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 22.848, year: 2007

  3. Concrete lining of the core-foundation interface to prevent internal erosion: An efficiency assessment

    OpenAIRE

    Granados García, Alfredo; Garrote de Marcos, Luis; Granados García, Isabel; Remesal, José Antonio

    2015-01-01

    The core-foundation interface of the embankment dams requires particular attention during design and construction, and specific surveillance during operation. A deficient treatment of this area may facilitate seepage along the interface and erosion of the core-base which, in turn, could lead to a major internal erosion process. Several dam incidents and failures were initiated following this mechanism. For instance, an imperfect core-foundation treatment was one of the causes of the Teton Dam...

  4. Cell Penetrating Capacity and Internalization Mechanisms Used by the Synthetic Peptide CIGB-552 and Its Relationship with Tumor Cell Line Sensitivity.

    Science.gov (United States)

    Astrada, Soledad; Fernández Massó, Julio Raúl; Vallespí, Maribel G; Bollati-Fogolín, Mariela

    2018-03-30

    CIGB-552 is a twenty-amino-acid novel synthetic peptide that has proven to be effective in reducing tumor size and increasing lifespan in tumor-bearing mice. Such capability is conferred by its cell-penetrating peptide character, which allows it to enter cells and elicit a pro-apoptotic effect through its major mediator, COMMD1 protein. Cell-penetrating peptides are able to use different internalization mechanisms, such as endocytosis or direct transduction through the plasma membrane. Although CIGB-552 cytotoxicity has been evaluated in several non-tumor- and tumor-derived cell lines, no data regarding the relationship between cell line sensitivity, cell penetrating capacity, the internalization mechanisms involved, COMMD1 expression levels, or its subcellular localization has yet been produced. Here, we present the results obtained from a comparative analysis of CIGB-552 sensitivity, internalization capacity and the mechanisms involved in three human tumor-derived cell lines from different origins: mammary gland, colon and lung (MCF-7, HT-29 and H460, respectively). Furthermore, cell surface markers relevant for internalization processes such as phosphatidylserine, as well as CIGB-552 target COMMD1 expression/localization, were also evaluated. We found that both endocytosis and transduction are involved in CIGB-552 internalization in the three cell lines evaluated. However, CIGB-552 incorporation efficiency and contribution of each mechanism is cell-line dependent. Finally, sensitivity was directly correlated with high internalization capacity in those cell lines where endocytosis had a major contribution on CIGB-552 internalization.

  5. Biofabrication of morphology improved cadmium sulfide nanoparticles using Shewanella oneidensis bacterial cells and ionic liquid: For toxicity against brain cancer cell lines.

    Science.gov (United States)

    Wang, Li; Chen, Siyuan; Ding, Yiming; Zhu, Qiang; Zhang, Nijia; Yu, Shuqing

    2018-01-01

    The present work determines the anticancer activity of bio-mediated synthesized cadmium sulfide nanoparticles using the ionic liquid and bacterial cells (Shewanella oneidensis). Bacterial cells have been exposed to be important resources that hold huge potential as ecofriendly, cost-effective, evading toxic of dangerous chemicals and the alternative of conventional physiochemical synthesis. The Shewanella oneidensis is an important kind of metal reducing bacterium, known as its special anaerobic respiratory and sulfate reducing capacity. The crystalline nature, phase purity and surface morphology of biosynthesized cadmium sulfide nanoparticles were analyzed by Fourier transform infrared spectroscopy, X-ray diffraction, Field emission scanning electron microscopy, Energy dispersive spectroscopy and Transmission electron microscopy. The use of imidazolium based ionic liquids as soft templating agent for controlling self-assembly and crystal growth direction of metal sulfide nanoparticles has also advanced as an important method. The microscopic techniques showed that the nanoparticles are designed on the nano form and have an excellent spherical morphology, due to the self-assembled mechanism of ionic liquid assistance. The antitumor efficiency of the cadmium sulfide nanoparticles was investigated against brain cancer cell lines using rat glioma cell lines. The effectively improved nano-crystalline and morphological structure of CdS nanoparticles in the presence of IL exhibit excellent cytotoxicity and dispersion ability on the cell shape is completely spread out showing a nice toxic environment against cancer cells. The cytotoxicity effect of cadmium sulfide nanoparticles was discussed with a diagrammatic representation. Copyright © 2017. Published by Elsevier B.V.

  6. Internal Dosimetry Of I-131 For Radiation Workers Based On Analysis Of The Human Urine And Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai; Le Van Ngoc

    2011-01-01

    Internal dosimetry of I-131 for radiation workers based on analysis of the human urine, measuring radioactivity by the liquid scintillation system, and dose calculation by the specialized code has been firstly studied at the Nuclear Research Institute. Urine samples from the subjects internally contaminated with I-131 through respiratory ways were collected, chemically processed, measured beta radioactivities of I-131 by the liquid scintillation system of ALOKA-LSC-6100, and then thyroid doses and effective ones for whole-body were calculated by using the specialized code of LUDEP 2.0. Based on chemically separation procedure for I-131 in urine samples and the low background HPGe gamma spectrometer of Canberra for measuring radioactivity, efficiency for chemical separation was determined to be (86.1 ± 5.0)%. The experimental results for 9 subjects with urine samples to be collected during 4 operating courses of Dalat nuclear reactor with production of I-131 (from June to September, 2010) were shown that thyroid doses and effective ones for whole-body for each course of I-131 production were in ranges of from 0.11 to 13.00 mSv and from 0.01 to 0.71 mSv, respectively. Therefore, totally average doses per year for thyroid and whole-body were less than the correlative levels of permissible doses. Besides, the liquid scintillation method was also compared experimentally with the gamma spectrometry (measuring directly urine samples by the gamma spectrometer to be carried out at the Institute before) was shown that errors on dosimetric results between them were less than 12%. This was proved the dosimetry has had a confidence, and it could be applied for internal dosimetry for radiation workers contacting with unsealed sources of I-131 in radiation installations as well as for diagnostic and therapeutic patients in health ones. (author)

  7. International school on high field NMR spectroscopy for solids and liquids

    International Nuclear Information System (INIS)

    Marion, D.; Meier, B.; Keeler, J.; Berthault, P.; Vedrine, P.; Grandinetti, P.; Delsuc, M.A.; Spiess, H.

    2006-01-01

    The aim of the school is to offer high-level pedagogical courses on a wide range of liquid- and solid-state NMR concepts and techniques: theory, instrumentation (magnets and probes), data acquisition, processing and analysis, measurement of dipolar and quadrupolar couplings, spin relaxation and hyper-polarization. This document gathers only the slides of most presentations

  8. International school on high field NMR spectroscopy for solids and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Marion, D.; Meier, B.; Keeler, J.; Berthault, P.; Vedrine, P.; Grandinetti, P.; Delsuc, M.A.; Spiess, H

    2006-07-01

    The aim of the school is to offer high-level pedagogical courses on a wide range of liquid- and solid-state NMR concepts and techniques: theory, instrumentation (magnets and probes), data acquisition, processing and analysis, measurement of dipolar and quadrupolar couplings, spin relaxation and hyper-polarization. This document gathers only the slides of most presentations.

  9. CFD Simulation and Experimental Measurement of Gas Holdup and Liquid Interstitial Velocity in Internal Loop Airlift Reactor

    Czech Academy of Sciences Publication Activity Database

    Šimčík, Miroslav; Mota, A.; Růžička, Marek; Vicente, A.; Teixeira, J.

    2011-01-01

    Roč. 66, č. 14 (2011), s. 3268-3279 ISSN 0009-2509. [International Conference on Gas–Liquid and Gas–Liquid–Solid Reactor Engineering /10./. Braga, 26.06.2011-29.06.2011] R&D Projects: GA ČR GA104/07/1110 Grant - others:FCT(PT) SFRH/BD/37082/2007 Institutional research plan: CEZ:AV0Z40720504 Keywords : cfd * airlift * hydrodynamics Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.431, year: 2011

  10. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer.

    Science.gov (United States)

    Biedermann, Maurus; Grob, Koni

    2013-03-15

    Insertion of a programmed temperature vaporizing (PTV) injector under conditions of concurrent solvent recondensation (CSR) into the on-line HPLC-GC interface for on-column transfer (such as the retention gap technique with partially concurrent eluent evaporation) enables filtering off high boiling or involatile sample constituents by a desorption temperature adjusted to the required cut-off. Details of this technique were investigated and optimized. Memory effects, observed when transferred liquid was sucked backwards between the transfer line and the wall of the injector liner, can be kept low by a small purge flow rate through the transfer line at the end of the transfer and the release of the liquid through a narrow bore capillary kept away from the liner wall. The column entrance should be within the well heated zone of the injector to prevent losses of solute material retained on the liner wall during the splitless period. The desorption temperature must be maintained until an elevated oven temperature is reached to prevent peak broadening resulting of a cool inlet section in the bottom part of the injector. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. On-line liquid chromatography-gas chromatography: A novel approach for the analysis of phytosterol oxidation products in enriched foods.

    Science.gov (United States)

    Scholz, Birgit; Wocheslander, Stefan; Lander, Vera; Engel, Karl-Heinz

    2015-05-29

    A novel methodology for the automated qualitative and quantitative determination of phytosterol oxidation products in enriched foods via on-line liquid chromatography-gas chromatography (LC-GC) was established. The approach is based on the LC pre-separation of acetylated phytosterols and their corresponding oxides using silica as stationary phase and a mixture of n-hexane/methyl tert-butyl ether/isopropanol as eluent. Two LC-fractions containing (i) 5,6-epoxy- and 7-hydroxyphytosterols, and (ii) 7-ketophytosterols are transferred on-line to the GC for the analysis of their individual compositions on a medium polar trifluoropropylmethyl polysiloxane capillary column. Thus, conventionally employed laborious off-line purification and enrichment steps can be avoided. Validation data, including recovery, repeatability, and reproducibility of the method, were elaborated using an enriched margarine as example. The margarine was subjected to a heating procedure in order to exemplarily monitor the formation of phytosterol oxidation products. Quantification was performed using on-line LC-GC-FID, identification of the analytes was based on on-line LC-GC-MS. The developed approach offers a new possibility for the reliable and fast analysis of phytosterol oxidation products in enriched foods. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  13. Stability of arsenic peptides in plant extracts: off-line versus on-line parallel elemental and molecular mass spectrometric detection for liquid chromatographic separation.

    Science.gov (United States)

    Bluemlein, Katharina; Raab, Andrea; Feldmann, Jörg

    2009-01-01

    The instability of metal and metalloid complexes during analytical processes has always been an issue of an uncertainty regarding their speciation in plant extracts. Two different speciation protocols were compared regarding the analysis of arsenic phytochelatin (As(III)PC) complexes in fresh plant material. As the final step for separation/detection both methods used RP-HPLC simultaneously coupled to ICP-MS and ES-MS. However, one method was the often used off-line approach using two-dimensional separation, i.e. a pre-cleaning step using size-exclusion chromatography with subsequent fraction collection and freeze-drying prior to the analysis using RP-HPLC-ICP-MS and/or ES-MS. This approach revealed that less than 2% of the total arsenic was bound to peptides such as phytochelatins in the root extract of an arsenate exposed Thunbergia alata, whereas the direct on-line method showed that 83% of arsenic was bound to peptides, mainly as As(III)PC(3) and (GS)As(III)PC(2). Key analytical factors were identified which destabilise the As(III)PCs. The low pH of the mobile phase (0.1% formic acid) using RP-HPLC-ICP-MS/ES-MS stabilises the arsenic peptide complexes in the plant extract as well as the free peptide concentration, as shown by the kinetic disintegration study of the model compound As(III)(GS)(3) at pH 2.2 and 3.8. But only short half-lives of only a few hours were determined for the arsenic glutathione complex. Although As(III)PC(3) showed a ten times higher half-life (23 h) in a plant extract, the pre-cleaning step with subsequent fractionation in a mobile phase of pH 5.6 contributes to the destabilisation of the arsenic peptides in the off-line method. Furthermore, it was found that during a freeze-drying process more than 90% of an As(III)PC(3) complex and smaller free peptides such as PC(2) and PC(3) can be lost. Although the two-dimensional off-line method has been used successfully for other metal complexes, it is concluded here that the fractionation and

  14. Lines of experimental research in developing mathematical models for estimating internal radiation

    International Nuclear Information System (INIS)

    Bad'in, V.I.; Ermilov, A.P.; Margulis, U.Ya.; Khrushch, V.T.

    The report presents material involved with the statistical approach to the problem of modeling internal radiation and the trend of experimental research dictated by that approach. The content of a radioactive isotope in an organ must be viewed as a random function for which the ratio of two independent incorporations, on the average by probability, corresponds to the ratio of the corresponding amounts of the isotope that have accumulated in the organism. This tenet determines the principle of similarity. Specifically, it follows from it that the distribution of the arbitrary amount in the organism with multiple repetition of the experiment will be subordinate to a log-normal law. Second, the vital condition for creating the quantitative statistical model of the metabolism is a large volume of experimental data. This requires perfection of the unified rapid methods of research

  15. NATO Advanced Study Institute International Advanced Course on The Liquid State and Its Electrical Properties

    CERN Document Server

    Christophorou, L; Luessen, L

    1988-01-01

    As the various disciplines of science advance, they proliferate and tend to become more esoteric. Barriers of specialized terminologies form, which cause scientists to lose contact with their colleagues, and differences in points-of-view emerge which hinder the unification of knowledge among the various disciplines, and even within a given discipline. As a result, the scientist, and especially the student, is in many instances offered fragmented glimpses of subjects that are funda­ mentally synthetic and that should be treated in their own right. Such seems to be the case of the liquid state. Unlike the other states of matter -- gases, solids, and plasmas -- the liquid state has not yet received unified treatment, probably because it has been the least explored and remains the least understood state of matter. Occasionally, events occur which help remove some of the barriers that separate scientists and disciplines alike. Such an event was the ASI on The Liquid State held this past July at the lovely Hotel T...

  16. High-performance liquid chromatographic separation of biologically important arsenic species utilizing on-line inductively coupled argon plasma atomic emission spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Spall, W.D.; Lynn, J.G.; Andersen, J.L.; Valdez, J.G.; Gurley, L.R.

    1986-06-01

    An anion exchange, high-performance liquid chromatography technique using a 15-min linear gradient from water to 0.5 M ammonium carbonate to separate arsenite, arsenate, methylarsonic acid, and dimethylarsinic acid from neutral arsenic containing compounds was developed for application to a study of arsenic metabolism in cultured cell suspensions. Arsenic detection was accomplished by the direct coupling of the column effluent to an inductively coupled argon plasma atomic emission spectrometer (ICAP-AES) set to monitor the arsenic emission line at 197.19 nm. The analysis requires 20 min and is sensitive to as low as 60 ng of arsenic injected to the column.

  17. On-line detection of illicit substances in liquid phase with proton-transfer-reaction mass spectrometry (PTR-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Juerschik, Simone; Agarwal, Bishu; Petersson, Fredrik [Institut fuer Ionenphysik und Angewandte Physik, Universitaet Innsbruck, Technikerstr. 25, 6020 Innsbruck (Austria); Sulzer, Philipp; Haidacher, Stefan; Jordan, Alfons; Schottkowsky, Ralf; Hartungen, Eugen; Hanel, Gernot; Seehauser, Hans; Maerk, Lukas [IONICON Analytik GmbH, Eduard-Bodem-Gasse 3, 6020 Innsbruck (Austria); Maerk, Tilmann D. [Institut fuer Ionenphysik und Angewandte Physik, Universitaet Innsbruck, Technikerstr. 25, 6020 Innsbruck (Austria); IONICON Analytik GmbH, Eduard-Bodem-Gasse 3, 6020 Innsbruck (Austria)

    2011-07-01

    The direct aqueous injection (DAI) technique was recently utilized for the detection of illicit substances in liquid phase. DAI turns out to be an ideal solution for direct analysis of liquid samples, since we can make good use of the outstanding advantages, such as real-time analysis, no sample preparation, low detection limits and short response time. Differences in TNT concentration in the water could be seen dependent on time and original size of the pieces and we could demonstrate a linear correlation between the concentration in liquid and the PTR-MS signal. Furthermore, we were also able to demonstrate that this method is capable of detecting minute traces of ''rape drugs'', i.e. {gamma}-butyrolactone and 1,4-butanediol, in liquids. This new method achieving sensitivities in the around 100 pptw range appears therefore well suited for the fight against drug crime and terrorism and for the evaluation of contamination of ammunition dumping sites.

  18. High-performance liquid chromatography–off line mass spectrometry analysis of anthraquinones produced by Geosmithia lavendula

    Czech Academy of Sciences Publication Activity Database

    Stodůlková, Eva; Man, Petr; Kolařík, Miroslav; Flieger, Miroslav

    2010-01-01

    Roč. 1217, č. 40 (2010), s. 6296-6302 ISSN 0021-9673 R&D Projects: GA MŠk 2B08064; GA AV ČR KAN200200651 Institutional research plan: CEZ:AV0Z50200510 Keywords : High-performance liquid chromatography * Mass spectrometry * Anthraquinone s Subject RIV: EE - Microbiology, Virology Impact factor: 4.194, year: 2010

  19. Sensory characteristics of liquids thickened with commercial thickeners to levels specified in the International Dysphagia Diet Standardization Initiative (IDDSI) framework.

    Science.gov (United States)

    Ong, Jane Jun-Xin; Steele, Catriona M; Duizer, Lisa M

    2018-06-01

    Sensory characteristics are important for the acceptance of thickened liquids, but those of liquids thickened to the new standards put forth by the International Dysphagia Diet Standardization Initiative (IDDSI) are unknown. This research sought to identify and rate the perception of important sensory properties of liquids thickened to levels specified in the IDDSI framework. Samples were made with water, with and without added barium sulfate, and were thickened with a cornstarch or xanthan gum based thickener. Samples were characterized using projective mapping/ultra-flash profiling to identify important sample attributes, and then with trained descriptive analysis panels to characterize those attributes in non-barium and barium thickened liquids. Three main groups of attributes were observed. Taste and flavor attributes decreased in intensity with increasing thickener. Thickener specific attributes included graininess and chalkiness for the cornstarch thickened samples, and slipperiness for the xanthan gum samples. Within the same type of thickener, ratings of thickness-related attributes (perceived viscosity, adhesiveness, manipulation, and swallowing) at different IDDSI levels were significantly different from each other. However, in non-barium samples, cornstarch samples were perceived as thicker than xanthan gum samples even though they had similar apparent viscosities at 50 s -1 . On the other hand, the two thickeners had similar perceived thickness in the barium samples even though the apparent viscosities of cornstarch samples were higher than those of the xanthan gum samples. In conclusion, IDDSI levels can be distinguished based on sensory properties, but these properties may be affected by the type of thickener and medium being thickened.

  20. Development of On-Line High Performance Liquid Chromatography (HPLC)-Biochemical Detection Methods as Tools in the Identification of Bioactives

    Science.gov (United States)

    Malherbe, Christiaan J.; de Beer, Dalene; Joubert, Elizabeth

    2012-01-01

    Biochemical detection (BCD) methods are commonly used to screen plant extracts for specific biological activities in batch assays. Traditionally, bioactives in the most active extracts were identified through time-consuming bio-assay guided fractionation until single active compounds could be isolated. Not only are isolation procedures often tedious, but they could also lead to artifact formation. On-line coupling of BCD assays to high performance liquid chromatography (HPLC) is gaining ground as a high resolution screening technique to overcome problems associated with pre-isolation by measuring the effects of compounds post-column directly after separation. To date, several on-line HPLC-BCD assays, applied to whole plant extracts and mixtures, have been published. In this review the focus will fall on enzyme-based, receptor-based and antioxidant assays. PMID:22489144

  1. Calibration transfer of a Raman spectroscopic quantification method for the assessment of liquid detergent compositions between two at-line instruments installed at two liquid detergent production plants.

    Science.gov (United States)

    Brouckaert, D; Uyttersprot, J-S; Broeckx, W; De Beer, T

    2017-09-01

    Calibration transfer of partial least squares (PLS) quantification models is established between two Raman spectrometers located at two liquid detergent production plants. As full recalibration of existing calibration models is time-consuming, labour-intensive and costly, it is investigated whether the use of mathematical correction methods requiring only a handful of standardization samples can overcome the dissimilarities in spectral response observed between both measurement systems. Univariate and multivariate standardization approaches are investigated, ranging from simple slope/bias correction (SBC), local centring (LC) and single wavelength standardization (SWS) to more complex direct standardization (DS) and piecewise direct standardization (PDS). The results of these five calibration transfer methods are compared reciprocally, as well as with regard to a full recalibration. Four PLS quantification models, each predicting the concentration of one of the four main ingredients in the studied liquid detergent composition, are aimed at transferring. Accuracy profiles are established from the original and transferred quantification models for validation purposes. A reliable representation of the calibration models performance before and after transfer is thus established, based on β-expectation tolerance intervals. For each transferred model, it is investigated whether every future measurement that will be performed in routine will be close enough to the unknown true value of the sample. From this validation, it is concluded that instrument standardization is successful for three out of four investigated calibration models using multivariate (DS and PDS) transfer approaches. The fourth transferred PLS model could not be validated over the investigated concentration range, due to a lack of precision of the slave instrument. Comparing these transfer results to a full recalibration on the slave instrument allows comparison of the predictive power of both Raman

  2. Predictors of Sun Protection Behaviours and Severe Sunburn inan International on-line study

    Science.gov (United States)

    Bränström, Richard; Kasparian, Nadine A.; Chang, Yu-mei; Affleck, Paul; Tibben, Aad; Aspinwall, Lisa G.; Azizi, Esther; Baron-Epel, Orna; Battistuzzi, Linda; Bergman, Wilma; Bruno, William; Chan, May; Cuellar, Francisco; Dębniak, Tadeusz; Pjanova, Dace; Ertmański, Sƚawomir; Figl, Adina; Gonzalez, Melinda; Hayward, Nicholas K.; Hocevar, Marko; Kanetsky, Peter A.; Leachman, Sancy A.; Heisele, Olita; Palmer, Jane; Peric, Barbara; Puig, Susana; Schadendorf, Dirk; Gruis, Nelleke A.; Newton-Bishop, Julia; Brandberg, Yvonne

    2013-01-01

    Background The incidence of melanoma continues to increase in many countries, and primary prevention of melanoma includes avoidance of sunburn as well as adequate sun protection behaviour. The aim of this study was to examine the prevalence of self-reported sun protection behaviours and sunburn in users of the Internet, and to identify the demographic, clinical and attitudinal/motivational correlates of sun protection behaviours. Methods Self-report data were gathered on behalf of GenoMEL (www.genomel.org) using an online survey available in 10 different languages, and 8,178 individuals successfully completed at least 80% of survey items, with 73% of respondents from Europe, 12% from Australia, 7% from the USA, 2% from Israel, and 6% from other countries. Results Half of all respondents and 27% of those with a previous melanoma reported at least one severe sunburn during the previous 12 months. The strongest factors associated with sun protection behaviour were perceived barriers to protection (β=−0.44/β=−0.37), and respondents who reported a positive attitude towards suntans were less likely to protect (β=−0.16/β=−0.14). Reported use of protective clothing and shade, as well as avoidance of midday sun exposure, were more strongly related to reduced risk of sunburn than sunscreen use. Conclusions Despite widespread dissemination of public health messages about the importance of sun protection, a substantial proportion of this international sample, including respondents with a previous melanoma, reported inadequate sun protection behaviours resulting in severe sunburn. Impact Future strategies to decrease sunburn should target the practical, social and psychological barriers associated with non-uptake of sun protection. PMID:20643826

  3. An on-line push/pull perfusion-based hollow-fiber liquid-phase microextraction system for high-performance liquid chromatographic determination of alkylphenols in water samples.

    Science.gov (United States)

    Chao, Yu-Ying; Jian, Zhi-Xuan; Tu, Yi-Ming; Wang, Hsaio-Wen; Huang, Yeou-Lih

    2013-06-07

    In this study, we employed a novel on-line method, push/pull perfusion hollow-fiber liquid-phase microextraction (PPP-HF-LPME), to extract 4-tert-butylphenol, 2,4-di-tert-butylphenol, 4-n-nonylphenol, and 4-n-octylphenol from river and tap water samples; we then separated and quantified the extracted analytes through high-performance liquid chromatography (HPLC). Using this approach, we overcame the problem of fluid loss across the porous HF membrane to the donor phase, permitting on-line coupling of HF-LPME to HPLC. In our PPP-HF-LPME system, we used a push/pull syringe pump as the driving source to perfuse the acceptor phase, while employing a heating mantle and an ultrasonic probe to accelerate mass transfer. We optimized the experimental conditions such as the nature of the HF supported intermediary phase and the acceptor phase, the composition of the donor and acceptor phases, the sample temperature, and the sonication conditions. Our proposed method provided relative standard deviations of 3.1-6.2%, coefficients of determination (r(2)) of 0.9989-0.9998, and limits of detection of 0.03-0.2 ng mL(-1) for the analytes under the optimized conditions. When we applied this method to analyses of river and tap water samples, our results confirmed that this microextraction technique allows reliable monitoring of alkylphenols in water samples.

  4. Purification of lignans from Fructus Arctii using off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography.

    Science.gov (United States)

    Yang, Bichao; Xin, Huaxia; Wang, Feier; Cai, Jianfeng; Liu, Yanfang; Fu, Qing; Jin, Yu; Liang, Xinmiao

    2017-08-01

    As a common traditional Chinese medicine, Fructus Arctii has important clinical medical values. Its main components are lignans, which are difficult to separate and analyze because of the complex composition, similar chemical structures, and close properties. In this study, an off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method, as well as an effective sample pretreatment method based on hydrophilic interaction chromatography material, was developed to enrich the minor lignan fractions and obtain high-purity compounds. In total, 12 high-purity compounds were isolated from Fructus Arctii. Their structures were identified by using high-resolution mass spectrometry and nuclear magnetic resonance spectroscopy, which showed that all were lignans and that most of them were isomers. The results demonstrated the effective off-line two-dimensional supercritical fluid chromatography/reversed-phase liquid chromatography method for the purification of lignans from Fructus Arctii. The separation protocol established here will be beneficial for the separation of complex samples from other kinds of natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. RAS testing of liquid biopsy correlates with the outcome of metastatic colorectal cancer patients treated with first-line FOLFIRI plus cetuximab in the CAPRI-GOIM trial.

    Science.gov (United States)

    Normanno, N; Esposito Abate, R; Lambiase, M; Forgione, L; Cardone, C; Iannaccone, A; Sacco, A; Rachiglio, A M; Martinelli, E; Rizzi, D; Pisconti, S; Biglietto, M; Bordonaro, R; Troiani, T; Latiano, T P; Giuliani, F; Leo, S; Rinaldi, A; Maiello, E; Ciardiello, F

    2018-01-01

    Liquid biopsy is an alternative to tissue for RAS testing in metastatic colorectal carcinoma (mCRC) patients. Little information is available on the predictive role of liquid biopsy RAS testing in patients treated with first-line anti-EGFR monoclonal antibody-based therapy. In the CAPRI-GOIM trial, 340 KRAS exon-2 wild-type mCRC patients received first-line cetuximab plus FOLFIRI. Tumor samples were retrospectively assessed by next generation sequencing (NGS). Baseline plasma samples were analyzed for KRAS and NRAS mutations using beads, emulsion, amplification, and magnetics digital PCR (BEAMing). Discordant cases were solved by droplet digital PCR (ddPCR) or deep-sequencing. A subgroup of 92 patients with available both NGS data on tumor samples and baseline plasma samples were included in this study. Both NGS analysis of tumor tissue and plasma testing with BEAMing identified RAS mutations in 33/92 patients (35.9%). However, 10 cases were RAS tissue mutant and plasma wild-type, and additional 10 cases were tissue wild-type and plasma mutant, resulting in a concordance rate of 78.3%. Analysis of plasma samples with ddPCR detected RAS mutations in 2/10 tissue mutant, plasma wild-type patients. In contrast, in all tissue wild-type and plasma mutant cases, ddPCR or deep-sequencing analysis of tumor tissue confirmed the presence of RAS mutations at allelic frequencies ranging between 0.15% and 1.15%. The median progression-free survival of RAS mutant and wild-type patients according to tissue (7.9 versus 12.6 months; P = 0.004) and liquid biopsy testing (7.8 versus 13.8 moths; P < 0.001) were comparable. Similar findings were observed for the median overall survival of RAS mutant and wild-type patients based on tissue (22.1 versus 35.8 months; P = 0.016) and plasma (19.9 versus 35.8 months; P = 0.013) analysis. This study indicates that RAS testing of liquid biopsy results in a similar outcome when compared with tissue testing in mCRC patients

  6. In-line UV spectroscopy for the quantification of low-dose active ingredients during the manufacturing of pharmaceutical semi-solid and liquid formulations.

    Science.gov (United States)

    Bostijn, N; Hellings, M; Van Der Veen, M; Vervaet, C; De Beer, T

    2018-07-12

    UltraViolet (UV) spectroscopy was evaluated as an innovative Process Analytical Technology (PAT) - tool for the in-line and real-time quantitative determination of low-dosed active pharmaceutical ingredients (APIs) in a semi-solid (gel) and a liquid (suspension) pharmaceutical formulation during their batch production process. The performance of this new PAT-tool (i.e., UV spectroscopy) was compared with an already more established PAT-method based on Raman spectroscopy. In-line UV measurements were carried out with an immersion probe while for the Raman measurements a non-contact PhAT probe was used. For both studied formulations, an in-line API quantification model was developed and validated per spectroscopic technique. The known API concentrations (Y) were correlated with the corresponding in-line collected preprocessed spectra (X) through a Partial Least Squares (PLS) regression. Each developed quantification method was validated by calculating the accuracy profile on the basis of the validation experiments. Furthermore, the measurement uncertainty was determined based on the data generated for the determination of the accuracy profiles. From the accuracy profile of the UV- and Raman-based quantification method for the gel, it was concluded that at the target API concentration of 2% (w/w), 95 out of 100 future routine measurements given by the Raman method will not deviate more than 10% (relative error) from the true API concentration, whereas for the UV method the acceptance limits of 10% were exceeded. For the liquid formulation, the Raman method was not able to quantify the API in the low-dosed suspension (0.09% (w/w) API). In contrast, the in-line UV method was able to adequately quantify the API in the suspension. This study demonstrated that UV spectroscopy can be adopted as a novel in-line PAT-technique for low-dose quantification purposes in pharmaceutical processes. Important is that none of the two spectroscopic techniques was superior to the other

  7. On-line monitoring of in-vitro oral bioaccessibility tests as front-end to liquid chromatography for determination of chlorogenic acid isomers in dietary supplements.

    Science.gov (United States)

    Kremr, Daniel; Cocovi-Solberg, David J; Bajerová, Petra; Ventura, Karel; Miró, Manuel

    2017-05-01

    A novel fully automated in-vitro oral dissolution test assay as a front-end to liquid chromatography has been developed and validated for on-line chemical profiling and monitoring of temporal release profiles of three caffeoylquinic acid (CQA) isomers, namely, 3-CQA,4-CQA and 5-CQA, known as chlorogenic acids, in dietary supplements. Tangential-flow filtration is harnessed as a sample processing approach for on-line handling of CQA containing extracts of hard gelatin capsules and introduction of protein-free samples into the liquid chromatograph. Oral bioaccessibility/dissolution test assays were performed at 37.0±0.5°C as per US Pharmacopeia recommendations using pepsin with activity of ca. 749,000 USP units/L in 0.1mol/L HCl as the extraction medium and a paddle apparatus stirred at 50rpm. CQA release rates and steady-state dissolution conditions were determined accurately by fitting the chromatographic datasets, namely, the average cumulative concentrations of bioaccessible pools of every individual isomer monitored during 200min, with temporal resolutions of ≥10min, to a first-order dissolution kinetic model. Distinct solid-to-liquid phase ratios in the mimicry of physiological extraction conditions were assessed. Relative standard deviations for intra-day repeatability and inter-day intermediate precision of 5-CQA within the 5-40µg/mL concentration range were <3.4% and <5.5%, respectively. Trueness of the automatic flow method for determination of 5-CQA released from dietary supplements in gastric fluid surrogate was demonstrated by spike recoveries, spanning from 91.5-104.0%, upon completion of the dissolution process. The proposed hyphenated setup was resorted for evaluating potential differences in dissolution profiles and content of the three most abundant chlorogenic acid isomers in dietary supplements from varied manufacturers. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. International bioenergy trade - a review of past developments in the liquid biofuels market

    NARCIS (Netherlands)

    Lamers, P.; Hamelinck, C.N.; Junginger, H.M.|info:eu-repo/dai/nl/202130703; Faaij, A.P.C.|info:eu-repo/dai/nl/10685903X

    2011-01-01

    Policies aimed to promote biofuels locally had tremendous effects on global market developments across the past decade. This article develops insights into the interaction of these policies and market forces via a comprehensive collection and analysis of international production and trade data. It

  9. On-line combination of liquid chromatography and capillary gas chromatography : preconcentration and analysis of organic compounds in aqueous samples

    NARCIS (Netherlands)

    Noij, T.H.M.; Weiss, E.; Herps, T.; Cruchten, van H.; Rijks, J.A.

    1988-01-01

    This paper describes the design of a new, versatile, and low-cost on-line LC-GC interface that allows the fast and reliable introduction of large sample volumes onto a capillary GC column. The sample introduction procedure consists successively of: evaporation of the entire sample (LC fraction),

  10. New on-line separation workflow of microbial metabolites via hyphenation of analytical and preparative comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun

    2016-10-15

    Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Heat transfer of liquid-metal magnetohydrodynamic flow with internal heat generation

    International Nuclear Information System (INIS)

    Kumamaru, Hiroshige; Kurita, Kazuhisa; Kodama, Satoshi

    2000-01-01

    Numerical calculations on heat transfer of a magnetohydrodynamic (MHD) flow with internal heat generation in a rectangular channel have been performed for the cases of very-large Hartmann numbers, finite wall conductivities and small aspect ratio (i.e. small length ratios of the channel side perpendicular to the applied magnetic field and the side parallel to the field), simulating typical conditions for a fusion-reactor blanket. The Nusselt numbers of the MHD flow in rectangular channels with aspect ratios of 1/10 to 1/40 for Hartmann numbers of ∼5 x 10 5 become ∼10 times higher than those for the corresponding flow under no magnetic field. The Nusselt number becomes higher as the internal heat generation rate increases as far as the heat generation rates in a fusion reactor blanket are considered. (author)

  12. Analysis of epoxyeicosatrienoic acids by chiral liquid chromatography/electron capture atmospheric pressure chemical ionization mass spectrometry using [13C]-analog internal standards

    Science.gov (United States)

    Mesaros, Clementina; Lee, Seon Hwa; Blair, Ian A.

    2012-01-01

    The metabolism of arachidonic acid (AA) to epoxyeicosatrienoic acids (EETs) is thought to be mediated primarily by the cytochromes P450 (P450s) from the 2 family (2C9, 2C19, 2D6, and 2J2). In contrast, P450s of the 4 family are primarily involved in omega oxidation of AA (4A11 and 4A22). The ability to determine enantioselective formation of the regioisomeric EETs is important in order to establish their potential biological activities and to asses which P450 isoforms are involved in their formation. It has been extremely difficult to analyze individual EET enantiomers in biological fluids because they are present in only trace amounts and they are extremely difficult to separate from each other. In addition, the deuterium-labeled internal standards that are commonly used for stable isotope dilution liquid chromatography/mass spectrometry (LC/MS) analyses have different LC retention times when compared with the corresponding protium forms. Therefore, quantification by LC/MS-based methodology can be compromised by differential suppression of ionization of the closely eluting isomers. We report the preparation of [13C20]-EET analog internal standards and the use of a validated high-sensitivity chiral LC/electron capture atmospheric pressure chemical ionization (ECAPCI)-MS method for the trace analysis of endogenous EETs as their pentafluorobenzyl (PFB) ester derivatives. The assay was then used to show the exquisite enantioselectivity of P4502C19-, P4502D6-, P4501A1-, and P4501B1-mediated conversion of AA into EETs and to quantify the enantioselective formation of EETs produced by AA metabolism in a mouse epithelial hepatoma (Hepa) cell line. PMID:20972997

  13. Determination of avermectins by the internal standard recovery correction - high performance liquid chromatography - quantitative Nuclear Magnetic Resonance method.

    Science.gov (United States)

    Zhang, Wei; Huang, Ting; Li, Hongmei; Dai, Xinhua; Quan, Can; He, Yajuan

    2017-09-01

    Quantitative Nuclear Magnetic Resonance (qNMR) is widely used to determine the purity of organic compounds. For the compounds with lower purity especially molecular weight more than 500, qNMR is at risk of error for the purity, because the impurity peaks are likely to be incompletely separated from the peak of major component. In this study, an offline ISRC-HPLC-qNMR (internal standard recovery correction - high performance liquid chromatography - qNMR) was developed to overcome this problem. It is accurate by excluding the influence of impurity; it is low-cost by using common mobile phase; and it extends the applicable scope of qNMR. In this method, a mix solution of the sample and an internal standard was separated by HPLC with common mobile phases, and only the eluents of the analyte and the internal standard were collected in the same tube. After evaporation and re-dissolution, it was determined by qNMR. A recovery correction factor was determined by comparison of the solutions before and after these procedures. After correction, the mass fraction of analyte was constant and it was accurate and precise, even though the sample loss varied during these procedures, or even in bad resolution of HPLC. Avermectin B 1 a with the purity of ~93% and the molecular weight of 873 was analyzed. Moreover, the homologues of avermectin B 1 a were determined based on the identification and quantitative analysis by tandem mass spectrometry and HPLC, and the results were consistent with the results of traditional mass balance method. The result showed that the method could be widely used for the organic compounds, and could further promote qNMR to become a primary method in the international metrological systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kai-Ta; Liu, Pei-Han [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Urban, Pawel L. [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China)

    2015-09-24

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h{sup −1}). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates

  15. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    International Nuclear Information System (INIS)

    Hsieh, Kai-Ta; Liu, Pei-Han; Urban, Pawel L.

    2015-01-01

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h"−"1). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates the

  16. An EPR line shape study of anisotropic rotational reorientation and slow tumbling in liquid and frozen jojoba oil

    Science.gov (United States)

    Hwang, J. S.; Al-Rashid, W. A.

    Spin probe investigation of jojoba oil was carried out by electron paramagnetic rresonance (EPR) spectroscopy. The spin probe used was 2,2,6,6-tetramethyl-4-piperidone- N-oxide. The EPR line shape studies were carried out in the lower temperature range of 192 to 275 K to test the applicability of the stochastic Liouville theory in the simulation of EPR line shapes where earlier relaxation theories do not apply. In an earlier study, this system was analysed by employing rotational diffusion at the fast-motional region. The results show that PD-Tempone exhibits asymmetric rotational diffusion with N = 3.3 at an axis z'= Y in the plane of the molecule and perpendicular to the NO bond direction. In this investigation we have extended the temperature range to lower temperatures and observed slow tumbling EPR spectra. It is shown that the stochastic Liouville method can be used to simulate all but two of the experimentally observed EPR spectra in the slow-motional region and details of the slow-motional line shape are sensitive to the anisotropy of rotation and showed good agreement for a moderate jump model. From the computer simulation of EPR line shapes it is found that the information obtained on τ R, and N in the motional-narrowing region can be extrapolated into the slow-tumbling region. It is also found that ln (τ R) is linear in 1/ T in the temperature range studied and the resulting activation energy for rotation is 51 kJ/mol. The two EPR spectra at 240 and 231 K were found to exhibit the effects of anisotropic viscosity observed by B IRELL for nitroxides oriented in tubular cavities in inclusion crystals in which the molecule is free to rotate about the long axis but with its rotation hindered about the other two axes because of the cavity geometry. These results proved that the slow-tumbling spectra were very sensitive to the effects of anisotropy in the viscosity.

  17. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  18. Liquid chromatography mass spectrometry determination of perfluoroalkyl acids in environmental solid extracts after phospholipid removal and on-line turbulent flow chromatography purification.

    Science.gov (United States)

    Mazzoni, M; Polesello, S; Rusconi, M; Valsecchi, S

    2016-07-01

    An on-line TFC (Turbulent Flow Chromatography) clean up procedures coupled with UHPLC-MS/MS (Ultra High Performance Liquid Chromatography Mass Spectrometry) multi-residue method was developed for the simultaneous determination of 8 perfluroalkyl carboxylic acids (PFCA, from 5 to 12 carbon atoms) and 3 perfluoroalkyl sulfonic acids (PFSA, from 4 to 8 carbon atoms) in environmental solid matrices. Fast sample preparation procedure was based on a sonication-assisted extraction with acetonitrile. Phospholipids in biological samples were fully removed by an off-line SPE purification before injection, using HybridSPE(®) Phospholipid Ultra cartridges. The development of the on-line TFC clean-up procedure regarded the choice of the stationary phase, the optimization of the mobile phase composition, flow rate and injected volume. The validation of the optimized method included the evaluation of matrix effects, accuracy and reproducibility. Signal suppression in the analysis of fortified extracts ranged from 1 to 60%, and this problem was overcome by using isotopic dilution. Since no certified reference materials were available for PFAS in these matrices, accuracy was evaluated by recoveries on spiked clam samples which were 98-133% for PFCAs and 40-60% for PFSAs. MLDs and MLQs ranged from 0.03 to 0.3ngg(-1) wet weight and from 0.1 to 0.9ngg(-1) wet weight respectively. Repeatability (intra-day precision) and reproducibility (inter-day precision) showed RSD from 3 to 13% and from 4 to 27% respectively. Validated on-line TFC/UHPLC-MS/MS method has been applied for the determination of perfluoroalkyl acids in different solid matrices (sediment, fish, bivalves and bird yolk). Copyright © 2016 Elsevier B.V. All rights reserved.

  19. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  20. Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

    Science.gov (United States)

    Wada, Mitsuhiro; Inoue, Keiyu; Thara, Ayuko; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2003-02-14

    A HPLC method was developed for the simultaneous determination of organic peroxides and hydrogen peroxide with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Organic peroxides [i.e., benzoyl peroxide (BP), tert.-butyl hydroperoxide (BHP), tert.-butyl perbenzoate (BPB), cumene hydroperoxide (CHP)] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide, which was determined by PO-CL detection. The conditions for UV irradiation and PO-CL detection were optimized by a flow injection analysis (FIA) system. Generation of hydrogen peroxide from peroxides with on-line UV irradiation also was confirmed by the FIA system by incorporating an enzyme column reactor immobilized with catalase. The separation of four organic peroxides and hydrogen peroxide by HPLC was accomplished isocratically on an ODS column within 30 min. The detection limits (signal-to-noise ratio=3) were 1.1 microM for hydrogen peroxide, 6.8 microM for BP, 31.3 microM for BHP, 7.5 microM for BPB and 1.3 microM for CHP. The proposed method was applied to the determination of BP in wheat flour.

  1. Application of point-to-point matching algorithms for background correction in on-line liquid chromatography-Fourier transform infrared spectrometry (LC-FTIR).

    Science.gov (United States)

    Kuligowski, J; Quintás, G; Garrigues, S; de la Guardia, M

    2010-03-15

    A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08%, v/v TFA):water (0.08%, v/v TFA) gradients with compositions ranging from 35 to 85% (v/v) acetonitrile, giving accurate results for both, baseline resolved and overlapped peaks. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  2. Determination of organic and inorganic mercury species in Sungai Kinta, Perak by reversed-phase high performance liquid chromatography (HPLC) on-line coupled with ICP-MS

    International Nuclear Information System (INIS)

    Norshidah Baharuddin; Norashikin Saim; Rozita Osman; Sharifuddin Mohd Zain

    2012-01-01

    This paper describes a simple method for mercury speciation in river water samples of Sungai Kinta, Perak. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ ICP-MS). Separation of mercury species was accomplished within 6 minutes on an AQ C18 4.6 mm i.d x 150 mm, 5 μm reversed phase column with 0.1 % (w/ v) L-cysteine as mobile phase. Under the optimum instrumental conditions, recoveries of 101-104 % for MeHg + and 96 - 104 % for Hg 2+ were obtained with experimental detection limits of 1ngL -1 for inorganic mercury and 1.5 μgL -1 for organic mercury. (author)

  3. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  4. Hyphenating size‐exclusion chromatography with electrospray mass spectrometry; using on‐line liquid‐liquid extraction to study the lipid composition of lipoprotein particles

    Science.gov (United States)

    Osei, Michael; Griffin, Julian L.

    2015-01-01

    Rationale Lipoproteins belong to the most commonly measured clinical biochemical parameters. Lipidomics is an orthogonal approach and aims to profile the individual lipid molecules that jointly form the lipoprotein particles. However, in the first step of the extraction of lipid molecules from serum, an organic solvent is used leading to dissociation of the lipoproteins. Thus far it has been impossible to combine lipidomics and lipoprotein analysis in one analytical system. Methods Human plasma was diluted in phosphate‐buffered saline (PBS) and injected onto a Superose 6 PC 3.2 column with PBS as a mobile phase to separate lipoproteins. The eluent was led to a Syrris FLLEX module, which also received CHCl3/MeOH (3:1). The two phases were mixed and subsequently separated using a Teflon membrane in an especially designed pressurized flow chamber. The organic phase was led to a standard electrospray source of an Orbitrap mass spectrometer. Results Size‐exclusion chromatography (SEC) has been commonly applied to separate lipoproteins and is considered a practical alternative to ultracentrifugation. Through the on‐line liquid‐liquid extraction method it becomes possible to obtained detailed mass spectra of lipids across different lipoprotein fractions. The extracted ion chromatograms of specific lipid signals showed their distribution against the size of lipoprotein particles. Conclusions The application of on‐line liquid‐liquid extraction allows for the continuous electrospray‐based mass spectral analysis of SEC eluent, providing the detailed lipid composition of lipoprotein particles separated by size. This approach provides new possibilities for the study of the biochemistry of lipoproteins. © 2015 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. PMID:26443395

  5. Analysis of hydroxamate siderophores in soil solution using liquid chromatography with mass spectrometry and tandem mass spectrometry with on-line sample preconcentration.

    Science.gov (United States)

    Olofsson, Madelen A; Bylund, Dan

    2015-10-01

    A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid–liquid microextraction coupled with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Anthemidis, Aristidis N.; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D.

    2012-01-01

    Highlights: ► A dispersive liquid–liquid micro extraction method for lead and copper determination. ► A micro-volume transportation system for extractant solvent lighter than water. ► Analysis of natural water samples. - Abstract: A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L −1 and 3.3% for lead and 0.12 μg L −1 and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples.

  7. Utility of reversed phase high performance liquid chromatography for on-line yield determination of radiochemical separations: Studies with cobalt

    International Nuclear Information System (INIS)

    Subramanian, S.; Woittiez, J.R.W.

    1993-01-01

    This article indicates the potentials of high performance liquid chromatography (HPLC) as a radiochemical technique for multielement separation of neutron irradiated samples. The focus lies on the convenience to use the detector signal of the eluted components to indicate the chemical yield of the analyte, which has often proved to be a crucial step in radiochemical separations. Two signals have been utilized. The UV signal of the metal-ligand complexes separated by reversed phase HPLC and the radioactive response as a result of sample irradiation of carrier-tracer addition. Change in ratio is discussed between the two signals, if any, for a specific sample. Losses of metal as much as 65% were simulated and corrected using the individual UV response. The method promises improved accuracy for elemental analysis despite losses suffered during the various chemical steps. The procedure omits the necessity of additional analytical steps for yield determination. The present article aims at the chromatographic part of the study. Cobalt as cobalt diethyldithiocarbamate has been used to demonstrate the viability of the concept. The separation was developed on c C18 reverse phase analytical column and optimized on a semi preparative one

  8. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  9. Heat transfer measurements of internally heated liquids in cylindrical convection cells

    International Nuclear Information System (INIS)

    Fieg, G.

    1978-10-01

    In hypothetical reactor accidents, the thermohydraulic behaviour of core melts heated by the after-heat must be analyzed. For this purpose model experiments have been performed to study the stationary, natural convective heat transfer of internally heated fluids in cylindrical convertion cells investigating also the influence of geometry (aspect ratio) as well as of difference thermal wall conditions on to the heat transport characteristics. Axial temperature profiles, local heat flux densities at the vertical walls and their dependence, on the external Rayleigh number ar in detail reported, besides the Nusselt vs Rayleigh correlations for the aspect ratios HID=1 and 0,25. The results of these experiments are compared, as for ar possible, with existing thermohydraulic codes and simpler model asoumptions like the zone-model of Baker et. al. and after experimental verification, be used to study realistic PAHR situations. Velocity measurements by means of Laser-Doppler-Method yield information about the flow characteristics near the vertical walls and within the central part of the convecting fluid. (GL) [de

  10. Quantitation of biological retinoids by high-pressure liquid chromatography: primary internal standardization using tritiated retinoids

    International Nuclear Information System (INIS)

    Cullum, M.E.; Zile, M.H.

    1986-01-01

    A single method is described for quantitation of 14 retinoids found in biological material. The method consists of reversed-phase HPLC, internal standardization, and carrier extraction procedures with three synthetic retinoids. Primary standardization of HPLC uv detector is achieved using tritiated all-trans-retinoic acid, all-trans-retinol, all-trans-retinyl palmitate, and all-trans-retinyl acetate. Extraction methods are standardized by correlating the uv absorbance of retinoids at 340 nm with radioactivity of tritiated retinoids of known specific activity. Quantitation of 10 pg of tritiated or 5 ng of nonradioactive retinoid per 0.1 g sample in a polarity range from 4-oxo-retinoic acid to retinyl stearate can be achieved in a single, 50-min chromatographic run. A single HPLC pump, a C 18 reversed-phased analytical column, a multistep three-solvent gradient, and inexpensive solvents based on methanol, water, and chloroform comprise this cost-effective chromatographic system. Our primary standardization method allows investigators employing different procedures to compare results between laboratories by standardizing the HPLC uv detector with commercially available tritiated retinoids. With this method we were able to quantitate nanomolar amounts of endogenous retinoic acids and retinyl esters, that HPLC uv only conditions usually would not detect in the circulation and liver of rats under physiological conditions

  11. Hydrodynamics and heat transfer in reactor components cooled by liquid metal coolants in single/two phase. 11. meeting of the International Association for Hydraulic Research (IAHR) Working Group. Working material

    International Nuclear Information System (INIS)

    2005-01-01

    This Working Material includes the papers presented at the International Meeting 'Hydrodynamics and heat transfer in reactor components cooled by liquid metal coolants in single/two-phase', which was held 5-9 July 2004 at the State Scientific Center of Russian Federation - Institute for Physics and Power Engineering named after A.I. Leypunsky, in Obninsk near Moscow. The objectives of the meeting were to discuss new results obtained in the field of liquid metal coolant and to recommend the lines of further general physics and applied investigations, with the purpose of validating existing and codes under development for liquid metal cooled advanced and new generation nuclear reactors. Most of the contributions present results of experimental and numerical investigations into velocity, temperature and heat transfer in fuel subassemblies of fast reactors cooled by sodium or lead. In the frame of the meeting a benchmark problem devoted to heat transfer in the model subassembly of the fast reactor BREST-OD-300 was proposed. Experts from 5 countries (Japan, Netherlands, Spain, Republic of Korea, and Russia) took part in this benchmark exercise. The results of the benchmark calculations are summarized in the Working Material. The results of hydrodynamic studies of pressure head chambers and collector systems of liquid metal cooled reactors are presented in a number of papers. Also attention was given to the generalization of experimental data on hydraulic losses in the pipelines in case of mutual influence of local pressure drops, and to the modeling of natural convection in the fuel subassemblies and circuits with liquid metal cooling. Special emphasis at the meeting was placed on thermal hydraulics issues related to the development and design of target systems, such as heat removal in the target unit of the cascade subcritical reactor cooled by liquid salt; the target complex MK-1 for accelerator driven systems cooled by eutectic lead-bismuth alloy; and the test

  12. Hydrodynamics and heat transfer in reactor components cooled by liquid metal coolants in single/two phase. 11. meeting of the International Association for Hydraulic Research (IAHR) Working Group. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This Working Material includes the papers presented at the International Meeting 'Hydrodynamics and heat transfer in reactor components cooled by liquid metal coolants in single/two-phase', which was held 5-9 July 2004 at the State Scientific Center of Russian Federation - Institute for Physics and Power Engineering named after A.I. Leypunsky, in Obninsk near Moscow. The objectives of the meeting were to discuss new results obtained in the field of liquid metal coolant and to recommend the lines of further general physics and applied investigations, with the purpose of validating existing and codes under development for liquid metal cooled advanced and new generation nuclear reactors. Most of the contributions present results of experimental and numerical investigations into velocity, temperature and heat transfer in fuel subassemblies of fast reactors cooled by sodium or lead. In the frame of the meeting a benchmark problem devoted to heat transfer in the model subassembly of the fast reactor BREST-OD-300 was proposed. Experts from 5 countries (Japan, Netherlands, Spain, Republic of Korea, and Russia) took part in this benchmark exercise. The results of the benchmark calculations are summarized in the Working Material. The results of hydrodynamic studies of pressure head chambers and collector systems of liquid metal cooled reactors are presented in a number of papers. Also attention was given to the generalization of experimental data on hydraulic losses in the pipelines in case of mutual influence of local pressure drops, and to the modeling of natural convection in the fuel subassemblies and circuits with liquid metal cooling. Special emphasis at the meeting was placed on thermal hydraulics issues related to the development and design of target systems, such as heat removal in the target unit of the cascade subcritical reactor cooled by liquid salt; the target complex MK-1 for accelerator driven systems cooled by eutectic lead-bismuth alloy; and the test

  13. PEGylation of Phytantriol-Based Lyotropic Liquid Crystalline Particles-The Effect of Lipid Composition, PEG Chain Length, and Temperature on the Internal Nanostructure

    DEFF Research Database (Denmark)

    Nilsson, Christa; Ostergaard, Jesper; Larsen, Susan Weng

    2014-01-01

    of these lipidic nonlamellar liquid crystalline particles by using DSPE-mPEGs with three different block lengths of the hydrophilic PEG segment. The effects of lipid composition, PEG chain length, and temperature on the morphology and internal nanostructure of these self-assembled lipidic aqueous dispersions based...

  14. Multiphase Transport in Porous Media: Gas-Liquid Separation Using Capillary Pressure Gradients International Space Station (ISS) Flight Experiment Development

    Science.gov (United States)

    Wheeler, Richard R., Jr.; Holtsnider, John T.; Dahl, Roger W.; Deeks, Dalton; Javanovic, Goran N.; Parker, James M.; Ehlert, Jim

    2013-01-01

    Advances in the understanding of multiphase flow characteristics under variable gravity conditions will ultimately lead to improved and as of yet unknown process designs for advanced space missions. Such novel processes will be of paramount importance to the success of future manned space exploration as we venture into our solar system and beyond. In addition, because of the ubiquitous nature and vital importance of biological and environmental processes involving airwater mixtures, knowledge gained about fundamental interactions and the governing properties of these mixtures will clearly benefit the quality of life here on our home planet. The techniques addressed in the current research involving multiphase transport in porous media and gas-liquid phase separation using capillary pressure gradients are also a logical candidate for a future International Space Station (ISS) flight experiment. Importantly, the novel and potentially very accurate Lattice-Boltzmann (LB) modeling of multiphase transport in porous media developed in this work offers significantly improved predictions of real world fluid physics phenomena, thereby promoting advanced process designs for both space and terrestrial applications.This 3-year research effort has culminated in the design and testing of a zero-g demonstration prototype. Both the hydrophilic (glass) and hydrophobic (Teflon) media Capillary Pressure Gradient (CPG) cartridges prepared during the second years work were evaluated. Results obtained from ground testing at 1-g were compared to those obtained at reduced gravities spanning Martian (13-g), Lunar (16-g) and zero-g. These comparisons clearly demonstrate the relative strength of the CPG phenomena and the efficacy of its application to meet NASAs unique gas-liquid separation (GLS) requirements in non-terrestrial environments.LB modeling software, developed concurrently with the zero-g test effort, was shown to accurately reproduce observed CPG driven gas-liquid separation

  15. Proceedings of the international workshop on the technology and thermal hydraulics of heavy liquid metals (Hg, Pb, Bi, and their eutectics)

    International Nuclear Information System (INIS)

    Appleton, B.R.; Bauer, G.S.

    1996-06-01

    The International Workshop on the Technology and Thermal Hydraulics of Heavy Liquid Metals (Schruns Workshop) was organized to assess the R ampersand D and technology problems associated with designing and building a heavy liquid metal target for a spallation neutron source. The European scientific community is completing a feasibility study for a future, accelerator-based, pulsed spallation neutron source that would deliver a beam power of 5 megawatts (MW) to a target. They have concluded that a liquid metal target is preferable to conventional solid targets for handling the extreme radiation environments, high heat loads, and pulsed power. Similarly, the ORNL has been funded by the DOE to design a high-power, pulsed spallation neutron source that would begin operation at about 1 MW but that could be upgraded to significantly higher powers in the future. Again, the most feasible target design appears to be a liquid metal target. Since the expertise needed to consider these problems resides in a number of disparate disciplines not normally covered by existing conferences, this workshop was organized to bring a small number of scientists and engineers together to assess the opportunities for building such a target. The objectives and goals of the Schruns Workshop were to: review and share existing information on the science and technology of heavy liquid metal systems. Evaluate the opportunities and limitations of materials compatibility, thermal hydraulics and heat transfer, chemical reactions, corrosion, radiation effects, liquid-gas mixtures, systems designs, and circuit components for a heavy liquid metal target. Establish the critical R ampersand D and technology that is necessary to construct a liquid metal target. Explore opportunities for cooperative R ampersand D among members of the international community that could expedite results, and share expertise and resources. Selected papers are indexed separately for inclusion in the Energy Science and

  16. Proceedings of the international workshop on the technology and thermal hydraulics of heavy liquid metals (Hg, Pb, Bi, and their eutectics)

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, B.R.; Bauer, G.S. [comp.

    1996-06-01

    The International Workshop on the Technology and Thermal Hydraulics of Heavy Liquid Metals (Schruns Workshop) was organized to assess the R&D and technology problems associated with designing and building a heavy liquid metal target for a spallation neutron source. The European scientific community is completing a feasibility study for a future, accelerator-based, pulsed spallation neutron source that would deliver a beam power of 5 megawatts (MW) to a target. They have concluded that a liquid metal target is preferable to conventional solid targets for handling the extreme radiation environments, high heat loads, and pulsed power. Similarly, the ORNL has been funded by the DOE to design a high-power, pulsed spallation neutron source that would begin operation at about 1 MW but that could be upgraded to significantly higher powers in the future. Again, the most feasible target design appears to be a liquid metal target. Since the expertise needed to consider these problems resides in a number of disparate disciplines not normally covered by existing conferences, this workshop was organized to bring a small number of scientists and engineers together to assess the opportunities for building such a target. The objectives and goals of the Schruns Workshop were to: review and share existing information on the science and technology of heavy liquid metal systems. Evaluate the opportunities and limitations of materials compatibility, thermal hydraulics and heat transfer, chemical reactions, corrosion, radiation effects, liquid-gas mixtures, systems designs, and circuit components for a heavy liquid metal target. Establish the critical R & D and technology that is necessary to construct a liquid metal target. Explore opportunities for cooperative R & D among members of the international community that could expedite results, and share expertise and resources. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  17. [Application of off-line two dimensional reversed-phase liquid chromatography/supercritical fluid chromatography to the separation of the seeds of Trichosanthes kirilowii Maxim].

    Science.gov (United States)

    Yuan, Yun; Xin, Huaxia; Peng, Ziyue; Fu, Qing; Jin, Yu

    2017-07-08

    An off-line two dimensional reversed-phase liquid chromatography/supercritical fluid chromatography (2D RPLC/SFC) method was developed for the separation of the seeds of Trichosanthes kirilowii Maxim . ( T. kirilowii .). In the experiment, RPLC was used in the first dimension to analyze the samples. And 12 fractions (F 1 -F 12 ) were obtained according to the chromatographic peak collection mode, the fractions were re-analyzed in both RPLC and SFC modes. The results clearly showed that this 2D method had good orthogonality. The SFC was used as the second dimension. Ethanol- n -hexane (3:7, v/v) was used as a modifier in SFC. The modifier could provide appropriate elution power. When the sample load increased, it could also ensure the solubility of samples. The 2D RPLC/SFC method had obvious advantages for separating the compounds with similar properties, enriching and purifying the trace components. Finally, 150 peaks could be detected. The off-line 2D RPLC/SFC method will be further enlarged to a preparative level for preparation of compounds. The method can provide a practical reference for the purification of chemical constituents and material basis research of the seeds of T. kirilowii . in the future.

  18. First-line sunitinib versus pazopanib in metastatic renal cell carcinoma: Results from the International Metastatic Renal Cell Carcinoma Database Consortium

    DEFF Research Database (Denmark)

    Ruiz-Morales, Jose Manuel; Swierkowski, Marcin; Wells, J Connor

    2016-01-01

    BACKGROUND: Sunitinib (SU) and pazopanib (PZ) are standards of care for first-line treatment of metastatic renal cell carcinoma (mRCC). However, how the efficacy of these drugs translates into effectiveness on a population-based level is unknown. PATIENTS AND METHODS: We used the International mR...

  19. On the influence of the finite thickness of sources on the internal conversion lines observed in beta spectrometer

    International Nuclear Information System (INIS)

    Pecequilo, B.R.S.

    1976-01-01

    Electron lines are simulated by a Monte Carlo method in a digital computer in order to obtain an analytical formula to calculate the energy and the relative intensity of electron conversion lines when observed by beta spectrometry. The electrons come from the own thickness of the source. Computer program that simulate these lines is presented. In order to test the method, a direct comparison of the K-line of Hg-198 with the same line as simulated by the computer, is done [pt

  20. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  1. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification.

    Science.gov (United States)

    Niu, Xiaofeng; Xu, Qing; Zhang, Yi; Zhang, Yue; Yan, Yufeng; Liu, Tao

    2017-04-29

    Micro-nanoencapsulated phase change materials (M-NEPCMs) are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n -octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate):Tween80 (polyoxyethylene sorbitan monooleate):Span80 (sorbitan monooleate) = 0.1:0.6:0.3, which achieves the best stability of the n -octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  2. Replaceable liquid nitrogen piping

    International Nuclear Information System (INIS)

    Yasujima, Yasuo; Sato, Kiyoshi; Sato, Masataka; Hongo, Toshio

    1982-01-01

    This liquid nitrogen piping with total length of about 50 m was made and installed to supply the liquid nitrogen for heat insulating shield to three superconducting magnets for deflection and large super-conducting magnet for detection in the π-meson beam line used for high energy physics experiment in the National Laboratory for High Energy Physics. The points considered in the design and manufacture stages are reported. In order to minimize the consumption of liquid nitrogen during transport, vacuum heat insulation method was adopted. The construction period and cost were reduced by the standardization of the components, the improvement of welding works and the elimination of ineffective works. For simplifying the maintenance, spare parts are always prepared. The construction and the procedure of assembling of the liquid nitrogen piping are described. The piping is of double-walled construction, and its low temperature part was made of SUS 316L. The super-insulation by aluminum vacuum evaporation and active carbon were attached on the external surface of the internal pipe. The final leak test and the heating degassing were performed. The tests on evacuation, transport capacity and heat entry are reported. By making the internal pipe into smaller size, the piping may be more efficient. (Kako, I.)

  3. Joule-Heated Ceramic-Lined Melter to Vitrify Liquid Radioactive Wastes Containing Am241 Generated From MOX Fuel Fabrication in Russia

    International Nuclear Information System (INIS)

    Smith, E C; Bowan II, B W; Pegg, I; Jardine, L J

    2004-01-01

    The governments of the United Stated of America and the Russian Federation (RF) signed an Agreement September 1, 2000 to dispose of weapons plutonium that has been designated as no longer required for defense purposes. The Agreement declares that each country will disposition 34MT of excess weapons grade plutonium from their stockpiles. The preferred disposition technology is the fabrication of mixed oxide (MOx) fuel for use or burning in pressurized water reactors to destroy the plutonium. Implementation of this Agreement will require the conversion of plutonium metal to oxide and the fabrication of MOx fuel within the Russian Federation. The MOx fuel fabrication and metal to oxide conversion processes will generate solid and liquid radioactive wastes containing trace amounts of plutonium, neptunium, americium, and uranium requiring treatment, storage, and disposal. Unique to the Russian MOx fuel fabrication facility's flow-sheet is a liquid waste stream with high concentrations (∼1 g/l) of 241 Am and non radioactive silver. The silver is used to dissolve PuO 2 feed materials to the MOx fabrication facility. Technical solutions are needed to treat and solidify this liquid waste stream. Alternative treatment technologies for this liquid waste stream are being evaluated by a Russian engineering team. The technologies being evaluated include borosilicate and phosphate vitrification alternatives. The evaluations are being performed at a conceptual design level of detail under a Lawrence Livermore National Laboratory (LLNL) contract with the Russian organization TVEL using DOE NA-26 funding. As part of this contract, the RF team is evaluating the technical and economic feasibility of the US borosilicate glass vitrification technology based on a Duratek melter to solidify this waste stream into a form acceptable for storage and geologic disposal. The composition of the glass formed from treating the waste is dictated by the concentration of silver and americium it

  4. Simultaneous multi-mycotoxin determination in nutmeg by ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection.

    Science.gov (United States)

    Kong, Wei-Jun; Liu, Shu-Yu; Qiu, Feng; Xiao, Xiao-He; Yang, Mei-Hua

    2013-05-07

    A simple and sensitive analytical method based on ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with high performance liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection (USLE-IAC-HPLC-PCD-FLD) has been developed for simultaneous multi-mycotoxin determination of aflatoxins B1, B2, G1, G2 (AFB1, AFB2, AFG1, AFG2) and ochratoxin A (OTA) in 13 edible and medicinal nutmeg samples marketed in China. AFs and OTA were extracted from nutmeg samples by ultrasonication using a methanol : water (80 : 20, v/v) solution, followed by an IAC clean-up step. Different USL extraction conditions, pre-processing ways for nutmeg sample and clean-up columns for mycotoxins, as well as HPLC-PCD-FLD parameters (mobile phase, column temperature, elution procedure, excitation and emission wavelengths) were optimized. This method, which was appraised for analyzing nutmeg samples, showed satisfactory results with reference to limits of detection (LODs) (from 0.02 to 0.25 μg kg(-1)), limits of quantification (LOQs) (from 0.06 to 0.8 μg kg(-1)), linear ranges (up to 30 ng mL(-1) for AFB1, AFG1 and OTA and 9 ng mL(-1) for AFB2 and AFG2), intra- and inter-day variability (all application of developed method in nutmeg samples have elucidated that four samples were detected with contamination of AFs and one with OTA. AFB1 was the most frequently found mycotoxin in 30.8% of nutmeg samples at contamination levels of 0.73-16.31 μg kg(-1). At least two different mycotoxins were co-occurred in three samples, and three AFs were simultaneously detected in one sample.

  5. Off-line separation and determination of rare earth elements associated with chloroplast pigments of hyperaccumulator Dicranopteris dichotoma by normal-phase liquid chromatography and ICP-MS.

    Science.gov (United States)

    Wei, Z G; Hong, F S; Yin, M; Li, H X; Hu, F; Zhao, G W; Wong, J W C

    2004-10-01

    An off-line normal-phase liquid chromatography-ICP-MS method has been used for separation and determination of the rare earth elements (REE) associated with chloroplast pigments of Dicranopteris dichotoma. The stability of REE-bound pigments was tested, and almost no destruction of REE-bound pigments occurred during the so-called normal-phase liquid chromatography. The accumulated free REE ions on the microcrystalline cellulose column were cleaned by elution with 5 mmol L(-1) 2-ethylhexyl hydrogen 2-ethylhexylphosphonate (P507), to avoid exchange of these free ions with metals from the pigments. When these precautions were taken, the method was applied to the study of REE-bound pigments in D. dichotoma. ICP-MS results showed REE were present in chlorophylls and lutein, although REE concentrations in carotene and pheophytin were both below procedural blank levels. By careful analysis of the eluate fractions containing chlorophyll a it was found that REE-bound chlorophyll a in D. dichotoma was slightly enriched in the fractions with relatively short retention time. Results indicated that the retention time of REE-bound chlorophyll a might be slightly less than that of magnesium chlorophyll a, and REE-bound chlorophylls might be of relatively low polarity in comparison with magnesium bound chlorophylls. This phenomenon could be explained by the special double-decker sandwich-structure of REE-bound chlorophylls, as was reported by us and other authors. On the basis of these results we preferred to consider that REE can replace magnesium in chlorophyll a of D. dichotoma, and that the role of REE-bound chlorophylls in photosynthesis cannot be neglected. These data might be useful for understanding of both the properties of REE-bound pigments and the effect of REE on plant photosynthesis.

  6. In-line carbon nanofiber reinforced hollow fiber-mediated liquid phase microextraction using a 3D printed extraction platform as a front end to liquid chromatography for automatic sample preparation and analysis: A proof of concept study.

    Science.gov (United States)

    Worawit, Chanatda; Cocovi-Solberg, David J; Varanusupakul, Pakorn; Miró, Manuel

    2018-08-01

    A novel concept for automation of nanostructured hollow-fiber supported microextraction, combining the principles of liquid-phase microextraction (LPME) and sorbent microextraction synergically, using mesofluidic platforms is proposed herein for the first time, and demonstrated with the determination of acidic drugs (namely, ketoprofen, ibuprofen, diclofenac and naproxen) in urine as a proof-of-concept applicability. Dispersed carbon nanofibers (CNF) are immobilized in the pores of a single-stranded polypropylene hollow fiber (CNF@HF) membrane, which is thereafter accommodated in a stereolithographic 3D-printed extraction chamber without glued components for ease of assembly. The analytical method involves continuous-flow extraction of the acidic drugs from a flowing stream donor (pH 1.7) into an alkaline stagnant acceptor (20 mmol L -1 NaOH) containing 10% MeOH (v/v) across a dihexyl ether impregnated CNF@HF membrane. The flow setup features entire automation of the microextraction process including regeneration of the organic film and on-line injection of the analyte-laden acceptor phase after downstream neutralization into a liquid chromatograph (LC) for reversed-phase core-shell column-based separation. Using a 12-cm long CNF@HF and a sample volume of 6.4 mL, linear dynamic ranges of ketoprofen, naproxen, diclofenac and ibuprofen, taken as models of non-steroidal anti-inflammatory drugs, spanned from ca. 5-15 µg L -1 to 500 µg L -1 with enhancement factors of 43-97 (against a direct injection of 10 µL standards into LC), and limits of detection from 1.6 to 4.3 µg L -1 . Relative recoveries in real urine samples ranged from 97% to 105%, thus demonstrating the reliability of the automatic CNF@HF-LPME method for in-line matrix clean-up and determination of drugs in urine at therapeutically relevant concentrations. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Determination of the total concentration of highly protein-bound drugs in plasma by on-line dialysis and column liquid chromatography: application to non-steroidal anti-inflammatory drugs.

    NARCIS (Netherlands)

    Herraez-Hernandez, R.; van de Merbel, N.C.; Brinkman, U.A.T.

    1995-01-01

    The potential of on-line dialysis as a sample preparation procedure for compounds highly bound to plasma proteins is evaluated, using non-steroidal anti-inflammatory drugs as model compounds and column liquid chromatography as the separation technique. Different strategies to reduce the degree of

  8. Determination of the total concentration of highly protein-bound drugs in plasma by on-line dialysis and column liquid chromatography : application to non-steroidal anti-inflammatory drugs

    NARCIS (Netherlands)

    Herráez-Hernández, R; van de Merbel, N C; Brinkman, U A

    1995-01-01

    The potential of on-line dialysis as a sample preparation procedure for compounds highly bound to plasma proteins is evaluated, using non-steroidal anti-inflammatory drugs as model compounds and column liquid chromatography as the separation technique. Different strategies to reduce the degree of

  9. Changing Mental Representations Using Related Physical Models: The Effects of Analyzing Number Lines on Learner Internal Scale of Numerical Magnitude

    Science.gov (United States)

    Bengtson, Barbara J.

    2013-01-01

    Understanding the linear relationship of numbers is essential for doing practical and abstract mathematics throughout education and everyday life. There is evidence that number line activities increase learners' number sense, improving the linearity of mental number line representations (Siegler & Ramani, 2009). Mental representations of…

  10. The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Chen Ligang; Ding Lan; Jin Haiyan; Song Daqian; Zhang Huarong; Li Jiantao; Zhang Kun; Wang Yutang; Zhang Hanqi

    2007-01-01

    A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM 010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min -1 . The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g -1 . The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required

  11. Determination of phenols by flow injection and liquid chromatography with on-line quinine-sensitized photo-oxidation and quenched luminol chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Wei; Danielson, Neil D.

    2003-01-01

    An on-line quinine-sensitized photo-oxidation with quenched chemiluminescence (CL) detection method is developed for phenols using flow injection (FI) and liquid chromatography (LC). This detection method is based on the decrease of light emission from the luminol CL reaction due to the photo-oxidation of phenols that scavenge the photogenerated reactive oxygen species (e.g. singlet oxygen ( 1 O 2 ) and superoxide (O 2 · - )). On-line photo-oxidation is achieved using a coil photo-reactor made from fluoroethylene-propylene copolymer tubing (3048 mmx0.25 mm i.d.) coiled around a mercury UV lamp. A buffer of pH 7 and a concentration of 350 μM for quinine sulfate are determined optimum for the sensitized photo-oxidation. Using a carrier system flow rate of 60 μl/min, calibration curves taken by FI for 10 phenolic compounds in aqueous solutions showed this decreasing sensitivity order: 4-chlorophenol, phenol, 4-nitrophenol, 3-hydroxy-L-kynurenine, 2-nitrophenol, salicylate, 3-nitrophenol, catechol, 2,4-dinitrophenol, and 2,4-dichlorophenol. This detection method using two tandem coil photo-reactors is also applied for the LC separation of phenol, 4-nitrophenol and 4-chlorophenol on an octadecyl (C18) silica LC column using acetonitrile-H 2 O (40:60, v/v) as a mobile phase. The quenched CL detection limits (about 1 μM or 20 pmol) for phenol and 4-chlorophenol are comparable to those for UV detection at 254 nm. Some selectivity in the quenched CL detection is evident by no interference in the FI phenol response even when benzaldehyde and phenethanol concentrations are 8 and 15 times that of phenol

  12. Measurements of the osmotic pressure in liquid mixtures of 3He and 4He near the lambda line and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.

    1977-06-01

    Values of the concentration susceptibility near the lambda line and tricritical point in liquid mixtures of 3 He and 4 He have been calculated from measurements of osmotic pressure differences. Measurements were made by inducing a small 3 He mole fraction difference Δx between two chambers separated by a pressure transducer, and measuring the resulting osmotic pressure difference as a function of temperature. Osmotic equilibrium was established through a Vycor glass superleak, which for 3 He mole fraction x > 0.55 functions not only in the superfluid phase but in portions of the normal fluid region of the phase diagram as well. Measurements were made at four 3 He mole fractions, x = 0.59, x = 0.64, x = 0.68, and x = 0.70. In contrast with determinations from light scattering and vapor pressure measurements, the present measurements show a pronounced peak at the lambda transition for the two values of x less than the tricritical value (x/sub t/ = 0.675). The susceptibilities are consistent with α = 0 both above and below the lambda transition except at x = 0.64, where some combination of α and α' greater than zero seems to be preferred. (The result α = 0 corresponds to a logarithmic divergence.) It is possible that this positive value of α or α' represents the influence of tricritical effects. It should be emphasized that there is considerable ambiguity in our determination of α, with acceptable least-squares fits corresponding to values of α between 0.0 and 0.2 being found at both concentrations, both above and below T/sub lambda/. The results appear to be consistent with the results of other experiments away from the lambda line, and also to be consistent with a simple tricritical scaling relationship

  13. Determination of 18 veterinary antibiotics in environmental water using high-performance liquid chromatography-q-orbitrap combined with on-line solid-phase extraction.

    Science.gov (United States)

    Kim, Chansik; Ryu, Hong-Duck; Chung, Eu Gene; Kim, Yongseok

    2018-05-01

    The use of antibiotics and their occurrence in the environment have received significant attention in recent years owing to the generation of antibiotic-resistant bacteria. Antibiotic residues in water near livestock farming areas should be monitored to establish effective strategies for reducing the use of veterinary antibiotics. However, environmental water contamination resulting from veterinary antibiotics has not been studied extensively. In this work, we developed an analytical method for the simultaneous determination of multiple classes of veterinary antibiotic residues in environmental water using on-line solid-phase extraction (SPE)-high performance liquid chromatography (HPLC)-high resolution mass spectrometry (HRMS). Eighteen popular antibiotics (eight classes) were selected as target analytes based on veterinary antibiotics sales in South Korea in 2015. The developed method was validated by calibration-curve linearities, precisions, relative recoveries, and method detection limits (MDLs)/limits of quantification (LOQs) of the selected antibiotics, and applied to the analysis of environmental water samples (groundwater, river water, and wastewater-treatment-plant effluent). All calibration curves exhibited r 2  > 0.995 with MDLs ranging from 0.2 to 11.9 ng/L. Relative recoveries were between 50 and 150% with coefficients of variation below 20% for all analytes (spiked at 500 ng/L) in groundwater and river water samples. Relative standard deviations (RSDs) of standard-spiked samples were lower than 7% for all antibiotics. The on-line SPE system eliminates human-based SPE errors and affords excellent method reproducibility. Amoxicillin, ampicillin, clopidol, fenbendazole, flumequine, lincomycin, sulfadiazine, and trimethoprim were detected in environmental water samples in concentrations ranging from 1.26 to 127.49 ng/L. The developed method is a reliable analytical technique for the potential routine monitoring of veterinary antibiotics

  14. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Monitoring changes in anthocyanin and steroid alkaloid glycoside content in lines of transgenic potato plants using liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Stobiecki, Maciej; Matysiak-Kata, Iwona; Frański, Rafał; Skała, Jacek; Szopa, Jan

    2003-03-01

    Transgenic potato plants overexpressing and repressing enzymes of flavonoids biosynthesis were created and analyzed. The selected plants clearly showed the expected changes in anthocyanins synthesis level. Overexpression of a DNA encoding dihydroflavonol 4-reductase (DFR) in sense orientation resulted in an increase in tuber anthocyanins, a 4-fold increase in petunidin and pelargonidin derivatives. A significant decrease in anthocyanin level was observed when the plant was transformed with a corresponding antisense construct. The transformation of potato plants was also accompanied by significant changes in steroid alkaloid glycosides (SAG) level in transgenic potato tuber. The changes in SAGs content was not dependent on flavonoid composition in transgenic potato. However, in an extreme situation where the highest (DFR11) or the lowest (DFRa3) anthocyanin level was detected the positive correlation with steroid alkaloid content was clearly visible. It is suggested that the changes in SAGs content resulted from chromatin stressed upon transformation. A liquid chromatography/mass spectrometry (LC/MS) system with electrospray ionization was applied for profiling qualitative and quantitative changes of steroid alkaloid glycosides in tubers of twelve lines of transgenic potato plants. Except alpha-chaconine and alpha-solanine, in the extracts from dried tuber skin alpha-solamargine and alpha-solasonine, triglycosides of solasonine, were identified in minor amounts, triglycosides of solanidine dehydrodimers were also recognized.

  16. On-line coupling of size exclusion chromatography with mixed-mode liquid chromatography for comprehensive profiling of biopharmaceutical drug product.

    Science.gov (United States)

    He, Yan; Friese, Olga V; Schlittler, Michele R; Wang, Qian; Yang, Xun; Bass, Laura A; Jones, Michael T

    2012-11-02

    A methodology based on on-line coupling of size exclusion chromatography (SEC) with mixed-mode liquid chromatography (LC) has been developed. The method allows for simultaneous measurement of a wide range of components in biopharmaceutical drug products. These components include the active pharmaceutical ingredient (protein) and various kinds of excipients such as cations, anions, nonionic hydrophobic surfactant and hydrophilic sugars. Dual short SEC columns are used to separate small molecule excipients from large protein molecules. The separated protein is quantified using a UV detector at 280 nm. The isolated excipients are switched, online, to the Trinity P1 mixed-mode column for separation, and detected by an evaporative light scattering detector (ELSD). Using a stationary phase with 1.7 μm particles in SEC allows for the use of volatile buffers for both SEC and mix-mode separation. This facilitates the detection of different excipients by ELSD and provides potential for online characterization of the protein with mass spectrometry (MS). The method has been applied to quantitate protein and excipients in different biopharmaceutical drug products including monoclonal antibodies (mAb), antibody drug conjugates (ADC) and vaccines. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Metabolite profiling of a diverse collection of wheat lines using ultraperformance liquid chromatography coupled with time-of-flight mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Shawna B Matthews

    Full Text Available Genetic differences among major types of wheat are well characterized; however, little is known about how these distinctions affect the small molecule profile of the wheat seed. Ethanol/water (65% v/v extracts of seed from 45 wheat lines representing 3 genetically distinct classes, tetraploid durum (Triticum turgidum subspecies durum (DW and hexaploid hard and soft bread wheat (T. aestivum subspecies aestivum (BW were subjected to ultraperformance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC-TOF-MS. Discriminant analyses distinguished DW from BW with 100% accuracy due to differences in expression of nonpolar and polar ions, with differences attributed to sterol lipids/fatty acids and phospholipids/glycerolipids, respectively. Hard versus soft BW was distinguished with 100% accuracy by polar ions, with differences attributed to heterocyclic amines and polyketides versus phospholipid ions, respectively. This work provides a foundation for identification of metabolite profiles associated with desirable agronomic and human health traits and for assessing how environmental factors impact these characteristics.

  18. Analysis of phenolic compounds from different morphological parts of Helichrysum devium by liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection.

    Science.gov (United States)

    Gouveia, Sandra C; Castilho, Paula C

    2009-12-01

    A simple and rapid method has been used for the screening and identification of the main phenolic compounds from Helichrysum devium using high-performance liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection (LC-DAD/ESI-MS(n)). The total aerial parts and different morphological parts of the plant, namely leaves, flowers and stems, were analyzed separately. A total of 34 compounds present in the methanolic extract from Helichrysum devium were identified or tentatively characterized based on their UV and mass spectra and retention times. Three of these compounds were positively identified by comparison with reference standards. The phenolic compounds included derivatives of quinic acid, O-glycosylated flavonoids, a caffeic acid derivative and a protocatechuic acid derivative. The characteristic loss of 206 Da from malonylcaffeoyl quinic acid was used to confirm the malonyl linkage to the caffeoyl group. This contribution presents one of the first reports on the analysis of phenolic compounds from Helichrysum devium using LC-DAD/ESI-MS(n) and highlights the prominence of quinic acid derivatives as the main group of phenolic compounds present in these extracts. We also provide evidence that the methanolic extract from the flowers was significantly more complex when compared to that of other morphological parts. Copyright 2009 John Wiley & Sons, Ltd.

  19. Detection of radiation-induced hydrocarbons in irradiated fish and prawns by means of on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bogl, K.W.; Schreiberg, G.A.

    1997-01-01

    Radiation-induced hydrocarbons were analyzed in a fatty (halibut) and a lean fish (cod) as well as in a prawn species by on-line coupled liquid chromatography (LC) -gas chromatography (GC) combined with mass spectrometry. In irradiated halibut which is known to contain mainly saturated and monounsaturated fatty acids, all expected radiolytic alkanes, alkenes, and alkadienes could be detected. The yields of the C(n-1) and C(n-2:1) hydrocarbons were comparable to those found in irradiated lipids of terrestrial animals and plants. However, in cod and prawns which contain high levels of polyunsaturated fatty acids (PUFA), the C(n-1) hydrocarbons were found in concentrations which were up to 10 times higher whereas the C(n-2:1) products were again comparable to those of terrestrial animals and plants. The identification of radiation-induced hydrocarbons in fish lipids was achieved by transfer of the hydrocarbons from the LC column to the gas chromatographic column in fractions differing in their degree of unsaturation. For the first time, radiation-induced hydrocarbons with more than four double bonds generated from polyunsaturated fatty acids (20:4 omega 6 and 20:5 omega 3) could be identified

  20. Characterisation of organic compounds in aerosol particles from a finnish forest by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shimmo, Masahiko; Jaentti, Jaana; Hartonen, Kari; Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland); Aalto, Pasi; Kulmala, Markku [Division of Atmospheric Sciences, Department of Physical Sciences, University of Helsinki, P.O. Box 64, 00014, Helsinki (Finland)

    2004-04-01

    During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC-MS. A fraction volume as high as 840 {mu}L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified. (orig.)

  1. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification

    Directory of Open Access Journals (Sweden)

    Xiaofeng Niu

    2017-04-01

    Full Text Available Micro-nanoencapsulated phase change materials (M-NEPCMs are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate:Tween80 (polyoxyethylene sorbitan monooleate:Span80 (sorbitan monooleate = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  2. International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

    Science.gov (United States)

    Morton, Richard D.; Jurick, Matthew; Roman, Ruben; Adamson, Gary; Bui, Chinh T.; Laliberte, Yvon J.

    2011-01-01

    The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

  3. [Qualitative and quantitative evaluation of an internal medicine assistance line dedicated to the diagnosis and treatment of diseases for general practice].

    Science.gov (United States)

    Castillo, J-M; Agard, C; Artifoni, M; Brisseau, J-M; Connault, J; Durant, C; Espitia, O; Masseau, A; Neel, A; Perrin, F; Pistorius, M-A; Planchon, B; Ponge, T; Hamidou, M; Pottier, P

    2016-05-01

    Clinical reasoning and treatment challenges within the scope of general practice led to the development of an internal medicine assistance line provided by Nantes University Hospital. The primary outcome of this study was to describe callers' profile, their requests and answers provided. A prospective, cross-sectional, observational, descriptive study was undertaken. For each call were identified the calling physician, her/his specialty and work setting, the call's object and adequacy, the answer provided, the time needed to connect with the assistance line, the time devoted by the internal medicine physician to provide an answer to the request, and whether the assistance line prevented a visit to the emergency room. Each calling physician was then called back to obtain demographic and professional characteristics, and data relating to the call and to the assistance line. Sixty-three days were analyzed and 276 calls identified. The 237 identified calling physicians were mainly females (54%, n=93), with a mean age of 46 years, graduated from Nantes University (65%, n=86), practicing ambulatory general medicine (69%, n=164) in Loire-Atlantique department area (82%, n=176) for a mean duration of 15 years. Calls were mostly associated with diagnostic challenges (61%, n=166) concerning clinical issues (57%, n=155). A sole telephone advice was the main type of answer provided (56%, n=147) and a visit to the emergency room was prevented for 17% of calls. The assistance line activity is adequate with its missions and seems to facilitate patients' healthcare delivery advocating for the development of similar structures in other units. Improvements relating to the information, availability and physicians' training should be considered. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  4. Determination of plutonium in highly radioactive liquid waste by spectrophotometry using neodymium as an internal standard for safeguards analysis. Japan support program for agency safeguards (JASPAS) JC-19

    International Nuclear Information System (INIS)

    Taguchi, Shigeo; Surugaya, Naoki; Sato, Soichi; Kurosawa, Akira; Watahiki, Masaru; Hiyama, Toshiaki

    2006-06-01

    A spectrophotometric determination using neodymium as an internal standard was developed for safeguards verification analysis of plutonium in highly radioactive liquid waste which is produced by the reprocessing of spent nuclear fuel. The internal standard is used as a means to analyze plutonium and also to authenticate the instrument conditions. The method offers reduced sample preparation and analysis time compared to isotope dilution mass spectrometry. The sample was mixed with a known amount of internal standard. Subsequently, plutonium was quantitatively oxidized to Pu(VI) by the addition of Ce(IV) for spectrophotometry. Plutonium concentration was calculated from a relation between Nd(III)/Pu(VI) molar extinction coefficient ratio and their absorbance ratio. The relative expanded uncertainty of the repeated analysis (n=5) was 8.9% (coverage factor k=2) for a highly radioactive liquid waste sample (173 mg L -1 ). The determination limit was 6 mg L -1 (ten fold's the standard deviation). This method was validated through comparison experiments with isotope dilution mass spectrometry. The analytical results of plutonium in highly radioactive liquid waste using this method were agree well with values obtained using isotope dilution mass spectrometry. The proposed method can be applied to independent on-site safeguards analysis at the Tokai Reprocessing Plant. (author)

  5. Field Monitoring of Deformations and Internal Forces of Surrounding Rocks and Lining Structures in the Construction of the Gangkou Double-Arched Tunnel—A Case Study

    Directory of Open Access Journals (Sweden)

    Qixiang Yan

    2017-02-01

    Full Text Available Double-arched tunnel is a special and complex underground structure which needs to be monitored carefully during construction. Taking the Gangkou tunnel as the engineering background, this paper presents a case study of field monitoring of a representative double-arched tunnel. Typical cross sections were chosen in each class of surrounding rock masses in the tunnel area and different types of sensors were embedded in designed locations, and the deformations and forces of both surrounding rocks and lining structures were monitored systematically. The dynamic evolution as well as the spatial distribution characteristics of the monitoring data including the internal displacements of surrounding rocks and the contact pressures between surrounding rocks and primary linings, the axial forces in rock bolts and the internal forces in both steel arches and secondary linings were analyzed. The monitoring and analysis results show that the deformations and forces of both surrounding rocks and lining structures are directly related to the construction procedures, geological conditions and locations in the double-arched tunnel. According to the results, some reasonable suggestions were provided for the improvement of the tunnel construction. This study will provide useful reference and guidance for the design, construction and monitoring of similar engineering projects in future.

  6. Study and development of the laser induced breakdown spectroscopy (LIBS) for the realization of field measurements: application to analysis on-line of metals in liquids

    International Nuclear Information System (INIS)

    Rosado, J.C.D.

    2013-01-01

    Metal contamination of water is a major public health issue. Controls and treatments are more drastic and performed on them for human consumption. It is essential for this to possess reliable and sensitive analytical tools adapted to the existing regulations and flexible enough to use. The technique of 'Laser Induced Breakdown Spectroscopy' (LIBS), proven for the analysis of solids, including exo-terrestrial explorations, this very interesting advantages for liquids including, for example, are multi-character elementary and the possibility of in-situ measurements of water contamination by metals. A first part of this study thesis allowed to explore the potential (LIBS) for the analysis of dissolved metals or suspensions in water. Study has found an important effect related to the particle size in the analysis of suspensions. A second prong is to look at the effects of organic matrix represented by humic acid and those natural minerals represented by the bentonite and alumina particles. The matrix effect observed was corrected by normalization by internal standard. (author) [fr

  7. Automatic on-line detection system design research on internal defects of metal materials based on optical fiber F-P sensing technology

    Science.gov (United States)

    Xia, Liu; Shan, Ning; Chao, Ban; Caoshan, Wang

    2016-10-01

    Metal materials have been used in aerospace and other industrial fields widely because of its excellent characteristics, so its internal defects detection is very important. Ultrasound technology is used widely in the fields of nondestructive detection because of its excellent characteristic. But the conventional detection instrument for ultrasound, which has shortcomings such as low intelligent level and long development cycles, limits its development. In this paper, the theory of ultrasound detection is analyzed. A computational method of the defects distributional position is given. The non-contact type optical fiber F-P interference cavity structure is designed and the length of origin cavity is given. The real-time on-line ultrasound detecting experiment devices for internal defects of metal materials is established based on the optical fiber F-P sensing system. The virtual instrument of automation ultrasound detection internal defects is developed based on LabVIEW software and the experimental study is carried out. The results show that this system can be used in internal defect real-time on-line locating of engineering structures effectively. This system has higher measurement precision. Relative error is 6.7%. It can be met the requirement of engineering practice. The system is characterized by simple operation, easy realization. The software has a friendly interface, good expansibility, and high intelligent level.

  8. Molecularly imprinted sol-gel nanofibers based solid phase microextraction coupled on-line with high performance liquid chromatography for selective determination of acesulfame.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Karimi, Mohammad; Akbari-Adergani, Behrouz

    2015-03-01

    Sol-gel based molecularly imprinted polymer (MIP) nanofiber was successfully fabricated by electrospinning technique on the surface of a stainless steel bar. The manufactured tool was applied for on-line selective solid phase microextraction (SPME) and determination of acesulfame (ACF) as an artificial sweetener with high performance liquid chromatography (HPLC). The selective ability of method for the extraction of ACF was investigated in the presence of some selected sweeteners such as saccharine (SCH), aspartame (ASP) and caffeine (CAF). Electrospinning of MIP sol-gel solution on the stainless steel bar provided an unbreakable sorbent with high thermal, mechanical, and chemical stability. Moreover, application of the MIP-SPME tool revealed a unique approach for the selective microextraction of the analyte in beverage samples. In this work, 3-(triethoxysilyl)-propylamine (TMSPA) was chosen as a precursor due to its ability to imprint the analyte by hydrogen bonding, Van der Walls, and dipole-dipole interactions. Nylon 6 was also added as a backbone and support for the precursor in which sol could greatly growth during the sol-gel process and makes the solution electrospinable. Various effective parameters in the extraction efficiency of the MIP-SPME tool such as loading time, flow rate, desorption time, selectivity, and the sample volume were evaluated. The linearity for the ACF in beverage sample was in the range of 0.78-100.5 ng mL(-1). Limit of detection (LOD) and quantification (LOQ) were 0.23 and 0.78 ng mL(-1) respectively. The RSD values (n=5) were all below 3.5%at the 20 ng mL(-1) level. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. High-Throughput Proteomics Using High Efficiency Multiple-Capillary Liquid Chromatography With On-Line High-Performance ESI FTICR Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yufeng (BATTELLE (PACIFIC NW LAB)); Tolic, Nikola (BATTELLE (PACIFIC NW LAB)); Zhao, Rui (ASSOC WESTERN UNIVERSITY); Pasa Tolic, Ljiljana (BATTELLE (PACIFIC NW LAB)); Li, Lingjun (Illinois Univ Of-Urbana/Champa); Berger, Scott J.(ASSOC WESTERN UNIVERSITY); Harkewicz, Richard (BATTELLE (PACIFIC NW LAB)); Anderson, Gordon A.(BATTELLE (PACIFIC NW LAB)); Belov, Mikhail E.(BATTELLE (PACIFIC NW LAB)); Smith, Richard D.(BATTELLE (PACIFIC NW LAB))

    2000-12-01

    We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system was operated at the pressure of 10,000 psi using commercial LC pumps to deliver the mobile phase and newly developed passive feedback valves to switch the mobile phase flow and introduce samples. The multiple-capillary LC system was composed of several serially connected dual-capillary column devices. The dual-capillary column approach was designed to eliminate the time delay for regeneration (or equilibrium) of the capillary column after its use under the mobile phase gradient condition (i.e. one capillary column was used in separation and the other was washed using mobile phase A). The serially connected dual-capillary columns and ESI sources were operated independently, and could be used for either''backup'' operation or with other mass spectrometer(s). This high-efficiency multiple-capillary LC system uses switching valves for all operations and is highly amenable to automation. The separations efficiency of dual-capillary column device, optimal capillary dimensions (column length and packed particle size), suitable mobile phases for electrospray, and the capillary re-generation were investigated. A high magnetic field (11.5 tesla) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system through an electrospray ionization source. The capillary LC provided a peak capacity of {approx}600, and the 2-D capillary LC-FTICR provided a combined resolving power of > 6 x 10 7 polypeptide isotopic distributions. For yeast cellular tryptic digests, > 100,000 polypeptides were typically detected, and {approx}1,000 proteins can be characterized in a single run.

  10. An automatic on-line 2,2-diphenyl-1-picrylhydrazyl-high performance liquid chromatography method for high-throughput screening of antioxidants from natural products.

    Science.gov (United States)

    Lu, Yanzhen; Wu, Nan; Fang, Yingtong; Shaheen, Nusrat; Wei, Yun

    2017-10-27

    Many natural products are rich in antioxidants which play an important role in preventing or postponing a variety of diseases, such as cardiovascular and inflammatory disease, diabetes as well as breast cancer. In this paper, an automatic on-line 2,2-diphenyl-1-picrylhydrazyl-high performance liquid chromatography (DPPH-HPLC) method was established for antioxidants screening with nine standards including organic acids (4-hydroxyphenylacetic acid, p-coumaric acid, ferulic acid, and benzoic acid), alkaloids (coptisine and berberine), and flavonoids (quercitrin, astragalin, and quercetin). The optimal concentration of DPPH was determined, and six potential antioxidants including 4-hydroxyphenylacetic acid, p-coumaric acid, ferulic acid, quercitrin, astragalin, and quercetin, and three non-antioxidants including benzoic acid, coptisine, and berberine, were successfully screened out and validated by conventional DPPH radical scavenging activity assay. The established method has been applied to the crude samples of Saccharum officinarum rinds, Coptis chinensis powders, and Malus pumila leaves, consecutively. Two potential antioxidant compounds from Saccharum officinarum rinds and five potential antioxidant compounds from Malus pumila eaves were rapidly screened out. Then these seven potential antioxidants were purified and identified as p-coumaric acid, ferulic acid, phloridzin, isoquercitrin, quercetin-3-xyloside, quercetin-3-arabinoside, and quercetin-3-rhamnoside using countercurrent chromatography combined with mass spectrometry and their antioxidant activities were further evaluated by conventional DPPH radical scavenging assay. The activity result was in accordance with that of the established method. This established method is cheap and automatic, and could be used as an efficient tool for high-throughput antioxidant screening from various complex natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  12. Line Laser and Triple Laser Quantification of the Difference in International Roughness Index between Textured and Non-Textured Strips

    Science.gov (United States)

    2017-07-01

    Practitioners have often wondered whether, during ride measurement with inertial devices, the motion of the laser through pavement texture introduces non representative values of international roughness index (IRI), particularly in certain textures. ...

  13. Il sistema monetario internazionale negli anni settanta: regime dei tassi di cambio e creazione di liquidità. (Liquidity creation and risk in the international monetary system

    Directory of Open Access Journals (Sweden)

    L. DINI

    2013-12-01

    Full Text Available L' articolo esamina il funzionamento del sistema finanziario attuale, segnalando la sua funzione più importante , vale a dire l'offerta di liquidità e il suo impatto sulla vasta gamma di variabili finanziarie internazionali. Liquidità e rischio sono concetti strettamente correlati. Come Keynes e Hicks hanno insegnato , una definizione significativa di liquidità non può essere data senza fare riferimento al rischio. L'autore fornisce alcune considerazioni per aiutare a far luce sulle azioni politiche che potrebbero essere necessarie per mitigare i problemi e le difficoltà connesse con l'attuale impostazione monetaria internazionale .The article looks at how the present financial system works, signalling out its most crucial function, namely the provision of liquidity and its impact on the broad spectrum of international financial variables. Liquidity and risk are closely interrelated concepts. As Keynes and Hicks taught, a meaningful definition of liquidity cannot be given without reference to risk itself. The author provides some considerations to help shed light on the policy actions that may be required to mitigate the problems and difficulties associated with the current international monetary setting. JEL: G15, F30, E42

  14. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  15. Proposed amendment to presidential permit PP-63 and associated modifications to 500 kV international transmission line, Forbes, Minnesota to Manitoba, Canada

    International Nuclear Information System (INIS)

    1992-10-01

    This Addendum to the Final Environmental Assessment for the Proposed Amendment to Presidential Permit PP-63 and Associated Modifications to 500 kV International Transmission Line: Forbes, Minnesota to Manitoba, Canada (DOE/EA-587) addresses Northern States Power Company's (NSP) proposed expansion of the Forbes Substation. The applicant has requested that the expansion take place on the west side of the substation, within the existing property line, instead of on the north side as originally proposed. All of the proposed construction would take place on property already owned by NSP. DOE has reviewed the environmental impacts associated with this minor modification and has determined that the conclusions reached in the environmental assessment and Finding of No Significant Impact prepared in connection with NSP's original amendment request remain valid

  16. The prothrombin time/international normalised ratio (PT/INR) line: derivation of local INR with commercial thromboplastins and coagulometers – two independent studies

    DEFF Research Database (Denmark)

    Poller, Leon; Ibrahim, S.; Keown, M.

    2011-01-01

    reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5......Background: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP). Methods...... thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations. Results: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human...

  17. Simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero by on-line postcolumn derivation fluorescence detection and ultraviolet detection coupled two-dimensional high-performance liquid chromatography.

    Science.gov (United States)

    Cheng, Cheanyeh; Wu, Shing-Chen

    2011-05-20

    An innovative two-dimensional high-performance liquid chromatography system was developed for the simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero. A C8 reversed-phase chromatographic column with ultraviolet detection was used as the first dimension for the determination of aspartame, and a ligand-exchange chromatographic column with on-line postcolumn derivation fluorescence detection was employed as the second dimension for the analysis of amino acid enantiomers. The fluorimetric derivative reagent of amino acid enantiomers was o-phthaldialdehyde. The hydrolysis of aspartame in Coca-Cola Zero was induced by electric-heating or microwave heating. Aspartame was quantified by the matrix matched external standard calibration curve with a linear concentration range of 0-50 μg mL(-1) (r(2)=0.9984). The limit of detection (LOD) and the limit of quantification (LOQ) were 1.3 μg mL(-1) and 4.3 μg mL(-1), respectively. The amino acid enantiomers was analyzed by the matrix matched internal standard calibration method (D-leucine as the internal standard) with a linear concentration range of 0-10 μg mL(-1) (r(2)=0.9988-0.9997). The LODs and LOQs for L- and D-aspartic acid and L- and D-phenylalanine were 0.16-0.17 μg mL(-1) and 0.52-0.55 μg mL(-1), respectively, that was 12-13 times more sensitive than ultraviolet detection. The overall analysis accuracy for aspartame and amino acid enantiomers was 90.2-99.2% and 90.4-96.2%, respectively. The overall analysis precision for aspartame and amino acid enantiomers was 0.1-1.7% and 0.5-6.7%, respectively. Generally, the extent of aspartame hydrolysis increases with the increase of electro-thermal temperature, microwave power, and the duration of hydrolysis time. D-aspartic acid and D-phenylalanine can be observed with the electro-thermal racemization at the hydrolysis temperature 120°C for 1 day and only D-aspartic acid can be observed at the hydrolysis temperature 90°C for 2 and 3 days. For

  18. Analysis of electrophoretic soil humic acids fractions by reversed-phase high performance liquid chromatography with on-line absorbance and fluorescence detection.

    Science.gov (United States)

    Trubetskoj, Oleg A; Richard, Claire; Guyot, Ghislain; Voyard, Guillaume; Trubetskaya, Olga E

    2012-06-22

    A combination of reversed-phase high performance liquid chromatography (RP HPLC) with on-line absorbance and fluorescence detection was used for analysis of chernozem soil humic acids (HAs) and their fractions A, B and C+D with different electrophoretic mobility (EM) and molecular size (MS). Samples were injected onto the column at the identical volume and absorbance. All chromatograms exhibit the resolution of seven peaks. The estimation of relative recovery of HAs and fractions from the reverse-phase column has been done. High MS fraction A, which possesses the low EM, is essentially more hydrophobic (73% of the fraction amount remained adsorbed on the column) and aliphatic than medium MS and EM fraction B (33% of the fraction amount remained adsorbed on the column). The most hydrophilic and aromatic properties belong to low MS fraction C+D, which possess the highest EM and practically was not adsorbed on the column. The hydrophobicity of the bulk HAs lies within the range of fractions hydrophobicity. The absorption spectra of bulk HAs, electrophoretic fractions A, B, C+D and corresponding RP HPLC peaks were featureless but had differences in the values of absorbance ratio at 300 and 400 nm (A3/A4). For fractions A and B this ratio gradually decreased from peak 1 to 7 (from 3.05 to 2.80 and 3.00 to 2.40, respectively). This trend was less pronounced in HAs and practically absent in fraction C+D, where ratio A3/A4 varied within a small range. The strong relationship between fluorescence properties, EM, MS, polarity and aliphaticity/aromaticity of HAs fractions was found. Humic and protein-like fluorescence had different polarity nature. The protein-like fluorescence is located in humic material which irreversibly adsorbed on the reverse-phase column and not subjected to RP HPLC characterization. The humic-like fluorescence at Ex/Em 270/450 nm is mostly located in the hydrophilic peak of low MS fraction C+D. Taking into account that high MS fraction A consisted

  19. On-line solid phase extraction-liquid chromatography-tandem mass spectrometry for insect repellent residue analysis in surface waters using atmospheric pressure photoionization.

    Science.gov (United States)

    Molins-Delgado, Daniel; García-Sillero, Daniel; Díaz-Cruz, M Silvia; Barceló, Damià

    2018-04-06

    Insect repellents (IRs) are a group of organic chemicals whose function is to prevent the ability of insects of landing in a surface. These compounds have been found in the environment and may pose a risk to non-target organisms. In this study, an on-line solid phase extraction - high performance liquid chromatography-tandem mass spectrometry multiresidue method was developed using an atmospheric photoionization source (SPE-HPLC-(APPI)-MS/MS). The use of the APPI as an alternative ionization technique to electrospray (ESI) and atmospheric pressure chemical ionization (APCI) allowed expanding the range of analytical techniques suitable for the analysis of IRs, so far relied in gas chromatography. High sensitivity and precision was reached with method limits of quantification between 0.2 and 4.6 ng l -1 and interday and intraday precision equal or below 15%. The validated method was applied to the study of surface water samples from three European river basins with different flow regime (Adige River in Italy, Sava River in the Balkans, and Evrotas River in Greece). The results showed that two IRs (DEET and Bayrepel) were ubiquitous in the Sava and Evrotas basins, reaching concentrations as high as 105 μg l -1 of Bayrepel in the Sava River, and 5 μg l -1 of DEET in the Evrotas River. Densely populated areas and effluent waste waters are pointed out as the responsible for this pollution. In the alpine river Adige, only three samples showed low levels of IRs (6.01-37.8 ng l -1 ). The concentrations measured were used to perform an environmental risk assessment based on the hazard quotients (HQs) estimation approach by using the chronic and acute eco-toxicity data available. The results revealed that despite the high frequency and eventually high concentrations of these IRs determined in the three basins, only few sites were at risk, with 1 < HQs < 3.3. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  20. Proceedings of the international seminar on chemistry and process engineering for high-level liquid waste solidification

    International Nuclear Information System (INIS)

    Odoj, R.; Merz, E.

    1981-06-01

    The proceedings record a very distinct phase of the chemistry and process engineering for high-level liquid waste solidification in the past years. The main purpose is to provide solutions which guarantee sufficient safe and economically acceptable measure causing no adverse consequence to man and his environment. (DG)

  1. Constitutively internalized dopamine transporter is targeted to late endosomes and lysosomal degradation in heterologous cell lines and dopaminergic neurons

    DEFF Research Database (Denmark)

    Eriksen, Jacob; Madsen, Kenneth; Vægter, Christian Bjerggaard

    and amphetamine, a substrate of the DAT. In antibody feeding experiments we observed that Tac-DAT was constitutively internalized faster than Tac alone and using an ELISA based assay we could quantify time-dependent intracellular accumulation of the transporter. Incubation with inhibitors of lysosomal degradation...... (leupeptin, chloroquine, or ammonium chloride) increased the amount of transporter accumulated intracellularly over time, suggesting that constitutively endocytosed transporter was targeted to lysosomal degradation. This was further supported by expression of Tac-DAT in the immortalized dopaminergic cell...... dopaminergic neurons and visualized the DAT directly in the neurons using the fluorescent cocaine analog JHC 1-064. These data showed pronounced colocalization upon constitutive internalization with Lysotracker, a late endosomal/lysosomal marker; however only little co-lolization was observed with Alexa488...

  2. Hydrophilic interaction liquid chromatography of anthranilic acid-labelled oligosaccharides with a 4-aminobenzoic acid ethyl ester-labelled dextran hydrolysate internal standard.

    Science.gov (United States)

    Neville, David C A; Alonzi, Dominic S; Butters, Terry D

    2012-04-13

    Hydrophilic interaction liquid chromatography (HILIC) of fluorescently labelled oligosaccharides is used in many laboratories to analyse complex oligosaccharide mixtures. Separations are routinely performed using a TSK gel-Amide 80 HPLC column, and retention times of different oligosaccharide species are converted to glucose unit (GU) values that are determined with reference to an external standard. However, if retention times were to be compared with an internal standard, consistent and more accurate GU values would be obtained. We present a method to perform internal standard-calibrated HILIC of fluorescently labelled oligosaccharides. The method relies on co-injection of 4-aminobenzoic acid ethyl ester (4-ABEE)-labelled internal standard and detection by UV absorption, with 2-AA (2-aminobenzoic acid)-labelled oligosaccharides. 4-ABEE is a UV chromophore and a fluorophore, but there is no overlap of the fluorescent spectrum of 4-ABEE with the commonly used fluorescent reagents. The dual nature of 4-ABEE allows for accurate calculation of the delay between UV and fluorescent signals when determining the GU values of individual oligosaccharides. The GU values obtained are inherently more accurate as slight differences in gradients that can influence retention are negated by use of an internal standard. Therefore, this paper provides the first method for determination of HPLC-derived GU values of fluorescently labelled oligosaccharides using an internal calibrant. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Properties of internalization factors contributing to the uptake of extracellular DNA into tumor-initiating stem cells of mouse Krebs-2 cell line.

    Science.gov (United States)

    Dolgova, Evgeniya V; Potter, Ekaterina A; Proskurina, Anastasiya S; Minkevich, Alexandra M; Chernych, Elena R; Ostanin, Alexandr A; Efremov, Yaroslav R; Bayborodin, Sergey I; Nikolin, Valeriy P; Popova, Nelly A; Kolchanov, Nikolay A; Bogachev, Sergey S

    2016-05-25

    Previously, we demonstrated that poorly differentiated cells of various origins, including tumor-initiating stem cells present in the ascites form of mouse cancer cell line Krebs-2, are capable of naturally internalizing both linear double-stranded DNA and circular plasmid DNA. The method of co-incubating Krebs-2 cells with extracellular plasmid DNA (pUC19) or TAMRA-5'-dUTP-labeled polymerase chain reaction (PCR) product was used. It was found that internalized plasmid DNA isolated from Krebs-2 can be transformed into competent Escherichia coli cells. Thus, the internalization processes taking place in the Krebs-2 cell subpopulation have been analyzed and compared, as assayed by E. coli colony formation assay (plasmid DNA) and cytofluorescence (TAMRA-DNA). We showed that extracellular DNA both in the form of plasmid DNA and a PCR product is internalized by the same subpopulation of Krebs-2 cells. We found that the saturation threshold for Krebs-2 ascites cells is 0.5 μg DNA/10(6) cells. Supercoiled plasmid DNA, human high-molecular weight DNA, and 500 bp PCR fragments are internalized into the Krebs-2 tumor-initiating stem cells via distinct, non-competing internalization pathways. Under our experimental conditions, each cell may harbor 340-2600 copies of intact plasmid material, or up to 3.097 ± 0.044×10(6) plasmid copies (intact or not), as detected by quantitative PCR. The internalization dynamics of extracellular DNA, copy number of the plasmids taken up by the cells, and competition between different types of double-stranded DNA upon internalization into tumor-initiating stem cells of mouse ascites Krebs-2 have been comprehensively analyzed. Investigation of the extracellular DNA internalization into tumor-initiating stem cells is an important part of understanding their properties and possible destruction mechanisms. For example, a TAMRA-labeled DNA probe may serve as an instrument to develop a target for the therapy of cancer, aiming at elimination of

  4. Progress in liquid metal fast reactor technology. Proceedings of the 28th meeting of the International Working Group on Fast Reactors

    International Nuclear Information System (INIS)

    1996-04-01

    The key objectives and activities of Member State liquid metal fast reactor (LMFR) programmes are: Demonstration of effective designs; demonstration of system safety; demonstration of economic competitiveness with other power generation systems. The International Working Group on Fast Reactors (IWGFR) at its 1995 meeting observed that while some countries (as a result of static or falling power demand) are reducing the research and development programmes or delaying the commercial deployment of fast reactors, other countries are planning to introduce these reactors and are embarking on their own development programmes. In these circumstances the international exchange of information and experience is of increasing importance. These proceedings contain updated information from long standing members of the IWGFR and new information on the status of LMFR research and development from new members of the Group: Brazil, China, Republic of Kazakhstan and the Republic of Korea. Refs, figs, tabs

  5. Progress in liquid metal fast reactor technology. Proceedings of the 28th meeting of the International Working Group on Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The key objectives and activities of Member State liquid metal fast reactor (LMFR) programmes are: Demonstration of effective designs; demonstration of system safety; demonstration of economic competitiveness with other power generation systems. The International Working Group on Fast Reactors (IWGFR) at its 1995 meeting observed that while some countries (as a result of static or falling power demand) are reducing the research and development programmes or delaying the commercial deployment of fast reactors, other countries are planning to introduce these reactors and are embarking on their own development programmes. In these circumstances the international exchange of information and experience is of increasing importance. These proceedings contain updated information from long standing members of the IWGFR and new information on the status of LMFR research and development from new members of the Group: Brazil, China, Republic of Kazakhstan and the Republic of Korea. Refs, figs, tabs.

  6. Vibration characteristics of functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports

    Science.gov (United States)

    Zhong, Rui; Wang, Qingshan; Tang, Jinyuan; Shuai, Cijun; Liang, Qian

    2018-02-01

    This paper presents the first known vibration characteristics of moderately thick functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports on the basis of the firstorder shear deformation theory. Different distributions of single walled carbon nanotubes (SWCNTs) along the thickness are considered. Uniform and other three kinds of functionally graded distributions of carbon nanotubes along the thickness direction of plates are studied. The solutions carried out using an enhanced Ritz method mainly include the following three points: Firstly, create the Lagrange energy function by the energy principle; Secondly, as the main innovation point, the modified Fourier series are chosen as the basic functions of the admissible functions of the plates to eliminate all the relevant discontinuities of the displacements and their derivatives at the edges; Lastly, solve the natural frequencies as well as the associated mode shapes by means of the Ritz-variational energy method. In this study, the influences of the volume fraction of CNTs, distribution type of CNTs, boundary restrain parameters, location of the internal line supports, foundation coefficients on the natural frequencies and mode shapes of the FG-CNT reinforced composite rectangular plates are presented.

  7. Nerves of steel: Canadians devised formula for international oil ventures behind enemy lines in the Cold War

    International Nuclear Information System (INIS)

    Jaremko, G.

    2002-01-01

    The Canadian formula for international success in oil, natural gas and associated services and equipment is described as a blend of stamina in extreme natural environments, an open mind, a sharp eye for technical opportunity, technical creativity, a sharp eye for fitting into foreign communities, and willingness to chart an independent course through global political conflict. By way of background, little known early western ventures into the then-touchiest international arena, the Soviet Union, are described. >From these early ventures in the 1970s resulted some pioneering ideas which, with Canadian refinements, became the cornerstones of today's oilfield technology: mud motors to drive bits with speed and precision, and SAGD or steam-assisted gravity drainage to tap the oil sands. It is well to remember that the industrial intelligence that gave us these fundamental tools was gathered at a time when it was common practice to disparage Russian industry for its shortcomings and inefficiency. Other examples cited are Nexen Inc.,'s successful exploitation of the Masila Block which has been producing an average of 118,300 barrels per day since 1993, which yielded $636 million in corporate cash flow in 2001. Nexen's 'Yemenization' program achieved 65 per cent employment of local hires and set an 80 per cent target for 2009, with scholarships and technology transfer plans serving the goal. This example of attention to community benefits such as employment, civic and health services, goes far towards making up for the Canadian drawback of small size by global industry standards. The independent streak in Canadian international oil and gas enterprise also continues to show most clearly at Talisman Energy, with its globally controversial role in Sudan. Despite continuous wrangling with missionary groups and advocates of U.S. sanctions against Sudan, Talisman Energy was able to persuade the government to make public the government's share in proceeds from the oil

  8. Nerves of steel: Canadians devised formula for international oil ventures behind enemy lines in the Cold War

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, G.

    2002-06-03

    The Canadian formula for international success in oil, natural gas and associated services and equipment is described as a blend of stamina in extreme natural environments, an open mind, a sharp eye for technical opportunity, technical creativity, a sharp eye for fitting into foreign communities, and willingness to chart an independent course through global political conflict. By way of background, little known early western ventures into the then-touchiest international arena, the Soviet Union, are described. >From these early ventures in the 1970s resulted some pioneering ideas which, with Canadian refinements, became the cornerstones of today's oilfield technology: mud motors to drive bits with speed and precision, and SAGD or steam-assisted gravity drainage to tap the oil sands. It is well to remember that the industrial intelligence that gave us these fundamental tools was gathered at a time when it was common practice to disparage Russian industry for its shortcomings and inefficiency. Other examples cited are Nexen Inc.,'s successful exploitation of the Masila Block which has been producing an average of 118,300 barrels per day since 1993, which yielded $636 million in corporate cash flow in 2001. Nexen's 'Yemenization' program achieved 65 per cent employment of local hires and set an 80 per cent target for 2009, with scholarships and technology transfer plans serving the goal. This example of attention to community benefits such as employment, civic and health services, goes far towards making up for the Canadian drawback of small size by global industry standards. The independent streak in Canadian international oil and gas enterprise also continues to show most clearly at Talisman Energy, with its globally controversial role in Sudan. Despite continuous wrangling with missionary groups and advocates of U.S. sanctions against Sudan, Talisman Energy was able to persuade the government to make public the government's share in

  9. Advanced treatment of biologically pretreated coal chemical industry wastewater using the catalytic ozonation process combined with a gas-liquid-solid internal circulating fluidized bed reactor.

    Science.gov (United States)

    Li, Zhipeng; Liu, Feng; You, Hong; Ding, Yi; Yao, Jie; Jin, Chao

    2018-04-01

    This paper investigated the performance of the combined system of catalytic ozonation and the gas-liquid-solid internal circulating fluidized bed reactor for the advanced treatment of biologically pretreated coal chemical industry wastewater (CCIW). The results indicated that with ozonation alone for 60min, the removal efficiency of chemical oxygen demand (COD) could reach 34%. The introduction of activated carbon, pumice, γ-Al 2 O 3 carriers improved the removal performance of COD, and the removal efficiency was increased by 8.6%, 4.2%, 2%, respectively. Supported with Mn, the catalytic performance of activated carbon and γ-Al 2 O 3 were improved significantly with COD removal efficiencies of 46.5% and 41.3%, respectively; however, the promotion effect of pumice supported with Mn was insignificant. Activated carbon supported with Mn had the best catalytic performance. The catalytic ozonation combined system of MnO X /activated carbon could keep ozone concentration at a lower level in the liquid phase, and promote the transfer of ozone from the gas phase to the liquid phase to improve ozonation efficiency.

  10. Quantification of pramipexole in human plasma by liquid chromatography tandem mass spectrometry using tamsulosin as internal standard.

    Science.gov (United States)

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam; Shrivastava, Wishu; Mudigonda, Koteshwara; Maurya, Santosh; Ajjala, Devender

    2007-11-01

    A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. Copyright (c) 2007 John Wiley & Sons, Ltd.

  11. Investigation of the design of a metal-lined fully wrapped composite vessel under high internal pressure

    Science.gov (United States)

    Kalaycıoğlu, Barış; Husnu Dirikolu, M.

    2010-09-01

    In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.

  12. Experimental investigation of temperature rise in bone drilling with cooling: A comparison between modes of without cooling, internal gas cooling, and external liquid cooling.

    Science.gov (United States)

    Shakouri, Ehsan; Haghighi Hassanalideh, Hossein; Gholampour, Seifollah

    2018-01-01

    Bone fracture occurs due to accident, aging, and disease. For the treatment of bone fractures, it is essential that the bones are kept fixed in the right place. In complex fractures, internal fixation or external methods are used to fix the fracture position. In order to immobilize the fracture position and connect the holder equipment to it, bone drilling is required. During the drilling of the bone, the required forces to chip formation could cause an increase in the temperature. If the resulting temperature increases to 47 °C, it causes thermal necrosis of the bone. Thermal necrosis decreases bone strength in the hole and, subsequently, due to incomplete immobilization of bone, fracture repair is not performed correctly. In this study, attempts have been made to compare local temperature increases in different processes of bone drilling. This comparison has been done between drilling without cooling, drilling with gas cooling, and liquid cooling on bovine femur. Drilling tests with gas coolant using direct injection of CO 2 and N 2 gases were carried out by internal coolant drill bit. The results showed that with the use of gas coolant, the elevation of temperature has limited to 6 °C and the thermal necrosis is prevented. Maximum temperature rise reached in drilling without cooling was 56 °C, using gas and liquid coolant, a maximum temperature elevation of 43 °C and 42 °C have been obtained, respectively. This resulted in decreased possibility of thermal necrosis of bone in drilling with gas and liquid cooling. However, the results showed that the values obtained with the drilling method with direct gas cooling are independent of the rotational speed of drill.

  13. International

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    This rubric reports on 10 short notes about international economical facts about nuclear power: Electricite de France (EdF) and its assistance and management contracts with Eastern Europe countries (Poland, Hungary, Bulgaria); Transnuclear Inc. company (a 100% Cogema daughter company) acquired the US Vectra Technologies company; the construction of the Khumo nuclear power plant in Northern Korea plays in favour of the reconciliation between Northern and Southern Korea; the delivery of two VVER 1000 Russian reactors to China; the enforcement of the cooperation agreement between Euratom and Argentina; Japan requested for the financing of a Russian fast breeder reactor; Russia has planned to sell a floating barge-type nuclear power plant to Indonesia; the control of the Swedish reactor vessels of Sydkraft AB company committed to Tractebel (Belgium); the renewal of the nuclear cooperation agreement between Swiss and USA; the call for bids from the Turkish TEAS electric power company for the building of the Akkuyu nuclear power plant answered by three candidates: Atomic Energy of Canada Limited (AECL), Westinghouse (US) and the French-German NPI company. (J.S.)

  14. Liquids and liquid mixtures

    CERN Document Server

    Rowlinson, J S; Baldwin, J E; Buckingham, A D; Danishefsky, S

    2013-01-01

    Liquids and Liquid Mixtures, Third Edition explores the equilibrium properties of liquids and liquid mixtures and relates them to the properties of the constituent molecules using the methods of statistical thermodynamics. Topics covered include the critical state, fluid mixtures at high pressures, and the statistical thermodynamics of fluids and mixtures. This book consists of eight chapters and begins with an overview of the liquid state and the thermodynamic properties of liquids and liquid mixtures, including vapor pressure and heat capacities. The discussion then turns to the thermodynami

  15. Determination of the oxidative stress biomarker urinary 8-hydroxy-2'-deoxyguanosine by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kataoka, Hiroyuki; Mizuno, Keisuke; Oda, Eri; Saito, Akihiro

    2016-04-15

    A simple and sensitive method for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a marker of oxidative DNA damage in human urine, was developed using automated on-line in-tube solid-phase microextraction (SPME) coupled with stable isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). Creatinine was also analyzed simultaneously to normalize urine volume by the in-tube SPME LC-MS/MS method, and 8-OHdG and creatinine were separated within 3 min using a Zorbax Eclipse XDB-C8 column. Electrospray MS/MS for these compounds was performed on an API 4000 triple quadruple mass spectrometer in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The calibration curve for 8-OHdG using its stable isotope-labeled internal standard was linear in the range of 0.05-10 ng/mL, and the detection limit was 8.3 pg/mL. The intra-day and inter-day precision (relative standard deviations) were below 3.1% and 9.6% (n=5), respectively. This method was applied successfully to the analysis of urine samples without any other pretreatment and interference peaks, with good recovery rates above 91% in spiked urine samples. The limits of quantification of 8-OHdG and creatinine in 0.1 mL urine samples were about 0.32 and 0.69 ng/mL (S/N=10), respectively. This method was utilized to assess the effects of smoking, green tea drinking and alcohol drinking on the urinary excretion of 8-OHdG. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. A New Generation of Thermal Desorption Technology Incorporating Multi Mode Sampling (NRT/DAAMS/Liquid Agent) for Both on and off Line Analysis of Trace Level Airbone Chemical Warfare Agents

    International Nuclear Information System (INIS)

    Roberts, G. M.

    2007-01-01

    A multi functional, twin-trap, electrically-cooled thermal desorption (TD) system (TT24-7) will be discussed for the analysis of airborne trace level chemical warfare agents. This technology can operate in both military environments (CW stockpile, or destruction facilities) and civilian locations where it is used to monitor for accidental or terrorist release of acutely toxic substances. The TD system interfaces to GC, GCMS or direct MS analytical platforms and provides for on-line continuous air monitoring with no sampling time blind spots and within a near real time (NRT) context. Using this technology enables on-line sub ppt levels of agent detection from a vapour sample. In addition to continuous sampling the system has the capacity for off-line single (DAAMS) tube analysis and the ability to receive an external liquid agent injection. The multi mode sampling functionality provides considerable flexibility to the TD system, allowing continuous monitoring of an environment for toxic substances plus the ability to analyse calibration standards. A calibration solution can be introduced via a conventional sampling tube on to either cold trap or as a direct liquid injection using a conventional capillary split/splitless injection port within a gas chromatograph. Low level (linearity) data will be supplied showing the TT24-7 analyzing a variety of CW compounds including free (underivitised) VX using the three sampling modes described above. Stepwise changes in vapor generated agent concentrations will be shown, and this is cross referenced against direct liquid agent introduction, and the tube sampling modes. This technology is in use today in several geographies around the world in both static and mobile analytical laboratories. (author)

  17. Methodology for the selection of routes for international cross-border line projects involving multiple objectives and decision-makers in the analyses of restrictions and environmental possibilities

    International Nuclear Information System (INIS)

    Angel S, Enrique; Cadena, Luis Fernando

    2005-01-01

    A scheme was developed and applied to select the optimum environmental route for international cross-border line projects, in a decision making context involving multiple objectives and multiple decision-makers, the project studied was the electricity interconnection for central America (SIEPAC) for which a prospective assessment was carried out regarding the restrictions and possibilities in the light of the Colombian environmental dimensions management model. The methodology proposed followed these stages: Definition and approval of the structure of environmental restriction and criticality variables, sectorization and selection of complex sections, definition of decision-makers for multi-objective analysis; design and application of consultation tool; definition and modeling of options applying SIG; sensitivity analysis of alternative routes and project's environment management. Different options were identified for insertion and permanence of the project according to the criteria of various interest groups and actors consulted: environmental authorities, electricity companies, scientific community and civil society

  18. Improved method for the determination of serotonin in plasma by high-performance liquid chromatography using on-line sample pre-treatment

    NARCIS (Netherlands)

    Takkenberg, B.; Endert, E.; van Ingen, H. E.; Ackermans, M.

    1991-01-01

    An improved method for the determination of serotonin in platelet-rich plasma (PRP) and platelet-poor plasma (PPP), by reversed-phase high-performance liquid chromatography with electrochemical detection and direct plasma injection, is described. The chromatographic system comprises a strong

  19. Analysis of Caffeic Acid Extraction From Ocimum gratissimum Linn. by High Performance Liquid Chromatography and its Effects on a Cervical Cancer Cell Line

    Directory of Open Access Journals (Sweden)

    Je-Chiuan Ye

    2010-09-01

    Conclusion: This paper shows that high performance liquid chromatography is a suitable analytical method for determining caffeic acid levels in O. gratissimum, Ju ZenTa, and several vegetable oils. Caffeic acid can suppress the proliferation of HeLa cells.

  20. Supported liquid membrane extraction coupled in-line to commercial capillary electrophoresis for rapid determination of formate in undiluted blood samples

    Czech Academy of Sciences Publication Activity Database

    Pantůčková, Pavla; Kubáň, Pavel; Boček, Petr

    2013-01-01

    Roč. 1299, JUL (2013), s. 33-39 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : capillary electrophoresis * supported liquid membranes * methanol intoxication Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.258, year: 2013

  1. Development of an automated on-line pepsin digestion-liquid chromatography-tandem mass spectrometry configuration for the rapid analysis of protein adducts of chemical warfare agents

    NARCIS (Netherlands)

    Carol-Visser, J.; van der Schans, M.; Fidder, A.; Huist, A.G.; van Baar, B.L.M.; Irth, H.; Noort, D.

    2008-01-01

    Rapid monitoring and retrospective verification are key issues in protection against and non-proliferation of chemical warfare agents (CWA). Such monitoring and verification are adequately accomplished by the analysis of persistent protein adducts of these agents. Liquid chromatography-mass

  2. Liquid chromatography-tandem mass spectrometry quantification of 6-thioguanine in DNA using endogenous guanine as internal standard

    DEFF Research Database (Denmark)

    Jacobsen, Jack Hummeland; Schmiegelow, Kjeld; Nersting, Jakob

    2012-01-01

    was estimated at 63% (RSD 26%), which is corrected for by the internal standard resulting in stable quantification. The TG levels found were above the LOQ in 18 out of 18 childhood leukemia patients on 6-mercaptopurine/methotrexate maintenance therapy (median 377, range 45-1190 fmol/μg DNA) with intra...

  3. Proceedings of the International Workshop on Current Challenges in Liquid and Glass Science, (The Cosener's House, Abingdon 10-12 January 2007).

    Science.gov (United States)

    Hannon, Alex C; Salmon, Philip S; Soper, Alan K

    2007-10-17

    to the success of the meeting. The present special issue stems from the interest of many of those present to collect their work into a single volume. [Formula: see text] The workshop participants. Spencer Howells is in the centre of the front row. DEDICATION William Spencer Howells It is a great pleasure to dedicate this Special Issue on Current Challenges in Liquid and Glass Science to the many contributions Spencer Howells has made to the structure and dynamics of liquids and glasses over some 40 years of work with the neutron scattering technique. After completing a first degree in Physics at Cambridge in 1966, Spencer started a postgraduate program with Gordon Squires at Cambridge, exploiting the early neutron scattering instrumentation that was available in those days at the Harwell reactors. This resulted in a Ph D thesis in 1970 on the twin topics of 'Neutron scattering of phonons in single-crystal molybdenum, using a time-of-flight chopper spectrometer (Part I)' and 'Neutron studies of the metal-insulator transition (Part II)'. The thesis was split into two parts because the hydrogen moderator blew-up on the chopper instrument used for the first part! From Cambridge, he moved to Leicester University as a post-doctoral Fellow with John Enderby, who was setting up a programme of study on the liquid state of matter. Here Spencer continued to use the Harwell Dido reactor, now to measure the structure of liquid metal alloys and molten salts - a topic that has kept his interest right through into retirement. He also initiated the first structural studies of aqueous solutions using neutron scattering, eventually pursuing this work as one of the first UK users of the Institut Laue-Langevin, Grenoble, France (ILL). In 1973 Spencer moved to the ILL, which was then and has remained the world's leading steady-state neutron source, as instrument scientist on IN10, the quasi-elastic neutron scattering beam line. Here he led the field in developing the quasi

  4. Solid and liquid biofuels markets in Finland. A study on international biofuels trade. IEA bioenergy task 40 and EUROBIONET II. Country report of Finland

    International Nuclear Information System (INIS)

    Heinimoe, J.; Alakangas, E.

    2006-01-01

    This study considered the current situation of solid and liquid biofuels markets and international biofuels trade in Finland and identified the challenges of the emerging international biofuels markets for Finland. The fact that industry consumes more than half of the total primary energy, widely applied combined heat and power production (CHP) and a high share of biofuels in the total energy consumption are specific to the Finnish energy system. One third of the electricity is generated in CHP plants. As much as 27% of the total energy consumption is met by using wood and peat, which makes Finland the leading country in the use of biofuels. Finland has made a commitment to maintain greenhouse gas emissions at the 1990 level at the highest during the period 2008-2012. The Finnish energy policy aims to achieve the target, and a variety of measures are taken to promote the use of renewable energy sources and especially wood fuels. In this study, the wooden raw material streams of the forest industry were included the international biofuels trade in addition to biomass streams that are traded for energy production. In 2004, as much as 45% of the raw wood imported into Finland ended up in energy production. The total international trading of biofuels was evaluated at 72 PJ, of which the majority, 58 PJ, was raw wood. About 22% of wood based energy in Finland originated from imported raw wood. Tall oil and wood pellets composed the largest export streams of biofuels. The annual turnover of international biofuels trade was estimated at about euro 90 million for direct trade and at about euro 190 million for indirect trade. The forest industry as the biggest user of wood, and the producer and user of wood fuels has a central position in biomass and biofuels markets in Finland. Lately, the international aspects of Finnish biofuels markets have been emphasised as the import of raw wood and the export of wood pellets have increased. Expanding the use of biofuels in the road

  5. Germ line mutations of mismatch repair genes in hereditary nonpolyposis colorectal cancer patients with small bowel cancer: International Society for Gastrointestinal Hereditary Tumours Collaborative Study

    DEFF Research Database (Denmark)

    Park, Jae-Gahb; Kim, Duck-Woo; Hong, Chang Won

    2006-01-01

    PURPOSE: The aim of study was to determine the clinical characteristics and mutational profiles of the mismatch repair genes in hereditary nonpolyposis colorectal cancer (HNPCC) patients with small bowel cancer (SBC). EXPERIMENTAL DESIGN: A questionnaire was mailed to 55 members of the Internatio......PURPOSE: The aim of study was to determine the clinical characteristics and mutational profiles of the mismatch repair genes in hereditary nonpolyposis colorectal cancer (HNPCC) patients with small bowel cancer (SBC). EXPERIMENTAL DESIGN: A questionnaire was mailed to 55 members...... of the International Society for Gastrointestinal Hereditary Tumours, requesting information regarding patients with HNPCC-associated SBC and germ line mismatch repair gene mutations. RESULTS: The study population consisted of 85 HNPCC patients with identified mismatch repair gene mutations and SBCs. SBC was the first...... HNPCC-associated malignancy in 14 of 41 (34.1%) patients for whom a personal history of HNPCC-associated cancers was available. The study population harbored 69 different germ line mismatch repair gene mutations, including 31 mutations in MLH1, 34 in MSH2, 3 in MSH6, and 1 in PMS2. We compared...

  6. Efficacy of Second-line Targeted Therapy for Renal Cell Carcinoma According to Change from Baseline in International Metastatic Renal Cell Carcinoma Database Consortium Prognostic Category

    DEFF Research Database (Denmark)

    Davis, Ian D; Xie, Wanling; Pezaro, Carmel

    2017-01-01

    BACKGROUND: We hypothesized that changes in International Metastatic Renal Cell Carcinoma Database Consortium (IMDC) prognostic category at start of second-line therapy (2L) for metastatic renal cell carcinoma (mRCC) might predict response. OBJECTIVE: To assess outcomes of 2L according to type...... of therapy and change in IMDC prognostic category. DESIGN, SETTING, AND PARTICIPANTS: We performed a retrospective review of the IMDC database for mRCC patients who received first-line (1L) VEGF inhibitors (VEGFi) and then 2L with VEGFi or mTOR inhibitors (mTORi). IMDC prognostic categories were defined......% confidence interval [CI] 12.0-19.0 for VEGFi; 20.2 mo, 95% CI 14.3-26.1 for mTORi; AHR 1.53, 95% CI 1.04-2.24; adjusted p=0.03). CONCLUSIONS: Changes in IMDC prognostic category predict the subsequent clinical course for patients with mRCC and provide a rational basis for selection of subsequent therapy...

  7. THE USE OF STABILIZED LIQUIDE CHLORINE DIOXIDE (ClO2 FOR INTERNAL WATER SUPPLY SYSTEM SANITATION OF FARM WITH LAYING FLOCK AFFECTED BY COLISEPTICEMIA

    Directory of Open Access Journals (Sweden)

    Abdulah Gagić

    2014-03-01

    Full Text Available A successful and harmless method for rehabilitation of hygienic status of water and its supply system using a stabilized liquid chlorine dioxide solution on a farm of the laying hens affected by severe colisepticemia is described. Source of infection was drinking water contaminated by slurry from two pig facilities located above the water tank. The contaminated water caused the emergence of biofilm consisting mainly of coliform bacteria on the interior surfaces of the plastic pipes. Through drinking the contaminated water the infection of the laying flocks occurred. With the aim of improving the flocks’ health status, a programme of sanitary treatment of external and internal water supply system and water was created and implemented. In order to prevent biofilm formation and improve sanitation prescribed was the use of stabilized liquid chlorine dioxide (ClO2 in the 4‰ concentration for so-called night "shock" treatments, and 2‰ concentration for prophylactic daily disinfection of drinking water. With the improvement of the flocks’ health status, the "shock" treatments with ClO2 were repeated in the upcoming months. As an add-on therapy, 40 mg per bird of vitamin C through drinking water for three days was prescribed. The use of non-resorptive antibiotics, AD3E vitamins and amino acid supplements was excluded because they had failed to improve the flocks’ health status in the acute phase. Therefore, the sanitation programme based on the use of stabilized liquid ClO2 in the water supply system of the laying flocks affected by severe colisepticemia resulted in radical decrease of mortality during the next three months. Key words: chlorine dioxide, biofilm, sanitation, disinfection, colisepticemia

  8. Fast and simple screening for the simultaneous analysis of seven metabolites derived from five volatile organic compounds in human urine using on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chiang, Wen-Chieh; Chen, Chao-Yu; Lee, Ting-Chen; Lee, Hui-Ling; Lin, Yu-Wen

    2015-01-01

    Recently, the International Agency for Research on cancer classified outdoor air pollution and particulate matter from outdoor air pollution as carcinogenic to humans (IARC Group 1), based on sufficient evidence of carcinogenicity in humans and experimental animals and strong mechanistic evidence. In particular, a wide variety of volatile organic compounds (VOCs) are volatized or released into the atmosphere and can become ubiquitous, as they originate from many different natural and anthropogenic sources, such as paints, pesticides, vehicle exhausts, cooking fumes, and tobacco smoke. Humans may be exposed to VOCs through inhalation, ingestion, or dermal contact, which may increase the risk of leukemia, birth defects, neurocognitive impairment, and cancer. Therefore, the focus of this study was the development of a simple, effective and rapid sample preparation method for the simultaneous determination of seven metabolites (6 mercaptic acids+t,t-muconic acid) derived from five VOCs (acrylamide, 1,3-butadiene, acrylonitrile, benzene, and xylene) in human urine by using automated on-line solid-phase extraction (SPE) coupled with liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). An aliquot of each diluted urinary sample was directly injected into an autosampler through a trap column to reduce contamination, and then the retained target compounds were eluted by back-flush mode into an analytical column for separation. Negative electrospray ionization tandem mass spectrometry was utilized for quantification. The coefficients of correlation (r(2)) for the calibration curves were greater than 0.995. Reproducibility was assessed by the precision and accuracy of intra-day and inter-day precision, which showed results for coefficient of variation (CV) that were low 0.9 to 6.6% and 3.7 to 8.5%, respectively, and results for recovery that ranged from 90.8 to 108.9% and 92.1 to 107.7%, respectively. The limits of detection (LOD) and limits of

  9. Political goals during liquidation of masonic organizations by Joint State Political Directorate – People's Commissariat of Internal Affairs in USSR in the 1920s–1930s

    Directory of Open Access Journals (Sweden)

    Ermakov V.A.

    2017-04-01

    Full Text Available this research is dedicated to the political specificity of elimination of «masonic underground organization» by soviet special forces in USSR. The issue of relations between communist movements with political masonry was also considered in the article. It appears that in the beginning of 1920s «freemasons» planned prospects in cooperation with Bolsheviks, while having hidden goal to «cover» Soviet government with masonic ideas. Masons of 1920s were quite satisfied with Bolshevism as a weapon to eradicate Russian national self-awareness and its Orthodox religion. Liquidation process of masonic underground, which started in 1925, was conditioned by inner-party strife between «Stalinists», conducting anti-masonic and anti-Zionist campaigns, and «Trotskyists», who appeared to be a weapon of international masonic politics in Soviet Russia. Authors conclude that liquidation of occult-masonic underground in USSR had several political goals: covering communist party leaders' masonic past, elimination masons as potential western secret service agents, threatening conservative intelligentsia, exposure masonic people from the environment of Soviet officials and cultural elites, extermination masonic alternative of communistic ideology and preparation of «grand terror» against «Lenin's guard».

  10. Performance Characterization of Loctite (Registered Trademark) 242 and 271 Liquid Locking Compounds (LLCs) as a Secondary Locking Feature for International Space Station (ISS) Fasteners

    Science.gov (United States)

    Dube, Michael J.; Gamwell, Wayne R.

    2011-01-01

    Several International Space Station (ISS) hardware components use Loctite (and other polymer based liquid locking compounds (LLCs)) as a means of meeting the secondary (redundant) locking feature requirement for fasteners. The primary locking method is the fastener preload, with the application of the Loctite compound which when cured is intended to resist preload reduction. The reliability of these compounds has been questioned due to a number of failures during ground testing. The ISS Program Manager requested the NASA Engineering and Safety Center (NESC) to characterize and quantify sensitivities of Loctite being used as a secondary locking feature. The findings and recommendations provided in this investigation apply to the anaerobic LLCs Loctite 242 and 271. No other anaerobic LLCs were evaluated for this investigation. This document contains the findings and recommendations of the NESC investigation

  11. Speciation of eight arsenic compounds in human urine by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Four anionic and four cationic arsenic compounds in urine were separated by anion- and cation-exchange high-performance liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS) at m/z 75. The species were the anions arsenite, arsenate, monomethylarsonate...... and dimethylarsinate and the cations arsenobetaine, trimethylarsine oxide, arsenocholine and the tetramethylarsonium ion. Hexahydroxyantimonate(III) was co-chromatographed with the arsenic anions but detected at m/z 121 and used as an internal standard for their qualitative analysis. Arsenite was prone to oxidation....... The argon chloride interference at m/z 75 was eliminated by chromatographic separation of the chloride present in the sample from the arsenic analytes. The ClO+ ion detected at m/z 51 and 53 was used to monitor the retention time of chloride in the anion-exchange system. The chloride eluted about 100 s...

  12. Proceedings: On-line monitoring of corrosion an water chemistry for the electric power utility industry: An EPRI workshop held during the 12th International Corrosion Congress

    International Nuclear Information System (INIS)

    Licina, G.

    1994-03-01

    A two-day EPRI workshop on On-line Monitoring of Corrosion and Water Chemistry for the Electric Power Utility Industry included discussions on a variety of methods for the online monitoring of corrosion and water chemistry in a power plant environment. The workshop was held September 22 and 23, 1993 in Houston, Texas, as a part of the 12th International Corrosion Congress sponsored by NACE International. Methods in various stages of development, from laboratory demonstrations to in-plant monitoring, were presented by authors from all over the world. Recent developments in corrosion monitoring and the detection of specific chemical species in power plant environments have utilized a variety of electrochemical methods (both AC and DC), electrical resistance techniques, and potential drop techniques to evaluate crack extension. Other approaches, such as Raman spectroscopy of corroding surfaces, Specific ion detectors, and X-ray fluorescence and ion chromatography to analyze corrosion products have been demonstrated in the laboratory. Techniques that were described in the twenty-three technical papers included: Electrochemical noise, Electrical resistance, Field signature method, Linear polarization resistance, Neutron activation, Corrosion potential monitoring, Electrochemical detection of biofilm activity, Analysis of corrosion products by X-ray fluorescence, Potential drop method for assessing environmentally assisted crack growth, Harmonic impedance spectroscopy, Contact electric resistance, Conductivity and hydrogen sensors, Solid state methods for tracking oxygen and pH, and Raman spectroscopy. Individual papers are indexed separately

  13. First on-line survey of an international multidisciplinary working group (MightyMedic) on current practice in diagnosis, therapy and follow-up of dyslipidemias.

    Science.gov (United States)

    Stefanutti, C; D'Alessandri, G; Petta, A; Harada-Shiba, M; Julius, U; Soran, H; Moriarty, P M; Romeo, S; Drogari, E; Jaeger, B R

    2015-05-01

    The MightyMedic (Multidisciplinary International Group for Hemapheresis TherapY and MEtabolic DIsturbances Contrast) Working Group has been founded in 2013. The leading idea was to establish an international network of interdisciplinary nature aimed at working to cross national borders research projects, clinical trials, educational initiatives (meetings, workshops, summer schools) in the field of metabolic diseases, namely hyperlipidemias, and diabetes, preventive cardiology, and atherosclerosis. Therapeutic apheresis, its indications and techniques, is a parallel field of investigation. The first on-line survey of the Group has been completed in the first half of 2014. The survey included # 24 Centers in Italy, Germany, Greece, UK, Sweden, Japan and USA. Relevant data have been collected on current practice in diagnosis, therapy and follow-up of dyslipidemias. 240 subjects with hyperlipidemia and treated with lipoprotein apheresis have been reported in the survey, but a large percentage of patients (35%) who could benefit from this therapeutic option are still treated by conventional drug approach. Genetic molecular diagnosis is performed in only 33% of patients while Lipoprotein(a) (Lp(a)) is included in cardiovascular disease risk assessment in 71% of participating Centers. New detailed investigations and prospective multicenter studies are needed to evaluate changes induced by the impact of updated indications and strategies, as well as new treatment options, targeting standardization of therapeutic and diagnostic approaches. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. An On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters

    Directory of Open Access Journals (Sweden)

    Michela Mazzoni

    2015-01-01

    Full Text Available An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms. This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters.

  15. An On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters

    Science.gov (United States)

    Mazzoni, Michela; Rusconi, Marianna; Valsecchi, Sara; Martins, Claudia P. B.; Polesello, Stefano

    2015-01-01

    An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE) procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms) and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms). This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters. PMID:25834752

  16. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  17. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  18. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    International Nuclear Information System (INIS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-01-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring. (c)

  19. Effects of push/pull perfusion and ultrasonication on the extraction efficiencies of phthalate esters in sports drink samples using on-line hollow-fiber liquid-phase microextraction.

    Science.gov (United States)

    Chao, Yu-Ying; Lee, Chien-Hung; Chien, Tzu-Yang; Shih, Yu-Hsuan; Lu, Yin-An; Kuo, Ting-Hsuan; Huang, Yeou-Lih

    2013-08-28

    In previous studies, we developed a process, on-line ultrasound-assisted push/pull perfusion hollow-fiber liquid-phase microextraction (UA-PPP-HF-LPME), combining the techniques of push/pull perfusion (PPP) and ultrasonication with hollow-fiber liquid-phase microextraction (HF-LPME), to achieve rapid extraction of acidic phenols from water samples. In this present study, we further evaluated three more-advanced and novel effects of PPP and ultrasonication on the extraction efficiencies of neutral high-molecular-weight phthalate esters (HPAEs) in sports drinks. First, we found that inner-fiber fluid leakage occurs only in push-only perfusion-based and pull-only perfusion-based HF-LPME, but not in the PPP mode. Second, we identified a significant negative interaction between ultrasonication and temperature. Third, we found that the extraction time of the newly proposed system could be shortened by more than 93%. From an investigation of the factors affecting UA-PPP-HF-LPME, we established optimal extraction conditions and achieved acceptable on-line enrichment factors of 92-146 for HPAEs with a sampling time of just 2 min.

  20. Observation of a three-dimensional vortex-line liquid in a highly c-axis-oriented (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed tape

    International Nuclear Information System (INIS)

    Sun, Y.; Xu, G.; Du, J.; Zhou, Y.; Zeng, R.; Fu, X.; Hua, P.; Zhang, Y.

    1996-01-01

    We have measured the temperature dependence of resistance of a highly c-axis-oriented (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O x silver-sheathed tape in the mixed state using the dc flux transformer geometry. In the vortex fluid regime, we have observed the onset of a nonlocal conductivity which corresponds to the peak (T peak ) in R bot (T) curves. This can be explained qualitatively in terms of the vortex decoupling which arises from an increased thermal fluctuation. At T peak , the vortices are three dimensional (3D) in character. This behavior is quite different from the results obtained recently by Safar et al. [Phys. Rev. Lett. 69, 824 (1992)] and Busch et al. [Phys. Rev. Lett. 69, 522 (1992)] in Bi 2 Sr 2 CaCu 2 O y single crystals using the same measuring method. Their results show that the vortices are two dimensional in character. The difference of the vortex dimensionality between (Bi,Pb) 2 Sr 2 Ca 2 Cu 3 O x and Bi 2 Sr 2 CaCu 2 O y superconductors in the vortex liquid regime may be attributed to different anisotropies due to their different crystal structures and pinning disorders. In a 3D vortex line liquid, the results reveal that dissipation seems to originate from the thermally activated plastic motion of a pinned vortex line liquid. The field and temperature dependence of the activation energy is as follows: U(H,T)=U 0 (1-T/T c )H -0.45 . copyright 1996 The American Physical Society

  1. The influence of atomizer internal design and liquid physical properties on effervescent atomizing of coal-water slurry

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Meng; Duan, Yufeng [Southeast Univ., Nanjing (China). Inst. of Thermal Engineering

    2013-07-01

    This study investigated the dependence of effervescent atomizing of coal-water slurry (CWS) on atomizer internal design and fluid properties. Results demonstrate that internal design of atomizer and fluid properties directly affect the two-phase flow pattern inside the atomizer which consequently affects the spray quality. The influence of mixing chamber length on spray quality is not significant at the ALR of 0.15 except for spray 0.75 glycerol/0.248 water/0.002 xanthan mixture. The same trend also found in the effect of angle of aeration holes at ALR of 0.15. Large diameter of the inclined aeration holes shows small SMD for water. The consistency index of fluids has no effect on the spray quality and Sauter Mean Diameter (SMD) increases when polymer additions were added to the glycerin-water mixture. The radial profile of SMD for spray water are almost flat, however, the largest SMD can be obtained at the edge of spray for three other fluids.

  2. CASH AND LIQUIDITY/LIQUIDITY AND LIQUIDITY RATIO

    Directory of Open Access Journals (Sweden)

    BEATRIX LIGHEZAN BREUER

    2012-12-01

    Full Text Available The present paper aims to present the correlation as well as the differences between liquidity/cash and liquidity ratio in terms of economic entities. Researches on this topic are based on the opinions of some specialists in accounting and in the economic-financial analysis, as well as on the national legal stipulations and the ones set out in the International Accounting Standards, the Financial report, respectively. The object of this paper is represented by the correlation between liquidity/cash and liquidity ratios representing the liquidity as current assets, assets implied in the determination of liquidity ratios. The end of the paper consists of the conclusions drawn from the issues presented in the paper but also our views on this research topic.

  3. Development of an on-line high performance liquid chromatography detection system for human cytochrome P450 1A2 inhibitors in extracts of natural products

    NARCIS (Netherlands)

    Jeurissen, S.M.F.; Claassen, F.W.; Havlik, J.; Bouwmans, E.E.; Cnubben, N.H.P.; Sudhölter, E.J.R.; Rietjens, I.M.C.M.; Beek, T.A. van

    2007-01-01

    An on-line HPLC screening method for detection of inhibitors of human cytochrome P450 1A2 in extracts was developed. HPLC separation of extracts is connected to a continuous methoxyresorufin-O-demethylation (MROD) assay in which recombinant human P450 1A2 converts methoxyresorufin to its fluorescent

  4. Determination of the sulfur mustard hydrolysis product thiodiglycol by microcolumn liquid chromatography coupled on-line with sulfur flame photometric detection using large-volume injections and peak

    NARCIS (Netherlands)

    Hooijschuur, E.W.J.; Kientz, C.E.; Brinkman, U.A.T.

    1999-01-01

    A selective, direct and relatively rapid method has been developed for the determination of thiodiglycol (TDG) in aqueous samples. TDG is the main hydrolysis product of the chemical warfare agent sulfur mustard. The method of analysis is based on the on-line coupling of reversed-phase microcolumn

  5. An on-line normal-phase high performance liquid chromatography method for the rapid detection of radical scavengers in non-polar food matrixes

    NARCIS (Netherlands)

    Zhang, Q.; Klift, van der E.J.C.; Janssen, H.G.; Beek, van T.A.

    2009-01-01

    An on-line method for the rapid pinpointing of radical scavengers in non-polar mixtures like vegetable oils was developed. To avoid problems with dissolving the sample, normal-phase chromatography on bare silica gel was used with mixtures of hexane and methyl tert-butyl ether as the eluent. The high

  6. Urea functionalized surface-bonded sol-gel coating for on-line hyphenation of capillary microextraction with high-performance liquid chromatography.

    Science.gov (United States)

    Jillani, Shehzada Muhammad Sajid; Alhooshani, Khalid

    2018-03-30

    Sol-gel urea functionalized-[bis(hydroxyethyl)amine] terminated polydimethylsiloxane coating was developed for capillary microextraction-high performance liquid chromatographic analysis from aqueous samples. A fused silica capillary is coated from the inside with surface bonded coating material and is created through in-situ sol-gel reaction. The urea-functionalized coating was immobilized to the inner surface of the capillary by the condensation reaction of silanol groups of capillary and sol-solution. The characterization of the coating material was successfully done by using X-ray photoelectron spectroscopy, thermogravimetric analysis, field emission scanning electron microscope, and energy dispersive X-ray spectrometer. To make a setup of online capillary microextraction-high performance liquid chromatography, the urea functionalized capillary was installed in the HPLC manual injection port. The analytes of interest were pre-concentrated in the coated sampling loop, desorbed by the mobile phase, chromatographically separated on C-18 column, and analyzed by UV detector. Sol-gel coated capillaries were used for online extraction and high-performance liquid chromatographic analysis of phenols, ketones, aldehydes, and polyaromatic hydrocarbons. This newly developed coating showed excellent extraction for a variety of analytes ranging from highly polar to non-polar in nature. The analysis using sol-gel coating showed excellent overall sensitivity in terms of lower detection limits (S/N = 3) for the analytes (0.10 ng mL -1 -14.29 ng mL -1 ) with acceptable reproducibility that is less than 12.0%RSD (n = 3). Moreover, the capillary to capillary reproducibility of the analysis was also tested by changing the capillary of the same size. This provided excellent%RSD of less than 10.0% (n = 3). Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Coenzyme Q10 quantification in muscle, fibroblasts and cerebrospinal fluid by liquid chromatography/tandem mass spectrometry using a novel deuterated internal standard.

    Science.gov (United States)

    Duberley, Kate E C; Hargreaves, Iain P; Chaiwatanasirikul, Korn-Anong; Heales, Simon J R; Land, John M; Rahman, Shamima; Mills, Kevin; Eaton, Simon

    2013-05-15

    Neurological dysfunction is common in primary coenzyme Q10 (2,3-dimethoxy, 5-methyl, 6-polyisoprene parabenzoquinone; CoQ10 ; ubiquinone) deficiencies, the most readily treatable subgroup of mitochondrial disorders. Therapeutic benefit from CoQ10 supplementation has also been noted in other neurodegenerative diseases. CoQ10 can be measured by high-performance liquid chromatography (HPLC) in plasma, muscle or leucocytes; however, there is no reliable method to quantify CoQ10 in cerebrospinal fluid (CSF). Additionally, many methods use CoQ9 , an endogenous ubiquinone in humans, as an internal standard. Deuterated CoQ10 (d6 -CoQ10 ) was synthesised by a novel, simple, method. Total CoQ10 was measured by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using d6 -CoQ10 as internal standard and 5 mM methylamine as an ion-pairing reagent. Chromatography was performed using a Hypsersil GOLD C4 column (150 × 3 mm, 3 µm). CoQ10 levels were linear over a concentration range of 0-200 nM (R(2) = 0.9995). The lower limit of detection was 2 nM. The inter-assay coefficient of variation (CV) was 3.6% (10 nM) and 4.3% (20 nM), and intra-assay CV 3.4% (10 nM) and 3.6% (20 nM). Reference ranges were established for CoQ10 in CSF (5.7-8.7 nM; n = 17), fibroblasts (57.0-121.6 pmol/mg; n = 50) and muscle (187.3-430.1 pmol/mg; n = 15). Use of d6 -CoQ10 internal standard has enabled the development of a sensitive LC/MS/MS method to accurately determine total CoQ10 levels. Clinical applications of CSF CoQ10 determination include identification of patients with cerebral CoQ10 deficiency, and monitoring CSF CoQ10 levels following supplementation. Copyright © 2013 John Wiley & Sons, Ltd.

  8. A fast and sensitive method for the simultaneous analysis of a wide range of per- and polyfluoroalkyl substances in indoor dust using on-line solid phase extraction-ultrahigh performance liquid chromatography-time-of-flight-mass spectrometry.

    Science.gov (United States)

    Padilla-Sánchez, Juan Antonio; Haug, Line Småstuen

    2016-05-06

    A fast and sensitive method for simultaneous determination of 18 traditional and 6 alternative per- and polyfluoroalkyl substances (PFASs) using solid-liquid extraction (SLE), off-line clean-up using activated carbon and on-line solid phase extraction-ultrahigh performance liquid chromatography-time-of-flight-mass spectrometry (on-line SPE-UHPLC-TOF-MS) was developed. The extraction efficiency was studied and recoveries in range the 58-114% were obtained. Extraction and injection volumes were also optimized to 2mL and 400μL, respectively. The method was validated by spiking dust from a vacuum cleaner bag that had been found to contain low levels of the PFASs in focus. Low method detection limits (MDLs) and method quantification limits (MQLs) in the range 0.008-0.846ngg(-1) and 0.027-2.820ngg(-1) were obtained, respectively. For most of the PFASs, the accuracies were between 70 and 125% in the range from 2 to100ngg(-1) dust. Intra-day and inter-day precisions were in general well below 30%. Analysis of a Standard Reference Material (SRM 2585) showed high accordance with results obtained by other laboratories. Finally, the method was applied to seven indoor dust samples, and PFAS concentrations in the range 0.02-132ngg(-1) were found. The highest median concentrations were observed for some of the alternative PFASs, such as 6:2-diPAP (25ngg(-1)), 8:2-diPAP (49ngg(-1)), and PFOPA (23ngg(-1)), illustrating the importance of inclusion of new PFASs in the analytical methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. High-performance liquid chromatographic analysis of cyclosporin A in rat blood and liver using a commercially available internal standard.

    Science.gov (United States)

    Chimalakonda, Anjaneya P; Shah, Rakhi B; Mehvar, Reza

    2002-05-25

    All the available HPLC assays of cyclosporin A (CyA) use internal standards that are not commercially available. Our purpose was to develop an HPLC assay for measurements of CyA in rat blood and liver using a commercially available internal standard (I.S.). After the addition of tamoxifen (I.S.), blood (0.25 ml) or the liver homogenate (1 ml) samples were extracted into a mixture of ether:methanol (95:5). The residue after evaporation of the organic layer was dissolved in 200 microl of an injection solution and washed with 1 ml of hexane before analysis. The separation was achieved using an LC-1 column (70 degrees C) with a mobile phase of methanol-acetonitrile-0.01 M KH(2)PO(4) (50:25:25, v/v) and a flow-rate of 1 ml/min. Detection was at 205 nm. Cyclosporin A and I.S. eluted at 5 and 7 min, respectively, free from endogenous peaks. Linear relationships (r>0.98) were observed between the CyA:I.S. peak area ratios and the CyA concentrations within the range of 0.2-10 microg/ml for blood and 0.1-4 microg/ml for the liver homogenates. The intra- and inter-run C.V.s and errors for both the blood and liver samples were <15%. The extraction efficiency (n=5) was close to 100% for both CyA and I.S. in both blood and liver homogenates. The lower limit of quantitation of the assay was 0.2 or 0.1 microg/ml based on 250 microl of blood or 1 ml of liver homogenate, respectively. The assay was capable of measuring blood and liver concentrations of CyA in a rat injected intravenously with a single 5-mg/kg dose of the drug.

  10. Speciation of four selenium compounds using high performance liquid chromatography with on-line detection by inductively coupled plasma mass spectrometry or flame atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Pedersen, Gitte Alsing; Larsen, Erik Huusfeldt

    1997-01-01

    An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination...... spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 sigma) achieved by the HPLC-FAAS system was 1 mg L-1 of selenium (100 mu L injections) for each of the four...

  11. Determination of water-soluble vitamins in infant milk and dietary supplement using a liquid chromatography on-line coupled to a corona-charged aerosol detector.

    Science.gov (United States)

    Márquez-Sillero, Isabel; Cárdenas, Soledad; Valcárcel, Miguel

    2013-10-25

    A simple and rapid method for the simultaneous determination of seven water-soluble vitamins (thiamine, folic acid, nicotinic acid, ascorbic acid, pantothenic acid, pyridoxine and biotin) was developed by high performance liquid chromatographic separation and corona-charged aerosol detection. The water-soluble vitamins were separated on a Lichrosorb RP-C18 column under isocratic conditions with a mobile phase consisting of 0.05 M ammonium acetate:methanol 90:10 (v/v) at the flow rate 0.5 mL min(-1). The vitamins were extracted from the infant milk (liquid and powder format) using a precipitation step with 2.5 M acetic acid remaining the analyte in the supernatant. As far as dietary supplements are concerned, only a dilution with distilled water was required. The detection limits ranged from 0.17 to 0.62 mg L(-1) for dietary supplements and 1.7 to 6.5 mg L(-1) for milk samples. The precision of the method was evaluated in terms of relative standard deviation (%, RSD) under repeatability and reproducibility conditions, being the average values for each parameter 2.6 and 2.7 for dietary supplements and 4.3 and 4.6 for milk samples. The optimized method was applied to different infant milk samples and dietary supplements. The results of the analysis were in good agreement with the declared values. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Balest, Lydia; Murgolo, Sapia; Sciancalepore, Lucia; Montemurro, Patrizia; Abis, Pier Paolo; Pastore, Carlo; Mascolo, Giuseppe

    2016-06-01

    An on-line solid phase extraction coupled with high-performance liquid chromatography in tandem with mass spectrometry (on-line SPE/HPLC/MS-MS) method for the determination of five microcystins and nodularin in surface waters at submicrogram per liter concentrations has been optimized. Maximum recoveries were achieved by carefully optimizing the extraction sample volume, loading solvent, wash solvent, and pH of the sample. The developed method was also validated according to both UNI EN ISO IEC 17025 and UNICHIM guidelines. Specifically, ten analytical runs were performed at three different concentration levels using a reference mix solution containing the six analytes. The method was applied for monitoring the concentrations of microcystins and nodularin in real surface water during a sampling campaign of 9 months in which the ELISA method was used as standard official method. The results of the two methods were compared showing good agreement when the highest concentration values of MCs were found. Graphical abstract An on-line SPE/HPLC/MS-MS method for the determination of five microcystins and nodularin in surface waters at sub μg L(-1) was optimized and compared with ELISA assay method for real samples.

  15. Comparison of ultra-violet and inductively coupled plasma-atomic emission spectrometry for the on-line quantification of selenium species after their separation by reversed-phase liquid chromatography

    International Nuclear Information System (INIS)

    Tsopelas, Fotios N.; Ochsenkuehn-Petropoulou, Maria Th.; Mergias, Ioannis G.; Tsakanika, Lambrini V.

    2005-01-01

    An analytical approach for selenium speciation using liquid chromatography (LC) coupled with ultra-violet (UV) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was developed. The separation of the investigated selenium species, selenites, selenates, selenomethionine, selenocystine, selenocystamine and dimethyldiselenide was accomplished in less than 6 min on a BIO Wide Pore RP-18 column using sodium salt of n-octanesulfonic acid as ion-pairing modifier. The on-line detection of the separated selenium species was performed using UV spectrometry at the optimum wavelength of 192 nm, obtained by the UV spectra of the investigated individual selenium species. ICP-AES was also used as element specific on-line detector, after its coupling with the chromatographic system. The UV and ICP-AES detectors were compared for their suitability, including sensitivity and detection limits, for the on-line quantification of the six selenium species. The developed LC-UV as well as LC-ICP-AES techniques were successfully applied to a selenized yeast candidate reference material, after its enzymatic extraction with protease XIV. It was found that the described LC-UV technique is suitable for the determination of selenomethionine, the main selenium compound in the yeast, with an accuracy of 5%, although the UV detector is not element specific and it is rarely used for selenium speciation. This finding can prove valuable for routine laboratories to perform selenium speciation in such materials

  16. My Retina Tracker™: An On-line International Registry for People Affected with Inherited Orphan Retinal Degenerative Diseases and their Genetic Relatives - A New Resource.

    Science.gov (United States)

    Fisher, Joan K; Bromley, Russell L; Mansfield, Brian C

    2016-01-01

    My Retina Tracker™ is a new on-line registry for people affected with inherited orphan retinal degenerative diseases, and their unaffected, genetic relatives. Created and supported by the Foundation Fighting Blindness, it is an international resource designed to capture the disease from the perspective of the registry participant and their retinal health care providers. The registry operates under an Institutional Review Board (IRB)-approved protocol and allows sharing of de-identified data with participants, researchers and clinicians. All participants sign an informed consent that includes selecting which data they wish to share. There is no minimum age of participation. Guardians must sign on behalf of minors, and children between the ages of 12 to 17 also sign an informed assent. Participants may compare their disease to others in the registry using graphical interpretations of the aggregate registry data. Researchers and clinicians have two levels of access. The first provides an interface to interrogate all data fields registrants have agreed to share based on their answers in the IRB informed consent. The second provides a route to contact people in the registry who may be eligible for studies or trials, through the Foundation.

  17. Second-Line Treatment Options in Non-Small-Cell Lung Cancer: Report From an International Experts Panel Meeting of the Italian Association of Thoracic Oncology

    NARCIS (Netherlands)

    Gridelli, Cesare; Baas, Paul; Barlesi, Fabrice; Ciardiello, Fortunato; Crinò, Lucio; Felip, Enriqueta; Gadgeel, Shirish; Papadimitrakopoulou, Vali; Paz-Ares, Luis; Planchard, David; Perol, Maurice; Hanna, Nasser; Sgambato, Assunta; Casaluce, Francesca; de Marinis, Filippo

    2017-01-01

    Non-small-cell lung cancer (NSCLC) patients inevitably progress to first-line therapy and further active treatments are warranted. In the past few years, new second-line therapies, beyond chemotherapy agents, have become available in clinical practice. To date, several options for the second-line

  18. CASH AND LIQUIDITY/LIQUIDITY AND LIQUIDITY RATIO

    OpenAIRE

    ADELA BREUER; MIHAELA LESCONI FRUMUSANU; BEATRIX LIGHEZAN BREUER; ANDRA MANCIU

    2012-01-01

    The present paper aims to present the correlation as well as the differences between liquidity/cash and liquidity ratio in terms of economic entities. Researches on this topic are based on the opinions of some specialists in accounting and in the economic-financial analysis, as well as on the national legal stipulations and the ones set out in the International Accounting Standards, the Financial report, respectively. The object of this paper is represented by the correlation between liquidit...

  19. Electron paramagnetic resonance line shifts and line shape changes due to heisenberg spin exchange and dipole-dipole interactions of nitroxide free radicals in liquids 8. Further experimental and theoretical efforts to separate the effects of the two interactions.

    Science.gov (United States)

    Peric, Mirna; Bales, Barney L; Peric, Miroslav

    2012-03-22

    The work in part 6 of this series (J. Phys. Chem. A 2009, 113, 4930), addressing the task of separating the effects of Heisenberg spin exchange (HSE) and dipole-dipole interactions (DD) on electron paramagnetic resonance (EPR) spectra of nitroxide spin probes in solution, is extended experimentally and theoretically. Comprehensive measurements of perdeuterated 2,2,6,6-tetramethyl-4-oxopiperidine-1-oxyl (pDT) in squalane, a viscous alkane, paying special attention to lower temperatures and lower concentrations, were carried out in an attempt to focus on DD, the lesser understood of the two interactions. Theoretically, the analysis has been extended to include the recent comprehensive treatment by Salikhov (Appl. Magn. Reson. 2010, 38, 237). In dilute solutions, both interactions (1) introduce a dispersion component, (2) broaden the lines, and (3) shift the lines. DD introduces a dispersion component proportional to the concentration and of opposite sign to that of HSE. Equations relating the EPR spectral parameters to the rate constants due to HSE and DD have been derived. By employing nonlinear least-squares fitting of theoretical spectra to a simple analytical function and the proposed equations, the contributions of the two interactions to items 1-3 may be quantified and compared with the same parameters obtained by fitting experimental spectra. This comparison supports the theory in its broad predictions; however, at low temperatures, the DD contribution to the experimental dispersion amplitude does not increase linearly with concentration. We are unable to deduce whether this discrepancy is due to inadequate analysis of the experimental data or an incomplete theory. A new key aspect of the more comprehensive theory is that there is enough information in the experimental spectra to find items 1-3 due to both interactions; however, in principle, appeal must be made to a model of molecular diffusion to separate the two. The permanent diffusion model is used to

  20. Identification of phenylbutyrate-generated metabolites in Huntington disease patients using parallel liquid chromatography/electrochemical array/mass spectrometry and off-line tandem mass spectrometry.

    Science.gov (United States)

    Ebbel, Erika N; Leymarie, Nancy; Schiavo, Susan; Sharma, Swati; Gevorkian, Sona; Hersch, Steven; Matson, Wayne R; Costello, Catherine E

    2010-04-15

    Oral sodium phenylbutyrate (SPB) is currently under investigation as a histone deacetylation (HDAC) inhibitor in Huntington disease (HD). Ongoing studies indicate that symptoms related to HD genetic abnormalities decrease with SPB therapy. In a recently reported safety and tolerability study of SPB in HD, we analyzed overall chromatographic patterns from a method that employs gradient liquid chromatography with series electrochemical array, ultraviolet (UV), and fluorescence (LCECA/UV/F) for measuring SPB and its metabolite phenylacetate (PA). We found that plasma and urine from SPB-treated patients yielded individual-specific patterns of approximately 20 metabolites that may provide a means for the selection of subjects for extended trials of SPB. The structural identification of these metabolites is of critical importance because their characterization will facilitate understanding the mechanisms of drug action and possible side effects. We have now developed an iterative process with LCECA, parallel LCECA/LCMS, and high-performance tandem MS for metabolite characterization. Here we report the details of this method and its use for identification of 10 plasma and urinary metabolites in treated subjects, including indole species in urine that are not themselves metabolites of SPB. Thus, this approach contributes to understanding metabolic pathways that differ among HD patients being treated with SPB. Copyright 2010 Elsevier Inc. All rights reserved.

  1. On-line high-performance liquid chromatography-ultraviolet-nuclear magnetic resonance method of the markers of nerve agents for verification of the Chemical Weapons Convention.

    Science.gov (United States)

    Mazumder, Avik; Gupta, Hemendra K; Garg, Prabhat; Jain, Rajeev; Dubey, Devendra K

    2009-07-03

    This paper details an on-flow liquid chromatography-ultraviolet-nuclear magnetic resonance (LC-UV-NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC-UV-NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C(18), mobile phase methanol:water 78:22 (v/v), UV detection at 268nm and (1)H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within +/-1.1%, while lower limit of detection upto 16mug (in mug absolute) for the NMR detector. Finally the developed LC-UV-NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time approximately 2h), sensitive, rugged and efficient.

  2. Characterization of phenolic compounds in Helichrysum melaleucum by high-performance liquid chromatography with on-line ultraviolet and mass spectrometry detection.

    Science.gov (United States)

    Gouveia, Sandra C; Castilho, Paula C

    2010-07-15

    Helicrysum melaleucum is a medicinal plant traditionally used in the islands of the Macaronesia region for the treatment of respiratory diseases. In this work, the phenolic compounds of Helicrysum melaleucum plants collected in different geographical locations of Madeira Island and their morphological parts (total aerial parts, leaves, flowers and stems) were extracted and analyzed separately by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-DAD/ESI-MS(n)). A total of 68 compounds were characterized based mainly on their UV and mass spectra. These included derivatives of O-glycosylated flavonoids (flavonol and flavones type), quinic acid, caffeic acid, lignans and polyphenols. The flowers were found to be the morphological part with higher variety of phenolic compounds. The large differences in the phenolic composition of plants collected from different geographical locations allowed the identification of a few components, such as pinoresinol and methoxylated flavone derivatives, likely to be useful as geographical markers. Also, these results promote further comparison of the bioactivities of the different samples analyzed. This paper marks the first report on the chemical analysis of Helichrysum melaleucum species. Copyright 2010 John Wiley & Sons, Ltd.

  3. Molecular-level characterization of crude oil compounds combining reversed-phase high-performance liquid chromatography with off-line high-resolution mass spectrometry

    Science.gov (United States)

    Sim, Arum; Cho, Yunju; Kim, Daae; Witt, Matthias; Birdwell, Justin E.; Kim, Byung Ju; Kim, Sunghwan

    2014-01-01

    A reversed-phase separation technique was developed in a previous study (Loegel et al., 2012) and successfully applied to the de-asphalted fraction of crude oil. However, to the best of our knowledge, the molecular-level characterization of oil fractions obtained by reversed-phase high-performance liquid chromatography (HPLC) coupled with high-resolution mass spectrometry (MS) has not yet been reported. A detailed characterization of the oil fractions prepared by reversed-phase HPLC was performed in this study. HPLC fractionation was carried out on conventional crude oil and an oil shale pyrolysate. The analyses of the fractions showed that the carbon number of alkyl chains and the double bond equivalent (DBE) value were the major factors determining elution order. The compounds with larger DBE (presumably more condensed aromatic structures) and smaller carbon number (presumably compounds with short side chains) were eluted earlier but those compounds with lower DBE values (presumably less aromatic structures) and higher carbon number (presumably compounds with longer alkyl chains) eluted later in the chromatograms. This separation behavior is in good agreement with that expected from the principles of reversed-phase separation. The data presented in this study show that reversed-phase chromatography is effective in separating crude oil compounds and can be combined with ultrahigh-resolution MS data to better understand natural oils and oil shale pyrolysates.

  4. Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

    Science.gov (United States)

    Roy, Robert J.; Wilson, Mark E.; Diderich, Greg S.; Steele, John W.

    2011-01-01

    The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell concentration overpotential resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid-cathode feed water electrolysis cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

  5. Optimized determination method for trans-10-hydroxy-2-decenoic acid content in royal jelly by high-performance liquid chromatography with an internal standard.

    Science.gov (United States)

    Zhou, Jinhui; Xue, Xiaofeng; Li, Yi; Zhang, Jinzhen; Zhao, Jing

    2007-01-01

    An optimized reversed-phase high-performance liquid chromatography method was developed to detect the trans-10-hydroxy-2-decenoic acid (10-HDA) content in royal jelly cream and lyophilized powder. The sample was extracted using absolute ethanol. Chromatographic separation of 10-HDA and methyl 4-hydroxybenzoate as the internal standard was performed on a Nova-pak C18 column. The average recoveries were 95.0-99.2% (n = 5) with relative standard deviation (RSD) values of 1.3-2.1% for royal jelly cream and 98.0-100.0% (n = 5) with RSD values of 1.6-3.0% for lyophilized powder, respectively. The limits of detection and quantitation were 0.5 and 1.5 mg/kg, respectively, for both royal jelly cream and lyophilized powder. The method was validated for the determination of practical royal jelly products. The concentration of 10-HDA ranged from 1.26 to 2.21% for pure royal jelly cream samples and 3.01 to 6.19% for royal jelly lyophilized powder samples. For 30 royal jelly products, the 10-HDA content varied from not detectable to 0.98%.

  6. On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry for the analysis of cyanotoxins in algal blooms.

    Science.gov (United States)

    Fayad, Paul B; Roy-Lachapelle, Audrey; Duy, Sung Vo; Prévost, Michèle; Sauvé, Sébastien

    2015-12-15

    An analytical method based on on-line SPE-LC-HESI-MS/MS has been developed for the detection and quantification of eight selected cyanotoxins in algal bloom waters that include mycrocystins, anatoxin-a and cylindrospermopsin. The injection volume was 2 mL according to the expected concentration of cyanotoxins in matrix. The method provides an analysis time of 7 min per sample, acceptable recovery values (91-101%), good precision (RSD cyanotoxins. All of the targeted cyanotoxins were detected with the exception of cylindrospermopsin. In addition, it was found that total microcystin concentrations in several surface water samples exceeded the proposed guidelines established by the province of Québec in Canada of 1.5 μg L(-1) as well as the World Health Organization of 1 μg L(-1) for both free and cell-bound microcystin-LR equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Epoxidized soy bean oil migrating from the gaskets of lids into food packed in glass jars. Analysis by on-line liquid chromatography-gas chromatography.

    Science.gov (United States)

    Fankhauser-Noti, Anja; Fiselier, Katell; Biedermann-Brem, Sandra; Grob, Koni

    2005-08-05

    The migration of epoxidized soy bean oil (ESBO) from the gasket in the lids of glass jars into foods, particularly those rich in edible oil, often far exceeds the legal limit (60 mg/kg). ESBO was determined through a methyl ester isomer of diepoxy linoleic acid. Transesterification occurred directly in the homogenized food. From the extracted methyl esters, the diepoxy components were isolated by normal-phase LC and transferred on-line to gas chromatography with flame ionization detection using the on-column interface in the concurrent solvent evaporation mode. The method involves verification elements to ensure the reliability of the results for every sample analyzed. The detection limit is 2-5 mg/kg, depending on the food. Uncertainty of the procedure is below 10%.

  8. Simultaneous determination of 1- and 2-naphthol in human urine using on-line clean-up column-switching liquid chromatography-fluorescence detection.

    Science.gov (United States)

    Preuss, Ralf; Angerer, Jürgen

    2004-03-05

    We developed a new 3-D HPLC method for on-line clean-up and simultaneous quantification of two important naphthalene metabolites, 1-naphthol and 2-naphthol, in human urine. Except an enzymatic hydrolysis no further sample pre-treatment is necessary. The metabolites are stripped from urinary matrix by on-line extraction on a restricted access material pre-column (RAM RP-8), transferred in backflush mode onto a silica-based CN-(cyano)phase column for further purification from interfering substances. By another successive column switching step both analytes are transferred with a minimum of overlapping interferences onto a C12 bonded reversed phase column with trimethylsilyl endcapping where the final separation is carried out. The entire arrangement is software controlled. Eluting analytes are quantified by fluorescence detection (227/430 nm) after an external calibration. Within a total run time of 40 min we can selectively quantify both naphthols with detection limits in the lower ppb range (1.5 and 0.5 microg/l for 1- and 2-naphthol, respectively) with excellent reliability (ensured by precision, accuracy, matrix-independency and FIOH quality assurance program participation). First results on a collective of 53 occupationally non exposed subjects showed mean levels of 11.0 microg/l (1-naphthol) and 12.9 microg/l (2-naphthol). Among smokers (n=21) a significantly elevated mean level of urinary naphthols was determined (1-naphthol: 19.2 microg/l and 2-naphthol: 23.7 microg/l) in comparison to non smokers (n=32; 1-naphthol: 5.6 microg/l, 2-naphthol: 5.6 microg/l).

  9. The impact of an international initiative on exposures to liquid laundry detergent capsules reported to the United Kingdom National Poisons Information Service between 2008 and 2015.

    Science.gov (United States)

    Day, Rachael; Eddleston, Michael; Thomas, Simon H L; Thompson, John P; Vale, J Allister

    2017-03-01

    Although the majority of those exposed to liquid laundry detergent capsules remain asymptomatic or suffer only minor clinical features after exposure, a small proportion develop central nervous system depression, stridor, pulmonary aspiration and/or airway burns following ingestion or conjunctivitis and corneal ulceration following eye exposure. As a consequence, the International Association for Soaps, Detergents and Maintenance Products (AISE) established a Product Stewardship Programme in Europe, requiring that safety measures be implemented to reduce the visibility of, and restrict access to, these detergent capsules by small children. Implementation occurred in the United Kingdom over several months during the first half of 2013. This study investigated whether the AISE Programme had an impact on the number and severity of exposures reported to the United Kingdom National Poisons Information Service. Telephone enquiries to the National Poisons Information Service relating to liquid laundry detergent capsules were analysed for the period January 2008 to December 2015. While there was a significant difference (p = 0.0002) between the mean number of annual exposures (469.4) reported between 2008 and 2012 and the mean number reported between 2014 and 2015 (403.5), the number of exposures was decreasing steadily prior to implementation of the Programme in 2013, which did not impact this fall from 2013 onwards. In addition, the number of exposures per million units sold was not impacted by the Programme. There was no significant difference (p = 0.68) between the mean number of exposures (11.8) with PSS ≥2 reported between 2008 and 2012 and the mean number (13.0) reported between 2014 and 2015. Although there was a 28.7% decrease between 2010-2012 and 2014-2015 in the number of exposures with PSS ≥2 per million units sold, this decrease was not statistically significant (p = 0.18). There is no evidence that the Product Stewardship Programme had a

  10. Potential of capillary-column-switching liquid chromatography-tandem mass spectrometry for the quantitative trace analysis of small molecules. Application to the on-line screening of drugs in water.

    Science.gov (United States)

    Pitarch, Elena; Hernandez, Felix; ten Hove, Jan; Meiring, Hugo; Niesing, Willem; Dijkman, Ellen; Stolker, Linda; Hogendoorn, Elbert

    2004-03-26

    We have investigated the potential of capillary-column-switching liquid chromatography coupled to tandem mass spectrometry (cLC-MS-MS) for the quantitative on-line trace analysis of target compounds in aqueous solutions. The technical design of the nano-scale cLC system developed at our Institute for peptide and protein identification has been tested and evaluated for the direct trace analysis of drugs in water samples. Sulphametoxazole, bezafibrate, metoprolol, carbamazepine and bisoprolol occurring frequently in Dutch waters, were selected as test compounds. Adequate conditions for trapping, elution and MS-MS detection were investigated by employing laboratory made 200 microm i.d. capillary columns packed with 5 microm aqua C18 material. In the final cLC-MS-MS conditions, a 1 cm length trapping column and a 4 cm length analytical column were selected. Under these conditions, the target compounds could be directly determined in water down to a level of around 50 ng/l employing only 25 microl of water sample. Validation was done by recovery experiments in ground-, surface- and drinking-water matrices as well as by the analysis of water samples with incurred residues and previously analyzed with a conventional procedure involving off-line solid-phase extraction and narrow-bore LC with MS-MS detection. The new methodology provided recoveries (50-500 ng/l level) between 50 and 114% with RSDs (n = 3, each level) below 20% for most of the compounds. Despite the somewhat less analytical performance in comparison to the conventional procedure, the on-line approach of the new methodology is very suitable for screening of drugs in aqueous samples.

  11. [Comparative analysis of 3D data visibility of the prepared tooth finishing line on a synthetic jaw model, captured by international scanners in a laboratory conditions].

    Science.gov (United States)

    Ryakhovskiy, A N; Kostyukova, V V

    The aim of the study was to compare accuracy of digital impression's finishing line and the zone under it taken by different intraoral scanning systems. Parameters of comparison were: different level of the finishing line to the gingiva and width of sulcus after retraction. For this purpose two synthetic jaw models with prepared teeth were scanned using intraoral scanning systems: 3D Progress (MHT S.P.A., IT - MHT Optic Research AG, CH); True Definition (3M ESPE, USA); Trios (3Shape A/S, DNK); CEREC AC Bluecam, CEREC Omnicam (Sirona Dental System GmbH, DE); Planscan (Planmeca, FIN) (each n=10). Reference-scanning was done by ATOS Core (GOM mbH, DE). The resulting digital impressions were superimposed with the master-scan. The lowest measured deviations (trueness) for intraoral scanners, where the finishing line was 0.5 mm above gingiva were with scanner True Definition - 18.8±6.63 (on the finishing line) and 51.0±14.33 µm (0.3 mm under the finishing line). In conditions where finishing line was on the same level with gingiva, scanner Trios showed the best results: 17.0±3.96 and 52.7±6.52 µm. When the finishing line was 0.5 mm under gingiva, none of the testing scanners could visualize the zone 0.3 mm lower the finishing line. The best results for accuracy o the finishing line in that circumstances showed Trios: 15.1±5.05 µm. The optimum visualization of the finishing line and the zone under it was reached when the sulcus was 0.3 mm after retraction. Thus, the best accuracy was obtained with Trios: 10.3±2.69 (on the finishing line) and 57.2±13.58 µm (0.3 mm under finishing line). The results show that intraoral scanners also provide enough accuracy for indicating finishing line and the zone under it in different conditions of preparation and gingiva retraction. However, not all of the testing scanners can properly indicate finishing line and the zone under it when shoulder is below gingiva and the width of sulcus is less than 0.2 mm.

  12. Per- and polyfluoroalkyl substances and fluorinated alternatives in urine and serum by on-line solid phase extraction-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kato, Kayoko; Kalathil, Akil A; Patel, Ayesha M; Ye, Xiaoyun; Calafat, Antonia M

    2018-06-14

    Per- and polyfluoroalkyl substances (PFAS), man-made chemicals with variable length carbon chains containing the perfluoroalkyl moiety (C n F 2n+1 -), are used in many commercial applications. Since 1999-2000, several long-chain PFAS, including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), have been detected at trace levels in the blood of most participants of the National Health and Nutrition Examination Survey (NHANES)-representative samples of the U.S. general population-while short-chain PFAS have not. Lower detection frequencies and concentration ranges may reflect lower exposure to short-chain PFAS than to PFOS or PFOA or that, in humans, short-chain PFAS efficiently eliminate in urine. We developed on-line solid phase extraction-HPLC-isotope dilution-MS/MS methods for the quantification in 50 μL of urine or serum of 15 C 3 -C 11 PFAS (C 3 only in urine), and three fluorinated alternatives used as PFOA or PFOS replacements: GenX (ammonium salt of 2,3,3,3,-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoate, also known as HFPO-DA), ADONA (ammonium salt of 4,8-dioxa-3H-perfluorononanoate), and 9Cl-PF3ONS (9-chlorohexadecafluoro-3-oxanonane-1-sulfonate), main component of F53-B. Limit of detection for all analytes was 0.1 ng/mL. To validate the method, we analyzed 50 commercial urine/serum paired samples collected in 2016 from U.S. volunteers with no known exposure to the chemicals. In serum, detection frequency and concentration patterns agreed well with those from NHANES. By contrast, except for perfluorobutanoate, we did not detect long-chain or short-chain PFAS in urine. Also, we did not detect fluorinated alternatives in either urine or serum. Together, these results suggest limited exposure to both short-chain PFAS and select fluorinated alternatives in this convenience population. Copyright © 2018. Published by Elsevier Ltd.

  13. Biodegradation of 2,4,6-trichlorophenol in a packed-bed biofilm reactor equipped with an internal net draft tube riser for aeration and liquid circulation

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-De Jesus, A.; Romano-Baez, F.J.; Leyva-Amezcua, L.; Juarez-Ramirez, C.; Ruiz-Ordaz, N. [Departamento de Ingenieria Bioquimica, Escuela Nacional de Ciencias Biologicas, IPN. Prol. Carpio y Plan de Ayala, Colonia Santo Tomas, s/n. CP 11340, Mexico, D.F. (Mexico); Galindez-Mayer, J. [Departamento de Ingenieria Bioquimica, Escuela Nacional de Ciencias Biologicas, IPN. Prol. Carpio y Plan de Ayala, Colonia Santo Tomas, s/n. CP 11340, Mexico, D.F. (Mexico)], E-mail: cmayer@encb.ipn.mx

    2009-01-30

    For the aerobic biodegradation of the fungicide and defoliant 2,4,6-trichlorophenol (2,4,6-TCP), a bench-scale packed-bed bioreactor equipped with a net draft tube riser for liquid circulation and oxygenation (PB-ALR) was constructed. To obtain a high packed-bed volume relative to the whole bioreactor volume, a high A{sub D}/A{sub R} ratio was used. Reactor's downcomer was packed with a porous support of volcanic stone fragments. PB-ALR hydrodynamics and oxygen mass transfer behavior was evaluated and compared to the observed behavior of the unpacked reactor operating as an internal airlift reactor (ALR). Overall gas holdup values {epsilon}{sub G}, and zonal oxygen mass transfer coefficients determined at various airflow rates in the PB-ALR, were higher than those obtained with the ALR. When comparing mixing time values obtained in both cases, a slight increment in mixing time was observed when reactor was operated as a PB-ALR. By using a mixed microbial community, the biofilm reactor was used to evaluate the aerobic biodegradation of 2,4,6-TCP. Three bacterial strains identified as Burkholderia sp., Burkholderia kururiensis and Stenotrophomonas sp. constituted the microbial consortium able to cometabolically degrade the 2,4,6-TCP, using phenol as primary substrate. This consortium removed 100% of phenol and near 99% of 2,4,6-TCP. Mineralization and dehalogenation of 2,4,6-TCP was evidenced by high COD removal efficiencies ({approx}95%), and by the stoichiometric release of chloride ions from the halogenated compound ({approx}80%). Finally, it was observed that the microbial consortium was also capable to metabolize 2,4,6-TCP without phenol as primary substrate, with high removal efficiencies (near 100% for 2,4,6-TCP, 92% for COD and 88% for chloride ions)

  14. Dehydroepiandrosterone sulfate quantification in serum using high-performance liquid chromatography/mass spectrometry and a deuterated internal standard: a technique suitable for routine use or as a reference method

    International Nuclear Information System (INIS)

    Shackleton, C.H.; Kletke, C.; Wudy, S.; Pratt, J.H.

    1990-01-01

    A thermospray high-performance liquid chromatography/mass spectrometry method for determination of serum dehydroepiandrosterone sulfate is described. The steroid was measured intact using [7,7-2H2]dehydroepiandrosterone sulfate as internal standard. The analysis was carried out in the negative ion mode by determining the peak height ratio of the molecular anions of the analyte and internal standard. The method was used to determine the steroid in serum from 15 male and female normal adults and the following values were obtained: males, 272 +/- 45 micrograms/dl (range, 197 to 331 micrograms/dl) and females, 215 +/- 67 micrograms/dl (range, 107 to 347 micrograms/dl). In addition, dehydroepiandrosterone sulfate was measured by high-performance liquid chromatography/mass spectrometry and radioimmunoassay (a commercial kit) on 25 individuals of all age groups. There was strong correlation between the values obtained, but the radioimmunoassay values were generally double those obtained by high-performance liquid chromatography/mass spectrometry. Three other steroid sulfates, androsterone sulfate, epiandrosterone sulfate, and androst-5-ene-3 beta, 17 beta-diol sulfate, were also assayed. In males, these had mean values of 112, 44, and 13 micrograms/dl and, in females, they had mean values of 84, 25, and 6 micrograms/dl, respectively. Radioimmunoassay cross-reactivity measurement for these steroids (as reference compounds) showed that they were unlikely to contribute greatly to the discrepancy between radioimmunoassay and high-performance liquid chromatography/mass spectrometry values

  15. Quantum liquids get thin

    Science.gov (United States)

    Ferrier-Barbut, Igor; Pfau, Tilman

    2018-01-01

    A liquid exists when interactions that attract its constituent particles to each other are counterbalanced by a repulsion acting at higher densities. Other characteristics of liquids are short-range correlations and the existence of surface tension (1). Ultracold atom experiments provide a privileged platform with which to observe exotic states of matter, but the densities are far too low to obtain a conventional liquid because the atoms are too far apart to create repulsive forces arising from the Pauli exclusion principle of the atoms' internal electrons. The observation of quantum liquid droplets in an ultracold mixture of two quantum fluids is now reported on page 301 of this issue by Cabrera et al. (2) and a recent preprint by Semeghini et al. (3). Unlike conventional liquids, these liquids arise from a weak attraction and repulsive many-body correlations in the mixtures.

  16. Separation and analysis of phenolic acids from Salvia miltiorrhiza and its related preparations by off-line two-dimensional hydrophilic interaction chromatography×reversed-phase liquid chromatography coupled with ion trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Sun, Wanyang; Tong, Ling; Miao, Jingzhuo; Huang, Jingyi; Li, Dongxiang; Li, Yunfei; Xiao, Hongting; Sun, Henry; Bi, Kaishun

    2016-01-29

    Salvia miltiorrhiza (SM) is one of the most widely used Traditional Chinese Medicine. Active constituents of SM mainly contain hydrophilic phenolic acids (PAs) and lipophilic tanshinones. However, due to the existing of multiple ester bonds and unsaturated bonds in the structures, PAs have numerous chemical conversion products. Many of them are so low-abundant that hard to be separated using conventional methods. In this study, an off-line two-dimensional liquid chromatography (2D-LC) method was developed to separate PAs in SM and its related preparations. In the first dimension, samples were fractionated by hydrophilic interaction chromatography (HILIC) (Acchrom×Amide, 4.6×250mm, 5μm) mainly based on the hydrogen bonding effects. The fractions were then separated on reversed-phase liquid chromatography (RP-LC) (Acquity HSS T3, 2.1×50mm, 1.7μm) according to hydrophobicity. For the selective identification of PAs, diode array detector (DAD) and electrospray ionization tandem ion trap time-of-flight mass spectrometry (ESI-IT-TOF-MS) were employed. Practical and effective peak capacities of all the samples were greater than 2046 and 1130, respectively, with the orthogonalities ranged from 69.7% to 92.8%, which indicated the high efficiency and versatility of this method. By utilizing the data post-processing techniques, including mass defect filter, neutral loss filter and product ion filter, a total of 265 compounds comprising 196 potentially new PAs were tentatively characterized. Twelve kinds of derivatives, mainly including glycosylated compounds, O-alkylated compounds, condensed compounds and hydrolyzed compounds, constituted the novelty of the newly identified PAs. The HILIC×RP-LC/TOF-MS system expanded our understanding on PAs of S. miltiorrhiza and its related preparations, which could also benefit the separation and characterization of polar constituents in complicated herbal extracts. Copyright © 2016. Published by Elsevier B.V.

  17. Separation and characterization of chemical constituents in Ginkgo biloba extract by off-line hydrophilic interaction×reversed-phase two-dimensional liquid chromatography coupled with quadrupole-time of flight mass spectrometry.

    Science.gov (United States)

    Ji, Shuai; He, Dan-Dan; Wang, Tian-Yun; Han, Jie; Li, Zheng; Du, Yan; Zou, Jia-Hui; Guo, Meng-Zhe; Tang, Dao-Quan

    2017-11-30

    Ginkgo biloba extract (GBE), derived from the leaves of Ginkgo biloba L., is one of the most widely used traditional Chinese medicines worldwide. Due to high structural diversity and low abundance of chemical constituents in GBE, conventional reversed-phase liquid chromatography has limited power to meet the needs of its quality control. In this study, an off-line hydrophilic interaction×reversed-phase two-dimensional liquid chromatography (HILIC×RP 2D-LC) system coupled with diode array detection (DAD) and quadrupole time-of-flight mass spectrometry (qTOF-MS) was established to comprehensively analyze the chemical constituents of GBE. After optimizing the chromatographic columns and mobile phase of 2D-LC, a Waters XBridge Amide column using acetonitrile/water/formic acid as the mobile phase was selected as the first dimension to fractionate GBE, and the obtained fractions were further separated on an Agilent Zorbax XDB-C18 column with methanol/water/formic acid as the mobile phase. As a result, a total of 125 compounds were detected in GBE. The orthogonality of the 2D-LC system was 69.5%, and the practical peak capacity was 3864 and 2994, respectively, calculated by two different methods. The structures of 104 compounds were tentatively characterized by qTOF-MS analysis, and 21 of them were further confirmed by comparing with reference standards. This established HILIC×RP 2D-LC-qTOF/MS system can greatly improve the separation and characterization of natural products in GBE or other complicated herbal extracts. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. XI International conference Problems of solvation and complex formation in solutions, and VI Conference of young scientists Theoretical and experimental chemistry of liquid-phase systems (Krestovsky readings). Summary of reports

    International Nuclear Information System (INIS)

    2011-01-01

    The collection contains materials of plenary, sectional and poster sessions, presented at the XI International conference Problems of solvation and complex formation in solutions, and VI Conference of young scientists Theoretical and experimental chemistry of liquid-phase systems (Krestovsky readings). Theoretical questions and new experimental methods of chemistry of solutions, structure and dynamics of molecular and ion-molecular systems in solution and at the phase boundary; modern aspects of applied chemistry of solutions are discussed [ru

  19. A High Temperature Liquid Plasma Model of the Sun

    Directory of Open Access Journals (Sweden)

    Robitaille P.-M.

    2007-01-01

    Full Text Available In this work, a liquid model of the Sun is presented wherein the entire solar mass is viewed as a high density/high energy plasma. This model challenges our current understanding of the densities associated with the internal layers of the Sun, advocating a relatively constant density, almost independent of radial position. The incompressible nature of liquids is advanced to prevent solar collapse from gravitational forces. The liquid plasma model of the Sun is a non-equilibrium approach, where nuclear reactions occur throughout the solar mass. The primary means of addressing internal heat transfer are convection and conduction. As a result of the convective processes on the solar surface, the liquid model brings into question the established temperature of the solar photosphere by highlighting a violation of Kirchhoff’s law of thermal emission. Along these lines, the model also emphasizes that radiative emission is a surface phenomenon. Evidence that the Sun is a high density/high energy plasma is based on our knowledge of Planckian thermal emission and condensed matter, including the existence of pressure ionization and liquid metallic hydrogen at high temperatures and pressures. Prior to introducing the liquid plasma model, the historic and scientific justifications for the gaseous model of the Sun are reviewed and the gaseous equations of state are also discussed.

  20. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Liquid chromatography-electrospray ionization tandem mass spectrometry for on-line characterization, monitoring and isotopic profiling of the main selenium-metabolite in human urine after consumption of Se-rich and Se-enriched food

    International Nuclear Information System (INIS)

    Dumont, Emmie; Ogra, Yasumitsu; Suzuki, Kazuo T.; Vanhaecke, Frank; Cornelis, Rita

    2006-01-01

    The metabolism of selenium (Se) in the human body has yet not completely been unravelled and hence, an efficient method for characterization and on-line monitoring of the main Se-compound in human urine after consumption of Se-rich food was developed. Total Se-concentration in human urine after consumption of several Se-rich products was measured with inductively coupled plasma mass spectrometry (ICP-MS). The highest Se concentration in urine was observed after 4-10 h. The urine samples were brought onto a reversed phase column and the Se was detected by ICP-MS. Parameters for liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) measurements were optimized by using commercially available sugars, because it is known that some of the urinary metabolites contain a sugar moiety. In order to characterize the predominant Se-metabolite, it was necessary to extensively clean-up the sample and preconcentrate the species. The main metabolite was measured on its precursor ion on three different m/z according to three isotopes of Se. Relative peak surfaces matched the relative abundances of the isotopes. The product ions could be measured in a human urine sample in accordance to the product ions of the commercially available sugars. Moreover, the evidence of a selenosugar was demonstrated by the use of the Se-isotopes when measuring the product ions. LC-ESI-MS-MS was proven to be very efficient for the characterization of the main urinary Se-metabolite and can be used for on-line monitoring of the compound in urine samples. The method can be extended for clinical screening after consumption of Se-(en)rich(ed) food by use of the Se-isotopic profile and/or of the typical product ions of (methyl)-N-acetyl-hexosamines

  2. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    Science.gov (United States)

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. International Illiquidity

    DEFF Research Database (Denmark)

    Malkhozov, Aytek; Mueller, Philippe; Vedolin, Andrea

    -predicted effect of funding conditions on asset prices internationally. Global illiquidity lowers the slope and increases the intercept of the international security market line. Local illiquidity helps explain the variation in alphas, Sharpe ratios, and the performance of betting-against-beta (BAB) strategies...

  4. Simple and quick determination of analgesics and other contaminants of emerging concern in environmental waters by on-line solid phase extraction coupled to liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido

    2016-05-13

    A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    Science.gov (United States)

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. Copyright 2009 Elsevier B.V. All rights reserved.

  6. Simultaneous quantification of eight bioactive components of Houttuynia cordata and related Saururaceae medicinal plants by on-line high performance liquid chromatography-diode array detector-electrospray mass spectrometry.

    Science.gov (United States)

    Meng, Jiang; Leung, Kelvin Sze-Yin; Dong, Xiao-Ping; Zhou, Yi-Sheng; Jiang, Zhi-Hong; Zhao, Zhong-Zhen

    2009-12-01

    An on-line high performance liquid chromatography (HPLC)-diode array detector (DAD)-electrospray ionization mass spectrometry (ESI-MS) method has been developed to quantify simultaneously eight bioactive chemical components in Houttuynia cordata Thunb and related Saururaceae medicinal plants. Simultaneous separation of these eight compounds was achieved on a C(18) analytical column with gradient elution of acetonitrile and 0.2% acetic acid (v/v) at a flow rate of 0.6 mL/min and being detected at 280 nm. These eight compounds were completely separated within 90 min. Good linear regression relationship (r(2)>0.9978) within test ranges was shown in all calibration curves. Good repeatabilty for the quantification of these eight compounds in H.cordata was also demonstrated in this method, with intra- and inter-day variations less than 3.0%. The method established was successfully applied to quantify eight bioactive compounds in closely related species of H.cordata, which provides a new basis for quality assessment of H.cordata.

  7. Microwave assisted saponification (MAS) followed by on-line liquid chromatography (LC)-gas chromatography (GC) for high-throughput and high-sensitivity determination of mineral oil in different cereal-based foodstuffs.

    Science.gov (United States)

    Moret, Sabrina; Scolaro, Marianna; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S

    2016-04-01

    A high throughput, high-sensitivity procedure, involving simultaneous microwave-assisted extraction (MAS) and unsaponifiable extraction, followed by on-line liquid chromatography (LC)-gas chromatography (GC), has been optimised for rapid and efficient extraction and analytical determination of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) in cereal-based products of different composition. MAS has the advantage of eliminating fat before LC-GC analysis, allowing an increase in the amount of sample extract injected, and hence in sensitivity. The proposed method gave practically quantitative recoveries and good repeatability. Among the different cereal-based products analysed (dry semolina and egg pasta, bread, biscuits, and cakes), egg pasta packed in direct contact with recycled paperboard had on average the highest total MOSH level (15.9 mg kg(-1)), followed by cakes (10.4 mg kg(-1)) and bread (7.5 mg kg(-1)). About 50% of the pasta and bread samples and 20% of the biscuits and cake samples had detectable MOAH amounts. The highest concentrations were found in an egg pasta in direct contact with recycled paperboard (3.6 mg kg(-1)) and in a milk bread (3.6 mg kg(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Determination of eugenol in rat plasma by liquid chromatography-quadrupole ion trap mass spectrometry using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Vachon, Pascal

    2006-11-01

    A rapid, selective and sensitive method was developed for the determination of eugenol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by full scan liquid chromatography electrospray quadrupole ion trap mass spectrometry (LC-ESI-QIT). The separation was achieved using a 100 x 2 mm C(8) analytical column combined with an isocratic mobile phase composed of 75:25 acetonitrile: 0.1% formic acid in water set at a flow rate of 0.25 mL/min. Signal intensity of the eugenol-dansyl chloride derivative was increased up to 100-fold as compared with the underivatized eugenol in positive electrospray mode. An analytical range of 100-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The LOD observed was 0.5 pg injected on column. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of eugenol. Copyright (c) 2006 John Wiley & Sons, Ltd.

  9. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Suzuki, Makoto; Nishiumi, Shin; Kobayashi, Takashi; Sakai, Arata; Iwata, Yosuke; Uchikata, Takato; Izumi, Yoshihiro; Azuma, Takeshi; Bamba, Takeshi; Yoshida, Masaru

    2017-05-30

    The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS. The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS. By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer. The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. PREFACE: Proceedings of the International Workshop on Current Challenges in Liquid and Glass Science, (The Cosener's House, Abingdon 10 12 January 2007)

    Science.gov (United States)

    Hannon, Alex C.; Salmon, Philip S.; Soper, Alan K.

    2007-10-01

    The workshop was held to discuss current experimental and theoretical challenges in liquid and glass science and to honour the contribution made by Spencer Howells (ISIS, UK) to the field of neutron scattering from liquids and glasses. The meeting was attended by 70 experimentalists, theorists and computer simulators from Europe, Japan and North America and comprised 34 oral presentations together with two lively poster sessions. Three major themes were discussed, namely (i) the glass transition and properties of liquids and glasses under extreme conditions; (ii) the complementarity of neutron and x-ray scattering techniques with other experimental methods; and (iii) the modelling of liquid and glass structure. These themes served to highlight (a) recent advances in neutron and x-ray instrumentation used to investigate liquid and glassy materials under extreme conditions; (b) the relationship between the results obtained from different experimental and theoretical/computational methods; and (c) the modern methods used to interpret experimental results. The presentations ranged from polyamorphism in liquids and glasses to protein folding in aqueous solution and included the dynamics of fresh and freeze-dried strawberries and red onions. The properties of liquid phosphorus were also memorably demonstrated! The formal highlight was the 'Spencerfest' dinner where Neil Cowlam (Sheffield, UK) gave an excellent after dinner speech. The organisation of the workshop benefited tremendously from the secretarial skills of Carole Denning (ISIS, UK). The financial support of the Council for the Central Laboratory of the Research Councils (CCLRC), the Liquids and Complex Fluids Group of the Institute of Physics, The ISIS Disordered Materials Group, the CCLRC Centre for Materials Physics and Chemistry and the CCLRC Centre for Molecular Structure and Dynamics is gratefully acknowledged. Finally, it is a pleasure to thank all the workshop participants whose lively contributions led

  11. Local Attitudes Towards AN International Project: a Study of Residents' Attitudes Towards a Future High Speed Rail Line in General and Towards Annoyance in Particular

    Science.gov (United States)

    Schaap, D.

    1996-05-01

    Plans for a high speed rail line in Holland generate concerns about the impact on the living environment. Residents living near the planned track have an extremely negative attitude towards the high speed rail line. Most of them do not see the need for the line and they expect a great deal of noise annoyance. There is a disparity between the expectations of the residents and those of the government: the residents expect much more noise that the government does, on the basis of scientific research. The image that residents have of the noise of a high speed train is probably too negative. Therefore the government should supply the residents with better and more detailed information about the noise and the possible annoyance. Furthermore, for a positive attitude, it is important that residents not only recognize the disadvantages of the rail line, but that they recognize some local advantages too. For instances, the government can guarantee compensation for the affected green space, or that other noise sources will be removed. Finally, the residents have the feeling they cannot influence the decision-making process. To reduce this feeling of powerlessness, the government can involve the residents; for example, in the decision-making about the local plans for the high speed rail line.

  12. Radioimmunotherapy for first-line and relapse treatment of aggressive B-cell non-Hodgkin lymphoma: an analysis of 215 patients registered in the international RIT-Network

    Energy Technology Data Exchange (ETDEWEB)

    Hohloch, Karin; Lankeit, H.K.; Truemper, L. [Georg August University, Hematology and Oncology, Goettingen (Germany); Zinzani, P.L. [University of Bologna, Institute of Hematology and Medical Oncology ' ' L. e A. Seragnoli' ' , Bologna (Italy); Scholz, C.W. [Charite, University Berlin, Hematology, Oncology and Tumor Immunology, Berlin (Germany); Lorsbach, M.; Windemuth-Kieselbach, C. [Alcedis GmbH, Giessen (Germany)

    2014-08-15

    Very few reliable clinical data about the use of radioimmunotherapy in aggressive B-cell lymphoma exist. Patients with aggressive B-cell lymphoma registered in the international RIT-Network were analysed with regard to prior treatment, response and side effects. The RIT-Network is a web-based registry that collects observational data from radioimmunotherapy-treated patients with malignant lymphoma across 13 countries. This analysis included 215 with aggressive B-cell lymphoma out of 232 patients registered in the RIT-Network. Histological subtypes were as follows: 190 diffuse large B-cell, 15 primary mediastinal, 9 anaplastic large cell, and 1 intravascular lymphoma. The median age of the patients was 62 years (range 17 - 88), with 27 % above the age of 70 years. Radioimmunotherapy was mainly used as consolidation after first-line or second-line chemotherapy (56.1 %), as part of third-line to eighth-line therapy for relapse (16.4 %), and in refractory disease (12.2 %). Grade IV neutropenia and thrombopenia and grade III anaemia were observed. The median time to recovery of blood count was 81 days (range 0 - 600 days). The overall response rate was 63.3 %. The complete response rate was 76.4 % in patients treated as part of first-line therapy, and 44.3 % in patients with relapse. Mean overall survival in first-line therapy patients was 32.7 months and 14.0 months in patients with relapse or refractory disease, respectively. Most patients with aggressive B-cell lymphoma in the RIT-Network received radioimmunotherapy as consolidation after first-line therapy with excellent complete remission and overall survival rates compared to published data. In relapsed aggressive B-cell lymphoma, radioimmunotherapy is a safe and feasible treatment leading to satisfactory response rates with acceptable toxicity. (orig.)

  13. Efficiency analysis on the use of internal lining in the Bolivia-Brazil gas pipeline; Analise da eficiencia do uso de revestimento interno na tubulacao do gasoduto Bolivia-Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil); Silva, Marcos Jose Moraes da [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Bittencourt, Maria Angelica Santos; Coelho Junior, Robson Teixeira [TBG - Transportadora Brasileira Gasoduto Bolivia Brasil S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    The internal lining in gas pipelines aims the reduction of roughness and, consequently, the friction factor, therefore resulting in a reduction of pressure drop in natural gas flowing. During Bolivia-Brazil gas pipeline basic design, the cost benefit of internal coating was analyzed, in terms of friction factor reduction and distances between Compressor Stations. It was observed an increase of transport capacity and reduction of compressors' power, thus leading to its utilization. Since the pipeline is already in operation, using a SCADA system with Advanced Functions, a comparison between the current real friction factor in the pipeline with that theoretical values used during the design phase becomes possible. Through this comparison, it is possible to evaluate internal coating's efficiency, quantifying its real benefit for gas pipelines. (author)

  14. Microorganism mediated liquid fuels

    Energy Technology Data Exchange (ETDEWEB)

    Troiano, Richard

    2018-03-20

    Herein disclosed is a method for producing liquid hydrocarbon product, the method comprising disintegrating a hydrocarbon source; pretreating the disintegrated hydrocarbon source; solubilizing the disintegrated hydrocarbon source to form a slurry comprising a reactant molecule of the hydrocarbon source; admixing a biochemical liquor into the slurry, wherein the biochemical liquor comprises at least one conversion enzyme configured to facilitate bond selective photo-fragmentation of said reactant molecule of the hydrocarbon source, to form liquid hydrocarbons via enzyme assisted bond selective photo-fragmentation, wherein said conversion enzyme comprises reactive sites configured to restrict said reactant molecule such that photo-fragmentation favorably targets a preselected internal bond of said reactant molecule; separating the liquid hydrocarbons from the slurry, wherein contaminants remain in the slurry; and enriching the liquid hydrocarbons to form a liquid hydrocarbon product. Various aspects of such method/process are also discussed.

  15. Market liquidity and financial stability.

    OpenAIRE

    Crockett, A.

    2008-01-01

    Stability in financial institutions and in financial markets are closely intertwined. Banks and other financial institutions need liquid markets through which to conduct risk management. And markets need the back-up liquidity lines provided by financial institutions. Market liquidity depends not only on objective, exogenous factors, but also on endogenous market dynamics. Central banks responsible for systemic stability need to consider how far their traditional responsibility for the health ...

  16. Argon solubility in liquid steel

    NARCIS (Netherlands)

    Boom, R; Dankert, O; Van Veen, A; Kamperman, AA

    2000-01-01

    Experiments have been performed to establish the solubility of argon in liquid interstitial-free steel. The solubility appears to be lower than 0.1 at ppb, The results are in line with argon solubilities reported in the literature on liquid iron. Semiempirical theories and calculations based on the

  17. Swivel Joint For Liquid Nitrogen

    Science.gov (United States)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  18. Anakinra as first-line disease-modifying therapy in systemic juvenile idiopathic arthritis: report of forty-six patients from an international multicenter series

    NARCIS (Netherlands)

    Nigrovic, Peter A.; Mannion, Melissa; Prince, Femke H. M.; Zeft, Andrew; Rabinovich, C. Egla; van Rossum, Marion A. J.; Cortis, Elisabetta; Pardeo, Manuela; Miettunen, Paivi M.; Janow, Ginger; Birmingham, James; Eggebeen, Aaron; Janssen, Erin; Shulman, Andrew I.; Son, Mary Beth; Hong, Sandy; Jones, Karla; Ilowite, Norman T.; Cron, Randy Q.; Higgins, Gloria C.

    2011-01-01

    To examine the safety and efficacy of the interleukin-1 (IL-1) receptor antagonist anakinra as first-line therapy for systemic juvenile idiopathic arthritis (JIA). Patients with systemic JIA receiving anakinra as part of initial disease-modifying antirheumatic drug (DMARD) therapy were identified

  19. Mutational Correlates of Virological Failure in Individuals Receiving a WHO-Recommended Tenofovir-Containing First-Line Regimen: An International Collaboration

    Directory of Open Access Journals (Sweden)

    Soo-Yon Rhee

    2017-04-01

    Full Text Available Tenofovir disoproxil fumarate (TDF genotypic resistance defined by K65R/N and/or K70E/Q/G occurs in 20% to 60% of individuals with virological failure (VF on a WHO-recommended TDF-containing first-line regimen. However, the full spectrum of reverse transcriptase (RT mutations selected in individuals with VF on such a regimen is not known. To identify TDF regimen-associated mutations (TRAMs, we compared the proportion of each RT mutation in 2873 individuals with VF on a WHO-recommended first-line TDF-containing regimen to its proportion in a cohort of 50,803 antiretroviral-naïve individuals. To identify TRAMs specifically associated with TDF-selection pressure, we compared the proportion of each TRAM to its proportion in a cohort of 5805 individuals with VF on a first-line thymidine analog-containing regimen. We identified 83 TRAMs including 33 NRTI-associated, 40 NNRTI-associated, and 10 uncommon mutations of uncertain provenance. Of the 33 NRTI-associated TRAMs, 12 – A62V, K65R/N, S68G/N/D, K70E/Q/T, L74I, V75L, and Y115F – were more common among individuals receiving a first-line TDF-containing compared to a first-line thymidine analog-containing regimen. These 12 TDF-selected TRAMs will be important for monitoring TDF-associated transmitted drug-resistance and for determining the extent of reduced TDF susceptibility in individuals with VF on a TDF-containing regimen.

  20. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  1. Equation of state of liquid Indium under high pressure

    Directory of Open Access Journals (Sweden)

    Huaming Li

    2015-09-01

    Full Text Available We apply an equation of state of a power law form to liquid Indium to study its thermodynamic properties under high temperature and high pressure. Molar volume of molten indium is calculated along the isothermal line at 710K within good precision as compared with the experimental data in an externally heated diamond anvil cell. Bulk modulus, thermal expansion and internal pressure are obtained for isothermal compression. Other thermodynamic properties are also calculated along the fitted high pressure melting line. While our results suggest that the power law form may be a better choice for the equation of state of liquids, these detailed predictions are yet to be confirmed by further experiment.

  2. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  3. An on-spot internal standard addition approach for accurately determining colistin A and colistin B in dried blood spots using ultra high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung

    2017-10-25

    Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Moving droplets : The measurement of contact lines

    NARCIS (Netherlands)

    Poelma, C.; Franken, M.J.Z.; Kim, H.; Westerweel, J.

    2014-01-01

    Contact lines are the locations where a gas, liquid and a solid meet. From everyday experience we know that such contact lines can be mobile, for example in the case of a water droplet sliding over a glass surface. However, the continuum description of the flow towards or away from a contact line

  5. An Asian poverty line? Issues and options

    OpenAIRE

    Klasen, Stephan

    2016-01-01

    Given Asia's record of rapid economic growth and the conceptual and empirical problems of the current international income poverty line ('dollar-a-day'), this paper discusses whether there is merit to develop an Asia-specific poverty line that addresses some of the shortcomings of the dollar-a-day line and additionally considers Asia's particular economic situation. We consider various ways of creating an Asia-specific poverty line, including an Asia-specific international income poverty line...

  6. Characterisation of the interaction between liquid film and flue gas flow at walls and internals in FGD scrubbers; Beschreibung der gegenseitigen Beeinflussung von Fluessigkeitsschicht und Rauchgasstroemung an Waenden und internen Einbauten in REA-Waeschern

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Mario [Technische Univ. Dortmund (Germany). Lehrstuhl Mechanische Verfahrenstechnik; Fahlenkamp, Hans

    2012-07-01

    The VGB Research Project 'Characterisation of the interaction between liquid film and flue gas flow at walls and internals in FGD scrubbers' covers the droplet wall interaction in flue gas scrubbers. In the context of optimised FGD design, especially in fulfilling the increasing requirements on the conventional flue gas treatment by the CCS design, a better understanding of the flow behaviour near the wall is crucial. Within the framework of the research project an experimental setup is designed, built up and run. (orig.)

  7. Development of an on-line solid phase extraction ultra-high-performance liquid chromatography technique coupled to tandem mass spectrometry for quantification of bisphenol S and bisphenol S glucuronide: Applicability to toxicokinetic investigations.

    Science.gov (United States)

    Grandin, Flore; Picard-Hagen, Nicole; Gayrard, Véronique; Puel, Sylvie; Viguié, Catherine; Toutain, Pierre-Louis; Debrauwer, Laurent; Lacroix, Marlène Z

    2017-12-01

    Regulatory measures and public concerns regarding bisphenol A (BPA) have led to its replacement by structural analogues, such as Bisphenol S (BPS), in consumer products. At present, no toxicokinetic investigations have been conducted to assess the factors determining human internal exposure to BPS for subsequent risk assessment. Toxicokinetic studies require reliable analytical methods to measure the plasma concentrations of BPS and its main conjugated metabolite, BPS-glucuronide (BPS-G). An efficient on-line SPE-UPLC-MS/MS method for the simultaneous quantification of BPS and BPS-G in ovine plasma was therefore developed and validated in accordance with the European Medicines Agency guidelines for bioanalytical method validation. This method has a limit of quantification of 3ngmL -1 for BPS and 10ngmL -1 for BPS-G, an analytical capacity of 200 samples per day, and is particularly well suited to toxicokinetic studies. Use of this method in toxicokinetic studies in sheep showed that BPS, like BPA, is efficiently metabolized into its glucuronide form. However, the clearances and distributions of BPS and BPS-G were lower than those of the corresponding unconjugated and glucuroconjugated forms of BPA. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A Cell Internalizing Antibody Targeting Capsid Protein (p24 Inhibits the Replication of HIV-1 in T Cells Lines and PBMCs: A Proof of Concept Study.

    Directory of Open Access Journals (Sweden)

    Syed A Ali

    Full Text Available There remains a need for newer therapeutic approaches to combat HIV/AIDS. Viral capsid protein p24 plays important roles in HIV pathogenesis. Peptides and small molecule inhibitors targeting p24 have shown to inhibit virus replication in treated cell. High specificity and biological stability of monoclonal antibodies (mAbs make them an attractive contender for in vivo treatments. However, mAbs do not enter into cells, thus are restricted to target surface molecules. This also makes targeting intracellular HIV-1 p24 a challenge. A mAb specific to p24 that can internalize into the HIV-infected cells is hypothesized to inhibit the virus replication. We selected a mAb that has previously shown to inhibit p24 polymerization in an in vitro assay and chemically conjugated it with cell penetrating peptides (CPP to generate cell internalizing anti-p24 mAbs. Out of 8 CPPs tested, κFGF-MTS -conjugated mAbs internalized T cells most efficiently. At nontoxic concentration, the κFGF-MTS-anti-p24-mAbs reduced the HIV-1 replication up to 73 and 49% in T-lymphocyte and PBMCs respectively. Marked inhibition of HIV-1 replication in relevant cells by κFGF-MTS-anti-p24-mAbs represents a viable strategy to target HIV proteins present inside the cells.

  9. Volatile liquid storage system

    International Nuclear Information System (INIS)

    Laverman, R.J.; Winters, P.J.; Rinehart, J.K.

    1992-01-01

    This patent describes a method of collecting and abating emission from a volatile liquid in an above ground storage tank. It comprises the liquid storage tank having a bottom, a vertical cylindrical circular wall having a lower edge portion joined to the bottom, and an external fixed roof, the tank having an internal floating roof floating on a volatile liquid stored in the tank, and air vent means in the tank in communication with a vapor space in the tank constituting at least the space above the floating roof when the floating roof floats on a predetermined maximum volume of volatile liquid in the tank; permitting ambient air; pumping emission laden air from the tank vapor space above the floating roof; and by means of the emissions abatement apparatus eliminating most of the emission from the emissions laden air with formation of a gaseous effluent and then discharging the resulting gaseous effluent to the atmosphere

  10. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  11. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-01-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  12. (Liquid + liquid), (solid + liquid), and (solid + liquid + liquid) equilibria of systems containing cyclic ether (tetrahydrofuran or 1,3-dioxolane), water, and a biological buffer MOPS

    International Nuclear Information System (INIS)

    Altway, Saidah; Taha, Mohamed; Lee, Ming-Jer

    2015-01-01

    Graphical abstract: - Highlights: • MOPS buffer induced liquid phase splitting for mixtures of water with THF or 1,3-dioxolane. • Phase boundaries of LLE, SLE, and SLLE were determined experimentally. • Tie-lines at LLE and at SLLE were also measured. • Phase diagrams of MOPS + water + THF or 1,3-dioxolane are prepared. • LLE tie-line data are correlated satisfactorily with the NRTL model. - Abstract: Two liquid phases were formed as the addition of a certain amount of biological buffer 3-(N-morpholino)propane sulfonic acid (MOPS) in the aqueous solutions of tetrahydrofuran (THF) or 1,3-dioxolane. To evaluate the feasibility of recovering the cyclic ethers from their aqueous solutions with the aid of MOPS, we determined experimentally the phase diagrams of the ternary systems of {cyclic ether (THF or 1,3-dioxolane) + water + MOPS} at T = 298.15 K under atmospheric pressure. In this study, the solubility data of MOPS in water and in the mixed solvents of water/cyclic ethers were obtained from the results of a series of density measurements, while the (liquid + liquid) and the (solid + liquid + liquid) phase boundaries were determined by visually inspection. Additionally, the tie-line results for (liquid + liquid) equilibrium (LLE) and for (solid + liquid + liquid) equilibrium (SLLE) were measured using an analytical method. The reliability of the experimental LLE tie-line results data was validated by using the Othmer–Tobias correlation. These LLE tie-line values were correlated well with the NRTL model. The phase diagrams obtained from this study reveal that MOPS is a feasible green auxiliary agent to recover the cyclic ethers from their aqueous solutions, especially for 1,3-dioxolane

  13. Analysis of nicotine and cotinine in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry as biomarkers of exposure to tobacco smoke.

    Science.gov (United States)

    Inukai, Takehito; Kaji, Sanae; Kataoka, Hiroyuki

    2018-07-15

    Smoking not only increases the risk of lung cancer but is strongly related to the onset of cardiovascular disease. Particularly, passive smoking due to sidestream smoke is a critical public health problem. To assess active and passive exposure to tobacco smoke, we developed a simple and sensitive method, consisting of on-line in-tube solid phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), to determine nicotine and its metabolite cotinine in hair samples. These compounds were separated within 5 min using a Polar-RP80A column and detected in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 capillary column as an extraction device. The extracted compounds in the stationary phase on the inner wall of the capillary could be dissolved easily into the mobile phase and transferred to an LC column. Using the in-tube SPME LC-MS/MS method, the calibration curves were linear in the 5-1000 pg/mL ranges for nicotine and cotinine, and the detection limits (signal to noise ratio of 3) were 0.45 and 0.13 pg/mL, respectively. The intra-day and inter-day precisions were below 3.4% and 6.0% (n = 5), respectively. This method was utilized successfully to analyze pg/mg levels of nicotine and cotinine in 1 mg of hairs without interference peaks, and good recoveries were obtained. The concentration of cotinine in hair was two orders of magnitude lower than that of nicotine, but a good positive correlation was found between the concentrations of these compounds. This method can automate the extraction, concentration and analysis of samples, and is useful for the assessment of long-term exposure to tobacco smoke. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. LIQUID CHROMATOGRAPHIC / MASS SPECTROMETRIC DETERMINATION OF MORPHINE, CODEINE AND COCAINE IN HUMAN SERA USING A NEW INTERNAL SURFACE REVERSED PHASE COLUMN

    OpenAIRE

    Hattori, Hideki; Arinobu, Tetsuya; Iwai, Masae; Suzuki, Osamu; Seno, Hiroshi

    2003-01-01

    A new internal surface reversed phase column (Shim-pack MAYI-ODS) was used for analysis of morphine, codeine and cocaine in human sera by LC/MS/MS. The column enabled direct injection of crude biological samples without pretreatment realizing a rapid analytical procedure. Therecoveries of morphine, codeine and cocaine spiked into human sera were 50-60 %. The regression equations for morphine, codeine and cocaine in sera, using atropine as internal standard, showed good linearity in the ranges...

  15. Technical committee meeting on Liquid Metal Fast Reactor (LMFR) developments. 33rd annual meeting of the International Working Group on Fast Reactors (IWG-FR). Working material

    International Nuclear Information System (INIS)

    2000-01-01

    Over the past 33 years, the IAEA has actively encouraged and advocated international cooperation in fast reactor technology. The present publication contains information on the status of fast reactor development and on worldwide activities in this advanced nuclear power technology during 1999/2000, as reported at the 33. annual meeting of the International Working Group on Fast Reactors. It is intended to provide information regarding the current status of LMFR development in IAEA Member States

  16. Dual-lifetime referencing (DLR: a powerful method for on-line measurement of internal pH in carrier-bound immobilized biocatalysts

    Directory of Open Access Journals (Sweden)

    Boniello Caterina

    2012-03-01

    Full Text Available Abstract Background Industrial-scale biocatalytic synthesis of fine chemicals occurs preferentially as continuous processes employing immobilized enzymes on insoluble porous carriers. Diffusional effects in these systems often create substrate and product concentration gradients between bulk liquid and the carrier. Moreover, some widely-used biotransformation processes induce changes in proton concentration. Unlike the bulk pH, which is usually controlled at a suitable value, the intraparticle pH of immobilized enzymes may deviate significantly from its activity and stability optima. The magnitude of the resulting pH gradient depends on the ratio of characteristic times for enzymatic reaction and on mass transfer (the latter is strongly influenced by geometrical features of the porous carrier. Design and selection of optimally performing enzyme immobilizates would therefore benefit largely from experimental studies of the intraparticle pH environment. Here, a simple and non-invasive method based on dual-lifetime referencing (DLR for pH determination in immobilized enzymes is introduced. The technique is applicable to other systems in which particles are kept in suspension by agitation. Results The DLR method employs fluorescein as pH-sensitive luminophore and Ru(II tris(4,7-diphenyl-1,10-phenantroline, abbreviated Ru(dpp, as the reference luminophore. Luminescence intensities of the two luminophores are converted into an overall phase shift suitable for pH determination in the range 5.0-8.0. Sepabeads EC-EP were labeled by physically incorporating lipophilic variants of the two luminophores into their polymeric matrix. These beads were employed as carriers for immobilization of cephalosporin C amidase (a model enzyme of industrial relevance. The luminophores did not interfere with the enzyme immobilization characteristics. Analytical intraparticle pH determination was optimized for sensitivity, reproducibility and signal stability under

  17. High Line

    DEFF Research Database (Denmark)

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  18. Proceedings of the Newfoundland Ocean Industries Association's 20. Annual International Petroleum Conference : East Coast Canada : Success in a challenging environment. On-line ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This conference organized by the Newfoundland Ocean Industries Association (NOIA) provided a forum for exchange on issues dealing with Canada's east coast offshore hydrocarbon resource development. It also promoted Newfoundland's international reputation for competence in ocean engineering and marine dynamics. The topics of discussion at this conference included updates on the development of Newfoundland's Grand Banks which includes the Terra Nova, Hibernia, White Rose, and the Hebron/Ben Nevis oil and gas fields. Several papers described new initiatives in the Atlantic offshore sector, including deep water challenges and opportunities. A session devoted to competitiveness and technology focused on reducing drilling costs and enhancing productivity. Regulatory and fiscal issues were also discussed along with the socio-economic impact that resource development can bring to Canada's east coast. The conference featured 22 presentations, of which 9 have been indexed separately for inclusion in this database. tabs., figs

  19. Short-term effects of ultrahigh concentration cationic silica nanoparticles on cell internalization, cytotoxicity, and cell integrity with human breast cancer cell line (MCF-7)

    Energy Technology Data Exchange (ETDEWEB)

    Seog, Ji Hyun [Korea Advanced Institute of Science and Technology, Graduate School of Nanoscience and Technology (Korea, Republic of); Kong, Bokyung [Corning Precision Materials (Korea, Republic of); Kim, Dongheun [Korea Advanced Institute of Science and Technology, Graduate School of Nanoscience and Technology (Korea, Republic of); Graham, Lauren M. [University of Maryland, Department of Chemistry and Biochemistry (United States); Choi, Joon Sig [Chungnam National University, Department of Biochemistry (Korea, Republic of); Lee, Sang Bok, E-mail: slee@umd.edu [Korea Advanced Institute of Science and Technology, Graduate School of Nanoscience and Technology (Korea, Republic of)

    2015-01-15

    High concentrations of cationic colloidal silica nanoparticles (CCS-NPs) have been widely used for the enrichment of plasma membrane proteins. However, the interaction between the CCS-NPs and cells under the required concentration for the isolation of plasma membrane are rarely investigated. We evaluated the internalization and toxicity of the 15 nm CCS-NPs which were exposed at high concentrations with short time in human breast cancer cells (MCF-7) with transmission electron microscopy, energy dispersive X-ray spectroscopy, inductively coupled plasma atomic emission spectroscopy, and colorimetric assays. The NPs were observed throughout the cells, particularly in the cytoplasm and the nucleus, after short incubation periods. Additionally, the NPs significantly influenced the membrane integrity of the MCF-7 cells.

  20. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  1. International Conference on Liquid and Amorphous Metals (5th) Held at Los Angeles, California on August 15-19, 1983. Abstract.

    Science.gov (United States)

    1983-08-19

    de Fisica, niquV ".X-rav,ni tron and .i ,, tron it irin v,.rcril.nt" Facultad de Ingenieria , Paseo Col6n 850, 1063 Argentina, and w.r, p.rfirmL-d ,n...it is important Results wi 1 be presented here on the thermal for the industrial application. In these glassy Rext of m esn am rpho te Prelaxation of...Sn-Se LIQUID ALLOY. D. sity, Daejon 300-31, Korea. H. Kurlat, Universidad de Buenos Aires, Facultad de Ingenieria , Buenos Aires, In order to

  2. World lines.

    OpenAIRE

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  3. The Widom line of supercooled water

    International Nuclear Information System (INIS)

    Franzese, Giancarlo; Stanley, H Eugene

    2007-01-01

    Water can be supercooled to temperatures as low as -92 deg. C, the experimental crystal homogeneous nucleation temperature T H at 2 kbar. Within the supercooled liquid phase its response functions show an anomalous increase consistent with the presence of a liquid-liquid critical point located in a region inaccessible to experiments on bulk water. Recent experiments on the dynamics of confined water show that a possible way to understand the properties of water is to investigate the supercooled phase diagram in the vicinity of the Widom line (locus of maximum correlation length) that emanates from the hypothesized liquid-liquid critical point. Here we explore the Widom line for a Hamiltonian model of water using an analytic approach, and discuss the plausibility of the hypothesized liquid-liquid critical point, as well as its possible consequences, on the basis of the assumptions of the model. The present analysis allows us (i) to find an analytic expression for the spinodal line of the high-density liquid phase, with respect to the low-density liquid phase, showing that this line becomes flat in the P-T phase diagram in the physical limit of a large number of available orientations for the hydrogen bonds, as recently seen in simulations and experiments (Xu et al 2005 Proc. Natl Acad. Sci. 102 16558); (ii) to find an estimate of the values for the hypothesized liquid-liquid critical point coordinates that compare very well with Monte Carlo results; and (iii) to show how the Widom line can be located by studying the derivative of the probability of forming hydrogen bonds with local tetrahedral orientation which can be calculated analytically within this approach

  4. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  5. Liquidity ratios. A structural and dynamic analysis, during 2006-2012, of the companies having the business line in industry and construction, listed and traded on the Bucharest Stock Exchange

    OpenAIRE

    Diana Elena VASIU; Nicolae BALTEȘ; Iulian Nicolae GHEORGHE

    2015-01-01

    Liquidity ratios are used to measure a company’s ability to pay short-term debt, assessing the amount of cash and cash equivalents that it has on the short term. Considering the companies listed on Bucharest Stock Exchange among the best performing, due to the high requirements imposed by a stock market, in this paper has been analyzed the way the financial crisis affected the liquidity of companies listed on BSE, acting in industry and construction domains.

  6. An inkjet-printed microfluidic device for liquid-liquid extraction.

    Science.gov (United States)

    Watanabe, Masashi

    2011-04-07

    A microfluidic device for liquid-liquid extraction was quickly produced using an office inkjet printer. An advantage of this method is that normal end users, who are not familiar with microfabrication, can produce their original microfluidic devices by themselves. In this method, the printer draws a line on a hydrophobic and oil repellent surface using hydrophilic ink. This line directs a fluid, such as water or xylene, to form a microchannel along the printed line. Using such channels, liquid-liquid extraction was successfully performed under concurrent and countercurrent flow conditions. © The Royal Society of Chemistry 2011

  7. Status of ACCULINNA beam line

    CERN Document Server

    Rodin, A M; Bogdanov, D D; Golovkov, M S; Fomichev, A S; Sidorchuk, S I; Slepnev, R S; Wolski, R; Ter-Akopian, G M; Oganessian, Yu T; Yukhimchuk, A A; Perevozchikov, V V; Vinogradov, Yu I; Grishenchkin, S K; Demin, A M; Zlatoustovskii, S V; Kuryakin, A V; Filchagin, S V; Ilkaev, R I

    2003-01-01

    The separator ACCULINNA was upgraded to achieve new experimental requirements. The beam line was extended by new ion-optical elements beyond the cyclotron hall. The new arrangements yield much better background conditions. The intensities of sup 6 He and sup 8 He radioactive beams produced in fragmentation of 35 A MeV sup 1 sup 1 B ions were increased up to a factor of 10. The upgraded beam line was used in experiments to study the sup 5 H resonance states populated in the t+t reaction. A cryogenic liquid tritium target was designed and installed at the separator beam line.

  8. Challenges Related to the Use of Liquid Metal and Molten Salt Coolants in Advanced Reactors. Report of the collaborative project COOL of the International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO)

    International Nuclear Information System (INIS)

    2013-05-01

    The International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO) was launched in 2000, based on a resolution by the IAEA General Conference (GC(44)/RES/21). INPRO aims at helping to ensure that nuclear energy is available in the twenty-first century in a sustainable manner, and seeks to bring together all interested Member States, both technology holders and technology users, to jointly consider actions to achieve desired innovations. INPRO is taking care of the specific needs of developing countries. One of the aims of INPRO is to develop options for enhanced sustainability through promotion of technical and institutional innovations in nuclear energy technology through collaborative projects among IAEA Member States. Collaboration among INPRO members is fostered on selected innovative nuclear technologies to bridge technology gaps. Collaborative projects have been selected so that they complement other national and international R and D activities. The INPRO Collaborative Project COOL on Investigation of Technological Challenges Related to the Removal of Heat by Liquid Metal and Molten Salt Coolants from Reactor Cores Operating at High Temperatures investigated the technological challenges of cooling reactor cores that operate at high temperatures in advanced fast reactors, high temperature reactors and accelerator driven systems by using liquid metals and molten salts as coolants. The project was initiated in 2008 and was led by India; experts from Brazil, China, Germany, India, Italy and the Republic of Korea participated and provided chapters of this report. The INPRO Collaborative Project COOL addressed the following fields of research regarding liquid metal and molten salt coolants: (i) survey of thermophysical properties; (ii) experimental investigations and computational fluid dynamics studies on thermohydraulics, specifically pressure drop and heat transfer under different operating conditions; (iii) monitoring and control of coolant

  9. Simultaneous Determination of Palladium and Platinum by On-line ...

    African Journals Online (AJOL)

    NJD

    using high performance liquid chromatography equipped with an on-line enrichment technique. Prior to ... The on-line enrichment system (Waters Corporation, USA) that was ... Using an appropriate volume (industrial plant effluents 20 mL,.

  10. Liquid Metal Engineering and Technology. Volume 1

    International Nuclear Information System (INIS)

    1988-01-01

    These proceedings of the fourth international conference on liquid metal engineering and technology volume 1, are devided into 3 sections bearing on: - Apparatus and components for liquid metal (29 papers) - Liquid metal leaks, fires and fumes (10 papers) - Cleaning, decontamination, waste disposal (14 papers) [fr

  11. Subsidizing Liquidity

    DEFF Research Database (Denmark)

    Malinova, Katya; Park, Andreas

    2015-01-01

    the breakdown of trading fees between liquidity demanders and suppliers matters. Posted quotes adjust after the change in fee composition, but the transaction costs for liquidity demanders remain unaffected once fees are taken into account. However, as posted bid-ask spreads decline, traders (particularly......Facing increased competition over the last decade, many stock exchanges changed their trading fees to maker-taker pricing, an incentive scheme that rewards liquidity suppliers and charges liquidity demanders. Using a change in trading fees on the Toronto Stock Exchange, we study whether and why...... retail) use aggressive orders more frequently, and adverse selection costs decrease....

  12. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  13. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  14. Silver linings.

    Science.gov (United States)

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Liquidity Runs

    NARCIS (Netherlands)

    Matta, R.; Perotti, E.

    2016-01-01

    Can the risk of losses upon premature liquidation produce bank runs? We show how a unique run equilibrium driven by asset liquidity risk arises even under minimal fundamental risk. To study the role of illiquidity we introduce realistic norms on bank default, such that mandatory stay is triggered

  16. Managing liquidity

    DEFF Research Database (Denmark)

    Pokutta, Sebastian; Schmaltz, Christian

    2011-01-01

    Large banking groups face the question of how to optimally allocate and generate liquidity: in a central liquidity hub or in many decentralized branches. We translate this question into a facility location problem under uncertainty. We show that volatility is the key driver behind (de......-)centralization. We provide an analytical solution for the 2-branch model and show that a liquidity center can be interpreted as an option on immediate liquidity. Therefore, its value can be interpreted as the price of information, i.e., the price of knowing the exact demand. Furthermore, we derive the threshold...... above which it is advantageous to open a liquidity center and show that it is a function of the volatility and the characteristic of the bank network. Finally, we discuss the n-branch model for real-world banking groups (10-60 branches) and show that it can be solved with high granularity (100 scenarios...

  17. Draw the Line!

    DEFF Research Database (Denmark)

    present proceedings from the UPGEM conference "Draw the Line!" in Copenhagen May 2008. The proceedings include contributions by UPGEM researchers, conference speeches by other researchers, politicians and gender equality officers in which they relate their work and research with the research done in UPGEM......Draw the Line! International Conference, Copenhagen 2008 Papers, proceedings and recommendations is the second publication of the international three year long project "Understanding Puzzles in the Gendered European Map" (UPGEM), which is financed by the European Commission. In this publication we....... The UPGEM research has previously been published in national reports from each of the partner countries (Denmark, Estonia, Finland, Italy and Poland). In these individual national reports of universities as workplaces for male and female researchers we discuss scientific cultures in physics embedded...

  18. Determination of bovine lactoferrin in dairy products by ultra-high performance liquid chromatography–tandem mass spectrometry based on tryptic signature peptides employing an isotope-labeled winged peptide as internal standard

    International Nuclear Information System (INIS)

    Zhang, Jingshun; Lai, Shiyun; Cai, Zengxuan; Chen, Qi; Huang, Baifen; Ren, Yiping

    2014-01-01

    Highlights: • A UHPLC–MS/MS method for quantification of bovine lactoferrin was developed. • Tryptic fragment LRPVAAEIYGTK was chosen as signature peptide of bovine lactoferrin. • A winged peptide containing isotopically-labeled signature peptide was designed as internal standard. • The method for determining lactoferrin does not discriminate between the different forms of lactoferrin. • Meet the growing demand to quantify bovine lactoferrin in different dairy products. - Abstract: A new and sensitive determination method was developed for bovine lactoferrin in dairy products including infant formulas based on the signature peptide by ultra high-performance liquid chromatography and triple-quadrupole tandem mass spectrometry under the multiple reaction monitoring mode. The simple pretreatment procedures included the addition of a winged peptide containing the isotope-labeled signature peptide as internal standard, followed by an enzymatic digestion with trypsin. The signature peptide was chosen and identified from the tryptic hydrolyzates of bovine lactoferrin by ultra high-performance liquid chromatography and quadrupole-time-of-flight tandem mass spectrometry based on sequence database search. Analytes were separated on an ACQUITY UPLC BEH 300 C18 column and monitored by MS/MS in seven minutes. Quantitative result bias due to matrix effect and tryptic efficiency was corrected through the use of synthetic isotope-labeled standards. The limit of detection and limit of quantification were 0.3 mg/100 g and 1.0 mg/100 g, respectively. Bovine lactoferrin within the concentration range of 10–1000 nmol L −1 showed a strong linear relationship with a linear correlation coefficient (r) of >0.998. The intra- and inter-day precision of the method were RSD < 6.5% and RSD < 7.1%, respectively. Excellent repeatability (RSD < 6.4%) substantially supported the application of this method for the determination of bovine lactoferrin in dairy samples. The present

  19. Determination of bovine lactoferrin in dairy products by ultra-high performance liquid chromatography–tandem mass spectrometry based on tryptic signature peptides employing an isotope-labeled winged peptide as internal standard

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jingshun [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Lai, Shiyun [Beingmate Research Institute, Beingmate Baby and Child Food Co., Ltd., Hangzhou 310007 (China); Cai, Zengxuan [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Chen, Qi [Beingmate Research Institute, Beingmate Baby and Child Food Co., Ltd., Hangzhou 310007 (China); Huang, Baifen [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China); Ren, Yiping, E-mail: renyiping@263.net [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051 (China)

    2014-06-01

    Highlights: • A UHPLC–MS/MS method for quantification of bovine lactoferrin was developed. • Tryptic fragment LRPVAAEIYGTK was chosen as signature peptide of bovine lactoferrin. • A winged peptide containing isotopically-labeled signature peptide was designed as internal standard. • The method for determining lactoferrin does not discriminate between the different forms of lactoferrin. • Meet the growing demand to quantify bovine lactoferrin in different dairy products. Abstract: A new and sensitive determination method was developed for bovine lactoferrin in dairy products including infant formulas based on the signature peptide by ultra high-performance liquid chromatography and triple-quadrupole tandem mass spectrometry under the multiple reaction monitoring mode. The simple pretreatment procedures included the addition of a winged peptide containing the isotope-labeled signature peptide as internal standard, followed by an enzymatic digestion with trypsin. The signature peptide was chosen and identified from the tryptic hydrolyzates of bovine lactoferrin by ultra high-performance liquid chromatography and quadrupole-time-of-flight tandem mass spectrometry based on sequence database search. Analytes were separated on an ACQUITY UPLC BEH 300 C18 column and monitored by MS/MS in seven minutes. Quantitative result bias due to matrix effect and tryptic efficiency was corrected through the use of synthetic isotope-labeled standards. The limit of detection and limit of quantification were 0.3 mg/100 g and 1.0 mg/100 g, respectively. Bovine lactoferrin within the concentration range of 10–1000 nmol L⁻¹ showed a strong linear relationship with a linear correlation coefficient (r) of >0.998. The intra- and inter-day precision of the method were RSD < 6.5% and RSD < 7.1%, respectively. Excellent repeatability (RSD < 6.4%) substantially supported the application of this method for the determination of bovine lactoferrin in dairy samples. The present method

  20. Spectral Line Shapes. Proceedings

    International Nuclear Information System (INIS)

    Zoppi, M.; Ulivi, L.

    1997-01-01

    These proceedings represent papers presented at the 13th International Conference on Spectral Line Shapes which was held in Firenze,Italy from June 16-21, 1996. The topics covered a wide range of subjects emphasizing the physical processes associated with the formation of line profiles: high and low density plasma; atoms and molecules in strong laser fields, Dopple-free and ultra-fine spectroscopy; the line shapes generated by the interaction of neutrals, atoms and molecules, where the relavant quantities are single particle properties, and the interaction-induced spectroscopy. There were 131 papers presented at the conference, out of these, 6 have been abstracted for the Energy Science and Technology database

  1. Eficácia do tubo de borracha como revestimento interno em anastomoses esofágicas em cães Efficacy of the rubber tube as an internal lining in the esophageal anastomosis in dogs

    Directory of Open Access Journals (Sweden)

    Neil Ferreira Novo

    1999-07-01

    Full Text Available O objetivo deste trabalho foi avaliar a técnica operatória de revestimento interno com dreno de Penrose nas anastomoses esôfago-esofágicas cervicais término-terminais. Foram utilizados 16 cães machos com pesos compreendidos entre 8 e 10Kg, distribuídos em dois grupos de 8 animais, baseados nos períodos de pós-operatórios, de 7 ou 14 dias. Em cada grupo, as anastomoses foram avaliadas em seus aspectos clínicos, macroscópicos e microscópicos. Nenhuma fístula ou óbito foi observado no pós-operatório. Todos os animais apresentaram disfagia por tempo mínimo de 7 dias. À microscopia óptica, observou-se deficiência na regeneração das túnicas submucosa e mucosa nas anastomoses. Os resultados observados permitem concluir que a anastomose esôfago-esofágica cervical com revestimento interno com dreno de Penrose é factível, porém não é isenta de complicações.The aim of this work was to evaluate the operatory technique using a Penrose drain as an internal lining in the esophagus-esophageal cervical anastomosis. Sixteen male dogs with an average weight between 8 and 10kg were distributed in two groups of 8 animals based on post-operative periods: 7 and 14 days. In each group, the morbidity and macroscopic and microscopic alterations caused by anastomosis were evaluated. No fistula and no death were observed in the post-operative period. All animals presented dysphagia for at least 7 days. Optical microscopic analysis revealed deficiency of regeneration in the submucous and mucous tunics in the anastomosis line. The results permitted to conclude that the esophagus-esophageal cervical anastomosis using a Penrose drain as an internal lining is possible, but presents complications.

  2. Immobilization of organic liquid wastes

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.

    1985-01-01

    This report describes a portland cement immobilization process for the disposal treatment of radioactive organic liquid wastes which would be generated in a a FFTF fuels reprocessing line. An incineration system already on-hand was determined to be too costly to operate for the 100 to 400 gallons per year organic liquid. Organic test liquids were dispersed into an aqueous phosphate liquid using an emulsifier. A total of 109 gallons of potential and radioactive aqueous immiscible organic liquid wastes from Hanford 300 Area operations were solidified with portland cement and disposed of as solid waste during a 3-month test program with in-drum mixers. Waste packing efficiencies varied from 32 to 40% and included pump oils, mineral spirits, and TBP-NPH type solvents

  3. Flow-induced vibration of steam generator helical tubes subjected to external liquid cross flow and internal two-phase flow

    International Nuclear Information System (INIS)

    Jong Chull Jo; Myung Jo Jhung; Woong Sik Kim; Hho Jung Kim

    2005-01-01

    Full text of publication follows: This paper addresses the potential flow-induced vibration problems in a helically-coiled tube steam generator of integral-type nuclear reactor, of which the tubes are subjected to liquid cross flow externally and multi-phase flow externally. The thermal-hydraulic conditions of both tube side and shell side flow fields are predicted using a general purpose computational fluid dynamics code employing the finite volume element modeling. To get the natural frequency and corresponding mode shape of the helical type tubes with various conditions, a finite element analysis code is used. Based on the results of both helical coiled tube steam generator thermal-hydraulic and coiled tube modal analyses, turbulence-induced vibration and fluid-elastic instability analyses are performed. And then the potential for damages on the tubes due to either turbulence-induced vibration or fluid-elastic instability is assessed. In the assessment, special emphases are put on the detailed investigation for the effects of support conditions, coil diameter, and helix pitch on the modal, vibration amplitude and instability characteristics of tubes, from which a technical information and basis needed for designers and regulatory reviewers can be derived. (authors)

  4. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  5. Quality of Canned mandarin as affected by preservation liquid

    Directory of Open Access Journals (Sweden)

    Antonio Jose Perez-Lopez

    2010-12-01

    Full Text Available This study is integrated within a research line dedicated to evaluate different options to introduce mandarin in Spanish agro-food industries and in both national and international markets. The effects of different preservation liquids (sucrose solution, sucrose and ascorbic acid solution, grape, and grapefruit juices, soluble solids (10, 12, 14 ºBrix, and thermal processing (30 seconds at 98 ºC on vitamin C, color, carotenoids and sensory quality of canned Satsuma mandarin segments were studied. The liquid preservation that presented the best results was grapefruit juice, which provided the highest vitamin C (323 mg.L-1 and total carotenoids (16.4 mg.L-1 contents (the main carotenoid found was β-cryptoxanthin, intense orange color, high thermal stability, and very good sensory quality (e.g. intense floral and fresh-mandarin aromas and low levels of off-flavors.

  6. Vapor equilibrium data for the systems Ar--N/sub 2/, Kr--Ar, Kr--N/sub 2/, and Xe--Kr, as well as the liquidus lines of solid xenon and of solid krypton in liquid air component mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Mastera, S J

    1977-01-15

    The knowledge of vapor-liquid equilibrium data of real gas mixtures makes possible a precise design of a low temperature distillation system. The noble gas isotopes Kr and Xe are formed as a result of nuclear fission. They reach the off-gas, where they must be separated by cryogenic methods, among others, in order to reduce radiological contamination of the environment. Consequently, an equilibrium apparatus was constructed inhouse, which worked according to a dynamical measurement method. The following low temperature measurements were performed with this apparatus: (1) to test the apparatus with the Ar--N/sub 2/ system, at temperatures of 80, 85, 90, 95, and 100 degrees K; (2) with the Kr--Ar system, at temperatures of 115, 116.5, 120, and 125 degrees K; (3) with the Kr--N/sub 2/ system, at temperatures of 100, 105, at 110 degrees K in the N/sub 2/-rich existence range of the liquid phase above the solubility limit, and at temperatures of 115, 120, and 125 degrees K in the entire concentration range. No data at all were previously known about this important system. (4) In the Xe-Kr system, at temperatures of 150, 155, and 160 degrees K, in the Kr-rich liquid existence range above the solubility limit, and at the temperature steps 165, 166, and 170 degrees in the entire concentration range. The consistency of the equilibrium data thus determined was tested with the computer program SYMFIT. These measurements were completed by determining the solubility limits (= liquidus lines) of solid Kr in a liquid Kr--Ar mixture or in a liquid Kr--N/sub 2/ mixture, as well as the solubility limit of solid Xe in a liquid Xe--Kr mixture. The measurement points for the liquidus lines were associated with the respective pressure and respective temperature over the entire concentration range. The experimentally determined data are displayed on tables and graphs. The utilized measurement equipment, with its glass equilibrium cell, is described.

  7. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    Science.gov (United States)

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  8. Liquid explosives

    CERN Document Server

    Liu, Jiping

    2015-01-01

    The book drawing on the author's nearly half a century of energetic materials research experience intends to systematically review the global researches on liquid explosives. The book focuses on the study of the conception, explosion mechanism, properties and preparation of liquid explosives. It provides a combination of theoretical knowledge and practical examples in a reader-friendly style. The book is likely to be interest of university researchers and graduate students in the fields of energetic materials, blasting engineering and mining.

  9. Automated Gain Control and Internal Calibration With External Ion Accumulation Capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance.

    Energy Technology Data Exchange (ETDEWEB)

    Belov, Mikhail E.(VISITORS); Zhang, Rui (BATTELLE (PACIFIC NW LAB)); Strittmatter, Eric F.(BATTELLE (PACIFIC NW LAB)); Prior, David C.(BATTELLE (PACIFIC NW LAB)); Tang, Keqi (BATTELLE (PACIFIC NW LAB)); Smith, Richard D.(BATTELLE (PACIFIC NW LAB))

    2003-08-15

    When combined with capillary LC separations, Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICR MS) has increasingly been applied for advanced characterization of proteolytic digests. Incorporation of external (to the ICR cell) ion accumulation multipoles with FTICR for ion pre selection and accumulation has enhanced the dynamic range, sensitivity and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in overfilling of the external trap, resulting in m/z discrimination and fragmentation of peptide ions. An excessive space charge trapped in the ICR cell causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) for protein identification. To eliminate m/z discrimination in the external ion trap, further increase the duty cycle and improve MMA, we developed a capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as Automated Gain Control (AGC), in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The system was initially evaluated in the analysis of a 0.5 mg/mL tryptic digest of bovine serum albumin. The implementation of LC/ESI/AGC/FTICR with internal calibration gave rise to a {approx} 10-fold increase in the number of identified tryptic peptides within mass measurement accuracy of 2 ppm as compared to that detected during the conventional LC/FTICR run with a fixed ion accumulation time and external calibration.

  10. Quantification of endogenous metabolites by the postcolumn infused-internal standard method combined with matrix normalization factor in liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liao, Hsiao-Wei; Chen, Guan-Yuan; Wu, Ming-Shiang; Liao, Wei-Chih; Tsai, I-Lin; Kuo, Ching-Hua

    2015-01-02

    Quantification of endogenous metabolites has enabled the discovery of biomarkers for diagnosis and provided for an understanding of disease etiology. The standard addition and stable isotope labeled-internal standard (SIL-IS) methods are currently the most widely used approaches to quantifying endogenous metabolites, but both have some limitations for clinical measurement. In this study, we developed a new approach for endogenous metabolite quantification by the postcolumn infused-internal standard (PCI-IS) method combined with the matrix normalization factor (MNF) method. MNF was used to correct the difference in MEs between standard solution and biofluids, and PCI-IS additionally tailored the correction of the MEs for individual samples. Androstenedione and testosterone were selected as test articles to verify this new approach to quantifying metabolites in plasma. The repeatability (n=4 runs) and intermediate precision (n=3 days) in terms of the peak area of androstenedione and testosterone at all tested concentrations were all less than 11% relative standard deviation (RSD). The accuracy test revealed that the recoveries were between 95.72% and 113.46%. The concentrations of androstenedione and testosterone in fifty plasma samples obtained from healthy volunteers were quantified by the PCI-IS combined with the MNF method, and the quantification results were compared with the results of the SIL-IS method. The Pearson correlation test showed that the correlation coefficient was 0.98 for both androstenedione and testosterone. We demonstrated that the PCI-IS combined with the MNF method is an effective and accurate method for quantifying endogenous metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. High performance liquid chromatographic determination of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-08

    ) high performance liquid chromatography (HPLC) grade .... applications. These are important requirements if the reagent is to be applicable to on-line pre or post column derivatisation in a possible automation of the analytical.

  12. PREFACE: Functionalized Liquid Liquid Interfaces

    Science.gov (United States)

    Girault, Hubert; Kornyshev, Alexei A.; Monroe, Charles W.; Urbakh, Michael

    2007-09-01

    Most natural processes take place at interfaces. For this reason, surface science has been a focal point of modern research. At solid-liquid interfaces one can induce various species to adsorb or react, and thus may study interactions between the substrate and adsorbates, kinetic processes, optical properties, etc. Liquid-liquid interfaces, formed by immiscible liquids such as water and oil, have a number of distinctive features. Both sides of the interface are amenable to detailed physical and chemical analysis. By chemical or electrochemical means, metal or semiconductor nanoparticles can be formed or localised at the interface. Surfactants can be used to tailor surface properties, and also to place organic molecular or supermolecular constructions at the boundary between the liquids. Electric fields can be used to drive ions from one fluid to another, or even change the shape of the interface itself. In many cases, both liquids are optically transparent, making functionalized liquid-liquid interfaces promising for various optical applications based on the transmission or reflection of light. An advantage common to most of these systems is self-assembly; because a liquid-liquid interface is not mechanically constrained like a solid-liquid interface, it can easily access its most stable state, even after it has been driven far from equilibrium. This special issue focuses on four modes of liquid-liquid interfacial functionalization: the controlled adsorption of molecules or nanoparticles, the formation of adlayers or films, electrowetting, and ion transfer or interface-localized reactions. Interfacial adsorption can be driven electrically, chemically, or mechanically. The liquid-liquid interface can be used to study how anisotropic particles orient at a surface under the influence of a field, how surfactants interact with other adsorbates, and how nanoparticles aggregate; the transparency of the interface also makes the chirality of organic adsorbates amenable to

  13. production lines

    Directory of Open Access Journals (Sweden)

    Jingshan Li

    2000-01-01

    Full Text Available In this work, serial production lines with finished goods buffers operating in the pull regime are considered. The machines are assumed to obey Bernoulli reliability model. The problem of satisfying customers demand is addressed. The level of demand satisfaction is quantified by the due-time performance (DTP, which is defined as the probability to ship to the customer a required number of parts during a fixed time interval. Within this scenario, the definitions of DTP bottlenecks are introduced and a method for their identification is developed.

  14. Private and Public Supply of Liquidity

    OpenAIRE

    Bengt Holmstrom; Jean Tirole

    1998-01-01

    This paper addresses a basic yet unresolved question: Do claims on private assets provide sufficient liquidity for an efficient functioning of the productive sector? Or does the State have a role in creating liquidity and regulating it either through adjustments in the stock of government securities or by other means? In our model, firms can meet future liquidity needs in three ways: by issuing new claims and diluting old ones, by obtaining a credit credit line from a financial intermediary, ...

  15. Optimal Liquidation under Stochastic Liquidity

    OpenAIRE

    Becherer, Dirk; Bilarev, Todor; Frentrup, Peter

    2016-01-01

    We solve explicitly a two-dimensional singular control problem of finite fuel type for infinite time horizon. The problem stems from the optimal liquidation of an asset position in a financial market with multiplicative and transient price impact. Liquidity is stochastic in that the volume effect process, which determines the inter-temporal resilience of the market in spirit of Predoiu, Shaikhet and Shreve (2011), is taken to be stochastic, being driven by own random noise. The optimal contro...

  16. Decompression-induced melting of ice IV and the liquid-liquid transition in water

    Science.gov (United States)

    Mishima, Osamu; Stanley, H. Eugene

    1998-03-01

    Although liquid water has been the focus of intensive research for over 100 years, a coherent physical picture that unifies all of the known anomalies of this liquid, is still lacking. Some of these anomalies occur in the supercooled region, and have been rationalized on the grounds of a possible retracing of the liquid-gas spinodal (metastability limit) line into the supercooled liquid region, or alternatively the presence of a line of first-order liquid-liquid phase transitions in this region which ends in a critical point,. But these ideas remain untested experimentally, in part because supercooled water can be probed only above the homogeneous nucleation temperature TH at which water spontaneously crystallizes. Here we report an experimental approach that is not restricted by the barrier imposed by TH, involving measurement of the decompression-induced melting curves of several high-pressure phases of ice in small emulsified droplets. We find that the melting curve for ice IV seems to undergo a discontinuity at precisely the location proposed for the line of liquid-liquid phase transitions. This is consistent with, but does not prove, the coexistence of two different phases of (supercooled) liquid water. From the experimental data we calculate a possible Gibbs potential surface and a corresponding equation of state for water, from the forms of which we estimate the coordinates of the liquid-liquid critical point to be at pressure Pc ~ 0.1GPa and temperature Tc ~ 220K.

  17. A Realistic International Economics.

    Science.gov (United States)

    Culbertson, John M.

    1987-01-01

    Criticizes college textbooks for adopting a "party line" of laissez-faire economic doctrine which asserts the benefits of free trade. Offers an alternative interpretation of international trade, covering such topics as the effect of unregulated international trade on wage levels, and international lending. (JDH)

  18. Line facilities outline

    International Nuclear Information System (INIS)

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  19. Thermodynamic properties by equation of state and from Ab initio molecular dynamics of liquid potassium under pressure

    Science.gov (United States)

    Li, Huaming; Tian, Yanting; Sun, Yongli; Li, Mo; Nonequilibrium materials; physics Team; Computational materials science Team

    In this work, we apply a general equation of state of liquid and Ab initio molecular-dynamics method to study thermodynamic properties in liquid potassium under high pressure. Isothermal bulk modulus and molar volume of molten sodium are calculated within good precision as compared with the experimental data. The calculated internal energy data and the calculated values of isobaric heat capacity of molten potassium show the minimum along the isothermal lines as the previous result obtained in liquid sodium. The expressions for acoustical parameter and nonlinearity parameter are obtained based on thermodynamic relations from the equation of state. Both parameters for liquid potassium are calculated under high pressure along the isothermal lines by using the available thermodynamic data and numeric derivations. Furthermore, Ab initio molecular-dynamics simulations are used to calculate some thermodynamic properties of liquid potassium along the isothermal lines. Scientific Research Starting Foundation from Taiyuan university of Technology, Shanxi Provincial government (``100-talents program''), China Scholarship Council and National Natural Science Foundation of China (NSFC) under Grant No. 51602213.

  20. Crystal-liquid-gas phase transitions and thermodynamic similarity

    CERN Document Server

    Skripov, Vladimir P; Schmelzer, Jurn W P

    2006-01-01

    Professor Skripov obtained worldwide recognition with his monograph ""Metastable liquids"", published in English by Wiley & Sons. Based upon this work and another monograph published only in Russia, this book investigates the behavior of melting line and the properties of the coexisting crystal and liquid phase of simple substances across a wide range of pressures, including metastable states of the coexisting phases. The authors derive new relations for the thermodynamic similarity for liquid-vapour phase transition, as well as describing solid-liquid, liquid-vapor and liquid-liquid phase tra

  1. Liquidity risk and contagion for liquid funds

    OpenAIRE

    Darolles , Serge; Dudek , Jeremy; Le Fol , Gaëlle

    2014-01-01

    Fund managers face liquidity problems but they have to distinguish the market liquidity risk implied by their assets and the funding liquidity risk. This latter is due to both the liquidity mismatch between assets and liabilities and the redemption risk due to the possible outflows from clients. The main contribution of this paper is the analysis of contagion looking at common market liquidity problems to detect funding liquidity problems. Using the CDS Bond Spread basis as a liquidity indica...

  2. Parallel Lines

    Directory of Open Access Journals (Sweden)

    James G. Worner

    2017-05-01

    Full Text Available James Worner is an Australian-based writer and scholar currently pursuing a PhD at the University of Technology Sydney. His research seeks to expose masculinities lost in the shadow of Australia’s Anzac hegemony while exploring new opportunities for contemporary historiography. He is the recipient of the Doctoral Scholarship in Historical Consciousness at the university’s Australian Centre of Public History and will be hosted by the University of Bologna during 2017 on a doctoral research writing scholarship.   ‘Parallel Lines’ is one of a collection of stories, The Shapes of Us, exploring liminal spaces of modern life: class, gender, sexuality, race, religion and education. It looks at lives, like lines, that do not meet but which travel in proximity, simultaneously attracted and repelled. James’ short stories have been published in various journals and anthologies.

  3. Response function of a moving contact line

    Science.gov (United States)

    Perrin, H.; Belardinelli, D.; Sbragaglia, M.; Andreotti, B.

    2018-04-01

    The hydrodynamics of a liquid-vapor interface in contact with a heterogeneous surface is largely impacted by the presence of defects at the smaller scales. Such defects introduce morphological disturbances on the contact line and ultimately determine the force exerted on the wedge of liquid in contact with the surface. From the mathematical point of view, defects introduce perturbation modes, whose space-time evolution is governed by the interfacial hydrodynamic equations of the contact line. In this paper we derive the response function of the contact line to such generic perturbations. The contact line response may be used to design simplified one-dimensional time-dependent models accounting for the complexity of interfacial flows coupled to nanoscale defects, yet offering a more tractable mathematical framework to explore contact line motion through a disordered energy landscape.

  4. Hidden Liquidity

    OpenAIRE

    Cebiroglu, Gökhan; Horst, Ulrich

    2012-01-01

    We cross-sectionally analyze the presence of aggregated hidden depth and trade volume in the S&P 500 and identify its key determinants. We find that the spread is the main predictor for a stock’s hidden dimension, both in terms of traded and posted liquidity. Our findings moreover suggest that large hidden orders are associated with larger transaction costs, higher price impact and increased volatility. In particular, as large hidden orders fail to attract (latent) liquidity to the market, hi...

  5. Applicable international environmental impact assessment laws for ...

    African Journals Online (AJOL)

    Lawrence Hart

    1971-05-28

    May 28, 1971 ... appraise selected International Environmental laws and the Nigerian Environmental Impact Assessment methodology ... maze of pipelines, delivery lines, flow lines, canals and .... Toxic Materials and international waterways.

  6. Liquidity management through financial planning

    Directory of Open Access Journals (Sweden)

    Kameníková Katarína

    2001-12-01

    Full Text Available One of the basic goals of financial management is to provide financial property and capital for running of the firm, as well as for its development, that means provide optimal firm´s liquidity.To improve liquidity is possible provide through various ways. In present time there is increasing importance of financial planning., where planning of liquidity presents one of its integral part. Therefore I deal in presented paper with possible liquidity improvement through calculation of financial planning in chosen slovac magnesite firm, exploitating and elaborating magnesite raw material.For creating of financial plann of liquidity I chosed to use one of the practical methods - method of financial indexes. Such method presents process of planning optimal liquidity with providing of required rentability. Such plann must provide balance between income and outcome, as well as secure achievment of expected profit.I used tools of financial planning for calculation of possible liquidity improvement in mentioned firm, where present financial situation is characterised by law liquidity, but high rentability. Such position presents transitive crisis situation, therefore firm must create new financial property or decrease liabilities, in order to overcome negative state of liquidity.Performed calculation showed, that change in balance sheet due to the growth of financial property will improve liquidity, rentability will be maintained, therefore firm will be able to transit from crisis situation.Providing of liquidity will present one of possible way how to care for financial health of firm. But such process is not simple, it must be done with connection to the changes of internal and external conditions of the firm.

  7. 26 CFR 1.860F-1 - Qualified liquidations.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Qualified liquidations. 1.860F-1 Section 1.860F-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860F-1 Qualified liquidations. A plan of...

  8. Liquid ventilation.

    Science.gov (United States)

    Sarkar, Suman; Paswan, Anil; Prakas, S

    2014-01-01

    Human have lungs to breathe air and they have no gills to breath liquids like fish. When the surface tension at the air-liquid interface of the lung increases as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV) is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen as the inert carrier of oxygen and carbon dioxide offers a number of advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. It is well-known that respiratory diseases are one of the most common causes of morbidity and mortality in intensive care unit. During the past few years several new modalities of treatment have been introduced. One of them and probably the most fascinating, is of LV. Partial LV, on which much of the existing research has concentrated, requires partial filling of lungs with perfluorocarbons (PFC's) and ventilation with gas tidal volumes using conventional mechanical ventilators. Various physico-chemical properties of PFC's make them the ideal media. It results in a dramatic improvement in lung compliance and oxygenation and decline in mean airway pressure and oxygen requirements. No long-term side-effect reported.

  9. Liquid Marbles

    KAUST Repository

    Khalil, Kareem

    2012-12-01

    Granulation, the process of formation of granules from a combination of base powders and binder liquids, has been a subject of research for almost 50 years, studied extensively for its vast applications, primarily to the pharmaceutical industry sector. The principal aim of granulation is to form granules comprised of the active pharmaceutical ingredients (API’s), which have more desirable handling and flowability properties than raw powders. It is also essential to ensure an even distribution of active ingredients within a tablet with the goal of achieving time‐controlled release of drugs. Due to the product‐specific nature of the industry, however, data is largely empirical [1]. For example, the raw powders used can vary in size by two orders of magnitude with narrow or broad size distributions. The physical properties of the binder liquids can also vary significantly depending on the powder properties and required granule size. Some significant progress has been made to better our understanding of the overall granulation process [1] and it is widely accepted that the initial nucleation / wetting stage, when the binder liquid first wets the powders, is key to the whole process. As such, many experimental studies have been conducted in attempt to elucidate the physics of this first stage [1], with two main mechanisms being observed – classified by Ivenson [1] as the “Traditional description” and the “Modern Approach”. See Figure 1 for a graphical definition of these two mechanisms. Recent studies have focused on the latter approach [1] and a new, exciting development in this field is the Liquid Marble. This interesting formation occurs when a liquid droplet interacts with a hydrophobic (or superhydrophobic) powder. The droplet can become encased in the powder, which essentially provides a protective “shell” or “jacket” for the liquid inside [2]. The liquid inside is then isolated from contact with other solids or liquids and has some

  10. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  11. Screen-Printed Electrode Modified by Bismuth /Fe3O4 Nanoparticle/Ionic Liquid Composite Using Internal Standard Normalization for Accurate Determination of Cd(II in Soil

    Directory of Open Access Journals (Sweden)

    Hui Wang

    2017-12-01

    Full Text Available The quality and safety of agricultural products are threatened by heavy metal ions in soil, which can be absorbed by the crops, and then accumulated in the human body through the food chain. In this paper, we report a low-cost and easy-to-use screen-printed electrode (SPE for cadmium ion (Cd(II detection based on differential pulse voltammetry (DPV, which decorated with ionic liquid (IL, magnetite nanoparticle (Fe3O4, and deposited a bismuth film (Bi. The characteristics of Bi/Fe3O4/ILSPE were investigated using scanning electron microscopy, cyclic voltammetry, impedance spectroscopy, and linear sweep voltammetry. We found that the sensitivity of SPE was improved dramatically after functionalized with Bi/Fe3O4/IL. Under optimized conditions, the concentrations of Cd(II are linear with current responses in a range from 0.5 to 40 µg/L with the lowest detection limit of 0.05 µg/L (S/N = 3. Additionally, the internal standard normalization (ISN was used to process the response signals of Bi/Fe3O4/ILSPE and established a new linear equation. For detecting three different Cd(II concentrations, the root-mean-square error using ISN (0.25 is lower than linear method (0.36. Finally, the proposed electrode was applied to trace Cd(II in soil samples with the recovery in the range from 91.77 to 107.83%.

  12. Validation of a reversed-phase high-performance liquid chromatographic method for the determination of free amino acids in rice using l-theanine as the internal standard.

    Science.gov (United States)

    Liyanaarachchi, G V V; Mahanama, K R R; Somasiri, H P P S; Punyasiri, P A N

    2018-02-01

    The study presents the validation results of the method carried out for analysis of free amino acids (FAAs) in rice using l-theanine as the internal standard (IS) with o-phthalaldehyde (OPA) reagent using high-performance liquid chromatography-fluorescence detection. The detection and quantification limits of the method were in the range 2-16μmol/kg and 3-19μmol/kg respectively. The method had a wide working range from 25 to 600μmol/kg for each individual amino acid, and good linearity with regression coefficients greater than 0.999. Precision measured in terms of repeatability and reproducibility, expressed as percentage relative standard deviation (% RSD) was below 9% for all the amino acids analyzed. The recoveries obtained after fortification at three concentration levels were in the range 75-105%. In comparison to l-norvaline, findings revealed that l-theanine is suitable as an IS and the validated method can be used for FAA determination in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Impact of a multidimensional infection control approach on central line-associated bloodstream infections rates in adult intensive care units of 8 cities of Turkey: findings of the International Nosocomial Infection Control Consortium (INICC)

    Science.gov (United States)

    2013-01-01

    Background Central line-associated bloodstream infections (CLABs) have long been associated with excess lengths of stay, increased hospital costs and mortality attributable to them. Different studies from developed countries have shown that practice bundles reduce the incidence of CLAB in intensive care units. However, the impact of the bundle strategy has not been systematically analyzed in the adult intensive care unit (ICU) setting in developing countries, such as Turkey. The aim of this study is to analyze the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional infection control approach to reduce the rates of CLAB in 13 ICUs of 13 INICC member hospitals from 8 cities of Turkey. Methods We conducted active, prospective surveillance before-after study to determine CLAB rates in a cohort of 4,017 adults hospitalized in ICUs. We applied the definitions of the CDC/NHSN and INICC surveillance methods. The study was divided into baseline and intervention periods. During baseline, active outcome surveillance of CLAB rates was performed. During intervention, the INICC multidimensional approach for CLAB reduction was implemented and included the following measures: 1- bundle of infection control interventions, 2- education, 3- outcome surveillance, 4- process surveillance, 5- feedback of CLAB rates, and 6- performance feedback on infection control practices. CLAB rates obtained in baseline were compared with CLAB rates obtained during intervention. Results During baseline, 3,129 central line (CL) days were recorded, and during intervention, we recorded 23,463 CL-days. We used random effects Poisson regression to account for clustering of CLAB rates within hospital across time periods. The baseline CLAB rate was 22.7 per 1000 CL days, which was decreased during the intervention period to 12.0 CLABs per 1000 CL days (IRR 0.613; 95% CI 0.43 – 0.87; P 0.007). This amounted to a 39% reduction in the incidence rate of CLAB

  14. VT Digital Line Graph Miscellaneous Transmission Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  15. Comprehensive profiling of mercapturic acid metabolites from dietary acrylamide as short-term exposure biomarkers for evaluation of toxicokinetics in rats and daily internal exposure in humans using isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Zhejiang Key Laboratory for Agro-Food Processing, Zhejiang R & D Center for Food Technology and Equipment, Fuli Institute of Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Wang, Qiao; Cheng, Jun [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Zhang, Jingshun; Xu, Jiaojiao [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, Zhejiang (China); Ren, Yiping, E-mail: renyiping@263.net [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, Zhejiang (China)

    2015-09-24

    Mercapturic acid metabolites from dietary acrylamide are important short-term exposure biomarkers for evaluating the in vivo toxicity of acrylamide. Most of studies have focused on the measurement of two metabolites, N-acetyl-S-(2-carbamoylethyl)-L-cysteine (AAMA) and N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-L-cysteine (GAMA). Thus, the comprehensive profile of acrylamide urinary metabolites cannot be fully understood. We developed an isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of all four mercapturic acid adducts of acrylamide and its primary metabolite glycidamide under the electroscopy ionization negative (ESI-) mode in the present study. The limit of detection (LOD) and limit of quantification (LOQ) of the analytes ranged 0.1–0.3 ng/mL and 0.4–1.0 ng/mL, respectively. The recovery rates with low, intermediate and high spiking levels were calculated as 95.5%–105.4%, 98.2%–114.0% and 92.2%–108.9%, respectively. Acceptable within-laboratory reproducibility (RSD < 7.0%) substantially supported the use of current method for robust analysis. Rapid pretreatment procedures and short run time (8 min per sample) ensured good efficiency of metabolism profiling, indicating a wide application for investigating short-term internal exposure of dietary acrylamide. Our proposed UHPLC-MS/MS method was successfully applied to the toxicokinetic study of acrylamide in rats. Meanwhile, results of human urine analysis indicated that the levels of N-acetyl-S-(2-carbamoylethyl)-L-cysteine-sulfoxide (AAMA-sul), which did not appear in the mercapturic acid metabolites in rodents, were more than the sum of GAMA and N-acetyl-S-(1-carbamoyl-2-hydroxyethyl)-L-cysteine (iso-GAMA). Thus, AAMA-sul may alternatively become a specific biomarker for investigating the acrylamide exposure in humans. Current proposed method provides a substantial methodology support for comprehensive

  16. Comprehensive profiling of mercapturic acid metabolites from dietary acrylamide as short-term exposure biomarkers for evaluation of toxicokinetics in rats and daily internal exposure in humans using isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    Zhang, Yu; Wang, Qiao; Cheng, Jun; Zhang, Jingshun; Xu, Jiaojiao; Ren, Yiping

    2015-01-01

    Mercapturic acid metabolites from dietary acrylamide are important short-term exposure biomarkers for evaluating the in vivo toxicity of acrylamide. Most of studies have focused on the measurement of two metabolites, N-acetyl-S-(2-carbamoylethyl)-L-cysteine (AAMA) and N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-L-cysteine (GAMA). Thus, the comprehensive profile of acrylamide urinary metabolites cannot be fully understood. We developed an isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of all four mercapturic acid adducts of acrylamide and its primary metabolite glycidamide under the electroscopy ionization negative (ESI-) mode in the present study. The limit of detection (LOD) and limit of quantification (LOQ) of the analytes ranged 0.1–0.3 ng/mL and 0.4–1.0 ng/mL, respectively. The recovery rates with low, intermediate and high spiking levels were calculated as 95.5%–105.4%, 98.2%–114.0% and 92.2%–108.9%, respectively. Acceptable within-laboratory reproducibility (RSD < 7.0%) substantially supported the use of current method for robust analysis. Rapid pretreatment procedures and short run time (8 min per sample) ensured good efficiency of metabolism profiling, indicating a wide application for investigating short-term internal exposure of dietary acrylamide. Our proposed UHPLC-MS/MS method was successfully applied to the toxicokinetic study of acrylamide in rats. Meanwhile, results of human urine analysis indicated that the levels of N-acetyl-S-(2-carbamoylethyl)-L-cysteine-sulfoxide (AAMA-sul), which did not appear in the mercapturic acid metabolites in rodents, were more than the sum of GAMA and N-acetyl-S-(1-carbamoyl-2-hydroxyethyl)-L-cysteine (iso-GAMA). Thus, AAMA-sul may alternatively become a specific biomarker for investigating the acrylamide exposure in humans. Current proposed method provides a substantial methodology support for comprehensive

  17. Similarity law for Widom lines and coexistence lines.

    Science.gov (United States)

    Banuti, D T; Raju, M; Ihme, M

    2017-05-01

    The coexistence line of a fluid separates liquid and gaseous states at subcritical pressures, ending at the critical point. Only recently, it became clear that the supercritical state space can likewise be divided into regions with liquidlike and gaslike properties, separated by an extension to the coexistence line. This crossover line is commonly referred to as the Widom line, and is characterized by large changes in density or enthalpy, manifesting as maxima in the thermodynamic response functions. Thus, a reliable representation of the coexistence line and the Widom line is important for sub- and supercritical applications that depend on an accurate prediction of fluid properties. While it is known for subcritical pressures that nondimensionalization with the respective species critical pressures p_{cr} and temperatures T_{cr} only collapses coexistence line data for simple fluids, this approach is used for Widom lines of all fluids. However, we show here that the Widom line does not adhere to the corresponding states principle, but instead to the extended corresponding states principle. We resolve this problem in two steps. First, we propose a Widom line functional based on the Clapeyron equation and derive an analytical, species specific expression for the only parameter from the Soave-Redlich-Kwong equation of state. This parameter is a function of the acentric factor ω and compares well with experimental data. Second, we introduce the scaled reduced pressure p_{r}^{*} to replace the previously used reduced pressure p_{r}=p/p_{cr}. We show that p_{r}^{*} is a function of the acentric factor only and can thus be readily determined from fluid property tables. It collapses both subcritical coexistence line and supercritical Widom line data over a wide range of species with acentric factors ranging from -0.38 (helium) to 0.34 (water), including alkanes up to n-hexane. By using p_{r}^{*}, the extended corresponding states principle can be applied within

  18. Liquid helium

    CERN Document Server

    Atkins, K R

    1959-01-01

    Originally published in 1959 as part of the Cambridge Monographs on Physics series, this book addresses liquid helium from the dual perspectives of statistical mechanics and hydrodynamics. Atkins looks at both Helium Three and Helium Four, as well as the properties of a combination of the two isotopes. This book will be of value to anyone with an interest in the history of science and the study of one of the universe's most fundamental elements.

  19. Evaluating the Liquid Liquid Phase Transition Hypothesis of Supercoooled Water

    Science.gov (United States)

    Limmer, David; Chandler, David

    2011-03-01

    To explain the anomalous behavior of supercooled water it has been conjectured that buried within an experimentally inaccessible region of liquid water's phase diagram there exists a second critical point, which is the terminus of a first order transition line between two distinct liquid phases. The so-called liquid-liquid phase transition (LLPT) has since generated much study, though to date there is no consensus on its existence. In this talk, we will discuss our efforts to systematically study the metastable phase diagram of supercooled water through computer simulation. By employing importance-sampling techniques, we have calculated free energies as a function of the density and long-range order to determine unambiguously if two distinct liquid phases exist. We will argue that, contrary to the LLPT hypothesis, the observed phenomenology can be understood as a consequence of the limit of stability of the liquid far away from coexistence. Our results suggest that homogeneous nucleation is the cause of the increased fluctuations present upon supercooling. Further we will show how this understanding can be extended to explain experimental observations of hysteresis in confined supercooled water systems.

  20. Graphene oxide-based composite monolith as new sorbent for the on-line solid phase extraction and high performance liquid chromatography determination of ß-sitosterol in food samples.

    Science.gov (United States)

    Cui, Beijiao; Guo, Bin; Wang, Huimin; Zhang, Doudou; Liu, Haiyan; Bai, Ligai; Yan, Hongyuan; Han, Dandan

    2018-08-15

    A composite monolithic column was prepared by redox initiation method for the on-line purification and enrichment of β-sitosterol, in which graphene oxide (GO) was embedded. The obtained monolithic column was characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption isotherm measurement, which indicated that the monolith possessed characteristics of porous structure and high permeability. Under the optimum conditions for extraction and determination, the calibration equation was y = 47.92 × -0.1391; the linear range was 0.008-1.0 mg mL -1 ; the linear regression coefficient was 0.998; the limit of detection (LOD) is 2.4 μg mL -1 ; the limit of quantitation (LOQ) was 8 μg mL -1 ; precisions for intra-day and inter-day assays presented as relative standard deviations were less than 4.3% and 6.8%, respectively. Under the selective conditions, the enrichment factor of the method was 119. The recovery was in the range of 80.40-98.00%. Moreover, the adsorption amount of the monolith was compared with silica gel-C18 adsorbent and the monolith without graphene oxide being embedded. The polymerization monolithic column showed high selectivity and good permeability, and it was successfully used as on-line solid-phase extraction (SPE) column for determination of β-sitosterol in edible oil. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The U-line line balancing problem

    NARCIS (Netherlands)

    Miltenburg, G.J.; Wijngaard, J.

    1994-01-01

    The traditional line balancing (LB) problem considers a production line in which stations are arranged consecutively in a line. A balance is determined by grouping tasks into stations while moving forward (or backward) through a precedence network. Recently many production lines are being arranged

  2. Internal audit consider the implications.

    Science.gov (United States)

    Baumgartner, Grant D; Hamilton, Angela

    2004-06-01

    Internal audit can not only allay external and internal concerns about appropriateness of business operations, but also help improve efficiency and the bottom line. To get an internal audit function under way, healthcare organizations need to obtain board buy-in, form an audit committee of the board, determine resources needed, perform a risk assessment, and develop an internal audit plan.

  3. Countercurrent chromatography separation of saponins by skeleton type from Ampelozizyphus amazonicus for off-line ultra-high-performance liquid chromatography/high resolution accurate mass spectrometry analysis and characterisation.

    Science.gov (United States)

    de Souza Figueiredo, Fabiana; Celano, Rita; de Sousa Silva, Danila; das Neves Costa, Fernanda; Hewitson, Peter; Ignatova, Svetlana; Piccinelli, Anna Lisa; Rastrelli, Luca; Guimarães Leitão, Suzana; Guimarães Leitão, Gilda

    2017-01-20

    Ampelozizyphus amazonicus Ducke (Rhamnaceae), a medicinal plant used to prevent malaria, is a climbing shrub, native to the Amazonian region, with jujubogenin glycoside saponins as main compounds. The crude extract of this plant is too complex for any kind of structural identification, and HPLC separation was not sufficient to resolve this issue. Therefore, the aim of this work was to obtain saponin enriched fractions from the bark ethanol extract by countercurrent chromatography (CCC) for further isolation and identification/characterisation of the major saponins by HPLC and MS. The butanol extract was fractionated by CCC with hexane - ethyl acetate - butanol - ethanol - water (1:6:1:1:6; v/v) solvent system yielding 4 group fractions. The collected fractions were analysed by UHPLC-HRMS (ultra-high-performance liquid chromatography/high resolution accurate mass spectrometry) and MS n . Group 1 presented mainly oleane type saponins, and group 3 showed mainly jujubogenin glycosides, keto-dammarane type triterpene saponins and saponins with C 31 skeleton. Thus, CCC separated saponins from the butanol-rich extract by skeleton type. A further purification of group 3 by CCC (ethyl acetate - ethanol - water (1:0.2:1; v/v)) and HPLC-RI was performed in order to obtain these unusual aglycones in pure form. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Separation of seven arsenic compounds by high performance liquid chromatography with on-line detection by hydrogen-argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, Erik Huusfeldt; Pritzl, G.

    1992-01-01

    -to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...... of mixtures of arsenic standards into the HPLC system were: arsenite, As(III) 1.1; arsenate, As(V) 1.4; MMA 1.4; DMA 0.7; AsB 0.3; AsC 0.5; and the TMAs 0.4. The HPLC-AAS system was used for the analysis of arsenic species in aqueous extracts of soil samples from a polluted land site. Only arsenate was found...

  5. Simultaneous analysis of gemfibrozil, morphine, and its two active metabolites in different mouse brain structures using solid-phase extraction with ultra-high performance liquid chromatography and tandem mass spectrometry with a deuterated internal standard.

    Science.gov (United States)

    Yang, Zizhao; Wang, Lu; Xu, Mingcheng; Gu, Jingkai; Yu, Lushan; Zeng, Su

    2016-06-01

    A rapid and sensitive bioassay was established and validated to simultaneously determine gemfibrozil, morphine, morphine-3β-glucuronide, and morphine-6β-glucuronide in mouse cerebrum, epencephalon, and hippocampus based on ultra-high performance liquid chromatography and tandem mass spectrometry. The deuterated internal standard, M6G-d3, was mixed with the prepared samples at 10 ng/mL as the final concentration. The samples were transferred into the C18 solid-phase extraction columns with gradient elution for solid-phase extraction. The mobile phase consisted of methanol and 0.05% formic acid (pH 3.2). Multiple reaction monitoring has been applied to analyze gemfibrozil (m/z 249.0 → 121.0) in anion mode, and M6G-d3 (m/z 465.1 → 289.1), morphine (m/z 286.0 → 200.9), and M3G and M6G (m/z 462.1 → 286.1) in the positive ion mode. The method has a linear calibration range from 0.05 to 10 ng for gemfibrozil, morphine, and M3G and M6G with correlation coefficients >0.993. The lower limit of quantitation for all four analytes was 0.05 ng/mL, relative standard deviation of intra- and interday precision was less than 10.5%, and the relative error of accuracy was from -8.2 to 8.3% at low, medium, and high concentrations for all the analytes. In conclusion, gemfibrozil can influence the morphine antinociception after coronary heart disease induced chronic angina by the change in one of morphine metabolites', M3G, distribution in mouse brain. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

    Science.gov (United States)

    Hartwig, Jason W.; Chato, David J.; McQuillen, J. B.; Vera, J.; Kudlac, M. T.; Quinn, F. D.

    2013-01-01

    This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

  7. Liquid electrode

    Science.gov (United States)

    Ekechukwu, A.A.

    1994-07-05

    A dropping electrolyte electrode is described for use in electrochemical analysis of non-polar sample solutions, such as benzene or cyclohexane. The liquid electrode, preferably an aqueous salt solution immiscible in the sample solution, is introduced into the solution in dropwise fashion from a capillary. The electrolyte is introduced at a known rate, thus, the droplets each have the same volume and surface area. The electrode is used in making standard electrochemical measurements in order to determine properties of non-polar sample solutions. 2 figures.

  8. Liquid diode

    International Nuclear Information System (INIS)

    1976-01-01

    The liquid diode is designed for a flowmeter chamber which has an inlet and an outlet duct, and a flow chamber with a cross-section which is greater than inlet. In the space between the inlet and outlet are two screens with a number of spheres, which may be of different sizes and weights. The screen on the inlet side is smaller than that at the outlet, so that the spheres are able to block the inlet under reverse flow conditions, but do not block the outlet. The system functions as a non-return valve. (G.C.)

  9. (Liquid + liquid) equilibria for (water + 1-propanol or acetone + β-citronellol) at different temperatures

    International Nuclear Information System (INIS)

    Li, Hengde; Han, Yongtao; Huang, Cheng; Yang, Chufen

    2015-01-01

    Graphical abstract: (Liquid + liquid) equilibrium data for systems composed of β-citronellol and aqueous 1-propanol or acetone are presented. Distribution ratios of 1-propanol and acetone in the mixtures are examined. The effect of the temperature on the ternary (liquid + liquid) equilibria is evaluated and discussed. - Highlights: • Ternary (liquid + liquid) equilibria containing β-citronellol are presented. • Distribution ratios of 1-propanol and acetone in the mixtures are examined. • The effect on the temperature of the systems is evaluated and discussed. - Abstract: On this paper, experimental (liquid + liquid) equilibrium (LLE) results are presented for systems composed of β-citronellol and aqueous 1-propanol or acetone. To evaluate the phase separation properties of β-citronellol in aqueous mixtures, LLE values for the ternary systems (water + 1-propanol + β-citronellol) and (water + acetone + β-citronellol) were determined with a tie-line method at T = (283.15, 298.15, and 313.15 ± 0.02) K and atmospheric pressure. The reliability of the experimental tie-lines was verified by the Hand and Bachman equations. Ternary phase diagrams, distribution ratios of 1-propanol and acetone in the mixtures are shown. The effect of the temperature on the ternary (liquid + liquid) equilibria was examined and discussed. The experimental LLE values were satisfactorily correlated by extended UNIQUAC and modified UNIQUAC models

  10. Low-Level Burial Grounds dangerous waste permit application: Request for exemption from lined trench requirements and from land disposal restrictions for residual liquid at 218-E-12B Burial Ground Trench 94

    International Nuclear Information System (INIS)

    1992-10-01

    This document has been prepared and is being submitted to the respective agencies to satisfy three objectives of the US Department of Energy (DOE) Richland Field Office (DOE-RL) concerning Trench 94 of the 218-E-12B Burial Ground. The 218-E-12B Burial Ground is located in the 200 East Area of the Hanford Facility. Figure 1-1 shows the general location of the Hanford Site. The 218-E-12B Burial Ground is one of eight burial grounds included in the Low-Level Burial Grounds (LLBG), a treatment, storage and/or disposal (TSD) unit. Decommissioned, defueled naval submarine reactor compartments (SRCs) contain radioactivity caused by exposure of structural components to neutrons during normal operation of the submarines. After all the alternatives were evaluated in the US Department of the Navy 1984 environmental impact statement (EIS) (USN 1984), land burial of the SRCs was selected as the preferred disposal option. The SRCs currently are sent to Trench 94 of the 218-E-12B Burial Ground. In addition to radioactivity, the SRCs disposed in. The DOE-RL's three objectives in preparing and submitting this document are as follows. Request from Ecology an exemption from dangerous waste landfill liner and leachate collection and removal system (hereinafter referred to as liner/leachate system) requirements for Trench 94 of the 218-E-12B Burial Ground. Petition Ecology to exempt residual liquid in the SRCs from land disposal restrictions. Obtain EPA Region 10 review and comment on the request to Ecology for exemption from liner/leachate system requirements

  11. From Funding Liquidity to Market Liquidity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens; Lund, Jesper; Gyntelberg, Jacob

    This paper shows empirically that funding liquidity drives market liquidity. As it becomes harder to secure term funding in the money markets, liquidity deteriorates in the Danish bond market. We show that the first principal component of bond market liquidity is driven by the market makers...... for other European government bonds using MTS data. The findings suggest that regulatory bond based liquidity buffers for banks will have limited effectiveness....

  12. Power line communications theory and applications for narrowband and broadband communications over power lines

    CERN Document Server

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  13. International Trade. International Business

    OpenAIRE

    Мохнюк, А. М.; Mokhniuk, A. M.

    2015-01-01

    Work programme of the study course “International Trade. International Business” was prepared in accordance with educational and vocational training program for bachelors of training direction 6.030601 “Management”.

  14. Path-integral and Ornstein-Zernike study of quantum fluid structures on the crystallization line

    International Nuclear Information System (INIS)

    Sesé, Luis M.

    2016-01-01

    Liquid neon, liquid para-hydrogen, and the quantum hard-sphere fluid are studied with path integral Monte Carlo simulations and the Ornstein-Zernike pair equation on their respective crystallization lines. The results cover the whole sets of structures in the r-space and the k-space and, for completeness, the internal energies, pressures and isothermal compressibilities. Comparison with experiment is made wherever possible, and the possibilities of establishing k-space criteria for quantum crystallization based on the path-integral centroids are discussed. In this regard, the results show that the centroid structure factor contains two significant parameters related to its main peak features (amplitude and shape) that can be useful to characterize freezing.

  15. Path-integral and Ornstein-Zernike study of quantum fluid structures on the crystallization line

    Energy Technology Data Exchange (ETDEWEB)

    Sesé, Luis M., E-mail: msese@ccia.uned.es [Departamento de Ciencias y Técnicas Fisicoquímicas, Universidad Nacional de Educación a Distancia, Paseo Senda del Rey 9, 28040 Madrid (Spain)

    2016-03-07

    Liquid neon, liquid para-hydrogen, and the quantum hard-sphere fluid are studied with path integral Monte Carlo simulations and the Ornstein-Zernike pair equation on their respective crystallization lines. The results cover the whole sets of structures in the r-space and the k-space and, for completeness, the internal energies, pressures and isothermal compressibilities. Comparison with experiment is made wherever possible, and the possibilities of establishing k-space criteria for quantum crystallization based on the path-integral centroids are discussed. In this regard, the results show that the centroid structure factor contains two significant parameters related to its main peak features (amplitude and shape) that can be useful to characterize freezing.

  16. 26 CFR 1.167(b)-1 - Straight line method.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Straight line method. 1.167(b)-1 Section 1.167(b... Straight line method. (a) In general. Under the straight line method the cost or other basis of the... may be reduced to a percentage or fraction. The straight line method may be used in determining a...

  17. Development of a two-dimensional high-performance liquid chromatography system coupled with on-line reduction as a new efficient analytical method of 3-nitrobenzanthrone, a potential human carcinogen.

    Science.gov (United States)

    Hasei, Tomohiro; Nakanishi, Haruka; Toda, Yumiko; Watanabe, Tetsushi

    2012-08-31

    3-Nitrobenzanthrone (3-NBA) is an extremely strong mutagen and carcinogen in rats inducing squamous cell carcinoma and adenocarcinoma. We developed a new sensitive analytical method, a two-dimensional HPLC system coupled with on-line reduction, to quantify non-fluorescent 3-NBA as fluorescent 3-aminobenzanthrone (3-ABA). The two-dimensional HPLC system consisted of reversed-phase HPLC and normal-phase HPLC, which were connected with a switch valve. 3-NBA was purified by reversed-phase HPLC and reduced to 3-ABA with a catalyst column, packed with alumina coated with platinum, in ethanol. An alcoholic solvent is necessary for reduction of 3-NBA, but 3-ABA is not fluorescent in the alcoholic solvent. Therefore, 3-ABA was separated from alcohol and impurities by normal-phase HPLC and detected with a fluorescence detector. Extracts from surface soil, airborne particles, classified airborne particles, and incinerator dust were applied to the two-dimensional HPLC system after clean-up with a silica gel column. 3-NBA, detected as 3-ABA, in the extracts was found as a single peak on the chromatograms without any interfering peaks. 3-NBA was detected in 4 incinerator dust samples (n=5). When classified airborne particles, that is, those 7.0 μm in size, were applied to the two-dimensional HPLC system after purified using a silica gel column, 3-NBA was detected in those particles with particle sizes NBA in airborne particles and the detection of 3-NBA in incinerator dust. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. First-line selective internal radiotherapy plus chemotherapy versus chemotherapy alone in patients with liver metastases from colorectal cancer (FOXFIRE, SIRFLOX, and FOXFIRE-Global): a combined analysis of three multicentre, randomised, phase 3 trials.

    Science.gov (United States)

    Wasan, Harpreet S; Gibbs, Peter; Sharma, Navesh K; Taieb, Julien; Heinemann, Volker; Ricke, Jens; Peeters, Marc; Findlay, Michael; Weaver, Andrew; Mills, Jamie; Wilson, Charles; Adams, Richard; Francis, Anne; Moschandreas, Joanna; Virdee, Pradeep S; Dutton, Peter; Love, Sharon; Gebski, Val; Gray, Alastair; van Hazel, Guy; Sharma, Ricky A

    2017-09-01

    Data suggest selective internal radiotherapy (SIRT) in third-line or subsequent therapy for metastatic colorectal cancer has clinical benefit in patients with colorectal liver metastases with liver-dominant disease after chemotherapy. The FOXFIRE, SIRFLOX, and FOXFIRE-Global randomised studies evaluated the efficacy of combining first-line chemotherapy with SIRT using yttrium-90 resin microspheres in patients with metastatic colorectal cancer with liver metastases. The studies were designed for combined analysis of overall survival. FOXFIRE, SIRFLOX, and FOXFIRE-Global were randomised, phase 3 trials done in hospitals and specialist liver centres in 14 countries worldwide (Australia, Belgium, France, Germany, Israel, Italy, New Zealand, Portugal, South Korea, Singapore, Spain, Taiwan, the UK, and the USA). Chemotherapy-naive patients with metastatic colorectal cancer (WHO performance status 0 or 1) with liver metastases not suitable for curative resection or ablation were randomly assigned (1:1) to either oxaliplatin-based chemotherapy (FOLFOX: leucovorin, fluorouracil, and oxaliplatin) or FOLFOX plus single treatment SIRT concurrent with cycle 1 or 2 of chemotherapy. In FOXFIRE, FOLFOX chemotherapy was OxMdG (oxaliplatin modified de Gramont chemotherapy; 85 mg/m 2 oxaliplatin infusion over 2 h, L-leucovorin 175 mg or D,L-leucovorin 350 mg infusion over 2 h, and 400 mg/m 2 bolus fluorouracil followed by a 2400 mg/m 2 continuous fluorouracil infusion over 46 h). In SIRFLOX and FOXFIRE-Global, FOLFOX chemotherapy was modified FOLFOX6 (85 mg/m 2 oxaliplatin infusion over 2 h, 200 mg leucovorin, and 400 mg/m 2 bolus fluorouracil followed by a 2400 mg/m 2 continuous fluorouracil infusion over 46 h). Randomisation was done by central minimisation with four factors: presence of extrahepatic metastases, tumour involvement of the liver, planned use of a biological agent, and investigational centre. Participants and investigators were not masked to treatment. The primary

  19. International Union of Theoretical and Applied Mechanics: Symposium on Adiabatic Waves in liquid-Vapor Systems Held at Goettingen (Germany, F.R.) on 28 August-1 September 1989. Abstracts of the Contributed Papers

    Science.gov (United States)

    1989-09-01

    THE LIQUID- VAPOR CRITICAL POINT" P.A. Thompson, J.E. Shepherd, H.J. Cho, S.Can Gulen (Troy). Non-euilibrium in dinamic systems , critical phenomena...IN LIQUID-VAPOR SYSTEMS G~ttingen: 28. August - 1. September 1989 Chairmen: Gerd E.A. Meier & Philip A. Thompson Secretary: Tomasz A. Kowalewski...is a great pleasure to welcome you on behalf of the Organizing Committee to the IUTAM Symposium on Adiabatic Waves in Liquid Vapor Systems . We are

  20. Dual Symmetry in Bent-Core Liquid Crystals and Unconventional Superconductors

    Directory of Open Access Journals (Sweden)

    Vladimir Lorman

    2010-01-01

    Full Text Available We extend the Landau theory of bent-core mesophases and d-wave high-Tc superconductors by considering additional secondary pseudo-proper order parameters. These systems exhibit a remarkable analogy relating their symmetry groups, lists of phases, and an infinite set of physical tensors. This analogy lies upon an internal dual structure shared by the two theories. We study the dual operator transforming rotations into translations in liquid crystals, and gauge symmetries into rotations in superconductors. It is used to classify the bent-core line defects, and to analyze the electronic gap structure of lamellar d-wave superfluids.