WorldWideScience

Sample records for interaction device cpd

  1. Active particle control experiments and critical particle flux discriminating between the wall pumping and fuelling in the compact plasma wall interaction device CPD spherical tokamak

    International Nuclear Information System (INIS)

    Zushi, H.; Sakamoto, M.; Yoshinaga, T.; Higashizono, Y.; Hanada, K.; Yoshida, N.; Tokunaga, K.; Kawasaki, S.; Sato, K. N.; Nakamura, K.; Idei, H.; Hirooka, Y.; Bhattacharyay, R.; Okamoto, K.; Miyazaki, T.; Honma, H.; Nakashima, Y.; Nishino, N.; Kado, S.; Shikama, T.

    2009-01-01

    Two approaches associated with wall recycling have been performed in a small spherical tokamak device CPD (compact plasma wall interaction experimental device), that is, (1) demonstration of active particle recycling control, namely, 'active wall pumping' using a rotating poloidal limiter whose surface is continuously gettered by lithium and (2) a basic study of the key parameters which discriminates between 'wall pumping and fuelling'. For the former, active control of 'wall pumping' has been demonstrated during 50 kW RF current drive discharges whose pulse length is typically ∼300 ms. Although the rotating limiter is located at the outer board, as soon as the rotating drum is gettered with lithium, hydrogen recycling measured with H α spectroscopy decreases by about a factor of 3 not only near the limiter but also in the centre stack region. Also, the oxygen impurity level measured with O II spectroscopy is reduced by about a factor of 3. As a consequence of the reduced recycling and impurity level, RF driven current has nearly doubled at the same vertical magnetic field. For the latter, global plasma wall interaction with plasma facing components in the vessel is studied in a simple torus produced by electron cyclotron waves with I p -4 to ∼0.1 x 10 -4 Torr during the experimental campaign (∼3000 shots). In the wall pumping pressure range the wall pumping fraction is reduced with increasing surface temperature up to 150 deg. C.

  2. CPD Appropriations

    Data.gov (United States)

    Department of Housing and Urban Development — The datasets are the full-year allocations for HUD's Office of Community Planning and Development (CPD) formula programs: Community Development Block Grants (CDBG);...

  3. The CPD Maps System

    Data.gov (United States)

    Department of Housing and Urban Development — CPD Maps includes data on the locations of existing CDBG, HOME, public housing and other HUD-funded community assets, so that users can view past investments...

  4. CPD Allocations and Awards

    Data.gov (United States)

    Department of Housing and Urban Development — The CPD Allocation and Award database provides filterable on-screen and exportable reports on select programs, such as the Community Development Block Grant Program,...

  5. Documentation of Appliances & Interaction Devices

    DEFF Research Database (Denmark)

    2004-01-01

    The interaction devices and appliances explored in the WorkSPACE project, address spatial computing in the context of work. We have developed and explored a range of appliances and interaction devices. The scope has been to develop tools for support of collaboration by mixing digital and physical...

  6. Study on wall recycling behaviour in CPD spherical tokamak

    International Nuclear Information System (INIS)

    Bhattacharyay, R.; Zushi, H.; Hirooka, Y.; Sakamoto, M.; Yoshinaga, T.; Okamoto, K.; Kawasaki, S.; Hanada, K.; Sato, K.N.; Nakamura, K.; Idei, H.; Ryoukai, T.; Nakashima, H.; Higashijima, A.

    2008-01-01

    Experiments to study wall recycling behaviour have been performed in the small spherical tokamak compact plasma-wall interaction experimental device (CPD) from the viewpoint of global as well as local plasma wall interaction condition. Electron cyclotron resonance (ECR) plasma of typically ∼50 to 400 ms duration is produced using ∼40 to 80 kW RF power. In order to study the global wall recycling behaviour, pressure measurements are carried out just before and after the ECR plasma in the absence of any external pumping. The recycling behaviour is found to change from release to pumping beyond a certain level of pressure value which is again found to be a function of shot history. The real-time local wall behaviour is studied in similar RF plasma using a rotating tungsten limiter, actively coated with lithium. Measurement of H α light intensity in front of the rotating surface has indicated a clear reduction (∼10%) in the steady-state hydrogen recycling with continuous Li gettering of several minutes

  7. Poster: Virtual reality interaction using mobile devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-03-01

    In this work we aim to implement and evaluate alternative approaches for interacting with virtual environments on mobile devices for navigation, object selection and manipulation. Interaction with objects in virtual worlds using traditional input such as current state-of-the-art devices is often difficult and could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. We have developed new methods to perform different kinds of interactions using a mobile device (e.g. a smartphone) both as input device, performing selection and manipulation of objects, and as output device, utilizing the screen as an extra view (virtual camera or information display). Our hypothesis is that interaction via mobile devices facilitates simple tasks like the ones described within immersive virtual reality systems. We present here our initial implementation and result. © 2013 IEEE.

  8. High accessible experimental information on CPD experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, M. [RIAM, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan)], E-mail: hasegawa@triam.kyushu-u.ac.jp; Nakamura, K.; Higashijima, A.; Kawasaki, S.; Nakashima, H.; Sato, K.N.; Zushi, H.; Hanada, K.; Sakamoto, M.; Idei, H. [RIAM, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan)

    2008-04-15

    On CPD [1] (Compact PWI experimental Device) experiment, information of electronic logbook and sequence status are distributed by Web services to prepare future experimental environment such as steady state operation and remote participation. Hence, all the researchers can acquire information with a Web browser installed on a personal computer if they are connected to the Internet. However, to carry a notebook computer all the time is a burden to researchers. Furthermore, the researchers may not be always connected to the Internet. Mobile phones are superior in portability compared to notebook computers, and are easy to connect with Internet through the wireless network of the telecom carriers. Moreover, since recent mobile phones have full browsing function, their affinities to the Web services are becoming high. On this account, Web services for mobile phones are developed to access experimental information. For sequence monitoring, a mobile application MIDlet that utilizes special functions of mobile phone such as sound and vibration is also developed to draw attentions of researchers to sequence status.

  9. High accessible experimental information on CPD experiment

    International Nuclear Information System (INIS)

    Hasegawa, M.; Nakamura, K.; Higashijima, A.; Kawasaki, S.; Nakashima, H.; Sato, K.N.; Zushi, H.; Hanada, K.; Sakamoto, M.; Idei, H.

    2008-01-01

    On CPD [1] (Compact PWI experimental Device) experiment, information of electronic logbook and sequence status are distributed by Web services to prepare future experimental environment such as steady state operation and remote participation. Hence, all the researchers can acquire information with a Web browser installed on a personal computer if they are connected to the Internet. However, to carry a notebook computer all the time is a burden to researchers. Furthermore, the researchers may not be always connected to the Internet. Mobile phones are superior in portability compared to notebook computers, and are easy to connect with Internet through the wireless network of the telecom carriers. Moreover, since recent mobile phones have full browsing function, their affinities to the Web services are becoming high. On this account, Web services for mobile phones are developed to access experimental information. For sequence monitoring, a mobile application MIDlet that utilizes special functions of mobile phone such as sound and vibration is also developed to draw attentions of researchers to sequence status

  10. Virtual Reality Interaction Using Mobile Devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-07-01

    With the use of an immersive display system such as CAVE system, the user is able to realize a 3D immersive virtual environment realistically. However, interacting with virtual worlds in CAVE systems using traditional input devices to perform easy operations such as manipulation, object selection, and navigation is often difficult. This difficulty could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. Our research aims to implement and evaluate alternative approaches of interaction with immersive virtual environments on mobile devices for manipulation and object selection tasks. As many researchers have noted, using a mobile device as an interaction device has a number of advantages, including built-in display, built-in control, and touch screen facility. These advantages facilitate simple tasks within immersive virtual environments. This research proposes new methods using mobile devices like Smart-phones to perform di↵erent kinds of interactions both as an input device, (e.g. performing selection and manipulation of objects) and as an output device (e.g. utilizing the screen as an extra view for a virtual camera or information display). Moreover, we developed a prototype system to demonstrate and informally evaluate these methods. The research conclusion suggests using mobile devices as a 3D-controller. This will be a more intuitive approach to interact within the virtual environment.

  11. Poster: Virtual reality interaction using mobile devices

    KAUST Repository

    Aseeri, Sahar A.; Acevedo-Feliz, Daniel; Schulze, Jü rgen P.

    2013-01-01

    such as current state-of-the-art devices is often difficult and could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. We have developed new methods to perform different kinds of interactions using a mobile device (e.g. a

  12. Mobile devices, interaction, and distraction

    DEFF Research Database (Denmark)

    Aagaard, Jesper

    2016-01-01

    at stake in such impaired social interaction include delayed responses, mechanical intonation, a motionless body, and a lack of eye contact. Appropriating developmental psychologist Daniel Stern’s terminology, it is suggested that this mismatch between the vitality of a person and his or her absently...

  13. Plasma surface interactions in controlled fusion devices

    International Nuclear Information System (INIS)

    Ghendrih, Ph.; Becoulet, M.; Costanzo, L.

    2000-07-01

    This report brings together all the contributions of EURATOM/CEA association to the 14. international conference on plasma surface interactions in controlled fusion devices. 24 papers are presented and they deal mainly with the ergodic divertor and the first wall of Tore-supra tokamak

  14. Plasma surface interactions in controlled fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Ghendrih, Ph.; Becoulet, M.; Costanzo, L. [and others

    2000-07-01

    This report brings together all the contributions of EURATOM/CEA association to the 14. international conference on plasma surface interactions in controlled fusion devices. 24 papers are presented and they deal mainly with the ergodic divertor and the first wall of Tore-supra tokamak.

  15. Building blocks for protein interaction devices

    Science.gov (United States)

    Grünberg, Raik; Ferrar, Tony S.; van der Sloot, Almer M.; Constante, Marco; Serrano, Luis

    2010-01-01

    Here, we propose a framework for the design of synthetic protein networks from modular protein–protein or protein–peptide interactions and provide a starter toolkit of protein building blocks. Our proof of concept experiments outline a general work flow for part–based protein systems engineering. We streamlined the iterative BioBrick cloning protocol and assembled 25 synthetic multidomain proteins each from seven standardized DNA fragments. A systematic screen revealed two main factors controlling protein expression in Escherichia coli: obstruction of translation initiation by mRNA secondary structure or toxicity of individual domains. Eventually, 13 proteins were purified for further characterization. Starting from well-established biotechnological tools, two general–purpose interaction input and two readout devices were built and characterized in vitro. Constitutive interaction input was achieved with a pair of synthetic leucine zippers. The second interaction was drug-controlled utilizing the rapamycin-induced binding of FRB(T2098L) to FKBP12. The interaction kinetics of both devices were analyzed by surface plasmon resonance. Readout was based on Förster resonance energy transfer between fluorescent proteins and was quantified for various combinations of input and output devices. Our results demonstrate the feasibility of parts-based protein synthetic biology. Additionally, we identify future challenges and limitations of modular design along with approaches to address them. PMID:20215443

  16. Interactive lectures: Clickers or personal devices?

    Science.gov (United States)

    Morrell, Lesley J; Joyce, Domino A

    2015-01-01

    Audience response systems ('clickers') are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost) can be overcome using students' personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using questionnaires, we compare student perceptions of clicker and smartphone based polling systems. We find that students prefer interactive lectures generally, but those that used their own device preferred those lectures over lectures using clickers. However, device users were more likely to report using their devices for other purposes (checking email, social media etc.) when they were available to answer polling questions. These students did not feel that this distracted them from the lecture, instead, concerns over the use of smartphones centred around increased battery usage and inclusivity for students without access to suitable technology. Our results suggest that students generally preferred to use their own devices over clickers, and that this may be a sensible way to overcome some of the limitations associated with clickers, although issues surrounding levels of distraction and the implications for retention and recall of information need further investigation.

  17. Microfluidic Devices for Studying Biomolecular Interactions

    Science.gov (United States)

    Wilson, Wilbur W.; Garcia, Carlos d.; Henry, Charles S.

    2006-01-01

    Microfluidic devices for monitoring biomolecular interactions have been invented. These devices are basically highly miniaturized liquid-chromatography columns. They are intended to be prototypes of miniature analytical devices of the laboratory on a chip type that could be fabricated rapidly and inexpensively and that, because of their small sizes, would yield analytical results from very small amounts of expensive analytes (typically, proteins). Other advantages to be gained by this scaling down of liquid-chromatography columns may include increases in resolution and speed, decreases in the consumption of reagents, and the possibility of performing multiple simultaneous and highly integrated analyses by use of multiple devices of this type, each possibly containing multiple parallel analytical microchannels. The principle of operation is the same as that of a macroscopic liquid-chromatography column: The column is a channel packed with particles, upon which are immobilized molecules of the protein of interest (or one of the proteins of interest if there are more than one). Starting at a known time, a solution or suspension containing molecules of the protein or other substance of interest is pumped into the channel at its inlet. The liquid emerging from the outlet of the channel is monitored to detect the molecules of the dissolved or suspended substance(s). The time that it takes these molecules to flow from the inlet to the outlet is a measure of the degree of interaction between the immobilized and the dissolved or suspended molecules. Depending on the precise natures of the molecules, this measure can be used for diverse purposes: examples include screening for solution conditions that favor crystallization of proteins, screening for interactions between drugs and proteins, and determining the functions of biomolecules.

  18. The uptake of Continuing Professional Development (CPD) by Ghanaian radiographers

    International Nuclear Information System (INIS)

    Gawugah, James N.K.; Jadva-Patel, Hansa; Jackson, Marcus T.

    2011-01-01

    Continuing professional development (CPD) currently gains a priority within healthcare professions all over the globe. It is playing important roles in achieving improved quality care delivery. Healthcare practitioners are expected to continuously undertake CPD to maintain, enhance and improve quality of service delivery to meet the consumers' expectations. CPD offers practitioners the opportunity to retain and enhance the basic knowledge and skills through their working life; thus enhancing competency within one's professional range of practice. In Ghana, awareness of CPD participation has not been created among healthcare practitioners to enable them engage in effective CPD activities in order to improve their knowledge and skills. Purpose: To examine the level of radiographers' participation in CPD activities in Ghana. Method: A 21-item questionnaire was constructed to collect data from 80 participants drawn from among radiographers currently practising in the radiology/X-ray departments of the ten regional hospitals in Ghana. The questionnaire comprised of 3 sections: demographics, CPD and education specific sections. Out of 80 questionnaires administered, 42 were completed and returned representing 52.5%. Out of the percentage, 74% were males and 26% females. The findings highlight that majority (44%) of the participants are currently within the age group of 31-40 years, while 2% is/are 60 or more years. The article also reveals that the radiographers have access to few peer review journals which serve as sources of information on contemporary issues in radiography and CPD learning activities. Again, a generally poor level of CPD awareness among the Ghanaian radiographers has been established. Lack of effective recording of learning and CPD activities have also been revealed. Conclusion: The article concludes by recommending CPD policy guidelines; a regulatory body to register all healthcare professionals under one body to ensure effective CPD participation by

  19. Plasma Surface interaction in Controlled fusion devices

    International Nuclear Information System (INIS)

    1990-05-01

    The subjects presented in the 9th conference on plasma surface interaction in controlled fusion devices were: the modifications of power scrape-off-length and power deposition during various configurations in Tore Supra plasmas; the effects observed in ergodic divertor experiments in Tore-Supra; the diffuse connexion induced by the ergodic divertor and the topology of the heat load patterns on the plasma facing components in Tore-Supra; the study of the influence of air exposure on graphite implanted by low energy high density deuterium plasma

  20. Modelling dynamic human-device interaction in healthcare

    OpenAIRE

    Niezen, Gerrit

    2013-01-01

    Errors are typically blamed on human factors, forgetting that the system should have been designed to take them into account and minimise these problems. In our research we are developing tools to design interactive medical devices using human-in-the-loop modelling. Manual control theory is used to describe and analyse the dynamic aspects of human-device interaction.

  1. CPD Cross-Program Funding Matrix and Dashboard

    Data.gov (United States)

    Department of Housing and Urban Development — These matrices and dashboards provide funding information for each city and state that receives CPD Program funds, in a place-based format. The reports detail the...

  2. CPD Aligned to Competency Standards to Support Quality Practice

    Directory of Open Access Journals (Sweden)

    Rose Nash

    2017-02-01

    Full Text Available As medication experts, pharmacists are key members of the patient’s healthcare team. Pharmacists must maintain their competence to practice to remain responsive to the increasingly complex healthcare sector. This paper seeks to determine how competence training for pharmacists may enhance quality in their professional development. Results of two separately administered surveys (2012 and 2013 were compared to examine the reported continued professional development (CPD practices of Australian pharmacists. Examination of results from both studies enabled a focus on how the competency standards inform CPD practice.In the survey administered in 2012, 91% (n = 253/278 pharmacists reported that they knew their current registration requirements. However, in the survey administered in 2013, only 43% (n = 46/107 reported utilization of the National Competency Standards Framework for Pharmacists in Australia (NCS to self-asses their practice as part of their annual re-registration requirements. Fewer, 23% (n = 25/107, used the NCS to plan their CPD. This may be symptomatic of poor familiarity with the NCS, uncertainty around undertaking self-directed learning as part of a structured learning plan and/or misunderstandings around what CPD should include. This is supported by thematic analysis of pharmacists’ social media comments. Initial and ongoing competence training to support meaningful CPD requires urgent attention in Australia. The competence (knowledge, skills and attributes required to engage in meaningful CPD practice should be introduced and developed prior to entry into practice; other countries may find they are in a similar position.

  3. What Is "Effective" CPD for Contemporary Physical Education Teachers? A Deweyan Framework

    Science.gov (United States)

    Armour, Kathleen; Quennerstedt, Mikael; Chambers, Fiona; Makopoulou, Kyriaki

    2017-01-01

    It is widely argued that continuing professional development (CPD) for physical education (PE) teachers is important, yet questions remain about "effective" CPD. We consider these questions afresh from a Deweyan perspective. An overview of the CPD/PE-CPD literature reveals conflicting positions on teachers as learners. Considering the…

  4. CLASSROOM OBSERVATION- A POWERFUL TOOL FOR CONTINUOUS PROFESSIONAL DEVELOPMENT (CPD

    Directory of Open Access Journals (Sweden)

    Shanjida Halim

    2018-05-01

    Full Text Available For making teaching and learning more visible, classroom observation plays a central role. It provides teachers with constructive critical feedback in order to improve their classroom management and instructional techniques. For teachers it is important to observe the interaction between teacher-learner within the classroom because it can determine the learning opportunities that students get. Not only that, classroom observation encourages colleagues to collaborate to improve teacher practice and student learning. Feedback from classroom observations is an effective way for providing teachers with the information they need about their classroom behavior, and it can help them in their continuous professional development (CPD. This paper is based upon a practical approach to professional development among teachers through classroom observation. Since we, as teachers, are not born with innate teaching abilities, in fact, we learn and develop gradually with the help of some practical approaches, and classroom observation is a well-known powerful practical approach in primary and higher education to help teachers improve their teaching quality. This article mainly highlights the importance of classroom observation and its guidelines adapted from Observing Classes-CETaL. Further, it emphasizes the limitations of classroom observation, and suggests the ways to carry it out effectively based upon Observing Classes CETaL Model.

  5. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  6. Large Display Interaction Using Mobile Devices

    OpenAIRE

    Bauer, Jens

    2015-01-01

    Large displays become more and more popular, due to dropping prices. Their size and high resolution leverages collaboration and they are capable of dis- playing even large datasets in one view. This becomes even more interesting as the number of big data applications increases. The increased screen size and other properties of large displays pose new challenges to the Human- Computer-Interaction with these screens. This includes issues such as limited scalability to the number of users, diver...

  7. Designing Gestural Interfaces Touchscreens and Interactive Devices

    CERN Document Server

    Saffer, Dan

    2008-01-01

    If you want to get started in new era of interaction design, this is the reference you need. Packed with informative illustrations and photos, Designing Gestural Interfaces provides you with essential information about kinesiology, sensors, ergonomics, physical computing, touchscreen technology, and new interface patterns -- information you need to augment your existing skills in traditional" websites, software, or product development. This book will help you enter this new world of possibilities."

  8. Collaborative CPD and inquiry-based science in the classroom

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund

    on the teaching of science and on collaboration. Qualitative data obtained by following the same teacher teaching Science & Technology from 4th to 6th grade are used to discuss changes in her classroom practice; in particular concerning inquiry-based methods shown in earlier QUEST-research to be understood......Continuous Professional Development (CPD) is crucial for reforming science teaching, but more knowledge is needed about how to embed CPD in teachers’ daily work. The Danish QUEST-project is a long-term collaborative CPD-project designed informed by research and with activities changing rhythmically...... between seminars, individual trials in own classroom, and collaborative activities in the science-team at local schools. The QUEST research is aimed at understanding the relation between individual and social changes. In this study, quantitative data are used to compare the perceived effect from QUEST...

  9. Creative Science Teaching Labs: New Dimensions in CPD

    Science.gov (United States)

    Chappell, Kerry; Craft, Anna

    2009-01-01

    This paper offers analysis and evaluation of "Creative Science Teaching (CST) Labs III", a unique and immersive approach to science teachers' continuing professional development (CPD) designed and run by a London-based organisation, Performing Arts Labs (PAL), involving specialists from the arts, science and technology as integral. Articulating…

  10. CPD - The learning preferences of general practitioners | Van den ...

    African Journals Online (AJOL)

    Introduction: General Practitioners need to stay up to date and to maintain professional competence. The Health Professions Council of SA has introduced a mandatory recertification system starting in 1999. Insufficient research exists locally to reliably identify the continuing professional development (CPD) habits of GP's in ...

  11. Mobile devices and computing cloud resources allocation for interactive applications

    Directory of Open Access Journals (Sweden)

    Krawczyk Henryk

    2017-06-01

    Full Text Available Using mobile devices such as smartphones or iPads for various interactive applications is currently very common. In the case of complex applications, e.g. chess games, the capabilities of these devices are insufficient to run the application in real time. One of the solutions is to use cloud computing. However, there is an optimization problem of mobile device and cloud resources allocation. An iterative heuristic algorithm for application distribution is proposed. The algorithm minimizes the energy cost of application execution with constrained execution time.

  12. Optical Near-field Interactions and Forces for Optoelectronic Devices

    Science.gov (United States)

    Kohoutek, John Michael

    Throughout history, as a particle view of the universe began to take shape, scientists began to realize that these particles were attracted to each other and hence came up with theories, both analytical and empirical in nature, to explain their interaction. The interaction pair potential (empirical) and electromagnetics (analytical) theories, both help to explain not only the interaction between the basic constituents of matter, such as atoms and molecules, but also between macroscopic objects, such as two surfaces in close proximity. The electrostatic force, optical force, and Casimir force can be categorized as such forces. A surface plasmon (SP) is a collective motion of electrons generated by light at the interface between two mediums of opposite signs of dielectric susceptibility (e.g. metal and dielectric). Recently, surface plasmon resonance (SPR) has been exploited in many areas through the use of tiny antennas that work on similar principles as radio frequency (RF) antennas in optoelectronic devices. These antennas can produce a very high gradient in the electric field thereby leading to an optical force, similar in concept to the surface forces discussed above. The Atomic Force Microscope (AFM) was introduced in the 1980s at IBM. Here we report on its uses in measuring these aforementioned forces and fields, as well as actively modulating and manipulating multiple optoelectronic devices. We have shown that it is possible to change the far field radiation pattern of an optical antenna-integrated device through modification of the near-field of the device. This modification is possible through change of the local refractive index or reflectivity of the "hot spot" of the device, either mechanically or optically. Finally, we have shown how a mechanically active device can be used to detect light with high gain and low noise at room temperature. It is the aim of several of these integrated and future devices to be used for applications in molecular sensing

  13. Accounting Professionals and CPD: Attitudes and Engagement--Some Survey Evidence

    Science.gov (United States)

    Rothwell, Andrew; Herbert, Ian

    2007-01-01

    Continuing Professional Development (CPD) is a major issue in post-compulsory education at the start of the twenty-first century. This paper reports the results of a recent survey of accountancy members which explored attitudes towards CPD in relation to employability, career success and professional identity. Attitudes to CPD are chiefly…

  14. Immersive Live Event Experiences - Interactive UHDTV on Mobile Devices

    NARCIS (Netherlands)

    Niamut, O.A.; Thomas, G.A.; Thomas, E.D.R.; Brandenburg, R. van; D’Acunto, L.; Gregory-Clarke, R.

    2014-01-01

    This paper reports on the latest developments around tiled streaming. As an extension of HTTP adaptive streaming, it retains all the benefits of this streaming technology, while adding the possibility of interaction when consuming UHDTV on mobile devices. In particular, we discuss the underlying

  15. Live event experiences - Interactive UHDTV on mobile devices

    NARCIS (Netherlands)

    Niamut, O.A.; Thomas, G.A.; Thomas, E.D.R.; Brandenburg, R. van; D'Acunto, L.; Gregory-Clarke, R.

    2014-01-01

    This paper reports on the latest developments in tiled streaming. As an extension of HTTP adaptive streaming, it retains all the benefits of this streaming technology, while adding the potential of interaction when UHDTV is consumed on mobile devices. In particular, we discuss the underlying

  16. Device interactions in reducing the cost of tidal stream energy

    International Nuclear Information System (INIS)

    Vazquez, A.; Iglesias, G.

    2015-01-01

    Highlights: • Numerical modelling is used to estimate the levelised cost of tidal stream energy. • As a case study, a model of Lynmouth (UK) is implemented and successfully validated. • The resolution of the model allows the demarcation of individual devices on the model grid. • Device interactions reduce the available tidal resource and the cost increases significantly. - Abstract: The levelised cost of energy takes into account the lifetime generated energy and the costs associated with a project. The objective of this work is to investigate the effects of device interactions on the energy output and, therefore, on the levelised cost of energy of a tidal stream project, by means of numerical modelling. For this purpose, a case study is considered: Lynmouth (North Devon, UK), an area in the Bristol Channel in which the first tidal stream turbine was installed − a testimony of its potential as a tidal energy site. A state-of-the-art hydrodynamics model is implemented on a high-resolution computational grid, which allows the demarcation of the individual devices. The modification to the energy output resulting from interaction between turbines within the tidal farm is thus resolved for each individual turbine. The results indicate that significant changes in the levelised cost of energy values, of up to £0.221 kW h −1 , occur due to the aforementioned modifications, which should not be disregarded if the cost of tidal stream energy is to be minimised

  17. Radiographers attitudes to mandatory CPD: a comparative study in the United Kingdom and New Zealand

    International Nuclear Information System (INIS)

    Henwood, S.M.; Yielder, J.; Flinton, D.

    2004-01-01

    This study explores the attitudes of radiographers in two countries (UK and New Zealand) to mandatory CPD prior to a mandatory CPD policy being implemented. Postal questionnaires were sent to 1739 radiographers (250 in the UK and 1489 in New Zealand), in collaboration with the respective professional bodies in both countries. The study showed that there is a general ambivalent attitude towards CPD and there are a number of barriers which individuals identify to explain relatively low rates of participation in CPD. The study also showed that there is a very restricted view of what constitutes CPD around attendance at study days and formal activities and subsequently less formal activities are not being recognised and valued. The lack of recording of CPD activity was highlighted along with problems related to poor staffing levels and in places, lack of employer support. The study will be repeated and attitudes compared two years following the implementation of the mandatory CPD policy in both countries

  18. Contaminating fibrin in CPD-blood: solubility in plasma and distribution in blood components following separation

    International Nuclear Information System (INIS)

    Skjonsberg, O.H.; Kierulf, P.; Gravem, K.; Fagerhol, M.K.; Godal, H.C.

    1986-01-01

    In order to estimate the solubility of contaminating fibrin in CPD-blood, thrombin induced fibrin polymerzation in CPD-plasma was examined by light scattering and fibrinopeptide A (FPA) determinations. In addition, I-125 fibrin monomer enriched CPD-blood was used to investigate fibrin monomer retention in blood bags and transfusion filters (170 microns) and fibrin distribution in blood components derived from CPD-blood. Initial fibrin polymerization in CPD-blood occurred after conversion of 15 per cent of the fibrinogen to fibrin, implying that substantial amounts of fibrin may be kept solubilized in CPD-blood bags. Only minor amounts of I-125 fibrin monomers were retained in blood bags (2.4 per cent) and in transfusion filters (2.9 per cent) after sham transfusions. After separating I-125-fibrin monomer enriched CPD-blood into its constituent components, the major part of fibrin (75.0 per cent) could be traced in the cryoprecipitate

  19. Investigating Cross-Device Interaction between a Handheld Device and a Large Display

    DEFF Research Database (Denmark)

    Paay, Jeni; Raptis, Dimitrios; Kjeldskov, Jesper

    2017-01-01

    and mid-air gestures, pinching, swiping, swinging and flicking. We look specifically at their relative efficiency, effectiveness and accuracy in bi-directional interaction between a smartphone and large display in a point-click context. We report findings from two user studies, which show that swiping...... is both most effective, fastest and most accurate, closely followed by swinging. What these two approaches have in common is the ability to keep the pointer steady on the large display, unaffected by concurrent gestures or body movements used to complete the interaction, suggesting...... that this is an important factor for designing effective cross-device interaction with large displays....

  20. Educational CPD: how UK GP trainers develop themselves as teachers.

    Science.gov (United States)

    Waters, Mark; Wall, David

    2007-09-01

    There is little in the literature giving the perspective of UK General Practice (GP) trainers on their development as teachers. What motivates GP trainers develop themselves as teachers? What obstacles to their professional development do GP trainers perceive? A questionnaire to all GP trainers in the West Midlands Deanery in 2004. 360/444 (81%) questionnaires were returned. 56.6% of GP trainers had another educational role in addition to training GP Registrars in the practice. 15.8% of trainers possessed an educational qualification. 13 had completed a Certificate in Medical Education and 28 were engaged in study towards that qualification. Trainers wanted more time to spend on their development as teachers than they presently have, and would then be interested in a wider variety of learning methods. However, 56.6% of trainers would still not choose to undertake a university-accredited course. Female GP trainers perceived more difficulty in obtaining protected time for their development as teachers (Educational CPD) (p = 0.021), were significantly less sure of their partners' support for this development (p = 0.033), and were more likely to agree with trainers undertaking a Certificate in Medical Education (p = 0.003). Having an additional educational role did not affect trainers' ability to take protected time, but significantly increased the amount of time aspired to (p = 0.005). Nothing made more difference to trainers' perception of their ability to undertake Educational CPD than did the perceived attitude of their partners. Educational CPD was very important to GP trainers, but getting protected time was difficult. Consideration of the needs and opinions of partners was a very strong barrier to trainers taking sufficient protected time. Given more available time, GP trainers would be more likely to consider gaining academic qualifications in education. However, this was not be something that all trainers wanted.

  1. Wearable Vibrotactile Haptic Device for Stiffness Discrimination during Virtual Interactions

    Directory of Open Access Journals (Sweden)

    Andualem Tadesse Maereg

    2017-09-01

    Full Text Available In this paper, we discuss the development of cost effective, wireless, and wearable vibrotactile haptic device for stiffness perception during an interaction with virtual objects. Our experimental setup consists of haptic device with five vibrotactile actuators, virtual reality environment tailored in Unity 3D integrating the Oculus Rift Head Mounted Display (HMD and the Leap Motion controller. The virtual environment is able to capture touch inputs from users. Interaction forces are then rendered at 500 Hz and fed back to the wearable setup stimulating fingertips with ERM vibrotactile actuators. Amplitude and frequency of vibrations are modulated proportionally to the interaction force to simulate the stiffness of a virtual object. A quantitative and qualitative study is done to compare the discrimination of stiffness on virtual linear spring in three sensory modalities: visual only feedback, tactile only feedback, and their combination. A common psychophysics method called the Two Alternative Forced Choice (2AFC approach is used for quantitative analysis using Just Noticeable Difference (JND and Weber Fractions (WF. According to the psychometric experiment result, average Weber fraction values of 0.39 for visual only feedback was improved to 0.25 by adding the tactile feedback.

  2. Nomad devices for interactions in immersive virtual environments

    Science.gov (United States)

    George, Paul; Kemeny, Andras; Merienne, Frédéric; Chardonnet, Jean-Rémy; Thouvenin, Indira Mouttapa; Posselt, Javier; Icart, Emmanuel

    2013-03-01

    Renault is currently setting up a new CAVE™, a 5 rear-projected wall virtual reality room with a combined 3D resolution of 100 Mpixels, distributed over sixteen 4k projectors and two 2k projector as well as an additional 3D HD collaborative powerwall. Renault's CAVE™ aims at answering needs of the various vehicle conception steps [1]. Starting from vehicle Design, through the subsequent Engineering steps, Ergonomic evaluation and perceived quality control, Renault has built up a list of use-cases and carried out an early software evaluation in the four sided CAVE™ of Institute Image, called MOVE. One goal of the project is to study interactions in a CAVE™, especially with nomad devices such as IPhone or IPad to manipulate virtual objects and to develop visualization possibilities. Inspired by nomad devices current uses (multi-touch gestures, IPhone UI look'n'feel and AR applications), we have implemented an early feature set taking advantage of these popular input devices. In this paper, we present its performance through measurement data collected in our test platform, a 4-sided homemade low-cost virtual reality room, powered by ultra-short-range and standard HD home projectors.

  3. Continuing professional development (CPD) in radiography: A collaborative European meta-ethnography literature review

    International Nuclear Information System (INIS)

    Wareing, A.; Buissink, C.; Harper, D.; Gellert Olesen, M.; Soto, M.; Braico, S.; Van Laer, P.; Gremion, I.; Rainford, L.

    2017-01-01

    Objectives: The aim of the study was to complete a collaborative review of Radiography continuing professional development (CPD) research material to support the production of European Federation of Radiographer Societies (EFRS) CPD recommendations. A meta-ethnography approach to literature review was applied focussing upon commonalities rather than discrepancies between research outcomes. This facilitated exploration of context across the geographical region of Europe with national variations in CPD governance. The seven phases of the meta-ethnographic approach were followed by two independent experienced researchers. A third researcher mediated the findings which were then explored collaboratively with the EFRS CPD working group for concordance. Key Findings: Phase seven of the meta-ethnography involved interpreting an expression of the synthesis from the previous stages. Six main corroborating themes emerged in this process and following mediation were expressed as themes; knowledge, skills & competency, needs/gap analysis, multi-layered/multi-modal, barriers and drivers; regulation vs autonomy; fostering collaboration – harnessing technology. Conclusion: The primary feature of CPD activity should be the resulting impact – to patients, the service, the profession and the individual; with all stakeholders working in partnership. CPD activity must be flexible/multi-modal to support the changing growth/dynamic workforce. All stakeholders should utilise communication and technology resources and make efforts to improve collaboration between the management, regulators and educators to support Radiographers to develop meaningful CPD. Health services across Europe are under increasing stress and a principal factor going forwards will be managing increasing demands on healthcare staff whilst supporting enhancement of the knowledge, skills and competency base. - Highlights: • CPD should have impact to patients, the service, the profession and the individual.

  4. Cross-Surface: Workshop on Interacting with Multi-Device Ecologies in the Wild

    DEFF Research Database (Denmark)

    Houben, Steven; Vermeulen, Jo; Klokmose, Clemens Nylandsted

    2015-01-01

    In this workshop, we will review and discuss opportunities, technical challenges and problems with cross-device interactions in interactive multi-surface and multi-device ecologies. We aim to bring together researchers and practitioners currently working on novel techniques for cross......-surface interactions, identify application domains and enabling technologies for cross-surface interactions in the wild, and establish a research community to develop effective strategies for successful design of cross-device interactions....

  5. The CPD Needs of Mentors in Post-Compulsory Initial Teacher Training in England

    Science.gov (United States)

    Ingleby, Ewan; Hunt, John

    2008-01-01

    This paper discusses the compulsory professional development (CPD) needs of mentors within post-compulsory Initial Teacher Training (ITT) provision in England. The discussion applies the ideas of Weber, Foucault, Habermas and Bourdieu in interpreting the implications for post-compulsory ITT mentor CPD training. The paper's primary and secondary…

  6. Evaluating Online CPD Using Educational Criteria Derived from the Experiential Learning Cycle.

    Science.gov (United States)

    Friedman, Andrew; Watts, David; Croston, Judith; Durkin, Catherine

    2002-01-01

    Develops a set of educational evaluation criteria for online continuing professional development (CPD) courses using Kolb's experiential learning cycle theory. Evaluates five courses provided by online CPD Web sites, concludes that these online courses neglect parts of the learning cycle, and suggests improvements. (Author/LRW)

  7. Australian Rural Accountants' Views on How Locally Provided CPD Compares with City-Based Provision

    Science.gov (United States)

    Halabi, Abdel K.

    2015-01-01

    This paper analyses Australian rural accountants' attitudes and levels of satisfaction with continuing professional development (CPD), based on whether the CPD was delivered by a professional accounting body in a rural or metropolitan area. The paper responds to prior research that finds rural accountants are dissatisfied with professional…

  8. Continuing professional development across the nursing career : A lifespan perspective on CPD motives and learning activities

    NARCIS (Netherlands)

    Pool, I.A.

    2015-01-01

    There is a growing consensus that pre-registration nursing education is just the start of learning that continues throughout a nursing career. Within the context of rapidly changing patient care continuing professional development (CPD) is crucial. The increased emphasis on CPD coincides with an

  9. Guided-wave acousto-optics interactions, devices, and applications

    CERN Document Server

    1990-01-01

    The field of integrated- or guided-wave optics has experienced significant and continuous growth since its inception in the late 1960s. There has been a considerable increase in research and development activity in this field worldwide and some significant advances in the realization of working in­ tegrated optic devices and modules have been made in recent years. In fact, there have already been some commercial manufacturing and technical ap­ plications of such devices and modules. The guided-wave-acoustooptics involving Bragg interactions between guided optical waves and surface acoustic waves is one of the areas of in­ tegrated-optics that has reached some degree of scientific and technological maturity. This topical volume is devoted to an in-depth treatment of this emerging branch of science and technology. Presented in this volume are concise treatments on bulk-wave acoustooptics, guided-wave optics, and surface acoustic waves, and detailed studies of guided-wave acoustooptic Bragg diffraction in thr...

  10. Office of Community Planning and Development (CPD) Awards (2004-2017)

    Data.gov (United States)

    City and County of Durham, North Carolina — This data set provide full-year allocations at the local jurisdiction level for the Office of Community Planning and Development's (CPD) formula programs from...

  11. QUEST for sustainable CPD: scaffolding science teachers' individual and collaborative inquiries

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund

    2015-01-01

    Continuous Professional Development (CPD) can be crucial for reforming science teaching, but more knowledge is needed about how to support sustainability of the effects. The Danish QUEST project is a large scale, long-term collaborative CPD project designed according to widely agreed criteria...... phase. The findings are discussed looking forward to the institutionalization phase identifying factors potentially supporting sustainable development pertaining to local science teachers developing a shared focus on student learning in science, and perceived individual and collective efficacy...

  12. Attitudes to social media use as a platform for Continuing Professional Development (CPD) within occupational therapy

    OpenAIRE

    Murray, Kelly; Ward, Kath

    2017-01-01

    Introduction: This study explored what influences the use of social media platforms within the CPD of occupational therapy students and qualified occupational therapists. It also considered perceived barriers to its use and whether age in line with generation theory, in particular digital natives vs digital immigrants impacted on willingness to utilise social media within CPD.\\ud \\ud Method: A mixed method survey design was utilised to collect qualitative and quantitative data through an onli...

  13. Proceso de virtualización de un centro de procesamiento de datos (CPD)

    OpenAIRE

    Castro Santero, Juan

    2016-01-01

    Este trabajo trata del proceso de virtualización de un centro de procesamiento de datos (CPD), por el que se explica paso a paso este proceso. Aquest treball tracta del procés de virtualització d'un centre de processament de dades (CPD), pel que s'explica pas a pas aquest procés. Bachelor thesis for the Computer Science program.

  14. Interaction devices for hands-on desktop design

    Science.gov (United States)

    Ju, Wendy; Madsen, Sally; Fiene, Jonathan; Bolas, Mark T.; McDowall, Ian E.; Faste, Rolf

    2003-05-01

    Starting with a list of typical hand actions - such as touching or twisting - a collection of physical input device prototypes was created to study better ways of engaging the body and mind in the computer aided design process. These devices were interchangeably coupled with a graphics system to allow for rapid exploration of the interplay between the designer's intent, body motions, and the resulting on-screen design. User testing showed that a number of key considerations should influence the future development of such devices: coupling between the physical and virtual worlds, tactile feedback, and scale. It is hoped that these explorations contribute to the greater goal of creating user interface devices that increase the fluency, productivity and joy of computer-augmented design.

  15. Evaluation of Tissue Interactions with Mechanical Elements of a Transscleral Drug Delivery Device

    Directory of Open Access Journals (Sweden)

    Jeffrey T. Borenstein

    2012-03-01

    Full Text Available The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device—one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene (PTFE membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation.

  16. A point-based rendering approach for real-time interaction on mobile devices

    Institute of Scientific and Technical Information of China (English)

    LIANG XiaoHui; ZHAO QinPing; HE ZhiYing; XIE Ke; LIU YuBo

    2009-01-01

    Mobile device is an Important interactive platform. Due to the limitation of computation, memory, display area and energy, how to realize the efficient and real-time interaction of 3D models based on mobile devices is an important research topic. Considering features of mobile devices, this paper adopts remote rendering mode and point models, and then, proposes a transmission and rendering approach that could interact in real time. First, improved simplification algorithm based on MLS and display resolution of mobile devices is proposed. Then, a hierarchy selection of point models and a QoS transmission control strategy are given based on interest area of operator, interest degree of object in the virtual environment and rendering error. They can save the energy consumption. Finally, the rendering and interaction of point models are completed on mobile devices. The experiments show that our method is efficient.

  17. Continuing professional development (CPD) in radiography: A collaborative European meta-ethnography literature review.

    Science.gov (United States)

    Wareing, A; Buissink, C; Harper, D; Gellert Olesen, M; Soto, M; Braico, S; Van Laer, P; Gremion, I; Rainford, L

    2017-09-01

    The aim of the study was to complete a collaborative review of Radiography continuing professional development (CPD) research material to support the production of European Federation of Radiographer Societies (EFRS) CPD recommendations. A meta-ethnography approach to literature review was applied focussing upon commonalities rather than discrepancies between research outcomes. This facilitated exploration of context across the geographical region of Europe with national variations in CPD governance. The seven phases of the meta-ethnographic approach were followed by two independent experienced researchers. A third researcher mediated the findings which were then explored collaboratively with the EFRS CPD working group for concordance. Phase seven of the meta-ethnography involved interpreting an expression of the synthesis from the previous stages. Six main corroborating themes emerged in this process and following mediation were expressed as themes; knowledge, skills & competency, needs/gap analysis, multi-layered/multi-modal, barriers and drivers; regulation vs autonomy; fostering collaboration - harnessing technology. The primary feature of CPD activity should be the resulting impact - to patients, the service, the profession and the individual; with all stakeholders working in partnership. CPD activity must be flexible/multi-modal to support the changing growth/dynamic workforce. All stakeholders should utilise communication and technology resources and make efforts to improve collaboration between the management, regulators and educators to support Radiographers to develop meaningful CPD. Health services across Europe are under increasing stress and a principal factor going forwards will be managing increasing demands on healthcare staff whilst supporting enhancement of the knowledge, skills and competency base. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  18. The environmental interactions of tidal and wave energy generation devices

    International Nuclear Information System (INIS)

    Frid, Chris; Andonegi, Eider; Depestele, Jochen; Judd, Adrian; Rihan, Dominic; Rogers, Stuart I.; Kenchington, Ellen

    2012-01-01

    Global energy demand continues to grow and tidal and wave energy generation devices can provide a significant source of renewable energy. Technological developments in offshore engineering and the rising cost of traditional energy means that offshore energy resources will be economic in the next few years. While there is now a growing body of data on the ecological impacts of offshore wind farms, the scientific basis on which to make informed decisions about the environmental effects of other offshore energy developments is lacking. Tidal barrages have the potential to cause significant ecological impacts particularly on bird feeding areas when they are constructed at coastal estuaries or bays. Offshore tidal stream energy and wave energy collectors offer the scope for developments at varying scales. They also have the potential to alter habitats. A diversity of designs exist, including floating, mid-water column and seabed mounted devices, with a variety of moving-part configurations resulting in a unique complex of potential environmental effects for each device type, which are discussed to the extent possible. - Highlights: ► We review the environmental impacts of tidal barrages and fences, tidal stream farms and wave energy capture devices. ► Impacts on habitats, species and the water column, and effects of noise and electromagnetic fields are considered. ► Tidal barrages can cause significant impacts on bird feeding areas when constructed at coastal estuaries or bays. ► Wave energy collectors can alter water column and sea bed habitats locally and over large distances.

  19. Human Handheld-Device Interaction : An Adaptive User Interface

    NARCIS (Netherlands)

    Fitrianie, S.

    2010-01-01

    The move to smaller, lighter and more powerful (mobile) handheld devices, whe-ther PDAs or smart-phones, looks like a trend that is building up speed. With numerous embedded technologies and wireless connectivity, the drift opens up unlimited opportunities in daily activities that are both more

  20. The environmental interactions of tidal and wave energy generation devices

    OpenAIRE

    Frid, C.; Andonegi, E.; Depestele, J.; Judd, A.; Rihan, D.; Rogers, S.I.; Kenchington, E.

    2012-01-01

    Global energy demand continues to grow and tidal and wave energy generation devices can provide a significant source of renewable energy. Technological developments in offshore engineering and the rising cost of traditional energy means that offshore energy resources will be economic in the next few years. While there is now a growing body of data on the ecological impacts of offshore wind farms, the scientific basis on which to make informed decisions about the environmental effects of other...

  1. The environmental interactions of tidal and wave energy generation devices

    Energy Technology Data Exchange (ETDEWEB)

    Frid, Chris, E-mail: c.l.j.frid@liv.ac.uk [School of Environmental Sciences, University of Liverpool, Crown Street, Liverpool, L69 7ZB (United Kingdom); Andonegi, Eider, E-mail: eandonegi@azti.es [AZTI-Tecnalia, Txatxarramendi ugartea, z/g E-48395 Sukarrieta (Bizkaia) (Spain); Depestele, Jochen, E-mail: jochen.depestele@ilvo.vlaanderen.be [Institute for Agricultural and Fisheries Research, Ankerstraat 1, B-8400 Oostende (Belgium); Judd, Adrian, E-mail: Adrian.Judd@cefas.co.uk [Centre for Environment, Fisheries and Aquaculture Science , Lowestoft Laboratory, Pakefield Road, Lowestoft NR33 0HT United Kingdom (United Kingdom); Rihan, Dominic, E-mail: Dominic.RIHAN@ec.europa.eu [Irish Sea Fisheries Board, P.O. Box 12 Dun Laoghaire, Co. Dublin (Ireland); Rogers, Stuart I., E-mail: stuart.rogers@cefas.co.uk [Centre for Environment, Fisheries and Aquaculture Science , Lowestoft Laboratory, Pakefield Road, Lowestoft NR33 0HT United Kingdom (United Kingdom); Kenchington, Ellen, E-mail: Ellen.Kenchington@dfo-mpo.gc.ca [Fisheries and Oceans Canada, Bedford Institute of Oceanography, P.O. Box 1006, Dartmouth Canada, NS B2Y 4A2 (Canada)

    2012-01-15

    Global energy demand continues to grow and tidal and wave energy generation devices can provide a significant source of renewable energy. Technological developments in offshore engineering and the rising cost of traditional energy means that offshore energy resources will be economic in the next few years. While there is now a growing body of data on the ecological impacts of offshore wind farms, the scientific basis on which to make informed decisions about the environmental effects of other offshore energy developments is lacking. Tidal barrages have the potential to cause significant ecological impacts particularly on bird feeding areas when they are constructed at coastal estuaries or bays. Offshore tidal stream energy and wave energy collectors offer the scope for developments at varying scales. They also have the potential to alter habitats. A diversity of designs exist, including floating, mid-water column and seabed mounted devices, with a variety of moving-part configurations resulting in a unique complex of potential environmental effects for each device type, which are discussed to the extent possible. - Highlights: Black-Right-Pointing-Pointer We review the environmental impacts of tidal barrages and fences, tidal stream farms and wave energy capture devices. Black-Right-Pointing-Pointer Impacts on habitats, species and the water column, and effects of noise and electromagnetic fields are considered. Black-Right-Pointing-Pointer Tidal barrages can cause significant impacts on bird feeding areas when constructed at coastal estuaries or bays. Black-Right-Pointing-Pointer Wave energy collectors can alter water column and sea bed habitats locally and over large distances.

  2. Physicians interrupted by mobile devices in hospitals: understanding the interaction between devices, roles, and duties.

    Science.gov (United States)

    Solvoll, Terje; Scholl, Jeremiah; Hartvigsen, Gunnar

    2013-03-07

    A common denominator of modern hospitals is a variety of communication problems. In particular, interruptions from mobile communication devices are a cause of great concern for many physicians. To characterize how interruptions from mobile devices disturb physicians in their daily work. The gathered knowledge will be subsequently used as input for the design and development of a context-sensitive communication system for mobile communications suitable for hospitals. This study adheres to an ethnographic and interpretive field research approach. The data gathering consisted of participant observations, non-structured and mostly ad hoc interviews, and open-ended discussions with a selected group of physicians. Eleven physicians were observed for a total of 135 hours during May and June 2009. The study demonstrates to what degree physicians are interrupted by mobile devices in their daily work and in which situations they are interrupted, such as surgery, examinations, and during patients/relatives high-importance level conversations. The participants in the study expected, and also indicated, that wireless phones probably led to more interruptions immediately after their introduction in a clinic, when compared to a pager, but this changed after a short while. The unpleasant feeling experienced by the caller when interrupting someone by calling them differs compared to sending a page message, which leaves it up to the receiver when to return the call. Mobile devices, which frequently interrupt physicians in hospitals, are a problem for both physicians and patients. The results from this study contribute to knowledge being used as input for designing and developing a prototype for a context-sensitive communication system for mobile communication suitable for hospitals. We combined these findings with results from earlier studies and also involved actual users to develop the prototype, CallMeSmart. This system intends to reduce such interruptions and at the same time

  3. Contributions to the 7th International Conference on plasma surface interactions in controlled fusion devices

    International Nuclear Information System (INIS)

    1986-01-01

    The report contains three papers presented in the 7th International Conference on plasma surface interactions in controlled fusion devices held in Princeton (USA) 5-9 May 1986, all referred to the FT Tokamak

  4. Maternal mobile device use during a structured parent-child interaction task.

    Science.gov (United States)

    Radesky, Jenny; Miller, Alison L; Rosenblum, Katherine L; Appugliese, Danielle; Kaciroti, Niko; Lumeng, Julie C

    2015-01-01

    To examine associations of maternal mobile device use with the frequency of mother-child interactions during a structured laboratory task. Participants included 225 low-income mother-child pairs. When children were ∼6 years old, dyads were videotaped during a standardized protocol in order to characterize how mothers and children interacted when asked to try familiar and unfamiliar foods. From videotapes, we dichotomized mothers on the basis of whether or not they spontaneously used a mobile device, and we counted maternal verbal and nonverbal prompts toward the child. We used multivariate Poisson regression to study associations of device use with eating prompt frequency for different foods. Mothers were an average of 31.3 (SD 7.1) years old, and 28.0% were of Hispanic/nonwhite race/ethnicity. During the protocol, 23.1% of mothers spontaneously used a mobile device. Device use was not associated with any maternal characteristics, including age, race/ethnicity, education, depressive symptoms, or parenting style. Mothers with device use initiated fewer verbal (relative rate 0.80; 95% confidence interval 0.63, 1.03) and nonverbal (0.61; 0.39, 0.96) interactions with their children than mothers who did not use a device, when averaged across all foods. This association was strongest during introduction of halva, the most unfamiliar food (0.67; 0.48, 0.93 for verbal and 0.42; 0.20, 0.89 for nonverbal interactions). Mobile device use was common and associated with fewer interactions with children during a structured interaction task, particularly nonverbal interactions and during introduction of an unfamiliar food. More research is needed to understand how device use affects parent-child engagement in naturalistic contexts. Copyright © 2015 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  5. Composing Interactive Dance Pieces for the MotionComposer, a device for Persons with Disabilities

    OpenAIRE

    Bergsland, Andreas; Wechsler, Robert

    2015-01-01

    The authors have developed a new hardware/software device for persons with disabilities (the MotionComposer), and in the process created a number of interactive dance pieces for non- disabled professional dancers. The paper briefly describes the hardware and motion tracking software of the device before going into more detail concerning the mapping strategies and sound design applied to three interactive dance pieces. The paper concludes by discussing a particular philosophy championing trans...

  6. Konsep Continuing Professional Development (CPD dalam Pengembangan Profesionalisme Pustakawan Universitas Negeri Semarang

    Directory of Open Access Journals (Sweden)

    M. Z. Eko Handoyo

    2016-09-01

    attention. The objective of the study is to find out the implementation of CPD concept in efforts to develop library profession at Semarang State University. Respondents consisted of 40 librarians, comprising those working at the main library (22 librarians and at the departemental or faculty libraries. The study used quantitative method the result showed that (1 the librarians were not yet familiar with CPD concept; (2 UNNES Library has not implemented CPD concept in developing its professional librarians, (3 UNNES has not had a clear policy commitment in developing its professional librarians, (4 Continuous efforts have to be made in order to develop professional librarians at UNNES with the support of the university leaders.

  7. Input Devices and Interaction Techniques for VR-Enhanced Medicine

    Science.gov (United States)

    Gallo, Luigi; Pietro, Giuseppe De

    Virtual Reality (VR) technologies make it possible to reproduce faithfully real life events in computer-generated scenarios. This approach has the potential to simplify the way people solve problems, since they can take advantage of their real life experiences while interacting in synthetic worlds.

  8. Configurable Input Devices for 3D Interaction using Optical Tracking

    NARCIS (Netherlands)

    A.J. van Rhijn (Arjen)

    2007-01-01

    textabstractThree-dimensional interaction with virtual objects is one of the aspects that needs to be addressed in order to increase the usability and usefulness of virtual reality. Human beings have difficulties understanding 3D spatial relationships and manipulating 3D user interfaces, which

  9. Configurable input devices for 3D interaction using optical tracking

    NARCIS (Netherlands)

    Rhijn, van A.J.

    2007-01-01

    Three-dimensional interaction with virtual objects is one of the aspects that needs to be addressed in order to increase the usability and usefulness of virtual reality. Human beings have difficulties understanding 3D spatial relationships and manipulating 3D user interfaces, which require the

  10. Investigating Cross-Device Interaction between a Handheld Device and a Large Display

    DEFF Research Database (Denmark)

    Paay, Jeni; Raptis, Dimitrios; Kjeldskov, Jesper

    2017-01-01

    and mid-air gestures, pinching, swiping, swinging and flicking. We look specifically at their relative efficiency, effectiveness and accuracy in bi-directional interaction between a smartphone and large display in a point-click context. We report findings from two user studies, which show that swiping...... is both most effective, fastest and most accurate, closely followed by swinging. What these two approaches have in common is the ability to keep the pointer steady on the large display, unaffected by concurrent gestures or body movements used to complete the interaction, suggesting...

  11. 3D interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Nobel-Jørgensen, Morten; Aage, Niels; Christiansen, Asger Nyman

    2015-01-01

    This educational paper describes the implementation aspects, user interface design considerations and workflow potential of the recently published TopOpt 3D App. The app solves the standard minimum compliance problem in 3D and allows the user to change design settings interactively at any point...... in time during the optimization. Apart from its educational nature, the app may point towards future ways of performing industrial design. Instead of the usual geometrize, then model and optimize approach, the geometry now automatically adapts to the varying boundary and loading conditions. The app...

  12. Cloud Interaction and Safety Features of Mobile Devices

    Directory of Open Access Journals (Sweden)

    Mirsat Yeşiltepe

    2018-02-01

    Full Text Available In this paper, two current popular mobile operating system, still in relation to the conceptof cloud began to supplant the internet almost Word today, the differences, the concept of cloudsecurity mechanisms they use for themselves and are dealt with in this environment. One ofcomparing mobile operation system is representing open source and the other for close source one.The other issue discussed in this article is how the mobile environment interacts with the cloud thanthe cloud communication with the computers.

  13. Tablet PC interaction with digital micromirror device (DMD)

    Science.gov (United States)

    Refai, Hakki H.; Dahshan, Mostafa H.; Sluss, James J., Jr.

    2007-02-01

    Digital light processing (DLP) is an innovative display technology that uses an optical switch array, known as a digital micromirror device (DMD), which allows digital control of light. To date, DMDs have been used primarily as high-speed spatial light modulators for projector applications. A tablet PC is a notebook or slate-shaped mobile PC. Its touch screen or digitizing tablet technology allows the user to operate the notebook with a stylus or digital pen instead of using a keyboard or mouse. In this paper, we describe an interface solution that translates any sketch on the tablet PC screen to an identical mirror-copy over the cross-section of the DMD micromirrors such that the image of the sketch can be projected onto a special screen. An algorithm has been created to control each single micromirror of the hundreds of thousands of micromirrors that cover the DMD surface. We demonstrate the successful application of a DMD to a high-speed two-dimensional (2D) scanning environment, acquiring the data from the tablet screen and launching its contents to the projection screen; with very high accuracy up to 13.68 μm x 13.68 μm of mirror pitch.

  14. An Exploratory Study to Measure Excessive Involvement in Multitasking Interaction with Smart Devices.

    Science.gov (United States)

    Zhang, Yubo; Rau, Pei-Luen Patrick

    2016-06-01

    This study developed a scale measuring excessive involvement in multitasking interaction with smart devices. An online questionnaire was designed and surveyed in a sample of 380 respondents. The sample was split into two groups for exploratory and confirmatory factor analysis, respectively. A four-factor structure was identified with an acceptable goodness of fit. The first two factors, "Obsession and neglect" and "Problematic control," described the obsessive feelings, neglect behaviors, and behavior control problems accompanied by excessive multitasking interaction with smart devices. The latter two factors, "Multitasking preference" and "Polychronic orientation," referred to multitaskers' preference of engaging in multiple media use or interaction tasks rather than a single task from the time orientation perspective. The four-factor structure indicates that excessive involvement in multitasking interaction with smart devices shares some similarities with other behavioral addiction types, but demonstrates uniqueness compared with excessive engagement in single media use.

  15. Tritium interactions with steel and construction materials in fusion devices

    International Nuclear Information System (INIS)

    Dickson, R.S.

    1990-11-01

    The literature on the interactions of tritium and tritiated water with metals, glasses, ceramics, concrete, paints, polymers and other organic materials is reviewed in this report Some of the processes affecting the amount of tritium found on various materials, such as permeation, sorption and the conversion of tritium found on various materials, such as permeation, sorption and conversion of elemental tritium (T 2 ) to tritiated water (HTO), are also briefly outlined. Tritium permeation in steels is fairly well understood, but effects of surface preparation and coatings on sorption are not yet clear. Permeation of T 2 into other metals with cleaned surfaces has been studied thoroughly at high temperature, and the effect of surface oxidation has also been explored. The room-temperature permeation rates of low-permeability metals with cleaned surfaces are much faster than indicated by high-temperature results, because of grain-boundary diffusion. Elastomers have been studied to a certain extent, but some mechanisms of interaction with tritium gas and sorbed tritium are unclear. Ceramics have some of the lowest sorption and permeation rates, but ceramic coatings on stainless steels do not lower permeation or tritium as effectively as coatings obtained by oxidation of the steel, probably because of cracking caused by differences in thermal expansion coefficient. Studies on concrete are in their early stages; they show that sorption of tritiated water on concrete is a major concern in cleanup of releases of elemental tritium into air in tritium handling facilities. Some of the codes for modelling releases and sorption of T 2 and HTO contain unproven assumptions about sorption and T 2 → HTO conversion. Several experimental programs will be required in order to clear up ambiguities in previous work and to determine parameters for materials which have not yet been investigated. (146 refs., tab.)

  16. 77 FR 74862 - OneCPD Technical Assistance and Capacity Building Needs Assessment

    Science.gov (United States)

    2012-12-18

    ... and group learning activities to benefit CPD grantees and subrecipients. Members of the affected... forms of information technology, e.g., permitting electronic submission of responses. This notice also... across grantees and assist in prioritizing the development of tools, products and group learning...

  17. Nanocomposite C-Pd thin films – a new material with specific spectral properties

    Directory of Open Access Journals (Sweden)

    M. Suchańska

    2013-09-01

    Full Text Available In this paper, the results of optical investigations for thin films of carbon-palladium (C-Pd nanocomposites are presented. This films were prepared using two steps method (PVD/ CVD. The optical and Raman spectroscopy has been used to characterize the material. The multinanolayer model was used to explain the specific spectral properties.

  18. Secure and Usable Out-Of-Band Channels for Ad Hoc Mobile Device Interactions

    OpenAIRE

    Kainda , Ronald; Flechais , Ivan; Roscoe , A. W.

    2010-01-01

    International audience; Protocols for bootstrapping security in ad hoc mobile device interactions rely on users' ability to perform specific tasks such as transferring or comparing fingerprints of information between devices. The size of fingerprints depends on the level of technical security required by a given application but, at the same time, is limited by users' inability to deal with large amounts of data with high levels of accuracy. Large fingerprints provide high technical security b...

  19. Feasibility Study of Interactive Game Technologies to Improve Experience with Inhaler Spacer Devices in Young Children

    OpenAIRE

    Aslam, Tariq; Shakir, Savana; Murray, Clare

    2016-01-01

    IntroductionThe correct use of inhaler devices with facemasks and spacers in young children can be difficult for both children and parents, resulting in distress for both, poor adherence and ineffective drug delivery. The aim of this study was to develop and assess the utility and impact of an interactive electronic game designed to improve the experience of spacer devices in young asthmatic children.MethodsThe Respiratory Aid For Inhaler (RAFIhaler) technology consists of a smartphone mounte...

  20. Haptics using a smart material for eyes-free interaction in personal devices

    Science.gov (United States)

    Wang, Huihui; Lane, William Brian; Pappas, Devin; Duque, Bryam; Leong, John

    2014-03-01

    In this paper we present a prototype using a dry ionic polymer metal composite (IPMC) in interactive personal devices such as bracelet, necklace, pocket key chain or mobile devices for haptic interaction when audio or visual feedback is not possible or practical. This prototype interface is an electro-mechanical system that realizes a shape-changing haptic display for information communication. A dry IPMC will change its dimensions due to the electrostatic effect when an electrical potential is provided to them. The IPMC can operate at a lower voltage (less than 2.5V) which is compatible with requirements for personal electrical devices or mobile devices. The prototype consists of the addressable arrays of the IPMCs with different dimensions which are deformable to different shapes with proper handling or customization. 3D printing technology will be used to form supporting parts. Microcontrollers (about 3cm square) from DigiKey will be imbedded into this personal device. An Android based mobile APP will be developed to talk with microcontrollers to control IPMCs. When personal devices receive information signals, the original shape of the prototype will change to another shape related to the specific sender or types of information sources. This interactive prototype can simultaneously realize multiple methods for conveying haptic information such as dimension, force, and texture due to the flexible array design. We conduct several studies of user experience to explore how users' respond to shape change information.

  1. Innovative Approaches to Continuous Professional Development (CPD) in Early Childhood Education and Care (ECEC) in Europe: Findings from a Comparative Review

    Science.gov (United States)

    Jensen, Bente; Iannone, Rosa Lisa

    2018-01-01

    This article explores innovation as an aspect of in-service continuous professional development (CPD) in ECEC. Based on a literature review and a cross-country analysis conducted in ten European countries, we found that innovation in CPD was understood as a way to improving quality in ECEC. CPD no longer solely deals with practitioners' knowledge…

  2. Australasian emergency physicians: a learning and educational needs analysis. Part Four: CPD topics desired by emergency physicians.

    Science.gov (United States)

    Dent, Andrew W; Weiland, Tracey J; Paltridge, Debbie

    2008-06-01

    To report the preferences of Fellows of the Australasian College for Emergency Medicine for topics they would desire for their continuing professional development (CPD). A mailed survey of Fellows of the Australasian College for Emergency Medicine asked for Likert type responses on the desirability of CPD on 15 procedural skills, 13 management skills, 11 clinical emergency topics, 9 topics related to teaching, 7 related to diagnostics and 5 evidence based practice topics. CPD in procedural skills of advanced and surgical airways, ED ultrasound, ventilation, skills, plastic procedures and regional anaesthesia were nominated as desirable by 85% of emergency physicians (EP). More than 90% desired CPD in ophthalmological, otorhinolaryngeal, neonatal and paediatric emergencies. Of diagnostic skills, more than 80% considered CPD on computerized tomography, electrocardiography and plain X-ray interpretation as desirable, well as CPD about teaching in general, simulation and preparing candidates for fellowship exams. Of the 12 management skills, 11 were seen as desirable topics by more than 70%, with counter disaster planning, giving feedback and dealing with complaints the most popular. All evidence based practice related skills, including interpreting statistics and undertaking literature searches were seen as desirable topics by more than 80% of EP. This information may assist in the planning of future educational interventions for emergency physicians. EP seek CPD on management, educational and other non clinical skills, as well as topics relating directly to patient care.

  3. Dynamical aspects on FEL interaction in single passage and storage ring devices

    Energy Technology Data Exchange (ETDEWEB)

    Dattoli, G.; Renieri, A. [ENEA, Frascati (Italy)

    1995-12-31

    The dynamical behaviour of the free-electron lasers is investigated using appropriate scaling relations valid for devices operating in the low and high gain regimes, including saturation. The analysis is applied to both single passage and storage ring configurations. In the latter case the interplay between the interaction of the electron bean with the laser field and with the accelerator environment is investigated. In particular we discuss the effect of FEL interaction on the microwave instability.

  4. Increased drop formation frequency via reduction of surfactant interactions in flow-focusing microfluidic devices.

    Science.gov (United States)

    Josephides, Dimitris N; Sajjadi, Shahriar

    2015-01-27

    Glass capillary based microfluidic devices are able to create extremely uniform droplets, when formed under the dripping regime, at low setup costs due to their ease of manufacture. However, as they are rarely parallelized, simple methods to increase droplet production from a single device are sought. Surfactants used to stabilize drops in such systems often limit the maximum flow rate that highly uniform drops can be produced due to the lowering interfacial tension causing jetting. In this paper we show that by simple design changes we can limit the interactions of surfactants and maximize uniform droplet production. Three flow-focused configurations are explored: a standard glass capillary device (consisting of a single round capillary inserted into a square capillary), a nozzle fed device, and a surfactant shielding device (both consisting of two round capillaries inserted into either end of a square capillary). In principle, the maximum productivity of uniform droplets is achieved if surfactants are not present. It was found that surfactants in the standard device greatly inhibit droplet production by means of interfacial tension lowering and tip-streaming phenomena. In the nozzle fed configuration, surfactant interactions were greatly limited, yielding flow rates comparable to, but lower than, a surfactant-free system. In the surfactant shielding configuration, flow rates were equal to that of a surfactant-free system and could make uniform droplets at rates an order of magnitude above the standard surfactant system.

  5. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  6. Multi-Axis Force Sensor for Human-Robot Interaction Sensing in a Rehabilitation Robotic Device.

    Science.gov (United States)

    Grosu, Victor; Grosu, Svetlana; Vanderborght, Bram; Lefeber, Dirk; Rodriguez-Guerrero, Carlos

    2017-06-05

    Human-robot interaction sensing is a compulsory feature in modern robotic systems where direct contact or close collaboration is desired. Rehabilitation and assistive robotics are fields where interaction forces are required for both safety and increased control performance of the device with a more comfortable experience for the user. In order to provide an efficient interaction feedback between the user and rehabilitation device, high performance sensing units are demanded. This work introduces a novel design of a multi-axis force sensor dedicated for measuring pelvis interaction forces in a rehabilitation exoskeleton device. The sensor is conceived such that it has different sensitivity characteristics for the three axes of interest having also movable parts in order to allow free rotations and limit crosstalk errors. Integrated sensor electronics make it easy to acquire and process data for a real-time distributed system architecture. Two of the developed sensors are integrated and tested in a complex gait rehabilitation device for safe and compliant control.

  7. Analysis of transient electromagnetic wave interactions on graphene-based devices using integral equations

    KAUST Repository

    Shi, Yifei

    2015-10-26

    Graphene is a monolayer of carbon atoms structured in the form of a honeycomb lattice. Recent experimental studies have revealed that it can support surface plasmons at Terahertz frequencies thanks to its dispersive conductivity. Additionally, characteristics of these plasmons can be dynamically adjusted via electrostatic gating of the graphene sheet (K. S. Novoselov, et al., Science, 306, 666–669, 2004). These properties suggest that graphene can be a building block for novel electromagnetic and photonic devices for applications in the fields of photovoltaics, bio-chemical sensing, all-optical computing, and flexible electronics. Simulation of electromagnetic interactions on graphene-based devices is not an easy task. The thickness of the graphene sheet is orders of magnitude smaller than any other geometrical dimension of the device. Consequently, discretization of such a device leads to significantly large number of unknowns and/or ill-conditioned matrix systems.

  8. An evaluation of CPD learning and impact upon positive practice change.

    Science.gov (United States)

    Lee, Nancy-Jane

    2011-05-01

    This paper explores positive practice change in nursing and health care practice following continuing professional development (CPD). It is derived from a commissioned evaluation study within the United Kingdom (UK). Evaluation data was gathered using semi structured discussions with CPD participants, a convenience sample of line managers and University module leaders. Findings suggest that professional peer attitudes and support, when harnessed effectively in the practice setting, strongly enhance positive change. Conversely a lack of engagement with practice peers, a lack of strategic support and not knowing how to access support hinder change. The study found that learning need was often explored through personal development planning and appraisal, however there was little systematic follow up, review and support following learning. Interestingly the individual personal drive and enthusiasm of practitioners was perceived as the strongest factor helping practice change, while policy drivers and national health targets were secondary. Possible strategies to enhance positive practice change are explored. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Barriers to nursing home staff accessing CPD must be broken down.

    Science.gov (United States)

    2016-09-29

    A study on priorities for the professional development of registered nurses (RNs) in nursing homes published in Age and Ageing ( page 6 ) has identified that staff shortages, lack of access to NHS courses and lack of paid study time are the main reasons why RNs do not access continuing professional development (CPD) activities. Specialist gerontological education for care home nurses was, however, seen as a means to ensure that care home nursing attracts the best people.

  10. 77 FR 53903 - Notice of Proposed Information Collection for Public Comment: OneCPD Technical Assistance and...

    Science.gov (United States)

    2012-09-04

    ..., products and group learning activities to benefit CPD grantees and subrecipients. Members of the affected... forms of information technology; e.g., permitting electronic submission of responses. This Notice also...

  11. Self-Consistent Monte Carlo Study of the Coulomb Interaction under Nano-Scale Device Structures

    Science.gov (United States)

    Sano, Nobuyuki

    2011-03-01

    It has been pointed that the Coulomb interaction between the electrons is expected to be of crucial importance to predict reliable device characteristics. In particular, the device performance is greatly degraded due to the plasmon excitation represented by dynamical potential fluctuations in high-doped source and drain regions by the channel electrons. We employ the self-consistent 3D Monte Carlo (MC) simulations, which could reproduce both the correct mobility under various electron concentrations and the collective plasma waves, to study the physical impact of dynamical potential fluctuations on device performance under the Double-gate MOSFETs. The average force experienced by an electron due to the Coulomb interaction inside the device is evaluated by performing the self-consistent MC simulations and the fixed-potential MC simulations without the Coulomb interaction. Also, the band-tailing associated with the local potential fluctuations in high-doped source region is quantitatively evaluated and it is found that the band-tailing becomes strongly dependent of position in real space even inside the uniform source region. This work was partially supported by Grants-in-Aid for Scientific Research B (No. 2160160) from the Ministry of Education, Culture, Sports, Science and Technology in Japan.

  12. Natural Environment Illumination: Coherent Interactive Augmented Reality for Mobile and Non-Mobile Devices.

    Science.gov (United States)

    Rohmer, Kai; Jendersie, Johannes; Grosch, Thorsten

    2017-11-01

    Augmented Reality offers many applications today, especially on mobile devices. Due to the lack of mobile hardware for illumination measurements, photorealistic rendering with consistent appearance of virtual objects is still an area of active research. In this paper, we present a full two-stage pipeline for environment acquisition and augmentation of live camera images using a mobile device with a depth sensor. We show how to directly work on a recorded 3D point cloud of the real environment containing high dynamic range color values. For unknown and automatically changing camera settings, a color compensation method is introduced. Based on this, we show photorealistic augmentations using variants of differential light simulation techniques. The presented methods are tailored for mobile devices and run at interactive frame rates. However, our methods are scalable to trade performance for quality and can produce quality renderings on desktop hardware.

  13. Reclaiming public space: designing for public interaction with private devices

    DEFF Research Database (Denmark)

    Eriksson, Eva; Hansen, Thomas Riisgaard; Lykke-Olesen, Andreas

    2007-01-01

    . In this paper we explore the implications of interacting in public space and how technology can be rethought to not only act as personal devices, but be the tool to reclaim the right and possibility to interact in public spaces. We introduce information exchange, social support and regulation as three central......Public spaces are changing from being ungoverned places for interaction to be more formalized, controlled, less interactive, and designed places aimed at fulfilling a purpose. Simultaneously, new personal mobile technology aims at providing private individual spaces in the public domain...... aspects for reclaiming public space. The PhotoSwapper application is presented as an example of a system designed to integrate pervasive technology in a public setting. The system is strongly inspired by the activities at a traditional market place. Based on the design of the application we discuss four...

  14. Interactive Near-Field Illumination for Photorealistic Augmented Reality with Varying Materials on Mobile Devices.

    Science.gov (United States)

    Rohmer, Kai; Buschel, Wolfgang; Dachselt, Raimund; Grosch, Thorsten

    2015-12-01

    At present, photorealistic augmentation is not yet possible since the computational power of mobile devices is insufficient. Even streaming solutions from stationary PCs cause a latency that affects user interactions considerably. Therefore, we introduce a differential rendering method that allows for a consistent illumination of the inserted virtual objects on mobile devices, avoiding delays. The computation effort is shared between a stationary PC and the mobile devices to make use of the capacities available on both sides. The method is designed such that only a minimum amount of data has to be transferred asynchronously between the participants. This allows for an interactive illumination of virtual objects with a consistent appearance under both temporally and spatially varying real illumination conditions. To describe the complex near-field illumination in an indoor scenario, HDR video cameras are used to capture the illumination from multiple directions. In this way, sources of illumination can be considered that are not directly visible to the mobile device because of occlusions and the limited field of view. While our method focuses on Lambertian materials, we also provide some initial approaches to approximate non-diffuse virtual objects and thereby allow for a wider field of application at nearly the same cost.

  15. An Appeal for heritage interpretation and accessibility. Immersive and interactive virtual reality tours for mobile devices

    OpenAIRE

    Guillermo Duclos Bautista; Javier Cousillas Ripoll

    2013-01-01

    We propose an interactive resource for the value enhancement, management, diffusion and accessibility of the architectural and archaeological heritage by means of virtual reality technologies through mobile devices. The resource is, in addition, a tool for the management of the heritage by the employment of intermediate modules that allow the graphical and alphanumeric update of the external and internal databases put in relation with the resource, depending on the interventions and investiga...

  16. A Synthetic Biology Project - Developing a single-molecule device for screening drug-target interactions.

    Science.gov (United States)

    Firman, Keith; Evans, Luke; Youell, James

    2012-07-16

    This review describes a European-funded project in the area of Synthetic Biology. The project seeks to demonstrate the application of engineering techniques and methodologies to the design and construction of a biosensor for detecting drug-target interactions at the single-molecule level. Production of the proteins required for the system followed the principle of previously described "bioparts" concepts (a system where a database of biological parts - promoters, genes, terminators, linking tags and cleavage sequences - is used to construct novel gene assemblies) and cassette-type assembly of gene expression systems (the concept of linking different "bioparts" to produce functional "cassettes"), but problems were quickly identified with these approaches. DNA substrates for the device were also constructed using a cassette-system. Finally, micro-engineering was used to build a magnetoresistive Magnetic Tweezer device for detection of single molecule DNA modifying enzymes (motors), while the possibility of constructing a Hall Effect version of this device was explored. The device is currently being used to study helicases from Plasmodium as potential targets for anti-malarial drugs, but we also suggest other potential uses for the device. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  17. Proceedings from the second UEMS Conference on CME-CPD in Europe, 28 February 2014, Brussels, Belgium

    Directory of Open Access Journals (Sweden)

    Julie Simper

    2014-09-01

    Full Text Available Over a year since the implementation of the new UEMS-EACCME® accreditation criteria for Live Educational Events (LEEs, the second Union Européenne des Médecins Spécialistes (UEMS Conference on continuing medical education and continuing professional development (CME-CPD in Europe was a much anticipated event. The conference, which took place 28 February 2014 in Brussels, Belgium, provided an important opportunity for stakeholders to discuss and debate:• The role of accreditation in CME-CPD, with a focus on EACCME® accreditation as a means of assuring the quality of CME-CPD in Europe.• The UEMS-EACCME®'s accreditation process.• Implementation of the new criteria for the accreditation of LEEs.A key theme of the event was increased collaboration and dialogue amongst the various stakeholders in international CME-CPD. This was exemplified by both the diversity of the faculty members, as well as the full-house audience of approximately 300 international delegates representing accrediting bodies, medical societies and associations, education providers, industry supporters, and European regulators and legislators. In addition to views on CME-CPD from several of the stakeholder groups, sessions provided a glimpse into the European political environment, CME-CPD statistics, and practical discussions on needs assessment, learning objectives, outcomes measurement, and conflicts of interest management. The day's full agenda also included reiteration of the need for self-regulation of European CME-CPD and commitment to the shared goal of improving patient care by providing high-quality, accredited educational initiatives.

  18. Empowering Older Patients to Engage in Self Care: Designing an Interactive Robotic Device

    Science.gov (United States)

    Tiwari, Priyadarshi; Warren, Jim; Day, Karen

    2011-01-01

    Objectives: To develop and test an interactive robot mounted computing device to support medication management as an example of a complex self-care task in older adults. Method: A Grounded Theory (GT), Participatory Design (PD) approach was used within three Action Research (AR) cycles to understand design requirements and test the design configuration addressing the unique task requirements. Results: At the end of the first cycle a conceptual framework was evolved. The second cycle informed architecture and interface design. By the end of third cycle residents successfully interacted with the dialogue system and were generally satisfied with the robot. The results informed further refinement of the prototype. Conclusion: An interactive, touch screen based, robot-mounted information tool can be developed to support healthcare needs of older people. Qualitative methods such as the hybrid GT-PD-AR approach may be particularly helpful for innovating and articulating design requirements in challenging situations. PMID:22195203

  19. Heart-pulse Biofeedback in Playful Exercise using a Wearable device and Modular Interactive Tiles

    DEFF Research Database (Denmark)

    Shimokakimoto, Tomoya; Lund, Henrik Hautop; Suzuki, Kenji

    2014-01-01

    interactive tiles. The system consists of a wearable device that measures heart-pulse via ear-mounted sensor, and modular interactive tiles which are used for physical rehabilitation exercise through playing a game. The wearable devise enables detection of heart pulse in real-time and therefore provides heart...... beat rate during playful activities, even if the heart pulse wave have motion artifacts. The tiles are designed to build flexible structures and to provide immediate feedback based on the users’ physical interaction with the tiles. We combine the two systems to provide users with heart pulse...... biofeedback in playful exercise. We show that using the developed system it is possible for the users to regulate the exercise intensity on their own with biofeedback, and also possible to analyze exercise activity using number of steps on the tiles and heart beat rate....

  20. Current WTO Negotiations under Doha Round: Insights from CPD's Geneva Tracking Mission

    OpenAIRE

    Mustafizur Rahman; Uttam Kumar Deb; Fahmida Khatun; Khondaker Golam Moazzem

    2008-01-01

    The paper is the output of a Tracking Mission to Geneva by the senior CPD researchers. The paper makes an analysis of the state of play of negotiations at the WTO under the Doha Round as of March 2008. It takes stock of the emerging trends of negotiations in various areas, such as agriculture, NAMA, General Agreement on Trade in Services (GATS), aid for trade, Trade-related Aspects of Intellectual Property Rights (TRIPS), etc., and seeks to project the possible outcomes. An attempt is also ma...

  1. Properties of Pd nanograins in C-Pd composite films obtained by PVD method

    Directory of Open Access Journals (Sweden)

    Kozłowski M.

    2015-09-01

    Full Text Available Properties of palladium nanograins obtained by sedimentation of a soluted C-Pd film prepared by PVD method are presented. These properties were studied using SEM and TEM methods. Dissolved films were prepared by PVD method and after dissolving, they were fractionated to obtain different parts classified with palladium nanograins diameters. Several classes of diameters were determined: below 20 nm, between 20 and 100 nm and above 100 nm. The defects and triple junction were observed. Multishell carbonaceous structures were found in the big and medium size Pd nanograins.

  2. Fostering learners' interaction with content: A learner-centered mobile device interface

    Science.gov (United States)

    Abdous, M.

    2015-12-01

    With the ever-increasing omnipresence of mobile devices in student life, leveraging smart devices to foster students' interaction with course content is critical. Following a learner-centered design iterative approach, we designed a mobile interface that may enable learners to access and interact with online course content efficiently and intuitively. Our design process leveraged recent technologies, such as bootstrap, Google's Material Design, HTML5, and JavaScript to design an intuitive, efficient, and portable mobile interface with a variety of built-in features, including context sensitive bookmarking, searching, progress tracking, captioning, and transcript display. The mobile interface also offers students the ability to ask context-related questions and to complete self-checks as they watch audio/video presentations. Our design process involved ongoing iterative feedback from learners, allowing us to refine and tweak the interface to provide learners with a unified experience across platforms and devices. The innovative combination of technologies built around well-structured and well-designed content seems to provide an effective learning experience to mobile learners. Early feedback indicates a high level of satisfaction with the interface's efficiency, intuitiveness, and robustness from both students and faculty.

  3. Data-driven analysis of interactions between people with dementia and a tablet device

    Directory of Open Access Journals (Sweden)

    Doneit Wolfgang

    2017-09-01

    Full Text Available In the project I-CARE a technical system for tablet devices is developed that captures the personal needs and skills of people with dementia. The system provides activation content such as music videos, biographical photographs and quizzes on various topics of interest to people with dementia, their families and professional caregivers. To adapt the system, the activation content is adjusted to the daily condition of individual users. For this purpose, emotions are automatically detected through facial expressions, motion, and voice. The daily interactions of the users with the tablet devices are documented in log files which can be merged into an event list. In this paper, we propose an advanced format for event lists and a data analysis strategy. A transformation scheme is developed in order to obtain datasets with features and time series for popular methods of data mining. The proposed methods are applied to analysing the interactions of people with dementia with the I-CARE tablet device. We show how the new format of event lists and the innovative transformation scheme can be used to compress the stored data, to identify groups of users, and to model changes of user behaviour. As the I-CARE user studies are still ongoing, simulated benchmark log files are applied to illustrate the data mining strategy. We discuss possible solutions to challenges that appear in the context of I-CARE and that are relevant to a broad range of applications.

  4. UniDA: Uniform Device Access Framework for Human Interaction Environments

    Directory of Open Access Journals (Sweden)

    Santiago Vazquez-Rodriguez

    2011-09-01

    Full Text Available Human interaction environments (HIE must be understood as any place where people carry out their daily life, including their work, family life, leisure and social life, interacting with technology to enhance or facilitate the experience. The integration of technology in these environments has been achieved in a disorderly and incompatible way, with devices operating in isolated islands with artificial edges delimited by the manufacturers. In this paper we are presenting the UniDA framework, an integral solution for the development of systems that require the integration and interoperation of devices and technologies in HIEs. It provides developers and installers with a uniform conceptual framework capable of modelling an HIE, together with a set of libraries, tools and devices to build distributed instrumentation networks with support for transparent integration of other technologies. A series of use case examples and a comparison to many of the existing technologies in the field has been included in order to show the benefits of using UniDA.

  5. A Self-Organizing Interaction and Synchronization Method between a Wearable Device and Mobile Robot.

    Science.gov (United States)

    Kim, Min Su; Lee, Jae Geun; Kang, Soon Ju

    2016-06-08

    In the near future, we can expect to see robots naturally following or going ahead of humans, similar to pet behavior. We call this type of robots "Pet-Bot". To implement this function in a robot, in this paper we introduce a self-organizing interaction and synchronization method between wearable devices and Pet-Bots. First, the Pet-Bot opportunistically identifies its owner without any human intervention, which means that the robot self-identifies the owner's approach on its own. Second, Pet-Bot's activity is synchronized with the owner's behavior. Lastly, the robot frequently encounters uncertain situations (e.g., when the robot goes ahead of the owner but meets a situation where it cannot make a decision, or the owner wants to stop the Pet-Bot synchronization mode to relax). In this case, we have adopted a gesture recognition function that uses a 3-D accelerometer in the wearable device. In order to achieve the interaction and synchronization in real-time, we use two wireless communication protocols: 125 kHz low-frequency (LF) and 2.4 GHz Bluetooth low energy (BLE). We conducted experiments using a prototype Pet-Bot and wearable devices to verify their motion recognition of and synchronization with humans in real-time. The results showed a guaranteed level of accuracy of at least 94%. A trajectory test was also performed to demonstrate the robot's control performance when following or leading a human in real-time.

  6. Engineering of kinase-based protein interacting devices: active expression of tyrosine kinase domains

    KAUST Repository

    Diaz Galicia, Miriam Escarlet

    2018-05-01

    Protein-protein interactions modulate cellular processes in health and disease. However, tracing weak or rare associations or dissociations of proteins is not a trivial task. Kinases are often regulated through interaction partners and, at the same time, themselves regulate cellular interaction networks. The use of kinase domains for creating a synthetic sensor device that reads low concentration protein-protein interactions and amplifies them to a higher concentration interaction which is then translated into a FRET (Fluorescence Resonance Energy Transfer) signal is here proposed. To this end, DNA constructs for interaction amplification (split kinases), positive controls (intact kinase domains), scaffolding proteins and phosphopeptide - SH2-domain modules for the reading of kinase activity were assembled and expression protocols for fusion proteins containing Lyn, Src, and Fak kinase domains in bacterial and in cell-free systems were optimized. Also, two non-overlapping methods for measuring the kinase activity of these proteins were stablished and, finally, a protein-fragment complementation assay with the split-kinase constructs was tested. In conclusion, it has been demonstrated that features such as codon optimization, vector design and expression conditions have an impact on the expression yield and activity of kinase-based proteins. Furthermore, it has been found that the defined PURE cell-free system is insufficient for the active expression of catalytic kinase domains. In contrast, the bacterial co-expression with phosphatases produced active kinase fusion proteins for two out of the three tested Tyrosine kinase domains.

  7. Interacting with and via mobile devices and mobile robots in an assisted living setting

    Directory of Open Access Journals (Sweden)

    Maria Dagioglou

    2015-05-01

    Full Text Available Using robotic home assistants as a platform for remote health monitoring offers several advantages, but also presents considerable challenges related to both the technical immaturity of home robotics and to user acceptance issues. In this paper we explore tablets and similar mobile devices as the medium of communication between robots and their users, presenting relevant current and planned research in humanrobot interaction that can help the telehealth community circumvent technical shortcomings, improve user acceptance, and maximize the quality of the data collected by robotic home assistants.

  8. Rotation gate for a three-level superconducting quantum interference device qubit with resonant interaction

    International Nuclear Information System (INIS)

    Yang, C.-P.; Han Siyuan

    2006-01-01

    We show a way to realize an arbitrary rotation gate in a three-level superconducting quantum interference device (SQUID) qubit using resonant interaction. In this approach, the two logical states of the qubit are represented by the two lowest levels of the SQUID and a higher-energy intermediate level is utilized for the gate manipulation. By considering spontaneous decay from the intermediate level during the gate operation, we present a formula for calculating average fidelity over all possible initial states. Finally, based on realistic system parameters, we show that an arbitrary rotation gate can be achieved with a high fidelity in a SQUID

  9. Meaning-making from CPD - developing practice in own classroom and as a peer in the local science PLC

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund

    . A multiple methods design with repeated observations and interviews was applied. Findings reveal a development over time with the teacher’s reflections in relation to teaching primary science growing to be more confident and personalized, including experiences from inquiry based projects in her own class......Continuous Professional Development (CPD) can be crucial in qualifying teaching, and student learning. Extant research suggests consensus pertaining to the core features of effective continuing professional development including content focus, active learning, coherence, duration, collaborative...... activities and collective participation. This paper present findings from a case-study in the frames of a a large scale, long term CPD program designed according to these criteria. Science teachers from 42 schools/5 municipalities participated from 2012-15 in CPD-activities changing rhythmically between...

  10. An Examination of the Impact of an Assistive Technology Device on the Quality of Adult/Young Child Interactions

    Science.gov (United States)

    Plunkett, Diane M.

    2013-01-01

    The purpose of this study was to gain greater understanding of the potential benefits of assistive technology (AT) devices on young children's social development. Specifically, changes to the quality of the adult/young child social interactions as a function of the child's access to and use of his/her personal AT device was examined. Using a…

  11. Design and Interaction Control of a New Bilateral Upper-Limb Rehabilitation Device

    Directory of Open Access Journals (Sweden)

    Qing Miao

    2017-01-01

    Full Text Available This paper proposed a bilateral upper-limb rehabilitation device (BULReD with two degrees of freedom (DOFs. The BULReD is portable for both hospital and home environment, easy to use for therapists and patients, and safer with respect to upper-limb robotic exoskeletons. It was implemented to be able to conduct both passive and interactive training, based on system kinematics and dynamics, as well as the identification of real-time movement intention of human users. Preliminary results demonstrate the potential of the BULReD for clinical applications, with satisfactory position and interaction force tracking performance. Future work will focus on the clinical evaluation of the BULReD on a large sample of poststroke patients.

  12. Analysis of plasma behavior and electro-magnetic interaction between plasma and device

    International Nuclear Information System (INIS)

    Kobayashi, Tomofumi

    1980-01-01

    A simulation program for the analysis of plasma behavior and the electromagnetic interaction between plasma and device has been developed. The program consists of a part for the analysis of plasma behavior (plasma system) and a part for the analysis of the electro-magnetic interaction between plasma and devices (circuit system). The parameters which connect the plasma system and the circuit system are the electric resistance of plasma, the internal inductance, and the plasma current. For the plasma system, the simultaneous equations which describe the density distribution of plasma particles, the temperature distribution of electrons and ions, and the space-time variation of current density distribution were derived. The one-dimensional plasma column in γ-direction was considered. The electric resistance and the internal inductance can be deduced. The circuit components are a current transformer, a vertical field coil, a quadrupole field coil, a vacuum chamber and others. An equation which describes plasma position and the shape of cross section is introduced. The plasma position can be known by solving the Mukhavatov's formula of equilibrium. By using this program, the build-up process of plasma current in JT-60 was analysed. It was found that the expansion of plasma sub radius and the control of current distribution by gas injection are the effective methods to obtain high temperature and high density plasma. The eddy current induced in a vacuum vessel shields 40 percent of magnetic field made in the plasma region by a vertical field coil. (Kato, T.)

  13. Interacting with the biomolecular solvent accessible surface via a haptic feedback device

    Directory of Open Access Journals (Sweden)

    Hayward Steven

    2009-10-01

    Full Text Available Abstract Background From the 1950s computer based renderings of molecules have been produced to aid researchers in their understanding of biomolecular structure and function. A major consideration for any molecular graphics software is the ability to visualise the three dimensional structure of the molecule. Traditionally, this was accomplished via stereoscopic pairs of images and later realised with three dimensional display technologies. Using a haptic feedback device in combination with molecular graphics has the potential to enhance three dimensional visualisation. Although haptic feedback devices have been used to feel the interaction forces during molecular docking they have not been used explicitly as an aid to visualisation. Results A haptic rendering application for biomolecular visualisation has been developed that allows the user to gain three-dimensional awareness of the shape of a biomolecule. By using a water molecule as the probe, modelled as an oxygen atom having hard-sphere interactions with the biomolecule, the process of exploration has the further benefit of being able to determine regions on the molecular surface that are accessible to the solvent. This gives insight into how awkward it is for a water molecule to gain access to or escape from channels and cavities, indicating possible entropic bottlenecks. In the case of liver alcohol dehydrogenase bound to the inhibitor SAD, it was found that there is a channel just wide enough for a single water molecule to pass through. Placing the probe coincident with crystallographic water molecules suggests that they are sometimes located within small pockets that provide a sterically stable environment irrespective of hydrogen bonding considerations. Conclusion By using the software, named HaptiMol ISAS (available from http://www.haptimol.co.uk, one can explore the accessible surface of biomolecules using a three-dimensional input device to gain insights into the shape and water

  14. Defining interactions of in-stream hydrokinetic devices in the Tanana River, Alaska

    Science.gov (United States)

    Johnson, J.; Toniolo, H.; Seitz, A. C.; Schmid, J.; Duvoy, P.

    2012-12-01

    The acceptance, performance, and sustainability of operating in-stream hydrokinetic power generating devices in rivers depends on the impact of the river environment on hydrokinetic infrastructure as well as its impact on the river environment. The Alaska Hydrokinetic Energy Research Center (AHERC) conducts hydrokinetic "impact" and technology studies needed to support a sustainable hydrokinetic industry in Alaska. These include completed and ongoing baseline studies of river hydrodynamic conditions (river stage, discharge, current velocity, power, and turbulence; suspended and bed load sediment transport), ice, fish populations and behavior, surface and subsurface debris flows, and riverbed conditions. Technology and methods studies to minimize the effect of debris flows on deployed turbine system are in-progress to determine their effectiveness at reducing the probability of debris impact, diverting debris and their affect on available river power for conversion to electricity. An anchor point has been placed in the main flow just upstream of Main (Figure 1) to support projects and in preparation for future projects that are being planned to examine hydrokinetic turbine performance including power conversion efficiency, turbine drag and anchor chain loads, wake generation and effects on fish. Baseline fish studies indicate that hydrokinetic devices at the test site will have the most potential interactions with Pacific salmon smolts during their down-migration to the ocean in May and June. At the AHERC test site, the maximum turbulent kinetic energy (TKE) occurs just down stream from the major river bends (e.g., 000 and near the railroad bridge [upper center of the figure]) and over a deep hole at 440 (Figure 1), Minimum TKE occurs between main and 800. River current velocity measurements and simulations of river flow from 000 downstream past the railroad bridge indicate that the most stable current in the river reach is between Main and 800. The stable current

  15. Observational constraints for the circumstellar disk of the B[e] star CPD-52 9243

    Science.gov (United States)

    Cidale, L. S.; Borges Fernandes, M.; Andruchow, I.; Arias, M. L.; Kraus, M.; Chesneau, O.; Kanaan, S.; Curé, M.; de Wit, W. J.; Muratore, M. F.

    2012-12-01

    Context. The formation and evolution of gas and dust environments around B[e] supergiants are still open issues. Aims: We intend to study the geometry, kinematics and physical structure of the circumstellar environment (CE) of the B[e] supergiant CPD-52 9243 to provide further insights into the underlying mechanism causing the B[e] phenomenon. Methods: The influence of the different physical mechanisms acting on the CE (radiation pressure, rotation, bi-stability or tidal forces) is somehow reflected in the shape and kinematic properties of the gas and dust regions (flaring, Keplerian, accretion or outflowing disks). To investigate these processes we mainly used quasi-simultaneous observations taken with high spatial resolution optical long-baseline interferometry (VLTI/MIDI), near-IR spectroscopy of CO bandhead features (Gemini/Phoenix and VLT/CRIRES) and optical spectra (CASLEO/REOSC). Results: High angular resolution interferometric measurements obtained with VLTI/MIDI provide strong support for the presence of a dusty disk(ring)-like structure around CPD-52 9243, with an upper limit for its inner edge of ~8 mas (~27.5 AU, considering a distance of 3.44 kpc to the star). The disk has an inclination angle with respect to the line of sight of 46 ± 7°. The study of CO first overtone bandhead evidences a disk structure in Keplerian rotation. The optical spectrum indicates a rapid outflow in the polar direction. Conclusions: The IR emission (CO and warm dust) indicates Keplerian rotation in a circumstellar disk while the optical line transitions of various species are consistent with a polar wind. Both structures appear simultaneously and provide further evidence for the proposed paradigms of the mass-loss in supergiant B[e] stars. The presence of a detached cold CO ring around CPD-52 9243 could be due to a truncation of the inner disk caused by a companion, located possibly interior to the disk rim, clearing the center of the system. More spectroscopic and

  16. Benefits of Continuing Professional Development (CPD) Programmes in Music for KS2 (Primary) Teachers through the Example of the London Symphony Orchestra (LSO) on Track Programme

    Science.gov (United States)

    Varvarigou, Maria; Creech, Andrea; Hallam, Susan

    2012-01-01

    Between September 2008 and August 2010 24 KS2 classroom teachers were involved in a two-year programme of continuing professional development (CPD), delivered by the LSO in partnership with Local Authority Music Services. The teachers indicated that they embarked on the CPD programme looking forward to opportunities to share good practice, gain…

  17. Quantum interference measurement of spin interactions in a bio-organic/semiconductor device structure

    Science.gov (United States)

    Deo, Vincent; Zhang, Yao; Soghomonian, Victoria; Heremans, Jean J.

    2015-03-01

    Quantum interference is used to measure the spin interactions between an InAs surface electron system and the iron center in the biomolecule hemin in nanometer proximity in a bio-organic/semiconductor device structure. The interference quantifies the influence of hemin on the spin decoherence properties of the surface electrons. The decoherence times of the electrons serve to characterize the biomolecule, in an electronic complement to the use of spin decoherence times in magnetic resonance. Hemin, prototypical for the heme group in hemoglobin, is used to demonstrate the method, as a representative biomolecule where the spin state of a metal ion affects biological functions. The electronic determination of spin decoherence properties relies on the quantum correction of antilocalization, a result of quantum interference in the electron system. Spin-flip scattering is found to increase with temperature due to hemin, signifying a spin exchange between the iron center and the electrons, thus implying interactions between a biomolecule and a solid-state system in the hemin/InAs hybrid structure. The results also indicate the feasibility of artificial bioinspired materials using tunable carrier systems to mediate interactions between biological entities.

  18. Use of speech generating devices can improve perception of qualifications for skilled, verbal, and interactive jobs.

    Science.gov (United States)

    Stern, Steven E; Chobany, Chelsea M; Beam, Alexander A; Hoover, Brittany N; Hull, Thomas T; Linsenbigler, Melissa; Makdad-Light, Courtney; Rubright, Courtney N

    2017-01-01

    We have previously demonstrated that when speech generating devices (SGD) are used as assistive technologies, they are preferred over the users' natural voices. We sought to examine whether using SGDs would affect listener's perceptions of hirability of people with complex communication needs. In a series of three experiments, participants rated videotaped actors, one using SGD and the other using their natural, mildly dysarthric voice, on (a) a measurement of perceptions of speaker credibility, strength, and informedness and (b) measurements of hirability for jobs coded in terms of skill, verbal ability, and interactivity. Experiment 1 examined hirability for jobs varying in terms of skill and verbal ability. Experiment 2 was a replication that examined hirability for jobs varying in terms of interactivity. Experiment 3 examined jobs in terms of skill and specific mode of interaction (face-to-face, telephone, computer-mediated). Actors were rated more favorably when using SGD than their own voices. Actors using SGD were also rated more favorably for highly skilled and highly verbal jobs. This preference for SGDs over mildly dysarthric voice was also found for jobs entailing computer-mediated-communication, particularly skillful jobs.

  19. A 3D character animation engine for multimodal interaction on mobile devices

    Science.gov (United States)

    Sandali, Enrico; Lavagetto, Fabio; Pisano, Paolo

    2005-03-01

    Talking virtual characters are graphical simulations of real or imaginary persons that enable natural and pleasant multimodal interaction with the user, by means of voice, eye gaze, facial expression and gestures. This paper presents an implementation of a 3D virtual character animation and rendering engine, compliant with the MPEG-4 standard, running on Symbian-based SmartPhones. Real-time animation of virtual characters on mobile devices represents a challenging task, since many limitations must be taken into account with respect to processing power, graphics capabilities, disk space and execution memory size. The proposed optimization techniques allow to overcome these issues, guaranteeing a smooth and synchronous animation of facial expressions and lip movements on mobile phones such as Sony-Ericsson's P800 and Nokia's 6600. The animation engine is specifically targeted to the development of new "Over The Air" services, based on embodied conversational agents, with applications in entertainment (interactive story tellers), navigation aid (virtual guides to web sites and mobile services), news casting (virtual newscasters) and education (interactive virtual teachers).

  20. A microdot multilayer oxide device: let us tune the strain-ionic transport interaction.

    Science.gov (United States)

    Schweiger, Sebastian; Kubicek, Markus; Messerschmitt, Felix; Murer, Christoph; Rupp, Jennifer L M

    2014-05-27

    In this paper, we present a strategy to use interfacial strain in multilayer heterostructures to tune their resistive response and ionic transport as active component in an oxide-based multilayer microdot device on chip. For this, fabrication of strained multilayer microdot devices with sideways attached electrodes is reported with the material system Gd0.1Ce0.9O(2-δ)/Er2O3. The fast ionic conducting Gd0.1Ce0.9O(2-δ) single layers are altered in lattice strain by the electrically insulating erbia phases of a microdot. The strain activated volume of the Gd0.1Ce0.9O(2-δ) is investigated by changing the number of individual layers from 1 to 60 while keeping the microdot at a constant thickness; i.e., the proportion of strained volume was systematically varied. Electrical measurements showed that the activation energy of the devices could be altered by Δ0.31 eV by changing the compressive strain of a microdot ceria-based phase by more than 1.16%. The electrical conductivity data is analyzed and interpreted with a strain volume model and defect thermodynamics. Additionally, an equivalent circuit model is presented for sideways contacted multilayer microdots. We give a proof-of-concept for microdot contacting to capture real strain-ionic transport effects and reveal that for classic top-electrode contacting the effect is nil, highlighting the need for sideways electric contacting on a nanoscopic scale. The near order ionic transport interaction is supported by Raman spectroscopy measurements. These were conducted and analyzed together with fully relaxed single thin film samples. Strain states are described relative to the strain activated volumes of Gd0.1Ce0.9O(2-δ) in the microdot multilayer. These findings reveal that strain engineering in microfabricated devices allows altering the ionic conduction over a wide range beyond classic doping strategies for single films. The reported fabrication route and concept of strained multilayer microdots is a promising path

  1. 77 FR 69497 - Notice of Submission of Proposed Information Collection to OMB; Funding Availability for OneCPD...

    Science.gov (United States)

    2012-11-19

    ... Proposed Information Collection to OMB; Funding Availability for OneCPD Technical Assistance and Capacity..., prevent and reduce homelessness, improve data collection and reporting, and use coordinated neighborhood... increase the supply of affordable housing units, prevent and reduce homelessness, improve data collection...

  2. 77 FR 69496 - Notice of Submission of Proposed Information Collection to OMB; OneCPD Technical Assistance and...

    Science.gov (United States)

    2012-11-19

    ... and assist in prioritizing the development of tools, products and group learning activities to benefit... prioritizing the development of tools, products and group learning activities to benefit CPD grantees and... through the use of appropriate automated collection techniques or other forms of information technology, e...

  3. Plasma edge and plasma-wall interaction modelling: Lessons learned from metallic devices

    Directory of Open Access Journals (Sweden)

    S. Wiesen

    2017-08-01

    Full Text Available Robust power exhaust schemes employing impurity seeding are needed for target operational scenarios in present day tokamak devices with metallic plasma-facing components (PFCs. For an electricity-producing fusion power plant at power density Psep/R>15MW/m divertor detachment is a requirement for heat load mitigation. 2D plasma edge transport codes like the SOLPS code as well as plasma-wall interaction (PWI codes are key to disentangle relevant physical processes in power and particle exhaust. With increased quantitative credibility in such codes more realistic and physically sound estimates of the life-time expectations and performance of metallic PFCs can be accomplished for divertor conditions relevant for ITER and DEMO. An overview is given on the recent progress of plasma edge and PWI modelling activities for (carbon-free metallic devices, that include results from JET with the ITER-like wall, ASDEX Upgrade and Alcator C-mod. It is observed that metallic devices offer an opportunity to progress the understanding of underlying plasma physics processes in the edge. The validation of models can be substantially improved by eliminating carbon from the experiment as well as from the numerical system with reduced degrees of freedom as no chemical sputtering from amorphous carbon layers and no carbon or hydro-carbon transport are present. With the absence of carbon as the primary plasma impurity and given the fact that the physics of the PWI at metallic walls is less complex it is possible to isolate the crucial plasma physics processes relevant for particle and power exhaust. For a reliable 2D dissipative plasma exhaust model these are: cross-field drifts, complete kinetic neutral physics, geometry effects (including main-chamber, divertor and sub-divertor structures, SOL transport reflecting also the non-diffusive nature of anomalous transport, as well as transport within the pedestal region in case of significant edge impurity radiation

  4. Nonlinear fluid/structure interaction relating a rupture-disc pressure-relief device

    International Nuclear Information System (INIS)

    Hsieh, B.J.; Kot, C.A.; Shin, Y.W.; Youngdahl, C.K.

    1983-01-01

    Rupture disc assemblies are used in piping network systems as a pressure-relief device. The reverse-buckling type is chosen for application in a liquid metal fast breeder reactor. This assembly is used successfully in systems in which the fluid is highly compressible, such as air; the opening up of the disc by the knife setup is complete. However, this is not true for a liquid system; it had been observed experimentally that the disc may open up only partially or not at all. Therefore, to realistically understand and represent a rupture disc assembly in a liquid environment, the fluid-structure interactions between the liquid medium and the disc assembly must be considered. The methods for analyzing the fluid and the disc and the mechanism interconnecting them are presented. The fluid is allowed to cavitate through a column-cavitation model and the disc is allowed to become plastically deformed through the classic Von Mises' yield criteria, when necessary

  5. An Appeal for heritage interpretation and accessibility. Immersive and interactive virtual reality tours for mobile devices

    Directory of Open Access Journals (Sweden)

    Guillermo Duclos Bautista

    2013-11-01

    Full Text Available We propose an interactive resource for the value enhancement, management, diffusion and accessibility of the architectural and archaeological heritage by means of virtual reality technologies through mobile devices. The resource is, in addition, a tool for the management of the heritage by the employment of intermediate modules that allow the graphical and alphanumeric update of the external and internal databases put in relation with the resource, depending on the interventions and investigations that on the monument are taking place in the time. Furthermore, the resource is a powerful compensatory measure for the virtual accessibility to the heritage by persons with limited mobility and / or sensory deficiencies.

  6. Usability Testing of a Collaborative and Interactive University on a Mobile Device

    Directory of Open Access Journals (Sweden)

    Gavin McArdle

    2009-10-01

    Full Text Available Abstract - The use of mobile devices for delivering learning tools is an attractive concept. Termed mobile learning (m-learning, this new technology allows people to participate in learning activities without being tied to a fixed location and provides users with convenient and flexible access to learning resources anytime and anywhere. While many m-learning applications have been developed to date, most provide tools to help students’ with specific learning tasks rather than a general interface to online courses. Few sup-port online learning communities or allow users to download multimedia learning content. These features would engage mobile users and enable them to interact with one another, thus allowing them to participate in group learning activities despite their changing location. In this article, we describe an m-learning system which we have developed which aims to incorporate these facilities. This system provides access to multimedia learning resources and supports mobile users in an interactive synchronous learning environment with their desktop peers. Details of the evaluation techniques which we utilised to appraise the system are provided and the results are presented. Feedback suggests that the features offered by our system are beneficial for collaborative m-learning.

  7. Exploring the requirements for multimodal interaction for mobile devices in an end-to-end journey context.

    Science.gov (United States)

    Krehl, Claudia; Sharples, Sarah

    2012-01-01

    The paper investigates the requirements for multimodal interaction on mobile devices in an end-to-end journey context. Traditional interfaces are deemed cumbersome and inefficient for exchanging information with the user. Multimodal interaction provides a different user-centred approach allowing for more natural and intuitive interaction between humans and computers. It is especially suitable for mobile interaction as it can overcome additional constraints including small screens, awkward keypads, and continuously changing settings - an inherent property of mobility. This paper is based on end-to-end journeys where users encounter several contexts during their journeys. Interviews and focus groups explore the requirements for multimodal interaction design for mobile devices by examining journey stages and identifying the users' information needs and sources. Findings suggest that multimodal communication is crucial when users multitask. Choosing suitable modalities depend on user context, characteristics and tasks.

  8. The weak π − π interaction originated resonant tunneling and fast switching in the carbon based electronic devices

    Directory of Open Access Journals (Sweden)

    Jun He

    2012-03-01

    Full Text Available By means of the nonequilibrium Green's functions and the density functional theory, we have investigated the electronic transport properties of C60 based electronic device with different intermolecular interactions. It is found that the electronic transport properties vary with the types of the interaction between two C60 molecules. A fast electrical switching behavior based on negative differential resistance has been found when two molecules are coupled by the weak π − π interaction. Compared to the solid bonding, the weak interaction is found to induce resonant tunneling, which is responsible for the fast response to the applied electric field and hence the velocity of switching.

  9. Preliminary outcomes of the IUCR CPD round robin on quantitative phase analysis

    International Nuclear Information System (INIS)

    Madsen, I.

    1999-01-01

    Full text: The International Union for Crystallography - Commission on Powder Diffraction is currently sponsoring a round robin on quantitative phase analysis (QPA). The round robin is focusing on the analysis of powder diffraction data, namely laboratory X-ray, synchrotron X-ray and neutron diffraction data for the derivation of phase abundances. The general goals of the round robin include the following: 1. To document the methods and strategies commonly employed in quantitative phase analysis, especially those involving powder diffraction. 2. To assess (i) levels of accuracy and precision, and (ii) lower limits of detection of methods used in QPA. 3. To identify specific problem areas and develop practical solutions. 4. To formulate recommended procedures for QPA using diffraction data. 5. To create a standard set of samples for future reference. The samples used in the study consist of mixtures of major and minor components covering a wide range of analytical complexity. Initial samples are synthetic mixtures of crystallographically 'simple' materials and should present little problem to the analyst. Additional samples introduce problems such as preferred orientation, microabsorption and amorphous content to assess the degree to which these problems affect QPA. Several very complex materials have also been included in the sample suite including a natural granodiorite, synthetic bauxite and a mixture of pharmaceutical phases. These last three samples represent a significant analytical challenge as they exhibit preferred orientation, microabsorption and grain size effects in addition to severe peak overlap. The round robin was tailored to allow variation in the level of participation including (i) analysis of 'standard' data sets supplied by the CPD, (ii) collection and analysis of data from at least two of the samples supplied by the CPD and (iii) selection of additional samples at the discretion of the participant. At the time of writing this abstract, some 130

  10. Posttransfusional changes of 2,3-diphosphoglycerate and nucleotides in CPD-SAGM-preserved erythrocytes.

    Science.gov (United States)

    Matthes, G; Strunk, S; Siems, W; Grune, T

    1993-06-01

    Posttransfusional changes of preserved red blood cells can influence the oxygen equilibrium curve which is mainly affected by the concentration of erythrocyte 2,3-diphosphoglycerate (DPG). The regeneration kinetics of DPG and nucleotides (ATP, ADP, AMP, GTP, GDP) was determined over a period of 0-48 h in surgically treated patients following transfusion of DPG-depleted packed red cells stored for 14 days in CPD-SAGM. 3 h after transfusion the DPG levels raised up to 40% of the patients' prior DPG concentrations. Complete regeneration of the DPG concentrations occurred 36-48 h after transfusion. Changes in the nucleotide pattern indicate, after a temporary decrease of ATP and GTP levels (after 10-30 min) and an activation phase (after 3-12 h), the full regeneration of these parameters 24-48 h after transfusion. The regeneration kinetics of DPG should be taken into consideration for transfusions with blood units stored for more than 14 days, especially in patients with reduced compensatory mechanisms (coronary and cerebral scleroses, pacemaker, etc.) and large transfusion volumes.

  11. The recertification of the professional accounting qualification in Estonia: the requirements and quality of CPD

    Directory of Open Access Journals (Sweden)

    Kaidi Kallaste

    2017-09-01

    Full Text Available The recertification of the professional accounting qualification in Estonia: the requirements and quality of CPD As the purpose of a professional qualification should be to ensure quality to employers/customers, appro-priate requirements for professional training should not be too low. On the other hand, too high require-ments for the amount of training would lead to the situation where maintaining the level is expensive and if the labour market does not consider having a professional certificate necessary, recertification will be discarded. The purpose of the research was to identify the factors that influence an accountant’s decision whether to recertify his/her professional qualification or not. The conditions of recertification were ana-lysed and compared to other countries as were the requirements set up for auditors. The results of the survey revealed that in Estonia the decision not to recertify one’s professional qualification was mainly due to not having fulfilled the required number of qualification hours or not having certificates proving one’s participation in qualification training sessions. At the same time, compared to other countries, the requirements in Estonia are very low. So that the increase in the amount of training would not hinder recertification, alternative solutions for Estonia are proposed in the article.

  12. Effects of irradiation on red cells stored in CPDA-1 and CPD-ADSOL (AS-1)

    International Nuclear Information System (INIS)

    Jeter, E.K.; Gadsden, R.H.; Cate, J.

    1991-01-01

    Red blood cells (pRBC) collected in citrate, phosphate, dextrose, adenine-formula 1 (CPDA-1) and citrate, phosphate, dextrose-adenine, manitol saline solution (CPD-ADSOL [AS-1]) anticoagulants are increasingly being stored for variable periods in transfusion service inventories following irradiation. While anecdotal reports of increased K+ following irradiation and storage have recently appeared in the literature, concomitant in vitro biochemical changes resulting from differences in anticoagulants have not been reported. Utilizing two venipunctures, two units each of 225 mL of blood from five volunteers were collected in anticoagulant-adjusted CPDA-1 and AS-1 bags. Within two hours of collection, each unit was equally divided. One of each pair was irradiated (2000 rads). Samples were analyzed on Days 0, 1, 3, 7, and every seven days to expiration. Irradiation resulted in a 2.3 fold increase in K+ during the first seven days of storage for both anticoagulants, although significantly greater K+ levels were observed in the CPDA-1 pairs compared to the AS-1 pairs. Comparison of glucose utilization, plasma free hemoglobin, 2,3-diphosphoglycerate (2,3-DPG) and lactate dehydrogenase between control and irradiated CPDA-1 and AS-1 pairs and between anticoagulants were documented

  13. Facilitating Integration of Electron Beam Lithography Devices with Interactive Videodisc, Computer-Based Simulation and Job Aids.

    Science.gov (United States)

    Von Der Linn, Robert Christopher

    A needs assessment of the Grumman E-Beam Systems Group identified the requirement for additional skill mastery for the engineers who assemble, integrate, and maintain devices used to manufacture integrated circuits. Further analysis of the tasks involved led to the decision to develop interactive videodisc, computer-based job aids to enable…

  14. Interaction Problems Accessing E-Learning Environments in Multi-Touch Mobile Devices: A Case Study in TelEduc

    Science.gov (United States)

    da Silva, André Constantino; Freire, Fernanda Maria Pereira; de Arruda, Alan Victor Pereira; da Rocha, Heloísa Vieira

    2013-01-01

    e-Learning environments offer content, such text, audio, video, animations, using the Web infrastructure and they are designed to users interacting with keyboard, mouse and a medium-sized screen. Mobile devices, such as smartphones and tablets, have enough computation power to render Web pages, allowing browsing the Internet and access e-Learning…

  15. Meaning-making from CPD – developing practice in own classroom and as a peer in the local science PLC

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund

    2017-01-01

    reveal a development where the teacher’s reflections in relation to teaching primary science grew to be more confident and personalized, including experiences from her own class, and more detailed regarding supporting student learning. Furthermore, over time, a closer connection between the teacher...... by the school-leader e.g. to develop the local science team to also involve primary science teachers. The case-study exemplifies the complex interplay between individual and collaborative agency among teachers, and contextual factors like leadership, in starting and sustaining a positive spiral.......Continuous Professional Development (CPD) can be crucial in qualifying teaching, and student learning. Extant research suggests consensus pertaining to the core features of effective CPD including content focus, active learning, coherence, duration, collaborative activities and collective...

  16. What do you really need to know? The importance of the third space in developing institutional CPD frameworks

    OpenAIRE

    Marr, Elizabeth; Forsyth, Rachel

    2011-01-01

    This paper argues for a collaborative approach between administrative and academic staff in the development and delivery of institutional CPD programmes in order to reduce the risk of diminution of quality and standards in higher education and to ensure equality of opportunity in career development.\\ud \\ud The rate of change in UK higher education has accelerated considerably in the last decade. Within this context, the ‘doing’ of higher education work has become much more diverse, encompassi...

  17. Rotation, spectral variability, magnetic geometry and magnetosphere of the Of?p star CPD -28° 2561

    OpenAIRE

    Wade, G. A.; Barba, R. H.; Grunhut, J.; Martins, F.; Petit, V.; Sundqvist, J. O.; Townsend, R. H. D.; Walborn, N. R.; Alecian, E.; Alfaro, E. J.; Maíz Apellaniz, J; Arias, Julia Ines; Gamen, Roberto Claudio; Morrell, Nidia Irene; Naze, Y.

    2017-01-01

    We report magnetic and spectroscopic observations and modelling of the Of?p star CPD −28° 2561. Using more than 75 new spectra, we have measured the equivalent width variations and examined the dynamic spectra of photospheric and wind-sensitive spectral lines. A period search results in an unambiguous 73.41 d variability period. High-resolution spectropolarimetric data analysed using least-squares deconvolution yield a Zeeman signature detected in the mean Stokes V profile corresponding to ph...

  18. Assessing the potential roles of silicon and germanium phthalocyanines in planar heterojunction organic photovoltaic devices and how pentafluoro phenoxylation can enhance π-π interactions and device performance.

    Science.gov (United States)

    Lessard, Benoît H; White, Robin T; Al-Amar, Mohammad; Plint, Trevor; Castrucci, Jeffrey S; Josey, David S; Lu, Zheng-Hong; Bender, Timothy P

    2015-03-11

    In this study, we have assessed the potential application of dichloro silicon phthalocyanine (Cl2-SiPc) and dichloro germanium phthalocyanine (Cl2-GePc) in modern planar heterojunction organic photovoltaic (PHJ OPV) devices. We have determined that Cl2-SiPc can act as an electron donating material when paired with C60 and that Cl2-SiPc or Cl2-GePc can also act as an electron acceptor material when paired with pentacene. These two materials enabled the harvesting of triplet energy resulting from the singlet fission process in pentacene. However, contributions to the generation of photocurrent were observed for Cl2-SiPc with no evidence of photocurrent contribution from Cl2-GePc. The result of our initial assessment established the potential for the application of SiPc and GePc in PHJ OPV devices. Thereafter, bis(pentafluoro phenoxy) silicon phthalocyanine (F10-SiPc) and bis(pentafluoro phenoxy) germanium phthalocyanine (F10-GePc) were synthesized and characterized. During thermal processing, it was discovered that F10-SiPc and F10-GePc underwent a reaction forming small amounts of difluoro SiPc (F2-SiPc) and difluoro GePc (F2-GePc). This undesirable reaction could be circumvented for F10-SiPc but not for F10-GePc. Using single crystal X-ray diffraction, it was determined that F10-SiPc has significantly enhanced π-π interactions compared with that of Cl2-SiPc, which had little to none. Unoptimized PHJ OPV devices based on F10-SiPc were fabricated and directly compared to those constructed from Cl2-SiPc, and in all cases, PHJ OPV devices based on F10-SiPc had significantly improved device characteristics compared to Cl2-SiPc.

  19. Differential biologic effects of CPD and 6-4PP UV-induced DNA damage on the induction of apoptosis and cell-cycle arrest

    International Nuclear Information System (INIS)

    Lo, Hsin-Lung; Nakajima, Satoshi; Ma, Lisa; Walter, Barbara; Yasui, Akira; Ethell, Douglas W; Owen, Laurie B

    2005-01-01

    UV-induced damage can induce apoptosis or trigger DNA repair mechanisms. Minor DNA damage is thought to halt the cell cycle to allow effective repair, while more severe damage can induce an apoptotic program. Of the two major types of UV-induced DNA lesions, it has been reported that repair of CPD, but not 6-4PP, abrogates mutation. To address whether the two major forms of UV-induced DNA damage, can induce differential biological effects, NER-deficient cells containing either CPD photolyase or 6-4 PP photolyase were exposed to UV and examined for alterations in cell cycle and apoptosis. In addition, pTpT, a molecular mimic of CPD was tested in vitro and in vivo for the ability to induce cell death and cell cycle alterations. NER-deficient XPA cells were stably transfected with CPD-photolyase or 6-4PP photolyase to specifically repair only CPD or only 6-4PP. After 300 J/m 2 UVB exposure photoreactivation light (PR, UVA 60 kJ/m 2 ) was provided for photolyase activation and DNA repair. Apoptosis was monitored 24 hours later by flow cytometric analysis of DNA content, using sub-G1 staining to indicate apoptotic cells. To confirm the effects observed with CPD lesions, the molecular mimic of CPD, pTpT, was also tested in vitro and in vivo for its effect on cell cycle and apoptosis. The specific repair of 6-4PP lesions after UVB exposure resulted in a dramatic reduction in apoptosis. These findings suggested that 6-4PP lesions may be the primary inducer of UVB-induced apoptosis. Repair of CPD lesions (despite their relative abundance in the UV-damaged cell) had little effect on the induction of apoptosis. Supporting these findings, the molecular mimic of CPD, (dinucleotide pTpT) could mimic the effects of UVB on cell cycle arrest, but were ineffective to induce apoptosis. The primary response of the cell to UV-induced 6-4PP lesions is to trigger an apoptotic program whereas the response of the cell to CPD lesions appears to principally involve cell cycle arrest. These

  20. Quantifying Age-Related Differences in Human Reaching while Interacting with a Rehabilitation Robotic Device

    Directory of Open Access Journals (Sweden)

    Vivek Yadav

    2010-01-01

    Full Text Available New movement assessment and data analysis methods are developed to quantify human arm motion patterns during physical interaction with robotic devices for rehabilitation. These methods provide metrics for future use in diagnosis, assessment and rehabilitation of subjects with affected arm movements. Specifically, the current study uses existing pattern recognition methods to evaluate the effect of age on performance of a specific motion, reaching to a target by moving the end-effector of a robot (an X-Y table. Differences in the arm motion patterns of younger and older subjects are evaluated using two measures: the principal component analysis similarity factor (SPCA to compare path shape and the number of Fourier modes representing 98% of the path ‘energy’ to compare the smoothness of movement, a particularly important variable for assessment of pathologic movement. Both measures are less sensitive to noise than others previously reported in the literature and preserve information that is often lost through other analysis techniques. Data from the SPCA analysis indicate that age is a significant factor affecting the shapes of target reaching paths, followed by reaching movement type (crossing body midline/not crossing and reaching side (left/right; hand dominance and trial repetition are not significant factors. Data from the Fourier-based analysis likewise indicate that age is a significant factor affecting smoothness of movement, and movements become smoother with increasing trial number in both younger and older subjects, although more rapidly so in younger subjects. These results using the proposed data analysis methods confirm current practice that age-matched subjects should be used for comparison to quantify recovery of arm movement during rehabilitation. The results also highlight the advantages that these methods offer relative to other reported measures.

  1. Ways of Telecommunications Interaction Arrangement for Microprocessor Devices of Different Types in Composition of Multi-Motor Electric Drives

    Science.gov (United States)

    Shpenst, V. A.; Vasiliev, B. Y.; Kalashnikov, O. V.; Oleynikova, A. M.

    2018-05-01

    The article covers a consideration of various state-of-the-art industrial data transfer protocols, e.g. Modbus, Profibus, Industrial Ethernet and CAN. Their pros and cons are analyzed and conclusions made on advisability of the use of each protocol. It is shown that for the arrangement of effective telecommunication interaction of microprocessor devices of different types in the composition of multi-motor electric drives, it is advisable to use highlevel CAN-protocols, such as CANopen and DeviceNet.

  2. The Effect of Interacting with Two Devices when Creating the Illusion of Internal State in Tangible Widgets

    DEFF Research Database (Denmark)

    Bech, Christoffer; Bork, Andreas Heldbjerg; Memborg, Jakob Birch

    2017-01-01

    This paper investigates whether the illusion of internal state in passive tangible widgets is stronger when using one touchscreen device or two devices. Passive tangible widgets are an increasingly popular way to interact with tablet games. Since the production of passive widgets is usually cheaper...... than the production of widgets with internal state, it is much more cost-efficient to induce the illusion of internal state in passive widgets than to use tangible widgets with an actual internal state. An experiment was conducted where the participants’ belief in the illusion was determined by means...

  3. Particle interaction and displacement damage in silicon devices operated in radiation environments

    International Nuclear Information System (INIS)

    Leroy, Claude; Rancoita, Pier-Giorgio

    2007-01-01

    Silicon is used in radiation detectors and electronic devices. Nowadays, these devices achieving submicron technology are parts of integrated circuits of large to very large scale integration (VLSI). Silicon and silicon-based devices are commonly operated in many fields including particle physics experiments, nuclear medicine and space. Some of these fields present adverse radiation environments that may affect the operation of the devices. The particle energy deposition mechanisms by ionization and non-ionization processes are reviewed as well as the radiation-induced damage and its effect on device parameters evolution, depending on particle type, energy and fluence. The temporary or permanent damage inflicted by a single particle (single event effect) to electronic devices or integrated circuits is treated separately from the total ionizing dose (TID) effect for which the accumulated fluence causes degradation and from the displacement damage induced by the non-ionizing energy-loss (NIEL) deposition. Understanding of radiation effects on silicon devices has an impact on their design and allows the prediction of a specific device behaviour when exposed to a radiation field of interest

  4. Self-Managing Postoperative Pain with the Use of a Novel, Interactive Device: A Proof of Concept Study

    Directory of Open Access Journals (Sweden)

    Luke Mordecai

    2016-01-01

    Full Text Available Background. Pain is commonly experienced following surgical procedures. Suboptimal management is multifactorial. Objectives. The primary objective was to assess whether patients used a device (Navimed to self-report pain over and above a normal baseline of observations. Secondary outcome measures included comparison of pain scores and patient use of and feedback on the device. Methods. In a prospective randomized controlled trial, elective gynaecological surgery patients received standard postoperative pain care or standard care plus the Navimed, which allowed them to self-report pain and offered interactive self-help options. Results. 52 female patients, 26 in each of device and standard groups, did not differ in the frequency of nurse-documented pain scores or mean pain scores provided to nurses. The device group additionally reported pain on the device (means 18.50 versus 11.90 pain ratings per day, t(32=2.75, p<0.001 that was significantly worse than reported to nurses but retrospectively rated significantly less anxiety. 80% of patients found the device useful. Discussion and Conclusion. This study demonstrates that patients used the Navimed to report pain and to help manage it. Further work is required to investigate the difference in pain scores reported and to develop more sophisticated software.

  5. How do health service professionals consider human factors when purchasing interactive medical devices? A qualitative interview study.

    Science.gov (United States)

    Vincent, Christopher James; Blandford, Ann

    2017-03-01

    We present findings of a UK study into how those involved in purchasing interactive medical devices go about evaluating usability, the challenges that arise, and opportunities for improvement. The study focused on procurement of infusion devices because these are used by various professionals across healthcare. A semi-structured interview study was carried out involving a range of stakeholders (20 in total) involved in or impacted by medical device procurement. Data was analysed using thematic analysis, a qualitative method designed to support the identification, analysis and reporting of patterns. In principle, health service purchasing was found to accommodate consideration of equipment usability. In practice, the evaluation process was driven primarily by engineering standards; assessment of local needs did not accommodate substantive assessment of usability; and choice was limited by the availability of equipment on the marketplace. We discuss ways in which purchasing could be improved through techniques that account for social circumstances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. High Power Microwave Emission of Large and Small Orbit Gyrotron Devices in Rectangular Interaction Structures

    Science.gov (United States)

    Hochman, J. M.; Gilgenbach, R. M.; Jaynes, R. L.; Rintamaki, J. I.; Luginsland, J. W.; Lau, Y. Y.; Spencer, T. A.

    1996-11-01

    Experiments utilize large and small orbit e-beam gyrotron devices in a rectangular-cross-section (RCS) gyrotron. This device is being explored to examine polarization control. Other research issues include pulse shortening, and mode competition. MELBA generates electron beams with parameters of: -800kV, 1-10kA diode current, and 0.5-1.0 μ sec pulselengths. The small orbit gyrotron device is converted to a large orbit experiment by running MELBA's annular electron beam through a magnetic cusp. Initial experiments showed an increase in beam alpha (V_perp/V_par) of a factor of ~ 4 between small and large orbit devices. Experimental results from the RCS gyrotron will be compared for large-orbit and small-orbit electron beams. Beam transport data and frequency measurements will be presented. Computer modeling utilizing the MAGIC and E-gun codes will be shown.

  7. Interactive lectures: Clickers or personal devices? [v1; ref status: indexed, http://f1000r.es/54w

    Directory of Open Access Journals (Sweden)

    Lesley J. Morrell

    2015-03-01

    Full Text Available Audience response systems (‘clickers’ are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost can be overcome using students’ personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using questionnaires, we compare student perceptions of clicker and smartphone based polling systems. We find that students prefer interactive lectures generally, but those that used their own device preferred those lectures over lectures using clickers. However, device users were more likely to report using their devices for other purposes (checking email, social media etc. when they were available to answer polling questions. These students did not feel that this distracted them from the lecture, instead, concerns over the use of smartphones centred around increased battery usage and inclusivity for students without access to suitable technology. Our results suggest that students generally preferred to use their own devices over clickers, and that this may be a sensible way to overcome some of the limitations associated with clickers, although issues surrounding levels of distraction and the implications for retention and recall of information need further investigation.

  8. Effects of iPod Touch™ Technology as Communication Devices on Peer Social Interactions across Environments

    Science.gov (United States)

    Mancil, G. Richmond; Lorah, Elizabeth R.; Whitby, Peggy Schaefer

    2016-01-01

    The purpose of the study was to evaluate the use of the iPod Touch™ as a Speech Generated Device (SGD) for Functional Communication Training (FCT). The evaluation of the effects on problem behavior, the effects on generalization and maintenance of the acquired communication repertoire, and the social initiations of peers between the new SGD (iPod…

  9. Investigation of CPD and HMDS Sample Preparation Techniques for Cervical Cells in Developing Computer-Aided Screening System Based on FE-SEM/EDX

    Science.gov (United States)

    Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system. PMID:25610902

  10. The effect of X-ray irradiation on changes of blood chemistry in RC-MAP and CPD-whole blood after irradiation

    International Nuclear Information System (INIS)

    Hirose, Tetsuhito; Katayama, Norihumi; Okamoto, Yukiharu; Tsuda, Tadaaki; Ota, Kiichiro; Nishioka, Shingo; Tsumura, Michiyo

    1997-01-01

    The Japanese Welfare Ministry recommended to irradiate transfused blood in order to inactivate lymphocytes, thereby preventing from transfusion associated graft-versus-host disease (PT-GVHD). But an adequate dose of irradiation applied to various kinds of transfused blood has not yet known. We investigated the effect of a irradiation dose of 15 Gy (gray) on changes of plasma K, GOT, BUN and total protein (T.P) in RC-MAP (MAP) and CPD added whole blood (CPD) after days of storage of irradiation. There was a significant increase of potassium (K) in plasma in irradiated RC-MAP, compared with those in non-irradiated RC-MAP, after storage from day 2. Plasma K level in irradiated CPD increased more than those in non-irradiated CPD after storage at day 5. No different increases in plasma GOT, BUN and T.P levels were not shown in irradiated RC-MAP and CPD. Our data led to a conclusion that a adequate irradiated dose seemed to be different in various kinds of transfused blood to inactivate lymphocyte for the prevention of PT-GVHD. (author)

  11. Enhancing Human-Computer Interaction Design Education: Teaching Affordance Design for Emerging Mobile Devices

    Science.gov (United States)

    Faiola, Anthony; Matei, Sorin Adam

    2010-01-01

    The evolution of human-computer interaction design (HCID) over the last 20 years suggests that there is a growing need for educational scholars to consider new and more applicable theoretical models of interactive product design. The authors suggest that such paradigms would call for an approach that would equip HCID students with a better…

  12. Kinetic Monte Carlo Modeling of Charge Carriers in Organic Electronic Devices: Suppression of the Self-Interaction Error

    KAUST Repository

    Li, Haoyuan

    2017-05-18

    Kinetic Monte Carlo (KMC) simulations have emerged as an important tool to help improve the efficiency of organic electronic devices by providing a better understanding of their device physics. In the KMC simulation of an organic device, the reliability of the results depends critically on the accuracy of the chosen charge-transfer rates, which are themselves strongly influenced by the site-energy differences. These site-energy differences include components coming from the electrostatic forces present in the system, which are often evaluated through electric potentials described by the Poisson equation. Here we show that the charge-carrier self-interaction errors that appear when evaluating the site-energy differences can lead to unreliable simulation results. To eliminate these errors, we propose two approaches that are also found to reduce the impact of finite-size effects. As a consequence, reliable results can be obtained at reduced computational costs. The proposed methodologies can be extended to other device simulation techniques as well.

  13. Device Process and Circuit Application Interaction for Harsh Electronics: Hf-In-Zn-O Thin Film Transistors as an Example

    KAUST Repository

    Ho, Chih-Hsiang

    2017-06-27

    The effects of Hf content on the radiation hardness of Hf-In-Zn-O thin-film transistors (HIZO TFTs) and HIZO TFTbased circuits are systemically examined. The evaluated circuits, including current-starved ring oscillator, energy harvesting and RF circuits are essential for space electronic systems. It is shown that HIZO TFTs with low Hf concentration have better initial performance while TFTs with high Hf concentration are more stable against radiation. On the other hand, for circuit application, the stable HIZO TFTs are not necessarily preferred for all circuits. The work demonstrates that understanding the device-circuit interactions is necessary for device optimization and circuit reliability improvements for harsh electronic systems.

  14. Device Process and Circuit Application Interaction for Harsh Electronics: Hf-In-Zn-O Thin Film Transistors as an Example

    KAUST Repository

    Ho, Chih-Hsiang; Tsai, Dung-Sheng; Lu, Chao; Kim, Soo Youn; Mungan, Selin; Yang, Shih-Guo; Zhang, Yuanzhi; He, Jr-Hau

    2017-01-01

    The effects of Hf content on the radiation hardness of Hf-In-Zn-O thin-film transistors (HIZO TFTs) and HIZO TFTbased circuits are systemically examined. The evaluated circuits, including current-starved ring oscillator, energy harvesting and RF circuits are essential for space electronic systems. It is shown that HIZO TFTs with low Hf concentration have better initial performance while TFTs with high Hf concentration are more stable against radiation. On the other hand, for circuit application, the stable HIZO TFTs are not necessarily preferred for all circuits. The work demonstrates that understanding the device-circuit interactions is necessary for device optimization and circuit reliability improvements for harsh electronic systems.

  15. Engineering of kinase-based protein interacting devices: active expression of tyrosine kinase domains

    KAUST Repository

    Diaz Galicia, Miriam Escarlet

    2018-01-01

    is then translated into a FRET (Fluorescence Resonance Energy Transfer) signal is here proposed. To this end, DNA constructs for interaction amplification (split kinases), positive controls (intact kinase domains), scaffolding proteins and phosphopeptide - SH2-domain

  16. Dynamic stress of impeller blade of shaft extension tubular pump device based on bidirectional fluid-structure interaction

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Kan; Liu, Huiwen; Yang, Chunxia [Hohai University, Nanjing (China); Zheng, Yuan [National Engineering Research Center of Water Resources Efficient Utilization and Engineering Safety, Nanjing (China); Fu, Shifeng; Zhang, Xin [Power China Huadong Engineering Corporation, Hangzhou (China)

    2017-04-15

    Current research on the stability of tubular pumps is mainly concerned with the transient hydrodynamic characteristics. However, the structural response under the influence of fluid-structure interaction hasn't been taken fully into consideration. The instability of the structure can cause vibration and cracks, which may threaten the safety of the unit. We used bidirectional fluid-structure interaction to comprehensively analyze the dynamic stress characteristics of the impeller blades of the shaft extension tubular pump device. Furthermore, dynamic stress of impeller blade of shaft extension tubular pump device was solved under different lift conditions of 0° blade angle. Based on Reynolds-average N-S equation and SST k-ω turbulence model, numerical simulation was carried out for three-dimensional unsteady incompressible turbulent flow field of the pump device whole flow passage. Meanwhile, the finite element method was used to calculate dynamic characteristics of the blade structure. The blade dynamic stress distribution was obtained on the basis of fourth strength theory. The research results indicate that the maximum blade dynamic stress appears at the joint between root of inlet side of the blade suction surface and the axis. Considering the influence of gravity, the fluctuation of the blade dynamic stress increases initially and decreases afterwards within a rotation period. In the meantime, the dynamic stress in the middle part of inlet edge presents larger relative fluctuation amplitude. Finally, a prediction method for dynamic stress distribution of tubular pump considering fluid-structure interaction and gravity effect was proposed. This method can be used in the design stage of tubular pump to predict dynamic stress distribution of the structure under different operating conditions, improve the reliability of pump impeller and analyze the impeller fatigue life.

  17. Proceedings of US/Japan workshop, Q219 on high heat flux components and plasma surface interactions for next fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Ulrickson, M.A.; Stevens, P.L.; Hino, T.; Hirohata, Y. [eds.

    1996-12-01

    This report contains the viewgraphs from the proceedings of US/Japan Workshop on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices. Some of the general topics covered by this report are: PFC/PSI in tokamak and helical devices; development of high heat flux components; PSIS and plasma facing materials;tritium; and material damage.

  18. Proceedings of US/Japan workshop, Q219 on high heat flux components and plasma surface interactions for next fusion devices

    International Nuclear Information System (INIS)

    Ulrickson, M.A.; Stevens, P.L.; Hino, T.; Hirohata, Y.

    1996-12-01

    This report contains the viewgraphs from the proceedings of US/Japan Workshop on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices. Some of the general topics covered by this report are: PFC/PSI in tokamak and helical devices; development of high heat flux components; PSIS and plasma facing materials;tritium; and material damage

  19. Interaction of dense nitrogen plasma with SS304 surface using APF plasma focus device

    Science.gov (United States)

    Afrashteh, M.; Habibi, M.; Heydari, E.

    2012-04-01

    The nitridation of SS304 surfaces is obtained by irradiating nitrogen ions from Amirkabir plasma focus device, which use multiple focus deposition shots at optimum distance 10 cm from the anode. The Vickers Micro-Hardness values are improved more than twice for the nitrided samples comparing to the nonnitrided ones. The X-ray diffraction (XRD) analysis is carried out in order to explore the phase changes in the near surface structure of the metals. The results of Scanning Electron Microscopy (SEM) indicate changes in surface morphology which are the emergence of smooth and uniform film on the surface of the nitrided metals.

  20. Replication Kits for the papers "Automated Usability Evaluation of Virtual Reality Applications" and "VR Interaction Modalities for the Evaluation of Technical Device Prototypes" submitted to the CHI 2018

    OpenAIRE

    Harms, Patrick; Holderied, Hanna

    2017-01-01

    This replication kit contains all necessary data to reproduce the setup and results of both papers 'Automated Usability Evaluation of Virtual Reality Applications' and 'VR Interaction Modalities for the Evaluation of Technical Device Prototypes' as submitted to the CHI 2018. It includes the Unity Projects that show a coffee machine and a copier scene (sometimes refered to as printer scene, as well, as it is an integrated device) that can be interacted with with the help of the four interactio...

  1. Interactions of DNA with graphene and sensing applications of graphene field-effect transistor devices: A review

    Energy Technology Data Exchange (ETDEWEB)

    Green, Nathaniel S.; Norton, Michael L., E-mail: norton@marshall.edu

    2015-01-01

    Highlights: • The interaction of DNA, including DNA nanostructures, and graphene is reviewed. • Comparison of DNA graphene field-effect transistor (GFET) with other detection methods. • Discussion of challenges present in the detection mechanism of GFETs. • Use of DNA aptamer GFET sensors for the detection of small molecules and proteins. - Abstract: Graphene field-effect transistors (GFET) have emerged as powerful detection platforms enabled by the advent of chemical vapor deposition (CVD) production of the unique atomically thin 2D material on a large scale. DNA aptamers, short target-specific oligonucleotides, are excellent sensor moieties for GFETs due to their strong affinity to graphene, relatively short chain-length, selectivity, and a high degree of analyte variability. However, the interaction between DNA and graphene is not fully understood, leading to questions about the structure of surface-bound DNA, including the morphology of DNA nanostructures and the nature of the electronic response seen from analyte binding. This review critically evaluates recent insights into the nature of the DNA graphene interaction and its affect on sensor viability for DNA, small molecules, and proteins with respect to previously established sensing methods. We first discuss the sorption of DNA to graphene to introduce the interactions and forces acting in DNA based GFET devices and how these forces can potentially affect the performance of increasingly popular DNA aptamers and even future DNA nanostructures as sensor substrates. Next, we discuss the novel use of GFETs to detect DNA and the underlying electronic phenomena that are typically used as benchmarks for characterizing the analyte response of these devices. Finally, we address the use of DNA aptamers to increase the selectivity of GFET sensors for small molecules and proteins and compare them with other, state of the art, detection methods.

  2. Analysis of the interaction of deuterium plasmas with tungsten in the Fuego-Nuevo II device

    Science.gov (United States)

    Ramos, Gonzalo; Castillo, Fermín; Nieto, Martín; Martínez, Marco; Rangel, José; Herrera-Velázquez, Julio

    2012-10-01

    Tungsten is one of the main candidate materials for plasma-facing components in future fusion power plants. The Fuego-Nuevo II, a plasma focus device, which can produce dense magnetized helium and deuterium plasmas, has been adapted to address plasma-facing materials questions. In this paper we present results of tungsten targets exposed to deuterium plasmas in the Fuego Nuevo II device, using different experimental conditions. The plasma generated and accelerated in the coaxial gun is expected to have, before the pinch, energies of the order of hundreds eV and velocities of the order of 40,000 m s-1. At the pinch, the ions are reported to have energies of the order of 1.5 keV at most. The samples, analysed with a scanning electron microscope (SEM) in cross section show a damage profile to depths of the order of 580 nm, which are larger than those expected for ions with 1.5 keV, and may be evidence of ion acceleration. An analysis with the SRIM (Stopping Range of Ions in Matter) package calculations is shown.

  3. The effects of interaction with the device described by procedural text on recall, true/false, and task performance.

    Science.gov (United States)

    Diehl, V A; Mills, C B

    1995-11-01

    In two experiments, subjects interacted to different extents with relevant devices while reading two complex multistep procedural texts and were then tested with task performance time, true/false, and recall measures. While reading, subjects performed the task (read and do), saw the experimenter perform the task (read and see experimenter do), imagined doing the task (read and imagine), looked at the device while reading (read and see), or only read (read only). Van Dijk and Kintsch's (1983) text representation theory led to the prediction that exposure to the task device (in the read-and-do, read-and-see, and read-and-see-experimenter-do conditions) would lead to the development of a stronger situation model and therefore faster task performance, whereas the read-only and read-and-see conditions would lead to a better textbase, and therefore better performance on the true/false and recall tasks. Paivio's (1991) dual coding theory led to the opposite prediction for recall. The results supported the text representation theory with task performance and recall. The read-and-see condition produced consistently good performance on the true/false measure. Amount of text study time contributed to recall performance. These findings support the notion that information available while reading leads to differential development of representations in memory, which, in turn, causes differences in performance on various measures.

  4. Interactive learning environments to support independent learning: the impact of discernability of embedded support devices

    NARCIS (Netherlands)

    Martens, Rob; Valcke, Martin; Portier, Stanley

    2017-01-01

    In this article the effectivity of prototypes of interactive learning environments (ILE) is investigated. These computer-based environments are used for independent learning. In the learning materials, represented in the prototypes, a clear distinction is made between the basic content and embedded

  5. Thumb Reach of Indonesian Young Adult When Interacting with Touchscreen of Single-Handed Device: A Preliminary Study

    Science.gov (United States)

    Umami, M. K.

    2018-01-01

    This study is a preliminary survey on thumb reach of Indonesian population when interacting with single-handed device. This study was aimed to know the thumb reach envelope on the screen of mobile phone. The correlation between the thumb reach vs. the hand length and thumb length was also identified. Thirty young adults participated in the study. All participants had normal body stature and were right-handed person. In the observational phase, the participant was asked to colour the canvas area on the screen of the mobile phone by using his/her thumb. The participant had to complete the task by applying the single hand interaction. The participant should grab the mobile phone as he/she use it normally in his/her daily activities. The thumb reach envelope of participants was identified from the coloured area of the canvas. The results of this study found that participants with a large hand length and thumb length tend to have a large thumb reach. The results of this study also show the thumb reach area of the participants is forming an elliptical shape that runs from the northeast to southwest on the device screen.

  6. Characterizing and modeling protein-surface interactions in lab-on-chip devices

    Science.gov (United States)

    Katira, Parag

    Protein adsorption on surfaces determines the response of other biological species present in the surrounding solution. This phenomenon plays a major role in the design of biomedical and biotechnological devices. While specific protein adsorption is essential for device function, non-specific protein adsorption leads to the loss of device function. For example, non-specific protein adsorption on bioimplants triggers foreign body response, in biosensors it leads to reduced signal to noise ratios, and in hybrid bionanodevices it results in the loss of confinement and directionality of molecular shuttles. Novel surface coatings are being developed to reduce or completely prevent the non-specific adsorption of proteins to surfaces. A novel quantification technique for extremely low protein coverage on surfaces has been developed. This technique utilizes measurement of the landing rate of microtubule filaments on kinesin proteins adsorbed on a surface to determine the kinesin density. Ultra-low limits of detection, dynamic range, ease of detection and availability of a ready-made kinesin-microtubule kit makes this technique highly suitable for detecting protein adsorption below the detection limits of standard techniques. Secondly, a random sequential adsorption model is presented for protein adsorption to PEO-coated surfaces. The derived analytical expressions accurately predict the observed experimental results from various research groups, suggesting that PEO chains act as almost perfect steric barriers to protein adsorption. These expressions can be used to predict the performance of a variety of systems towards resisting protein adsorption and can help in the design of better non-fouling surface coatings. Finally, in biosensing systems, target analytes are captured and concentrated on specifically adsorbed proteins for detection. Non-specific adsorption of proteins results in the loss of signal, and an increase in the background. The use of nanoscale transducers as

  7. 3D interactive augmented reality-enhanced digital learning systems for mobile devices

    Science.gov (United States)

    Feng, Kai-Ten; Tseng, Po-Hsuan; Chiu, Pei-Shuan; Yang, Jia-Lin; Chiu, Chun-Jie

    2013-03-01

    With enhanced processing capability of mobile platforms, augmented reality (AR) has been considered a promising technology for achieving enhanced user experiences (UX). Augmented reality is to impose virtual information, e.g., videos and images, onto a live-view digital display. UX on real-world environment via the display can be e ectively enhanced with the adoption of interactive AR technology. Enhancement on UX can be bene cial for digital learning systems. There are existing research works based on AR targeting for the design of e-learning systems. However, none of these work focuses on providing three-dimensional (3-D) object modeling for en- hanced UX based on interactive AR techniques. In this paper, the 3-D interactive augmented reality-enhanced learning (IARL) systems will be proposed to provide enhanced UX for digital learning. The proposed IARL systems consist of two major components, including the markerless pattern recognition (MPR) for 3-D models and velocity-based object tracking (VOT) algorithms. Realistic implementation of proposed IARL system is conducted on Android-based mobile platforms. UX on digital learning can be greatly improved with the adoption of proposed IARL systems.

  8. Remote handling techniques in decommissioning - A report of the NEA Co-operative Programme on Decommissioning (CPD) project

    International Nuclear Information System (INIS)

    Borchardt, Ralf; Denissen, Luc; Desbats, Philippe; Jeanjacques, Michel; Nokhamzon, Jean-Guy; Valentin, Pierre; Slater, Steve; Valencia, Luis; Wittenauer, Stephan; Yamauchi, Toyoaki; Burton, Bob

    2011-01-01

    The NEA Co-operative Programme for the Exchange of Scientific and Technical Information Concerning Nuclear Installation Decommissioning Projects (CPD) is a joint undertaking of a limited number of organisations actively executing on planning the decommissioning of nuclear facilities. The objective of the CPD is to acquire information from operational experience in decommissioning nuclear installations that is useful for future projects. Although part of the information exchanged within CPD is confidential in nature and is restricted to programme participants, experience of general interest gained under the programme's auspices is released for broader use. Such information is brought to the attention of all NEA members through regular reports to the NEA Radioactive Waste Management Committee (RWMC), as well as through published studies. This report describes generic results obtained by a CPD Task Group analysing the needs for remote technologies. The existing technologies able to meet these needs, the lessons learned and showing where improvements or further developments should be made in this domain. During the D and D process, the handling of highly radioactive materials, the deployment of tools and sensors and the dismantling of components built from many different materials can be a long, labor-intensive process that has the potential for high exposure rates, heat stress and injury to personnel. Mobile robotics systems provide solutions to these hazards. Such remote handling systems are required to perform tasks within budget and on schedule while justifying the expense by a saving in cumulative doses received by project personnel. To reach this goal, the following are additional factors that need to be evaluated when preparing a project: - System and peripherals must be operator-friendly. Ideally, the system must be designed to allow personnel currently available for the D and D project to become trained as operators within a reasonable time frame. - The

  9. Referential Interactions of Turkish-Learning Children with Their Caregivers about Non-Absent Objects: Integration of Non-Verbal Devices and Prior Discourse

    Science.gov (United States)

    Ates, Beyza S.; Küntay, Aylin C.

    2018-01-01

    This paper examines the way children younger than two use non-verbal devices (i.e., deictic gestures and communicative functional acts) and pay attention to discourse status (i.e., prior mention vs. newness) of referents in interactions with caregivers. Data based on semi-naturalistic interactions with caregivers of four children, at ages 1;00,…

  10. Probing Interaction Between Platinum Group Metal (PGM) and Non-PGM Support Through Surface Characterization and Device Performance

    Science.gov (United States)

    Saha, Shibely

    High cost and limited abundance of Platinum (Pt) have hindered effective commercialization of Proton Exchange Membrane Fuel Cell and Electrolyzer. Efforts have been undertaken to reduce precious group metal (PGM) requirement for these devices without compromising the activity of the catalyst by using transition metal carbides (TMC) as non-PGM support thanks to their similar electronic and geometric structures as Pt. In this work Mo2C was selected as non-PGM support and Pt was used as the PGM of interest. We hypothesize that the hollow nanotube morphology of Mo2C support combined with Pt nano particles deposited on it via atomic layer deposition (ALD) technique would allow increased interaction between them which may increase the activity of Pt and Mo2C as well as maximize the Pt active surface area. Specifically, a rotary ALD equipment was used to grow Pt particles from atomic level to 2--3 nanometers by simply adjusting number of ALD cycles in order to probe the interaction between the deposited Pt nanoparticles and Mo2C nanotube support. Interaction between the Pt and Mo2 C was analyzed via surface characterization and electrochemical characterization. Interaction between Pt and Mo2C arises due to the lattice mismatch between Pt and Mo2C as well as electron migration between them. Lattice spacing analysis using high resolution transmission electron microscopy (HRTEM) images, combined with Pt binding energy shift in XPS results, clearly showed strong bonding between Pt nanoparticles and the Mo2C nanotube support in all the resultant Pt/Mo2C samples. We postulate that this strong interaction is responsible for the significantly enhanced durability observed in our constant potential electrolysis (CPE) and accelerated degradation testing (ADT). Of the three samples from different ALD cycles (15, 50 and 100), Mo2C nanotubes modified by 50 (1.07 wt% Pt loading) and 100 cycles (4.4 wt% Pt) of Pt deposition, showed higher HER and HOR activity per Pt mass than commercial

  11. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  12. MasterOnline Periodontology and Implant Therapy-revisited after seven years: A case study of the structures and outcomes in a blended learning CPD.

    Science.gov (United States)

    Ratka-Krüger, P; Wölber, J P; Blank, J; Holst, K; Hörmeyer, I; Vögele, E

    2018-02-01

    There is a great need for postgraduate training and continuing professional development (CPD), specifically in the field of periodontology. Despite the plenty of periodontal CPDs, there is a lack of information about the performance of CPDs in a blended learning setting. This study is a case study of the structures and outcomes in a blended learning CPD programme in periodontology, the MasterOnline Periodontology and Implant Therapy hosted by the University of Freiburg's Dental School. The structures of the blended learning CPD were analysed with the aims to (i) make explicit how various innovative educational methods and ICT tools can be successfully applied to a Web-supported postgraduate periodontology training programme, (ii) identify the programme's impact on learning transfer in students' dental practices and (iii) identify other outcomes, synergies and any changes required during the existence. Using qualitative interviewing, the various types of learning transfer and elements of the study programme that foster transfer could be exemplified. A period of 7 years was analysed. In this duration, 50 students successfully graduated to a master of science. Qualitative interviews were performed with six students and four teachers affirming the learning transfer in a blended learning setting. This case study shows that blended learning can be a successful approach for CPD in dentistry. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Magnetic Field Interactions of Copper-Containing Intrauterine Devices in 3.0-Tesla Magnetic Resonance Imaging: In Vivo Study

    Energy Technology Data Exchange (ETDEWEB)

    Berger-Kulemann, Vanessa; Einspieler, Henrik [Department of Radiology, Medical University of Vienna, Vienna 1090 (Austria); Hachemian, Nilouparak [Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna 1090 (Austria); Prayer, Daniela; Trattnig, Siegfried; Weber, Michael; Ba-Ssalamah, Ahmed [Department of Radiology, Medical University of Vienna, Vienna 1090 (Austria)

    2013-07-01

    An ex vivo study found a copper-containing intrauterine device (IUD) to be safe for women undergoing an MRI examination at a 3.0-T field. No significant artifacts caused by the metallic implant were detected. However, there are still no in vivo data about these concerns. The aim of this study was to evaluate 3.0-T magnetic field interactions of copper-containing IUDs in vivo. Magnetic field interactions and potential adverse events were evaluated in 33 women using a questionnaire-based telephone survey. Two experienced radiologists performed artifact evaluation on MR images of the pelvis. Eighteen patients were eligible for the survey. One patient reported a dislocation of the IUD after the MR examination. All other patients had no signs of field interactions. No IUD-related artifacts were found. MRI at 3.0-T is possible for women with copper-containing IUDs. However, consulting a gynecologist to check the correct position of the IUD and exclude complications after an MR examination is highly recommended. High-quality clinical imaging of the female pelvis can be performed without a loss in image quality.

  14. Magnetic Field Interactions of Copper-Containing Intrauterine Devices in 3.0-Tesla Magnetic Resonance Imaging: In Vivo Study

    International Nuclear Information System (INIS)

    Berger-Kulemann, Vanessa; Einspieler, Henrik; Hachemian, Nilouparak; Prayer, Daniela; Trattnig, Siegfried; Weber, Michael; Ba-Ssalamah, Ahmed

    2013-01-01

    An ex vivo study found a copper-containing intrauterine device (IUD) to be safe for women undergoing an MRI examination at a 3.0-T field. No significant artifacts caused by the metallic implant were detected. However, there are still no in vivo data about these concerns. The aim of this study was to evaluate 3.0-T magnetic field interactions of copper-containing IUDs in vivo. Magnetic field interactions and potential adverse events were evaluated in 33 women using a questionnaire-based telephone survey. Two experienced radiologists performed artifact evaluation on MR images of the pelvis. Eighteen patients were eligible for the survey. One patient reported a dislocation of the IUD after the MR examination. All other patients had no signs of field interactions. No IUD-related artifacts were found. MRI at 3.0-T is possible for women with copper-containing IUDs. However, consulting a gynecologist to check the correct position of the IUD and exclude complications after an MR examination is highly recommended. High-quality clinical imaging of the female pelvis can be performed without a loss in image quality

  15. Interaction of powerful hot plasma and fast ion streams with materials in dense plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Gribkov, V.A. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Kowalska-Strzeciwilk, E.; Kubkowska, M.; Miklaszewski, R.; Paduch, M.; Pisarczyk, T.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Demina, E.V.; Pimenov, V.N.; Maslyaev, S.A. [Institution of Russian Academy of Sciences A.A. Baikov Institute of Metallurgy and Material Science RAS, Moscow (Russian Federation); Bondarenko, G.G. [National Research University Higher School of Economics (HSE), Moscow (Russian Federation); Vilemova, M.; Matejicek, J. [Institute of Plasma Physics of the CAS, Prague (Czech Republic)

    2016-12-15

    Highlights: • Materials perspective for use in mainstream nuclear fusion facilities were studied. • Powerful streams of hot plasma and fast ions were used to induce irradiation. • High temporal, spatial, angular and spectral resolution available in experiments. • Results of irradiation were investigated by number of analysis techniques. - Abstract: A process of irradiating and ablating solid-state targets with hot plasma and fast ion streams in two Dense Plasma Focus (DPF) devices – PF-6 and PF-1000 was examined by applying a number of diagnostics of nanosecond time resolution. Materials perspective for use in chambers of the mainstream nuclear fusion facilities (mainly with inertial plasma confinement like NIF and Z-machine), intended both for the first wall and for constructions, have been irradiated in these simulators. Optical microscopy, SEM, Atomic Emission Spectroscopy, images in secondary electrons and in characteristic X-ray luminescence of different elements, and X-ray elemental analysis, gave results on damageability for a number of materials including low-activated ferritic and austenitic stainless steels, β-alloy of Ti, as well as two types of W and a composite on its base. With an increase of the number of shots irradiating the surface, its morphology changes from weakly pronounced wave-like structures or ridges to strongly developed ones. At later stages, due to the action of the secondary plasma produced near the target materials they melted, yielding both blisters and a fracturing pattern: first along the grain and then “in-between” the grains creating an intergranular net of microcracks. At the highest values of power flux densities multiple bubbles appeared. Furthermore, in this last case the cracks were developed because of microstresses at the solidification of melt. Presence of deuterium within the irradiated ferritic steel surface nanolayers is explained by capture of deuterons in lattice defects of the types of impurity atoms

  16. Critical plasma-wall interaction issues for plasma-facing materials and components in near-term fusion devices

    International Nuclear Information System (INIS)

    Federici, G.; Coad, J.P.; Haasz, A.A.; Janeschitz, G.; Noda, N.; Philipps, V.; Roth, J.; Skinner, C.H.; Tivey, R.; Wu, C.H.

    2000-01-01

    The increase in pulse duration and cumulative run-time, together with the increase of the plasma energy content, will represent the largest changes in operation conditions in future fusion devices such as the International Thermonuclear Experimental Reactor (ITER) compared to today's experimental facilities. These will give rise to important plasma-physics effects and plasma-material interactions (PMIs) which are only partially observed and accessible in present-day experiments and will open new design, operation and safety issues. For the first time in fusion research, erosion and its consequences over many pulses (e.g., co-deposition and dust) may determine the operational schedule of a fusion device. This paper identifies the most critical issues arising from PMIs which represent key elements in the selection of materials, the design, and the optimisation of plasma-facing components (PFCs) for the first-wall and divertor. Significant advances in the knowledge base have been made recently, as part of the R and D supporting the engineering design activities (EDA) of ITER, and some of the most relevant data are reviewed here together with areas where further R and D work is urgently needed

  17. Exploring Light’s Interactions with Bubbles and Light Absorbers in Photoelectrochemical Devices using Ray Tracing

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, John Colby [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). The Joint Center for Artificial Photosynthesis; Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering

    2012-12-01

    Ray tracing was used to perform optical optimization of arrays of photovoltaic microrods and explore the interaction between light and bubbles of oxygen gas on the surface of the microrods. The incident angle of light was varied over a wide range. The percent of incident light absorbed by the microrods and reflected by the bubbles was computed over this range. It was found that, for the 10 μm diameter, 100 μm tall SrTiO3 microrods simulated in the model, the optimal center-­to-­center spacing was 14 μm for a square grid. This geometry produced 75% average and 90% maximum absorbance. For a triangular grid using the same microrods, the optimal center-­to-­center spacing was 14 μm. This geometry produced 67% average and 85% maximum absorbance. For a randomly laid out grid of 5 μm diameter, 100 μm tall SrTiO3 microrods with an average center-­to-­center spacing of 20 μm, the average absorption was 23% and the maximum absorption was 43%. For a 50% areal coverage fraction of bubbles on the absorber surface, between 2%-­20% of the incident light energy was reflected away from the rods by the bubbles, depending upon incident angle and bubble morphology.

  18. Enzyme-semiconductor interactions: Routes from fundamental aspects to photoactive devices

    Energy Technology Data Exchange (ETDEWEB)

    Lewerenz, H.J. [Division of Solar Energy, Hahn-Meitner-Institut GmbH, Berlin (Germany)

    2008-09-15

    Scanning tunnelling microscopy (STM) experiments at protein-semiconductor systems are analyzed using concepts from applied semiconductor physics such as Fermi level pinning and MIS (metal-insulator-semiconductor) junction electronics. Routes for immobilization of enzymes (proteins) on nanostructured surfaces of MoTe{sub 2} and Si are outlined using so-called DLVO and non-DLVO interaction forces. An overview of the catalytic activity of the imaged enzymes, reverse transcriptases of the retroviruses HIV 1 and AMV (avian myeloblastosis virus), is given including their tertiary structural properties which is revealed also in the STM and tapping mode AFM images. For the interpretation of STM images, a resonant charge transfer mechanism is invoked, based on the potential dependence of the image contrast and the energy band structure of MoTe{sub 2} near the valence band maximum. First analyses of the charge transport from the semiconductor to the STM tip at negative bias of MoTe{sub 2} suggest that the observed uninhibited conductivity in the constant current experiments results from solvation-assisted release of electrons from traps that exist along the polypeptide chains and that charge transport occurs at the circumference of the enzymes where biological water is present. Therefore, charge injection into catalytically active enzymes such as hydrogenase or water oxidase of photosystem I and II with subsequent charge transport to the active sites appears difficult to realize. Possibilities of radiation-less long-distance energy transfer based on the Foerster mechanism, its multichromic extension and on Dexter exciton hopping are considered for catalytically active hybrid inorganic/organic absorber-enzyme structures. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Investigation of compact toroid penetration for fuelling spherical tokamak plasmas on CPD

    International Nuclear Information System (INIS)

    Fukumoto, N.; Hanada, K.; Kawakami, S.

    2008-10-01

    In previous Compact Toroid (CT) injection experiments on several tokamaks, although CT fuelling had been successfully demonstrated, the CT fuelling process has been not clear yet. We have thus conducted CT injection into simple toroidal or vertical vacuum magnetic fields to investigate quantitatively dynamics of CT plasmoid in the penetration process on a spherical tokamak (ST) device. Understanding the process allows us to address appropriately one of the critical issues for practical application of CT injection on reactor-grade tokamaks. In the experiment, the CT shift amount of about 0.26 m in a vertical magnetic field has been observed by using a fast camera. In addition to toroidal magnetic field, vertical one appears to affect CT trajectory in not conventional tokamak but ST devices operated at rather low toroidal fields. We have also observed CT attacks on the target plate with an IR camera. The IR image has indicated that CT shifts 39 mm at the toroidal field of 261 G. From the calorimetric measurement, an input energy due to CT impact in vacuum without magnetic fields is also estimated to be 530 J, which agrees with the initial CT kinetic energy. (author)

  20. D Virtual CH Interactive Information Systems for a Smart Web Browsing Experience for Desktop Pcs and Mobile Devices

    Science.gov (United States)

    Scianna, A.; La Guardia, M.

    2018-05-01

    Recently, the diffusion of knowledge on Cultural Heritage (CH) has become an element of primary importance for its valorization. At the same time, the diffusion of surveys based on UAV Unmanned Aerial Vehicles (UAV) technologies and new methods of photogrammetric reconstruction have opened new possibilities for 3D CH representation. Furthermore the recent development of faster and more stable internet connections leads people to increase the use of mobile devices. In the light of all this, the importance of the development of Virtual Reality (VR) environments applied to CH is strategic for the diffusion of knowledge in a smart solution. In particular, the present work shows how, starting from a basic survey and the further photogrammetric reconstruction of a cultural good, is possible to built a 3D CH interactive information system useful for desktop and mobile devices. For this experimentation the Arab-Norman church of the Trinity of Delia (in Castelvetrano-Sicily-Italy) has been adopted as case study. The survey operations have been carried out considering different rapid methods of acquisition (UAV camera, SLR camera and smartphone camera). The web platform to publish the 3D information has been built using HTML5 markup language and WebGL JavaScript libraries (Three.js libraries). This work presents the construction of a 3D navigation system for a web-browsing of a virtual CH environment, with the integration of first person controls and 3D popup links. This contribution adds a further step to enrich the possibilities of open-source technologies applied to the world of CH valorization on web.

  1. 3D Virtual CH Interactive Information Systems for a smart web browsing experience for desktop PCs and mobile devices

    Directory of Open Access Journals (Sweden)

    A. Scianna

    2018-05-01

    Full Text Available Recently, the diffusion of knowledge on Cultural Heritage (CH has become an element of primary importance for its valorization. At the same time, the diffusion of surveys based on UAV Unmanned Aerial Vehicles (UAV technologies and new methods of photogrammetric reconstruction have opened new possibilities for 3D CH representation. Furthermore the recent development of faster and more stable internet connections leads people to increase the use of mobile devices. In the light of all this, the importance of the development of Virtual Reality (VR environments applied to CH is strategic for the diffusion of knowledge in a smart solution. In particular, the present work shows how, starting from a basic survey and the further photogrammetric reconstruction of a cultural good, is possible to built a 3D CH interactive information system useful for desktop and mobile devices. For this experimentation the Arab-Norman church of the Trinity of Delia (in Castelvetrano-Sicily-Italy has been adopted as case study. The survey operations have been carried out considering different rapid methods of acquisition (UAV camera, SLR camera and smartphone camera. The web platform to publish the 3D information has been built using HTML5 markup language and WebGL JavaScript libraries (Three.js libraries. This work presents the construction of a 3D navigation system for a web-browsing of a virtual CH environment, with the integration of first person controls and 3D popup links. This contribution adds a further step to enrich the possibilities of open-source technologies applied to the world of CH valorization on web.

  2. An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices.

    Science.gov (United States)

    Hartwig, Zachary S; Barnard, Harold S; Lanza, Richard C; Sorbom, Brandon N; Stahle, Peter W; Whyte, Dennis G

    2013-12-01

    This paper presents a novel particle accelerator-based diagnostic that nondestructively measures the evolution of material surface compositions inside magnetic fusion devices. The diagnostic's purpose is to contribute to an integrated understanding of plasma-material interactions in magnetic fusion, which is severely hindered by a dearth of in situ material surface diagnosis. The diagnostic aims to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. Our instrument uses a compact (~1 m), high-current (~1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak at MIT. We control the tokamak magnetic fields--in between plasma shots--to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes ~5 μm into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. An overview of the diagnostic technique, known as accelerator-based in situ materials surveillance (AIMS), and the first AIMS diagnostic on the Alcator C-Mod tokamak is given. Experimental validation is shown to demonstrate that an optimized deuteron beam is injected into the tokamak, that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. The first AIMS analysis, which measures the relative change in deuterium at a single surface location at the end of the Alcator C-Mod FY2012 plasma campaign, is also presented.

  3. Knowledge, Beliefs and Attitudes of Patients and the General Public towards the Interactions of Physicians with the Pharmaceutical and the Device Industry: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Racha Fadlallah

    Full Text Available To systematically review the evidence on the knowledge, beliefs, and attitudes of patients and the general public towards the interactions of physicians with the pharmaceutical and the device industry.We included quantitative and qualitative studies addressing any type of interactions between physicians and the industry. We searched MEDLINE and EMBASE in August 2015. Two reviewers independently completed data selection, data extraction and assessment of methodological features. We summarized the findings narratively stratified by type of interaction, outcome and country.Of the 11,902 identified citations, 20 studies met the eligibility criteria. Many studies failed to meet safeguards for protecting from bias. In studies focusing on physicians and the pharmaceutical industry, the percentages of participants reporting awareness was higher for office-use gifts relative to personal gifts. Also, participants were more accepting of educational and office-use gifts compared to personal gifts. The findings were heterogeneous for the perceived effects of physician-industry interactions on prescribing behavior, quality and cost of care. Generally, participants supported physicians' disclosure of interactions through easy-to-read printed documents and verbally. In studies focusing on surgeons and device manufacturers, the majority of patients felt their care would improve or not be affected if surgeons interacted with the device industry. Also, they felt surgeons would make the best choices for their health, regardless of financial relationship with the industry. Participants generally supported regulation of surgeon-industry interactions, preferably through professional rather than governmental bodies.The awareness of participants was low for physicians' receipt of personal gifts. Participants also reported greater acceptability and fewer perceived influence for office-use gifts compared to personal gifts. Overall, there appears to be lower awareness

  4. Knowledge, Beliefs and Attitudes of Patients and the General Public towards the Interactions of Physicians with the Pharmaceutical and the Device Industry: A Systematic Review.

    Science.gov (United States)

    Fadlallah, Racha; Nas, Hala; Naamani, Dana; El-Jardali, Fadi; Hammoura, Ihsan; Al-Khaled, Lina; Brax, Hneine; Kahale, Lara; Akl, Elie A

    2016-01-01

    To systematically review the evidence on the knowledge, beliefs, and attitudes of patients and the general public towards the interactions of physicians with the pharmaceutical and the device industry. We included quantitative and qualitative studies addressing any type of interactions between physicians and the industry. We searched MEDLINE and EMBASE in August 2015. Two reviewers independently completed data selection, data extraction and assessment of methodological features. We summarized the findings narratively stratified by type of interaction, outcome and country. Of the 11,902 identified citations, 20 studies met the eligibility criteria. Many studies failed to meet safeguards for protecting from bias. In studies focusing on physicians and the pharmaceutical industry, the percentages of participants reporting awareness was higher for office-use gifts relative to personal gifts. Also, participants were more accepting of educational and office-use gifts compared to personal gifts. The findings were heterogeneous for the perceived effects of physician-industry interactions on prescribing behavior, quality and cost of care. Generally, participants supported physicians' disclosure of interactions through easy-to-read printed documents and verbally. In studies focusing on surgeons and device manufacturers, the majority of patients felt their care would improve or not be affected if surgeons interacted with the device industry. Also, they felt surgeons would make the best choices for their health, regardless of financial relationship with the industry. Participants generally supported regulation of surgeon-industry interactions, preferably through professional rather than governmental bodies. The awareness of participants was low for physicians' receipt of personal gifts. Participants also reported greater acceptability and fewer perceived influence for office-use gifts compared to personal gifts. Overall, there appears to be lower awareness, less concern and

  5. Double-step processes in the 12C(p,d)11C reaction at 45 MeV

    International Nuclear Information System (INIS)

    Couvert, Pierre.

    1974-01-01

    12 C(p,d) 11 C pick-up reaction was performed with a 45 MeV proton beam. A 130keV energy resolution was obtained and angular distributions of nine of the ten first levels of 11 C have been extracted within a large angular range. Assuming only neutron direct transfert, the strong relative excitation of high spin levels cannot be reproduced by a DWBA analysis. The double-step process assumption seems to be verified by a systematical analysis of the (p,d) reaction mechanisms. This analysis is done in the coupled-channel formalism for the five first negative parity states of 11 C. The 3/2 - ground state is essentially populated by the direct transfer of a Psub(3/2) neutron. The contribution of a double-step process, via the 2 + inelastic excitation of 12 C, is important for the four other states. A mechanism which assumes a deuteron inelastic scattering on the 11 C final nucleus after the neutron transfer cannot be neglected and improves the fits when it is taken into account [fr

  6. Teacher Professional Competency Analysis: Implementation Aspect of Continuous Professional Development (CPD

    Directory of Open Access Journals (Sweden)

    Annisa Vidya Safitri

    2017-09-01

    Full Text Available The purpose of this study was to identify the practice of teacher reflection as the basis for the implementation of Sustainable Professionalism (PKB program based on Permendiknas No. 16/2007 at SMKN 2 Kediri. This research is qualitative with phenomenology design. The informants of this research are principal, productive teacher of marketing, vice principal, teacher and marketing teacher. Technique of data collecting done by in-depth interview and documentation. The validity of the data using technique triangulation and source. Data analysis using Miles and Huberman interactive models, extension of observation, and referential adequacy. The results showed that the reflection was not used as the basis of CLA and the teachers did not implement the CLA planning. Elements of PKB activities have been in accordance with the guidelines of self-development and scientific publications. PKB activities have an impact on teacher groups that discuss research issues, more varied and contextual KBM, and administrative demands for teachers.

  7. MEVA--An Interactive Visualization Application for Validation of Multifaceted Meteorological Data with Multiple 3D Devices.

    Directory of Open Access Journals (Sweden)

    Carolin Helbig

    Full Text Available To achieve more realistic simulations, meteorologists develop and use models with increasing spatial and temporal resolution. The analyzing, comparing, and visualizing of resulting simulations becomes more and more challenging due to the growing amounts and multifaceted character of the data. Various data sources, numerous variables and multiple simulations lead to a complex database. Although a variety of software exists suited for the visualization of meteorological data, none of them fulfills all of the typical domain-specific requirements: support for quasi-standard data formats and different grid types, standard visualization techniques for scalar and vector data, visualization of the context (e.g., topography and other static data, support for multiple presentation devices used in modern sciences (e.g., virtual reality, a user-friendly interface, and suitability for cooperative work.Instead of attempting to develop yet another new visualization system to fulfill all possible needs in this application domain, our approach is to provide a flexible workflow that combines different existing state-of-the-art visualization software components in order to hide the complexity of 3D data visualization tools from the end user. To complete the workflow and to enable the domain scientists to interactively visualize their data without advanced skills in 3D visualization systems, we developed a lightweight custom visualization application (MEVA - multifaceted environmental data visualization application that supports the most relevant visualization and interaction techniques and can be easily deployed. Specifically, our workflow combines a variety of different data abstraction methods provided by a state-of-the-art 3D visualization application with the interaction and presentation features of a computer-games engine. Our customized application includes solutions for the analysis of multirun data, specifically with respect to data uncertainty and

  8. [Coupled Analysis of Fluid-Structure Interaction of a Micro-Mechanical Valve for Glaucoma Drainage Devices].

    Science.gov (United States)

    Siewert, S; Sämann, M; Schmidt, W; Stiehm, M; Falke, K; Grabow, N; Guthoff, R; Schmitz, K-P

    2015-12-01

    Glaucoma is the leading cause of irreversible blindness worldwide. In therapeutically refractory cases, alloplastic glaucoma drainage devices (GDD) are being increasingly used to decrease intraocular pressure. Current devices are mainly limited by fibrotic encapsulation and postoperative hypotension. Preliminary studies have described the development of a glaucoma microstent to control aqueous humour drainage from the anterior chamber into the suprachoroidal space. One focus of these studies was on the design of a micro-mechanical valve placed in the anterior chamber to inhibit postoperative hypotension. The present report describes the coupled analysis of fluid-structure interaction (FSI) as basis for future improvements in the design micro-mechanical valves. FSI analysis was carried out with ANSYS 14.5 software. Solid and fluid geometry were combined in a model, and the corresponding material properties of silicone (Silastic Rx-50) and water at room temperature were assigned. The meshing of the solid and fluid domains was carried out in accordance with the results of a convergence study with tetrahedron elements. Structural and fluid mechanical boundary conditions completed the model. The FSI analysis takes into account geometric non-linearity and adaptive remeshing to consider changing geometry. A valve opening pressure of 3.26 mmHg was derived from the FSI analysis and correlates well with the results of preliminary experimental fluid mechanical studies. Flow resistance was calculated from non-linear pressure-flow characteristics as 8.5 × 10(-3) mmHg/µl  · min(-1) and 2.7 × 10(-3) mmHg/µl  · min(-1), respectively before and after valve opening pressure is exceeded. FSI analysis indicated leakage flow before valve opening, which is due to the simplified model geometry. The presented bidirectional coupled FSI analysis is a powerful tool for the development of new designs of micro-mechanical valves for GDD and may help to minimise the time and cost

  9. Distance-Based Tear Lactoferrin Assay on Microfluidic Paper Device Using Interfacial Interactions on Surface-Modified Cellulose.

    Science.gov (United States)

    Yamada, Kentaro; Henares, Terence G; Suzuki, Koji; Citterio, Daniel

    2015-11-11

    "Distance-based" detection motifs on microfluidic paper-based analytical devices (μPADs) allow quantitative analysis without using signal readout instruments in a similar manner to classical analogue thermometers. To realize a cost-effective and calibration-free distance-based assay of lactoferrin in human tear fluid on a μPAD not relying on antibodies or enzymes, we investigated the fluidic mobilities of the target protein and Tb(3+) cations used as the fluorescent detection reagent on surface-modified cellulosic filter papers. Chromatographic elution experiments in a tear-like sample matrix containing electrolytes and proteins revealed a collapse of attractive electrostatic interactions between lactoferrin or Tb(3+) and the cellulosic substrate, which was overcome by the modification of the paper surface with the sulfated polysaccharide ι-carrageenan. The resulting μPAD based on the fluorescence emission distance successfully analyzed 0-4 mg mL(-1) of lactoferrin in complex human tear matrix with a lower limit of detection of 0.1 mg mL(-1) by simple visual inspection. Assay results of 18 human tear samples including ocular disease patients and healthy volunteers showed good correlation to the reference ELISA method with a slope of 0.997 and a regression coefficient of 0.948. The distance-based quantitative signal and the good batch-to-batch fabrication reproducibility relying on printing methods enable quantitative analysis by simply reading out "concentration scale marks" printed on the μPAD without performing any calibration and using any signal readout instrument.

  10. Precision measurements in the weak interaction framework: development of realistic simulations for the LPCTrap device installed at GANIL

    International Nuclear Information System (INIS)

    Fabian, Xavier

    2015-01-01

    This work belongs to the effort presently deployed to measure the angular correlation parameter a_β_ν in three nuclear beta decays ("6He"+, "3"5Ar"+ and "1"9Ne"+). The V-A structure of the weak interaction implies that a_β_ν = +1 for a pure Fermi transition and a_β_ν = -1/3 for a pure Gamow-Teller transition. A thorough measurement of this parameter to check any deviation from these values may lead to the discovery of possible exotic currents. Furthermore, the measurement of a_β_ν in mirror transitions allows the extraction of V_u_d, the first element of the Cabibbo-Kobayashi-Maskawa (CKM) matrix. The LPCTrap apparatus, installed at GANIL, is designed to ready a continuous ion beam for injection in a dedicated Paul trap. This latter device allows to have a quasi-punctual source from which the decay products are detected in coincidence. It is from the study of the recoil ion time-of-flight (TOF) distribution that a_β_ν is withdrawn and, since 2010, the associated Shake-Off (SO) probabilities. This study requires the complete simulation of the LPCTrap experiments. The major part of this work is dedicated to such simulations, especially to the modeling of the trapped ion cloud dynamic. The Clouda program, which takes advantage of graphics processing unit (GPU), was developed in this context and its full characterization is presented here. Three important aspects are addressed: the electromagnetic trapping field, the realistic collisions between the ions and the buffer gas atoms and the space charge effect. The present work shows the importance of these simulations to increase the control of the systematic errors on a_β_ν. (author) [fr

  11. Proceedings of 1999 U.S./Japan Workshop (99FT-05) On High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices

    Energy Technology Data Exchange (ETDEWEB)

    NYGREN,RICHARD E.; STAVROS,DIANA T.

    2000-06-01

    The 1999 US-Japan Workshop on High Heat Flux Components and Plasma Surface Interactions in Next Step Fusion Devices was held at the St. Francis Hotel in Santa Fe, New Mexico, on November 1-4, 1999. There were 42 presentations as well as discussion on technical issues and planning for future collaborations. The participants included 22 researchers from Japan and the United States as well as seven researchers from Europe and Russia. There have been important changes in the programs in both the US and Japan in the areas of plasma surface interactions and plasma facing components. The US has moved away from a strong focus on the ITER Project and has introduced new programs on use of liquid surfaces for plasma facing components, and operation of NSTX has begun. In Japan, the Large Helical Device began operation. This is the first large world-class confinement device operating in a magnetic configuration different than a tokamak. In selecting the presentations for this workshop, the organizers sought a balance between research in laboratory facilities or confinement devices related to plasma surface interactions and experimental research in the development of plasma facing components. In discussions about the workshop itself, the participants affirmed their preference for a setting where ''work-in-progress'' could be informally presented and discussed.

  12. Proceedings of 1999 U.S./Japan Workshop (99FT-05) On High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices

    International Nuclear Information System (INIS)

    NYGREN, RICHARD E.; STAVROS, DIANA T.

    2000-01-01

    The 1999 US-Japan Workshop on High Heat Flux Components and Plasma Surface Interactions in Next Step Fusion Devices was held at the St. Francis Hotel in Santa Fe, New Mexico, on November 1-4, 1999. There were 42 presentations as well as discussion on technical issues and planning for future collaborations. The participants included 22 researchers from Japan and the United States as well as seven researchers from Europe and Russia. There have been important changes in the programs in both the US and Japan in the areas of plasma surface interactions and plasma facing components. The US has moved away from a strong focus on the ITER Project and has introduced new programs on use of liquid surfaces for plasma facing components, and operation of NSTX has begun. In Japan, the Large Helical Device began operation. This is the first large world-class confinement device operating in a magnetic configuration different than a tokamak. In selecting the presentations for this workshop, the organizers sought a balance between research in laboratory facilities or confinement devices related to plasma surface interactions and experimental research in the development of plasma facing components. In discussions about the workshop itself, the participants affirmed their preference for a setting where ''work-in-progress'' could be informally presented and discussed

  13. Creating Live Interactions to Mitigate Barriers (CLIMB): A Mobile Intervention to Improve Social Functioning in People With Chronic Psychotic Disorders

    Science.gov (United States)

    Schlosser, Danielle; Nahum, Mor

    2016-01-01

    Background Numerous psychosocial interventions for individuals with chronic psychotic disorders (CPD) have shown positive effects on social cognitive and functional outcome measures. However, access to and engagement with these interventions remains limited. This is partly because these interventions require specially trained therapists, are not available in all clinical settings, and have a high scheduling burden for participants, usually requiring a commitment of several weeks. Delivering interventions remotely via mobile devices may facilitate access, improve scheduling flexibility, and decrease participant burden, thus improving adherence to intervention requirements. To address these needs, we designed the Creating Live Interactions to Mitigate Barriers (CLIMB) digital intervention, which aims to enhance social functioning in people with CPD. CLIMB consists of two treatment components: a computerized social cognition training (SCT) program and optimized remote group therapy (ORGT). ORGT is an innovative treatment that combines remote group therapy with group texting (short message service, SMS). Objectives The objectives of this single-arm study were to investigate the feasibility of delivering 6 weeks of CLIMB to people with CPD and explore the initial effects on outcomes. Methods Participants were recruited, screened and enrolled via the Internet, and delivered assessments and interventions remotely using provided tablets (iPads). Participants were asked to complete 18 hours of SCT and to attend 6 remote group therapy sessions. To assess feasibility, adherence to study procedures, attrition rates, engagement metrics, and acceptability of the intervention were evaluated. Changes on measures of social cognition, quality of life, and symptoms were also explored. Results In total, 27 participants were enrolled over 12 months. Remote assessments were completed successfully on 96% (26/27) of the enrolled participants. Retention in the 6-week trial was 78% (21

  14. QUEST for sustainable CPD

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund

    2014-01-01

    . The participants rated their overall benefits from phase 1 as rather high. They reported that they tried out models, tools and activities from the course modules in their own classrooms, and in collaboration with colleagues. This is confirmed by observations. In relation to developing a collaborative culture...

  15. Interacting with mobile devices by fusion eye and hand gestures recognition systems based on decision tree approach

    Science.gov (United States)

    Elleuch, Hanene; Wali, Ali; Samet, Anis; Alimi, Adel M.

    2017-03-01

    Two systems of eyes and hand gestures recognition are used to control mobile devices. Based on a real-time video streaming captured from the device's camera, the first system recognizes the motion of user's eyes and the second one detects the static hand gestures. To avoid any confusion between natural and intentional movements we developed a system to fuse the decision coming from eyes and hands gesture recognition systems. The phase of fusion was based on decision tree approach. We conducted a study on 5 volunteers and the results that our system is robust and competitive.

  16. Interactions of aquatic animals with the ORPC OCGen® in Cobscook Bay, Maine: Monitoring behavior change and assessing the probability of encounter with a deployed MHK device

    Energy Technology Data Exchange (ETDEWEB)

    Zydlewski, Gayle Barbin [Univ. of Maine, Orono, ME (United States). School of Marine Sciences; Staines, Garrett [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Viehman, Haley [Acadia Univ., Wolfville, NS (Canada); Shen, Haixue [Louisiana State Univ., Baton Rouge, LA (United States); Altenritter, Megan [Univ. of Maine, Orono, ME (United States)

    2016-10-19

    Commercial viability of the marine hydrokinetic (MHK) energy industry is contingent on numerous and diverse factors. A major factor is the effects deployed devices have on animals. This factor is multi-faceted since it is dependent on the availability of appropriate scientific approaches to detect these effects. One of the animal groups with overlapping distributions of MHK devices are fishes. As such, individual fish behavior is likely to be influenced by the presence and operation of MHK devices. Depending on the scale of deployment there are implications for changes to essential fish habitat and effects that can be explored during deployment of a single device yet most changes are likely to be realized when multiple devices are deployed over large areas. It is not only important to document these effects and examine the need for mitigation, but also determine whether the methods involved can be used within the economic constraints of this nascent industry. The results presented in this report benefit the MHK industry by providing transferrable environmental monitoring approaches for MHK projects, specifically related to the interactions between static and dynamic tidal turbines and fish. In addition, some of the data can be used to generalize conditions (e.g., the temporal periodicity of fish presence in tidal regions and probability of fish encountering a device) at other MHK sites with similar physical conditions and fish assemblages. Ocean Renewable Power Company, LLC (ORPC) deployed and tested a prototype OCGen® tidal module in Cobscook Bay, Maine, in the summer of 2014. University of Maine researchers proposed an approach to inform other researchers, regulators, and industry members of the effects of this deployment on fish. While the approach was specifically applied to the OCGen® module, results are applicable to other pilot projects and inform future array deployments. Research funded under this grant allowed us to quantify fish presence as well as

  17. Performance of the Sellick maneuver significantly improves when residents and trained nurses use a visually interactive guidance device in simulation

    International Nuclear Information System (INIS)

    Connor, Christopher W; Saffary, Roya; Feliz, Eddy

    2013-01-01

    We examined the proper performance of the Sellick maneuver, a maneuver used to reduce the risk of aspiration of stomach contents during induction of general anesthesia, using a novel device that measures and visualizes the force applied to the cricoid cartilage using thin-film force sensitive resistors in a form suitable for in vivo use. Performance was tested in three stages with twenty anaesthesiology residents and twenty trained operating room nurses. Firstly, subjects applied force to the cricoid cartilage as was customary to them. Secondly, subjects used the device to guide the application of that force. Thirdly, subjects were again asked to perform the manoeuvre without visual guidance. Each test lasted 1 min and the amount of force applied was measured throughout. Overall, the Sellick maneuver was often not applied properly, with large variance between individual subjects. Performance and inter-subject consistency improved to a very highly significant degree when subjects were able to use the device as a visual guide (p < 0.001). Subsequent significant improvements in performances during the last, unguided test demonstrated that the device initiated learning. (paper)

  18. Game Design Narrative for Learning: Appropriating Adventure Game Design Narrative Devices and Techniques for the Design of Interactive Learning Environments

    Science.gov (United States)

    Dickey, Michele D.

    2006-01-01

    The purpose of this conceptual analysis is to investigate how contemporary video and computer games might inform instructional design by looking at how narrative devices and techniques support problem solving within complex, multimodal environments. Specifically, this analysis presents a brief overview of game genres and the role of narrative in…

  19. Performance of the Sellick maneuver significantly improves when residents and trained nurses use a visually interactive guidance device in simulation

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Christopher W; Saffary, Roya; Feliz, Eddy [Department of Anesthesiology Boston Medical Center, Boston, MA (United States)

    2013-12-15

    We examined the proper performance of the Sellick maneuver, a maneuver used to reduce the risk of aspiration of stomach contents during induction of general anesthesia, using a novel device that measures and visualizes the force applied to the cricoid cartilage using thin-film force sensitive resistors in a form suitable for in vivo use. Performance was tested in three stages with twenty anaesthesiology residents and twenty trained operating room nurses. Firstly, subjects applied force to the cricoid cartilage as was customary to them. Secondly, subjects used the device to guide the application of that force. Thirdly, subjects were again asked to perform the manoeuvre without visual guidance. Each test lasted 1 min and the amount of force applied was measured throughout. Overall, the Sellick maneuver was often not applied properly, with large variance between individual subjects. Performance and inter-subject consistency improved to a very highly significant degree when subjects were able to use the device as a visual guide (p < 0.001). Subsequent significant improvements in performances during the last, unguided test demonstrated that the device initiated learning. (paper)

  20. A new day for CME/CPD in Canada: proceedings from the 1st Canada Regional Conference of the Global Alliance for Medical Education in Montreal, Canada

    Directory of Open Access Journals (Sweden)

    Suzanne Murray

    2015-11-01

    Full Text Available The Global Alliance for Medical Education (GAME is a not-for-profit organization founded in 1995, with the aim of advancing innovation in medical education. The 1st GAME Canada regional conference was held in Montreal on May 22, 2015, under the leadership of Suzanne Murray, who acted as programme chair, and GAME president Lisa Sullivan. The conference brought together a broad array of speakers and panellists, including experts from academic centres, health systems, accreditors, private organizations, and industry. Thirty-one key stakeholders participated in the event, demonstrating a strong commitment towards the improvement of best practice in continuing medical education (CME/continuing professional development (CPD. The conference included diverse presentations providing opportunities for reflection and discussion throughout the day. The participants actively took part in stimulating discussions that covered a large range of topics, including the need for enhanced networking and opportunities to learn from others, the challenges of assessment and the potential solutions, interprofessional education and competencies, and, finally, the future of a Canadian CME/CPD organization.

  1. Interactive lectures: Clickers or personal devices? [v1; ref status: indexed, http://f1000r.es/54w

    OpenAIRE

    Lesley J. Morrell; Domino A. Joyce

    2015-01-01

    Audience response systems (?clickers?) are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost) can be overcome using students? personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using question...

  2. A study of inelastic electron-phonon interactions on tunneling magnetoresistance of a nano-scale device

    International Nuclear Information System (INIS)

    Modarresi, M.; Roknabadi, M.R.; Shahtahmasbi, N.; Vahedi Fakhrabad, D.; Arabshahi, H.

    2011-01-01

    In this research, we have studied the effect of inelastic electron-phonon interactions on current-voltage characteristic and tunneling magnetoresistance of a polythiophene molecule that is sandwiched between two cobalt electrodes using modified Green's function method as proposed by Walczak. The molecule is described with a modified Su-Schrieffer-Heeger Hamiltonian. The ground state of the molecule is obtained by Hellman-Feynman theorem. Electrodes are described in the wide-band approximation and spin-flip is neglected during conduction. Our calculation results show that with increase in voltage the currents increase and tunneling magnetoresistance decreases. Change in tunneling magnetoresistance due to inelastic interactions is limited in a small bias voltage interval and can be neglected in the other bias voltages. -- Research Highlights: →We investigate the effect of inelastic interaction on transport properties. →Due to inelastic interactions tunneling magnetoresistance decreases. →Decrease in TMR is restricted in a small voltage interval.

  3. Oligo- and polymeric FET devices: Thiophene-based active materials and their interaction with different gate dielectrics

    International Nuclear Information System (INIS)

    Porzio, W.; Destri, S.; Pasini, M.; Bolognesi, A.; Angiulli, A.; Di Gianvincenzo, P.; Natali, D.; Sampietro, M.; Caironi, M.; Fumagalli, L.; Ferrari, S.; Peron, E.; Perissinotti, F.

    2006-01-01

    Derivatives of both oligo- and polythiophene-based FET were recently considered for low cost electronic applications. In the device optimization, factors like redox reversibility of the molecule/polymer, electronic level compatibility with source/drain electrodes, packing closeness, and orientation versus the electrodes, can determine the overall performance. In addition, a gate insulator with a high dielectric constant, a low leakage current, and capability to promote ordering in the semiconductor is required to increase device performances and to lower the FET operating voltage. In this view, Al 2 O 3 appears a good candidate, although its widespread adoption is limited by the disorder that such oxide induces on the semiconductor with detrimental consequences on semiconductor electrical properties. In this contribution, an overview of recent results obtained on thiophene-derivative-based FET devices, fabricated by different growth techniques, and using both thermally grown SiO 2 and Al 2 O 3 from atomic layer deposition gate insulators will be reported and discussed with particular reference to organic solid state aggregation, morphology, and organic-inorganic interface

  4. Magnetic Fusion Energy Plasma Interactive and High Heat Flux Components: Volume 5, Technical assessment of critical issues in the steady state operation of fusion confinement devices

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    Critical issues for the steady state operation of plasma confinement devices exist in both the physics and technology fields of fusion research. Due to the wide range and number of these issues, this technical assessment has focused on the crucial issues associated with the plasma physics and the plasma interactive components. The document provides information on the problem areas that affect the design and operation of a steady state ETR or ITER type confinement device. It discusses both tokamaks and alternative concepts, and provides a survey of existing and planned confinement machines and laboratory facilities that can address the identified issues. A universal definition of steady state operation is difficult to obtain. From a physics point of view, steady state is generally achieved when the time derivatives approach zero and the operation time greatly exceeds the characteristic time constants of the device. Steady state operation for materials depends on whether thermal stress, creep, fatigue, radiation damage, or power removal are being discussed. For erosion issues, the fluence and availability of the machine for continuous operation are important, assuming that transient events such as disruptions do not limit the component lifetimes. The panel suggests, in general terms, that steady state requires plasma operation from 100 to 1000 seconds and an availability of more than a few percent, which is similar to the expectations for an ETR type device. The assessment of critical issues for steady state operation is divided into four sections: physics issues; technology issues; issues in alternative concepts; and devices and laboratory facilities that can address these problems.

  5. Magnetic Fusion Energy Plasma Interactive and High Heat Flux Components: Volume 5, Technical assessment of critical issues in the steady state operation of fusion confinement devices

    International Nuclear Information System (INIS)

    1988-01-01

    Critical issues for the steady state operation of plasma confinement devices exist in both the physics and technology fields of fusion research. Due to the wide range and number of these issues, this technical assessment has focused on the crucial issues associated with the plasma physics and the plasma interactive components. The document provides information on the problem areas that affect the design and operation of a steady state ETR or ITER type confinement device. It discusses both tokamaks and alternative concepts, and provides a survey of existing and planned confinement machines and laboratory facilities that can address the identified issues. A universal definition of steady state operation is difficult to obtain. From a physics point of view, steady state is generally achieved when the time derivatives approach zero and the operation time greatly exceeds the characteristic time constants of the device. Steady state operation for materials depends on whether thermal stress, creep, fatigue, radiation damage, or power removal are being discussed. For erosion issues, the fluence and availability of the machine for continuous operation are important, assuming that transient events such as disruptions do not limit the component lifetimes. The panel suggests, in general terms, that steady state requires plasma operation from 100 to 1000 seconds and an availability of more than a few percent, which is similar to the expectations for an ETR type device. The assessment of critical issues for steady state operation is divided into four sections: physics issues; technology issues; issues in alternative concepts; and devices and laboratory facilities that can address these problems

  6. Calibration of a measurement device as a result of efforts of interaction flow and turbo machines impeller; Calibracao de um dispositivo de medida de esforcos resultantes da interacao entre o escoamento e o rotor de turbomaquinas

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Jose Geraldo Trani; Tomazini, Jose Elias [UNESP, Guaratingueta, SP (Brazil). Faculdade de Engenharia. Dept. de Mecanica]. E-mails: brandao@feg.unesp.br; tomazini@feg.unesp.br

    2000-07-01

    This work reports the static calibration of a device used for measurements of the hydraulic efforts resulting from the interaction between the flow and the turbomachinery rotor, simulating the various operation conditions. The device was developed by the Stuttgart University. A calibration process is described for allowing a real correspondence among real efforts acting on the rotor model and the the measured efforts. The used device consists of load three dimension piezoelectric sensors.

  7. Proceedings of US/Japan Workshop (97FT5-06) on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices

    International Nuclear Information System (INIS)

    Nygren, Richard; Kureczko, Diana

    1998-10-01

    The 1997 US-Japan Workshop on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices was held at the Warwick Regis Hotel in San Francisco, California, on December 8-11, 1997. There were 53 presentations as well as discussions on technical issues and on planning for future collaborations, and 35 researchers from japan and the US participated in the workshop. Over the last few years, with the strong emphasis in the US on technology for ITER, there has been less work done in the US fusion program on basic plasma materials interaction and this change in emphasis workshops. The program this year emphasized activities that were not carried out under the ITER program and a new element this year in the US program was planning and some analysis on liquid surface concepts for advanced plasma facing components. The program included a ceremony to honor Professor Yamashina, who was retiring this year and a special presentation on his career

  8. Design and implementation of I2Vote--an interactive image-based voting system using windows mobile devices.

    Science.gov (United States)

    van Ooijen, P M A; Broekema, A; Oudkerk, M

    2011-08-01

    To develop, implement and test a novel audience response system (ARS) that allows image based interaction for radiology education. The ARS developed in this project is based on standard Personal Digital Assistants (PDAs) (HP iPAQ 114 classic handheld) running Microsoft® Windows Mobile® 6 Classic with a large 3.5 in. TFT touch screen (320×240 pixel resolution), high luminance and integrated IEEE 802.11b/g wireless. For software development Visual Studio 2008 professional (Microsoft) was used and all components were written in C#. Two test sessions were conducted to test the software technically followed by two real classroom tests in a radiology class for medical students on thoracic radiology. The novel ARS, called I2Vote, was successfully implemented and provided an easy to use, stable setup. The acceptance of both students and teachers was very high and the interaction with the students improved because of the anonymous interaction possibility. An easy to use handheld based ARS that enables interactive, image-based, teaching is achieved. The system effectively adds an extra dimension to the use of an ARS. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Design and implementation of I2Vote-An interactive image-based voting system using windows mobile devices

    NARCIS (Netherlands)

    van Ooijen, P. M. A.; Broekema, A.; Oudkerk, M.

    Purpose: To develop, implement and test a novel audience response system (ARS) that allows image based interaction for radiology education. Methods: The ARS developed in this project is based on standard Personal Digital Assistants (PDAs) (HP iPAQ 114 classic handheld) running Microsoft (R) Windows

  10. An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD

    Directory of Open Access Journals (Sweden)

    Jolanta Karpowicz

    2013-01-01

    Full Text Available Leakage of electromagnetic fields (EMF from short-wave radiofrequency physiotherapeutic diathermies (SWDs may cause health and safety hazards affecting unintentionally exposed workers (W or general public (GP members (assisting patient exposed during treatment or presenting there for other reasons. Increasing use of electronic active implantable medical devices (AIMDs, by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users. Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated. Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both—GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment.

  11. INTERACT

    DEFF Research Database (Denmark)

    Jochum, Elizabeth; Borggreen, Gunhild; Murphey, TD

    This paper considers the impact of visual art and performance on robotics and human-computer interaction and outlines a research project that combines puppetry and live performance with robotics. Kinesics—communication through movement—is the foundation of many theatre and performance traditions ...

  12. Exercise physiology with a left ventricular assist device: Analysis of heart-pump interaction with a computational simulator.

    Science.gov (United States)

    Fresiello, Libera; Rademakers, Frank; Claus, Piet; Ferrari, Gianfranco; Di Molfetta, Arianna; Meyns, Bart

    2017-01-01

    Patients with a Ventricular Assist Device (VAD) are hemodynamically stable but show an impaired exercise capacity. Aim of this work is to identify and to describe the limiting factors of exercise physiology with a VAD. We searched for data concerning exercise in heart failure condition and after VAD implantation from the literature. Data were analyzed by using a cardiorespiratory simulator that worked as a collector of inputs coming from different papers. As a preliminary step the simulator was used to reproduce the evolution of hemodynamics from rest to peak exercise (ergometer cycling) in heart failure condition. Results evidence an increase of cardiac output of +2.8 l/min and a heart rate increase to 67% of the expected value. Then, we simulated the effect of a continuous-flow VAD at both rest and exercise. Total cardiac output increases of +3.0 l/min (+0.9 l/min due to the VAD and +2.1 l/min to the native ventricle). Since the left ventricle works in a non-linear portion of the diastolic stiffness line, we observed a consistent increase of pulmonary capillary wedge pressure (from 14 to 20 mmHg) for a relatively small increase of end-diastolic volume (from 182 to 189 cm3). We finally increased VAD speed during exercise to the maximum possible value and we observed a reduction of wedge pressure (-4.5 mmHg), a slight improvement of cardiac output (8.0 l/min) and a complete unloading of the native ventricle. The VAD can assure a proper hemodynamics at rest, but provides an insufficient unloading of the left ventricle and does not prevent wedge pressure from rising during exercise. Neither the VAD provides major benefits during exercise in terms of total cardiac output, which increases to a similar extend to an unassisted heart failure condition. VAD speed modulation can contribute to better unload the ventricle but the maximal flow reachable with the current devices is below the cardiac output observed in a healthy heart.

  13. Theoretical aspects of the electronical devices operating due to interaction between annular electron beams and the azimuthal surface waves

    Energy Technology Data Exchange (ETDEWEB)

    Girka, V O; Girka, I O [Kharkiv State Univ. (Ukraine)

    1997-12-31

    The physical basis is discussed of electronic devices whose operation is based on the beam or dissipative instability of the azimuthal surface waves (ASW). The ASW are electromagnetic surface waves with extraordinary polarization (with field components E{sub r}, E{sub {phi}}, H{sub z}), propagating across the axial external steady magnetic field in the cylindrical metal waveguide with cold plasma filling. The ASW fields are described by Maxwell equations. To solve the problem, the authors used the Fourier method and numerical simulation of the equations obtained. The ASW excitation was examined under conditions of beam and dissipative instabilities due to the electron beam motion. The correction to ASW eigenfrequencies caused by the waveguide chamber noncircularity was also studied. ASW delaying leads to a negative frequency correction. The ASW energy can be emitted from the narrow slot in the metallic chamber of the waveguide. The optimum wavenumber range was found where the increment values are much greater than those of the ASW decrement caused by their energy radiation. (author). 2 figs., 3 refs.

  14. Ammonia formation and W coatings interaction with deuterium/nitrogen plasmas in the linear device GyM

    Energy Technology Data Exchange (ETDEWEB)

    Laguardia, L., E-mail: laguardia@ifp.cnr.it [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy); Caniello, R.; Cremona, A. [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy); Dellasega, D. [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy); Politecnico di Milano, Dipartimento di Energia, Milan (Italy); Dell’Era, F.; Ghezzi, F.; Gittini, G.; Granucci, G.; Mellera, V.; Minelli, D.; Pallotta, F. [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy); Passoni, M. [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy); Politecnico di Milano, Dipartimento di Energia, Milan (Italy); Ricci, D.; Vassallo, E. [CNR, Istituto di Fisica del Plasma“P. Caldirola”, Milan (Italy)

    2015-08-15

    In this work results of the first D{sub 2}/N{sub 2} experiments in GyM, a linear device able to produce plasmas of interest for the ITER divertor (n{sub e} 5 ⋅ 10{sup 10} cm{sup −3}, Te 5 eV, ion flux 3–5 ⋅ 10{sup 20} m{sup −2}s{sup −1}) are presented. Plasmas simulating a N-seeding scenario have been performed to evaluate ammonia formation and its effect on exposed W coatings. The presence of ND emission lines in the plasma can be correlated with the formation of ammonia, further directly detected and quantified by chromatography analysis of the exhaust. Four different W specimens were exposed in GyM to a plasma fluence of 8.78 ⋅ 10{sup 23} m{sup −2}. XPS analysis evidenced the formation of W{sub x}N{sub y} layers with nitrogen concentration in the range of 1–10% depending on the initial morphology and structure of the W samples. In all analyzed cases, nitrogen was bound and retained within the first 6 nm below the surface and no further diffusion of N into the bulk was observed.

  15. Computation of many-particle quantum trajectories with exchange interaction: application to the simulation of nanoelectronic devices

    International Nuclear Information System (INIS)

    Alarcón, A; Yaro, S; Cartoixà, X; Oriols, X

    2013-01-01

    Following Oriols (2007 Phys. Rev. Lett. 98 066803), an algorithm to deal with the exchange interaction in non-separable quantum systems is presented. The algorithm can be applied to fermions or bosons and, by construction, it exactly ensures that any observable is totally independent of the interchange of particles. It is based on the use of conditional Bohmian wave functions which are solutions of single-particle pseudo-Schrödinger equations. The exchange symmetry is directly defined by demanding symmetry properties of the quantum trajectories in the configuration space with a universal algorithm, rather than through a particular exchange–correlation functional introduced into the single-particle pseudo-Schrödinger equation. It requires the computation of N 2 conditional wave functions to deal with N identical particles. For separable Hamiltonians, the algorithm reduces to the standard Slater determinant for fermions (or permanent for bosons). A numerical test for a two-particle system, where exact solutions for non-separable Hamiltonians are computationally accessible, is presented. The numerical viability of the algorithm for quantum electron transport (in a far-from-equilibrium time-dependent open system) is demonstrated by computing the current and fluctuations in a nano-resistor, with exchange and Coulomb interactions among electrons. (paper)

  16. Voltage-controlled low-energy switching of nanomagnets through Ruderman-Kittel-Kasuya-Yosida interactions for magnetoelectric device applications

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Bahniman, E-mail: bghosh@utexas.edu; Dey, Rik; Register, Leonard F.; Banerjee, Sanjay K. [Microelectronics Research Center, University of Texas at Austin, 10100 Burnet Road, Bldg. 160, Austin, Texas 78758 (United States)

    2016-07-21

    In this article, we consider through simulation low-energy switching of nanomagnets via electrostatically gated inter-magnet Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions on the surface of three-dimensional topological insulators, for possible memory and nonvolatile logic applications. We model the possibility and dynamics of RKKY-based switching of one nanomagnet by coupling to one or more nanomagnets of set orientation. Potential applications to both memory and nonvolatile logic are illustrated. Sub-attojoule switching energies, far below conventional spin transfer torque (STT)-based memories and even below CMOS logic appear possible. Switching times on the order of a few nanoseconds, comparable to times for STT switching, are estimated for ferromagnetic nanomagnets, but the approach also appears compatible with the use of antiferromagnets which may allow for faster switching.

  17. Voltage-controlled low-energy switching of nanomagnets through Ruderman-Kittel-Kasuya-Yosida interactions for magnetoelectric device applications

    International Nuclear Information System (INIS)

    Ghosh, Bahniman; Dey, Rik; Register, Leonard F.; Banerjee, Sanjay K.

    2016-01-01

    In this article, we consider through simulation low-energy switching of nanomagnets via electrostatically gated inter-magnet Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions on the surface of three-dimensional topological insulators, for possible memory and nonvolatile logic applications. We model the possibility and dynamics of RKKY-based switching of one nanomagnet by coupling to one or more nanomagnets of set orientation. Potential applications to both memory and nonvolatile logic are illustrated. Sub-attojoule switching energies, far below conventional spin transfer torque (STT)-based memories and even below CMOS logic appear possible. Switching times on the order of a few nanoseconds, comparable to times for STT switching, are estimated for ferromagnetic nanomagnets, but the approach also appears compatible with the use of antiferromagnets which may allow for faster switching.

  18. Development of a novel device to trap heavy metal cations: application of the specific interaction between heavy metal cation and mismatch DNA base pair.

    Science.gov (United States)

    Torigoe, Hidetaka; Miyakawa, Yukako; Fukushi, Miyako; Ono, Akira; Kozasa, Tetsuo

    2009-01-01

    We have already found that Hg(II) cation specifically binds to T:T mismatch base pair in heteroduplex DNA, which increases the melting temperature of heteroduplex DNA involving T:T mismatch base pair by about 4 degrees C. We have also found that Ag(I) cation specifically binds to C:C mismatch base pair in heteroduplex DNA, which increases the melting temperature of heteroduplex DNA involving C:C mismatch base pair by about 4 degrees C. Using the specific interaction, we developed a novel device to trap each of Hg(II) and Ag(I) cation. The device is composed of 5'-biotinylated T-rich or C-rich DNA oligonucleotides, BIO-T20: 5'-Bio-T(20)-3' or BIO-C20: 5'-Bio-C(20)-3' (Bio is a biotin), immobilized on streptavidin-coated polystylene beads. When the BIO-T20-immobilized beads were added to a solution containing Hg(II) cation, and the beads trapping Hg(II) cation were collected by centrifugation, almost all of Hg(II) cation were removed from the solution. Also, when the BIO-C20-immobilized beads were added to a solution containing Ag(I) cation, and the beads trapping Ag(I) cation were collected by centrifugation, almost all of Ag(I) cation were removed from the solution. We conclude that, using the novel device developed in this study, Hg(II) and Ag(I) cation can be effectively removed from the solution.

  19. A comparative study: use of a Brain-computer Interface (BCI) device by people with cerebral palsy in interaction with computers.

    Science.gov (United States)

    Heidrich, Regina O; Jensen, Emely; Rebelo, Francisco; Oliveira, Tiago

    2015-01-01

    This article presents a comparative study among people with cerebral palsy and healthy controls, of various ages, using a Brain-computer Interface (BCI) device. The research is qualitative in its approach. Researchers worked with Observational Case Studies. People with cerebral palsy and healthy controls were evaluated in Portugal and in Brazil. The study aimed to develop a study for product evaluation in order to perceive whether people with cerebral palsy could interact with the computer and compare whether their performance is similar to that of healthy controls when using the Brain-computer Interface. Ultimately, it was found that there are no significant differences between people with cerebral palsy in the two countries, as well as between populations without cerebral palsy (healthy controls).

  20. Coatings of Different Carbon Nanotubes on Platinum Electrodes for Neuronal Devices: Preparation, Cytocompatibility and Interaction with Spiral Ganglion Cells.

    Science.gov (United States)

    Burblies, Niklas; Schulze, Jennifer; Schwarz, Hans-Christoph; Kranz, Katharina; Motz, Damian; Vogt, Carla; Lenarz, Thomas; Warnecke, Athanasia; Behrens, Peter

    2016-01-01

    Cochlear and deep brain implants are prominent examples for neuronal prostheses with clinical relevance. Current research focuses on the improvement of the long-term functionality and the size reduction of neural interface electrodes. A promising approach is the application of carbon nanotubes (CNTs), either as pure electrodes but especially as coating material for electrodes. The interaction of CNTs with neuronal cells has shown promising results in various studies, but these appear to depend on the specific type of neurons as well as on the kind of nanotubes. To evaluate a potential application of carbon nanotube coatings for cochlear electrodes, it is necessary to investigate the cytocompatibility of carbon nanotube coatings on platinum for the specific type of neuron in the inner ear, namely spiral ganglion neurons. In this study we have combined the chemical processing of as-delivered CNTs, the fabrication of coatings on platinum, and the characterization of the electrical properties of the coatings as well as a general cytocompatibility testing and the first cell culture investigations of CNTs with spiral ganglion neurons. By applying a modification process to three different as-received CNTs via a reflux treatment with nitric acid, long-term stable aqueous CNT dispersions free of dispersing agents were obtained. These were used to coat platinum substrates by an automated spray-coating process. These coatings enhance the electrical properties of platinum electrodes, decreasing the impedance values and raising the capacitances. Cell culture investigations of the different CNT coatings on platinum with NIH3T3 fibroblasts attest an overall good cytocompatibility of these coatings. For spiral ganglion neurons, this can also be observed but a desired positive effect of the CNTs on the neurons is absent. Furthermore, we found that the well-established DAPI staining assay does not function on the coatings prepared from single-wall nanotubes.

  1. Providers with Limited Experience Perform Better in Advanced Life Support with Assistance Using an Interactive Device with an Automated External Defibrillator Linked to a Ventilator.

    Science.gov (United States)

    Busch, Christian Werner; Qalanawi, Mohammed; Kersten, Jan Felix; Kalwa, Tobias Johannes; Scotti, Norman Alexander; Reip, Wikhart; Doehn, Christoph; Maisch, Stefan; Nitzschke, Rainer

    2015-10-01

    Medical teams with limited experience in performing advanced life support (ALS) or with a low frequency of cardiopulmonary resuscitation (CPR) while on duty, often have difficulty complying with CPR guidelines. This study evaluated whether the quality of CPR of trained medical students, who served as an example of teams with limited experience in ALS, could be improved with device assistance. The primary outcome was the hands-off time (i.e., the percentage of the entire CPR time without chest compressions). The secondary outcome was seven time intervals, which should be as short as possible, and the quality of ventilations and chest compressions on the mannequin. We compared standard CPR equipment to an interactive device with visual and acoustic instructions for ALS workflow measures to guide briefly trained medical students through the ALS algorithm in a full-scale mannequin simulation study with a randomized crossover study design. The study equipment consisted of an automatic external defibrillator and ventilator that were electronically linked and communicating as a single system. Included were regular medical students in the third to sixth years of medical school of one class who provided written informed consent for voluntary participation and for the analysis of their CPR performance data. No exclusion criteria were applied. For statistical measures of evaluation we used an analysis of variance for crossover trials accounting for treatment effect, sequence effect, and carry-over effect, with adjustment for prior practical experience of the participants. Forty-two medical students participated in 21 CPR sessions, each using the standard and study equipment. Regarding the primary end point, the study equipment reduced the hands-off time from 40.1% (95% confidence interval [CI] 36.9-43.4%) to 35.6% (95% CI 32.4-38.9%, p = 0.031) compared with the standard equipment. Within the prespecified secondary end points, study equipment reduced the time interval until

  2. Investigation of plasma interaction with carbon based and mixed materials related to next-generation fusion devices

    International Nuclear Information System (INIS)

    Guseva, M.I.; Martynenko, Yu.V.; Korshunov, S.N.

    2003-01-01

    Carbon-carbon composites, tungsten and beryllium are considered at present as candidate-materials for International Thermonuclear Experimental Reactor (ITER). The presence of various materials, as the divertor and the first wall components, will unavoidably result in the formation of mixed layers on the surfaces of plasma facing components. In this review, processes of plasma interaction with these materials and layers formed by mixing of the materials are considered. Mixed W-Be and W-C layers were prepared by deposition of two species atoms upon a substrate under simultaneous sputtering of two targets by 20 keV Ar + -ions. The thickness of the deposited mixed layers was 100-500 nm. The most important processes investigated here are: a) erosion at threshold energies and at various temperatures, b) erosion at plasma disruption, c) surface modification at normal operation regime and disruption, d) the influence of the surface modification on material erosion, e) erosion product formation at plasma disruption (dust creation), f) hydrogen isotopes retention in materials. An experimental method of determination of sputtering yield under ion bombardment in the near-threshold energy range has been developed. The method is based on the use of special regimes of field ion microscopic analysis. The method has been used for measurement of the sputtering yield of C-C composite, technically pure tungsten, tungsten oxide and mixed W-C layer on the tungsten by deuterium ions. The energy dependences of the sputtering yield of those materials by deuterium ions at energies ranging from 10 to 500 eV was investigated. Temperature dependences of pure and B-doped C-C composites erosion by deuterium ions were investigated. Material erosion was studied in a steady state plasma at the LENTA facility with parameters close to those expected at normal operation of ITER, and in the MKT plasma accelerator simulating plasma disruption. Surface modifications of graphite materials and tungsten

  3. The Effectiveness of Interacting with Scientific Animations in Chemistry Using Mobile Devices on Grade 12 Students' Spatial Ability and Scientific Reasoning Skills

    Science.gov (United States)

    Al-Balushi, Sulaiman M.; Al-Musawi, Ali S.; Ambusaidi, Abdullah K.; Al-Hajri, Fatemah H.

    2017-02-01

    The purpose of the current study was to investigate the effectiveness of interacting with animations using mobile devices on grade 12 students' spatial and reasoning abilities. The study took place in a grade 12 context in Oman. A quasi-experimental design was used with an experimental group of 32 students and a control group of 28 students. The experimental group studied chemistry using mobile tablets that had a digital instructional package with different animation and simulations. There was one tablet per student. A spatial ability test and a scientific reasoning test were administered to both groups prior and after the study, which lasted for 9 weeks. The findings showed that there were significant statistical differences between the two groups in terms of spatial ability in favour of the experimental group. However, there were no differences between the two groups in terms of reasoning ability. The authors reasoned that the types of animations and simulations used in the current study featured a wide range of three-dimensional animated illustrations at the particulate level of matter. Most probably, this decreased the level of abstractness that usually accompanies chemical entities and phenomena and helped the students to visualize the interactions between submicroscopic entities spatially. Further research is needed to decide on types of scientific animations that could help students improve their scientific reasoning.

  4. Association of medical students' reports of interactions with the pharmaceutical and medical device industries and medical school policies and characteristics: a cross-sectional study.

    Science.gov (United States)

    Yeh, James S; Austad, Kirsten E; Franklin, Jessica M; Chimonas, Susan; Campbell, Eric G; Avorn, Jerry; Kesselheim, Aaron S

    2014-10-01

    Professional societies use metrics to evaluate medical schools' policies regarding interactions of students and faculty with the pharmaceutical and medical device industries. We compared these metrics and determined which US medical schools' industry interaction policies were associated with student behaviors. Using survey responses from a national sample of 1,610 US medical students, we compared their reported industry interactions with their schools' American Medical Student Association (AMSA) PharmFree Scorecard and average Institute on Medicine as a Profession (IMAP) Conflicts of Interest Policy Database score. We used hierarchical logistic regression models to determine the association between policies and students' gift acceptance, interactions with marketing representatives, and perceived adequacy of faculty-industry separation. We adjusted for year in training, medical school size, and level of US National Institutes of Health (NIH) funding. We used LASSO regression models to identify specific policies associated with the outcomes. We found that IMAP and AMSA scores had similar median values (1.75 [interquartile range 1.50-2.00] versus 1.77 [1.50-2.18], adjusted to compare scores on the same scale). Scores on AMSA and IMAP shared policy dimensions were not closely correlated (gift policies, r = 0.28, 95% CI 0.11-0.44; marketing representative access policies, r = 0.51, 95% CI 0.36-0.63). Students from schools with the most stringent industry interaction policies were less likely to report receiving gifts (AMSA score, odds ratio [OR]: 0.37, 95% CI 0.19-0.72; IMAP score, OR 0.45, 95% CI 0.19-1.04) and less likely to interact with marketing representatives (AMSA score, OR 0.33, 95% CI 0.15-0.69; IMAP score, OR 0.37, 95% CI 0.14-0.95) than students from schools with the lowest ranked policy scores. The association became nonsignificant when fully adjusted for NIH funding level, whereas adjusting for year of education, size of school, and publicly versus

  5. Association of medical students' reports of interactions with the pharmaceutical and medical device industries and medical school policies and characteristics: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    James S Yeh

    2014-10-01

    Full Text Available Professional societies use metrics to evaluate medical schools' policies regarding interactions of students and faculty with the pharmaceutical and medical device industries. We compared these metrics and determined which US medical schools' industry interaction policies were associated with student behaviors.Using survey responses from a national sample of 1,610 US medical students, we compared their reported industry interactions with their schools' American Medical Student Association (AMSA PharmFree Scorecard and average Institute on Medicine as a Profession (IMAP Conflicts of Interest Policy Database score. We used hierarchical logistic regression models to determine the association between policies and students' gift acceptance, interactions with marketing representatives, and perceived adequacy of faculty-industry separation. We adjusted for year in training, medical school size, and level of US National Institutes of Health (NIH funding. We used LASSO regression models to identify specific policies associated with the outcomes. We found that IMAP and AMSA scores had similar median values (1.75 [interquartile range 1.50-2.00] versus 1.77 [1.50-2.18], adjusted to compare scores on the same scale. Scores on AMSA and IMAP shared policy dimensions were not closely correlated (gift policies, r = 0.28, 95% CI 0.11-0.44; marketing representative access policies, r = 0.51, 95% CI 0.36-0.63. Students from schools with the most stringent industry interaction policies were less likely to report receiving gifts (AMSA score, odds ratio [OR]: 0.37, 95% CI 0.19-0.72; IMAP score, OR 0.45, 95% CI 0.19-1.04 and less likely to interact with marketing representatives (AMSA score, OR 0.33, 95% CI 0.15-0.69; IMAP score, OR 0.37, 95% CI 0.14-0.95 than students from schools with the lowest ranked policy scores. The association became nonsignificant when fully adjusted for NIH funding level, whereas adjusting for year of education, size of school, and publicly

  6. The Nuclear Engineering Doctorate and NTEC CPD and Masters programmes: education, training and research for the decommissioning skills-base - 16395

    International Nuclear Information System (INIS)

    Roberts, John W.

    2009-01-01

    Since its establishment in 2005 the Nuclear Decommissioning Authority (NDA) has a remit to maintain the skills-base for safe, secure and cost effective decommissioning of the existing UK civil nuclear power plants and associated facilities. With an aging workforce and a competitive tender process for each project a number of new companies are realising the potential of the UK decommissioning market. The Nuclear Engineering Doctorate and NTEC Masters Programmes have been designed to provide the nuclear workforce of the future. The doctorate is a partnership between industry, a university partner and the research engineer with the benefit to industry that the research engineer is based with the industrial partner. Technical and management modules are studied at the university whilst the research project is carried out in the industrial environment. The Masters programme draws on the expertise of 11 Higher Education Institutes and offers over 20 modules that are delivered in a short-fat format either as standalone CPD courses or, by taking further modules, a certificate, diploma or on completion of a research project an M.Sc. Modules are available that cover the technical aspects of decommissioning as well as management of the decommissioning process. The availability of modules in a Distance Learning format now enables students based around the world to benefit from this programme. This paper will describe the two programmes in detail and provide examples of current projects that are delivering the research and workforce required for a successful decommissioning programme. (author)

  7. Effectiveness of distance learning strategies for continuing professional development (CPD) for rural allied health practitioners: a systematic review.

    Science.gov (United States)

    Berndt, Angela; Murray, Carolyn M; Kennedy, Kate; Stanley, Mandy J; Gilbert-Hunt, Susan

    2017-07-12

    Allied health professionals working in rural areas face unique challenges, often with limited access to resources. Accessing continuing professional development is one of those challenges and is related to retention of workforce. Effectiveness of distance learning strategies for continuing professional development in rural allied healthcare workers has not been evaluated. We searched 17 databases and the grey literature up to September 2016 following the PRISMA guidelines. Any primary studies were included that focussed on allied health and distance delivery regardless of education topic or study design. Two independent reviewers extracted data and critically appraised the selected studies. The search returned 5257 results. With removal of duplicate references, we reviewed 3964 article titles and abstracts; n = 206 appeared potentially eligible and were scrutinised via full text screening; n = 14 were included. Studies were published between 1997 and 2016, were of varied methodological quality and were predominantly from Australia, USA and Canada with a focus on satisfaction of learners with the delivery method or on measures of educational outcomes. Technologies used to deliver distance education included video conference, teleconference, web based platforms and virtual reality. Early papers tended to focus more on the technology characteristics than educational outcomes. Some studies compared technology based delivery to face to face modes and found satisfaction and learning outcomes to be on par. Only three studies reported on practice change following the educational intervention and, despite a suggestion there is a link between the constructs, none measured the relationship between access to continuing professional development and workforce retention. Technology based options of delivery have a high utility, however the complex inter-relatedness of time, use, travel, location, costs, interactivity, learning outcomes and educational design suggest a need

  8. Study of two-step mechanisms in the 12C(p,d)11C reaction at 45 MeV

    International Nuclear Information System (INIS)

    Couvert, Pierre.

    1974-01-01

    An attempt was made to find the nuclear reaction mechanisms explaining the intensity and behavior of the cross sections in the 12 C(p,d) 11 C reaction at 45 MeV. First, the conventional interpretation of the experimental data leads to two closely related conclusions. The behavior of the cross-sections measured cannot be explained without including the intermediate stage of collective 2 + 12 C excitation or accounting for its possible interference with the direct capture of a neutron. The relative intensity of the different mechanisms is directly bound up with the value of the nuclear structure parameters of the wave function adopted. As a result this study is found to be an excellent wave function test and the results obtained seem to prove that the wave function calculated by Clegg for 11 B is also suitable for 11 C. Next a two-stage process was introduced, using inelastic deuteron scattering on 11 C as the intermediate stage. The problem which then arises is to determine the deformation parameters of the final nucleus in its different excitation states. The model adopted is in fact very crude and only gives quantitative information on the physical reality of such a process. Some improvement is shown to be obtained by finite range and non-local potential corrections. It is observed that track-transitions, which correspond in fact to new processes interfering with those already introduced play an important part. The most realistic way to treat the problem is thus to make an exact calculation within the coupled equation system, keeping strictly to physically justified hypotheses [fr

  9. Modelling of plasma-antenna coupling and non-linear radio frequency wave-plasma-wall interactions in the magnetized plasma device under ion cyclotron range of frequencies

    International Nuclear Information System (INIS)

    Lu, LingFeng

    2016-01-01

    Ion Cyclotron Resonant Heating (ICRH) by waves in 30-80 MHz range is currently used in magnetic fusion plasmas. Excited by phased arrays of current straps at the plasma periphery, these waves exist under two polarizations. The Fast Wave tunnels through the tenuous plasma edge and propagates to its center where it is absorbed. The parasitically emitted Slow Wave only exists close to the launchers. How much power can be coupled to the center with 1 A current on the straps? How do the emitted radiofrequency (RF) near and far fields interact parasitically with the edge plasma via RF sheath rectification at plasma-wall interfaces? To address these two issues simultaneously, in realistic geometry over the size of ICRH antennas, this thesis upgraded and tested the Self-consistent Sheaths and Waves for ICH (SSWICH) code. SSWICH couples self-consistently RF wave propagation and Direct Current (DC) plasma biasing via non-linear RF and DC sheath boundary conditions (SBCs) at plasma/wall interfaces. Its upgrade is full wave and was implemented in two dimensions (toroidal/radial). New SBCs coupling the two polarizations were derived and implemented along shaped walls tilted with respect to the confinement magnetic field. Using this new tool in the absence of SBCs, we studied the impact of a density decaying continuously inside the antenna box and across the Lower Hybrid (LH) resonance. Up to the memory limits of our workstation, the RF fields below the LH resonance changed with the grid size. However the coupled power spectrum hardly evolved and was only weakly affected by the density inside the box. In presence of SBCs, SSWICH-FW simulations have identified the role of the fast wave on RF sheath excitation and reproduced some key experimental observations. SSWICH-FW was finally adapted to conduct the first electromagnetic and RF-sheath 2D simulations of the cylindrical magnetized plasma device ALINE. (author) [fr

  10. Grasp interaction with tablets

    CERN Document Server

    Wolf, Katrin

    2015-01-01

    This book presents guidelines for a future device type: a tablet that allows ergonomic front- and back-of-device interaction. These guidelines help designers and developers of user interfaces to build ergonomic applications for tablet devices, in particular for devices that enable back-of-device interaction. In addition, manufacturers of tablet devices obtain arguments that back-of-device interaction is a promising extension of the interaction design space and results in increased input capabilities, enriched design possibilities, and proven usability. The guidelines are derived from empirical studies and developed to fit the users’ skills to the way the novel device type is held. Three particular research areas that are relevant to develop design guidelines for tablet interaction are investigated: ergonomic gestures, interaction areas, and pointing techniques.

  11. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  12. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  13. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  14. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    Health Canada recommends that hospitals should have procedures in place to ensure Reusable Medical Devices (RMD) are cleaned, disinfected and sterilized according to the manufacturer's instructions. For the purpose of this paper, reusable medical devices will be referred to as RMDs and include all instrumentation and devices that the Central Processing Department (CPD) resterilizes for use in the hospital. Patient safety in surgery begins in CPD. Manufacturer recommendations for the decontamination and sterilization of surgical instrumentation are of utmost importance to Operating Room (OR) and CPD staff. With recommendations that are unclear, nonspecific or unattainable there was a need to define what it means institutionally to meet standards and provide safe patient care while continuing to support the advancement of surgical technology. The purpose of this paper is to describe the challenges faced by one multisite organization (The University Health Network) in managing the sterilization of surgical instrumentation. The development of The Guidance Matrix by the network's inter-professional Reusable Medical Device (RMD) Committee, will be discussed along with information about the elements of this tool and an illustration of how it is used. The key benefits of The Guidance Matrix, including how its use has facilitated transparent decision-making, communication and collaboration regarding sterilization issues across the sites, will be described. Sterilization processes in Central Processing Departments (CPD) include chemical indicators, dated load indicators, and tamperproof locks and filters. The lack of an indicator of sterilization can be a frustrating experience for an OR Nurse. But do we really understand the critical importance of all these indicators? The foundation of sterilizing reusable medical devices (RMDs) begins with proper processes, standards and subsequent scientific validation from the vendors. According to AORN, patient safety is vital and it

  15. Proceedings of Japan-U.S. workshop P-196 on high heat flux components and plasma surface interactions for next devices

    International Nuclear Information System (INIS)

    Wilson, K.N.; Yamashina, T.

    1993-03-01

    The Japan-US Workshop P-196 was successfully carried out in Kyushu University, Chikushi Campus, from November 17 to 19. The major concern was on the research and development required both for international Thermonuclear Experimental Reactor (ITER) and Large Helical Device (LHD). Most of the discussion items was similar to that of the last workshop, e.g. PFC and PSI in Large Device, High Heat Flux Component, Laboratory Studies and Neutron Damage. The presentation number concerning High Heat Flux Component was largest. (J.P.N.)

  16. How 'blended' is blended learning?: students' perceptions of issues around the integration of online and face-to-face learning in a Continuing Professional Development (CPD) health care context.

    Science.gov (United States)

    Glogowska, Margaret; Young, Pat; Lockyer, Lesley; Moule, Pam

    2011-11-01

    This paper explores students' perceptions of blended learning modules delivered in a Continuing Professional Development (CPD) health care context in the UK. 'Blended learning' is the term used to describe a hybrid model of learning where traditional face-to-face teaching approaches and newer electronic learning activities and resources are utilised together. A new model of CPD for health care practitioners based on a blended learning approach was developed at a university in the south west of England. As part of the evaluation of the new modules, a qualitative study was conducted, in which 17 students who had experienced the modules were interviewed by telephone. Three main themes emerged from the interviews relating to the 'blended' nature of the blended learning modules. These were i) issues around the opportunities for discussion of online materials face-to-face; ii) issues of what material should be online versus face-to-face and iii) balancing online and face-to-face components. Teaching staff engaged in the development of blended learning courses need to pay particular attention to the ways in which they develop and integrate online and face-to-face materials. More attention needs to be paid to allowing opportunity for students to come together to create a 'community of inquiry'. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  18. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  19. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  20. Fabrication of type I collagen microcarrier using a microfluidic 3D T-junction device and its application for the quantitative analysis of cell-ECM interactions.

    Science.gov (United States)

    Yoon, Junghyo; Kim, Jaehoon; Jeong, Hyo Eun; Sudo, Ryo; Park, Myung-Jin; Chung, Seok

    2016-08-26

    We presented a new quantitative analysis for cell and extracellular matrix (ECM) interactions, using cell-coated ECM hydrogel microbeads (hydrobeads) made of type I collagen. The hydrobeads can carry cells as three-dimensional spheroidal forms with an ECM inside, facilitating a direct interaction between the cells and ECM. The cells on hydrobeads do not have a hypoxic core, which opens the possibility for using as a cell microcarrier for bottom-up tissue reconstitution. This technique can utilize various types of cells, even MDA-MB-231 cells, which have weak cell-cell interactions and do not form spheroids in conventional spheroid culture methods. Morphological indices of the cell-coated hydrobead visually present cell-ECM interactions in a quantitative manner.

  1. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  2. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  3. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  4. Wireless device connection problems and design solutions

    Science.gov (United States)

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  5. Effect of an interactive cardiopulmonary resuscitation assist device with an automated external defibrillator synchronised with a ventilator on the CPR performance of emergency medical service staff: a randomised simulation study.

    Science.gov (United States)

    Nitzschke, Rainer; Doehn, Christoph; Kersten, Jan F; Blanz, Julian; Kalwa, Tobias J; Scotti, Norman A; Kubitz, Jens C

    2017-04-04

    The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the

  6. Experience of three-dimensional vision in the era of digital interaction new devices : opportunity and challenges for applied mathematics and visual design

    CERN Document Server

    Brunetti, Federico Alberto

    2014-01-01

    It will be soon presented to the public a new version of stereoscopic viewers designed for observing files and video projected images through a system of transparent optical prisms which allow the simultaneous perception of the surrounding environment. The real challenge for applied mathematics and visual design will be to prefigure how to use them and their applications, since these new devices can actually enable a deeper visual experience. A specific case study concerns the visualizations of the collisions at the LHC at CERN, selected to verify the traces of the boson theorized by Francois Englert and Peter Higgs, with Robert Brout, who recently (2013) received the Nobel Prize for their research.

  7. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  8. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  9. News Workshop: Getting the measure of space Conference: Respecting the evidence receives a great response Event: Communities meet to stimulate science in Wales Teachers: A day to polish up on A-level practicals Development: Exhilarating physics CPD day is a hit in London Lecture: The universe as a classroom

    Science.gov (United States)

    2013-07-01

    Workshop: Getting the measure of space Conference: Respecting the evidence receives a great response Event: Communities meet to stimulate science in Wales Teachers: A day to polish up on A-level practicals Development: Exhilarating physics CPD day is a hit in London Lecture: The universe as a classroom

  10. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  11. Dielectrokinetic chromatography devices

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-12-16

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  12. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  13. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  14. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  15. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  16. Fluctuations in quantum devices

    Directory of Open Access Journals (Sweden)

    H.Haken

    2004-01-01

    Full Text Available Logical gates can be formalized by Boolean algebra whose elementary operations can be realized by devices that employ the interactions of macroscopic numbers of elementary excitations such as electrons, holes, photons etc. With increasing miniaturization to the nano scale and below, quantum fluctuations become important and can no longer be ignored. Based on Heisenberg equations of motion for the creation and annihilation operators of elementary excitations, I determine the noise sources of composite quantum systems.

  17. Biomolecular detection device

    Science.gov (United States)

    Huo, Qisheng [Albuquerque, NM; Liu, Jun [Albuquerque, NM

    2008-10-21

    A device for detecting and measuring the concentration of biomolecules in solution, utilizing a conducting electrode in contact with a solution containing target biomolecules, with a film with controllable pore size distribution characteristics applied to at least one surface of the conducting electrode. The film is functionalized with probe molecules that chemically interact with the target biomolecules at the film surface, blocking indicator molecules present in solution from diffusing from the solution to the electrode, thereby changing the electrochemical response of the electrode.

  18. Assistive device with conventional, alternative, and brain-computer interface inputs to enhance interaction with the environment for people with amyotrophic lateral sclerosis: a feasibility and usability study.

    Science.gov (United States)

    Schettini, Francesca; Riccio, Angela; Simione, Luca; Liberati, Giulia; Caruso, Mario; Frasca, Vittorio; Calabrese, Barbara; Mecella, Massimo; Pizzimenti, Alessia; Inghilleri, Maurizio; Mattia, Donatella; Cincotti, Febo

    2015-03-01

    To evaluate the feasibility and usability of an assistive technology (AT) prototype designed to be operated with conventional/alternative input channels and a P300-based brain-computer interface (BCI) in order to provide users who have different degrees of muscular impairment resulting from amyotrophic lateral sclerosis (ALS) with communication and environmental control applications. Proof-of-principle study with a convenience sample. An apartment-like space designed to be fully accessible by people with motor disabilities for occupational therapy, placed in a neurologic rehabilitation hospital. End-users with ALS (N=8; 5 men, 3 women; mean age ± SD, 60 ± 12 y) recruited by a clinical team from an ALS center. Three experimental conditions based on (1) a widely validated P300-based BCI alone; (2) the AT prototype operated by a conventional/alternative input device tailored to the specific end-user's residual motor abilities; and (3) the AT prototype accessed by a P300-based BCI. These 3 conditions were presented to all participants in 3 different sessions. System usability was evaluated in terms of effectiveness (accuracy), efficiency (written symbol rate, time for correct selection, workload), and end-user satisfaction (overall satisfaction) domains. A comparison of the data collected in the 3 conditions was performed. Effectiveness and end-user satisfaction did not significantly differ among the 3 experimental conditions. Condition III was less efficient than condition II as expressed by the longer time for correct selection. A BCI can be used as an input channel to access an AT by persons with ALS, with no significant reduction of usability. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Assistive technologies for the interaction of the elderly the development of a communication device for the elderly with complementing illustrations and examples

    CERN Document Server

    2014-01-01

    This book presents a wealth of insights and new conceptualizations for the development of Assistive Technologies for the Interaction of the Elderly. The book arranges the chapters according to important aspects of maximizing the use value in innovation projects. Every chapter will include an executive summary reporting the main results, a storyline using everyday language, and scientific excursions, wherever useful. The book shows how an innovation project should be structured towards maximum use value and how a project should be structured in order to make a difference. It describes the useful categorization of the large group of the elderly to maximize the focus of the innovation and demonstrates the user involvement into innovation activities. Of course, the assessment of such innovative projects is discussed as well as the “lessons learned”. The book also explores the business opportunities and the financial evaluation of aspects of assistive technology.  

  20. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  1. Designing for mobile interaction

    DEFF Research Database (Denmark)

    Nazzi, Elena

    2009-01-01

    The theme of this PhD project is designing for mobile interaction with devices and services, for the accessing, making, and sharing of information, taking into account the dynamic physical and social settings that embrace this interaction. To narrow down this theme, the whole project focuses...... on the exploitation of social interaction --- in particular among senior citizens --- to enhance and support mobile interaction....

  2. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  3. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  4. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  5. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  6. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  7. Collocated Interaction

    DEFF Research Database (Denmark)

    E. Fischer, Joel; Porcheron, Martin; Lucero, Andrés

    2016-01-01

    interactions. Yet, new challenges abound as people wear and carry more devices than ever, creating fragmented device ecologies at work, and changing the ways we socialise with each other. In this workshop we seek to start a dialogue to look back as well as forward, review best practices, discuss and design......In the 25 years since Ellis, Gibbs, and Rein proposed the time-space taxonomy, research in the ‘same time, same place’ quadrant has diversified, perhaps even fragmented. This one-day workshop will bring together researchers with diverse, yet convergent interests in tabletop, surface, mobile...

  8. User Experience of Mobile Devices

    DEFF Research Database (Denmark)

    Raptis, Dimitrios

    that the overall physical form of a mobile device has a significant effect on the perceived usability of an application: the more attractive the physical form, the higher the perceived usability. The other study validated the effect of a particular physical form element on usability and showed that the screen size......This thesis focuses on mobile devices and it specifically investigates the effect of their physical form on two perceived user experience qualities, usability and coolness. With the term mobile devices, I refer to interactive products that users interact with while being on the move......, and with the term physical form I refer to the physical elements that constitute a mobile device as a whole, such as weight, size and materials. The selected research area was addressed through two research questions, one focusing on effects of physical form on usability and the other on effects on coolness...

  9. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  10. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  11. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  12. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  13. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  14. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  15. Thermonuclear device

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Yamamoto, Masahiro; Furuyama, Masayuki; Saito, Ryusei.

    1981-01-01

    Purpose: To enable the efficient and rapid cooling of a vacuum vessel by cooling with gas when the temperature of the vacuum vessel is higher than the boiling point of water and cooling with water when the temperature is lower than the boiling point of water. Constitution: A cooling pipe is provided through an insulating pipe on the outer periphery of a vacuum vessel. The cooling pipe communicates through a cooling gas valve and a coolant valve with a cooling gas supply device and a coolant supply device, and a heat exchanger is disposed at the pipe. When the vessel is higher than the boiling point of the coolant the coolant valve is closed and the cooling gas valve is opened and gas is supplied to cool the vessel. The gas is recoverd through a heat exchanger. On the other hand, when the temperature of vessel is lower than the boiling point of the coolant, the gas valve is closed, the coolant valve is opened, and the vessel is cooled with coolant. The vacuum vessel can be cooled for short time employing both the gas and the coolant together. (Yoshino, Y.)

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  17. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  18. Thermonuclear device

    International Nuclear Information System (INIS)

    Furuyama, Masayuki.

    1979-01-01

    Purpose: To provide the subject device wherein a conductive short-circuiting ring is installed in the vicinity of the bonded part of bellows and thick portion of vacuum vessel in the small circumferential direction of torus, thereby to reduce the electromagnetic force generated at the bellows. Constitution: A conductive short-circuiting ring is provided in the vicinity of the connected part of a thick portion and bellows portion. By this organization, a saddle type current generated at the thick portion by a vertical magnetic field flows through the short-circuiting ring because the resistance at a part where the short-circuiting ring is provided is reduced, and the current flowing through the bellows is remarkably reduced. For this reason, the electromagnetic force generated at the bellows is reduced thereby to prevent the bellows from being destroyed by the electromagnetic force. (Yoshihara, H.)

  19. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  20. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei

    1988-01-01

    Purpose: To obtain high voltage withstanding current introduction terminals not suffering from the effects of the reduction in the creeping voltage withstanding property by the application of magnetic fields. Constitution: This invention concerns a current introduction terminal for supplying electric current to coils for use in a thermonuclear device, etc. The conductor of the current introduction terminal on the side of vacuum is completely covered with solid insulator. This can eliminate the portion of securing the creeping withstanding voltage. The voltage withstanding characteristics of the solid insulator covering the portion of the conductor on the side of vacuum has a constant value irrespective of the atmosphere or the absence or presence of magnetic fields. Accordingly, the voltage withstanding characteristics of the current introduction terminal on the side of vacuum are determined by the property of the solid insulator, which is not reduced by the application of magnetic fields. (Ikeda, J.)

  1. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  2. Interacting with a personal wearable device

    NARCIS (Netherlands)

    Haan, de G.; Wright, P.; Hollnagel, E.; Dekker, S.

    2000-01-01

    Comris is a research project that aims to create a wearable assistant, "the parrot", for conference and workshop visitors. A personal interest profile and an active badge system enable agents in a virtual information space to provide context-sensitive information about interesting persons and events

  3. Optical-Microwave Interactions in Semiconductor Devices.

    Science.gov (United States)

    1981-03-01

    Interdigital Photoconductors ( IDPC ) ......... ..... 112 G. Conclusions.. ....... .. 120 6 CONCLUSIONS AND RECOMMENDATIONS FOR FUTURE WORK . 121...The detector developed at the Hughes Research Laboratories ( IDPC ) involves placing an interdigital metal electrode 53- 5 5 structure on top of a F...easier to perform with the IDPC detector. We believe the interdigital photoconductive detector has many advantages over existing detectors. First, the

  4. Continuity in Multi-Device Interaction

    DEFF Research Database (Denmark)

    Raptis, Dimitrios; Kjeldskov, Jesper; Skov, Mikael

    2016-01-01

    ’s Continuity. The study was done through surveying 3361 posts from technology web sites, discussion forums, and blogs, with a qualitative analysis of 1603 posts. Our findings present challenges in six themes of privacy, appropriation, customization, awareness, exclusion, and troubleshooting in relation...

  5. Effects of radiation on MOS structures and silicon devices

    International Nuclear Information System (INIS)

    Braeunig, D.; Fahrner, W.

    1983-02-01

    A comprehensive view of radiation effects on MOS structures and silicon devices is given. In the introduction, the interaction of radiation with semiconductor material is presented. In the next section, the electrical degradation of semiconductor devices due to this interaction is discussed. The commonly used hardening techniques are shown. The last section deals with testing of radiation hardness of devices. (orig.) [de

  6. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei.

    1980-01-01

    Purpose: To improve the plasma confining efficiency in a thermonuclear device having magnet coils using super-conducting wires by decreasing the uneven magnetic field resulted from current supply terminals and wirings. Constitution: Current introduction terminals of magnet coils using superconducting wires are short circuitted with a superconducting short circuit wire. Upon supplying current to the coils, the resistance of the coils is rendered superconductive and the resistance of the short circuit wire is rendered normally conductive heated by a heater and the switch is closed. In this case, most parts of the current are flown through the resistance of the coils and the switch is opened when the current arrives at a predetermined value to render the resistance of the short circuit wire superconductive. Then, the current transfers from the thyristor power source to the resistance of the short circuit wire, whereby the resistance of the coils and that of the short circuit wire from a permanent current loop. In this conditions, since current flows through the short circuit wire and the coils and not to the current introduction terminals, no uniform magnetic field is generated. (Kawakami, Y.)

  7. Reluctance device

    International Nuclear Information System (INIS)

    Claridge, A.N.; Smith, A.J.

    1983-01-01

    A reluctance device comprises two or more phases, each of which has a rotor mounted for rotation within a tubular member and an annular stator positioned externally of the tubular member. The rotor and the internal surface of the tubular member are each provided with aligned, axially spaced apart annular arrays of teeth, the teeth on the rotor confronting those on the tubular member in radially spaced apart relationship. The stator encloses a coil which, when electrically energised, creates a plurality of magnetic flux paths each of which extends radially between the rotor and stator via the confronting teeth and the tubular member, and axially along both the rotor and the portion of the stator located radially outwardly of the coil. The portion of the tubular member intermediate the teeth thereon is provided with a non-magnetic insert in order to resist the axial passage of magnetic flux therethrough. In one of the claims, the tubular member comprises a portion of a nuclear reactor which is adapted to contain a reactor control rod, the rotor constituting a portion of the drive mechanism for the control rod contained in operation within the tubular member. (author)

  8. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  9. Fast reactor recharging device

    International Nuclear Information System (INIS)

    Artemiev, L.N.; Kurilkin, V.V.

    1979-01-01

    Disclosure is made of a device for recharging a fast-neutron reactor, intended for the transfer of fuel assemblies and rods of the control and safety system, having profiled heads to be gripped on the outside. The device comprises storage drums whose compartments for rods of the control and safety system are identical to compartments for fuel assemblies. In order to store and transport rods of the control and safety system from the storage drums to the recharging mechanism provision is made for sleeve-type holders. When placed in such a holder, the dimensions of a rod of the control and safety system are equal to those of a fuel assembly. To join a holder to a rod of the control and safety system, on the open end of each holder there is mounted a collet, whereas on the surface of each rod of the control and safety system, close to its head, there is provided an encircling groove to interact with the collet. The grip of the recharging mechanism is provided with a stop interacting with the collet in order to open the latter and withdraw the safety and control system rod from its holder

  10. Progress and Prospects in Stretchable Electroluminescent Devices

    Directory of Open Access Journals (Sweden)

    Wang Jiangxin

    2017-03-01

    Full Text Available Stretchable electroluminescent (EL devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are

  11. HARD - The High Assurance Remote Authentication Device Project

    OpenAIRE

    2006-01-01

    The HARD project will build and evaluate a high assurance network access device. The purpose of this device is to provide an unforgeable trusted path with which network clients can securely interact with security-enabled remote servers.

  12. Proxemic Mobile Collocated Interactions

    DEFF Research Database (Denmark)

    Porcheron, Martin; Lucero, Andrés; Quigley, Aaron

    2016-01-01

    and their digital devices (i.e. the proxemic relationships). Building on the ideas of proxemic interactions, this workshop is motivated by the concept of ‘proxemic mobile collocated interactions’, to harness new or existing technologies to create engaging and interactionally relevant experiences. Such approaches......Recent research on mobile collocated interactions has been looking at situations in which collocated users engage in collaborative activities using their mobile devices. However, existing practices fail to fully account for the culturally-dependent spatial relationships between people...... in exploring proxemics and mobile collocated interactions....

  13. An Overview of Biofield Devices

    Science.gov (United States)

    Muehsam, David; Chevalier, Gaétan; Barsotti, Tiffany

    2015-01-01

    Advances in biophysics, biology, functional genomics, neuroscience, psychology, psychoneuroimmunology, and other fields suggest the existence of a subtle system of “biofield” interactions that organize biological processes from the subatomic, atomic, molecular, cellular, and organismic to the interpersonal and cosmic levels. Biofield interactions may bring about regulation of biochemical, cellular, and neurological processes through means related to electromagnetism, quantum fields, and perhaps other means of modulating biological activity and information flow. The biofield paradigm, in contrast to a reductionist, chemistry-centered viewpoint, emphasizes the informational content of biological processes; biofield interactions are thought to operate in part via low-energy or “subtle” processes such as weak, nonthermal electromagnetic fields (EMFs) or processes potentially related to consciousness and nonlocality. Biofield interactions may also operate through or be reflected in more well-understood informational processes found in electroencephalographic (EEG) and electrocardiographic (ECG) data. Recent advances have led to the development of a wide variety of therapeutic and diagnostic biofield devices, defined as physical instruments best understood from the viewpoint of a biofield paradigm. Here, we provide a broad overview of biofield devices, with emphasis on those devices for which solid, peer-reviewed evidence exists. A subset of these devices, such as those based upon EEG- and ECG-based heart rate variability, function via mechanisms that are well understood and are widely employed in clinical settings. Other device modalities, such a gas discharge visualization and biophoton emission, appear to operate through incompletely understood mechanisms and have unclear clinical significance. Device modes of operation include EMF-light, EMF-heat, EMF-nonthermal, electrical current, vibration and sound, physical and mechanical, intentionality and nonlocality

  14. News Quantum physics: German Physical Society spring meeting Journal access: American Physical Society's online journals will be available for free in all US high schools Award: High-school physics teacher receives American award for excellence Teacher training: Fobinet offers coordination of teacher-training activities Astronomy: Astronomy fans see stars at Astrofest Conference: Delegates enjoy the workshops and activities at CPD conference Forthcoming events

    Science.gov (United States)

    2011-05-01

    Quantum physics: German Physical Society spring meeting Journal access: American Physical Society's online journals will be available for free in all US high schools Award: High-school physics teacher receives American award for excellence Teacher training: Fobinet offers coordination of teacher-training activities Astronomy: Astronomy fans see stars at Astrofest Conference: Delegates enjoy the workshops and activities at CPD conference Forthcoming events

  15. Mixed Interaction Spaces

    DEFF Research Database (Denmark)

    Lykke-Olesen, Andreas; Eriksson, E.; Hansen, T.R.

    In this paper, we describe a new interaction technique for mobile devices named Mixed Interaction Space that uses the camera of the mobile device to track the position, size and rotation of a fixed-point. In this demonstration we will present a system that uses a hand-drawn circle, colored object...... or a person’s face as a fixed-point to determine the location of the device. We use these features as a 4 dimensional input vector to a set of different applications....

  16. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  17. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  18. Uranium-scintillator device

    International Nuclear Information System (INIS)

    Smith, S.D.

    1979-01-01

    The calorimeter subgroup of the 1977 ISABELLE Summer Workshop strongly recommended investigation of the uranium-scintillator device because of its several attractive features: (1) increased resolution for hadronic energy, (2) fast time response, (3) high density (i.e., 16 cm of calorimeter per interaction length), and, in comparison with uranium--liquid argon detectors, (4) ease of construction, (5) simple electronics, and (6) lower cost. The AFM group at the CERN ISR became interested in such a calorimeter for substantially the same reasons, and in the fall of 1977 carried out tests on a uranium-scintillator (U-Sc) calorimeter with the same uranium plates used in their 1974 studies of the uranium--liquid argon (U-LA) calorimeter. The chief disadvantage of the scintillator test was that the uranium plates were too small to fully contain the hadronic showers. However, since the scintillator and liquid argon tests were made with the plates, direct comparison of the two types of devices could be made

  19. Mobile Collocated Interactions

    DEFF Research Database (Denmark)

    Lucero, Andrés; Clawson, James; Lyons, Kent

    2015-01-01

    Mobile devices such as smartphones and tablets were originally conceived and have traditionally been utilized for individual use. Research on mobile collocated interactions has been looking at situations in which collocated users engage in collaborative activities using their mobile devices, thus...... going from personal/individual toward shared/multiuser experiences and interactions. However, computers are getting smaller, more powerful, and closer to our bodies. Therefore, mobile collocated interactions research, which originally looked at smartphones and tablets, will inevitably include ever......-smaller computers, ones that can be worn on our wrists or other parts of the body. The focus of this workshop is to bring together a community of researchers, designers and practitioners to explore the potential of extending mobile collocated interactions to the use of wearable devices....

  20. Dielectrokinetic chromatography and devices thereof

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-04-22

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  1. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  2. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  3. Power source device for thermonuclear device

    International Nuclear Information System (INIS)

    Ozaki, Akira.

    1992-01-01

    The present invention provides a small sized and economical power source device for a thermonuclear device. That is, the device comprises a conversion device having a rated power determined by a power required during a plasma current excitation period and a conversion device having a rated power determined by a power required during a plasma current maintaining period, connected in series to each other. Then, for the former conversion device, power is supplied from an electric power generator and, for the latter, power is supplied from a power system. With such a constitution, during the plasma electric current maintaining period for substantially continuous operation, it is possible to conduct bypassing paired operation for the former conversion device while the electric power generator is put under no load. Further, since a short period rated power may be suffice for the former conversion device and the electric power generator having the great rated power required for the plasma electric current excitation period, they can be reduced in the size and made economical. On the other hand, since the power required for the plasma current maintaining period is relatively small, the capacity of the continuous rated conversion device may be small, and the power can be received from the power system. (I.S.)

  4. Interaction region

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Interaction Region Group addressed the basic questions of how to collide the SLC beams, how to maximize and monitor the luminosity, and how to minimize the detector backgrounds at the interaction region. In practice, five subgroups evolved to study these questions. The final focus group provided three alternative designs to acheive the 1 to 2 micron beam spot size required by the SLC, as well as studying other problems including: eta, eta' matching from the collider arcs, the implementation of soft bends near the interaction region, beam emittance growth, and magnet tolerances in the final focus. The beam position monitor group proposed two devices, a strip line monitor, and a beamstrahlung monitor, to bring the beams into collision. The luminosity monitor group reviewed the possible QED processes that would be insensitive to weak interaction (Z 0 ) effects. The beam dumping group proposed locations for kicker and septum magnets in the final focus that would achieve a high dumping efficiency and would meet the desired beam tolerances at the Moller scattering target in the beam dump line. Working with the Polarization Group, the Moller experiment was designed into the beam dump beam line. A beam dump was proposed that would maintain radiation backgrounds (penetrating muons) at acceptible levels. The detector backgrounds group proposed soft-bend and masking configurations to shield the detector from synchrotron radiation from the hard/soft bends and from the final focus quadrupoles and evaluated the effectiveness of these designs for the three final focus optics designs. Backgrounds were also estimated from: large angle synchrotron radiation, local and distant beam-gas interactions, 2-photon interactions, and from neutrons and backscattered photons from the beamstrahlung dump

  5. Optoelectronic Devices Advanced Simulation and Analysis

    CERN Document Server

    Piprek, Joachim

    2005-01-01

    Optoelectronic devices transform electrical signals into optical signals and vice versa by utilizing the sophisticated interaction of electrons and light within micro- and nano-scale semiconductor structures. Advanced software tools for design and analysis of such devices have been developed in recent years. However, the large variety of materials, devices, physical mechanisms, and modeling approaches often makes it difficult to select appropriate theoretical models or software packages. This book presents a review of devices and advanced simulation approaches written by leading researchers and software developers. It is intended for scientists and device engineers in optoelectronics, who are interested in using advanced software tools. Each chapter includes the theoretical background as well as practical simulation results that help to better understand internal device physics. The software packages used in the book are available to the public, on a commercial or noncommercial basis, so that the interested r...

  6. Hot carrier degradation in semiconductor devices

    CERN Document Server

    2015-01-01

    This book provides readers with a variety of tools to address the challenges posed by hot carrier degradation, one of today’s most complicated reliability issues in semiconductor devices.  Coverage includes an explanation of carrier transport within devices and book-keeping of how they acquire energy (“become hot”), interaction of an ensemble of colder and hotter carriers with defect precursors, which eventually leads to the creation of a defect, and a description of how these defects interact with the device, degrading its performance. • Describes the intricacies of hot carrier degradation in modern semiconductor technologies; • Covers the entire hot carrier degradation phenomenon, including topics such as characterization, carrier transport, carrier-defect interaction, technological impact, circuit impact, etc.; • Enables detailed understanding of carrier transport, interaction of the carrier ensemble with the defect precursors, and an accurate assessment of how the newly created defects imp...

  7. CMOS and BiCMOS process integration and device characterization

    CERN Document Server

    El-Kareh, Badih

    2009-01-01

    Covers both the theoretical and practical aspects of modern silicon devices and the relationship between their electrical properties and processing conditions. This book also covers silicon devices and integrated process technologies. It discusses modern silicon devices, their characteristics, and interactions with process parameters.

  8. On Emulation of Flueric Devices in Excitable Chemical Medium.

    Directory of Open Access Journals (Sweden)

    Andrew Adamatzky

    Full Text Available Flueric devices are fluidic devices without moving parts. Fluidic devices use fluid as a medium for information transfer and computation. A Belousov-Zhabotinsky (BZ medium is a thin-layer spatially extended excitable chemical medium which exhibits travelling excitation wave-fronts. The excitation wave-fronts transfer information. Flueric devices compute via jets interaction. BZ devices compute via excitation wave-fronts interaction. In numerical model of BZ medium we show that functions of key flueric devices are implemented in the excitable chemical system: signal generator, and, xor, not and nor Boolean gates, delay elements, diodes and sensors. Flueric devices have been widely used in industry since late 1960s and are still employed in automotive and aircraft technologies. Implementation of analog of the flueric devices in the excitable chemical systems opens doors to further applications of excitation wave-based unconventional computing in soft robotics, embedded organic electronics and living technologies.

  9. On Emulation of Flueric Devices in Excitable Chemical Medium.

    Science.gov (United States)

    Adamatzky, Andrew

    2016-01-01

    Flueric devices are fluidic devices without moving parts. Fluidic devices use fluid as a medium for information transfer and computation. A Belousov-Zhabotinsky (BZ) medium is a thin-layer spatially extended excitable chemical medium which exhibits travelling excitation wave-fronts. The excitation wave-fronts transfer information. Flueric devices compute via jets interaction. BZ devices compute via excitation wave-fronts interaction. In numerical model of BZ medium we show that functions of key flueric devices are implemented in the excitable chemical system: signal generator, and, xor, not and nor Boolean gates, delay elements, diodes and sensors. Flueric devices have been widely used in industry since late 1960s and are still employed in automotive and aircraft technologies. Implementation of analog of the flueric devices in the excitable chemical systems opens doors to further applications of excitation wave-based unconventional computing in soft robotics, embedded organic electronics and living technologies.

  10. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  11. Devices for hearing loss

    Science.gov (United States)

    ... the sounds you want to hear. Assistive listening devices bring certain sounds directly to your ears. This can ... a small room or on a stage. Other devices can bring the sound from your TV, radio, or music ...

  12. Novel Magnetic Devices

    National Research Council Canada - National Science Library

    Schuller, Ivan

    2007-01-01

    ...: ballistic magnetoresistance, magnetic field proximity effect and spin drag. These three phenomena would then be exploited for the design of novel device architectures and to investigate the physical principles behind these devices...

  13. Tactile Feedback for Above-Device Gesture Interfaces

    OpenAIRE

    Freeman, Euan; Brewster, Stephen; Lantz, Vuokko

    2014-01-01

    Above-device gesture interfaces let people interact in the space above mobile devices using hand and finger movements. For example, users could gesture over a mobile phone or wearable without having to use the touchscreen. We look at how above-device interfaces can also give feedback in the space over the device. Recent haptic and wearable technologies give new ways to provide tactile feedback while gesturing, letting touchless gesture interfaces give touch feedback. In this paper we take a f...

  14. Smart devices are different

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Bhattacharya, Sourav

    2015-01-01

    research results. This is due to variations in training and test device hardware and their operating system characteristics among others. In this paper, we systematically investigate sensor-, device- and workload-specific heterogeneities using 36 smartphones and smartwatches, consisting of 13 different...... device models from four manufacturers. Furthermore, we conduct experiments with nine users and investigate popular feature representation and classification techniques in HAR research. Our results indicate that on-device sensor and sensor handling heterogeneities impair HAR performances significantly...

  15. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  16. Rooting an Android Device

    Science.gov (United States)

    2015-09-01

    1. Overview The purpose of this document is to demonstrate how to gain administrative privileges on an Android device. The term “rooting” is...is applicable for the Samsung Galaxy S3 as well as many other Android devices, but there are several steps involved in rooting an Android device (as...root access has been granted. 4. Conclusion This document serves as a tutorial on how to grant user administrative privilege to an Android device by

  17. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  18. Radioactive waste processing device

    International Nuclear Information System (INIS)

    Inaguma, Masahiko; Takahara, Nobuaki; Hara, Satomi.

    1996-01-01

    In a processing device for filtering laundry liquid wastes and shower drains incorporated with radioactive materials, a fiber filtration device is disposed and an activated carbon filtration device is also disposed subsequent to the fiber filtration device. In addition, a centrifugal dewatering device is disposed for dewatering spent granular activated carbon in the activated carbon filtration device, and a minute filtering device is disposed for filtering the separated dewatering liquid. Filtrates filtered by the minute filtration device are recovered in a collecting tank. Namely, at first, suspended solid materials in laundry liquid wastes and shower drains are captured, and then, ingredients concerning COD are adsorbed in the activated carbon filtration device. The radioactive liquid wastes of spent granular activated carbon in the activated carbon filtration device are reduced by dewatering them by the centrifugal dewatering device, and then the granular activated carbon is subjected to an additional processing. Further, it is separated by filtration using the minute filtration device and removed as cakes. Since the filtrates are recovered to the collecting tank and filtered again, the water quality of the drains is not degraded. (N.H.)

  19. Inspection device in liquid

    International Nuclear Information System (INIS)

    Nagaoka, Etsuo.

    1996-01-01

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  20. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  1. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  2. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  3. Articulating feedstock delivery device

    Science.gov (United States)

    Jordan, Kevin

    2013-11-05

    A fully articulable feedstock delivery device that is designed to operate at pressure and temperature extremes. The device incorporates an articulating ball assembly which allows for more accurate delivery of the feedstock to a target location. The device is suitable for a variety of applications including, but not limited to, delivery of feedstock to a high-pressure reaction chamber or process zone.

  4. Interactive Workspaces

    DEFF Research Database (Denmark)

    Mogensen, Preben Holst

    augmented reality, interactive building elements, and mobile devices to support new ways of working in a diversity of application domains with work situations ranging from individual work, through local collaboration, to distributed collaboration. The work situations may take place in offices/project rooms......Many application domains such as architecture, engineering, industrial design, city planning, environmental supervision, health care etc. share the properties of users working collaboratively with complex mixtures of physical and digital materials. Studies in such domains show that it is hard...... to maintain and integrate these heterogeneous materials in traditional desktop computing environments. Our thesis is that pervasive computing technologies can be developed to support a more natural user collaboration in a rich variety of application. This may be achieved by going beyond the traditional...

  5. Device for guiding various diameter size cable

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, I.M.; Klauzer, L.P.; Yeganov, L.I.; Zaripov, A.M.

    1982-01-30

    A design is submitted for a device to guide cable of various diameters. This device consists of a profiled multiple-pass roller, and clamps for uniting cut cable. This design is simplified by allowing both the rollers and their supports to rotate on the roller axis thus facilitating interaction with the clamps. The working surface of the supports is evolute while the outside surfaces have screw-channels for transfering the cable from one roller pass to the other.

  6. Role of management devices in enacting strategy

    DEFF Research Database (Denmark)

    Harritz, Daniel

    2016-01-01

    the SSC’s creation. Originality/value - This study is the first to use a performative method to highlight the temporary and local nature of enacting strategic decisions to construct an SSC in the public sector. Keywords: Management control, SSC, strategic change, actor-network theory, organizational......Purpose - This study illustrates the role of management devices in enacting strategy and strategic decisions, resulting in the development of a Shared Service Centre (SSC) in a Danish municipality. It shows how devices interact in defending, rejecting and reframing strategy, leading to the closure...... the active role of non-human entities, such as management devices, in enacting and reformulating strategy. Findings - Different devices have become key actants in shaping and formulating the new strategy in the municipality and the strategic decision to construct a SSC. However, different devices mobilise...

  7. Adaptive Text Entry for Mobile Devices

    DEFF Research Database (Denmark)

    Proschowsky, Morten Smidt

    The reduced size of many mobile devices makes it difficult to enter text with them. The text entry methods are often slow or complicated to use. This affects the performance and user experience of all applications and services on the device. This work introduces new easy-to-use text entry methods...... for mobile devices and a framework for adaptive context-aware language models. Based on analysis of current text entry methods, the requirements to the new text entry methods are established. Transparent User guided Prediction (TUP) is a text entry method for devices with one dimensional touch input. It can...... be touch sensitive wheels, sliders or similar input devices. The interaction design of TUP is done with a combination of high level task models and low level models of human motor behaviour. Three prototypes of TUP are designed and evaluated by more than 30 users. Observations from the evaluations are used...

  8. Silicon solid state devices and radiation detection

    CERN Document Server

    Leroy, Claude

    2012-01-01

    This book addresses the fundamental principles of interaction between radiation and matter, the principles of working and the operation of particle detectors based on silicon solid state devices. It covers a broad scope with respect to the fields of application of radiation detectors based on silicon solid state devices from low to high energy physics experiments including in outer space and in the medical environment. This book covers stateof- the-art detection techniques in the use of radiation detectors based on silicon solid state devices and their readout electronics, including the latest developments on pixelated silicon radiation detector and their application.

  9. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  10. Effective modelling of acoustofluidic devices

    DEFF Research Database (Denmark)

    Ley, Mikkel Wennemoes Hvitfeld

    , and 3) acoustic streaming patterns in the devices considered in model 2). 1) We derive an effective model for numerical studies of hydrodynamic particle-particle interactions in microfluidic high-concentration suspensions. A suspension of microparticles placed in a microfluidic channel and influenced......, and of the momentum transfer between the particles and the suspension. 2) We derive a full 3D numerical model for the coupled acoustic fields in mm-sized water-filled glass capillaries, calculating pressure field in the liquid coupled to the displacement field of the glass channel, taking into account mixed standing...... for the acoustic field in glass capillary devices derived in 2), we make an effective model for calculating the acoustic streaming velocity in 3D. To do this, we use recent analytical results that allows calculation of the acoustic streaming field resulting from channel-wall oscillations in any direction...

  11. Interaction Design for Public Spaces

    DEFF Research Database (Denmark)

    Kortbek, Karen Johanne

    2008-01-01

    In this abstract I describe the doctorial research project "Interaction Design for Public Spaces". The objective of the project is to explore and design interaction contexts in culture related public spaces such as museums, experience centres and festivals. As a perspective on this domain, I...... will focus on the usage of the body as an interaction device. Furthermore, the project will involve a dramaturgic take on communication and design of interactive systems in the pursuit of new ways to stage the interactive contexts. The outcome of the project will be guidelines and conceptual frameworks which...... will help interaction designers when designing for bodily movement, and communicating and staging interactive content in public spaces....

  12. Multifunctional Energy Storage and Conversion Devices.

    Science.gov (United States)

    Huang, Yan; Zhu, Minshen; Huang, Yang; Pei, Zengxia; Li, Hongfei; Wang, Zifeng; Xue, Qi; Zhi, Chunyi

    2016-10-01

    Multifunctional energy storage and conversion devices that incorporate novel features and functions in intelligent and interactive modes, represent a radical advance in consumer products, such as wearable electronics, healthcare devices, artificial intelligence, electric vehicles, smart household, and space satellites, etc. Here, smart energy devices are defined to be energy devices that are responsive to changes in configurational integrity, voltage, mechanical deformation, light, and temperature, called self-healability, electrochromism, shape memory, photodetection, and thermal responsivity. Advisable materials, device designs, and performances are crucial for the development of energy electronics endowed with these smart functions. Integrating these smart functions in energy storage and conversion devices gives rise to great challenges from the viewpoint of both understanding the fundamental mechanisms and practical implementation. Current state-of-art examples of these smart multifunctional energy devices, pertinent to materials, fabrication strategies, and performances, are highlighted. In addition, current challenges and potential solutions from materials synthesis to device performances are discussed. Finally, some important directions in this fast developing field are considered to further expand their application. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  14. Smart portable rehabilitation devices.

    Science.gov (United States)

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  15. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  16. Mobile Device Encryption Systems

    OpenAIRE

    Teufl , Peter; Zefferer , Thomas; Stromberger , Christof

    2013-01-01

    Part 4: Software Security; International audience; The initially consumer oriented iOS and Android platforms, and the newly available Windows Phone 8 platform start to play an important role within business related areas. Within the business context, the devices are typically deployed via mobile device management (MDM) solutions, or within the bring-your-own-device (BYOD) context. In both scenarios, the security depends on many platform security functions, such as permission systems, manageme...

  17. Temperature indicating device

    International Nuclear Information System (INIS)

    Angus, J.P.; Salt, D.

    1988-01-01

    A temperature indicating device comprises a plurality of planar elements some undergoing a reversible change in appearance at a given temperature the remainder undergoing an irreversible change in appearance at a given temperature. The device is useful in indicating the temperature which an object has achieved as well as its actual temperature. The reversible change is produced by liquid crystal devices. The irreversible change is produced by an absorbent surface carrying substances e.g. waxes which melt at predetermined temperatures and are absorbed by the surface; alternatively paints may be used. The device is used for monitoring processes of encapsulation of radio active waste. (author)

  18. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  19. Recoil transporter devices

    International Nuclear Information System (INIS)

    Madhavan, N.

    2005-01-01

    The study of sparsely produced nuclear reaction products in the direction of intense primary beam is a challenging task, the pursuit of which has given rise to the advent or several types of selective devices. These range from a simple parallel plate electrostatic deflector to state-of-the-art electromagnetic separators. There is no single device which can satisfy all the requirements of an ideal recoil transporter, simultaneously. An overview of such devices and their building blocks is presented, which may help in the proper choice of the device as per the experimental requirements. (author)

  20. Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — This searchable database contains establishments (engaged in the manufacture, preparation, propagation, compounding, assembly, or processing of medical devices...

  1. Virtual Training Devices Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Training Devices (VTD) Laboratory at the Life Cycle Software Engineering Center, Picatinny Arsenal, provides a software testing and support environment...

  2. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  3. Repairing method and device for thermonuclear device

    International Nuclear Information System (INIS)

    Sakurai, Akiko; Masumoto, Hiroshi; Tachikawa, Nobuo.

    1995-01-01

    The present invention provides a method of and a device for repairing a first wall and a divertor disposed in a vacuum vessel of a thermonuclear device. Namely, an armour tile of the divertor secured, by a brazing material, in a vacuum vessel of the thermonuclear device in which high temperature plasmas of deuterium and tritium are confined to cause fusion reaction is induction-heated or heated by microwaves to melt the brazing material. Only the armour tile is thus exchanged by its attachment/detachment. This device comprises, in the vacuum vessel, an armour tile attaching/detaching manipulator and a repairing manipulator comprising a heating manipulator having induction heating coils at the top end thereof. Induction heating coils are connected to an AC power source. According to the present invention, the armour tile is exchanged without taking the divertor out of the vacuum vessel. Therefore, cutting of a divertor cooling tube for taking the divertor out of the vacuum vessel and re-welding of the divertor for attaching it to the vacuum vessel again are no more necessary. (I.S.)

  4. Transient electro-thermal modeling of bipolar power semiconductor devices

    CERN Document Server

    Gachovska, Tanya Kirilova; Du, Bin

    2013-01-01

    This book presents physics-based electro-thermal models of bipolar power semiconductor devices including their packages, and describes their implementation in MATLAB and Simulink. It is a continuation of our first book Modeling of Bipolar Power Semiconductor Devices. The device electrical models are developed by subdividing the devices into different regions and the operations in each region, along with the interactions at the interfaces, are analyzed using the basic semiconductor physics equations that govern device behavior. The Fourier series solution is used to solve the ambipolar diffusio

  5. Ferromagnetic Swimmers - Devices and Applications

    Science.gov (United States)

    Hamilton, Joshua; Petrov, Peter; Winlove, C. Peter; Gilbert, Andrew; Bryan, Matthew; Ogrin, Feodor

    2017-11-01

    Microscopic swimming devices hold promise for radically new applications in lab-on-a-chip and microfluidic technology, diagnostics and drug delivery etc. We propose a new class of autonomous ferromagnetic swimming devices, actuated and controlled solely by an oscillating magnetic field. Experimentally, these devices (3.6 mm) are based on a pair of interacting ferromagnetic particles of different size and different anisotropic properties joined by an elastic link and actuated by an external time-dependent magnetic field. The net motion is generated through a combination of dipolar interparticle gradient forces, time-dependent torque and hydrodynamic coupling. We investigate the dynamic performance of a prototype (3.6 mm) of the ferromagnetic swimmer in fluids of different viscosity as a function of the external field parameters and demonstrate stable propulsion over a wide range of Reynolds numbers. Manipulation of the external magnetic field resulted in robust control over the speed and direction of propulsion. We also demonstrate our ferromagnetic swimmer working as a macroscopic prototype of a microfluidic pump. By physically tethering the swimmer, instead of swimming, the swimmer generates a directional flow of liquid around itself.

  6. Metamaterial mirrors in optoelectronic devices

    KAUST Repository

    Esfandyarpour, Majid

    2014-06-22

    The phase reversal that occurs when light is reflected from a metallic mirror produces a standing wave with reduced intensity near the reflective surface. This effect is highly undesirable in optoelectronic devices that use metal films as both electrical contacts and optical mirrors, because it dictates a minimum spacing between the metal and the underlying active semiconductor layers, therefore posing a fundamental limit to the overall thickness of the device. Here, we show that this challenge can be circumvented by using a metamaterial mirror whose reflection phase is tunable from that of a perfect electric mirror († = €) to that of a perfect magnetic mirror († = 0). This tunability in reflection phase can also be exploited to optimize the standing wave profile in planar devices to maximize light-matter interaction. Specifically, we show that light absorption and photocurrent generation in a sub-100 nm active semiconductor layer of a model solar cell can be enhanced by ∼20% over a broad spectral band. © 2014 Macmillan Publishers Limited.

  7. Metamaterial mirrors in optoelectronic devices

    KAUST Repository

    Esfandyarpour, Majid; Garnett, Erik C.; Cui, Yi; McGehee, Michael D.; Brongersma, Mark L.

    2014-01-01

    The phase reversal that occurs when light is reflected from a metallic mirror produces a standing wave with reduced intensity near the reflective surface. This effect is highly undesirable in optoelectronic devices that use metal films as both electrical contacts and optical mirrors, because it dictates a minimum spacing between the metal and the underlying active semiconductor layers, therefore posing a fundamental limit to the overall thickness of the device. Here, we show that this challenge can be circumvented by using a metamaterial mirror whose reflection phase is tunable from that of a perfect electric mirror († = €) to that of a perfect magnetic mirror († = 0). This tunability in reflection phase can also be exploited to optimize the standing wave profile in planar devices to maximize light-matter interaction. Specifically, we show that light absorption and photocurrent generation in a sub-100 nm active semiconductor layer of a model solar cell can be enhanced by ∼20% over a broad spectral band. © 2014 Macmillan Publishers Limited.

  8. Nanoscale device physics science and engineering fundamentals

    CERN Document Server

    Tiwari, Sandip

    2017-01-01

    Nanoscale devices are distinguishable from the larger microscale devices in their specific dependence on physical phenomena and effects that are central to their operation. The size change manifests itself through changes in importance of the phenomena and effects that become dominant and the changes in scale of underlying energetics and response. Examples of these include classical effects such as single electron effects, quantum effects such as the states accessible as well as their properties; ensemble effects ranging from consequences of the laws of numbers to changes in properties arising from different magnitudes of the inter-actions, and others. These interactions, with the limits placed on size, make not just electronic, but also magnetic, optical and mechanical behavior interesting, important and useful. Connecting these properties to the behavior of devices is the focus of this textbook. Description of the book series: This collection of four textbooks in the Electroscience series span the undergrad...

  9. Pointing Device Performance in Steering Tasks.

    Science.gov (United States)

    Senanayake, Ransalu; Goonetilleke, Ravindra S

    2016-06-01

    Use of touch-screen-based interactions is growing rapidly. Hence, knowing the maneuvering efficacy of touch screens relative to other pointing devices is of great importance in the context of graphical user interfaces. Movement time, accuracy, and user preferences of four pointing device settings were evaluated on a computer with 14 participants aged 20.1 ± 3.13 years. It was found that, depending on the difficulty of the task, the optimal settings differ for ballistic and visual control tasks. With a touch screen, resting the arm increased movement time for steering tasks. When both performance and comfort are considered, whether to use a mouse or a touch screen for person-computer interaction depends on the steering difficulty. Hence, a input device should be chosen based on the application, and should be optimized to match the graphical user interface. © The Author(s) 2016.

  10. Dynamic training devices in CRM training

    Science.gov (United States)

    Lawver, J.

    1984-01-01

    Pilot training effectiveness and flying safety of a seasonal tour flight company are described. The change from single pilot to two pilot operated twin otters is examined. The use of the ATC 810 training device, its possibilities and training capacity is outlined. Problem areas which may arise, emergency system and pilot/passenger interaction are analyzed.

  11. Users want simple control over device selection

    NARCIS (Netherlands)

    Misker, J.M.V.; Lindenberg, J.; Neerincx, M.A.

    2005-01-01

    When users want to combine various resources in an ambient intelligent environment in an ad hoc manner, they need to be able to identify and select these resources. We conducted an experiment to study various user interaction styles for combining input and output devices in an ambient intelligent

  12. Partial Device Fingerprints

    NARCIS (Netherlands)

    Ciere, M.; Hernandez Ganan, C.; van Eeten, M.J.G.

    2017-01-01

    In computing, remote devices may be identified by means of device fingerprinting, which works by collecting a myriad of clientside attributes such as the device’s browser and operating system version, installed plugins, screen resolution, hardware artifacts, Wi-Fi settings, and anything else

  13. Unconventional Quantum Computing Devices

    OpenAIRE

    Lloyd, Seth

    2000-01-01

    This paper investigates a variety of unconventional quantum computation devices, including fermionic quantum computers and computers that exploit nonlinear quantum mechanics. It is shown that unconventional quantum computing devices can in principle compute some quantities more rapidly than `conventional' quantum computers.

  14. Magnetic sensor device

    NARCIS (Netherlands)

    2009-01-01

    The present invention provides a sensor device and a method for detg. the presence and/or amt. of target moieties in a sample fluid, the target moieties being labeled with magnetic or magnetizable objects. The sensor device comprises a magnetic field generating means adapted for applying a retention

  15. Process control device

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kobayashi, Hiroshi.

    1994-01-01

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.)

  16. EPICS GPIB device support

    International Nuclear Information System (INIS)

    Winans, J.

    1993-01-01

    A GPIB device support module is used to provide access to the operating parameters of a GPIB device. GPIB devices may be accessed via National Instruments 1014 cards or via Bitbus Universal Gateways. GPIB devices typically have many parameters, each of which may be thought of in terms of the standard types of database records available in EPICS. It is the job of the device support module designer to decide how the mapping of these parameters will be made to the available record types. Once this mapping is complete, the device support module may be written. The writing of the device support module consists primarily of the construction of a parameter table. This table is used to associate the database record types with the operating parameters of the GPIB instrument. Other aspects of module design include the handling of SRQ events and errors. SRQ events are made available to the device support module if so desired. The processing of an SRQ event is completely up to the designer of the module. They may be ignored, tied to event based record processing, or anything else the designer wishes. Error conditions may be handled in a similar fashion

  17. Operation control device for nuclear power plants

    International Nuclear Information System (INIS)

    Suto, Osamu.

    1982-01-01

    Purpose: To render the controlling functions of a central control console more centralized by constituting the operation controls for a nuclear power plant with computer systems having substantially independent functions such as those of plant monitor controls, reactor monitor management and CRT display and decreasing interactions between each of the systems. Constitution: An input/output device for the input of process data for a nuclear power plant and indication data for a plant control console is connected to a plant supervisory and control computer system and a display computer system, the plant supervisory control computer system and a reactor and management computer system are connected with a CRT display control device, a printer and a CRT display input/output device, and the display computer system is connected with the CRT display control device and the CRT display unit on the central control console, whereby process input can be processed and displayed at high speed. (Yoshino, Y.)

  18. Chemically sensitive interfaces on SAW devices

    Energy Technology Data Exchange (ETDEWEB)

    Ricco, A.J.; Martin, S.J. [Sandia National Labs., Albuquerque, NM (United States); Crooks, R.M.; Xu, Chuanjing [Texas A and M Univ., College Station, TX (United States); Allred, R.E. [Adherent Technologies, Inc., Albuquerque, NM (United States)

    1993-11-01

    Using surface acoustic wave (SAW) devices, three approaches to the effective use of chemically sensitive interfaces that are not highly chemically selective have been examined: (1) molecular identification from time-resolved permeation transients; (2) using multifrequency SAW devices to determine the frequency dependence of analyte/film interactions; (3) use of an array of SAW devices bearing diverse chemically sensitive interfaces to produce a distinct response pattern for each analyte. In addition to their well-known sensitivity to mass changes (0.0035 monolayer of N{sub 2} can be measured), SAW devices respond to the mechanical and electronic properties of thin films, enhancing response information content but making a thorough understanding of the perturbation critical. Simultaneous measurement of changes in frequency and attenuation, which can provide the information necessary to determine the type of perturbation, are used as part of the above discrimination schemes.

  19. Building devices from colloidal quantum dots.

    Science.gov (United States)

    Kagan, Cherie R; Lifshitz, Efrat; Sargent, Edward H; Talapin, Dmitri V

    2016-08-26

    The continued growth of mobile and interactive computing requires devices manufactured with low-cost processes, compatible with large-area and flexible form factors, and with additional functionality. We review recent advances in the design of electronic and optoelectronic devices that use colloidal semiconductor quantum dots (QDs). The properties of materials assembled of QDs may be tailored not only by the atomic composition but also by the size, shape, and surface functionalization of the individual QDs and by the communication among these QDs. The chemical and physical properties of QD surfaces and the interfaces in QD devices are of particular importance, and these enable the solution-based fabrication of low-cost, large-area, flexible, and functional devices. We discuss challenges that must be addressed in the move to solution-processed functional optoelectronic nanomaterials. Copyright © 2016, American Association for the Advancement of Science.

  20. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  1. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  2. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  3. Metallic spintronic devices

    CERN Document Server

    Wang, Xiaobin

    2014-01-01

    Metallic Spintronic Devices provides a balanced view of the present state of the art of metallic spintronic devices, addressing both mainstream and emerging applications from magnetic tunneling junction sensors and spin torque oscillators to spin torque memory and logic. Featuring contributions from well-known and respected industrial and academic experts, this cutting-edge work not only presents the latest research and developments but also: Describes spintronic applications in current and future magnetic recording devicesDiscusses spin-transfer torque magnetoresistive random-access memory (STT-MRAM) device architectures and modelingExplores prospects of STT-MRAM scaling, such as detailed multilevel cell structure analysisInvestigates spintronic device write and read optimization in light of spintronic memristive effectsConsiders spintronic research directions based on yttrium iron garnet thin films, including spin pumping, magnetic proximity, spin hall, and spin Seebeck effectsProposes unique solutions for ...

  4. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  5. Power calculation of grading device in desintegrator

    Science.gov (United States)

    Bogdanov, V. S.; Semikopenko, I. A.; Vavilov, D. V.

    2018-03-01

    This article describes the analytical method of measuring the secondary power consumption, necessitated by the installation of a grading device in the peripheral part of the grinding chamber in the desintegrator. There is a calculation model for defining the power input of the disintegrator increased by the extra power demand, required to rotate the grading device and to grind the material in the area between the external row of hammers and the grading device. The work has determined the inertia moments of a cylindrical section of the grading device with armour plates. The processing capacity of the grading device is adjusted to the conveying capacity of the auger feeder. The grading device enables one to increase the concentration of particles in the peripheral part of the grinding chamber and the amount of interaction between particles and armour plates as well as the number of colliding particles. The perforated sections provide the output of the ground material with the proper size granules, which together with the effects of armour plates, improves the efficiency of grinding. The power demand to rotate the grading device does not exceed the admissible value.

  6. Baking exhaustion device in thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Mitsunori.

    1987-02-02

    Purpose: To rapidly remove tritium and impurity from the vacuum region in the access port of the baking exhaustion device in a thermonuclear device. Constitution: Each of the gaps at the boundary between a fixed shielding member and a blanket module and at the boundary between the blanket and a divertor is made extremely small so as to minimize the neutron streaming from plasmas. Accordingly, in the case of evacuating the vacuum region in the access port, the gap conductance is extremely poor and the exhaustion speed is low. Then, baking pipeways for flowing high temperature fluids are embedded to the surface layer at the position facing to the vacuum region and the plasma evacuation duct and the vacuum region are connected with an evacuation duct of the access port. By flowing high temperature fluids in the pipeways and conducting evacuation, baking exhaustion can be carried out rapidly. (Kamimura, M.).

  7. Plasma facing device of thermonuclear device

    International Nuclear Information System (INIS)

    Sumita, Hideo; Ioki, Kimihiro.

    1993-01-01

    The present invention improves integrity of thermal structures of a plasma facing device. That is, in the plasma facing device, an armour block portion from a metal cooling pipe to a carbon material comprises a mixed material of the metal as the constituent material of the cooling pipe and ceramics. Then, the mixing ratio of the composition is changed continuously or stepwise to suppress peakings of remaining stresses upon production and thermal stresses upon exertion of thermal loads. Accordingly, thermal integrity of the structural materials can further be improved. In this case, a satisfactory characteristic can be obtained also by using ceramics instead of carbon for the mixed material, and the characteristic such as heat expansion coefficient is similar to that of the armour tile. (I.S.)

  8. A study on electromechanical carbon nanotube memory devices

    International Nuclear Information System (INIS)

    Kang, Jeong Won; Hwang, Ho Jung

    2005-01-01

    Electromechanical operations of carbon-nanotube (CNT) bridge memory device were investigated by using atomistic simulations based on empirical potentials. The nanotube-bridge memory device was operated by the electrostatic and the van der Waals forces acting on the nanotube-bridge. For the CNT bridge memory device, the van der Waals interactions between the CNT bridge and the oxide were very important. As the distance between the CNT bridge and the oxide decreased and the van der Waals interaction energy increased, the pull-in bias of the CNT-bridge decreased and the nonvolatility of the nanotube-bridge memory device increased, while the pull-out voltages increased. When the materials composed of the oxide film are different, since the van der Waals interactions must be also different, the oxide materials must be carefully selected for the CNT-bridge memory device to work as a nonvolatile memory.

  9. Mobile Collocated Interactions With Wearables

    DEFF Research Database (Denmark)

    Lucero, Andrés; Wilde, Danielle; Robinson, Simon

    2015-01-01

    Research on mobile collocated interactions has been looking at situations in which collocated users engage in collaborative activities using their mobile devices, thus going from personal/individual toward shared/multiuser experiences and interactions. However, computers are getting smaller, more...

  10. Transformations: Mobile Interaction & Language Learning

    Science.gov (United States)

    Carroll, Fiona; Kop, Rita; Thomas, Nathan; Dunning, Rebecca

    2015-01-01

    Mobile devices and the interactions that these technologies afford have the potential to change the face and nature of education in our schools. Indeed, mobile technological advances are seen to offer better access to educational material and new interactive ways to learn. However, the question arises, as to whether these new technologies are…

  11. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  12. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  13. Fuel pattern recognition device

    International Nuclear Information System (INIS)

    Sato, Tomomi.

    1995-01-01

    The device of the present invention monitors normal fuel exchange upon fuel exchanging operation carried out in a reactor of a nuclear power plant. Namely, a fuel exchanger is movably disposed to the upper portion of the reactor and exchanges fuels. An exclusive computer receives operation signals of the fuel exchanger during operation as inputs, and outputs reactor core fuel pattern information signals to a fuel arrangement diagnosis device. An underwater television camera outputs image signals of a fuel pattern in the reactor core to an image processing device. If there is any change in the image signals for the fuel pattern as a result of the fuel exchange operation of the fuel exchanger, the image processing device outputs the change as image signals to the fuel pattern diagnosis device. The fuel pattern diagnosis device compares the pattern information signals from the exclusive computer with the image signals from the image processing device, to diagnose the result of the fuel exchange operation performed by the fuel exchanger and inform the diagnosis by means of an image display. (I.S.)

  14. The conversational interface talking to smart devices

    CERN Document Server

    McTear, Michael; Griol, David

    2016-01-01

    This book provides a comprehensive introduction to the conversational interface, which is becoming the main mode of interaction with virtual personal assistants, smart devices, various types of wearables, and social robots. The book consists of four parts: Part I presents the background to conversational interfaces, examining past and present work on spoken language interaction with computers; Part II covers the various technologies that are required to build a conversational interface along with practical chapters and exercises using open source tools; Part III looks at interactions with smart devices, wearables, and robots, and then goes on to discusses the role of emotion and personality in the conversational interface; Part IV examines methods for evaluating conversational interfaces and discusses future directions. · Presents a comprehensive overview of the various technologies that underlie conversational user interfaces; · Combines descriptions of conversational user interface technologies with a gui...

  15. Diamond semiconducting devices

    International Nuclear Information System (INIS)

    Polowczyk, M.; Klugmann, E.

    1999-01-01

    Many efforts to apply the semiconducting diamond for construction of electronic elements: resistors, thermistors, photoresistors, piezoresistors, hallotrons, pn diodes, Schottky diodes, IMPATT diodes, npn transistor, MESFETs and MISFETs are reviewed. Considering the possibilities of acceptor and donor doping, electrical resistivity and thermal conductivity of diamond as well as high electric-field breakdown points, that diamond devices could be used at about 30-times higher frequency and more then 8200 times power than silicon devices. Except that, due to high heat resistant of diamond, it is concluded that diamond devices can be used in environment at high temperature, range of 600 o C. (author)

  16. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  17. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  18. Evolution of atherectomy devices.

    Science.gov (United States)

    Al Khoury, G; Chaer, R

    2011-08-01

    Percutaneous atherectomy provides an alternative approach to the endovascular treatment of peripheral atherosclerotic occlusive disease beyond angioplasty and stenting, and has the theoretical advantage of lesion debulking and minimizing barotrauma to the vessel wall. Atherectomy has evolved greatly during the last decade, with currently four FDA approved devices for the treatment of peripheral arterial disease. Several reports have focused on the initial technical success rates, and demonstrated the safety and short as well as mid-term efficacy of atherectomy devices. This article will review the evolution of current atherectomy devices and the associated literature.

  19. Introduction to Semiconductor Devices

    Science.gov (United States)

    Brennan, Kevin F.

    2005-03-01

    This volume offers a solid foundation for understanding the most important devices used in the hottest areas of electronic engineering today, from semiconductor fundamentals to state-of-the-art semiconductor devices in the telecommunications and computing industries. Kevin Brennan describes future approaches to computing hardware and RF power amplifiers, and explains how emerging trends and system demands of computing and telecommunications systems influence the choice, design and operation of semiconductor devices. In addition, he covers MODFETs and MOSFETs, short channel effects, and the challenges faced by continuing miniaturization. His book is both an excellent senior/graduate text and a valuable reference for practicing engineers and researchers.

  20. Proton therapy device

    International Nuclear Information System (INIS)

    Tronc, D.

    1994-01-01

    The invention concerns a proton therapy device using a proton linear accelerator which produces a proton beam with high energies and intensities. The invention lies in actual fact that the proton beam which is produced by the linear accelerator is deflected from 270 deg in its plan by a deflecting magnetic device towards a patient support including a bed the longitudinal axis of which is parallel to the proton beam leaving the linear accelerator. The patient support and the deflecting device turn together around the proton beam axis while the bed stays in an horizontal position. The invention applies to radiotherapy. 6 refs., 5 figs

  1. Nanoelectronic device applications handbook

    CERN Document Server

    Morris, James E

    2013-01-01

    Nanoelectronic Device Applications Handbook gives a comprehensive snapshot of the state of the art in nanodevices for nanoelectronics applications. Combining breadth and depth, the book includes 68 chapters on topics that range from nano-scaled complementary metal-oxide-semiconductor (CMOS) devices through recent developments in nano capacitors and AlGaAs/GaAs devices. The contributors are world-renowned experts from academia and industry from around the globe. The handbook explores current research into potentially disruptive technologies for a post-CMOS world.These include: Nanoscale advance

  2. Physics of photonic devices

    CERN Document Server

    Chuang, Shun Lien

    2009-01-01

    The most up-to-date book available on the physics of photonic devices This new edition of Physics of Photonic Devices incorporates significant advancements in the field of photonics that have occurred since publication of the first edition (Physics of Optoelectronic Devices). New topics covered include a brief history of the invention of semiconductor lasers, the Lorentz dipole method and metal plasmas, matrix optics, surface plasma waveguides, optical ring resonators, integrated electroabsorption modulator-lasers, and solar cells. It also introduces exciting new fields of research such as:

  3. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  4. A gauge device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1982-01-01

    A readily transportable device of relative light weight comprising a pair of tensioned guides for providing accurate and stable reference planes. An embodiment comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a pair of arcuate compression members. The tensioned guides provide planes of reference for measuring devices moved therealong adjacent to a component to be measured. The device is especially useful for making on-site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (author)

  5. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  6. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic radiation...

  7. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  8. Garbage Modeling for On-device Speech Recognition

    NARCIS (Netherlands)

    Van Gysel, C.; Velikovich, L.; McGraw, I.; Beaufays, F.

    2015-01-01

    User interactions with mobile devices increasingly depend on voice as a primary input modality. Due to the disadvantages of sending audio across potentially spotty network connections for speech recognition, in recent years there has been growing attention to performing recognition on-device. The

  9. Sodium aerosol recovering device

    International Nuclear Information System (INIS)

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  10. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  11. Authenticated sensor interface device

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Jody Rustyn; Poland, Richard W.

    2018-05-01

    A system and method for the secure storage and transmission of data is provided. A data aggregate device can be configured to receive secure data from a data source, such as a sensor, and encrypt the secure data using a suitable encryption technique, such as a shared private key technique, a public key encryption technique, a Diffie-Hellman key exchange technique, or other suitable encryption technique. The encrypted secure data can be provided from the data aggregate device to different remote devices over a plurality of segregated or isolated data paths. Each of the isolated data paths can include an optoisolator that is configured to provide one-way transmission of the encrypted secure data from the data aggregate device over the isolated data path. External data can be received through a secure data filter which, by validating the external data, allows for key exchange and other various adjustments from an external source.

  12. Plant abnormality inspection device

    International Nuclear Information System (INIS)

    Takenaka, Toshio.

    1990-01-01

    The present invention concerns a plant abnormality inspection device for conducting remote or automatic patrolling inspection in a plant and, more particularly, relates to such a device as capable of detecting abnormal odors. That is, the device comprises a moving device for moving to a predetermined position in the plant, a plurality of gas sensors for different kind of gases to be inspected mounted thereon, a comparator for comparing the concentration of a gas detected by the gas sensor with the normal gas concentration at the predetermined position and a judging means for judging the absence or presence of abnormality depending on the combination of the result of the comparison and deliverying a signal if the state is abnormal. As a result, a slight amount of gas responsible to odors released upon abnormality of the plant can be detected by a plurality of gas sensors for different kinds gases to rapidly and easily find abnormal portions in the plant. (I.S.)

  13. Geometry and Cloaking Devices

    Science.gov (United States)

    Ochiai, T.; Nacher, J. C.

    2011-09-01

    Recently, the application of geometry and conformal mappings to artificial materials (metamaterials) has attracted the attention in various research communities. These materials, characterized by a unique man-made structure, have unusual optical properties, which materials found in nature do not exhibit. By applying the geometry and conformal mappings theory to metamaterial science, it may be possible to realize so-called "Harry Potter cloaking device". Although such a device is still in the science fiction realm, several works have shown that by using such metamaterials it may be possible to control the direction of the electromagnetic field at will. We could then make an object hidden inside of a cloaking device. Here, we will explain how to design invisibility device using differential geometry and conformal mappings.

  14. Reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hiroto.

    1990-01-01

    The present invention concerns a reactor noise monitoring device by detecting abnormal sounds in background noises. Vibration sounds detected by accelerometers are applied to a loose parts detector. The detector generates high alarm if there are sudden impact sounds in the background noises and applies output signals to an accumulation device. If there is slight impact sounds in the vicinity of any of the accelerometers, the accumulation device accumulates the abnormal sounds assumed to be generated from an identical site while synchronizing the waveforms for all of the channels. Then, the device outputs signals in which the background noises are cancelled, as detection signals. Therefore, S/N ratio can be improved and the abnormal sounds contained in the background noises can be detected, to thereby improve the accuracy for estimating the position where the abnormal sounds are generated. (I.S.)

  15. Marine Sanitation Devices (MSDs)

    Science.gov (United States)

    Marine sanitation devices treat or retain sewage from vessels, and have performance standards set by the EPA. This page provides information on MSDs, including who must use an MSD, states' roles, types of MSDs and standards.

  16. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  17. Tokapole II device

    International Nuclear Information System (INIS)

    Sprott, J.G.

    1978-05-01

    A discussion is given of the design and operation of the Tokapole II device. The following topics are considered: physics considerations, vacuum vessel, poloidal field, ring and support design, toroidal field, vacuum system, initial results, and future plans

  18. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)

  19. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  20. Atherectomy devices: technology update

    Science.gov (United States)

    Akkus, Nuri I; Abdulbaki, Abdulrahman; Jimenez, Enrique; Tandon, Neeraj

    2015-01-01

    Atherectomy is a procedure which is performed to remove atherosclerotic plaque from diseased arteries. Atherosclerotic plaques are localized in either coronary or peripheral arterial vasculature and may have different characteristics depending on the texture of the plaque. Atherectomy has been used effectively in treatment of both coronary and peripheral arterial disease. Atherectomy devices are designed differently to either cut, shave, sand, or vaporize these plaques and have different indications. In this article, current atherectomy devices are reviewed. PMID:25565904

  1. Flexural pivot device

    International Nuclear Information System (INIS)

    Flaherty, Robert.

    1986-01-01

    A flexural pivot device or rotational actuator comprises first and sceond tubular members connected by flexural members of shape-memory-alloy. These are curved in the austenitic phase at a first temperature and after cooling to the martensitic phase are flattened. On heating one of the flexural members, it bends causing relative rotation of the tubular members. Heating of another member can produce opposite rotation. Heating is electrical or by hot gas. The device may be used in a nuclear reactor. (author)

  2. Infrared thermal annealing device

    International Nuclear Information System (INIS)

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  3. RFQ1 diagnostic devices

    International Nuclear Information System (INIS)

    Chidley, B.G.; Arbique, G.M.; de Jong, M.S.; McMichael, G.E.; Michel, W.L.; Smith, B.H.

    1991-01-01

    The diagnostic devices in use on RFQ1 will be described. They consist of a double-slit emittance-measuring unit, a 45 degree deflection energy-analysis magnet, parametric current transformers, optical beam sensors, beam-stop current monitors, and an x-ray end-point analyzer. All of these devices are able to operate up to the full output current of RFQ1 (75 mA cw at 0.6 MeV)

  4. Commercialization of microfluidic devices.

    Science.gov (United States)

    Volpatti, Lisa R; Yetisen, Ali K

    2014-07-01

    Microfluidic devices offer automation and high-throughput screening, and operate at low volumes of consumables. Although microfluidics has the potential to reduce turnaround times and costs for analytical devices, particularly in medical, veterinary, and environmental sciences, this enabling technology has had limited diffusion into consumer products. This article analyzes the microfluidics market, identifies issues, and highlights successful commercialization strategies. Addressing niche markets and establishing compatibility with existing workflows will accelerate market penetration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Direct mounted photovoltaic device with improved adhesion and method thereof

    Science.gov (United States)

    Boven, Michelle L; Keenihan, James R; Lickly, Stan; Brown, Jr., Claude; Cleereman, Robert J; Plum, Timothy C

    2014-12-23

    The present invention is premised upon a photovoltaic device suitable for directly mounting on a structure. The device includes an active portion including a photovoltaic cell assembly having a top surface portion that allows transmission of light energy to a photoactive portion of the photovoltaic device for conversion into electrical energy and a bottom surface having a bottom bonding zone; and an inactive portion immediately adjacent to and connected to the active portion, the inactive portion having a region for receiving a fastener to connect the device to the structure and having on a top surface, a top bonding zone; wherein one of the top and bottom bonding zones comprises a first bonding element and the other comprises a second bonding element, the second bonding element designed to interact with the first bonding element on a vertically overlapped adjacent photovoltaic device to bond the device to such adjacent device or to the structure.

  6. Application of high power microwave vacuum electron devices

    International Nuclear Information System (INIS)

    Ding Yaogen; Liu Pukun; Zhang Zhaochuan; Wang Yong; Shen Bin

    2011-01-01

    High power microwave vacuum electron devices can work at high frequency, high peak and average power. They have been widely used in military and civil microwave electron systems, such as radar, communication,countermeasure, TV broadcast, particle accelerators, plasma heating devices of fusion, microwave sensing and microwave heating. In scientific research, high power microwave vacuum electron devices are used mainly on high energy particle accelerator and fusion research. The devices include high peak power klystron, CW and long pulse high power klystron, multi-beam klystron,and high power gyrotron. In national economy, high power microwave vacuum electron devices are used mainly on weather and navigation radar, medical and radiation accelerator, TV broadcast and communication system. The devices include high power pulse and CW klystron, extended interaction klystron, traveling wave tube (TWT), magnetron and induced output tube (IOT). The state of art, common technology problems and trends of high power microwave vacuum electron devices are introduced in this paper. (authors)

  7. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  8. Electronic security device

    Science.gov (United States)

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  9. Organic 'Plastic' Optoelectronic Devices

    International Nuclear Information System (INIS)

    Sariciftci, N.S.

    2006-01-01

    Recent developments on conjugated polymer based photovoltaic diodes and photoactive organic field effect transistors (photOFETs) are discussed. The photophysics of such devices is based on the photoinduced charge transfer from donor type semiconducting conjugated polymers onto acceptor type conjugated polymers or acceptor molecules such as Buckminsterfullerene, C 6 0. Potentially interesting applications include sensitization of the photoconductivity and photovoltaic phenomena as well as photoresponsive organic field effect transistors (photOFETs). Furthermore, organic polymeric/inorganic nanoparticle based 'hybrid' solar cells will be discussed. This talk gives an overview of materials' aspect, charge-transport, and device physics of organic diodes and field-effect transistors. Furthermore, due to the compatibility of carbon/hydrogen based organic semiconductors with organic biomolecules and living cells there can be a great opportunity to integrate such organic semiconductor devices (biOFETs) with the living organisms. In general the largely independent bio/lifesciences and information technology of today, can be thus bridged in an advanced cybernetic approach using organic semiconductor devices embedded in bio-lifesciences. This field of bio-organic electronic devices is proposed to be an important mission of organic semiconductor devices

  10. Evaluating imaging devices

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1977-01-01

    The performance of any imaging device depends on two principal factors inherent to the device, namely, plane sensitivity and spatial resolution. These factors may be defined as follows: plane sensitivity is the counts per second recorded by the imaging device for each disintegration per second per square centimeter occurring within a plane sheet of radioactivity. Spatial resolution may be defined as the fidelity with which the imaging device reproduces the activity distribution of an object in the image plane. In all imaging devices, a trade-off exists between these two parameters; that is, as sensitivity improves, spatial resolution is degraded, and vice versa. Therefore, to fully evaluate an imaging system a technique should be selected that measures both parameters and reflects the trade-off between the two. In addition, the method should approximate the clinical problem, namely, the detection of a focal lesion within an activity distribution. Several methods have been described to evaluate nuclear imaging devices. The more common techniques include the use of organ phantoms, bar phantoms, line-spread functions, modulation transfer functions, contrast efficiency functions, and performance index functions. Each of these techniques is briefly described in this chapter, and their advantages and disadvantages are discussed. In addition, a phantom that can be used to simply and completely measure overall imaging system performance is described

  11. Electronic security device

    International Nuclear Information System (INIS)

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-01-01

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  12. A pneumatic muscle hand therapy device.

    Science.gov (United States)

    Koeneman, E J; Schultz, R S; Wolf, S L; Herring, D E; Koeneman, J B

    2004-01-01

    Intensive repetitive therapy improves function and quality of life for stroke patients. Intense therapies to overcome upper extremity impairment are beneficial, however, they are expensive because, in part, they rely on individualized interaction between the patient and rehabilitation specialist. The development of a pneumatic muscle driven hand therapy device, the Mentortrade mark, reinforces the need for volitional activation of joint movement while concurrently offering knowledge of results about range of motion, muscle activity or resistance to movement. The device is well tolerated and has received favorable comments from stroke survivors, their caregivers, and therapists.

  13. Dark patterns in proxemic interactions

    DEFF Research Database (Denmark)

    Greenberg, Saul; Boring, Sebastian; Vermeulen, Jo

    2014-01-01

    to better facilitate seamless and natural interactions. To do so, both people and devices are tracked to determine their spatial relationships. While interest in proxemic interactions has increased over the last few years, it also has a dark side: knowledge of proxemics may (and likely will) be easily...... exploited to the detriment of the user. In this paper, we offer a critical perspective on proxemic interactions in the form of dark patterns: ways proxemic interactions can be misused. We discuss a series of these patterns and describe how they apply to these types of interactions. In addition, we identify...

  14. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min

    2017-01-01

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured

  15. [Anesthesia simulators and training devices].

    Science.gov (United States)

    Hartmannsgruber, M; Good, M; Carovano, R; Lampotang, S; Gravenstein, J S

    1993-07-01

    Simulators and training devices are used extensively by educators in 'high-tech' occupations, especially those requiring an understanding of complex systems and co-ordinated psychomotor skills. Because of advances in computer technology, anaesthetised patients can now be realistically simulated. This paper describes several training devices and a simulator currently being employed in the training of anaesthesia personnel at the University of Florida. This Gainesville Anesthesia Simulator (GAS) comprises a patient mannequin, anaesthesia gas machine, and a full set of normally operating monitoring instruments. The patient can spontaneously breathe, has audible heart and breath sounds, and palpable pulses. The mannequin contains a sophisticated lung model that consumes and eliminates gas according to physiological principles. Interconnected computers controlling the physical signs of the mannequin enable the presentation of a multitude of clinical signs. In addition, the anaesthesia machine, which is functionally intact, has hidden fault activators to challenge the user to correct equipment malfunctions. Concealed sensors monitor the users' actions and responses. A robust data acquisition and control system and a user-friendly scripting language for programming simulation scenarios are key features of GAS and make this system applicable for the training of both the beginning resident and the experienced practitioner. GAS enhances clinical education in anaesthesia by providing a non-threatening environment that fosters learning by doing. Exercises with the simulator are supported by sessions on a number of training devices. These present theoretical and practical interactive courses on the anaesthesia machine and on monitors. An extensive system, for example, introduces the student to the physics and clinical application of transoesophageal echocardiography.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. What Do We Need to Protect, at All Costs, During the 21st Century? Reflections From a Curated, Interactive Co-Created Intellectual Jazz Performance.

    Science.gov (United States)

    Jadad, Alejandro R; Davis, Dave

    2016-01-01

    The question that forms the title of this article, "What do we need to protect, at all costs, during the 21st century?," speaks to the sizable changes in health care systems and settings that surround the continuing professional development (CPD) provider, and the need to establish a core set of principles and practices as the field moves forward from both theoretical and practical aspects. It also provided the focus for one of the five keynote lectures presented during the 2016 World Congress on Continuing Professional Development. As the planners of this keynote session, we sought to evoke answers to the question, not from the speaker, but from the audience itself, a process enabled by a highly engaging presentation style and powered by interactive digital technologies. Further, we believed that the session would not directly lead to suggestions to improve the theory and practice of CPD, but rather to create the biopsychosocial context-a sort of platform-on which such discussions can occur.

  17. Flaw detection device

    International Nuclear Information System (INIS)

    Sasahara, Toshihiko

    1998-01-01

    The present invention provides a device for detecting welded portions of a reactor pressure vessel. Namely, the device of the present invention comprises (1) a casing to be disposed on the surface to be detected, (2) a probe driving means loaded to the casing, (3) a probe driven along the surface to be detected and (4) a pressure reduction means for keeping the hollow portion in the casing to an evacuated atmosphere. The casing comprises a flexible suction edge to be tightly in contact with the surface to be tested for maintaining the air tight state, (6) a guide wheel for moving the casing along the surface to be tested and (7) a handle for performing transferring operation. The flaw detection device thus constituted has following features. The working efficiency upon conducting detection is improved. The influence of the weight of the device on the detection is small. The device can be applied on the surface of a nonmagnetic material. The efficiency for the flaw detection can be improved. (I.S.)

  18. Electrical apparatus lockout device

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, R.

    1999-10-12

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards.

  19. Operation training aid device

    International Nuclear Information System (INIS)

    Yoshimura, Sadanori.

    1994-01-01

    The device of the present invention evaluates the propriety of an operation which is conducted optionally by a trainee depending on the state of the plant, analyzes the cause of an operation error and aids the preparation of training policy and teaching materials based on the results of the evaluation and the analysis. Namely, an operation data collection device collects operation data for the plant operation conducted by the trainee and the state of the plant during the operation. Since an operation evaluation device evaluates the plant operation in a short period of time based on the evaluation criteria of an operation evaluation knowledge base, an operation error is never overlooked. Accordingly, uniform and highly reliable operation training at definite evaluation criteria can be obtained. In addition, an error-cause analyzing device and a training policy knowledge base analyze the cause of an error inherent to each of the trainee, and it is recorded systematically independently on every trainees. Since a training policy guide device retrieves and presents an operation error and a cause of the error, there can be prepared a training policy incorporating training with respect to the operation error that each of the trainee tends to commit. (I.S.)

  20. Reactor container cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Koji; Kinoshita, Shoichiro

    1995-11-10

    The device of the present invention efficiently lowers pressure and temperature in a reactor container upon occurrence of a severe accident in a BWR-type reactor and can cool the inside of the container for a long period of time. That is, (1) pipelines on the side of an exhaustion tower of a filter portion in a filter bent device of the reactor container are in communication with pipelines on the side of a steam inlet of a static container cooling device by way of horizontal pipelines, (2) a back flow check valve is disposed to horizontal pipelines, (3) a steam discharge valve for a pressure vessel is disposed closer to the reactor container than the joint portion between the pipelines on the side of the steam inlet and the horizontal pipelines. Upon occurrence of a severe accident, when the pressure vessel should be ruptured and steams containing aerosol in the reactor core should be filled in the reactor container, the inlet valve of the static container cooling device is closed. Steams are flown into the filter bent device of the reactor container, where the aerosols can be removed. (I.S.).

  1. Loose part monitoring device

    International Nuclear Information System (INIS)

    Nomura, Hiroshi.

    1992-01-01

    The device of the present invention estimates a place where loose parts occur and structural components as the loose parts in a fluid flow channel of a reactor device, to provide information thereof to a plant operator. That is, the device of the present invention comprises (1) a plurality of detectors disposed to each of equipments constituting fluid channels, (2) an abnormal sound sensing device for sensing signals from the detectors, (3) an estimation section for estimating the place where the loose parts occur and the structural components thereof based on the signals sensed by the abnormal sound sensing section, (4) a memory section for storing data of the plant structure necessary for the estimation, and (5) a display section for displaying the result of the estimation. In such a device, the position where the loose parts collide against the plant structural component and the energy thereof are estimated. The dropping path of the loose parts is estimated from the estimation position. Parts to be loose parts in the path are listed up. The parts on the list is selected based on the estimated energy thereby enabling to determine the loose parts. (I.S.)

  2. Electrical apparatus lockout device

    International Nuclear Information System (INIS)

    Gonzales, R.

    1999-01-01

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards

  3. Nuclear reactor monitoring device

    International Nuclear Information System (INIS)

    Mihashi, Ishi; Honma, Hitoshi.

    1993-01-01

    The monitoring device of the present invention comprises a reactor core/reactor system data measuring and controlling device, a radioactivity concentration calculation device for activated coolants for calculating a radioactivity concentration of activated coolants in a main steam and reactor water by using an appropriate physical model, a radioactivity concentration correlation and comparison device for activated coolants for comparing correlationship with a radiation dose and an abnormality alarm device. Since radioactivity of activated primary coolants is monitored at each of positions in the reactor system and occurrence of leakage and the amount thereof from a primary circuit to a secondary circuit is monitored if the reactor has secondary circuit, integrity of the reactor system can be ensured and an abnormality can be detected rapidly. Further, radioactivity concentration of activated primary circuit coolants, represented by 16 N or 15 C, is always monitored at each of positions of PWR primary circuits. When a heat transfer pipe is ruptured in a steam generator, leakage of primary circuit coolants is detected rapidly, as well as the amount of the leakage can be informed. (N.H.)

  4. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  5. Microfluidics and Lab-on-a-Chip Devices

    DEFF Research Database (Denmark)

    Castillo, Jaime

    2015-01-01

    The rapid advances in microfabrication and nanofabrication in combination with the synthesis and discovery of new materials have propelled the drive to develop new technological devices such as smartphones, personal and tablet computers. These devices have changed the way humankind interacts......TAS technologies need to join forces with those behind the new communication devices which provide sources of power, detection and data transmission complementing the features that lab-on-a-chip and microTAS platforms can offer. An increasing number of microfluidic-based devices, developed both in small start...

  6. Device for overlapping of a column of pump compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Akhmerov, M.N.; Asadullin, Kh.F.; Prokopov, O.I.

    1980-02-16

    A device is proposed for automatic overlapping of pump compressor pipes of gushing petroleum and gas wells when losses occur near the well. The objective of the invention is to increase efficiency of the overlapping of the pipe column by recharging the device directly at the hole without disassembling the head equipment. This objective is achieved as follows. The device is equipped with elastic spacers located in the channels of a ring. They are mounted with the possibility of interaction with ball catches. A drawing and description of the device are given.

  7. Fragment capture device

    Science.gov (United States)

    Payne, Lloyd R.; Cole, David L.

    2010-03-30

    A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.

  8. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  9. Nonimaging radiant energy device

    Science.gov (United States)

    Winston, Roland; Ning, Xiaohui

    1993-01-01

    A nonimaging radiant energy device may include a hyperbolically shaped reflective element with a radiant energy inlet and a radiant energy outlet. A convex lens is provided at the radiant energy inlet and a concave lens is provided at the radiant energy outlet. Due to the provision of the lenses and the shape of the walls of the reflective element, the radiant energy incident at the radiant energy inlet within a predetermined angle of acceptance is emitted from the radiant energy outlet exclusively within an acute exit angle. In another embodiment, the radiant energy device may include two interconnected hyperbolically shaped reflective elements with a respective convex lens being provided at each aperture of the device.

  10. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  11. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Sano, Yuji.

    1988-01-01

    Purpose: To easily and reliably detect the consumption of a sputtered cathode in a radioactive gas storage device using ion injection method. Constitution: Inert gases are sealed to the inside of a cathode. As the device is operated, the cathode is consumed and, if it is scraped to some extent, inert gases in the cathode gases are blown out to increase the inner pressure of the device. The pressure elevation is detected by a pressure detector connected with a gas introduction pipe or discharge pipe. Further, since the discharge current in the inside is increased along with the elevation of the pressure, it is possible to detect the increase of the electrical current. In this way, the consumption of the cathode can be recognized by detecting the elevation in the pressure or increase in the current. (Ikeda, J.)

  12. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  13. Steam cleaning device

    International Nuclear Information System (INIS)

    Karaki, Mikio; Muraoka, Shoichi.

    1985-01-01

    Purpose: To clean complicated and long objects to be cleaned having a structure like that of nuclear reactor fuel assembly. Constitution: Steams are blown from the bottom of a fuel assembly and soon condensated initially at the bottom of a vertical water tank due to water filled therein. Then, since water in the tank is warmed nearly to the saturation temperature, purified water is supplied from a injection device below to the injection device above the water tank on every device. In this way, since purified water is sprayed successively from below to above and steams are condensated in each of the places, the entire fuel assembly elongated in the vertical direction can be cleaned completely. Water in the reservoir goes upward like the steam flow and is drained together with the eliminated contaminations through an overflow pipe. After the cleaning has been completed, a main steam valve is closed and the drain valve is opened to drain water. (Kawakami, Y.)

  14. Laser device and method

    International Nuclear Information System (INIS)

    Myers, J.D.

    1986-01-01

    A method is described of treatment of opacity of the lens of an eye resulting from foreign matter at the back surface of the eye lens within the vitreous fluid body of the eye with a passively Q-switched laser device. The method consists of: (a) generating a single lasing pulse emitted from the laser device focused within the eye vitreous fluid body, spaced from the lens back surface, creating a microplasma dot in the vitreous fluid body (b) then increasing the frequency of the lasing pulses emitted from the lasing device having a frequency greater than the life of the microplasma to generate an elongated lasing plasma within the eye vitreous fluid moving toward the lens back surface, until the elongated lasing plasma contacts and destroys the foreign matter

  15. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  16. Asphaltene based photovoltaic devices

    Science.gov (United States)

    Chianelli, Russell R.; Castillo, Karina; Gupta, Vipin; Qudah, Ali M.; Torres, Brenda; Abujnah, Rajib E.

    2016-03-22

    Photovoltaic devices and methods of making the same, are disclosed herein. The cell comprises a photovoltaic device that comprises a first electrically conductive layer comprising a photo-sensitized electrode; at least one photoelectrochemical layer comprising metal-oxide particles, an electrolyte solution comprising at least one asphaltene fraction, wherein the metal-oxide particles are optionally dispersed in a surfactant; and a second electrically conductive layer comprising a counter-electrode, wherein the second electrically conductive layer comprises one or more conductive elements comprising carbon, graphite, soot, carbon allotropes or any combinations thereof.

  17. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1968-01-01

    Electronic Devices and Circuits, Volume 1 deals with the design and applications of electronic devices and circuits such as passive components, diodes, triodes and transistors, rectification and power supplies, amplifying circuits, electronic instruments, and oscillators. These topics are supported with introductory network theory and physics. This volume is comprised of nine chapters and begins by explaining the operation of resistive, inductive, and capacitive elements in direct and alternating current circuits. The theory for some of the expressions quoted in later chapters is presented. Th

  18. INLET STRATIFICATION DEVICE

    DEFF Research Database (Denmark)

    2006-01-01

    An inlet stratification device (5) for a circuit circulating a fluid through a tank (1 ) and for providing and maintaining stratification of the fluid in the tank (1 ). The stratification de- vice (5) is arranged vertically in the tank (1) and comprises an inlet pipe (6) being at least partially...... formed of a flexible porous material and having an inlet (19) and outlets formed of the pores of the porous material. The stratification device (5) further comprises at least one outer pipe (7) surrounding the inlet pipe (6) in spaced relationship thereto and being at least partially formed of a porous...

  19. Precision alignment device

    Science.gov (United States)

    Jones, N.E.

    1988-03-10

    Apparatus for providing automatic alignment of beam devices having an associated structure for directing, collimating, focusing, reflecting, or otherwise modifying the main beam. A reference laser is attached to the structure enclosing the main beam producing apparatus and produces a reference beam substantially parallel to the main beam. Detector modules containing optical switching devices and optical detectors are positioned in the path of the reference beam and are effective to produce an electrical output indicative of the alignment of the main beam. This electrical output drives servomotor operated adjustment screws to adjust the position of elements of the structure associated with the main beam to maintain alignment of the main beam. 5 figs.

  20. Microfluidic Cell Culture Device

    Science.gov (United States)

    Takayama, Shuichi (Inventor); Cabrera, Lourdes Marcella (Inventor); Heo, Yun Seok (Inventor); Smith, Gary Daniel (Inventor)

    2014-01-01

    Microfluidic devices for cell culturing and methods for using the same are disclosed. One device includes a substrate and membrane. The substrate includes a reservoir in fluid communication with a passage. A bio-compatible fluid may be added to the reservoir and passage. The reservoir is configured to receive and retain at least a portion of a cell mass. The membrane acts as a barrier to evaporation of the bio-compatible fluid from the passage. A cover fluid may be added to cover the bio-compatible fluid to prevent evaporation of the bio-compatible fluid.

  1. Pipe closing device

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    The closing device closes the upper end of a support tube for monitoring samples. It meshes with the upper connecting piece of the monitorung sample capsule, and loads the capsule within the bore of the support tube, so that it is fixed but can be released. The closing device consists of an interlocking component with a chamber and several ratchets which hang down. The interlocking component surrounds the actuating component for positioning the ratchets. The interlocking and actuating components are movable axially relative to each other. (DG) [de

  2. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  3. Simulation of semiconductor devices

    International Nuclear Information System (INIS)

    Oriato, D.

    2001-09-01

    In this thesis a drift diffusion model coupled with self-consistent solutions of Poisson's and Schroedinger's equations, is developed and used to investigate the operation of Gunn diodes and GaN-based LEDs. The model also includes parameters derived from Monte Carlo calculations of the simulated devices. In this way the characteristics of a Monte Carlo approach and of a quantum solver are built into a fast and flexible drift-diffusion model that can be used for testing a large number of heterostructure designs in a time-effective way. The full model and its numerical implementation are described in chapter 2. In chapter 3 the theory of Gunn diodes is presented. A basic model of the dynamics of domain formation and domain transport is described with particular regard to accumulation and dipole domains. Several modes of operation of the Gunn device are described, varying from the resonance mode to the quenched mode. Details about transferred electron devices and negative differential resistance in semiconductor materials are given. In chapter 4 results from the simulation of a simple conventional gunn device confirm the importance of the doping condition at the cathode. Accumulation or dipole domains are achieved respectively with high and low doping densities. The limits of a conventional Gunn diode are explained and solved by introducing the heterostructure Gunn diode. This new design consists of a conventional GaAs transit region coupled with an electron launcher at the cathode, made using an AIGaAs heterostructure step. Simulations show the importance of the insertion of a thin highly-doped layer between the transit region and the electron launcher in order to improve device operation. Chapter 5 is an introduction to Ill-nitrides, in particular GaN and its alloy ln-GaN. We outline the discrepancy in the elastic and piezoelectric parameters found in the literature. Strain, dislocations and piezoelectricity are presented as the main features of a InGaN/GaN system

  4. Nanoscale memory devices

    International Nuclear Information System (INIS)

    Chung, Andy; Deen, Jamal; Lee, Jeong-Soo; Meyyappan, M

    2010-01-01

    This article reviews the current status and future prospects for the use of nanomaterials and devices in memory technology. First, the status and continuing scaling trends of the flash memory are discussed. Then, a detailed discussion on technologies trying to replace flash in the near-term is provided. This includes phase change random access memory, Fe random access memory and magnetic random access memory. The long-term nanotechnology prospects for memory devices include carbon-nanotube-based memory, molecular electronics and memristors based on resistive materials such as TiO 2 . (topical review)

  5. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  6. Device for removing fur

    International Nuclear Information System (INIS)

    Hanawa, Minoru; Nakagawa, Takao; Sakuma, Toyoo; Yonemura, Eizo.

    1976-01-01

    Purpose: To effectively remove fur adhered to fuel rods and to increase working efficiency without use of a lengthy hose. Constitution: In the fur removing device of the present invention, brushes rotated by gears are provided within a casing so that fur adhered to the fuel rods are removed by the brushes and water is rotatably moved by blades housed therein to outwardly blow fur floating in water by means of a centrifugal force. Then, the fur is filtered by a filter outwardly provided. In this way, the fur may be collected within the device to avoid contamination to others. (Kamimura, M.)

  7. Device-Centric Monitoring for Mobile Device Management

    OpenAIRE

    Chircop, Luke; Colombo, Christian; Pace, Gordon J.

    2016-01-01

    The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centri...

  8. Towards Generic Interaction Styles for Product Design

    DEFF Research Database (Denmark)

    Buur, Jacob; Stienstra, Marcelle

    2008-01-01

    a wider range of interactive products. In this paper we report on five years of continued research into interaction styles for telephones, kitchen equipment, HiFi products and medical devices, and we show how it is indeed possible and beneficial to formulate a set of generic interaction styles....

  9. Materials for electrochemical device safety

    Science.gov (United States)

    Vissers, Daniel R.; Amine, Khalil; Thackeray, Michael M.; Kahaian, Arthur J.; Johnson, Christopher S.

    2015-04-07

    An electrochemical device includes a thermally-triggered intumescent material or a gas-triggered intumescent material. Such devices prevent or minimize short circuits in a device that could lead to thermal run-away. Such devices may include batteries or supercapacitors.

  10. Learning English Using Children's Stories in Mobile Devices

    Science.gov (United States)

    Cavus, Nadire; Ibrahim, Dogan

    2017-01-01

    The topic of this paper is to describe the development of an interactive application that can be used in teaching English as a second language using children's stories in mobile devices. The aim of this experimental study has been to find out the potential of using the developed interactive mobile application in improving the learning skills such…

  11. Device configuration-management system

    International Nuclear Information System (INIS)

    Nowell, D.M.

    1981-01-01

    The Fusion Chamber System, a major component of the Magnetic Fusion Test Facility, contains several hundred devices which report status to the Supervisory Control and Diagnostic System for control and monitoring purposes. To manage the large number of diversity of devices represented, a device configuration management system was required and developed. Key components of this software tool include the MFTF Data Base; a configuration editor; and a tree structure defining the relationships between the subsystem devices. This paper will describe how the configuration system easily accomodates recognizing new devices, restructuring existing devices, and modifying device profile information

  12. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  13. Nano devices and sensors

    CERN Document Server

    Liaw, Shien-Kuei; Chung, Yung-Hui

    2016-01-01

    This volume on semiconductor devices focuses on such topics as nano-imprinting, lithography, nanowire charge-trapping, thermo-stability in nanowires, nano-electrodes, and voltage and materials used for fabricating and improving electrical characteristics of nano-materials.

  14. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2005-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  15. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2000-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  16. Criticality alarm device

    International Nuclear Information System (INIS)

    Kasai, Kenji.

    1994-01-01

    The device of the present invention is utilized, for example, to a reprocessing facility for storing and processing nuclear fuels and measures and controls the nuclear fuel assembly system so as not to exceed criticality. That is, a conventional criticality alarm device applies a predetermined processing to neutron fluxes generated from a nuclear fuel assembly system containing nuclear fuels and outputs an alarm. The device of the present invention comprises (1) a neutron flux supply source for increasing and decreasing neutron fluxes periodically and supplying them to nuclear fuel assemblies, (2) a detector for detecting neutron fluxes in the nuclear fuel assemblies, (3) a critical state judging section for judging the critical state of the nuclear fuel assemblies based on the periodically changing signals obtained from the detector (2) and (4) an alarm section for outputting criticality alarms depending on the result of the judgement. The device of the present invention can accurately recognize the critical state of the nuclear fuel assembly system and can forecast reaching of the nuclear fuel assembly to criticality or prompt neutron critical state. (I.S.)

  17. Static memory devices

    NARCIS (Netherlands)

    2012-01-01

    A semiconductor memory device includes n-wells (22) and p-wells (24) used to make up a plurality of memory cell elements (40). The n-wells (22) and p-5 wells (24) can be back-biased to improve reading and writing performance. One of the n-wells and p-wells can be globally biased while the other one

  18. Programmable ubiquitous telerobotic devices

    Science.gov (United States)

    Doherty, Michael; Greene, Matthew; Keaton, David; Och, Christian; Seidl, Matthew L.; Waite, William; Zorn, Benjamin G.

    1997-12-01

    We are investigating a field of research that we call ubiquitous telepresence, which involves the design and implementation of low-cost robotic devices that can be programmed and operated from anywhere on the Internet. These devices, which we call ubots, can be used for academic purposes (e.g., a biologist could remote conduct a population survey), commercial purposes (e.g., a house could be shown remotely by a real-estate agent), and for recreation and education (e.g., someone could tour a museum remotely). We anticipate that such devices will become increasingly common due to recent changes in hardware and software technology. In particular, current hardware technology enables such devices to be constructed very cheaply (less than $500), and current software and network technology allows highly portable code to be written and downloaded across the Internet. In this paper, we present our prototype system architecture, and the ubot implementation we have constructed based on it. The hardware technology we use is the handy board, a 6811-based controller board with digital and analog inputs and outputs. Our software includes a network layer based on TCP/IP and software layers written in Java. Our software enables users across the Internet to program the behavior of the vehicle and to receive image feedback from a camera mounted on it.

  19. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  20. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  1. Road-Cleaning Device

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    Roadways are literally soaked with petrochemical byproducts, oils, gasoline, and other volatile substances that eventually run off into sewers and end up in rivers, waterways, and other undesirable places. Can the roads be cleaned of these wastes, with their proper disposal? Can vehicles, robots, or other devices be designed that could be driven…

  2. Loading device for incinerator

    International Nuclear Information System (INIS)

    Hempelmann, W.

    1983-01-01

    An incinerator for radioactive waste is described. Heat radiation from the incinerator into the loading device is reduced by the design of the slider with a ceramic plate and the conical widening of the pot, and also by fixing a metal plate between the pot and the floor. (PW) [de

  3. Surface Acoustic Wave Devices

    DEFF Research Database (Denmark)

    Dühring, Maria Bayard

    The work of this project is concerned with the simulation of surface acoustic waves (SAW) and topology optimization of SAW devices. SAWs are elastic vibrations that propagate along a material surface and are extensively used in electromechanical filters and resonators in telecommunication. A new...

  4. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  5. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  6. Medical device development.

    Science.gov (United States)

    Panescu, Dorin

    2009-01-01

    The development of a successful medical product requires not only engineering design efforts, but also clinical, regulatory, marketing and business expertise. This paper reviews items related to the process of designing medical devices. It discusses the steps required to take a medical product idea from concept, through development, verification and validation, regulatory approvals and market release.

  7. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  8. Laser decontamination device

    International Nuclear Information System (INIS)

    Michishita, Shizuo; Akagawa, Katsuhiko.

    1997-01-01

    One end of an optical fiber inserted into an inner cylinder is opposed to a wall surface to be decontaminated, and an opened top end of an intermediate cylinder circumferentially surrounding the inner cylinder is tightly in contact with the wall surface to be decontaminated, an open end of an outer cylinder circumferentially surrounding the intermediate cylinder is tightly in contact with the wall surface to be decontaminated. Dust removing holes are perforated in the vicinity of the top end of the intermediate cylinder while being in communication with the inside and the outside of the intermediate cylinder, and one end of an air supply tube is in communication with the space between the outer circumferential surface of the inner cylinder and the inner circumferential surface of the intermediate cylinder. The other end of the air supply tube is connected to an air supply device, one end of a sucking tube is in communication with the space between the outer circumferential surface of the intermediate cylinder and the inner circumferential surface of the outer cylinder, the other end of the sucking tube is connected to a sucking device, and the other end of the optical fiber is connected to a laser generation device. The laser generation device is operated while determining the air sucking amount increased than the air supply amount, the materials deposited on the wall surface are crushed and peeled off, and the peeled off materials are transferred by air flow to a filter and collected. (N.H.)

  9. Rotary combustion device

    NARCIS (Netherlands)

    2008-01-01

    Rotary combustion device (1) with rotary combustion chamber (4). Specific measures are taken to provide ignition of a combustible mixture. It is proposed that a hollow tube be provided coaxially with the axis of rotation (6), so that a small part of the mixture is guided into the combustion chamber.

  10. Devic's Disease (Neuromyelitis optical)

    International Nuclear Information System (INIS)

    Pinzon, Alfredo; Echeverry, Tatiana; Rodriguez, Aida Bibiana

    2010-01-01

    We present a case report about a young woman initially treated as having multiple sclerosis, who relapsed with serious visual impairment. Devic's disease is a demyelinating disorder that presents as transverse myelitis associated with optic neuritis, typically bilateral. Multiple sclerosis is in fact the main differential diagnosis

  11. The ''ATOS'' experimental device

    International Nuclear Information System (INIS)

    Belyaev, V.A.; Dorovskij, A.P.; Dubrovin, M.M.; Khlopkin, A.N.

    1980-08-01

    This paper contains a brief description of the ATOS experimental device at the I.V. Kurchatov Institute, Moscow, USSR, which has been designed in accordance with the merged beam principle to investigate collisions between heavy atomic particles and multiply-charged ions of impurity elements - following the programme of the Joint IFRC/INDC Subcommittee on Atomic and Molecular Data for Fusion

  12. Liver Cell Culture Devices

    NARCIS (Netherlands)

    Andria, B.; Bracco, A.; Cirino, G.; Chamuleau, R. A. F. M.

    2010-01-01

    In the last 15 years many different liver cell culture devices, consisting of functional liver cells and artificial materials, have been developed. They have been devised for numerous different applications, such as temporary organ replacement (a bridge to liver transplantation or native liver

  13. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared...

  14. Single Value Devices

    NARCIS (Netherlands)

    Mader, Angelika H.; Dertien, Edwin Christian; Reidsma, Dennis

    2011-01-01

    We live in a world of continuous information overflow, but the quality of information and communication is suffering. Single value devices contribute to the information and communication quality by fo- cussing on one explicit, relevant piece of information. The information is decoupled from a

  15. Power generating device

    Energy Technology Data Exchange (ETDEWEB)

    Onodera, Toshihiro

    1989-05-02

    The existing power generating device consisting of static components only lacks effective measures to utilize solar energy and maintain power generation, hence it is inevitable to make the device much larger and more complicated in order to utilize it as the primary power source for artificial satellites. In view of the above, in order to offer a power generating device useful for the primary power source for satellites which is simple and can keep power generation by solar energy, this invention proposes a power generating device composed of the following elements: (1) a rectangular parallelopiped No. II superconductor plate; (2) a measure to apply a magnetic field to one face of the above superconductor plate; (3) a measure to provide a temperature difference within the range between the starting temperature and the critical temperature of superconductivity to a pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure; (4) a measure to provide an electrode on each of the other pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure and form a closed circuit by connecting the each electrode above to each of a pair of electrodes of the load respectively; and (5) a switching measure which is installed in the closed circuit prepared by the above measure and shuts off the closed circuit when the direction of the electric current running the above closed circuit is reversed. 6 figs.

  16. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  17. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  18. Inhalation drug delivery devices: technology update

    Directory of Open Access Journals (Sweden)

    Ibrahim M

    2015-02-01

    Full Text Available Mariam Ibrahim, Rahul Verma, Lucila Garcia-ContrerasDepartment of Pharmaceutical Sciences, College of Pharmacy, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USAAbstract: The pulmonary route of administration has proven to be effective in local and systemic delivery of miscellaneous drugs and biopharmaceuticals to treat pulmonary and non-pulmonary diseases. A successful pulmonary administration requires a harmonic interaction between the drug formulation, the inhaler device, and the patient. However, the biggest single problem that accounts for the lack of desired effect or adverse outcomes is the incorrect use of the device due to lack of training in how to use the device or how to coordinate actuation and aerosol inhalation. This review summarizes the structural and mechanical features of aerosol delivery devices with respect to mechanisms of aerosol generation, their use with different formulations, and their advantages and limitations. A technological update of the current state-of-the-art designs proposed to overcome current challenges of existing devices is also provided.Keywords: pulmonary delivery, asthma, nebulizers, metered dose inhaler, dry powder inhaler

  19. A Phenomenological Study of Middle School Students' Self-Regulated Learning with Mobile Devices

    Science.gov (United States)

    Doud, Janet M.

    2016-01-01

    An integral part of 21st century learning for middle school students included the daily use of mobile device technology. The problem with mobile devices, full of their interactive interfaces, was how did the student personally discover which features and tools within the device will best benefit the student's style and needs, thus enhancing…

  20. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... Device In the preamble to the proposed rule (44 FR 13369; March 9, 1979), the Cardiovascular Device... Bypass Grafting: A Propensity Score Analysis,'' Interactive Cardiovascular and Thoracic Surgery, vol. 9...

  1. Evaluating and Predicting Patient Safety for Medical Devices With Integral Information Technology

    Science.gov (United States)

    2005-01-01

    323 Evaluating and Predicting Patient Safety for Medical Devices with Integral Information Technology Jiajie Zhang, Vimla L. Patel, Todd R...errors are due to inappropriate designs for user interactions, rather than mechanical failures. Evaluating and predicting patient safety in medical ...the users on the identified trouble spots in the devices. We developed two methods for evaluating and predicting patient safety in medical devices

  2. Internal inspection devices

    International Nuclear Information System (INIS)

    1982-01-01

    In order to evaluate the possibilities and limits of using specific endoscopes, the design and performance of rigid and flexible endoscopes are studied. The results show on the one hand the physical conditions setting a limit to the applicability of a certain device, and on the other indicate possible ways of improving and modifying given devices so as to adapt them to the special requirements of current testing standards. Based on theoretical and practical experience, proposals for improvements are made. For rigid endoscopes, e.g., additional equipment has been developed and is described in detail, allowing hitherto existing problems to be solved, thus enlarging the range of employment and enhancing and improving the information to be gained by testing using endoscopes. (orig./RW) [de

  3. Fractional-order devices

    CERN Document Server

    Biswas, Karabi; Caponetto, Riccardo; Mendes Lopes, António; Tenreiro Machado, José António

    2017-01-01

    This book focuses on two specific areas related to fractional order systems – the realization of physical devices characterized by non-integer order impedance, usually called fractional-order elements (FOEs); and the characterization of vegetable tissues via electrical impedance spectroscopy (EIS) – and provides readers with new tools for designing new types of integrated circuits. The majority of the book addresses FOEs. The interest in these topics is related to the need to produce “analogue” electronic devices characterized by non-integer order impedance, and to the characterization of natural phenomena, which are systems with memory or aftereffects and for which the fractional-order calculus tool is the ideal choice for analysis. FOEs represent the building blocks for designing and realizing analogue integrated electronic circuits, which the authors believe hold the potential for a wealth of mass-market applications. The freedom to choose either an integer- or non-integer-order analogue integrator...

  4. Radiation detection device

    International Nuclear Information System (INIS)

    Peschmann, Kristian.

    1982-01-01

    A radiation detector suitable for use in computer tomography device has an ionization chamber which comprises a high voltage electrode, a collector electrode, a high voltage source having two terminals, one connected to the high voltage electrode, current measuring means having two terminals, one connected to the high voltage source and the other to the collector electrode, and an auxilliary electrode near and parallel to the entrance window of the device, having one adjacent to the high voltage electrode and the other adjacent but not connected to the collector electrode. The auxilliary electrode is connected to the high voltage source. In this way the electric field between the high voltage and collector electrodes is made homogeneous in the vicinity of the auxilliary electrode, improving the measuring speed of the detector

  5. Atherectomy devices: technology update

    Directory of Open Access Journals (Sweden)

    Akkus NI

    2014-12-01

    Full Text Available Nuri I Akkus,1 Abdulrahman Abdulbaki,1 Enrique Jimenez,2 Neeraj Tandon2 1Department of Cardiology, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA; 2Department of Cardiology, Overton Brooks VA Medical Center, Shreveport, LA, USA Abstract: Atherectomy is a procedure which is performed to remove atherosclerotic plaque from diseased arteries. Atherosclerotic plaques are localized in either coronary or peripheral arterial vasculature and may have different characteristics depending on the texture of the plaque. Atherectomy has been used effectively in treatment of both coronary and peripheral arterial disease. Atherectomy devices are designed differently to either cut, shave, sand, or vaporize these plaques and have different indications. In this article, current atherectomy devices are reviewed. Keywords: coronary artery disease, peripheral arterial disease

  6. Support and maneuvering device

    Science.gov (United States)

    Wood, R.L.

    1987-03-23

    A support and maneuvering device includes an elongated flexible inflatable enclosure having a fixed end and a movable end. The movable end is collapsible toward the fixed end to a contracted position when the enclosure is in a noninflated condition. Upon inflation, the movable end is movable away from the fixed end to an extended position. The movable end includes means for mounting an article such as a solar reflector thereon. The device also includes a plurality of position controlling means disposed about the movable end to effect adjusting movement of portions thereof by predetermined amounts and for controlling an angle at which the article disposed at the movable end is oriented. The plurality of position controlling means limits a suitable number degrees of freedom of the movable end for transmitting a steering motion thereto and for controlling the position thereof. 9 figs.

  7. Microelectromechanical reprogrammable logic device

    Science.gov (United States)

    Hafiz, M. A. A.; Kosuru, L.; Younis, M. I.

    2016-01-01

    In modern computing, the Boolean logic operations are set by interconnect schemes between the transistors. As the miniaturization in the component level to enhance the computational power is rapidly approaching physical limits, alternative computing methods are vigorously pursued. One of the desired aspects in the future computing approaches is the provision for hardware reconfigurability at run time to allow enhanced functionality. Here we demonstrate a reprogrammable logic device based on the electrothermal frequency modulation scheme of a single microelectromechanical resonator, capable of performing all the fundamental 2-bit logic functions as well as n-bit logic operations. Logic functions are performed by actively tuning the linear resonance frequency of the resonator operated at room temperature and under modest vacuum conditions, reprogrammable by the a.c.-driving frequency. The device is fabricated using complementary metal oxide semiconductor compatible mass fabrication process, suitable for on-chip integration, and promises an alternative electromechanical computing scheme. PMID:27021295

  8. Cold nuclear fusion device

    International Nuclear Information System (INIS)

    Ogino, Shinji.

    1991-01-01

    Selection of cathode material is a key to the attainment of cold nuclear fusion. However, there are only few reports on the cathode material at present and an effective development has been demanded. The device comprises an anode and a cathode and an electrolytic bath having metal salts dissolved therein and containing heavy water in a glass container. The anode is made of gold or platinum and the cathode is made of metals of V, Sr, Y, Nb, Hf or Ta, and a voltage of 3-25V is applied by way of a DC power source between them. The metal comprising V, Sr, Y, Nb, Hf or Ta absorbs deuterium formed by electrolysis of heavy water effectively to cause nuclear fusion reaction at substantially the same frequency and energy efficiency as palladium and titanium. Accordingly, a cold nuclear fusion device having high nuclear fusion generation frequency can be obtained. (N.H.)

  9. Remote controlled transport device

    International Nuclear Information System (INIS)

    Nakahira, Masataka; Oka, Kiyoshi; Ito, Akira; Tada, Eisuke; Sato, Masaki

    1998-01-01

    The present invention provides a device for transporting equipments for maintenance and parts between a maintenance port and a facility for maintenance by remote control in a radioactive material handling facility such as a nuclear power plant. Namely, a power supply bus bar is disposed along a transferring path in order to supply power to a transporting means, and is divided into every region having a predetermined length. Each of the power supply bus bar regions is controlled for the power supply by a control device. Accordingly, the transporting means can be moved and driven successively being independent on every power supply bus bar region. Accordingly, a plurality of transporting means can be operated independently in a transferring path without laying around power cables and control signal cables. (I.S.)

  10. Reactor power control device

    International Nuclear Information System (INIS)

    Ishii, Yoshihiko; Arita, Setsuo; Miyamoto, Yoshiyuki; Fukazawa, Yukihisa; Ishii, Kazuhiko

    1998-01-01

    The present invention provides a reactor power control device capable of enhancing an operation efficiency while keeping high reliability and safety in a BWR type nuclear power plant. Namely, the device of the present invention comprises (1) a means for inputting a set value of a generator power and a set value of a reactor power, (2) a means for controlling the reactor power to either smaller one of the reactor power corresponding to the set value of the generator power and the set value of the reactor power. With such procedures, even if the nuclear power plant is set so as to operate it to make the reactor power 100%, when the generator power reaches the upper limit, the reactor power is controlled with a preference given to the upper limit value of the generator power. Accordingly, safety and reliability are not deteriorated. The operation efficiency of the plant can be improved. (I.S.)

  11. Electromagnetic wave matching device

    International Nuclear Information System (INIS)

    Hirata, Yosuke; Mitsunaka, Yoshika; Hayashi, Ken-ichi; Ito, Yasuyuki.

    1997-01-01

    The present invention provides a matching device capable of increasing an efficiency of combining beams of electromagnetic waves outputted from an output window of a gyrotron which is expected for plasma heating of a thermonuclear reactor and an electromagnetic wave transmission system as high as possible. Namely, an electromagnetic wave matching device reflects beams of electromagnetic waves incident from an inlet by a plurality of phase correction mirrors and combines them to an external transmission system through an exit. In this case, the phase correction mirrors change the phase of the beams of electromagnetic waves incident to the phase correction mirrors by a predetermined amount corresponding to the position of the reflection mirrors. Then, the beams of electromagnetic waves outputted, for example, from a gyrotron can properly be shaped as desired for the intensity and the phase. As a result, combination efficiency with the transmission system can be increased. (I.S.)

  12. Gas processing device

    International Nuclear Information System (INIS)

    Kobayashi, Yoshihiro; Seki, Eiji.

    1991-01-01

    State of electric discharge is detected based on a gas pressure in a sealed container and a discharging current flowing between both of electrodes. When electric arc discharges occur, introduction of gases to be processed is stopped and a voltage applied to both of the electrodes is interrupted. Then, when the gas pressure in the sealed container is lowered to a predetermined value, a power source voltage is applied again to both of the electrodes to recover glow discharges, and the introduction of the gas to be processed is started. With such steps, even if electric arc discharges occur, they are eliminated automatically and, accordingly, normal glow discharges can be recovered, to prevent failures of the device due to electric arc discharges. The glow discharges are recovered automatically without stopping the operation of the gas processing device, and gas injection and solidification processing can be conducted continuously and stably. (T.M.)

  13. Reactor control device

    International Nuclear Information System (INIS)

    Fukami, Haruo; Morimoto, Yoshinori.

    1981-01-01

    Purpose: To operate a reactor always with safety operation while eliminating the danger of tripping. Constitution: In a reactor control device adapted to detect the process variants of a reactor, control a control rod drive controlling system based on the detected signal to thereby control the driving the control rods, control the reactor power and control the electric power generated from an electric generator by the output from the reactor, detection means is provided for the detection of the electric power from said electric generator, and a compensation device is provided for outputting control rod driving compensation signals to the control rod driving controlling system in accordance with the amount of variation in the detected value. (Seki, T.)

  14. Control rod control device

    International Nuclear Information System (INIS)

    Seiji, Takehiko; Obara, Kohei; Yanagihashi, Kazumi

    1998-01-01

    The present invention provides a device suitable for switching of electric motors for driving each of control rods in a nuclear reactor. Namely, in a control rod controlling device, a plurality of previously allotted electric motors connected in parallel as groups, and electric motors of any selected group are driven. In this case, a voltage of not driving predetermined selected electric motors is at first applied. In this state an electric current supplied to the circuit of predetermined electric motors is detected. Whether integration or failure of a power source and the circuit of the predetermined electric motors are normal or not is judged by the detected electric current supplied. After they are judged normal, the electric motors are driven by a regular voltage. With such procedures, whether the selected circuit is normal or not can be accurately confirmed previously. Since the electric motors are not driven just at the selected time, the control rods are not operated erroneously. (I.S.)

  15. TPA device for demonstration

    International Nuclear Information System (INIS)

    1980-02-01

    The TPA (torus plasma for amature) is a small race-trac type device made by the technical service division to demonstrate basic properties of plasma such as electron temperature, conductivity, effect of helical field for toroidal drift, and shape of plasma in mirror and cusp magnetic field in linear section. The plasmas are produced by RF discharge (-500W) and/or DC discharge (-30 mA) within glass discharge tube. Where major radius is 50 cm, length of linear section is 50 cm, toroidal magnetic field is 200 gauss. The device has been designed to be compact with only 100 V power source (-3.2 KW for the case without helical field) and to be full automatic sequence of operation. (author)

  16. Tire deflation device

    Science.gov (United States)

    Barker, Stacey G [Idaho Falls, ID

    2010-01-05

    A tire deflation device includes (1) a component having a plurality of bores, (2) a plurality of spikes removably insertable into the plurality of bores and (3) a keeper within each among the plurality of bores, the keeper being configured to contact a sidewall surface of a spike among the plurality of spikes and to exert force upon the sidewall surface. In an embodiment, the tire deflation device includes (a) a component including a bore in a material, the bore including a receiving region, a sidewall surface and a base surface, (b) a channel extending from the sidewall surface into the material, (c) a keeper having a first section housed within the channel and a second section which extends past the sidewall surface into the receiving region, and (d) a spike removably insertable into the bore.

  17. Microelectromechanical reprogrammable logic device

    KAUST Repository

    Hafiz, Md Abdullah Al

    2016-03-29

    In modern computing, the Boolean logic operations are set by interconnect schemes between the transistors. As the miniaturization in the component level to enhance the computational power is rapidly approaching physical limits, alternative computing methods are vigorously pursued. One of the desired aspects in the future computing approaches is the provision for hardware reconfigurability at run time to allow enhanced functionality. Here we demonstrate a reprogrammable logic device based on the electrothermal frequency modulation scheme of a single microelectromechanical resonator, capable of performing all the fundamental 2-bit logic functions as well as n-bit logic operations. Logic functions are performed by actively tuning the linear resonance frequency of the resonator operated at room temperature and under modest vacuum conditions, reprogrammable by the a.c.-driving frequency. The device is fabricated using complementary metal oxide semiconductor compatible mass fabrication process, suitable for on-chip integration, and promises an alternative electromechanical computing scheme.

  18. Radioactive waste processing device

    International Nuclear Information System (INIS)

    Seki, Shuji.

    1992-01-01

    Liquid wastes are supplied to a ceramic filter to conduct filtration. In this case, a device for adding a powdery inorganic ion exchanger is disposed to the upstream of the ceramic filter. When the powdery inorganic ion exchanger is charged to the addition device, it is precoated to the surface of the ceramic filter, to conduct separation of suspended matters and separation of ionic nuclides simultaneously. Liquid wastes returned to a collecting tank are condensed while being circulated between the ceramic filter and the tank and then contained in a condensation liquid waste tank. With such a constitution, both of radioactive nuclides accompanied by suspended matters in the radioactive liquid wastes and ionic nuclides can be captured efficiently. (T.M.)

  19. Localized environment characterization device

    KAUST Repository

    Alzain, Hashim

    2016-07-21

    Various apparatuses and methods are provided for measuring the likely environmental impact of a particular geographic location on power generation properties of potential solar installations at the particular location. In an example embodiment of one such apparatus, a measurement device is provided. The measurement device includes a base portion comprising a base frame element disposed on a plurality of supporting legs, and a top panel comprising a series of connected members and one or more measurement modules whose planar dimensions are defined by the series of connected members. The top panel is connected to the base portion by a joint such that the top panel can rotate about the joint, and a panel support element is configured to fasten the top panel immovably at a desired degree of rotation in relation to the base portion.

  20. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)