WorldWideScience

Sample records for internal bone fixation

  1. Autologous bone graft versus demineralized bone matrix in internal fixation of ununited long bones.

    Science.gov (United States)

    Pieske, Oliver; Wittmann, Alexandra; Zaspel, Johannes; Löffler, Thomas; Rubenbauer, Bianka; Trentzsch, Heiko; Piltz, Stefan

    2009-12-15

    Non-unions are severe complications in orthopaedic trauma care and occur in 10% of all fractures. The golden standard for the treatment of ununited fractures includes open reduction and internal fixation (ORIF) as well as augmentation with autologous-bone-grafting. However, there is morbidity associated with the bone-graft donor site and some patients offer limited quantity or quality of autologous-bone graft material. Since allogene bone-grafts are introduced on the market, this comparative study aims to evaluate healing characteristics of ununited bones treated with ORIF combined with either iliac-crest-autologous-bone-grafting (ICABG) or demineralized-bone-matrix (DBM). From 2000 to 2006 out of sixty-two consecutive patients with non-unions presenting at our Level I Trauma Center, twenty patients had ununited diaphyseal fractures of long bones and were treated by ORIF combined either by ICABG- (n = 10) or DBM-augmentation (n = 10). At the time of index-operation, patients of the DBM-group had a higher level of comorbidity (ASA-value: p = 0.014). Mean duration of follow-up was 56.6 months (ICABG-group) and 41.2 months (DBM-group). All patients were clinically and radiographically assessed and adverse effects related to bone grafting were documented. The results showed that two non-unions augmented with ICABG failed osseous healing (20%) whereas all non-unions grafted by DBM showed successful consolidation during the first year after the index operation (p = 0.146). No early complications were documented in both groups but two patients of the ICABG-group suffered long-term problems at the donor site (20%) (p = 0.146). Pain intensity were comparable in both groups (p = 0.326). However, patients treated with DBM were more satisfied with the surgical procedure (p = 0.031). With the use of DBM, the costs for augmentation of the non-union-site are more expensive compared to ICABG (calculated difference: 160 euro/case). Nevertheless, this study demonstrated that the

  2. Influence of different methods of internal bone fixation on characteristics of bone callus in experimental animals

    Directory of Open Access Journals (Sweden)

    Gajdobranski Đorđe

    2014-01-01

    Full Text Available Introduction. Correct choice of osteosynthesis method is a very important factor in providing the optimal conditions for appropriate healing of the fracture. There are still disagreements about the method of stabilization of some long bone fractures. Critically observed, no method of fracture fixation is ideal. Each osteosynthesis method has both advantages and weaknesses. Objective. The objective of this study was to compare the results of the experimental application of three different internal fixation methods: plate fixation, intramedullary nail fixation and self-dynamisable internal fixator (SIF. Methods. A series of 30 animals were used (Lepus cuniculus as experimental animals, divided into three groups of ten animals each. Femoral diaphysis of each animal was osteotomized and fixed with one of three implants. Ten weeks later all animals were sacrificed and each specimen underwent histological and biomechanical testing. Results. Histology showed that the healing process with SIF was more complete and bone callus was more mature in comparison to other two methods. During biomechanical investigation (computerized bending stress test, it was documented with high statistical significance that using SIF led to stronger healing ten weeks after the operation. Conclusion. According to the results obtained in this study, it can be concluded that SIF is a suitable method for fracture treatment.

  3. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  4. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis.

    Science.gov (United States)

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo

    2017-01-01

    To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.

  5. Closed reduction, internal fixation with quadratus femoris muscle pedicle bone grafting in displaced femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Chaudhuri Sibaji

    2008-01-01

    Full Text Available Background: Management of femoral neck fracture is still considered as an unsolved problem. It is more evident in displaced fractures where this fracture is considered as some sort of vascular insult to the head of the femur. We have used closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting in fresh displaced femoral neck fractures. Materials and Methods: From April 1996 to December 2004 we operated 73 consecutive patients of displaced femoral neck fracture in the age group of 24 to 81 years, mean age being 54.6 years. The patients were operated within one week of injury, the mean delay being 3.6 days. Closed reduction internal fixation along with quadratus femoris muscle pedicle bone grafting was done in all cases. They were followed up for an average period of 5.6 years (range 2-11 years. Results: Results were assessed according to modified Harris Hip Scoring system and found to be excellent in 53, good in 12, fair in six and poor in two patients. Bony union occurred in 68 cases, no patient developed avascular necrosis (AVN till date. Conclusion: For fresh displaced femoral neck fracture in physiologically active patients closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting is a suitable option to secure union and prevent development of AVN.

  6. Treatment of Unicameral Bone Cysts of the Proximal Femur With Internal Fixation Lessens the Risk of Additional Surgery.

    Science.gov (United States)

    Wilke, Benjamin; Houdek, Matthew; Rao, Rameshwar R; Caird, Michelle S; Larson, A Noelle; Milbrandt, Todd

    2017-09-01

    Little data exist to guide the treatment of unicameral bone cysts in the proximal femur. Methods of treatment include corticosteroid injections, curettage and bone grafting, and internal fixation. The authors completed a multi-institutional, retrospective review to evaluate their experience with proximal femoral unicameral bone cysts. They posed the following questions: (1) Does internal fixation reduce the risk of further procedures for the treatment of a unicameral bone cyst? (2) Is radiographic healing faster with internal fixation? Following institutional review board approval, the authors conducted a retrospective review of 36 patients treated for a unicameral bone cyst of the proximal femur at their institutions between 1974 and 2014. Medical records and radiographs were reviewed to identify patient demographics and treatment outcomes. Tumor locations included femoral neck (n=13), intertrochanteric (n=16), and subtrochanteric (n=7). Initial treatment included steroid injection (n=2), curettage and bone grafting (n=9), and internal fixation with curettage and bone grafting (n=25). Mean time was 9 months to radiographic healing and 15 months to return to full activity. The number of patients requiring additional surgeries was increased among those who did not undergo internal fixation. There was no difference in time to radiographic healing. However, time to return to normal activities was reduced if patients had received internal fixation. A significant reduction in additional procedures was observed when patients had been treated with internal fixation. Although this did not influence time to radiographic healing, patients did return to normal activities sooner. Internal fixation should be considered in the treatment of proximal femoral unicameral bone cysts. [Orthopedics. 2017; 40(5):e862-e867.]. Copyright 2017, SLACK Incorporated.

  7. Internal fixation and muscle pedicle bone grafting in femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Gupta A

    2008-01-01

    Full Text Available Background: The treatment of displaced intracapsular femoral neck fracture is still an unsolved problem. Non-union and avascular necrosis are the two main complications of this fracture, especially if patient presents late. Muscle pedicle bone grafting has been advocated to provide additional blood supply. We present analysis of our 32 cases of displaced femoral neck fracture treated by internal fixation and quadratus femoris based muscle pedicle bone grafting. Materials and Methods: Open reduction and internal fixation with muscle pedicle grafting was done in 32 patients. The age of patients varied from 14-62 years (average age 45 years with male to female ratio of 13:3. Twenty-nine fractures were more than three weeks old. All the cases were treated by Meyers′ procedure. The fracture was internally fixed after open reduction and then a muscle pedicle graft was applied. It was supplemented by cancellous bone graft in seven cases. Fixation was done by parallel cancellous lag screws ( n = 19, crossed Garden′s screws ( n = 7, parallel Asnis screws ( n = 5 and Moore′s pin ( n = 1.Quadratus femoris muscle pedicle graft was used in 32 cases. In the initial 12 cases the graft was fixed with circumferential proline sutures, but later, to provide a secure fixation, the graft was fixed with a cancellous screw ( n = 20. Postoperative full weight bearing was deferred to an average of 10 weeks. Results: Union was achieved in 26/29 (89.65% cases which could be followed for an average period of 3.4 years, (2-8.5 years with good functional results and had the ability to squat and sit cross-legged. Results were based on hip rating system given by Salvatti and Wilson. The results were excellent in 15 cases, good in four cases, fair in four cases and poor in six cases. Complications were avascular necrosis ( n = 2, transient foot drop ( n = 2, coxa-vara ( n = 1 and temporary loss of scrotal sensation ( n = 1. Conclusion: Muscle pedicle bone grafting with

  8. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    Science.gov (United States)

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  9. In vitro evaluation of allogeneic bone screws for use in internal fixation of transverse fractures created in proximal sesamoid bones obtained from equine cadavers.

    Science.gov (United States)

    Sasaki, Naoki; Takakuwa, Jun; Yamada, Haruo; Mori, Ryuji

    2010-04-01

    To evaluate effectiveness of allogeneic bone screws and pins for internal fixation of midbody transverse fractures of equine proximal sesamoid bones (PSBs) in vitro. 14 forelimbs from cadavers of 3-year-old Thoroughbreds. Allogeneic cortical bone fragments were collected from the limbs of a male Thoroughbred, and cortical bone screws were prepared from the tissue by use of a precision desktop microlathe programmed with the dimensions of a metal cortical bone screw. A midbody transverse osteotomy of each PSB was performed by use of a bone-shaping oscillating saw and repaired via 1 of 3 internal fixation techniques: 1 allogeneic bone screw with 1 allogeneic bone pin (type I; n = 6 PSBs), 2 allogeneic bone screws (type II; 8), or 1 stainless steel cortical bone screw (control repair; 6). Mechanical tension measurements were obtained by use of a commercially available materials testing system. Mean +/- SD tensile strength (TS) was 668.3 +/- 216.6 N for type I repairs, 854.4 +/- 253.2 N for type II repairs, and 1,150.0 +/- 451.7 N for control repairs. Internal fixation of PSB fractures by the use of allogeneic bone screws and bone pins was successful. Although mean TS of control repairs with stainless steel cortical bone screws was greater than the mean TS of type I and type II repairs, the difference between type II and control repairs was not significant. Allogeneic screws may advance healing and result in fewer complications in a clinical setting.

  10. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    Full Text Available Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8-30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG were excluded. Thus, out of 244 patients, 208 (85.3% untreated nonunion and 36 (14.7% following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN femoral head was found histologically in 135 (54.3% and radiologically in 48 (19.7% patients. The patients were operated by open reduction of fracture

  11. Outcome after open reduction and internal fixation of intraarticular fractures of the calcaneum without the use of bone grafts

    Directory of Open Access Journals (Sweden)

    Pendse Aniruddha

    2006-01-01

    Full Text Available Background: Intraarticular fractures of calcaneum are commenest type of calcaneal fractures. Lots of controversies exist about the ideal management for them. The focus is now shifting on operative management by open reduction and internal fixation for these fractures with or without the use of bone grafts. Method: Thirty intraarticular fractures classified by Essex Lopresti radiological classification, were treated by open reduction and fixation. The patients were followed over a mean period of 30 months (25-40 months. Results: All the fractures united at a mean duration of 14 weeks. 86% patients had excellent functional outcome with one patient having fair and one having poor functional outcome. Conclusion: Open reduction and internal fixation with plate is a good method for treatment of intraarticular fractures of calcaneum to achieve anatomical restoration of articular surface under vision, stable fixation, early mobilization and an option for primary subtalar arthrodesis if deemed necessary.

  12. Radiostrontium clearance and bone formation in response to simulated internal screw fixation

    International Nuclear Information System (INIS)

    Daum, W.J.; Simmons, D.J.; Fenster, R.; Shively, R.A.

    1987-01-01

    Changes in radiostrontium clearance (SrC) and bone formation (tetracycline labeling) were observed in the femurs of skeletally mature dogs following the various operative steps involved in bone screw fixation. Drilling, but not periosteal stripping, produced a small but statistically significant increase in SrC and endosteal bone formation in the distal third of the bone. Strontium clearance values equivalent to those produced by drilling alone were recorded after screw fixation at low or high torque (5 versus 20 inch pounds), as well as by the insertion of loosely fitting stainless steel implants. Bone formation (equals the percentage tetracycline-labeled trabecular bone surfaces) was increased by 30% when SrC values exceeded 3.5 ml/100 g bone/min, and the relationship was linear when SrC values ranged between 1.0 and 7.0 ml/100 g bone/min. The changes in SrC and bone formation one-week after bone screw application are primarily those associated with a response to local trauma caused by drilling

  13. Multiple Rib Nonunion: Open Reduction and Internal Fixation and Iliac Crest Bone Graft Aspirate.

    Science.gov (United States)

    Kaplan, Daniel J; Begly, John; Tejwani, Nirmal

    2017-08-01

    Rib fractures are a common chest injury that can typically be treated nonoperatively. However, a percentage of these will go on to nonunion, either because of unique characteristics of the fracture itself or because of a variety of poor healing factors of the host. If a patient has continued symptomology beyond 3 months, surgeons may consider operative management. Although isolated resection of fibrous scar tissue from the nonunion site may be sufficient in some cases, it may also be necessary to provide additional structural integrity to the rib depending on the extent of the fracture pattern and resection. This goal can be achieved operatively with rib plating and bone grafting to promote healing. This video demonstrates the use of plating in the treatment of rib nonunion. It begins with relevant background information on rib fractures and nonunions, then details the approach, open reduction and internal fixation of 3 ribs using plates and bone graft aspirate. Pearls and pitfalls are included during the surgical technique aspect of the video to both help guide surgeons new to the procedure and provide potentially advantageous technical details to more experienced surgeons.

  14. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    Science.gov (United States)

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  15. Orthopedic infections in equine long bone fractures and arthrodeses treated by internal fixation: 192 cases (1990-2006).

    Science.gov (United States)

    Ahern, Benjamin J; Richardson, Dean W; Boston, Raymond C; Schaer, Thomas P

    2010-07-01

    To determine the rate of postoperative infection (POI) for internal fixation repaired equine long bone fractures and arthrodeses and identify associated risk factors. Case series. Horses (n=192) with fracture repair of the third metacarpal and metatarsal bones, radius, ulna, humerus, tibia, and femur, or arthrodesis with internal fixation. Medical records (1990-2006) were reviewed for signalment, anatomic location, fracture classification and method of repair, technique and surgical duration, bacterial species isolated, postoperative care, onset of POI, and outcome. Of 192 horses (171 [89%] closed, 21 [11%] open fractures), 157 (82%) were discharged from the hospital. Infection occurred in 53 (28% horses), of which 31 (59%) were discharged. Repairs without POI were 7.25 times more likely to be discharged from the hospital. Closed fractures were 4.23 times more likely to remain uninfected and 4.59 times more likely to be discharged from the hospital compared with open fractures. Closed reduction and internal fixation was associated with a 2.5-fold reduction in rate of POI and a 5.9 times greater chance for discharge from the hospital compared with open reduction and internal fixation. Females had a strong trend for increased POI when compared with colts and stallion but not geldings. Overall rate of POI was 28%. Fracture classification, method of repair, gender, and surgical duration were significant risk factors.

  16. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    Science.gov (United States)

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  17. [Treatment of thoracolumbar burst fracture with lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh].

    Science.gov (United States)

    Zhang, Shi-min; Zhang, Zhao-jie; Liu, Yu-zhang; Zhang, Lu-tang; Li, Xing

    2011-11-01

    To discuss the efficacy of lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh in the treatment of severe thoracolumbar burst fracture. From January 2008 to January 2010, 21 patients with severe thoracolumbar burst fracture were treated with lateral anterior decompression, internal fixation with Ventrofix, bone graft with titanic mesh. There were 15 males and 6 females, ranging in age from 21 to 46 years with an average of 32.2 years. Segment of fracture: 3 cases were in T11, 6 cases in T12, 7 cases in L1, 5 cases in L2. The mean kyphosis angle was 20.1 degrees and loading of fracture was 7.8 scores. Twenty-one cases accompany with incomplete paralysis. Nerves functions were observed according to Frankel grade; correction and maintain of kyphosis angle were observed by X-rays and CT. All the patients were followed up from 12 to 34 months with an average of 18.5 years. Postoperative complication including injury of pleura in 1 case, dynamic ileus in 2 cases, ilioinguinal nerve injury in 1 case, faulty union of wound in 1 case. All the above complications got recovery after symptomatic treatment. The mean kyphosis angle in fusional segment were 4.2 degrees and the rate of correction was 79%. Nerves functions of all patients got improvement and no internal fixation fail, kyphosis angle obviously lost, titanium mesh shifting, loosening and breakage of screw were found at final follow-up. Lateral anterior decompression, bone graft with titanic mesh, internal fixation with Ventrofix is an idea technique for severe thoracolumber burst fracture, but the method can not be used for patient with severity osteoporosis.

  18. An in vivo evaluation of PLLA/PLLA-gHA nano-composite for internal fixation of mandibular bone fractures.

    Science.gov (United States)

    Peng, Weihai; Zheng, Wei; Shi, Kai; Wang, Wangshu; Shao, Ying; Zhang, Duo

    2015-11-09

    Internal fixation of bone fractures using biodegradable poly(L-lactic-acid) (PLLA)-based materials has attracted the attention of many researchers. In the present study, 36 male beagle dogs were randomly assigned to two groups: PLLA/PLLA-gHA (PLLA-grafted hydroxyapatite) group and PLLA group. PLLA/PLLA-gHA and PLLA plates were embedded in the muscular bags of the erector spinae and also implanted to fix mandibular bone fractures in respective groups. At 1, 2, 3, 6, 9, and 12 months postoperatively, the PLLA/PLLA-gHA and PLLA plates were evaluated by adsorption and degradation tests, and the mandibles were examined through radiographic analysis, biomechanical testing, and histological analysis. The PLLA/PLLA-gHA plates were non-transparent and showed a creamy white color, and the PLLA plates were transparent and faint yellow in color. At all time points following surgery, adsorption and degradation of the PLLA/PLLA-gHA plates were significantly less than those of the PLLA plates, and the lateral and longitudinal bending strengths of the surgically treated mandibles of the beagle dogs in the PLLA/PLLA-gHA group were significantly greater than those of the PLLA group and reached almost the value of intact mandibles at 12 months postoperatively. Additionally, relatively rapid bone healing was observed in the PLLA/PLLA-gHA group with the formation of new lamellar bone tissues at 12 months after the surgery. The PLLA/PLLA-gHA nano-composite can be employed as a biodegradable material for internal fixation of mandibular bone fractures.

  19. An in vivo evaluation of PLLA/PLLA-gHA nano-composite for internal fixation of mandibular bone fractures

    International Nuclear Information System (INIS)

    Peng, Weihai; Shi, Kai; Wang, Wangshu; Shao, Ying; Zhang, Duo; Zheng, Wei

    2015-01-01

    Internal fixation of bone fractures using biodegradable poly(L-lactic-acid) (PLLA)-based materials has attracted the attention of many researchers. In the present study, 36 male beagle dogs were randomly assigned to two groups: PLLA/PLLA-gHA (PLLA-grafted hydroxyapatite) group and PLLA group. PLLA/PLLA-gHA and PLLA plates were embedded in the muscular bags of the erector spinae and also implanted to fix mandibular bone fractures in respective groups. At 1, 2, 3, 6, 9, and 12 months postoperatively, the PLLA/PLLA-gHA and PLLA plates were evaluated by adsorption and degradation tests, and the mandibles were examined through radiographic analysis, biomechanical testing, and histological analysis. The PLLA/PLLA-gHA plates were non-transparent and showed a creamy white color, and the PLLA plates were transparent and faint yellow in color. At all time points following surgery, adsorption and degradation of the PLLA/PLLA-gHA plates were significantly less than those of the PLLA plates, and the lateral and longitudinal bending strengths of the surgically treated mandibles of the beagle dogs in the PLLA/PLLA-gHA group were significantly greater than those of the PLLA group and reached almost the value of intact mandibles at 12 months postoperatively. Additionally, relatively rapid bone healing was observed in the PLLA/PLLA-gHA group with the formation of new lamellar bone tissues at 12 months after the surgery. The PLLA/PLLA-gHA nano-composite can be employed as a biodegradable material for internal fixation of mandibular bone fractures. (paper)

  20. Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    LENUS (Irish Health Repository)

    Ong, J C Y

    2012-06-01

    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

  1. Treatment of Atypical Ulnar Fractures Associated with Long-Term Bisphosphonate Therapy for Osteoporosis: Autogenous Bone Graft with Internal Fixation

    Directory of Open Access Journals (Sweden)

    Yohei Shimada

    2017-01-01

    Full Text Available Long-term bisphosphonate use has been suggested to result in decreased bone remodelling and an increased risk of atypical fractures. Fractures of this nature commonly occur in the femur, and relatively few reports exist to show that they occur in other bones. Among eight previous reports of atypical ulnar fractures associated with bisphosphonate use, one report described nonunion in a patient who was treated with cast immobilization and another described ulna nonunion in one of three patients, all of whom were treated surgically with a locking plate. The remaining two surgical patients achieved bone union uneventfully following resection of the osteosclerotic lesion and iliac bone grafting before rigid fixation. We hypothesized that the discontinuation of bisphosphonate therapy, the use of teriparatide treatment, and low-intensity pulsed ultrasound (LIPUS might have been associated with fracture healing.

  2. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    Science.gov (United States)

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  3. Indications and outcome of Open Reduction and Internal Fixation of ...

    African Journals Online (AJOL)

    Background: Open reduction and internal fixation (ORIF) is a well-established surgical treatment of fractures worldwide. However, the indications and modes of stabilization of long bone fractures vary and are evolving .The general trend now is towards fixation with locked intramedullary nail (i.m nail) rather than plate and ...

  4. Eighth international congress on nitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  5. Therapeutic efficacy of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting for tuberculosis of lumbar vertebra

    Directory of Open Access Journals (Sweden)

    Jia-ming LIU

    2015-11-01

    Full Text Available Objective To evaluate the efficacy and safety of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting in the treatment of tuberculosis of mono-segmental lumbar vertebra. Methods From January 2010 to April 2013, 21 patients (9 males and 12 females with an average age of 49.1 years with mono-segmental tuberculosis of lumbar vertebra underwent surgery in our hospital were included. Eight patients had neurological deficit. The focus of tuberculosis was located on one side of the vertebral body, and all the patients had obvious signs of bone destruction on CT and MRI. All the patients were given anti-tuberculosis chemotherapy for 2-3 weeks before surgery. The local bone chips and autologous iliac cancellous bone were used as the intervertebral bone graft. Postoperative plain radiographs and CT were obtained to evaluate the fusion rate and degree of lumbar lordosis. The visual analogue scale score (VAS, erythrocyte sedimentation rate (ESR, and C-reactive protein (CRP before and after operation, and at final follow-up date were recorded. Results All the patients were followed up for 25.3±4.2 months. The mean operation time was 157±39 minutes, and the average blood loss was 470±143ml. The fusion rate of the interbody bone graft was 95.2%, with an average fusion period of 6.1±2.5 months. The neurological function was improved by 100%, and no severe complication or neurological injury occured. The preoperative and postoperative lordosis angles of the lumbar spine were 21.4°±5.7° and 33.6°±3.1°, respectively, and it was 31.3°±2.7° at the final follow up. The preoperative and postoperative VAS scores were 7.8±2.6 and 2.4±1.7 respectively, and it was 0.9±0.7 at the final follow up. The ESR and CRP were significantly decreased 3 months after surgery, and they became normal at 6 months. Conclusion Pedicle screw-rod internal fixation after one-stage posterior

  6. The application of closed reduction internal fixation and iliac bone block grafting in the treatment of acute displaced femoral neck fractures.

    Directory of Open Access Journals (Sweden)

    Zhiyong Li

    Full Text Available OBJECTIVE: This study aimed to evaluate the preliminary clinical and radiographic outcomes of acute displaced femoral neck fracture treated by closed reduction and internal fixation (CRIF with free iliac bone block grafting with comparison to a routine protocol of CRIF without bone grafting. METHODS: From December 2008 to February 2010, 220 adult patients with acute displaced femoral neck fractures were enrolled in this study. In study group, there were 124 patients (57 males, 67 females with a mean age of 44.8 years (range, 20-64 years. There were 70 transcervical fractures and 54 subcapital fractures. The patients were treated by CRIF and free iliac bone block grafting. The control group consisted of 96 adult patients (46 males, 50 females with a mean age of 46.3 years (range, 23-64 years. There were 61 transcervical fractures and 35 subcapital fractures. The patients in control group were treated by CRIF without bone grafting. RESULTS: In study group, 112 patients were followed up for an average of 27.4 months (range, 24-34 months. All fractures healed within 5 months. However, 10 patients presented AVN of the femoral heads. The mean Harris score was 88.6 (range, 41-100. In control group, 68 patients were followed up for an average of 31.2 months (range, 24-42 months. The rates of AVN of the femoral head and fracture nonunion in control group were 26.5% (18/68 and 16.2% (11/68, respectively, significantly higher than those in study group (both P<0.05. The mean Harris score in control group was 83.8 (41-100, significantly lower than that in study group (P<0.05. CONCLUSION: Acute displaced femoral neck fractures can be treated by CRIF and free iliac bone block grafting in a minimally invasive manner. This technique can guarantee uneventful fracture healing and significantly reduce the rate of femoral head osteonecrosis.

  7. Free flap reconstructions of tibial fractures complicated after internal fixation.

    Science.gov (United States)

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  8. Low bone mineral density is not related to failure in femoral neck fracture patients treated with internal fixation

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Overgaard, Søren

    2014-01-01

    the importance of low bone mineral density (BMD). Patients and methods - 140 consecutive patients (105 females, median age 80) treated with IF had a dual-energy X-ray absorptiometry (DXA) scan of the hip performed median 80 days after treatment. The patients' radiographs were evaluated for fracture displacement......, implant positioning, and quality of reduction. From a questionnaire completed during admission, 2 variables for comorbidity and walking disability were chosen. Primary outcome was low hip BMD (amount of mineral matter per square centimeter of hip bone) compared to hip failure (resection, arthroplasty...

  9. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  10. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    Science.gov (United States)

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P  .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P  0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  11. Design and Optimization of Resorbable Silk Internal Fixation Devices

    Science.gov (United States)

    Haas, Dylan S.

    Limitations of current material options for internal fracture fixation devices have resulted in a large gap between user needs and hardware function. Metal systems offer robust mechanical strength and ease of implantation but require secondary surgery for removal and/or result in long-term complications (infection, palpability, sensitivity, etc.). Current resorbable devices eliminate the need for second surgery and long-term complications but are still associated with negative host response as well as limited functionality and more difficult implantation. There is a definitive need for orthopedic hardware that is mechanically capable of immediate fracture stabilization and fracture fixation during healing, can safely biodegrade while allowing complete bone remodeling, can be resterilized for reuse, and is easily implantable (self-tapping). Previous work investigated the use of silk protein to produce resorbable orthopedic hardware for non- load bearing fracture fixation. In this study, silk orthopedic hardware was further investigated and optimized in order to better understand the ability of silk as a fracture fixation system and more closely meet the unfulfilled market needs. Solvent-based and aqueous-based silk processing formulations were cross-linked with methanol to induce beta sheet structure, dried, autoclaved and then machined to the desired device/geometry. Silk hardware was evaluated for dry, hydrated and fatigued (cyclic) mechanical properties, in vitro degradation, resterilization, functionalization with osteoinductive molecules and implantation technique for fracture fixation. Mechanical strength showed minor improvements from previous results, but remains comparable to current resorbable fixation systems with the advantages of self-tapping ability for ease of implantation, full degradation in 10 months, ability to be resterilized and reused, and ability to release molecules for osteoinudction. In vivo assessment confirmed biocompatibility, showed

  12. COMPUTER-AIDED OPTIMIZATION OF CHOICE AND POSITIONING OF BONE PLATES AND SCREWS USED FOR INTERNAL-FIXATION OF MANDIBULAR FRACTURES

    NARCIS (Netherlands)

    ROZEMA, FR; BOS, RRM; BOERING, G; VANWILLIGEN, JD

    1992-01-01

    The present study describes a biomechanical integrated model of the mandibular system in which the maxilla and mandible, the masticatory muscles, and the temporomandibular joints are regarded as one system. In this model, strains in plate-osteosynthesis devices for internal fixation of mandibular

  13. Comparison of Outcomes of Operatively Treated Bicondylar Tibial Plateau Fractures by External Fixation and Internal Fixation

    Directory of Open Access Journals (Sweden)

    CC Chan

    2012-03-01

    Full Text Available The outcome of bicondylar tibial plateau fractures treated with either external fixation (35 patients or internal fixation (24 patients was reviewed. Outcome measures included the Rasmussen score, clinical complications, development of osteoarthritis and the requirement for total knee replacement (TKR. Twenty-two (92% anatomical reductions were achieved in the internal fixation group compared to 27 (77% in the external fixation group. Infective complications were more common in the external fixation group (9 patients, 26% due to pin tract infection. There were no deep infections in the internal fixation group. The mean Rasmussen score was not significantly different (mean score 32 in external fixation and 29 in internal fixation between the two groups and the incidence of osteoarthritis was the same in both groups. Four patients in the external fixation group underwent a TKR compared to 5 patients in the internal fixation group. Bicondylar tibial plateau fractures have similar outcomes following external or internal fixation.

  14. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Can we improve fixation and outcomes? Use of bone substitutes.

    Science.gov (United States)

    Moroni, Antonio; Larsson, Sune; Hoang Kim, Amy; Gelsomini, Letizia; Giannoudis, Peter V

    2009-07-01

    Hip fractures secondary to osteoporosis are common in the elderly. Stabilizing these fractures until union is achieved is a challenge due to poor bone stock and insufficient purchase of the implant to the bone. The reported high rate of complications has prompted extensive research in the development of fixation techniques. Furthermore, manipulation of both the local fracture environment in terms of application of growth factors, scaffolds, and mesenchymal cells and the systemic administration of agents promoting bone formation and bone strength has been considered as a treatment option with promising results. There are only a few evidence-based studies reporting on fixation augmentation techniques. This article reports on the efficacy of bone graft substitutes for the fixation of hip fractures, in particular calcium phosphates, which have been used as granules, cements, and implant coatings.

  16. Eighth international congress on nitrogen fixation. Final program

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-31

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  17. Bone graft materials in fixation of orthopaedic implants in sheep

    DEFF Research Database (Denmark)

    Babiker, Hassan

    2013-01-01

    Bone graft is widely used within orthopaedic surgery especially in revision joint arthroplasty and spine fusion. The early implant fixation in the revision situation of loose joint prostheses is important for the long-term survival. Bone autograft has been considered as gold standard in many...... orthopaedic procedures, whereas allograft is the gold standard by replacement of extensive bone loss. However, the use of autograft is associated with donor site morbidity, especially chronic pain. In addition, the limited supply is a significant clinical challenge. Limitations in the use of allograft include...... the risk of bacterial contamination and disease transmission as well as non-union and poor bone quality. Other bone graft and substitutes have been considered as alternative in order to improve implant fixation. Hydroxyapatite and collagen type I composite (HA/Collagen) have the potential in mimicking...

  18. Bone compaction enhances implant fixation in a canine gap model

    DEFF Research Database (Denmark)

    Kold, Søren; Rahbek, Ole; Toft, Marianne

    2005-01-01

    A new bone preparation technique, compaction, has increased fixation of implants inserted with exact-fit or press-fit to bone. Furthermore, a demonstrated spring-back effect of compacted bone might be of potential value in reducing the initial gaps that often exist between clinical inserted...... implants and bone. However, it is unknown whether the compression and breakage of trabeculae during the compaction procedure results in impaired gap-healing of compacted bone. Therefore, we compared compaction with conventional drilling in a canine gap model. Grit-blasted titanium implants (diameter 6 mm...... that the beneficial effect of reduced gap size, as compacted bone springs back, is not eliminated by an impaired gap-healing of compacted bone....

  19. Resorbable screws for fixation of autologous bone grafts

    NARCIS (Netherlands)

    Raghoebar, GM; Liem, RSB; Bos, RRM; van der Wal, JE; Vissink, A

    The aim of this study was to evaluate the suitability of resorbable screws made of poly (D,L-lactide) acid (PDLLA) for fixation of autologous bone grafts related to graft regeneration and osseointegration of dental implants. In eight edentulous patients suffering from insufficient retention of their

  20. Mechanical design optimization of bioabsorbable fixation devices for bone fractures.

    Science.gov (United States)

    Lovald, Scott T; Khraishi, Tariq; Wagner, Jon; Baack, Bret

    2009-03-01

    Bioabsorbable bone plates can eliminate the necessity for a permanent implant when used to fixate fractures of the human mandible. They are currently not in widespread use because of the low strength of the materials and the requisite large volume of the resulting bone plate. The aim of the current study was to discover a minimally invasive bioabsorbable bone plate design that can provide the same mechanical stability as a standard titanium bone plate. A finite element model of a mandible with a fracture in the body region is subjected to bite loads that are common to patients postsurgery. The model is used first to determine benchmark stress and strain values for a titanium plate. These values are then set as the limits within which the bioabsorbable bone plate must comply. The model is then modified to consider a bone plate made of the polymer poly-L/DL-lactide 70/30. An optimization routine is run to determine the smallest volume of bioabsorbable bone plate that can perform and a titanium bone plate when fixating fractures of this considered type. Two design parameters are varied for the bone plate design during the optimization analysis. The analysis determined that a strut style poly-L-lactide-co-DL-lactide plate of 690 mm2 can provide as much mechanical stability as a similar titanium design structure of 172 mm2. The model has determined a bioabsorbable bone plate design that is as strong as a titanium plate when fixating fractures of the load-bearing mandible. This is an intriguing outcome, considering that the polymer material has only 6% of the stiffness of titanium.

  1. [Comparison of external fixation with or without limited internal fixation for open knee fractures].

    Science.gov (United States)

    Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S

    2018-03-01

    Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60

  2. [Treatment of femoral neck fracture--preference to internal fixation].

    Science.gov (United States)

    Minato, Izumi

    2011-03-01

    In the guidelines for the treatment of femoral neck fracture, prosthetic replacement is recommended in displaced one and internal fixation is in undisplaced one. However, in the long view, survived femoral head after internal fixation can be superior to prosthesis which will deteriorate as time goes by. Surgical method should be considered not only by type of fracture but general status of the patient.

  3. Internal Versus External Fixation of Charcot Midfoot Deformity Realignment.

    Science.gov (United States)

    Lee, Daniel J; Schaffer, Joseph; Chen, Tien; Oh, Irvin

    2016-07-01

    Internal and external fixation techniques have been described for realignment and arthrodesis of Charcot midfoot deformity. There currently is no consensus on the optimal method of surgical reconstruction. This systematic review compared the clinical results of surgical realignment with internal and external fixation, specifically in regard to return to functional ambulation, ulcer occurrence, nonunion, extremity amputation, unplanned further surgery, deep infection, wound healing problems, peri- or intraoperative fractures, and total cases with any complication. A search of multiple databases for all relevant articles published from January 1, 1990, to March 22, 2014, was performed. A logistic regression model evaluated each of the outcomes and its association with the type of fixation method. The odds of returning to functional ambulation were 25% higher for internal fixation (odds ratio [OR], 1.259). Internal fixation had a 42% reduced rate of ulcer occurrence (OR, 0.578). External fixation was 8 times more likely to develop radiographic nonunion than internal fixation (OR, 8.2). Internal fixation resulted in a 1.5-fold increase in extremity amputation (OR, 1.488), a 2-fold increase in deep infection (OR, 2.068), a 3.4-fold increase in wound healing complications (OR, 3.405), and a 1.5-fold increase in the total number of cases experiencing any complication (OR, 1.525). This was associated with a 20% increase in the need for unplanned further surgery with internal fixation (OR, 1.221). Although internal fixation may decrease the risk of nonunion and increase return to functional ambulation, it had a higher rate of overall complications than external fixation for realignment and arthrodesis of Charcot midfoot deformity. [Orthopedics. 2016; 39(4):e595-e601.]. Copyright 2016, SLACK Incorporated.

  4. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    Science.gov (United States)

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  5. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation

    OpenAIRE

    Gunst, S; Del Chicca, Francesca; Fürst, Anton; Kuemmerle, Jan M

    2016-01-01

    REASONS FOR PERFORMING STUDY: There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. OBJECTIVES: To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. STUDY DESIGN: Retrospective case series. METHODS: All horses diagnosed with a central tarsa...

  6. Bone compaction enhances fixation of weightbearing titanium implants

    DEFF Research Database (Denmark)

    Kold, Søren; Rahbek, Ole; Vestermark, Marianne

    2005-01-01

    are weightbearing, the effects of compaction on weightbearing implants were examined. The hypothesis was that compaction would increase implant fixation compared with conventional drilling. Porous-coated titanium implants were inserted bilaterally into the weightbearing portion of the femoral condyles of dogs....... In each dog, one knee had the implant cavity prepared with drilling, and the other knee was prepared with compaction. Eight dogs were euthanized after 2 weeks, and eight dogs were euthanized after 4 weeks. Femoral condyles from an additional eight dogs represented Time 0. Compacted specimens had higher...... bone-implant contact and periimplant bone density at 0 and 2 weeks, but not at 4 weeks. A biphasic response of compaction was found with a pushout test, as compaction increased ultimate shear strength and energy absorption at 0 and 4 weeks, but not at 2 weeks. This biphasic response indicates...

  7. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  8. History of internal fixation (part 1): early developments with wires and plates before World War II.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-06-01

    Though the date at which an orthopaedic implant was first used cannot be ascertained with any certainty, the fixation of bone fracture using an iron wire was reported for the first time in a French manuscript in 1775. The first techniques of operative fracture treatment were developed at the end of the 18th and in the beginning of the 19th centuries. The use of cerclage wires to fix fractures was the most frequent fixation at this time. The French Berenger-Feraud (1832-1900) had written the first book on internal fixation. However internal fixation of fractures could not become a practical method before Lister had ensured the safety of open reduction and internal fixation in the treatment of fractures. Lister is not only the father of asepsis; he also used metal wires to fix even closed fractures. The first internal fixation by means of a plate and screws was described by Carl Hansmann in 1858 in Hamburg. Nevertheless, Arbuthnot Lane (1892) and Albin Lambotte (1905) are considered to be the founders of this method, which was further developed by Sherman in the first part of the 20th century.

  9. REVERSE ENGINEERING OF THE MITKOVIC TYPE INTERNAL FIXATOR FOR LATERAL TIBIAL PLATEAU

    Directory of Open Access Journals (Sweden)

    Nikola Vitković

    2015-12-01

    Full Text Available In orthopaedic surgery it is very important to use proper fixation techniques in the treatment of various medical conditions, i.e. bone fractures or other traumas. If an internal fixation method, such as plating, is required, it is possible to use Dynamic Compression Plates (DCP or Locking Compression Plates (LCP and their variants. For DCP implants it is important to match the patient's bone shape with the most possible accuracy, so that the most frequent implant bending is applied in the surgery. For LCP implants it is not so important to match the patient’s bone shape, but additional locking screw holes are required. To improve the geometrical accuracy and anatomical correctness of the shape of DCP and to improve the LCP geometric definition, new geometrical modelling methods for the Mitkovic type internal fixator for Lateral Tibia Plateau are developed and presented in this research. The presented results are quite promising; it can be concluded that these methods can be applied to the creation of geometrical models of internal fixator customized for the given patient or optimized for a group of patients with required geometrical accuracy and morphological correctness.

  10. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    Science.gov (United States)

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  11. Assessment of activated porous granules on implant fixation and early bone formation in sheep

    Directory of Open Access Journals (Sweden)

    Ming Ding

    2016-04-01

    Conclusion: In conclusion, despite nice bone formation and implant fixation in all groups, bioreactor activated graft material did not convincingly induce early implant fixation similar to allograft, and neither bioreactor nor by adding BMA credited additional benefit for bone formation in this model.

  12. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Science.gov (United States)

    2010-04-01

    ... appliances and accessories. 888.3030 Section 888.3030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  13. Outcome of rail fixator system in reconstructing bone gap

    Directory of Open Access Journals (Sweden)

    Amit Lakhani

    2014-01-01

    Conclusion: All patients well tolerated rail fixator with good functional results and gap reconstruction. Easy application of rail fixator and comfortable distraction procedure suggest rail fixator a good alternative for gap reconstruction of limbs.

  14. Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection

    Science.gov (United States)

    Gulati, Karan; Aw, Moom Sinn; Losic, Dusan

    2011-10-01

    Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [TNT] arrays formed with a drug delivery capability to design alternative bone fixation tools for orthopaedic applications. A titania layer with an array of nanotube structures was synthesised on the surface of a Ti wire by electrochemical anodisation and loaded with antibiotic (gentamicin) used as a model of bone anti-bacterial drug. Successful fabrication of TNT structures with pore diameters of approximately 170 nm and length of 70 μm is demonstrated for the first time in the form of wires. The drug release characteristics of TNT-Ti wires were evaluated, showing a two-phase release, with a burst release (37%) and a slow release with zero-order kinetics over 11 days. These results confirmed our system's ability to be applied as a drug-eluting tool for orthopaedic applications. The established biocompatibility of TNT structures, closer modulus of elasticity to natural bones and possible inclusion of desired drugs, proteins or growth factors make this system a promising alternative to replace conventional bone implants to prevent bone infection and to be used for targeted treatment of bone cancer, osteomyelitis and other orthopaedic diseases.

  15. The effects of bone marrow aspirate, bone graft, and collagen composites on fixation of titanium implants

    DEFF Research Database (Denmark)

    Babiker, Hassan; Ding, Ming; Sandri, Monica

    2012-01-01

    Replacement of extensive local bone loss especially in revision joint arthroplasty and spine fusion is a significant clinical challenge. Allograft and autograft have been considered as gold standards for bone replacement. However, there are several disadvantages such as donor site pain, bacterial...... contamination, and non union as well as the potential risk of disease transmission. Hydroxyapatite and collagen composites (HA/Collagen) have the potential in mimicking and replacing skeletal bones. This study attempted to determine the effects of newly developed HA/Collagen-composites with and without bone...... marrow aspirate (BMA) on enhancement of bone implant fixation. Method: Titanium alloy implants were inserted into bilateral femoral condyles of eight skeletally mature sheep, four implants per sheep. The implant had a circumferential gap of 2 mm. The gap was filled with: HA/Collagen; HA...

  16. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    Science.gov (United States)

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  17. The effect of bone marrow aspirate, bone graft and collagen composites on fixation of bone implants

    DEFF Research Database (Denmark)

    Babiker, Hassan; Ding, Ming; Overgaard, Søren

    2007-01-01

     Introduction: Replacement of extensive local bone loss especially in revision joint arthroplasties is a significant clinical challenge. Autogenous and allogenic cancellous bone grafts have been the gold standard in reconstructive orthopaedic surgery, but it is well known that there is morbidity...... associated with harvesting of autogenous bone graft and limitations in the quantity of bone available. Disadvantages of allograft include the risk of bacterial or viral contamination and non union as well as the potential risk of disease transmission. Alternative options are attractive and continue...... to be sought. Hydroxyapatite and collagen composites have the potential in mimicking and replacing skeletal bones. Aim: This study attempted to determine the effect of hydroxyapatite/collagen composites in the fixation of bone implants. The composites used in this study is produced by Institute of Science...

  18. Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.

    Science.gov (United States)

    Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F

    2016-09-01

    A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.

  19. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  20. Humeral repair in birds by guided tissue regeneration and external and internal associated fixation techniques

    International Nuclear Information System (INIS)

    Delogu, M.

    1993-01-01

    Ten pigeons (Columba livia domestic form) with humeral diaphyseal fracture were treated with external and internal fixation techniques (Boston technique and intamedullary pin). Longitudinal space was intentionally left between fracture surfaces during osteosynthesis. This space was filled with bovine lyophilized collagen, set around an intramedullary pin, in five samples. Ossification process was checked by radiography every seven days. Results show the utility of this technique in pneumatic bird bones. In fact, shortening control and callus formation facility were observed [it

  1. Treatment of Spinal Tuberculosis by Debridement, Interbody Fusion and Internal Fixation via Posterior Approach Only.

    Science.gov (United States)

    Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang

    2016-02-01

    Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting

  2. Fixation strength analysis of cup to bone material using finite element simulation

    NARCIS (Netherlands)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; Van Der Heide, Emile

    2016-01-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw

  3. Pediatric mandibular fractures treated by rigid internal fixation.

    Science.gov (United States)

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  4. Stress analysis of implant-bone fixation at different fracture angle

    Science.gov (United States)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  5. Functional Outcome of Internal Fixation of Radial and Ulna Fracture

    Directory of Open Access Journals (Sweden)

    mehrdad Mansouri

    2006-02-01

    Conclusion: Anatomic reduction and internal fixation is the standard method for treatment of fractures by displacing radios and ulna in adults. According to results, it seems more intension to motions specially pronation and muscle strengthening foream after surgery will have affect on improving patients’ function specially pronation and Grip strength.

  6. External Fixation versus two-stage Open Reduction Internal Fixation of distal intra-articular Tibia fractures; a Systematic Review

    DEFF Research Database (Denmark)

    Ladeby Erichsen, Julie; Jensen, Carsten; Damborg, Frank Lindhøj

    Internal Fixation (ORIF) or External Fixation (EF). Method : A search was conducted using PUBMED, Embase, Cochrane Central, Open Grey, Orthopaedic Proceedings and WHO International Clinical Trials Registry Platform. Studies with level of evidence I-IV comparing EF with two-stage ORIF of DIATF in patients...

  7. Experimental Fracture Model versus Osteotomy Model in Metacarpal Bone Plate Fixation

    Directory of Open Access Journals (Sweden)

    S. Ochman

    2011-01-01

    Full Text Available Introduction. Osteotomy or fracture models can be used to evaluate mechanical properties of fixation techniques of the hand skeleton in vitro. Although many studies make use of osteotomy models, fracture models simulate the clinical situation more realistically. This study investigates monocortical and bicortical plate fixation on metacarpal bones considering both aforementioned models to decide which method is best suited to test fixation techniques. Methods. Porcine metacarpal bones (=40 were randomized into 4 groups. In groups I and II bones were fractured with a modified 3-point bending test. The intact bones represented a further control group to which the other groups after fixation were compared. In groups III and IV a standard osteotomy was carried out. Bones were fixated with plates monocortically (group I, III and bicortically (group II, IV and tested for failure. Results. Bones fractured at a mean maximum load of 482.8 N ± 104.8 N with a relative standard deviation (RSD of 21.7%, mean stiffness was 122.3 ± 35 N/mm. In the fracture model, there was a significant difference (=0.01 for maximum load of monocortically and bicortically fixed bones in contrast to the osteotomy model (=0.9. Discussion. In the fracture model, because one can use the same bone for both measurements in the intact state and the bone-plate construct states, the impact of inter-individual differences is reduced. In contrast to the osteotomy model there are differences between monocortical and bicortical fixations in the fracture model. Thus simulation of the in vivo situation is better and seems to be suitable for the evaluation of mechanical properties of fixation techniques on metacarpals.

  8. Management and follow up of tibial plateau fractures by ′T′ clamp external fixator and limited internal fixation

    Directory of Open Access Journals (Sweden)

    Thimmegowda M

    2005-01-01

    Full Text Available Background: Tibial plateau fractures are difficult to treat especially when soft tissue is compromised by open reduction and internal fixation. Many methods have be1en tried in the past to manage these cases of which external fixation were shown to be effective as they limit the soft tissue and wound complications. Methods: Complex tibial plateau fractures of sixteen patients were treated by closed reduction, fixation of articular fragments by screws and application of unilateral external fixator. The external fixator was kept in place till fracture united clinically and radiologically. The patients were followed up for at least one year to assess the function of the knee joint Results: The average duration of external fixation was 13 weeks. All the fractures healed. Pin track infection (five patients and instability (six patients of the knee were encountered with this procedure. The average duration of follow up was 62 weeks. The mean range of motion was 1250 arc. The IOWA knee score averaged 90.3 points. Conclusions: External fixation with limited internal fixation may be effective in the management of complex tibial plateau fractures which requires further support from studies with large sample size. ′T′ clamp external fixation with limited Internal fixation is the procedure of choice when alignment, stability, early mobilisation is required in a soft tissue compromised tibial plateau fractures.

  9. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    Science.gov (United States)

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  10. Demineralized bone matrix and human cancellous bone enhance fixation of titanium implants

    DEFF Research Database (Denmark)

    Babiker, Hassan; Ding, Ming; Overgaard, Søren

    Best Poster 5Demineralized bone matrix and human cancellous bone enhance fixation of titanium implants AuthorsBabiker , H.; Ding M.; Overgaard S.InstitutionOrthopaedic Research Laboratory, Department of Orthopaedic Surgery, Odense University Hospital, Clinical Institute, University of Southern...... from human tissue were included (IsoTis OrthoBiologics, Inc. USA). Both materials are commercially available. Titanium alloy implants (Biomet Inc.) of 10 mm in length and 10 mm in diameter were inserted bilaterally into the femoral condyles of 8 skeletally mature sheep. Thus four implants...... with a concentric gap of 2 mm were implanted in each sheep. The gap was filled with: DBM; DBM/CB with ratio of 1/3; DBM/allograft with ratio of 1/3; or allograft (Gold standard), respectively. Standardised surgical procedure was used1. At sacrifice, 6 weeks after surgery, both distal femurs were harvested...

  11. Internal fixation of mandibular angle fractures: a meta-analysis.

    Science.gov (United States)

    Regev, Eran; Shiff, Jacob S; Kiss, Alex; Fialkov, Jeffrey A

    2010-06-01

    The degree of rigidity of internal fixation required for the treatment of mandibular angle fractures has long been at the center of debate in the literature. A statistical comparison between rigid fixation and monocortical fixation has been difficult because of multiple terms, definitions, and technical variations. The purpose of this study was to use the meta-analysis tool to combine information from multiple studies and to compare complication rates for different fixation methods. An English language literature search was conducted for articles on mandibular angle fractures. Information was collected on four variables of interest: compression/noncompression technique, monocortical/bicortical screws, number of plates, and location of plates. Five outcome rates were analyzed: infection, reoperation, hardware removal, malunion, and nonunion. Meta-analyses were run using Comprehensive Meta Analysis, version 2.2.03. Twenty-four studies with relevant data on the variables and outcomes of interest met the inclusion criteria. Significantly higher rates of infection, reoperation, and hardware removal were found for compression compared with noncompression, two plates compared with one plate, and for plates located on both the inferior and superior borders as compared with superior or inferior only. There were also significantly higher infection rates for bicortical screws compared with monocortical screws and higher malunion rates for compression compared with noncompression plating techniques. The results of this meta-analysis found lower complication rates with the use of noncompression, monocortical, and single-plate fixation, supporting the trend toward a single, superiorly placed, monocortical miniplate for fixation of mandibular angle fractures.

  12. Arthroscopic Meniscal Allograft Transplantation With Soft-Tissue Fixation Through Bone Tunnels.

    Science.gov (United States)

    Spalding, Tim; Parkinson, Ben; Smith, Nick A; Verdonk, Peter

    2015-10-01

    Meniscal allograft transplantation improves clinical outcomes for patients with symptomatic meniscus-deficient knees. We describe an established arthroscopic technique for meniscal allograft transplantation without the need for bone fixation of the meniscal horns. After preparation of the meniscal bed, the meniscus is parachuted into the knee through a silicone cannula and the meniscal horns are fixed with sutures through bone tunnels. The body of the meniscus is then fixed with a combination of all-inside and inside-out sutures. This technique is reliable and reproducible and has clinical outcomes comparable with those of bone plug fixation techniques.

  13. [Effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults].

    Science.gov (United States)

    Pu, Xiaobing; Yang, Shuangshi; Cao, Haiquan; Jing, Xingquan; Yin, Jun

    2014-03-01

    To investigate the effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults. Between January 2008 and December 2011, 32 patients with lumbar spondylolysis underwent U-shape titanium screw-rod fixation system with bone autografting. All patients were male with an average age of 22 years (range, 19-32 years). The disease duration ranged from 3 to 24 months (mean, 14 months). L3 was involved in spondylolysis in 2 cases, L4 in 10 cases, and L5 in 20 cases. The preoperative visual analogue scale (VAS) and Oswestry disability index (ODI) scores were 8.0 +/- 1.1 and 75.3 +/- 11.2, respectively. The operation time was 80-120 minutes (mean, 85 minutes), and the blood loss was 150-250 mL (mean, 210 mL). Primary healing of incision was obtained in all patients without complications of infection and nerve symptom. Thirty-two patients were followed up 12-24 months (mean, 14 months). Low back pain was significantly alleviated after operation. The VAS and ODI scores at 3 months after operation were 1.0 +/- 0.5 and 17.6 +/- 3.4, respectively, showing significant differences when compared with preoperative ones (t = 30.523, P = 0.000; t = 45.312, P = 0.000). X-ray films and CT showed bone fusion in the area of isthmus defects, with the bone fusion time of 6-12 months (mean, 9 months). During follow-up, no secondary lumbar spondyloly, adjacent segment degeneration, or loosening or breaking of internal fixator was found. The U-shape titanium screw-rod fixation system with bone autografting is a reliable treatment for lumbar spondylolysis of young adults because of a high fusion rate, minimal invasive, and maximum retention of lumbar range of motion.

  14. Radiographic healing and remodelling of cortical and cancellous bone grafts after rigid plate fixation

    International Nuclear Information System (INIS)

    Waris, P.; Karaharju, E.; Slaetis, P.; Paavolainen, P.

    1980-01-01

    Cortical and cancellous interposition grafts, with rigid plate fixation, in the tibiofibular bones of 130 rabbits were followed radiographically for one year. The cancellous grafts healed earlier, but by 12 weeks both graft types had been incorporated, the distal host-graft interface being the last to heal. Progressive cancellous transformation in both the graft and host bone led to an increased over-all bone diameter, a widened medullary canal and a thinned porotic wall. (Auth.)

  15. Treatment Approach for Infection of Healed Fractures After Internal Fixation.

    Science.gov (United States)

    Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A

    2017-11-01

    To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. Design and fabrication of biomimetic multiphased scaffolds for ligament-to-bone fixation.

    Science.gov (United States)

    He, Jiankang; Zhang, Wenyou; Liu, Yaxiong; Li, Xiang; Li, Dichen; Jin, Zhongmin

    2015-05-01

    Conventional ligament grafts with single material composition cannot effectively integrate with the host bones due to mismatched properties and eventually affect their long-term function in vivo. Here we presented a multi-material strategy to design and fabricate composite scaffolds including ligament, interface and bone multiphased regions. The interface region consists of triphasic layers with varying material composition and porous structure to mimic native ligament-to-bone interface while the bone region contains polycaprolactone (PCL) anchor and microchanneled ceramic scaffolds to potentially provide combined mechanical and biological implant-bone fixation. Finite element analysis (FEA) demonstrated that the multiphased scaffolds with interference value smaller than 0.5 mm could avoid the fracture of ceramic scaffold during the implantation process, which was validated by in-vitro implanting the multiphased scaffolds into porcine joint bones. Pull-out experiment showed that the initial fixation between the multiphased scaffolds with 0.47 mm interference and the host bones could withstand the maximum force of 360.31±97.51 N, which can be improved by reinforcing the ceramic scaffolds with biopolymers. It is envisioned that the multiphased scaffold could potentially induce the regeneration of a new bone as well as interfacial tissue with the gradual degradation of the scaffold and subsequently realize long-term biological fixation of the implant with the host bone. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. The initial safe range of motion of the ankle joint after three methods of internal fixation of simulated fractures of the medial malleolus.

    Science.gov (United States)

    Shimamura, Yoshio; Kaneko, Kazuo; Kume, Kazuhiko; Maeda, Mutsuhiro; Iwase, Hideaki

    2006-07-01

    Previous studies have demonstrated the safe passive range of ankle motion for inter-bone stiffness after internal fixation under load but there is a lack of information about the safe range of ankle motion for early rehabilitation in the absence of loading. The present study was designed to assess the effect of ankle movement on inter-bone displacement characteristics of medial malleolus fractures following three types of internal fixation to determine the safe range of motion. Five lower legs obtained during autopsy were used to assess three types of internal fixation (two with Kirschner-wires alone; two with Kirschner-wires plus tension band wiring; and, one with an AO/ASIF malleolar screw alone). Following a simulated fracture by sawing through the medial malleolus the displacement between the fractured bone ends was measured during a passive range of movement with continuous monitoring using omega (Omega) shaped transducers and a biaxial flexible goniometer. Statistical analysis was performed with repeated measures analysis of variance. Inter-bone displacement was not proportional to the magnitude of movement throughout the range of ankle motion as, when separation exceeded 25 microm, there was increasingly wide separation as plantar-flexion or dorsal-flexion was increased. There was no statistical significant difference between the small amount of inter-bone displacement observed with three types of fixation within the safe range of dorsal-flexion and plantar-flexion for early rehabilitation. However the inter-bone separation when fixation utilized two Kirschner-wires alone tended to be greater than when using the other two types of fixation during dorsal-flexion and eversion. The present study revealed a reproducible range of ankle motion for early rehabilitation which was estimated to be within the range of 20 degrees of dorsal-flexion and 10 degrees of plantar-flexion without eversion. Also, internal fixation with two Kirschner-wires alone does not seem to

  18. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    OpenAIRE

    Samir Joshi; Rajesh Kshirsagar; Akshay Mishra; Rahul Shah

    2015-01-01

    Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plate...

  19. Posterior treatment of delayed traumatic atlantoaxial joint dislocation with apofix internal fixation

    International Nuclear Information System (INIS)

    Qing Wei; Jiang Weimin; Shi Jinhui; Li Xuefeng; Yang Huilin; Tang Tiansi

    2010-01-01

    Objective: To assess the effect of posterior fixation and fusion with Apofix device for the treatment of delayed traumatic atlantoaxial joint dislocation. Methods: Eighteen patients with delayed traumatic atlantoaxial joint dislocation were included. Posterior fixation and fusion with Apofix device were performed. First step was one or two week skull traction. After the atlantoaxial joint dislocation had been reduced, the posterior fixation and fusion with Apofix was performed. Using local anaesthesia, atlantoaxial interval and posterior structure of atlas and dentata were exposed by midline operative approach. Apofix interlaminar clamps were placed at posterior arch of atlas and odontoid vertebral laminae, autologous iliac bone graft was placed for fusion. Then the device to proper position was pressurized and items locked. Results: All of the patients were followed up, the mean follow-up period was 38 months (13 ∼ 84 months). Fifteen patients obtained complete reduction, the others were partial reduction. Seventeen patients had successful fusion after 3 or 4 months, only 1 patient who had partial reduction had internal fixation loose and nonfusion, leading to recurrence of atlantoaxial joint dislocation. An occipitocervical fusion surgery was performed on this patient. As to neurological assessment, 16 patients had neurological deficit before operation, while 6 of them recovered completely after operation, another 10 patients' neurological status improved significantly. JOA score was improved from 9.5 pre-operative to 15.8 post-operative. Conclusion: Apofix internal fixation and fusion seems to be feasible in treatment of delayed traumatic atlantoaxial joint dislocation. Successful reduction before operation and proper treatment after operation is also important. (authors)

  20. Enhancement of Apoptosis by Titanium Alloy Internal Fixations during Microwave Treatments for Fractures: An Animal Study.

    Directory of Open Access Journals (Sweden)

    Gang Wang

    Full Text Available Microwaves are used in one method of physical therapy and can increase muscle tissue temperature which is useful for improving muscle, tendon and bone injuries. In the study, we sought to determine whether titanium alloy internal fixations influence apoptosis in tissues subjected to microwave treatments at 2,450 MHz and 40 W during the healing of fractures because this issue is not yet fully understood.In this study, titanium alloy internal fixations were used to treat 3.0-mm transverse osteotomies in the middle of New Zealand rabbits' femurs. After the operation, 30-day microwave treatments were applied to the 3.0 mm transverse osteotomies 3 days after the operation. The changes in the temperatures of the muscle tissues in front of the implants or the 3.0 mm transverse osteotomies were measured during the microwave treatments. To characterize the effects of titanium alloy internal fixations on apoptosis in the muscles after microwave treatment, we performed TUNEL assays, fluorescent real-time (quantitative PCR, western blotting analyses, reactive oxygen species (ROS detection and transmission electron microscopy examinations.The temperatures were markedly increased in the animals with the titanium alloy implants. Apoptosis in the muscle cells of the implanted group was significantly more extensive than that in the non-implanted control group at different time points. Transmission electron microscopy examinations of the skeletal muscles of the implanted groups revealed muscular mitochondrial swelling, vacuolization. ROS, Bax and Hsp70 were up-regulated, and Bcl-2 was down-regulated in the implanted group.Our results suggest that titanium alloy internal fixations caused greater muscular tissue cell apoptosis following 2,450 MHz, 40 W microwave treatments in this rabbit femur fracture models.

  1. Operative treatment of early infection after internal fixation of limb fractures (exclusive of severe open fractures).

    Science.gov (United States)

    Bonnevialle, P

    2017-02-01

    Early infection after open reduction and internal fixation (ORIF) of a limb bone is defined as bacteriologically documented, deep and/or superficial surgical-site infection (SSI) diagnosed within 6months after the surgical procedure. This interval is arbitrarily considered sufficient to obtain fracture healing. The treatment of early infection after ORIF should be decided by a multidisciplinary team. The principles are the same as for revision arthroplasty. Superficial SSIs should be differentiated from deep SSIs, based on the results of bacteriological specimens collected using flawless technique. A turning point in the local microbial ecology occurs around the third or fourth week, when a biofilm develops around metallic implants. This biofilm protects the bacteria. The treatment relies on both non-operative and operative measures, which are selected based on the time to occurrence of the infection, condition of the soft tissues, and stage of bone healing. Both the surgical strategy and the antibiotic regimen should be determined during a multidisciplinary discussion. When treating superficial SSIs after ORIF, soft-tissue management is the main challenge. The treatment differs according to whether the hardware is covered or exposed. Defects in the skin and/or fascia can be managed using reliable reconstructive surgery techniques, either immediately or after a brief period of vacuum-assisted closure. In deep SSIs, deciding whether to leave or to remove the hardware is difficult. If the hardware is removed, the fracture site can be stabilised provisionally using either external fixation or a cement rod. Once infection control is achieved, several measures can be taken to stimulate bone healing before the end of the classical 6-month interval. If the hardware was removed, then internal fixation must be performed once the infection is eradicated. Copyright © 2016. Published by Elsevier Masson SAS.

  2. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    Directory of Open Access Journals (Sweden)

    Masanori Fujii

    2017-01-01

    Full Text Available Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months. The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE angle and the bone coverage index (BCI from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3% and the minimum cup-CE angle was −9.2° (BCI: 48.8%. Thin radiolucent lines were observed in 5 hips (2.3%, which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50% was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%.

  3. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  4. Virtual haptic system for intuitive planning of bone fixation plate placement

    Directory of Open Access Journals (Sweden)

    Kup-Sze Choi

    2017-01-01

    Full Text Available Placement of pre-contoured fixation plate is a common treatment for bone fracture. Fitting of fixation plates on fractured bone can be preoperatively planned and evaluated in 3D virtual environment using virtual reality technology. However, conventional systems usually employ 2D mouse and virtual trackball as the user interface, which makes the process inconvenient and inefficient. In the paper, a preoperative planning system equipped with 3D haptic user interface is proposed to allow users to manipulate the virtual fixation plate intuitively to determine the optimal position for placement on distal medial tibia. The system provides interactive feedback forces and visual guidance based on the geometric requirements. Creation of 3D models from medical imaging data, collision detection, dynamics simulation and haptic rendering are discussed. The system was evaluated by 22 subjects. Results show that the time to achieve optimal placement using the proposed system was shorter than that by using 2D mouse and virtual trackball, and the satisfaction rating was also higher. The system shows potential to facilitate the process of fitting fixation plates on fractured bones as well as interactive fixation plate design.

  5. End-stage hindfoot arthrosis: outcomes of tibiocalcaneal fusion using internal and Ilizarov fixation.

    Science.gov (United States)

    Crawford, Brooke; Watson, J Tracy; Jackman, James; Fissel, Brian; Karges, David E

    2014-01-01

    End-stage post-traumatic pantalar arthrosis from ankle, pilon, and talus fractures has often been complicated by infection, bone loss, and a soft tissue deficit. Patients can present with neuropathy, diabetes, tobacco use, and previously failed arthrodesis. Fusion in this population has been challenging, with nonunion rates up to 30%, often leading to amputation. We reviewed the results of a standardized protocol that combined simultaneous internal fixation with the Ilizarov technique to achieve fusion in high-risk patients. With institutional review board approval, a retrospective review of the patients treated with simultaneous internal fixation and an Ilizarov frame was undertaken. The records and radiographs allowed identification of the comorbidities and the presence or absence of successful fusion. Complications were acknowledged and treated. Fifteen patients had undergone the procedure. The mean follow-up period was 27.9 (range 9 to 67) months. Thirteen patients (86.67%) had had previous fusion failure. Twelve patients (80%) had developed post-traumatic arthrosis, 5 (33.33%) of whom had open injuries. All patients had 1 comorbidity, and 10 (66.67%) had multiple, including rheumatoid arthritis, diabetes (types 1 and 2), and smoking. Four patients (26.67%) presented with deep infection and bone loss. Union was achieved in 11 (73.33%), with 12 (80%) patients experiencing profound pain relief. Seven patients (46.67%) required symptomatic hardware removal. Three patients (20%) eventually underwent below-the-knee amputation for recalcitrant nonunion. Statistically significant correlations were found between smoking and wound infection and revision and between nonunion and amputation. Our results have indicated that combined internal fixation with Ilizarov application can provide a strong surgical option for the management of end-stage, pantalar arthritis. More studies are needed to compare the cohort outcomes and gait analysis in these patients with those who have

  6. Design, fabrication and structural optimization of tubular carbon/Kevlar®/PMMA/graphene nanoplate composite for bone fixation prosthesis.

    Science.gov (United States)

    Nasiri, F; Ajeli, S; Semnani, D; Jahanshahi, M; Emadi, R

    2018-05-02

    The present work investigates the mechanical properties of tubular carbon/Kevlar ® composite coated with poly(methyl methacrylate)/graphene nanoplates as used in the internal fixation of bones. Carbon fibers are good candidates for developing high-strength biomaterials and due to better stress transfer and electrical properties, they can enhance tissue formation. In order to improve carbon brittleness, ductile Kevlar ® was added to the composite. The tubular carbon/Kevlar ® composites have been prepared with tailorable braiding technology by changing the fiber pattern and angle in the composite structure and the number of composite layers. Fuzzy analyses are used for optimizing the tailorable parameters of 80 prepared samples and then mechanical properties of selected samples are discussed from the viewpoint of mechanical properties required for a bone fixation device. Experimental results showed that with optimizing braiding parameters the desired composite structure with mechanical properties close to bone properties could be produced. Results showed that carbon/Kevlar ® braid's physical properties, fiber composite distribution and diameter uniformity resulted in matrix uniformity, which enhanced strength and modulus due to better ability for distributing stress on the composite. Finally, as graphene nanoplates demonstrated their potential properties to improve wound healing intended for bone replacement, so reinforcing the PMMA matrix with graphene nanoplates enhanced the composite quality, for use as an implant.

  7. The effect of Hydroxyapatite/collagen I composites, bone marrow aspirate and bone graft on fixation of bone implants in sheep

    DEFF Research Database (Denmark)

    Babiker, Hassan

      The effect of Hydroxyapatite/collagen I composites, bone marrow aspirate and bone graft on fixation of bone implants IN SHEEP   Ph.D. Student, Hassan Babiker; Associate Professor, Ph.D. Ming Ding; Professor, dr.med., Soren Overgaard. Department of Orthopaedic Surgery, Odense University Hospital......, Odense, Denmark   Background: Hydroxyapatite and collagen composites (HA/coll) have the potential in mimicking and replacing skeletal bones. This study attempted to determine the effect of newly developed HA/coll-composites with and without bone marrow aspirate (BMA) in order to enhance the fixation...... of bone implants.   Materials and Methods: Titanium alloy implants were inserted into bilateral femoral condyles of 8 skeletally mature sheep, four in each sheep. The implant has a circumferential gap of 2 mm. The gap was filled with: HA/coll; HA/coll-BMA; autograft or allograft. Allograft was served...

  8. Evaluation of functional outcome of pilon fractures managed with limited internal fixation and external fixation: A prospective clinical study.

    Science.gov (United States)

    Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand

    2017-11-01

    The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.

  9. DEGRADATION AND PROCESSING OF PLA AND ITS APPLICATION IN FIXATION OF BONE FRACTURE

    Institute of Scientific and Technical Information of China (English)

    HUYushan; BAIDongren; 等

    1999-01-01

    PLA is presently considered as the most attractive compound for temporary therapeutic application in the biomedical field.In this paper we give an overview of the present knowledge on the degradation behavior,processing technology of PLA and its application in the fixation of bone fracture.

  10. Laparoscopic sacrocolpopexy with bone anchor fixation: short-term anatomic and functional results.

    NARCIS (Netherlands)

    Withagen, M.I.J.; Vierhout, M.E.; Mannaerts, G.H.; Weiden, R.M.F. van der

    2012-01-01

    INTRODUCTION AND HYPOTHESIS: The aim of this study was to evaluate short-term anatomic and functional outcomes and safety of laparoscopic sacrocolpopexy with bone anchor fixation. METHODS: A prospective cohort study of women undergoing laparoscopic sacrocolpopexy between 2004 and 2009. Anatomic

  11. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation.

    Science.gov (United States)

    Gunst, S; Del Chicca, F; Fürst, A E; Kuemmerle, J M

    2016-09-01

    There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. Retrospective case series. All horses diagnosed with a central tarsal bone fracture at our institution in 2009-2013 were included. Computed tomography and internal fixation using lag screw technique was performed in all patients. Medical records and diagnostic images were reviewed retrospectively. A clinical and radiographic follow-up examination was performed at least 1 year post operatively. A central tarsal bone fracture was diagnosed in 6 horses. Five were Warmbloods used for showjumping and one was a Quarter Horse used for reining. All horses had sagittal slab fractures that began dorsally, ran in a plantar or plantaromedial direction and exited the plantar cortex at the plantar or plantaromedial indentation of the central tarsal bone. Marked sclerosis of the central tarsal bone was diagnosed in all patients. At long-term follow-up, 5/6 horses were sound and used as intended although mild osteophyte formation at the distal intertarsal joint was commonly observed. Central tarsal bone fractures in nonracehorses had a distinct configuration but radiographically subtle additional fracture lines can occur. A chronic stress related aetiology seems likely. Internal fixation of these fractures based on an accurate diagnosis of the individual fracture configuration resulted in a very good prognosis. © 2015 EVJ Ltd.

  12. Demineralized bone matrix and human cancellous bone enhance fixation of porous-coated titanium implants in sheep

    DEFF Research Database (Denmark)

    Babiker, Hassan; Ding, Ming; Overgaard, Søren

    2016-01-01

    matrix (DBM), alone or in combination with allograft or commercially available human cancellous bone (CB), may replace allografts, as they have the capability of inducing new bone and improving implant fixation through enhancing bone ongrowth. The purpose of this study was to investigate the effect...... of DBM alone, DBM with CB, or allograft on the fixation of porous-coated titanium implants. DBM100 and CB produced from human tissue were included. Both materials are commercially available. DBM granules are placed in pure DBM and do not contain any other carrier. Titanium alloy implants, 10 mm long × 10...... mm diameter, were inserted bilaterally into the femoral condyles of eight skeletally mature sheep. Thus, four implants with a concentric gap of 2 mm were implanted in each sheep. The gap was filled with: (a) DBM; (b) DBM:CB at a ratio of 1:3; (c) DBM:allograft at a ratio of 1:3; or (d) allograft...

  13. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    Science.gov (United States)

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  14. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    Science.gov (United States)

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  15. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    Science.gov (United States)

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  16. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    Science.gov (United States)

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  17. Treatment of midshaft clavicular nonunion with plate fixation and autologous bone grafting

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1995-01-01

    We studied the results of 16 consecutive midshaft clavicular nonunions operated on at the Shoulder and Elbow Clinic during the period from 1990 to 1993. All patients were treated with rigid 3.5 mm plate fixation and autologous cancellous bone grafting. Union of the fractures was achieved in all...... except one case, with a reconstruction ratio (restoration of bone length) of 0.96 (range 0.88 to 1.03). At follow-up 12 of 16 patients had returned to their preinjury activity level and according to the Constant score had obtained an excellent result. Two patients were graded as good, one as fair......, and one had a failure. Thirteen of 16 patients were satisfied with the cosmetic outcome, assessing their cosmetic result as either good or excellent. Rigid plate fixation and restoration of clavicular length with autologous cancellous bone graft is recommended for the treatment of symptomatic clavicular...

  18. Comparative Study Between Coaptive Film Versus Suture For Wound Closure After Long Bone Fracture Fixation

    Directory of Open Access Journals (Sweden)

    IM Anuar Ramdhan

    2013-03-01

    Full Text Available INTRODUCTION: Coaptive film (i.e., Steri-StripsTM is an adhesive tape used to replace sutures in wound closure. The use of coaptive film for wound closure after long bone fracture fixation has not been well documented in the literature. METHODS: The aim of this prospective, randomized controlled trial comparing coaptive film with sutures for wound closure after long bone fracture fixation was skin closure time, incidence of wound complications and scar width at 12 week follow-up. Forty-five patients underwent femur fracture fixation (22 patients’ wound closed with sutures, 23 with coaptive film. RESULTS: The mean time for skin closure using coaptive film was 171.13 seconds compared to 437.27 seconds using suture. The mean wound lengths in the coaptive film group and suture group were 187.65 mm and 196.73 mm, respectively. One patient in each group had wound complications. CONCLUSION: Coaptive film is a time-saving procedure for skin closure following long bone fracture fixation. There is no difference in the incidence of wound complications and scar width between these two methods of skin closure.

  19. Internal Fixation of Cervical Fractures in Three Horses.

    Science.gov (United States)

    Rossignol, Fabrice; Brandenberger, Olivier; Mespoulhes-Rivière, Céline

    2016-01-01

    To describe the surgical treatment outcome of cervical fractures in 3 horses. Case report. Three client-owned horses with cervical vertebral fractures. Three horses were refered for neck stiffness, pain, and ataxia after a cervical trauma because of a fall. Radiographic examination showed an oblique displaced fracture of the caudal aspect of the body of the second cervical vertebra (C2) in horse 1, an oblique displaced fracture of the caudal aspect of C4 involving the disc between C4 and C5 in horse 2, and a displaced transverse fracture of the body of the axis (C2) extending to the lateral arches and involving the vertebral canal in horse 3. In horse 1, the fracture was reduced and stabilized using a 14-hole narrow DCP plate, applied ventrally, and fixed with cancellous screws. A cervical fusion was performed. In horses 2 and 3, fracture fixation was performed using a 5-hole narrow LCP and 5 mm locking screws. All horses showed improvement and returned to full activity. The fracture healed in all horses. Internal fixation of cervical fracture in these horses was associated with minimal complications, and was associated with healing and a highly functional outcome in all horses. The LCP was preferred and would be recommended for ventral stabilization of selected cases of vertebral fractures. © Copyright 2015 by The American College of Veterinary Surgeons.

  20. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    Science.gov (United States)

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  1. External fixation of femoral defects in athymic rats: Applications for human stem cell implantation and bone regeneration

    Directory of Open Access Journals (Sweden)

    Terasa Foo

    2013-01-01

    Full Text Available An appropriate animal model is critical for the research of stem/progenitor cell therapy and tissue engineering for bone regeneration in vivo. This study reports the design of an external fixator and its application to critical-sized femoral defects in athymic rats. The external fixator consists of clamps and screws that are readily available from hardware stores as well as Kirschner wires. A total of 35 rats underwent application of the external fixator with creation of a 6-mm bone defect in one femur of each animal. This model had been used in several separate studies, including implantation of collagen gel, umbilical cord blood mesenchymal stem cells, endothelial progenitor cells, or bone morphogenetic protein-2. One rat developed fracture at the proximal pin site and two rats developed deep tissue infection. Pin loosening was found in nine rats, but it only led to the failure of external fixation in two animals. In 8 to 10 weeks, various degrees of bone growth in the femoral defects were observed in different study groups, from full repair of the bone defect with bone morphogenetic protein-2 implantation to fibrous nonunion with collagen gel implantation. The external fixator used in these studies provided sufficient mechanical stability to the bone defects and had a comparable complication rate in athymic rats as in immunocompetent rats. The external fixator does not interfere with the natural environment of a bone defect. This model is particularly valuable for investigation of osteogenesis of human stem/progenitor cells in vivo.

  2. Removal of internal fixation--the effect on patients' complaints: a study of 66 cases of removal of internal fixation after malleolar fractures

    DEFF Research Database (Denmark)

    Jacobsen, S; Honnens de Lichtenberg, M; Jensen, C M

    1994-01-01

    To estimate the effect of removal of internal fixation after treatment of malleolar fractures on postoperatively presented complaints, we retrospectively evaluated 66 patients by their records and by personal questionnaires. Of all the patients, 89.4% had one or more complaints. These were...... typically soreness over implant and cicatrix, reduced movement of the ankle joint, and strain-related pain. About 75% of these patients reported improvement after removal. The AO mode of fixation, i.e., typically by lateral semitubular plating and transsyndesmotic screw and a medial screw or pins...... period. We conclude that removal of internal fixation after malleolar fractures is indicated when common types of complaints are presented....

  3. Analysis of clinical efficacy and complications of titanium mini plate internal fixation and reconstructive surgery for patients with orbital fracture

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-07-01

    Full Text Available AIM: To analyze the clinical efficacy and complications of titanium mini plate internal fixation and reconstructive surgery for patients with orbital fracture. METHODS: Fifty-seven cases(60 eyeswith orbital fracture from March 2013 to April 2014 in our hospital were researched. According to the random number table method, the patients were divided into observation group(29 cases with 30 eyesand control group(28 cases with 30 eyes. The control group was treated with hydroxyapatite artificial bone plate for internal fixation, and the observation group with titanium mini plate internal fixation and reconstructive surgery. The diplopia grading, grading of ocular movement disorder before and at 1, 3mo after treatment and postoperative complications(prolapse, dislocation, infectionwere compared between the two groups. RESULTS: In both group, all the 60 eyes were healed without scar formation. The rate of diplopia grading as grade 0 1mo postoperatively of observation group and the control groups were 63% and 40%(PPPCONCLUSION: The clinical curative effect of titanium mini plate internal fixation and reconstructive surgery has a good effect for orbital fractures, which can improve the therapeutic effect and reduce the incidence of adverse reactions.

  4. A financial analysis of maxillomandibular fixation versus rigid internal fixation for treatment of mandibular fractures.

    Science.gov (United States)

    Schmidt, B L; Kearns, G; Gordon, N; Kaban, L B

    2000-11-01

    The aim of this study was to compare the cost-effectiveness of mandibular fracture treatment by closed reduction with maxillomandibular fixation (CRF) with open reduction and rigid internal fixation (ORIF). This was a retrospective study of 85 patients admitted to the Oral and Maxillofacial Surgery Service at San Francisco General Hospital and treated for mandibular fractures from January 1 to December 31, 1993. The patients were divided into 2 groups: 1) those treated with CRF and 2) those treated with ORIF. The outcome variables were length of hospital stay, duration of anesthesia, and time in operating room. The charge for primary fracture treatment included the fees for the operation and hospitalization without any complications. Within the group of 85 patients treated for mandibular fractures in 1993, 10 patients treated with CRF and 10 patients treated with ORIF were randomly selected, and hospital billing statements were used to estimate the average charge of primary treatment. The average charge to manage a major postoperative infection also was estimated based on the billing statements of 10 randomly selected patients treated in 1992 (5 treated with CRF, 5 with ORIF) who required hospital admission for the management of a complication. The average total charge was computed by using the average charge for primary treatment plus the incidence of postoperative infection multiplied by the average charge for management of that complication. Eighty-five patients were included in the study. The average charge for primary treatment was $10,100 for the CRF group and $28,362 for the ORIF group. The average charge for the inpatient management of a major postoperative infection was $26,671 for the CRF group and $39,213 for the ORIF group. The average total charge for management of a mandible fracture with CRF was $10,927; the total charge for the ORIF group was $34,636. The results of this retrospective study suggest that the use of CRF in the management of mandibular

  5. Bioreactor activated graft material for early implant fixation in bone

    DEFF Research Database (Denmark)

    Snoek Henriksen, Susan; Ding, Ming; Overgaard, Søren

    2011-01-01

    from the iliac crest. For both groups, mononuclear cells were isolated, and injected into a perfusion bioreactor (Millenium Biologix AG, Switzerland). Scaffold granules (Ø~900-1500 µm, ~88% porosity) in group 1, consisted of hydroxyapatite (HA, 70%) with β-tricalcium-phosphate (β-TCP, 30%) (Danish....... The superficial part was used for mechanical testing and micro-CT scanning, and the profound part for histomorphometry. Push-out tests were performed on an 858 Bionix MTS hydraulic materials testing machine (MTS Systems Corporation, USA). Shear mechanical properties between implant and newly generated bone were...

  6. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    Science.gov (United States)

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Clinical use of computed tomography and surface markers to assist internal fixation within the equine hoof.

    Science.gov (United States)

    Gasiorowski, Janik C; Richardson, Dean W

    2015-02-01

    To describe clinical use of computed tomography (CT) and hoof surface markers to facilitate internal fixation within the confines of the hoof wall. Retrospective case series. Horses (n = 16) that had CT-guided internal fixation of the distal phalanx (DP) or distal sesamoid bone (DSB). Drill bit entry point and direction were planned from CT image series performed on hooves with grids of barium paste dots at proposed entry and projected exit sites. Post-implantation CT images were obtained to check screw position and length as well as fracture reduction. Imaging, reduction, and surgical and general anesthesia times were evaluated. Outcome was recorded. Screw position and length were considered near optimal in all horses, with no consequential malposition of bits or screws. Fracture reduction was evident in all cases. Preoperative planning times (at least 2 CT image acquisitions and grid creation) ranged from 10 to 20 minutes. Surgery time ranged from 45 to 90 minutes (mean, 61 minutes) and general anesthesia time ranged from 115 to 220 minutes (mean, 171 minutes). The combination of CT and surface marker grids allowed accurate positioning of screws in clinical DP and DSB fractures. The technique was simple and rapid. An aiming device is useful for the technique. © Copyright 2014 by The American College of Veterinary Surgeons.

  8. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    injury. Four patients had a longer recovery period due to stiffness, associated wrist fracture and elbow dislocation. The CaSO4 bone substitute was replaced by normal appearing trabecular bone texture at an average of 6 months in all patients. In our experience, we have found the use of locking plates, calcium sulphate bone substitute and tuberosity repair with high-strength sutures to be a safe and reliable method of internal fixation for complex proximal humeral fractures and fracture-dislocations. Furthermore, we have also found the use of the extended deltoid-splitting approach to be safe and to provide excellent exposure facilitating accurate reduction for fixation of the fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Distraction osteogenesis using combined locking plate and Ilizarov fixator in the treatment of bone defect: A report of 2 cases

    Directory of Open Access Journals (Sweden)

    John Mukhopadhaya

    2017-01-01

    Full Text Available Distraction osteogenesis and bone transport has been used to reconstruct bone loss defect by allowing new bone to form in the gap. Plate-guided bone transport has been successfully described in literature to treat bone loss defect in the femur, tibia, and mandible. This study reports two cases of fracture of femur with segmental bone loss treated with locking plate fixation and bone transport with Ilizarov ring fixator. At the time of docking, when the transport segment is compressed with bone fragment, the bone fragment is fixed with additional locking or nonlocking screws through the plate. The bone defect size was 7 cm in case 1 and 8 cm in case 2 and the external fixation indexes were 12.7 days/cm and 14 days/cm. No shortening was present in either of our cases. The average radiographic consolidation index was 37 days/cm. Both cases achieved infection-free bone segment regeneration and satisfactorily functional outcome. This technique reduces the duration of external fixation during the consolidation phase, allows correction of length and alignment and provides earlier rehabilitation.

  10. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    Science.gov (United States)

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  11. Coupled external fixator and skin flap transposition for treatment of exposed and nonunion bone.

    Science.gov (United States)

    Zhao, Yong-gang; Ding, Jing; Wang, Neng

    2011-02-01

    To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones. The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients, whose age were between 19-52 years and averaged 28 years. There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition. Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months after operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence. The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.

  12. 3D perfusion bioreactor-activated porous granules on implant fixation and early bone formation in sheep

    DEFF Research Database (Denmark)

    Ding, Ming; Snoek Henriksen, Susan; Martinetti, Roberta

    2017-01-01

    allograft, granules, granules with bone marrow aspirate or bioreactor-activated graft material. Following an observation time of 6 weeks, early implant fixation and bone formation were assessed by micro-CT scanning, mechanical testing, and histomorphometry. Bone formations were seen in all groups, while......, bone formation was observed in all groups, while the bioreactor-activated graft material did not reveal additional effects on early implant fixation comparable to allograft in this model. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2016....

  13. Influence of bone density on the cement fixation of femoral hip resurfacing components.

    Science.gov (United States)

    Bitsch, Rudi G; Jäger, Sebastian; Lürssen, Marcus; Loidolt, Travis; Schmalzried, Thomas P; Clarius, Michael

    2010-08-01

    In clinical outcome studies, small component sizes, female gender, femoral shape, focal bone defects, bad bone quality, and biomechanics have been associated with failures of resurfacing arthroplasties. We used a well-established experimental setup and human bone specimens to analyze the effects of bone density on cement fixation of femoral hip resurfacing components. Thirty-one fresh frozen femora were prepared for resurfacing using the original instruments. ASR resurfacing prostheses were implanted after dual-energy X-ray densitometer scans. Real-time measurements of pressure and temperature during implantation, analyses of cement penetration, and measurements of micro motions under torque application were performed. The associations of bone density and measurement data were examined calculating regression lines and multiple correlation coefficients; acceptability was tested with ANOVA. We found significant relations between bone density and micro motion, cement penetration, cement mantle thickness, cement pressure, and interface temperature. Mean bone density of the femora was 0.82 +/- 0.13 g/cm(2), t-score was -0.7 +/- 1.0, and mean micro motion between bone and femoral resurfacing component was 17.5 +/- 9.1 microm/Nm. The regression line between bone density and micro motion was equal to -56.7 x bone density + 63.8, R = 0.815 (p density scans are most helpful for patient selection in hip resurfacing, and a better bone quality leads to higher initial component stability. A sophisticated cementing technique is recommended to avoid vigorous impaction and incomplete seating, since increasing bone density also results in higher cement pressures, lower cement penetration, lower interface temperatures, and thicker cement mantles. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss

    NARCIS (Netherlands)

    Tomaszewski, P. M.; van Diest, M.; Bulstra, S. K.; Verdonschot, N.; Verkerke, G. J.

    2012-01-01

    Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system. Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining

  15. The effect of infection and lag screw fixation on revascularization and new bone deposition in membranous bone grafts in a rabbit model.

    Science.gov (United States)

    Fialkov, J A; Phillips, J H; Walmsley, S L; Morava-Protzner, I

    1996-08-01

    We have suggested that rigid fixation of membranous bone grafts in the presence of infection may improve graft-recipient bone union by facilitating graft revascularzation. To test this hypothesis, we grafted autogenous membranous bone grafts to the mandibles of 94 New Zealand White rabbits. Lag screw fixation was applied in half the animals. The wounds were inoculated with a range of Staphylococcus aureus doses. Infected and noninfected rabbits were injected weekly over a 5-week course with fluorescein bone markers and with a marker of vascular endothelium (procion red) just prior to sacrifice. Revascularization and new bone deposition in the grafts were then quantified histologically for the 75 rabbits available for data collection. Infection decreased the amount of graft revascularized and the amount of new bone deposited for both rigidly fixated and nonfixated grafts. Grafts fixated with a lag screw showed a greater amount of revascularization and new bone deposition in the presence and absence of infection when compared with nonfixated grafts, supporting the hypothesis that rigid fixation of membranous bone grafts in the presence of infection may promote graft survival and union by improving revascularization and osteogenesis within the graft.

  16. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  17. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle.

    Science.gov (United States)

    Aquilina, Peter; Chamoli, Uphar; Parr, William C H; Clausen, Philip D; Wroe, Stephen

    2013-06-01

    The most stable pattern of internal fixation for fractures of the mandibular condyle is a matter for ongoing discussion. In this study we investigated the stability of three commonly used patterns of plate fixation, and constructed finite element models of a simulated mandibular condylar fracture. The completed models were heterogeneous in the distribution of bony material properties, contained about 1.2 million elements, and incorporated simulated jaw-adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. This model was considerably larger and more complex than previous finite element models that have been used to analyse the biomechanical behaviour of differing plating techniques. The use of two parallel 2.0 titanium miniplates gave a more stable configuration with lower mean element stresses and displacements over the use of a single miniplate. In addition, a parallel orientation of two miniplates resulted in lower stresses and displacements than did the use of two miniplates in an offset pattern. The use of two parallel titanium plates resulted in a superior biomechanical result as defined by mean element stresses and relative movement between the fractured fragments in these finite element models. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Managing AVN following internal fixation: treatment options and clinical results.

    Science.gov (United States)

    Hoskinson, Simon; Morison, Zachary; Shahrokhi, Shahram; Schemitsch, Emil H

    2015-03-01

    Avascular necrosis (AVN) after internal fixation of intracapsular hip fractures is a progressive multifactorial disease that ultimately results in local ischemia with ensuing osteocyte necrosis and structural compromise. This disease can cause significant clinical morbidity and affects patients of any age, including young and active patients. Effective treatment of this condition among young adults is challenging due to their high functional demands. The aim of managing AVN is to relieve pain, preserve range of movement and improve function. Treatment methods vary depending on the stage of the disease and can be broadly categorised into two options, hip preserving surgery and hip arthroplasty. Although, hip preserving techniques are attractive in the young adult, they may alter the morphology of the proximal femur and make subsequent arthroplasty more challenging. Conversely, arthroplasty in the young adult may require repeat revision procedures throughout the patient's life. Current evidence suggests that modifications of prevailing treatments, in addition to new technologies, have led to the development of management strategies that may be able to alter the course of femoral head osteonecrosis. This review aims to summarise the options available for treatment of AVN in the young adult and review the clinical results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis

    OpenAIRE

    Zhang, Shaobo; Zhang, Yibao; Wang, Shenghong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-01-01

    Purpose: To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. Methods: We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the ...

  20. Necrotizing fasciitis after internal fixation of fracture of femoral trochanteric ? ??

    OpenAIRE

    Santos, Leandro Em?lio Nascimento; Pires, Robinson Esteves Santos; Figueiredo, Leonardo Brand?o; Soares, Eduardo Augusto Marques

    2014-01-01

    Necrotizing fasciitis is a rare and potentially lethal soft tissue infection. We report a case of trochanteric femur fracture in a patient who underwent fracture fixation and developed necrotizing fasciitis. A literature review on the topic will be addressed.

  1. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    Directory of Open Access Journals (Sweden)

    Samir Joshi

    2015-01-01

    Full Text Available Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  2. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    Science.gov (United States)

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  3. Efficacy of a small cell-binding peptide coated hydroxyapatite substitute on bone formation and implant fixation in sheep

    DEFF Research Database (Denmark)

    Ding, Ming; Andreasen, Christina Møller; Dencker, Mads L.

    2015-01-01

    hydroxyapatite (ABM/P-15); hydroxyapatite + βtricalciumphosphate+ Poly-Lactic-Acid (HA/βTCP-PDLLA); or ABM/P-15+HA/βTCP-PDLLA. After nine weeks, bone-implant blocks were harvested and sectioned for micro-CT scanning, push-out test, and histomorphometry. Significant bone formation and implant fixation could...

  4. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    Science.gov (United States)

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Open reduction and internal fixation: Screw injury - Retrospective study

    Directory of Open Access Journals (Sweden)

    Preetha Balaji

    2017-01-01

    Full Text Available Background/Aims: Open reduction and internal fixation (ORIF is a standard surgical procedure in jaw trauma and in orthognathic surgery. Insertion of screws is a significant risk for accidental tooth root injury with varying outcomes. Contrary evidences are found in literature due to a variety of study designs. This study was undertaken to address the lacunae and possibly estimate the difference in occurrence of tooth damage during or after ORIF between trauma and planned osteotomies. Materials and Methods: In this retrospective study, the data of ORIF in either trauma or orthognathic surgery fulfilling inclusion and exclusion criteria were collected and analyzed. Results: There were 1632 patients fulfilling the inclusion and exclusion criteria and formed the study group, of which 663 were in orthognathic surgery, of whom 210 had bimaxillary orthognathic surgery. In the trauma group, 358 patients had fractures involving both jaws whereas 272 had maxilla alone and 339 had mandibular fractures alone. On comparing the outcome, of the 9073 screws studied, 93.40% were not involved in any contact with the teeth, 6.3% were in category of potential hits (near apices or the root surfaces, and only 0.28% had evidence of root damage with the screws. It is observed that molar and premolar had a significant difference in terms of the type of surgery (P ≤ 0.05 whereas canine (P = 0.75 and incisor (P = 0.67 showed no statistical difference. Conclusion: ORIF when used as mentioned is a safe way for the management of fractures. The incidence of root injury is not uncommon but can be avoided with careful planning and execution.

  6. The prediction of cyclic proximal humerus fracture fixation failure by various bone density measures.

    Science.gov (United States)

    Varga, Peter; Grünwald, Leonard; Windolf, Markus

    2018-02-22

    Fixation of osteoporotic proximal humerus fractures has remained challenging, but may be improved by careful pre-operative planning. The aim of this study was to investigate how well the failure of locking plate fixation of osteoporotic proximal humerus fractures can be predicted by bone density measures assessed with currently available clinical imaging (realistic case) and a higher resolution and quality modality (theoretical best-case). Various density measures were correlated to experimentally assessed number of cycles to construct failure of plated unstable low-density proximal humerus fractures (N = 18). The influence of density evaluation technique was investigated by comparing local (peri-implant) versus global evaluation regions; HR-pQCT-based versus clinical QCT-based image data; ipsilateral versus contralateral side; and bone mineral content (BMC) versus bone mineral density (BMD). All investigated density measures were significantly correlated with the experimental cycles to failure. The best performing clinically feasible parameter was the QCT-based BMC of the contralateral articular cap region, providing significantly better correlation (R 2  = 0.53) compared to a previously proposed clinical density measure (R 2  = 0.30). BMC had consistently, but not significantly stronger correlations with failure than BMD. The overall best results were obtained with the ipsilateral HR-pQCT-based local BMC (R 2  = 0.74) that may be used for implant optimization. Strong correlations were found between the corresponding density measures of the two CT image sources, as well as between the two sides. Future studies should investigate if BMC of the contralateral articular cap region could provide improved prediction of clinical fixation failure compared to previously proposed measures. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle.

    Science.gov (United States)

    Ramanujam, Crystal L; Zgonis, Thomas

    2017-01-01

    Diabetic Charcot neuroarthropathy (DCN) of the foot and ankle is a challenging disease with regard to clinical presentation, pathogenesis, and prognosis. Its surgical management is equally difficult to interpret based on the wide array of options available. In the presence of an ulceration or concomitant osteomyelitis, internal fixation by means of screws, plates, or intramedullary nailing needs to be avoided when feasible. External fixation becomes a great surgical tool when managing DCN with concomitant osteomyelitis. This article describes internal and external fixation methods along with available literature to enlighten surgeons faced with treating this complex condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    Science.gov (United States)

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  9. Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses

    Directory of Open Access Journals (Sweden)

    Rina Sakai

    2014-01-01

    Full Text Available It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate. Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (P<0.05. No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.

  10. The effect of infection and lag screw fixation on the union of membranous bone grafts in a rabbit model.

    Science.gov (United States)

    Fialkov, J A; Phillips, J H; Walmsley, S L

    1994-03-01

    Infection complicating craniofacial procedures contributes significantly to patient morbidity and health care costs. The role of fixation materials in this setting remains unclear. As foreign material, does fixation hardware increase patients' susceptibility to developing postoperative infection? Furthermore, once infection is established, should fixation hardware be removed? To answer these questions, we performed an onlay membranous bone grafting procedure to the mandible in 94 New Zealand White rabbits, applied lag-screw fixation in half the animals, and inoculated the wounds with different bacterial doses. We quantified the differential rates of infection and rates of graft union in the presence of infection. The infection rates for the rigidly fixated group were not significantly different from the rates for the nonfixated group for a range of bacterial inoculum doses. There was no significant difference in the rates of resolution of infection and sepsis between the two groups. Gross and histologic assessments revealed a significantly lower union rate for infected grafts when compared with uninfected grafts. Furthermore, grafts rigidly fixated with a lag screw showed a higher rate of union when compared with nonfixated grafts in the presence of infection. In the absence of infection, the union rates for fixated and nonfixated groups did not differ significantly. While fixation hardware has been cited as a risk factor for postoperative infection, we were unable to show that lag-screw fixation contributes to this risk. Although infection impaired the union of membranous bone grafts to the recipient mandible, fixation of the grafts with a lag screw significantly decreased this deleterious effect of infection.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. 3D perfusion bioreactor-activated porous granules on implant fixation and early bone formation in sheep.

    Science.gov (United States)

    Ding, Ming; Henriksen, Susan S; Martinetti, Roberta; Overgaard, Søren

    2017-11-01

    Early fixation of total joint arthroplasties is crucial for ensuring implant survival. An alternative bone graft material in revision surgery is needed to replace the current gold standard, allograft, seeing that the latter is associated with several disadvantages. The incubation of such a construct in a perfusion bioreactor has been shown to produce viable bone graft materials. This study aimed at producing larger amounts of viable bone graft material (hydroxyapatite 70% and β-tricalcium-phosphate 30%) in a novel perfusion bioreactor. The abilities of the bioreactor-activated graft material to induce early implant fixation were tested in a bilateral implant defect model in sheep, with allograft as the control group. Defects were bilaterally created in the distal femurs of the animals, and titanium implants were inserted. The concentric gaps around the implants were randomly filled with either allograft, granules, granules with bone marrow aspirate or bioreactor-activated graft material. Following an observation time of 6 weeks, early implant fixation and bone formation were assessed by micro-CT scanning, mechanical testing, and histomorphometry. Bone formations were seen in all groups, while no significant differences between groups were found regarding early implant fixation. The microarchitecture of the bone formed by the synthetic graft materials resembled that of allograft. Histomorphometry revealed that allograft induced significantly more bone and less fibrous tissue (p formation was observed in all groups, while the bioreactor-activated graft material did not reveal additional effects on early implant fixation comparable to allograft in this model. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2465-2476, 2017. © 2016 Wiley Periodicals, Inc.

  12. Relationships between head fixation pins for radiosurgery and the skull bone. Usefulness of a torque wrench

    International Nuclear Information System (INIS)

    Toyota, Shun; Seta, Hidetoshi; Muramatsu, Masatoshi; Kubo, Hitoshi; Takeda, Kan

    2003-01-01

    In stereotactic radiosurgery (SRS), fixation devices are secured to the patient's head with pins. However, there have been no standards for the use of such pins, which must be inserted with appropriate torque based on the surgeon's clinical judgment. Therefore, the pins may sometimes be tightened excessively and penetrate too deeply into the patient's skull. To improve safety in SRS, a torque wrench was used for pin insertion. The usefulness of the torque wrench was then evaluated by examining the relationships between the pins and skull bone and identifying differences according to the wrench used and the patient's bone thickness. CT images of patients who had previously undergone SRS were used to assess the relationships between the pins and skull bone. Differences according to the wrench used and pin insertion site were investigated. Compared with a standard wrench, use of the torque wrench decreased the insertion depth of pins in the skull bone. In terms of site, pins in the forehead were inserted more deeply. No differences related to the frontal sinus were observed. The use of a torque wrench improved safety during pin insertion for SRS procedures. (author)

  13. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins under epidural anesthesia].

    Science.gov (United States)

    Liu, Jinliang; Li, Keyao; Ju, Zhenlong; Bai, Yan

    2011-03-01

    To study the indications, methods and experience of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. 52 cases with multiple rib fractures were performed internal fixation with absorbable rib-connecting-pins under epidural anesthesia. All cases were followed up for 1 to 12 months, with an average of 5 months. All fractures were achieved healing in 3 to 6 months after the operation and were not found chest wall deformity. Absorbable rib-connecting-pins fixation is a simple and effective method and worthies recommending to perform operation for the appropriate cases with multiple rib fractures.

  14. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    Science.gov (United States)

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (Pexternal fixation with limited internal fixation in the treatment of Pilon fracture

  15. Internal bone transport using a cannulated screw as a mounting device in the treatment of a post-infective ulnar defect.

    Science.gov (United States)

    Tsitskaris, Konstantinos; Havard, Heledd; Bijlsma, Paulien; Hill, Robert A

    2016-04-01

    Bone transport techniques can be used to address the segmental bone loss occurring after debridement for infection. Secure fixation of the bone transport construct to the bone transport segment can be challenging, particularly if the bone is small and osteopenic. We report a case of a segmental ulnar bone defect in a young child treated with internal bone transport using a cannulated screw as the mounting device. We found this technique particularly useful in the treatment of bone loss secondary to infection, where previous treatment and prolonged immobilisation had led to osteopenia. This technique has not been previously reported.

  16. A Paradigm for the Development and Evaluation of Novel Implant Topologies for Bone Fixation: In Vivo Evaluation

    OpenAIRE

    Long, Jason P.; Hollister, Scott J.; Goldstein, Steven A.

    2012-01-01

    While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopaedic implants and then fabricated select...

  17. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  18. Limitations of using micro-computed tomography to predict bone-implant contact and mechanical fixation.

    Science.gov (United States)

    Liu, S; Broucek, J; Virdi, A S; Sumner, D R

    2012-01-01

    Fixation of metallic implants to bone through osseointegration is important in orthopaedics and dentistry. Model systems for studying this phenomenon would benefit from a non-destructive imaging modality so that mechanical and morphological endpoints can more readily be examined in the same specimens. The purpose of this study was to assess the utility of an automated microcomputed tomography (μCT) program for predicting bone-implant contact (BIC) and mechanical fixation strength in a rat model. Femurs in which 1.5-mm-diameter titanium implants had been in place for 4 weeks were either embedded in polymethylmethacrylate (PMMA) for preparation of 1-mm-thick cross-sectional slabs (16 femurs: 32 slabs) or were used for mechanical implant pull-out testing (n= 18 femurs). All samples were scanned by μCT at 70 kVp with 16 μm voxels and assessed by the manufacturer's software for assessing 'osseointegration volume per total volume' (OV/TV). OV/TV measures bone volume per total volume (BV/TV) in a 3-voxel-thick ring that by default excludes the 3 voxels immediately adjacent to the implant to avoid metal-induced artefacts. The plastic-embedded samples were also analysed by backscatter scanning electron microscopy (bSEM) to provide a direct comparison of OV/TV with a well-accepted technique for BIC. In μCT images in which the implant was directly embedded within PMMA, there was a zone of elevated attenuation (>50% of the attenuation value used to segment bone from marrow) which extended 48 μm away from the implant surface. Comparison of the bSEM and μCT images showed high correlations for BV/TV measurements in areas not affected by metal-induced artefacts. In addition for bSEM images, we found that there were high correlations between peri-implant BV/TV within 12 μm of the implant surface and BIC (correlation coefficients ≥0.8, p implant pull-out strength (r= 0.401, p= 0.049) and energy to failure (r= 0.435, p= 0.035). Thus, the need for the 48-μm-thick exclusion

  19. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  20. Distal femoral osteotomy in genovalgum: internal fixation with blade plate versus casting.

    Science.gov (United States)

    Makhmalbaf, Hadi; Moradi, Ali; Ganji, Saeid

    2014-10-01

    To compare the results of two different ways of distal femoral osteotomy stabilization in patients suffering from genuvalgum: internal fixation with plate, and casting. In a non-randomized prospective study, after distal femoral osteotomy with the zigzag method, patients were divided into two groups: long leg casting, and internal fixation with blade plate. For all patients, questionnaires were filled to obtain data. Information such as range of motion, tibiofemoral anatomical angle and complications were recorded. 38 knees with valgus deformity underwent distal femoral supracondylar osteotomy. (8 with plaster cast and 30 with internal fixation using a blade plate). Preoperative range of motion was 129±6° and six months later it was 120±14°. The preoperative tibiofemoral angle was 32±6°; postoperative tibiofemoral angles were 3±3°, 6±2°, and 7±3° just after operation, six months, and two years later, respectively. Although this angle was greater among the group stabilized with a cast, this difference was not statistically significant. In postoperative complications, over-correction was found in five, recorvatom deformity in one, knee stiffness in three and superficial wound infection was recorded in three knees. There is no prominent difference in final range of motion and alignment whether fixation is done with casting or internal fixation. However, the complication rate seems higher in the casting method.

  1. In Vitro Corrosion Assessment of Additively Manufactured Porous NiTi Structures for Bone Fixation Applications

    Directory of Open Access Journals (Sweden)

    Hamdy Ibrahim

    2018-03-01

    Full Text Available NiTi alloys possess distinct functional properties (i.e., shape memory effect and superelasticity and biocompatibility, making them appealing for bone fixation applications. Additive manufacturing offers an alternative method for fabricating NiTi parts, which are known to be very difficult to machine using conventional manufacturing methods. However, poor surface quality, and the presence of impurities and defects, are some of the major concerns associated with NiTi structures manufactured using additive manufacturing. The aim of this study is to assess the in vitro corrosion properties of additively manufactured NiTi structures. NiTi samples (bulk and porous were produced using selective laser melting (SLM, and their electrochemical corrosion characteristics and Ni ion release levels were measured and compared with conventionally fabricated NiTi parts. The additively manufactured NiTi structures were found to have electrochemical corrosion characteristics similar to those found for the conventionally fabricated NiTi alloy samples. The highest Ni ion release level was found in the case of 50% porous structures, which can be attributed to their significantly higher exposed surface area. However, the Ni ion release levels reported in this work for all the fabricated structures remain within the range of most of values for conventionally fabricated NiTi alloys reported in the literature. The results of this study suggest that the proposed SLM fabrication process does not result in a significant deterioration in the corrosion resistance of NiTi parts, making them suitable for bone fixation applications.

  2. Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study.

    Science.gov (United States)

    Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn

    2018-03-20

    Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.

  3. Treatment of Early Post-Op Wound Infection after Internal Fixation

    Science.gov (United States)

    2016-10-01

    Obremskey, M.D. CONTRACTING ORGANIZATION: Vanderbilt University Medical Center Nashville TN 37203 REPORT DATE: October 2016 TYPE OF REPORT: Annual...NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) October 2016 2. REPORT TYPE Annual 3. DATES COVERED (From - To) 15Sep2015...effect of treatment of post-op wound infection in long bones after fracture fixation or joint fusion and either: (Group 1) operative debridement and

  4. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook [Asan Medical CenterUniversity of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Ji Wan [Dept. of Orthopedic Surgery, Haeundae Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-03-15

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.

  5. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative SPECT/CT

    International Nuclear Information System (INIS)

    Han, Sang Won; Oh, Min Young; Yoon, Seok Ho; Kim, Jin Soo; Chang, Jae Suk; Ryu, Jin Sook; Kim, Ji Wan

    2017-01-01

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2–10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients

  6. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    Science.gov (United States)

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  7. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  8. Osteogenic protein-1 increases the fixation of implants grafted with morcellised bone allograft and ProOsteon bone substitute: an experimental study in dogs

    DEFF Research Database (Denmark)

    Jensen, T B; Overgaard, S; Lind, M

    2007-01-01

    Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules...... (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant...... surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1. After three...

  9. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    Science.gov (United States)

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  10. The role of bone SPECT/CT in the evaluation of lumbar spinal fusion with metallic fixation devices

    DEFF Research Database (Denmark)

    Damgaard, Morten; Nimb, Lars; Madsen, Jan L

    2010-01-01

    PURPOSE: It is difficult to evaluate the stability of the lumbar spondylodesis with metallic fixation devices by conventional imaging methods such as radiography or magnetic resonance imaging. It is unknown whether single photon emission computed tomography/computed tomography (SPECT/CT) may......, whereas in 1 case loose pedicle screws were detected at a wrong vertebral level. CONCLUSION: SPECT/CT may be useful to detect a lack of fixation of the metallic implants, and hence instability of the spondylodesis by evaluating the focal bone mineralization activity in relation to the pedicle screws....

  11. Management of Subcondylar Fracture through Intraoral Approach with Rigid Internal Fixation.

    Science.gov (United States)

    Patil, Ravi S; Gudi, Santosh S

    2011-09-01

    In Oral and Maxillofacial Surgery, the majority of the condylar fractures are treated by closed reduction with generally satisfactory long term results. But in such cases of closed reduction, patient will be uncomfortable owing to long term application of inter maxillary fixation (IMF). Where as, Disadvantages of extra oral open reduction and fixation of condylar fracture includes facial nerve damage, facial scars etc. which are surely eliminated by the intraoral reduction and rigid fixation. The present study was conducted to determine the efficacy of reduction and fixation of low sub-condylar fractures through intra-oral approach. In this study, ten patients with low sub-condylar fracture, reported to department of Oral and Maxillofacial Surgery. P.M.N.M. Dental College and Hospital Bagalkot were included. These patients were treated by open reduction and internal fixation through intra-oral approach. All the patients were evaluated postoperatively for mouth opening, occlusion and mandibular deviation with regular radiographic examination for 6 weeks. All operated patients followed for 6 weeks, maximum mouth opening was more than 40 mm in seven patients (range from 40 to 50 mm) and less than 40 mm in three patients. Occlusion was satisfactory in all and none of the patients showed deviation of mandible on mouth opening. Statistical analysis showed that postoperative mouth opening was significant ('t' value = 7.88, 'P' = (0.000) value = 1.96, 'P' value (0.081), 0.05]. For occlusion standard photographs were obtained at sixth week and found minor occlusal corrections in two patients are treated by elastic traction for few days. Open reduction with internal fixation through intraoral approach has proved to be safe for early function and also effective by avoiding the patient discomfort due to long term intermaxillary fixation, psychological effect, facial nerve damage, facial scar and weight loss.

  12. Effects of Low-Dose Microwave on Healing of Fractures with Titanium Alloy Internal Fixation: An Experimental Study in a Rabbit Model

    Science.gov (United States)

    Zhang, Han; Fu, Tengfei; Jiang, Lan; Bai, Yuehong

    2013-01-01

    Background Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tissues. Comparing with traditional medical stainless steel, titanium alloy is a kind of medical implants with low magnetic permeability and electric conductivity. But the effects of microwave treatment on fracture with titanium alloy internal fixation in vivo were not reported. The aim of this article was to evaluate the security and effects of microwave on healing of a fracture with titanium alloy internal fixation. Methods Titanium alloy internal fixation systems were implanted in New Zealand rabbits with a 3.0 mm bone defect in the middle of femur. We applied a 30-day microwave treatment (2,450MHz, 25W, 10 min per day) to the fracture 3 days after operation. Temperature changes of muscle tissues around implants were measured during the irradiation. Normalized radiographic density of the fracture gap was measured on the 10th day and 30th day of the microwave treatment. All of the animals were killed after 10 and 30 days microwave treatment with histologic and histomorphometric examinations performed on the harvested tissues. Findings The temperatures did not increase significantly in animals with titanium alloy implants. The security of microwave treatment was also supported by histology of muscles, nerve and bone around the implants. Radiographic assessment, histologic and histomorphometric examinations revealed significant improvement in the healing bone. Conclusion Our results suggest that, in the healing of fracture with titanium alloy internal fixation, a low dose of microwave treatment may be a promising method. PMID:24086626

  13. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    Science.gov (United States)

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  14. [Case control study on therapeutic effects of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of Pilon fractures of the proximal interphalangeal joint].

    Science.gov (United States)

    Miao, Dao-yi; Yang, Guo-jing; Zhang, Ling-zhou; Wu, Jian-wei

    2015-10-01

    To compare the clinical effects and safety of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of close Pilon fractures of the proximal interphalangeal joint. From June 2012 to June 2014, totally 41 patients (45 fingers) with close interphalangeal joint Pilon fracture were treated by dynamic external fixtor combined with limited internal fixation or cross K-wires fixation, and all the patients were followed up. In the dynamic external fixtor combined with limited internal fixation group (group A), there were 21 patients with 22 fingers, including 12 males and 9 females, with an average of (30.6±5.6) years old. In the cross K-wires fixation group (group B), there were 20 patients with 23 fingers, including 11 males and 9 females, with an average of (30.1±5.3) years old. Regular re-examination of X-ray was performed to evaluate the active range of joint motion, fracture healing time, infection rate and postoperative joint motion pain. According to the evaluation criteria of upper extremity function issued by the Hand Surgery Society of Chinese Medical Association, the excellent and good cases of group A was up to 19 and 13 for group B. The evaluation results has significant differences (Z=2.558, P=0.011). The excellent and good rate of group A was obviously higher than that of group B. The average bone union time of group A was (7.9±2.1) weeks, and (8.1±2.3) weeks for group B. There was no significant difference on the mean healing time (t=-0.304, P=0.762). The infection fingers of group A was 5, and 1 for group B. The difference between the results was statistically significant (χ2=3.287, Pexternal fixtor combined with limited internal fixation is a reliable and effective method to treat Pilon fractures of the proximal interphalangeal joint. It allows early postoperative functional rehabilitation and restores the joint function.

  15. Complications and functional outcome after internal fixation of dorsally displaced distal radial fractures

    DEFF Research Database (Denmark)

    Bove, Jeppe; Viberg, Bjarke; Wied Greisen, Pernille

    Background: Recently there has been an increasing interest in open reduction and internal fixation of distal radius fractures. Even so further studies are still needed. Purpose: To document the functional outcome and identify complica- tions among patients treated with a volar locking plate (DVR...

  16. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    Science.gov (United States)

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method

  17. Taylor spatial frame fixation in patients with multiple traumatic injuries: study of 57 long-bone fractures.

    Science.gov (United States)

    Sala, Francesco; Elbatrawy, Yasser; Thabet, Ahmed M; Zayed, Mahmoud; Capitani, Dario

    2013-08-01

    To evaluate the Taylor spatial frame (TSF) for primary and definitive fixation of lower limb long-bone fractures in patients with multiple traumatic injuries. Retrospective. Level I trauma center. Consecutive series of 52 patients, 57 fractures (25 femoral and 32 tibial), treated between 2005 and 2009. Forty-nine fractures (86%) were open. Injury Severity Score ≥16 for all patients. Fifty-four fractures (95%) underwent definitive fixation with the TSF and 3 were treated primarily within 48 hours of injury. In 22 cases (39%), fractures were acutely reduced with the TSF, fixed to bone and the struts in sliding mode without further adjustment, and in 35 cases (61%), the total residual deformity correction program was undertaken. Clinical and radiological. Complete union was obtained in 52 fractures (91%) without additional surgery at an average of 29 weeks. Four nonunions and 1 delayed union occurred. Results based on Association for the Study and Application of the Method of Ilizarov criteria: 74% excellent, 16% good, 4% fair, and 7% poor for bone outcomes and 35% excellent, 47% good, and 18% fair for functional outcomes. Eighty-eight percent of patients returned to preinjury work activities. Primary and definitive fixation with the TSF is effective. Advantages include continuity of device until union, reduced risk of infection, early mobilization, restoration of primary defect caused by bone loss, easy and accurate application, convertibility and versatility compared with a monolateral fixator, and improved union rate and range of motion for lower extremity long-bone fractures in patients with multiple traumatic injuries.

  18. The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

    Science.gov (United States)

    Søballe, Kjeld; Mouzin, Olivier R G; Kidder, Louis A; Overgaard, Søren; Bechtold, Joan E

    2003-06-01

    We used our established experimental model of revision joint replacement to examine the roles of hydroxyapatite coating and bone graft in improving the fixation of revision implants. The revision protocol uses the Søballe micromotion device in a preliminary 8-week period of implant instability for the presence of particulate polyethylene. During this procedure, a sclerotic endosteal bone rim forms, and a dense fibrous membrane is engendered, having macrophages with ingested polyethylene and high levels of inflammatory cytokines. At the time of revision after 8 weeks, the cavity is revised with either a titanium alloy (Ti) or a hydroxyapatite (HA) 6.0 mm plasma-sprayed implant, in the presence or absence of allograft packed into the initial 0.75 mm peri-implant gap. The contralateral limb is subjected to primary surgery with the same implant configuration, and serves as control. 8 implants were included in each of the 8 treatment groups (total 64 implants in 32 dogs). The observation period was 4 weeks after revision. Outcome measures are based on histomorphometry and mechanical pushout properties. The revision setting was always inferior to its primary counterpart. Bone graft improved the revision fixation in all treatment groups, as also did the HA coating. The sole exception was revision-grafted HA implants, which reached the same fixation as primary Ti and HA grafted implants. The revision, which was less active in general, seems to need the dual stimulation of bone graft and HA implant surface, to obtain the same level of fixation associated with primary implants. Our findings suggest that the combination of HA implant and bone graft may be of benefit in the clinical revision implant setting.

  19. Clinical comparison between the retromandibular approach for reduction and fixation and endoscope-assisted open reduction and internal fixation for mandibular condyle fractures.

    Science.gov (United States)

    Nogami, Shinnosuke; Takahashi, Tetsu; Yamauchi, Kensuke; Miyamoto, Ikuya; Kaneuji, Takeshi; Yamamoto, Noriaki; Yoshiga, Daigo; Yamashita, Yoshihiro

    2012-11-01

    Endoscope-assisted transoral open reduction and internal fixation (EAORIF) for mandibular condyle fractures has recently become popular because it is minimally invasive, provides excellent visibility without a large incision, and reduces surgical scarring and the risk of facial nerve injury. This report describes a retrospective clinical study that compared certain clinical parameters, including postoperative function, between the retromandibular (RM) approach and EAORIF. Fifteen patients were treated by the RM approach, whereas 15 underwent EAORIF between July 2006 and September 2011 at Kyushu Dental College, Japan. Clinical indices comprised fracture line, fracture type, number of plates used, surgical duration, bleeding amount, and functional items, including maximum interincisal opening, mandibular deviation on the opening pathway, malocclusion, facial paresthesia, and temporomandibular joint pain and clicking. The areas subjected to either approach included lower neck and subcondyle. The RM approach was used for mandibular condyle fractures with dislocation of a small bone segment. Both groups used 2 plates in all cases. Surgical duration, maximum interincisal opening, mandibular deviation, occlusion, and temporomandibular joint function at 6 months after surgery were comparable between groups. The average bleeding amount in the EAORIF group was greater than in the RM group. One patient from the RM group developed facial paresthesia that persisted for 6 months after surgery. It was concluded that surgical treatment was suitable for fractures of the lower neck and subcondylar. Both procedures showed good results in the functional items of this study.

  20. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  1. Induced membrane technique combined with two-stage internal fixation for the treatment of tibial osteomyelitis defects.

    Science.gov (United States)

    Luo, Fei; Wang, Xiaohua; Wang, Shulin; Fu, Jingshu; Xie, Zhao

    2017-07-01

    The purpose of this study was to observe the effects of induced membrane technique combined with two-stage internal fixation in the treatment of tibial osteomyelitis defects. A retrospective analyses for 67 cases of tibialosteomyelitis defects were admitted to our department between September 2012 to February 2015, which were treated with induced membrane technique. At the first stage, implanted with a PMMA cement spacer in the defects after radical debridement and fixed with reconstructive locked plate. Bone grafting and exchanged the plate with intramedullary nail at the second stage. In current study, all patients were followed up for 18-35 months. Sixty-six patients achieved bone union with the average radiographic and clinical healing times of 5.55±2.19 and 7.45±1.69months, respectively. Seven patients required a second debridement before grafting, while four patients experienced a recurrence of infection or a relapse following second stage treatment. Twelve patients experienced either knee or ankle dysfunctions and 2 patients faced delayed wound healing. Donor site complications includes pain and infection were found in 7 and 3 patients, respectively with delayed stress fracture in 1 patient only. Induced membrane technique for the treatment of tibial osteomyelitis defects, seems a reliable method. The use of reconstructive locked plate as a temporary internal fixation at the first stage and exchanged with intramedullary nail at the second stage, potentially achieves good clinical efficacy. Care should be taken to restore the joint function especially in distal tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. In vitro biomechanical properties of 2 compression fixation methods for midbody proximal sesamoid bone fractures in horses.

    Science.gov (United States)

    Woodie, J B; Ruggles, A J; Litsky, A S

    2000-01-01

    To evaluate 2 methods of midbody proximal sesamoid bone repair--fixation by a screw placed in lag fashion and circumferential wire fixation--by comparing yield load and the adjacent soft-tissue strain during monotonic loading. Experimental study. 10 paired equine cadaver forelimbs from race-trained horses. A transverse midbody osteotomy of the medial proximal sesamoid bone (PSB) was created. The osteotomy was repaired with a 4.5-mm cortex bone screw placed in lag fashion or a 1.25-mm circumferential wire. The limbs were instrumented with differential variable reluctance transducers placed in the suspensory apparatus and distal sesamoidean ligaments. The limbs were tested in axial compression in a single cycle until failure. The cortex bone screw repairs had a mean yield load of 2,908.2 N; 1 limb did not fail when tested to 5,000 N. All circumferential wire repairs failed with a mean yield load of 3,406.3 N. There was no statistical difference in mean yield load between the 2 repair methods. The maximum strain generated in the soft tissues attached to the proximal sesamoid bones was not significantly different between repair groups. All repaired limbs were able to withstand loads equal to those reportedly applied to the suspensory apparatus in vivo during walking. Each repair technique should have adequate yield strength for repair of midbody fractures of the PSB immediately after surgery.

  3. Anterior debridement and fusion followed by posterior pedicle screw fixation in pyogenic spondylodiscitis: autologous iliac bone strut versus cage.

    Science.gov (United States)

    Pee, Yong Hun; Park, Jong Dae; Choi, Young-Geun; Lee, Sang-Ho

    2008-05-01

    An anterior approach for debridement and fusion with autologous bone graft has been recommended as the gold standard for surgical treatment of pyogenic spondylodiscitis. The use of anterior foreign body implants at the site of active infection is still a challenging procedure for spine surgeons. Several authors have recently introduced anterior grafting with titanium mesh cages instead of autologous bone strut in the treatment of spondylodiscitis. The authors present their experience of anterior fusion with 3 types of cages followed by posterior pedicle screw fixation. They also compare their results with the use of autologous iliac bone strut. The authors retrospectively reviewed the cases of 60 patients with pyogenic spondylodiscitis treated by anterior debridement between January 2003 and April 2005. Fusion using either cages or iliac bone struts was performed during the same course of anesthesia followed by posterior fixation. Twenty-three patients underwent fusion with autologous iliac bone strut, and 37 patients underwent fusion with 1 of the 3 types of cages. The infections resolved in all patients, as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. Patients in both groups were evaluated in terms of their preoperative and postoperative clinical and imaging findings. Single-stage anterior debridement and cage fusion followed by posterior pedicle screw fixation can be effective in the treatment of pyogenic spondylodiscitis. There was no difference in clinical and imaging outcomes between the strut group and cage group except for the subsidence rate. The subsidence rate was higher in the strut group than in the cage group. The duration until subsidence was also shorter in the strut group than in the cage group.

  4. An Overview of Internal Fixation Implant Metallurgy and Galvanic Corrosion Effects.

    Science.gov (United States)

    Koh, Justin; Berger, Aaron; Benhaim, Prosper

    2015-08-01

    Orthopedic and hand surgery implants for internal fixation of fractures have evolved substantially over the past 50 years. Newer metal compositions have been used, and new standards have been applied to older alloys, resulting in modern implants with unique physical properties and better clinical performances. Conventional wisdom has long dictated that implanting different metals should be avoided, but few guidelines exist regarding the safety of using in proximity implant systems of dissimilar metals. To better characterize the landscape of internal fixation implant metallurgy, we have compiled the recommendations and conclusions of the currently available and pertinent literature. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. The psychological impact of external fixation using the Ilizarov or Orthofix LRS method to treat tibial osteomyelitis with a bone defect.

    Science.gov (United States)

    Abulaiti, Alimujiang; Yilihamu, Yilizati; Yasheng, Tayierjiang; Alike, Yamuhanmode; Yusufu, Aihemaitijiang

    2017-12-01

    To examine the psychological impact of external fixation for a tibial bone defect due to osteomyelitis, and to compare the Orthofix limb reconstruction system (LRS) with the Ilizarov external fixator. The SCL-90-R questionnaire was administered at four different time points (before surgery, while patients wore the external fixation device, when the device was removed, and two to three months after). The scores at the four time points were compared, as were the two different methods of external fixation (Orthofix LRS vs. Ilizarov). The patients experienced a significant adverse impact on their mental health, with the worst outcomes at Time 2 (while wearing the external fixator), but with some negative effects still present even several months after removal of the fixation device. Although the Orthofix LRS and Ilizarov groups showed similar mental health scores at Time 1 (preoperatively) and Time 3 (upon removal of the fixation device), the Orthofix LRS was associated with better scores, specifically in the Hostility (Time 2), Phobic Anxiety (Time 2), Psychoticism (Times 2 and 4), and Other (Time 2) sub-scores, as well as the total score (Times 2 and 4). Although both Ilizarov and Orthofix LRS fixation resolved the bone defects, external fixation had a negative impact on the patients' mental health, which persisted even after removal of the devices. Although both methods led to negative effects on the patients' mental, the impact of the Orthofix LRS was less severe. Copyright © 2017. Published by Elsevier Ltd.

  6. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    OpenAIRE

    Nauth, A. (Aaron); Creek, A.T. (Aaron T.); Zellar, A. (Abby); Lawendy, A.-R. (Abdel-Rahman); Dowrick, A. (Adam); Gupta, A. (Ajay); Dadi, A. (Akhil); Kampen, A.; Yee, A. (Albert); Vries, Alexander; de Mol van Otterloo, A. (Alexander); Garibaldi, A. (Alisha); Liew, A. (Allen); McIntyre, A.W. (Allison W.); Prasad, A.S. (Amal Shankar)

    2017-01-01

    textabstractBackground Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a...

  7. The efficacy of poly-d,l-lactic acid- and hyaluronic acid-coated bone substitutes on implant fixation in sheep

    Directory of Open Access Journals (Sweden)

    Christina M. Andreasen

    2017-01-01

    Conclusion: This study demonstrates that HA/βTCP granules coated with PDLLA and HyA have similar bone ingrowth and implant fixation as those with allograft, and with mechanical properties resembling those of allograft in advance, they may be considered as alternative substitute materials for bone formation in sheep.

  8. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Qing-Hua, E-mail: ddqinghua-tian@163.com; He, Cheng-Jian, E-mail: tianhechengjian@163.com; Wu, Chun-Gen, E-mail: 649514608@qq.com; Li, Yong-Dong, E-mail: tianliyongdong@163.com; Gu, Yi-Feng, E-mail: tianyifenggu@163.com; Wang, Tao, E-mail: tianandwangtao@163.com; Xiao, Quan-Ping, E-mail: tianxiaoquanping@163.com; Li, Ming-Hua, E-mail: tianminghuali@163.com [Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Department of Diagnostic and Interventional Radiology (China)

    2016-01-15

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.

  9. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    International Nuclear Information System (INIS)

    Tian, Qing-Hua; He, Cheng-Jian; Wu, Chun-Gen; Li, Yong-Dong; Gu, Yi-Feng; Wang, Tao; Xiao, Quan-Ping; Li, Ming-Hua

    2016-01-01

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor

  10. Endochondral fracture healing with external fixation in the Sost knockout mouse results in earlier fibrocartilage callus removal and increased bone volume fraction and strength.

    Science.gov (United States)

    Morse, A; Yu, N Y C; Peacock, L; Mikulec, K; Kramer, I; Kneissel, M; McDonald, M M; Little, D G

    2015-02-01

    Sclerostin deficiency, via genetic knockout or anti-Sclerostin antibody treatment, has been shown to cause increased bone volume, density and strength of calluses following endochondral bone healing. However, there is limited data on the effect of Sclerostin deficiency on the formative early stage of fibrocartilage (non-bony tissue) formation and removal. In this study we extensively investigate the early fibrocartilage callus. Closed tibial fractures were performed on Sost(-/-) mice and age-matched wild type (C57Bl/6J) controls and assessed at multiple early time points (7, 10 and 14days), as well as at 28days post-fracture after bony union. External fixation was utilized, avoiding internal pinning and minimizing differences in stability stiffness, a variable that has confounded previous research in this area. Normal endochondral ossification progressed in wild type and Sost(-/-) mice with equivalent volumes of fibrocartilage formed at early day 7 and day 10 time points, and bony union in both genotypes by day 28. There were no significant differences in rate of bony union; however there were significant increases in fibrocartilage removal from the Sost(-/-) fracture calluses at day 14 suggesting earlier progression of endochondral healing. Earlier bone formation was seen in Sost(-/-) calluses over wild type with greater bone volume at day 10 (221%, p<0.01). The resultant Sost(-/-) united bony calluses at day 28 had increased bone volume fraction compared to wild type calluses (24%, p<0.05), and the strength of the fractured Sost(-/-) tibiae was greater than that that of wild type fractured tibiae. In summary, bony union was not altered by Sclerostin deficiency in externally-fixed closed tibial fractures, but fibrocartilage removal was enhanced and the resultant united bony calluses had increased bone fraction and increased strength. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  11. Bone suture anchor fixation in the lower extremity: a review of insertion principles and a comparative biomechanical evaluation.

    Science.gov (United States)

    Scranton, Pierce E; Lawhon, S Michael; McDermott, John E

    2005-07-01

    Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

  12. Internal Fixation of Complicated Acetabular Fractures Directed by Preoperative Surgery with 3D Printing Models.

    Science.gov (United States)

    Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng

    2017-05-01

    The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  13. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    Science.gov (United States)

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation

  14. Intramedullary screw fixation with bone autografting to treat proximal fifth metatarsal metaphyseal-diaphyseal fracture in athletes: a case series

    Directory of Open Access Journals (Sweden)

    Tsukada Sachiyuki

    2012-07-01

    Full Text Available Abstract Background Delayed unions or refractures are not rare following surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fractures. Intramedullary screw fixation with bone autografting has the potential to resolve the issue. The purpose of this study was to evaluate the result of the procedure. Methods The authors retrospectively reviewed 15 athletes who underwent surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fracture. Surgery involved intramedullary cannulated cancellous screw fixation after curettage of the fracture site, followed by bone autografting. Postoperatively, patients remain non weight-bearing in a splint or cast for two weeks and without immobilization for an additional two weeks. Full weight-bearing was allowed six weeks postoperatively. Running was permitted after radiographic bone union, and return-to-play was approved after gradually increasing the intensity. Results All patients returned to their previous level of athletic competition. Mean times to bone union, initiation of running, and return-to-play were 8.4, 8.8, and 12.1 weeks, respectively. Although no delayed unions or refractures was observed, distal diaphyseal stress fractures at the distal tip of the screw occurred in two patients and a thermal necrosis of skin occurred in one patient. Conclusions There were no delayed unions or refractures among patients after carrying out a procedure in which bone grafts were routinely performed, combined with adequate periods of immobilization and non weight-bearing. These findings suggest that this procedure may be useful option for athletes to assuring return to competition level.

  15. A feasibility study for in vitro evaluation of fixation between prosthesis and bone with bone marrow-derived mesenchymal stem cells.

    Science.gov (United States)

    Morita, Yusuke; Yamasaki, Kenichi; Hattori, Koji

    2010-10-01

    It is difficult to quantitatively evaluate adhesive strength between an implant and the neighboring bone using animal experiments, because the degree of fixation of an implant depends on differences between individuals and the clearance between the material and the bone resulting from surgical technique. A system was designed in which rat bone marrow cells were used to quantitatively evaluate the adhesion between titanium alloy plates and bone plates in vitro. Three kinds of surface treatment were used: a sand-blasted surface, a titanium-sprayed surface and a titanium-sprayed surface coated with hydroxyapatite. Bone marrow cells obtained from rat femora were seeded on the titanium alloy plates, and the cells were cultured between the titanium alloy plates and the bone plates sliced from porcine ilium for 2 weeks. After cultivation, adhesive strength was measured using a tensile test, after which DNA amount and Alkaline phosphatase activity were measured. The seeded cells accelerated adhesion of the titanium alloy plate to the bone plate. Adhesive strength of the titanium-sprayed surface was lower than that of the sand-blasted surface because of lower initial contact area, although there was no difference in Alkaline phosphatase activity between two surface treatments. A hydroxyapatite coating enhanced adhesive strength between the titanium alloy palate and the bone plate, as well as enhancing osteogenic differentiation of bone marrow cells. It is believed that this novel experimental method can be used to simultaneously evaluate the osteogenic differentiation and the adhesive strength of an implant during in vitro cultivation. 2010 Elsevier Ltd. All rights reserved.

  16. The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants

    DEFF Research Database (Denmark)

    Søballe, Kjeld; Mouzin, Olivier R G; Kidder, Louis A

    2003-01-01

    We used our established experimental model of revision joint replacement to examine the roles of hydroxyapatite coating and bone graft in improving the fixation of revision implants. The revision protocol uses the Søballe micromotion device in a preliminary 8-week period of implant instability...... a titanium alloy (Ti) or a hydroxyapatite (HA) 6.0 mm plasma-sprayed implant, in the presence or absence of allograft packed into the initial 0.75 mm peri-implant gap. The contralateral limb is subjected to primary surgery with the same implant configuration, and serves as control. 8 implants were included...

  17. Interpretation of Post-operative Distal Humerus Radiographs After Internal Fixation: Prediction of Later Loss of Fixation

    NARCIS (Netherlands)

    Claessen, F.M.; Stoop, N.; Doornberg, J.N.; Guitton, T.G.; Bekerom, M.P. van den; Ring, D.; Biert, J.; et al.,

    2016-01-01

    PURPOSE: Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after

  18. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX.

    Science.gov (United States)

    Reichel, Lee M; MacCormick, Lauren M; Dugarte, Anthony J; Rizkala, Amir R; Graves, Sara C; Cole, Peter A

    2018-02-01

    Anterior external fixation for pelvic ring fractures has shown to effectively improve stability and reduce mortality. However, these fixators can be associated with substantial morbidity such as pin tract infection, premature loss of fixation, and decreased quality of life in patients. Recently, two new methods of subcutaneous anterior pelvic internal fixation have been developed; the INFIX and the Pelvic Bridge. These methods have the purported advantages of lower wound complications, less surgical site pain, and improved quality of life. We sought to investigate the measured distances to critical anatomic structures, as well as the qualitative and topographic differences notable during implantation of both devices in the same cadaveric specimen. The Pelvic Bridge and INFIX were implanted in eleven fresh cadavers. Distances were then measured to: the superficial inguinal ring, round ligament, spermatic cord, lateral femoral cutaneous nerve (LFCN), femoral nerve, femoral artery, and femoral vein. Observations regarding implantation and topography were also recorded. The INFIX had greater measured distances from all structures except for the LFCN, in which its proximity placed this structure at risk. Neither device appears to put other critical structures at risk in the supine position. Significant implantation and topographic differences exist between the devices. The INFIX application lacked "safety margins" concerning the LFCN in 10/11 (90.9%) specimens, while Pelvic Bridge placement lacked "safety margins" with regard to the right superficial ring (1/11, 9%) and the right spermatic cord (1/11, 9%). Both the Pelvic Bridge and INFIX lie at safe distances from most critical pelvic structures in the supine position, though INFIX application places the LFCN at risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures.

    Science.gov (United States)

    Miramini, Saeed; Zhang, Lihai; Richardson, Martin; Mendis, Priyan; Ebeling, Peter R

    2016-10-01

    Mechano-regulation plays a crucial role in bone healing and involves complex cellular events. In this study, we investigate the change of mechanical microenvironment of stem cells within early fracture callus as a result of the change of fracture obliquity, gap size and fixation configuration using mechanical testing in conjunction with computational modelling. The research outcomes show that angle of obliquity (θ) has significant effects on interfragmentary movement (IFM) which influences mechanical microenvironment of the callus cells. Axial IFM at near cortex of fracture decreases with θ, while shear IFM significantly increases with θ. While a large θ can increase shear IFM by four-fold compared to transverse fracture, it also result in the tension-stress effect at near cortex of fracture callus. In addition, mechanical stimuli for cell differentiation within the callus are found to be strongly negatively correlated to angle of obliquity and gap size. It is also shown that a relatively flexible fixation could enhance callus formation in presence of a large gap but could lead to excessive callus strain and interstitial fluid flow when a small transverse fracture gap is present. In conclusion, there appears to be an optimal fixation configuration for a given angle of obliquity and gap size. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Management of complications of open reduction and internal fixation of ankle fractures.

    Science.gov (United States)

    Ng, Alan; Barnes, Esther S

    2009-01-01

    The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.

  1. Assessment of bone mineral content in the internal bone volume

    International Nuclear Information System (INIS)

    Hoeiseth, A.; Alho, A.; Husby, T.; Ullevaal Sykehus, Oslo

    1991-01-01

    A method for assessing values related to bone density and mass is described. Mean attenuation and pixel area are measured in pixels selected on the basis of CT units. The method is to a large extent computerized and not dependent on manual positioning or outlining of a region of interest. Because it is not dependent on a comparatively large volume of homogeneous bone it can be used to make assessments even in very heterogeneous bones including cortical bone. The method is adaptable for measurement in all parts of the skeleton and values related to both bone density (DRV) and bone mass (MRV) are derived. The measurements in the femoral condyles were shown to have a precision of approximately 0.25 to 0.30 Z-score units (standard deviation of the measurements expressed in Z-score units). The agreement between chemically analyzed calcium density (weight of calcium per volume) and DRV was little less than 0.50 Z-scores and 0.30 Z-scores for the chemically determined calcium mass and the MRV. The agreement with mechanical bone strength was 0.78 Z-scores for DRV and 0.64 for the MRV. Altering scan parameters or measuring approaches gave systematic differences in the measurements. There were, however, good linear correlations between the measurements which show that these different measuring approaches essentially gave identical measurements. (orig.)

  2. Outcome of nonunion fractures in dogs treated with fixation, compression resistant matrix, and recombinant human bone morphogenetic protein-2.

    Science.gov (United States)

    Massie, Anna M; Kapatkin, Amy S; Fuller, Mark C; Verstraete, Frank J M; Arzi, Boaz

    2017-03-20

    To report the use of compression resistant matrix (CRM) infused with recombinant human bone morphogenetic protein (rhBMP-2) prospectively in the healing of nonunion long-bone fractures in dogs. A longitudinal cohort of dogs that were presented with nonunion fractures were classified and treated with CRM soaked with rhBMP-2 and fracture fixation. They were followed with serial radiographs and evaluated for healing times and complications according to the time frame and definitions previously established for orthopaedic clinical cases. Eleven nonunion fractures in nine dogs were included. Median healing time was 10 weeks (range: 7-20 weeks). Major perioperative complications due to bandage morbidity were encountered in two of 11 limbs and resolved. All other complications were minor. They occurred perioperatively in eight of 11 limbs. Minor follow-up complications included short-term in one of two limbs, mid-term in one of three, and long-term in four of five limbs. Nine limbs returned to full function and two limbs returned to acceptable function at the last follow-up. Nonunion fractures given a poor prognosis via standard-of-care treatment were successfully repaired using CRM with rhBMP-2 accompanying fixation. These dogs, previously at high risk of failure, returned to full or acceptable function.

  3. The quality of life after a femoral neck fracture in elderly patients: a comparative study between internal fixation and arthroplasties

    Directory of Open Access Journals (Sweden)

    Dennis Sansanovicz

    2017-01-01

    Full Text Available Introduction: The femoral neck fracture is a frequent pathology in the elderly population, with about of 100,000 cases per year in Brazil. The surgical treatment by internal fixation or arthroplastic hip replacement is advocated today. The non-surgical treatment is reserved for cases of exception. Objective: To compare the quality of patient postoperative life treated for femoral neck fracture by two different techniques: hip arthroplasty and internal fixation. Methods: Through the SF-36 questionnaire, we study the quality of life of 60 patients with more than 65 years, treated between 2004 and 2012 in our service. Half of the patients was submitted to internal fixation and the other half to the arthroplastic replacement. Results: Higher averages in the large majority of the parameters of the questionnaire were obtained by the group which was carried out by internal fixation, but without statistical significance in most of these differences. Some international reports indicate that patients who have suffered a fracture of the femoral neck and were treated with internal fixation may recover the quality of life they had before the fracture. Paradoxically, there is a growing trend among orthopedic surgeons to perform a hip replacement surgery in these cases. Conclusion: Further studies are needed to define which is the best surgical treatment option.

  4. Acceleration and holographic studies on different types of dynamization of external fixators of the bones

    Science.gov (United States)

    Podbielska, Halina; Kasprzak, Henryk T.; Voloshin, Arkady S.; Pennig, Dietmar; von Bally, Gert

    1992-08-01

    The unilateral axially dynamic fixator (Orthofix) was mounted on a sheep tibial shaft. Three fixation modes: static, dynamic controlled, and dynamic free were examined by means of double exposure holographic interferometry. Simultaneously, the acceleration was measured by an accelerometer and displayed on the monitor together with loading characteristics. The first exposure was made before the acting force was applied to the tibia plateau. The second one after the moment when the acceleration wave started to propagate through the specimen. We stated that in the case of dynamization less torsion occurs at the fracture site. So far, we have not been able to determine any correlation between results of holographic and accelerometric measurements.

  5. The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

    Directory of Open Access Journals (Sweden)

    Kaykhosro Mardanpour

    2011-07-01

    Full Text Available Background:Unstable Pelvic fracture,a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This study was performed to evaluate the functional and radiological results of treatment of pelvic ring fractures by open reduction, internal fixation. Methods: Thirty eight patients with unstable pelvic fractures, treated from 2002 to2008 were retrospectively reviewed. The mean age of patients’ was 37 years old (range 20 to 67. Twenty six patients were men and 12 women. The most common cause was a road traffic accident (N=37, 97%. There were 11 type-C and 27 type-B fractures according to Tile’s classification. Thirty six patients sustained additional injuries. The most prevalent additional injuries were lower extremity fractures. Open reduction, internal fixation as a definite management was applied for all patients. Quality of reduction was graded according to the grades proposed by Matta and Majeed’s score was used to assess the clinical outcome. The mean period of follow-up was 25 months (ranged from 6 to 109 months. About 81.6% of patients had either good or excellent radiological reduction. Results: The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients. There were 4 postoperative infections. No sexual function problem was reported. Nerve deficits recovered completely in 2 and partially in 3 of 11 patients with preoperative neurologic deficiency. There was no significant relation between functional outcome and the site of fracture Conclusion: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization that must be carried out as soon as the general ndition of the patient permits, and

  6. Fracture healing using degradable magnesium fixation plates and screws.

    Science.gov (United States)

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Primary fixation and delayed nailing of long bone fractures in severe trauma

    DEFF Research Database (Denmark)

    Friedl, H.P.; Stoker, R.; Czermak, B.

    1996-01-01

    skeletal conditions (particularly of the lower extremities) impede optimal intensive care of these patients. Therefore in a polytrauma setup, primary operative stabilization of the femur is mandatory and generally accepted, whereas the optimal fixation procedure is still a source of controversies...

  8. A comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations.

    NARCIS (Netherlands)

    Tomaszewski, P.K.; Verdonschot, N.J.J.; Bulstra, S.K.; Verkerke, G.J.

    2010-01-01

    An alternative solution to conventional stump-socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Goteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lubeck,

  9. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations

    NARCIS (Netherlands)

    Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.; Verkerke, G. J.

    An alternative solution to conventional stump-socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Goteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lubeck,

  10. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations.

    NARCIS (Netherlands)

    Tomaszewski, P.K.; Verdonschot, Nicolaas Jacobus Joseph; Bulstra, S.K.; Verkerke, Gijsbertus Jacob

    2010-01-01

    An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck,

  11. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  12. A new internal fixation technique for fractures of the proximal humerus--the Bilboquet device: a report on 26 cases.

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Jos, E; Touzard, R C

    2000-01-01

    We describe a novel internal fixation device and report on 26 patients (mean age, 70 years) whose proximal humeral fractures were managed with this technique. The 2-part titanium implant consists of a circular staple impacted into the humeral head cancellous bone and a spigoted diaphyseal stem that inserts into the staple "cup." Of the 26 cases reviewed, 16 had 3-part fractures and 10 had 4-part fractures. Mean follow-up was 25.9 months. In the 16 3-part fractures, the mean active forward elevation was 114 degrees and the results were as follows: excellent, 7; good, 5; fair, 3; poor, 1. In the 10 4-part fracture patients, the mean active forward elevation was 101 degrees and the results were as follows: excellent, 2; good, 4; fair, 3; poor, 1. There were 5 cases of avascular necrosis and 1 case of tuberosity nonunion. Only 2 cases needed conversion to hemiarthroplasty. The new technique should simplify the surgery of these fractures and reduce the need for arthroplasty.

  13. Skeletal stability in orthognathic surgery: evaluation of methods of rigid internal fixation after counterclockwise rotation in patients with class II deformities.

    Science.gov (United States)

    Rocha, Vanessa Álvares de Castro; Neto, Antonio Irineu Trindade; Rebello, Iêda Margarida Crusoé Rocha; de Souza, Gustavo Mota Mascarenhas; Esteves, Lucas Senhorinho; dos Santos, Jean Nunes; Zanetta-Barbosa, Darceny; do Prado, Célio Jesus

    2015-10-01

    Our aim was to assess the influence of internal fixation in skeletal stability on patients who had had counterclockwise rotation of the maxillomandibular complex and mandibular advancement procedures. We studied 60 records of 20 patients (14 female, 6 male), mean (range) age at operation 29 (16-50) years. The mean (range) postoperative follow-up was 15 (8-24) months. Sixty standard lateral cephalometric radiographs were randomly traced and digitised by one senior radiologist to estimate surgical and postoperative changes. Patients were divided into two groups, the first group (n=10) of which had fixation with only 2.0 system plates (2 plates with monocortical screws alone) and the second (n=10) of which had hybrid fixation (1 plate with monocortical screws and 2 or 3 bicortical bone screws). During operation the change in the mean occlusal plane with counterclockwise rotation was 9.4° (range -17.3 to -2.5mm). The maxilla moved forward and upward. All the anterior mandibular measurements had advanced horizontally, the mean (range) being 17 (6.4 to 9.9) mm for the pogonion, and 17.6 (6.0 to 30.7) mm for the menton. At the longest follow-up period, there were significant long-term changes, but these were clinically acceptable (stability or in the magnitude of the advancement and stability. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Surgical site infection in orthopedic implants and its common bacteria with their sensitivities to antibiotics, in open reduction internal fixation

    International Nuclear Information System (INIS)

    Shah, M.Q.; Zardad, M.S.; Khan, A.; Ahmed, S.; Awan, A. S.; Mohammad, T.

    2017-01-01

    Surgical site infection in orthopaedic implants is a major problem, causing long hospital stay, cost to the patient and is a burden on health care facilities. It increases rate of non-union, osteomyelitis, implant failure, sepsis, multiorgan dysfunction and even death. Surgical site infection is defined as pain, erythema, swelling and discharge from wound site. Surgical site infection in orthopaedic implants is more challenging to the treating orthopaedic surgeon as the causative organism is protected by a biofilm over the implant's surface. Antibiotics cannot cross this film to reach the bacteria's, causing infection. Method: This descriptive case series study includes 132 patients of both genders with ages between 13 years to 60 years conducted at Orthopaedic Unit, Ayub Medical College, Abbottabad from 1st October 2015 to 31st March 2016. Patients with close fractures of long bones were included in the study to determine the frequency of surgical site infection in orthopaedic implants and the type of bacteria involved and their sensitivity to various antibiotics. All implants were of stainless steel. The implants used were Dynamic hip screws, Dynamic compression screws, plates, k-wires, Interlocking nails, SIGN nails, Austin Moore prosthesis and tension band wires. Pre-op and post-op antibiotics used were combination of Sulbactum and Cefoperazone which was given 1 hour before surgery and continued for 72 hours after surgery. Patients were followed up to 4 weeks. Pus was taken on culture stick, from those who developed infection. Results were entered in the pro forma. Results: A total of 132 patients of long bone fractures, who were treated with open reduction and internal fixation, were studied. Only 7 patients developed infection. Staphylococcus Aureus was isolated from all 7 patients. Staphylococcus aureus was sensitive to Linezolid, Fusidic Acid, and vancomycin. Cotrimoxazole, tetracycline, Gentamycin and Clindamycin were partially effective. Conclusion

  15. Comprehensive comparing percutaneous endoscopic lumbar discectomy with posterior lumbar internal fixation for treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis

    Science.gov (United States)

    Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong

    2017-01-01

    Abstract The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery. In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared. The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively. PELD operation was superior in terms of operation time, bleeding volume, recovery period

  16. Comprehensive comparing percutaneous endoscopic lumbar discectomy with posterior lumbar internal fixation for treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis: A retrospective case-control study.

    Science.gov (United States)

    Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong

    2017-07-01

    The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery.In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared.The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively.PELD operation was superior in terms of operation time, bleeding volume, recovery period, and financial

  17. Monitoring of Postoperative Bone Healing Using Smart Trauma-Fixation Device With Integrated Self-Powered Piezo-Floating-Gate Sensors.

    Science.gov (United States)

    Borchani, Wassim; Aono, Kenji; Lajnef, Nizar; Chakrabartty, Shantanu

    2016-07-01

    Achieving better surgical outcomes in cases of traumatic bone fractures requires postoperative monitoring of changes in the growth and mechanical properties of the tissue and bones during the healing process. While current in-vivo imaging techniques can provide a snapshot of the extent of bone growth, it is unable to provide a history of the healing process, which is important if any corrective surgery is required. Monitoring the time evolution of in-vivo mechanical loads using existing technology is a challenge due to the need for continuous power while maintaining patient mobility and comfort. This paper investigates the feasibility of self-powered monitoring of the bone-healing process using our previously reported piezo-floating-gate (PFG) sensors. The sensors are directly integrated with a fixation device and operate by harvesting energy from microscale strain variations in the fixation structure. We show that the sensors can record and store the statistics of the strain evolution during the healing process for offline retrieval and analysis. Additionally, we present measurement results using a biomechanical phantom comprising of a femur fracture fixation plate; bone healing is emulated by inserting different materials, with gradually increasing elastic moduli, inside a fracture gap. The PFG sensor can effectively sense, compute, and record continuously evolving statistics of mechanical loading over a typical healing period of a bone, and the statistics could be used to differentiate between different bone-healing conditions. The proposed sensor presents a reliable objective technique to assess bone-healing progress and help decide on the removal time of the fixation device.

  18. Lag screw fixation of dorsal cortical stress fractures of the third metacarpal bone in 116 racehorses.

    Science.gov (United States)

    Jalim, S L; McIlwraith, C W; Goodman, N L; Anderson, G A

    2010-10-01

    The effectiveness and best method to manage dorsal cortical stress fractures is not clear. This study was performed to evaluate the success of lag screw fixation of such fractures in a population of Thoroughbred racehorses. Lag screw fixation of dorsal cortical stress fractures is an effective surgical procedure allowing racehorses to return to their preoperative level of performance. The records of 116 racehorses (103 Thoroughbreds) admitted to Equine Medical Centre, California between 1986 and 2008 were assessed. Information obtained from medical records included subject details, limb(s) affected, fracture configuration, length of screw used in repair and presence of concurrent surgical procedures performed. Racing performance was evaluated relative to these factors using Fisher's exact test and nonparametric methods with a level of significance of Phorses, 83% raced preoperatively and 83% raced post operatively, with 63% having ≥5 starts. There was no statistically significant association between age, gender, limb affected, fracture configuration or presence of concurrent surgery and likelihood of racing post operatively or of having 5 or more starts. The mean earnings per start and the performance index for the 3 races following surgery were lower compared to the 3 races prior to surgery; however, 29 and 45% of horses either improved or did not change their earnings per start and performance index, respectively. Data show that lag screw fixation is successful at restoring ability to race in horses suffering from dorsal cortical stress fractures. © 2010 EVJ Ltd.

  19. Unstable metacarpal and phalangeal fractures: treatment by internal fixation using AO mini-fragment plates and screws.

    Science.gov (United States)

    Mumtaz, Mohammad Umar; Farooq, Muneer Ahmad; Rasool, Altaf Ahmad; Kawoosa, Altaf Ahmad; Badoo, Abdul Rashid; Dhar, Shabir Ahmad

    2010-07-01

    Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can provide rigid fixation, allowing early mobilization of joints and hence good functional results while avoiding problems associated with protruding K-wires and immobilization. The advantages of such internal fixation urged us to undertake such a study in our state where such hand injuries are commonly seen. Forty patients with 42 unstable metacarpal and phalangeal fractures were treated with open reduction and internal fixation using AO mini-fragment screws and plates over a period of three years in a prospective manner. The overall results were good in 78.5% of cases, fair in 19% of cases and poor in 2.5% of cases, as judged according to the criteria of the American Society for Surgery of the Hand. This technique is a reasonable option for treating unstable metacarpal and phalangeal fractures as it provides a highly rigid fixation, which is sufficient to allow early mobilization of the adjacent joints, thus helping to achieve good functional results.

  20. Promising Effect Of Intraarticular Ropivacaine In Femoral Neck Fractures Treated With Internal Fixation (Best Poster Award)

    DEFF Research Database (Denmark)

    Bech, Rune Dueholm

    2008-01-01

     Promising Effect Of Intraarticular Ropivacaine In Femoral Neck Fractures Treated With Internal Fixation Rune Bech*, Jens Lauritsen*+,Tine Dimon*, Ole Ovesen*, Claus Emmeluth, Søren Overgaard*. *:Dept. Ortopaedic Surgery, Odense University Hospital, +:Institute of Public Health-dept. biostatistics...... underwent osteosynthesis with 2 canulated hip screws and were prescribed regular paracetamol and supplementary opioid rescue analgesia as necessary. Pilot group: 11 patients received one peroperative (30 mL=100 mg) and 6 postoperative bolus installations  (10 mL=100 mg) of open label Ropivacaine through......-74) (p=0.012).   CONCLUSION This pilot-study suggests that intraarticular application of Ropivacaine may reduce opioid requirement after osteosynthesis of femoral neck fracture. However, this is an open pilot study with few patients. We find the results promising and have initiated a double...

  1. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    Science.gov (United States)

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

  2. Biomechanical Evaluation of the MACSTL Internal Fixator for Thoracic Spinal Stabilisation

    Directory of Open Access Journals (Sweden)

    R. Veselý

    2008-01-01

    Full Text Available Unstable fractures of the thoracic spine in humans represent a serious social and economic issue. They may lead to persistent consequences and chronic disease. The anatomical and biomechanical characteristics of the thoracic spine are different from all the other spinal parts due to its higher mobility. The vertebrae of the chest area are less mobile, conferring a higher degree of rigidity to the spine. To destabilize this relatively rigid system, a considerable force is necessary. The treatment of unstable spinal fractures is solely surgical. The decompression of the spinal canal with reposition and stabilisation of the fracture is indicated urgently. This intervention is performed mostly from the posterior approach in the first phase. However, the anterior spinal column is the structure responsible for the stability of the spine. Therefore, the recent advances in spine surgery focus on this area of expertise. For this reason, we carried out a bio-mechanical study aimed at assessing the effectiveness of two surgical tactics used. The study consisted of comparative experiments performed by computer-aided device on segments of pig cadavers (n = 5. The experiment involved a comparison of segments of the thoracic spine under the following conditions: an anatomically intact segment, a spine segment with an artificially created anterior instability, and a segment with an applied internal fixator. The experiment compared the mechanical characteristics of these segments. The experiment has demonstrated that after application of the internal fixator used for stabilisation of the injured anterior spinal column at defined pre-loading of 200 N, the stability of damaged spinal segment in torsion increased twofold. It was also verified that sufficient stability can be ensured using the Modular Anterior Construct System (MACSTL implant for ventral stabilisation of thoracic spine unstable injuries. Endoscopic application of this implant represents an

  3. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Keykhosro Mardanpour

    2013-07-01

    Full Text Available BACKGROUND: This study was performed to evaluate functional and radiological results of pelvic ring fractures treatment by open reduction and internal fixation. METHOD: Thirty eight patients with unstable pelvic fractures, treated from 2002 to 2008 were retrospectively reviewed. The mean patients’ age was 37 years (range 20 to 67. Twenty six patients were men (4patients with type B and 22 patients with type C fracture and 12 women (7 patients with type B and 5 patients with type C fracture. The commonest cause was a road traffic accident (N=37, about 97%. Internal fixation was done by plaque with ilioinguinal and kocher-langenbeek approaches for anterior, posterior pelvic wall and acetabulum fracture respectively. Quality of reduction was graded according to Majeed score system. RESULTS: There were 11 type-C and 27 type-B pelvic fractures according to Tile’s classification. Thirty six patients sustained additional injuries. the commonest additional injury was lower extremity fracture. The mean follow-up was 45.6 months (range 16 to 84 months.The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients with type B pelvic fractures and functional outcome was excellent in 46%, good in 27%, fair in 27% and poor in 0% of the patients with type C pelvic fractures. There were four postoperative infections. No sexual functional problem was reported. Neurologic problem like Lateral cutaneous nerve of thigh injury recovered completely in 2 patients and partially in 2 patients. There was no significant relation between functional outcome and the site of fracture (P greater than 0.005. CONCLUSION: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization. It must be carried out as soon as the general condition of the patient permits, and even up to two weeks

  4. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  5. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-04-01

    To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  6. Design and application of hybrid maxillomandibular fixation for facial bone fractures.

    Science.gov (United States)

    Park, Kang-Nam; Oh, Seung-Min; Lee, Chang-Youn; Kim, Jwa-Young; Yang, Byoung-Eun

    2013-01-01

    A novel maxillomandibular fixation (MMF) procedure using a skeletal anchorage screw (SAS) (in the maxilla) and an arch bar (in the mandible), which we call "hybrid maxillomandibular fixation," was explored in this study. The aims of the study were to examine the efficacy of our hybrid MMF method and to compare periodontal tissue health and occlusal rehabilitation among 3 MMF methods. In total, 112 patients who had undergone open reduction at the Department of Oral and Maxillofacial Surgery between September 2005 and December 2012 were selected for this study. The participants were assigned to one of the following groups: SAS (maxilla), SAS (mandible), SAS-arch bar, or arch bar-arch bar. Periodontal health was evaluated using the Gingival Index, and the perioperative occlusal reproducibility was evaluated using a score of 1 to 3. Statistical analysis was performed using parametric tests (Student t test or 1-way analysis of variance followed by post hoc Tukey test). In the Gingival Index comparison performed 1 month after the surgery, only the group using the arch bars and wiring was significantly different from the other groups (P fractures. In addition, it overcomes many problems presented by previous MMF methods.

  7. A STUDY OF POSTERIOR LUMBAR INTERBODY FUSION WITH LOCALLY HARVESTED SPINOLAMINECTOMY BONE GRAFT AND PEDICLE SCREW FIXATION IN SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Pardhasaradhi M

    2017-08-01

    Full Text Available BACKGROUND Posterior Lumbar Interbody Fusion (PLIF and Transforaminal Lumbar Interbody Fusion (TLIF create intervertebral fusion by means of a posterior approach. Successful results have been reported with allograft, various cages (for interbody support, autograft and recombinant human bone morphogenetic protein‐2. Interbody fusion techniques facilitate reduction and enhance fusion. Corticocancellous laminectomy bone chips alone can be used as a means of spinal fusion in patients with single level instrumented PLIF. This has got a good fusion rate. PLIF with cage gives better fusion on radiology than PLIF with iliac bone graft, but no statistical difference in the clinical outcome. Cage use precludes complications associated with iliac bone harvesting. The reported adjacent segment degeneration was 40.5% and reoperation was 8.1% after 10 years of follow up. MATERIALS AND METHODS 30 cases of spondylolisthesis who attended the Orthopaedic Outpatient Department of Andhra Medical College, Visakhapatnam, from 2014 to 2016 were taken up for study. All the cases were examined clinically and confirmed radiologically. The patient’s age, sex, symptoms and duration were noted and were examined clinically for the status of the spine. Straight leg raising test was done and neurological examination of the lower limbs performed. All the patients were subjected to the radiological examination of the lumbosacral spine by taking anteroposterior, lateral (flexion and extension views, oblique views to demonstrate spondylolysis and spondylolisthesis. MRI and x-rays studies were done in all the cases to facilitate evaluation of the root compression disk changes and spinal cord changes. RESULTS In our study, we followed all the 30 patients after the surgery following procedure of removal of loose lamina, spinous process and fibrocartilaginous mass, PLIF with only the laminectomy bone mass and CD screw system fixation up to 2 years. 12 patients (40% had excellent

  8. Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Dennis; Toendevold, Erik

    2015-01-01

    was evaluated on reconstructed coronal and sagittal images of the acetabulum. Results - The fracture severity and patient characteristics were similar in the 2 groups. In the 3D group, 46 of 72 patients (0.6) had a perfect result after open reduction and internal fixation, and in the control group, 17 of 42 (0...

  9. Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Schmal, Hagen; Hauschild, Oliver

    2010-01-01

    PURPOSE: Our purpose was to evaluate the 3-year clinical results of patients with medial-compartment osteoarthritis of the knee and varus malalignment who underwent open-wedge high tibial osteotomy (HTO) with an internal plate fixator (TomoFix; Synthes, Solothurn, Switzerland). Clinical results a...

  10. Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus

    NARCIS (Netherlands)

    Wijgman, A. J.; Roolker, W.; Patt, T. W.; Raaymakers, E. L. F. B.; Marti, R. K.

    2002-01-01

    BACKGROUND: Controversy persists concerning the preferred treatment of displaced fractures of the proximal part of the humerus. The present study was undertaken to evaluate the results of open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus and

  11. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].

    Science.gov (United States)

    Liu, Jinliang; Li, Keyao; He, Jianning

    2011-01-01

    To study the indications, methods, and therapeutic effect of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. Between March 2007 and September 2009, 40 patients with multiple rib fractures received internal fixation with absorbable rib-connecting-pins, including 8 one-side flail chest and 1 two-side flail chest. There were 32 males and 8 females with an average age of 39.8 years (range, 25-72 years). The injury was caused by traffic accident in 32 cases, falling from height in 6 cases, and blunt hitting in 2 cases. Preoperatively, imaging data of the chest X-ray or spiral CT three-dimensional (3D) examination showed that all patients had multiple ribs fractures and displacement. The number of fractured ribs was 4-10 (median, 6), and the fracture location ranged from the 2nd to the 10th ribs. Of them, 28 cases were accompanied by hemathorax, pneumothorax or hemopneumothorax; 5 cases by thoracic organ injury; and 10 cases by other part trauma. The time from injury to hospitalization was less than 1 day in 26 cases, 1-3 days in 12 cases, and 3-6 days in 2 cases, and the time from hospitalization to operation was 3 hours to 3 days (mean, 1.2 days). The median fixation rib number was 5 (range, 3-8). The mean operative time, the time in bed, and hospitalization days were 32 minutes (range, 15-50 minutes), 4.5 days (range, 2-7 days), and 11.2 days (range, 5-18 days), respectively. All incisions healed by first intention. No pulmonary infection, pulmonary atelectasis, intrathoracic infection or other complications occurred. All cases were followed up 6-12 months (mean, 8 months). PaO2 [(86.6 +/- 2.2) mmHg (1 mm Hg = 0.133 kPa)] and SpO2 (97.2% +/- 0.6%) at 2 hours after operation were obviously improved when compared with preoperative ones (PaO2 (53.6 + 4.7) mm Hg and SpO2 (86.2% + 1.8%)], showing significant differences (t = 2.971, P = 0.005; t = 2.426, P = 0.020). The chest X-ray films or spiral CT 3D indicated that fracture of rib

  12. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures.

    Science.gov (United States)

    Tang, Xin; Liu, Lei; Tu, Chong-qi; Li, Jian; Li, Qi; Pei, Fu-xing

    2014-07-01

    The timing of surgery for osteosynthesis of type C pilon (AO/OTA) fractures remains controversial. The aim of this study was to determine the outcome of early and delayed open reduction and internal fixation (ORIF) for treating closed type C pilon fractures. Forty-six patients with closed type C pilon fractures matched according to age, gender, soft tissue conditions, and fracture pattern were divided into group A (early group: underwent surgery within 36 hours of the injury) or group B (delayed group: underwent surgery 10 days to 3 weeks postinjury after the soft tissue swelling subsided). In the delayed group, 9 patients were treated first by temporary external fixation. All the closed fractures were managed by ORIF with locking plates. At follow-up, the clinical and radiographic results were retrospectively analyzed. The mean follow-up time was 25.8 months (range, 14 to 48 months) in group A and 26.0 months (range, 15 to 44 months) in group B. There was no significant difference (P > .05) between the 2 groups regarding the rate of soft tissue complication, the rate of fracture union, and the final functional score. The patients in group A had a significantly shorter mean time to fracture union (21.5 ± 4.0 weeks vs 23.3 ± 3.7 weeks, P fractures can be safe and effective, with similar rates of wound complication, fracture union, and final good functional recovery but shorter operative time, union time, and hospital stay. These results favorably compare with delayed ORIF treatment. Level III, retrospective comparative study. © The Author(s) 2014.

  13. Modifying bone scaffold architecture in vivo with permanent magnets to facilitate fixation of magnetic scaffolds.

    Science.gov (United States)

    Panseri, S; Russo, A; Sartori, M; Giavaresi, G; Sandri, M; Fini, M; Maltarello, M C; Shelyakova, T; Ortolani, A; Visani, A; Dediu, V; Tampieri, A; Marcacci, M

    2013-10-01

    The fundamental elements of tissue regeneration are cells, biochemical signals and the three-dimensional microenvironment. In the described approach, biomineralized-collagen biomaterial functions as a scaffold and provides biochemical stimuli for tissue regeneration. In addition superparamagnetic nanoparticles were used to magnetize the biomaterials with direct nucleation on collagen fibres or impregnation techniques. Minimally invasive surgery was performed on 12 rabbits to implant cylindrical NdFeB magnets in close proximity to magnetic scaffolds within the lateral condyles of the distal femoral epiphyses. Under this static magnetic field we demonstrated, for the first time in vivo, that the ability to modify the scaffold architecture could influence tissue regeneration obtaining a well-ordered tissue. Moreover, the association between NdFeB magnet and magnetic scaffolds represents a potential technique to ensure scaffold fixation avoiding micromotion at the tissue/biomaterial interface. © 2013.

  14. A paradigm for the development and evaluation of novel implant topologies for bone fixation: in vivo evaluation.

    Science.gov (United States)

    Long, Jason P; Hollister, Scott J; Goldstein, Steven A

    2012-10-11

    While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopedic implants and then fabricated selected designs from titanium (Ti)-alloy with selective laser sintering (SLS) technology. In the present study, we examined how implant architecture and mechanical stimulation influence osseointegration within an in vivo environment. To do this, we evaluated three implant designs (two optimized and one non-optimized) using a unique in vivo model that applied cyclic, tension/compression loads to the implants. Eighteen (six per implant design) adult male canines had implants surgically placed in their proximal, tibial metaphyses. Experimental duration was 12 weeks; daily loading (peak load of ±22 N for 1000 cycles) was applied to one of each animal's bilateral implants for the latter six weeks. Following harvest, osseointegration was assessed by non-destructive mechanical testing, micro-computed tomography (microCT) and back-scatter scanning electron microscopy (SEM). Data revealed that implant loading enhanced osseointegration by significantly increasing construct stiffness, peri-implant trabecular morphology, and percentages of interface connectivity and bone ingrowth. While this experiment did not demonstrate a clear advantage associated with the optimized implant designs, osseointegration was found to be significantly influenced by aspects of implant architecture. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Ununited fracture neck of femur treated with closed reduction and internal fixation with cancellous screw and fibular strut graft

    Directory of Open Access Journals (Sweden)

    Singh Daria

    2006-01-01

    Full Text Available Background: Ununited fracture neck of femur in young adults has been tackled in various ways. Methods: Twenty five patients of ununited fracture neck of femur in age group 21-55 years were treated by closed reduction, cancellous screw fixation and fibular strut graft and followed up for 2-6 years. Time gap between injury and operation was 6 weeks to 58 weeks. Five cases were previously fixed with various fixation devices. Results: Osseous union was achieved in 24 cases with average time of 18.16 weeks. Main complication encountered in follow-up was avascular necrosis of femoral head, others were joint stiffness and shortening. Functional end results were good to excellent in 24 cases. Conclusion: Closed reduction with internal fixation by cancellous screw and fibular strut grafting is easy and useful procedure.

  16. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  17. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    Science.gov (United States)

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without

  18. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].

    Science.gov (United States)

    Zeman, P; Zeman, J; Matejka, J; Koudela, K

    2008-12-01

    To report on the surgical treatment of intra-articular calcaneal fractures by open reduction and internal fixation with a calcaneal locking compression plate (LCP) from an extended lateral approach, and to retrospectively analyze the mid-term results in a group of patients treated by this technique. In the period from August 2005 till March 2007, a total of 49 patients with 61 calcaneal fractures were treated. Of these, 11 (18 %) were treated conservatively. Reduction combined with Kirschner-wire fixation was used in four fractures (6.6 %). Open reduction with internal calcaneal LCP fixation (ORIF- calcaneal LCP) from an extended lateral approach was carried out to treat 46 fractures (75.4 %) in 38 patients. The group evaluated here comprised 29 patients with 33 calcaneal fractures treated by ORIF-calcaneal LCP at a follow-up longer than 6 months. The fractures were classified on the basis of computer tomography (CT) findings as Sanders types I to IV. The group had two woman (6.9 %) and 27 men (93.1 %) with an average age of 34.2 years (range, 19-55 years). In 11 fractures (33.3 %), the primary treatment included filling a central cancellous bone defect area. Calcium phosphate bone substitute material (resorbable ChronOS) was used in nine cases (27.3 %), a self-solidifying hydroxyapatite implant was injected in two (6.1 %) cases (X3 Wright and Norian SRS, respectively), and a bone allograft was implanted in one case (3 %). Indicated for surgery were patients with an intra-articular calcaneal fracture, Sanders type II or type III, with articular surface displacement by more than 1 mm. Contraindications included age over sixty years, poor cooperation, smoking habits, peripheral vascular disease or skin infection. Surgery was performed only after oedema had resolved. The aim of our treatment was to achieve anatomical reconstruction of all articular surfaces, to restore the height, length, width and axis of the heel bone, to carry out primary stable osteosynthesis, and

  19. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  20. Modifications to a 3D-printed temporal bone model for augmented stapes fixation surgery teaching.

    Science.gov (United States)

    Nguyen, Yann; Mamelle, Elisabeth; De Seta, Daniele; Sterkers, Olivier; Bernardeschi, Daniele; Torres, Renato

    2017-07-01

    Functional outcomes and complications in otosclerosis surgery are governed by the surgeon's experience. Thus, teaching the procedure to residents to guide them through the learning process as quickly as possible is challenging. Artificial 3D-printed temporal bones are replacing cadaver specimens in many institutions to learn mastoidectomy, but these are not suitable for middle ear surgery training. The goal of this work was to adapt such an artificial temporal bone to aid the teaching of otosclerosis surgery and to evaluate this tool. We have modified a commercially available 3D-printed temporal bone by replacing the incus and stapes of the model with in-house 3D-printed ossicles. The incus could be attached to a 6-axis force sensor. The stapes footplate was fenestrated and attached to a 1-axis force sensor. Six junior surgeons (residents) and seven senior surgeons (fellows or consultants) were enrolled to perform piston prosthesis placement and crimping as performed during otosclerosis surgery. The time required to perform the tasks and the forces applied to the incus and stapes were collected and analyzed. No statistically significant differences were observed between the junior and senior groups for time taken to perform the tasks and the forces applied to the incus during crimping and placement of the prosthesis. However, significantly lower forces were applied to the stapes by the senior surgeons in comparison with the junior surgeons during prosthesis placement (junior vs senior group, 328 ± 202.9 vs 80 ± 99.6 mN, p = 0.008) and during prosthesis crimping (junior vs senior group, 565 ± 233 vs 66 ± 48.6 mN, p = 0.02). We have described a new teaching tool for otosclerosis surgery based on the modification of a 3D-printed temporal bone to implement force sensors on the incus and stapes. This tool could be used as a training tool to help the residents to self-evaluate their progress with recording of objective measurements.

  1. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    Science.gov (United States)

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  2. Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

    Science.gov (United States)

    Elmengaard, Brian; Baas, Joergen; Jakobsen, Thomas; Kold, Soren; Jensen, Thomas B; Bechtold, Joan E; Soballe, Kjeld

    2017-02-01

    We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 μm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. The grafted crack revision improved

  3. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.

    Science.gov (United States)

    Zhou, Yan; Perkins, Luke A; Wang, Guodong; Zhou, Dongsheng; Liang, Hong

    2015-10-15

    Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  4. Posterior Cruciate Ligament Tibial Avulsion treated with Open Reduction and Internal Fixation

    Directory of Open Access Journals (Sweden)

    Lee WXP

    2015-07-01

    Full Text Available The optimal treatment for thoracolumbar fractures (TLF without neurological deficit remains controversial. Majority of the systematic reviews and meta-analyses have evaluated open operative approaches but have yet to compare the outcomes of minimally invasive percutaneous pedicle fixation (MIPPF versus non-operative treatment. A retrospective cohort study was performed to compare clinical and radiological outcomes between MIPPF and conservative groups for TLF AO Type A1 to Type B2 during a 2-year follow-up period. Pre-operative plain and CT films were evaluated and decision made for short segment (non-fusion MIPPF. Patients who refused operation were treated conservatively with three months of body cast, brace, or corset. MIPPF group showed earlier Visual Analog Score (VAS improvement at six months post-injury (0 vs 6.0- p0.050. MIPPF as a method of internal bracing can be pursued in the treatment of TLF, with larger future cohorts and RCTs being called for to support and explore new findings.

  5. Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Chris Dillingham

    2011-01-01

    Full Text Available Purpose. To determine recovery timeline of unstable distal radius fractures treated by open reduction and internal fixation with a locking volar plate. Methods. Data was collected prospectively on a consecutive series of twenty-seven patients during routine post-operative visits at 2 and 6 weeks, and 3, 6, 12 and 24 months. Range of motion measures and grip strength for both wrists were recorded. Results. Greatest gains were made within the first 3 months after surgery. Supination and pronation returned more quickly than flexion or extension, with supination and pronation both at 92% of the uninjured wrist at 3 months. Only flexion improved significantly between 3 and 6 months. All wrist motions showed some improvement until 1 year. Grip strength returned to 94% of the uninjured wrist by 12 months. Conclusions. Range of motion improvement will be greatest between 2 weeks and 3 months, with improvement continuing until 12 months. Grip strength should return to near normal by one year. Function and pain will improve, but not return to normal by the end of 12 months. Clinical Relevance. These results provide the surgeon with information that can be shared with patients on the anticipated timeline for normal recovery of function and strength.

  6. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants

    Directory of Open Access Journals (Sweden)

    Yan Zhou

    2015-10-01

    Full Text Available Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  7. Combined fixation, intern and external, in proximal complex fractures of the tibia

    International Nuclear Information System (INIS)

    Quintero Laverde, Jaime; Lozano Ortiz, Victor Hugo; Rojas Duque, Guillermo

    2002-01-01

    Between August of 1997 and December of 2001, they were treated in the orthopedics department and traumatology of the Hospital Clinica San Rafael, 16 patients with proximal complex fractures of the tibia, using internal fixation with plate in the lateral column and an unilateral external fixer, for the medial column. It carries out a clinical and radiological pursuit with average of 27 months (minimum 4.5, maximum 40 months). In 15 patients (93,7%) it was obtained a primary consolidation and 1 case (6,2%) it presented retard in the consolidation being necessary the placement of bony implants. in 2 cases (12,5%) there was superficial infection, one in the itinerary of the nails and another in area of superficial necrosis in soft fabrics in a closed fracture. single 1 case (6,2) it presented deep infection, which, it improve with bony curettage and antibiotics. In the final radiographic evaluation, 2 cases (12,5%) they presented depression of the lateral plate; according to the functional scale of Rasmussen excellent results were obtained (27 to 30 points) in 11 cases (68,7%) and good (20 to 26 points) in 5 cases (31,2%). The radiographic results and functional global they suggest that the combination of a technique less invasive in this area criticizes, it represents a good alternative for the treatment of the proximal complex fractures of the tibia

  8. Update on open reduction and internal fixation of unstable pelvic fractures during pregnancy: case reports

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    Full Text Available ABSTRACT This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report: The study included four cases of pregnant women with unstable pelvic fractures; their outcomes were analyzed and discussed. Data were obtained from two University Hospitals. The mean age of women was 23 years; most (3/4 were primiparous, with a mean pregnancy age of 23 weeks. Two women had Malgaigne-type fractures and the other two had symphyseal disjunction associated with acetabular fractures. All fractures were treated surgically. One foetus was dead on admission to hospital. The other three developed well, along with their mothers. Good evolution was only possible with careful pre-, peri-, and postoperative care for the mother, as well as foetal assessment by a multidisciplinary team. In complex cases such as those presented in the present study, pre-, peri-, and postoperative care are mandatory, as well as the presence of a multidisciplinary team. The mother's life always takes priority in acute clinical pictures, as it offers the best chance of survival to both mother and child.

  9. [Case-control study on minimally invasive percutaneous locking compression plate internal fixation for the treatment of type II and III pilon fractures].

    Science.gov (United States)

    Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao

    2011-12-01

    To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.

  10. The treatment of scaphoid nonunion using the Ilizarov fixator without bone graft, a study of 18 cases

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko

    2011-11-01

    Full Text Available Abstract Objectives Evaluating the safety and efficacy of the Ilizarov fine-wire compression/distraction technique in the treatment of scaphoid nonunion (SNU, without the use of bone graft. Design A retrospective review of 18 consecutive patients in one centre. Patients and Methods 18 patients; 17 males; 1 female, with a mean SNU duration of 13.9 months. Patients with carpal instability, humpback deformity, carpal collapse, avascular necrosis or marked degenerative change, were excluded. Following frame application the treatment consisted of three stages: the frame was distracted 1 mm per day until radiographs showed a 2-3 mm opening at the SNU site (mean 10 days; the SNU site was then compressed for 5 days, at a rate of 1 mm per day, with the wrist in 15 degrees of flexion and 15 degrees of radial deviation; the third stage involved immobilization with the Ilizarov fixator for 6 weeks. The technique is detailed herein. Results Radiographic (CT and clinical bony union was achieved in all 18 patients after a mean of 89 days (70-130 days. Mean modified Mayo wrist scores improved from 21 to 86 at a mean follow-up of 37 months (24-72 months, with good/excellent results in 14 patients. All patients returned to their pre-injury occupations and levels of activity at a mean of 117 days. Three patients suffered superficial K-wire infections, which resolved with oral antibiotics. Conclusions In these selected patients this technique safely achieved bony union without the need to open the SNU site and without the use of bone graft.

  11. Treatment of stress fracture of the olecranon in throwing athletes with internal fixation through a small incision

    Directory of Open Access Journals (Sweden)

    Fujioka Hiroyuki

    2012-12-01

    Full Text Available Abstract The present study is a report of retrospective case series of stress fracture of the olecranon. Six patients presented posterior elbow pain in throwing in baseball and softball, but fracture was not diagnosed in radiographs. We detected stress fracture of the olecranon using computed tomographic (CT scan and treated the patient with internal fixation with a headless cannulated double threaded screw through a small skin incision. All patients returned to competitive level without elbow complaints after the operation. When throwing athletes present with unusual posterior elbow pain and no significant findings on radiographs, a CT scan examination should be performed. We recommend surgical treatment of internal fixation with a screw through a small skin incision, as a good option for stress fracture of the olecranon in order to allow early return to sports activity in competitive athletes.

  12. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome.

    Science.gov (United States)

    Gill, Simrat Pal Singh; Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-02-01

    Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian's criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives

  13. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study

    OpenAIRE

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-01

    Background Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. Methods The authors developed a new adjustable drill guide for cannulated screw guide wire insertion fo...

  14. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

    Science.gov (United States)

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-11

    Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.

  15. The impact of zoledronic acid on regenerate and native bone after consolidation and removal of the external fixator: an animal model study.

    Science.gov (United States)

    Saghieh, Said; Khoury, Nabil J; Tawil, Ayman; Masrouha, Karim Z; Musallam, Khaled M; Khalaf, Kinda; Dosh, Laura; Jaouhari, Rosemarie Reich; Birjawi, Ghina; El-Hajj-Fuleihan, Ghada

    2010-02-01

    We investigated the role of zoledronic acid on the regenerate and native bone after consolidation and removal of the external fixator in a rabbit model of distraction osteogenesis using 28 New Zealand white rabbits. The rabbits were randomly distributed into two groups. The first group received three doses of zoledronic acid (ZA) 0.1 mg/kg subcutaneously at weekly intervals while the second group received injections of sterile saline. Distraction started on day 7 at a rate of 0.8 mm/day for 12 days. At week 3 the average lengthening, regenerate density, and regenerate continuity were comparable between the two groups. At week 11 the regenerate in the treated group had a significant increase in Bone Mineral Density (BMD) and Bone Mineral Content (BMC) compared to the placebo group. On axial compression, the regenerate showed an increase in the peak load and a higher modulus of elasticity in the treated group. At 6 months, radiographs demonstrated signs of osteopenia of the proximal metaphysis in the control group, and failure of new bone formation around the pin sites in the treated group. BMC and BMD value differences between the two groups were not statistically significant. Histologically, there was persistence of more bone trabeculae in the medullary canal of the regenerate with the persistence of the pin-holes in the treated group. Mechanically, the regenerates in the treated group remain stronger in resisting the axial compression. The proximal fragment in the treated group exhibited a statistically significant decrease in the peak load, toughness and efail %. In conclusion, bisphosphonate-treated rabbits have a stronger regenerate during distraction, and directly after removal of the fixator. They do not develop disuse osteopenia in their lengthened tibia. This treatment may shorten the time in the external fixator and prevent fragility fractures in the treated extremity. However, its long-term safety has not yet been established. (c) 2009 Elsevier Inc. All

  16. Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

    Directory of Open Access Journals (Sweden)

    Khan I

    2016-07-01

    Full Text Available Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1 or transverse with mildly comminuted (AO34-C2 patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results: There were eighteen males (72% and seven females (28%. The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72% followed by road traffic accident (20% and violent quadriceps contraction (8%. Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks. Mean ROM at three months was 113.8 degree (90-130 and at final follow up this improved to 125.4 degrees (range 100-140. There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion: Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

  17. Management of extra-articular segmental defects in long bone using a titanium mesh cage as an adjunct to other methods of fixation.

    Science.gov (United States)

    Attias, N; Thabet, A M; Prabhakar, G; Dollahite, J A; Gehlert, R J; DeCoster, T A

    2018-05-01

    Aims This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect. Patients and Methods A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively. Results The mean time to follow-up was 55 months (12 to 126). Overall, 16 (94%) of the patients achieved radiological filling of their bony defect and united to the native bone ends proximally and distally, resulting in a functioning limb. Complications included device failure in two patients (12%), infection in two (12%), and wound dehiscence in one (6%). Four patients (24%) required secondary surgery, four (24%) had a residual limb-length discrepancy, and one (6%) had a residual angular limb deformity. Conclusion A titanium mesh cage is a useful adjunct in the treatment of an extra-articular segmental defect in a long bone. Cite this article: Bone Joint J 2018;100-B:646-51.

  18. A Novel Murine Model of Established Staphylococcal Bone Infection in the Presence of a Fracture Fixation Plate to Study Therapies Utilizing Antibiotic-laden Spacers after Revision Surgery

    Science.gov (United States)

    Inzana, Jason A.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.

    2014-01-01

    Mice are the small animal model of choice in biomedical research due to the low cost and availability of genetically engineered lines. However, the devices utilized in current mouse models of implant-associated bone infection have been limited to intramedullary or trans-cortical pins, which are not amenable to treatments involving extensive debridement of a full-thickness bone loss and placement of a segmental antibiotic spacer. To overcome these limitations, we developed a clinically faithful model that utilizes a locking fracture fixation plate to enable debridement of an infected segmental bone defect (full-thickness osteotomy) during a revision surgery, and investigated the therapeutic effects of placing an antibiotic-laden spacer in the segmental bone defect. To first determine the ideal time point for revision following infection, a 0.7 mm osteotomy in the femoral mid-shaft was stabilized with a radiolucent PEEK fixation plate. The defect was inoculated with bioluminescent Staphylococcus aureus, and the infection was monitored over 14 days by bioluminescent imaging (BLI). Osteolysis and reactive bone formation were assessed by X-ray and micro-computed tomography (micro-CT). The active bacterial infection peaked by 5 days post-inoculation, however the stability of the implant fixation became compromised by 10–14 days post-inoculation due to osteolysis around the screws. Thus, day 7 was defined as the ideal time point to perform the revision surgery. During the revision surgery, the infected tissue was debrided and the osteotomy was widened to 3 mm to place a poly-methyl methacrylate spacer, with or without vancomycin. Half of the groups also received systemic vancomycin for the remaining 21 days of the study. The viable bacteria remaining at the end of the study were measured using colony forming unit assays. Volumetric bone changes (osteolysis and reactive bone formation) were directly measured using micro-CT image analysis. Mice that were treated with

  19. [Analysis of tension-distraction state in the shin bones fractures in conditions of external fixation with application of apparatuses with different spatially oriented supports].

    Science.gov (United States)

    Hutsuliak, V I

    2014-09-01

    In Autodesk Inventor 11 program, using method of end-capping elements, a three- dimensional computeric modelling of biomechanical systems of two models was conducted: I - "tibia - Ilizarov's apparatus with concentric location of supports"; II - "tibia - Ilizarov's apparatus with excentric location of supports". The loading, which was applied towards distal fragment in 6 standard degrees of freedom, was modelled for studying of the fixation rigidity of tibial fragments in these systems. Determination of the loading value in various directions, in which the fragment have had shifted by 1 mm, have constituted the main task of the investigation. In a model II a rigidity of the fragments fixation, in comparison with such in a model I, is bigger by 631.43% - while applying a compression loading, by 8.35 - 31.75% - the transversal one and by 19.72% - the rotation loading. While choosing the method of transosteal osteosynthesis of the shin bones the advantage, have the apparatuses with excentric location of supports, what secures the enhanced rigidity of the fragments fixation in comparison with such in apparatuses with concentric location of supports. Although, even in excentric location of supports in the apparatus the fixation rigidity is insufficient for early full loading of the traumatized extremity while walking. It is necessary to elaborate such apparatus, the form of which may be adopted toanatomic configuration of segment.

  20. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach.

    Science.gov (United States)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-07-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  1. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-01-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopy-guided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of ≥2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  2. Ti-24Nb-4Zr-8Sn Alloy Pedicle Screw Improves Internal Vertebral Fixation by Reducing Stress-Shielding Effects in a Porcine Model.

    Science.gov (United States)

    Qu, Yang; Zheng, Shuang; Dong, Rongpeng; Kang, Mingyang; Zhou, Haohan; Zhao, Dezhi; Zhao, Jianwu

    2018-01-01

    To ensure the biomechanical properties of Ti-24Nb-4Zr-8Sn, stress-shielding effects were compared between Ti-24Nb-4Zr-8Sn and Ti-6Al-4V fixation by using a porcine model. Twelve thoracolumbar spines (T12-L5) of 12-month-old male pigs were randomly divided into two groups: Ti-24Nb-4Zr-8Sn (EG, n = 6) and Ti-6Al-4V (RG, n = 6) fixation. Pedicle screw was fixed at the outer edge of L4-5 vertebral holes. Fourteen measuring points were selected on the front of transverse process and middle and posterior of L4-5 vertebra. Electronic universal testing machine was used to measure the strain resistance of measuring points after forward and backward flexion loading of 150 N. Meanwhile, stress resistance was compared between both groups. The strain and stress resistance of measurement points 1, 2, 5, 6, 9, and 10-14 in Ti-24Nb-4Zr-8Sn fixation was lower than that of Ti-6Al-4V fixation after forward and backward flexion loading ( P Ti-24Nb-4Zr-8Sn fixation than that of Ti-6Al-4V fixation ( P Ti-24Nb-4Zr-8Sn internal fixation were less than that of Ti-6Al-4V internal fixation. These results suggest that Ti-24Nb-4Zr-8Sn elastic fixation has more biomechanical goals than conventional Ti-6Al-4V internal fixation by reducing stress-shielding effects.

  3. Distal tibial pilon fractures (AO/OTA type B, and C treated with the external skeletal and minimal internal fixation method

    Directory of Open Access Journals (Sweden)

    Milenković Saša

    2013-01-01

    Full Text Available Background/Aim. Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. Methods. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. Results. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60 years. The average follow-up was 21.86 (from 12 to 48 months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20 weeks. There were 4 (12.19% infections around the pins of the external skeletal fixator and one (3.22% deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90% patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. Conclusion. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for

  4. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    Science.gov (United States)

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In

  5. A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated slab fracture in equine third carpal bones.

    Science.gov (United States)

    Bueno, Aloisio C D; Galuppo, Larry D; Taylor, Kenneth T; Jensen, David G; Stover, Susan M

    2003-01-01

    To compare the mechanical shear strengths and stiffnesses obtained from in vitro testing of a simulated complete third carpal bone (C3) frontal plane radial facet slab fracture (osteotomy) stabilized with either a 4/5 Acutrak (AT) compression screw or a 4.5-mm AO cortical bone (AO) screw inserted in lag fashion. Drilling, tapping, and screw insertion torques, forces, and times also were compared between AT and AO implants. In vitro biomechanical assessment of site preparation, screw insertion, and shear failure test variables of bone screw stabilized simulated C3 slab fracture in paired cadaveric equine carpi. Eight pairs of cadaveric equine C3 without orthopedic abnormalities. Standardized simulated C3 slab fractures were repaired with either AO or AT screws (AO/C3 and AT/C3 groups, respectively). Drilling, tapping, and screw insertion torques, forces, and times were measured with a materials testing machine for each screw type. Repaired specimens were tested in axially oriented shear until failure. Paired Students t-tests were used to assess differences between site preparation, screw insertion, and shear testing variables. Significance was set at P bone fragment measurements of the standardized simulated C3 slab fractures created for AO or AT screws. There were no significant differences for mean and maximum drilling torques; however, the tapered AT drill had greater maximum drilling force compared with the 3.2-mm and 4.5-mm AO drill bits. Mean insertion torque and force measured from the self-tapping AT screw were not significantly different compared with the 4.5-mm AO tap. There were no significant differences in maximum screw torque among constructs. Total procedure time was significantly longer for the AT group (5.8 +/- 1.6 minutes) compared with the AO group (2.9 +/- 1.1 minutes; P =.001). AT stabilized specimens had significantly greater mean +/- SD initial shear stiffness (3.64 +/- 1.08 kN/mm) than AO specimens (1.64 +/- 0.73 kN/mm; P =.005). All other

  6. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.

    LENUS (Irish Health Repository)

    McGreal, G

    2012-02-03

    We use a braided polyester suture in place of cerclage wire in tension band fixations. The objective of this study was to test the biomechanical properties of this technique. Sixteen cadaveric patellae were fractured and repaired by modified tension band fixation. Eight were fixed using eighteen gauge stainless steel wire as a tension band and eight using braided polyester. All specimens were subjected to tensile testing. Polyester was 75.0% as strong as wire. For dynamic testing, the patellae of seven cadaveric knees were fractured and then fixed with polyester tension bands. These were mounted in a device capable of extending the knees from 90 degrees to neutral against an applied force. None of the fixations failed. Three of the specimens fixed using 18 gauge stainless steel wire were compared with three fixed using polyester over 2000 cycles of knee flexion and extension. Polyester performed as well as wire. We conclude that polyester is an acceptable alternative to wire in tension band fixation.

  7. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    Science.gov (United States)

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  8. Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

    Science.gov (United States)

    Nebergall, Audrey; Bragdon, Charles; Antonellis, Anne; Kärrholm, Johan; Brånemark, Rickard; Malchau, Henrik

    2012-04-01

    Rehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling. 51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant. At 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up. The RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations.

  9. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    Science.gov (United States)

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use

  10. A randomised prospective study of two different combined internal and external fixation techniques for distal tibia shaft fractures.

    Science.gov (United States)

    Sun, Liao-Jun; Yu, Xian-Bin; Dai, Cheng-Qian; Hu, Wei; Guo, Xiao-Shan; Chen, Hua

    2014-12-01

    External fixation combined with limited open reduction and internal fixation (EF + LORIF) is a well-accepted and effective method for distal tibia shaft fractures, but it was also related to complications. The objective of this study was to compare external fixation combined with closed reduction and internal fixation (EF + CRIF) with EF + LORIF in the treatment of distal tibia shaft fractures, and explore the benefits and defects of these two techniques. Fifty-six patients were randomised to operative stabilisation either by an external fixator combined with two closed titanium elastic nails or by external fixation combined with limited open reduction and internal fixation. Pre-operative variables included the patients’ age, sex, the affected side, cause of injury, Tscherne classification of soft tissue injury, fracture pattern, and time from injury to surgery. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems and other complications, union time, time of recovery to work, the functional American Orthopaedic Foot and Ankle surgery (AOFAS) score. There was no significant difference in the mean operating time (72.6 ± 11.5 vs. 78.5 ± 16.4 min, P = 0.125), the time to union (21.2 ± 11.0 vs. 22.5 ± 12.3 weeks, P = 0.678), the time of recovery to work (25.0 ± 14.5 vs. 26.4 ± 13.6 weeks, P = 0.711), pin track infection (3/28 vs. 4/28, P = 1.000), delayed union (2/28 vs. 3/28, P = 1.000), pain (38.3 ± 1.6 vs. 38.7 ± 1.5, P = 0.339), function (44.4 ± 6.0 vs. 45.0 ± 5.5, P = 0.698), and total AOFAS scores (91.5 ± 7.4 vs. 93.4 ± 6.8, P = 0.322) between the two groups. However, the mean radiation time was longer in the EF + CRIF group than in the EF + LORIF group (2.0 ± 1.2 vs. 0.3 ± 0.1 min, P alignment was obtained in 50 patients (22 in EF + CRIF vs. 28 in EF + LORIF, P = 0.023). Two cases with EF + CRIF had a 6 degrees of recurvatum deformity and four had 6–9 degrees of valgus deformity

  11. Gradual digital lengthening with autologous bone graft and external fixation for correction of flail toe in a patient with Raynaud's disease.

    Science.gov (United States)

    Lamm, Bradley M; Ades, Joe K

    2009-01-01

    Iatrogenic flail toe is a complication of hammertoe surgery that occurs when an overaggressive resection of the proximal phalanx occurs. This can cause both functional and cosmetic concerns for the patient. We present a case report of the correction of a flail second toe in a patient with Raynaud's disease. The correction was achieved by means of gradual soft tissue lengthening with external fixation and an interposition autologous bone graft digital arthrodesis. After 5 months, this 2-stage procedure lengthened, stabilized, and restored the function of the toe. 4.

  12. Posterior Decompression, Lumber Interbody Fusion and Internal Fixation in the Treatment of Upper Lumbar Intervertebral Disc Herniation

    Directory of Open Access Journals (Sweden)

    DONG Zhan

    2014-12-01

    Full Text Available Objective: To assess the clinical outcomes of posterior decompression, interbody fusion and internal fixationfor the treatment of the upper lumbar intervertebral disc herniation. Methods: Twelve patients with the upper lumbar intervertebral disc herniation were treated by posterior decompression, interbosy fusion and internal fixation. The time of the operation, the amount of bleeding and the clinical efficacy were evaluated. Results: The time of operation was (143±36 min and the amount of bleeding during operation was (331.5±47.9 mL. There was no spinal cord and injuries, nerve injury, epidural damage and leakage of cerebrospinal fluid. All patients were followed up for 10~19 months with the average being 12.6 months. The functional scoring of Japanese Orthopedic Association (JOA before the operation was (11.4±3.3 scores and final score after follow-up was (22.9±3.1 scores and there were statistical difference (P<0.01. Lumber interbody fusion of all patients completed successfully and the good rate after the operation was 91.7%. Conclusion: Posterior decompression, interbody fusion and internal fixation for the treatment of the upper lumbar intervertebral disc herniation was characterized by full exposure, safety and significant efficacy.

  13. Stability Following Combined Maxillary and Mandibular Osteotomies Treated with Rigid Internal Fixation.

    Science.gov (United States)

    1987-06-01

    S), articulare (Ar), A point, B point, constructed gonion (CGo), and menton (Me). The points nasion and sella were transferred to each successive...radiograph by superimposing on anterior and posterior cranial base structures. The landmarks articulare , A point, B point, menton, and constructed gonion...reported 45% relapse in their cases determined to be attributed to condylar distraction at the time of surgery. The use of rigid fixation as described

  14. Mid-term functional outcome after the internal fixation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Phadnis Joideep

    2012-01-01

    Full Text Available Abstract Background Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. Methods 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation = 10.4. Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. Results The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74% had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15% and in 11 patients were major (6%. Conclusion This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention.

  15. Surgical site infection after open reduction and internal fixation of tibial plateau fractures.

    Science.gov (United States)

    Lin, Shishui; Mauffrey, Cyril; Hammerberg, E Mark; Stahel, Philip F; Hak, David J

    2014-07-01

    The aim of this study was to identify risk factors for surgical site infections and to quantify the contribution of independent risk factors to the probability of developing infection after definitive fixation of tibial plateau fractures in adult patients. A retrospective analysis was performed at a level I trauma center between January 2004 and December 2010. Data were collected from a review of the patient's electronic medical records. A total of 251 consecutive patients (256 cases) were divided into two groups, those with surgical site infections and those without surgical site infections. Preoperative and perioperative variables were compared between these groups, and risk factors were determined by univariate analyses and multivariate logistic regression. Variables analyzed included age, gender, smoking history, diabetes, presence of an open fracture, presence of compartment syndrome, Schatzker classification, polytrauma status, ICU stay, time from injury to surgery, use of temporary external fixation, surgical approach, surgical fixation, operative time, and use of a drain. The overall rate of surgical site infection after ORIF of tibial plateau fractures during the 7 years of this study was 7.8% (20 of 256). The most common causative pathogens was Staphylococcus aureus (n=15, 75%). Independent predictors of surgical site infection identified by multivariate analyses were open tibial plateau fracture (odds ratio=3.9; 95% CI=1.3-11.6; p=0.015) and operative time (odds ratio=2.7; 95% CI=1.6-4.4; psite infection. Both open fracture and operative time are independent risks factors for postoperative infection.

  16. Development of biodegradable polycaprolactone film as an internal fixation material to enhance tendon repair: an in vitro study.

    Science.gov (United States)

    Hu, Jian-Zhong; Zhou, Yong-Chun; Huang, Li-Hua; Lu, Hong-Bin

    2013-08-19

    Current tendon repair techniques do not provide sufficient tensile strength at the repair site, and thus early active motion rehabilitation after tendon repair is discouraged. To enhance the post-operative tensile strength, we proposed and tested an internal fixation technique using a polycaprolactone (PCL) biofilm. PCL was chosen for its good biocompatibility, excellent mechanical strength, and an appropriate degradation time scale. PCL biofilms were prepared by a modified melt-molding/leaching technique, and the physical and mechanical properties and in vitro degradation rate were assessed. The pore size distribution of the biofilm and the paratenon of native tendons were observed using scanning electron microscopy. Next, we determined whether this biofilm could enhance the tensile strength of repaired tendons. We performed tensile tests on rabbit Achilles tendons that were first lacerated and then repaired: 1) using modified Kessler suture combined with running peripheral suture ('control' group), or 2) using biofilm to wrap the tendon and then fixation with sutures ('biofilm' group). The influence of different repair techniques on tendon tensile strength was evaluated by mechanical testing. The novel biofilm had supple texture and a smooth surface. The mean thickness of the biofilm was 0.25 mm. The mean porosity of the biofilm was 45.3%. The paratenon of the rabbit Achilles tendon had pores with diameters ranging from 1 to 9 μm, which were similar to the 4-12 μm diameter pores in the biofilm cross-section. The weight loss of the biofilms at 4 weeks was only 0.07%. The molecular weight of PCL biofilms did not change after immersion in phosphate buffered saline for 4 weeks. The failure loads of the biofilm were similar before (48 ± 9 N) and after immersion (47 ± 7 N, P > 0.1). The biofilm group had ~70% higher mean failure loads and 93% higher stiffness compared with the control group. We proposed and tested an internal fixation technique

  17. Omnidirectional Internal Fixation by Double Approaches for Treating Rüedi-Allgöwer Type III Pilon Fractures.

    Science.gov (United States)

    Dai, Chong-Hua; Sun, Jun; Chen, Kun-Quan; Zhang, Hui-Bo

    In the present study, we explored the effectiveness and complications of omnidirectional internal fixation using a double approach for treating Rüedi-Allgöwer type III pilon fractures. A retrospective analysis was performed of 19 cases of Rüedi-Allgöwer type III unilateral closed pilon fracture. With preoperative preparation and correct surgical timing, the reduction was performed using anteromedial and posterolateral approaches, and the fracture fragments were fixed by omnidirectional internal fixation. Imaging evaluation was performed using the Burwell-Charnley scoring system. The Johner-Wruhs scoring system was used to assess the functional status of the patients. A comprehensive evaluation of efficacy was performed using a 5-point Likert score. The complications were also recorded and analyzed. All patients were followed up for an average of 16.2 months. The operative incisions of 15 cases healed by primary intent and with delayed healing in 4. All patients had achieved bony union at an average of 16 weeks postoperatively. No deep infection, broken nail or withdrawn nail, exposed plate, or skin flap necrosis occurred. The Burwell-Charnley imaging evaluation showed that 14 patients had anatomic reduction of the articular surface and 5 had acceptable reduction. Using the Johner-Wruhs scoring system, the results were excellent for 8, good for 7, fair for 2, and poor for 2 patients; the combined rate of excellent and good results was 78.9%. The Likert score of efficacy self-reported by the patients was 3 to 4 points for 12 patients, 2 points for 4 patients, and 0 to 1 point for 3 patients. The Likert score of therapeutic efficacy reported by the physicians was 3 to 4 points for 10 patients, 2 points for 5 patients, and 0 to 1 point for 4 patients. Omnidirectional internal fixation using double approaches was an effective method to treat Rüedi-Allgöwer type III pilon fractures with satisfactory reduction and rigid fixation, good joint function recovery, and

  18. Flexible fixation and fracture healing

    DEFF Research Database (Denmark)

    Schmal, Hagen; Strohm, Peter C; Jaeger, Martin

    2011-01-01

    , noncomminuted fractures. External fixation uses external bars for stabilization, whereas internal fixation is realized by subcutaneous placement of locking plates. Both of these "biologic" osteosynthesis methods allow a minimally invasive approach and do not compromise fracture hematoma and periosteal blood...

  19. [A new method of osteosynthesis in proximal humeral fractures: a new internal fixation device. Apropos of 17 cases followed over more than 2 years].

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Touzard, R C

    1996-01-01

    The authors describe a new internal fixation device, and report on 17 proximal humeral fractures managed with this technique. The fracture patterns, using Neer's classification were: 9 displaced three-part fractures, 4 displaced four-part fractures and 4 interior fracture dislocations (mean age of the patients: 70 years). The device is a two-part titanium device. The humeral component has a long vertical stem cemented in the humeral shaft; and a short proximal portion set at an angle of 135 degrees on the stem, with a neck and a Morse taper cone. The other part is a crown-shaped stapple, whose base is a perforated disk with a central Morse taper socket. The rim of the crown has five prongs which, together with the central socket, are impacted in the cancellous bone of the humeral head. The taper of the humeral component is inserted into the central socket of the stapple to provide fracture fixation. Tuberosities are reattached to the shaft with non absorbable sutures. Mean follow-up was 29 months. The global ratings were as follows: 4 excellent results, 6 good results, 4 fair results, 3 poor results. Mean active forward flexion: 100 degrees, and mean active external rotation 22 degrees. After exclusion of the 4 fracture-dislocations, the global rating became: 4 excellent results, 5 good results, 3 fair results, 1 poor result. Mean active forward flexion: 110 degrees and mean active external rotation: 31.5 degrees. There were no case of avascular necrosis in 13 patients. Complications requiring surgery occurred in one case: an upper protrusion of the stapple which required replacement of the stapple by a prosthetic humeral head. Other complications included: 2 asymptomatic partial protrusions of the stapple, 2 complete and two partial avascular necrosis in fracture-dislocations. Except for the fracture-dislocations our device confers several major benefits. The humeral head is preserved. Typical problems associated with joint replacement (dislocations, loosening

  20. Imaging Internal Structure of Long Bones Using Wave Scattering Theory.

    Science.gov (United States)

    Zheng, Rui; Le, Lawrence H; Sacchi, Mauricio D; Lou, Edmond

    2015-11-01

    An ultrasonic wavefield imaging method is developed to reconstruct the internal geometric properties of long bones using zero-offset data acquired axially on the bone surface. The imaging algorithm based on Born scattering theory is implemented with the conjugate gradient iterative method to reconstruct an optimal image. In the case of a multilayered velocity model, ray tracing through a smooth medium is used to calculate the traveled distance and traveling time. The method has been applied to simulated and real data. The results indicate that the interfaces of the top cortex are accurately imaged and correspond favorably to the original model. The reconstructed bottom cortex below the marrow is less accurate mainly because of the low signal-to-noise ratio. The current imaging method has successfully recovered the top cortical layer, providing a potential tool to investigate the internal structures of long bone cortex for osteoporosis assessment. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. CT-guided percutaneous screw fixation plus cementoplasty in the treatment of painful bone metastases with fractures or a high risk of pathological fracture

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio; Ballicu, Nicola; Fele, Rosa Maria; Sotgia, Barbara; Melis, Luca [Oncological Hospital ' ' A. Businco' ' , Regional Referral Center for Oncologic Diseases, Division of Interventional Radiology, Department of Oncological Radiology, Cagliari (Italy); Fancellu, Alessandro [University of Sassari, Department of Clinical and Experimental Medicine, Sassari (Italy)

    2017-04-15

    To evaluate the feasibility and effectiveness of computed tomography (CT)-guided percutaneous screw fixation plus cementoplasty (PSFPC), for either treatment of painful metastatic fractures or prevention of pathological fractures, in patients who are not candidates for surgical stabilization. Twenty-seven patients with 34 metastatic bone lesions underwent CT-guided PSFPC. Bone metastases were located in the vertebral column, femur, and pelvis. The primary end point was the evaluation of feasibility and complications of the procedure, in addition to the length of hospital stay. Pain severity was estimated before treatment and 1 and 6 months after the procedure using the visual analog scale (VAS). Functional outcome was assessed by improved patient walking ability. All sessions were completed and well tolerated. There were no complications related to either incorrect positioning of the screws during bone fixation or leakage of cement. All patients were able to walk within 6 h after the procedure and the average length of hospital stay was 2 days. The mean VAS score decreased from 7.1 (range, 4-9) before treatment to 1.6 (range, 0-6), 1 month after treatment, and to 1.4 (range 0-6) 6 months after treatment. Neither loosening of the screws nor additional bone fractures occurred during a median follow-up of 6 months. Our results suggest that PSFPC might be a safe and effective procedure that allows the stabilization of the fracture and the prevention of pathological fractures with significant pain relief and good recovery of walking ability, although further studies are required to confirm this preliminary experience. (orig.)

  2. Open Reduction and Internal Fixation of displaced Supracondylar Fractures of Humerus with Crossed K-wires via Medial Approach

    Directory of Open Access Journals (Sweden)

    S Hussain

    2014-07-01

    Full Text Available This study aimed at evaluating the medial approach for open reduction and internal fixation of Gartland type 3 displaced supracondylar fractures of humerus in children. A prospective, single centre study of on displaced supracondylar humerus fractures in 42 children was carried out at our institute. All fractures were managed with open reduction and internal fixation with crossed K-wires via medial approach. The mean follow-up was 12 months and patients were assessed according to Flynn’s criteria. No patients had post-operative ulnar nerve injury. Cubitus varus was not seen in any patient. Superficial pin tract infection occurred in three patients that subsided with anti-septic dressings and antibiotics. No deep infection occurred. 88.09 % patients showed satisfactory results as per Flynn’s criteria. The medial approach provides an excellent view of the supracondylar area. The approach is convenient due to a lower risk for ulnar nerve injury and better acceptability of the medial incisional scar.

  3. Dynamic compression plate (DCP) fixation of propagating medial condylar fractures of the third metacarpal/metatarsal bone in 30 racehorses: retrospective analysis (1990-2005).

    Science.gov (United States)

    Goodrich, L R; Nixon, A J; Conway, J D; Morley, P S; Bladon, B M; Hogan, P M

    2014-11-01

    An in-depth review of dynamic compression plate (DCP) fixation of propagating medial condyle fractures of the third metacarpus or metatarsus has not been previously reported. To describe the technique, evaluate short-term outcome and long-term race performance of racehorses that underwent DCP fixation for repair of propagating or spiralling medial condylar fractures of the third metacarpal (McIII) or metatarsal (MtIII) bone. Retrospective case series. The surgical case records of 30 horses with propagating fractures of the medial condyle of McIII or MtIII were reviewed. Medical information included: age, breed, sex, presentation, how injury occurred (racing or training), surgical treatment and post operative complications. Racing information included: starts, top 3 placing and career earnings. Long propagating fractures of the medial condyle of Mc/tIII were identified in 23 Thoroughbred (TB) and 7 Standardbred (STB) racehorses. The fracture spiralled proximally in 22 of 30 cases (73%). Standardbreds had a higher propensity for hindlimb involvement (71%), whereas TBs tended to have more front limb involvement (61%). Twelve of 30 (40%) horses raced post surgery. Career earnings were significantly lower for TB horses with medial condylar fractures; $34,916 when compared with the national average of $60,841 (P≤0.03). Overall, horses having DCP fixation for medial condylar fractures had less starts post surgery (3.1 TBs and 5.8 STBs) compared with the national average (7 TBs and 17.3 STBs) and decreased lifetime starts 13.4 (TBs) compared with 17.3 nationally. Propagating medial condyle fractures can be repaired with plate fixation to potentially lessen the risk of catastrophic fracture destabilisation and return to racing can be expected in 40% of horses. Further prospective studies are warranted comparing lag screw fixation with DCP fixation for repair of severe medial condylar fractures of the metacarpus/metatarsus. © 2013 The Authors. Equine Veterinary Journal

  4. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    Science.gov (United States)

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  5. International longitudinal pediatric reference standards for bone mineral content.

    Science.gov (United States)

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (Paccrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (Paccounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  6. Internal versus external fixation of the anterior component in unstable fractures of the pelvic ring: pooled results from a systematic review.

    Science.gov (United States)

    Wardle, B; Eslick, G D; Sunner, P

    2016-10-01

    Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are

  7. Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: experimental study in a porcine model.

    Science.gov (United States)

    Ohe, Makoto; Moridaira, Hiroshi; Inami, Satoshi; Takeuchi, Daisaku; Nohara, Yutaka; Taneichi, Hiroshi

    2018-03-30

    strengthens bonding at the BII, which might improve early implant fixation after spinal surgery for osteoporosis. However, the absence of increased bone mass around the screw remains a concern; prescribing osteoporosis treatment to improve bone quality might be necessary to prevent fractures around the screws.

  8. The role of bone SPECT/CT in the evaluation of lumbar spinal fusion with metallic fixation devices

    DEFF Research Database (Denmark)

    Damgaard, Morten; Nimb, Lars; Madsen, Jan L

    2010-01-01

    PURPOSE: It is difficult to evaluate the stability of the lumbar spondylodesis with metallic fixation devices by conventional imaging methods such as radiography or magnetic resonance imaging. It is unknown whether single photon emission computed tomography/computed tomography (SPECT/CT) may be u...

  9. Macro-structural effect of metal surfaces treated using computer-assisted yttrium-aluminum-garnet laser scanning on bone-implant fixation.

    Science.gov (United States)

    Hirao, Makoto; Sugamoto, Kazuomi; Tamai, Noriyuki; Oka, Kunihiro; Yoshikawa, Hideki; Mori, Yusuke; Sasaki, Takatomo

    2005-05-01

    Porous coatings have been applied to the surface of prosthetic devices to foster stable device fixation. The coating serves as a source of mechanical interlocking and may stimulate healthy bone growth through osseointegrated load transfer in cementless arthroplasty. Joint arthroplasty by porous-coated prostheses is one of the most common surgical treatments, and has provided painless and successful joint mobility. However, long-term success is often impaired by the loss of fixation between the prosthesis and bone. Porous-coated prostheses are associated with several disadvantages, including metal debris from porous coatings (third body wear particles) and irregular micro-texture of metal surfaces. Consequently, quantitative histological analysis has been very difficult. These issues arise because the porous coating treatment is based on addition of material and is not precisely controllable. We recently developed a precisely controllable porous texture technique based on material removal by yttrium-aluminum-garnet laser. Free shapes can be applied to complex, three-dimensional hard metal surfaces using this technique. In this study, tartan check shapes made by crossing grooves and dot shapes made by forming holes were produced on titanium (Ti6A14V) or cobalt chrome (CoCr) and evaluated with computer-assisted histological analysis and measurement of bone-metal interface shear strength. Width of grooves or holes ranged from 100 to 800 mum (100, 200, 500, and 800 microm), with a depth of 500 microm. When the cylindrical porous-texture-treated metal samples (diameter, 5 mm; height, 15 mm) were implanted into a rabbit femoral condyle, bone tissue with bone trabeculae formed in the grooves and holes after 2 or 4 weeks, especially in 500-microm-wide grooves. Abundant osteoconduction was consistently observed throughout 500-microm-wide grooves in both Ti6A14V and CoCr. Speed of osteoconduction was faster in Ti6A14V than in CoCr, especially in the tartan check shape made of

  10. Open reduction and internal fixation of intra-articular fractures of the mandibular condyle: our first experiences.

    Science.gov (United States)

    Vesnaver, Ales

    2008-10-01

    Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.

  11. Posterior Cruciate Ligament Tibial Avulsion treated with Open Reduction and Internal Fixation through the Burks and Schaffer Approach

    Directory of Open Access Journals (Sweden)

    Khatri K

    2015-07-01

    Full Text Available Objective: To report functional outcome in Posterior Cruciate Ligament (PCL tibial avulsion fractures treated with open reduction and internal fixation through Burks and Schaffer approach. The patient specific functional outcome measures like IKDC grading together with objective grading with stress radiographs have rarely been used to assess PCL tibial avulsion fractures. Material and Methods: Twenty seven patients (21 males and 6 females were included in the study. The mean follow up duration was 22.30±6.82 months. They were assessed using international knee documentation committee (IKDC grades, Lysholm scoring and stress radiography. The injury severity scores (ISS of the patients were also recorded. Results: The mean Lysholm scores at the time of last follow up was 90.85±5.58. The IKDC grades achieved were normal in 20 patients, near normal in five and abnormal in two. The PCL laxity determined on active hamstring contraction stress radiography was grade I in 20 cases and grade II in seven cases. All patients had achieved bony union of tibial avulsion fractures at the time of last follow up. Statistically significant association was found between higher ISS and lower Lysholm scores. (t=3.455, p=0.0019. Good IKDC grades were associated with higher Lysholm scores (analysis of variance, F=32.51, p<.0001.There was no correlation between PCL laxity and functional outcome (t=.857, p =0.399. Conclusion: PCL tibial avulsion fractures treated through Burk and Schaffer approach with open reduction and internal fixation produces good results. The early rehabilitation without cast immobilisation prevents arthrofibrosis.

  12. Bone grafting via reamer-irrigator-aspirator for nonunion of open Gustilo-Anderson type III tibial fractures treated with multiplanar external fixator

    Directory of Open Access Journals (Sweden)

    Kusnezov Nicholas

    2017-01-01

    Full Text Available Introduction: The purpose of this investigation was to evaluate the outcomes following reamer-irrigator-aspirator (RIA autogenous bone grafting (ABG of high-grade open tibia fracture nonunions stabilized via multiplanar external fixation. Methods: We retrospectively reviewed all patients with Gustilo-Anderson type III open tibia fractures treated with multiplanar external fixation and who underwent RIA ABG for nonunion at our institutional Level 1 Trauma Center between 2008 and 2015. All patients between 15 and 65 years of age with a minimum of six-month follow-up were included. The primary outcomes of interest were achievement of union, time to union, and incidence of revision surgery. Complications and all-cause reoperation were recorded as secondary endpoints. Results: Fifteen patients met the inclusion criteria with a mean age of 41.1 ± 14.0 years. RIA ABG was harvested from the femur in all cases, with a mean volume of 34 ± 15 mL. At an average follow-up of 13.3 ± 6.8 months, all patients achieved union, including two who required repeat RIA ABG. One patient experienced a femoral shaft fracture four months following RIA that required intramedullary fixation. The average time to union was 6.0 ± 6.3 months. Twelve patients (80% went on to union within six months and 13 (86.7% within one year. Five patients experienced a total of six post-operative complications including three deep infections, one refracture through the nonunion site, and one gradual varus deformity. Two patients in this series required a subsequent RIA autografting procedure secondary to persistent nonunion despite initial RIA. Conclusion: We found that RIA ABG offered a reliable solution to nonunion of Gustilo-Anderson type III open tibial fractures treated with multiplanar external fixation, circumventing the need to change the method of fixation.

  13. Open reduction and internal fixation of dislocated condylar fractures in children: long-term clinical and radiologic outcomes.

    Science.gov (United States)

    Deleyiannis, Frederic W-B; Vecchione, Lisa; Martin, Brian; Jiang, Shao; Sotereanos, George

    2006-11-01

    The purpose of this study was to investigate the long-term clinical and radiologic outcomes of treating dislocated condylar fractures sustained in childhood with open reduction and internal fixation (ORIF). Six children 14 years or younger with a condylar neck or subcondylar fracture with dislocation of the condyle from the glenoid fossa were treated with ORIF. Patients were followed for 27 to 92 months post-ORIF (mean: 67.6 months) with routine clinical and radiologic examinations. On the dislocated side, all patients radiographically showed signs of remodeling of the condylar process and shortening of the ramus. Subsequent to their fractures, 3 patients were classified with Angle class II malocclusion, retrognathism, and deviation of the mandibular symphysis. Four patients had objective and/or subjective signs of temporomandibular (TMJ) dysfunction. Until open surgery demonstrates a consistent functional advantage, nonsurgical management should be considered the first treatment option for the dislocated pediatric condylar fracture.

  14. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  15. The new concept of the monitoring and appraisal of bone union inflexibility of fractures treated by Dynastab DK external fixator.

    Science.gov (United States)

    Lenz, Gerhard P; Stasiak, Andrzej; Deszczyński, Jarosław; Karpiński, Janusz; Stolarczyk, Artur; Ziółkowski, Marcin; Szczesny, Grzegorz

    2003-10-30

    Background. This work focuses on problems of heuristic techniques based on artificial intelligence. Mainly about artificial non-linear and multilayer neurons, which were used to estimate the bone union fractures treatment process using orthopaedic stabilizers Dynastab DK. Material and methods. The author utilizes computer software based on multilayer neuronal network systems, which allows to predict the curve of the bone union at early stages of therapy. The training of the neural net has been made on fifty six cases of bone fracture which has been cured by the Dynastab stabilizers DK. Using such trained net, seventeen fractures of long bones shafts were being examined on strength and prediction of the bone union as well. Results. Analyzing results, it should be underlined that mechanical properties of the bone union in the slot of fracture are changing in nonlinear way in function of time. Especially, major changes were observed during the forth month of the fracture treatment. There is strong correlation between measure number two and measure number six. Measure number two is more strict and in the matter of fact it refers to flexion, as well as the measure number six, to compression of the bone in the fracture slot. Conclusions. Consequently, deflection loads are especially hazardous for healing bone. The very strong correlation between real curves and predicted curves shows the correctness of the neuronal model.

  16. The initial instability of cemented and non-cemented femoral stems fixated with a bone grafting technique

    NARCIS (Netherlands)

    Schreurs, B.W.; Huiskes, H.W.J.; Slooff, T.J.J.H.

    1994-01-01

    To reconstruct intramedullary bone stock in revision surgery of failed total hip arthroplasties, a method was developed using impacted trabecular bone grafts. In an in vitro model with femora of the goat, the initial stabilities of both cemented and non-cemented hydroxylapatite-coated stems in this

  17. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    Science.gov (United States)

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  18. Internal fixation versus conservative treatment for elderly patients with a trochanteric hip fracture in conjunction with post-stroke hemiplegia.

    Science.gov (United States)

    Li, Kainan; Zheng, Yingjie

    2016-10-01

    To retrospectively evaluated Gamma nail internal fixation in the treatment of elderly patients with post-stroke hemiplegia experiencing trochanteric hip fracture. The patients were obtained consecutively from January 2005 to December 2010 with inclusion criteria. The total number was 138 and allocated to two groups: treated with the Gamma nail (n=72,group A) and continuous skin traction (n=66,group B). Preoperative variables including patient age, gender, duration of cerebrovascular accident, duration of hypertension, ASA risk score, Harris hip score and fracture type were recorded and compared. After treatment, time of patients activity on the bed, ambulation time, Harris hip score, mortality, complications were recorded and used to compare the outcomes. (1) Follow-up was undertaken from 3 to 10 years, with an average of 5.8 years. (2) No statistical difference in preoperative variables was found between the 2 groups. (3) two groups had statistical significance (P=0.000) in the time of patients activity on the bed and ambulation time and group A can activities on the bed and ambulates earlier. (4) There were significant differences between 2 groups in Harris hip score at 1 and 3 years and group A was significantly higher than group B. (5) there were statistically significant differences in mortality of 3 years, 5 years and 10 years and the group B was significantly higher than the group A. (6) There was a statistical significance in complications between 2 groups and group B was higher than group A. Major complications in group A were pain, lag screw cut out, implant infection and distal femoral fractures caused by fall after the surgery. On elderly patients with trochanteric hip fracture on the hemiplegic lower side, Gamma nail internal fixation treatment can achieve better effect, patients can be early activity, fewer complications, and less mortality. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Efficacy of open reduction and internal fixation with a miniplate and hollow screw in the treatment of Lisfranc injury

    Directory of Open Access Journals (Sweden)

    Li Baoliang

    2015-07-01

    Full Text Available Purpose: To investigate efficacy of open reduction and internal fixation with the miniplate and hollow screw in the treatment of Lisfranc injury. Methods: Ten cases of Lisfranc injury treated by open reduction, miniplate and hollow screw in our hospital were retrospectively analyzed. There were 6 males and 4 females with age ranging from 25 to 45 years (mean 32 years. Among them, one case was classified as Type A, six Type B and three Type C. Injury mechanism included road traffic accidents (3 cases, fall from height (5 cases and hit by heavy object (2 cases. All injuries were closed without cerebral trauma or other complicated injuries. The time interval between injury and operation was 6e10 days (average 6.6 days. Postoperatively, the foot function was assessed using Visual Analogue Scales (VAS and American Orthopaedic Foot and Ankle Society (AOFAS Scales. Healing time and complications were observed. Results: All patients were followed up for 18e24 months (average 20 months. Anatomic reduction was achieved in all patients on images. There was statistical significance between preoperative score (7.89 ± 0.34 and score at postoperative 8 weeks (0.67 ± 0.13. According to the AOFAS score, 5 cases were defined as excellent, 3 cases as good and 2 cases as fair. During follow-up, there was no wound infection or complications except for osteoarthritis in 2 cases. Healing time ranged from 3 to 6 months with an average of 3.6 months. Conclusion: Anatomical reduction of Lisfranc injury can be achieved by open reduction and internal fixation with the miniplate and hollow screw. Normal structure of Lisfranc joint is regained to a great extent; injured ligaments were also repaired. Therefore, this method offers excellent curative effect and can avoid postoperative complications and improve the patients' quality of life.

  20. [Case-control study on the relationship between pain and knee function after the internal fixation of femoral fractures].

    Science.gov (United States)

    Dai, Ming-hai; Tang, Cheng-xuan; Yang, Guo-jing; Zhang, Li-cheng; Tang, Xiao-jun; Liu, Liang-le

    2011-09-01

    To investigate the relationship between pain and knee function after the internal fixation of femoral fractures. The clinical data of 73 patients after internal fixation on femoral fractures from June 2006 to December 2009 were retrospectively analyzed. All the patients were divided into two groups according to the degree of postoperative pain: low score group and high score group. Among the 39 patients in low score group (VAS 1 to 5 point), 25 patients were male and 14 patients were female, with a mean age of (37.5 +/- 5.3) years (ranged from 27 to 63 years ). Among 34 patients in high score group (VAS 6 to 10 point), 22 patients were male and 12 patients were female, with a mean age of (36.3 +/- 9.6) years (ranged from 29 to 62 years). The intra-articular pressure of knee and hospital for special surgery knee rating scale (HSS) were recorded and analyzed. All the patients were followed up for an average duration of 24.1 months. The intra-articular pressure of knee was rising for two groups, there were significant difference for the high score group compared with the low score group at 3 days after operation (t=15.67, P=0.000) and the end time of follow up (t=5.63, P=0.000). As to knee joint function, in low score group, 21 patients got an excellent result, 4 good, 7 poor and 2 bad; in high score group, 31 patients got an excellent result, 6 good, 2 poor and no bad. The knee function of low score group was better than that of high score group. The intra-articular pressure of knee is an important factor of the knee functional recovery, and its external symptoms of pain can be seen as an important index to forecast the prognosins of knee function in early time.

  1. Experimental investigation of temperature rise in bone drilling with cooling: A comparison between modes of without cooling, internal gas cooling, and external liquid cooling.

    Science.gov (United States)

    Shakouri, Ehsan; Haghighi Hassanalideh, Hossein; Gholampour, Seifollah

    2018-01-01

    Bone fracture occurs due to accident, aging, and disease. For the treatment of bone fractures, it is essential that the bones are kept fixed in the right place. In complex fractures, internal fixation or external methods are used to fix the fracture position. In order to immobilize the fracture position and connect the holder equipment to it, bone drilling is required. During the drilling of the bone, the required forces to chip formation could cause an increase in the temperature. If the resulting temperature increases to 47 °C, it causes thermal necrosis of the bone. Thermal necrosis decreases bone strength in the hole and, subsequently, due to incomplete immobilization of bone, fracture repair is not performed correctly. In this study, attempts have been made to compare local temperature increases in different processes of bone drilling. This comparison has been done between drilling without cooling, drilling with gas cooling, and liquid cooling on bovine femur. Drilling tests with gas coolant using direct injection of CO 2 and N 2 gases were carried out by internal coolant drill bit. The results showed that with the use of gas coolant, the elevation of temperature has limited to 6 °C and the thermal necrosis is prevented. Maximum temperature rise reached in drilling without cooling was 56 °C, using gas and liquid coolant, a maximum temperature elevation of 43 °C and 42 °C have been obtained, respectively. This resulted in decreased possibility of thermal necrosis of bone in drilling with gas and liquid cooling. However, the results showed that the values obtained with the drilling method with direct gas cooling are independent of the rotational speed of drill.

  2. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    Science.gov (United States)

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA

  3. Pitfalls associated with open reduction and internal fixation of fractured ribs.

    Science.gov (United States)

    Sarani, Babak; Schulte, Leah; Diaz, Jose J

    2015-12-01

    Rib fracture is exceedingly common and remains a leading cause of death in patients with chest injury. Probability of death increases by 19% with each broken rib, and the probability of death increases further with age. Treatment is centered on pain control and early mobilization to provide adequate pulmonary hygiene. Multimodality interventions, such as incentive spirometry, postural changes, and coughing, are pivotal in minimizing the risk of pneumonia and death. Recently, many studies have found mortality benefit to operation fixation (ORIF) of ribs in select patients. However, this procedure remains underutilized partly due to lack of familiarity with its technique and pitfalls by trauma surgeons, in particular. Whereas there are publications on operative technique, there are no studies describing pitfalls associated with this procedure. The purpose of this paper is to describe pitfalls on the technical aspects of ORIF of the ribs based on the medical literature where possible and based on our experience in instances where peer reviewed evidence is lacking. The paper is not meant to serve as a protocol for managing rib fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Design of complex bone internal structure using topology optimization with perimeter control.

    Science.gov (United States)

    Park, Jaejong; Sutradhar, Alok; Shah, Jami J; Paulino, Glaucio H

    2018-03-01

    Large facial bone loss usually requires patient-specific bone implants to restore the structural integrity and functionality that also affects the appearance of each patient. Titanium alloys (e.g., Ti-6Al-4V) are typically used in the interfacial porous coatings between the implant and the surrounding bone to promote stability. There exists a property mismatch between the two that in general leads to complications such as stress-shielding. This biomechanical discrepancy is a hurdle in the design of bone replacements. To alleviate the mismatch, the internal structure of the bone replacements should match that of the bone. Topology optimization has proven to be a good technique for designing bone replacements. However, the complex internal structure of the bone is difficult to mimic using conventional topology optimization methods without additional restrictions. In this work, the complex bone internal structure is recovered using a perimeter control based topology optimization approach. By restricting the solution space by means of the perimeter, the intricate design complexity of bones can be achieved. Three different bone regions with well-known physiological loadings are selected to illustrate the method. Additionally, we found that the target perimeter value and the pattern of the initial distribution play a vital role in obtaining the natural curvatures in the bone internal structures as well as avoiding excessive island patterns. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Risk factors for medical complications after long-level internal fixation in the treatment of adult degenerative scoliosis.

    Science.gov (United States)

    Zhang, Xi-Nuo; Sun, Xiang-Yao; Meng, Xiang-Long; Hai, Yong

    2018-04-13

    This study evaluates baseline patient characteristics and surgical parameters for risk factors of medical complications in ASD patients received posterior long level internal fixation. Analysis of consecutive patients who underwent posterior long-level instruction fixation for adult degenerative scoliosis (ADS) with a minimum of two year follow-up was performed. Pre-operative risk factors, intraoperative variables, peri-operative radiographic parameters, and surgical-related risk factors were collected to analyze the effect of risk factors on medical complications. Patients were separated into groups with and without medical complication. Then, complication group was further classified as major or minor medical complications. Potential risk factors were identified by univariate testing. Multivariate logistic regression was used to evaluate independent predictors of medical complications. One hundred and thirty-one ADS patients who underwent posterior long segment pedicle screws fixation were included. Total medical complication incidence was 25.2%, which included infection (12.2%), neurological (11.5%), cardiopulmonary (7.6%), gastrointestinal (6.1%), and renal (1.5%) complications. Overall, 7.6% of patients developed major medical complications, and 17.6% of patients developed minor medical complications. The radiographic parameters of pre-operative and last follow-up had no significant difference between the groups of medical complications and the major or minor medical complications subgroups. However, the incidence of cerebrospinal fluid leak (CFL) in patients who without medical complications was much lower than that with medical complications (18.4 vs. 42.4%, P = 0.005). Independent risk factors for development of medical complications included smoking (OR = 6.45, P = 0.012), heart disease (OR = 10.07, P = 0.012), fusion level (OR = 2.12, P = 0.001), and length of hospital stay (LOS) (OR = 2.11, P = 0.000). Independent

  6. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up.

    Science.gov (United States)

    Flivik, G; Kristiansson, I; Ryd, L

    2015-01-01

    We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement-bone interface in order to maximise acetabular component stability and longevity. ©2015 The British Editorial Society of Bone & Joint Surgery.

  7. A biomechanical comparison of headless tapered variable pitch compression and ao cortical bone screws for fixation of a simulated midbody transverse fracture of the proximal sesamoid bone in horses.

    Science.gov (United States)

    Eddy, Alison L; Galuppo, Larry D; Stover, Susan M; Taylor, Kenneth T; Jensen, David G

    2004-01-01

    To compare mechanical properties and failure characteristics of 2 methods of fixation for repair of a transverse, midbody fracture of the proximal sesamoid bone (PSB): 4.5-mm AO cortical bone screw (AO) placed in lag fashion and 4/5-mm Acutrak (AT) self-compressing screw. An in vitro biomechanical evaluation of intact forelimb preparations and forelimb preparations with a simulated midbody PSB fracture stabilized by a bone screw. Sixteen paired and 8 unilateral cadaveric equine forelimbs. A midbody transverse osteotomy was created in the medial PSB of bilateral forelimbs of 8 equine cadavers. The osteotomized PSB in 1 forelimb from each cadaver was repaired with an AO screw. The osteotomized PSB in each contralateral limb was repaired with an AT screw. Eight unilateral intact control limbs were also studied. Mechanical properties were determined from axial compression, single cycle to failure, load-deformation curves. Failure characteristics were determined by evaluation of video images and radiographs. No statistically significant differences were found between repair groups. Both AO and AT groups had significantly lower mechanical properties than intact limbs except for stiffness. AO and AT constructs were mechanically comparable when used to stabilize a simulated midbody fracture of the medial PSB. Both constructs were mechanically inferior to intact limbs. Clinical Relevance- The AT screw should be considered for clinical use because of the potential for less soft tissue impingement and superior biocompatibility compared with the stainless-steel AO screw. However, postoperative external coaptation is necessary to augment initial fracture stability for either fixation method, and to maintain a standing metacarpophalangeal joint dorsiflexion angle between 150 degrees and 155 degrees.

  8. FUNCTIONAL OUTCOME OF INTERNAL FIXATION FOR DISPLACED INTRA-ARTICULAR CALCANEAL FRACTURE

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND There are always difference of opinion in the importance of Bohler’s angle in evaluating the severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following surgical fixation. The purpose of this research, the relationship exists between Bohler’s angle and the injury severity of displaced calcaneal fractures and between surgical improvement of Bohler’s angle and its practical outcome. MATERIALS AND METHODS Patients were treated surgically for unilateral closed displaced intra-articular calcaneal fractures from May 2014 to October 2016 were identified. The Bohler’s angles of bilateral calcaneus were measured and was compared to the dimension of the uninjured foot was used as its normal control. The difference in the value of Bohler’s angle measured preoperatively or after surgery between the angle of the damaged foot and that of the contralateral calcaneus was calculated, respectively. The change in Bohler’s angle by ratio was calculated by dividing the variation in the value of Bohler’s angle between bilateral calcaneus by its typical control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot and Ankle Society hindfoot scores. RESULTS 30 patients were included into the study with a mean follow-up duration of 30 months. According to Sanders classification, the fracture pattern included 12 type II, 10 type III and 8 type IV fractures. According to American Orthopaedic Foot and Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 10, 8, 4 and 2 patients, respectively. The preoperative Bohler’s angle, difference value of Bohler’s angle between bilateral calcaneus and change in Bohler’s angle by ratio each has a significant relationship with Sanders classification (P=0.003; P=0.004; P=0.005, respectively, however, is not correlated with

  9. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    Science.gov (United States)

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  10. International conference on bone mineral measurement, October 12--13, 1973, Chicago, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    None

    1973-12-31

    From international conference on bone mineral measurement; Chicago, Illinois, USA (12 Oct 1973). Abstracts of papers presented at the international conference on bone mineral measurement are presented. The papers were grouped into two sessions: a physical session including papers on measuring techniques, errors, interpretation and correlations, dual photon techniques, and data handling and exchange; a biomedical session including papers on bone disease, osteoporosis, normative data, non-disease influences, renal, and activity and inactivity. (ERB)

  11. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  12. Ipsilateral Femoral Fracture Non-Union and Delayed Union Treated By Hybrid Plate Nail Fixation and Vascularized Fibula Bone Grafting: A Case Report

    Directory of Open Access Journals (Sweden)

    CK Chan

    2013-07-01

    Full Text Available Non-union is a well recognized complication of femoral neck fractures. The decision whether to attempt fracture fixation or to resort to hip replacement is particularly difficult in patients in the borderline age group in whom complex attempts at gaining union may fail and later present a difficult revision. On the other hand the patient may be young enough that arthroplasty best be avoided . Besides, presence of ipsilateral femoral shaft fracture with delayed union in addition to the femoral neck non-union will pose major problems at operation. We share our experience in treating a femoral neck fracture non-union with ipsilateral femoral shaft delayed union in the shaft and in the distal femur in a fifty years old patient. The fracture was treated with an angle blade plate and supracondylar nail supplemented with a free vascularised fibular bone grafting and autologous cancellous graft. There was radiological union at fourth month. At sixth months, the patient was free of pain and able to walk without support. Thus, we would like to suggest that vascularised fibula bone grafting with supracondylar nailing is a viable option for this pattern of fracture.

  13. A Novel Surgical Technique for Fixation of Recurrent Acromioclavicular Dislocations: AC Dog Bone Technique in Combination with Autogenous Semitendinosus Tendon Graft

    Directory of Open Access Journals (Sweden)

    Patrick Holweg

    2017-01-01

    Full Text Available Various surgical techniques have been described for the fixation of acromioclavicular (AC dislocations. However, recurrent dislocation is one of the main complications associated with the majority of these techniques. We report a case of postoperative AC joint redislocation. In order to overcome recurrent dislocation after revision surgery, a reconstruction of the conoid and trapezoid ligament with the use of a free tendon graft in combination with a FiberTape was provided within a novel surgical technique. After 12 months, the patient was very satisfied with the functional outcome. The patient achieved excellent results in the Constant (98 points, SPADI (0 points, and QuickDASH score (0 points. The described technique results in an anatomic reconstruction of the AC joint. The nonrigid nature of the intervention seems to restore the normal arthrokinematics by reconstructing the coracoclavicular ligaments with an autograft which is then protected by the AC Dog Bone artificial ligaments during the healing period. The arthroscopic approach to the AC joint with minimal exposure reduces the risks and complications of the intervention. This is the first case in literature that utilizes the artificial dog bone ligament securing the autograft in an anatomic AC reconstruction.

  14. Fracture fixation in the operative management of hip fractures (FAITH) : an international, multicentre, randomised controlled trial

    NARCIS (Netherlands)

    Nauth, Aaron; Creek, Aaron T.; Zellar, Abby; Lawendy, Abdel Rahman; Dowrick, Adam; Gupta, Ajay; Dadi, Akhil; van Kampen, Albert; Yee, Albert; de Vries, Alexander C.; de Mol van Otterloo, Alexander; Garibaldi, Alisha; Liew, Allen; McIntyre, Allison W.; Prasad, Amal Shankar; Romero, Amanda W.; Rangan, Amar; Oatt, Amber; Sanghavi, Amir; Foley, Amy L.; Karlsten, Anders; Dolenc, Andrea; Bucknill, Andrew; Chia, Andrew; Evans, Andrew; Gong, Andrew; Schmidt, Andrew H.; Marcantonio, Andrew J.; Jennings, Andrew; Ward, Angela; Khanna, Angshuman; Rai, Anil; Smits, Anke B; Horan, Annamarie D.; Brekke, Anne Christine; Flynn, Annette; Duraikannan, Aravin; Stødle, Are; van Vugt, Arie B.; Luther, Arlene; Zurcher, Arthur W.; Jain, Arvind; Amundsen, Asgeir; Moaveni, Ash; Carr, Ashley; Sharma, Ateet; Hill, Austin D.; Trommer, Axel; Rai, B. Sachidananda; Hileman, Barbara; Schreurs, Bart; Verhoeven, Bart A N; Barden, Benjamin B.; Flatøy, Bernhard; Cleffken, Berry I.; Bøe, Berthe; Perey, Bertrand; Hanusch, Birgit C.; Weening, Brad; Fioole, Bram; Rijbroek, Bram; Crist, Brett D.; Halliday, Brett; Peterson, Brett; Mullis, Brian; Richardson, C. Glen; Clark, Callum; Sagebien, Carlos A.; van der Pol, Carmen C.; Bowler, Carol; Humphrey, Catherine A.; Coady, Catherine; Koppert, Cees L.; Coles, Chad; Tannoury, Chadi; DePaolo, Charles J.; Gayton, Chris; Herriott, Chris; Reeves, Christina; Tieszer, Christina; Dobb, Christine; Anderson, Christopher G.; Sage, Claire; Cuento, Claudine; Jones, Clifford B.; Bosman, Coks H.R.; Linehan, Colleen; van der Hart, Cor P.; Henderson, Corey; Lewis, Courtland G.; Davis, Craig A.; Donohue, Craig; Mauffrey, Cyril; Sundaresh, D. C.; Farrell, Dana J.; Whelan, Daniel B.; Horwitz, Daniel; Stinner, Daniel; Viskontas, Darius; Roffey, Darren M.; Alexander, David; Karges, David E.; Hak, David; Johnston, David; Love, David; Wright, David M.; Zamorano, David P.; Goetz, David R.; Sanders, David; Stephen, David; Yen, David; Bardana, Davide; Olakkengil, Davy J.; Lawson, Deanna; Maddock, Deborah; Sietsema, Debra L.; Pourmand, Deeba; Den Hartog, Dennis; Donegan, Derek; Heels-Ansdell, Diane; Nam, Diane; Inman, Dominic; Boyer, Dory; Li, Doug; Gibula, Douglas; Price, Dustin M.; Watson, Dylan J.; Hammerberg, E. Mark; Tan, Edward C T H; de Graaf, Eelco J.R.; Vesterhus, Elise Berg; Roper, Elizabeth; Edwards, Elton; Schemitsch, Emil H.; Hammacher, Eric R.; Henderson, Eric R.; Whatley, Erica; Torres, Erick T.; Vermeulen, Erik G.J.; Finn, Erin; Van Lieshout, Esther M M; Wai, Eugene K.; Bannister, Evan R.; Kile, Evelyn; Theunissen, Evert B.M.; Ritchie, Ewan D.; Khan, Farah; Moola, Farhad; Howells, Fiona; de Nies, Frank; van der Heijden, Frank H.W.M.; de Meulemeester, Frank R.A.J.; Frihagen, Frede; Nilsen, Fredrik; Schmidt, G. Ben; Albers, G. H.Robert; Gudger, Garland K.; Johnson, Garth; Gruen, Gary; Zohman, Gary; Sharma, Gaurav; Wood, Gavin; Tetteroo, Geert W.M.; Hjorthaug, Geir; Jomaas, Geir; Donald, Geoff; Rieser, Geoffrey Ryan; Reardon, Gerald; Slobogean, Gerard P.; Roukema, Gert R.; Visser, Gijs A.; Moatshe, Gilbert; Horner, Gillian; Rose, Glynis; Guyatt, Gordon; Chuter, Graham; Etherington, Greg; Rocca, Gregory J.Della; Ekås, Guri; Dobbin, Gwendolyn; Lemke, H. Michael; Curry, Hamish; Boxma, Han; Gissel, Hannah; Kreder, Hans; Kuiken, Hans; Brom, Hans L.F.; Pape, Hans Christoph; van der Vis, Harm M.; Bedi, Harvinder; Vallier, Heather A.; Brien, Heather; Silva, Heather; Newman, Heike; Viveiros, Helena; van der Hoeven, Henk; Ahn, Henry; Johal, Herman; Rijna, Herman; Stockmann, Heyn; Josaputra, Hong A.; Carlisle, Hope; van der Brand, Igor; Dawson, Imro; Tarkin, Ivan; Wong, Ivan; Parr, J. Andrew; Trenholm, J. Andrew; Goslings, J Carel; Amirault, J. David; Broderick, J. Scott; Snellen, Jaap P.; Zijl, Jacco A.C.; Ahn, Jaimo; Ficke, James; Irrgang, James; Powell, James; Ringler, James R.; Shaer, James; Monica, James T.; Biert, Jan; Bosma, Jan; Brattgjerd, Jan Egil; Frölke, Jan Paul M.; Wille, Jan; Rajakumar, Janakiraman; Walker, Jane E.; Baker, Janell K.; Ertl, Janos P.; De Vries, Jean-Paul P. M.; Gardeniers, Jean W.M.; May, Jedediah; Yach, Jeff; Hidy, Jennifer T.; Westberg, Jerald R.; Hall, Jeremy A.; van Mulken, Jeroen; McBeth, Jessica Cooper; Hoogendoorn, Jochem M; Hoffman, Jodi M.; Cherian, Joe Joseph; Tanksley, John A.; Clarke-Jenssen, John; Adams, John D.; Esterhai, John; Tilzey, John F.; Murnaghan, John; Ketz, John P.; Garfi, John S.; Schwappach, John; Gorczyca, John T.; Wyrick, John; Rydinge, Jonas; Foret, Jonathan L.; Gross, Jonathan M.; Keeve, Jonathan P.; Meijer, Joost; Scheepers, Joris J.G.; Baele, Joseph; O'Neil, Joseph; Cass, Joseph R.; Hsu, Joseph R.; Dumais, Jules; Lee, Julia; Switzer, Julie A.; Agel, Julie; Richards, Justin E.; Langan, Justin W.; Turckan, Kahn; Pecorella, Kaili; Rai, Kamal; Aurang, Kamran; Shively, Karl; van Wessem, Karlijn; Moon, Karyn; Eke, Kate; Erwin, Katie; Milner, Katrine; Ponsen, Kees Jan; Mills, Kelli; Apostle, Kelly; Johnston, Kelly; Trask, Kelly; Strohecker, Kent; Stringfellow, Kenya; Kruse, Kevin K.; Tetsworth, Kevin; Mitchell, Khalis; Browner, Kieran; Hemlock, Kim; Carcary, Kimberly; Jørgen Haug, Knut; Noble, Krista; Robbins, Kristin; Payton, Krystal; Jeray, Kyle J.; Rubino, L. Joseph; Nastoff, Lauren A.; Leffler, Lauren C.; Stassen, Laurents P.S.; O'Malley, Lawrence K.; Specht, Lawrence M.; Thabane, Lehana; Geeraedts, Leo M.G.; Shell, Leslie E.; Anderson, Linda K.; Eickhoff, Linda S.; Lyle, Lindsey; Pilling, Lindsey; Buckingham, Lisa; Cannada, Lisa K.; Wild, Lisa M.; Dulaney-Cripe, Liz; Poelhekke, Lodewijk M.S.J.; Govaert, Lonneke; Ton, Lu; Kottam, Lucksy; Leenen, Luke P.H.; Clipper, Lydia; Jackson, Lyle T.; Hampton, Lynne; de Waal Malefijt, Maarten C.; Simons, Maarten P.; van der Elst, Maarten; Bronkhorst, Maarten W.G.A.; Bhatia, Mahesh; Swiontkowski, Marc; Lobo, Margaret J.; Swinton, Marilyn; Pirpiris, Marinis; Molund, Marius; Gichuru, Mark; Glazebrook, Mark; Harrison, Mark; Jenkins, Mark; MacLeod, Mark; de Vries, Mark R.; Butler, Mark S.; Nousiainen, Markku; van ‘t Riet, Martijne; Tynan, Martin C.; Campo, Martin; Eversdijk, Martin G.; Heetveld, Martin J.; Richardson, Martin; Breslin, Mary; Fan, Mary; Edison, Matt; Napierala, Matthew; Knobe, Matthias; Russ, Matthias; Zomar, Mauri; de Brauw, Maurits; Esser, Max; Hurley, Meghan; Peters, Melissa E.; Lorenzo, Melissa; Li, Mengnai; Archdeacon, Michael; Biddulph, Michael; Charlton, Michael R; McDonald, Michael D.; McKee, Michael D.; Dunbar, Michael; Torchia, Michael E.; Gross, Michael; Hewitt, Michael; Holt, Michael; Prayson, Michael J.; Edwards, Michael J R; Beckish, Michael L.; Brennan, Michael L.; Dohm, Michael P.; Kain, Michael S.H.; Vogt, Michelle; Yu, Michelle; Verhofstad, Michiel H J; Segers, Michiel J M; Segers, Michiel J M; Siroen, Michiel P.C.; Reed, Mike; Vicente, Milena R.; Bruijninckx, Milko M.M.; Trivedi, Mittal; Bhandari, Mohit; Moore, Molly M.; Kunz, Monica; Smedsrud, Morten; Palla, Naveen; Jain, Neeraj; Out, Nico J.M.; Simunovic, Nicole; Simunovic, Nicole; Schep, Niels W. L.; Müller, Oliver; Guicherit, Onno R.; Van Waes, Oscar J.F.; Wang, Otis; Doornebosch, Pascal G.; Seuffert, Patricia; Hesketh, Patrick J.; Weinrauch, Patrick; Duffy, Paul; Keller, Paul; Lafferty, Paul M.; Pincus, Paul; Tornetta, Paul; Zalzal, Paul; McKay, Paula; Cole, Peter A.; de Rooij, Peter D.; Hull, Peter; Go, Peter M.N.Y.M.; Patka, Peter; Siska, Peter; Weingarten, Peter; Kregor, Philip; Stahel, Philip; Stull, Philip; Wittich, Philippe; de Rijcke, Piet A.R.; Oprel, Pim; Devereaux, P. J.; Zhou, Qi; Lee Murphy, R.; Alosky, Rachel; Clarkson, Rachel; Moon, Raely; Logishetty, Rajanikanth; Nanda, Rajesh; Sullivan, Raymond J.; Snider, Rebecca G.; Buckley, Richard E.; Iorio, Richard; Farrugia, Richard J.; Jenkinson, Richard; Laughlin, Richard; Groenendijk, Richard P R; Gurich, Richard W.; Worman, Ripley; Silvis, Rob; Haverlag, Robert; Teasdall, Robert J.; Korley, Robert; McCormack, Robert; Probe, Robert; Cantu, Robert V.; Huff, Roger B.; Simmermacher, Rogier K J; Peters, Rolf; Pfeifer, Roman; Liem, Ronald; Wessel, Ronald N.; Verhagen, Ronald; Vuylsteke, Ronald J C L M; Leighton, Ross; McKercher, Ross; Poolman, Rudolf W; Miller, Russell; Bicknell, Ryan; Finnan, Ryan; Khan, Ryan M.; Mehta, Samir; Vang, Sandy; Singh, Sanjay; Anand, Sanjeev; Anderson, Sarah A.; Dawson, Sarah A.; Marston, Scott B.; Porter, Scott E.; Watson, Scott T.; Festen, Sebastiaan; Lieberman, Shane; Puloski, Shannon; Bielby, Shea A.; Sprague, Sheila; Hess, Shelley; MacDonald, Shelley; Evans, Simone; Bzovsky, Sofia; Hasselund, Sondre; Lewis, Sophie; Ugland, Stein; Caminiti, Stephanie; Tanner, Stephanie L.; Zielinski, Stephanie M.; Shepard, Stephanie; Sems, Stephen A.; Walter, Stephen D.; Doig, Stephen; Finley, Stephen H.; Kates, Stephen; Lindenbaum, Stephen; Kingwell, Stephen P.; Csongvay, Steve; Papp, Steve; Buijk, Steven E.; Rhemrev, Steven J.; Hollenbeck, Steven M.; van Gaalen, Steven M.; Yang, Steven; Weinerman, Stuart; Lambert, Sue; Liew, Susan; Meylaerts, Sven A.G.; Blokhuis, Taco J.; de Vries Reilingh, Tammo S.; Lona, Tarjei; Scott, Taryn; Swenson, Teresa K.; Endres, Terrence J.; Axelrod, Terry; van Egmond, Teun; Pace, Thomas B.; Kibsgård, Thomas; Schaller, Thomas M.; Ly, Thuan V.; Miller, Timothy J.; Weber, Timothy; Le, Toan; Oliver, Todd M.; Karsten, Tom M.; Borch, Tor; Hoseth, Tor Magne; Nicolaisen, Tor; Ianssen, Torben; Rutherford, Tori; Nanney, Tracy; Gervais, Trevor; Stone, Trevor; Schrickel, Tyson; Scrabeck, Tyson; Ganguly, Utsav; Naumetz, V.; Frizzell, Valda; Wadey, Veronica; Jones, Vicki; Avram, Victoria; Mishra, Vimlesh; Yadav, Vineet; Arora, Vinod; Tyagi, Vivek; Borsella, Vivian; Willems, W. Jaap; Hoffman, W. H.; Gofton, Wade T.; Lackey, Wesley G.; Ghent, Wesley; Obremskey, William; Oxner, William; Cross, William W.; Murtha, Yvonne M.; Murdoch, Zoe

    2017-01-01

    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we

  15. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    NARCIS (Netherlands)

    Nauth, A. (Aaron); Creek, A.T. (Aaron T.); Zellar, A. (Abby); Lawendy, A.-R. (Abdel-Rahman); Dowrick, A. (Adam); Gupta, A. (Ajay); Dadi, A. (Akhil); A. van Kampen (A.); Yee, A. (Albert); A.C. de Vries (Alexander); de Mol van Otterloo, A. (Alexander); Garibaldi, A. (Alisha); Liew, A. (Allen); McIntyre, A.W. (Allison W.); Prasad, A.S. (Amal Shankar); Romero, A.W. (Amanda W.); Rangan, A. (Amar); Oatt, A. (Amber); Sanghavi, A. (Amir); Foley, A.L. (Amy L.); Karlsten, A. (Anders); Dolenc, A. (Andrea); Bucknill, A. (Andrew); Chia, A. (Andrew); Evans, A. (Andrew); Gong, A. (Andrew); Schmidt, A.H. (Andrew H.); Marcantonio, A.J. (Andrew J.); Jennings, A. (Andrew); Ward, A. (Angela); Khanna, A. (Angshuman); Rai, A. (Anil); Smits, A.B. (Anke B.); Horan, A.D. (Annamarie D.); Brekke, A.C. (Anne Christine); Flynn, A. (Annette); Duraikannan, A. (Aravin); Stødle, A. (Are); van Vugt, A.B. (Arie B.); Luther, A. (Arlene); Zurcher, A.W. (Arthur W.); Jain, A. (Arvind); Amundsen, A. (Asgeir); Moaveni, A. (Ash); Carr, A. (Ashley); Sharma, A. (Ateet); Hill, A.D. (Austin D.); Trommer, A. (Axel); Rai, B.S. (B. Sachidananda); Hileman, B. (Barbara); Schreurs, B. (Bart); Verhoeven, B. (Bart); Barden, B.B. (Benjamin B.); Flatøy, B. (Bernhard); B.I. Cleffken (Berry); Bøe, B. (Berthe); Perey, B. (Bertrand); Hanusch, B.C. (Birgit C.); Weening, B. (Brad); B. Fioole (Bram); Rijbroek, B. (Bram); Crist, B.D. (Brett D.); Halliday, B. (Brett); Peterson, B. (Brett); Mullis, B. (Brian); Richardson, C.G. (C. Glen); Clark, C. (Callum); Sagebien, C.A. (Carlos A.); C. van der Pol (Carmen); Bowler, C. (Carol); Humphrey, C.A. (Catherine A.); Coady, C. (Catherine); Koppert, C.L. (Cees L.); Coles, C. (Chad); Tannoury, C. (Chadi); DePaolo, C.J. (Charles J.); Gayton, C. (Chris); Herriott, C. (Chris); Reeves, C. (Christina); Tieszer, C. (Christina); Dobb, C. (Christine); Anderson, C.G. (Christopher G.); Sage, C. (Claire); Cuento, C. (Claudine); Jones, C.B. (Clifford B.); Bosman, C.H.R. (Coks H.R.); Linehan, C. (Colleen); C.P. van der Hart (Cor P.); Henderson, C. (Corey); Lewis, C.G. (Courtland G.); Davis, C.A. (Craig A.); Donohue, C. (Craig); Mauffrey, C. (Cyril); Sundaresh, D.C. (D. C.); Farrell, D.J. (Dana J.); Whelan, D.B. (Daniel B.); Horwitz, D. (Daniel); Stinner, D. (Daniel); Viskontas, D. (Darius); Roffey, D.M. (Darren M.); Alexander, D. (David); Karges, D.E. (David E.); Hak, D. (David); Johnston, D. (David); Love, D. (David); Wright, D.M. (David M.); Zamorano, D.P. (David P.); Goetz, D.R. (David R.); Sanders, D. (David); Stephen, D. (David); Yen, D. (David); Bardana, D. (Davide); Olakkengil, D.J. (Davy J); Lawson, D. (Deanna); Maddock, D. (Deborah); Sietsema, D.L. (Debra L.); Pourmand, D. (Deeba); D. den Hartog (Dennis); Donegan, D. (Derek); D. Heels-Ansdell (Diane); Nam, D. (Diane); Inman, D. (Dominic); Boyer, D. (Dory); Li, D. (Doug); Gibula, D. (Douglas); Price, D.M. (Dustin M.); Watson, D.J. (Dylan J.); Hammerberg, E.M. (E. Mark); Tan, E.T.C.H. (Edward T.C.H.); E.J.R. de Graaf (Eelco); Vesterhus, E.B. (Elise Berg); Roper, E. (Elizabeth); Edwards, E. (Elton); E.H. Schemitsch (Emil); E.R. Hammacher (Eric); Henderson, E.R. (Eric R.); Whatley, E. (Erica); Torres, E.T. (Erick T.); Vermeulen, E.G.J. (Erik G.J.); Finn, E. (Erin); E.M.M. van Lieshout (Esther); Wai, E.K. (Eugene K.); Bannister, E.R. (Evan R.); Kile, E. (Evelyn); Theunissen, E.B.M. (Evert B.M.); Ritchie, E.D. (Ewan D.); Khan, F. (Farah); Moola, F. (Farhad); Howells, F. (Fiona); F. de Nies (Frank); F.H.W.M. van der Heijden (Frank); de Meulemeester, F.R.A.J. (Frank R.A.J.); F. Frihagen (Frede); Nilsen, F. (Fredrik); Schmidt, G.B. (G. Ben); Albers, G.H.R. (G.H. Robert); Gudger, G.K. (Garland K.); Johnson, G. (Garth); Gruen, G. (Gary); Zohman, G. (Gary); Sharma, G. (Gaurav); Wood, G. (Gavin); G.W.M. Tetteroo (Geert); Hjorthaug, G. (Geir); Jomaas, G. (Geir); Donald, G. (Geoff); Rieser, G.R. (Geoffrey Ryan); Reardon, G. (Gerald); Slobogean, G.P. (Gerard P.); G.R. Roukema (Gert); Visser, G.A. (Gijs A.); Moatshe, G. (Gilbert); Horner, G. (Gillian); Rose, G. (Glynis); Guyatt, G. (Gordon); Chuter, G. (Graham); Etherington, G. (Greg); Rocca, G.J.D. (Gregory J. Della); Ekås, G. (Guri); Dobbin, G. (Gwendolyn); Lemke, H.M. (H. Michael); Curry, H. (Hamish); H. Boxma (Han); Gissel, H. (Hannah); Kreder, H. (Hans); Kuiken, H. (Hans); H.L.F. Brom; Pape, H.-C. (Hans-Christoph); H.M. van der Vis (Harm); Bedi, H. (Harvinder); Vallier, H.A. (Heather A.); Brien, H. (Heather); Silva, H. (Heather); Newman, H. (Heike); H. Viveiros (Helena); van der Hoeven, H. (Henk); Ahn, H. (Henry); Johal, H. (Herman); H. Rijna; Stockmann, H. (Heyn); Josaputra, H.A. (Hong A.); Carlisle, H. (Hope); van der Brand, I. (Igor); I. Dawson (Imro); Tarkin, I. (Ivan); Wong, I. (Ivan); Parr, J.A. (J. Andrew); Trenholm, J.A. (J. Andrew); J.C. Goslings (Carel); Amirault, J.D. (J. David); Broderick, J.S. (J. Scott); Snellen, J.P. (Jaap P.); Zijl, J.A.C. (Jacco A.C.); Ahn, J. (Jaimo); Ficke, J. (James); Irrgang, J. (James); Powell, J. (James); Ringler, J.R. (James R.); Shaer, J. (James); Monica, J.T. (James T.); J. Biert (Jan); Bosma, J. (Jan); Brattgjerd, J.E. (Jan Egil); J.P.M. Frölke (Jan Paul); J.C. Wille (Jan); Rajakumar, J. (Janakiraman); Walker, J.E. (Jane E.); Baker, J.K. (Janell K.); Ertl, J.P. (Janos P.); de Vries, J.P.P.M. (Jean Paul P.M.); Gardeniers, J.W.M. (Jean W.M.); May, J. (Jedediah); Yach, J. (Jeff); Hidy, J.T. (Jennifer T.); Westberg, J.R. (Jerald R.); Hall, J.A. (Jeremy A.); van Mulken, J. (Jeroen); McBeth, J.C. (Jessica Cooper); Hoogendoorn, J. (Jochem); Hoffman, J.M. (Jodi M.); Cherian, J.J. (Joe Joseph); Tanksley, J.A. (John A.); Clarke-Jenssen, J. (John); Adams, J.D. (John D.); Esterhai, J. (John); Tilzey, J.F. (John F.); Murnaghan, J. (John); Ketz, J.P. (John P.); Garfi, J.S. (John S.); Schwappach, J. (John); Gorczyca, J.T. (John T.); Wyrick, J. (John); Rydinge, J. (Jonas); Foret, J.L. (Jonathan L.); Gross, J.M. (Jonathan M.); Keeve, J.P. (Jonathan P.); Meijer, J. (Joost); J.J. Scheepers (Joris J.); Baele, J. (Joseph); O'Neil, J. (Joseph); Cass, J.R. (Joseph R.); Hsu, J.R. (Joseph R.); Dumais, J. (Jules); Lee, J. (Julia); Switzer, J.A. (Julie A.); Agel, J. (Julie); Richards, J.E. (Justin E.); Langan, J.W. (Justin W.); Turckan, K. (Kahn); Pecorella, K. (Kaili); Rai, K. (Kamal); Aurang, K. (Kamran); Shively, K. (Karl); K.J.P. van Wessem; Moon, K. (Karyn); Eke, K. (Kate); Erwin, K. (Katie); Milner, K. (Katrine); K.J. Ponsen (Kees-jan); Mills, K. (Kelli); Apostle, K. (Kelly); Johnston, K. (Kelly); Trask, K. (Kelly); Strohecker, K. (Kent); Stringfellow, K. (Kenya); Kruse, K.K. (Kevin K.); Tetsworth, K. (Kevin); Mitchell, K. (Khalis); Browner, K. (Kieran); Hemlock, K. (Kim); Carcary, K. (Kimberly); Jørgen Haug, K. (Knut); Noble, K. (Krista); Robbins, K. (Kristin); Payton, K. (Krystal); Jeray, K.J. (Kyle J.); Rubino, L.J. (L. Joseph); Nastoff, L.A. (Lauren A.); Leffler, L.C. (Lauren C.); L.P. Stassen (Laurents); O'Malley, L.K. (Lawrence K.); Specht, L.M. (Lawrence M.); L. Thabane (Lehana); Geeraedts, L.M.G. (Leo M.G.); Shell, L.E. (Leslie E.); Anderson, L.K. (Linda K.); Eickhoff, L.S. (Linda S.); Lyle, L. (Lindsey); Pilling, L. (Lindsey); Buckingham, L. (Lisa); Cannada, L.K. (Lisa K.); Wild, L.M. (Lisa M.); Dulaney-Cripe, L. (Liz); L.M.S.J. Poelhekke; Govaert, L. (Lonneke); Ton, L. (Lu); Kottam, L. (Lucksy); L.P.H. Leenen (Luke); Clipper, L. (Lydia); Jackson, L.T. (Lyle T.); Hampton, L. (Lynne); de Waal Malefijt, M.C. (Maarten C.); M.P. Simons; M. van der Elst (Maarten); M.W.G.A. Bronkhorst (Maarten); Bhatia, M. (Mahesh); M.F. Swiontkowski (Marc ); Lobo, M.J. (Margaret J.); Swinton, M. (Marilyn); Pirpiris, M. (Marinis); Molund, M. (Marius); Gichuru, M. (Mark); Glazebrook, M. (Mark); Harrison, M. (Mark); Jenkins, M. (Mark); MacLeod, M. (Mark); M.R. de Vries (Mark); Butler, M.S. (Mark S.); Nousiainen, M. (Markku); van ‘t Riet, M. (Martijne); Tynan, M.C. (Martin C.); Campo, M. (Martin); M.G. Eversdijk (Martin); M.J. Heetveld (Martin); Richardson, M. (Martin); Breslin, M. (Mary); Fan, M. (Mary); Edison, M. (Matt); Napierala, M. (Matthew); Knobe, M. (Matthias); Russ, M. (Matthias); Zomar, M. (Mauri); de Brauw, M. (Maurits); Esser, M. (Max); Hurley, M. (Meghan); Peters, M.E. (Melissa E.); Lorenzo, M. (Melissa); Li, M. (Mengnai); Archdeacon, M. (Michael); Biddulph, M. (Michael); Charlton, M. (Michael); McDonald, M.D. (Michael D.); McKee, M.D. (Michael D.); Dunbar, M. (Michael); Torchia, M.E. (Michael E.); Gross, M. (Michael); Hewitt, M. (Michael); Holt, M. (Michael); Prayson, M.J. (Michael J.); M.J.R. Edwards (Michael); Beckish, M.L. (Michael L.); Brennan, M.L. (Michael L.); Dohm, M.P. (Michael P.); Kain, M.S.H. (Michael S.H.); Vogt, M. (Michelle); Yu, M. (Michelle); M.H.J. Verhofstad (Michiel); Segers, M.J.M. (Michiel J.M.); M.J.M. Segers (Michiel); Siroen, M.P.C. (Michiel P.C.); M.R. Reed (Mike); Vicente, M.R. (Milena R.); M.M.M. Bruijninckx (Milko); Trivedi, M. (Mittal); M. Bhandari (Mohit); Moore, M.M. (Molly M.); Kunz, M. (Monica); Smedsrud, M. (Morten); Palla, N. (Naveen); Jain, N. (Neeraj); Out, N.J.M. (Nico J.M.); Simunovic, N. (Nicole); Simunovic, N. (Nicole); N.W.L. Schep (Niels); Müller, O. (Oliver); Guicherit, O.R. (Onno R.); O.J.F. van Waes (Oscar); Wang, O. (Otis); P. Doornebosch (Pascal); Seuffert, P. (Patricia); Hesketh, P.J. (Patrick J.); Weinrauch, P. (Patrick); Duffy, P. (Paul); Keller, P. (Paul); Lafferty, P.M. (Paul M.); Pincus, P. (Paul); P. Tornetta III (Paul); Zalzal, P. (Paul); McKay, P. (Paula); Cole, P.A. (Peter A.); de Rooij, P.D. (Peter D.); Hull, P. (Peter); Go, P.M.N.Y.M. (Peter M.N.Y.M.); P. Patka (Peter); Siska, P. (Peter); Weingarten, P. (Peter); Kregor, P. (Philip); Stahel, P. (Philip); Stull, P. (Philip); P. Wittich (Philippe); P.A.R. Rijcke (Piet); P.P. Oprel (Pim); Devereaux, P.J. (P. J.); Zhou, Q. (Qi); Lee Murphy, R. (R.); Alosky, R. (Rachel); Clarkson, R. (Rachel); Moon, R. (Raely); Logishetty, R. (Rajanikanth); Nanda, R. (Rajesh); Sullivan, R.J. (Raymond J.); Snider, R.G. (Rebecca G.); Buckley, R.E. (Richard E.); Iorio, R. (Richard); Farrugia, R.J. (Richard J); Jenkinson, R. (Richard); Laughlin, R. (Richard); R.P.R. Groenendijk (Richard); Gurich, R.W. (Richard W.); Worman, R. (Ripley); Silvis, R. (Rob); R. Haverlag (Robert); Teasdall, R.J. (Robert J.); Korley, R. (Robert); McCormack, R. (Robert); Probe, R. (Robert); Cantu, R.V. (Robert V.); Huff, R.B. (Roger B.); R.K.J. Simmermacher; Peters, R. (Rolf); Pfeifer, R. (Roman); Liem, R. (Ronald); Wessel, R.N. (Ronald N.); Verhagen, R. (Ronald); Vuylsteke, R. (Ronald); Leighton, R. (Ross); McKercher, R. (Ross); R.W. Poolman (Rudolf); Miller, R. (Russell); Bicknell, R. (Ryan); Finnan, R. (Ryan); Khan, R.M. (Ryan M.); Mehta, S. (Samir); Vang, S. (Sandy); Singh, S. (Sanjay); Anand, S. (Sanjeev); Anderson, S.A. (Sarah A.); Dawson, S.A. (Sarah A.); Marston, S.B. (Scott B.); Porter, S.E. (Scott E.); Watson, S.T. (Scott T.); S. Festen (Sebastiaan); Lieberman, S. (Shane); Puloski, S. (Shannon); Bielby, S.A. (Shea A.); Sprague, S. (Sheila); Hess, S. (Shelley); MacDonald, S. (Shelley); Evans, S. (Simone); Bzovsky, S. (Sofia); Hasselund, S. (Sondre); Lewis, S. (Sophie); Ugland, S. (Stein); Caminiti, S. (Stephanie); Tanner, S.L. (Stephanie L.); S.M. Zielinski (Stephanie); Shepard, S. (Stephanie); Sems, S.A. (Stephen A.); Walter, S.D. (Stephen D.); Doig, S. (Stephen); Finley, S.H. (Stephen H.); Kates, S. (Stephen); Lindenbaum, S. (Stephen); Kingwell, S.P. (Stephen P.); Csongvay, S. (Steve); Papp, S. (Steve); Buijk, S.E. (Steven E.); S. Rhemrev (Steven); Hollenbeck, S.M. (Steven M.); van Gaalen, S.M. (Steven M.); Yang, S. (Steven); Weinerman, S. (Stuart); Subash, (); Lambert, S. (Sue); Liew, S. (Susan); S.A.G. Meylaerts (Sven); Blokhuis, T.J. (Taco J.); de Vries Reilingh, T.S. (Tammo S.); Lona, T. (Tarjei); Scott, T. (Taryn); Swenson, T.K. (Teresa K.); Endres, T.J. (Terrence J.); Axelrod, T. (Terry); van Egmond, T. (Teun); Pace, T.B. (Thomas B.); Kibsgård, T. (Thomas); Schaller, T.M. (Thomas M.); Ly, T.V. (Thuan V.); Miller, T.J. (Timothy J.); Weber, T. (Timothy); Le, T. (Toan); Oliver, T.M. (Todd M.); T.M. Karsten (Thomas); Borch, T. (Tor); Hoseth, T.M. (Tor Magne); Nicolaisen, T. (Tor); Ianssen, T. (Torben); Rutherford, T. (Tori); Nanney, T. (Tracy); Gervais, T. (Trevor); Stone, T. (Trevor); Schrickel, T. (Tyson); Scrabeck, T. (Tyson); Ganguly, U. (Utsav); Naumetz, V. (V.); Frizzell, V. (Valda); Wadey, V. (Veronica); Jones, V. (Vicki); Avram, V. (Victoria); Mishra, V. (Vimlesh); Yadav, V. (Vineet); Arora, V. (Vinod); Tyagi, V. (Vivek); Borsella, V. (Vivian); W.J. Willems (Jaap); Hoffman, W.H. (W. H.); Gofton, W.T. (Wade T.); Lackey, W.G. (Wesley G.); Ghent, W. (Wesley); Obremskey, W. (William); Oxner, W. (William); Cross, W.W. (William W.); Murtha, Y.M. (Yvonne M.); Murdoch, Z. (Zoe)

    2017-01-01

    textabstractBackground Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled

  16. Monteggia fracture dislocation equivalents - analysis of eighteen cases treated by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Singh Ajay Pal

    2012-02-01

    Full Text Available 【Abstract】 Objective: Monteggia fracture dislocation equivalent, though already described by Bado, is still an unclassified entity. We aimed to retrospectively analyze 18 cases of Monteggia variants and discuss the injury mechanisms, management, and outcome along with a review of the literature. Methods: A retrospective record of Monteggia fracture dislocation (2003-2008 was reviewed from medical record department of our institute. Classic Monteggia fracture dislocation, children below 12 years or adults over 50 years, as well as open grade II & III cases were excluded from this study. Monteggia variant inclusion criteria included fracture of the proximal ulna together with a fracture of the radial head or neck and skeletal maturity. Totally 26 patients were identified with Monteggia variants and 18 were available for follow-up, including 11 males and 7 females with the mean age of 35 years. The ulna fracture was treated by compression plating along with tension band wiring. Radial head/neck was reconstructed in 12 patients while excised in 6 patients. Results: Follow-up ranged from 1-4 years, mean 2.6 years. Patients were assessed clinicoradiologically. Mayo Elbow Performance Score was employed to assess the outcomes. At final follow-up, the results were excellent in 10 patients, good in 4, fair in 2 and poor in 2. Mean range of motion of the elbow was 20°, 116°, 50° and 55° for extension, flexion, pronation and supination, respectively. Two patients had complications in the form of heterotopic ossification and stiffness of the elbow. One nonunion ulna, primarily treated by tension band wiring, was managed by refixation with locking reconstruction plate and bone grafting. Bone grafting was only required in this patient for nonunion. Another patient had implants removed on his request. The results in our series closely correlated with extent of intraarticular damage, coronoid fracture and comminuted fractures. Conclusions: Monteggia

  17. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    Science.gov (United States)

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  18. Isotopes in biological dinitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-01

    Nineteen papers were presented at the conference. Some topics discussed are as follows: biochemistry and genetics of dinitrogen fixation; genetics of the Rhizobium-legume symbiosis and of the nitrogen-fixing bacteria; studies on nonsymbiotic dinitrogen fixation in grass-bacteria associations and blue--green algae; use of /sup 15/N and /sup 13/N for the assay of dinitrogen fixation; effects of management practices on dinitrogen fixation; economy of C and N in nitrogen-fixing legumes; and survey of international and national programs on dinitrogen fixation. (HLW)

  19. The use of biochemical markers of bone remodeling in multiple myeloma: a report of the International Myeloma Working Group

    DEFF Research Database (Denmark)

    Terpos, E; Dimopoulos, M A; Sezer, O

    2010-01-01

    progression and overall survival. Bone markers have also been used for the early diagnosis of bone lesions. This International Myeloma Working Group report summarizes the existing data for the role of bone markers in assessing the extent of MM bone disease and in monitoring bone turnover during anti...

  20. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    International Nuclear Information System (INIS)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E.

    1992-01-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author)

  1. The Relationship of the Facial Nerve to the Condylar Process: A Cadaveric Study with Implications for Open Reduction Internal Fixation

    Directory of Open Access Journals (Sweden)

    H. P. Barham

    2015-01-01

    Full Text Available Introduction. The mandibular condyle is the most common site of mandibular fracture. Surgical treatment of condylar fractures by open reduction and internal fixation (ORIF demands direct visualization of the fracture. This project aimed to investigate the anatomic relationship of the tragus to the facial nerve and condylar process. Materials and Methods. Twelve fresh hemicadavers heads were used. An extended retromandibular/preauricular approach was utilized, with the incision being based parallel to the posterior edge of the ramus. Measurements were obtained from the tragus to the facial nerve and condylar process. Results. The temporozygomatic division of the facial nerve was encountered during each approach, crossing the mandible at the condylar neck. The mean tissue depth separating the facial nerve from the condylar neck was 5.5 mm (range: 3.5 mm–7 mm, SD 1.2 mm. The upper division of the facial nerve crossed the posterior border of the condylar process on average 2.31 cm (SD 0.10 cm anterior to the tragus. Conclusions. This study suggests that the temporozygomatic division of the facial nerve will be encountered in most approaches to the condylar process. As visualization of the relationship of the facial nerve to condyle is often limited, recognition that, on average, 5.5 mm of tissue separates condylar process from nerve should help reduce the incidence of facial nerve injury during this procedure.

  2. Lower reoperation rate for cemented hemiarthroplasty than for uncemented hemiarthroplasty and internal fixation following femoral neck fracture

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Overgaard, Søren; Lauritsen, Jens

    2013-01-01

    a reoperation rate (RR) of 5% and was used as reference in the Cox regression analysis, which showed significantly higher hazard ratios (HRs) for IF (HR = 3.8, 95% CI: 1.9-7.5; RR = 18%), uncemented HA (HR = 2.2, CI: 1.1-4.5; RR = 11%) and uncemented hydroxyapatite-coated HA (HR = 3.6, CI: 1.8-7.4; RR = 16...... treated with either internal fixation (IF), cemented HA, or uncemented HA (with or without hydroxyapatite coating), after 12-19 years of follow-up. Methods 4 hospitals with clearly defined guidelines for the treatment of 75+ year-old patients with a displaced femoral neck fracture were included. Cohort 1...... an uncemented hydroxyapatite-coated Furlong HA. Data were retrieved from patient files, from the region-based patient administrative system, and from the National Registry of Patients at the end of 2010. We performed survival analysis with adjustment for comorbidity, age, and sex. Results Cemented HA had...

  3. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    Energy Technology Data Exchange (ETDEWEB)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E. (Ankara Social Security Hospital (Turkey))

    1992-08-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author).

  4. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    Science.gov (United States)

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  5. Biomechanical in vitro evaluation of three stable internal fixation techniques used in sagittal osteotomy of the mandibular ramus: a study in sheep mandibles

    Directory of Open Access Journals (Sweden)

    Leandro Benetti de Olivera

    2012-08-01

    Full Text Available Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR is the most common, allowing a great range of movements and stable internal fixation (SIF, therefore eliminating the need of maxillomandibular block in the postoperative period. OBJECTIVES: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. MATERIAL AND METHODS: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group. In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group. In group III, fixation was performed with two 4-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group. All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. RESULTS: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. CONCLUSION: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

  6. A Modified Technique of Fixation for Proximal Femoral Valgus Osteotomy in Abnormal Bone: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Logheswaren S

    2017-07-01

    Full Text Available The ideal size of intramedullary device to fix corrective osteotomy of proximal femur in abnormal bone in children and small patients may not be easily available. We report the successful use of Rush rod in combination with multiple Kirschner wires to fix the corrective osteotomy of coxa vara and shepherd crook deformity in two patients with osteogenesis imperfecta and fibrous dysplasia. The union was achieved on time, neck shaft angle and rotation were maintained.

  7. Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) protocol: a pragmatic multi-centre randomised controlled trial of cast treatment versus surgical fixation for the treatment of bi-cortical, minimally displaced fractures of the scaphoid waist in adults.

    Science.gov (United States)

    Dias, Joseph; Brealey, Stephen; Choudhary, Surabhi; Cook, Liz; Costa, Matthew; Fairhurst, Caroline; Hewitt, Catherine; Hodgson, Stephen; Jefferson, Laura; Jeyapalan, Kanagaratnam; Keding, Ada; Leighton, Paul; Rangan, Amar; Richardson, Gerry; Rothery, Claire; Taub, Nicholas; Thompson, John; Torgerson, David

    2016-06-04

    A scaphoid fracture is the most common type of carpal fracture affecting young active people. The optimal management of this fracture is uncertain. When treated with a cast, 88 to 90 % of these fractures unite; however, for the remaining 10-12 % the non-union almost invariably leads to arthritis. The alternative is surgery to fix the scaphoid with a screw at the outset. We will conduct a randomised controlled trial (RCT) of 438 adult patients with a "clear" and "bicortical" scaphoid waist fracture on plain radiographs to evaluate the clinical effectiveness and cost-effectiveness of plaster cast treatment (with fixation of those that fail to unite) versus early surgical fixation. The plaster cast treatment will be immobilisation in a below elbow cast for 6 to 10 weeks followed by mobilisation. If non-union is confirmed on plain radiographs and/or Computerised Tomogram at 6 to 12 weeks, then urgent surgical fixation will be performed. This is being compared with immediate surgical fixation with surgeons using their preferred technique and implant. These treatments will be undertaken in trauma units across the United Kingdom. The primary outcome and end-point will be the Patient Rated Wrist Evaluation (a patient self-reported assessment of wrist pain and function) at 52 weeks and also measured at 6, 12, 26 weeks and 5 years. Secondary outcomes include an assessment of radiological union of the fracture; quality of life; recovery of wrist range and strength; and complications. We will also qualitatively investigate patient experiences of their treatment. Scaphoid fractures are an important public health problem as they predominantly affect young active individuals in the more productive working years of their lives. Non-union, if untreated, can lead to arthritis which can disable patients at a very young age. There is a rapidly increasing trend for immediate surgical fixation of these fractures but there is insufficient evidence from existing RCTs to support

  8. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  9. Miniplate fixation of Le Fort I osteotomies.

    Science.gov (United States)

    Rosen, H M

    1986-12-01

    The use of rigid, internal, three-dimensional fixation using vitallium bone plates in 28 consecutive Le Fort I osteotomies is presented. A minimum follow-up period of 6 months was required for inclusion in this patient group. Maxillary movements included advancements (17), intrusions (9), lengthenings (5), and retrusions (2). The majority of maxillae were moved in more than one plane of space. Technical details, complications, and relapse potential are discussed. Advantages of rigid plate fixation include marked reductions in the length of intermaxillary fixation with light training elastics only. Immediate postoperative airway problems are thereby eliminated. Six months of follow-up would appear to indicate a low potential for osseous relapse when compared to wire osteosynthesis, regardless of the direction of maxillary movement. The major disadvantage is the decreased ability of postoperative orthodontics to move dento-osseous segments if skeletal occlusal disharmony persists postoperatively. For this reason, close attention to preoperative planning and operative technique is critical for the success of this fixation method.

  10. Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures in Chinese Han population: a meta-analysis.

    Science.gov (United States)

    Xu, Jiaming; Zhang, Changqing

    2014-04-11

    This meta-analysis aimed to compare the therapeutic effect of mini-plate versus Kirschner wire (K-wire) internal fixation on the treatment of metacarpal and phalangeal fractures among Chinese Han population. Databases of China National Knowledge Infrastructure (CNKI), Wanfang, Chinese VIP, PubMed, and Embase were retrieved for studies on mini-plate (case group) versus K-wire (control group) internal fixation for the treatment of metacarpal and phalangeal fractures among Chinese Han population. The odds ratio (OR) and standardized mean difference (SMD) at 95% confidence interval (CI) were used for estimating the effects of dichotomous data and continuous data, respectively. All statistical analyses were performed by Review Manager 5.2 software. A total of 18 studies involving 1,375 metacarpal or phalangeal fracture patients (709 cases and 666 controls) were included in the meta-analysis. There were significant differences in fracture healing time (SMD = -1.28; 95% CI: -1.81, -0.76), postoperative infection rate (OR = 0.25; 95% CI: 0.16, 0.39), complication incidence (OR = 0.24; 95% CI: 0.15, 0.38), and surgery time (SMD = 1.57; 95% CI: 0.76, 2.37) between the case and the control group, while no significant difference was found in hospital stays between these two groups (SMD = 0.43; 95% CI: -0.34, 1.20; P = 0.27). For the treatment of metacarpal or phalangeal fracture among Chinese Han population, mini-plate has advantages of shorter healing time and lower infection rate and complication incidence compared with K-wire internal fixation, while a longer surgery time than K-wire. In conclusion, mini-plate is prior than K-wire internal fixation for the treatment of metacarpal or phalangeal fracture among Chinese Han population.

  11. Implant failure in osteosynthesis of fractures of long bones ...

    African Journals Online (AJOL)

    Patients who had open operative treatment of fractures of long bones were reviewed retrospectively to identify the incidence of and risk factors for implant failure. One hundred and five patients had open reduction and internal fixation of 117 fractures of long bones, out of which four patients suffered implant failure.

  12. Evaluation of bone and disc configuration in TMJ internal derangement

    International Nuclear Information System (INIS)

    Park, Cheol Woo; Hwang, Eui Hwan; Lee, Sang Rae

    2001-01-01

    To investigate bone and disc configuration on MR images in internal derangement related to age. MR images of 150 TMJs in 107 patients were analyzed to determine the morphologic changes. Two groups were distinguished to be correlated with age. Group 1 consisted of TMJs that were diagnosed as having anterior disc displacement with reduction (ADDwR), and Group 2 consisted of TMJs that were diagnosed as having anterior disc displacement without reduction (ADDwR). We assessed the configuration of the articular disc, degree of anterior disc displacement, and osseous changes of TMJs. The third decade (83 of 150 joints) was most frequent in this study. In the ADDwR group biconcave disc was most frequent at all ages except fifth decade, but in the ADDwoR group deformed discs was most frequent at third and forth decades. In the ADDwR group slightly displaced discs was most frequent at all ages, but in the ADDwoR group severely displaced discs was most frequent at second decade, and the degree of disc displacement was increased with aging over 30 years of age. TM joints showed osseous changes in 17% of the ADDwR group, and in 30% of the ADDwoR group. MR findings of osseous changes of the TMJ were not found to be significantly correlated with age. The prevalence of deformation of disc, displacement of disc, and osseous changes of TMJ was higher in the ADDwoR group than in the ADDwR group. MR findings of disc configuration and degree of disc displacement were found to be correlated with age

  13. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  14. [Case-control study on measurement of coracoclavicular and acromioclavicular ligament injuries during internal fixation operation for the treatment of fresh acromioclavicular joint dislocation of Tossy type III].

    Science.gov (United States)

    Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang

    2014-01-01

    To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged

  15. Short-Term Therapeutic Efficacy of the Isobar TTL Dynamic Internal Fixation System for the Treatment of Lumbar Degenerative Disc Diseases.

    Science.gov (United States)

    Qian, Jiale; Bao, Zhaohua; Li, Xuefeng; Zou, Jun; Yang, Huilin

    2016-07-01

    At present, posterior interbody fusion surgery with pedicle internal fixation is the gold standard for the treatment of lumbar degenerative disc diseases. However, an increasing number of studies have shown that because fused lumbar vertebrae lose their physiological activity, the compensatory range of motion (ROM) of the adjacent levels increases. To address this issue, dynamic internal fixation systems have been developed. Our goal was to investigate the short-term therapeutic efficacy of the Isobar TTL dynamic internal fixation system for the treatment of lumbar degenerative disc diseases and its effect on the ROM of the surgical segments. Retrospective Evaluation. Tertiary hospital setting in China. Twenty-four lumbar degenerative disc disease patients who underwent posterior lumbar decompression and single-segment Isobar TTL dynamic internal fixation at our hospital between January 2013 and July 2014 were retrospectively analyzed. The preoperative and one month, 3 month, and 12 month postoperative visual analog scale (VAS) pain scores, Japanese Orthopedic Association (JOA) scores, and Oswestry Disability Index (ODI) scores were observed and recorded to assess the clinical therapeutic effect; the lumbar ROM was measured preoperatively and at the last follow-up to evaluate the preservation of functional movement in the dynamically stabilized segment. All patients underwent the operation successfully without complications during hospitalization and were followed for 12 to 27 months, with an average of 18 months. The patients' preoperative and one month, 3 month, and 12 month postoperative VAS scores were 6.42 ± 0.72, 1.71 ± 0.86, 1.38 ± 0.65, and 1.37 ± 0.58, respectively, and their JOA scores were 9.54 ± 1.89, 21.21 ± 1.98, 22.50 ± 1.47, and 23.46 ± 1.32, respectively. The preoperative ODI score was 42.04 ± 2.63; the one month, 3 month, and 12 month postoperative ODI scores were 22.79 ± 1.61, 18.63 ± 1.61, and 15.08 ± 1.21, respectively. These

  16. Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod

    Directory of Open Access Journals (Sweden)

    Mahmoud A El-Rosasy

    2012-01-01

    . Conclusion: The proposed technique is effective in treating humeral nonunion especially in the presence of osteoporosis and short bone segments. The inclusion of intramedullary rod as internal splint improves stability of fixation and prevents refracture after fixator removal.

  17. Accelerated rehabilitation compared with a standard protocol after distal radial fractures treated with volar open reduction and internal fixation: a prospective, randomized, controlled study.

    Science.gov (United States)

    Brehmer, Jess L; Husband, Jeffrey B

    2014-10-01

    There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation

  18. Management strategy for unicameral bone cyst.

    Science.gov (United States)

    Chuo, Chin-Yi; Fu, Yin-Chih; Chien, Song-Hsiung; Lin, Gau-Tyan; Wang, Gwo-Jaw

    2003-06-01

    The management of a unicameral bone cyst varies from percutaneous needle biopsy, aspiration, and local injection of steroid, autogenous bone marrow, or demineralized bone matrix to the more invasive surgical procedures of conventional curettage and grafting (with autogenous or allogenous bone) or subtotal resection with bone grafting. The best treatment for a unicameral bone cyst is yet to be identified. Better understanding of the pathology will change the concept of management. The aim of treatment is to prevent pathologic fracture, to promote cyst healing, and to avoid cyst recurrence and re-fracture. We retrospectively reviewed 17 cases of unicameral bone cysts (12 in the humerus, 3 in the femur, 2 in the fibula) managed by conservative observation, curettage and bone grafting with open reduction and internal fixation, or continuous decompression and drainage with a cannulated screw. We suggest percutaneous cannulated screw insertion to promote cyst healing and prevent pathologic fracture. We devised a protocol for the management of unicameral bone cysts.

  19. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Science.gov (United States)

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  20. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2016-02-01

    Full Text Available More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

  1. Influence of bone metastases in the red marrow 131INa internal dosimetry

    International Nuclear Information System (INIS)

    Llina Fuentes, C.S.; Cabrejas, M.I.; Cabrejas, R.

    2008-01-01

    other regions and that bone metastasis can increase significantly (23% in this study) the red marrow absorbed dose. Therefore, it is actually important to consider bone metastases in internal dosimetry formalism for DTC patients. In addition, bone marrow absorbed dose calculated with the developed formalism is consistent with the results obtained with biological dosimetry (Fluorescence In Situ Hybridization and Conventional Cytogenetic). (author)

  2. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    Science.gov (United States)

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  3. [Internal fixation with one-hole microplate for the treatment of collateral ligament injuries of the metacarpophalangeal joint of the thumb combined with fracture].

    Science.gov (United States)

    Wang, Xi-Xun; Sun, De-Tao; Chen, Xu-Hui; Li, Jun; Cui, Yan; Hu, Ji-Chao; Shu, Zheng-Hua; He, Jian; Ding, Chao-Qi; Chen, Bo

    2015-03-01

    To study clinical effects of one-hole microplate internal fixation for the treatment of collateral ligament injuries of the metacarpophalangeal joint of the thumb combined with fracture. Twenty-two patients (16 males, 6 females) with collateral ligament injuries of the metacarpophalangeal joint of the thumb combined fracture were treated with one-hole microplate internal fixation. The age of the patients ranged from 18 to 53 years old with a mean age of 28.5 years old. The duration from injury to surgery ranged from 2 hours to 2 months, and the mean time was 6 days. All the patients had collateral ligament injuries combined with fracture of the metacarpophalangeal joint of the thumb. Thirteen patients had injuries in the right hand and 9 patients had injuries in the left hand. There were 18 cases of closed wound and 4 cases of open wound. Eighteen patients had fresh injuries ( 2 weeks). Sixteen patients had injuries in the ulnar collateral ligament of the thumb combined with fracture, 6 patients had radial collateral ligament injuries of the thumb combined with fracture, 4 cases of which were complicated with injuries of abductor pollicis brevis and the end of the flexor pollicis brevis tender. The size of the avulsed fragment was about 3.0 mm x 4.0 mm to 6.0 mm x 7.0 mm. The incisions of 22 patients healed by first intention. The follow-up periods ranged from 6 months to 5 years old,with an average of 2.5 years old. The thumb function was evaluated by Saetta and other evaluation criteria, and 20 patients got an excellent result and 2 good. The application of one-hole microplate internal fixation in treating collateral ligament injuries with fracture of the metacarpophalangeal joint of the thumb is an effective method.

  4. A PROSPECTIVE STUDY ON FUNCTIONAL OUTCOME OF HUMERUS SHAFT FRACTURES TREATED WITH OPEN REDUCTION AND INTERNAL FIXATION WITH DYNAMIC COMPRESSION PLATE AND SCREWS

    Directory of Open Access Journals (Sweden)

    Vidyadhar S. Donimath

    2017-12-01

    Full Text Available BACKGROUND Fracture of the humerus shaft accounts to 3% to 5% of all fractures. Majority of the fractures are unstable due to distraction force of the gravity in the upper limb and strong muscle contraction leading to displacement. Internal fixation and early mobilisation is more stressed on than splinting and prolonged immobilisation to allow earlier mobilisation and rapid return to work. The aim of the study was to study the union rates and the functional outcome and complications associated with shaft humerus fractures in KIMS Hospital. MATERIALS AND METHODS A prospective study which was carried out from October 2015 to September 2017 in Karnataka Institute of Medical Sciences, Hubballi, Karnataka State, India. In this study period, 25 cases of fracture shaft of the humerus were treated by open reduction and internal fixation using DCP. Skeletally mature patients with fresh humerus diaphysis fractures were included in the study. Pathological fractures and Tscherne grade 2 and above, Gustilo Anderson type2 and above were excluded from the study. RESULTS In our series of 25 cases, there were 21 men and 4 women with average age of 42.5 years. Sixteen (64% cases were due to RTA and with predominance of right side. Transverse fractures were most common that is 15 (60% patients. Eleven (31% cases were having associated injuries. 92% of the fractures united with good to excellent outcome. There were 2 (8% cases of non-union due to infection and comminution. CONCLUSION Open reduction and internal fixation with dynamic compression plate is still the standard treatment of choice for fracture shaft of humerus achieving excellent to good functional outcome.

  5. Features of Three- and Four-Part Proximal Humeral Fractures and Outcome of Internal Fixation Using the Philos® Locking Plate

    Directory of Open Access Journals (Sweden)

    Ali Sadighi

    2017-03-01

    Full Text Available Background: Proximal humeral fractures are among common types of fractures and remain a challenging issue for surgical management. This study aimed to assess the clinical outcomes and complication rates of three- vs. four-part proximal humeral fractures, treated with internal fixation using the Philos® plate. Material and Methods: In this cohort study, a total of 30 consecutive patients with three-part or four-part proximal humeral fractures based on the Neer classification were included. Surgical treatment was performed with open reduction and internal fixation using the Philos® plate. The constant score was evaluated 6 months later in follow-up. The P<0.05 was considered significant. Results: Four-part fractures were mainly caused by trauma from above, while insults of opposite direction were responsible for more than half of 3 part fractures (P=0.01. Open fractures were only observed in patients with a four-part fracture (P=0.018. No significant differences were noticed regarding gender, cause, and side of the fracture. The presence of other fractures, fracture of the implant, reduction loss, avascular necrosis (AVN of humerus head, rotator cuff injury, and revision surgery were significantly higher in patients with four-part fractures. The mean constant score was 81.40±11.61 and 65.09±16.09 for three-part and four-part fractures, respectively (P=0.006. Conclusion: Open reduction and internal fixation with Philos® plate yield acceptable results in both types of fractures, however, the prognosis of this intervention is poorer four-part fractures.

  6. Correlations of External Landmarks With Internal Structures of the Temporal Bone.

    Science.gov (United States)

    Piromchai, Patorn; Wijewickrema, Sudanthi; Smeds, Henrik; Kennedy, Gregor; O'Leary, Stephen

    2015-09-01

    The internal anatomy of a temporal bone could be inferred from external landmarks. Mastoid surgery is an important skill that ENT surgeons need to acquire. Surgeons commonly use CT scans as a guide to understanding anatomical variations before surgery. Conversely, in cases where CT scans are not available, or in the temporal bone laboratory where residents are usually not provided with CT scans, it would be beneficial if the internal anatomy of a temporal bone could be inferred from external landmarks. We explored correlations between internal anatomical variations and metrics established to quantify the position of external landmarks that are commonly exposed in the operating room, or the temporal bone laboratory, before commencement of drilling. Mathematical models were developed to predict internal anatomy based on external structures. From an operating room view, the distances between the following external landmarks were observed to have statistically significant correlations with the internal anatomy of a temporal bone: temporal line, external auditory canal, mastoid tip, occipitomastoid suture, and Henle's spine. These structures can be used to infer a low lying dura mater (p = 0.002), an anteriorly located sigmoid sinus (p = 0.006), and a more lateral course of the facial nerve (p external landmarks. The distances between these two landmarks and the operating view external structures were able to further infer the laterality of the facial nerve (p internal structures with a high level of accuracy: the distance from the sigmoid sinus to the posterior external auditory canal (p external landmarks found on the temporal bone. These relationships could be used as a guideline to predict challenges during drilling and choosing appropriate temporal bones for dissection.

  7. Allogenic bone rods with freeze drying and gamma rays irradiation for treatment of fracture

    International Nuclear Information System (INIS)

    Zhou Zhenbin

    1999-01-01

    Opened reduction and internal fixation are the usual treatment of fracture, but both methods need a second operation for removal implants. The benefits of the bone rods are that they can avoid the removement of internal fixation and will be absorbed spontaneously. The bone rods are made of allogeneic compact bones with freeze-drying and gamma rays irradiation supplied by Shanxi Provincial Tissue Bank. The purpose of this study is to evaluate allograft reaction, the stability of the internal fixation, osteoinduction in the treatment of fracture using allogeneic bone rods with freeze drying and gamma rays irradiation. From May 1997 to May 1998, fourteen cases (male 12, female 2) of treatment were reviewed. The mean age was 37.3 (21-5 1). There were 3 medial malleolus fractures, 7 tibia and fibula fractures, 1 ulna and radius fracture, 1 lateral condyle of humerus fracture. The clinical results were satisfactory. Because the strength of the bone rods are weaker than that of screws, the bone rods are only indicated in the fixation of cancellous bones fracture and unloaded bone fracture. It can be used as a supplementary fixation of loaded bone. It is not indicated for fixation of comminuted fracture. More than two bone rods may be used in the fixation of fracture in order to get stability of the fracture and decrease stress between rods which will prevent the break of the bone rods. Allogeneic bone rods with freeze-drying and gamma rays irradiation can be used as implants of non-immunogenicity. There are no allograft reactions in all cases (including fever, leukocytosis, exudation or swelling in the wound). Although plenty of experimental studies have showed that freeze drying with gamma rays irradiation (below 50 KGy) would not destroy BMP of bone allograft, but there is no osteoinduction in our cases. The healing of a fracture and bridging external callus are similar as other operations. This new technique may have the following advantages compare with the screws: 1

  8. [Staple fixation for the treatment of hamate metacarpal joint injury].

    Science.gov (United States)

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  9. Biomechanical study of prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.

    Science.gov (United States)

    Avery, C M E; Best, A; Patterson, P; Rolton, J; Ponter, A R S

    2007-09-01

    This study investigated the strengthening effect of different types of plate and position after osteotomy of the sheep tibia, which is a model for the radial osteocutaneous donor site. Fifty matched pairs of adult sheep tibias were tested in torsion and four-point bending. Firstly, the weakening effect of an osteotomy was compared with the intact bone. Then pairs of bones with an osteotomy were compared with and without reinforcement with different types of 3.5mm plate. The plate was placed in either the anterior (over the defect) or posterior (on the intact cortex) position. In torsion the mean strength of the intact bone was 45% greater than after osteotomy (P=0.02). The reinforced bone was on average 61% stronger than the unreinforced bone (Pbone was 188% greater than after osteotomy (P=0.02). The reinforced bone was on average 184% stronger then the unreinforced bone (P<0.001). The tibia was able to withstand much greater loads in bending. The dynamic compression plate was the strongest reinforcement in both torsion and bending. The position of the plate did not alter the strengthening effect in torsion but the posterior position resisted greater bending loads (P=0.01). This may not be relevant in clinical practice as the radius is likely to fracture first as a result of lower torsional forces.

  10. Fixation compliance in a mouse osteotomy model induces two different processes of bone healing but does not lead to delayed union

    NARCIS (Netherlands)

    Gröngröft, I.; Heil, P.H.; Matthys, R.; Lezuo, P.; Tami, A.E.; Perren, S.; Montavon, P.M.; Ito, K.

    2009-01-01

    Delayed unions are a problematic complication of fracture healing whose pathophysiology is not well understood. Advanced molecular biology methods available with mice would be advantageous for investigation. In humans, decreased fixation rigidity and poor reduction are generally associated with

  11. Strain-stress analysis of lower limb with applied fixator

    Directory of Open Access Journals (Sweden)

    Mrázek M.

    2010-07-01

    Full Text Available This paper compares physiological state of tibia before and after application of an external fixator. The fixator systems’ models but also model of tibia are loaded in the direction of body axis. The paper is focused on the examination of differences in stiffness before and after the application of fixation. Two types of axial external fixators are compared. Both fixators differ in their construction. The first fixator is two-frame and fixation rods are used for fixing the bone tissue (variant I. The second one is fixed into tibia with screws (variant II. We have found out that the two-frame external fixator has much bigger stiffness during limb fixation than the fixator with one body. Much higher deformations compared to physiological state of tibia occur in the variant II.

  12. Relationship between screw sagittal angle and stress on endplate of adjacent segments after anterior cervical corpectomy and fusion with internal fixation: a Chinese finite element study.

    Science.gov (United States)

    Zhang, Yu; Tang, Yibo; Shen, Hongxing

    2017-12-01

    In order to reduce the incidence of adjacent segment disease (ASD), the current study was designed to establish Chinese finite element models of normal 3rd~7th cervical vertebrae (C3-C7) and anterior cervical corpectomy and fusion (ACCF) with internal fixation , and analyze the influence of screw sagittal angle (SSA) on stress on endplate of adjacent cervical segments. Mimics 8.1 and Abaqus/CAE 6.10 softwares were adopted to establish finite element models. For C4 superior endplate and C6 inferior endplate, their anterior areas had the maximum stress in anteflexion position, and their posterior areas had the maximum stress in posterior extension position. As SSA increased, the stress reduced. With an increase of 10° in SSA, the stress on anterior areas of C4 superior endplate and C6 inferior endplate reduced by 12.67% and 7.99% in anteflexion position, respectively. With an increase of 10° in SSA, the stress on posterior areas of C4 superior endplate and C6 inferior endplate reduced by 9.68% and 10.22% in posterior extension position, respectively. The current study established Chinese finite element models of normal C3-C7 and ACCF with internal fixation , and demonstrated that as SSA increased, the stress on endplate of adjacent cervical segments decreased. In clinical surgery, increased SSA is able to play important role in protecting the adjacent cervical segments and reducing the incidence of ASD.

  13. Osseous union in cases of nonunion in long bones treated by ...

    African Journals Online (AJOL)

    To determine the incidence of osseous union in cases of nonunion of long bones managed by open reduction and compression plating. : Between November, 2003 and June, 2005, 53 patients with nonunion of long bones were treated by open reduction and internal fixation and followed up. The follow up period for each ...

  14. Bone density and anisotropy affect periprosthetic cement and bone stresses after anatomical glenoid replacement: A micro finite element analysis.

    Science.gov (United States)

    Chevalier, Yan; Santos, Inês; Müller, Peter E; Pietschmann, Matthias F

    2016-06-14

    Glenoid loosening is still a main complication for shoulder arthroplasty. We hypothesize that cement and bone stresses potentially leading to fixation failure are related not only to glenohumeral conformity, fixation design or eccentric loading, but also to bone volume fraction, cortical thickness and degree of anisotropy in the glenoid. In this study, periprosthetic bone and cement stresses were computed with micro finite element models of the replaced glenoid depicting realistic bone microstructure. These models were used to quantify potential effects of bone microstructural parameters under loading conditions simulating different levels of glenohumeral conformity and eccentric loading simulating glenohumeral instability. Results show that peak cement stresses were achieved near the cement-bone interface in all loading schemes. Higher stresses within trabecular bone tissue and cement mantle were obtained within specimens of lower bone volume fraction and in regions of low anisotropy, increasing with decreasing glenohumeral conformity and reaching their maxima below the keeled design when the load is shifted superiorly. Our analyses confirm the combined influences of eccentric load shifts with reduced bone volume fraction and anisotropy on increasing periprosthetic stresses. They finally suggest that improving fixation of glenoid replacements must reduce internal cement and bone tissue stresses, in particular in glenoids of low bone density and heterogeneity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Comparison of Marginal Bone Loss Between Implants with Internal and External Connections: A Systematic Review.

    Science.gov (United States)

    Palacios-Garzón, Natalia; Mauri-Obradors, Elisabeth; Roselló-LLabrés, Xavier; Estrugo-Devesa, Albert; Jané-Salas, Enric; López-López, José

    The objective of this systematic review was to compare the loss of marginal bone between implants with internal and external connections by analyzing results reported in studies published after 2010. A literature search in MEDLINE with the keywords "dental implant connections, external internal implant connection, bone loss implant designs, internal and external connection implant studies in humans" was conducted. Clinical trials on human beings, comparing both connections and published in English, from 2010 to 2016 were selected. Their methodologic quality was assessed using the Jadad scale. From the initial search, 415 articles were obtained; 32 were chosen as potentially relevant based on their titles and abstracts. Among them, only 10 finally met the inclusion criteria. A total of 1,523 patients with 3,965 implants were analyzed. Six out of 10 studies observed that internal connections showed significantly less bone loss compared with external connections. The remaining four articles did not find statistically significant differences between the two connections. According to this systematic review and considering its limitation due to the degree of heterogeneity between the included studies, both internal and external connections present high survival rates. To assess whether marginal bone loss differs significantly between the two connections, more homogenous clinical studies are needed with identical implant characteristics, larger samples, and longer follow-up periods. Studies included in this review and characterized by long-term follow-ups showed that the external connection is a reliable connection on a long-term basis.

  16. Internal fixation of mandibular angle fractures using one miniplate in Greek children: a 5-year retrospective study.

    Science.gov (United States)

    Iatrou, Ioannis; Theologie-Lygidakis, Nadia; Tzermpos, Fotios; Kamperos, Georgios

    2015-01-01

    Treatment modalities of mandibular angle fractures (MAFs) have been analyzed in several studies mainly referring to adult populations. The aim of this study was to retrospectively present and discuss our experience and literature findings regarding the treatment of MAFs in children. Data were retrieved from the files of the Oral and Maxillofacial department, at the Children's Hospital ''P. & A. Kyriakou'' of Athens, during a 5 years period (2009-2013). Demographic features, treatment methods, outcome and follow-up of all patients with mandibular angle fractures were recorded. 6 boys, 5-14 years old (mean age 10 years), were included in the study. They were all treated intraorally with open reduction and fixation via one monocortical titanium plate osteosynthesis at the external oblique line of the mandible, followed by 1 week of intermaxillary fixation (IMF). Plates were removed 3-12 months post-operatively. Follow-up period ranged from 12 to 18 months (mean 14.7 months). All fractures healed uneventfully and the patients tolerated well both the operation and the post-operative period. Osteosynthesis via intraoral approach combined with short duration IMF is adequate in treating MAFs in children. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Stress Fractures of Tibia Treated with Ilizarov External Fixator.

    Science.gov (United States)

    Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł

    2016-08-30

    Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.

  18. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  19. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    Science.gov (United States)

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark

  20. International consensus on use of focused ultrasound for painful bone metastases : Current status and future directions

    NARCIS (Netherlands)

    Huisman, Merel; ter Haar, Gail; Napoli, Alessandro; Hananel, Arik; Ghanouni, Pejman; Lövey, György; Nijenhuis, Robbert J; van den Bosch, Maurice A A J; Rieke, Viola; Majumdar, Sharmila; Marchetti, Luca; Pfeffer, Raphael M; Hurwitz, Mark D

    2015-01-01

    Focused ultrasound surgery (FUS), in particular magnetic resonance guided FUS (MRgFUS), is an emerging non-invasive thermal treatment modality in oncology that has recently proven to be effective for the palliation of metastatic bone pain. A consensus panel of internationally recognised experts in

  1. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    Conclusions: It was concluded that the use of double 4-hole straight plates provided the sufficient stability on the osteotomy site when compared with the other rigid fixation methods used in this study. Key words: Bone plates, bone screws, finite element analysis, jaw fixation techniques, mandible, mandibular osteotomy ...

  2. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189.

    Science.gov (United States)

    La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso

    2015-10-01

    Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if

  3. Time-dependent differences in management and microbiology of orthopaedic internal fixation-associated infections: an observational prospective study with 229 patients.

    Science.gov (United States)

    Kuehl, R; Tschudin-Sutter, S; Morgenstern, M; Dangel, M; Egli, A; Nowakowski, A; Suhm, N; Theilacker, C; Widmer, A F

    2018-04-10

    Little information has been published on orthopaedic internal fixation-associated infections. We aimed to analyse time-dependent microbiology, treatment, and outcome. Over a 10-year period, all consecutive patients with internal fixation-associated infections at the University Hospital of Basel, were prospectively followed and clinical, microbiological and outcome data were acquired. Infections were classified as early (0-2 weeks after implantation), delayed (3-10 weeks), and late (>10 weeks). Two hundred and twenty-nine patients were included, with a median follow-up of 773 days (IQR 334-1400). Staphylococcus aureus was the most prevalent pathogen (in 96/229 patients, 41.9%). Enterobacteriaceae were frequent in early infections (13/49, 26.5%), whereas coagulase-negative staphylococci (36/92, 39.1%), anaerobes (15/92, 16.3%) and streptococci (10/92, 10.9%) increased in late revisions. Failure was observed in 27/229 (11.7%). Implants were retained in 42/49 (85.7%) in early, in 51/88 (57.9%) in delayed, and in 9/92 (9.8%) in late revisions (p < 0.01). Early revisions failed in 6/49 (12.2%), delayed in 9/88 (10.2%), and late in 11/92 (13.0%) (p 0.81). Debridement and retention failed in 6/42 (14.3%) for early, in 6/51 (11.8%) for delayed, and in 3/9 (33.3%) for late revisions (p 0.21). Biofilm-active antibiotic therapy tailored to resistance correlated with improved outcome for late revisions failure (6/72, 7.7% versus 6/12, 50.0%; p < 0.01) but not for early revisions failure (5/38, 13.2% versus 1/11, 9.1%; p 1.0). Treatment of internal fixation-associated infections showed a high success rate of 87-90% over all time periods. Implant retention was highly successful in early and delayed infections but only limited in late infections. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Association of bone marrow edema with temporomandibular joint (TMJ) osteoarthritis and internal derangements.

    Science.gov (United States)

    Wahaj, Aiyesha; Hafeez, Kashif; Zafar, Muhammad Sohail

    2017-01-01

    This study reviewed the dental literature in order to determine the association of bone marrow edema with osteoarthritis and temporomandibular joint (TMJ) internal derangement disorders. A literature search was performed using electronic databases PubMed/Medline (National Library of Medicine, Bethesda, Maryland) and Cochrane for articles published during the last 15 years (January 2000-December 2014). A predetermined inclusion and exclusion criteria were used for filtering the scientific papers. Research articles fulfilling the basic inclusion criteria were included in the review. The reviewed studies showed that bone marrow edema is found in painful joints with osteoarthritis in a majority of cases. A few cases with no pain or significant degenerative changes are reported to have a bone marrow edema pattern as well. Bone marrow edema, increased fluid level, and pain are associated with osteoarthritis in the majority of patients reporting TMJ arthritis. Degenerative and disc displacement conditions are multifactorial and require further investigations. Magnetic resonance imaging can be employed to detect bone marrow edema even in the absence of pain and clinical symptoms in the patients of internal derangements.

  5. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    Science.gov (United States)

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Early Rehabilitation in Elderly after Arthroplasty versus Internal Fixation for Unstable Intertrochanteric Fractures of Femur: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Yoo, Jun Il; Ha, Yong Chan; Lim, Jae Young; Kang, Hyun; Yoon, Byung Ho; Kim, Hyunho

    2017-05-01

    The purpose of this study was to compare the outcomes focusing on the functional outcome and clinical results of replacement arthroplasty (AP) vs. internal fixation (IF) for the treatment of unstable intertrochanteric femoral fracture in elderly. Systematic review and meta-analysis were performed on 10 available clinical studies (2 randomized controlled trials and 8 comparative studies). Subgroup analysis was performed by type of methodological quality. Partial weight bearing time in AP group was earlier than that in IF group (SMD = -0.86; 95% CI = -0.42, 1.29; P = 0.050). The overall outcomes such as mortality, reoperation rate, and complication showed no significant diffrence between the 2 groups (AP vs. IF). Therefore, this systematic review demonstrates that AP provides superior functional outcomes especially earlier mobilization, as compared to IF in elderly patients with an unstable intertrochanteric femoral fracture. © 2017 The Korean Academy of Medical Sciences.

  7. Arterial Injury to the Profunda Femoris Artery following Internal Fixation of a Neck of Femur Fracture with a Compression Hip Screw

    Directory of Open Access Journals (Sweden)

    Simon Craxford

    2013-01-01

    Full Text Available We report the case of an 82-year-old woman who developed extensive proximal thigh swelling and persistent anaemia following internal fixation of an extracapsular neck of femur fracture with a dynamic hip screw (DHS. This was revealed to be a pseudoaneurysm of a branch of profunda femoris artery on angiography. Her case was further complicated by a concurrent pulmonary embolism (PE. She underwent endovascular coil embolisation of the pseudoaneurysm. An IVC filter was inserted and the patient was fully anticoagulated once it had been ensured that there was no active bleeding. In this case, we review the potential for anatomical variations in the blood supply to this region and discuss treatment options for a complicated patient. We recommend that a pseudoaneurysm should be part of a differential diagnosis for postoperative patients with anaemia refractory to blood transfusion so as not to miss this rare but potentially serious complication.

  8. Operative fixation of chest wall fractures: an underused procedure?

    Science.gov (United States)

    Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David

    2007-06-01

    Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.

  9. Ilizarov fixator in management of nonunited and infected tibial shaft fractures

    Directory of Open Access Journals (Sweden)

    Abhinay Singh

    2015-01-01

    Full Text Available Background: Management of nonunion with bony defect and infection in long bones is a challenging problem for orthopedic surgeons. Objectives: Evaluation of Ilizarov circular fixation method of treatment for the management of nonunited and infected fractures of tibia. Materials and Methods: This prospective study was conducted in a tertiary care hospital of eastern region of India on 30 subjects in a time span of 3 years after taking clearance of the Institutional Ethical Committee and informed consent of the patients. Results: All the patients had infected nonunion before undergoing Ilizarov procedure. Following initial injury, 22 patients were treated with external fixation and 8 cases were treated with internal fixation. At the time of presentation, 18 patients had infected gap nonunion, 5 patients had infected hypertrophic and 2 patients had atrophic nonunion. The Ilizarov fixator was kept for an average period of 303.7 days. Based on Association for the Study and Application of Methods of Ilizarov scoring system, bony and functional results were assessed. The bony result was excellent in 16 patients, good in eight, fair in four and poor in two. The functional result was excellent in 10 patients, good in 16, fair in two, poor in two. Conclusion: Ilizarov ring fixator still remains an excellent treatment modality for tibial nonunion with a defect, regarding bone union, deformity correction, infection eradication, limb-length achievement, and limb function.

  10. Update of the International Consensus on Palliative Radiotherapy Endpoints for Future Clinical Trials in Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Edward, E-mail: Edward.Chow@sunnybrook.ca [Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON (Canada); Hoskin, Peter [Mount Vernon Centre for Cancer Treatment, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom); Mitera, Gunita; Zeng Liang [Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON (Canada); Lutz, Stephen [Department of Radiation Oncology, Blanchard Valley Regional Cancer Center, Findlay, OH (United States); Roos, Daniel [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide, South Australia (Australia); Hahn, Carol [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Linden, Yvette van der [Radiotherapeutic Institute Friesland, Leeuwarden (Netherlands); Hartsell, William [Department of Radiation Oncology, Advocate Good Samaritan Cancer Center, Downers Grove, IL (United States); Kumar, Eshwar [Department of Oncology, Atlantic Health Sciences Cancer Centre, Saint John Regional Hospital, Saint John, NB (Canada)

    2012-04-01

    Purpose: To update the international consensus on palliative radiotherapy endpoints for future clinical trials in bone metastases by surveying international experts regarding previous uncertainties within the 2002 consensus, changes that may be necessary based on practice pattern changes and research findings since that time. Methods and Materials: A two-phase survey was used to determine revisions and new additions to the 2002 consensus. A total of 49 experts from the American Society for Radiation Oncology, the European Society for Therapeutic Radiology and Oncology, the Faculty of Radiation Oncology of the Royal Australian and New Zealand College of Radiologists, and the Canadian Association of Radiation Oncology who are directly involved in the care of patients with bone metastases participated in this survey. Results: Consensus was established in areas involving response definitions, eligibility criteria for future trials, reirradiation, changes in systemic therapy, radiation techniques, parameters at follow-up, and timing of assessments. Conclusion: An outline for trials in bone metastases was updated based on survey and consensus. Investigators leading trials in bone metastases are encouraged to adopt the revised guideline to promote consistent reporting. Areas for future research were identified. It is intended for the consensus to be re-examined in the future on a regular basis.

  11. Update of the International Consensus on Palliative Radiotherapy Endpoints for Future Clinical Trials in Bone Metastases

    International Nuclear Information System (INIS)

    Chow, Edward; Hoskin, Peter; Mitera, Gunita; Zeng Liang; Lutz, Stephen; Roos, Daniel; Hahn, Carol; Linden, Yvette van der; Hartsell, William; Kumar, Eshwar

    2012-01-01

    Purpose: To update the international consensus on palliative radiotherapy endpoints for future clinical trials in bone metastases by surveying international experts regarding previous uncertainties within the 2002 consensus, changes that may be necessary based on practice pattern changes and research findings since that time. Methods and Materials: A two-phase survey was used to determine revisions and new additions to the 2002 consensus. A total of 49 experts from the American Society for Radiation Oncology, the European Society for Therapeutic Radiology and Oncology, the Faculty of Radiation Oncology of the Royal Australian and New Zealand College of Radiologists, and the Canadian Association of Radiation Oncology who are directly involved in the care of patients with bone metastases participated in this survey. Results: Consensus was established in areas involving response definitions, eligibility criteria for future trials, reirradiation, changes in systemic therapy, radiation techniques, parameters at follow-up, and timing of assessments. Conclusion: An outline for trials in bone metastases was updated based on survey and consensus. Investigators leading trials in bone metastases are encouraged to adopt the revised guideline to promote consistent reporting. Areas for future research were identified. It is intended for the consensus to be re-examined in the future on a regular basis.

  12. Chitosan-coated Stainless Steel Screws for Fixation in Contaminated Fractures

    OpenAIRE

    Greene, Alex H.; Bumgardner, Joel D.; Yang, Yunzhi; Moseley, Jon; Haggard, Warren O.

    2008-01-01

    Stainless steel screws and other internal fixation devices are used routinely to stabilize bacteria-contaminated bone fractures from multiple injury mechanisms. In this preliminary study, we hypothesize that a chitosan coating either unloaded or loaded with an antibiotic, gentamicin, could lessen or prevent these devices from becoming an initial nidus for infection. The questions investigated for this hypothesis were: (1) how much of the sterilized coating remains on the screw with simulated ...

  13. Aplastic Anemia and MDS International Foundation (AAMDSIF): Bone marrow failure disease scientific symposium 2016.

    Science.gov (United States)

    Zeidan, Amer M; Battiwalla, Minoo; Berlyne, Deborah; Winkler, Thomas

    2017-02-01

    Patients with acquired and inherited bone marrow failure syndromes (BMFS) have ineffective hematopoiesis due to impairments of the hematopoietic stem cell compartment. Common manifestations of BMFS include varying degrees of peripheral blood cytopenias and, sometimes, progression to acute myelogenous leukemia. Research efforts have been made all over the world to improve understanding of the pathogenesis of these diseases and their clinical implications. The Aplastic Anemia and MDS International Foundation (AAMDSIF) is an independent nonprofit organization whose mission is to help patients and family members cope with BMFS. Here, we summarize recent scientific discoveries in several BMFS that were presented at the fifth International Bone Marrow Failure Disease Scientific Symposium 2016 that AAMDSIF sponsored on March 17-18, 2016, in Rockville, Maryland. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. An Osteoinductive Polymer Composite for Cranial and Maxillofacial Bone Repair,

    Science.gov (United States)

    1985-01-01

    a suitable level of anesthesia , a semi-lunar incision was made in the midline from the superior sagittal crest to the middle of the nasal bone. The...internal fixation of Fractures, and as intraosseous bone repair materials. A promising use for these polymers has been as carriers for osteogenic...acids. Oral Surg. 37:142, 1974. 7. Getter, L., Cutright, D.E., Bhaskar, S.N., and Augsburg, J.K. A biodegradable intraosseous apliance in the

  15. Finite element modeling and experimentation of bone drilling forces

    International Nuclear Information System (INIS)

    Lughmani, W A; Bouazza-Marouf, K; Ashcroft, I

    2013-01-01

    Bone drilling is an essential part of many orthopaedic surgery procedures, including those for internal fixation and for attaching prosthetics. Estimation and control of bone drilling forces are critical to prevent drill breakthrough, excessive heat generation, and mechanical damage to the bone. This paper presents a 3D finite element (FE) model for prediction of thrust forces experienced during bone drilling. The model incorporates the dynamic characteristics involved in the process along with the accurate geometrical considerations. The average critical thrust forces and torques obtained using FE analysis, for set of machining parameters are found to be in good agreement with the experimental results

  16. Remodeled articular surface after surgical fixation of patella fracture in a child

    Directory of Open Access Journals (Sweden)

    Moruf Babatunde Yusuf

    2017-01-01

    Full Text Available Patella fracture is uncommon in pediatric age group and their patella is better preserved in any class of patella fracture. We reported a case of a 13-year-old male with right patella fracture nonunion. He had open reduction and internal fixation using tension band wire device. Fracture union was monitored with serial radiographs and he was followed up for 60 weeks. There was articular surface step after surgical fixation of the patella fracture. At 34 weeks postoperative, there was complete remodeling of the articular surface with good knee function after removal of the tension band wire. Children have good capacity of bone remodeling after fracture. Little retropatella step in a child after patella fracture surgical fixation will remodel with healing.

  17. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    Science.gov (United States)

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  18. Incidental internal carotid artery calcifications on temporal bone CT in children

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Bernadette; Jones, Blaise [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Blackham, Aaron [University of Cincinnati College of Medicine, Cincinnati, OH (United States)

    2007-02-15

    Incidental internal carotid artery (ICA) calcifications are occasionally noted on CT images of the brain and temporal bone. In adults, incidental calcifications have been correlated with increased incidence of hypercholesterolemia, cardiac disease, diabetes and carotid stenosis. To determine the incidence of incidental calcifications of the carotid siphon on temporal bone CT in children. We retrospectively reviewed 24 months of consecutive temporal bone CT examinations in children aged 18 years and younger. CT examinations on 663 patients were reviewed and the presence or absence of ICA calcifications was ranked as absent, questionable or definitive. In patients in whom definitive calcifications were identified, hospital charts were reviewed for evidence of diabetes mellitus, hypercholesterolemia, hypertriglyceridemia, hyperlipidemia and chronic renal disease as potential causes of early atherosclerosis. Of the 663 patients, 25% had definitive calcifications within the wall of the ICA: 6% of children younger than 2 years and 28% of children 12-19 years of age. Incidentally noted ICA calcifications are a common finding on temporal bone CT in children, most likely a physiologic response to turbulent flow at natural bends in the artery rather than secondary to underlying disease predisposing to early atherosclerotic calcification. (orig.)

  19. Incidental internal carotid artery calcifications on temporal bone CT in children

    International Nuclear Information System (INIS)

    Koch, Bernadette; Jones, Blaise; Blackham, Aaron

    2007-01-01

    Incidental internal carotid artery (ICA) calcifications are occasionally noted on CT images of the brain and temporal bone. In adults, incidental calcifications have been correlated with increased incidence of hypercholesterolemia, cardiac disease, diabetes and carotid stenosis. To determine the incidence of incidental calcifications of the carotid siphon on temporal bone CT in children. We retrospectively reviewed 24 months of consecutive temporal bone CT examinations in children aged 18 years and younger. CT examinations on 663 patients were reviewed and the presence or absence of ICA calcifications was ranked as absent, questionable or definitive. In patients in whom definitive calcifications were identified, hospital charts were reviewed for evidence of diabetes mellitus, hypercholesterolemia, hypertriglyceridemia, hyperlipidemia and chronic renal disease as potential causes of early atherosclerosis. Of the 663 patients, 25% had definitive calcifications within the wall of the ICA: 6% of children younger than 2 years and 28% of children 12-19 years of age. Incidentally noted ICA calcifications are a common finding on temporal bone CT in children, most likely a physiologic response to turbulent flow at natural bends in the artery rather than secondary to underlying disease predisposing to early atherosclerotic calcification. (orig.)

  20. Comparação dos volumes ocupados pelos diferentes dispositivos de fixação interna para fraturas do colo femoral Comparison of volumes occupied by different internal fixation devices for femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Daniel Lauxen Junior

    2012-01-01

    Full Text Available OBJETIVO: Medir o volume ocupado pelos dispositivos de fixação interna mais difundidos para o tratamento das fraturas de colo femoral, usando como aproximação os primeiros 30, 40 e 50mm de cada parafuso. O estudo visa observar qual desses implantes causa menor agressão óssea. MÉTODOS: Foram avaliados cinco modelos de parafusos canulados e quatro modelos de parafusos deslizantes (DHS encontrados no mercado nacional através de diferença de volume por deslocamento de água. RESULTADOS: A fixação com dois parafusos canulados apresentou volume significativamente menor do que com DHS nas inserções de 30, 40 e 50mm (p=0,01, 0,012 e 0,013, respectivamente, a fixação com três parafusos não apresentou significância estatística (p=0,123, 0,08 e 0,381, respectivamente e a fixação com quatro parafusos canulados apresenta volumes maiores que o DHS (p=0,072, 0,161 e 0,033. CONCLUSÕES: A fixação da cabeça femoral com dois parafusos canulados ocupa menor volume quando comparada ao DHS com diferença estatisticamente significativa. A maioria das outras combinações de parafusos não atingiram significância estatística, apesar de a fixação com quatro parafusos canulados apresentar, em média, volumes maiores que o ocupado pelo DHS.OBJECTIVE: The objective of this paper is to measure the volume occupied by the most widely used internal fixation devices for treating femoral neck fractures, using the first 30, 40 and 50 mm of insertion of each screw as an approximation. The study aimed to observe which of these implants caused least bone aggression. METHODS: Five types of cannulated screws and four types of dy namic hip screws (DHS available on the Brazilian market were evaluated in terms of volume differences through water displace ment. RESULTS: Fixation with two cannulated screws presented significantly less volume than shown by DHS, for insertions of 30, 40 and 50 mm (p=0.01, 0.012 and 0.013, respectively, fixa tion with three screws

  1. Results of screw fixation combined with cortical drilling for treatment of dorsal cortical stress fractures of the third metacarpal bone in 56 Thoroughbred racehorses

    International Nuclear Information System (INIS)

    Dallap, B.L.; Bramlage, L.R.; Embertson, R.M.

    1999-01-01

    The purpose of this study was to evaluate screw fixation with cortical drilling as a surgical treatment for dorsal cortical stress fractures of MCIII in the Thoroughbred racehorse. Details of age, sex, limb affected, fracture assessment, and post operative recommendations were obtained from medical records and radiographs. Fracture healing was assessed radiographically at the time of screw removal. Performance evaluation was determined from race records obtained from The Jockey Club Information System, Lexington, Kentucky. Fifty-six Thoroughbred racehorses were treated surgically for stress fracture of MCIII with screw fixation and cortical drilling. Stress fractures occurred primarily in the left front limb of the male 3-year-olds, in the dorsolateral cortex of the middle third of MCIII. Ninety-seven percent of the fractures travelled in a dorsodistal to palmaroproximal direction. Median period to screw removal was 2.0 months. Evaluation at time of screw removal revealed 98% of single stress fractures of the left front limb were healed radiographically. Median period to resume training was 2.75 months (single stress fractures); median period to race was 7.62 months. There was no statistically significant difference in earnings/start before and after surgical intervention. Of the 63 fractures treated, two recurred. There were no catastrophic failures, and no incisional infections

  2. Development of mathematical phantoms for calculating internal doses from radiopharmaceuticals using patients' digital picture of bone scintillation

    International Nuclear Information System (INIS)

    Akahane, K.; Kai, M.; Kusama, T.

    1996-01-01

    We made a new mathematical phantom using the patients' digital pictures of bone scintillation in nuclear medicine. The data of 99m Tc bone scintillation pictures include the information on the body sizes and shapes. In the bone scintillation pictures, no three dimensional data are available, so that the shapes and sizes of whole body and bones were modelled based on standard anatomical geometry. The organs except bone were also modelled after construction of the bone mathematical model. The mathematical phantoms were developed for each patient. The specific effective energy for each phantom can be calculated by the Monte Carlo code to compare it among the patients. Our mathematical phantoms would provide new calculation of internal doses from radiopharmaceuticals in place of the MIRD phantom. (author)

  3. Evaluating the use of antibiotic prophylaxis during open reduction and internal fixation surgery in patients at low risk of surgical site infection.

    Science.gov (United States)

    Xu, Sheng-Gen; Mao, Zhao-Guang; Liu, Bin-Sheng; Zhu, Hui-Hua; Pan, Hui-Lin

    2015-02-01

    Widespread overuse and inappropriate use of antibiotics contribute to increasingly antibiotic-resistant pathogens and higher health care costs. It is not clear whether routine antibiotic prophylaxis can reduce the rate of surgical site infection (SSI) in low-risk patients undergoing orthopaedic surgery. We designed a simple scorecard to grade SSI risk factors and determined whether routine antibiotic prophylaxis affects SSI occurrence during open reduction and internal fixation (ORIF) orthopaedic surgeries in trauma patients at low risk of developing SSI. The SSI risk scorecard (possible total points ranged from 5 to 25) was designed to take into account a patient's general health status, the primary cause of fractures, surgical site tissue condition or wound class, types of devices implanted, and surgical duration. Patients with a low SSI risk score (≤8 points) who were undergoing clean ORIF surgery were divided into control (routine antibiotic treatment, cefuroxime) and evaluation (no antibiotic treatment) groups and followed up for 13-17 months after surgery. The infection rate was much higher in patients with high SSI risk scores (≥9 points) than in patients with low risk scores assigned to the control group (10.7% vs. 2.2%, Prisk score. Implementation of this scoring system could guide the rational use of perioperative antibiotics and ultimately reduce antibiotic resistance, health care costs, and adverse reactions to antibiotics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. [Calcaneal fractures treated by open reduction and internal fixation with a locking compression plate (LCP). A prospective study. part I: basic analysis of the group].

    Science.gov (United States)

    Svatoš, F; Bartoška, R; Skála-Rosenbaum, J; Douša, P; Pacovský, V; Krbec, M

    2011-01-01

    In a prospective study of patients with calcaneal fractures treated by open reduction from an extensile lateral approach and LCP osteosynthesis, the authors evaluated the basic epidemiological data, mechanism of injury, type of fracture, essential data on surgery, days of hospital stay and the number of complications. In the period from September 1, 2006 to July 31, 2010, a total of 230 patients with 243 calcaneal fractures were treated. The fractures were classified as either open or closed and according to the Essex-Lopresti system. Of the total number of patients, 135 (55.6 % of all fractures) were indicated for conservative treatment and 108 (44.4% of all fractures) for surgical intervention. Indications for surgery based on the generally accepted criteria enabled us to select 77 patients with 82 fractures (33.7 % of all fractures) for treatment by the method of open reduction and LCP osteosynthesis. These patients constituted the group evaluated here. The other patients were treated using other techniques (21 fractures, i.e., 8.6 % of all fractures, by the Stehlík-Štulík transfixation method and further five [2.1 %] by screw osteosynthesis). Six surgeons were involved in the treatment of this group. For the diagnosis of fractures, plain radiographs in lateral and axial projection and axial and coronal CT images were used. All fractures were treated after subsidence of oedema by the method of open reduction and LCP fixation from an extensile lateral approach, with the use of a tourniquet. The follow-up period for the evaluation of functional outcome and bone union was 3 to 48 months. Fifty patients were followed up for over one year. The group evaluated comprised 58 men (75.3 %) with 63 fractures (76.8 %) and 19 women (24.7 %) with 19 fractures (23.2 %). The average age of the group was 42 years, with 41 years (range, 22-61 years) in men and 47 years (range, 30-70 years) in women. The most frequent cause of injury was a fall from a height below 1 metre and

  5. Rodent bone densitometer on the International Space Station: Instrument design and performance

    Science.gov (United States)

    Vellinger, John C.; Barton, Kenneth; Faget, Paul; Todd, Paul; Boland, Eugene

    2016-07-01

    The study of bone loss dynamics, mechanisms and countermeasures has been a publicly stated purpose of biomedical research aboard the International Space Station. Rodent research has always played a major role in terrestrial laboratories studying bone loss. The "gold standard" for assessing bone loss in human patients has been dual-energy x-ray absorptiometry (DEXA). DEXA is also widely applied to the study of bone loss in laboratory animals, so this technology has been added to the ISS inventory of analytical tools in the form of the ISS Bone Densitometer (BD) designed, constructed, tested and integrated by Techshot, Inc. (Greenville, Indiana, USA). The BD is a re-packaged COTS device known as PIXImus (GE-Lunar, USA), which was installed on ISS in November 2014 after launching on SpaceX-4. To facilitate operations in microgravity and to meet spaceflight facility and safety requirements the commercial x-ray source, control electronics and imaging system were modified and packaged by Techshot into a drawer that fits into a single EXPRESS Locker replacement. A space-rated "Exam Box" is also supplied for containment of the anesthetized subject during transfer into the BD and during exposure. The commercial software package controls four paired-energy exposures, 80 and 35 kV, and applies DEXA algorithms to the fluorescence images and displays bone mineral density (BMD), bone mineral content, lean mass, fat mass, total mass and per cent fat. The BD is therefore also a means for measuring mass and body composition making it a versatile tool for many types of rodent studies on orbit. The BD has been operated multiple times on orbit, and its performance has not differed significantly from its performance on the ground. It has been shown to measure body mass with a precision of +/- 0.1 g and on-orbit accuracy of -0.3 g. It is expected to detect BMD losses of approximately 2%. The image data are stored in a manner that allows post-test data analysis especially including the

  6. Incidence of infection following internal fixation of open and closed tibia fractures in India (INFINITI): a multi-centre observational cohort study.

    Science.gov (United States)

    Doshi, Prakash; Gopalan, Hitesh; Sprague, Sheila; Pradhan, Chetan; Kulkarni, Sunil; Bhandari, Mohit

    2017-04-14

    Trauma is a major public health problem, particularly in India due to the country's rapid urbanization. Tibia fractures are a common and often complicated injury that is at risk of infection following surgical fixation. The primary objectives of this cohort study were to determine the incidence of infection within one year of surgery and to describe the distribution of infections by location and time of diagnosis for tibia fractures in India. We conducted a multi-center, prospective cohort study. Patients who presented with an open or closed tibia fracture treated with internal fixation to one of the participating hospitals in India were invited to participate in the study. Participants attended follow-up visits at 3, 6, and 12 months post-surgery, where they were assessed for infections, fracture healing, and health-related quality of life as measured by the EurQol-5 Dimensions (EQ-5D). Seven hundred eighty-seven participants were included in the study and 768 participants completed the 12 month follow-up. The overall incidence of infection was 2.9% (23 infections). The incidence of infection was 1.6% (10 infections) in closed and 8.0% (13 infections) in open fractures. There were 7 deep and 16 superficial infections, with 5 being early, 7 being delayed, and 11 being late infections. Intra-operative antibiotics were given to 92.1% of participants and post-operative antibiotics were given to 96.8% of participants. Antibiotics were prescribed for an average of 8.3 days for closed fractures and 9.1 days for open fractures. Infected fractures took significantly longer to heal, and participants who had an infection had significantly lower EQ-5D scores. The incidence of infection within this cohort is similar to those seen in developed countries. The duration of prophylactic antibiotic use was longer than standard practice in North America, raising concern for the potential development of antibiotic resistant microbes within Indian orthopaedic settings. Future

  7. Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

    Directory of Open Access Journals (Sweden)

    HamidReza Arab

    2015-09-01

    Full Text Available Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3i implant (3i Implant Innovation, Palm Beach Gardens, FL, USA. The evaluations were performed one year after loading. Materials and Methods: A total of 39 implants (23 external hex, 16 internal hex were placed randomly in 23 patients (10 male, 13 female by a submerged approach. None of patients had compromised conditions or parafunctional habits. At placement and at one year after loading, periapical radiographs were taken via the parallel method from the implant sites. Results: Crestal bone loss was -0.712±0.831 mm in implants with an internal hex connection and -0.139±0.505 mm in implants with an external hex connection (P≤0.05. No correlation was found between crestal bone loss and parameters such as age, gender, jaw, implant location (anterior, premolar, or molar, implant diameter, or implant length. Conclusions: Crestal bone loss was greater in patients with internal hex 3i implants than in those with external implants. Similar results in other clinical factors were found between the groups.

  8. Report on survey of international cooperation possibility on chemical CO2 fixation and utilization technology in FY 1997; 1997 nendo chosa hokokusho (kagakuteki CO2 koteika yuko riyo gijutsu ni kakawaru kokusai kyoryoku kanosei chosa)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This survey focused on the end of the more promising companion and promoting the international cooperation on chemical CO2 fixation and utilization technology. As a result, the way of the carrying-forward of the international cooperation with more than one companion could be arranged beforehand. It led to getting an arrangement about a secrecy agreement respectively with Lurgi company and ABB company in Europe, and to providing a catalyst sample developed by RITE to implement an examination by the other party and to show related technical information. In addition, it concluded a cooperation agreement about a total system of the chemical CO2 fixation and utilization technology and methanol synthesis with ZSW. In Australia, negotiation about international cooperation with CSIRO which is a federal research organization and CRC (Cooperative Research Centre) for renewable energy has been started. The ideal circumstances are being ready for the chemical CO2 fixation project for which the international cooperation with the country where the natural energy is rich like Australia is essential when coming to practical use. To do alternating current with further high density in the following year it is desired to build a concrete study cooperation system. 1 fig., 4 tabs.

  9. Analysis and an overview of fixators in medicine and the methods of processing materials for producing fixators

    Directory of Open Access Journals (Sweden)

    Dalibor Milojko Đenadić

    2013-06-01

    Full Text Available The fixator is a medical device that provides support to fractured biological structures. Metal biomaterials are mainly used for replacing broken or damaged hard tissues such as bones because of their high strenght, toughness and corrosion resistance. Materials such as stainless steel, titanium and aluminium alloys (Ti-6Al-4V, cobalt and chromium alloys, composite materials and other biocompatible materials are used in orthopedy for the stabilization of connective tissue injuries or as a substitute for the bone tissues. Fixators are classified according to the place of installation to external and internal fixators. Widely used medical fixators are pins, rods plates, screws, pipes, wires, nails and external fixators. Conventional and non-conventional methods of processing are used in the production process for all types of fixators. Introduction Fixators are medical devices manufactured to support damaged biological structures. In the field of orthopedic surgery that deals with skeletal disorders such as bone, spine, joints, muscles and tendons injuries and diseases, various metals, titanium and cobalt alloys etc. are used to stabilize the supporting tissue injuries or as a substitute for bone tissues. Metallic implants are frequently used in orthopedic surgery as joint prosthesis (hip, knee and elbow fracture fixation devices (plates, screws, external fixators and devices for the fixation of the spine. In principle, fixators are devided into external and internal ones, depending on the place of installation (outside or inside the body. The most common types of medical fixators are pins, rods and plates. This paper presents some of the most common materials used for the production of fixators, their processing and possibilties of use in medicine for various purposes. Types of fixators and materials used for their production Nowadays, biocompatible materials are usually used for the production of fixators and implants. These materials show good

  10. Prevention of unrecognized joint penetration during internal fixation of hip fractures: a geometric model based on Steinmetz Solid.

    Science.gov (United States)

    Mao, Yujiang; Song, Jie; Wei, Jie; Wang, Manyi

    2010-01-01

    Unrecognized joint penetration (UJP) by screw penetration through the articular surface undetectable on routine anteroposterior (AP) and lateral radiographs can cause serious complications. We have developed a geometric model to analyze UJP, and methods for the prevention of the problem. A Steinmetz Solid (SS) is the overlapping portion between two identical, vertically intersecting cylinders. The AP and lateral radiographs of a femoral head (simplified as a sphere) are projections of two cylinder-shaped images. A screw that appears to be within the femoral head in fact only lies within the cylinder. A screw apparently within the femoral head on both AP and lateral images is only confined to the SS generated by two cylinders, but not necessarily confined to the femoral head itself. We have therefore analyzed UJP using a geometric model based on SS. The geometric basis of UJP lies in the fact that the SS is larger than the sphere (femoral head) with a volume ratio of 4: π. The theoretical risk of UJP for any screw therefore can be as high as 21.5% ((4-π)/4). In reality, screws are always carefully placed to ensure a distance between the screw's tip and the edge of femoral head (tip-to-edge distance, or TED). This TED effectively lowers the risk of UJP by reducing the size of the screw-confining SS. When the SS entirely fits into (internally tangential to) the femoral head, the risk of UJP approaches zero. A TED fulfilling this requirement can be regarded as safe (approximately 0.29 x femoral head radius). With a femoral head diameter of 5 cm, the safe TED is approximately 7 mm.

  11. Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description

    Directory of Open Access Journals (Sweden)

    Wilson David A

    2007-11-01

    Full Text Available Abstract The purpose of this investigation was to design and verify the capabilities of an in vitro loading-measurement system that mimics in vivo unconstrained three dimensional (3D relative motion between long bone ends, applies uniform load components over the entire length of a test specimen, and measures 3D relative motion between test segment ends to directly determine test segment construct stiffness free of errors due to potting-fixture-test machine finite stiffness. Intact equine cadaveric radius bones, which were subsequently osteotomized/ostectomized and instrumented with bone plates were subjected to non-destructive axial, torsion, and 4-point bending loads through fixtures designed to allow unconstrained components of non-load associated 3D relative motion between radius ends. 3D relative motion between ends of a 50 mm long test segment was measured by an infrared optical tracking system to directly determine its stiffness. Each specimen was then loaded to ultimate failure in either torsion or bending. Cortical bone cross-section diameters and published bone biomechanical properties were substituted into classical mechanics equations to predict the intact test segment theoretical stiffness for comparison and thus loading-measurement system verification. Intact measured stiffness values were the same order of magnitude as theoretically predicted. The primary component of relative motion between ends of the test segment corresponded to that of the applied load with the other 3D components being evident and consistent in relative magnitude and direction for unconstrained loading of an unsymmetrical double plate oblique fracture configuration. Bone failure configurations were reproducible and consistent with theoretically predicted. The 3D loading-measurement system designed: a mimics unconstrained relative 3D motion between radius ends that occurs in clinical situations, b applies uniform compression, torsion, and 4-point bending loads

  12. External fixation of "intertrochanteric" fractures.

    Science.gov (United States)

    Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-10-10

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  13. Bone--bone marrow interface (endosteum) potential relationship of microenvironments in the regulation of response to internal emitters

    International Nuclear Information System (INIS)

    Wilson, F.D.; Pool, R.R.; Stitzel, K.; Momeni, M.H.

    1976-01-01

    The interface between bone and bone marrow is examined in relation to radiation effects, with attention to new concepts of hematopoiesis. Such concepts propose a functional role of stroma in regulating the commitment of pluripotent stem cells as well as in the production of colony stimulating activity (CSA) including candidate granulopoietin(s). Morphologic examples are included, underlining the concept that stroma (including bone) and hematopoietic elements respond as a functional unit to injury to marrow elements. The methylcellulose bone marrow culture system is reviewed as it may relate to a method for quantitation of hematopoietic colonies (CFU-C), humoral regulators for granulopoiesis (CSA), and potentially as a method of quantitating mesenchymal progenitor populations (PFU-C). Based on these and other observations cited, a model depicting a tentative positioning of cells at risk relative to bone-seeking radionuclides is presented

  14. Radiological study of the secondary reduction effect of early functional exercise on displaced intra-articular calcaneal fractures after internal compression fixation.

    Science.gov (United States)

    Chen, Wei; Liu, Bo; Lv, Hongzhi; Su, Yanling; Chen, Xiao; Zhu, Yanbin; Du, Chenguang; Zhang, Xiaolin; Zhang, Yingze

    2017-09-01

    Early post-operative exercise and weight-bearing activities are found to improve the functional recovery of patients with displaced intra-articular calcaneal fractures (DIACFs). We hypothesized that early functional exercise after surgery might have a secondary reduction effect on the subtalar joint, in particular the smaller fracture fragments that were not fixed firmly. A prospective study was conducted to verify this hypothesis. From December 2012 to September 2013, patients with unilateral DIACFs were enrolled and received a treatment consisting of percutaneous leverage and minimally invasive fixation. After surgery, patients in the study group started exercising on days two to three, using partial weight bearing starting week three, and full weight bearing starting week 12. Patients in the control group followed a conventional post-operative protocol of partial weight bearing after week six and full weight bearing after the bone healed. Computed tomography (CT) scanning was performed at post-operative day one, week four, week eight, and week 12 to reconstruct coronal, sagittal, and axial images, on which the maximal residual displacements of the fractures were measured. Function was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale at the 12th post-operative month. Twenty-eight patients in the study group and 32 in the control group were followed up for more than 12 months; their data were collected and used for the final analysis. Repeated-measures analysis of variance (ANOVA) of the maximal residual displacements of the fracture measured on CT images revealed significant differences between the study and the control groups. There were interaction effects between group and time point. Except for the first time point, the differences between the groups at all studied time points were significant. In the study group, the differences between all studied time points were significant. Strong correlations were observed between

  15. Bone--bone marrow interactions

    International Nuclear Information System (INIS)

    Patt, H.M.

    1976-01-01

    Within medullary cavities, blood formation tends to be concentrated near bone surfaces and this raises interesting questions about hematopoietic consequences of radionuclide fixation in osseous tissue. Thus, it may be important, on the one hand, to consider the medullary radiation dose distribution as well as total marrow dose from bone-bound radioelements and, on the other, to inquire about possible hematopoietic implications of radiation damage to endosteal surfaces per se. The reasons for this are discussed

  16. Artrodese do punho com fixação mínima preservando as articulações carpometacarpianas Wrist arthrodesis with minimal internal fixation preserving the carpometacarpal joints

    Directory of Open Access Journals (Sweden)

    Arlindo Gomes Pardini Júnior

    2010-01-01

    structures. In general, the results are very satisfactory, particularly for pain relief, and in the majority of cases, there is considerable functional improvement. Various techniques are described, with different methods of internal fixation, most of which include the carpometacarpal joints (CMJ in the fusion. The objective of this study is to evaluate the results of wrist arthrodesis through a technique which is simpler, more biological, more inexpensive, and does not involve the carpometacarpal joints. METHODS: 15 patients with wrist arthrodesis were evaluated (6 with sequelae of trauma, 4 Rheumatoid Arthritis, 3 Kienbock's grade IV, 1 Preiser and 1 panarthrosis. The technique consisted of the use of an iliac bone plate and internal fixation with Kirschner wires, avoiding the carpometacarpal joints. RESULTS: The evaluation was based on consolidation time (93% in 7 weeks; movements of the fingers and pronosupination; pinch and grasp strength; functional evaluation through the DASH questionnaire, pain and patient satisfaction. In general, the results were similar to those of other, more aggressive techniques, and the non-inclusion of the carpometacarpal joints did not affect the final result. CONCLUSION: wrist arthrodesis with fixation using Kirschner wires and the use of an iliac bone plate, preserving the carpometacarpal joints, gives good or excellent results which are similar to those of other techniques described. However it presents major advantages over other methods: it is less aggressive, less expensive, and does not have the inconvenience and complications associated the use of plates and screws.

  17. The management of tibial pilon fractures with the Ilizarov fixator: The role of ankle arthroscopy.

    Science.gov (United States)

    El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser

    2015-12-01

    Pilon fractures usually result from high energy trauma, and are commonly associated with extensive soft tissue damage which prevents the use of open reduction and internal fixation. This study was designed to evaluate the use of the Ilizarov external fixator in the treatment of pilon fractures of the ankle, and to determine whether arthroscopy of the ankle could improve the outcome. From February 2011 to May 2013 a total of 23 patients with unilateral closed pilon fractures were divided into two groups treated with and without arthroscopy during fixation with the Ilizarov external fixator. The fractures were classified according to the AO Rüdi and Allgőwer classification. Follow up ranged from 10 to 37 months with a mean of 18 months. All cases were evaluated at follow up by the AOFAS and the Bone et al. grading system. According to Bone et al. there were 3 cases excellent, 4 cases good, 2 cases fair, and 2 cases poor in Group A (without arthroscopy), whereas there were 4 cases excellent, 6 cases good, 2 cases fair in Group B (with arthroscopy). The AOFAS score for Group A was 77.8±5.8, and for Group B was 78.4±6.9. We concluded that the Ilizarov external fixator is an excellent method in treating pilon fractures as it minimizes the need for extensive surgery. We also conclude that the use of arthroscopy during pilon fracture fixation did not add statistically significant improvement to our results and it needs longer term investigation to assess its advantage - if any - to the final outcome. level 2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The effect on implant fixation of soaking tricalcium phosphate granules in bisphosphonate

    DEFF Research Database (Denmark)

    Jakobsen, Thomas; Baas, Jørgen; Bechtold, Joan E

    2012-01-01

    The use of bone grafting is a well-established way to enhance initial implant fixation in situations with reduced bone stock. Ceramic bone substitutes are inferior alternatives to autogenous or allogeneic bone graft. Improvement of bone graft substitutes is needed. We investigated whether...

  19. CSF coccidioides complement fixation

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003526.htm CSF coccidioides complement fixation test To use the sharing features on this page, please enable JavaScript. CSF coccidioides complement fixation is a test that checks ...

  20. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    Science.gov (United States)

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  1. Intrascleral IOL Fixation.

    Science.gov (United States)

    Jacob, Soosan

    2017-01-01

    Intrascleral sutureless intraocular lens (IOL) fixation utilizes direct haptic fixation within the sclera in eyes with deficient capsular support. This has advantages of long-term stability, good control of tilt and decentration, and lesser pseudophakodonesis. This review summarizes various techniques for intrascleral haptic fixation, results, complications, adaptations in special situations, modifications of the technique, combination surgeries, and intrascleral capsular bag fixation techniques (glued capsular hook). Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  2. Fusion Surgery Required for Recurrent Pediatric Atlantoaxial Rotatory Fixation after Failure of Temporary Fixation with Instrumentation

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Matsuyama

    2017-01-01

    Full Text Available In cases of chronic irreducible and recurrent unstable atlantoaxial rotatory fixation (AARF, closed reduction and its maintenance are often unsuccessful, requiring surgical treatment. The purpose of the present report is to describe a rare case of pediatric AARF that required multiple treatments. A 6-year-old boy was diagnosed as having type 2 AARF. After conservative treatment, the patient was treated with temporary fixation surgery (C1-C2 Magerl without a bone graft in consideration of motion preservation after screw removal. AARF recurred after the screw removal and required fusion surgery (Magerl–Brooks with an iliac bone graft. Ultimately, bone union was achieved and the screws were removed 11 months after the surgery. We recommend surgeons be cautious when choosing temporary fixation surgery for AARF in small children. Further investigation is needed to determine the optimal time before screw removal.

  3. Do Open Reduction and Internal Fixation With Articular Disc Anatomical Reduction and Rigid Anchorage Manifest a Promising Prospect in the Treatment of Intracapsular Fractures?

    Science.gov (United States)

    Cai, Bo-Lei; Ren, Rong; Yu, Hong-Bo; Liu, Peng-Chao; Shen, Steve G F; Shi, Jun

    2018-05-01

    In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. High failure rate after internal fixation and beneficial outcome after arthroplasty in treatment of displaced femoral neck fractures in patients between 55 and 70 years.

    Science.gov (United States)

    Bartels, Stefan; Gjertsen, Jan-Erik; Frihagen, Frede; Rogmark, Cecilia; Utvåg, Stein Erik

    2018-02-01

    Background and purpose - The treatment of patients between 55 and 70 years with displaced intracapsular femoral neck fracture remains controversial. We compared internal fixation (IF), bipolar hemiarthroplasty (HA) and total hip arthroplasty (THA) in terms of mortality, reoperations and patient-reported outcome by using data from the Norwegian Hip Fracture Register. Patients and methods - We included 2,713 patients treated between 2005 and 2012. 1,111 patients were treated with IF, 1,030 with HA and 572 patients with THA. Major reoperations (defined as re-osteosynthesis, secondary arthroplasty, exchange, or removal of prosthesis components and Girdlestone procedure), patient-reported outcome measures (satisfaction, pain, and health-related quality of life (EQ5D) after 4 and 12 months), 1-year mortality, and change in treatment methods over the study period were investigated. Results - Major reoperations occurred in 27% after IF, 3.8% after HA and 2.8% after THA. 549 patients (20% of total study population) answered both questionnaires. Compared with IF, patients treated with THA were more satisfied after 4 and 12 months, reported less pain after 4 months and 12 months, had a higher EQ5D-index score after 4 months and 12 months, and EQ-VAS score after 4 months. Compared with IF, patients treated with HA were more satisfied and reported less pain after 4 months. EQ5D-index and EQ-VAS were similar. Patients treated with HA had higher 1-year mortality and had more comorbidities than both the THA and IF group. All these differences were statistically and clinically significant. Interpretation - This study showed high reoperation rate after IF and better patient-reported outcome after both THA and HA with medium follow-up. Patients selected for HA represented a frailer group than patients treated with THA or IF.

  5. Biodegradable interlocking nails for fracture fixation

    NARCIS (Netherlands)

    van der Elst, M.; Bramer, J. A.; Klein, C. P.; de Lange, E. S.; Patka, P.; Haarman, H. J.

    1998-01-01

    Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant

  6. Fixation of fractures of the condylar head of the mandible with a new magnesium-alloy biodegradable cannulated headless bone screw.

    Science.gov (United States)

    Leonhardt, H; Franke, A; McLeod, N M H; Lauer, G; Nowak, A

    2017-07-01

    It is difficult to fix fractures of the condylar head of the mandible. Several techniques have been described which show satisfactory outcomes, but stability can be questionable, and some can cause irritation of the soft tissues. We describe a technique and first results of treating such fractures with resorbable magnesium-based headless bone screws (Magnezix ® 2.7mm CS; Syntellix AG, Hanover, Germany). Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.

    Science.gov (United States)

    Mohammed, R; Syed, S; Metikala, S; Ali, Sa

    2011-09-01

    With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.

  8. Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients

    Directory of Open Access Journals (Sweden)

    Bhava RJ Satish

    2013-01-01

    Conclusion: Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients ≥50 years of age.

  9. Craniotomy Frontal Bone Defect

    African Journals Online (AJOL)

    2018-03-01

    Mar 1, 2018 ... Defect reconstruction and fixation of the graft: The defect of ... where all loose fragments of fractured frontal bone was removed via the ... Mandible. • Ilium. • Allograft ... pediatric patients owing to skull growth. Thus, autologous ...

  10. Premaxillary osteotomy fixation in bilateral cleft lip/palate: Introducing a new technique

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2016-04-01

    Conclusion: In protruding premaxilla, osteotomy and fixation of premaxilla with miniplate to the vomer bone during alveolar bone grafting through a lip-split approach yielded satisfactory results in patients requiring secondary functional cheilorhinoplasty.

  11. Trochanteric Fixation With a Third-Generation Cable-Plate System: An Independent Experience.

    Science.gov (United States)

    Stewart, Andrew D; Abdelbary, Hesham; Beaulé, Paul E

    2017-09-01

    Greater trochanteric fracture/nonunion can be a devastating complication with significant functional impact after total hip arthroplasty, and their fixation remains a challenge because of the significant forces being transmitted as well as the poor bone quality often associated with these fractures. The objective of this study is to investigate the rates of reoperation and trochanteric nonunion using a third-generation cable-plate system at one center. Thirty-five patients, mean age 72.9 years (range 46-98 years) with 24 women and 11 men, underwent fixation of their fractured greater trochanter using a third-generation cable-plate system. The indications were: periprosthetic fracture (n = 17), complex primary arthroplasty (n = 5), and complex revision arthroplasty (n = 13). Primary outcomes included rates of reoperation and radiographic union. At a mean follow-up of 2.5 years, trochanteric union rate was 62.9% with nonunion rate of 31.4%, and fibrous union in 5.7%. In regard to quality of initial apposition, only 40% achieved a perfect bone on bone reduction. Ten patients (28.6%) had evidence of wire breakage. Five patients (14.3%) required reoperation and removal of the internal fixation because of lateral hip pain. Fixation of the trochanteric fractures remains a challenge with a relatively high reoperation rate. Poor bone quality and capacity to maintain a stable reduction continue to make this complication after total hip arthroplasty a difficult problem to solve. Copyright © 2017. Published by Elsevier Inc.

  12. THE FUNCTIONAL OUTCOME OF MANAGEMENT OF SCHATZKER TYPE II AND III TIBIAL PLATEAU FRACTURES TREATED WITH INDIRECT ELEVATION, PERCUTANEOUS FIXATION AND BONE GRAFTING

    Directory of Open Access Journals (Sweden)

    Sheshagiri

    2016-02-01

    Full Text Available INTRODUCTION Damage to the joint is more extensive in tibia plateau fractures than the roentgenograms Indicate. It may be associated with soft tissue trauma, ligament injuries (4-33% medial Collateral ligament being the most common, meniscal injuries (20%, lateral collateral Ligament injury (3%, peroneal nerve injuries (3%. Posttraumatic arthritis is associated with residual instability or axial malalignment rather than joint depression. So we use minimally invasive approach to the depressed tibial plateau fractures (Schatzker type II & III. MATERIALS AND METHODS 32 patients were studied. They were followed up for maximum of 3yrs and a minimum of 1.5yrs with an average of 2.2yrs. Inclusion criteria included those patients with an age group between 20yrs and 60yrs, joint depression more than 3mm. Patients with open fracture, severe osteoporotic bones and with radiographic evidence of osteoarthritis are excluded from the study. CT was done in all patients. Mean age group was 28.8yrs and 19(76% were males; the mean articular depression was 11.32 mm measured in CT. Pre-op evaluation includes x-rays of the knee, stress x-rays if needed, and CT was done with 2mm limited cuts. Cancellous Bone graft was taken from opposite tibia through a 3-4cm long incision made below the tibial tuberosity over the medial aspect of the tibia. Cortical window was made in the affected limb, just enough to introduce the punch, and its position was confirmed under c-arm and depressed fragment was elevated with punch and reduction was held with k wires in subarticular plane and later two cannulated cancellous screws was introduced and the defect packed with bone grafts, Post-operatively all patients were immobilized with plaster of Paris (POP for 3 weeks and then mobilized. RESULTS The mean duration of the follow up was 2.2yrs. Results were excellent in 21 patients (84%, good 3(12% and fair in 1 patients (4% according to anatomic and functional criteria by Hohl and Luck

  13. Design and Validation of 3D Printed Complex Bone Models with Internal Anatomic Fidelity for Surgical Training and Rehearsal.

    Science.gov (United States)

    Unger, Bertram J; Kraut, Jay; Rhodes, Charlotte; Hochman, Jordan

    2014-01-01

    Physical models of complex bony structures can be used for surgical skills training. Current models focus on surface rendering but suffer from a lack of internal accuracy due to limitations in the manufacturing process. We describe a technique for generating internally accurate rapid-prototyped anatomical models with solid and hollow structures from clinical and microCT data using a 3D printer. In a face validation experiment, otolaryngology residents drilled a cadaveric bone and its corresponding printed model. The printed bone models were deemed highly realistic representations across all measured parameters and the educational value of the models was strongly appreciated.

  14. Relative effectiveness of 239Pu and some other internal emitters for bone cancer induction in beagles

    International Nuclear Information System (INIS)

    Lloyd, R.D.; Miller, S.C.; Taylor, G.N.; Bruenger, F.W.; Jee, W.S.S.; Angus, W.

    1994-01-01

    The toxicity ratio (relative effectiveness per gray of average skeletal dose) has been estimated for bone cancer induction in beagles injected as young adults with a number of bone-seeking internal emitters. These experiments yielded calculated toxicity ratios (± SD) relative to 226 Ra = 1.0 of 239 Pu = 16 ± 5 (single exposure to monomeric Pu) and 32 ± 10 (continuous exposure from an extraskeletal deposit in the body), 224 Ra = 16 ± 5 (chronic exposure) and approximately 6 ± 2 (single exposure), 228 Th = 8.5 ± 2.3, 241 Am = 6 ± 0.8, 228 Ra = 2.0 ± 0.5, 249 Cf = 6 ± 3, 252 Cf = 4 ±2, 90 Sr = 1.0 ± 0.5 (for high doses) and 0.05 ± 0.03 (for low doses) and 0.01 ± 0.01 (for extremely low doses). Because no skeletal malignancies were observed among beagles given only 253 Es, the toxicity ratio is undefined. 43 refs., 2 tabs

  15. Predictors of Time to Union After Operative Fixation of Closed Ankle Fractures.

    Science.gov (United States)

    Matson, Andrew P; Hamid, Kamran S; Adams, Samuel B

    2017-08-01

    Ankle fractures are common and represent a significant burden to society. We aim to report the rate of union as determined by clinical and radiographic data, and to identify factors that predict time to union. A cohort of 112 consecutive patients with isolated, closed, operative malleolar ankle fractures treated with open reduction and internal fixation was retrospectively reviewed for time to clinical union. Clinical union was defined based on radiographic and clinical parameters, and delayed union was defined by time to union >12 weeks. Injury characteristics, patient factors and treatment variables were recorded, and statistical techniques employed included the Chi-square test, the Student's T-test, and multivariate linear regression modeling. Forty-two (37.5%) of patients who achieved union did so in less than 12 weeks, and 69 (61.6%) of these patients demonstrated delayed union at a mean of 16.7 weeks (range, 12.1-26.7 weeks), and the remaining patient required revision surgery. Factors associated with higher rates of delayed union or increased time to union included tobacco use, bimalleolar fixation, and high energy mechanism (all punion were BMI, dislocation of the tibiotalar joint, external fixation for initial stabilization and delay of definitive management (all punion following open reduction and internal fixation of closed ankle fractures. These findings should assist with patient counseling, and help guide the provider when considering adjunctive therapies that promote bone healing. Prognostic, Level IV: Case series.

  16. Percutaneous Image-Guided Screw Fixation of Bone Lesions in Cancer Patients: Double-Centre Analysis of Outcomes including Local Evolution of the Treated Focus

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr [Institut Bergonié, Department of Radiology (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Catena, Vittorio, E-mail: v.catena@bordeaux.unicancer.fr [Institut Bergonié, Department of Radiology (France); Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Palussiere, Jean, E-mail: j.palussiere@bordeaux.unicancer.fr [Institut Bergonié, Department of Radiology (France); Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-10-15

    AimTo review outcomes and local evolution of treated lesions following percutaneous image-guided screw fixation (PIGSF) of pathological/insufficiency fractures (PF/InF) and impeding fractures (ImF) in cancer patients at two tertiary centres.Materials and methodsThirty-two consecutive patients (mean age 67.5 years; range 33–86 years) with a range of tumours and prognoses underwent PIGSF for non/minimally displaced PF/InF and ImF. Screws were placed under CT/fluoroscopy or cone-beam CT guidance, with or without cementoplasty. Clinical outcomes were assessed using a simple 4-point scale (1 = worse; 2 = stable; 3 = improved; 4 = significantly improved). Local evolution was reviewed on most recent follow-up imaging. Technical success, complications, and overall survival were evaluated.ResultsThirty-six lesions were treated with 74 screws mainly in the pelvis and femoral neck (58.2 %); including 47.2 % PF, 13.9 % InF, and 38.9 % ImF. Cementoplasty was performed in 63.9 % of the cases. Technical success was 91.6 %. Hospital stay was ≤3 days; 87.1 % of lesions were improved at 1-month follow-up; three major complications (early screw-impingement radiculopathy; accelerated coxarthrosis; late coxofemoral septic arthritis) and one minor complication were observed. Unfavourable local evolution at imaging occurred in 3/24 lesions (12.5 %) at mean 8.7-month follow-up, including poor consolidation (one case) and screw loosening (two cases, at least 1 symptomatic). There were no cases of secondary fractures.ConclusionsPIGSF is feasible for a wide range of oncologic patients, offering good short-term efficacy, acceptable complication rates, and rapid recovery. Unfavourable local evolution at imaging may be relatively frequent, and requires close clinico-radiological surveillance.

  17. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  18. Internal targeted radiotherapy for bone metastasis: what about underlying physiopathology; Radiotherapie interne vectorisee (metabolique) des metastases osseuses: quid de la physiopathologie sous-jacente?

    Energy Technology Data Exchange (ETDEWEB)

    Vuillez, J.Ph. [Centre Hospitalier Universitaire, Hopital Michallon, Service de Biophysique et Medecine Nucleaire, 38 - Grenoble (France); Laval, G. [Centre Hospitalier Universitaire, Hopital Michallon, Unite de Recherche et de Soutien en Soins Palliatifs, 38 - Grenoble (France)

    2006-03-15

    Once tumours metastasize to bone, they are usually incurable and responsible for several devastating consequences: severe pain, pathologic fractures, life-threatening hypercalcemia, spinal cord compression and other nerve-compression syndromes. Understanding of physiopathological mechanisms responsible for these symptoms is critical for therapeutic approach, especially pain treatments. Three types of pain occur in tumour bone involvement: tonic or background pain, which are deep non-specific ache rising in intensity as the disease progresses; incident pain on movement (allodynia); and spontaneous pain which can be severe. Bone metastases could be osteolytic or osteoblastic. However, this classification actually represents two extremes of a continuum characterized by dys-regulation of the normal bone remodeling process. Biochemical mediators production is crucial as a part of this process. The bone microenvironment plays a critical role in the formation of osteoclasts through the production of macrophage colony-stimulating factor, receptor activator of nuclear factor kB ligand (RANKL)... Many of these mediators of osteolysis also have been shown to activate nociceptors: prostaglandins A and E, IL-1, IL-6, TNF. Thus there is a link between osteolytic destruction, inflammation and pain. It explains that severe pain could occur independently from fractures and in absence of any bone structure alteration and nervous compression. Also, pain is often disproportionate to tumour size or degree of bone involvement. Inflammatory and osteolytic processes depend on number, localization and organization of tumour cells inside bone and bone marrow tissues. All these parameters are crucial to take into account for a good understanding of treatments mechanisms of action, especially anti-inflammatory drugs (corticosteroid and others), bi-phosphonates, internal radiotherapy (strontium 89 or radiolabelled bi-phosphonates), external radiotherapy and chemotherapy or hormonotherapy

  19. Correção de falhas ósseas diafisárias: trasnporte ósseo fixado com placa Corretive procedure in diaphyseal bone gaps: bone trasnpot fixated with plate

    Directory of Open Access Journals (Sweden)

    Celso Hermínio Ferraz Picado

    2007-01-01

    Full Text Available O objetivo deste estudo é descrever um novo sistema de transporte ósseo que dispensa o uso de fios transfixantes. O sistema, constituído por uma placa, um carro móvel e por um dispositivo tracionador, foi instalado na tíbia direita de 17 ovelhas para preencher um defeito ósseo de 1 cm. O transporte ósseo foi iniciado 7 dias após a cirurgia numa taxa de 0,8 mm/dia, dividido em 0,2 mm a cada 6 horas. Radiografias em ântero-posterior e perfil foram realizadas imediatamente após a cirurgia e semanalmente até o término do transporte. Em todos os 12 animais que completaram o estudo, o defeito ósseo foi preenchido com formação do regenerado e consolidação do foco alvo. O estudo demonstra que o sistema aqui apresentado realiza o transporte ósseo de maneira efetiva, eliminando o uso de fios ou pinos transfixantes.The objective of this study is to describe a new bone transport system not requiring the use of transfixating wires. The system, which is constituted by a plate, a movable conveyor and a hauling device, was set up on the right tibia of 17 sheep intending to fill a 1-cm bone gap. Bone transport started 7 days after surgery on a rate of 0.8 mm/day, divided into 0.2 mm at each 6 hours. X-ray images of anteroposterior and lateral planes were taken immediately after surgery and on a weekly basis until transport was finished. In all 12 animals completing the study, the bone gap was filled with regenerated formation and target focus consolidation. The study shows that the system presented here effectively performs bone transport, eliminating the use of transfixating wires or pins.

  20. Bohler's angle's role in assessing the injury severity and functional outcome of internal fixation for displaced intra-articular calcaneal fractures: a retrospective study.

    Science.gov (United States)

    Su, Yanling; Chen, Wei; Zhang, Tao; Wu, Xingwang; Wu, Zhanpo; Zhang, Yingze

    2013-09-24

    Controversy exits over the role of Böhler's angle in assessing the injury severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following internal fixation. This study aims to investigate whether a correlation exists between Böhler's angle and the injury severity of displaced calcaneal fractures, and between surgical improvement of Böhler's angle and functional outcome. Patients treated operatively for unilateral closed displaced intra-articular calcaneal fractures from January 1, 2004 to March 31, 2008 were identified. The Böhler's angles of both calcaneus were measured, and the measurement of the uninjured foot was used as its normal control. The difference in the value of Böhler's angle measured preoperatively or postoperatively between the angle of the injured foot and that of the contralateral calcaneus were calculated, respectively. The change in Böhler's angle by ratio was calculated by dividing the difference value of Böhler's angle between bilateral calcaneus by its normal control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot & Ankle Society hindfoot scores. 274 patients were included into the study with a mean follow-up duration of 71 months. According to Sanders classification, the fracture pattern included 105 type II, 121 type III and 48 type IV fractures. According to American Orthopaedic Foot & Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 104, 132, 27, and 11 patients, respectively. The preoperative Böhler's angle, difference value of Böhler's angle between bilateral calcaneus, and change in Böhler's angle by ratio each has a significant correlation with Sanders classification (rs=-0.178, P=0.003; rs=-0.174, P=0.004; rs=-0.172, P=0.005, respectively), however, is not correlated with functional outcome individually. The three postoperative measurements

  1. High incidence of osteochondral lesions after open reduction and internal fixation of displaced ankle fractures: Medium-term follow-up of 100 cases.

    Science.gov (United States)

    Regier, Marc; Petersen, Jan Philipp; Hamurcu, Ahmet; Vettorazzi, Eik; Behzadi, Cyrus; Hoffmann, Michael; Großterlinden, Lars G; Fensky, Florian; Klatte, Till Orla; Weiser, Lukas; Rueger, Johannes M; Spiro, Alexander S

    2016-03-01

    The incidence of osteochondral lesions (OCLs) in association with displaced ankle fractures has only been examined in two previous studies. In both studies magnetic resonance imaging (MRI) was performed prior to open reduction and internal fixation (ORIF). Because MRI may overdiagnose or overestimate the extent of OCLs in an acute trauma setting the aim of this study was to determine the incidence of OCLs after ORIF of displaced ankle fractures using MRI at medium-term follow-up, and to analyse if the severity of fracture or the clinical outcome correlates with the incidence of OCLs. Following institutional review board approval a total of 100 patients (mean age, 41.3 years; range, 17.9-64.3 years) with a displaced ankle fracture who had undergone ORIF according to the AO principles were included in this study. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used to quantify the clinical outcome and MR images were evaluated for OCLs of the talus and distal tibia after a mean of 34.5 months (range, 17.5-54.1 months). OCLs were found in 40.4% of the patients. Logistic regression revealed a significant correlation between the severity of fracture and the incidence of OCLs. Patients with a trimalleolar fracture (p=0.04) or an ankle fracture dislocation (p=0.003) had a significantly higher risk for developing an OCL compared to those with a type B fracture. Logistic regression also demonstrated a significant correlation between the clinical outcome (AOFAS score) and the incidence of OCLs (p=0.01). The risk for developing an OCL increases up to 5.6% when the AOFAS score decreases by one point. OCLs were frequently found in association with acute ankle fractures at medium-term follow-up, and the severity of fracture was associated with an increased number of OCLs. Considering the disadvantages of MRI including the high cost and limited availability, the results of this study may help to explain why anatomic surgical realignment of displaced

  2. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  3. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    Science.gov (United States)

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make

  4. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    International Nuclear Information System (INIS)

    Kim, Jong Dae; Oh, Chae Youn; Kim, Cheol Sang

    2008-01-01

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  5. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Dae [Jeonju University, Jeonju (Korea, Republic of); Oh, Chae Youn; Kim, Cheol Sang [Chonbuk National University, Jeonju (Korea, Republic of)

    2008-12-15

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  6. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures

    Directory of Open Access Journals (Sweden)

    Vegt P

    2014-12-01

    Full Text Available Paul Vegt,1 Jeffrey M Muir,2 Jon E Block2 1Department of Surgery, Albert Schweitzer Hospital, Dordrecht, The Netherlands; 2The Jon Block Group, San Francisco, CA, USA Abstract: The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS. Keywords: osteoporosis, long bone fracture, bone density, polymeric rod, orthopaedics, surgery

  7. Management Strategy for Unicameral Bone Cyst

    Directory of Open Access Journals (Sweden)

    Chin-Yi Chuo

    2003-06-01

    Full Text Available The management of a unicameral bone cyst varies from percutaneous needle biopsy, aspiration, and local injection of steroid, autogenous bone marrow, or demineralized bone matrix to the more invasive surgical procedures of conventional curettage and grafting (with autogenous or allogenous bone or subtotal resection with bone grafting. The best treatment for a unicameral bone cyst is yet to be identified. Better understanding of the pathology will change the concept of management. The aim of treatment is to prevent pathologic fracture, to promote cyst healing, and to avoid cyst recurrence and re-fracture. We retrospectively reviewed 17 cases of unicameral bone cysts (12 in the humerus, 3 in the femur, 2 in the fibula managed by conservative observation, curettage and bone grafting with open reduction and internal fixation, or continuous decompression and drainage with a cannulated screw. We suggest percutaneous cannulated screw insertion to promote cyst healing and prevent pathologic fracture. We devised a protocol for the management of unicameral bone cysts.

  8. Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion.

    Science.gov (United States)

    Greinwald, Markus; Varady, Patrick A; Augat, Peter

    2017-12-14

    External fixation is associated with the risk of pin loosening and pin infection potentially associated to thermal bone necrosis during pin insertion. This study aims to investigate if the use of external fixator systems with unicortical pins reduces the heat production during pin insertion compared to fixators with bicortical pins. Porcine bone specimens were employed to determine bone temperatures during insertion of fixator pins. Two thermographic cameras were used for a simultaneous temperature measurement on the bone surface (top view) and a bone cross-section (front view). Self-drilling unicortical and bicortical pins were inserted at different rotational speeds: (30-600) rpm. Maximum and mean temperatures of the emerging bone debris, bone surface and bone cross-section were analyzed. Maximum temperatures of up to 77 ± 26 °C were measured during pin insertion in the emerging debris and up to 42 ± 2 °C on the bone surface. Temperatures of the emerging debris increased with increasing rotational speeds. Bicortical pin insertion generated significantly higher temperatures at low insertion speed (30 rpm) CONCLUSION: The insertion of external fixator pins can generate a considerable amount of heat around the pins, primarily emerging from bone debris and at higher insertion speeds. Our findings suggest that unicortical, self-drilling fixator pins have a decreased risk for thermal damage, both to the surrounding tissue and to the bone itself.

  9. 全髋关节置换与内固定治疗股骨颈骨折临床疗效比较%Comparison of internal fixation with total hip replacement for displaced femoral neck fractures

    Institute of Scientific and Technical Information of China (English)

    屈铁男; 陈洪瑜; 王志刚

    2014-01-01

    control ed trials performed postoperatively have shown that a primary total hip replacement is superior to internal fixation for the treatment of a femoral neck fracture in a relatively healthy, mental y competent, elderly patient. The primary aim of the present study was to evaluate the outcomes. METHODS: 58 patients who had an acute femoral neck fracture were randomly al ocated to be treated with total hip replacement or internal fixation. 24 cases (A group)were treated by IF,and 34 cases(B group) were treated by THR. RESULTS: At the 3.8 years fol ow-up evaluation, the rate of hip complications was 8.8% in the patients treated with total hip replacement and 37.5% in those treated with internal fixation .The hip function was significantly better and the decline in health-related quality of life was less pronounced in the arthroplasty group than it was in the fixation group CONCLUSIONS: Compared with internal fixation, primary total hip replacement provides a better outcome for mental y competent elderly patients with a femoral neck fracture. If we can decrease the rate of the un-union ,then internal fixation was also good method.%对施行内固定或全髋关节置换术后的新鲜老年股骨颈骨折患者的临床随访,总结所取得的经验和教训。材料及方法:我们对1997年6月-2004年10月间施行内固定或全髋关节置换术的老年患者(65岁以上)进行随访,获得随访58例,其中A组24例行空心拉力螺钉固定;B组34例行人工全髋关节置换。对其手术后功能恢复情况平均随访时间3.8年。结果:34例全髋关节置换(T H A)患者术后优良率91.2%(22例);24例内固定(I F)患者术后优良率62.5%;A组严重并发症中有7例为骨折不愈合、股骨头坏死2例。结论:对于老年股骨颈骨折的治疗,全髋关节置换是一种有效的治疗方式;如果能够有效降低较高的骨折不愈合率,多枚中空拉力螺钉内固定也是一种可行的选择。

  10. Outcome of 28 open pilon fractures with injury severity-based fixation.

    Science.gov (United States)

    Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence

    2015-04-01

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.

  11. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  12. Guide to radiation fixatives

    International Nuclear Information System (INIS)

    Tawil, J.J.; Bold, F.C.

    1983-11-01

    This report identifies and then characterizes a variety of substances available in the market place for potential effectiveness as a fixative on radiologically contaminated surfaces. The substances include both generic chemicals and proprietary products. In selecting a fixative for a particular application, several attributes of the fixative may be relevant to the choice. These attributes include: toxicity, durability, and cleanliness and removability. In addition to the attributes of the fixative, one should also take into account certain characteristics of the site to be treated. These characteristics relate to climate, nature of the surface, use to which the treated surface will be put, subsequent cleanup operations, and type of neighboring surfaces. Finally, costs and potential environmental effects may influence the decision. A variety of fixatives are evaluated with respect to these various attributes and summarized in a reference table

  13. Surgical management of proximal splint bone fractures in the horse

    International Nuclear Information System (INIS)

    Peterson, P.R.; Pascoe, J.R.; Wheat, J.D.

    1987-01-01

    Fractures of Metacarpal and Metatarsal II and IV (the splint bones) were treated in 283 horses over an 11 year period. In 21 cases the proximal portion of the fractured bone was stabilized with metallic implants. One or more cortical bone screws were used in 11 horses, and bone plates were applied in 11 horses. One horse received both treatments. Complications of screw fixation included bone failure, implant failure, radiographic lucency around the screws, and proliferative new bone at the ostectomy site. Only two of the horses treated with screw fixation returned to their intended use. Complications of plate fixation included partial fixation failure (backing out of screws), wound drainage, and proliferative bony response around the plate. Six of the 11 horses treated by plate fixation returned to their intended use. The authors recommend consideration of plate fixation techniques for repair of fractures in the proximal third of the splint bone

  14. Reproducing the internal and external anatomy of fossil bones: Two new automatic digital tools.

    Science.gov (United States)

    Profico, Antonio; Schlager, Stefan; Valoriani, Veronica; Buzi, Costantino; Melchionna, Marina; Veneziano, Alessio; Raia, Pasquale; Moggi-Cecchi, Jacopo; Manzi, Giorgio

    2018-04-21

    We present two new automatic tools, developed under the R environment, to reproduce the internal and external structures of bony elements. The first method, Computer-Aided Laser Scanner Emulator (CA-LSE), provides the reconstruction of the external portions of a 3D mesh by simulating the action of a laser scanner. The second method, Automatic Segmentation Tool for 3D objects (AST-3D), performs the digital reconstruction of anatomical cavities. We present the application of CA-LSE and AST-3D methods to different anatomical remains, highly variable in terms of shape, size and structure: a modern human skull, a malleus bone, and a Neanderthal deciduous tooth. Both methods are developed in the R environment and embedded in the packages "Arothron" and "Morpho," where both the codes and the data are fully available. The application of CA-LSE and AST-3D allows the isolation and manipulation of the internal and external components of the 3D virtual representation of complex bony elements. In particular, we present the output of the four case studies: a complete modern human endocast and the right maxillary sinus, the dental pulp of the Neanderthal tooth and the inner network of blood vessels of the malleus. Both methods demonstrated to be much faster, cheaper, and more accurate than other conventional approaches. The tools we presented are available as add-ons in existing software within the R platform. Because of ease of application, and unrestrained availability of the methods proposed, these tools can be widely used by paleoanthropologists, paleontologists and anatomists. © 2018 Wiley Periodicals, Inc.

  15. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  16. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  17. K-wire and tension band wire fixation in treating sternoclavicular joint dislocation

    Directory of Open Access Journals (Sweden)

    CHEN Qing-yu

    2011-02-01

    Full Text Available 【Abstract】Objective: To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. Methods: This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years. The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. Results: All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood’s rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. Conclusions: The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages. Key words: Sternoclavicular joint; Dislocations; Bone wires; Fracture fixation, internal

  18. Comparative study of internal contamination of different radiators in skeleton on induction of mutagenic effect in bone marrow cells

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Liuyi; Yang Weidong

    1990-10-01

    The purpose of the present study was to ascertain comparative retention of 134 Cs or 147 Pm in skeleton on induction of chromosome aberrations and PCE's micronucleus formation in bone marrow cells. Results indicated that after iv signal nuclide 134 Cs, through 7 weeks observation, the retention data in skeleton could be well described by an exponential expression. Experiments indicated that the retention value and the absorption dose of 147 Pm in skeleton were significantly higher in comparison with 134 Cs. Both internal contamination of 134 Cs or 147 Pm could induce chromosome aberrations and PCE's micronucleus formation in bone marrow cells. Among the type of chromosome aberrations of bone marrow cells induced by 134 Cs or 147 Pm included gap, chromatid breakage, chromosome breakage and translocation. Moreover, the chromosome aberration rates were elevated when the intake of radioactivity of 134 Cs or 147 Pm were enlarged. At the same time, chromosome fragment of bone marrow cells also induced by 134 Cs or 147 Pm only through high radioactive contamination. Studies showed that chromosome translocation was appeared only through high radioactivity of 147 Pm contamination. By comparing with 1 '4 7 Pm, however, the induction of chromosome aberrations and PCE's micronucleus formation rates on bone marrow cells induced by 134 Cs was quite low

  19. Scaphoid Fracture Fixation with an Acutrak? Screw

    OpenAIRE

    Loving, Vilert A.; Richardson, Michael L.

    2015-01-01

    We report a case of fixation of a scaphoid fracture using an Acutrak? screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compression across a fracture as the screw is advanced, and gives the screw its unique appearance. This featur...

  20. Results of application of external fixation with different types of fixators

    Directory of Open Access Journals (Sweden)

    Grubor Predrag

    2012-01-01

    Full Text Available Introduction. Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. Objective. The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. Methods. To determine the investigation methodology of biomechanical characteristics of the external fixator we used mathematical and computer simulator (software, juvidur physical model and clinical examination. Results. Values of advancing fragments in millimetres obtained by the study of mathematical and computer simulator (software: Charnley - 0.080 mm, Mitković M 20 - 0.785 mm, Ilizarov - 2.245 mm and Ortofix - 1.400 mm. In testing the juvidur model the following values were obtained: the external fixator Mitković M20 - 1.380 mm, Ortofix - 1.470 mm, Ilizarov - 2.410 mm, and Charnley - 2.510 mm. Clinical research of biomechanical characteristics of the effect of vertical force yielded the following results: Mitković M20 - 0.89 mm, Ortofix - 0.14 mm, Charnley - 0.80 mm and Ilizarov - 1.23 mm. Conclusion. When determining the total number of the stability test splints under the effect of vertical force (compression and force effect in antero-posterior, later-lateral plane of cross, spiral and comminuted long bone fractures, the best unified biomechanical stability was shown by the following external fixators: firstly, Mitković M20 (0.93mm, secondly, Charnley fixator (1.14 mm, thirdly, Ortofix (1.22 mm, and fourthly, Ilizarov (1.60 mm.

  1. Improved Bone Graft Method for Upper Cervical Surgery with Posterior Approach: Technical Description and Report of 52 Cases.

    Science.gov (United States)

    Wang, Yong-Li; Wang, Xiang-Yang

    2018-02-21

    We sought to report a minimum 12 months' follow-up results of our improved bone graft method for upper cervical surgery with the posterior approach. Among 52 consecutive cases, odontoid nonunion occurred in 33 patients, atlantoaxial instability in 11 patients, and occipitocervical deformity in 8 patients who underwent posterior C1-C2 transarticular screw/screw-rod internal fixation (41 cases) and occipitocervical fusion (11 cases) with the improved bone graft technique. Each surgical procedure was performed by the same senior spine surgeon. We took lateral cervical standing roentgenograms before surgery and immediately after surgery. Then we conducted craniocerebral computed tomography examination with reconstruction at 3, 6, 12, and 24 months and annually thereafter. The postoperative follow-up times are about 12-38 months. All cases showed satisfactory screw fixation by radiographic examination, and there were no postoperative neurologic complications. One case had postoperative retropharyngeal infection after the transoral release and posterior reduction by pedicle screw instrumentation. All patients got solid fusions, and no pseudarthrosis occurred. All cases had solid fusions at the 3-month follow-up. Good bone graft bed, enough bone graft material, solid local fixation, and effective bone graft method are prerequisites for a successful bone graft. By analyzing postoperative follow-up in the consecutive cases in this study, our bone graft method describing a new bone graft structure is a reliable posterior fusion technique. It is worth considering, and further research is needed. Copyright © 2018. Published by Elsevier Inc.

  2. Postinflammatory ossicular fixation: CT analysis with surgical correlation

    International Nuclear Information System (INIS)

    Swartz, J.D.; Wolfson, R.J.; Marlowe, F.I.; Popky, G.L.

    1985-01-01

    Postinflammatory ossicular fixation is a common problem encountered by the otologic surgeon upon exploration because of conductive hearing loss in patients with chronic otitis media. These nonotosclerotic noncongenital lesions take three pathologic forms: fibrous tissue fixation (chronic adhesive otitis media), hyalinization of collagen (tympanosclerosis), and new bone formation (fibro-osseous sclerosis). More than 300 patients with the clinical diagnosis of chronic otitis media have been examined. This study encompasses 23 proved cases

  3. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    Science.gov (United States)

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  4. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID: protocol for a randomized clinical multi-center trial

    Directory of Open Access Journals (Sweden)

    Seiler Christoph

    2011-03-01

    Full Text Available Abstract Background Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation. Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. Methods/Design ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool. The primary objective is to determine differences in the Short Form 36 (SF-36 Physical Component Score (PCS between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery, as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture

  5. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID): protocol for a randomized clinical multi-center trial.

    Science.gov (United States)

    Bartl, Christoph; Stengel, Dirk; Bruckner, Thomas; Rossion, Inga; Luntz, Steffen; Seiler, Christoph; Gebhard, Florian

    2011-03-22

    Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF) with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation.Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius) is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool.The primary objective is to determine differences in the Short Form 36 (SF-36) Physical Component Score (PCS) between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH) instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery), as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture involves a central statistical unit, an independent

  6. Double row anchor fixation: a novel technique for a diabetic calanceal insufficiency avulsion fracture.

    Science.gov (United States)

    Greenhagen, Robert M; Highlander, Peter D; Burns, Patrick R

    2012-01-01

    Avulsion fractures of the calcaneal tuberosity represent only 1.3% to 2.7% of calcaneal fractures. These fractures are common pathologically in nature and attributed to decreased bone mineral density. Calcaneal insufficiency avulsion (CIA) fracture in patients with diabetes mellitus is most likely due to Charcot neuroarthropathy (CN) as described by the Brodsky classification (Brodsky 3B). Traditional open reduction and internal fixation is difficult in all calcaneal avulsion fractures because of poor bone quality. The authors report the first known description of the use of fracture fragment excision and double row anchor fixation.A 39-year-old woman with type I diabetes mellitus and a history of CN presented with an avulsion fracture of the calcaneal tuberosity. Excision of the fracture fragment and a gastrocnemius recession and reattachment of the Achilles tendon with double row anchor fixation to the calcaneus were performed. At 1 year, the patient's American Orthopaedic Foot & Ankle Society rearfoot score improved from 27/100 to 88/100. CIA fractures are an infrequently described injury. Because diabetes mellitus is frequently associated with this disease, it most likely represents a CN event. Traditionally, CIA fractures have been operatively treated with open reduction internal fixation. Previous authors have described difficulty with fixation because of poor quality. In the current report, the authors describe a novel operative approach to CIA fractures through the use of double row anchor fixation and excision of the fracture fragments. The authors feel that this previously undescribed treatment is superior to traditional methods and may serve as a new treatment option for all patients who have sustained this unusual pathology regardless of the underlying cause. The current authors provide a novel operative technique that provides inherent advantages to the traditional repair of CIA fractures. We believe CIA fractures represent a CN-type event and care

  7. Clinical and Radiologic Outcomes of Submerged and Nonsubmerged Bone-Level Implants with Internal Hexagonal Connections in Immediate Implantation: A 5-Year Retrospective Study.

    Science.gov (United States)

    Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan

    2018-02-01

    To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.

  8. A case of monostotic fibrous dysplasia of proximal femur managed with curettage and cortical bone grafting

    Directory of Open Access Journals (Sweden)

    A D Sud

    2013-01-01

    Full Text Available We present a case report of a young military personnel with monostotic fibrous dysplasia of proximal femur with painful, dysplasticlesion of the femoral neck and fatigue fracture who underwent cortical bone grafting using autogenous fibular strut graft and iliac crest bone graft. The fibular cortical grafts was used to bridge the lesion in the femoral neck and were securely anchored to the normal bone of the lateral femoral cortex and a head of the femur. No supplemental internal fixation was required.

  9. Fixação interna de fragmento osteocondral originado de osteocondrite dissecante do joelho Internal fixation of osteochondral fragment originated fro dissecting knee osteochondritis

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Sanches Vaz

    2008-01-01

    Full Text Available O tratamento da osteocondrite dissecante do joelho com lesão tipo cratera associada a corpo livre intra-articular pode ser realizado pela fixação do fragmento osteocondral no seu local de origem. No entanto, existem controvérsias quanto à indicação e eficácia deste procedimento, principalmente quando o corpo livre está solto por tempo prolongado, já que existem relatos na literatura demonstrando deterioração do revestimento condral do mesmo diretamente relacionado com o intervalo decorrente de sua soltura. Relatamos um caso em que, apesar do fragmento osteocondral estar livre na articulação por aproximadamente cinco semanas, a sua fixação não trouxe complicações e resultou em cicatrização completa da lesão. Nós concluímos que, principalmente nos casos onde a lesão osteocondral no côndilo femoral envolve a superfície de carga, quando então o descarte do fragmento geralmente resultaria em mau prognóstico, as possíveis complicações da fixação tardia são compensadas pelos benefícios obtidos pela redução do fragmento osteocondral no local de origem, resultando na recuperação da congruência articular e possivelmente evitando um processo degenerativo articular precoce.The treatment of dissecting knee osteochondritis with crater-like lesion associated to intra-articular loose body can be provided by fixating the osteochondral fragment on its original site. However, there is some concern about the efficacy of this approach, since some reports have shown that the cartilage layer in osteochondral loose bodies that have been detached for a long time becomes deteriorated. We report a case where while the osteochondral loose body was detached for as long as five weeks, the fixation to the osteochondral defect was uneventful and resulted in a completely healed lesion. We concluded that, especially in cases in which the lesion involves a weight-bearing area of the knee with a detached osteochondral fragment, when the

  10. Femoral fractures : indications an[d] biomechanics of external fixation

    NARCIS (Netherlands)

    A.H. Broekhuizen (Tom); B. van Linge

    1988-01-01

    textabstractInternal fixation can be carried out in various ways. For femoral shaft fractures, an (interlocking) nail is becoming increasingly popular, instead of open realignment of the fracture. External fixation, which has become a generally accepted method of treating fractures of the lower

  11. Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

    OpenAIRE

    Wegner, Alexander; Kauther, Max Daniel; Landgraeber, Stefan; von Knoch, Marius

    2012-01-01

    Abstract Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operativ...

  12. Compacted cancellous bone has a spring-back effect

    DEFF Research Database (Denmark)

    Kold, S; Bechtold, JE; Ding, Ming

    2003-01-01

    A new surgical technique, compaction, has been shown to improve implant fixation. It has been speculated that the enhanced implant fixation with compaction could be due to a spring-back effect of compacted bone. However, such an effect has yet to be shown. Therefore we investigated in a canine mo....... Thus we found a spring-back effect of compacted bone, which may be important for increasing implant fixation by reducing initial gaps between the implant and bone....

  13. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    Science.gov (United States)

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  14. Treatment of unstable sacral fractures with percutaneous reconstruction plate internal fixation Tratamento de fraturas sacrais instáveis com reconstrução percutânea com fixação de placa interna

    Directory of Open Access Journals (Sweden)

    Hong-Wei Chen

    2012-05-01

    Full Text Available PURPOSE: To study the effects of percutaneous reconstruction plate internal fixation in the treatment of unstable sacral fractures. METHODS: Percutaneous reconstruction plate internal fixation was applied on 21 cases of unstable sacral fracture (15 males and six females, at age range of 16-65 years, mean 38.3 years including four cases of Denis Zone I, 14 cases of Zone II and three cases of Zone III. In operation, an arc incision (about 3-5 cm long was made along the iliac crest on the outside border of posterior superior iliac spine (PSIS on both sides, and then the plate was transported from the wounded side to the opposite one through the subcutaneous tunnel. RESULTS: The mean incision length, operation time, intraoperative blood loss was 4.3cm, 45.2min, and 160.8ml respectively. All these patients were followed up for 12-33 months (average 16.3 months, which showed no incision infection, intraoperative neurovascular injury, internal fixation loose or breakage, disunion, or obvious lower limb length inequality. The function result was rated as excellent in six cases, good in 12 and fair in 3, with excellence rate of 85.7%, according to the Majeed scoring system. CONCLUSION: Percutaneous reconstruction plate internal fixation is an ideal surgical approach to unstable sacral fractures, as it is easy, safe, causing less trauma and fewer complications, and conducive to quicker recovery.OBJETIVO: Estudar os efeitos da reconstrução percutânea com fixação de placa interna no tratamento de fraturas sacrais instáveis. MÉTODOS: A reconstrução percutânea com fixação de placa interna foi aplicada em 21 casos de fratura sacral instável (15 homens e seis mulheres, com idade variando entre 16 e 65 anos, média de 38,3 anos incluindo quatro casos de Zona I de Denis, 14 casos de Zona II e três casos de Zona III. No ato operatório, uma incisão arqueada (cerca de 3 a 5cm de comprimento foi feita ao longo da crista ilíaca na borda externa da

  15. OSTEOSYNTHESIS OF THE METACARPAL BONE WITH BIOABSORBABLE MATERIALS: A CASE REPORTS

    Directory of Open Access Journals (Sweden)

    Ernest Novak

    2004-04-01

    Full Text Available Background. Recent advances in biomaterial technology make it possible to produce easy-to-handle implants for osteosynthesis with ultra-high strenght and excellent biocompatibility. Biomechanical studies have shown that fixation rigidity achieved with self-reinforced (SR pins, screws and miniplates is comparable with that of metallic fixation methods. Internal fixation by means of bioabsorbable plates, screws, and pins can be used to stabilize some fractures of small bones in the hand.We report our experience with three cases where internal fixation with a SR (poly-L/DL-lactide 70/30; SR-P (L/DL LA 70/30, BioSorbTMFX miniplates and screws was carried out for stabilization of a metacarpal shaft fracture and thumb replantation.Conclusions. After bone healing is complete, metallic osteosynthesis devices become unnecessary or can even be harmful. Metallic implant-related long-term complications and secondary removal operation are avoided by using of bioabsorbable osteosynthesis devices for metacarpal bones osteosynthesis.

  16. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  17. The role of minimally invasive plate osteosynthesis in rib fixation : A review

    NARCIS (Netherlands)

    Bemelman, Michael; Van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation.

  18. Management of Lower Extremity Long-bone Fractures in Spinal Cord Injury Patients.

    Science.gov (United States)

    Schulte, Leah M; Scully, Ryan D; Kappa, Jason E

    2017-09-01

    The AO classification system, used as a guide for modern fracture care and fixation, follows a basic philosophy of care that emphasizes early mobility and return to function. Lower extremity long-bone fractures in patients with spinal cord injury often are pathologic injuries that present unique challenges, to which the AO principles may not be entirely applicable. Optimal treatment achieves healing without affecting the functional level of the patient. These injuries often result from low-energy mechanisms in nonambulatory patients with osteopenic bone and a thin, insensate soft-tissue envelope. The complication rate can be high, and the outcomes can be catastrophic without proper care. Satisfactory results can be obtained through various methods of immobilization. Less frequently, internal fixation is applied. In certain cases, after discussion with the patient, amputation may be suitable. Prevention strategies aim to minimize bone loss and muscle atrophy.

  19. BUILDING OF EXTENSIVE DIAPHYSIS DEFECTS IN LONG BONES

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2014-01-01

    Full Text Available The problem of extensive diaphysis bone defect replacement in long bones has been investigated. Treatment results of three patients (one with neoplastic process, two with supparative bone damage are given. The sizes of defects were from 16 to 20 cm. Su pervision terms consisted 1-3 years. There were two defect replacement variants: cellular titanium nickelide alongside with interlocking internal fixation - in 2 patients, and metallic prosthesis of ProSpon company (Czech Republic - in 4 patients. Two patients after segmental resection of limb bone tumours and diaphysis endoprosthesis show positive treatment results. Long-term treatment by different methods in 4 patients with chronic fistulous form of post-traumatic osteomyelitis were unsuccessful.

  20. Evaluation of marginal bone loss of dental implants with internal or external connections and its association with oth