WorldWideScience

Sample records for internal fe pool

  1. Heat transfer from internally heated hemispherical pools

    International Nuclear Information System (INIS)

    Gabor, J.D.; Ellsion, P.G.; Cassulo, J.C.

    1980-01-01

    Experiments were conducted on heat transfer from internally heated ZnSO 4 -H 2 O pools to the walls of hemispherical containers. This experimental technique provides data for a heat transfer system that has to date been only theoretically treated. Three different sizes of copper hemispherical containers were used: 240, 280, 320 mm in diameter. The pool container served both as a heat transfer surface and as an electrode. The opposing electrode was a copper disk, 50 mm in diameter located at the top of the pool in the center. The top surface of the pool was open to the atmosphere

  2. Iron deficiency in chronic heart failure : An international pooled analysis

    NARCIS (Netherlands)

    Klip, IJsbrand T.; Comin-Colet, Josep; Voors, Adriaan A.; Ponikowski, Piotr; Enjuanes, Cristina; Banasiak, Waldemar; Lok, Dirk J.; Rosentryt, Piotr; Torrens, Ainhoa; Polonski, Lech; van Veldhuisen, Dirk J.; van der Meer, Peter; Jankowska, Ewa A.

    Background Iron deficiency (ID) is an emerging problem in patients with chronic heart failure (HF) and can be a potential therapeutic target. However, not much is known about the prevalence, predictors, and prognosis of ID in patients with chronic HF. Methods In an international pooled cohort

  3. Impact of Fe(III)-OM complexes and Fe(III) polymerization on SOM pools reactivity under different land uses

    Science.gov (United States)

    Giannetta, B.; Plaza, C.; Zaccone, C.; Siebecker, M. G.; Rovira, P.; Vischetti, C.; Sparks, D. L.

    2017-12-01

    Soil organic matter (SOM) protection and long-term accumulation are controlled by adsorption to mineral surfaces in different ways, depending on its molecular structure and pedo-climatic conditions. Iron (Fe) oxides are known to be key regulators of the soil carbon (C) cycle, and Fe speciation in soils is highly dependent on environmental conditions and chemical interactions with SOM. However, the molecular structure and hydrolysis of Fe species formed in association with SOM is still poorly described. We hypothesize the existence of two pools of Fe which interact with SOM: mononuclear Fe(III)-SOM complexes and precipitated Fe(III) hydroxides. To verify our hypothesis, we investigated the interactions between Fe(III) and physically isolated soil fractions by means of batch experiments at pH 7. Specifically, we examined the fine silt plus clay (FSi+C) fraction, obtained by ultrasonic dispersion and wet sieving. The soil samples spanned several land uses, including coniferous forest (CFS), grassland (GS), technosols (TS) and agricultural (AS) soils. Solid phase products and supernatants were analyzed for C and Fe content. X-ray diffraction (XRD) and Brunauer-Emmett-Teller (BET) analysis were also performed. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) was used to assess the main C functional groups involved in C complexation and desorption experiments. Preliminary linear combination fitting (LCF) of Fe K-edge extended X-ray absorption fine structure (EXAFS) spectra suggested the formation of ferrihydrite-like polymeric Fe(III) oxides in reacted CFS and GS samples, with higher C and Fe concentration. Conversely, mononuclear Fe(III) OM complexes dominated the speciation for TS and AS samples, characterized by lower C and Fe concentration, inhibiting the hydrolysis and polymerization of Fe (III). This approach will help revealing the mechanisms by which SOM pools can control Fe(III) speciation, and will elucidate how both Fe

  4. Heat transfer from internally-heated molten UO2 pools

    International Nuclear Information System (INIS)

    Stein, R.P.; Baker, L. Jr.; Gunther, W.H.; Cook, C.

    1978-01-01

    Experimental measurements of heat transfer from internally heated pools of molten UO 2 have been obtained for two cell sizes: 10 cm x 10 cm and 20 cm x 20 cm. The experiments with the large cell have supported a previous conclusion from early small data that the measured downward heat fluxes are higher than would be expected on the basis of considerations of thermal convection. A convective model underpredicts the downward heat fluxes by a factor of 2.5 to 4.5 for all but one early experiment. Arbitrary assumptions of increased thermal conductivity do not account for the discrepancy. A single model based on internal thermal radiation heat transfer is able to account for the high values. The model uses the optically thick Rosseland approximation. Because of this, it is tentatively concluded that thermal radiation plays a dominant role in controlling the heat transfer from internally heated molted fuel

  5. Internal exposure by natural radiation and decontamination of swimming pool

    International Nuclear Information System (INIS)

    Seki, Hideyuki

    2012-01-01

    This explanation concerns the scientific knowledge and finding of the title subjects for general public to understand their present radiation environment, id est (i.e.), at about 1 year after the Fukushima Daiichi Power Plant Accident (FDPPA). The first described is the world history of radiation exposure, where A-bomb explosion in Hiroshima and Nagasaki, Three Mile Island Power Plant Accident and Chernobyl Accident are told about their teachings and about internal nuclides at FDPPA: the author points out the natural high abundance of K-40 in contrast to the release of I-131, and Cs-137/-134 in the accident. The second is described about the effect of radiations on human cells, where characteristics, measurements, unit and their derived radionuclides of alpha, beta and gamma rays are explained together with their biological influences. Also explained are hydroxy-radical formation by alpha and beta rays in the internal exposure, and comparison of external photons, gamma and more risky ultraviolet rays. Third, the author mentions about man's natural functions to protect radiation hazard. Presented are an easy calculation and a comparison of K-40 and Cs-137 contents (weight and Bq) in the body and in the swimming pool with reference to Chernobyl standards. Internal exposure by natural radionuclides like K-40 and others, is also calculated, which is found equivalent to 0.29 mSv/y based on about 5,630 Bq/60 kg body weight. Finally, explained are the knowledge and practice of decontamination, where various adsorbents like zeolite (molecular sieve), ion exchanger, charcoal and natural zeolites (alumino-silicate) are compared and the last agent, clay easily and economically available, is recommended for decontamination. Clay material is said to adsorb 87% of Cs-137 at as low level as 750 mg/L and the author has an experience to use it successfully for decontamination of the pool. Importantly, the radioactivity of the resultant sludge should not exceed 8,000 Bq/kg. (T.T.)

  6. Effects of a FeCrAl layer fabricated by sputtering process on pool boiling critical heat flux

    International Nuclear Information System (INIS)

    Seo, Gwang Hyeok; Son, Hong Hyun; Jeun, Gyoodong; Kim, Sung Joong

    2016-01-01

    The thermal safety margin of a FeCrAl-layered heater was investigated measuring pool boiling critical heat flux (CHF). Boiling experiments were conducted in a pool of deionized water at atmospheric pressure. For a comparison work, bare and FeCrAl-layered heater samples were prepared. The sputtering technique was employed to fabricate the FeCrAl layer. It was confirmed that the key sputtering parameters on the surface structure were substrate temperature and deposition time. As compared to the bare sample, surface wettability and roughness increased. Higher values of the surface roughness were observed at temperatures of 150degC and 600degC. The FeCrAl-layered heaters showed improved CHF up to ∼40%. The highest enhancement of 42% was observed for the heater sample fabricated at a substrate temperature of 150degC. With employing recent CHF models that incorporate the surface effects, it was evaluated that increased roughness at the micrometer scale mainly contributed to the CHF enhancement. Furthermore, visual observations showed at least 2 msec reduction in the rewetting times for the FeCrAl-layered heaters, and the improved CHF may be attributed to the suppressed hot dry spots due to the rewetting phenomena. (author)

  7. Production of molten UO2 pools by internal heating: apparatus and preliminary experimental heat transfer results

    International Nuclear Information System (INIS)

    Chasanov, M.G.; Gunther, W.H.; Baker, L. Jr.

    1977-01-01

    The capability for removal of heat from a pool of molten fuel under postaccident conditions is an important consideration in liquid-metal fast breeder reactor safety analysis. No experimental data for pool heat transfer from molten UO 2 under conditions simulating internal heat generation by fission product decay have been reported previously in the literature. An apparatus to provide such data was developed and used to investigate heat transfer from pools containing up to 7.5 kg of UO 2 ; the internal heat generation rates and pool depths attained cover most of the ranges of interest for postaccident heat removal analysis. It was also observed in these studies that the presence of simulated fission products corresponding to approximately 150,000 kW-day/kg burnup had no significant effect on the observed heat transfer

  8. Cannabis smoking and lung cancer risk: Pooled analysis in the International Lung Cancer Consortium

    OpenAIRE

    Zhang, L.R.; Morgenstern, H.; Greenland, S.; Chang, S.C.; Lazarus, P.; Teare, M.D.; Woll, P.J.; Orlow, I.; Cox, B.; Brhane, Y.; Liu, G.; Hung, R.J.

    2015-01-01

    To investigate the association between cannabis smoking and lung cancer risk, data on 2,159 lung cancer cases and 2,985 controls were pooled from 6 case-control studies in the US, Canada, UK, and New Zealand within the International Lung Cancer Consortium. Study-specific associations between cannabis smoking and lung cancer were estimated using unconditional logistic regression adjusting for sociodemographic factors, tobacco smoking status and pack-years; odds-ratio estimates were pooled usin...

  9. Redox reactions of [FeFe]-hydrogenase models containing an internal amine and a pendant phosphine.

    Science.gov (United States)

    Zheng, Dehua; Wang, Mei; Chen, Lin; Wang, Ning; Sun, Licheng

    2014-02-03

    A diiron dithiolate complex with a pendant phosphine coordinated to one of the iron centers, [(μ-SCH2)2N(CH2C6H4-o-PPh2){Fe2(CO)5}] (1), was prepared and structurally characterized. The pendant phosphine is dissociated together with a CO ligand in the presence of excess PMe3, to afford [(μ-SCH2)2N(CH2C6H4-o-PPh2){Fe(CO)2(PMe3)}2] (2). Redox reactions of 2 and related complexes were studied in detail by in situ IR spectroscopy. A series of new Fe(II)Fe(I) ([3](+) and [6](+)), Fe(II)Fe(II) ([4](2+)), and Fe(I)Fe(I) (5) complexes relevant to Hox, Hox(CO), and Hred states of the [FeFe]-hydrogenase active site were detected. Among these complexes, the molecular structures of the diferrous complex [4](2+) with the internal amine and the pendant phosphine co-coordinated to the same iron center and the triphosphine diiron complex 5 were determined by X-ray crystallography. To make a comparison, the redox reactions of an analogous complex, [(μ-SCH2)2N(CH2C6H5){Fe(CO)2(PMe3)}2] (7), were also investigated by in situ IR spectroscopy in the absence or presence of extrinsic PPh3, which has no influence on the oxidation reaction of 7. The pendant phosphine in the second coordination sphere makes the redox reaction of 2 different from that of its analogue 7.

  10. Analysis of natural convection heat transfer and flows in internally heated stratified liquid pools

    International Nuclear Information System (INIS)

    Gubaidullin, A.A. Jr.; Dinh, T.N.; Sehgal, B.R.

    1999-01-01

    In this paper, natural convection flows and heat transfer in a liquid pool, with two superposed immiscible fluid layers, are analyzed. The objective of the study is to examine the effect of interfacial hydrodynamics and to develop a method which enables energy splitting to be evaluated in a stratified liquid pool. The thermal convection, with and without an internal heat source, in a rectangular cavity with different pairs of fluids was numerically simulated by a CFD code FLOW-3D. It was found that the code performs very well for prediction of heat transfer coefficients for different conditions. The hydrodynamic coupling between immiscible layers was found to have minor, if any, impact on the natural convection heat transfer for the conditions examined. Calculated results were used to develop, and validate, a new correlation for energy splitting and for heat transfer in stratified liquid pools

  11. An international pooled analysis for obtaining a benchmark dose for environmental lead exposure in children

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Esben; Bellinger, David; Lanphear, Bruce

    2013-01-01

    Lead is a recognized neurotoxicant, but estimating effects at the lowest measurable levels is difficult. An international pooled analysis of data from seven cohort studies reported an inverse and supra-linear relationship between blood lead concentrations and IQ scores in children. The lack...... of a clear threshold presents a challenge to the identification of an acceptable level of exposure. The benchmark dose (BMD) is defined as the dose that leads to a specific known loss. As an alternative to elusive thresholds, the BMD is being used increasingly by regulatory authorities. Using the pooled data...... yielding lower confidence limits (BMDLs) of about 0.1-1.0 μ g/dL for the dose leading to a loss of one IQ point. We conclude that current allowable blood lead concentrations need to be lowered and further prevention efforts are needed to protect children from lead toxicity....

  12. Internalization and cellular pools of never growth factor in pheochromocytoma (PC12) cells

    International Nuclear Information System (INIS)

    Neet, K.E.; Kasaian, M.

    1987-01-01

    Nerve Growth Factor (NGF) binds to a cell surface receptor on responsive neuronal cells to initiate cell maintenance and/or differentiation regimes. The purpose of these studies was to define quantitatively the fate of NGF in PC12 cells with respect to various cellular compartments in a single series of biochemical experiments. Different binding methodologies were evaluated in suspension and on plates. 50 pM 125 I-NGF was bound to rat PC12 cells in suspension for 30 min at 37 0 , followed by various methods and combinations of methods to remove subsets of bound ligand. Distinction could be made between NGF bound to fast vs. slow cell surface receptors, NGF bound to slow receptors at the cell surface vs. cell interior, and detergent-soluble vs. cytoskeletally-attached NGF. These treatments defined the relative size of five pools, including the fast receptor (65%), two intracellular compartments (12% and 3%) susceptible to nonionic detergent, and a detergent-stable intracellular pool of ligand (16%). At 37 0 the cold chase stable and the acid stable pools were about the same size because of rapid internalization, but the slow receptor was measurable at 4 0 . Inhibitors were used to define the route of NGF through the cell from the plasma membrane to degradation. Chloroquine caused accumulation of NGF only in pools that were not associated with the cytoskeleton, implicating this compartment in supplying ligand to the lysosome. Results with cytochalasin B and colchicine and suggested both microfilament and microtubule pathways in NGF degradation. A model for the movement of NGF through the cell was developed based on these observations

  13. An internal core catcher for a pool L.M.F.B.R. and connected studies

    International Nuclear Information System (INIS)

    Le Rigoleur, C.; Kayser, G.

    1979-01-01

    This paper describes an internal core catcher for a pool LMFBR. Problems related to retention of debris are studied: downward progression of debris from the core to the core catcher, debris bed formation, heat transfer below the core catcher plate and to the main vessel, mechanical resistance. These results are used to estimate the performances of the internal core catcher for a given core melt-down-accident. It is seen that for a uniform thickness layer on the core catcher the retention capabilities are satisfactory. Then the problem of a heap of debris is approached. Dryout is studied. Uncertainties related to the bed characteristics and problems of extended dryout beds are put forward

  14. Internal Friction of Austenitic Fe-Mn-C-Al Alloys

    Science.gov (United States)

    Lee, Young-Kook; Jeong, Sohee; Kang, Jee-Hyun; Lee, Sang-Min

    2017-12-01

    The internal friction (IF) spectra of Fe-Mn-C-Al alloys with a face-centered-cubic (fcc) austenitic phase were measured at a wide range of temperature and frequency ( f) to understand the mechanisms of anelastic relaxations occurring particularly in Fe-Mn-C twinning-induced plasticity steels. Four IF peaks were observed at 346 K (73 °C) (P1), 389 K (116 °C) (P2), 511 K (238 °C) (P3), and 634 K (361 °C) (P4) when f was 0.1 Hz. However, when f increased to 100 Hz, whereas P1, P2, and P4 disappeared, only P3 remained without the change in peak height, but with the increased peak temperature. P3 matches well with the IF peak of Fe-high Mn-C alloys reported in the literature. The effects of chemical composition and vacancy (v) on the four IF peaks were also investigated using various alloys with different concentrations of C, Mn, Al, and vacancy. As a result, the defect pair responsible for each IF peak was found as follows: a v-v pair for P1, a C-v pair for P2, a C-C pair for P3, and a C-C-v complex (major effect) + a Mn-C pair (minor effect) for P4. These results showed that the IF peaks of Fe-Mn-C-Al alloys reported previously were caused by the reorientation of C in C-C pairs, not by the reorientation of C in Mn-C pairs.

  15. Conjugated heat transfer of natural convection in pool with internal heat sources and convection in the tube

    International Nuclear Information System (INIS)

    Li Longjian; Liu Hongtao; Cui Wenzhi

    2007-01-01

    The conjugated heat transfer of natural convection in pool with internal heat source and the forced convection in the tube was analyzed, and the corresponding three-dimensional physical and mathematical model was proposed. A control volume based finite element method was employed to solve numerically the problem. The computations were performed for different internal heat source intensity of the pool and the different flow velocity in the tube. The computed heat transfer coefficients on the inner and outer wall showed well consistency of those calculated with the empirical correlations. Compared with the measured total heat transfer coefficients between the fluids in and out of the tube, the computed ones showed also the well consistency, which implied that the numerical model proposed in this paper was reliable. The research results revealed that the total heat transfer coefficients between the fluids were strongly affected by the internal heat source intensity of the pool liquid and the flow velocity in the tube. (authors)

  16. International pooling of operators' funds: an option to increase the amount of financial security to cover nuclear liability?

    International Nuclear Information System (INIS)

    Pelzer, N.

    2007-01-01

    This paper aims at answering the question whether international pooling of operators funds could open a viable avenue to complement financial security provided by insurance and thus to either fill gaps in insurance coverage or increase amount of compensation for nuclear damage. (author)

  17. In-Home Coal and Wood Use and Lung Cancer Risk: A Pooled Analysis of the International Lung Cancer Consortium

    OpenAIRE

    Hosgood, H. Dean; Boffetta, Paolo; Greenland, Sander; Lee, Yuan-Chin Amy; McLaughlin, John; Seow, Adeline; Duell, Eric J.; Andrew, Angeline S.; Zaridze, David; Szeszenia-Dabrowska, Neonila; Rudnai, Peter; Lissowska, Jolanta; Fabiánová, Eleonóra; Mates, Dana; Bencko, Vladimir

    2010-01-01

    Background Domestic fuel combustion from cooking and heating is an important public health issue because roughly 3 billion people are exposed worldwide. Recently, the International Agency for Research on Cancer classified indoor emissions from household coal combustion as a human carcinogen (group 1) and from biomass fuel (primarily wood) as a probable human carcinogen (group 2A). Objectives We pooled seven studies from the International Lung Cancer Consortium (5,105 cases and 6,535 controls)...

  18. Strategies to increase the donor pool and access to kidney transplantation: an international perspective

    DEFF Research Database (Denmark)

    Maggiore, U.; Oberbauer, R.; Pascual, J.

    2015-01-01

    In this position article, DESCARTES (Developing Education Science and Care for Renal Transplantation in European States) board members describe the current strategies aimed at expanding living and deceased donor kidney pools. The article focuses on the recent progress in desensitization and kidney...

  19. Numerical Investigation of Turbulent Natural Convection Heat Transfer in an Internally-Heated Melt Pool and Metallic Layer

    International Nuclear Information System (INIS)

    Nourgaliev, R.R.; Dinh, A.T.; Dinh, T.N.; Sehgal, B.R.

    1999-01-01

    This paper presents results of numerical investigation of turbulent natural convection in an internally-heated oxidic pool, and in a metallic layer heated from below and cooled from top and sidewalls. Emphasis is placed upon applicability of the existing heat transfer correlations (obtained from simulant-material experiments) in assessments of a prototypic severe reactor accident. The objectives of this study are (i) to improve the current understanding of the physics of unstably stratified flows, and (ii) to reduce uncertainties associated with modeling and assessment of natural convection heat transfer in the above configuration. Prediction capabilities of different turbulence modeling approaches are first examined and discussed, based on extensive results of numerical investigations performed by present authors. Findings from numerical modeling of turbulent natural convection flow and heat transfer in melt pools and metallic layers are then described. (authors)

  20. Psychometric Properties of the International Personality Item Pool Big-Five Personality Questionnaire for the Greek population.

    Science.gov (United States)

    Ypofanti, Maria; Zisi, Vasiliki; Zourbanos, Nikolaos; Mouchtouri, Barbara; Tzanne, Pothiti; Theodorakis, Yannis; Lyrakos, Georgios

    2015-09-30

    Goldberg's International Personality Item Pool (IPIP) big-five personality factor markers currently lack validating evidence. The structure of the 50-item IPIP was examined in two different adult samples (total N=811), in each case justifying a 5-factor solution, with only minor discrepancies. Age differences were comparable to previous findings using other inventories. One sample (N=193) also completed additionally another personality measure (the TIPI Short Form). Conscientiousness, extraversion and emotional stability/neuroticism scales of the IPIP were highly correlated with those of the TIPI (r=0.62 to 0.65, P=0.01). Agreeableness and Intellect/Openness scales correlated less strongly (r=0.54 and 0.58 respectively, P=0.01). The IPIP scales have good internal consistency (a=0.88) and relate strongly to major dimensions of personality assessed by the two questionnaires.

  1. The accurate measurement of the disintegration rate of 55Fe using an internal liquid scintillation counter

    International Nuclear Information System (INIS)

    Botha, S.M.

    1979-01-01

    As the well-known 4πX-γ-coincidence method cannot be used directly to find the disintegration rate of 55 Fe, another method was developed in which a tracer nuclide, possessing coincident gamma radiation, was used. It was now possible to determine the disintegration rate indirectly by the coincidence method using an internal liquid scintillation counter. 54 Mn and 51 Cr which lie in the immediate vicinity of iron in the series of nuclides, are suitable tracers. They are also electron capture nuclides, but decaying to an excited state, were counted by the 4πX-γ-coincidence method. A mixed source, containing 55 Fe and the tracer, was also counted by the coincidence method so that the 4π-counting rate of 55 Fe was obtained as function of the tracer's counting efficiency. It was also essential to find a relationship between the counting efficiencies of the liquid scintillation counter for 55 Fe and the tracer. This relationship is called the effeciency function. Efficiency functions were calculated for 55 Fe and 54 Mn as well as for 55 Fe and 51 Cr. Finally the radioactive concentration of a solution of 55 Fe had been carefully determined by using 54 Mn and 51 Cr tracers. The results for the two different tracers agreed within the statistical uncertainty of 0,4%. The systematic uncertainty on the final results was estimated as 0,17%

  2. Circulating Vitamin D and Colorectal Cancer Risk: An International Pooling Project of 17 Cohorts.

    Science.gov (United States)

    McCullough, Marjorie L; Zoltick, Emilie S; Weinstein, Stephanie J; Fedirko, Veronika; Wang, Molin; Cook, Nancy R; Eliassen, A Heather; Zeleniuch-Jacquotte, Anne; Agnoli, Claudia; Albanes, Demetrius; Barnett, Matthew J; Buring, Julie E; Campbell, Peter T; Clendenen, Tess V; Freedman, Neal D; Gapstur, Susan M; Giovannucci, Edward L; Goodman, Gary G; Haiman, Christopher A; Ho, Gloria Y F; Horst, Ronald L; Hou, Tao; Huang, Wen-Yi; Jenab, Mazda; Jones, Michael E; Joshu, Corinne E; Krogh, Vittorio; Lee, I-Min; Lee, Jung Eun; Männistö, Satu; Le Marchand, Loic; Mondul, Alison M; Neuhouser, Marian L; Platz, Elizabeth A; Purdue, Mark P; Riboli, Elio; Robsahm, Trude Eid; Rohan, Thomas E; Sasazuki, Shizuka; Schoemaker, Minouk J; Sieri, Sabina; Stampfer, Meir J; Swerdlow, Anthony J; Thomson, Cynthia A; Tretli, Steinar; Tsugane, Schoichiro; Ursin, Giske; Visvanathan, Kala; White, Kami K; Wu, Kana; Yaun, Shiaw-Shyuan; Zhang, Xuehong; Willett, Walter C; Gail, Mitchel H; Ziegler, Regina G; Smith-Warner, Stephanie A

    2018-06-14

    Experimental and epidemiological studies suggest a protective role for vitamin D in colorectal carcinogenesis, but evidence is inconclusive. Circulating 25-hydroxyvitamin D (25(OH)D) concentrations that minimize risk are unknown. Current Institute of Medicine (IOM) vitamin D guidance is based solely on bone health. We pooled participant-level data from 17 cohorts, comprising 5706 colorectal cancer case participants and 7107 control participants with a wide range of circulating 25(OH)D concentrations. For 30.1% of participants, 25(OH)D was newly measured. Previously measured 25(OH)D was calibrated to the same assay to permit estimating risk by absolute concentrations. Study-specific relative risks (RRs) for prediagnostic season-standardized 25(OH)D concentrations were calculated using conditional logistic regression and pooled using random effects models. Compared with the lower range of sufficiency for bone health (50-<62.5 nmol/L), deficient 25(OH)D (<30 nmol/L) was associated with 31% higher colorectal cancer risk (RR = 1.31, 95% confidence interval [CI] = 1.05 to 1.62); 25(OH)D above sufficiency (75-<87.5 and 87.5-<100 nmol/L) was associated with 19% (RR = 0.81, 95% CI = 0.67 to 0.99) and 27% (RR = 0.73, 95% CI = 0.59 to 0.91) lower risk, respectively. At 25(OH)D of 100 nmol/L or greater, risk did not continue to decline and was not statistically significantly reduced (RR = 0.91, 95% CI = 0.67 to 1.24, 3.5% of control participants). Associations were minimally affected when adjusting for body mass index, physical activity, or other risk factors. For each 25 nmol/L increment in circulating 25(OH)D, colorectal cancer risk was 19% lower in women (RR = 0.81, 95% CI = 0.75 to 0.87) and 7% lower in men (RR = 0.93, 95% CI = 0.86 to 1.00) (two-sided Pheterogeneity by sex = .008). Associations were inverse in all subgroups, including colorectal subsite, geographic region, and season of blood collection. Higher circulating 25(OH)D was related to a statistically

  3. Improving cylinder-type LiFePO4 battery performance via control of internal resistance

    Science.gov (United States)

    Purwanto, Agus; Jumari, Arif; Nizam, Muhammad; Widiyandari, Hendri; Sudaryanto; Deswita; Azmin Mohamad, Ahmad

    2018-04-01

    Strategies for controlling the internal resistance to improve battery performance were systematically investigated. Electrode densification of LiFePO4 cathodes significantly reduced the internal resistance of the prepared batteries. Densification by reduction to 31.25% of initial thickness resulted in optimal electrochemical performance of the prepared LiFePO4 batteries. The addition of KS 6 graphite material improved the conductivity of the cathodes, which was indicated by a lowering of the internal resistance. The internal resistance was decreased from 73 to 54 when the KS6/AB ratio was varied from 3 to 1. Another factor in controlling the internal resistance was the location of a welded aluminum tab in the cathode. The welding of an aluminum tab in a small gap in the cathode significantly reduced the internal resistance. Thus, three main factors can be performed during fabrication to reduce the internal resistance of a LiFePO4 battery: cathode densification, KS-6 graphite addition, and the arrangement of an aluminum tab welded to the cathode. By optimizing these factors, high-performance LFP batteries were produced.

  4. Examining changes in certification/licensure requirements and the international medical graduate examinee pool.

    Science.gov (United States)

    McKinley, Danette W; Hess, Brian J; Boulet, John R; Lipner, Rebecca S

    2014-03-01

    Changes in certification requirements and examinee characteristics are likely to influence the validity of the evidence associated with interpretations made based on test data. We examined whether changes in Educational Commission for Foreign Medical Graduates (ECFMG) certification requirements over time were associated with changes in internal medicine (IM) residency program director ratings and certification examination scores. Comparisons were made between physicians who were ECFMG-certified before and after the Clinical Skills Assessment (CSA) requirement. A multivariate analysis of covariance was conducted to examine the differences in program director ratings based on CSA cohort and whether the examinees emigrated for undergraduate medical education (national vs. international students). A univariate analysis of covariance was conducted to examine differences in scores from the American Board of Internal Medicine (ABIM) Internal Medicine Certification Examination. For both analyses, United States Medical Licensing Examination (USMLE) Step 1 and Step 2 scores were used as covariates. Results indicate that, of those certified by ECFMG between 1993 and 1997, 17 % (n = 1,775) left their country of citizenship for undergraduate medical education. In contrast, 38 % (n = 1,874) of those certified between 1999 and 2003 were international students. After adjustment by covariates, the main effect of cohort membership on the program director ratings was statistically significant (Wilks' λ = 0.99, F 5, 15391 = 19.9, P migration status was statistically significant and weak (Wilks' λ = 0.98, F 5,15391 = 45.3, P Internal Medicine Certification Examination scores based on whether or not CSA were required was statistically significant, although the magnitude of the association between these variables was very small. The findings suggest that the implementation of an additional evaluation of skills (e.g., history-taking, physical examination) as a

  5. The international performance of healthcare systems in population health: capabilities of pooled cross-sectional time series methods.

    Science.gov (United States)

    Reibling, Nadine

    2013-09-01

    This paper outlines the capabilities of pooled cross-sectional time series methodology for the international comparison of health system performance in population health. It shows how common model specifications can be improved so that they not only better address the specific nature of time series data on population health but are also more closely aligned with our theoretical expectations of the effect of healthcare systems. Three methodological innovations for this field of applied research are discussed: (1) how dynamic models help us understand the timing of effects, (2) how parameter heterogeneity can be used to compare performance across countries, and (3) how multiple imputation can be used to deal with incomplete data. We illustrate these methodological strategies with an analysis of infant mortality rates in 21 OECD countries between 1960 and 2008 using OECD Health Data. Copyright © 2013 The Author. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. The international dosimetry exchange for BNCT. A basis for pooling and collectively analyzing clinical results

    International Nuclear Information System (INIS)

    Riley, K.J.; Binns, P.J.; Harling, O.K.; Kiger, W.S. III; Seppaelae, T.; Savolainen, S.; Moss, R.; Marek, M.; Rezaei, A.

    2006-01-01

    An international collaboration was organized by the Massachusetts Institute of Technology (MIT) to undertake a dosimetry exchange for the eventual purpose of combining results from various clinical centers that employ different methods for measuring and prescribing absorbed dose in the mixed radiation fields used for neutron capture therapy. Treatment plans calculated at NCT centers in the Czech Republic, Finland, The Netherlands and Sweden were normalized to corresponding measurements performed by the MIT dosimetry group in each beam. More than half of the normalizations for individual absorbed dose components (photon, fast neutron, thermal neutron and boron) determined by comparing MIT measurements to the dose specified in treatment plans from the different centers were statistically significant and ranged from 8 to 400%. Each facility had at least one dose component that would require normalization for the specified doses to be accurately compared. These normalizations establish a technical basis to begin collectively analyzing treatment plans between the European and US centers. Simple but pertinent treatment parameters such as the maximum dose to brain can now be properly compared, once the clinical data is available. This could held to more precisely and quickly determine various dose-response relationships as for example those related to adverse events. Future efforts to determine dose normalization at other centers performing human studies as well as more sophisticated analyses using combined data from several centers should be guided by clearly defined clinical objectives with active participation from clinical BNCT experts. (author)

  7. Cash pooling

    OpenAIRE

    Lozovaya, Karina

    2009-01-01

    This work makes a mention of cash management. At next chapter describes two most known theoretical models of cash management -- Baumol Model and Miller-Orr Model. Principal part of work is about cash pooling, types of cash pooling, cash pooling at Czech Republic and influence of cash pooling over accounting and taxes.

  8. Neutron depolarization study of internal stresses in amorphous Fe40Ni40B20

    International Nuclear Information System (INIS)

    de Jong, M.; Sietsma, J.; Rekveldt, M.T.; van den Beukel, A.

    1997-01-01

    The magnetic domain structure of amorphous ferromagnets with nonzero magnetostriction is mainly determined by the internal stress state because of the magneto-elastic coupling. The stress and field dependence of the domain structure contains important information on the internal stresses in the material. The three-dimensional neutron depolarization technique has been used to study the stress- and field-dependence of the bulk domain structures in both as-quenched and annealed ribbons of the metallic glass Fe 40 Ni 40 B 20 . A three-layer domain structure model corresponding to compressive and tensile internal stresses is presented to explain the measured data. The influence of surface roughness on the interpretation of neutron depolarization measurements in amorphous ribbons is discussed. Finally, the internal stress relaxation due to the annealing is explained in terms of the viscous behaviour of the glass. copyright 1997 American Institute of Physics

  9. INAA analysis of rocks: A routine method using Fe as an internal flux monitor

    International Nuclear Information System (INIS)

    Kay, R.W.; Kay, S. Mahlburg

    1992-01-01

    Over the past decade at Cornell, trace elements in over 2500 rocks have been analyzed by INAA. The samples, mainly volcanic rocks, have known concentrations of major elements (e.g. Si, Ti, Al, Mg, Ca, K, Fe, Na) and the last two of these (Fe and Na) are also determined by activation, using rock standards (e.g. USGS standards BCRl, BHVO, etc.). Differences between Fe determined by INAA and that determined as a part of the major element analysis are mainly attributed to volatile (H 2 O, CO 2 ) loss (especially when major element analyses were done by electron microprobe on fused powders, whereas the INAA analyses were done on the powders), and to flux variability during irradiation. Instead of reporting two values for Fe we use Fe as an internal flux monitor, with Na and the trace elements being reported relative to the given Fe value. The ratio Na/Fe is used as a sensitive check on the identity of the sample and as a monitor of alkali loss affecting the major element analysis. Other than this modification (Kay et aL 1987, also reported in Chappell and Hergt, 1989) we use an INAA method similar to mat practiced by many labs. Powdered samples (about 0.5 g) are sealed in high-purity silica tubes and irradiated in the Cornell Triga reactor. Samples are counted for a minimum of 2 hours (up to 10 hours) 7 and 40 days after irradiation. Data are reduced using a program written at Cornell, with peak and background regions that have been checked for interferences. Corrections are routinely applied for Ce (Fe), Nd (Br), Tb (Th), Eu (Ba), Lu (U), and Yb (Th) (interference is from element in parentheses). A U fission yield correction is applied to La, Ce, Nd, and Ba. A correction for Ta introduced by grinding in WC containers can be made using known Ta/W ratios in the grinding containers. The correction amounted to 10-20% of the Ta gross peak. Recently, samples have been prepared in a ceramic grinding containers; for these, no Ta correction is needed. Trace elements determined

  10. Implementation of buffy-coat-derived pooled platelet concentrates for internal quality control of light transmission aggregometry: a proof of concept study.

    Science.gov (United States)

    Prüller, F; Rosskopf, K; Mangge, H; Mahla, E; von Lewinski, D; Weiss, E C; Riegler, A; Enko, D

    2017-12-01

    Essentials In platelet function testing, standardized internal controls (IQC) are not commercially provided. Platelet function testing was performed daily on aliquoted pooled platelet concentrates. Pooled platelet concentrates showed stability for control purposes from Monday to Friday. Pooled platelet concentrates provide the necessary steadiness to serve as IQC material. Background Standardized commercially available control material for internal quality control (IQC) of light transmission aggregometry (LTA) is still lacking. Moreover, the availability of normal blood donors to provide fresh platelets is difficult in small laboratories, where 'volunteers' may be in short supply. Objectives To evaluate the implementation of buffy-coat-derived pooled platelet concentrates (PCs) for IQC material for LTA. Methods We used buffy-coat-derived pooled PCs from the blood bank as IQC material for LTA. On each weekend one PC was prepared (> 200 mL) and aliquoted from the original storage bag on a daily basis in four baby bags (40-50 mL), which were delivered from Monday to Friday to our laboratory. The IQC measurements of at least 85 work-weeks (from Monday to Friday) were evaluated with this new IQC material. LTA was performed on a four-channel Chronolog 700 Aggregometer (Chronolog Corporation, Havertown, PA, USA) (agonists: collagen, adenosine diphosphate [ADP], arachidonic acid [AA] and thrombin receptor activator peptide-6 [TRAP-6]). Results The medians of platelet aggregation from IQC measurements with collagen, ADP and AA from Monday to Friday were 68.0-59.5, 3.0-2.0 and 51.0-50.0%, respectively, and the mean of platelet aggregation with TRAP-6 was 71.2-66.4%. Conclusions Buffy-coat-derived pooled PCs serve as a reliable and robust IQC material for LTA measurements and would be beneficial for the whole laboratory procedure and employees' safety. © 2017 International Society on Thrombosis and Haemostasis.

  11. Caesarean delivery and risk of childhood leukaemia: a pooled analysis from the Childhood Leukemia International Consortium (CLIC).

    Science.gov (United States)

    Marcotte, Erin L; Thomopoulos, Thomas P; Infante-Rivard, Claire; Clavel, Jacqueline; Petridou, Eleni Th; Schüz, Joachim; Ezzat, Sameera; Dockerty, John D; Metayer, Catherine; Magnani, Corrado; Scheurer, Michael E; Mueller, Beth A; Mora, Ana M; Wesseling, Catharina; Skalkidou, Alkistis; Rashed, Wafaa M; Francis, Stephen S; Ajrouche, Roula; Erdmann, Friederike; Orsi, Laurent; Spector, Logan G

    2016-04-01

    Results from case-control studies have shown an increased risk of acute lymphoblastic leukaemia (ALL) in young children born by caesarean delivery, and prelabour caesarean delivery in particular; however, an association of method of delivery with childhood leukaemia subtypes has yet to be established. We therefore did a pooled analysis of data to investigate the association between childhood leukaemia and caesarean delivery. We pooled data from 13 case-control studies from the Childhood Leukemia International Consortium done in nine countries (Canada, Costa Rica, Egypt, France, Germany, Greece, Italy, New Zealand, and the USA) for births from 1970-2013. We analysed caesarean delivery overall and by indications that probably resulted in prelabour caesarean delivery or emergency caesarean delivery. We used multivariable logistic regression models, adjusted for child's birthweight, sex, age, ethnic origin, parental education, maternal age, and study, to estimate odds ratios (ORs) and 95% CIs for the risk of ALL and acute myeloid leukaemia (AML) in children aged 0-14 years at diagnosis. The studies provided data for 8780 ALL cases, 1332 AML cases, and 23 459 controls, of which the birth delivery method was known for 8655 (99%) ALL cases, 1292 (97%) AML cases, and 23 351 (>99%) controls. Indications for caesarean delivery were available in four studies (there were caesarean deliveries for 1061 of 4313 ALL cases, 138 of 664 AML cases, and 1401 of 5884 controls). The OR for all indications of caesarean delivery and ALL was 1·06 (95% CI 0·99-1·13), and was significant for prelabour caesarean delivery and ALL (1·23 [1·04-1·47]; p=0·018). Emergency caesarean delivery was not associated with ALL (OR 1·02 [95% CI 0·81-1·30]). AML was not associated with caesarean delivery (all indications OR 0·99 [95% CI 0·84-1·17]; prelabour caesarean delivery 0·83 [0·54-1·26]; and emergency caesarean delivery 1·05 [0·63-1·77]). Our results suggest an increased risk of

  12. Exciting Pools

    Science.gov (United States)

    Wright, Bradford L.

    1975-01-01

    Advocates the creation of swimming pool oscillations as part of a general investigation of mechanical oscillations. Presents the equations, procedure for deriving the slosh modes, and methods of period estimation for exciting swimming pool oscillations. (GS)

  13. Selective Internal Oxidation and Severe Plastic Deformation of Multiphase Fe-Y Alloys

    Science.gov (United States)

    Kachur, Stephen J.

    Oxide dispersion strengthened (ODS) alloys are known for their desirable mechanical properties and unique microstructures. These alloys are characterized by an even dispersion of oxide phase throughout a metallic matrix, and exhibit high strength and enhanced creep properties at elevated temperatures. This makes them ideal candidate materials for use in many structural applications, such as coal-fired power plants or in next generation nuclear reactors. Currently most often produced by mechanical alloying, a powder metallurgy based process that utilizes high energy ball milling, these alloys are difficult and costly to produce. One proposed method for forming ODS alloys without high-energy ball milling is to internally oxidize a bulk alloy before subjecting it to severe plastic deformation to induce an even oxide distribution. This work examines such a processing scheme with a focus on the internal oxidation behavior. Internal oxidation has been shown to occur orders of magnitude faster than expected in multi-phase alloys where a highly reactive oxidizable solute has negligible solubility and diffusivity in other, more-noble, phases. Commonly referred to as in situ oxidation, this accelerated oxidation process has potential for use in a processing scheme for ODS alloys. While in situ oxidation has been observed in many different alloy systems, a comprehensive study of alloy composition and microstructure has not been performed to describe the unusual oxidation rates. This work used Fe-Y binary alloys as model system to study effects of composition and microstructure. These alloys have been shown to exhibit in situ oxidation, and additionally, Y is typically introduced during mechanical alloying to form Y-rich oxides in Fe-based ODS alloys. Alloys with Y content between 1.5 and 15 wt% were prepared using a laboratory scale arc-melting furnace. These alloys were two phase mixtures of Fe and Fe17Y2. First, samples were oxidized between 600 and 800 °C for 2 to 72

  14. The International NERSH Data Pool—A Methodological Description of a Data Pool of Religious and Spiritual Values of Health Professionals from Six Continents

    Directory of Open Access Journals (Sweden)

    Alex Kappel Kørup

    2017-02-01

    Full Text Available Collaboration within the recently established Network for Research on Spirituality and Health (NERSH has made it possible to pool data from 14 different surveys from six continents. All surveys are largely based on the questionnaire by Curlin “Religion and Spirituality in Medicine, Perspectives of Physicians” (RSMPP. This article is a methodological description of the process of building the International NERSH Data Pool. The larger contours of the data are described using frequency statistics. Five subscales in the data pool (including the already established DUREL scale were tested using Cronbach’s alpha and Principal Component Analysis (PCA in an Exploratory Factor Analysis (EFA. 5724 individuals were included, of which 57% were female and the mean age was 41.5 years with a 95% confidence interval (CI ranging from 41.2 to 41.8. Most respondents were physicians (n = 3883, nurses (n = 1189, and midwives (n = 286; but also psychologists (n = 50, therapists (n = 44, chaplains (n = 5, and students (n = 10 were included. The DUREL scale was assessed with Cronbach’s alpha (α = 0.92 and PCA confirmed its reliability and unidimensionality. The new scales covering the dimensions of “Religiosity of Health Professionals (HPs” (α = 0.89, “Willingness of Physicians to Interact with Patients Regarding R/S Issues” (α = 0.79, “Religious Objections to Controversial Issues in Medicine” (α = 0.78, and “R/S as a Calling” (α = 0.82, also proved unidimensional in the PCAs. We argue that the proposed scales are relevant and reliable measures of religious dimensions within the data pool. Finally, we outline future studies already planned based on the data pool, and invite interested researchers to join the NERSH collaboration.

  15. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  16. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  17. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia Proposal for the use of a pool of whole blood as internal quality control in hematology

    Directory of Open Access Journals (Sweden)

    Carina Daniele Schons

    2010-06-01

    Full Text Available INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenodiaminotetracético (EDTA, de mesmos grupo sanguíneo e fator Rh, livres de interferentes, como hemólise, lipemia e icterícia. De um total de 30 ml de sangue total, obtiveram-se três alíquotas de 10 ml cada, às quais foram adicionados, respectivamente, 0 ml (sem adição, 1 ml e 5 ml de glicerol (conservante. As amostras foram avaliadas em contador automático ADVIA® 60. Após determinação dos valores de média e DP, todas as amostras foram avaliadas por um período de 45 dias úteis para confecção do gráfico de Levey-Jennings e verificação da estabilidade da amostra. RESULTADO E CONCLUSÃO: Podemos verificar que o pool de sangue total, preparado de acordo com a metodologia proposta, não apresenta estabilidade necessária para sua utilização, como controle interno alternativo no setor de hematologia.INTRODUCTION: The reliability of laboratory results is ensured by the implementation of quality control, which has basic functions, such as analysis, research and prevention of laboratory errors through programs that encompass both internal and external control. OBJECTIVE: To propose a standard method to use pooled whole blood as internal quality control in the Hematology division. METHOD: The selected whole blood samples were collected with EDTA, belonged to the same blood group and Rh factor and did not present interfering factors, such as hemolysis, lipemia and icterus. From a total of 30 ml of whole blood it was obtained 3

  18. Internal friction of Fe-B alloys neutron irradiated at low temperature

    International Nuclear Information System (INIS)

    Kitajima, Kazunori; Futagami, Koji; Abe, Hironobu; Yoshida, Hiroyuki.

    1975-01-01

    Measurements were made on the internal friction of Fe-B alloys irradiated by neutron at 16 0 K to the dose of 3x10 16 nvt (>1 MeV) and 6x10 17 nvt (thermal). Boron was used to enhance the production of defects by the nuclear transformation B 10 (n,α)Li 7 . Relaxation peaks were found in specimens containing dispersed fine precipitates of NbB 2 in range of B 500--7200 wt ppm and Nb 2000--30000 wt ppm. The most prominent peak is the one with the peak temperature of 169 0 K at the frequency of 264 c/sec. Activation energy determined from the peak shift is 0.28+-0.01 eV, which is nearly equal to that of migration of self-interstitial reported on pure iron. However activation energy of the decay of peaks by annealing is about 0.7 eV. Interpretation was presented that the peak may be attributed to re-orientation of self-interstitials loosely bound to a boron atom. (auth.)

  19. Standardization of clinical enzyme analysis using frozen human serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures.

    Science.gov (United States)

    Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang

    Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.

  20. Some characteristics of the retention distribution and internal doses of 59Fe in rats

    International Nuclear Information System (INIS)

    Wang Deheng; Tian Wuxun; Zhang Hongyuan; Wen Quanfa; Hu Yuexin; Zhao Shanyin

    1993-01-01

    After gastric incubation, the whole body 59 Fe-retentions in rats were fit to two compartment exponential equations. The biological half life for 59 Fe in the slow compartment are 95 and 109 days for young and adult rats respectively, not statistically significantly different. The main 59 Fe-accumulative organs are liver and bone marrow. The biological eliminations of 59 Fe from most organs in young rats are faster than in adult rats. The young rats get more total accumulative dose in organs except liver and total body and have a faster dose accumulative speed than the adult rats. Equal quantities of 59 Fe P.O. may probably give young rats more intensive biological effects than adult rats

  1. Living on a farm, contact with farm animals and pets, and childhood acute lymphoblastic leukemia: pooled and meta-analyses from the Childhood Leukemia International Consortium.

    Science.gov (United States)

    Orsi, Laurent; Magnani, Corrado; Petridou, Eleni T; Dockerty, John D; Metayer, Catherine; Milne, Elizabeth; Bailey, Helen D; Dessypris, Nick; Kang, Alice Y; Wesseling, Catharina; Infante-Rivard, Claire; Wünsch-Filho, Victor; Mora, Ana M; Spector, Logan G; Clavel, Jacqueline

    2018-04-16

    The associations between childhood acute lymphoblastic leukemia (ALL) and several factors related to early stimulation of the immune system, that is, farm residence and regular contacts with farm animals (livestock, poultry) or pets in early childhood, were investigated using data from 13 case-control studies participating in the Childhood Leukemia International Consortium. The sample included 7847 ALL cases and 11,667 controls aged 1-14 years. In all studies, the data were obtained from case and control parents using standardized questionnaires. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were estimated by unconditional logistic regression adjusted for age, sex, study, maternal education, and maternal age. Contact with livestock in the first year of life was inversely associated with ALL (OR = 0.65, 95% CI: 0.50, 0.85). Inverse associations were also observed for contact with dogs (OR = 0.92, 95% CI: 0.86, 0.99) and cats (OR = 0.87, 95% CI: 0.80, 0.94) in the first year of life. There was no evidence of a significant association with farm residence in the first year of life. The findings of these large pooled and meta-analyses add additional evidence to the hypothesis that regular contact with animals in early childhood is inversely associated with childhood ALL occurrence which is consistent with Greaves' delayed infection hypothesis. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  2. Pool scrubbing

    International Nuclear Information System (INIS)

    Lopez-Jimenez, J.; Herranz, J.; Escudero, M.J.; Espigares, M.M.; Peyres, V.; Polo, J.; Kortz, Ch.; Koch, M.K.; Brockmeier, U.; Unger, H.; Dutton, L.M.C.; Smedley, Ch.; Trow, W.; Jones, A.V.; Bonanni, E.; Calvo, M.; Alonso, A.

    1996-12-01

    The Source Term Project in the Third Frame Work Programme of the European Union Was conducted under and important joined effort on pool scrubbing research. CIEMAT was the Task Manager of the project and several other organizations participated in it: JRC-Ispra, NNC Limited, RUB-NES and UPM. The project was divided into several tasks. A peer review of the models in the pool scrubbing codes SPARC90 and BUSCA-AUG92 was made, considering the different aspects in the hydrodynamic phenomenology, particle retention and fission product vapor abortions. Several dominant risk accident sequences were analyzed with MAAP, SPARC90 and BUSCA-AUG92 codes, and the predictions were compared. A churn-turbulent model was developed for the hydrodynamic behaviour of the pool. Finally, an experimental programme in the PECA facility of CIEMAT was conducted in order to study the decontamination factor under jet injection regime, and the experimental observations were compared with the SPARC and BUSCA codes. (Author)

  3. Observation of changing of the internal conversion coefficient under Moessbauer effect at magnetic transition in Rh-Fe system

    International Nuclear Information System (INIS)

    Ruskov, T.

    1998-01-01

    The magnetic disorder-order transition in the Rh-Fe alloy is studied by conversion electron Moessbauer spectroscopy. The drastic increase of the area under the Moessbauer spectrum at the transition from the paramagnetic to the magnetic state could be explained by diminishing the internal conversion coefficient. Thus our experimental results directly confirm the theory of the collective effect in the system of radiating developed by Yukalov

  4. Associated Links Among Smoking, Chronic Obstructive Pulmonary Disease, and Small Cell Lung Cancer: A Pooled Analysis in the International Lung Cancer Consortium

    Directory of Open Access Journals (Sweden)

    Ruyi Huang

    2015-11-01

    Interpretation: This is the largest pooling study that provides improved understanding of smoking on SCLC, and further demonstrates a causal pathway through COPD that warrants further experimental study.

  5. Hawaii ESI: POOLS (Anchialine Pool Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains sensitive biological resource data for anchialine pools in Hawaii. Anchialine pools are small, relatively shallow coastal ponds that occur...

  6. Exposure to secondhand tobacco smoke and lung cancer by histological type: a pooled analysis of the International Lung Cancer Consortium (ILCCO)

    Science.gov (United States)

    Kim, Claire H; Lee, Yuan-Chin Amy; Hung, Rayjean J; McNallan, Sheila R; Cote, Michele L; Lim, Wei-Yen; Chang, Shen-Chih; Kim, Jin Hee; Ugolini, Donatella; Chen, Ying; Liloglou, Triantafillos; Andrew, Angeline S; Onega, Tracy; Duell, Eric J; Field, John K; Lazarus, Philip; Le Marchand, Loic; Neri, Monica; Vineis, Paolo; Kiyohara, Chikako; Hong, Yun-Chul; Morgenstern, Hal; Matsuo, Keitaro; Tajima, Kazuo; Christiani, David C; McLaughlin, John R; Bencko, Vladimir; Holcatova, Ivana; Boffetta, Paolo; Brennan, Paul; Fabianova, Eleonora; Foretova, Lenka; Janout, Vladimir; Lissowska, Jolanta; Mates, Dana; Rudnai, Peter; Szeszenia-Dabrowska, Neonila; Mukeria, Anush; Zaridze, David; Seow, Adeline; Schwartz, Ann G; Yang, Ping; Zhang, Zuo-Feng

    2014-01-01

    While the association between exposure to secondhand smoke and lung cancer risk is well established, few studies with sufficient power have examined the association by histological type. In this study, we evaluated the secondhand smoke-lung cancer relationship by histological type based on pooled data from 18 case-control studies in the International Lung Cancer Consortium (ILCCO), including 2,504 cases and 7,276 controls who were never smokers and 10,184 cases and 7,176 controls who were ever smokers. We used multivariable logistic regression, adjusting for age, sex, race/ethnicity, smoking status, pack-years of smoking, and study. Among never smokers, the odds ratios (OR) comparing those ever exposed to secondhand smoke with those never exposed were 1.31 (95% CI: 1.17–1.45) for all histological types combined, 1.26 (95% CI: 1.10–1.44) for adenocarcinoma, 1.41 (95% CI: 0.99–1.99) for squamous cell carcinoma, 1.48 (95% CI: 0.89–2.45) for large cell lung cancer, and 3.09 (95% CI: 1.62–5.89) for small cell lung cancer. The estimated association with secondhand smoke exposure was greater for small cell lung cancer than for non-small cell lung cancers (OR=2.11, 95% CI: 1.11–4.04). This analysis is the largest to date investigating the relation between exposure to secondhand smoke and lung cancer. Our study provides more precise estimates of the impact of secondhand smoke on the major histological types of lung cancer, indicates the association with secondhand smoke is stronger for small cell lung cancer than for the other histological types, and suggests the importance of intervention against exposure to secondhand smoke in lung cancer prevention. PMID:24615328

  7. Exposure to secondhand tobacco smoke and lung cancer by histological type: a pooled analysis of the International Lung Cancer Consortium (ILCCO).

    Science.gov (United States)

    Kim, Claire H; Lee, Yuan-Chin Amy; Hung, Rayjean J; McNallan, Sheila R; Cote, Michele L; Lim, Wei-Yen; Chang, Shen-Chih; Kim, Jin Hee; Ugolini, Donatella; Chen, Ying; Liloglou, Triantafillos; Andrew, Angeline S; Onega, Tracy; Duell, Eric J; Field, John K; Lazarus, Philip; Le Marchand, Loic; Neri, Monica; Vineis, Paolo; Kiyohara, Chikako; Hong, Yun-Chul; Morgenstern, Hal; Matsuo, Keitaro; Tajima, Kazuo; Christiani, David C; McLaughlin, John R; Bencko, Vladimir; Holcatova, Ivana; Boffetta, Paolo; Brennan, Paul; Fabianova, Eleonora; Foretova, Lenka; Janout, Vladimir; Lissowska, Jolanta; Mates, Dana; Rudnai, Peter; Szeszenia-Dabrowska, Neonila; Mukeria, Anush; Zaridze, David; Seow, Adeline; Schwartz, Ann G; Yang, Ping; Zhang, Zuo-Feng

    2014-10-15

    While the association between exposure to secondhand smoke and lung cancer risk is well established, few studies with sufficient power have examined the association by histological type. In this study, we evaluated the secondhand smoke-lung cancer relationship by histological type based on pooled data from 18 case-control studies in the International Lung Cancer Consortium (ILCCO), including 2,504 cases and 7,276 control who were never smokers and 10,184 cases and 7,176 controls who were ever smokers. We used multivariable logistic regression, adjusting for age, sex, race/ethnicity, smoking status, pack-years of smoking, and study. Among never smokers, the odds ratios (OR) comparing those ever exposed to secondhand smoke with those never exposed were 1.31 (95% CI: 1.17-1.45) for all histological types combined, 1.26 (95% CI: 1.10-1.44) for adenocarcinoma, 1.41 (95% CI: 0.99-1.99) for squamous cell carcinoma, 1.48 (95% CI: 0.89-2.45) for large cell lung cancer, and 3.09 (95% CI: 1.62-5.89) for small cell lung cancer. The estimated association with secondhand smoke exposure was greater for small cell lung cancer than for nonsmall cell lung cancers (OR=2.11, 95% CI: 1.11-4.04). This analysis is the largest to date investigating the relation between exposure to secondhand smoke and lung cancer. Our study provides more precise estimates of the impact of secondhand smoke on the major histological types of lung cancer, indicates the association with secondhand smoke is stronger for small cell lung cancer than for the other histological types, and suggests the importance of intervention against exposure to secondhand smoke in lung cancer prevention. © 2014 UICC.

  8. Evaluation of fire models for nuclear power plant applications. Benchmark exercise no. 4: Fuel pool fire inside a compartment - International panel report

    International Nuclear Information System (INIS)

    Klein-Hessling, W.; Roewekamp, M.; Riese, O.

    2006-11-01

    Fire simulations as well as their analytical validation procedures have gained more and more significance, particularly in the context of the fire safety analysis for operating nuclear power plants. Meanwhile, fire simulation models have been adapted as analytical tools for a risk oriented fire safety assessment. Calculated predictions can be used, on the one hand, for the improvements and upgrades of fire protection in nuclear power plants by the licensees and, on the other hand, as a tool for reproducible and clearly understandable estimations in assessing the available and/or foreseen fire protection measures by the authorities and their experts. For consideration of such aspects in the context of implementing new nuclear fire protection standards or of updating existing ones, an 'International Collaborative Project to Evaluate Fire Models for Nuclear Power Plant Applications' also known as the 'International Collaborative Fire Model Project' (ICFMP) was started in 1999. It has made use of the experience and knowledge of a variety of worldwide expert institutions in this field to assess and improve, if necessary, the state-of-the-art with respect to modeling fires in nuclear power plants and other nuclear installations. This document contains the results of the ICFMP Benchmark Exercise No. 4, where two fuel pool fire experiments in an enclosure with two different natural vent sizes have been considered. Analyzing the results of different fire simulation codes and code types provides some indications with respect to the uncertainty of the results. This information is especially important in setting uncertainty parameters in probabilistic risk studies and to provide general insights concerning the applicability and limitations in the application of different types of fire simulation codes for this type of fire scenario and boundary conditions. During the benchmark procedure the participants performed different types of calculations. These included totally blind

  9. Development of Novel Fe-Based Coating Systems for Internal Combustion Engines

    Science.gov (United States)

    Bobzin, K.; Öte, M.; Königstein, T.; Dröder, K.; Hoffmeister, H.-W.; Mahlfeld, G.; Schläfer, T.

    2018-04-01

    Nowadays, combustion engines are the most common way to power vehicles. Thereby, losses occur due to cooling, exhaust gas and friction. With regard to frictional losses, highest potentials for optimization can be found in the tribological system of the inner surface of combustion chamber and piston ring. Besides friction, corrosive stress increases, e.g., due to utilization of exhaust gas recovery. In order to save energy, reduce emissions and enhance the life span of combustion engines, the demand for innovative coating material systems, especially for the inner surface of combustion chamber, increases. This study focuses on the development of innovative iron-based coating materials for the combustion chamber. As a first step, the plasma transferred wire arc and rotating single wire arc (RSW) technologies were compared using 0.8% C-steel as a reference. Subsequently, RSW was used for coating deposition using an innovative iron-based feedstock material. In order to improve wear and corrosion resistance, boron and chromium were added to the feedstock material. After deposition, different honing topographies were manufactured and compared under tribological load. Furthermore, electrochemical corrosion tests were conducted using an electrolyte simulating the exhaust gas concentrate. Especially with regard to corrosion, the novel coating system FeCrBMn showed promising results.

  10. Internal stress evolution in Fe laths deformed at low temperature analysed by dislocation dynamics simulations

    International Nuclear Information System (INIS)

    Chaussidon, Julien; Fivel, Marc; Robertson, Christian; Marini, Bernard

    2010-01-01

    Stress evolution in Fe laths undergoing plastic deformation is investigated using three-dimensional dislocation dynamics simulations adapted to body centred cubic crystals, in the ductile to brittle transition temperature range. The selected boundary conditions, applied stress tensor and initial dislocation structures account for the realistic microstructure observed in bainitic steels. The effective stress field projected in the three different {1 0 0}cleavage planes is calculated for two different temperatures (50 and 200 K) and presented quantitatively, in the form of stress/frequency diagrams. It is shown that plastic activity tends to relax the stress acting in certain cleavage planes (the (0 1 0) and (0 0 1) planes) while, at the same time, amplifying the stress acting in other cleavage planes (the (1 0 0) planes). The selective stress amplification in the latter planes depends on the applied load direction, in combination with the limited set of available slip systems and the lath geometry. In the examined configuration, this selection effect is more pronounced with decreasing temperature, emphasizing the role of thermally activated plasticity on deformation-induced stress concentrations

  11. Report on International Collaboration Involving the FE Heater and HG-A Tests at Mont Terri

    Energy Technology Data Exchange (ETDEWEB)

    Houseworth, Jim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Asahina, Daisuke [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chen, Fei [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vilarrasa, Victor [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liu, Hui-Hai [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-11-01

    Nuclear waste programs outside of the US have focused on different host rock types for geological disposal of high-level radioactive waste. Several countries, including France, Switzerland, Belgium, and Japan are exploring the possibility of waste disposal in shale and other clay-rich rock that fall within the general classification of argillaceous rock. This rock type is also of interest for the US program because the US has extensive sedimentary basins containing large deposits of argillaceous rock. LBNL, as part of the DOE-NE Used Fuel Disposition Campaign, is collaborating on some of the underground research laboratory (URL) activities at the Mont Terri URL near Saint-Ursanne, Switzerland. The Mont Terri project, which began in 1995, has developed a URL at a depth of about 300 m in a stiff clay formation called the Opalinus Clay. Our current collaboration efforts include two test modeling activities for the FE heater test and the HG-A leak-off test. This report documents results concerning our current modeling of these field tests. The overall objectives of these activities include an improved understanding of and advanced relevant modeling capabilities for EDZ evolution in clay repositories and the associated coupled processes, and to develop a technical basis for the maximum allowable temperature for a clay repository.

  12. Development of Novel Fe-Based Coating Systems for Internal Combustion Engines

    Science.gov (United States)

    Bobzin, K.; Öte, M.; Königstein, T.; Dröder, K.; Hoffmeister, H.-W.; Mahlfeld, G.; Schläfer, T.

    2018-02-01

    Nowadays, combustion engines are the most common way to power vehicles. Thereby, losses occur due to cooling, exhaust gas and friction. With regard to frictional losses, highest potentials for optimization can be found in the tribological system of the inner surface of combustion chamber and piston ring. Besides friction, corrosive stress increases, e.g., due to utilization of exhaust gas recovery. In order to save energy, reduce emissions and enhance the life span of combustion engines, the demand for innovative coating material systems, especially for the inner surface of combustion chamber, increases. This study focuses on the development of innovative iron-based coating materials for the combustion chamber. As a first step, the plasma transferred wire arc and rotating single wire arc (RSW) technologies were compared using 0.8% C-steel as a reference. Subsequently, RSW was used for coating deposition using an innovative iron-based feedstock material. In order to improve wear and corrosion resistance, boron and chromium were added to the feedstock material. After deposition, different honing topographies were manufactured and compared under tribological load. Furthermore, electrochemical corrosion tests were conducted using an electrolyte simulating the exhaust gas concentrate. Especially with regard to corrosion, the novel coating system FeCrBMn showed promising results.

  13. Introduction to the first International Workshop on the Application of Microporous and Mesoporous Materials as Catalytic Hosts for Fe, Cu an Co

    NARCIS (Netherlands)

    Donk, van S.; Weckhuysen, B.M.; Kapteijn, F.; Kooyman, P.J.; Hensen, E.J.M.

    2005-01-01

    This Special Issue of Catalysis Today includes a selection of research presented at the first International Workshop on the ‘Application of Microporous and Mesoporous Materials as Catalytic Hosts for Fe, Cu and Co’, held in Scheveningen, The Netherlands, 1–4 March 2005. This 3-day event welcomed

  14. Swimming pool cleaner poisoning

    Science.gov (United States)

    Swimming pool cleaner poisoning occurs when someone swallows this type of cleaner, touches it, or breathes in ... The harmful substances in swimming pool cleaner are: Bromine ... copper Chlorine Soda ash Sodium bicarbonate Various mild acids

  15. Swimming pool granuloma

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001357.htm Swimming pool granuloma To use the sharing features on this page, please enable JavaScript. A swimming pool granuloma is a long-term (chronic) skin ...

  16. A multiscale MD-FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure.

    Science.gov (United States)

    Kojic, M; Milosevic, M; Kojic, N; Kim, K; Ferrari, M; Ziemys, A

    2014-02-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts.

  17. A multiscale MD–FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure

    Science.gov (United States)

    Kojic, M.; Milosevic, M.; Kojic, N.; Kim, K.; Ferrari, M.; Ziemys, A.

    2014-01-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts. PMID:24578582

  18. Young Adult and Usual Adult Body Mass Index and Multiple Myeloma Risk: A Pooled Analysis in the International Multiple Myeloma Consortium (IMMC).

    Science.gov (United States)

    Birmann, Brenda M; Andreotti, Gabriella; De Roos, Anneclaire J; Camp, Nicola J; Chiu, Brian C H; Spinelli, John J; Becker, Nikolaus; Benhaim-Luzon, Véronique; Bhatti, Parveen; Boffetta, Paolo; Brennan, Paul; Brown, Elizabeth E; Cocco, Pierluigi; Costas, Laura; Cozen, Wendy; de Sanjosé, Silvia; Foretová, Lenka; Giles, Graham G; Maynadié, Marc; Moysich, Kirsten; Nieters, Alexandra; Staines, Anthony; Tricot, Guido; Weisenburger, Dennis; Zhang, Yawei; Baris, Dalsu; Purdue, Mark P

    2017-06-01

    Background: Multiple myeloma risk increases with higher adult body mass index (BMI). Emerging evidence also supports an association of young adult BMI with multiple myeloma. We undertook a pooled analysis of eight case-control studies to further evaluate anthropometric multiple myeloma risk factors, including young adult BMI. Methods: We conducted multivariable logistic regression analysis of usual adult anthropometric measures of 2,318 multiple myeloma cases and 9,609 controls, and of young adult BMI (age 25 or 30 years) for 1,164 cases and 3,629 controls. Results: In the pooled sample, multiple myeloma risk was positively associated with usual adult BMI; risk increased 9% per 5-kg/m 2 increase in BMI [OR, 1.09; 95% confidence interval (CI), 1.04-1.14; P = 0.007]. We observed significant heterogeneity by study design ( P = 0.04), noting the BMI-multiple myeloma association only for population-based studies ( P trend = 0.0003). Young adult BMI was also positively associated with multiple myeloma (per 5-kg/m 2 ; OR, 1.2; 95% CI, 1.1-1.3; P = 0.0002). Furthermore, we observed strong evidence of interaction between younger and usual adult BMI ( P interaction adult BMI may increase multiple myeloma risk and suggest that healthy BMI maintenance throughout life may confer an added benefit of multiple myeloma prevention. Cancer Epidemiol Biomarkers Prev; 26(6); 876-85. ©2017 AACR . ©2017 American Association for Cancer Research.

  19. Solar swimming pool

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This report examines the feasibility of using solar collectors to heat the water in a previously unheated outdoor swimming pool. The solar system is used in conjunction with a pool blanket, to conserve heat when the pool is not in use. Energy losses through evaporation can be reduced by as much as 70% by a pool blanket. A total of 130 m{sup 2} of highly durable black synthetic collectors were installed on a support structure at a 30{degree} angle from the horizontal, oriented to the south. Circulation of pool water though the collectors, which is controlled by a differential thermostat, was done with the existing pool pump. Before installation the pool temperature averaged 16{degree}C; after installation it ranged from 20{degree} to 26{degree}C. It was hard to distinguish how much pool heating was due to the solar system and how much heat was retained by the pool blanket. However, the pool season was extended by five weeks and attendance tripled. 2 figs.

  20. 17 CFR 4.22 - Reporting to pool participants.

    Science.gov (United States)

    2010-04-01

    ..., the financial statements are not required to include consolidated information for all series. (7) For... event that the International Financial Reporting Standards require consolidated financial statements for... reporting pool's consolidated financial statements. (ii) The commodity pool operator of a pool that meets...

  1. Swimming-pool piles

    International Nuclear Information System (INIS)

    Trioulaire, M.

    1959-01-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10 13 . This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [fr

  2. Generalizing Pooling Functions in CNNs: Mixed, Gated, and Tree.

    Science.gov (United States)

    Lee, Chen-Yu; Gallagher, Patrick; Tu, Zhuowen

    2018-04-01

    In this paper, we seek to improve deep neural networks by generalizing the pooling operations that play a central role in the current architectures. We pursue a careful exploration of approaches to allow pooling to learn and to adapt to complex and variable patterns. The two primary directions lie in: (1) learning a pooling function via (two strategies of) combining of max and average pooling, and (2) learning a pooling function in the form of a tree-structured fusion of pooling filters that are themselves learned. In our experiments every generalized pooling operation we explore improves performance when used in place of average or max pooling. We experimentally demonstrate that the proposed pooling operations provide a boost in invariance properties relative to conventional pooling and set the state of the art on several widely adopted benchmark datasets. These benefits come with only a light increase in computational overhead during training (ranging from additional 5 to 15 percent in time complexity) and a very modest increase in the number of model parameters (e.g., additional 1, 9, and 27 parameters for mixed, gated, and 2-level tree pooling operators, respectively). To gain more insights about our proposed pooling methods, we also visualize the learned pooling masks and the embeddings of the internal feature responses for different pooling operations. Our proposed pooling operations are easy to implement and can be applied within various deep neural network architectures.

  3. Chinese nuclear insurance and Chinese nuclear insurance pool

    International Nuclear Information System (INIS)

    Gong Zhiqi

    2000-01-01

    Chinese Nuclear Insurance Started with Daya Bay Nuclear Power Station, PICC issued the insurance policy. Nuclear insurance cooperation between Chinese and international pool's organizations was set up in 1989. In 1996, the Chinese Nuclear Insurance Pool was prepared. The Chinese Nuclear Insurance Pool was approved by The Chinese Insurance Regulatory Committee in May of 1999. The principal aim is to centralize maximum the insurance capacity for nuclear insurance from local individual insurers and to strengthen the reinsurance relations with international insurance pools so as to provide the high quality insurance service for Chinese nuclear industry. The Member Company of Chinese Nuclear Pool and its roles are introduced in this article

  4. Effect of the internal pressure and the anti-site disorder on the structure and magnetic properties of ALaFeTiO6 (A=Ca, Sr, Ba) double perovskite oxides

    International Nuclear Information System (INIS)

    Elbadawi, A.A.; Yassin, O.A.; Gismelseed, Abbasher A.

    2013-01-01

    Successful preparation of double perovskite oxides of chemical formula ALaFeTiO 6 (A=Ba, Sr and Ca) has been achieved by following the precursor method. The samples were studied by means of X-ray diffraction and Mössbauer spectroscopy. The Rietveld analysis of the X-ray diffraction data showed that all the samples have anti-site disorder. The presence of anti-site disorder has altered the electronic environment around the Fe ion sites which creates electric field gradient between two different sites. Observation of quadruple splitting in the ideal cubic perovskite BaLaFeTiO 6 (its tolerance factor equals 1) is the evidence of this anti-site generated electric field gradient. The valence state of the Fe atom determined from the measurements of the Mössbauer effect of 57 Fe at room temperature and 80 K showed that the iron ion has the Fe 3+ high spin state as extracted from the values of the isomer shift for all the samples. It is evidenced that the anti-site disorder has no appreciable effect on the spin state of the Fe ion, but alters the charge densities at the Fe sites and influences the hyperfine parameters of the present samples. Weak ferromagnetism is observed in CaLaFeTiO 6 and SrLaFeTiO 6 and is related to both the internal pressure and the anti-site effect which facilitate the occurrence of the Fe 3+ ↑−O−Fe 3+ ↓ antiferromagnetic interaction with canted spin. - Highlights: ► Anti-site disorder was revealed in (Ca,Sr,Ba)LaFeTiO 6 double perovskites. ► Mössbauer spectroscopy revealed a dependence of the quadruple splitting and the cation size mismatch. ► Weak ferromagnetism is evidenced due to internal pressure and anti-site disorder.

  5. Spent fuel storage pool

    International Nuclear Information System (INIS)

    Murakami, Naoshi.

    1996-01-01

    Fences are disposed to a fuel exchange floor surrounding the upper surface of a fuel pool for preventing overflow of pool water. The fences comprise a plurality of flat boards arranged in parallel with each other in the longitudinal direction while being vertically inclined, and slits are disposed between the boards for looking down the pool. Further, the fences comprise wide boards and are constituted so as to be laid horizontally on the fuel exchange floor in a normal state and uprisen by means of the signals from an earthquake sensing device. Even if pool water is overflow from the fuel pool by the vibrations occurred upon earthquake and flown out to the floor of the fuel exchange floor, the overflow from the fuel exchange floor is prevented by the fences. An operator who monitors the fuel pool can observe the inside of the fuel pool through the slits formed to the fences during normal operation. The fences act as resistance against overflowing water upon occurrence of an earthquake thereby capable of reducing the overflowing amount of water due to the vibrations of pool water. The effect of preventing overflowing water can be enhanced. (N.H.)

  6. Collaborative Car Pooling System

    OpenAIRE

    João Ferreira; Paulo Trigo; Porfírio Filipe

    2009-01-01

    This paper describes the architecture for a collaborative Car Pooling System based on a credits mechanism to motivate the cooperation among users. Users can spend the accumulated credits on parking facilities. For this, we propose a business model to support the collaboration between a car pooling system and parking facilities. The Portuguese Lisbon-s Metropolitan area is used as application scenario.

  7. The role of sleep difficulties in the vasomotor menopausal symptoms and depressed mood relationships: an international pooled analysis of eight studies in the InterLACE consortium.

    Science.gov (United States)

    Chung, Hsin-Fang; Pandeya, Nirmala; Dobson, Annette J; Kuh, Diana; Brunner, Eric J; Crawford, Sybil L; Avis, Nancy E; Gold, Ellen B; Mitchell, Ellen S; Woods, Nancy F; Bromberger, Joyce T; Thurston, Rebecca C; Joffe, Hadine; Yoshizawa, Toyoko; Anderson, Debra; Mishra, Gita D

    2018-02-12

    Many women experience both vasomotor menopausal symptoms (VMS) and depressed mood at midlife, but little is known regarding the prospective bi-directional relationships between VMS and depressed mood and the role of sleep difficulties in both directions. A pooled analysis was conducted using data from 21 312 women (median: 50 years, interquartile range 49-51) in eight studies from the InterLACE consortium. The degree of VMS, sleep difficulties, and depressed mood was self-reported and categorised as never, rarely, sometimes, and often (if reporting frequency) or never, mild, moderate, and severe (if reporting severity). Multivariable logistic regression models were used to examine the bi-directional associations adjusted for within-study correlation. At baseline, the prevalence of VMS (40%, range 13-62%) and depressed mood (26%, 8-41%) varied substantially across studies, and a strong dose-dependent association between VMS and likelihood of depressed mood was found. Over 3 years of follow-up, women with often/severe VMS at baseline were more likely to have subsequent depressed mood compared with those without VMS (odds ratios (OR) 1.56, 1.27-1.92). Women with often/severe depressed mood at baseline were also more likely to have subsequent VMS than those without depressed mood (OR 1.89, 1.47-2.44). With further adjustment for the degree of sleep difficulties at baseline, the OR of having a subsequent depressed mood associated with often/severe VMS was attenuated and no longer significant (OR 1.13, 0.90-1.40). Conversely, often/severe depressed mood remained significantly associated with subsequent VMS (OR 1.80, 1.38-2.34). Difficulty in sleeping largely explained the relationship between VMS and subsequent depressed mood, but it had little impact on the relationship between depressed mood and subsequent VMS.

  8. 13 CFR 120.611 - Pools backing Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pools backing Pool Certificates. 120.611 Section 120.611 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Certificates § 120.611 Pools backing Pool Certificates. (a) Pool characteristics. As set...

  9. PDA: Pooled DNA analyzer

    Directory of Open Access Journals (Sweden)

    Lin Chin-Yu

    2006-04-01

    Full Text Available Abstract Background Association mapping using abundant single nucleotide polymorphisms is a powerful tool for identifying disease susceptibility genes for complex traits and exploring possible genetic diversity. Genotyping large numbers of SNPs individually is performed routinely but is cost prohibitive for large-scale genetic studies. DNA pooling is a reliable and cost-saving alternative genotyping method. However, no software has been developed for complete pooled-DNA analyses, including data standardization, allele frequency estimation, and single/multipoint DNA pooling association tests. This motivated the development of the software, 'PDA' (Pooled DNA Analyzer, to analyze pooled DNA data. Results We develop the software, PDA, for the analysis of pooled-DNA data. PDA is originally implemented with the MATLAB® language, but it can also be executed on a Windows system without installing the MATLAB®. PDA provides estimates of the coefficient of preferential amplification and allele frequency. PDA considers an extended single-point association test, which can compare allele frequencies between two DNA pools constructed under different experimental conditions. Moreover, PDA also provides novel chromosome-wide multipoint association tests based on p-value combinations and a sliding-window concept. This new multipoint testing procedure overcomes a computational bottleneck of conventional haplotype-oriented multipoint methods in DNA pooling analyses and can handle data sets having a large pool size and/or large numbers of polymorphic markers. All of the PDA functions are illustrated in the four bona fide examples. Conclusion PDA is simple to operate and does not require that users have a strong statistical background. The software is available at http://www.ibms.sinica.edu.tw/%7Ecsjfann/first%20flow/pda.htm.

  10. Internal versus external fixation of the anterior component in unstable fractures of the pelvic ring: pooled results from a systematic review.

    Science.gov (United States)

    Wardle, B; Eslick, G D; Sunner, P

    2016-10-01

    Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are

  11. Mapping the transition from catalyst-pool to bamboo-like growth-mechanism in vertically-aligned free-standing films of carbon nanotubes filled with Fe3C: The key role of water

    Directory of Open Access Journals (Sweden)

    Filippo S. Boi

    2016-08-01

    Full Text Available The control of carbon nanotube growth has challenged researchers for more than a decade due to the complex parameters-control necessary in the commonly used CVD approaches. Here we show that a direct transition from the catalyst-pool growth mechanism characterized by graphene-caps in the direction of growth to a bamboo-shaped mechanism characterized by the repetition of periodic elongated graphitic compartments is present when controlled quantities of water are added to ferrocene/dichlorobenzene. Our results suggest that water-addition allows enhancing the level of stress accumulated under the graphitic nanotubes-cap.

  12. Mapping the transition from catalyst-pool to bamboo-like growth-mechanism in vertically-aligned free-standing films of carbon nanotubes filled with Fe3C: The key role of water

    Science.gov (United States)

    Boi, Filippo S.; Wang, Shanling; He, Yi

    2016-08-01

    The control of carbon nanotube growth has challenged researchers for more than a decade due to the complex parameters-control necessary in the commonly used CVD approaches. Here we show that a direct transition from the catalyst-pool growth mechanism characterized by graphene-caps in the direction of growth to a bamboo-shaped mechanism characterized by the repetition of periodic elongated graphitic compartments is present when controlled quantities of water are added to ferrocene/dichlorobenzene. Our results suggest that water-addition allows enhancing the level of stress accumulated under the graphitic nanotubes-cap.

  13. Swimming Pool Safety

    Science.gov (United States)

    ... Spread the Word Shop AAP Find a Pediatrician Safety & Prevention Immunizations All Around At Home At Play ... Español Text Size Email Print Share Swimming Pool Safety Page Content ​What is the best way to ...

  14. Vitamin D Pooling Project

    Science.gov (United States)

    The Vitamin D Pooling Project of Rarer Cancers brought together investigators from 10 cohorts to conduct a large prospective epidemiologic study of the association between vitamin D status and seven rarer cancers.

  15. Swimming pool special; Zwembadspecial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-05-15

    This issue includes a few articles and messages on the use of heat pump systems in swimming pools. [Dutch] Dit nummer bevat onder meer een paar artikelen over het gebruik van warmtepompsystemen in zwembaden.

  16. Nuclear Insurance Pools: Worldwide Practice and Development

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    1998-01-01

    The development of nuclear installations to produce electricity led to the establishment of Nuclear Insurance Pools and the introduction of international Conventions on Third Party Liability. Nuclear Pools offer both Third Party Liability insurance, reflecting the Conventions' principles, and other insurance products. They are market-wide, providing a facility for participation by insurers who could not otherwise write the insurance for the particularly sensitive nuclear risk. All acceptances are for the net retention of each Member without recourse to individual reinsurance protection. Common account reinsurance is arranged with other Nuclear Pools all over the world. Thus, a transparency is created, which ensures the highest degree of reinsurance security and imposes a known finite limit to each participating insurer's commitment. Therefore, Pool-members are prepared to make a greater commitment to nuclear risks than would be case where they felt uncertain as regards their total exposure following a significant loss. (author)

  17. Pool water cleaning facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro [Hitachi Ltd., Tokyo (Japan); Asano, Takashi

    1998-05-29

    Only one system comprising a suppression poor water cleaning system (SPCU) and a filtration desalting tower (F/D) is connected for a plurality of nuclear power plants. Pipelines/valves for connecting the one system of the SPCU pump, the F/D and the plurality of nuclear power plants are disposed, and the system is used in common with the plurality of nuclear power plants. Pipelines/valves for connecting a pipeline for passing SP water to the commonly used SPCU pump and a skimmer surge tank are disposed, and fuel pool water is cooled and cleaned by the commonly used SPCU pump and the commonly used F/D. The number of SPCU pumps and the F/D facilities can be reduced, and a fuel pool water cooling operation mode and a fuel pool water cleaning operation mode which were conducted by an FPC pump so far are conducted by the SPCU pump. (N.H.)

  18. Liquid sodium pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Casselman, C [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  19. Income pooling within families

    DEFF Research Database (Denmark)

    Bonke, Jens; Uldall-Poulsen, Hans

    This paper analyses the phenomenon of income-pooling by applying the Danish household expenditure survey, merged with authoritative register information. Responses to additional questions on income sharing among 1696 couples also allows us to analyses whether the intra-household distribution...

  20. Liquid sodium pool fires

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  1. Turbulence model for melt pool natural convection heat transfer

    International Nuclear Information System (INIS)

    Kelkar, K.M.; Patankar, S.V.

    1994-01-01

    Under severe reactor accident scenarios, pools of molten core material may form in the reactor core or in the hemispherically shaped lower plenum of the reactor vessel. Such molten pools are internally heated due to the radioactive decay heat that gives rise to buoyant flows in the molten pool. The flow in such pools is strongly influenced by the turbulent mixing because the expected Rayleigh numbers under accidents scenarios are very high. The variation of the local heat flux over the boundaries of the molten pools are important in determining the subsequent melt progression behavior. This study reports results of an ongoing effort towards providing a well validated mathematical model for the prediction of buoyant flow and heat transfer in internally heated pool under conditions expected in severe accident scenarios

  2. Using Item Response Theory to Develop a 60-Item Representation of the NEO PI-R Using the International Personality Item Pool: Development of the IPIP-NEO-60.

    Science.gov (United States)

    Maples-Keller, Jessica L; Williamson, Rachel L; Sleep, Chelsea E; Carter, Nathan T; Campbell, W Keith; Miller, Joshua D

    2017-10-31

    Given advantages of freely available and modifiable measures, an increase in the use of measures developed from the International Personality Item Pool (IPIP), including the 300-item representation of the Revised NEO Personality Inventory (NEO PI-R; Costa & McCrae, 1992a ) has occurred. The focus of this study was to use item response theory to develop a 60-item, IPIP-based measure of the Five-Factor Model (FFM) that provides equal representation of the FFM facets and to test the reliability and convergent and criterion validity of this measure compared to the NEO Five Factor Inventory (NEO-FFI). In an undergraduate sample (n = 359), scores from the NEO-FFI and IPIP-NEO-60 demonstrated good reliability and convergent validity with the NEO PI-R and IPIP-NEO-300. Additionally, across criterion variables in the undergraduate sample as well as a community-based sample (n = 757), the NEO-FFI and IPIP-NEO-60 demonstrated similar nomological networks across a wide range of external variables (r ICC = .96). Finally, as expected, in an MTurk sample the IPIP-NEO-60 demonstrated advantages over the Big Five Inventory-2 (Soto & John, 2017 ; n = 342) with regard to the Agreeableness domain content. The results suggest strong reliability and validity of the IPIP-NEO-60 scores.

  3. Pool gateway seal

    International Nuclear Information System (INIS)

    Starr, J.A.; Steinert, L.A.

    1983-01-01

    A device for sealing a gateway between interconnectable pools in a nuclear facility comprising a frame supporting a liquid impermeable sheet positioned in a u-shaped gateway between the pools. An inflatable tube carried in a channel in the periphery of the frame and adjoining the gateway provides a seal therebetween when inflated. A restraining arrangement on the bottom edge of the frame is releasably engagable with an adjacent portion of the gateway to restrict the movement of the frame in the u-shaped gateway upon inflation of the tube, thereby enhancing the seal. The impermeable sheet is formed of an elastomer and thus is conformable to a liquid permeable supportive wall upon application of liquid pressure to the side of the sheet opposite the wall

  4. Backfitting swimming pool reactors

    International Nuclear Information System (INIS)

    Roebert, G.A.

    1978-01-01

    Calculations based on measurements in a critical assembly, and experiments to disclose fuel element surface temperatures in case of accidents like stopping of primary coolant flow during full power operation, have shown that the power of the swimming pool type research reactor FRG-2 (15 MW, operating since 1967) might be raised to 21 MW within the present rules of science and technology, without major alterations of the pool buildings and the cooling systems. A backfitting program is carried through to adjust the reactor control systems of FRG-2 and FRG-1 (5 MW, housed in the same reactor hall) to the present safety rules and recommendations, to ensure FRG-2 operation at 21 MW for the next decade. (author)

  5. Fuel assembly storage pool

    International Nuclear Information System (INIS)

    Hiranuma, Hiroshi.

    1976-01-01

    Object: To remove limitation of the number of storage of fuel assemblies to increase the number of storage thereof so as to relatively reduce the water depth required for shielding radioactive rays. Structure: Fuel assembly storage rack containers for receiving a plurality of spent fuel assembly racks are stacked in multi-layer fashion within a storage pool filled with water for shielding radioactive rays and removing heat. (Furukawa, Y.)

  6. CERN Electronics Pool presentations

    CERN Multimedia

    2011-01-01

    The CERN Electronics Pool has organised a series of presentations in collaboration with oscilloscope manufacturers. The last one will take place according to the schedule below.   Time will be available at the end of the presentation to discuss your personal needs. The Agilent presentation had to be postponed and will be organised later. -     Lecroy: Thursday, 24 November 2011, in 530-R-030, 14:00 to 16:30.

  7. Nuclear Insurance Pools: World-wide Practice and Prospective

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2000-01-01

    The following paper explains why Nuclear Insurance Pools were established, how they operate and what insurance protection they offer to the operations of nuclear installations. It will be shown that the clear interrelationship of the Pool-insurance operations, both on a national and an international level, has resulted in a transparency of each individual Pool-Member's exposure, which enables him to make the highest possible commitment to nuclear risks. Finally, some views will be given as regards the future prospective for the long proven method of pooling this particularly sensitive class of business. (author)

  8. Swimming Pools and Molluscum Contagiosum

    Science.gov (United States)

    ... Travelers’ Health: Smallpox & Other Orthopoxvirus-Associated Infections Poxvirus Swimming Pools Recommend on Facebook Tweet Share Compartir The ... often ask if molluscum virus can spread in swimming pools. There is also concern that it can ...

  9. Pool-type reactor

    International Nuclear Information System (INIS)

    Hopkins, S.R.

    1977-01-01

    This invention relates to a pool nuclear reactor fitted with a perfected system to raise the buckets into a vertical position at the bottom of a channel. This reactor has an inclined channel to guide a bucket containing a fuel assembly to introduce it into the reactor jacket or extract it therefrom and a damper at the bottom of the channel to stop the drop of the bucket. An upright vertically movable rod has a horizontally articulated arm with a hook. This can pivot to touch a radial lug on the bucket and pivot the bucket around its base in a vertical position, when the rod moves up [fr

  10. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Science.gov (United States)

    2013-03-26

    ... Energy Conservation Code. International Existing Building Code. International Fire Code. International... Code. International Property Maintenance Code. International Residential Code. International Swimming Pool and Spa Code International Wildland-Urban Interface Code. International Zoning Code. ICC Standards...

  11. Studies of highly ionized atoms using internal conversion: 197Au, 57Fe; electric monopole transitions in 40Ca, 42Ca, and 44Ca

    International Nuclear Information System (INIS)

    Ulrickson, M.A.

    1975-01-01

    By using heavy-ion reactions, highly ionized electronic states of atoms may be produced. The interaction between excited nuclear levels and the surrounding atomic electrons via internal conversion allows the nucleus to be used as a probe of the electronic structure of the highly ionized atoms. Studies of such atoms were undertaken for strongly internally converted nuclear levels in 197 Au and 57 Fe. The nuclear levels were Coulomb excited by using 16 O and 32 S beams. Simultaneous measurement of the lifetime of the 77-keV state of 197 Au in both neutral gold atoms and gold atoms with mean charge +10 resulted in a measured change in the internal conversion coefficient of Δalpha/alpha equals - 1.7 +- 3.0)10 -3 . This result is consistent with calculations using a Hartree-Fock--Slater program. Measurements of the electric monopole strengths for 0 + → 0 + transitions were undertaken to determine the amount of core-deformation in calcium nuclei. The E0 strengths for the decays of the 0 + states at 5.21 MeV in 40 C, 1.84 MeV in 42 Ca, and 1.88 MeV in 44 Ca were observed. The branching ratios for the subsequent E0 pair decays were measured by observing the coincident annihilation radiation from the e + member of the pair in coincidence with protons feeding the state in the cases of 42 Ca and 44 Ca, and by observing the actual coincident e + --e - pair together with protons feeding the state in the case of 40 Ca. The resulting E0 strengths (rho less than or equal to 0.06, rho = 0.34 +- 0.03, rho = 0.30 +- 0.10 for 40 Ca, 42 Ca, and 44 Ca respectively) agree with theoretical descriptions

  12. Battery Internal Temperature Estimation for LiFePO4 Battery Based on Impedance Phase Shift under Operating Conditions

    Directory of Open Access Journals (Sweden)

    Jiangong Zhu

    2017-01-01

    Full Text Available An impedance-based temperature estimation method is investigated considering the electrochemical non-equilibrium with short-term relaxation time for facilitating the vehicular application. Generally, sufficient relaxation time is required for battery electrochemical equilibrium before the impedance measurement. A detailed experiment is performed to investigate the regularity of the battery impedance in short-term relaxation time after switch-off current excitation, which indicates that the impedance can be measured and also has systematical decrement with the relaxation time growth. Based on the discussion of impedance variation in electrochemical perspective, as well as the monotonic relationship between impedance phase shift and battery internal temperature in the electrochemical equilibrium state, an exponential equation that accounts for both measured phase shift and relaxation time is established to correct the measuring deviation caused by electrochemical non-equilibrium. Then, a multivariate linear equation coupled with ambient temperature is derived considering the temperature gradients between the active part and battery surface. Equations stated above are all identified with the embedded thermocouple experimentally. In conclusion, the temperature estimation method can be a valuable alternative for temperature monitoring during cell operating, and serve the functionality as an efficient implementation in battery thermal management system for electric vehicles (EVs and hybrid electric vehicles (HEVs.

  13. Effect of Ovality in Inlet Pigtail Pipe Bends Under Combined Internal Pressure and In-Plane Bending for Ni-Fe-Cr B407 Material

    Directory of Open Access Journals (Sweden)

    Ramaswami P.

    2017-09-01

    Full Text Available The present paper makes an attempt to depict the effect of ovality in the inlet pigtail pipe bend of a reformer under combined internal pressure and in-plane bending. Finite element analysis (FEA and experiments have been used. An incoloy Ni-Fe-Cr B407 alloy material was considered for study and assumed to be elastic-perfectly plastic in behavior. The design of pipe bend is based on ASME B31.3 standard and during manufacturing process, it is challenging to avoid thickening on the inner radius and thinning on the outer radius of pipe bend. This geometrical shape imperfection is known as ovality and its effect needs investigation which is considered for the study. The finite element analysis (ANSYS-workbench results showed that ovality affects the load carrying capacity of the pipe bend and it was varying with bend factor (h. By data fitting of finite element results, an empirical formula for the limit load of inlet pigtail pipe bend with ovality has been proposed, which is validated by experiments.

  14. Environmental controls of C, N and P biogeochemistry in peatland pools.

    Science.gov (United States)

    Arsenault, Julien; Talbot, Julie; Moore, Tim R

    2018-08-01

    Pools are common in northern peatlands but studies have seldom focused on their nutrient biogeochemistry, especially in relation to their morphological characteristics and through seasons. We determined the environmental characteristics controlling carbon (C), nitrogen (N) and phosphorus (P) biogeochemistry in pools and assessed their evolution over the course of the 2016 growing season in a subboreal ombrotrophic peatland of eastern Canada. We showed that water chemistry variations in 62 pools were significantly explained by depth (81.9%) and the surrounding vegetation type (14.8%), but not by pool area or shape. Shallow pools had larger dissolved organic carbon (DOC) and total nitrogen (TN) concentrations and lower pH than deep pools, while pools surrounded by coniferous trees had more recalcitrant DOC than pools where vegetation was dominated by mosses. The influence of depth on pool biogeochemistry was confirmed by the seasonal survey of pools of different sizes with 47.1% of the variation in pool water chemistry over time significantly explained. Of this, 67.3% was explained by the interaction between time and pool size and 32.7% by pool size alone. P concentrations were small in all pools all summer long and combined with high N:P ratios, are indicative of P-limitation. Our results show that pool biogeochemistry is influenced by internal processes and highlight the spatial and temporal heterogeneity of nutrient biogeochemistry in ombrotrophic peatlands. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. An internal magnetic field strategy to reuse pulverized active materials for high performance: a magnetic three-dimensional ordered macroporous TiO2/CoPt/α-Fe2O3 nanocomposite anode.

    Science.gov (United States)

    Tang, Yiping; Hong, Liang; Li, Jiquan; Hou, Guangya; Cao, Huazhen; Wu, Liankui; Zheng, Guoqu; Wu, Qingliu

    2017-05-09

    A ferromagnetic three-dimensional ordered macroporous TiO 2 /CoPt/α-Fe 2 O 3 (3DOMTCF) nanocomposite was synthesized via a sol-gel approach templated by poly(methyl methacrylate) (PMMA) microspheres. After magnetization, it exhibited an extremely high reversible capacity and a long cycle life, which were ascribed to the internal magnetic field for reusing pulverized active materials and its unique structure.

  16. Model of large pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Fay, J.A. [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)]. E-mail: jfay@mit.edu

    2006-08-21

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables.

  17. Model of large pool fires

    International Nuclear Information System (INIS)

    Fay, J.A.

    2006-01-01

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables

  18. Design of hydrotherapy exercise pools.

    Science.gov (United States)

    Edlich, R F; Abidin, M R; Becker, D G; Pavlovich, L J; Dang, M T

    1988-01-01

    Several hydrotherapy pools have been designed specifically for a variety of aquatic exercise. Aqua-Ark positions the exerciser in the center of the pool for deep-water exercise. Aqua-Trex is a shallow underwater treadmill system for water walking or jogging. Swim-Ex generates an adjustable laminar flow that permits swimming without turning. Musculoskeletal conditioning can be accomplished in the above-ground Arjo shallow-water exercise pool. A hydrotherapy pool also can be custom designed for musculoskeletal conditioning in its shallow part and cardiovascular conditioning in a deeper portion of the pool. Regardless of the type of exercise, there is general agreement that the specific exercise conducted in water requires significantly more energy expenditure than when the same exercise is performed on land.

  19. Electricity prices and generator behaviour in gross pool electricity markets

    International Nuclear Information System (INIS)

    O'Mahoney, Amy; Denny, Eleanor

    2013-01-01

    Electricity market liberalisation has become common practice internationally. The justification for this process has been to enhance competition in a market traditionally characterised by statutory monopolies in an attempt to reduce costs to end-users. This paper endeavours to see whether a pool market achieves this goal of increasing competition and reducing electricity prices. Here the electricity market is set up as a sealed bid second price auction. Theory predicts that such markets should result with firms bidding their marginal cost, thereby resulting in an efficient outcome and lower costs to consumers. The Irish electricity system with a gross pool market experiences among the highest electricity prices in Europe. Thus, we analyse the Irish pool system econometrically in order to test if the high electricity prices seen there are due to participants bidding outside of market rules or out of line with theory. Overall we do not find any evidence that the interaction between generator and the pool in the Irish electricity market is not efficient. Thus, the pool element of the market structure does not explain the high electricity prices experienced in Ireland. - Highlights: • We consider whether a gross pool achieves competitive behaviour. • We analyse the Irish pool system econometrically. • Results indicate the Irish pool system appears to work efficiently. • Generators appear to be bidding appropriately

  20. Analysis of natural convection in volumetrically-heated melt pools

    International Nuclear Information System (INIS)

    Sehgal, B.R.; Dinh, T.N.; Nourgaliev, R.R.

    1996-12-01

    Results of series of studies on natural convection heat transfer in decay-heated core melt pools which form in a reactor lower plenum during the progression of a core meltdown accident are described. The emphasis is on modelling and prediction of turbulent heat transfer characteristics of natural convection in a liquid pool with an internal energy source. Methods of computational fluid dynamics, including direct numerical simulation, were applied for investigation

  1. Analysis of natural convection in volumetrically-heated melt pools

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Dinh, T.N.; Nourgaliev, R.R. [Royal Inst. of Tech., Stockholm (Sweden). Div. of Nuclear Power Safety

    1996-12-01

    Results of series of studies on natural convection heat transfer in decay-heated core melt pools which form in a reactor lower plenum during the progression of a core meltdown accident are described. The emphasis is on modelling and prediction of turbulent heat transfer characteristics of natural convection in a liquid pool with an internal energy source. Methods of computational fluid dynamics, including direct numerical simulation, were applied for investigation. Refs, figs, tabs.

  2. Screen-Printed Electrode Modified by Bismuth /Fe3O4 Nanoparticle/Ionic Liquid Composite Using Internal Standard Normalization for Accurate Determination of Cd(II in Soil

    Directory of Open Access Journals (Sweden)

    Hui Wang

    2017-12-01

    Full Text Available The quality and safety of agricultural products are threatened by heavy metal ions in soil, which can be absorbed by the crops, and then accumulated in the human body through the food chain. In this paper, we report a low-cost and easy-to-use screen-printed electrode (SPE for cadmium ion (Cd(II detection based on differential pulse voltammetry (DPV, which decorated with ionic liquid (IL, magnetite nanoparticle (Fe3O4, and deposited a bismuth film (Bi. The characteristics of Bi/Fe3O4/ILSPE were investigated using scanning electron microscopy, cyclic voltammetry, impedance spectroscopy, and linear sweep voltammetry. We found that the sensitivity of SPE was improved dramatically after functionalized with Bi/Fe3O4/IL. Under optimized conditions, the concentrations of Cd(II are linear with current responses in a range from 0.5 to 40 µg/L with the lowest detection limit of 0.05 µg/L (S/N = 3. Additionally, the internal standard normalization (ISN was used to process the response signals of Bi/Fe3O4/ILSPE and established a new linear equation. For detecting three different Cd(II concentrations, the root-mean-square error using ISN (0.25 is lower than linear method (0.36. Finally, the proposed electrode was applied to trace Cd(II in soil samples with the recovery in the range from 91.77 to 107.83%.

  3. Estimation of the algal-available phosphorus pool in sediments of a large, shallow eutrophic lake (Taihu, China) using profiled SMT fractional analysis

    International Nuclear Information System (INIS)

    Zhu Mengyuan; Zhu Guangwei; Li Wei; Zhang Yunlin; Zhao Linlin; Gu Zhao

    2013-01-01

    Because large, shallow lakes are heavily influenced by wind–wave disturbance, it is difficult to estimate internal phosphorus load using traditional methods. To estimate the potential contribution of phosphorus from sediment to overlying water in eutrophic Lake Taihu, phosphorus fractions of surface and deep layer sediments were quantified and analyzed for algal bloom potential using a Standard Measurements and Testing (SMT) sequential extraction method and incubation experiments. Phosphorus bound to Fe, Al and Mn oxides and hydroxides (Fe–P) and organic phosphorus (OP) were to be found bioactive. The difference in Fe–P and OP contents between surface and deep layers equates to the sediment pool of potentially algal-available phosphorus. This pool was estimated at 5168 tons for the entire lake and was closely related to pollution input and algal blooms. Profiled SMT fractionation analysis is thus a potentially useful tool for estimating internal phosphorus loading in large, shallow lakes. - Highlights: ► We used profiled sediment P activity by SMT fractionation to evaluate the P release potential in large and shallow lakes. ► We built the relationship between sediment SMT fractionations of P and the P release by algal bloom degradation process. ► We discussed the supporting mechanism of sediment P release to Microcystis algal bloom in a large and shallow lake. ► We discussed the nutrient control strategy of algal bloom in shallow lakes in highly human activities disturbance catchment. - Profiled SMT fractional analysis of internal phosphorus pool in large, shallow lake.

  4. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  5. Pooling and correlated neural activity

    Directory of Open Access Journals (Sweden)

    Robert Rosenbaum

    2010-04-01

    Full Text Available Correlations between spike trains can strongly modulate neuronal activity and affect the ability of neurons to encode information. Neurons integrate inputs from thousands of afferents. Similarly, a number of experimental techniques are designed to record pooled cell activity. We review and generalize a number of previous results that show how correlations between cells in a population can be amplified and distorted in signals that reflect their collective activity. The structure of the underlying neuronal response can significantly impact correlations between such pooled signals. Therefore care needs to be taken when interpreting pooled recordings, or modeling networks of cells that receive inputs from large presynaptic populations. We also show that the frequently observed runaway synchrony in feedforward chains is primarily due to the pooling of correlated inputs.

  6. Thermophysical modeling of volatile fission product release from a debris pool

    International Nuclear Information System (INIS)

    Yun, J. I.; Suh, K. Y.; Kang, C. S.

    1999-01-01

    A model is described for fission product release from the debris pool in the lower plenum of the reactor pressure vessel. In the pool, turbulent natural convection flow is formed due to homogeneous internal heat generation. Using the best-known correlations, heat transfer at the curved bottom and the top of the pool may be calculated. Volatile fission product gases in the pool nucleate and diffuse to bubbles. Both the homogeneous nucleation and heterogeneous nucleation are considered. The bubble nucleation, growth, coalescence and loss due to rise is modeled pursuant to bubble dynamics. If the pressure and temperature of the pool are very high, homogeneous nucleation that accounts for effect of decrease in the pool pressure can occur. The effect of the bubble-to-pool interfacial tension and the pool pressure on the nucleation rate is investigated in this work

  7. Grundfoss: Chlorination of Swimming Pools

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Hogan, John; Andreassen, Viggo

    1998-01-01

    Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools.......Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools....

  8. Sustainability of common pool resources

    OpenAIRE

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepales...

  9. Fe65-PTB2 Dimerization Mimics Fe65-APP Interaction

    Directory of Open Access Journals (Sweden)

    Lukas P. Feilen

    2017-05-01

    Full Text Available Physiological function and pathology of the Alzheimer’s disease causing amyloid precursor protein (APP are correlated with its cytosolic adaptor Fe65 encompassing a WW and two phosphotyrosine-binding domains (PTBs. The C-terminal Fe65-PTB2 binds a large portion of the APP intracellular domain (AICD including the GYENPTY internalization sequence fingerprint. AICD binding to Fe65-PTB2 opens an intra-molecular interaction causing a structural change and altering Fe65 activity. Here we show that in the absence of the AICD, Fe65-PTB2 forms a homodimer in solution and determine its crystal structure at 2.6 Å resolution. Dimerization involves the unwinding of a C-terminal α-helix that mimics binding of the AICD internalization sequence, thus shielding the hydrophobic binding pocket. Specific dimer formation is validated by nuclear magnetic resonance (NMR techniques and cell-based analyses reveal that Fe65-PTB2 together with the WW domain are necessary and sufficient for dimerization. Together, our data demonstrate that Fe65 dimerizes via its APP interaction site, suggesting that besides intra- also intermolecular interactions between Fe65 molecules contribute to homeostatic regulation of APP mediated signaling.

  10. Fe65-PTB2 Dimerization Mimics Fe65-APP Interaction.

    Science.gov (United States)

    Feilen, Lukas P; Haubrich, Kevin; Strecker, Paul; Probst, Sabine; Eggert, Simone; Stier, Gunter; Sinning, Irmgard; Konietzko, Uwe; Kins, Stefan; Simon, Bernd; Wild, Klemens

    2017-01-01

    Physiological function and pathology of the Alzheimer's disease causing amyloid precursor protein (APP) are correlated with its cytosolic adaptor Fe65 encompassing a WW and two phosphotyrosine-binding domains (PTBs). The C-terminal Fe65-PTB2 binds a large portion of the APP intracellular domain (AICD) including the GYENPTY internalization sequence fingerprint. AICD binding to Fe65-PTB2 opens an intra-molecular interaction causing a structural change and altering Fe65 activity. Here we show that in the absence of the AICD, Fe65-PTB2 forms a homodimer in solution and determine its crystal structure at 2.6 Å resolution. Dimerization involves the unwinding of a C-terminal α-helix that mimics binding of the AICD internalization sequence, thus shielding the hydrophobic binding pocket. Specific dimer formation is validated by nuclear magnetic resonance (NMR) techniques and cell-based analyses reveal that Fe65-PTB2 together with the WW domain are necessary and sufficient for dimerization. Together, our data demonstrate that Fe65 dimerizes via its APP interaction site, suggesting that besides intra- also intermolecular interactions between Fe65 molecules contribute to homeostatic regulation of APP mediated signaling.

  11. Seismic analysis of large pools

    Energy Technology Data Exchange (ETDEWEB)

    Dong, R.G.; Tokarz, F.J.

    1976-11-17

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated.

  12. Seismic analysis of large pools

    International Nuclear Information System (INIS)

    Dong, R.G.; Tokarz, F.J.

    1976-01-01

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated

  13. LCG Persistency Framework (POOL, CORAL, COOL) - Status and Outlook

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The LCG Persistency Framework consists of three software packages (POOL, CORAL and COOL) that address the data access requirements of the LHC experiments in several different areas. The project is the result of the collaboration between the CERN IT Department and the three experiments (ATLAS, CMS and LHCb) that are using some or all of the Persistency Framework components to access their data. The POOL package is a hybrid technology store for C++ objects, using a mixture of streaming and relational technologies to implement both object persistency and object metadata catalogs and collections. POOL provides generic components that can be used by the experiments to store both their event data and their conditions data. The CORAL package is an abstraction layer with an SQL-free API for accessing data stored using relational database technologies. It is used directly by experiment-specific applications and internally by both COOL and POOL. The COOL package provides specific software components and tools for the h...

  14. Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool

    OpenAIRE

    Font-Ribera, Laia; Kogevinas, Manolis; Zock, Jan-Paul; G?mez, Federico P.; Barreiro, Esther; Nieuwenhuijsen, Mark J.; Fernandez, Pilar; Lourencetti, Carolina; P?rez-Olabarr?a, Maitane; Bustamante, Mariona; Marcos, Ricard; Grimalt, Joan O.; Villanueva, Cristina M.

    2010-01-01

    Background Swimming in chlorinated pools involves exposure to disinfection by-products (DBPs) and has been associated with impaired respiratory health. Objectives We evaluated short-term changes in several respiratory biomarkers to explore mechanisms of potential lung damage related to swimming pool exposure. Methods We measured lung function and biomarkers of airway inflammation [fractional exhaled nitric oxide (FeNO), eight cytokines, and vascular endothelial growth factor (VEGF) in exhaled...

  15. International

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    This rubric reports on 10 short notes about international economical facts about nuclear power: Electricite de France (EdF) and its assistance and management contracts with Eastern Europe countries (Poland, Hungary, Bulgaria); Transnuclear Inc. company (a 100% Cogema daughter company) acquired the US Vectra Technologies company; the construction of the Khumo nuclear power plant in Northern Korea plays in favour of the reconciliation between Northern and Southern Korea; the delivery of two VVER 1000 Russian reactors to China; the enforcement of the cooperation agreement between Euratom and Argentina; Japan requested for the financing of a Russian fast breeder reactor; Russia has planned to sell a floating barge-type nuclear power plant to Indonesia; the control of the Swedish reactor vessels of Sydkraft AB company committed to Tractebel (Belgium); the renewal of the nuclear cooperation agreement between Swiss and USA; the call for bids from the Turkish TEAS electric power company for the building of the Akkuyu nuclear power plant answered by three candidates: Atomic Energy of Canada Limited (AECL), Westinghouse (US) and the French-German NPI company. (J.S.)

  16. A synthetic system links FeFe-hydrogenases to essential E. coli sulfur metabolism

    Directory of Open Access Journals (Sweden)

    Grandl Gerald

    2011-05-01

    Full Text Available Abstract Background FeFe-hydrogenases are the most active class of H2-producing enzymes known in nature and may have important applications in clean H2 energy production. Many potential uses are currently complicated by a crucial weakness: the active sites of all known FeFe-hydrogenases are irreversibly inactivated by O2. Results We have developed a synthetic metabolic pathway in E. coli that links FeFe-hydrogenase activity to the production of the essential amino acid cysteine. Our design includes a complementary host strain whose endogenous redox pool is insulated from the synthetic metabolic pathway. Host viability on a selective medium requires hydrogenase expression, and moderate O2 levels eliminate growth. This pathway forms the basis for a genetic selection for O2 tolerance. Genetically selected hydrogenases did not show improved stability in O2 and in many cases had lost H2 production activity. The isolated mutations cluster significantly on charged surface residues, suggesting the evolution of binding surfaces that may accelerate hydrogenase electron transfer. Conclusions Rational design can optimize a fully heterologous three-component pathway to provide an essential metabolic flux while remaining insulated from the endogenous redox pool. We have developed a number of convenient in vivo assays to aid in the engineering of synthetic H2 metabolism. Our results also indicate a H2-independent redox activity in three different FeFe-hydrogenases, with implications for the future directed evolution of H2-activating catalysts.

  17. 21 CFR 1250.89 - Swimming pools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Swimming pools. 1250.89 Section 1250.89 Food and... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.89 Swimming pools. (a) Fill and draw swimming pools shall not be installed or used. (b) Swimming pools of the recirculation type shall be...

  18. Patent pools: Intellectual property rights and competition.

    NARCIS (Netherlands)

    Rodriguez, V.F.

    2010-01-01

    Patent pools do not correct all problems associated with patent thickets. In this respect, patent pools might not stop the outsider problem from striking pools. Moreover, patent pools can be expensive to negotiate, can exclude patent holders with smaller numbers of patents or enable a group of major

  19. Efficient pooling designs for library screening

    OpenAIRE

    Bruno, William J.; Knill, Emanuel; Balding, David J.; Bruce, D. C.; Doggett, N. A.; Sawhill, W. W.; Stallings, R. L.; Whittaker, Craig C.; Torney, David C.

    1994-01-01

    We describe efficient methods for screening clone libraries, based on pooling schemes which we call ``random $k$-sets designs''. In these designs, the pools in which any clone occurs are equally likely to be any possible selection of $k$ from the $v$ pools. The values of $k$ and $v$ can be chosen to optimize desirable properties. Random $k$-sets designs have substantial advantages over alternative pooling schemes: they are efficient, flexible, easy to specify, require fewer pools, and have er...

  20. EP BICYCLE POOL - VIGNETTES 2002

    CERN Multimedia

    EP-SMI Help Desk

    2002-01-01

    The vignettes (insurance certificates) for 2002 become obligatory from 1 June. If you have a bicycle from the EP Pool, please bring it to the EP-SMI Help Desk (Building 124) on any working day up to 31 May between 8h.30 - 12h.00 or 13h.30 - 17h.30. EP-SMI Help Desk

  1. Sculpting the Barnyard Gene Pool

    Science.gov (United States)

    Childers, Gina; Wolfe, Kim; Dupree, Alan; Young, Sheila; Caver, Jessica; Quintanilla, Ruby; Thornton, Laura

    2016-01-01

    Project-based learning (PBL) takes student engagement to a higher level through reflective collaboration, inquiry, critical thinking, problem solving, and personal relevance. This article explains how six high school teachers developed an interconnected, interdisciplinary STEM-focused PBL called "Sculpting the Barnyard Gene Pool." The…

  2. Natural convection heat transfer in the molten metal pool

    International Nuclear Information System (INIS)

    Park, R.J.; Kim, S.B.; Kim, H.D.; Choi, S.M.

    1997-01-01

    Analytical studies using the FLOW-3D computer program have been performed on natural convection heat transfer of a high density molten metal pool, in order to evaluate the coolability of the corium pool. The FLOW-3D results on the temperature distribution and the heat transfer rate in the molten metal pool region have been compared and evaluated with the experimental data. The FLOW-3D results have shown that the developed natural convection flow contributes to the solidified crust formation of the high density molten metal pool. The present FLOW-3D results, on the relationship between the Nusselt number and the Rayleigh number in the molten metal pool region, are more similar to the calculated results of Globe and Dropkin's correlation than any others. The natural convection heat transfer in the low aspect ratio case is more substantial than that in the high aspect ratio case. The FLOW-3D results, on the temperature profile and on the heat transfer rate in the molten metal pool region, are very similar to the experimental data. The heat transfer rate of the internal heat generation case is higher than that of the bottom heating case at the same heat supply condition. (author)

  3. Impact of Internal and External Factors on EBC-pH and FeNO Changes in Humans Following Challenge with Ethyl Acrylate.

    Science.gov (United States)

    Hoffmeyer, F; Sucker, K; Berresheim, H; Monsé, C; Jettkant, B; Beine, A; Raulf, M; Bünger, J; Brüning, T

    2017-01-01

    Acute effects of ethyl acrylate exposure at 5 ppm for 4 h include changes of pH in exhaled breath condensate (EBC-pH) and exhaled nitric oxide (FeNO). So far, few data have been reported for atopic persons or the impact of the exposure conditions on biomarkers, e.g., constant versus variable application of irritants. Nine atopic and eighteen healthy volunteers without bronchial hyperresponsiveness were exposed for 4 h to ethyl acrylate concentrations of 0.05 ppm (sham), 5 ppm (constant concentration), and 0-10 ppm (variable, mean concentration of 5 ppm) in an exposure laboratory. A positive atopic status was defined according to specific IgE concentrations to common inhalant allergens (sx1 ≥ 0.35 kU/L). Biomarker levels were assessed before and after challenge and adjusted for levels after sham exposure (net response). Ethyl acrylate at constant, but not at variable concentrations induced a significant change in the net responses of EBC-pH and FeNO. Concerning FeNO, this could be observed only for atopic persons. The changes of biomarker levels were related to their baseline values. Biomarker responses to challenge with ethyl acrylate may be influenced by the patterns of application as well as baseline airway inflammation and atopic status of the volunteers.

  4. Software for the Design of Swimming Pool Dehumidifiers Units

    Science.gov (United States)

    Rubina, Aleš; Blasinski, Petr; Tesař, Zdeněk

    2013-06-01

    The article deals with the description and solution of physical phenomena taking place during evaporation of water. The topicality of the theme is given a number of built indoor swimming pool and wellness centers at present. In addressing HVAC systems serving these areas, it is necessary to know the various design parameters in the interior including the water temperature as the pool temperature and humidity. Following is a description of the calculation module, air handling units, including optimizing the settings of the physical changes in order to ensure the lowest energy consumption for air treatment and required maintaining internal microclimate parameters.

  5. Fe and Cu isotope mass balances in the human body

    Science.gov (United States)

    Balter, V.; Albarede, F.; Jaouen, K.

    2011-12-01

    The ranges of the Fe and Cu isotope compositions in the human body are large, i.e. ~3% and ~2%, respectively. Both isotopic fractionations appear to be mainly controlled by redox conditions. The Fe and Cu isotope compositions of the tissues analyzed so far plot on a mixing hyperbolae between a reduced and an oxidized metals pools. The reduced metals pool is composed by erythrocytes, where Fe is bounded to hemoglobin as Fe(II) and Cu to superoxide-dismutase as Cu(I). The oxidized metals pool is composed by hepatocytes, where Fe and Cu are stored as Fe(III) ferritin and as Cu(II) ceruloplasmine, respectively. The position of each biological component in the δ56Fe-δ65Cu diagram therefore reflects the oxidation state of Fe and Cu of the predominant metal carrier protein and allows to quantify Fe and Cu fluxes between organs using mass balance calculations. For instance, serum and clot Fe and Cu isotope compositions show that current biological models of erythropoiesis violates mass conservation requirements, and suggest hidden Fe and Cu pathways during red blood cells synthesis. The results also show that a coupled Fe-Cu strong gender isotopic effect is observed in various organs. The isotopic difference between men and women is unlikely to be due to differential dietary uptake or endometrium loss, but rather reflects the effect of menstrual losses and a correlative solicitation of hepatic stores. We speculate that thorough studies of the metabolism of stable isotopes in normal conditions is a prerequisite for the understanding of the pathological dysregulations.

  6. "Ripples" in an Aluminum Pool?

    Science.gov (United States)

    Rohr, James; Wang, Si-Yin; Nesterenko, Vitali F.

    2018-05-01

    Our motivation for this article is for students to realize that opportunities for discovery are all around them. Discoveries that can still puzzle present day researchers. Here we explore an observation by a middle school student concerning the production of what appears to be water-like "ripples" produced in aluminum foil when placed between two colliding spheres. We both applaud and explore the student's reasoning that the ripples were formed in a melted aluminum pool.

  7. Sustainability of common pool resources.

    Science.gov (United States)

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepalese areas: (i) rural (non-capitalistic) and (ii) urban (capitalistic) areas. We find that a proportion of prosocial individuals in urban areas is lower than that in rural areas, and urban residents deplete resources more quickly than rural residents. The composition of proself and prosocial individuals in a group and the degree of capitalism are crucial in that an increase in prosocial members in a group and the rural dummy positively affect resource sustainability by 65% and 63%, respectively. Overall, this paper shows that when societies move toward more capitalistic environments, the sustainability of common pool resources tends to decrease with the changes in individual preferences, social norms, customs and views to others through human interactions. This result implies that individuals may be losing their coordination abilities for social dilemmas of resource sustainability in capitalistic societies.

  8. Flashing oscillation in pool water

    International Nuclear Information System (INIS)

    Takamasa, Tomoji; Kondo, Koichi; Hazuku, Tatsuya

    1996-01-01

    This paper presents an experimental study of high-pressure saturated water discharging into the pool water. The purpose of the experiment is to clarify the phenomena that occur in blow-down of high-pressure saturated water from the pressure vessel into the water-filled containment in the case of a wall-crack accident or a LOCA in an advanced reactor. The results revealed that a flashing oscillation (FO) occurs when high-pressure saturated water discharges into the pool water, under specified experimental settings. The range of the flashing oscillates between a point very close to and some distance from the vent hole. The pressures in the vent tube and pool water vary according to the flashing oscillation. The pressure oscillation and frequency of flashing position might be caused by the balancing action between the supply of saturated water, flashing at the control volume and its condensation on the steam-water interface. A linear analysis was conducted using a spherical flashing bubble model. The period of the flashing oscillation in the experiments can be explained by theoretical analysis

  9. Pressure supression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-10-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model developed in this work produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing is verified by comparing the model-predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  10. Pressure suppression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-01-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing model is verified by comparing the model predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  11. Technical Facilities Management, Loan Pool, and Calibration

    Science.gov (United States)

    Smith, Jacob

    2011-01-01

    My work at JPL for the SURF program began on June 11, 2012 with the Technical Facilities Management group (TFM). As well as TFM, I worked with Loan Pool and Metrology to help them out with various tasks. Unlike a lot of other interns, I did not have a specific project rather many different tasks to be completed over the course of the 10 weeks.The first task to be completed was to sort through old certification reports in 6 different boxes to locate reports that needed to be archived into a digital database. There were no reports within these boxes that needed to be archived but rather were to be shredded. The reports went back to the early 1980's and up to the early 2000's. I was looking for reports dated from 2002 to 2012

  12. Drop Impact on to Moving Liquid Pools

    Science.gov (United States)

    Muñoz-Sánchez, Beatriz Natividad; Castrejón-Pita, José Rafael; Castrejón-Pita, Alfonso Arturo; Hutchings, Ian M.

    2014-11-01

    The deposition of droplets on to moving liquid substrates is an omnipresent situation both in nature and industry. A diverse spectrum of phenomena emerges from this simple process. In this work we present a parametric experimental study that discerns the dynamics of the impact in terms of the physical properties of the fluid and the relative velocity between the impacting drop and the moving liquid pool. The behaviour ranges from smooth coalescence (characterized by little mixing) to violent splashing (generation of multiple satellite droplets and interfacial vorticity). In addition, transitional regimes such as bouncing and surfing are also found. We classify the system dynamics and show a parametric diagram for the conditions of each regime. This work was supported by the EPSRC (Grant EP/H018913/1), the Royal Society, Becas Santander Universidades and the International Relationships Office of the University of Extremadura.

  13. Correlation between microstructure and internal friction in a Zr41.2-Ti13.8-Cu12.5-Ni8- Be22.5-Fe2 bulk metallic glass

    International Nuclear Information System (INIS)

    Wang, Q.; Pelletier, J.M.; Da Dong, Y.; Ji, Y.F.; Xiu, H.

    2004-01-01

    The microstructural evolution in a Zr-Ti-Cu-Ni-Be-Fe bulk metallic glass (BMG) has been investigated by measurements of dynamical shear modulus and internal friction combined with other analytical methods such as differential scanning calorimetry (DSC), X-ray diffraction (XRD) and high resolution transmission electron microscopy (TEM). When heated from room temperature up to 873 K, the as-received BMG exhibits an exponential increase in internal friction accompanying the strong decrease of storage modulus and the presence of the first loss modulus peak during the dynamic glass transition, which can be well described using quasi-point defect model. The correlative changes of the mechanical response at higher temperature are associated with the crystallisation process of the supercooled liquid phase, which occurs in four different stages. It is shown that the main crystallisation process is completed in the first two stages. With further increasing temperature, the remaining amorphous phases crystallise and/or the metastable crystalline phases are transformed into the stable ones. Isothermal annealing were also performed at temperatures in the supercooled liquid region far below the onset temperature of the crystallisation process (T x ). Their influence on microstucture and internal friction behaviour of the BMG is also presented in this paper. The most striking result is that the internal friction is very sensitive to the local atomic short range ordering induced by the preheating treatment

  14. Human parvovirus PARV4 in plasma pools of Chinese origin.

    Science.gov (United States)

    Ma, Y-Y; Guo, Y; Zhao, X; Wang, Z; Lv, M-M; Yan, Q-P; Zhang, J-G

    2012-10-01

    Human parvovirus 4 (PARV4) is present in blood and blood products. As the presence and levels of PARV4 in Chinese source plasma pools have never been determined, we implemented real-time quantitative PCR to investigate the presence of PARV4 in source plasma pools in China. Results showed that 26·15% (51/195) of lots tested positive for PARV4. The amounts of DNA ranged from 2·83 × 10(3) copies/ml to 2·35×10(7) copies/ml plasma. The high level of PARV4 in plasma pools may pose a potential risk to recipients. Further studies on the pathogenesis of PARV4 are urgently required. © 2012 The Author(s). Vox Sanguinis © 2012 International Society of Blood Transfusion.

  15. CDC Study Finds Fecal Contamination in Pools

    Science.gov (United States)

    ... Communication (404) 639-3286 CDC study finds fecal contamination in pools A study of public pools done ... The E. coli is a marker for fecal contamination. Finding a high percentage of E. coli-positive ...

  16. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  17. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1984-03-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56

  18. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1982-01-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for nondestructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Material Research Collection and does not designate whether a sample is out on loan or in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56

  19. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  20. Heat and Fission Product Transport in a Molten U-Zr-O Pool With Crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2002-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry and the change of pool geometry during the numerical calculation was neglected. Results of the numerical calculation revealed that the peak temperature of the molten pool significantly decreased and most of the volatile fission products were released from the molten pool during the accident. (authors)

  1. International variability in 20 m shuttle run performance in children and youth: who are the fittest from a 50-country comparison? A systematic literature review with pooling of aggregate results.

    Science.gov (United States)

    Lang, Justin J; Tremblay, Mark S; Léger, Luc; Olds, Tim; Tomkinson, Grant R

    2018-02-01

    To describe and compare 20 m shuttle run test (20mSRT) performance among children and youth across 50 countries; to explore broad socioeconomic indicators that correlate with 20mSRT performance in children and youth across countries and to evaluate the utility of the 20mSRT as an international population health indicator for children and youth. A systematic review was undertaken to identify papers that explicitly reported descriptive 20mSRT (with 1-min stages) data on apparently healthy 9-17 year-olds. Descriptive data were standardised to running speed (km/h) at the last completed stage. Country-specific 20mSRT performance indices were calculated as population-weighted mean z-scores relative to all children of the same age and sex from all countries. Countries were categorised into developed and developing groups based on the Human Development Index, and a correlational analysis was performed to describe the association between country-specific performance indices and broad socioeconomic indicators using Spearman's rank correlation coefficient. Performance indices were calculated for 50 countries using collated data on 1 142 026 children and youth aged 9-17 years. The best performing countries were from Africa and Central-Northern Europe. Countries from South America were consistently among the worst performing countries. Country-specific income inequality (Gini index) was a strong negative correlate of the performance index across all 50 countries. The pattern of variability in the performance index broadly supports the theory of a physical activity transition and income inequality as the strongest structural determinant of health in children and youth. This simple and cost-effective assessment would be a powerful tool for international population health surveillance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  3. Preservation of Fe Isotope Proxies in the Rock Record

    Science.gov (United States)

    Johnson, C.; Beard, B.; Valley, J.; Valaas, E.

    2005-12-01

    Iron isotope variations provide powerful constraints on redox conditions and pathways involved during biogeochemical cycling of Fe in surface and near-surface environments. The relative isotopic homogeneity of igneous rocks and most bulk weathering products contrasts with the significant isotopic variations (4 per mil in 56Fe/54Fe) that accompany oxidation of Fe(II)aq, precipitation of sulfides, and reduction by bacteria. These isotopic variations often reflect intrinsic (equilibrium) Fe isotope fractionations between minerals and aqueous species whose interactions may be directly or indirectly catalyzed by bacteria. In addition, Fe isotope exchange may be limited between reactive Fe pools in low-temperature aqueous-sediment environments, fundamentally reflecting disequilibrium effects. In the absence of significant sulfide, dissimilatory Fe(III) reduction by bacteria produces relatively low 56Fe/54Fe ratios for Fe(II)aq and associated biogenic minerals such as magnetite and siderite. In contrast, Fe(II)aq that exchanges with Fe sulfides (FeS and pyrite) is relatively enriched in 56Fe/54Fe ratios. In modern and ancient environments, anoxic diagenesis tends to produce products that have low 56Fe/54Fe ratios, whereas oxidation of Fe(II)aq from hydrothermal sources tends to produce ferric Fe products that have high 56Fe/54Fe ratios. Redox cycling by bacteria tends to produce reactive ferric Fe reservoirs that have low 56Fe/54Fe ratios. Application of Fe isotopes as a proxy for redox conditions in the ancient rock record depends upon the preservation potential during metamorphism, given the fact that most Archean sedimentary sequences have been subjected to regional greenschist- to granulite-facies metamorphism. The 1.9 Ga banded iron formations (BIFs) of the Lake Superior region that are intruded by large ~1 Ga intrusions (e.g., Duluth gabbro) provide a test of the preservation potential for primary, low-temperature Fe isotope variations in sedimentary rocks. 56Fe/54

  4. Large-scale pool fires

    Directory of Open Access Journals (Sweden)

    Steinhaus Thomas

    2007-01-01

    Full Text Available A review of research into the burning behavior of large pool fires and fuel spill fires is presented. The features which distinguish such fires from smaller pool fires are mainly associated with the fire dynamics at low source Froude numbers and the radiative interaction with the fire source. In hydrocarbon fires, higher soot levels at increased diameters result in radiation blockage effects around the perimeter of large fire plumes; this yields lower emissive powers and a drastic reduction in the radiative loss fraction; whilst there are simplifying factors with these phenomena, arising from the fact that soot yield can saturate, there are other complications deriving from the intermittency of the behavior, with luminous regions of efficient combustion appearing randomly in the outer surface of the fire according the turbulent fluctuations in the fire plume. Knowledge of the fluid flow instabilities, which lead to the formation of large eddies, is also key to understanding the behavior of large-scale fires. Here modeling tools can be effectively exploited in order to investigate the fluid flow phenomena, including RANS- and LES-based computational fluid dynamics codes. The latter are well-suited to representation of the turbulent motions, but a number of challenges remain with their practical application. Massively-parallel computational resources are likely to be necessary in order to be able to adequately address the complex coupled phenomena to the level of detail that is necessary.

  5. Structural integrity assessment of HANARO pool cover

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo

    2001-11-01

    This report is for the seismic analysis and the structural integrity evaluation of HANARO Pool Cover in accordances with the requirement of the Technical Specification for Seismic Analysis of HANARO Pool Cover. For performing the seismic analysis and evaluating the structural integrity for HANARO Pool Cover, the finite element analysis model using ANSYS 5.7 was developed and the dynamic characteristics were analyzed. The seismic response spectrum analyses of HANARO Pool Cover under the design floor response spectrum loads of OBE and SSE were performed. The analysis results show that the stress values in HANARO Pool Cover for the seismic loads are within the ASME Code limits. It is also confirmed that the fatigue usage factor is less than 1.0. Therefore any damage on structural integrity is not expected when an HANARO Pool Cover is installed in the upper part of the reactor pool

  6. Magnetic Properties and Microstructure of FeOx/Fe/FePt and FeOx/FePt Films

    Directory of Open Access Journals (Sweden)

    Jai-Lin Tsai

    2013-01-01

    Full Text Available The Fe(6 nm/FePt film with perpendicular magnetization was deposited on the glass substrate. To study the oxygen diffusion effect on the coupling of Fe/FePt bilayer, the plasma oxidation with 0.5~7% oxygen flow ratio was performed during sputtered part of Fe layer and formed the FeOx(3 nm/Fe(3 nm/FePt trilayer. Two-step magnetic hysteresis loops were found in trilayer with oxygen flow ratio above 1%. The magnetization in FeOx and Fe/FePt layers was decoupled. The moments in FeOx layer were first reversed and followed by coupled Fe/FePt bilayer. The trilayer was annealed again at 500°C and 800°C for 3 minutes. When the FeOx(3 nm/Fe(3 nm/FePt trilayer was annealed at 500°C, the layers structure was changed to FeOx(6 nm/FePt bilayer due to oxygen diffusion. The hard-magnetic FeOx(6 nm/FePt film was coupled with single switching field. The FeOx/(disordered FePt layer structure was observed with further annealing at 800°C and presented soft-magnetic loop. In summary, the coupling between soft-magnetic Fe, FeOx layer, and hard-magnetic L10 FePt layer can be controlled by the oxygen diffusion behavior, and the oxidation of Fe layer was tuned by the annealing temperature. The ordered L10 FePt layer was deteriorated by oxygen and became disordered FePt when the annealed temperature was up to 800°C.

  7. PIV measurements of turbulent jet and pool mixing produced by a steam jet discharge in a subcooled water pool

    International Nuclear Information System (INIS)

    Choo, Yeon Jun; Song, Chul-Hwa

    2010-01-01

    This experimental research is on the fluid-dynamic features produced by a steam injection into a subcooled water pool. The relevant phenomena could often be encountered in water cooled nuclear power plants. Two major topics, a turbulent jet and the internal circulation produced by a steam injection, were investigated separately using a particle image velocimetry (PIV) as a non-intrusive optical measurement technique. Physical domains of both experiments have a two-dimensional axi-symmetric geometry of which the boundary and initial conditions can be readily and well defined. The turbulent jet experiments with the upward discharging configuration provide the parametric values for quantitatively describing a turbulent jet such as the self-similar velocity profile, central velocity decay, spreading rate, etc. And in the internal circulation experiments with the downward discharging configuration, typical flow patterns in a whole pool region are measured in detail, which reveals both the local and macroscopic characteristics of the mixing behavior in a pool. This quantitative data on the condensing jet-induced mixing behavior in a pool could be utilized as benchmarking for a CFD simulation of relevant phenomena.

  8. The pool chlorine hypothesis and asthma among boys.

    LENUS (Irish Health Repository)

    Cotter, A

    2012-01-31

    Swimming pool sanitation has largely been concerned with the microbiological quality of pool water, which is normally treated using a number of chlorine products. Recent studies have pointed to the potential hazards of chlorine by-products to the respiratory epithelium, particularly in indoor, poorly ventilated, pools. The aim of our study was to elucidate whether chronic exposure to indoor chlorinated swimming pools was associated with an increased likelihood of the development of asthma in boys. METHODS: The subjects were boys aged between 6 and 12 years. Data was collected by means of parental responses to a standardized asthma questionnaire (ISAAC: International Study of Asthma and Allergies in Childhood), supplemented with additional questions regarding frequency of attendance, number of years attendance, whether the child is a swimming team member. The questionnaire return rate was 71\\/% (n = 121). 23 boys were excluded on the basis that they had asthma before they started swimming (n = 97). There was a significant association between number of years a boy had been swimming and the likelihood of wheezing in the last 12 months (p = 0.009; OR = 1.351; 95% CI = 1.077-1.693) and diagnosed asthma (p = 0.046; OR = 1.299; 95% CI = 1.004-1.506). The greater the number the number of years a boy had been attending an indoor, chlorinated pool, the greater the likelihood of wheezing in the last 12 months or "had asthma". Age, parental smoking habits and being a swimming team member had no association with any of the asthma variables examined. Swimming pool attendance may be a risk factor in asthma in boys.

  9. Livermore pool-type reactor

    International Nuclear Information System (INIS)

    Mann, L.G.

    1977-01-01

    The Livermore Pool-Type Reactor (LPTR) has served a dual purpose since 1958--as an instrument for fundamental research and as a tool for measurement and calibration. Our early efforts centered on neutron-diffraction, fission, and capture gamma-ray studies. During the 1960's it was used for extensive calibration work associated with radiochemical and physical measurements on nuclear-explosive tests. Since 1970 the principal applications have been for trace-element measurements and radiation-damage studies. Today's research program is dominated by radiochemical studies of the shorter-lived fission products and by research on the mechanisms of radiation damage. Trace-element measurement for the National Uranium Resource Evaluation (NURE) program is the major measurement application today

  10. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  11. Arc-weld pool interactions

    International Nuclear Information System (INIS)

    Glickstein, S.S.

    1978-08-01

    The mechanisms involved in arc-weld pool interactions are extremely complex and no complete theory is presently available to describe much of the phenomena observed during welding. For the past several years, experimental and analytical studies have been undertaken at the Bettis Atomic Power Laboratory to increase basic understanding of the gas tungsten arc welding process. These studies have included experimental spectral analysis of the arc in order to determine arc temperature and analytical modeling of the arc and weld puddle. The investigations have been directed toward determining the cause and effects of variations in the energy distribution incident upon the weldment. In addition, the effect of weld puddle distortion on weld penetration was investigated, and experimental and analytical studies of weld process variables have been undertaken to determine the effects of the variables upon weld penetration and configuration. A review of the results and analysis of these studies are presented

  12. A Review of Selected International Aircraft Spares Pooling Programs: Lessons Learned for F-35 Spares Pooling

    Science.gov (United States)

    2016-01-01

    Applications Global Marketing Brochure, Eurofighter GmbH Case Study, September 2006. 39 The NAO is equivalent to the U.S. Government Accountability Office...www.publications.parliament.uk/pa/cm201011/cmselect/cmpubacc/860/860we01.htm IFS, IFS Applications Global Marketing Brochure, Eurofighter GmbH Case Study

  13. Estimation of heat transfer and heat source in a molten pool

    Energy Technology Data Exchange (ETDEWEB)

    Yun, J.I.; Suh, K.Y.; Kang, C.S. [Seoul National Univ., Dept. of Nuclear Engineering (Korea, Republic of)

    2001-07-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  14. Estimation of heat transfer and heat source in a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  15. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1986-08-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high-abundance, naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56. All requests for the loan of samples should be submitted with a summary of the purpose of the loan to: Iotope Distribution Office, Oak Ridge National Laboratory, P.O. Box X, Oak Ridge, Tennessee 37831. Requests from non-DOE contractors and from foreign institutions require DOE approval

  16. Guide for decontaminating swimming pool at schools

    International Nuclear Information System (INIS)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-01

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  17. Current operating practices of nuclear insurance pools

    International Nuclear Information System (INIS)

    O'Connell, J.M.

    1993-01-01

    This paper discusses the nuclear pooling system and co-operation between the pools, present practice and capacity, with a breakdown of the limits for third party liability and material damage. The author also describes the relationship between the pools and the nuclear operators (the policyholders), and concludes that the nuclear pools have been successful in serving the interests of their member companies, their policyholders and the governments as they have provided a stable insurance market by making available capacity in amounts that had never before been assembled and placed at risk in a single location. 2 tabs

  18. Guide for decontaminating swimming pool at schools

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-15

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  19. Structure for nuclear fuel storage pools

    International Nuclear Information System (INIS)

    Ebata, Sakae; Nichiei, Shinji.

    1979-01-01

    Purpose: To enable leak detection in nuclear fuel storage pools, as well as prevent external leakages while keeping the strength of the constructional structures. Constitution: Protection plates are provided around pool linear plates and a leak reception is provided to the bottom. Leakages are detected by leak detecting pipeways and the external leakages are prevented by collecting them in a detection area provided in the intermediate layer. Since ferro-reinforcements at the bottom wall of the pool are disconnected by the protection plate making it impossible to form the constructional body, body hunches are provided to the bottom wall of the pool for processing the ferro-reinforcements. (Yoshino, Y.)

  20. Oxidation kinetics of corium pool

    Energy Technology Data Exchange (ETDEWEB)

    Sulatsky, A.A., E-mail: andrei314@mail.ru [Alexandrov Research Institute of Technologies (NITI), Sosnovy Bor (Russian Federation); Smirnov, S.A. [D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (NIIEFA), St. Petersburg (Russian Federation); Granovsky, V.S.; Khabensky, V.B.; Krushinov, E.V.; Vitol, S.A.; Kotova, S.Yu. [Alexandrov Research Institute of Technologies (NITI), Sosnovy Bor (Russian Federation); Fischer, M.; Hellmann, S. [AREVA NP GmbH, Erlangen (Germany); Tromm, W.; Miassoedov, A. [Forschungzentrum Karlsruhe (FZK), Karlsruhe (Germany); Bottomley, D. [EUROPÄISCHE KOMMISSION, Joint Research Centre Institut für Transurane (ITU), Karlsruhe (Germany); Piluso, P. [CEA Cadarache-DEN/DTN/STRI, St.Paul-lez-Durance (France); Barrachin, M. [Institut de Radioprotection et Sûreté Nucléaire, St.Paul-lez-Durance (France)

    2013-09-15

    Highlights: • The analysis of experimental data on molten corium oxidation was been carried out. • The analysis has revealed the main factors influencing the oxidation kinetics. • The analysis was used for developing a qualitative analytical model. • The numerical modeling has confirmed the results of experimental data analysis. -- Abstract: Experimental, theoretical and numerical studies of oxidation kinetics of an open surface corium pool have been reported. The experiments have been carried out within OECD MASCA program and ISTC METCOR, METCOR-P and EVAN projects. It has been shown that the melt oxidation is controlled by an oxidant supply to the melt free surface from the atmosphere, not by the reducer supply from the melt. The project experiments have not detected any input of the zirconium oxidation kinetics into the process chemistry. The completed analysis puts forward a simple analytical model, which gives an explanation of the main features of melt oxidation process. The numerical modeling results are in good agreement with experimental data and theoretical considerations.

  1. Oxidation kinetics of corium pool

    International Nuclear Information System (INIS)

    Sulatsky, A.A.; Smirnov, S.A.; Granovsky, V.S.; Khabensky, V.B.; Krushinov, E.V.; Vitol, S.A.; Kotova, S.Yu.; Fischer, M.; Hellmann, S.; Tromm, W.; Miassoedov, A.; Bottomley, D.; Piluso, P.; Barrachin, M.

    2013-01-01

    Highlights: • The analysis of experimental data on molten corium oxidation was been carried out. • The analysis has revealed the main factors influencing the oxidation kinetics. • The analysis was used for developing a qualitative analytical model. • The numerical modeling has confirmed the results of experimental data analysis. -- Abstract: Experimental, theoretical and numerical studies of oxidation kinetics of an open surface corium pool have been reported. The experiments have been carried out within OECD MASCA program and ISTC METCOR, METCOR-P and EVAN projects. It has been shown that the melt oxidation is controlled by an oxidant supply to the melt free surface from the atmosphere, not by the reducer supply from the melt. The project experiments have not detected any input of the zirconium oxidation kinetics into the process chemistry. The completed analysis puts forward a simple analytical model, which gives an explanation of the main features of melt oxidation process. The numerical modeling results are in good agreement with experimental data and theoretical considerations

  2. 13 CFR 120.1708 - Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... United States. (c) SBA purchase of a Loan Interest. SBA will determine whether to purchase a Loan... reserves the right to purchase a Loan Interest from a Pool at any time. (d) Self-liquidating. A Pool... market conditions and program experience, and will publish any such change in the Federal Register. (h...

  3. Compact fuel storage rack for fuel pools

    International Nuclear Information System (INIS)

    Parras, F.; Louvat, J.P.

    1986-01-01

    ETS LEMER and FRAMATOME propose a new compact storage rack. This rack permits a considerable increase of the storage capacity of cooling pools. A short description of the structure and the components is presented, to propose racks that are: . Inalterable, . Compact, . Insensitive to earthquakes. Installation in pools already in operation is simplified by their light structure and the bearing device [fr

  4. The warm pool in the Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Vinayachandran, P.N.; Shetye, S.R.

    is larger and warmer, a peculiarity of the pool in the Indian Ocean is its seasonal variation. The surface area of the pool changes from 24 x 106 km2 in April to 8 x 106 km2 in September due to interaction with the southwest monsoon. The annual cycles of sea...

  5. Shedding Light on Dark Liquidity Pools

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2008-01-01

    This article reviews the recent developments on dark liquidity pools starting from the theoretical and empirical academic literature. The number of dark liquidity pools as well as their trading volume has grown substantially in the last couple of years. We highlight the incentives of providers as

  6. Risk factors for oligodendroglial tumors: a pooled international study

    DEFF Research Database (Denmark)

    McCarthy, Bridget J; Rankin, Kristin M; Aldape, Ken

    2011-01-01

    Oligodendroglial tumors are rare subtypes of brain tumors and are often combined with other glial tumors in epidemiological analyses. However, different demographic associations and clinical characteristics suggest potentially different risk factors. The purpose of this study was to investigate p...

  7. Big city consultants shut down our pool : a shocking community pool gets checked for stray voltage

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, P. [Power Line Systems Engineering Inc., Markham, ON (Canada)

    2009-12-15

    This article discussed an investigation conducted at a community pool where swimmers complained of receiving electrical shocks both in the pool and on the pool's deck area. Electrical measurements taken at the pool revealed current flows from the pool water to various points around the deck area. Measured current flow in the pool area was 30 amps even when the main pool service breaker was opened to shut off power to the entire facility. Thirty amps of primary neutral current was then measured on the primary side aerial neutral in front of the pool. A 10 amp primary feeder from the pool joined up with the complex's primary neutral wire to increase the neutral current to 40 amps. The combined 40 amps current then returned to the secondary side of a nearby utility transformer substation. The study showed that the underground wet low-resistance grounded surface area of the pool was attracting the 30 amps of utility current from the surrounding ground area. The local utility disconnected the primary and secondary neutral interconnection at the pool's main 600-volt step-down transformer. The pool deck was removed in order to install additional copper bonding grounds. In order to avert serious injuries, many experts propose that all electric utilities should be required by law to reconfigure their power systems to prevent primary power neutral currents from entering private buildings. 1 tab., 2 figs.

  8. Measurements in large pool fires with an actively cooled calorimeter

    International Nuclear Information System (INIS)

    Koski, J.A.; Wix, S.D.

    1995-01-01

    The pool fire thermal test described in Safety Series 6 published by the International Atomic Energy Agency (IAEA) or Title 10, Code of Federal Regulations, Part 71 (10CFR71) in the United States is one of the most difficult tests that a container for larger ''Type B'' quantities of nuclear materials must pass. If retests of a container are required, costly redesign and project delays can result. Accurate measurements and modeling of the pool fire environment will ultimately lower container costs by assuring that containers past the pool fire test on the first attempt. Experiments indicate that the object size or surface temperature of the container can play a role in determining local heat fluxes that are beyond the effects predicted from the simple radiative heat transfer laws. An analytical model described by Nicolette and Larson 1990 can be used to understand many of these effects. In this model a gray gas represents soot particles present in the flame structure. Close to the container surface, these soot particles are convectively and radiatively cooled and interact with incident energy from the surrounding fire. This cooler soot cloud effectively prevents some thermal radiation from reaching the container surface, reducing the surface heat flux below the value predicted by a transparent medium model. With some empirical constants, the model suggested by Nicolette and Larson can be used to more accurately simulate the pool fire environment. Properly formulated, the gray gas approaches also fast enough to be used with standard commercial computer codes to analyze shipping containers. To calibrate this type of model, accurate experimental measurements of radiative absorption coefficients, flame temperatures, and other parameters are necessary. A goal of the calorimeter measurements described here is to obtain such parameters so that a fast, useful design tool for large pool fires can be constructed

  9. Ripples in a superconducting tidal pool

    CERN Document Server

    Hudson, E

    2003-01-01

    The behaviour of electrons in a metal is often compared to that of water in a pool. An empty pool is like a material that has all of its electrons removed. As electrons are 'poured' into the metal, they first occupy the lowest energies available - the bottom of the pool - and eventually fill up to the Fermi energy, the top of the pool. At this point we no longer discuss electrons but quasiparticles. These are electrons that have modified properties due to their interactions within the material. Waves in a pool can be excited, and their properties will depend on the depth of the water. Similarly in a metal, quasiparticles behave like waves that have a material-dependent dispersion relation between their energy and their wavevector, which specifies their direction and wavelength. This simple analogy also hints at an indirect method of measuring the dispersion relation of a metal, and hence the myriad of properties that depend on it. (U.K.)

  10. Design and Construction of Pool Door for Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door.

  11. Design and Construction of Pool Door for Research Reactor

    International Nuclear Information System (INIS)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin

    2016-01-01

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door

  12. Pool scrubbing models for iodine components

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, K [Battelle Ingenieurtechnik GmbH, Eschborn (Germany)

    1996-12-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs.

  13. Pool scrubbing models for iodine components

    International Nuclear Information System (INIS)

    Fischer, K.

    1996-01-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs

  14. Investigation of Processes Controlling Elution of Solutes from Nonaqueous Phase Liquid (NAPL) Pools into Groundwater

    Science.gov (United States)

    Seyedabbasi, M.; Pirestani, K.; Holland, S. B.; Imhoff, P. T.

    2005-12-01

    Two major processes influencing the elution of solutes from porous media contaminated with nonaqueous phase liquids (NAPLs) are external mass transfer between the NAPL and groundwater and internal diffusion through NAPL ganglia and pools. There is a relatively large body of literature on the dissolution of single-species NAPLs. Less is known about the rates of elution of compounds dissolving from multicomponent NAPLs. We examined the mass transfer of one solute, 2,3-dimethyl-2-butanol (DMB) - a partitioning tracer, between groundwater and a dense NAPL - trichloroethylene (TCE). Diffusion cell experiments were used to measure the molecular diffusion coefficient of DMB in pure TCE and in porous media contaminated with a TCE pool. Measured diffusion coefficients were compared with empirical correlations (pure TCE) and a parallel resistance model (TCE pool). Based on the results from these analyses, a dimensionless Biot number was derived to express the ratio of the external rate of mass transfer from a NAPL pool to the internal rate of diffusion within the pool, which varies with NAPL saturation and NAPL-water partition coefficient. Biot numbers were then estimated for several laboratory scale experiments involving DMB transport between NAPL pools and groundwater. The estimated Biot numbers were in good agreement with experimental results. The expression for the Biot number developed here may be used to assess the processes controlling the elution of solutes from NAPL pools, which has implications on long-term predictions of solute dissolution from NAPLs in the field.

  15. Multiple Interfacial Fe3O4@BaTiO3/P(VDF-HFP) Core-Shell-Matrix Films with Internal Barrier Layer Capacitor (IBLC) Effects and High Energy Storage Density.

    Science.gov (United States)

    Zhou, Ling; Fu, Qiuyun; Xue, Fei; Tang, Xiahui; Zhou, Dongxiang; Tian, Yahui; Wang, Geng; Wang, Chaohong; Gou, Haibo; Xu, Lei

    2017-11-22

    Flexible nanocomposites composed of high dielectric constant fillers and polymer matrix have shown great potential for electrostatic capacitors and energy storage applications. To obtain the composited material with high dielectric constant and high breakdown strength, multi-interfacial composited particles, which composed of conductive cores and insulating shells and possessed the internal barrier layer capacitor (IBLC) effect, were adopted as fillers. Thus, Fe 3 O 4 @BaTiO 3 core-shell particles were prepared and loaded into the poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-HFP)) polymer matrix. As the mass fraction of core-shell fillers increased from 2.5 wt % to 30 wt %, the dielectric constant of the films increased, while the loss tangent remained at a low level (capacitor model was also adopted to interpret the efficiency of IBLC effects on the suppressed loss tangent and the superior breakdown strength. This work explored an effective approach to prepare dielectric nanocomposites for energy storage applications experimentally and theoretically.

  16. Simulation and optimization methods for logistics pooling in the outbound supply chain

    OpenAIRE

    Jesus Gonzalez-Feliu; Carlos Peris-Pla; Dina Rakotonarivo

    2010-01-01

    International audience; Logistics pooling and collaborative transportation systems are relatively new concepts in logistics research, but are very popular in practice. This communication proposes a conceptual framework for logistics and transportation pooling systems, as well as a simulation method for strategic planning optimization. This method is based on a twostep constructive heuristic in order to estimate for big instances the transportation and storage costs at a macroscopic level. Fou...

  17. Operation and maintenance techniques of pool and pool water purification system in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs.

  18. Operation and maintenance techniques of pool and pool water purification system in IMEF

    International Nuclear Information System (INIS)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs

  19. Swimming pool hydraulics and their significance for public pools. Bedeutung der Beckenhydraulik in oeffentlichen Schwimmbaedern

    Energy Technology Data Exchange (ETDEWEB)

    Gansloser, G

    1989-11-01

    The term of swimming pool hydraulics means the process of letting in and drawing off water to and from the pool while ensuring that no inadmissible water-borne contaminant concentrations will occur anywhere within the pool. Measurements were performed on a pool to study the significance of correct pool hydraulics. The author points out that a wrong water recirculation design will bring to nought the effects of an elaborate water treatment system; by contrast, poor pool water quality can be greatly improved by redesigning the pool water hydraulics approach. In principle, systems with with water inlet at one side and water outlet at the far side will fall short of hygienic requirements. (BWI).

  20. Studies of thermal stratification in water pool

    International Nuclear Information System (INIS)

    Verma, P.K.; Chandraker, D.K.; Nayak, A.K.; Vijayan, P.K.

    2015-01-01

    Large water pools are used as a heat sink for various cooling systems used in industry. In context of advance nuclear reactors like AHWR, it is used as ultimate heat sink for passive systems for decay heat removal and containment cooling. This system incorporates heat exchangers submerged in the large water pool. However, heat transfer by natural convection in pool poses a problem of thermal stratification. Due to thermal stratification hot layers of water accumulate over the relatively cold one. The heat transfer performance of heat exchanger gets deteriorated as a hot fluid envelops it. In the nuclear reactors, the walls of the pool are made of concrete and it may subject to high temperature due to thermal stratification which is not desirable. In this paper, a concept of employing shrouds around the heat source is studied. These shrouds provide a bulk flow in the water pool, thereby facilitating mixing of hot and cold fluid, which eliminate stratification. The concept has been applied to the a scaled model of Gravity Driven Water Pool (GDWP) of AHWR in which Isolation Condensers (IC) tubes are submerged for decay heat removal of AHWR using ICS and thermal stratification phenomenon was predicted with and without shrouds. To demonstrate the adequacy of the effectiveness of shroud arrangement and to validate the simulation methodology of RELAP5/Mod3.2, experiments has been conducted on a scaled model of the pool with and without shroud. (author)

  1. Spent fuel pool cleanup and stabilization

    International Nuclear Information System (INIS)

    Miller, R.L.

    1987-06-01

    Each of the plutonium production reactors at Hanford had a large water-filled spent fuel pool to provide interim storage of irradiated fuel while awaiting shipment to the separation facilities. After cessation of reactor operations the fuel was removed from the pools and the water levels were drawn down to a 5- to 10-foot depth. The pools were maintained with the water to provide shielding and radiological control. What appeared to be a straightforward project to process the water, remove the sediments from the basin, and stabilize the contamination on the floors and walls became a very complex and time consuming operation. The sediment characteristics varied from pool to pool, the ion exchange system required modification, areas of hard-pack sediments were discovered on the floors, special arrangements to handle and package high dose rate items for shipment were required, and contract problems ensued with the subcontractor. The original schedule to complete the project from preliminary engineering to final stabilization of the pools was 15 months. The actual time required was about 25 months. The original cost estimate to perform the work was $2,651,000. The actual cost of the project was $5,120,000, which included $150,000 for payment of claims to the subcontractor. This paper summarizes the experiences associated with the cleanup and radiological stabilization of the 100-B, -C, -D, and -DR spent fuel pools, and discusses a number of lessons learned items

  2. Fluid-structure interaction analysis of a water pool under loading caused by steam injection

    International Nuclear Information System (INIS)

    Timperi, A.; Paettikangas, T.; Niemi, J.; Ilvonen, M.

    2006-04-01

    CFD and structural analysis codes. MpCCI 3.0 was used for coupling Fluent CFD code with ABAQUS FE code. ES-FSI was used for coupling Star-CD CFD code with ABAQUS. FSI analyses, in which the calculation was carried out entirely in ABAQUS, were also performed. In this case, acoustic elements were used for the fluid and the acoustic and structural domains were coupled. FSI calculations were performed for simple test cases and for a test pool at Lappeenranta University of Technology. The Method of Images was studied as an alternative method for the analyses of the pool. Particularly, the determination of pressure source for the method was studied. Earlier work carried out with the homogenous two-phase model was continued by testing the model with Fluent. Calculation of condensation of steam in a water pool was tested with a new implementation. The two-directionally coupled simulations of the pool with MpCCI and ES-FSI were found to be numerically instable. It was concluded that an implicit coupling method may have to be used in order to avoid the instability. Calculations of the pool were finally performed by using one directional coupling. In the simulations with MpCCI, the incompressible and compressible VOF models of Fluent were used. With ES-FSI, the incompressible VOF model of Star-CD was used for modelling the beginning of a steam injection experiment. The magnitudes of pressure and stress peaks in the simulation and experiment were of comparable size. Otherwise, however, differences between the simulation and experiment were large due to the simplifications used in the simulation. Results obtained with the acoustic-structural FE analyses were compared to analytical and experimental results. The results indicated that the coupled acoustic-structural analysis can be used for calculating the coupled Eigenmodes of BWR pressure suppression pools. (au)

  3. Fluid-structure interaction analysis of a water pool under loading caused by steam injection

    Energy Technology Data Exchange (ETDEWEB)

    Timperi, A.; Paettikangas, T.; Niemi, J.; Ilvonen, M. [VTT Technical Researc Centre of Finland (Finland)

    2006-04-15

    CFD and structural analysis codes. MpCCI 3.0 was used for coupling Fluent CFD code with ABAQUS FE code. ES-FSI was used for coupling Star-CD CFD code with ABAQUS. FSI analyses, in which the calculation was carried out entirely in ABAQUS, were also performed. In this case, acoustic elements were used for the fluid and the acoustic and structural domains were coupled. FSI calculations were performed for simple test cases and for a test pool at Lappeenranta University of Technology. The Method of Images was studied as an alternative method for the analyses of the pool. Particularly, the determination of pressure source for the method was studied. Earlier work carried out with the homogenous two-phase model was continued by testing the model with Fluent. Calculation of condensation of steam in a water pool was tested with a new implementation. The two-directionally coupled simulations of the pool with MpCCI and ES-FSI were found to be numerically instable. It was concluded that an implicit coupling method may have to be used in order to avoid the instability. Calculations of the pool were finally performed by using one directional coupling. In the simulations with MpCCI, the incompressible and compressible VOF models of Fluent were used. With ES-FSI, the incompressible VOF model of Star-CD was used for modelling the beginning of a steam injection experiment. The magnitudes of pressure and stress peaks in the simulation and experiment were of comparable size. Otherwise, however, differences between the simulation and experiment were large due to the simplifications used in the simulation. Results obtained with the acoustic-structural FE analyses were compared to analytical and experimental results. The results indicated that the coupled acoustic-structural analysis can be used for calculating the coupled Eigenmodes of BWR pressure suppression pools. (au)

  4. Distributed Technologies in a Data Pool

    Science.gov (United States)

    Keiser, K.; Conover, H.; Graves, S.; He, Y.; Regner, K.; Smith, M.

    2004-12-01

    A Data Pool is an on-line repository providing interactive and programmatic access to data products through a variety of services. The University of Alabama in Huntsville has developed and deployed such a Data Pool in conjunction with the DISCOVER project, a collaboration with NASA and Remote Sensing Systems. DISCOVER provides long-term ocean and climate data from a variety of passive microwave satellite instruments, including such products as sea-surface temperature and wind, air temperature, atmospheric water vapor, cloud water and rain rate. The Data Pool provides multiple methods to access and visualize these products, including conventional HTTP and FTP access, as well as data services that provide for enhanced usability and interoperability, such as GridFTP, OPeNDAP, OpenGIS-compliant web mapping and coverage services, and custom subsetting and packaging services. This paper will focus on the distributed service technologies used in the Data Pool, which spans heterogeneous machines at multiple locations. For example, in order to provide seamless access to data at multiple sites, the Data Pool provides catalog services for all data products at the various data server locations. Under development is an automated metadata generation tool that crawls the online data repositories regularly to dynamically update the Data Pool catalog with information about newly generated data files. For efficient handling of data orders across distributed repositories, the Data Pool also implements distributed data processing services on the file servers where the data resides. Ontologies are planned to support automated service chaining for custom user requests. The UAH Data Pool is based on a configurable technology framework that integrates distributed data services with a web interface and a set of centralized database services for catalogs and order tracking. While this instantiation of the Data Pool was implemented to meet the needs of the DISCOVER project, the framework was

  5. A Pool of Distant Galaxies

    Science.gov (United States)

    2008-11-01

    Anyone who has wondered what it might be like to dive into a pool of millions of distant galaxies of different shapes and colours, will enjoy the latest image released by ESO. Obtained in part with the Very Large Telescope, the image is the deepest ground-based U-band image of the Universe ever obtained. It contains more than 27 million pixels and is the result of 55 hours of observations with the VIMOS instrument. A Sea of Galaxies ESO PR Photo 39/08 A Pool of Distant Galaxies This uniquely beautiful patchwork image, with its myriad of brightly coloured galaxies, shows the Chandra Deep Field South (CDF-S), arguably the most observed and best studied region in the entire sky. The CDF-S is one of the two regions selected as part of the Great Observatories Origins Deep Survey (GOODS), an effort of the worldwide astronomical community that unites the deepest observations from ground- and space-based facilities at all wavelengths from X-ray to radio. Its primary purpose is to provide astronomers with the most sensitive census of the distant Universe to assist in their study of the formation and evolution of galaxies. The new image released by ESO combines data obtained with the VIMOS instrument in the U- and R-bands, as well as data obtained in the B-band with the Wide-Field Imager (WFI) attached to the 2.2 m MPG/ESO telescope at La Silla, in the framework of the GABODS survey. The newly released U-band image - the result of 40 hours of staring at the same region of the sky and just made ready by the GOODS team - is the deepest image ever taken from the ground in this wavelength domain. At these depths, the sky is almost completely covered by galaxies, each one, like our own galaxy, the Milky Way, home of hundreds of billions of stars. Galaxies were detected that are a billion times fainter than the unaided eye can see and over a range of colours not directly observable by the eye. This deep image has been essential to the discovery of a large number of new galaxies

  6. Modal analysis of pool door in water tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Soo; Jeong, Kyeong Hoon; Park, Chan Gook; Koo, In Soo [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    A pool door is installed at the chase of the pool gate by means of an overhead crane in the building of a research reactor. The principal function of the pool door, which is located between the reactor pool and service pool, is to separate the reactor pool from the service pool for the maintenance and/or the removal of the equipment either in the reactor pool or service pool. The pool door consists of stainless steel plates supported by structural steel frames and sealing components. The pool door is equipped with double inflatable gaskets. The configuration of the pool door is shown in Figure 1. The FEM analysis and theoretical calculation by the formula were performed to evaluate the natural frequency for the pool door in the water. The results from the two methods were compared.

  7. The Role of Nuclear Insurance Pools

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2006-01-01

    Since fifty years insurers respond to the need of both governments and the electricity industry to provide financial protection to cover the perils presented by the use of nuclear energy for peaceful purposes. This paper aims at explaining what difficulties had to be solved in order to enable insurers to provide such protection, that as a solution to these difficulties Nuclear Insurance Pools were formed, how such pools operate and what security they provide. Thereby not only a number of universal principles underlying nuclear pool insurance will be explained, but also some differences in the characteristics of such insurance per group of countries. (author)

  8. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  9. 10 CFR 36.63 - Pool water purity.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Pool water purity. 36.63 Section 36.63 Energy NUCLEAR... § 36.63 Pool water purity. (a) Pool water purification system must be run sufficiently to maintain the conductivity of the pool water below 20 microsiemens per centimeter under normal circumstances. If pool water...

  10. Parametric tomography of the cardiac blood pool

    International Nuclear Information System (INIS)

    Meyer, M.; Schwartz, K.D.

    1990-01-01

    In nuclear cardiology image processing is performed usually in 3 of 4 dimensions. ECG-gated SPECT (GSPECT) would make it possible to obtain all 4 dimensions of space and time during one examination, but its duration as well as radiation dose is limited resulting in a low signal-to-noise ratio. Sensitive feature extractions from the amount of data are necessary, e.g. Fourier filtering or extracting isovolumetric intervals. The relatively large amount of calculations and storage requirements often handicaps tomographic ventriculography because a high number of sections have to be processed and the temporal resolution is limited. A new list-mode oriented tomographic algorithm demands less storage and fewer calculations: The Fourier coefficient extraction and the filtered back projection, both of which are linear operations, could be interchanged in the case of thoracic SPECT. The feature extraction algorithm process internal list-mode heart cycles for discrimination of invalid cycles, for end-diastolic and end-systolic synthesis as well as for Fourier analysis of the first harmonic in 10 ms steps. Reconstruction operations are applied also to modified distribution matrices of Fourier coefficients. By only processing 4 spatial matrix sequences (end-diastolic and end-systolic images, amplitude and phase values) parametric tomography becomes practicable and could be also performed by a minicomputer with 64 KByte memory in addition to the possibilities of the planar left ventricular gated imaging. If there are 3 or more processors available a complete feature extraction on-the-fly will be possible. The numerical algorithms were tested with respect to stable reconstructions by phantoms. First results of a patient examination are used to explore effective display techniques, and preliminary modes are demonstrated. It is the purpose of this study to obtain additional information about the gated planar cardiac blood pool imaging in the field of SPECT. (author)

  11. The Nuclear Insurance Pools: Operations and Covers

    International Nuclear Information System (INIS)

    Tetley, M.

    2008-01-01

    Nuclear insurance pools have provided insurance for the nuclear industry for over fifty years and it is fair to say that the development of civil nuclear power would not have been possible without the support of the commercial insurance market. The unknown risks presented by the nascent nuclear power industry in the 1950s required a leap of faith by insurers who developed specialist pooled insurance capacity to ensure adequate capacity to back up the operators' compensation obligations. Since then, nuclear insurance pools have evolved to become comprehensive suppliers of most types of insurance for nuclear plant globally. This paper will outline the structure, development, products and current operations of nuclear insurance pools.(author)

  12. Ingestion of swimming pool water by recreational

    Data.gov (United States)

    U.S. Environmental Protection Agency — Swimming pool water ingestion data. This dataset is associated with the following publication: Dufour, A., L. Wymer, M. Magnuson, T. Behymer, and R. Cantu. Ingestion...

  13. AE/VCE Unconfirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  14. AE/VCE Confirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  15. Investigations in Marine Chemistry: Tide Pool Ecology.

    Science.gov (United States)

    Schlenker, Richard M.

    Students investigated the salinity of tide pools at different levels in the intertidal zone. Data are analyzed collectively. Students graphed and discussed data. Included are suggestions for evaluation and further study. (Author)

  16. 7 CFR 1126.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the plant's shipping percentage. (d) A plant... part, or the plant has automatic pooling status under the other Federal order; and (7) That portion of...

  17. 7 CFR 1001.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the percentages in paragraphs (c)(1) and (2) of... plant has automatic pooling status under the other Federal order. [64 FR 47954, Sept. 1, 1999, as...

  18. 7 CFR 1007.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ...-upon use other than Class I shall be excluded from the supply plant's shipments in computing the plant... under the order in this part, or such plant has automatic pooling status under such other order. (h) Any...

  19. Microbial quality of a marine tidal pool

    CSIR Research Space (South Africa)

    Genthe, Bettina

    1995-01-01

    Full Text Available In this study the source of microbial pollution to a tidal pool was investigated. Both adjacent seawater which could contribute to possible faecal pollution and potential direct bather pollution were studied. The microbial quality of the marine...

  20. Robotic cleaning of a spent fuel pool

    International Nuclear Information System (INIS)

    Roman, H.T.; Marian, F.A.; Silverman, E.B.; Barkley, V.P.

    1987-01-01

    Spent fuel pools at nuclear power plants are not cleaned routinely, other than by purifying the water that they contain. Yet, debris can collect on the bottom of a pool and should be removed prior to fuel transfer. At Public Service Electric and Gas Company's Hope Creek Nuclear Power Plant, a submersible mobile robot - ARD Corporation's SCAVENGER - was used to clean the bottom of the spent fuel pool prior to initial fuel loading. The robotic device was operated remotely (as opposed to autonomously) with a simple forward/reverse control, and it cleaned 70-80% of the pool bottom. This paper reports that a simple cost-benefit analysis shows that the robotic device would be less expensive, on a per mission basis, than other cleaning alternatives, especially if it were used for other similar cleaning operations throughout the plant

  1. Pooling strategies for St Petersburg gamblers

    OpenAIRE

    Csörgö, Sandor; Simons, Gordon

    2006-01-01

    Peter offers to play exactly one St Petersburg game with each of [math] players, Paul [math] , [math] , Paul [math] , whose conceivable pooling strategies are described by all possible probability distributions [math] . Comparing infinite expectations, we characterize among all [math] those admissible strategies for which the pooled winnings, each distributed as [math] , yield a finite added value for each and every one of Paul [math] , [math] , Paul [math] in comparison with their individual...

  2. Welding pool measurement using thermal array sensor

    Science.gov (United States)

    Cho, Chia-Hung; Hsieh, Yi-Chen; Chen, Hsin-Yi

    2015-08-01

    Selective laser melting (SLM) is an additive manufacturing (AM) technology that uses a high-power laser beam to melt metal powder in chamber of inert gas. The process starts by slicing the 3D CAD data as a digital information source into layers to create a 2D image of each layer. Melting pool was formed by using laser irradiation on metal powders which then solidified to consolidated structure. In a selective laser melting process, the variation of melt pool affects the yield of a printed three-dimensional product. For three dimensional parts, the border conditions of the conductive heat transport have a very large influence on the melt pool dimensions. Therefore, melting pool is an important behavior that affects the final quality of the 3D object. To meet the temperature and geometry of the melting pool for monitoring in additive manufacturing technology. In this paper, we proposed the temperature sensing system which is composed of infrared photodiode, high speed camera, band-pass filter, dichroic beam splitter and focus lens. Since the infrared photodiode and high speed camera look at the process through the 2D galvanometer scanner and f-theta lens, the temperature sensing system can be used to observe the melting pool at any time, regardless of the movement of the laser spot. In order to obtain a wide temperature detecting range, 500 °C to 2500 °C, the radiation from the melting pool to be measured is filtered into a plurality of radiation portions, and since the intensity ratio distribution of the radiation portions is calculated by using black-body radiation. The experimental result shows that the system is suitable for melting pool to measure temperature.

  3. Gravity and Heater Size Effects on Pool Boiling Heat Transfer

    Science.gov (United States)

    Kim, Jungho; Raj, Rishi

    2014-01-01

    The current work is based on observations of boiling heat transfer over a continuous range of gravity levels between 0g to 1.8g and varying heater sizes with a fluorinert as the test liquid (FC-72/n-perfluorohexane). Variable gravity pool boiling heat transfer measurements over a wide range of gravity levels were made during parabolic flight campaigns as well as onboard the International Space Station. For large heaters and-or higher gravity conditions, buoyancy dominated boiling and heat transfer results were heater size independent. The power law coefficient for gravity in the heat transfer equation was found to be a function of wall temperature under these conditions. Under low gravity conditions and-or for smaller heaters, surface tension forces dominated and heat transfer results were heater size dependent. A pool boiling regime map differentiating buoyancy and surface tension dominated regimes was developed along with a unified framework that allowed for scaling of pool boiling over a wide range of gravity levels and heater sizes. The scaling laws developed in this study are expected to allow performance quantification of phase change based technologies under variable gravity environments eventually leading to their implementation in space based applications.

  4. Pump/heat exchanger assembly for pool-type reactor

    International Nuclear Information System (INIS)

    Nathenson, R.D.; Slepian, R.M.

    1989-01-01

    This patent describes a heat exchanger and pump assembly for transferring thermal energy from a heated, first electrically conductive fluid to a pumped, second electrically conductive fluid and for transferring internal energy from the pumped, second electrically conductive fluid to the first electrically conductive fluid, the assembly adapted to be disposed within a pool of the first electrically conductive fluid and comprising: a heat exchanger comprising means for defining a first annularly shaped cavity for receiving a flow of the second electrically conductive fluid and a plurality of tubes disposed within the cavity, whereby the second electrically conductive fluid in the cavity is heated, each of the tubes having an input and an output end. The input ends being disposed at the top of the heat exchanger for receiving from the pool a flow of the first electrically conductive fluid therein. The output ends being disposed at the bottom of and free of the cavity defining means for discharging the first electrically conductive fluid directly into the pool; a pump disposed beneath the heat exchanger and comprised of a plurality of flow couplers disposed in a circular array, each flow coupler comprised of a pump duct for receiving the first electrically conductive fluid and a generator duct for receiving the second electrically conductive fluid

  5. Numerical modelling of methanol liquid pool fires

    Science.gov (United States)

    Prasad, Kuldeep; Li, Chiping; Kailasanath, K.; Ndubizu, Chuka; Ananth, Ramagopal; Tatem, P. A.

    1999-12-01

    The focus of this paper is on numerical modelling of methanol liquid pool fires. A mathematical model is first developed to describe the evaporation and burning of a two-dimensional or axisymmetric pool containing pure liquid methanol. Then, the complete set of unsteady, compressible Navier-Stokes equations for reactive flows are solved in the gas phase to describe the convection of the fuel gases away from the pool surface, diffusion of the gases into the surrounding air and the oxidation of the fuel into product species. Heat transfer into the liquid pool and the metal container through conduction, convection and radiation are modelled by solving a modified form of the energy equation. Clausius-Clapeyron relationships are invoked to model the evaporation rate of a two-dimensional pool of pure liquid methanol. The governing equations along with appropriate boundary and interface conditions are solved using the flux-corrected transport algorithm. Numerical results exhibit a flame structure that compares well with experimental observations. Temperature profiles and burning rates were found to compare favourably with experimental data from single- and three-compartment laboratory burners. The model predicts a puffing frequency of approximately 12 Hz for a 1 cm diameter methanol pool in the absence of any air co-flow. It is also observed that increasing the air co-flow velocity helps in stabilizing the diffusion flame, by pushing the vortical structures away from the flame region.

  6. Recent advances in probabilistic species pool delineations

    Directory of Open Access Journals (Sweden)

    Dirk Nikolaus Karger

    2016-07-01

    Full Text Available A species pool is the set of species that could potentially colonize and establish within a community. It has been a commonly used concept in biogeography since the early days of MacArthur and Wilson’s work on Island Biogeography. Despite their simple and appealing definition, an operational application of species pools is bundled with a multitude of problems, which have often resulted in arbitrary decisions and workarounds when defining species pools. Two recently published papers address the operational problems of species pool delineations, and show ways of delineating them in a probabilistic fashion. In both papers, species pools were delineated using a process-based, mechanistical approach, which opens the door for a multitude of new applications in biogeography. Such applications include detecting the hidden signature of biotic interactions, disentangling the geographical structure of community assembly processes, and incorporating a temporal extent into species pools. Although similar in their conclusions, both ‘probabilistic approaches’ differ in their implementation and definitions. Here I give a brief overview of the differences and similarities of both approaches, and identify the challenges and advantages in their application.

  7. Thermal hydraulic phenomena in corium pools: the BALI experiment

    International Nuclear Information System (INIS)

    Bonnet, J.M.

    1999-01-01

    In the framework of severe accident studies, the BALI experiment has been designed to create a data base about heat transfer distribution at corium pool boundaries for in-vessel or ex-vessel configurations. The mechanism investigated is natural convection at high internal Rayleigh number (10 15 to 10 17 ) in cavities with volumetric heating. After a description of the facility and a synthesis of results obtained for in-vessel configurations, the purpose of this paper is to present or extend local or average heat transfer correlations in the prototypic range of dimensionless parameters. (author)

  8. Energy Pooling Upconversion in Free Space and Optical Cavities

    Science.gov (United States)

    LaCount, Michael D.

    energy pooling rate efficiency of 99%. This demonstrates that the energy pooling rate can be made faster than its competing processes. Based on the results of this study, a set of design rules was developed to optimize the rate efficiency of energy pooling. Prior to this research, no attempt had been made to determine if energy pooling could be made to out-pace competing processes--i.e. whether or not a molecular system could be designed to utilize energy pooling as an efficient means of upconversion. This initial investigation was part of a larger effort involving a team of researchers at the University of Colorado, Boulder and at the National Renewable Energy Laboratory. After establishing our computational proof-of-concept, we collectively used the new design rules to select an improved system for energy pooling. This consisted of rhodamine 6G and stilbene-420. These molecules were fabricated into a thin film, and the maximum internal quantum yield was measured to be 36% under sufficiently high intensity light. To further increase the efficiency of energy pooling, encapsulation within optical cavities was considered as a way of changing the rate of processes characterized by electric dipole-dipole coupling. This was carried out using a combination of classical electromagnetism, quantum electrodynamics, and perturbation theory. It was found that, in the near field, if the distance of the energy transfer is smaller than the distance from the energy transfer site and the cavity wall, then the electric dipole-dipole coupling tensor is not influenced by the cavity environment and the rates of energy transfer processes are the same as those in free space. Any increase in energy transfer efficiencies that are experimentally measured must therefore be caused by changing the rate of light absorption and emission. This is an important finding because earlier, less rigorous studies had concluded otherwise. It has been previously demonstrated that an optical cavity can be used to

  9. Tunable molten oxide pool assisted plasma-melter vitrification systems

    Science.gov (United States)

    Titus, Charles H.; Cohn, Daniel R.; Surma, Jeffrey E.

    1998-01-01

    The present invention provides tunable waste conversion systems and apparatus which have the advantage of highly robust operation and which provide complete or substantially complete conversion of a wide range of waste streams into useful gas and a stable, nonleachable solid product at a single location with greatly reduced air pollution to meet air quality standards. The systems provide the capability for highly efficient conversion of waste into high quality combustible gas and for high efficiency conversion of the gas into electricity by utilizing a high efficiency gas turbine or an internal combustion engine. The solid product can be suitable for various commercial applications. Alternatively, the solid product stream, which is a safe, stable material, may be disposed of without special considerations as hazardous material. In the preferred embodiment, the arc plasma furnace and joule heated melter are formed as a fully integrated unit with a common melt pool having circuit arrangements for the simultaneous independently controllable operation of both the arc plasma and the joule heated portions of the unit without interference with one another. The preferred configuration of this embodiment of the invention utilizes two arc plasma electrodes with an elongated chamber for the molten pool such that the molten pool is capable of providing conducting paths between electrodes. The apparatus may additionally be employed with reduced use or without further use of the gases generated by the conversion process. The apparatus may be employed as a net energy or net electricity producing unit where use of an auxiliary fuel provides the required level of electricity production. Methods and apparatus for converting metals, non-glass forming waste streams and low-ash producing inorganics into a useful gas are also provided. The methods and apparatus for such conversion include the use of a molten oxide pool having predetermined electrical, thermal and physical

  10. Self-formed waterfall plunge pools in homogeneous rock

    Science.gov (United States)

    Scheingross, Joel S.; Lo, Daniel Y.; Lamb, Michael P.

    2017-01-01

    Waterfalls are ubiquitous, and their upstream propagation can set the pace of landscape evolution, yet no experimental studies have examined waterfall plunge pool erosion in homogeneous rock. We performed laboratory experiments, using synthetic foam as a bedrock simulant, to produce self-formed waterfall plunge pools via particle impact abrasion. Plunge pool vertical incision exceeded lateral erosion by approximately tenfold until pools deepened to the point that the supplied sediment could not be evacuated and deposition armored the pool bedrock floor. Lateral erosion of plunge pool sidewalls continued after sediment deposition, but primarily at the downstream pool wall, which might lead to undermining of the plunge pool lip, sediment evacuation, and continued vertical pool floor incision in natural streams. Undercutting of the upstream pool wall was absent, and our results suggest that vertical drilling of successive plunge pools is a more efficient waterfall retreat mechanism than the classic model of headwall undercutting and collapse in homogeneous rock.

  11. Structure of pool in reactor building

    International Nuclear Information System (INIS)

    Yokoyama, Shigeki.

    1997-01-01

    Shielding walls made of iron-reinforced concrete having a metal liner including two body walls rigidly combined to the upper surface of a reactor container are disposed at least to one of an equipment pool or spent fuel storage pool in a reactor building. A rack for temporarily placing an upper lattice plate is detachably attached at least above one of a steam dryer or a gas/liquid separator temporarily placed in the temporary pool, and the height from the bottom portion to the upper end of the shielding wall is determined based on the height of an upper lattice plate temporary placed on the rack and the water depth required for shielding radiation from the upper lattice plate. An operator's exposure on the operation floor can be reduced by the shielding wall, and radiation dose from the spent fuels is reduced. The increase of the height of a pool guarder enhances bending resistance as a ceiling. In addition, the total height of them is made identical with the depth of the spent fuel storage pool thereby enabling to increase storage area for spent fuels. (N.H.)

  12. Cooling device for reactor suppression pool

    International Nuclear Information System (INIS)

    Togasaki, Susumu; Kato, Kiyoshi.

    1994-01-01

    In a cooling device of a reactor suppression pool, when a temperature of pool water is abnormally increased and a heat absorbing portion is heated by, for example, occurrence of an accident, coolants are sent to the outside of the reactor container to actuates a thermally operating portion by the heat energy of coolants and drive heat exchanging fluids of a secondary cooling system. If the heat exchanging fluids are sent to a cooling portion, the coolants are cooled and returned to the heat absorbing portion of the suppression pool water. If the heat absorbing portion is heat pipes, the coolants are evaporated by heat absorbed from the suppression pool water, steams are sent to the thermally operating portion, then coolants are liquefied and caused to return to the heat absorbing portion. If the thermal operation portion is a gas turbine, the gas turbine is operated by the coolants, and it is converted to a rotational force to drive heat exchanging fluids by pumps. By constituting the cooling portion with a condensator, the coolants are condensed and liquefied and returned to the heat absorbing portion of the suppression pool water. (N.H.)

  13. Condensation in a two-phase pool

    International Nuclear Information System (INIS)

    Duffey, R.B.; Hughes, E.D.

    1991-01-01

    We consider the case of vapor condensation in a liquid pool, when the heat transfer is controlled by heat losses through the walls. The analysis is based on drift flux theory for phase separation in the pool, and determines the two-phase mixture height for the pool. To our knowledge this is the first analytical treatment of this classic problem that gives an explicit result, previous work having established the result for the evaporative case. From conservation of mass and energy in a one-dimensional steady flow, together with a void relation between the liquid and vapor fluxes, we determine the increase in the mixture level from the base level of the pool. It can be seen that the thermal and hydrodynamic influences are separable. Thus, the thermal influence of the wall heat transfer appears through its effect on the condensing length L*, so that at high condensation rates the pool is all liquid, and at low rates overflows (the level swell or foaming effect). Similarly, the phase separation effect hydrodynamically determines the height via the relative velocity of the mixture to the entering flux. We examine some practical applications of this result to level swell in condensing flows, and also examine some limits in ideal cases

  14. Heat and fission product transport in molten core material pool with crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2005-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the reactor vessel during a severe accident. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool is estimated by product of the mass concentration and energy conversion factor of each fission product. Twenty-nine elements are chosen and classified by their chemical properties to calculate heat generation rate in the pool. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis is performed for heat and fission product transport in a molten core material pool during the Three Mile Island Unit 2 (TMI-2) accident. The pool is assumed to be a partially filled hemisphere, whose change in geometry is neglected during the numerical calculation. Calculated results indicate that the peak temperature in the molten pool is significantly lowered, since a substantial amount of the volatile fission products is released from the molten pool during progression of the accident. The results may directly be applied to the existing severe accident analysis codes to more mechanistically determine the thermal load to the reactor vessel lower head during the in-vessel retention

  15. Effects of Pedogenic Fe Oxides on Soil Aggregate-Associated Carbon

    Science.gov (United States)

    Asefaw Berhe, A.; Jin, L.

    2017-12-01

    Carbon sequestration is intimately related to the soil structure, mainly soil aggregate dynamics. Carbon storage in soil aggregates has been recognized as an important carbon stabilization mechanism in soils. Organic matter and pedogenic Fe oxides are major binding agents that facilitate soil aggregate formation and stability. However, few studies have investigated how different forms of pedogenic Fe oxides can affect soil carbon distribution in different aggregate-size fractions. We investigated sequentially extracted pedogenic Fe oxides (in the order of organically complexed Fe extracted with sodium pyrophosphate, poorly-crystalline Fe oxides extracted with hydroxylamine hydrochloride, and crystalline Fe oxides extracted with dithionite hydrochloride) and determined the amount and nature of C in macroaggregates (2-0.25mm), microaggregates (0.25-0.053mm), and two silt and clay fractions (0.053-0.02mm, and soil from Sierra Nevada mountain in California. We also determined how pedogenic Fe oxides affect soil carbon distribution along soil depth gradients. Findings of our study revealed that the proportion of organic matter complexed Fe decreased, but the proportion of crystalline Fe increased with increasing soil depths. Poorly crystalline Fe oxides (e.g. ferrihydrite) was identified as a major Fe oxide in surface soil, whereas crystalline Fe oxides (e.g. goethite) were found in deeper soil layers. These results suggest that high concentration of organic matter in surface soil suppressed Fe crystallization. Calcium cation was closely related to the pyrophosphate extractable Fe and C, which indicates that calcium may be a major cation that contribute to the organic matter complexed Fe and C pool. Increasing concentrations of extractable Fe and C with decreasing aggregate size fractions also suggests that Fe oxides play an important role in formation and stability of silt and clay fractions, and leading to further stabilization of carbon in soil. Our findings provide

  16. 13 CFR 120.1706 - Pool Originator's retained interest in Pool.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pool Originator's retained interest in Pool. 120.1706 Section 120.1706 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan...

  17. Strategies for chemically healthy public swimming pools

    DEFF Research Database (Denmark)

    Hansen, Kamilla Marie Speht

    spreading of pathogens between swimmers because of its residual disinfection effect. In addition to potential contamination of pathogenic microorganisms, swimming pool water is polluted by organic matter deposited from the bathers such as saliva, urine, sweat, hair and personal care products. Since chlorine...... is a strong oxidant it oxidizes the organic matter in the pool water and forms disinfection byproducts (DBPs). More than 100 different DBPs have been identified. Some of these have been found to be genotoxic and may pose an increased cancer risk for the bathers. The aim of this thesis was to give an overview...... of the strategies which can be used to achieve microbiological safe water with low levels of DBPs to ensure healthy environment for bathers. There are different approaches to achieve healthy environment in public swimming pools which in this thesis are divided into three strategies: alternatives to chlorination...

  18. Simulation of pool scrubbing experiments using BUSCA

    International Nuclear Information System (INIS)

    Dehbi, A.; Guentay, S.

    1994-01-01

    BUSCA-PSI is a computer code which predicts the aerosol scrubbing taking place when gas bubbles containing fission products rise through stagnant pools of water after a postulated severe accident. A Lagrangian formulation is adopted to follow the path of a bubble as it rises toward the surface of the pool. The BUSCA model includes most aerosol removal mechanisms which are thought to be significant, namely: Jet Impaction at tile orifice, Convection/Diffusiophoresis during steam condensation, Thermophoresis, Sedimentation, Centrifugal Impaction during bubble rise, and Brownian Diffusion. The hydraulic modelling offers a variety of options for the initial globule volume, the stable bubble size, tile bubble rise velocity, and the bubble shape. The heat and mass transfer part of tile model uses correlations found in the relevant literature. BUSCA simulations were performed to determine the decontamination factor (DF) dependence on key aerosol and thermal hydraulic parameters. The decontamination factor increases with height, pool temperature subcooling, and steam content. The decontamination factor exhibits a parabolic dependence on the particle radius. At low particle sizes, the DF is high due to Brownian Diffusion which is the dominant removal mechanism. The DF hits a minimum and then increases with particle size as Centrifugal Impaction and Sedimentation become important. In separate calculations, BUSCA was used to the simulate the aerosol scrubbing experiments performed by EPRI. For cold pool tests, the predicted scrubbing efficiencies were in a good, conservative agreement with the data for both Tin and CsI, and the discrepancies were within the reported measurement errors. For hot pool tests, the code systematically underpredicted the scrubbing DF's; this is potentially due to condensation in the gas space above the pool, a situation not currently modelled by BUSCA. The code was also tested against data produced by the Tepco-Toshiba-Hitachi experiments. The

  19. Zooplankton at deep Red Sea brine pools

    KAUST Repository

    Kaartvedt, Stein

    2016-03-02

    The deep-sea anoxic brines of the Red Sea comprise unique, complex and extreme habitats. These environments are too harsh for metazoans, while the brine–seawater interface harbors dense microbial populations. We investigated the adjacent pelagic fauna at two brine pools using net tows, video records from a remotely operated vehicle and submerged echosounders. Waters just above the brine pool of Atlantis II Deep (2000 m depth) appeared depleted of macrofauna. In contrast, the fauna appeared to be enriched at the Kebrit Deep brine–seawater interface (1466 m).

  20. One component, volume heated, boiling pool thermohydraulics

    International Nuclear Information System (INIS)

    Bede, M.; Perret, C.; Pretrel, H.; Seiler, J.M.

    1993-01-01

    Prior work on boiling pools provided heat exchange correlations valid for bubbly flow with laminar or turbulent boundary layers. New experiments performed with water (SEBULON) and UO 2 (SCARABEE BF2) in a churn-turbulent flow configuration show unexpected heat flux distributions for which the maximum heat flux may be situated well below the pool surface. The origin of this behaviour is attributed to condensation effects, very unstable boundary layer flow and surface oscillation. A calculation model is discussed which permits to approach the experimental heat flux distribution with reasonable accuracy. (authors). 7 figs., 2 appendix., 14 refs

  1. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    International Nuclear Information System (INIS)

    Sathiah, Pratap; Roelofs, Ferry

    2014-01-01

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor

  2. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    Energy Technology Data Exchange (ETDEWEB)

    Sathiah, Pratap, E-mail: pratap.sathiah78@gmail.com [Shell Global Solutions Ltd., Brabazon House, Concord Business Park, Threapwood Road, Manchester M220RR (United Kingdom); Roelofs, Ferry, E-mail: roelofs@nrg.eu [Nuclear Research and Consultancy Group (NRG), Westerduinweg 3, 1755ZG Petten (Netherlands)

    2014-10-15

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor.

  3. 13 CFR 120.1705 - Pool formation requirements.

    Science.gov (United States)

    2010-01-01

    ... requirements. SBA may adjust the Pool characteristics periodically based on program experience and market... a Pool involving a Pool Loan it does not own, it must purchase the Loan Interest it proposes to pool... purchase the Loan Interest and take it into inventory or settle the purchase of the Loan Interest through...

  4. Delineating probabilistic species pools in ecology and biogeography

    OpenAIRE

    Karger, Dirk Nikolaus; Cord, Anna F; Kessler, Michael; Kreft, Holger; Kühn, Ingolf; Pompe, Sven; Sandel, Brody; Sarmento Cabral, Juliano; Smith, Adam B; Svenning, Jens-Christian; Tuomisto, Hanna; Weigelt, Patrick; Wesche, Karsten

    2016-01-01

    Aim To provide a mechanistic and probabilistic framework for defining the species pool based on species-specific probabilities of dispersal, environmental suitability and biotic interactions within a specific temporal extent, and to show how probabilistic species pools can help disentangle the geographical structure of different community assembly processes. Innovation Probabilistic species pools provide an improved species pool definition based on probabilities in conjuncti...

  5. A strategy for optimizing item-pool management

    NARCIS (Netherlands)

    Ariel, A.; van der Linden, Willem J.; Veldkamp, Bernard P.

    2006-01-01

    Item-pool management requires a balancing act between the input of new items into the pool and the output of tests assembled from it. A strategy for optimizing item-pool management is presented that is based on the idea of a periodic update of an optimal blueprint for the item pool to tune item

  6. Public Swimming Pools | Florida Department of Health

    Science.gov (United States)

    Illness Disease Reporting and Surveillance Bureau of Public Health Laboratories Environmental Health Air Air Monitoring Carbon Monoxide Indoor Air Quality Mold Radon Water Aquatic Toxins Beach Water Quality purification, testing, treatment, and disinfection procedures. To ensure that the pool technicians are

  7. 28 CFR 540.64 - Press pools.

    Science.gov (United States)

    2010-07-01

    ... Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT CONTACT WITH PERSONS IN THE COMMUNITY Contact With News Media § 540.64 Press pools. (a) The Warden may establish a... shall notify all news media representatives who have requested interviews or visits that have not been...

  8. Stein's neuronal model with pooled renewal input

    Czech Academy of Sciences Publication Activity Database

    Rajdl, K.; Lánský, Petr

    2015-01-01

    Roč. 109, č. 3 (2015), s. 389-399 ISSN 0340-1200 Institutional support: RVO:67985823 Keywords : Stein’s model * Poisson process * pooled renewal processes * first-passage time Subject RIV: BA - General Mathematics Impact factor: 1.611, year: 2015

  9. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  10. Swimming-pool piles; Piles piscines

    Energy Technology Data Exchange (ETDEWEB)

    Trioulaire, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10{sup 13}. This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [French] En France, deux piles piscines, Melusine et Triton, viennent d'entrer en service. La pile piscine est l'outil de recherche ideal pour des flux de neutrons de l'ordre de 10{sup 13}. Ce type de pile peut interesser des maintenant de nombreux centres de recherches mais il faut reduire son prix de revient et rompre avec le conformisme de sa conception. Il y a avantage: - a enterrer la piscine; - a supprimer les canaux experimentaux; - a concentrer le circuit de refrigeration dans la piscine; - a effectuer toutes les manipulations dans l'eau; - a doubler le coeur. (auteur)

  11. Spectrum pooling in MnWave Networks

    DEFF Research Database (Denmark)

    Boccardi, Federico; Shokri-Ghadikolaei, Hossein; Fodor, Gabor

    2016-01-01

    Motivated by the specific characteristics of mmWave technologies, we discuss the possibility of an authorization regime that allows spectrum sharing between multiple operators, also referred to as spectrum pooling. In particular, considering user rate as the performance measure, we assess...

  12. Pooling Objects for Recognizing Scenes without Examples

    NARCIS (Netherlands)

    Kordumova, S.; Mensink, T.; Snoek, C.G.M.

    2016-01-01

    In this paper we aim to recognize scenes in images without using any scene images as training data. Different from attribute based approaches, we do not carefully select the training classes to match the unseen scene classes. Instead, we propose a pooling over ten thousand of off-the-shelf object

  13. The new pooled cohort equations risk calculator

    DEFF Research Database (Denmark)

    Preiss, David; Kristensen, Søren L

    2015-01-01

    disease and any measure of social deprivation. An early criticism of the Pooled Cohort Equations Risk Calculator has been its alleged overestimation of ASCVD risk which, if confirmed in the general population, is likely to result in statin therapy being prescribed to many individuals at lower risk than...

  14. DNA pooling strategies for categorical (ordinal) traits

    Science.gov (United States)

    Despite reduced genotyping costs in recent years, obtaining genotypes for all individuals in a population may still not be feasible when sample size is large. DNA pooling provides a useful alternative to determining genotype effects. Clustering algorithms allow for grouping of individuals (observati...

  15. Pooling ASR data for closely related languages

    CSIR Research Space (South Africa)

    Van Heerden, C

    2010-05-01

    Full Text Available We describe several experiments that were conducted to assess the viability of data pooling as a means to improve speech-recognition performance for under-resourced languages. Two groups of closely related languages from the Southern Bantu language...

  16. "Teisele poole" Agambeniga ja Agambenita / Ragne Nukk

    Index Scriptorium Estoniae

    Nukk, Ragne, 1984-

    2012-01-01

    Tallinna Fotokuu rahvusvahelise fotonäituse "Teisele poole" ideeliste lähtekohtade tõlgendamisest. Autor kõrvutab Adam Budaki kuraatornäituse aluseks olnud Giorgio Agambeni esseed „Viimne kohtupäev“ näitusel eksponeeritud piltidega

  17. 7 CFR 1033.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... association and it fulfills the following conditions: (1) The aggregate monthly quantity supplied by all... or aseptically-processed fluid milk products. (c) A supply plant from which the quantity of bulk... operator of a supply plant located within the marketing area may include deliveries to pool distributing...

  18. Effect of fire on Hg pools in soils of forested ecosystem

    Czech Academy of Sciences Publication Activity Database

    Navrátil, Tomáš; Hojdová, Maria; Rohovec, Jan; Penížek, V.; Vařilová, Z.

    2008-01-01

    Roč. 34, 4/6 (2008), s. 1340433-1340433 ISSN 0161-6951. [International Geological Congress /33./. 06.08.2008-14.08.2008, Oslo ] R&D Projects: GA ČR GP526/07/P170 Institutional research plan: CEZ:AV0Z30130516 Keywords : mercury * pools * forest soil * fire Subject RIV: DD - Geochemistry

  19. Electricity supply and demand scenarios for the Southern African power pool

    CSIR Research Space (South Africa)

    Spalding-Fecher, R

    2017-02-01

    Full Text Available The study presents long-term electricity supply and demand scenarios for the twelve countries in the Southern African Power Pool, based on detailed bottom-up demand analysis for all countries and a set of internally consistent development scenarios...

  20. Discussions on the Design of the Pool Landscape in the Rain Garden Construction

    Science.gov (United States)

    Zou, Shuzhen; Zhu, Yirong; Wei, Chaojun; Tao, Biaohong

    2018-03-01

    With rapid urbanization, the environmental problems are becoming increasingly prominent and diversified ecological landscape designs consequently appear with the rain garden landscape design as a typical. Based on the introduction to rain garden ecological functions and in combination with domestic and international rain garden landscape design cases, this paper discussed the rain garden pool landscape design.

  1. Benthic assemblages of rock pools in northern Portugal: seasonal and between-pool variability

    Directory of Open Access Journals (Sweden)

    Iacopo Bertocci

    2012-11-01

    Full Text Available We investigated the seasonal (winter vs summer and within season and spatial (between-pool variability of benthic assemblages of rock pools at mid-intertidal level along the shore of Viana do Castelo (North Portugal. Physical traits of rock pools, including size, depth and position along the shore, were also compared between pools. While pools did not differ for any of the examined physical traits, results indicated a clear seasonal difference in the structure of assemblages, including a total of 49 macroalgal and 13 animal taxa. This finding was driven by six taxa that are more abundant in winter (the reef-forming polychaete Sabellaria alveolata, the articulated coralline algae Corallina spp., the brown alga Bifurcaria bifurcata, the encrusting coralline alga Lithophyllum incrustans, the red alga Chondracanthus acicularis and the grazing snails Gibbula spp. and four algal taxa that are more abundant in summer (the invasive brown Sargassum muticum, the green Ulva spp., the kelp Laminaria ochroleuca and the filamentous red Ceramium spp.. These data provide a new contribution to the knowledge of rock pool systems and have potential implications for monitoring programmes aimed at assessing ecological modifications related to natural and anthropogenic disturbances and for identifying processes responsible for the variability of rock pool assemblages.

  2. Safety classification of systems, structures, and components for pool-type research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ryong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-08-15

    Structures, systems, and components (SSCs) important to safety of nuclear facilities shall be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions. Although SSC classification guidelines for nuclear power plants have been well established and applied, those for research reactors have been only recently established by the International Atomic Energy Agency (IAEA). Korea has operated a pool-type research reactor (the High Flux Advanced Neutron Application Reactor) and has recently exported another pool-type reactor (Jordan Research and Training Reactor), which is being built in Jordan. Korea also has a plan to build one more pool-type reactor, the Kijang Research Reactor, in Kijang, Busan. The safety classification of SSCs for pool-type research reactors is proposed in this paper based on the IAEA methodology. The proposal recommends that the SSCs of pool-type research reactors be categorized and classified on basis of their safety functions and safety significance. Because the SSCs in pool-type research reactors are not the pressure-retaining components, codes and standards for design of the SSCs following the safety classification can be selected in a graded approach.

  3. Spent fuel and fuel pool component integrity. Annual report, FY 1979

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.; Bailey, W.J.; Schreiber, R.E.; Kustas, F.M.

    1980-05-01

    International meetings under the BEFAST program and under INFCE Working Group No. 6 during 1978 and 1979 continue to indicate that no cases of fuel cladding degradation have developed on pool-stored fuel from water reactors. A section from a spent fuel rack stand, exposed for 1.5 y in the Yankee Rowe (PWR) pool had 0.001- to 0.003-in.-deep (25- to 75-μm) intergranular corrosion in weld heat-affected zones but no evidence of stress corrosion cracking. A section of a 304 stainless steel spent fuel storage rack exposed 6.67 y in the Point Beach reactor (PWR) spent fuel pool showed no significant corrosion. A section of 304 stainless steel 8-in.-dia pipe from the Three Mile Island No. 1 (PWR) spent fuel pool heat exchanger plumbing developed a through-wall crack. The crack was intergranular, initiating from the inside surface in a weld heat-affected zone. The zone where the crack occurred was severely sensitized during field welding. The Kraftwerk Union (Erlangen, GFR) disassembled a stainless-steel fuel-handling machine that operated for 12 y in a PWR (boric acid) spent fuel pool. There was no evidence of deterioration, and the fuel-handling machine was reassembled for further use. A spent fuel pool at a Swedish PWR was decontaminated. The procedure is outlined in this report

  4. Corium quench in deep pool mixing experiments

    International Nuclear Information System (INIS)

    Spencer, B.W.; McUmber, L.; Gregorash, D.; Aeschlimann, R.; Sienicki, J.J.

    1985-01-01

    The results of two recent corium-water thermal interaction (CWTI) tests are described in which a stream of molten corium was poured into a deep pool of water in order to determine the mixing behavior, the corium-to-water heat transfer rates, and the characteristic sizes of the quenched debris. The corium composition was 60% UO 2 , 16% ZrO 2 , and 24% stainless steel by weight; its initial temperature was 3080 K, approx.160 K above the oxide phase liquidus temperature. The corium pour stream was a single-phase 2.2 cm dia liquid column which entered the water pool in film boiling at approx.4 m/s. The water subcooling was 6 and 75C in the two tests. Test results showed that with low subcooling, rapid steam generation caused the pool to boil up into a high void fraction regime. In contrast, with large subcooling no net steam generation occurred, and the pool remained relatively quiescent. Breakup of the jet appeared to occur by surface stripping. In neither test was the breakup complete during transit through the 32 cm deep water pool, and molten corium channeled to the base where it formed a melt layer. The characteristic heat transfer rates measured 3.5 MJ/s and 2.7 MJ/s during the fall stage for small and large subcooling, respectively; during the initial stage of bed quench, the surface heat fluxes measured 2.4 MW/m 2 and 3.7 MW/m 2 , respectively. A small mass of particles was formed in each test, measuring typically 0.1 to 1 mm and 1 to 5 mm dia for the large and small subcooling conditions, respectively. 9 refs., 13 figs., 1 tab

  5. Suncatcher and cool pool. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, J.

    1981-03-01

    The Suncatcher is a simple, conical solar concentrating device that captures light entering clerestory windows and directs it onto thermal storage elements at the back of a south facing living space. The cone shape and inclination are designed to capture low angle winter sunlight and to reflect away higher angle summer sunlight. It is found that winter radiation through a Suncatcher window is 40 to 50% higher than through an ordinary window, and that the average solar fraction is 59%. Water-filled steal culvert pipes used for thermal storage are found to undergo less stratification, and thus to be more effective, when located where sunlight strikes the bottom rather than the top. Five Suncatcher buildings are described. Designs are considered for 32/sup 0/, 40/sup 0/ and 48/sup 0/ north latitude, and as the latitude increases, the inclination angle of the cone should be lowered. The Cool Pool is an evaporating, shaded roof pond which thermosiphons cool water into water-filled columns within a building. Preliminary experiments indicate that the best shade design has unimpeded north sky view, good ventilation, complete summer shading, a low architectural profile, and low cost attic vent lowers work. Another series of experiments established the satisfactory performance of the Cool Pool on a test building using four water-filled cylinders, two cylinders, and two cylinders connected to the Cool Pool through a heat exchanger. Although an unshaded pool cools better at night than a shaded one, daytime heat gain far offsets this advantage. A vinyl waterbag heat exchanger was developed for use with the Cool Pool. (LEW)

  6. Experimental study of aerosol reentrainment from flashing pool in ALPHA program

    International Nuclear Information System (INIS)

    Kudo, T.; Yamano, N.; Moriyama, K.; Maruyama, Y.; Sugimoto, J.

    1994-01-01

    Aerosol reentrainment experiments are being performed as a part of the ALPHA (Assessment of Loads and Performance of Containment in a Hypothetical Accident) program at JAERI (Japan Atomic Energy Research Institute). The major objective of the experiments is to quantify and characterize the reentrainment of the dissolved material from a flashing pool during the rapid depressurization of a reactor containment vessel. Two experiments were performed. In the experiments a water pool dissolving sodium sulfate as FP simulant was located in the model containment vessel and the containment breach area was simulated with an orifice with 24 mm diameter. This orifice was estimated to give the same order of depressurization rate as the case of BWR Mark 1 containment failure with most likely breach size. In the first experiment ARE001, a pool water of 800 kg dissolving 50 kg of sodium sulfate was employed. The model containment was depressurized from 1.5 MPa to 0.1 MPa in approximately 45 minutes. In the second experiment ARE002, the mass of the pool water was reduced to 400 kg dissolving 25 kg of sodium sulfate. The internal pressure of the containment was decreased from 1.3 MPa to 0.1 MPa in approximately 40 minutes. At the beginning of the depressurization the pool water was heated to the saturation temperature at the internal pressure of the containment. The entrained droplets were sampled during depressurization period. Sodium sulfate deposited in all parts of the test facility was collected and weighed after the experiments. Results of the experiments showed that very small fraction of the dissolved material (less than 0.03%) was reentrained although approximately, 20% of water was evaporated from the pool water. The reentrained mass predicted with the Kataoka-Ishii model was approximately 1/110 of the mass evaluated in the experiments. This may be due to multi-dimensional features of the pool geometry. (author)

  7. Magnetic viscosity and coercivity mechanisms in sintered and melt spun NdFeB

    International Nuclear Information System (INIS)

    Street, R.; Bingham, D.; Day, R.K.; Dunlop, J.B.

    1988-01-01

    Magnetic viscosity parameters kT/q(=Sv) of sintered and melt spun NdFeB vary with internal field. During initial magnetization of thermally demagnetized specimens signifiant viscosity occurs with melt spun NdFeB but is negligible with sintered NdFeB. Differences in mechanisms of magnetization account for this behaviour

  8. Short-term changes in respiratory biomarkers after swimming in a chlorinated pool.

    Science.gov (United States)

    Font-Ribera, Laia; Kogevinas, Manolis; Zock, Jan-Paul; Gómez, Federico P; Barreiro, Esther; Nieuwenhuijsen, Mark J; Fernandez, Pilar; Lourencetti, Carolina; Pérez-Olabarría, Maitane; Bustamante, Mariona; Marcos, Ricard; Grimalt, Joan O; Villanueva, Cristina M

    2010-11-01

    Swimming in chlorinated pools involves exposure to disinfection by-products (DBPs) and has been associated with impaired respiratory health. We evaluated short-term changes in several respiratory biomarkers to explore mechanisms of potential lung damage related to swimming pool exposure. We measured lung function and biomarkers of airway inflammation [fractional exhaled nitric oxide (FeNO), eight cytokines, and vascular endothelial growth factor (VEGF) in exhaled breath condensate], oxidative stress (8-isoprostane in exhaled breath condensate), and lung permeability [surfactant protein D (SP-D) and the Clara cell secretory protein (CC16) in serum] in 48 healthy nonsmoking adults before and after they swam for 40 min in a chlorinated indoor swimming pool. We measured trihalomethanes in exhaled breath as a marker of individual exposure to DBPs. Energy expenditure during swimming, atopy, and CC16 genotype (rs3741240) were also determined. Median serum CC16 levels increased from 6.01 to 6.21 microg/L (average increase, 3.3%; paired Wilcoxon test p = 0.03), regardless of atopic status and CC16 genotype. This increase was explained both by energy expenditure and different markers of DBP exposure in multivariate models. FeNO was unchanged overall but tended to decrease among atopics. We found no significant changes in lung function, SP-D, 8-isoprostane, eight cytokines, or VEGF. We detected a slight increase in serum CC16, a marker of lung epithelium permeability, in healthy adults after they swam in an indoor chlorinated pool. Exercise and DBP exposure explained this association, without involving inflammatory mechanisms. Further research is needed to confirm the results, establish the clinical relevance of short-term serum CC16 changes, and evaluate the long-term health impacts.

  9. Revisiting the iron pools in cucumber roots: identification and localization.

    Science.gov (United States)

    Kovács, Krisztina; Pechoušek, Jiří; Machala, Libor; Zbořil, Radek; Klencsár, Zoltán; Solti, Ádám; Tóth, Brigitta; Müller, Brigitta; Pham, Hong Diep; Kristóf, Zoltán; Fodor, Ferenc

    2016-07-01

    Fe deficiency responses in Strategy I causes a shift from the formation of partially removable hydrous ferric oxide on the root surface to the accumulation of Fe-citrate in the xylem. Iron may accumulate in various chemical forms during its uptake and assimilation in roots. The permanent and transient Fe microenvironments formed during these processes in cucumber which takes up Fe in a reduction based process (Strategy I) have been investigated. The identification of Fe microenvironments was carried out with (57)Fe Mössbauer spectroscopy and immunoblotting, whereas reductive washing and high-resolution microscopy was applied for the localization. In plants supplied with (57)Fe(III)-citrate, a transient presence of Fe-carboxylates in removable forms and the accumulation of partly removable, amorphous hydrous ferric oxide/hydroxyde have been identified in the apoplast and on the root surface, respectively. The latter may at least partly be the consequence of bacterial activity at the root surface. Ferritin accumulation did not occur at optimal Fe supply. Under Fe deficiency, highly soluble ferrous hexaaqua complex is transiently formed along with the accumulation of Fe-carboxylates, likely Fe-citrate. As (57)Fe-citrate is non-removable from the root samples of Fe deficient plants, the major site of accumulation is suggested to be the root xylem. Reductive washing results in another ferrous microenvironment remaining in the root apoplast, the Fe(II)-bipyridyl complex, which accounts for ~30 % of the total Fe content of the root samples treated for 10 min and rinsed with CaSO4 solution. When (57)Fe(III)-EDTA or (57)Fe(III)-EDDHA was applied as Fe-source higher soluble ferrous Fe accumulation was accompanied by a lower total Fe content, confirming that chelates are more efficient in maintaining soluble Fe in the medium while less stable natural complexes as Fe-citrate may perform better in Fe accumulation.

  10. Decommissioning of the pool reactor Thetis in Ghent, Belgium

    Energy Technology Data Exchange (ETDEWEB)

    Cortenbosch, Geert; Mommaert, Chantal [Bel V, Brussels (Belgium); Tierens, Hubert; Monsieurs, Myriam; Meierlaen, Isabelle; Strijckmans, Karel [Ghent Univ. (Belgium)

    2016-11-15

    The Thetis research pool reactor (with a nominal power of 150 kW) of the Ghent University was operational from 1967 till December 2003. The first phase of the decommissioning of the reactor, the removal of the spent fuel from the site, took place in 2010. The cumulative dose received was only 404 man . μSv. During the second phase, the transition period between the removal of the spent fuel in 2010 and the start of the decommissioning phase in March 2013, 3-monthly internal inspections and inspections by Bel V, were performed. The third and final decommissioning phase started on March 18, 2013. The total dose received between March 2013 and August 2013 was 1561 man . μSv. The declassification from a Class I installation to a Class II installation was possible by the end of 2015. The activated concrete in the reactor pool will remain under regulatory control until the activation levels are lower than the limits for free release.

  11. Horizontal above-rack pool storage

    International Nuclear Information System (INIS)

    Moscardini, R.L.

    1993-08-01

    This report describes a unique method for storing spent, six year out of core, fuel at a prototypical PWR nuclear power station. The study describes a conceptual design, with favorable structural, thermal and criticality technical evaluations. However, economic considerations and licensing risks are judged to be less favorable. The concept study prescribes a fuel over fuel arrangement in an existing Spent Fuel Pool (SFP) with full maintenance of ALARA principles. This concept study is specific to a prototypical pool design, but may easily be projected to other nuclear facilities with other SFP conditions. For the prototypical PWR, the conceptual fuel bridge design will store over 200 additional fuel assemblies without significant facility modifications and for an indefinite time period

  12. Sodium pool fire model for CONACS code

    International Nuclear Information System (INIS)

    Yung, S.C.

    1982-01-01

    The modeling of sodium pool fires constitutes an important ingredient in conducting LMFBR accident analysis. Such modeling capability has recently come under scrutiny at Westinghouse Hanford Company (WHC) within the context of developing CONACS, the Containment Analysis Code System. One of the efforts in the CONACS program is to model various combustion processes anticipated to occur during postulated accident paths. This effort includes the selection or modification of an existing model and development of a new model if it clearly contributes to the program purpose. As part of this effort, a new sodium pool fire model has been developed that is directed at removing some of the deficiencies in the existing models, such as SOFIRE-II and FEUNA

  13. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  14. Review and assessment of pool scrubbing models

    International Nuclear Information System (INIS)

    Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez-Jimenez, J.

    1996-01-01

    Decontamination of fission products bearing bubbles as they through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC andBUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B.As a result of this work, model capabilities and shortcomings have beenassessed and some areas susceptible of further research have been identified.(Author) 73 refs

  15. Review and assessment of pool scrubbing models

    International Nuclear Information System (INIS)

    Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez, J.

    1996-01-01

    Decontamination of fission products bearing bubbles as they pass through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC and BUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B. As a result of this work, model capabilities and shortcomings have been assessed and some areas susceptible of further research have been identified. (Author) 73 refs

  16. Review and assessment of pool scrubbing models

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez, J.

    1996-07-01

    Decontamination of fission products bearing bubbles as they pass through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC and BUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B. As a result of this work, model capabilities and shortcomings have been assessed and some areas susceptible of further research have been identified. (Author) 73 refs.

  17. Pricing Electricity in Pools With Wind Producers

    DEFF Research Database (Denmark)

    Morales González, Juan Miguel; Conejo, A. J.; Kai Liu

    2012-01-01

    This paper considers an electricity pool that includes a significant number of wind producers and is cleared through a network-constrained auction, one day in advance and on an hourly basis. The hourly auction is formulated as a two-stage stochastic programming problem, where the first stage...... represents the clearing of the market and the second stage models the system operation under a number of plausible wind production realizations. This formulation co-optimizes energy and reserve, and allows deriving both pool energy prices and balancing energy prices. These prices result in both cost recovery...... for producers and revenue reconciliation. A case study of realistic size is used to illustrate the functioning of the proposed pricing scheme....

  18. Pool type liquid metal fast breeder reactors

    International Nuclear Information System (INIS)

    Guthrie, B.M.

    1978-08-01

    Various technical aspects of the liquid metal fast breeder reactor (LMFBR), specifically pool type LMFBR's, are summarized. The information presented, for the most part, draws upon existing data. Special sections are devoted to design, technical feasibility (normal operating conditions), and safety (accident conditions). A survey of world fast reactors is presented in tabular form, as are two sets of reference reactor parameters based on available data from present and conceptual LMFBR's. (auth)

  19. Condensation of vapor bubble in subcooled pool

    Science.gov (United States)

    Horiuchi, K.; Koiwa, Y.; Kaneko, T.; Ueno, I.

    2017-02-01

    We focus on condensation process of vapor bubble exposed to a pooled liquid of subcooled conditions. Two different geometries are employed in the present research; one is the evaporation on the heated surface, that is, subcooled pool boiling, and the other the injection of vapor into the subcooled pool. The test fluid is water, and all series of the experiments are conducted under the atmospheric pressure condition. The degree of subcooling is ranged from 10 to 40 K. Through the boiling experiment, unique phenomenon known as microbubble emission boiling (MEB) is introduced; this phenomenon realizes heat flux about 10 times higher than the critical heat flux. Condensation of the vapor bubble is the key phenomenon to supply ambient cold liquid to the heated surface. In order to understand the condensing process in the MEB, we prepare vapor in the vapor generator instead of the evaporation on the heated surface, and inject the vapor to expose the vapor bubble to the subcooled liquid. Special attention is paid to the dynamics of the vapor bubble detected by the high-speed video camera, and on the enhancement of the heat transfer due to the variation of interface area driven by the condensation.

  20. Gene pool conservation of teak in Myanmar

    International Nuclear Information System (INIS)

    Tin-Tun

    1995-01-01

    Myanmar with an area of 261, 228 Sq. miles is endowed with various types of forests which occupied nearly 50% of the country. Teak (Tectona grandis Linn. f.) is one of the most valuable timber species for its excellent wood quality and properties which are not observed with other timbers. Gene pool can be defined as a group of individual trees growing over a wide range of environmental conditions, and constituting different genetic complexes which can be transmitted to the offsprings. Topics such as: objectives of gene pool conservation, genetically improved seeds for large scale forest plantations, methodology of conservation, are discussed in the article. Myanmar teak dominates the world's teak market, and thus it is crucial to maintain the superiority in the conservation of gene complexes of teak. To some extent, the conservation of gene pools of teak and tree improvements are being undertaken by the Forest Research Institute of Myanmar. It is felt that the dissemination of the philosophy and concept of gene conservation to the personal involved in the forestry activities of the country are still inadequate

  1. Cost-competitive, inherently safe LFMBR pool plant

    International Nuclear Information System (INIS)

    McDonald, J.S.; Brunings, J.E.; Chang, Y.I.; Hren, R.R.; Seidensticker, R.W.

    1984-01-01

    The Cost-Competitive, Inherently Safe LMFBR Pool Plant design was prepared in GFY 1983 under a DOE-sponsored program. This plant design was developed as a joint effort by Rockwell International and the Argonne National Laboratory with major contributions from the Bechtel Group, Inc.; Combustion engineering, Inc.; the Chicago Bridge and Iron Company; and the General Electric Company. Using current LMFBR technology, many innovative features were developed and incorporated into the design to meet the ultimate objectives of the Breeder Program, i.e., energy costs competitive with LWRs and inherent safety features to maintain the plant in a safe condition following assumed accidents without requiring operator action. This paper provides a description of the principal features that were incorporated into the design to achieve low cost and inherent safety

  2. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    King, V.

    2000-01-01

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous

  3. Fe atom exchange between aqueous Fe2+ and magnetite.

    Science.gov (United States)

    Gorski, Christopher A; Handler, Robert M; Beard, Brian L; Pasakarnis, Timothy; Johnson, Clark M; Scherer, Michelle M

    2012-11-20

    The reaction between magnetite and aqueous Fe(2+) has been extensively studied due to its role in contaminant reduction, trace-metal sequestration, and microbial respiration. Previous work has demonstrated that the reaction of Fe(2+) with magnetite (Fe(3)O(4)) results in the structural incorporation of Fe(2+) and an increase in the bulk Fe(2+) content of magnetite. It is unclear, however, whether significant Fe atom exchange occurs between magnetite and aqueous Fe(2+), as has been observed for other Fe oxides. Here, we measured the extent of Fe atom exchange between aqueous Fe(2+) and magnetite by reacting isotopically "normal" magnetite with (57)Fe-enriched aqueous Fe(2+). The extent of Fe atom exchange between magnetite and aqueous Fe(2+) was significant (54-71%), and went well beyond the amount of Fe atoms found at the near surface. Mössbauer spectroscopy of magnetite reacted with (56)Fe(2+) indicate that no preferential exchange of octahedral or tetrahedral sites occurred. Exchange experiments conducted with Co-ferrite (Co(2+)Fe(2)(3+)O(4)) showed little impact of Co substitution on the rate or extent of atom exchange. Bulk electron conduction, as previously invoked to explain Fe atom exchange in goethite, is a possible mechanism, but if it is occurring, conduction does not appear to be the rate-limiting step. The lack of significant impact of Co substitution on the kinetics of Fe atom exchange, and the relatively high diffusion coefficients reported for magnetite suggest that for magnetite, unlike goethite, Fe atom diffusion is a plausible mechanism to explain the rapid rates of Fe atom exchange in magnetite.

  4. Numerical investigation on natural convection and solidification of molten pool with OpenFOAM

    International Nuclear Information System (INIS)

    Wang Xi; Meng Zhaocan; Cheng Xu

    2015-01-01

    The in-vessel retention is adopted by the third generation nuclear power technology as an important severe accident mitigation strategy. The integrity of reactor pressure vessel depends on the heat flux distribution of molten pool. In present study, the solidification model in open source CFD software OpenFOAM was applied to simulate solidification and natural convection which was driven by internal heat source or temperature difference. The stratified molten pool heat transfer experiment carried out by Royal Institute of Technology was analyzed in the paper, and the solidified crust, temperature and heat flux distributions were obtained. The simulation results were compared with experimental data. It is shown that this numerical method can be used in the simulation of natural convection and solidification of molten pool, and it will probably be used in the analysis of molten corium behavior in reactor lower head. (authors)

  5. Infections Unlikely to be Spread Through Swimming Pools

    Science.gov (United States)

    ... Water Home Infections Unlikely to be Spread Through Swimming Pools Language: English (US) Español (Spanish) Recommend on ... included below. Infections Unlikely to be Spread by Swimming Pools Head Lice Head lice are unlikely to ...

  6. Thermal analyses of solar swimming pool heating in Pakistan

    International Nuclear Information System (INIS)

    Ahmad, I.

    2011-01-01

    Hotels and swimming clubs in Pakistan pay huge gas bills for heating Swimming pools in winter. Winter days in most parts of Pakistan remain sunny and unglazed low cost solar collectors may be used to extend the swimming season. Installing the pool in a wind-protected area, which receives unobstructed solar radiation, may further reduce the size of the solar collectors required to heat the swimming pools. The pools should be covered with plastic sheet to eliminate evaporative heat losses and to prevent dust and tree leaves falling in the pool. The results of the thermal analysis show that in some parts of the country, a solar exposed pool can maintain comfortable temperature simply by using a plastic sheet on the pool surface. On the other hand, there are cities where solar collector array equal to twice the surface area of the pool is required to keep desired temperature in winter. (author)

  7. Analysis of sodium pool fire in SFEF for assessing the limiting pool fire

    International Nuclear Information System (INIS)

    Mangarjuna Rao, P.; Ramesh, S.S.; Nashine, B.K.; Kasinathan, N.; Chellapandi, P.

    2011-01-01

    Accidental sodium leaks and resultant sodium fires in Liquid Metal Fast Breeder Reactor (LMFBR) systems can create a threat to the safe operation of the plant. To avoid this defence-in depth approach is implemented from the design stage of reactor itself. Rapid detection of sodium leak and fast dumping of the sodium into the storage tank of a defective circuit, leak collection trays, adequate lining of load bearing structural concrete and extinguishment of the sodium fire are the important defensive measures in the design, construction and operation of a LMFBR for protection against sodium leaks and their resultant fires. Evaluation of sodium leak events and their consequences by conducting large scale engineering experiments is very essential for effective implementation of the above protection measures for sodium fire safety. For this purpose a Sodium Fire Experimental Facility (SFEF) is constructed at SED, IGCAR. SFEF is having an experimental hall of size 9 m x 6 m x 10 m with 540 m 3 volume and its design pressure is 50 kPa. It is a concrete structure and provided with SS 304 liner, which is fixed to the inside surfaces of walls, ceiling and floor. A leak tight door of size (1.8 m x 2.0 m) is provided to the experimental hall and the facility is provided with a sodium equipment hall and a control room. Experimental evaluation of sodium pool fire consequences is an important activity in the LMFBR sodium fire safety related studies. An experimental program has been planned for different types of sodium fire studies in SFEF. A prior to that numerical analysis have been carried out for enclosed sodium pool fires using SOFIRE-II sodium pool fire code for SFEF experimental hall configuration to evaluate the limiting pool fire. This paper brings out results of the analysis carried out for this purpose. Limiting pool fire of SFEF depends on the exposed surface area of the pool, amount of sodium in the pool, oxygen concentration and initial sodium temperature. Limiting

  8. (Important hygienic aspects for swimming pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Somosi, G

    1981-01-01

    The major epidemics which occurred in Hungary and originated from water in swimming pools are reported. The difficulties encountered in producing epidemiological evidence and in monitoring infections originating from water in swimming pools are mentioned. The possibilities of controlling the water quality in swimming pools and of preventing infections are discussed. Reference is made to the existing bacteriological limit values in Hungary to be observed in the recirculation of water in swimming pools.

  9. Storage of water reactor spent fuel in water pools. Survey of world experience

    International Nuclear Information System (INIS)

    1982-01-01

    Following discharge from a nuclear reactor, spent fuel has to be stored in water pools at the reactor site to allow for radioactive decay and cooling. After this initial storage period, the future treatment of spent fuel depends on the fuel cycle concept chosen. Spent fuel can either be treated by chemical processing or conditioning for final disposal at the relevant fuel cycle facilities, or be held in interim storage - at the reactor site or at a central storage facility. Recent forecasts predict that, by the year 2000, more than 150,000 tonnes of heavy metal from spent LWR fuel will have been accumulated. Because of postponed commitments regarding spent fuel treatment, a significant amount of spent fuel will still be held in storage at that time. Although very positive experience with wet storage has been gained over the past 40 years, making wet storage a proven technology, it appears desirable to summarize all available data for the benefit of designers, storage pool operators, licensing agenices and the general public. Such data will be essential for assessing the viability of extended water pool storage of spent nuclear fuel. In 1979, the International Atomic Energy Agency and the Nuclear Energy Agency of the OECD jointly issued a questionnaire dealing with all aspects of water pool storage. This report summarizes the information received from storage pool operators

  10. NACUBO's Guide to Unitizing Investment Pools. Second Edition

    Science.gov (United States)

    Wheeler, Mary S.

    2011-01-01

    The National Association of College and University Business Officers' (NACUBO's) "Guide to Unitizing Investment Pools" addresses the principles and concepts for administering a consolidated investment pool. Unitization is the mechanism by which investment funds are pooled to maximize investment efficiencies and provide information for donors,…

  11. A skeleton for distributed work pools in Eden

    DEFF Research Database (Denmark)

    Dieterle, Mischa; Berthold, Jost; Loogen, Rita

    2010-01-01

    We present a flexible skeleton for implementing distributed work pools in our parallel functional language Eden. The skeleton manages a pool of tasks (work pool) in a distributed manner using a demand-driven work stealing approach for load balancing. All coordination is done locally within...

  12. Opportunities and challenges when pooling milk samples using ELISA

    DEFF Research Database (Denmark)

    Græsbøll, Kaare; Andresen, Lars Ole; Hisham Beshara Halasa, Tariq

    2017-01-01

    -positive samples by pooling. To illustrate this, the sensitivity of antibody ELISA on pooled samples of bovine milk for Salmonella Dublin, Mycobacterium avium spp. paratuberculosis, and bovine virus diarrhea was tested. For these milk assays, the analytical sensitivity decreased rapidly with increasing pool sizes...

  13. 48 CFR 873.114 - Best value pool.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Best value pool. 873.114... SUPPLEMENTARY REGULATIONS SIMPLIFIED ACQUISITION PROCEDURES FOR HEALTH-CARE RESOURCES 873.114 Best value pool... solicitation. These vendors constitute the best value pool. This determination is within the sole discretion of...

  14. Mtr Extracellular Electron Transfer Pathways in Fe(III)-reducing or Fe(II)-oxidizing Bacteria: A Genomic Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Liang; Rosso, Kevin M.; Zachara, John M.; Fredrickson, Jim K.

    2012-12-01

    Originally discovered in the dissimilatory metal-reducing bacterium Shewanella oneidensis MR-1 (MR-1), the Mtr (i.e., metal-reducing) pathway exists in all characterized strains of metal-reducing Shewanella. The protein components identified to date for the Mtr pathway of MR-1 include four multi-heme c-type cytochromes (c-Cyts), CymA, MtrA, MtrC and OmcA, and a porin-like, outer membrane protein MtrB. They are strategically positioned along the width of the MR-1 cell envelope to mediate electron transfer from the quinone/quinol pool in the inner-membrane to the Fe(III)-containing minerals external to the bacterial cells. A survey of microbial genomes revealed homologues of the Mtr pathway in other dissimilatory Fe(III)-reducing bacteria, including Aeromonas hydrophila, Ferrimonas balearica and Rhodoferax ferrireducens, and in the Fe(II)-oxidizing bacteria Dechloromonas aromatica RCB, Gallionella capsiferriformans ES-2 and Sideroxydans lithotrophicus ES-1. The widespread distribution of Mtr pathways in Fe(III)-reducing or Fe(II)-oxidizing bacteria emphasizes the importance of this type of extracellular electron transfer pathway in microbial redox transformation of Fe. Their distribution in these two different functional groups of bacteria also emphasizes the bi-directional nature of electron transfer reactions carried out by the Mtr pathways. The characteristics of the Mtr pathways may be shared by other pathways used by microorganisms for exchanging electrons with their extracellular environments.

  15. On the origin of discontinuity of the hyperfine fields at {sup 57}Fe nuclei in bulk iron and aerosol Fe nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Yu.I. [Semenov Institute of Chemical Physics, Russian Academy of Sciences, Kosygin str. 4, 119991, GSP-1, Moscow (Russian Federation); Shafranovsky, E.A., E-mail: shafr@chph.ras.r [Semenov Institute of Chemical Physics, Russian Academy of Sciences, Kosygin str. 4, 119991, GSP-1, Moscow (Russian Federation); Casas, Ll. [Departament de Geologia, Universitat Autonoma de Barcelona, Edifici C, Campus de la UAB, 08193 Bellaterra (Spain); Molins, E. [Institut de Ciencia de Materials de Barcelona (ICMAB-CSIC), Campus de la UAB, 08193 Bellaterra (Spain)

    2011-03-14

    Advancing the early work in which a discontinuity of hyperfine fields at {sup 57}Fe nuclei in bulk iron and in aerosol Fe nanoparticles has been revealed by analyzing their Moessbauer spectra the present Letter evidences that the existence of several peaks in the hyperfine distribution (HFD) for bulk Fe is caused with the internal magnetic fields owing to its multidomain structure whereas aerosol Fe nanoparticles are single-domain and show only a unique peak in HFD. This argument has been corroborated by transformation of the HFD pattern for Fe foil after applying the external magnetic field of 0.03 T.

  16. Measurements in large JP-4 pool fires

    International Nuclear Information System (INIS)

    Keltner, N.R.; Kent, L.A.; Schneider, M.E.

    1987-01-01

    Over the past four years, Sandia National Laboratories has conducted a number of large pool fire tests to evaluate the design of radioactive material (RAM) shipping containers. Some of these tests have been designed to define the thermal environment and some have been used for certification testing. In each test there have been a number of fire diagnostic measurements. The simplest sets of diagnostics have involved measurements of temperature at several elevations on arrays of towers, measurements of hot wall heat flux with small calorimeters suspended from the towers, the average fuel recession rate, and the wind speed and direction. The most complex sets of diagnostics have included the above and in various tests added radiometers in the lower flame zone, centerline velocity measurements at a number of elevations, radiometers and calorimeters at the fuel surface, large cylindrical and flat plate calorimeters, infrared imaging, time resolved fuel recession rates, and a variety of soot particle concentration and size measurements made in the plume with a tethered balloon and an instrumented airplane. All of the large fires have been conducted in a 9.1 m by 18.3 m pool using JP-4 as the fuel. Typical duration is one-half hour. Covering all of the results is beyond the scope of a single paper. Conditionally sampled temperature and velocity measurements from one fire will be presented; for this fire, a 20 cm layer of fuel was floated on 61 cm of water. Pool surface heat flux, fuel recession rate data, and smoke emission data from a second fire are given. Because the wind has a strong effect on the temperature and velocity measurements, conditional sampling has been used to try to obtain data during periods of low winds. 10 refs., 3 figs

  17. Moessbauer study of Fe-Co nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Chen Ziyu [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou (China)]. E-mail: chenzy@lzu.edu.cn; Zhan Qingfeng; Xue Desheng; Li Fashen [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou (China); Zhou Xuezhi; Kunkel, Henry; Williams, Gwyn [Department of Physics and Astronomy, the University of Manitoba (Canada)

    2002-01-28

    Arrays of Fe{sub 1-x}Co{sub x} (0.0{<=}x{<=}0.92) nanowires have been prepared by an electrochemical process, co-depositing Fe and Co atoms into the pores of anodic aluminium; their compositions were determined by atomic absorption spectroscopy. Transmission electron microscope results show that the nanowires are regularly spaced and uniform in shape with lengths of about 7.5 {mu}m and diameters of 20 nm. The x-ray diffraction indicates a texture in the deposited nanowires. For the composition below 82 at.% cobalt, the nanowires had a body-centred-cubic structure with a [110] preferred orientation. For the 92 at.% cobalt sample, the alloy exhibited a mixture of bcc and face-centred-cubic structure. The room temperature {sup 57}Fe Moessbauer spectra of the arrays of Fe{sub 1-x}Co{sub x} nanowires have second and fifth absorption lines of the six-line pattern with almost zero intensity, indicating that the internal magnetic field in the nanowires lies along the long axis of the nanowire. The maximum values of the hyperfine field (B{sub hf} 36.6{+-}0.1 T) and isomer shift (IS=0.06{+-}0.01 mm s-1) occur for 44 at.% cobalt. The variations of the isomer shift and the linewidths with composition indicate that the Fe{sub 1-x}Co{sub x} alloy nanowires around the equiatomic composition are in an atomistic disordered state. (author)

  18. Gated cardiac blood pool studies in arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed [fr

  19. Pool boiling visualization on open microchannel surfaces

    Directory of Open Access Journals (Sweden)

    Kaniowski Robert

    2017-01-01

    Full Text Available The paper presents visualization investigations into pool boiling heat transfer for open minichannel surfaces. The experiments were carried out wih saturated water at atmospheric pressure. Parallel microchannels fabricated by machining were about 0.3 mm wide and 0.2 to 0.4 mm deep. High-speed videos were used as an aid to understanding the heat transfer mechanism. The visualization study aimed at identifying nucleation sites of the departing bubbles and determining their diameters and frequency at various superheats.

  20. Simulation of a pool type research reactor

    International Nuclear Information System (INIS)

    Oliveira, Andre Felipe da Silva de; Moreira, Maria de Lourdes

    2011-01-01

    Computational fluid dynamic is used to simulate natural circulation condition after a research reactor shutdown. A benchmark problem was used to test the viability of usage such code to simulate the reactor model. A model which contains the core, the pool, the reflector tank, the circulation pipes and chimney was simulated. The reactor core contained in the full scale model was represented by a porous media. The parameters of porous media were obtained from a separate CFD analysis of the full core model. Results demonstrate that such studies can be carried out for research and test of reactors design. (author)

  1. Gated cardiac blood pool studies in arrhythmias

    Energy Technology Data Exchange (ETDEWEB)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed.

  2. Pool film boiling heat transfer, 5

    International Nuclear Information System (INIS)

    Sakurai, A.; Shiotsu, M.; Hata, K.

    1981-01-01

    Steady minimum film boiling heat flux and temperature were experimentally studied for a horizontal cylinder test heater in a pool of saturated water under pressures ranging from 0.1 to 2 MPa. Minimum temperature of film boiling may be determined by hydrodynamic Taylor instability for the pressures lower than around 1.0 MPa and by homogeneous nucleation temperature for the higher pressures. However, conventional correlations of minimum heat flux based on the hydrodynamic Taylor instability cannot at all predict the pressure dependency of the experimental data in the lower pressure region. Semi-empirical equation of the minimum heat flux based on the hydrodynamic Taylor instability was given. (author)

  3. Swimming pool reactor reliability and safety analysis

    International Nuclear Information System (INIS)

    Li Zhaohuan

    1997-01-01

    A reliability and safety analysis of Swimming Pool Reactor in China Institute of Atomic Energy is done by use of event/fault tree technique. The paper briefly describes the analysis model, analysis code and main results. Meanwhile it also describes the impact of unassigned operation status on safety, the estimation of effectiveness of defense tactics in maintenance against common cause failure, the effectiveness of recovering actions on the system reliability, the comparison of occurrence frequencies of the core damage by use of generic and specific data

  4. Numerical investigation of the reactor pressure vessel behaviour under severe accident conditions taking into account the combined processes of the vessel creep and the molten pool natural convection

    International Nuclear Information System (INIS)

    Loktionov, V.D.; Mukhtarov, E.S.; Yaroshenko, N.I.; Orlov, V.E.

    1999-01-01

    Analysis of the WWER lower head behaviour and its failure has been performed for several molten pool structures and internal overpressure levels in a reactor pressure vessel (RPV). The different types of the molten pools (homogeneous, conventionally homogeneous, conventionally stratified, stratified) cover the bounding scenarios during a hypothetical severe accident. The parametric investigations of the failure mode and RPV behaviour for various molten pool types, its heights and internal overpressure levels are presented herein. A coupled treatment in this investigation includes: (i) a 2-D thermohydraulic analysis of a molten pool natural convection. Domestic NARAUFEM code has been used in this detailed analysis for prediction of the heat flux from the molten pool to the RPV inner surface; and (ii) a detailed 3-D transient thermal analysis of the RPV lower head. Domestic 3-D ASHTER-VVR finite element code has been used for the numerical simulations of the high temperature creep and failure of the lower head. The effect of an external RPV cooling, temperature-dependent physical properties of the molten pool and vessel steel, the hydrostatic forces and vessel dead-weight were taken into account in this study. The obtained results show that lower head failure occurs as a result of the vessel creep process which is significantly dependent on both an internal overpressure level and the type of molten pool structure. In particular, it was found that there were combinations of 'overpressure-molten pool structure' when the vessel failure started at the 'hot' layers of the vessel. (orig.)

  5. Reliability and Concurrent Validity of the International Personality ...

    African Journals Online (AJOL)

    Reliability and Concurrent Validity of the International Personality item Pool (IPIP) Big-five Factor Markers in Nigeria. ... Nigerian Journal of Psychiatry ... Aims: The aim of this study was to assess the internal consistency and concurrent validity ...

  6. A method of measuring a molten metal liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M., Donaldson, A.D.

    1990-12-12

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.

  7. Switchable transport strategy to deposit active Fe/Fe3C cores into hollow microporous carbons for efficient chromium removal.

    Science.gov (United States)

    Liu, Dong-Hai; Guo, Yue; Zhang, Lu-Hua; Li, Wen-Cui; Sun, Tao; Lu, An-Hui

    2013-11-25

    Magnetic hollow structures with microporous shell and highly dispersed active cores (Fe/Fe3 C nanoparticles) are rationally designed and fabricated by solution-phase switchable transport of active iron species combined with a solid-state thermolysis technique, thus allowing selective encapsulation of functional Fe/Fe3 C nanoparticles in the interior cavity. These engineered functional materials show high loading (≈54 wt%) of Fe, excellent chromium removal capability (100 mg g(-1)), fast adsorption rate (8766 mL mg(-1) h(-1)), and easy magnetic separation property (63.25 emu g(-1)). During the adsorption process, the internal highly dispersed Fe/Fe3 C nanoparticles supply a driving force for facilitating Cr(VI) diffusion inward, thus improving the adsorption rate and the adsorption capacity. At the same time, the external microporous carbon shell can also efficiently trap guest Cr(VI) ions and protect Fe/Fe3 C nanoparticles from corrosion and subsequent leaching problems. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Study of mixed convection in sodium pool

    International Nuclear Information System (INIS)

    Wang Zhou; Chen Yan

    1995-01-01

    The mixed convection phenomena in the sodium pool of fast reactor have been studied systematically by the two dimensional modeling method. A generalized concept of circumferential line in the cylindrical coordinates was proposed to overcome the three dimensional effect induced by the pool geometry in an analysis of two dimensional modeling. A method of sub-step in time was developed for solving the turbulent equations. The treatments on the boundary condition for the auxiliary velocity field have been proposed, and the explanation of allowing the flow function method to be used in the flow field in presence of a mass source term was given. As examples of verification, the experiments were conducted with water flow in a rectangular cavity. The results from theoretical analysis were applied to the numerical computation for the mixed convection in the cavity. The mechanism of stratified flow in the cavity was studied. A numerical calculation was carried out for the mixed convection in hot plenum of a typical fast reactor

  9. Visual attention and flexible normalization pools

    Science.gov (United States)

    Schwartz, Odelia; Coen-Cagli, Ruben

    2013-01-01

    Attention to a spatial location or feature in a visual scene can modulate the responses of cortical neurons and affect perceptual biases in illusions. We add attention to a cortical model of spatial context based on a well-founded account of natural scene statistics. The cortical model amounts to a generalized form of divisive normalization, in which the surround is in the normalization pool of the center target only if they are considered statistically dependent. Here we propose that attention influences this computation by accentuating the neural unit activations at the attended location, and that the amount of attentional influence of the surround on the center thus depends on whether center and surround are deemed in the same normalization pool. The resulting form of model extends a recent divisive normalization model of attention (Reynolds & Heeger, 2009). We simulate cortical surround orientation experiments with attention and show that the flexible model is suitable for capturing additional data and makes nontrivial testable predictions. PMID:23345413

  10. Hardening Stratum, the Bitcoin Pool Mining Protocol

    Directory of Open Access Journals (Sweden)

    Recabarren Ruben

    2017-07-01

    Full Text Available Stratum, the de-facto mining communication protocol used by blockchain based cryptocurrency systems, enables miners to reliably and efficiently fetch jobs from mining pool servers. In this paper we exploit Stratum’s lack of encryption to develop passive and active attacks on Bitcoin’s mining protocol, with important implications on the privacy, security and even safety of mining equipment owners. We introduce StraTap and ISP Log attacks, that infer miner earnings if given access to miner communications, or even their logs. We develop BiteCoin, an active attack that hijacks shares submitted by miners, and their associated payouts. We build BiteCoin on WireGhost, a tool we developed to hijack and surreptitiously maintain Stratum connections. Our attacks reveal that securing Stratum through pervasive encryption is not only undesirable (due to large overheads, but also ineffective: an adversary can predict miner earnings even when given access to only packet timestamps. Instead, we devise Bedrock, a minimalistic Stratum extension that protects the privacy and security of mining participants. We introduce and leverage the mining cookie concept, a secret that each miner shares with the pool and includes in its puzzle computations, and that prevents attackers from reconstructing or hijacking the puzzles.

  11. Estimated environmental radionuclide transfer and deposition into outdoor swimming pools

    International Nuclear Information System (INIS)

    Tagami, Kazumi; Nagata, Izumi; Sueki, Keisuke

    2014-01-01

    In 2011, a large radioactive discharge occurred at the Fukushima Daiichi nuclear power plant. This plant is located within a climatically temperate region where outdoor swimming pools are popular. Although it is relatively easy to decontaminate pools by refilling them with fresh water, it is difficult to maintain safe conditions given highly contaminated diurnal dust falls from the surrounding contaminated ground. Our objectives in this paper were to conduct daily radioactivity measurements, to determine the quantity of radioactive contaminants from the surrounding environment that invade outdoor pools, and to investigate the efficacy of traditional pool cleaners in removing radioactive contaminants. The depositions in the paper filterable particulates ranged from 0 to 62,5 Bq/m 2 /day, with the highest levels found in the southern Tohoku District containing Fukushima Prefecture and in the Kanto District containing Tokyo Metro. They were approximately correlated with the ground contamination. Traditional pool cleaners eliminated 99% of contaminants at the bottom of the pool, reducing the concentration to 41 Bq/m 2 after cleaning. Authors recommended the deposition or the blown radionuclides into outdoor swimming pools must be considered into pool regulations when the environments exactly polluted with radionuclides. - Highlights: • Deposition into outdoor swimming pool in a habitable areas estimated 72 Bq/m 2 /day. • More than 500 Bq/m 2 /day deposition will exceed our national guideline (10 Bq/l) of swimming pool. • Vacuum pool cleaner eliminates 99% radionuclides deposition

  12. Plant diversity associated with pools in natural and restored peatlands

    Directory of Open Access Journals (Sweden)

    N. Fontaine

    2007-06-01

    Full Text Available This study describes plant assemblages associated with the edges of peatland pools. We conducted inventories in six natural peatlands in the province of Québec (Canada in order to measure the contribution of pools to species diversity in climatic regions where peatlands are used for peat extraction. We also carried out vegetation surveys in a peatland that has been restored after peat extraction/harvesting to determine whether pool vegetation establishes along the edges of created pools when dry surface restoration techniques only are used. Pools enhanced plant species richness in natural peatlands. Around created pools, species associated with natural pools were still absent, and non-bog species were present, six years after restoration. On this basis, we emphasise the importance of preserving natural peatlands with pools. In order to restore fully the plant diversity associated with peatlands at harvested sites, it may be necessary to modify pool excavation techniques so that created pools resemble more closely those in natural peatlands. Active introduction of the plant species or communities associated with natural pools may also be needed; candidate species for North America include Andromeda glaucophylla, Cladopodiella fluitans, Carex limosa, Eriophorum virginicum, Rhynchospora alba and Sphagnum cuspidatum.

  13. Life cycle environmental implications of residential swimming pools.

    Science.gov (United States)

    Forrest, Nigel; Williams, Eric

    2010-07-15

    Ownership of private swimming pools in the U.S. grew 2 to 4% per annum from 1997 to 2007. The environmental implications of pool ownership are analyzed by hybrid life cycle assessment (LCA) for nine U.S. cities. An operational model is constructed estimating consumption of chemicals, water, and energy for a typical residential pool. The model incorporates geographical climatic variations and upstream water and energy use from electricity and water supply networks. Results vary considerably by city: a factor of 5-6 for both water and energy use. Water use is driven by aridness and length of the swimming season, while energy use is mainly driven by length of the swimming season. Water and energy impacts of pools are significant, particularly in arid climates. In Phoenix for example pools account for 22% and 13% of a household's electricity and water use, respectively. Measures to reduce water and energy use in pools such as optimizing the pump schedule and covering the pool in winter can realize greater savings than many common household efficiency improvements. Private versus community pools are also compared. Community pools in Phoenix use 60% less swimming pool water and energy per household than subdivisions without community pools.

  14. Reduction of the pool-top radiation level in HANARO

    International Nuclear Information System (INIS)

    Lee, Choong-Sung; Park, Sang-Jun; Kim, Heonil; Park, Yong-Chul; Choi, Young-San

    1999-01-01

    HANARO is an open-tank-in-pool type reactor. Pool water is the only shielding to minimize the pool top radiation level. During the power ascension test of HANARO, the measured pool top radiation level was higher than the design value because some of the activation products in the coolant reached the pool surface. In order to suppress this rising coolant, the hot water layer system (HWL) was designed and installed to maintain l.2 meter-deep hot water layer whose temperature is 5degC higher than that of the underneath pool surface. After the installation of the HWL system, however, the radiation level of the pool-top did not satisfy the design value. The operation modes of the hot water layer system and the other systems in the reactor pool, which had an effect on the formation of the hot water layer, were changed to reduce pool-top radiation level. After the above efforts, the temperature and the radioactivity distribution in the pool was measured to confirm whether this system blocked the rising coolant. The radiation level at the pool-top was significantly reduced below one tenth of that before installing the HWL and satisfied the design value. It was also confirmed by calculation that this hot water layer system would significantly reduce the release of fission gases to the reactor hall and the environment during the hypothetical accident as well. (author)

  15. Design of inventory pools in spare part support operation systems

    Science.gov (United States)

    Mo, Daniel Y.; Tseng, Mitchell M.; Cheung, Raymond K.

    2014-06-01

    The objective of a spare part support operation is to fulfill the part request order with different service contracts in the agreed response time. With this objective to achieve different service targets for multiple service contracts and the considerations of inventory investment, it is not only important to determine the inventory policy but also to design the structure of inventory pools and the order fulfilment strategies. In this research, we focused on two types of inventory pools: multiple inventory pool (MIP) and consolidated inventory pool (CIP). The idea of MIP is to maintain separated inventory pools based on the types of service contract, while CIP solely maintains a single inventory pool regardless of service contract. Our research aims to design the inventory pool analytically and propose reserve strategies to manage the order fulfilment risks in CIP. Mathematical models and simulation experiments would be applied for analysis and evaluation.

  16. Behavior of spent nuclear fuel in water pool storage

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.

    1977-09-01

    Storage of irradiated nuclear fuel in water pools (basins) has been standard practice since nuclear reactors first began operation approximately 34 years ago. Pool storage is the starting point for all other fuel storage candidate processes and is a candidate for extended interim fuel storage until policy questions regarding reprocessing and ultimate disposal have been resolved. This report assesses the current performance of nuclear fuel in pool storage, the range of storage conditions, and the prospects for extending residence times. The assessment is based on visits to five U.S. and Canadian fuel storage sites, representing nine storage pools, and on discussions with operators of an additional 21 storage pools. Spent fuel storage experience from British pools at Winfrith and Windscale and from a German pool at Karlsruhe (WAK) also is summarized

  17. Investigation of the condition of spent-fuel pool components

    International Nuclear Information System (INIS)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts

  18. Decontamination of outdoor school swimming pools in Fukushima

    International Nuclear Information System (INIS)

    Saegusa, Jun

    2013-01-01

    After the Fukushima Daiichi NPP accident following the Great East Japan Earthquake, many school swimming pools in Fukushima have suspended water discharge, due to concerns that pool water which contains radioactive fallout is discharged into a river or waterway for agricultural use. The Japan Atomic Energy Agency conducted researches and examinations on the existing absorbent method and the flocculation method as ways for decontaminating pool water. By reviewing and improving these methods through decontamination demonstrations at eight pools in Fukushima, a practical decontamination method for outdoor pools has been established. This report summarizes the methods and results of the decontamination demonstrations carried out at the schools. Also, the surface density of fallout estimated at one of the pools is also presented and discussed in connection with the overall collection ratio of radiocesium at the pool. (author)

  19. Investigation of the condition of spent-fuel pool components

    Energy Technology Data Exchange (ETDEWEB)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts.

  20. The 54Fe(d,t)53Fe reaction and the neutron configuration in 54Fe

    International Nuclear Information System (INIS)

    England, J.B.A.; Ophel, T.R.; Johnston, A.; Zeller, A.F.

    1980-07-01

    The 54 Fe(d,t) 53 Fe reaction has been used to study the levels populated in 54 Fe in an attempt to establish the neutron configuration in 54 Fe. The states observed show clear evidence for a 2p-4h admixture in 54 Fe. In particular, the strength of the first 3/2 - level relative to the 7/2 - ground state transition is 3-4 times that in neighbouring N = 28 nuclei

  1. HLM fuel pin bundle experiments in the CIRCE pool facility

    Energy Technology Data Exchange (ETDEWEB)

    Martelli, Daniele, E-mail: daniele.martelli@ing.unipi.it [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Forgione, Nicola [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Di Piazza, Ivan; Tarantino, Mariano [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone (Italy)

    2015-10-15

    Highlights: • The experimental results represent the first set of values for LBE pool facility. • Heat transfer is investigated for a 37-pin electrical bundle cooled by LBE. • Experimental data are presented together with a detailed error analysis. • Nu is computed as a function of the Pe and compared with correlations. • Experimental Nu is about 25% lower than Nu derived from correlations. - Abstract: Since Lead-cooled Fast Reactors (LFR) have been conceptualized in the frame of GEN IV International Forum (GIF), great interest has focused on the development and testing of new technologies related to HLM nuclear reactors. In this frame the Integral Circulation Experiment (ICE) test section has been installed into the CIRCE pool facility and suitable experiments have been carried out aiming to fully investigate the heat transfer phenomena in grid spaced fuel pin bundles providing experimental data in support of European fast reactor development. In particular, the fuel pin bundle simulator (FPS) cooled by lead bismuth eutectic (LBE), has been conceived with a thermal power of about 1 MW and a uniform linear power up to 25 kW/m, relevant values for a LFR. It consists of 37 fuel pins (electrically simulated) placed on a hexagonal lattice with a pitch to diameter ratio of 1.8. The FPS was deeply instrumented by several thermocouples. In particular, two sections of the FPS were instrumented in order to evaluate the heat transfer coefficient along the bundle as well as the cladding temperature in different ranks of sub-channels. Nusselt number in the central sub-channel was therefore calculated as a function of the Peclet number and the obtained results were compared to Nusselt numbers obtained from convective heat transfer correlations available in literature on Heavy Liquid Metals (HLM). Results reported in the present work, represent the first set of experimental data concerning fuel pin bundle behaviour in a heavy liquid metal pool, both in forced and

  2. Combinatorial Pooling Enables Selective Sequencing of the Barley Gene Space

    Science.gov (United States)

    Lonardi, Stefano; Duma, Denisa; Alpert, Matthew; Cordero, Francesca; Beccuti, Marco; Bhat, Prasanna R.; Wu, Yonghui; Ciardo, Gianfranco; Alsaihati, Burair; Ma, Yaqin; Wanamaker, Steve; Resnik, Josh; Bozdag, Serdar; Luo, Ming-Cheng; Close, Timothy J.

    2013-01-01

    For the vast majority of species – including many economically or ecologically important organisms, progress in biological research is hampered due to the lack of a reference genome sequence. Despite recent advances in sequencing technologies, several factors still limit the availability of such a critical resource. At the same time, many research groups and international consortia have already produced BAC libraries and physical maps and now are in a position to proceed with the development of whole-genome sequences organized around a physical map anchored to a genetic map. We propose a BAC-by-BAC sequencing protocol that combines combinatorial pooling design and second-generation sequencing technology to efficiently approach denovo selective genome sequencing. We show that combinatorial pooling is a cost-effective and practical alternative to exhaustive DNA barcoding when preparing sequencing libraries for hundreds or thousands of DNA samples, such as in this case gene-bearing minimum-tiling-path BAC clones. The novelty of the protocol hinges on the computational ability to efficiently compare hundred millions of short reads and assign them to the correct BAC clones (deconvolution) so that the assembly can be carried out clone-by-clone. Experimental results on simulated data for the rice genome show that the deconvolution is very accurate, and the resulting BAC assemblies have high quality. Results on real data for a gene-rich subset of the barley genome confirm that the deconvolution is accurate and the BAC assemblies have good quality. While our method cannot provide the level of completeness that one would achieve with a comprehensive whole-genome sequencing project, we show that it is quite successful in reconstructing the gene sequences within BACs. In the case of plants such as barley, this level of sequence knowledge is sufficient to support critical end-point objectives such as map-based cloning and marker-assisted breeding. PMID:23592960

  3. Combinatorial pooling enables selective sequencing of the barley gene space.

    Directory of Open Access Journals (Sweden)

    Stefano Lonardi

    2013-04-01

    Full Text Available For the vast majority of species - including many economically or ecologically important organisms, progress in biological research is hampered due to the lack of a reference genome sequence. Despite recent advances in sequencing technologies, several factors still limit the availability of such a critical resource. At the same time, many research groups and international consortia have already produced BAC libraries and physical maps and now are in a position to proceed with the development of whole-genome sequences organized around a physical map anchored to a genetic map. We propose a BAC-by-BAC sequencing protocol that combines combinatorial pooling design and second-generation sequencing technology to efficiently approach denovo selective genome sequencing. We show that combinatorial pooling is a cost-effective and practical alternative to exhaustive DNA barcoding when preparing sequencing libraries for hundreds or thousands of DNA samples, such as in this case gene-bearing minimum-tiling-path BAC clones. The novelty of the protocol hinges on the computational ability to efficiently compare hundred millions of short reads and assign them to the correct BAC clones (deconvolution so that the assembly can be carried out clone-by-clone. Experimental results on simulated data for the rice genome show that the deconvolution is very accurate, and the resulting BAC assemblies have high quality. Results on real data for a gene-rich subset of the barley genome confirm that the deconvolution is accurate and the BAC assemblies have good quality. While our method cannot provide the level of completeness that one would achieve with a comprehensive whole-genome sequencing project, we show that it is quite successful in reconstructing the gene sequences within BACs. In the case of plants such as barley, this level of sequence knowledge is sufficient to support critical end-point objectives such as map-based cloning and marker-assisted breeding.

  4. Combinatorial pooling enables selective sequencing of the barley gene space.

    Science.gov (United States)

    Lonardi, Stefano; Duma, Denisa; Alpert, Matthew; Cordero, Francesca; Beccuti, Marco; Bhat, Prasanna R; Wu, Yonghui; Ciardo, Gianfranco; Alsaihati, Burair; Ma, Yaqin; Wanamaker, Steve; Resnik, Josh; Bozdag, Serdar; Luo, Ming-Cheng; Close, Timothy J

    2013-04-01

    For the vast majority of species - including many economically or ecologically important organisms, progress in biological research is hampered due to the lack of a reference genome sequence. Despite recent advances in sequencing technologies, several factors still limit the availability of such a critical resource. At the same time, many research groups and international consortia have already produced BAC libraries and physical maps and now are in a position to proceed with the development of whole-genome sequences organized around a physical map anchored to a genetic map. We propose a BAC-by-BAC sequencing protocol that combines combinatorial pooling design and second-generation sequencing technology to efficiently approach denovo selective genome sequencing. We show that combinatorial pooling is a cost-effective and practical alternative to exhaustive DNA barcoding when preparing sequencing libraries for hundreds or thousands of DNA samples, such as in this case gene-bearing minimum-tiling-path BAC clones. The novelty of the protocol hinges on the computational ability to efficiently compare hundred millions of short reads and assign them to the correct BAC clones (deconvolution) so that the assembly can be carried out clone-by-clone. Experimental results on simulated data for the rice genome show that the deconvolution is very accurate, and the resulting BAC assemblies have high quality. Results on real data for a gene-rich subset of the barley genome confirm that the deconvolution is accurate and the BAC assemblies have good quality. While our method cannot provide the level of completeness that one would achieve with a comprehensive whole-genome sequencing project, we show that it is quite successful in reconstructing the gene sequences within BACs. In the case of plants such as barley, this level of sequence knowledge is sufficient to support critical end-point objectives such as map-based cloning and marker-assisted breeding.

  5. Expanding the live kidney donor pool: ethical considerations regarding altruistic donors, paired and pooled programs.

    Science.gov (United States)

    Patel, Shaneel Rajendra; Chadha, Priyanka; Papalois, Vassilios

    2011-06-01

    In renal transplant, there is a well-known deficiency in organ supply relative to demand. Live donation provides superior results when compared with deceased donation including a better rate of graft success and fewer immunologic complications. This deficiency in organs leads to significant morbidity and mortality rates. Alternative avenues have been extensively explored that may expand the live donor pool. They include altruistic donation as well as paired and pooled exchange programs. Altruistic donation is a truly selfless act from a donor unknown to the recipient. Kidney paired donation involves 2 incompatible donor-recipient pairs swapping donors to produce compatibility. Pooled donation involves at least 2 pairs, and can take the form of domino chains in which altruistic input sets up a chain of transplants, in which each recipient's incompatible donor makes a donation for the next recipient. Despite application of these various methods, there lie extensive ethical issues surrounding them. Misconceptions frequently occur; for instance, the perceived benefit that donating an organ to a loved one is greater for a related donor than for an altruistic one. Additionally, it is frequently believed that immunologic incompatibility offers coerced donors liberation from surgery, and that overcoming these barriers by introducing exchange programs provides vulnerable donors less protection. This article explores these and other complex ethical issues surrounding the various methods of expanding the donor pool. The authors offer opinions that challenge the ethical issues and attempt to overcome those views that hinder progress in the field.

  6. Effect of mitochondrial complex I inhibition on Fe-S cluster protein activity

    Energy Technology Data Exchange (ETDEWEB)

    Mena, Natalia P. [Department of Biology, Faculty of Sciences, Universidad de Chile, Las Palmeras 3425, Santiago (Chile); Millennium Institute of Cell Dynamics and Biotechnology, Santiago (Chile); Bulteau, Anne Laure [UPMC Univ Paris 06, UMRS 975 - UMR 7725, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); Inserm, U 975, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); CNRS, UMR 7225, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, Paris 75013 (France); Salazar, Julio [Millennium Institute of Cell Dynamics and Biotechnology, Santiago (Chile); Hirsch, Etienne C. [UPMC Univ Paris 06, UMRS 975 - UMR 7725, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); Inserm, U 975, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); CNRS, UMR 7225, Centre de Recherche en Neurosciences, ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, F-75005 Paris (France); ICM, Therapeutique Experimentale de la Neurodegenerescence, Hopital de la Salpetriere, Paris 75013 (France); Nunez, Marco T., E-mail: mnunez@uchile.cl [Department of Biology, Faculty of Sciences, Universidad de Chile, Las Palmeras 3425, Santiago (Chile); Millennium Institute of Cell Dynamics and Biotechnology, Santiago (Chile)

    2011-06-03

    Highlights: {yields} Mitochondrial complex I inhibition resulted in decreased activity of Fe-S containing enzymes mitochondrial aconitase and cytoplasmic aconitase and xanthine oxidase. {yields} Complex I inhibition resulted in the loss of Fe-S clusters in cytoplasmic aconitase and of glutamine phosphoribosyl pyrophosphate amidotransferase. {yields} Consistent with loss of cytoplasmic aconitase activity, an increase in iron regulatory protein 1 activity was found. {yields} Complex I inhibition resulted in an increase in the labile cytoplasmic iron pool. -- Abstract: Iron-sulfur (Fe-S) clusters are small inorganic cofactors formed by tetrahedral coordination of iron atoms with sulfur groups. Present in numerous proteins, these clusters are involved in key biological processes such as electron transfer, metabolic and regulatory processes, DNA synthesis and repair and protein structure stabilization. Fe-S clusters are synthesized mainly in the mitochondrion, where they are directly incorporated into mitochondrial Fe-S cluster-containing proteins or exported for cytoplasmic and nuclear cluster-protein assembly. In this study, we tested the hypothesis that inhibition of mitochondrial complex I by rotenone decreases Fe-S cluster synthesis and cluster content and activity of Fe-S cluster-containing enzymes. Inhibition of complex I resulted in decreased activity of three Fe-S cluster-containing enzymes: mitochondrial and cytosolic aconitases and xanthine oxidase. In addition, the Fe-S cluster content of glutamine phosphoribosyl pyrophosphate amidotransferase and mitochondrial aconitase was dramatically decreased. The reduction in cytosolic aconitase activity was associated with an increase in iron regulatory protein (IRP) mRNA binding activity and with an increase in the cytoplasmic labile iron pool. Since IRP activity post-transcriptionally regulates the expression of iron import proteins, Fe-S cluster inhibition may result in a false iron deficiency signal. Given that

  7. Effect of mitochondrial complex I inhibition on Fe-S cluster protein activity

    International Nuclear Information System (INIS)

    Mena, Natalia P.; Bulteau, Anne Laure; Salazar, Julio; Hirsch, Etienne C.; Nunez, Marco T.

    2011-01-01

    Highlights: → Mitochondrial complex I inhibition resulted in decreased activity of Fe-S containing enzymes mitochondrial aconitase and cytoplasmic aconitase and xanthine oxidase. → Complex I inhibition resulted in the loss of Fe-S clusters in cytoplasmic aconitase and of glutamine phosphoribosyl pyrophosphate amidotransferase. → Consistent with loss of cytoplasmic aconitase activity, an increase in iron regulatory protein 1 activity was found. → Complex I inhibition resulted in an increase in the labile cytoplasmic iron pool. -- Abstract: Iron-sulfur (Fe-S) clusters are small inorganic cofactors formed by tetrahedral coordination of iron atoms with sulfur groups. Present in numerous proteins, these clusters are involved in key biological processes such as electron transfer, metabolic and regulatory processes, DNA synthesis and repair and protein structure stabilization. Fe-S clusters are synthesized mainly in the mitochondrion, where they are directly incorporated into mitochondrial Fe-S cluster-containing proteins or exported for cytoplasmic and nuclear cluster-protein assembly. In this study, we tested the hypothesis that inhibition of mitochondrial complex I by rotenone decreases Fe-S cluster synthesis and cluster content and activity of Fe-S cluster-containing enzymes. Inhibition of complex I resulted in decreased activity of three Fe-S cluster-containing enzymes: mitochondrial and cytosolic aconitases and xanthine oxidase. In addition, the Fe-S cluster content of glutamine phosphoribosyl pyrophosphate amidotransferase and mitochondrial aconitase was dramatically decreased. The reduction in cytosolic aconitase activity was associated with an increase in iron regulatory protein (IRP) mRNA binding activity and with an increase in the cytoplasmic labile iron pool. Since IRP activity post-transcriptionally regulates the expression of iron import proteins, Fe-S cluster inhibition may result in a false iron deficiency signal. Given that inhibition of complex

  8. Experimental research on the dynamic behaviors of the keyhole and molten pool in laser deep-penetration welding

    Science.gov (United States)

    Zhang, Yi; Lin, Qida; Yin, Xuni; Li, Simeng; Deng, Jiquan

    2018-04-01

    Both the morphology and temperature are two important characteristics of the keyhole and the molten pool in laser deep-penetration welding. The modified ‘sandwich’ method was adopted to overcome the difficulty in obtaining inner information about the keyhole and the molten pool. Based on this method, experimental platforms were built for observing the variations in the surface morphology, the longitudinal keyhole profile and the internal temperature. The experimental results of three dynamic behaviors exbibit as follows. The key factor, which makes the pool width go into a quasi-steady state, lies in the balance between the vortex and the sideways flows around the keyhole. Experimental observation shows that the keyhole goes through three stages in laser welding: the rapid drilling stage, the slow drilling stage and the quasi-steady state. The time for achieving a relative fixed keyhole depth is close to the formation time of the maximum pool width. The internal temperatures inside the keyhole and the molten pool first experience a rapid increase, then a decrease and finally go into a quasi-steady state. Compared to that in the unstable stage, the liquid–metal uphill formed in the stable stage of laser welding has less influence on the internal temperature.

  9. Allocation of Transportation Cost & CO2 Emission in Pooled Supply Chains Using Cooperative Game Theory

    OpenAIRE

    Xiaozhou Xu; Shenle Pan; Eric Ballot

    2012-01-01

    International audience; The sustainability of supply chain,both economical and ecological, has attracted intensive attentions of academic and industry. It is proven in former works that supply chain pooling given by horizontal cooperation among several independent supply chains create a new common supply chain network that could reduce the costs and the transport CO2 emissions. In this regard, this paper introduces a scheme to share in a fairly manner the savings. After a summary of the conce...

  10. Technical specification for fabrication of HANARO pool cover

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Woo, Sang Ik

    2001-06-01

    This technical specification details the requirements and the acceptance criteria for design, seismic analysis, function test, installation and quality assurance for HANARO pool cover which will be installed at the top of reactor pool. The pool cover is classified as non-nuclear safety, seismic category II and quality class T. The basic design of the pool cover for increasing HANARO applications has been carried out for supporting the driving devices which can load, unload and rotate the irradiation targets in the in-core and out-core vertical irradiation holes under on-power operation. The comments of HANARO user group related with irradiation tests have optimally considered in the process of design. The interference between fuel handling and control absorber units in the reactor pool and activities to load, unload and rotate the irradiation targets at the top of the reactor pool have been minimized. The pool cover can be moved for maintenance and can protect the reactor pool from unexpected drop of foreign materials. It provides the space to vertical access of driving devices for NTD, CT/IR and OR4/OR5 under on-power operation. And the pool cover assembly must maintain its structural integrity under seismic load. Based on the above design concept, the HANARO pool cover has been proposed as supporting structure of driving devices for NTD, fission moly and RI production under on-power operation.

  11. Soil carbon pools in different pasture systems

    Directory of Open Access Journals (Sweden)

    Francisco M. Cardozo, Jr.

    2016-03-01

    Full Text Available The aim of this study was to assess the carbon pools of a tropical soil where the native forest was replaced with different pasture systems. We studied five pasture production systems, including four monoculture systems with forage grasses such as Andropogon, Brachiaria, Panicum, and Cynodon, and an agroforestry system as well as a native vegetation plot. Greater availability of fulvic acid was detected in the agroforestry system as compared with that in the other systems. Higher lability of C was detected in the Andropogon system during the dry and rainy seasons and during the dry season in Cynodon. During the dry season, all pastures systems showed deficits in the net removal of atmospheric CO2. The structure and practices of the agroforestry system enables more carbon to be sequestered in the soil as compared with the monoculture pasture, suggesting that it is an important practice to mitigate climatic change and to improve soil quality.

  12. Corrosion surveillance in spent fuel storage pools

    International Nuclear Information System (INIS)

    Howell, J.P.

    1996-01-01

    In mid-1991, corrosion of aluminum-clad spent nuclear fuel was observed in the light-water filled basins at the Savannah River site. A corrosion surveillance program was initiated in the P, K, L-Reactor basins and in the Receiving Basin for Offsite Fuels (RBOF). This program verified the aggressive nature of the pitting corrosion and provided recommendations for changes in basin operations to permit extended longer term interim storage. The changes were implemented during 1994--1996 and have resulted in significantly improved basin water quality with conductivity in the 1--3 microS/cm range. Under these improved conditions, no new pitting has been observed over the last three years. This paper describes the corrosion surveillance program at SRS and what has been learned about the corrosion of aluminum-clad in spent fuel storage pools

  13. One knowledge base or many knowledge pools?

    DEFF Research Database (Denmark)

    Lundvall, Bengt-Åke

    It is increasingly realized that knowledge is the most important resource and that learning is the most important process in the economy. Sometimes this is expressed by coining the current era as characterised by a ‘knowledge based economy'. But this concept might be misleading by indicating...... that there is one common knowledge base on which economic activities can be built. In this paper we argue that it is more appropriate to see the economy as connecting to different ‘pools of knowledge'. The argument is built upon a conceptual framework where we make distinctions between private/public, local....../global, individual/collective and tacit/codified knowledge. The purpose is both ‘academic' and practical. Our analysis demonstrates the limits of a narrowly economic perspective on knowledge and we show that these distinctions have important implications both for innovation policy and for management of innovation....

  14. Photoelectrochemical Performance Observed in Mn-Doped BiFeO3 Heterostructured Thin Films

    Directory of Open Access Journals (Sweden)

    Hao-Min Xu

    2016-11-01

    Full Text Available Pure BiFeO3 and heterostructured BiFeO3/BiFe0.95Mn0.05O3 (5% Mn-doped BiFeO3 thin films have been prepared by a chemical deposition method. The band structures and photosensitive properties of these films have been investigated elaborately. Pure BiFeO3 films showed stable and strong response to photo illumination (open circuit potential kept −0.18 V, short circuit photocurrent density was −0.023 mA·cm−2. By Mn doping, the energy band positions shifted, resulting in a smaller band gap of BiFe0.95Mn0.05O3 layer and an internal field being built in the BiFeO3/BiFe0.95Mn0.05O3 interface. BiFeO3/BiFe0.95Mn0.05O3 and BiFe0.95Mn0.05O3 thin films demonstrated poor photo activity compared with pure BiFeO3 films, which can be explained by the fact that Mn doping brought in a large amount of defects in the BiFe0.95Mn0.05O3 layers, causing higher carrier combination and correspondingly suppressing the photo response, and this negative influence was more considerable than the positive effects provided by the band modulation.

  15. Santa Fe Accelerator Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The 10th USA National Particle Accelerator Conference was hosted this year by the Los Alamos National Laboratory in Santa Fe from 21-23 March. It was a resounding success in emphasizing the ferment of activity in the accelerator field. About 900 people registered and about 500 papers were presented in invited and contributed talks and poster sessions

  16. Santa Fe Linac Conference

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The 1981 Linear Accelerator Conference, organized by Los Alamos National Laboratory, was held from 19-23 October in Santa Fe, New Mexico. The surroundings were superb and helped to ensure a successful meeting. There were more than two hundred and twenty participants, with good representation from Japan and Western Europe

  17. Indoor swimming pools. Humidity caused problems and suggested solutions

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Reports have been received from across Canada on premature deterioration and other problems of indoor swimming pool buildings. This technical paper has been prepared to assist pool managers to solve these problems, which typically include leaking roofs, condensation on inside walls, peeling paint, efflorescence, rusting of metal elements, deterioration of concrete block structures, and high costs for pool heating. An effective insulation and vapor barrier system for a swimming pool roof is described, and the high relative humidity of the typical pool building is discussed as the primary cause of most problems. Proper sealing to cut down air infiltration is recommended, along with proper maintenance and painting. High energy costs are often due to low insulation values and to excessive ventilation used for decreasing the humidity. By using dehumidifiers capable of heat recovery, and by placing an insulating blanket on the pool after operating hours, it is shown that substantial cost savings are possible. 10 figs.

  18. Sharing as risk pooling in a social dilemma experiment

    Directory of Open Access Journals (Sweden)

    Todd L. Cherry

    2015-03-01

    Full Text Available In rural economies with missing or incomplete markets, idiosyncratic risk is frequently pooled through informal networks. Idiosyncratic shocks, however, are not limited to private goods but can also restrict an individual from partaking in or benefiting from a collective activity. In these situations, a group must decide whether to provide insurance to the affected member. We describe results of a laboratory experiment designed to test whether a simple sharing institution can sustain risk pooling in a social dilemma with idiosyncratic risk. We tested whether risk could be pooled without a commitment device and, separately, whether effective risk pooling induced greater cooperation in the social dilemma. We found that even in the absence of a commitment device or reputational considerations, subjects voluntarily pooled risk, thereby reducing variance in individual earnings. In spite of effective risk pooling, however, cooperation in the social dilemma was unaffected.

  19. Assessment of fuel damage of pool type research reactor in the case of fuel plates blockage

    Energy Technology Data Exchange (ETDEWEB)

    Jalil, Jafari; Samad, Khakshournia [AEOI, Karegar Ave. School of R and D of Nuclear Reactors and Accelerators, Teheran (Iran, Islamic Republic of); D' Auria, F. [Pisa Univ., DIMNP (Italy)

    2007-07-01

    Tehran Research Reactor (TRR) is a pool type 5 MW research reactor. It is assumed that external objects or debris that may fall down to reactor core cause obstruction of coolant flow through one of the fuel assemblies. Thermal hydraulic analysis of this event, using the RELAP5 system code has been studied. The reported transient is related to the partial and total obstruction of a single Fuel Element (FE) cooling channel of 27 FE equilibrium core of TRR. Such event constitutes a severe accident for this type of reactor since it may lead to local dryout and eventually to loss of the FE integrity. Two scenarios are analysed to emphasize the severity of the accident. The first one is a partial blockage of an average FE considering four different obstruction levels: 25%, 50%, 75% and 97% of nominal flow area. The second one is an extreme scenario consisting of total blockage of the same FE. This study constitutes the first step of a larger work which consists of performing a 3-dimensional simulation using the Best Estimate coupled code technique. However, as a first approach the instantaneous reactor power is derived through the point kinetic calculation included in the RELAP5 code. Main results obtained from the RELAP5 calculations are as following. First, in the case of flow blockage under 97% of the nominal flow area of an average FE, only an increase of the coolant and clad temperatures is observed without any consequences for the integrity of the FE. The mass flow rate remains sufficient to cool the clad safely. Secondly, in the case of total obstruction of the nominal flow area, it is seen that transient turns out to be a severe accident due to the dryout conditions are reached shortly and melting of the cladding occurs. Thirdly, the use of the point kinetic approach leads to conservative results. A best estimate simulation of such kind of transients requires the use of 3-dimensional kinetic calculations, which could be done using the current Coupled Codes

  20. The burning and smoke release rates of sodium pool fires

    International Nuclear Information System (INIS)

    Newman, R.N.; Payne, J.F.B.

    1976-10-01

    The burning rates and smoke release fractions of sodium pool fires have been measured over the pool temperature range 250 0 C to 750 0 C. A theoretical model is derived which satisfactorily predicts the burning rate over the above temperature range. The theory further predicts that the burning rate should be independent of pool diameter, a prediction supported by a comparison of burning rate data from this study and available data from other studies. (author)

  1. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  2. Reserve growth in oil pools of Alberta : model and forecast

    Energy Technology Data Exchange (ETDEWEB)

    Verma, M.; Cook, T. [United States Geological Survey, Denver, CO (United States). Central Region

    2010-09-15

    This paper presented a reserve growth study that was conducted on oil pools in Alberta, Canada. Historical oil reserve data were evaluated to assess the potential for future reserve growth in both pools and fields, and reserve growth models and functions were developed to better forecast hydrocarbon volumes. The study also considered the sensitivity of reserve growth to such factors as pool size, porosity, and oil gravity. From 1960 to 2005, the reported known recoverable oil in Alberta, excluding the Athabasca oil sands and including only pools with adequate data, increased from 4.2 to 13.9 billion barrels of oil (BBO). New discoveries contributed 3.7 BBO and reserve growth added 6 BBO. Most reserve growth occurred in pools with more than 125,000 barrels of oil. Light-oil pools account for most of the total known oil volume and consequently showed the lowest growth. Pools with greater than 30 percent porosity grew more than pools with lower porosity reservoirs. Oil field growth was found to be almost twice that of pool growth, possibly because the analysis evaluated fields with two or more pools discovered in different years. The growth in oil volumes in Alberta pools is projected to be about 454 million barrels of oil in the period from 2006 to 2010. Over a 25-year period, the cumulative reserve growth in Alberta oil pools was substantially lower than other major petroleum-producing regions, but the growth at the field level compares well. 8 refs., 2 tabs., 9 figs.

  3. Thermodynamical properties of 56Fe

    International Nuclear Information System (INIS)

    Tavukcu, E.; Becker, J. A.; Bernstein, L. A.; Garrett, P. E.; Younes, W.; Guttormsen, M.; Rekstad, J.; Siem, S.; Mitchell, G. E.; Schiller, A.; Voinov, A.

    2003-01-01

    Average nuclear level densities close to the nuclear binding energy in 56Fe and 57Fe are extracted from primary γ-ray spectra. A step structure is observed in the level density for both isotopes, and is interpreted as breaking of Cooper pairs. Thermal properties of 56Fe are studied within the statistical canonical ensemble. The experimental heat capacity in 56Fe is compared with the theoretical heat capacity calculated within the shell model Monte Carlo approach

  4. (Microbiological studies of small hot-bath-pools and hot-whirl-pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Exner, M; Havenith, N

    1981-01-01

    Hot small bathing pools and hot whirl-pools have the following characteristics: small watervolume, thick squeeze of swimmers, high water temperature (37-40 degrees C) and small dimension of filters. By this, the quality of bathing-water is influenced detrimentally. To elaborate the hygienic problems, bathing-water samples were taken before, during and after the visiting-hours and were tested for facultative-pathogenic microorganisms. During this investigation E. coli was isolated in 25 degrees, Coliforms and Proteus species in 37.3%, P. aeruginosa in 36%, S. aureus in 26.3%, Enterococci in 42.3 %, Candida albicans in 3.6% and yeast totally in 8.3%.

  5. The atmospheric wet pool: definition and comparison with the oceanic warm pool

    Institute of Scientific and Technical Information of China (English)

    ZHANG Caiyun; CHEN Ge

    2008-01-01

    The oceanic warm pool (OWP) defined by sea surface temperature (SST) is known as the "heat reservoir" in the ocean. The warmest portion in the ocean mirrors the fact that the wettest region with the largest accumulation of water vapor (WV) in the atmosphere, termed atmospheric wet pool (AWP), should be identified because of the well-known Clausius-Clapeyron relationship between SST and WV. In this study, we used 14-year simultaneous observations of WV and SST from January 1988 to December 2001 to define the AWP and investigate its coupling and co-variations with the OWP. The joint examination of the area variations, centroid locations, and zonal migrations of the AWP and OWP lead to a number of interesting findings. The results hopefully can contribute to our understanding of the air-sea interaction in general and characterization of El Nifio/La Nina events in particular.

  6. Patent pool analysis based on technical standards: A case study of indigenous alliances in China

    Directory of Open Access Journals (Sweden)

    DUAN Yuzhen

    2013-07-01

    Full Text Available China has set up only two sorts of patent pools (PLs with technical standards, namely, the AVS alliance and IGRS alliance. Both PLs are applied in the IT industry. Statistics of patent alliances with global technical standards show that Chinese enterprises cannot easily form and develop an international PL. This study analyzes the formation process of the AVS and IGRS patent alliance, and points out the challenges in building and developing Chinese PL. The study offers suggestions on alliance management, government guidance, and international cooperation.

  7. A Double Evolutionary Pool Memetic Algorithm for Examination Timetabling Problems

    Directory of Open Access Journals (Sweden)

    Yu Lei

    2014-01-01

    Full Text Available A double evolutionary pool memetic algorithm is proposed to solve the examination timetabling problem. To improve the performance of the proposed algorithm, two evolutionary pools, that is, the main evolutionary pool and the secondary evolutionary pool, are employed. The genetic operators have been specially designed to fit the examination timetabling problem. A simplified version of the simulated annealing strategy is designed to speed the convergence of the algorithm. A clonal mechanism is introduced to preserve population diversity. Extensive experiments carried out on 12 benchmark examination timetabling instances show that the proposed algorithm is able to produce promising results for the uncapacitated examination timetabling problem.

  8. Crust formation and its effect on the molten pool coolability

    Energy Technology Data Exchange (ETDEWEB)

    Park, R.J.; Lee, S.J.; Sim, S.K. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-09-01

    Experimental and analytical studies of the crust formation and its effect on the molten pool coolability have been performed to examine the crust formation process as a function of boundary temperatures as well as to investigate heat transfer characteristics between molten pool and overlying water in order to evaluate coolability of the molten pool. The experimental test results have shown that the surface temperature of the bottom plate is a dominant parameter in the crust formation process of the molten pool. It is also found that the crust thickness of the case with direct coolant injection into the molten pool is greater than that of the case with a heat exchanger. Increasing mass flow rate of direct coolant injection to the molten pool does not affect the temperature of molten pool after the crust has been formed in the molten pool because the crust behaves as a thermal barrier. The Nusselt number between the molten pool and the coolant of the case with no crust formation is greater than that of the case with crust formation. The results of FLOW-3D analyses have shown that the temperature distribution contributes to the crust formation process due to Rayleigh-Benard natural convection flow.

  9. Automated management of engineering infrastructure of pools of different purpose

    Directory of Open Access Journals (Sweden)

    Shirokov Lev Alekseevich

    2016-10-01

    Full Text Available Pools play an important role in people’s life. They answer people’s demand in rest and improve their health. At the same time pools are rather important for industrial use, for example in construction industry. In order to solve different construction problems it is essential to investigate the influence of microclimatic parameters on construction materials and structures. For this aim pools are in demand as special test sites for construction materials and structures in different environmental conditions including the case of a direct water impact. The efficient use of pools presupposes the necessity of constant hydroclimatic contro: air humidity and temperature, water temperature, chemical composition of water and air. Classification of pools of different purposes is presented in the article. The author considers the main problems of operation of pools as objects with complicated air-and-water environment. The questions of maintaining optimal microclimatic parameters in a pool are considered. The necessity of use of the control system of a microclimate, its efficiency, profitability and social effect of its implementation is described. A mathematical model of the thermal mode of a pool area is constructed. The process of indoor temperature regulation in the pool is considered.

  10. Steam blowdown experiments with the condensation pool test rig

    International Nuclear Information System (INIS)

    Purhonen, H.; Puustinen, M.; Laine, J.; Raesaenen, A.; Kyrki-Rajamaeki, R.; Vihavainen, J.

    2005-01-01

    During a possible loss-of-coolant accident (Local) a large amount of non-condensable (nitrogen) and condensable (steam) gas is blown from the upper drywell of the containment to the condensation pool through the blowdown pipes at the boiling water reactors (BWRs). The wet well pool serves as the major heat sink for condensation of steam. The blowdown causes both dynamic and structural loads to the condensation pool. There might also be a risk that the gas discharging to the pool could push its way to the emergency core cooling systems (ECCS) and undermine their performance. (author)

  11. Evaporation-preventive device for nuclear reactor pool water

    International Nuclear Information System (INIS)

    Kurusu, Yoshihisa; Akabori, Shiro.

    1986-01-01

    Purpose: To prevent pool water from evaporating by a great amount in a reactor pool such as a spent fuel storing pool. Constitution: Air discharge and in-take ports are disposed just above the surface of the pool water and charge and discharge of airs are forcively carried out to form air curtains above the pool water. Water vapor evaporated from the surface of the pool water does not diffuse above the air curtains due to the air stream of the curtains, but is intaken into the intake port and then condensated into water by a steam condensator and re-supplied to the pool. Since diffusion of water vapor and radioactive materials are suppressed above the air curtains, the working circumstance in the pool chamber can be maintained desirably thereby keeping the radioactivity dose in the atmosphere. Further, incorporation of dusts from above into the pool can also be prevented by the air curtains to provide an effect for the prevention of radioactive contamination. Further, since covers are not used, visual observation can be insured. (Kawakami, Y.)

  12. Evaporation rate measurement in the pool of IEAR-1 reactor

    International Nuclear Information System (INIS)

    Torres, Walmir Maximo; Cegalla, Miriam A.; Baptista Filho, Benedito Dias

    2000-01-01

    The surface water evaporation in pool type reactors affects the ventilation system operation and the ambient conditions and dose rates in the operation room. This paper shows the results of evaporation rate experiment in the pool of IEA-R1 research reactor. The experiment is based on the demineralized water mass variation inside cylindrical metallic recipients during a time interval. Other parameters were measured, such as: barometric pressure, relative humidity, environmental temperature, water temperature inside the recipients and water temperature in the reactor pool. The pool level variation due to water contraction/expansion was calculated. (author)

  13. Livestock Grazing as a Driver of Vernal Pool Ecohydrology

    Science.gov (United States)

    Michaels, J.; McCarten, N. F.

    2017-12-01

    Vernal pools are seasonal wetlands that host rare plant communities of high conservation priority. Plant community composition is largely driven by pool hydroperiod. A previous study found that vernal pools grazed by livestock had longer hydroperiods compared with pools excluded from grazing for 10 years, and suggests that livestock grazing can be used to protect plant diversity. It is important to assess whether observed differences are due to the grazing or due to water balance variables including upland discharge into or out of the pools since no a priori measurements were made of the hydrology prior to grazing. To address this question, in 2016 we compared 15 pools that have been grazed continuously and 15 pools that have been fenced off for over 40 years at a site in Sacramento County. We paired pools based on abiotic characteristics (size, shape, slope, soil type) to minimize natural variation. We sampled vegetation and water depth using Solinst level loggers. We found that plant diversity and average hydroperiod was significantly higher in the grazed pools. We are currently measuring groundwater connectivity and upland inputs in order to compare the relative strength of livestock grazing as a driver of hydroperiod to these other drivers.

  14. Diffusion of Nb in Fe and in some Fe alloys

    International Nuclear Information System (INIS)

    Kurokawa, S.; Ruzzante, J.E.; Hey, A.M.; Dyment, F.

    1981-01-01

    Diffusion data of microalloying elements such as Nb, V, Ti, are required when analysing the transformation and recrystallization behaviour of HSLA steels in order to optimize grain refinement and precipitation hardening. The diffusion behaviour of Nb in pure Fe, Fe 1.5 Mn, Fe 0.6 Si and Fe 1.5 Mn 0.6 Si has been measured between 1080 and 1200 0 C. Results indicate that Si increases Nb diffusivity while Mn decreases it. The sequence of diffusion coeficients values is: D sup(Nb) sub(Fe 1.5 Mn) [pt

  15. Thermodynamical Properties of 56Fe

    International Nuclear Information System (INIS)

    Tavukcu, E.; Becker, J.A.; Bernstein, L.A.; Garrett, P.E.; Guttormsen, M.; Mitchell, G.E.; Rekstad, J.; Schiller, A.; Siem, S.; Voinov, A.; Younes, W.

    2002-01-01

    Average nuclear level densities close to the nuclear binding energy in 56 Fe and 57 Fe are extracted from primary γ-ray spectra. Thermal properties of 56 Fe are studied within the statistical canonical ensemble. The experimental heat capacity is compared with the theoretical heat capacity calculated within the shell model Monte Carlo approach

  16. Natural convection heat transfer in a rectangular pool with volumetric heat sources

    International Nuclear Information System (INIS)

    Lee, Seung Dong; Lee, Kang Hee; Suh, Kune Y.

    2003-01-01

    Natural convection plays an important role in determining the thermal load from debris accumulated in the reactor vessel lower head during a severe accident. The heat transfer within the molten core material can be characterized by buoyancy-induced flows resulting from internal heating due to decay of fission products. The thermo-fluid dynamic characteristics of the molten pool depend strongly on the thermal boundary conditions. The spatial and temporal variation of heat flux on the pool wall boundaries and the pool superheat are mainly characterized by the natural convection flow inside the molten pool. In general, natural convection involving internal heat generation is delineated in terms of the modified Rayleigh number, Ra', which quantifies the internal heat source and hence the strength of buoyancy. The test section is of rectangular cavity whose length, width, and height are 500 mm, 80 mm, and 250 mm, respectively. A total of twenty-four T-type thermocouples were installed in the test loop to measure temperature distribution. Four T-type thermocouples were utilized to measure temperatures on the boundary. A direct heating method was adopted in this test to simulate the uniform heat generation. The experiments covered a range of Rayleigh number, Ra, between 4.87x10 7 and 2.32x10 14 and Prandtl number, Pr, between 0.7 and 3.98. Tests were conducted with water and air as simulant. The upper and lower boundary conditions were maintained at a uniform temperature of 10degC. (author)

  17. 26 CFR 1.642(c)-6 - Valuation of a remainder interest in property transferred to a pooled income fund.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Valuation of a remainder interest in property... § 1.642(c)-6 Valuation of a remainder interest in property transferred to a pooled income fund. (a) In... transferred property on the valuation date. The fact that the income beneficiary may not receive the last...

  18. Total quality in spent fuel pool reracking

    International Nuclear Information System (INIS)

    Cranston, J.S.; Bradbury, R.B.; Cacciapouti, R.J.

    1993-01-01

    The nuclear utility environment is one of strict cost control under prescriptive regulations and increasing public scrutiny. This paper presents the results of A Total Quality approach, by a dedicated team, that addresses the need for increased on-site spent fuel storage in this environment. Innovations to spent fuel pool reracking, driven by utilities' specific technical needs and shrinking budgets, have resulted in both product improvements and lower prices. A Total Quality approach to the entire turnkey project is taken, thereby creating synergism and process efficiency in each of the major phases of the project: design and analysis, licensing, fabrication, installation and disposal. Specific technical advances and the proven quality of the team members minimizes risk to the utility and its shareholders and provides a complete, cost effective service. Proper evaluation of spent fuel storage methods and vendors requires a full understanding of currently available customer driven initiatives that reduce cost while improving quality. In all phases of a spent fuel reracking project, from new rack design and analysis through old rack disposal, the integration of diverse experts, at all levels and throughout all phases of a reracking project, better serves utility needs. This Total Quality environment in conjunction with many technical improvements results in a higher quality product at a lower cost

  19. Positive year for Alberta power pool

    International Nuclear Information System (INIS)

    Reid-Carlson, D.

    1997-01-01

    The electricity power pool in Alberta completed its first year under deregulation. Results to date indicate that the competitive market has operated as intended. The effects of electricity pricing on the oil industry following deregulation were described, given the fact that electricity prices represent the second largest cost item to the oil industry after labour. The peculiarities of the mechanism of electricity pricing (based on hourly matching of supply offers to demand bids) were explained, highlighting the opportunities and risks to the oil industry caused by the hourly price variations and the difficulties involved in accurately forecasting on-peak and off-peak prices a full year in advance. In 1996 predicted average price was $14 to $17/MWh. The actual average price was $13.40/MWh. The general conclusion was that Alberta continues to have a surplus of electricity generation and is well positioned to to take advantage of its low generating costs, at least over the longer term. Short term bidding practices, however, may results in slightly higher system marginal prices

  20. Pool critical assembly pressure vessel facility benchmark

    International Nuclear Information System (INIS)

    Remec, I.; Kam, F.B.K.

    1997-07-01

    This pool critical assembly (PCA) pressure vessel wall facility benchmark (PCA benchmark) is described and analyzed in this report. Analysis of the PCA benchmark can be used for partial fulfillment of the requirements for the qualification of the methodology for pressure vessel neutron fluence calculations, as required by the US Nuclear Regulatory Commission regulatory guide DG-1053. Section 1 of this report describes the PCA benchmark and provides all data necessary for the benchmark analysis. The measured quantities, to be compared with the calculated values, are the equivalent fission fluxes. In Section 2 the analysis of the PCA benchmark is described. Calculations with the computer code DORT, based on the discrete-ordinates method, were performed for three ENDF/B-VI-based multigroup libraries: BUGLE-93, SAILOR-95, and BUGLE-96. An excellent agreement of the calculated (C) and measures (M) equivalent fission fluxes was obtained. The arithmetic average C/M for all the dosimeters (total of 31) was 0.93 ± 0.03 and 0.92 ± 0.03 for the SAILOR-95 and BUGLE-96 libraries, respectively. The average C/M ratio, obtained with the BUGLE-93 library, for the 28 measurements was 0.93 ± 0.03 (the neptunium measurements in the water and air regions were overpredicted and excluded from the average). No systematic decrease in the C/M ratios with increasing distance from the core was observed for any of the libraries used

  1. Iodine release from sodium pool combustion

    International Nuclear Information System (INIS)

    Sagawa, N.; Fukushima, Y.; Yokota, N.; Akagane, K.; Mochizuki, K.

    1979-01-01

    Iodine release associated with sodium pool combustion was determined by heating 20 gr sodium containing sodium iodide, which was labelled with 131 I and dissolved in the sodium in concentration of 1∼1,000 ppm, to burn on a nickel crucible in conditioned atmosphere in a closed vessel of 0.4 m 3 . Oxygen concentration was changed in 5∼21% and humidity in 0∼89% by mixing nitrogen gas and air. Combustion products were trapped by a Maypack filter composed of particle filters, copper screens and activated charcoal beds and by a glass beads pack cooled by liquid argon. Iodine collected on these filter elements was determined by radio-gas chromatography. When the sodium sample burned in the atmosphere of air at room temperature, the release fractions observed were 6∼33% for sodium and 1∼20% for iodine added in the sodium. The release iodine was present in aerosol at a ratio of 98%, and the remainder in the gas form. The release fraction of iodine trended to decrease as oxygen concentration and humidity in the atmosphere increased. No organic iodide was detected in the combustion products. (author)

  2. Spent fuel pool risk analysis for the Dukovany NPP

    Energy Technology Data Exchange (ETDEWEB)

    Hust' ak, S.; Jaros, M.; Kubicek, J. [UJV Rez, a.s., Husinec-Rez (Czech Republic)

    2013-07-01

    UJV Rez, a.s. maintains a Living Probabilistic Safety Assessment (Living PSA) program for Dukovany Nuclear Power Plant (NPP) in the Czech Republic. This project has been established as a framework for activities related to risk assessment and to support for risk-informed decision making at this plant. The most extensively used PSA application at Dukovany NPP is risk monitoring of instantaneous (point-in-time) risk during plant operation, especially for the purpose of configuration risk management during plant scheduled outages to avoid risk significant configurations. The scope of PSA for Dukovany NPP includes also determination of a risk contribution from spent fuel pool (SFP) operation to provide recommendations for the prevention and mitigation of SFP accidents and to be applicable for configuration risk management. This paper describes the analysis of internal initiating events (IEs) in PSA for Dukovany NPP, which can contribute to the risk from SFP operation. The analysis of those IEs was done more thoroughly in the PSA for Dukovany NPP in order to be used in instantaneous risk monitoring. (orig.)

  3. Penetration of a heated pool into a melting miscible substrate

    International Nuclear Information System (INIS)

    Eck, G.; Werle, H.

    1986-01-01

    Core-catchers have been proposed, which, after a core disruptive accident in a nuclear reactor, prevent containment failure caused by contact of the molten debris with the underlying ex-vessel structural materials. Most of these core-catchers are provided with sacrificial layers which on melting consume some fraction of the decay heat and dilute the heat sources and the fissionable material as the core masses are dissolved by the molten sacrificial material. Dilution of the core masses results in relatively low heat fluxes and temperatures at the wall of the core-catcher and, in addition, reduces the probability of recriticality. An experimental study was conducted on melting systems consisting of a liquid over-lying a solid substrate, which after melting of the solid, are mutually miscible. To initiate melting, the liquid was heated either by a planar heater from above or internally by an ac current. The density of the liquid was varied systematically, and it was found that downward heat transfer increases strongly with this parameter. In addition to heat transfer, mass transfer was studied by measuring the local concentration of the molten material in the liquid. A few experiments were performed in which sideward melting and two-dimensional pool growth were investigated

  4. Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool

    Energy Technology Data Exchange (ETDEWEB)

    Woolley, Jonathan; Harrington, Curtis; Modera, Mark [University of California Davis, Western Cooling Efficiency Center, 1450 Drew Avenue, Suite 100, Davis, CA 95618 (United States)

    2011-01-15

    Swimming pools as thermal sinks for air conditioners could save approximately 40% on peak cooling power and 30% of overall cooling energy, compared to standard residential air conditioning. Heat dissipation from pools in semi-arid climates with large diurnal temperature shifts is such that pool heating and space cooling may occur concurrently; in which case heat rejected from cooling equipment could directly displace pool heating energy, while also improving space cooling efficiency. The performance of such a system relies on the natural temperature regulation of swimming pools governed by evaporative and convective heat exchange with the air, radiative heat exchange with the sky, and conductive heat exchange with the ground. This paper describes and validates a model that uses meteorological data to accurately predict the hourly temperature of a swimming pool to within 1.1 C maximum error over the period of observation. A thorough review of literature guided our choice of the most appropriate set of equations to describe the natural mass and energy exchange between a swimming pool and the environment. Monitoring of a pool in Davis, CA, was used to confirm the resulting simulations. Comparison of predicted and observed pool temperature for all hours over a 56 day experimental period shows an R-squared relatedness of 0.967. (author)

  5. Macroinvertebrate community assembly in pools created during peatland restoration.

    Science.gov (United States)

    Brown, Lee E; Ramchunder, Sorain J; Beadle, Jeannie M; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  6. MFM study of NdFeB and NdFeB/Fe/NdFeB thin films

    International Nuclear Information System (INIS)

    Gouteff, P.C.; Folks, L.; Street, R.

    1998-01-01

    Domain structures of NdFeB thin films, ranging in thickness between 1500 and 29 nm, have been studied qualitatively by magnetic force microscopy (MFM). Samples were prepared using a range of sputtering conditions resulting in differences in properties such as texture, coercivity and magnetic saturation. MFM images of all the films showed extensive interaction domain structures, similar to those observed in nanocrystalline bulk NdFeB. An exchange-coupled NdFeB/Fe/NdFeB trilayer with layer thicknesses 18 nm/15 nm/18 nm, respectively, was also examined using MFM. (orig.)

  7. 76 FR 72923 - Pool Corporation; Analysis To Aid Public Comment

    Science.gov (United States)

    2011-11-28

    ... manufacturers, warehouse them, and then resell the products to pool retail stores, pool service companies and.... ADDRESSES: Interested parties may file a comment online or on paper, by following the instructions in the... 0115'' on your comment, and file your comment online at https://ftcpublic.commentworks.com/ftc...

  8. Solar collectors for swimming pools still going strong

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    According to the opinion of the experts, solar energy heating may be technically 'mature' but the profitability is by no means that far. However, solar systems are a good alternative for heating the water in swimming pools. Four solar collector systems developed by different firms to heat swimming pools, including prices, are presented.

  9. Microscopic bubble behaviour in suppression pool during wetwell venting

    Science.gov (United States)

    Zablackaite, G.; Nagasaka, H.; Kikura, H.

    2017-10-01

    During a severe accident PCV failure should be avoided and fission products inside PCV should be confined as much as possible. In order to minimize FPs release, Wetwell venting is conducted by releasing steam-non-condensable gas mixture carrying FPs from the Drywell to Suppression Pool. Steam is condensed by subcooled water in the pool, and most of FPs are retained into water. The removal of FP in the water pool is referred to as “Pool Scrubbing effect”. Hydrodynamic parameters of bubbles have impact on pool scrubbing effect. However, there is only few data available to evaluate quantitatively the bubble behaviour under depressurization and/or thermal stratification conditions. Series of experiments were conducted to evaluate the influence of temperature distribution, non-condensable gas content and pressure in the Wetwell on bubble behaviour. Bubbles were visualized using High Speed Camera and adopting shadowgraphy technique. Applying Particle Tracking Velocimetry, bubble velocity and size distribution were obtained from recorded images. Experimental results show that with increasing suppression pool temperature, bubbles reaching the pool surface decreased in size and traveling velocity became slower. In pressurized wetwell, bubble behaviour was similar to that in the heated up suppression pool case, although bubble parameters were similar to the low temperature case. Higher air content induced water surface movement and bubbles were smaller due to break up.

  10. 48 CFR 28.304 - Risk-pooling arrangements.

    Science.gov (United States)

    2010-10-01

    ... CONTRACTING REQUIREMENTS BONDS AND INSURANCE Insurance 28.304 Risk-pooling arrangements. Agencies may establish risk-pooling arrangements. These arrangements are designed to use the services of the insurance industry for safety engineering and the handling of claims at minimum cost to the Government. The agency...

  11. Biomass and carbon pools of disturbed riparian forests

    Science.gov (United States)

    Laura A. B. Giese; W. M. Aust; Randall K. Kolka; Carl C. Trettin

    2003-01-01

    Quantification of carbon pools as affected by forest age/development can facilitate riparian restoration and increase awareness of the potential for forests to sequester global carbon. Riparian forest biomass and carbon pools were quantified for four riparian forests representing different seral stages in the South Carolina Upper Coastal Plain. Three of the riparian...

  12. 17 CFR 275.206(4)-8 - Pooled investment vehicles.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Pooled investment vehicles... COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT ADVISERS ACT OF 1940 § 275.206(4)-8 Pooled investment vehicles. (a) Prohibition. It shall constitute a fraudulent, deceptive, or manipulative act...

  13. Mathematical-programming approaches to test item pool design

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; van der Linden, Willem J.; Ariel, A.

    2002-01-01

    This paper presents an approach to item pool design that has the potential to improve on the quality of current item pools in educational and psychological testing andhence to increase both measurement precision and validity. The approach consists of the application of mathematical programming

  14. Anticipated corrosion in the Vermont Yankee spent fuel pool

    International Nuclear Information System (INIS)

    Weeks, J.R.

    1977-06-01

    The report provides additional information relating to a proposed modification to the spent fuel pool at the Vermont Yankee Nuclear Power Station (VYNPS) and addresses corrosion of spent fuel pool storage materials and zircaloy, and provides an analysis of the effectiveness of the Boral sealing

  15. Numerical analysis of weld pool oscillation in laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ho [Chungbuk National University, Cheongju (Korea, Republic of); Farson, Dave F [The Ohio State University, Columbus (United States); Hollis, Kendall; Milewski, John O. [Los Alamos National Laboratory, Los Alamos (United States)

    2015-04-15

    Volume of fluid (VOF) numerical simulation was used to investigate melt flow and volumetric oscillation of conduction-mode pulsed laser weld pools. The result is compared to high speed video stream of titanium laser spot welding experiment. The total simulation time is 10ms with the first 5 ms being heating and melting under constant laser irradiation and the remaining 5 ms corresponding to resolidification of the weld pool. During the melting process, the liquid pool did not exhibit periodic oscillation but was continually depressed by the evaporation recoil pressure. After the laser pulse, the weld pool was excited into volumetric oscillation by the release of pressure on its surface and oscillation of the weld pool surface was analyzed. The simulation model suggested adjusting thermal diffusivity to match cooling rate and puddle diameter during solidification which is distinguishable from previous weld pool simulation. The frequency continuously increased from several thousand cycles per second to tens of thousands of cycles per second as the weld pool solidified and its diameter decreased. The result is the first trial of investigation of small weld pool oscillation in laser welding although there have been several reports about arc welding.

  16. 13 CFR 120.1709 - Transfers of Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Transfers of Pool Certificates. 120.1709 Section 120.1709 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1709...

  17. 13 CFR 120.1714 - Seller's Pool Loan servicing.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan servicing. 120.1714 Section 120.1714 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1714 Seller...

  18. 13 CFR 120.1715 - Seller's Pool Loan liquidation.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan liquidation. 120.1715 Section 120.1715 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1715 Seller...

  19. 13 CFR 120.1713 - Seller's Pool Loan origination.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan origination. 120.1713 Section 120.1713 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1713 Seller...

  20. 13 CFR 120.1717 - Seller's Pool Loan deferments.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan deferments. 120.1717 Section 120.1717 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1717 Seller...

  1. AUS burnup module CHAR and the associated data pool

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1975-12-01

    The CHAR module of the AUS reactor neutronics scheme solves the multiregion nuclide depletion equations using an analytic method. The module obtains cross section, flux and geometry data from AUS data pools, and uses the STATUS data pool which has been designed for the storage of nuclide compositions, spatial smearing factors and other miscellaneous information. (author)

  2. Phytomass carbon pool of trees and forests in India

    NARCIS (Netherlands)

    Kaul, M.; Mohren, G.M.J.; Dadhwal, V.K.

    2011-01-01

    The study reports estimates of above ground phytomass carbon pools in Indian forests for 1992 and 2002 using two different methodologies. The first estimate was derived from remote sensing based forest area and crown density estimates, and growing stock data for 1992 and 2002 and the estimated pool

  3. Odonata (Insecta at a wadi Pool near Nizwa, northern Oman

    Directory of Open Access Journals (Sweden)

    Elaine M. Cowan

    2015-07-01

    Full Text Available Fourteen damselfly and dragonfly species were recorded in 68 visits to a wadi pool in northern Oman, March 2012 to June 2014.  All identifications were based on photographs.  Apparently the pool has a core community of eight resident species.  Paragomphus sinaiticus, globally Near Threatened, was regularly  recorded. 

  4. Branchipodopsis species — specialists of ephemeral rock pools ...

    African Journals Online (AJOL)

    Such rock pools were studied in the Drakensberg region, in the eastern Free State and in south-eastern Botswana. Common features ... While short-range dispersal of floating eggs by overflows is common, long-range dispersal (e.g. by wind) seems to be rare and to be restricted to shallow pools with little vegetation. Limited ...

  5. Characteristics of fission product release from a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    The volatile fission products are released from the debris pool, while the less volatile fission products tend to remain as condensed phases because of their low vapor pressure. The release of noble gases and the volatile fission products is dominated by bubble dynamics. The release of the less volatile fission products from the pool can be analyzed based on mass transport through a liquid with the convection flow. The physico-numerical models were orchestrated from existing submodels in various disciplines of engineering to estimate the released fraction of fission products from a molten pool. It was assumed that the pool has partially filled hemispherical geometry. For the high pool pressure, the diameter of the bubbles at detachment was calculated utilizing the Cole and Shulman correlation with the effect of system pressure. Sensitivity analyses were performed and results of the numerical calculations were compared with analysis results for the TMI-2 accident. (author)

  6. Tax credits and purchasing pools: will this marriage work?

    Science.gov (United States)

    Trude, S; Ginsburg, P B

    2001-04-01

    Bipartisan interest is growing in Congress for using federal tax credits to help low-income families buy health insurance. Regardless of the approach taken, tax credit policies must address risk selection issues to ensure coverage for the chronically ill. Proposals that link tax credits to purchasing pools would avoid risk selection by grouping risks similar to the way large employers do. Voluntary purchasing pools have had only limited success, however. This Issue Brief discusses linking tax credits to purchasing pools. It uses information from the Center for Studying Health System Change's (HSC) site visits to 12 communities as well as other research to assess the role of purchasing pools nationwide and the key issues and implications of linking tax credits and pools.

  7. Controlling pool depth during VAR of Alloy 718

    Science.gov (United States)

    Lopez, F.; Beaman, J.; Williamson, R.; Evans, D.

    2016-07-01

    A longtime goal of superalloy producers has been to control the geometry of the liquid pool in solidifying ingots. Accurate pool depth control at appropriate values is expected to result in ingots free of segregation defects. This article describes an industrial VAR experiment in which a 430mm (17 in) diameter Alloy 718 electrode was melted into a 510mm (20 in) ingot. In the experiment, the depth of the liquid pool at the mid-radius was controlled to three different set-points: 137 mm (nominal), 193 mm (deep) and 118 mm (shallow). At each level, the pool depth was marked by a power cutback of several minutes. The ingot was sectioned and longitudinal slices were cut out. Analysis of the photographed ingot revealed that accurate control was obtained for both the nominal and deep pool cases, while the third one was not conclusive.

  8. High field Moessbauer and magnetic investigations of Pr0.73Fe4Sb12

    International Nuclear Information System (INIS)

    Reissner, Michael; Bauer, Ernst; Steiner, Walter; Rogl, Peter

    2004-01-01

    In accordance with the filling factor determined by X-ray investigations two Fe sites were identified in the in-field 57 Fe Moessbauer spectra. The derived internal fields at 4.2 K were small (0.35 and 1.45 T at external fields of 13.5 T), whereas from magnetic measurements μ eff ∼2.7 μ B was estimated for the Fe 4 Sb 12 -sublattice

  9. Preliminary results of the US pool-boiling coils from the IFSMTF full-array tests

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.; Lubell, M.S.; Luton, J.N.; McManamy, T.J.; Shen, S.S.

    1986-01-01

    The Large Coil Task to develop superconducting magnets for fusion reactors, is now in the midst of full-array tests in the International Fusion Superconducting Magnet Test Facility at Oak Ridge National Laboratory. Included in the test array are two pool-boiling coils designed and fabricated by US manufacturers, General Dynamics/Convair Division and General Electric/Union Carbide Corporation. So far, both coils have been energized to full design currents in the single-coil tests, and the General Dynamics coil has reached the design point in the first Standard-I full-array test. Both coils performed well in the charging experiments. Extensive heating tests and the heavy instrumentation of these coils have, however, revealed some generic limitations of large pool-boiling superconducting coils. Details of these results and their analyses are reported

  10. Corrosion of aluminium alloy test coupons in water of spent fuel storage pool at RA reactor

    International Nuclear Information System (INIS)

    Pesic, M.; Maksin, T.; Jordanov, G.; Dobrijevic, R.

    2004-12-01

    Study on corrosion of aluminium cladding, of the TVR-S type of enriched uranium spent fuel elements of the research reactor RA in the storage water pool is examined in the framework nr the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) 'Corrosion of Research Reactor Clad-Clad Spent Fuel in Water' since 2002. Standard racks with aluminium coupons are exposed to water in the spent fuel pools of the research reactor RA. After predetermined exposure times along with periodic monitoring of the water parameters, the coupons are examined according to the strategy and the protocol supplied by the IAEA. Description of the standard corrosion racks, experimental protocols, test procedures, water quality monitoring and compilation of results of visual examination of corrosion effects are present in this article. (author)

  11. Pooling Data from Multiple Longitudinal Studies: The Role of Item Response Theory in Integrative Data Analysis

    Science.gov (United States)

    Curran, Patrick J.; Hussong, Andrea M.; Cai, Li; Huang, Wenjing; Chassin, Laurie; Sher, Kenneth J.; Zucker, Robert A.

    2010-01-01

    There are a number of significant challenges encountered when studying development over an extended period of time including subject attrition, changing measurement structures across group and developmental period, and the need to invest substantial time and money. Integrative data analysis is an emerging set of methodologies that overcomes many of the challenges of single sample designs through the pooling of data drawn from multiple existing developmental studies. This approach is characterized by a host of advantages, but this also introduces several new complexities that must be addressed prior to broad adoption by developmental researchers. In this paper we focus on methods for fitting measurement models and creating scale scores using data drawn from multiple longitudinal studies. We present findings from the analysis of repeated measures of internalizing symptomatology that were pooled from three existing developmental studies. We describe and demonstrate each step in the analysis and we conclude with a discussion of potential limitations and directions for future research. PMID:18331129

  12. International Trade. International Business

    OpenAIRE

    Мохнюк, А. М.; Mokhniuk, A. M.

    2015-01-01

    Work programme of the study course “International Trade. International Business” was prepared in accordance with educational and vocational training program for bachelors of training direction 6.030601 “Management”.

  13. A Heat Transfer Model for a Stratified Corium-Metal Pool in the Lower Plenum of a Nuclear Reactor

    International Nuclear Information System (INIS)

    Sohal, M.S.; Siefken, L.J.

    1999-01-01

    This preliminary design report describes a model for heat transfer in a corium-metal stratified pool. It was decided to make use of the existing COUPLE model. Currently available correlations for natural convection heat transfer in a pool with and without internal heat generation were obtained. The appropriate correlations will be incorporated in the existing COUPLE model. Heat conduction and solidification modeling will be done with existing algorithms in the COUPLE. Assessment of the new model will be done by simple energy conservation problems

  14. 3-D numerical simulation on the vibration of liquid sodium's free surface in sodium pool of FBR

    International Nuclear Information System (INIS)

    Han Biao; Yao Zhaohui; Ye Hongkai; Wang Xuefang

    1997-01-01

    This paper succeeds in simulating three-dimensional incompressible flows with free surface, complicated in-flow and out-flow boundary conditions and internal obstacles, and also can treat these fluid flows in arbitrary shape vessel using a partial cell. According to all kinds of the element influencing the free surface's vibration in sodium pool it may give the various wave's form, the highest and lowest position, and the amount of the vibration. This paper introduces the brief principle of VOF numerical method, develops the computational program based on NASA-VOF3D, provides some results about the free surface's vibration in sodium pool of FBR

  15. Framing water and forests as global or local? Transnational community-based networks transforming common-pool resources essence and scales

    OpenAIRE

    Dupuits, Emilie; Pflieger, Géraldine

    2017-01-01

    The current era of globalization and commodification has had a substantial impact on common-pool resources governance. In direct response to this, community-based organizations managing water and forests at the local level began to create their own transnational networks. Primarily, these organizations aim to achieve direct representation in international decision-making arenas in order to promote their model of collective governance. By reframing the representations of common-pool resources ...

  16. Safety analysis of LWR irradiated fuel element pool storages before reprocessing

    International Nuclear Information System (INIS)

    Lefort, G.; Leclerc, J.; Hoffman, A.; Frejaville, C.; Domage, M.

    1984-01-01

    The protection of operators and environment requires imperatively that the safety must be taken into account as early as the design of the pools takes place and working conditions are defined. The analysis of criticality, irradiation, contamination, external or internal aggression hazards... allows to draw the main constraints which must be retained in the sizing of these pools: the criticality risk needs distances between fuel elements which results in a not very good utilization of the available area which leads to the utilization of neutron shieldings or requires a safe knowledge of the fuel elements burn up; the irradiation and contamination risks require a special quality of the pool water (temperature, activity, purity...) a good tightness of the basins to locate and to isolate the dubions fuel elements; the external or internal aggression risks such as earthquakes, missiles or loads drops, explosion, imply the civil engineering and involve the use of special technical devices. A brief presentation of the pool storages of the next UP2-800 and UP3 A reprocessing plants allows to show how the requirement drawn by safety analysis have been enforced, while carrying out civil engineering works without equivalent in the world, in this field. The foreseeable evolution of the uranium enrichment rate and burn-up of next PWR fuel elements have an effect upon the risk evaluations; a device apparatus, developed in CEA, for the measurement of burn up and cooling time is presented. At least, a short presentation of the mechanical structure durability studies of the reception and storage spent fuels installations are allowed to improve our knowledge in working conditions and in case of serious accidents

  17. poolHiTS: A Shifted Transversal Design based pooling strategy for high-throughput drug screening

    Directory of Open Access Journals (Sweden)

    Woolf Peter J

    2008-05-01

    Full Text Available Abstract Background A key goal of drug discovery is to increase the throughput of small molecule screens without sacrificing screening accuracy. High-throughput screening (HTS in drug discovery involves testing a large number of compounds in a biological assay to identify active compounds. Normally, molecules from a large compound library are tested individually to identify the activity of each molecule. Usually a small number of compounds are found to be active, however the presence of false positive and negative testing errors suggests that this one-drug one-assay screening strategy can be significantly improved. Pooling designs are testing schemes that test mixtures of compounds in each assay, thereby generating a screen of the whole compound library in fewer tests. By repeatedly testing compounds in different combinations, pooling designs also allow for error-correction. These pooled designs, for specific experiment parameters, can be simply and efficiently created using the Shifted Transversal Design (STD pooling algorithm. However, drug screening contains a number of key constraints that require specific modifications if this pooling approach is to be useful for practical screen designs. Results In this paper, we introduce a pooling strategy called poolHiTS (Pooled High-Throughput Screening which is based on the STD algorithm. In poolHiTS, we implement a limit on the number of compounds that can be mixed in a single assay. In addition, we show that the STD-based pooling strategy is limited in the error-correction that it can achieve. Due to the mixing constraint, we show that it is more efficient to split a large library into smaller blocks of compounds, which are then tested using an optimized strategy repeated for each block. We package the optimal block selection algorithm into poolHiTS. The MATLAB codes for the poolHiTS algorithm and the corresponding decoding strategy are also provided. Conclusion We have produced a practical version

  18. How oxygen attacks [FeFe] hydrogenases from photosynthetic organisms

    Science.gov (United States)

    Stripp, Sven T.; Goldet, Gabrielle; Brandmayr, Caterina; Sanganas, Oliver; Vincent, Kylie A.; Haumann, Michael; Armstrong, Fraser A.; Happe, Thomas

    2009-01-01

    Green algae such as Chlamydomonas reinhardtii synthesize an [FeFe] hydrogenase that is highly active in hydrogen evolution. However, the extreme sensitivity of [FeFe] hydrogenases to oxygen presents a major challenge for exploiting these organisms to achieve sustainable photosynthetic hydrogen production. In this study, the mechanism of oxygen inactivation of the [FeFe] hydrogenase CrHydA1 from C. reinhardtii has been investigated. X-ray absorption spectroscopy shows that reaction with oxygen results in destruction of the [4Fe-4S] domain of the active site H-cluster while leaving the di-iron domain (2FeH) essentially intact. By protein film electrochemistry we were able to determine the order of events leading up to this destruction. Carbon monoxide, a competitive inhibitor of CrHydA1 which binds to an Fe atom of the 2FeH domain and is otherwise not known to attack FeS clusters in proteins, reacts nearly two orders of magnitude faster than oxygen and protects the enzyme against oxygen damage. These results therefore show that destruction of the [4Fe-4S] cluster is initiated by binding and reduction of oxygen at the di-iron domain—a key step that is blocked by carbon monoxide. The relatively slow attack by oxygen compared to carbon monoxide suggests that a very high level of discrimination can be achieved by subtle factors such as electronic effects (specific orbital overlap requirements) and steric constraints at the active site. PMID:19805068

  19. Nuclear insurance in the future Internal Market

    International Nuclear Information System (INIS)

    Mueller-Stein, J.

    1991-01-01

    Summarizing, it is prognosticated that nuclear insurance practice will not drastically change on account of the Internal Market. This assumption is based on the unanimous estimation of the nuclear energy risk by the international insurance industry, as is documented by their traditional good cooperation in pools. (orig.) [de

  20. NUTRIENTS POOL IN CONSORTIA OF Eucalyptus urograndis, Acacia mearnsii AND Zea mays

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2013-08-01

    Full Text Available http://dx.doi.org/10.5902/1980509810543This study aimed to determine the nutrient pool in monospecific and mixed stands of Eucalyptus urograndis and Acacia mearnsii in a consortium with Zea mays.The amount determination of nutrients of forest species was carried out in the treatments: 100E (100% of eucalyptus; 100A (100% of black wattle and 50E:50A (50% of eucalyptus + 50% of black-wattle. On the other hand, for corn, it was carried out in all treatments (100E; 100A, 50E:50A; 75E:25A – 75% of eucalyptus + 25% black-wattle and 25E:75A – 25% of eucalyptus + 75% of black wattle. The delimitation adopted was the one of a randomized block with three replications. The magnitude of the nutrient pool in the agrossilvicultural systems biomass was: N> K > Ca > Mg > P > S, for macronutrients, and Mn > Fe > Zn > B > Cu, for micronutrients. Due to the great export of nutrients through the corn harvest, residues should be kept and it is necessary to make a nutritional reposition, mainly with P, N, K, S and Zn in the following crops, because of the higher amount that are exported with the extraction of the corn tang, which reaches 75.3; 60.6; 59.9; 55.8 e 53.8%, respectively, in relation to the total stocked in the biomass.

  1. Neutralized wettability effect of superhydrophilic Cr-layered surface on pool boiling critical heat flux

    International Nuclear Information System (INIS)

    Son, Hong Hyun; Jeong, Ui Ju; Seo, Gwang Hyeok; Jeun, Gyoo Dong; Kim, Sung Joong

    2016-01-01

    The former method is deemed challenging due to longer development period and license issue. In this regard, FeCrAl, Cr, and SiC have been received positive attention as ATF coating materials because they are highly resistant to high temperature steam reaction causing massive hydrogen generation. In this study, Cr was selected as a target deposition material on the metal substrate because we found that Cr-layered surface becomes superhydrophilic, favorable to delaying the triggering of the critical heat flux (CHF). Thus in order to investigate the effect of Cr-layered superhydrophilic surfaces (under explored coating conditions) on pool boiling heat transfer, pool boiling experiment was conducted in the saturated deionized water under atmospheric pressure. As a physical vapor deposition (PVD) method, the DC magnetron sputtering technique was introduced to develop Cr-layered nanostructure. As a control variable of DC sputtering, substrate temperature was selected. Surface wettability and nanostructure were analyzed as major surface parameters on the CHF. We believe that highly dense micro/nano structure without nucleation cavities and inner pores neutralized the wettability effect on the CHF. Moreover, superhydrophilic surface with deficient cavity density rather hinders active nucleation. This emphasizes the importance of micro/nano structure surface for enhanced boiling heat transfer.

  2. A Mechanistic Model of Waterfall Plunge Pool Erosion into Bedrock

    Science.gov (United States)

    Scheingross, Joel S.; Lamb, Michael P.

    2017-11-01

    Landscapes often respond to changes in climate and tectonics through the formation and upstream propagation of knickzones composed of waterfalls. Little work has been done on the mechanics of waterfall erosion, and instead most landscape-scale models neglect waterfalls or use rules for river erosion, such as stream power, that may not be applicable to waterfalls. Here we develop a physically based model to predict waterfall plunge pool erosion into rock by abrasion from particle impacts and test the model against flume experiments. Both the model and experiments show that evolving plunge pools have initially high vertical erosion rates due to energetic particle impacts, and erosion slows and eventually ceases as pools deepen and deposition protects the pool floor from further erosion. Lateral erosion can continue after deposition on the pool floor, but it occurs at slow rates that become negligible as pools widen. Our work points to the importance of vertical drilling of successive plunge pools to drive upstream knickzone propagation in homogenous rock, rather than the classic mechanism of headwall undercutting. For a series of vertically drilling waterfalls, we find that upstream knickzone propagation is faster under higher combined water and sediment fluxes and for knickzones composed of many waterfalls that are closely spaced. Our model differs significantly from stream-power-based erosion rules in that steeper knickzones can retreat faster or more slowly depending on the number and spacing of waterfalls within a knickzone, which has implications for interpreting climatic and tectonic history through analysis of river longitudinal profiles.

  3. Addressing data privacy in matched studies via virtual pooling.

    Science.gov (United States)

    Saha-Chaudhuri, P; Weinberg, C R

    2017-09-07

    Data confidentiality and shared use of research data are two desirable but sometimes conflicting goals in research with multi-center studies and distributed data. While ideal for straightforward analysis, confidentiality restrictions forbid creation of a single dataset that includes covariate information of all participants. Current approaches such as aggregate data sharing, distributed regression, meta-analysis and score-based methods can have important limitations. We propose a novel application of an existing epidemiologic tool, specimen pooling, to enable confidentiality-preserving analysis of data arising from a matched case-control, multi-center design. Instead of pooling specimens prior to assay, we apply the methodology to virtually pool (aggregate) covariates within nodes. Such virtual pooling retains most of the information used in an analysis with individual data and since individual participant data is not shared externally, within-node virtual pooling preserves data confidentiality. We show that aggregated covariate levels can be used in a conditional logistic regression model to estimate individual-level odds ratios of interest. The parameter estimates from the standard conditional logistic regression are compared to the estimates based on a conditional logistic regression model with aggregated data. The parameter estimates are shown to be similar to those without pooling and to have comparable standard errors and confidence interval coverage. Virtual data pooling can be used to maintain confidentiality of data from multi-center study and can be particularly useful in research with large-scale distributed data.

  4. Preliminary Calculation on a Spent Fuel Pool Accident using GOTHIC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaehwan; Choi, Yu Jung; Hong, Tae Hyub; Kim, Hyeong-Taek [KHNP-CRI, Daejeon (Korea, Republic of)

    2015-10-15

    The probability of an accident happening at the spent fuel pool was believed to be quite low until the 2011 Fukushima accident occurred. Notably, large amount of spent fuel are normally stored in the spent fuel pool for a long time compared to the amount of fuel in the reactor core and the total heat released from the spent fuel is high enough to boil the water of the spent fuel pool when the cooling system does not operate. In addition, the enrichment and the burnup of the fuel have both increased in the past decade and heat generation from the spent fuel thereby has also increased. The failure of the cooling system at the spent fuel pool (hereafter, a loss-of-cooling accident) is one of the principal hypothetical causes of an accident that could occur at the spent fuel pool. In this paper, the preliminary calculation of a loss-of-cooling accident was performed. In this paper, the preliminary calculation of a loss-of cooling accident was performed with GOTHIC. The calculation results show boiling away of water in the spent fuel pool due to the loss-of-cooling accident and similar thermal performance of the spent fuel pool with previous research results.

  5. 3D finite element simulation of TIG weld pool

    Science.gov (United States)

    Kong, X.; Asserin, O.; Gounand, S.; Gilles, P.; Bergheau, J. M.; Medale, M.

    2012-07-01

    The aim of this paper is to propose a three-dimensional weld pool model for the moving gas tungsten arc welding (GTAW) process, in order to understand the main factors that limit the weld quality and improve the productivity, especially with respect to the welding speed. Simulation is a very powerful tool to help in understanding the physical phenomena in the weld process. A 3D finite element model of heat and fluid flow in weld pool considering free surface of the pool and traveling speed has been developed for the GTAW process. Cast3M software is used to compute all the governing equations. The free surface of the weld pool is calculated by minimizing the total surface energy. The combined effects of surface tension gradient, buoyancy force, arc pressure, arc drag force to drive the fluid flow is included in our model. The deformation of the weld pool surface and the welding speed affect fluid flow, heat flow and thus temperature gradients and molten pool dimensions. Welding trials study is presented to compare our numerical results with macrograph of the molten pool.

  6. Study on water evaporation rate from indoor swimming pools

    Directory of Open Access Journals (Sweden)

    Rzeźnik Ilona

    2017-01-01

    Full Text Available The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C and recreational swimming pool (water temperature 34°C. According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.

  7. Security cost allocation under combined bilateral-pool market dispatch

    International Nuclear Information System (INIS)

    Abdullah, M.P.; Hassan, M.Y.; Hussin, F.

    2008-01-01

    Most electricity markets around the world are a combination of bilateral and pool markets, such as NordPool and NYPOOL. In these models, market participants bid into the pool and also make bilateral contracts with each other. This paper addressed the issue of congestion management and security cost allocation in a power pool market model. The basic idea of security cost allocation is to divide the incurred security cost due to congestion relief into pool and bilateral market based on their flow contribution to the congested line. A newly proposed security cost allocation strategy of the combined bilateral-pool market was also presented along with case studies using IEEE-14 bus system that tested the proposed method. Using the proposed method, it was shown that security costs are allocated to market participants at different prices which reflect the load contribution to the security problem. This solves the problem of the uniform security cost allocation in a pure pool market system having uniform pricing, and provides a proper security signal to market participants. 11 refs., 3 tabs., 4 figs

  8. Loss of spent fuel pool cooling PRA: Model and results

    International Nuclear Information System (INIS)

    Siu, N.; Khericha, S.; Conroy, S.; Beck, S.; Blackman, H.

    1996-09-01

    This letter report documents models for quantifying the likelihood of loss of spent fuel pool cooling; models for identifying post-boiling scenarios that lead to core damage; qualitative and quantitative results generated for a selected plant that account for plant design and operational practices; a comparison of these results and those generated from earlier studies; and a review of available data on spent fuel pool accidents. The results of this study show that for a representative two-unit boiling water reactor, the annual probability of spent fuel pool boiling is 5 x 10 -5 and the annual probability of flooding associated with loss of spent fuel pool cooling scenarios is 1 x 10 -3 . Qualitative arguments are provided to show that the likelihood of core damage due to spent fuel pool boiling accidents is low for most US commercial nuclear power plants. It is also shown that, depending on the design characteristics of a given plant, the likelihood of either: (a) core damage due to spent fuel pool-associated flooding, or (b) spent fuel damage due to pool dryout, may not be negligible

  9. Study on velocity distribution in a pool by submersible mixers

    International Nuclear Information System (INIS)

    Tian, F; Shi, W D; Lu, X N; Chen, B; Jiang, H

    2012-01-01

    To study the distribution of submersible mixers and agitating effect in the sewage treatment pool, Pro/E software was utilized to build the three-dimensional model. Then, the large-scale computational fluid dynamics software FLUENT6.3 was used. ICEM software was used to build unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. The macro fluid field and each section velocity flow field distribution were analyzed to observe the efficiency of each submersible mixer. The average velocity and mixing area in the sewage pool were studied simultaneously. Results show that: the preferred project B, two submersible mixers speed is 980 r/min, and setting angles are all 30°. Fluid mixing area in the pool has reached more than 95%. Under the action of two mixers, the fluid in the sewage pool form a continuous circulating water flow. The fluid is mixed adequately and average velocity of fluid in the pool is at around 0.241m/s, which agreed with the work requirements. Consequently it can provide a reference basis for practical engineering application of submersible mixers by using this method.

  10. Mathematical modeling of the energy consumption of heated swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Le Bel, C.; Millette, J. [LTE Shawinigan, Shawinigan, PQ (Canada)

    2007-07-01

    A mathematical model was developed to estimate the water temperature of a residential swimming pool. The model can compare 2 different situations and, if local climatic conditions are known, it can accurately predict energy costs of the pool relative to the total energy consumption of the house. When used with the appropriate energy transfer coefficient and weather file, the model can estimate the water temperature of a residential swimming pool having specific characteristics, such as in-ground, above-ground, heated or non-heated. The model is suitable for determining residential loads. It can be applied to different pool types and sizes, for different water heating scenarios and different climatic regions. Data obtained from the monitoring of water temperature and electricity use of 57 residential swimming pools was used to validate the model. In addition, 5 above-ground pools were installed on the property of LTE Shawinigan to allow for a more detailed study of the parameters involved in the thermal balance of a pool. The mathematical model, based on a global heat transfer coefficient, can determine the effect of a solar blanket and the effect of water volume. 14 refs., 5 tabs., 11 figs.

  11. Fe de Erratas

    Directory of Open Access Journals (Sweden)

    Perspectiva Geográfica

    2014-01-01

    Full Text Available La Magíster Sonia Jimena Murillo Munar, autora del artículo titulado “Transporte urbano sostenible: medidas desde la administración y transporte público como alternativa en Bogotá”, publicado en el Volumen No. 13 correspondiente al año 2008, solicita la inclusión de la siguiente FE DE ERRATAS con la enmienda de un error de exclusiva responsabilidad del Equipo Editorial de la Revista.

  12. Structure and magnetism in Co/X, Fe/Si, and Fe/(FeSi) multilayers

    Science.gov (United States)

    Franklin, Michael Ray

    Previous studies have shown that magnetic behavior in multilayers formed by repeating a bilayer unit comprised of a ferromagnetic layer and a non-magnetic spacer layer can be affected by small structural differences. For example, a macroscopic property such as giant magnetoresistance (GMR) is believed to depend significantly upon interfacial roughness. In this study, several complimentary structural probes were used to carefully characterize the structure of several sputtered multilayer systems-Co/Ag, Co/Cu, Co/Mo, Fe/Si, and Fe//[FeSi/]. X-ray diffraction (XRD) studies were used to examine the long-range structural order of the multilayers perpendicular to the plane of the layers. Transmission electron diffraction (TED) studies were used to probe the long-range order parallel to the layer plane. X-ray Absorption Fine Structure (XAFS) studies were used to determine the average local structural environment of the ferromagnetic atoms. For the Co/X systems, a simple correlation between crystal structure and saturation magnetization is discovered for the Co/Mo system. For the Fe/X systems, direct evidence of an Fe-silicide is found for the /[FeSi/] spacer layer but not for the Si spacer layer. Additionally, differences were observed in the magnetic behavior between the Fe in the nominally pure Fe layer and the Fe contained in the /[FeSi/] spacer layers.

  13. ENERGY SAVING AT OPERATION OF OUTDOOR SWIMMING POOLS

    Directory of Open Access Journals (Sweden)

    V. F. Ivin

    2013-09-01

    Full Text Available Purpose. Energy saving is a major problem in modern power engineering and various energy-consuming devices. They include outdoor swimming pools. In order to maintain them in working condition, especially in winter period, it takes significant amount of thermal energy. Task of heat loss substantial decrease in open swimming pools is considered in the article (on DNURT example. Methodology. The method of determining the mass and heat loss on the basis of criteria equations of heat and mass transfer theory is used. Findings. Calculations of the actual DNURT pool heat loss for different seasons, as for natural convection both for air forced motion above the free water surface are performed. It is shown that for the adiabatic evaporation conditions of water from the pool in winter during blow-off with wind the heat loss can be up to 2 kW/m2 on surface. To reduce these losses it is offered to cover water surface in a pool with a special material with low thermal conductivity on the basis of porous polyethylene during the time when the pool is not used for other purposes. It is shown that the implementation of these standards will reduce the actual heat loss, at least 5-6 times. Originality. The solution of important environmental and energy problem thanks to reducing heat losses by the pool in different times of a year and correspondingly lower emissions of power generating enterprises. Practical value. It is shown that the coating surface of the pool with poorly heat-conducting and easy to install coating will let, at a minimum, to reduce the actual heat loss on 5-6 times and reduce the emissions of power plants generating energy for pool heating.

  14. Flow dynamics of volume-heated boiling pools

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C.; Chen, J.C.

    1979-01-01

    Safety analyses of fast breeder reactors require understanding of the two-phase fluid dynamic and heat transfer characteristics of volume-heated boiling pool systems. Design of direct contact three-phase boilers, of practical interest in the chemical industries also requires understanding of the fundamental two-phase flow and heat transfer behavior of volume boiling systems. Several experiments have been recently reported relevant to the boundary heat-loss mechanisms of boiling pool systems. Considerably less is known about the two-phase fluid dynamic behavior of such systems. This paper describes an experimental investigation of the steady-state flow dynamics of volume-heated boiling pool systems

  15. Mitochondrial deoxyribonucleoside triphosphate pools in thymidine kinase 2 deficiency.

    Science.gov (United States)

    Saada, Ann; Ben-Shalom, Efrat; Zyslin, Rivka; Miller, Chaya; Mandel, Hanna; Elpeleg, Orly

    2003-10-24

    Deficiency of mitochondrial thymidine kinase (TK2) is associated with mitochondrial DNA (mtDNA) depletion and manifests by severe skeletal myopathy in infancy. In order to elucidate the pathophysiology of this condition, mitochondrial deoxyribonucleoside triphosphate (dNTP) pools were determined in patients' fibroblasts. Despite normal mtDNA content and cytochrome c oxidase (COX) activity, mitochondrial dNTP pools were imbalanced. Specifically, deoxythymidine triphosphate (dTTP) content was markedly decreased, resulting in reduced dTTP:deoxycytidine triphosphate ratio. These findings underline the importance of balanced mitochondrial dNTP pools for mtDNA synthesis and may serve as the basis for future therapeutic interventions.

  16. Non-electric applications of pool-type nuclear reactors

    International Nuclear Information System (INIS)

    Adamov, E.O.; Cherkashov, Yu.M.; Romenkov, A.A.

    1997-01-01

    This paper recommends the use of pool-type light water reactors for thermal energy production. Safety and reliability of these reactors were already demonstrated to the public by the long-term operation of swimming pool research reactors. The paper presents the design experience of two projects: Apatity Underground Nuclear Heating Plant and Nuclear Sea-Water Desalination Plant. The simplicity of pool-type reactors, the ease of their manufacturing and maintenance make this type of a heat source attractive to the countries without a developed nuclear industry. (author). 6 figs, 1 tab

  17. Macroinvertebrate community assembly in pools created during peatland restoration

    International Nuclear Information System (INIS)

    Brown, Lee E.; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-01-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  18. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  19. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  20. Macroinvertebrate community assembly in pools created during peatland restoration

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Lee E., E-mail: l.brown@leeds.ac.uk; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  1. Modeling of the Temperature Field Recovery in the Oil Pool

    Science.gov (United States)

    Khabibullin, I. L.; Davtetbaev, A. Ya.; Mar'in, D. F.; Khisamov, A. A.

    2018-05-01

    This paper considers the problem on mathematical modeling of the temperature field recovery in the oil pool upon termination of injection of water into the pool. The problem is broken down into two stages: injection of water and temperature and pressure recovery upon termination of injection. A review of the existing mathematical models is presented, analytical solutions for a number of cases have been constructed, and a comparison of the analytical solutions of different models has been made. In the general form, the expression has been obtained that permits determining the temperature change in the oil pool upon termination of injection of water (recovery of the temperature field).

  2. Core-concrete molten pool dynamics and interfacial heat transfer

    International Nuclear Information System (INIS)

    Benjamin, A.S.

    1980-01-01

    Theoretical models are derived for the heat transfer from molten oxide pools to an underlying concrete surface and from molten steel pools to a general concrete containment. To accomplish this, two separate effects models are first developed, one emphasizing the vigorous agitation of the molten pool by gases evolving from the concrete and the other considering the insulating effect of a slag layer produced by concrete melting. The resulting algebraic expressions, combined into a general core-concrete heat transfer representation, are shown to provide very good agreement with experiments involving molten steel pours into concrete crucibles

  3. Change in color of the hot spring deposits at the Chinoike-Jigoku hot pool, Beppu geothermal field

    Energy Technology Data Exchange (ETDEWEB)

    Kazuthoshi, Oue; Ohsawa, Shinji; Yusa, Yuki [Kyoto University, Beppu (Japan). Beppu Geothermal Research Laboratory, Graduate School of Science

    2002-06-01

    The Chinoike-Jigoku hot pool in Beppu geothermal field, Central Kyushu, Japan, displays a blood-red color due to the hematite (Fe{sub 2}O{sub 3}) deposited at the bottom of the pool. The colors of the deposits collected on 1 October 1990, on 27 March 1995, and on 6 March 1996 were measured with a colorimeter. The results show that the red deposits became yellower in 1995 and 1996 than they were in 1990. X-ray diffraction (XRD) patterns and chemical compositions of the deposits indicate that the discoloration of the Chinoike-Jigoku pool water is caused by an increase in the content of jarosite [KFe{sub 3}(SO{sub 4}){sub 2}(OH){sub 6}]. The temperature of the subsurface thermal water beneath the Chinoike-Jigoku hot pool, as estimated by the anhydrite chemical geothermometer, has declined from 200 to 150{sup o}C over the past 25 years. The Na and Cl concentrations of the hot spring water discharging from Chinoike-Jigoku have decreased, while the SO{sub 4} concentration has increased. The temporal variations in subsurface temperature and dissolved ion concentrations suggest that the mixing ratio between the high-temperature, neutral Na-Cl type water and the relatively low-temperature, acid H-SO{sub 4} type water that form the thermal water of Chinoike-Jigoku has changed over the last 25 years. Hydrothermal studies of jarosite stability have confirmed that the increase in jarosite content in the deposits was caused by a temperature drop of the mixed thermal water beneath Chinoike-Jigoku pool, due to an increase in the contribution of the cooler H-SO{sub 4} water type to the thermal mixture. (author)

  4. Imported malaria in pregnant women: a retrospective pooled analysis

    Science.gov (United States)

    Käser, Annina K.; Arguin, Paul M.; Chiodini, Peter L.; Smith, Valerie; Delmont, Jean; Jiménez, Beatriz C.; Färnert, Anna; Kimura, Mikio; Ramharter, Michael; Grobusch, Martin P.; Schlagenhauf, Patricia

    2015-01-01

    Summary Background Data on imported malaria in pregnant women are scarce. Method A retrospective, descriptive study of pooled data on imported malaria in pregnancy was done, using data from 1977 to 2014 from 8 different collaborators in Europe, the United States and Japan. Most cases were from the period 1991–2014. National malaria reference centresas well as specialists on this topic were asked to search their archives for cases of imported malaria in pregnancy. A total of 632 cases were collated, providing information on Plasmodium species, region of acquisition, nationality, country of residence, reason for travel, age, gestational age, prophylactic measures and treatment used, as well as on complications and outcomes in mother and child. Results Datasets from some sources were incomplete. The predominant Plasmodium species was P. falciparum in 72% of cases. Among the 543 cases where information on the use of chemoprophylaxis was known, 471 (74.5%) did not use chemoprophylaxis or used incorrect or incomplete chemoprophylaxis. The main reason for travelling was “visiting friends and relatives” VFR (48.6%) and overall, most cases of malaria were imported from West Africa (85.9%). Severe anaemia was the most frequent complication in the mother. Data on offspring outcome was limited, but spontaneous abortion was a frequently reported foetal outcome (n = 14). A total of 50 different variants of malaria treatment regimens were reported. Conclusion Imported cases of malaria in pregnancy are mainly P. falciparum acquired in sub-Saharan Africa. Malaria prevention and treatment in pregnant travellers is a challenge for travel medicine due to few data on medication safety and maternal and foetal outcomes. International, collaborative efforts are needed to capture standardized data on imported malaria cases in pregnant women. PMID:26227740

  5. Structural analysis of a reflux pool-boiler solar receiver

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, E.L.; Stone, C.M.

    1991-06-01

    Coupled thermal-structural finite element calculations of a reflux pool-boiler solar receiver were performed to characterize the operating stresses and to address issues affecting the service life of the receiver. Analyses performed using shell elements provided information for receiver material selection and design optimization. Calculations based on linear elastic fracture mechanics principles were performed using continuum elements to assess the vulnerability of a seam-weld to fatigue crack growth. All calculations were performed using ABAQUS, a general purpose finite element code, and elements specifically formulated for coupled thermal-structural analysis. Two materials were evaluated: 316L SS and Haynes 230 alloys. The receiver response was simulated for a combination of structural and thermal loads that represent the startup and operating conditions of the receiver. For both materials, maximum stresses in the receiver developed shortly after startup due to uneven temperature distribution across the receiver surface. The largest effective stress was near yield in the 316L SS receiver and below 39 percent of yield in the Haynes 230 receiver. The calculations demonstrated that stress reductions of over 25 percent could be obtained by reducing the aft dome thickness to one closer to the absorber. The fatigue calculations demonstrated that the stress distribution near the seam-weld notch depends primarily on the structural load created by internal pressurization of the receiver rather than the thermal, indicating that the thermal loads can be neglected when assessing the stress intensity near the seam-weld notch. The stress intensity factor, computed using the J-integral method and crack opening-displacement field equations, was significantly below the fatigue threshold for most steels. The calculations indicated that the weld notch was always loaded in compression, a condition which is not conducive to fatigue crack growth. 15 refs., 30 figs., 3 tabs.

  6. Retail Demand Response in Southwest Power Pool

    Energy Technology Data Exchange (ETDEWEB)

    Bharvirkar, Ranjit; Heffner, Grayson; Goldman, Charles

    2009-01-30

    In 2007, the Southwest Power Pool (SPP) formed the Customer Response Task Force (CRTF) to identify barriers to deploying demand response (DR) resources in wholesale markets and develop policies to overcome these barriers. One of the initiatives of this Task Force was to develop more detailed information on existing retail DR programs and dynamic pricing tariffs, program rules, and utility operating practices. This report describes the results of a comprehensive survey conducted by LBNL in support of the Customer Response Task Force and discusses policy implications for integrating legacy retail DR programs and dynamic pricing tariffs into wholesale markets in the SPP region. LBNL conducted a detailed survey of existing DR programs and dynamic pricing tariffs administered by SPP's member utilities. Survey respondents were asked to provide information on advance notice requirements to customers, operational triggers used to call events (e.g. system emergencies, market conditions, local emergencies), use of these DR resources to meet planning reserves requirements, DR resource availability (e.g. seasonal, annual), participant incentive structures, and monitoring and verification (M&V) protocols. Nearly all of the 30 load-serving entities in SPP responded to the survey. Of this group, fourteen SPP member utilities administer 36 DR programs, five dynamic pricing tariffs, and six voluntary customer response initiatives. These existing DR programs and dynamic pricing tariffs have a peak demand reduction potential of 1,552 MW. Other major findings of this study are: o About 81percent of available DR is from interruptible rate tariffs offered to large commercial and industrial customers, while direct load control (DLC) programs account for ~;;14percent. o Arkansas accounts for ~;;50percent of the DR resources in the SPP footprint; these DR resources are primarily managed by cooperatives. o Publicly-owned cooperatives accounted for 54percent of the existing DR resources

  7. Magnetic structure of molecular magnet Fe[Fe(CN) 6

    Indian Academy of Sciences (India)

    We have studied the magnetic structure of Fe[Fe(CN)6]·4H2O, prepared by precipitation method, using neutron diffraction technique. Temperature dependent DC magnetization study down to 4.2 K shows that the compound undergoes from a high temperature disordered (paramagnetic) to an ordered magnetic phase ...

  8. Utility of pooled urine specimens for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in men attending public sexually transmitted infection clinics in Mumbai, India, by PCR.

    Science.gov (United States)

    Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne

    2005-04-01

    Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.

  9. Pool Onistarist kuulub kütusefirma omanikele / Sirje Niitra

    Index Scriptorium Estoniae

    Niitra, Sirje, 1948-

    2001-01-01

    Alkoholikontserni Onistar kiiret tõusu Eesti alkoholiturul toetavad Vene rahvusest ärimeestele kuuluvate kütusefirmade Infast Oil ja Saurix Petroleum omanikud, kellele kuulub pool Eesti viinaturu liidri aktsiatest

  10. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included

  11. 41 CFR 101-25.109-2 - Equipment pools.

    Science.gov (United States)

    2010-07-01

    ... number and location of equipment pools, consideration shall be given to economy of operation, mobility of... available for sharing or loan. Information concerning the availability of this equipment can be maintained...

  12. Open Architecture, Inventory Pooling and Spare Maintenance Assets

    National Research Council Canada - National Science Library

    Ferrer, Geraldo

    2007-01-01

    .... This article focuses on the benefits provided by pooling together the inventory necessary to meet the demand of many users into a small number of storage sites with reduced product variety obtained...

  13. Investigation to radioactive contamination of pool water in IMEF

    International Nuclear Information System (INIS)

    Song, Ung Sup; Jung, Yang Hong; Lee, J. H.; Lee, H. K.

    2003-06-01

    The pool (3x6x10) in irradiated materials examination facility is usually used for the purpose of taking the specimen out of cask loaded into the pool, and carrying in/out the specimen to/ from the hot cell. Always, it must be cared for the water into the pool to be fine condition because all operation are worked with the naked eye during taking an irradiated materials out of the cask and plunging them in the bucket-elevator. In the aspects of the radioactive remained substances in the water must be controlled so that the amount of substances to be lower than the standard amount prescribed by RCA Korea Activity in a part of radioactive contamination control. In consequence, an expertness of status and a practical use of skill make possible the prevention of radioactive material's diffusion or the radioactive contamination of pool water and safety work

  14. Allegheny County Public Swimming Pool, Hot Tub, and Spa Inspections

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Public swimming pool, hot tub, and spa facilities are licensed and inspected once each year to assure proper water quality, sanitation, lifeguard coverage and...

  15. 17 CFR 229.1111 - (Item 1111) Pool assets.

    Science.gov (United States)

    2010-04-01

    ... information for the asset pool, including statistical information regarding delinquencies and losses. (d.... Present statistical information in tabular or graphical format, if such presentation will aid understanding. Present statistical information in appropriate distributional groups or incremental ranges in...

  16. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  17. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included.

  18. Condensation pool experiments with steam using DN200 blowdown pipe

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.

    2005-08-01

    This report summarizes the results of the condensation pool experiments with steam using a DN200 blowdown pipe. Altogether five experiment series, each consisting of several steam blows, were carried out in December 2004 with a scaled-down test facility designed and constructed at Lappeenranta University of Technology. The main purpose of the experiments was to increase the understanding of different phenomena in the condensation pool during steam discharge. (au)

  19. Optimization of spent fuel pool weir gate driving mechanism

    Science.gov (United States)

    Liu, Chao; Du, Lin; Tao, Xinlei; Wang, Shijie; Shang, Ertao; Yu, Jianjiang

    2018-04-01

    Spent fuel pool is crucial facility for fuel storage and nuclear safety, and the spent fuel pool weir gate is the key related equipment. In order to achieve a goal of more efficient driving force transfer, loading during the opening/closing process is analyzed and an optimized calculation method for dimensions of driving mechanism is proposed. The result of optimizing example shows that the method can be applied to weir gates' design with similar driving mechanism.

  20. CHARACTERISTICS OFBENTHIC FISH COMMUNITY OF DNIEPER STORAGE POOL LITTORAL ZONE

    Directory of Open Access Journals (Sweden)

    Novitskiy R. A.

    2011-11-01

    Full Text Available Specific composition of bull-calves is analyzed together with their quantitative and quality parameters in the littoral zone of the Dnepr storage pool. The structural-functional features of organization of littoral communities of bull-calves were studied. The patterns of spatial distribution of Bull-calf (Gobiidae representatives were analyzed for the storage pool; their role in the littoral fish communities was clarified.

  1. Research progresses and future directions on pool boiling heat transfer

    OpenAIRE

    M. Kumar; V. Bhutani; P. Khatak

    2015-01-01

    This paper reviews the previous work carried on pool boiling heat transfer during heating of various liquids and commodities categorized as refrigerants and dielectric fluids, pure liquids, nanofluids, hydrocarbons and additive mixtures, as well as natural and synthetic colloidal solutions. Nucleate pool boiling is an efficient and effective method of boiling because high heat fluxes are possible with moderate temperature differences. It is characterized by the growth of bubbles on a heated s...

  2. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.

  3. A swimming pool array for ultra high energy showers

    Science.gov (United States)

    Yodh, Gaurang B.; Shoup, Anthony; Barwick, Steve; Goodman, Jordan A.

    1992-11-01

    A very preliminary design concept for an array using water Cherenkov counters, built out of commercially available backyard swimming pools, to sample the electromagnetic and muonic components of ultra high energy showers at large lateral distances is presented. The expected performance of the pools is estimated using the observed lateral distributions by scintillator and water Cherenkov arrays at energies above 1019 eV and simulations.

  4. Lip and tooth injuries at public swimming pools in Austria.

    Science.gov (United States)

    Lechner, Katharina; Connert, Thomas; Kühl, Sebastian; Filippi, Andreas

    2017-06-01

    There is an increased risk of orofacial injuries in swimming pool facilities. Nevertheless, only a few studies have addressed this issue. The aim of this study was to identify the frequency of lip and tooth injuries at public swimming pools in Austria. A further aim was to examine which gender and age groups were affected, where and why these injuries occurred, and whether pool attendants had sufficient knowledge of dental first-aid measures. A total of 764 pool attendants in Austria were contacted by telephone and 689 participated in the study (90.2%). The attendants were interviewed retrospectively about accident occurrences in 2014 by a standardized questionnaire. Responses to the provision of first aid and choice of storage medium for avulsed teeth were subsequently evaluated. The frequency of lip injuries was 19.0%, and tooth injuries were 11.3%. Male bathers (P < .05) and children under 12 years (P < .001) most frequently suffered injuries. The waterslide was the most common accident site. The most common cause of lip injuries was slipping on wet surfaces (39.0%), and for tooth injuries it was collisions with other persons or objects (each 28.1%). The pool attendants' responses were predominantly good or sufficient on first aid, with the exception of what storage medium to choose. Tooth rescue boxes were available in only 8.6% of all pool facilities. Orofacial injuries are a frequently occurring problem in swimming pool facilities. The pool attendants' knowledge on first-aid care of tooth injuries could still be improved. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A hierarchic sustainability dashboard to evaluate logistics pooling

    OpenAIRE

    Morana, Joëlle; Gonzalez-Feliu, Jesus

    2014-01-01

    Logistics pooling is now a major challenge in supply chain management, though it remains a little known activity in which the different actors involved use different approaches whose objectives are not always the same and with sometimes conflicting standpoints. This purpose of this article is to define, on the basis of a detailed analysis of the literature, a grid for interpreting and a dashboard for evaluating the sustainable performance of pooled delivery systems. Firstly, an analysis of th...

  6. Predicting how altering propagule pressure changes establishment rates of biological invaders across species pools.

    Science.gov (United States)

    Brockerhoff, Eckehard G; Kimberley, Mark; Liebhold, Andrew M; Haack, Robert A; Cavey, Joseph F

    2014-03-01

    Biological invasions resulting from international trade can cause major environmental and economic impacts. Propagule pressure is perhaps the most important factor influencing establishment, although actual arrival rates of species are rarely recorded. Furthermore, the pool of potential invaders includes many species that vary in their arrival rate and establishment potential. Therefore, we stress that it is essential to consider the size and composition of species pools arriving from source regions when estimating probabilities of establishment and effects of pathway infestation rates. To address this, we developed a novel framework and modeling approach to enable prediction of future establishments in relation to changes in arrival rate across entire species pools. We utilized 13 828 border interception records from the United States and New Zealand for 444 true bark beetle (Scolytinae) and longhorned beetle (Cerambycidae) species detected between 1949 and 2008 as proxies for arrival rates to model the relationship between arrival and establishment rates. Nonlinearity in this relationship implies that measures intended to reduce the unintended transport of potential invaders (such as phytosanitary treatments) must be highly effective in order to substantially reduce the rate of future invasions, particularly if trade volumes continue to increase.

  7. Competition and power pooling in the electricity industry

    International Nuclear Information System (INIS)

    Jasinski, P.; Yarrow, G.; Fusaro, P.

    1995-01-01

    Two contributions to the debate on power pooling and competition in the electricity supply industry are presented. In the first, the situation in England and Wales where power pooling was introduced shortly before privatization is analysed. Pooling has existed for many years in the USA but as an inter-generator arrangement designed to optimize production and costs. The British system sought in addition to establish a spot market in which bulk buyers as well as bulk suppliers could participate. There are however obvious weaknesses in the pool as a competitive market and it is argued that a combination of pooling arrangements and longer-term bilateral supply contracts are more likely to offer the prospect of workably competitive and efficient outcomes. The second contribution discusses how competitive markets will evolve in the USA under the new regime of less onerous regulation heralded by the Energy Policy Act if 1992 and the emergence of electricity trading markets which followed. In particular, the proposal by the California Public Utility commission favouring a mandatory Poolco is examined. Poolco would operate the transmission grid and dispatch generating plants while the utilities would retain ownership of transmission facilities and be required to supply the pool. This is seen as representing only partial deregulation and not to be consistent with moves to further competition and encourage free markets. (U.K.)

  8. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  9. LNG pool fire simulation for domino effect analysis

    International Nuclear Information System (INIS)

    Masum Jujuly, Muhammad; Rahman, Aziz; Ahmed, Salim; Khan, Faisal

    2015-01-01

    A three-dimensional computational fluid dynamics (CFD) simulation of liquefied natural gas (LNG) pool fire has been performed using ANSYS CFX-14. The CFD model solves the fundamental governing equations of fluid dynamics, namely, the continuity, momentum and energy equations. Several built-in sub-models are used to capture the characteristics of pool fire. The Reynolds-averaged Navier–Stokes (RANS) equation for turbulence and the eddy-dissipation model for non-premixed combustion are used. For thermal radiation, the Monte Carlo (MC) radiation model is used with the Magnussen soot model. The CFD results are compared with a set of experimental data for validation; the results are consistent with experimental data. CFD results show that the wind speed has significant contribution on the behavior of pool fire and its domino effects. The radiation contours are also obtained from CFD post processing, which can be applied for risk analysis. The outcome of this study will be helpful for better understanding of the domino effects of pool fire in complex geometrical settings of process industries. - Highlights: • Simulation of pool fire using computational fluid dynamics (CFD) model. • Integration of CFD based pool fire model with domino effect. • Application of the integrated CFD based domino effect analysis

  10. Seasonal variation in Chironomid emergence from coastal pools

    Directory of Open Access Journals (Sweden)

    Alexander T. Egan

    2015-07-01

    Full Text Available Understanding the phenology of emergences can be useful in determining seasonal chironomid life cycle patterns, which are often influenced by ice cover and temperature in cold climates. Lake Superior is the largest lake in North America and with a mean surface temperature of 3.9 °C influences regional climate. Coastal pools at Isle Royale, a wilderness archipelago in the northern part of the lake, occur in dense patches on low-gradient volcanic bedrock between the lakeshore and forest, creating variable microhabitats for Chironomidae. Four sites were sampled monthly from April to October, 2010. Surface-floating pupal exuviae were collected from a series of pools in two zones: a lower zone near the lake influenced by wave splash, and an upper zone near the forest and influenced by upland runoff. We used Jaccard’s and Whittaker’s diversity indexes to test community similarity across months. Temperature loggers in pools collected hourly readings for most of the study. Assemblage emergences were stable in upper pools, with significant similarity across late spring and summer months. Assemblages were seasonally variable in lower pools, with significant dissimilarity across spring, summer, and fall months. Few species in either zone were unique to spring or fall months. However, many summer species in the splash zone had a narrow emergence period occurring during calm weather following distinct increases in mean water temperature. Regardless of input of cold lake water to the lower zone, pools from both zones generally had corresponding temperature trends.

  11. Review of steam jet condensation in a water pool

    International Nuclear Information System (INIS)

    Kim, Y. S.; Song, C. H.; Park, C. K.; Kang, H. S.; Jeon, H. G.; Yoon, Y. J.

    2002-01-01

    In the advanced nuclear power plants including APR1400, the SDVS is adopted to increase the plant safety using the concept of feed-and-bleed operation. In the case of the TLOFW, the POSRV located at the top of the pressurizer is expected to open due to the pressurization of the reactor coolant system and discharges steam and/or water mixture into the water pool, where the mixture is condensed. During the condensation of the mixture, thermal-hydraulic loads such as pressure and temperature variations are induced to the pool structure. For the pool structure design, such thermal-hydraulic aspects should be considered. Understanding the phenomena of the submerged steam jet condensation in a water pool is helpful for system designers to design proper pool structure, sparger, and supports etc. This paper reviews and evaluates the steam jet condensation in a water pool on the physical phenomena of the steam condensation including condensation regime map, heat transfer coefficient, steam plume, steam jet condensation load, and steam jet induced flow

  12. Detection of 41Ar diffusion from a TRIGA pool

    International Nuclear Information System (INIS)

    Foss, Scott; Nelson, George

    1990-01-01

    Argon-41 levels in very low concentrations in the reactor room air can be inferred from the rate of escape from the pool water surface. The rate of Argon-41 diffusion from pool water to room air was determined by the measurement of the activity buildup in containers of air in contact with the pool surface. The Argon-41 concentration in each container was measured by gamma-ray spectrometry with a calibrated GeLi detector. At 100 KW power with the water temperature at 10 deg. Celsius the total release of Argon-41 was determined to be 3.5e10±15% atoms for 80 minutes of operation. The corresponding activity released from the pool was 98.6 microcuries, while the total activity produced in the pool was 4900 microcuries. The diffusion coefficient of Argon-41 from the pool water surface to the air at this temperature was measured to be 3.14e-14 sec-cm 2 . (author)

  13. Structural analysis of the reactor pool for the RRRP

    International Nuclear Information System (INIS)

    Alberro, J.G.; Abbate, A.D.

    2005-01-01

    The purpose of the present document is to describe the structural design of the Reactor Pool relevant to the RRRP (Replacement Research Reactor Project) for the Australian Nuclear Science and Technology Organisation. The structural analysis required coordinated design, engineering, analysis, and fabrication efforts. The pool has been designed, manufactured, and inspected following as guideline the ASME Boiler and Pressure Vessel Code, which defines the requirements for the pool to withstand hydrostatic and mechanical forces, ensuring its integrity throughout its lifetime. Standard off-the-shelf finite element programs (Nastran and Ansys codes) were used to evaluate the pool and further qualify the design and its construction. Both global and local effect analyses were carried out. The global analysis covers the structural integrity of the pool wall (6 mm thick) considering the different load states acting on it, namely hydrostatic pressure, thermal expansion, and seismic event. The local analysis evaluates the structural behaviour of the pool at specific points resulting from the interaction among components. It is confirmed that maximum stresses and displacements fall below the allowable values required by the ASME Boiler and Pressure Vessel Code. The water pressure analysis was validated by means of a hydrostatic test. (authors)

  14. Probabilistic analysis of some safety aspects of a swimming pool reactor

    International Nuclear Information System (INIS)

    Lieber, K.; Nicolescu, T.

    1984-01-01

    A probabilistic risk analysis of some safety aspects without the investigation of radioactivity release has been performed for the 10 MW (thermal) swimming-pool research reactor SAPHIR. Our presentation is focused on the 7 internal initiating events found to be relevant with respect to accident sequences that could result with core melt due to loss of coolant or overcriticality. The results are given by the core melt frequencies for the investigated accident sequences. It could be demonstrated by our investigation that the core melt hazard of the reactor is extremely low. (author)

  15. Uptake of inorganic phosphorus by the aquatic plant Isoetes australis inhabiting oligotrophic vernal rock pools

    DEFF Research Database (Denmark)

    Christiansen, Nina Høj; Pulido, Cristina; Pedersen, Ole

    2017-01-01

    The submerged aquatic freshwater macrophyte Isoetes australis S. Williams grows in rock pools situated in south-western Australia, an environment where dissolved inorganic phosphorus (Pi) availability possibly limits growth. In contrast to the two coexisting aquatic species, Glossostigma drummundii...... experiment revealed high amounts of Pi translocation internally in the plant which seemed to go from roots and oldest leaves to younger leaves. As a result of the high root to shoot ratio, high surface area, root uptake kinetics, and sediment Pi availability, roots accounted for 87% of plant Pi uptake...

  16. Experimental Investigation of the Hot Water Layer Effect on Upward Flow Open Pool Reactor Operability

    International Nuclear Information System (INIS)

    Abou Elmaaty, T.

    2014-01-01

    The open pool reactor offers a high degree of reliability in the handling and manoeuvring, the replacement of reactor internal components and the suing of vertical irradiation channels. The protection of both the operators and the reactor hall environment against radiation hazards is considered a matter of interest. So, a hot water layer is implemented above many of the research reactors main pool, especially those whose flow direction is upward flow. An experimental work was carried out to ensure the operability of the upward flow open pool research reactor with / without the hot water layer. The performed experiment showed that, the hot water layer is produced an inverse buoyant force make the water to diffuse downward against the ordinary natural circulation from the reactor core. An upward flow - open pool research reactor (with a power greater than 20 M watt) could not wok without a hot water layer. The high temperature of the hot water layer surface could release a considerable amount of water vapour into the reactor hall, so a heat and mass transfer model is built based on the measured hot water layer surface temperature to calculate the amount of released water vapour during the reactor operating period. The effects of many parameters like the ambient air temperature, the reactor hall relative humidity and the speed of the pushed air layer above the top pool end on the evaporation rate is studied. The current study showed that, the hot water layer system is considered an efficient shielding system against Gamma radiation for open pool upward flow reactor and that system should be operated before the reactor start up by a suitable period of time. While, the heat and mass transfer model results showed that, the amount of the released water vapour is increased as a result of both the increase in hot water layer surface temperature and the increase in air layer speed. As the increase in hot water layer surface temperature could produce a good operability

  17. Experimental Investigation of the Hot Water Layer Effect on Upward Flow Open Pool Reactor Operability

    International Nuclear Information System (INIS)

    Abou Elmaaty, T.

    2015-01-01

    The open pool reactor offers a high degree of reliability in the handling and manoeuvring, the replacement of reactor internal components and the swing of vertical irradiation channels. The protection of both the operators and the reactor hall environment against radiation hazards is considered a matter of interest. So, a hot water layer implemented above many of the research reactors main pool, especially those whose flow direction is upward flow. An experimental work was carried out to ensure the operability of the upward flow open pool research reactor with / without the hot water layer. The performed experiment showed that, the hot water layer produced an inverse buoyant force making the water to diffuse downward against the ordinary natural circulation from the reactor core. An upward flow-open pool research reactor (with a power greater than 20 Mw) could not wok without a hot water layer. The high temperature of the hot water layer surface could release a considerable amount of water vapour into the reactor hall, so a heat and mass transfer model is built based on the measured hot water layer surface temperature to calculate the amount of released water vapour during the reactor operating period. The effects of many parameters like the ambient air temperature, the reactor hall relative humidity and the speed of the pushed air layer above the top pool end on the evaporation rate is studied. The current study showed that, the hot water layer system is considered an efficient shielding system against gamma radiation for open pool upward flow reactor and that system should be operated before the reactor start up by a suitable period of time. While, the heat and mass transfer model results showed that, the amount of the released water vapour is increased as a result of both the increase in hot water layer surface temperature and the increase in air layer speed. As the increase in hot water layer surface temperature could produce a good operability conditions from

  18. 76 FR 64085 - Post-2014 Resource Pool-Loveland Area Projects, Final Power Allocation

    Science.gov (United States)

    2011-10-17

    ... Resource Pool; Loveland Area Projects, General Eligibility Criteria. The resource pool for capacity and... transmission in Kansas. Final allocation of the Post-2014 Resource Pool; Loveland Area Projects, is contingent...

  19. Dolo y mala fe

    Directory of Open Access Journals (Sweden)

    Carlos Arturo Gómez Pavajeau

    2010-12-01

    Full Text Available Se ha dicho por grandes penalistas que las tesis en nuestra disciplina son una eterna vuelta al pasado. Empero, debe constatarse, que ello se ha dicho en un sentido de lo clásico: una vuelta a lo que resulta digno de admirar en cualquier época, toda vez que las experiencias históricas negativas nos previenen de repetir el pasado, razón fundamental por la cual debemos conocerlo. En este escrito pretendemos mostrar cómo algunas tendencias actuales nos indican que épocas nefastas ya superadas pueden repetirse, lo cual particularmente sucede tanto con la noción de dolo como con la de mala fe, concepto que de imponerse destruiría, a la manera como se derrumba un castillo de naipes, el sólido edificio dogmático construido por el Derecho penal liberal.

  20. Computational study of the mixed cooling effects on the in-vessel retention of a molten pool in a nuclear reactor

    International Nuclear Information System (INIS)

    Kim, Byung Seok; Sohn, Chang Hyun; Ahn, Kwang Il

    2004-01-01

    The retention of a molten pool vessel cooled by internal vessel reflooding and/or external vessel reactor cavity flooding has been considered as one of severe accident management strategies. The present numerical study investigates the effect of both internal and external vessel mixed cooling on an internally heated molten pool. The molten pool is confined in a hemispherical vessel with reference to the thermal behavior of the vessel wall. In this study, our numerical model used a scaled-down reactor vessel of a KSNP (Korea Standard Nuclear Power) reactor design of 1000 MWe (a pressurized water reactor with a large and dry containment). Well-known temperature-dependent boiling heat transfer curves are applied to the internal and external vessel cooling boundaries. Radiative heat transfer has been considered in the case of dry internal vessel boundary condition. Computational results show that the external cooling vessel boundary conditions have better effectiveness than internal vessel cooling in the retention of the melt pool vessel failure

  1. Exchange bias variations of the seed and top NiFe layers in NiFe/FeMn/NiFe trilayer as a function of seed layer thickness

    International Nuclear Information System (INIS)

    Sankaranarayanan, V.K.; Yoon, S.M.; Kim, C.G.; Kim, C.O.

    2005-01-01

    Development of exchange bias at the seed and top NiFe layers in the NiFe (t nm)/FeMn(10 nm)/NiFe(5 nm) trilayer structure is investigated as a function of seed layer thickness, in the range of 2-20 nm. The seed NiFe layer shows maximum exchange bias at 4 nm seed layer thickness. The bias shows inverse thickness dependence with increasing thickness. The top NiFe layer on the other hand shows only half the bias of the seed layer which is retained even after the sharp fall in seed layer bias. The much smaller bias for the top NiFe layer is related to the difference in crystalline texture and spin orientations at the top FeMn/NiFe interface, in comparison to the bottom NiFe/FeMn interface which grows on a saturated NiFe layer with (1 1 1) orientation

  2. Magnitude and Uncertainty of Carbon Pools and Fluxes in the US Forests

    Science.gov (United States)

    Harris, N.; Saatchi, S. S.; Fore, A.; Yu, Y.; Woodall, C. W.; Ganguly, S.; Nemani, R. R.; Hagen, S.; Birdsey, R.; Brown, S.; Salas, W.; Johnson, K. D.

    2015-12-01

    Sassan Saatchi1,2, Stephan Hagen3, Christopher Woodall4 , Sangram Ganguly,5 Nancy Harris6, Sandra Brown7, Timothy Pearson7, Alexander Fore1, Yifan Yu1, Rama Nemani5, Gong Zhang5, William Salas4, Roger Cooke81 NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA2 Institute of Environment and Sustainability, University of California, Los Angeles, CA, 90095, USA3 Applied Geosolutions, 55 Main Street Suit 125, Newmarket, NH 03857, USA4 USDA Forest Service, Northern Research Station, Saint Paul, MN 55108, USA5 NASA Ames Research Center, Moffett Field, CA 94035, USA6 Forests Program, World Resources Institute, Washington, DC, 20002, USA7 Winrock International, Ecosystem Services Unit, Arlington, VA 22202, USA8 Risk Analysis Resources for the Future, Washington DC 20036-1400Assessment of the carbon sinks and sources associated with greenhouse gas (GHG) fluxes across the US forestlands is a priority of the national climate mitigation policy. However, estimates of fluxes from the land sector are less precise compared to other sectors because of the large sources of uncertainty in quantifying the carbon pools, emissions, and removals associated with anthropogenic (land use) and natural changes in the US forestlands. As part of the NASA's Carbon Monitoring System, we developed a methodology based on a combination of ground inventory and space observations to develop spatially refined carbon pools and fluxes including the gross emissions and sequestration of carbon at each 1-ha land unit across the forestlands in the continental United States (CONUS) for the period of 2006-2010. Here, we provide the magnitude and uncertainty of multiple pools and fluxes of the US forestlands and outline the observational requirements to reduce the uncertainties for developing national climate mitigation policies based on the carbon sequestration capacity of the US forest lands. Keywords: forests, carbon pools, greenhouse gas, land use, attribution

  3. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    OpenAIRE

    Mančić Marko V.; Živković Dragoljub S.; Milosavljević Peđa M.; Todorović Milena N.

    2014-01-01

    Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming po...

  4. Moessbauer study of C18N/Fe Langmuir-Blodgett layers

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmann, Erno [Institute of Chemistry, Eoetvoes Lorand University (Hungary); Telegdi, Judit [Institute of Nanochemistry and Catalysis, Chemical Research Center, HAS (Hungary); Nemeth, Zoltan, E-mail: hentes@chem.elte.hu; Vertes, Attila [Institute of Chemistry, Eoetvoes Lorand University (Hungary); Nyikos, Lajos [Institute of Nanochemistry and Catalysis, Chemical Research Center, HAS (Hungary)

    2012-03-15

    Langmuir-Blodgett (LB) films of octadecanoyl hydroxamic acid (C18N) complexed with Fe{sup 3 + } ions have been prepared at various subphase pH values. The LB films consisting of different number of layers were investigated by {sup 57}Fe conversion electron Moessbauer spectroscopy (CEM) at room temperature. The CEM detector contained a piece of {alpha}-iron, enriched with {sup 57}Fe, using as an internal standard. The Moessbauer pattern of the C18N/Fe LB films is a doublet with parameters {delta} = 0.35 mm/s and {Delta} = 0.74 mm/s. A gradual increase of the relative occurrence of the doublet compared to the sextet of the internal standard was observed with the increasing number of layers, indicating the nearly uniform distribution of Fe among the LB layers.

  5. Mössbauer and Kerr microscopy investigation of crystallization in FeCoB ribbons

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, V. Raghavendra, E-mail: varimalla@yahoo.com, E-mail: vrreddy@csr.res.in; Hussain, Zaineb; Babu, Hari [UGC DAE Consortium for Scientific Research, University Campus, Kandhwa Road, Indore-452001 India (India); Shrivastava, Namrata [School of Physics, DAVV, Khandwa Road, Indore – 452001 India (India); Gupta, Ajay [Amity Centre for Spintronic Materials, Amity University, Noida 201303.India (India)

    2016-05-23

    The present work reports the crystallization study of amorphous FeCoB ribbons using x-ray diffraction, {sup 57}Fe Mössbauer spectroscopy in transmission mode and magneto-optical Kerr (MOKE) microscopy. Annealing at 673 K is found to result in crystallization. From the Mossbauer measurements it is observed that the Fe magnetic moments are in the plane of sample for as-cast ribbon; α-FeCo, (Fe{sub 0.5}Co{sub 0.5}){sub 2}B and Fe{sub 2}B phases are formed after crystallization. MOKE microscopy revealed that wide 180° domain walls & narrow fingerprint domains are observed before crystallization and fine domains are observed after crystallization. The results are explained in terms of the presence of internal stresses and their annealing with thermal heat treatment.

  6. Pooled versus separate measurements of tree-ring stable isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dorado Linan, Isabel, E-mail: isabel@gfz-potsdam.de [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Gutierrez, Emilia, E-mail: emgutierrez@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Helle, Gerhard, E-mail: ghelle@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Heinrich, Ingo, E-mail: heinrich@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Andreu-Hayles, Laia, E-mail: laiandreu@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Tree-Ring Laboratory, Lamont-Doherty Earth Observatory of Columbia University, Palisades NY (United States); Planells, Octavi, E-mail: leocarpus@hotmail.com [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Leuenberger, Markus, E-mail: leuenberger@climate.unibe.ch [Climate and Environmental Physics, Physics Institute, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Oeschger Centre of Climate Change Research, University of Bern, Zaehringerstrasse 25, 3012 Bern (Switzerland); Buerger, Carmen, E-mail: buerger@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Schleser, Gerhard, E-mail: schleser@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany)

    2011-05-01

    {delta}{sup 13}C and {delta}{sup 18}O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the {delta}{sup 13}C and the {delta}{sup 18}O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing {delta}{sup 18}O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: {yields} Pooled {delta}{sup 13}C and {delta}{sup 18}O chronologies are expected to be similar to the mean. {yields} Empirical pooled chronologies {delta}{sup 13}C and

  7. Pooled versus separate measurements of tree-ring stable isotopes

    International Nuclear Information System (INIS)

    Dorado Linan, Isabel; Gutierrez, Emilia; Helle, Gerhard; Heinrich, Ingo; Andreu-Hayles, Laia; Planells, Octavi; Leuenberger, Markus; Buerger, Carmen; Schleser, Gerhard

    2011-01-01

    δ 13 C and δ 18 O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the δ 13 C and the δ 18 O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing δ 18 O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: → Pooled δ 13 C and δ 18 O chronologies are expected to be similar to the mean. → Empirical pooled chronologies δ 13 C and δ 18 O and the mean show a high synchronicity. → Pooled chronologies differ

  8. Preparation and Mechanical Properties of TiC-Fe Cermets and TiC-Fe/Fe Bilayer Composites

    Science.gov (United States)

    Zheng, Yong; Zhou, Yang; Li, Runfeng; Wang, Jiaqi; Chen, Lulu; Li, Shibo

    2017-10-01

    TiC-Fe cermets and TiC-Fe/Fe bilayer composites consisting of a pure Fe layer and a TiC-Fe cermets layer were fabricated by hot-pressing sintering. The pure Fe layer contributes to the toughness of composites, and the TiC-Fe cermets layer endows the composites with an improved tensile strength and hardness. The effect of TiC contents (30-60 vol.%) on the mechanical properties of TiC-Fe cermets and TiC-Fe/Fe bilayer composites was investigated. Among the TiC-Fe cermets, the 40 vol.% TiC-Fe cermets possessed the highest tensile strength of 581 MPa and Vickers hardness of 5.1 GPa. The maximum fracture toughness of 17.0 MPa m1/2 was achieved for the TiC-Fe cermets with 30 vol.% TiC. For the TiC-Fe/Fe bilayer composites, the 40 vol.% TiC-Fe/Fe bilayer composite owns the maximum tensile strength of 588 MPa, which is higher than that of 40 vol.% TiC-Fe cermets. In addition, the 33.5% increment of tensile strength of 30 vol.% TiC-Fe/Fe bilayer composite comparing with the 30 vol.% TiC-Fe cermets, which is attributed to the 30 vol.% TiC-Fe/Fe bilayer composite exhibited the largest interlaminar shear strength of 335 MPa. The bilayer composites are expected to be used as wear resistance components in some heavy wear conditions.

  9. Modelling of multicomponent diffusion in a two-phase oxide-metal corium pool by a diffuse interface method

    International Nuclear Information System (INIS)

    Cardon, Clement

    2016-01-01

    This Ph.D. topic is focused on the modelling of stratification kinetics for an oxide-metal corium pool (U-O-Zr-steel system) in terms of multicomponent and multiphase diffusion. This work is part of a larger research effort for the development of a detailed corium pool modelling based on a CFD approach for thermal hydraulics. The overall goal is to improve the understanding of the involved phenomena and obtain closure laws for integral macroscopic models. The phase-field method coupled with an energy functional using the CALPHAD method appears to be relevant for this purpose. In a first part, we have developed a diffuse interface model in order to describe the diffusion process in the U-O system. This model has been coupled with a CALPHAD thermodynamic database and its parameterization has been developed with, in particular, an up-scaling procedure related to the interface thickness. Then, within the framework of a modelling for the U-O-Zr ternary system, we have proposed a generalization of the diffuse interface model through an assumption of local equilibrium for redox mechanisms. A particular attention was paid to the model analysis by 1D numerical simulations with a special focus on the steady state composition profiles. Finally we have applied this model to the U-O-Zr-Fe system. For that purpose, we have considered a configuration close to small-scale experimental tests of oxide-metal corium pool stratification. (author) [fr

  10. PWR upper/lower internals shield

    Energy Technology Data Exchange (ETDEWEB)

    Homyk, W.A. [Indian Point Station, Buchanan, NY (United States)

    1995-03-01

    During refueling of a nuclear power plant, the reactor upper internals must be removed from the reactor vessel to permit transfer of the fuel. The upper internals are stored in the flooded reactor cavity. Refueling personnel working in containment at a number of nuclear stations typically receive radiation exposure from a portion of the highly contaminated upper intervals package which extends above the normal water level of the refueling pool. This same issue exists with reactor lower internals withdrawn for inservice inspection activities. One solution to this problem is to provide adequate shielding of the unimmersed portion. The use of lead sheets or blankets for shielding of the protruding components would be time consuming and require more effort for installation since the shielding mass would need to be transported to a support structure over the refueling pool. A preferable approach is to use the existing shielding mass of the refueling pool water. A method of shielding was devised which would use a vacuum pump to draw refueling pool water into an inverted canister suspended over the upper internals to provide shielding from the normally exposed components. During the Spring 1993 refueling of Indian Point 2 (IP2), a prototype shield device was demonstrated. This shield consists of a cylindrical tank open at the bottom that is suspended over the refueling pool with I-beams. The lower lip of the tank is two feet below normal pool level. After installation, the air width of the natural shielding provided by the existing pool water. This paper describes the design, development, testing and demonstration of the prototype device.

  11. Correlation of reactivity with structural factors in a series of Fe(II) substituted cobalt ferrites

    International Nuclear Information System (INIS)

    Sileo, Elsa E.; Garcia Rodenas, Luis; Paiva-Santos, Carlos O.; Stephens, Peter W.; Morando, Pedro J.; Blesa, Miguel A.

    2006-01-01

    A series of powdered cobalt ferrites, Co x Fe 3- x O 4 with 0.66≤x II , were synthesized by a mild procedure, and their Fe and Co site occupancies and structural characteristics were explored using X-ray anomalous scattering and the Rietveld refinement method. The dissolution kinetics, measured in 0.1 M oxalic acid aqueous solution at 70 deg. C, indicate in all cases the operation of a contracting volume rate law. The specific rates increased with the Fe II content following approximately a second-order polynomial expression. This result suggests that the transfer of Fe III controls the dissolution rate, and that the leaching of a first layer of ions Co II and Fe II leaves exposed a surface enriched in slower dissolving octahedral Fe III ions. Within this model, inner vicinal lattice Fe II accelerates the rate of Fe III transfer via internal electron hopping. A chain mechanism, involving successive electron transfers, fits the data very well. - Graphical abstract: The electron exchange between octahedral Fe II and Fe III ions has important consequences on the specific dissolution rates. Display Omitted

  12. Internal friction and longitudinal modulus behaviour of multiferroic PbZr0.52Ti0.48O3+Ni0.93Co0.02Mn0.05Fe1.95O4-δ particulate composites

    International Nuclear Information System (INIS)

    Ramana, M Venkata; Sreenivasulu, G; Reddy, N Ramamanohar; Kumar, K V Siva; Murty, B S; Murthy, V R K

    2007-01-01

    Multiferroic particulate composites with composition xNi 0.93 Co 0.02 Mn 0.5 Fe 1.95 O 4-δ + (1 - x)PbZr 0.52 Ti 0.48 O 3 where the molar fraction x varies as 0, 0.1, 0.2, 0.3, 0.4 and 0.5 were prepared by the conventional ceramic method. The presence of two phases was confirmed by x-ray diffraction and scanning electron microscopy. The temperature variation of the longitudinal modulus (L) and the internal friction (Q -1 ) of these particulate composites at 104.387 kHz was studied in the wide temperature range 30-420 deg. C. The temperature variation of the longitudinal modulus (L) in each composition of these particulate composites showed two abrupt minima. One minimum coincided with the ferroelectric-paraelectric Curie transition temperature (θ E ) and the other with the ferrimagnetic-paramagnetic Curie transition (θ M ) temperature. The internal friction (Q -1 ) measurements also showed two sharp peaks in each composition corresponding to those temperatures where the minima were noticed in the temperature variation of the longitudinal modulus behaviour. The Curie transition temperature of pure ferrite was found to be 560 deg. C. Addition of 10% of ferrite to ferroelectric in a magnetoelectric (ME) composite resulted in a 360 deg. C fall in θ M and with a further increase in ferrite content the θ M variation was found to be very nominal. However, no significant ferroelectric Curie transition temperature shift could be noticed. This behaviour is explained in the light of structural phase transitions in these multiferroic particulate composites. These ME composites were prepared with a view to using them as ME sensors and transducers

  13. Convective Cold Pool Structure and Boundary Layer Recovery in DYNAMO

    Science.gov (United States)

    Savarin, A.; Chen, S. S.; Kerns, B. W.; Lee, C.; Jorgensen, D. P.

    2012-12-01

    One of the key factors controlling convective cloud systems in the Madden-Julian Oscillation (MJO) over the tropical Indian Ocean is the property of the atmospheric boundary layer. Convective downdrafts and precipitation from the cloud systems produce cold pools in the boundary layer, which can inhibit subsequent development of convection. The recovery time is the time it takes for the boundary layer to return to pre convective conditions. It may affect the variability of the convection on various time scales during the initiation of MJO. This study examines the convective cold pool structure and boundary layer recovery using the NOAA WP-3D aircraft observations, include the flight-level, Doppler radar, and GPS dropsonde data, collected during the Dynamics of MJO (DYNAMO) field campaign from November-December 2011. The depth and strength of convective cold pools are defined by the negative buoyancy, which can be computed from the dropsonde data. Convective downdraft can be affected by environmental water vapor due to entrainment. Mid-level dry air observed during the convectively suppressed phase of MJO seems to enhance convective downdraft, making the cold pools stronger and deeper. Recovery of the cold pools in the boundary layer is determined by the strength and depth of the cold pools and also the air-sea heat and moisture fluxes. Given that the water vapor and surface winds are distinct for the convectively active and suppressed phases of MJO over the Indian Ocean, the aircraft data are stratified by the two different large-scale regimes of MJO. Preliminary results show that the strength and depth of the cold pools are inversely correlated with the surrounding mid-level moisture. During the convectively suppressed phase, the recovery time is ~5-20 hours in relative weak wind condition with small air-sea fluxes. The recovery time is generally less than 6 hours during the active phase of MJO with moist mid-levels and stronger surface wind and air-sea fluxes.

  14. UPDG: Utilities package for data analysis of Pooled DNA GWAS

    Directory of Open Access Journals (Sweden)

    Ho Daniel WH

    2012-01-01

    Full Text Available Abstract Background Despite being a well-established strategy for cost reduction in disease gene mapping, pooled DNA association study is much less popular than the individual DNA approach. This situation is especially true for pooled DNA genomewide association study (GWAS, for which very few computer resources have been developed for its data analysis. This motivates the development of UPDG (Utilities package for data analysis of Pooled DNA GWAS. Results UPDG represents a generalized framework for data analysis of pooled DNA GWAS with the integration of Unix/Linux shell operations, Perl programs and R scripts. With the input of raw intensity data from GWAS, UPDG performs the following tasks in a stepwise manner: raw data manipulation, correction for allelic preferential amplification, normalization, nested analysis of variance for genetic association testing, and summarization of analysis results. Detailed instructions, procedures and commands are provided in the comprehensive user manual describing the whole process from preliminary preparation of software installation to final outcome acquisition. An example dataset (input files and sample output files is also included in the package so that users can easily familiarize themselves with the data file formats, working procedures and expected output. Therefore, UPDG is especially useful for users with some computer knowledge, but without a sophisticated programming background. Conclusions UPDG provides a free, simple and platform-independent one-stop service to scientists working on pooled DNA GWAS data analysis, but with less advanced programming knowledge. It is our vision and mission to reduce the hindrance for performing data analysis of pooled DNA GWAS through our contribution of UPDG. More importantly, we hope to promote the popularity of pooled DNA GWAS, which is a very useful research strategy.

  15. Biophysical Interactions within Step-Pool Mountain Streams Following Wildfire

    Science.gov (United States)

    Parker, A.; Chin, A.; O'Dowd, A. P.

    2014-12-01

    Recovery of riverine ecosystems following disturbance is driven by a variety of interacting processes. Wildfires pose increasing disturbances to riverine landscapes, with rising frequencies and magnitudes owing to warming climates and increased fuel loads. The effects of wildfire include loss of vegetation, elevated runoff and flash floods, erosion and deposition, and changing biological habitats and communities. Understanding process interactions in post-fire landscapes is increasingly urgent for successful management and restoration of affected ecosystems. In steep channels, steps and pools provide prominent habitats for organisms and structural integrity in high energy environments. Step-pools are typically stable, responding to extreme events with recurrence intervals often exceeding 50 years. Once wildfire occurs, however, intensification of post-fire flood events can potentially overpower the inherent stability of these systems, with significant consequences for aquatic life and human well-being downstream. This study examined the short-term response of step-pool streams following the 2012 Waldo Canyon Fire in Colorado. We explored interacting feedbacks among geomorphology, hydrology, and ecology in the post-fire environment. At selected sites with varying burn severity, we established baseline conditions immediately after the fire with channel surveys, biological assessment using benthic macroinvertebrates, sediment analysis including pebble counts, and precipitation gauging. Repeat measurements after major storm events over several years enabled analysis of the interacting feedbacks among post-fire processes. We found that channels able to retain the step-pool structure changed less and facilitated recovery more readily. Step habitats maintained higher percentages of sensitive macroinvertebrate taxa compared to pools through post-fire floods. Sites burned with high severity experienced greater reduction in the percentage of sensitive taxa. The decimation of

  16. SPOOL-FIRE: an IBM 370/195 code for the analysis of combined spray and pool burning of sodium

    International Nuclear Information System (INIS)

    Charak, I.; Person, L.W.

    1976-01-01

    A code for the computation of the pressure and temperatures within a containment building as a result of a sodium fire is described. The fire is assumed to occur in two distinct phases: a spray and a pool. The spray fire is conservatively assumed to occur instantaneously. The pool fire model used is the SOFIRE-II model developed by Atomics International. The code calculates all important temperatures, accounting for heat loss from the building to the environment, as well as leakage of the containment atmosphere under conditions of internal overpressure. The IBM CSMP methodology is used to solve the set of ordinary differential equations which model the system. The use of CSMP allows the user considerable flexibility in modifying the models employed

  17. Experimental investigation of particulate debris spreading in a pool

    Energy Technology Data Exchange (ETDEWEB)

    Konovalenko, A., E-mail: kono@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Basso, S., E-mail: simoneb@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Kudinov, P., E-mail: pkudinov@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Yakush, S.E., E-mail: yakush@ipmnet.ru [Institute for Problems in Mechanics of the Russian Academy of Sciences, Ave. Vernadskogo 101 Bldg 1, Moscow 119526 (Russian Federation)

    2016-02-15

    Termination of severe accident progression by core debris cooling in a deep pool of water under reactor vessel is considered in several designs of light water reactors. However, success of this accident mitigation strategy is contingent upon the effectiveness of heat removal by natural circulation from the debris bed. It is assumed that a porous bed will be formed in the pool in the process of core melt fragmentation and quenching. Debris bed coolability depends on its properties and system conditions. The properties of the bed, including its geometry are the outcomes of the debris bed formation process. Spreading of the debris particles in the pool by two-phase turbulent flows induced by the heat generated in the bed can affect the shape of the bed and thus influence its coolability. The goal of this work is to provide experimental data on spreading of solid particles in the pool by large-scale two-phase flow. The aim is to provide data necessary for understanding of separate effects and for development and validation of models and codes. Validated codes can be then used for prediction of debris bed formation under prototypic severe accident conditions. In PDS-P (Particulate Debris Spreading in the Pool) experiments, air injection at the bottom of the test section is employed as a means to create large-scale flow in the pool in isothermal conditions. The test section is a rectangular tank with a 2D slice geometry, it has fixed width (72 mm), adjustable length (up to 1.5 m) and allows water filling to the depth of up to 1 m. Variable pool length and depth allows studying two-phase circulating flows of different characteristic sizes and patterns. The average void fraction in the pool is determined by video recording and subsequent image processing. Particles are supplied from the top of the facility above the water surface. Results of several series of PDS-P experiments are reported in this paper. The influence of the gas flow rate, pool dimensions, particle density

  18. Pool swell sub-scale testing and code comparison

    International Nuclear Information System (INIS)

    Elisson, K.

    1981-01-01

    The main objective of the experiment was to investigate the pool swell dynamics in general and the forces on the lowered central part of the diaphragm between drywell and wetwell in particular. Apart from the high speed camera pressure transducers and strain gauges were used to monitor the transient. Data was recorded on a 14 channel FM recorder and then digitalised and plotted. In total more than one hundred tests were performed including parametric variations of for example geometry, break flow, initial drywell pressure and initial water level. In parallel to this experiment pool swell calculations have been performed with the computer codes COPTA and STEALTH. COPTA which is a lumped mass code for pressure suppression containment analysis has a slug pool swell mode. STEALTH which is a general purpose lagrangian hydrodynamics code has been used in a 2-D axisymmetric version. The STEALTH code has been used to calculate the radial variations in the vertical displacement and velocity of the pool surface and to predict the load on the lowered central part of the diaphragm. A comparison between the calculations and the experimental data indicates that both codes are sufficiently correct in their description of the pool swell transient. (orig.)

  19. Immobilization of radioactive waste sludge from spent fuel storage pool

    International Nuclear Information System (INIS)

    Pavlovic, R.; Plecas, I.

    1998-01-01

    In the last forty years, in FR Yugoslavia, as result of the research reactors' operation and radionuclides application in medicine, industry and agriculture, radioactive waste materials of the different categories and various levels of specific activities were generated. As a temporary solution, these radioactive waste materials are stored in the two hanger type interim storages for solid waste and some type of liquid waste packed in plastic barrels, and one of three stainless steal underground containers for other types of liquid waste. Spent fuel elements from nuclear reactors in the Vinca Institute have been temporary stored in water filled storage pool. Due to the fact that the water in the spent fuel elements storage pool have not been purified for a long time, all metallic components submerged in the water have been hardly corroded and significant amount of the sludge has been settled on the bottom of the pool. As a first step in improving spent fuel elements storage conditions and slowing down corrosion in the storage spent fuel elements pool we have decided to remove the sludge from the bottom of the pool. Although not high, but slightly radioactive, this sludge had to be treated as radioactive waste material. Some aspects of immobilisation, conditioning and storage of this sludge are presented in this paper. (author

  20. Research progresses and future directions on pool boiling heat transfer

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2015-12-01

    Full Text Available This paper reviews the previous work carried on pool boiling heat transfer during heating of various liquids and commodities categorized as refrigerants and dielectric fluids, pure liquids, nanofluids, hydrocarbons and additive mixtures, as well as natural and synthetic colloidal solutions. Nucleate pool boiling is an efficient and effective method of boiling because high heat fluxes are possible with moderate temperature differences. It is characterized by the growth of bubbles on a heated surface. It occurs during boiling of liquids for excess temperature ranging from 5 to 30 °C in various processes related to high vaporization of liquid for specific purposes like sugarcane juice heating for jaggery making, milk heating for khoa making, steam generation, cooling of electronic equipments, refrigeration and etcetera. In this review paper, pool boiling method during heating of liquids for specific purpose is depicted. It is inferred that enhancement in pool boiling heat transfer is a challenging and complex task. Also, recent research and use of various correlations for natural convection pool boiling is reviewed.

  1. SBWR PCCS vent phenomena and suppression pool mixing

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, P. [Thermal-Hydraulics Lab., Paul Scherrer Institute, Villigen (Switzerland); Andreani, M. [Nuclear Engineering Lab., Swiss Federal Institute of Technology, Zurich (Switzerland)

    1995-09-01

    The most important phenomena influencing the effectiveness of the pressure suppression capability of the water pool within the Wetwell compartment of the SBWR Containment, during the period of Passive Containment Cooling System (PCCS) venting, have been critically reviewed. In addition, calculations have been carried-out to determine the condensation of the vented steam and the distribution of the energy deposited in the liquid pool. It has been found that a large contribution to the vapour suppression is due to condensation inside the vent pipe. The condensation rate of the steam inside the bubbles, produced at the vent exit, during their rise to the surface, may however be rather low, because of the large size bubbles. This can lead to vapour channelling to the Wetwell gas space. The above comments are likely to be ameliorated if the vent exit is a distributed source or sparger. Due to the large water flow rates within the {open_quotes}bubbly two-phase plume{close_quotes} generated by the gas injection, the water in the pool above the vent exit is likely to be heated nearly isothermally (perfect mixing). The effect of the suppression pool walls would be to enhance the recirculation and, consequently to promote mixing. The large size of the bubbles therein and of the walls on pool mixing are the most severe difficulties in extrapolating the results from scaled experiments to prototypical conditions.

  2. Water inventory management in condenser pool of boiling water reactor

    International Nuclear Information System (INIS)

    Gluntz, D.M.

    1996-01-01

    An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs

  3. Determination of isotopomers in pools of molecules with polyisotopic elements

    International Nuclear Information System (INIS)

    Zyakun, A.M.; Brenninkmeijer, C.A.M.

    2002-01-01

    Polyisotopic element atoms that are present in a molecule form a pool of isotopomer molecules. Mono- and polyisotopomers are distinguished depending on the quantity of atoms of polyisotopic elements. Methodical approaches have been considered for the quantitative determination of the isotope composition of an element included in mono- and polyisotopic molecules. A possibility of the equally probable (homogeneous) and non-equally probable (non-homogeneous) distribution of isotopes of a polyisotopic element, the atoms of which have different positions in the molecule of polyisotopomer, has been shown. Factors disturbing the homogeneous distribution of isotopes of the element in the polyisotopomer pool have been revealed. When a polyisotopomer is involved in a mass-dependent process or reaction, the homogeneity of isotope distribution of the element is disturbed both in the residual and newly formed pools of polyisotopomer. By the example of CO 2 (polyisotopomer by oxygen) it has been shown that one can judge of the history of the analyzed pool formation by distribution of oxygen isotopes within this pool. The isotope content in the oxygen sites of polyisotopomer is a diagnostic feature of CO 2 involvement in the efflux from a reservoir or influx to the analyzed reservoir from an external source. (author)

  4. Gene Pools and the Genetic Architecture of Domesticated Cowpea

    Directory of Open Access Journals (Sweden)

    Bao-Lam Huynh

    2013-11-01

    Full Text Available Cowpea [ (L. Walp.] is a major tropical legume crop grown in warm to hot areas throughout the world and especially important to the people of sub-Saharan Africa where the crop was domesticated. To date, relatively little is understood about its domestication origins and patterns of genetic variation. In this study, a worldwide collection of cowpea landraces and African ancestral wild cowpea was genotyped with more than 1200 single nucleotide polymorphism markers. Bayesian inference revealed the presence of two major gene pools in cultivated cowpea in Africa. Landraces from gene pool 1 are mostly distributed in western Africa while the majority of gene pool 2 are located in eastern Africa. Each gene pool is most closely related to wild cowpea in the same geographic region, indicating divergent domestication processes leading to the formation of two gene pools. The total genetic variation within landraces from countries outside Africa was slightly greater than within African landraces. Accessions from Asia and Europe were more related to those from western Africa while accessions from the Americas appeared more closely related to those from eastern Africa. This delineation of cowpea germplasm into groups of genetic relatedness will be valuable for guiding introgression efforts in breeding programs and for improving the efficiency of germplasm management.

  5. Health impact of disinfection by-products in swimming pools

    Directory of Open Access Journals (Sweden)

    Cristina M. Villanueva

    2012-12-01

    Full Text Available This article is focused on the epidemiological evidence on the health impacts related to disinfection by-products (DBPs in swimming pools, which is a chemical hazard generated as an undesired consequence to reduce the microbial pathogens. Specific DBPs are carcinogenic, fetotoxic and/or irritant to the airways according to experimental studies. Epidemiological evidence shows that swimming in pools during pregnancy is not associated with an increased risk of reproductive outcomes. An epidemiological study suggested an increased risk of bladder cancer with swimming pool attendance, although evidence is inconclusive. A higher prevalence of respiratory symptoms including asthma is found among swimming pool workers and elite swimmers, although the causality of this association is unclear. The body of evidence in children indicates that asthma is not increased by swimming pool attendance. Overall, the available knowledge suggests that the health benefits of swimming outweigh the potential health risks of chemical contamination. However, the positive effects of swimming should be enhanced by minimising potential risks.

  6. Neutron transmission through crystalline Fe

    International Nuclear Information System (INIS)

    Adib, M.; Habib, N.; Kilany, M.; El-Mesiry, M.S.

    2004-01-01

    The neutron transmission through crystalline Fe has been calculated for neutron energies in the range 10 4 < E<10 eV using an additive formula. The formula permits calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-section as a function of temperature and crystalline form. The obtained agreement between the calculated values and available experimental ones justifies the applicability of the used formula. A feasibility study on using poly-crystalline Fe as a cold neutron filter and a large Fe single crystal as a thermal one is given

  7. Evaluation of Total Coliform, Fecal Coliform and Residual Chlorine in Swimming Pools in Kermanshah on the Season, the type of Pool, Disinfection System and Source of Water Supply in the during of three years (2010-2012

    Directory of Open Access Journals (Sweden)

    K SHarafi

    2014-11-01

    From the results , although the pools of water quality parameters has been studied in almost ideal But in summer, especially on a female pools and pools with wells water supply source than other pools , to be more oversight .

  8. The logical underpinnings and benefits of pooled pharmaceutical procurement: a pragmatic role for our public institutions?

    Science.gov (United States)

    Huff-Rousselle, Maggie

    2012-11-01

    Multi-national pharmaceutical companies have long operated across national boundaries, and exercised significant leverage because of the breadth and depth of their market control. The goals of public health can be better served by redressing the imbalance in market leverage between supply and demand. Consolidation of purchasing power across borders, as well as within countries across organizational entities, is one means to addressing this imbalance. In those existing pooled procurement models that consolidate purchasing across national boundaries, benefits have included: 1) reductions in unit purchase prices; 2) improved quality assurance; 3) reduction or elimination of procurement corruption; 4) rationalized choice through better-informed selection and standardization; 5) reduction of operating costs and administrative burden; 6) increased equity between members; 7) augmented practical utility in the role of the host institutions (regional or international) administering the system; and finally, 8) increased access to essential medical products within each participating country. Many barriers to implementation of a multi-country pooled procurement system are eliminated when the mechanism is established within a regional or international institution, especially where participating countries are viewed (and view themselves) as clients/members of the institution, so that they have some sense of ownership over the procurement mechanism. This review article is based on two literature reviews, conducted between 2007 and 2009 (including publications from 1996 through 2009), and interviews with key informants. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Effectiveness of FeEDDHA, FeEDDHMA, and FeHBED in Preventing Iron-Deficiency Chlorosis in Soybean

    NARCIS (Netherlands)

    Bin, Levi M.; Weng, Liping; Bugter, Marcel H.J.

    2016-01-01

    The performance of FeHBED in preventing Fe deficiency chlorosis in soybean (Glycine max (L.) Merr.) in comparison to FeEDDHA and FeEDDHMA was studied, as well as the importance of the ortho-ortho and ortho-para/rest isomers in defining the performance. To this end, chlorophyll production (SPAD),

  10. Remote maintenance considerations for swimming pool tokamak reactor

    International Nuclear Information System (INIS)

    Niikura, S.; Yamada, M.; Kasai, M.

    1983-01-01

    Swimming Pool Tokamak Reactor (SPTR) is one of the candidate devices which are expected to demonstrate physical and engineering feasibility for fusion power reactors. In SPTR, water shield is adopted instead of solid shield structures. Among the advantages of SPTR are, from viewpoint of remote maintenance, small handling weight and high space availability between TF coils and a vacuum vessel. On the other hand, high dose rate during reactor repair and adverse effects on remote maintenance equipment by the shielding water might be the disadvantage of SPTR, where it is assumed that the shielding water is drained during reactor repair. Since the design of SPTR is still at the preliminary stage, for remote maintenance, much effort has been directed to clarification of design conditions such as environment and handling weight. As for the remote maintenance system concepts, studies have been focussed on those for a vacuum vessel and its internal structure (blanket, divertor and protection walls) expected to be repaired more frequently. The vacuum vessel assembly is divided into 21 sectors and number of TF coils is 14. A pair of TF coils are connected with each other by antitorque beams on the whole side surface. Vacuum vessel cassettes and associated blanket, divertor and protection walls are replaced through seven windows between TF coils pairs. Therefore each vacuum vessel cassette is required moving mechanisms in toroidal and radial directions. Options for slide mechanisms are wheels, balls, rollers and water bearings. Options for driving the cassette are self-driving by hydraulic motors and external driving by rack-pinion, wires or specific vehicles. As a result of studies, the moving mechanism with wheels and hydraulic motors has been selected for the reference design, and the system with water bearings and rack-pinion as an alternative. Furthermore typical concepts have been obtained for remote maintenance equipment such as wall-mounted manipulators, tools for

  11. Prediction of pool void fraction by new drift flux correlation

    International Nuclear Information System (INIS)

    Kataoka, I.; Ishii, M.

    1986-06-01

    A void fraction for a bubbling or boiling pool system is one of the important parameters in analyzing heat and mass transfer processes. Using the drift flux formulation, correlations for the pool void fraction have been developed in collaboration with a large number of experimental data. It has been found that the drift velocity in a pool system depends upon vessel diameter, system pressure, gas flux and fluid physical properties. The results show that the relative velocity and void fraction can be quite different from those predicted by conventional correlations. In terms of the rise velocity, four different regimes are identified. These are bubbly, churn-turbulent, slug and cap bubble regimes. The present correlations are shown to agree with the experimental data over wide ranges of parameters such as vessel diameter, system pressure, gas flux and physical properties. 39 refs., 41 figs

  12. Models for Pooled Time-Series Cross-Section Data

    Directory of Open Access Journals (Sweden)

    Lawrence E Raffalovich

    2015-07-01

    Full Text Available Several models are available for the analysis of pooled time-series cross-section (TSCS data, defined as “repeated observations on fixed units” (Beck and Katz 1995. In this paper, we run the following models: (1 a completely pooled model, (2 fixed effects models, and (3 multi-level/hierarchical linear models. To illustrate these models, we use a Generalized Least Squares (GLS estimator with cross-section weights and panel-corrected standard errors (with EViews 8 on the cross-national homicide trends data of forty countries from 1950 to 2005, which we source from published research (Messner et al. 2011. We describe and discuss the similarities and differences between the models, and what information each can contribute to help answer substantive research questions. We conclude with a discussion of how the models we present may help to mitigate validity threats inherent in pooled time-series cross-section data analysis.

  13. Lin28a regulates germ cell pool size and fertility

    Science.gov (United States)

    Shinoda, Gen; de Soysa, T. Yvanka; Seligson, Marc T.; Yabuuchi, Akiko; Fujiwara, Yuko; Huang, Pei Yi; Hagan, John P.; Gregory, Richard I.; Moss, Eric G.; Daley, George Q.

    2013-01-01

    Overexpression of LIN28A is associated with human germ cell tumors and promotes primordial germ cell (PGC) development from embryonic stem cells in vitro and in chimeric mice. Knockdown of Lin28a inhibits PGC development in vitro, but how constitutional Lin28a deficiency affects the mammalian reproductive system in vivo remains unknown. Here, we generated Lin28a knockout (KO) mice and found that Lin28a deficiency compromises the size of the germ cell pool in both males and females by affecting PGC proliferation during embryogenesis. Interestingly however, in Lin28a KO males the germ cell pool partially recovers during postnatal expansion, while fertility remains impaired in both males and females mated to wild type mice. Embryonic overexpression of let-7, a microRNA negatively regulated by Lin28a, reduces the germ cell pool, corroborating the role of the Lin28a/let-7 axis in regulating the germ lineage. PMID:23378032

  14. Safety analysis of a pool Genesis II irradiator

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de A.

    2011-01-01

    The Genesis II Irradiator manufactured by GRAT * STAR Inc. (USA) is a category III gamma irradiator in which the sealed source is contained in a water filled storage pool and is shielded permanently, i.e. the material has to move down to the source. Even though the pool is 5.6 m deep, what would happen if the water level lowered? There are a series of safety devices that will avoid this situation and calculations show that the water level has to be very low in order to deliver a significant dose; moreover, only in case a person remains at the border of the pool for a long time this would be risky. In conclusion, it is practically impossible for someone to be exposed to radiation from a Genesis II Irradiator source. (author)

  15. Core disruptive accident and recriticality analysis with FX2-POOL

    International Nuclear Information System (INIS)

    Abramson, P.B.

    1976-01-01

    The current state of development of FX2-POOL, a two-dimensional hydrodynamic, thermodynamic and neutronic scoping model for Hypothetical Core Disruptive Accident analysis is described. Checkout comparisons to VENUS for prompt burst conditions were good. Use of FX2-POOL to examine the importance of fuel to steel heat transfer during a prompt burst indicates that heat transfer plays no important role on that time scale. Scoping studies of material thermohydrodynamics for about 20 to 30 milliseconds following the prompt burst indicate that heat transfer is important on the time scale necessary for the CDA bubble to grow to the size of the original core. Preliminary results are presented for energetics of boiling fuel steel pools which are forced recritical by local surface pressurization

  16. CFD modeling of pool swell during large break LOCA

    International Nuclear Information System (INIS)

    Yan, Jin; Bolger, Francis; Li, Guangjun; Mintz, Saul; Pappone, Daniel

    2009-01-01

    GE had conducted a series of one-third scale three-vent air tests in support the horizontal vent pressure suppression system used in Mark III containment design for General Electric BWR plants. During the test, the air-water interface has been tracked by conductivity probes. There are many pressure monitors inside the test rig. The purpose of the test was to provide a basis for the pool swell load definition for the Mark III containment. In this paper, a transient 3-Dimensional CFD model of the one-third scale Mark III suppression pool swell process is constructed. The Volume of Fluid (VOF) multiphase model is used to explicitly track the interface between the water liquid and the air. The CFD results such as flow velocity, pressure, interface locations are compared to those from the test. Through the comparisons, a technical approach to numerically model the pool swell phenomenon is established and benchmarked. (author)

  17. Analysis of radiation shields of BNPP spent fuel pool

    International Nuclear Information System (INIS)

    Ayoobian, N.; Hadad, K.; Nematollahi, M. R.

    2007-01-01

    Radioactive protection is one of the most important subjects in nuclear power plants safety. Analysis of BNPP spent fuel pool shielding , as a main source of energetic γ-rays was the main goal of this project. Firstly, we simulated the reactor core using WIMSD-4 neutronic code and the amount of fission product in the fuel assembly (FA) was calculated during the reactor operation. Then, by obtaining the results from the previous calculation and by using MCNP4C nuclear code , the intensity of γ-rays was obtained in layers of spent fuel pool shields. The results have shown that no significant γ-rays passed through these shields. Finally, an accident and resulting exposure dose above the pool was analyzed

  18. Insertion sequences enrichment in extreme Red sea brine pool vent

    KAUST Repository

    Elbehery, Ali H. A.

    2016-12-03

    Mobile genetic elements are major agents of genome diversification and evolution. Limited studies addressed their characteristics, including abundance, and role in extreme habitats. One of the rare natural habitats exposed to multiple-extreme conditions, including high temperature, salinity and concentration of heavy metals, are the Red Sea brine pools. We assessed the abundance and distribution of different mobile genetic elements in four Red Sea brine pools including the world’s largest known multiple-extreme deep-sea environment, the Red Sea Atlantis II Deep. We report a gradient in the abundance of mobile genetic elements, dramatically increasing in the harshest environment of the pool. Additionally, we identified a strong association between the abundance of insertion sequences and extreme conditions, being highest in the harshest and deepest layer of the Red Sea Atlantis II Deep. Our comparative analyses of mobile genetic elements in secluded, extreme and relatively non-extreme environments, suggest that insertion sequences predominantly contribute to polyextremophiles genome plasticity.

  19. Spent nuclear fuel storage pool thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Gay, R.R.

    1984-01-01

    Storage methods and requirements for spent nuclear fuel at U.S. commercial light water reactors are reviewed in Section 1. Methods of increasing current at-reactor storage capabilities are also outlined. In Section 2 the development of analytical methods for the thermal-hydraulic analysis of spent fuel pools is chronicled, leading up to a discussion of the GFLOW code which is described in Section 3. In Section 4 the verification of GFLOW by comparisons of the code's predictions to experimental data taken inside the fuel storage pool at the Maine Yankee nuclear power plant is presented. The predictions of GFLOW using 72, 224, and 1584 node models of the storage pool are compared to each other and to the experimental data. An example of thermal licensing analysis for Maine Yankee using the GFLOW code is given in Section 5. The GFLOW licensing analysis is compared to previous licensing analysis performed by Yankee Atomic using the RELAP-4 computer code

  20. High efficiency pool filtering systems utilising variable frequency drives

    Energy Technology Data Exchange (ETDEWEB)

    Hameiri, Z.; Sproul, A.B. [School of Photovoltaic and Renewable Energy Engineering, UNSW, Sydney, NSW 2052 (Australia); Spooner, T. [School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia)

    2009-02-15

    Over 1 year, private swimming pools in Australia will typically consume 1680 GWh of electricity, producing 2130 kt of CO{sub 2}. Redesigning a pool's filtration system and using it more efficiently can reduce the energy use, and hence the CO{sub 2} production, by a significant amount. This paper describes experimental measurements carried out on a new design of pool pump system. Initial experiments using a variable frequency drive (VFD) with a standard, single phase pump/motor system have achieved energy savings of 40%. Utilising a VFD and a three phase pump/motor energy savings of 61% have been achieved, without degrading the system performance. (author)

  1. Analyzing data distribution on disk pools for dCache

    Energy Technology Data Exchange (ETDEWEB)

    Halstenberg, S; Jung, C; Ressmann, D [Forschungszentrum Karlsruhe, Steinbuch Centre for Computing, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2010-04-01

    Most Tier-1 centers of LHC Computing Grid are using dCache as their storage system. dCache uses a cost model incorporating CPU and space costs for the distribution of data on its disk pools. Storage resources at Tier-1 centers are usually upgraded once or twice a year according to given milestones. One of the effects of this procedure is the accumulation of heterogeneous hardware resources. For a dCache system, a heterogeneous set of disk pools complicates the process of weighting CPU and space costs for an efficient distribution of data. In order to evaluate the data distribution on the disk pools, the distribution is simulated in Java. The results are discussed and suggestions for improving the weight scheme are given.

  2. Inferring local ecological processes amid species pool influences

    DEFF Research Database (Denmark)

    Lessard, Jean-Philippe; Belmaker, Jonathan; Myers, Jonathan A.

    2012-01-01

    studies, null models of community structure, and ecologically explicit definitions of the species pool as a means to compare predominant ecological processes among regions. By uniting concepts and tools from community ecology and macroecology, this approach might facilitate synthesis and resolve many......Resolving contingencies in community ecology requires comparative studies of local communities along broad-scale environmental gradients and in different biogeographic regions. However, comparisons of local ecological processes among regions require a synthetic understanding of how the species pool...... of potential community members influences the structure of ecological communities. Here, we outline an integrative approach for quantifying local ecological processes while explicitly accounting for species pool influences. Specifically, we highlight the utility of combining geographically replicated local...

  3. CAREM 25: Suppression pool cooling and purification system

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Patrignani, Alberto; Vindrola, Carlos; Palmerio, Hector D.; Quiroz, Horacio; Ramilo, Lucia B.

    2000-01-01

    The suppression pool cooling and purification system has the following main functions: purify and cool water from the suppression pool, cool and send water to the residual heat extraction system, and transfer water to the fuel element transference channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the suppression pool to the spray network, thus cooling and reducing pressure in the primary containment. The system has been designed in accordance with the requirements of the following standards: ANSI/ANS 52.1; ANSI/ANS 57.2; ANSI/ANS 56.2; ANSI/ANS 59.1; ANSI/ANS 58.3; ANSI/ANS 58.9; and ANSI/ANS 56.5. The design of the system fulfils all the assigned functions. (author)

  4. CAREM-25. Suppression Pool Cooling and Purification System

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Palmerio, D.; Patrignani, A.; Quiroz, H.; Ramilo, L.; Vindrola, C.

    2000-01-01

    The Suppression Pool Cooling and Purification System has the following main functions: purify and cool water from the Suppression Pool, cool and send water to the Residual Heat Extraction System, and transfer water to the Fuel Element Transference Channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the Suppression Pool to the spray network, thus cooling and reducing pressure in the primary containment.The system has been designed in accordance with the requirements of the following standards ANSI/ANS 52.1 [1], ANSI/ANS 57.2 [2], ANSI/ANS 56.2 [3], ANSI/ANS 59.1 [4] ANSI/ANS 58.3 [5], ANSI/ANS 58.9 [6], and ANSI/ANS 56.5 [7]. The design of the system fulfils all the assigned functions

  5. Analysis of the loss of pool cooling accident in a PWR spent fuel pool with MAAP5

    International Nuclear Information System (INIS)

    Wu, Xiaoli; Li, Wei; Zhang, Yapei; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng

    2014-01-01

    Highlights: • A PWR spent fuel pool was modeled by using MAAP5. • Loss of pool cooling severe accident scenarios were studied. • Loss of pool cooling accidents with two mitigation measures were analyzed. - Abstract: The Fukushima Daiichi nuclear accident shows that it is necessary to study potential severe accidents and corresponding mitigation measures for the spent fuel pool (SFP) of a nuclear power plant (NPP). This paper presents the analysis of loss of pool cooling accident scenarios and the discussion of mitigation measures for the SFP at a pressurized water reactor (PWR) NPP with the MAAP5 code. Analysis of uncompensated loss of water due to the loss of pool cooling with different initial pool water levels of 12.2 m (designated as a reference case) and 10.7 m have been performed based on a MAAP5 input model. Scenarios of the accident such as overheating of uncovered fuel assemblies, oxidation of claddings and hydrogen generation, loss of intactness of fuel rod claddings, and release of radioactive fission products were predicted with the assumption that mitigation measures were unavailable. The results covered a broad spectrum of severe accident evaluations in the SFP. Furthermore, as important mitigation measures, the effects of recovering the SFP cooling system and makeup water in SFP on the accident progressions have also been investigated respectively based on the events of pool water boiling and spent fuels uncovery. Based upon the reference case, three cases with the recovery of SFP cooling system and three other cases with makeup water in SFP have been studied. The results showed that, severe accident might happen if SFP cooling system was not restored timely before the spent fuels started to become uncovered; spent fuels could be completely submerged and severe accident might be avoided if SFP makeup water system provided water with a mass flow rate larger than the average evaporation rate defined as the division of pool water mass above the

  6. Photoionization of FE3+ Ions

    International Nuclear Information System (INIS)

    Ovchinnikov, O.; Schlachter, F.

    2003-01-01

    Photoionization of Fe3+ ions was studied for the first time using synchrotron radiation from the Advanced Light Source (ALS) and the merged-beams technique. Fe3+ ions were successfully produced using ferrocene in an electron cyclotron resonance ion source (ECR). The measured yield of Fe4+ photoions as a function of photon energy revealed the presence of resonances that correspond to excitation of autoionizing states. These resonances are superimposed upon the photoion yield produced by direct photoionization, which is a smooth, slowly decreasing function of energy. The spectra for the photoionization of Fe3+ will be analyzed and compared with theory. The data collected will also serve to test models for the propagation of light through ionized matter.

  7. Temperature dependent fission product removal efficiency due to pool scrubbing

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Shunsuke, E-mail: suchida@iae.or.jp [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Hanamoto, Yukio [KAKEN, Inc., 1044, Hori-machi, Mito 310-0903 (Japan); Osakabe, Masahiro [Tokyo University of Marine Science & Technology, Koutou-ku, Tokyo 135-8533 (Japan); Fujikawa, Masahiro [Japan Broadcasting Corporation, 2-2-1, Jinnan, Shibuya-ku, Tokyo 150-8001 (Japan)

    2016-03-15

    Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the

  8. Temperature dependent fission product removal efficiency due to pool scrubbing

    International Nuclear Information System (INIS)

    Uchida, Shunsuke; Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki; Hanamoto, Yukio; Osakabe, Masahiro; Fujikawa, Masahiro

    2016-01-01

    Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the

  9. Evaluation of Fe(II) oxidation at an acid mine drainage site using laboratory-scale reactors

    Science.gov (United States)

    Brown, Juliana; Burgos, William

    2010-05-01

    Acid mine drainage (AMD) is a severe environmental threat to the Appalachian region of the Eastern United States. The Susquehanna and Potomac River basins of Pennsylvania drain to the Chesapeake Bay, which is heavily polluted by acidity and metals from AMD. This study attempted to unravel the complex relationships between AMD geochemistry, microbial communities, hydrodynamic conditions, and the mineral precipitates for low-pH Fe mounds formed downstream of deep mine discharges, such as Lower Red Eyes in Somerset County, PA, USA. This site is contaminated with high concentrations of Fe (550 mg/L), Mn (115 mg/L), and other trace metals. At the site 95% of dissolved Fe(II) and 56% of total dissolved Fe is removed without treatment, across the mound, but there is no change in the concentration of trace metals. Fe(III) oxides were collected across the Red Eyes Fe mound and precipitates were analyzed by X-ray diffraction, electron microscopy and elemental analysis. Schwertmannite was the dominant mineral phase with traces of goethite. The precipitates also contained minor amounts of Al2O3, MgO,and P2O5. Laboratory flow-through reactors were constructed to quantify Fe(II) oxidation and Fe removal over time at terrace and pool depositional facies. Conditions such as residence time, number of reactors in sequence and water column height were varied to determine optimal conditions for Fe removal. Reactors with sediments collected from an upstream terrace oxidized more than 50% of dissolved Fe(II) at a ten hour residence time, while upstream pool sediments only oxidized 40% of dissolved Fe(II). Downstream terrace and pool sediments were only capable of oxidizing 25% and 20% of Fe(II), respectively. Fe(II) oxidation rates measured in the reactors were determined to be between 3.99 x 10-8and 1.94 x 10-7mol L-1s-1. The sediments were not as efficient for total dissolved Fe removal and only 25% was removed under optimal conditions. The removal efficiency for all sediments

  10. Sodium-water reaction in double pool LMFBR, (5)

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Kumagai, Hiromichi; Nishi, Yoshihisa; Uotani, Masaki

    1990-01-01

    Experiments were conducted using a 1/5 scale model of the Double Pool in order to evaluate a pressure rise caused by a large scale sodium-water reaction. The experiments were focused on the pressure rise caused by the piston motion of liquid sodium. It appeared from the results that the magnitude of this pressure rise depends on the depth of reaction point, and that a pressure rise more than 1 MPa would arise in the real Double Pool plant. A new design of steam generator is proposed to mitigate the pressure rise. (author)

  11. The CERN Electronics Pool moves to Building 13

    CERN Multimedia

    PH Department

    2010-01-01

    After 32 years in Building 4 R‐050, the CERN Electronics Pool will re‐open in Building 13 R009 on Monday 13 December at 10:00 As of this date, you will be able to come and choose the instruments you want: oscilloscopes and other measurement instruments, low and high voltage power supplies, modular instrumentation, etc. Please do not hesitate to consult the catalogue and give us any input you may have. The CERN Electronics Pool operates on a self-service basis (with a CERN budget code) and is available for any help you may need.

  12. Carbon dynamics in peatland pool systems: the role of light

    Science.gov (United States)

    Pickard, Amy; Heal, Kate; McLeod, Andy; Dinsmore, Kerry

    2016-04-01

    Open-water pools are widespread in peatlands and are considered to represent biogeochemical hotspots within the peatland landscape. However the contribution of pool systems to wider peatland C cycling has not been quantified fully and there is a lack of knowledge of the role of photochemical processes in such environments. In this study, light exposure experiments were conducted in two contrasting pools to test the reactivity of aquatic C. The first study site was located at Cross Lochs (CL), Forsinard, in the Flow Country of Northern Scotland, in a 412 m2 pool characterised by low dissolved organic carbon (DOC) concentrations (˜15 mg C L-1). The second site was located at Red Moss of Balerno (RM), a raised bog in central Scotland, in a 48 m2 pool with high DOC concentrations (˜35 mg C L-1). Experiments took place over 9 days in situ at each pool in mid-summer 2015, with 500 mL water samples contained in bags transparent to sunlight and in opaque control bags. After field exposure, optical, chemical and stable C isotope analyses were conducted on the samples. Significant differences in biogeochemical cycling of DOC were detected between the two systems, with DOC losses as a percentage of the total C pool 15% higher at RM than at CL after light exposure. The mean DOC concentration of light exposed samples at RM declined steeply initially, with 83% observed DOC degradation occurring by day 3 of the experiment. Total losses of 7.9 mg DOC L-1were observed in light exposed samples at RM, along with decreasing E4:E6 ratios, suggesting that material remaining at the end of the experiment was humified. Depletion of DOC was positively correlated with production of CO2 at both sites, with concentrations of up to 4.3 mg CO2-C L-1 recorded at RM. Stable C isotope signatures at both sites were altered under light treatment, as demonstrated by the production of enriched δ13C-DOC (+0.46 ‰ relative to opaque bags) and depleted δ13C-DIC (-0.97 ‰ relative to opaque bags) at

  13. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    2008-05-29

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.  Created: 5/29/2008 by Emerging Infectious Diseases.   Date Released: 5/29/2008.

  14. CoFeRh alloys

    Energy Technology Data Exchange (ETDEWEB)

    Tabakovic, Ibro [Seagate Technology, Research and Development, Bloomington, MN 55435 (United States)], E-mail: ibro.m.tabakovic@seagate.com; Qiu Jiaoming; Riemer, Steve; Sun Ming; Vas' ko, Vlad; Kief, Mark [Seagate Technology, Research and Development, Bloomington, MN 55435 (United States)

    2008-01-01

    The electrochemical behavior of Rh(III) species in CoFe solution containing RhCl{sub 3}, NH{sub 4}Cl, H{sub 3}BO{sub 3}, CoSO{sub 4}, FeSO{sub 4}, saccharin, and NaLS (Na lauryl sulfate) has been investigated. The electrochemistry of Rh(III) species is influenced by each of the compounds present in CoFe plating solution, but especially by addition of saccharin and H{sub 3}BO{sub 3} to the RhCl{sub 3}-NH{sub 4}Cl solution. The nucleation and growth of Rh on GC (glassy carbon), Ru, and Cu electrodes from NH{sub 4}Cl solution was studied using the potentiostatic current-transient methods. The results support a predominantly progressive nucleation of Rh on all three-electrode surfaces. The nucleation kinetic parameters ANo (steady state nucleation rate) and Ns (saturation nuclear number density) were found to vary with potential and are electrode-dependent in order: GC > Ru{approx}Cu. The electrodeposited Rh films obtained from NH{sub 4}Cl solution and nonmagnetic CoFeRh film obtained from CoFe solution were characterized in terms of the following properties: morphology, surface roughness, crystal structure and chemical composition. The origin of light elements found in Rh and CoFeRh films (O, Cl, S, C, N) was discussed.

  15. CoFeRh alloys

    International Nuclear Information System (INIS)

    Tabakovic, Ibro; Qiu Jiaoming; Riemer, Steve; Sun Ming; Vas'ko, Vlad; Kief, Mark

    2008-01-01

    The electrochemical behavior of Rh(III) species in CoFe solution containing RhCl 3 , NH 4 Cl, H 3 BO 3 , CoSO 4 , FeSO 4 , saccharin, and NaLS (Na lauryl sulfate) has been investigated. The electrochemistry of Rh(III) species is influenced by each of the compounds present in CoFe plating solution, but especially by addition of saccharin and H 3 BO 3 to the RhCl 3 -NH 4 Cl solution. The nucleation and growth of Rh on GC (glassy carbon), Ru, and Cu electrodes from NH 4 Cl solution was studied using the potentiostatic current-transient methods. The results support a predominantly progressive nucleation of Rh on all three-electrode surfaces. The nucleation kinetic parameters ANo (steady state nucleation rate) and Ns (saturation nuclear number density) were found to vary with potential and are electrode-dependent in order: GC > Ru∼Cu. The electrodeposited Rh films obtained from NH 4 Cl solution and nonmagnetic CoFeRh film obtained from CoFe solution were characterized in terms of the following properties: morphology, surface roughness, crystal structure and chemical composition. The origin of light elements found in Rh and CoFeRh films (O, Cl, S, C, N) was discussed

  16. Glassy behavior of the Nd sublattice induced by Fe doping in NdFexGa1-xO3

    International Nuclear Information System (INIS)

    Bartolome, F.; Parra-Borderias, M.; Blasco, J.; Bartolome, J.

    2007-01-01

    The evolution of the magnetic ordering of Nd with the Fe content in NdFe x Ga 1-x O 3 is studied by low-temperature specific-heat measurements for x= =0.2. Fe doping creates a distribution of internal fields on Nd, originating a Schottky contribution to the specific heat which is present for x>0. The power law followed by the low-temperature specific heat suggests a glassy behavior for x>=0.1

  17. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  18. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  19. Characteristics of pools used by adult summer steelhead oversummering in the New River, California

    Science.gov (United States)

    Rodney J. Nakamoto

    1994-01-01

    Abstract - I assessed characteristics of pools used by oversummering adults of summer steelhead Oncorhynchus mykiss between July and October 1991 in the New River, northwestern California. Most fish occupied channel confluence pools and other pools of moderate size (200-1,200 m 2); these pools had less than 35% substrate embeddedness and mean water depths of about 1.0...

  20. Chemical synthesis, phase transformation and magnetic proprieties of FePt and FePd nanoparticles

    International Nuclear Information System (INIS)

    Delattre, Anastasia

    2010-01-01

    This work aims at understanding the chemical synthesis of FePt and FePd nanoparticles (NPs), and at exploring how to implement the phase transformation from the chemically disordered to the L10 phase, without coalescence. Using hexadecanenitrile instead of oleylamine, we obtain NPs with a more homogenous internal composition, instead of core-shell NPs. Through a systematic study (designed experiment relying on Taguchi tables), we developed the FePd synthesis, while evidencing the role of each ligand and of the reductor. To induce the crystalline phase transformation while avoiding coalescence, we explored two ways. In the first one, atomic vacancies are introduced in the NPs through light ion irradiation, atomic mobility being ensured by annealing at moderate temperature (300 C). As a result, the blocking temperature is multiplied by 4, due to anisotropy enhancement. However, strong chemical ordering in the L10 phase cannot be achieved. The second approach relies on the dispersion of the NPs in a salt (NaCl) matrix, prior to annealing at 700 C: high chemical ordering is achieved, and the blocking temperature is beyond 400 C. We then developed a single-step process to remove the salt by dissolution in water and to re-disperse NPs in stable aqueous or organics solutions. These high magnetic anisotropy NPs are then readily available for further chemical or manipulation steps, with applied perspectives in areas such as data storage, or biology. (author)