WorldWideScience

Sample records for integrated radiation dosage

  1. Radiation dosage

    Energy Technology Data Exchange (ETDEWEB)

    Finston, Roland [Health Physics, Stanford University, Stanford, CA (United States)

    1986-07-01

    Radiation dosage at Bikini Atoll is the result of current soil contamination, a relic of the nuclear weapons testing program of some 30 years ago. The principal contaminants today and some of their physical properties are listed: cesium-137, strontium-90, plutonium -239, 240 and americium-241. Cobalt-60 contributes less than 1 to the dose and is not considered significant. A resident of the atoll would accumulate radiation dose (rem) in two ways -- by exposure to radiation emanating from the ground and vegetation, and by exposure to radiation released in the spontaneous decay of radionuclides that have entered his body during the ingestion of locally grown foods. The latter process would account for some 90% of the dose; cesium-137 would be responsible for 0 90% of it. Since BARC's method of estimating dosage differs in some respects from that employed by the Lawrence Livermore National Laboratory (LLNL), (Ref.1, LLNL 1982) we are presenting our method in detail. The differences have two sources. First, the numbers used by BARC for the daily ingestion of radionuclides via the diet are higher than LLNL's. Second, BARC's calculation of dose from radionuclide intake utilizes the ICRP system. The net result is that BARC doses are consistently higher than LLNL doses, and in this respect are more conservative.

  2. Radiation dosage

    International Nuclear Information System (INIS)

    Finston, Roland

    1986-01-01

    Radiation dosage at Bikini Atoll is the result of current soil contamination, a relic of the nuclear weapons testing program of some 30 years ago. The principal contaminants today and some of their physical properties are listed: cesium-137, strontium-90, plutonium -239, 240 and americium-241. Cobalt-60 contributes less than 1 to the dose and is not considered significant. A resident of the atoll would accumulate radiation dose (rem) in two ways -- by exposure to radiation emanating from the ground and vegetation, and by exposure to radiation released in the spontaneous decay of radionuclides that have entered his body during the ingestion of locally grown foods. The latter process would account for some 90% of the dose; cesium-137 would be responsible for 0 90% of it. Since BARC's method of estimating dosage differs in some respects from that employed by the Lawrence Livermore National Laboratory (LLNL), (Ref.1, LLNL 1982) we are presenting our method in detail. The differences have two sources. First, the numbers used by BARC for the daily ingestion of radionuclides via the diet are higher than LLNL's. Second, BARC's calculation of dose from radionuclide intake utilizes the ICRP system. The net result is that BARC doses are consistently higher than LLNL doses, and in this respect are more conservative

  3. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  4. Investigation of radiation exposure dosage in dental and panoramic radiography

    International Nuclear Information System (INIS)

    Ishii, Kenichi

    2005-01-01

    Dental radiography and a 10-sheet procedure were conducted at 10 sites in the maxillomandibular anterior teeth and at both sides of the premolar and molar teeth sections with and without a protective apron (total 22 patterns). Experiments, which included a total of five patterns, involving standard ortho-radiography were performed with and without a protective apron, positioning of an apron exclusively on the anterior or the posterior portion of the body and utility of an apron that covered the entire body. Results are as follows: In dental radiography, internal organs included in a bundle demonstrated high radiation exposure, whereas organs excluded from the bundle exhibited low radiation exposure. In organs situated below the thyroid gland, utilization of aprons resulted in lower radiation exposure. In ortho-radiography, radiation exposure was greatest in the parotid gland, followed by the mandibular, sublingual and thyroid glands, respectively. The protective apron resulted in lower radiation exposure at sites situated below the mammary glands; moreover, a protector covering the entire body led to lower radiation exposure in comparison to an apron worn exclusively on the anterior or the posterior aspect of the body. No significant difference was observed in terms of exposure between protective aprons worn on the anterior or the posterior aspect of the body. Furthermore, a protective collar resulted in nearly zero radiation exposure in the thyroid gland. However, a protective collar largely interferes with interpretation of the radiograph; thus, in order to produce interpretable radiographs, protection of the thyroid gland is not possible. In conclusion, radiation exposure dosage can be reduced via utilization of a protective apron positioned below the thyroid gland during dental radiography and below the mammary glands during ortho-radiography. We confirmed evidence indicating that application of a protective apron can reduce patient radiation exposure dosage

  5. When and how should we teach the basic concepts of radiation beam dosage

    Energy Technology Data Exchange (ETDEWEB)

    Brewin, T B [Institute of Radiotherapeutics and Oncology, Glasgow (UK)

    1977-06-01

    The difficulty that many trainees, including those medically qualified, have in achieving a sound working grasp of certain basic principles of radiation beam dosage is often underestimated. Since any failure of understanding may seriously impair the efficiency of the team treating the patient, the discussion of these problems (and especially the monitoring of the results of such discussion by means of oral and written tests) deserves a high priority. Contrary to traditional practice, there would seem to be no good reason why teaching of radiation beam dosage, and the effect on dose-rate of changes in the treatment distance or in the amount of scattered radiation, should not begin in the very first week of training and be immediately integrated with discussion of the dose-rate information available at every radiotherapy unit when the patient is treated. A preliminary course of physics lectures does not usually make the understanding of these principles any easier and can be done either concurrently or later. For many radiotherapy trainees and for many doctors in other fields, comparison with drug dosage and with the brightness and scatter of ordinary light beams, avoiding technical terms so far as possible, may achieve a better initial understanding of basic principles than is achieved by mathematical equations and theoretical physics.

  6. When and how should we teach the basic concepts of radiation beam dosage

    International Nuclear Information System (INIS)

    Brewin, T.B.

    1977-01-01

    The difficulty that many trainees, including those medically qualified, have in achieving a sound working grasp of certain basic principles of radiation beam dosage is often underestimated. Since any failure of understanding may seriously impair the efficiency of the team treating the patient, the discussion of these problems (and especially the monitoring of the results of such discussion by means of oral and written tests) deserves a high priority. Contrary to traditional practice, there would seem to be no good reason why teaching of radiation beam dosage, and the effect on dose-rate of changes in the treatment distance or in the amount of scattered radiation, should not begin in the very first week of training and be immediately integrated with discussion of the dose-rate information available at every radiotherapy unit when the patient is treated. A preliminary course of physics lectures does not usually make the understanding of these principles any easier and can be done either concurrently or later. For many radiotherapy trainees and for many doctors in other fields, comparison with drug dosage and with the brightness and scatter of ordinary light beams, avoiding technical terms so far as possible, may achieve a better initial understanding of basic principles than is achieved by mathematical equations and theoretical physics. (author)

  7. Histomorphological study of submandibulary glands of rats submitted to low dosage of X-radiation

    International Nuclear Information System (INIS)

    Navarro, Claudia Maria; Onofre, Mirian Aparecida; Chan, Carolina; Cordeiro, Rita de Cassis Loiola; Raveli, Dirceu Barnabe

    1996-01-01

    The minimal dosage of X-ray that is likely to induce cellular alterations is unknown and there are just a few reports with low dosage in odontologic literature. The authors developed a histomorphological analysis of the submandibulary glands of rat that received low dosage of X radiation. The body of the animals was covered with a lead lamin leaving the cervical area uncovered. The submandibular glands were exposed to 1,80 Gy of X-radiation in a single dose. After 24, 48, 72 hours, 7, 14 and 21 days the glands were excised, fixed and prepared for analysis in light microscopy. Mild degenerative changes and nuclear pleomorfism, mainly on the first three experimental periods were observed. (author)

  8. Radiation dosages absorbed by the skin during videofluorographic examination of velopharyngeal function

    International Nuclear Information System (INIS)

    Ohara, Hirotoshi; Ogata, Hisao; Nakajima, Tatsuo; Sone, Kiyoaki

    2008-01-01

    Radiographic assessment has become essential in examining the function of the soft palate and pharyngeal walls in patients with velopharyngeal insufficiency. However, in our search of the literature, there was no report on the exposure dose during videofluorographic examination of velopharyngeal function in Japan. Radiation dosages from videofluorography were measured by attaching a glass dosimeter to the submental skin in 17 patients undergoing examination of velopharyngeal function. Sixteen patients underwent a complete videofluorographic examination. For these 16 patients, the mean time of examination was 96.4 sec; the mean radiation dosage absorbed by the skin was 14.4 mGy, equivalent to approximately 7 standard skull x-rays and lower than that during other fluoroscopic procedures. This dose was also lower than the threshold dose at which the skin damage occurs. In light of increasing concern among the general public over radiation exposure, we consider that these data should provide useful information to patients being asked to give informed consent for this examination. (author)

  9. ACE-it: a tool for genome-wide integration of gene dosage and RNA expression data

    NARCIS (Netherlands)

    van Wieringen, W.N.; Belien, J.A.M.; Vosse, S.; Achame, E.M.; Ylstra, B.

    2006-01-01

    Summary: We describe a tool, called ACE-it (Array CGH Expression integration tool). ACE-it links the chromosomal position of the gene dosage measured by array CGH to the genes measured by the expression array. ACE-it uses this link to statistically test whether gene dosage affects RNA expression. ©

  10. Integrative Radiation Biology

    Energy Technology Data Exchange (ETDEWEB)

    Barcellos-Hoff, Mary Helen [New York University School of Medicine, NY (United States)

    2015-02-27

    We plan to study tissue-level mechanisms important to human breast radiation carcinogenesis. We propose that the cell biology of irradiated tissues reveals a coordinated multicellular damage response program in which individual cell contributions are primarily directed towards suppression of carcinogenesis and reestablishment of homeostasis. We identified transforming growth factor β1 (TGFβ) as a pivotal signal. Notably, we have discovered that TGFβ suppresses genomic instability by controlling the intrinsic DNA damage response and centrosome integrity. However, TGFβ also mediates disruption of microenvironment interactions, which drive epithelial to mesenchymal transition in irradiated human mammary epithelial cells. This apparent paradox of positive and negative controls by TGFβ is the topic of the present proposal. First, we postulate that these phenotypes manifest differentially following fractionated or chronic exposures; second, that the interactions of multiple cell types in tissues modify the responses evident in this single cell type culture models. The goals are to: 1) study the effect of low dose rate and fractionated radiation exposure in combination with TGFβ on the irradiated phenotype and genomic instability of non-malignant human epithelial cells; and 2) determine whether stromal-epithelial interactions suppress the irradiated phenotype in cell culture and the humanized mammary mouse model. These data will be used to 3) develop a systems biology model that integrates radiation effects across multiple levels of tissue organization and time. Modeling multicellular radiation responses coordinated via extracellular signaling could have a significant impact on the extrapolation of human health risks from high dose to low dose/rate radiation exposure.

  11. Radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages

    International Nuclear Information System (INIS)

    Chaudakshetrin, P.; Pusuwan, P.; Sritongkul, N.; Tuntawiroon, M.

    2007-01-01

    Full text: Therapeutic doses of I-131 for treatment of thyroid cancer are administered orally in liquid or capsule form. During the last few years, a total number of patients loaded in our isolation ward increased from 4 to 10 patients per week. When considering radiation safety precautions for attending technologists, it is preferable to use the dose in capsules. The purpose of this study is to compare radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages in capsules and in liquid form in a closed system. Materials and Methods: Three year radiation exposure to technologists during I-131 administration was analyzed. From January 2004 to June 2005 dose administration was in liquid form (n=263) and from July 2005 to February 2007 in capsules (n=541). Radiation dose assessment was performed with an electronic personal dosimeter (PDM 112). The dose rate in μSv and time spent per patient were recorded. Results: Dose received per patient when I-131 was given in a liquid was 3.50 ± 1.67 μSv and 1.17 ± 0.66 μSv when given in capsules. Compared with the use of a liquid, capsules significantly reduced radiation dose to technologists by 66% (P < 0.001). These doses received depended not only on the administered activity but also on the time, distance and shielding. Time spent per patient, including a brief visit before the time of dosing to explain the procedure and answer questions was reduced slightly from 4.4 ± 2.2 to 3.7 ± 1.8 minutes (P < 0.01). These correspond to a reduction in a yearly dose to 1 technologist by 40%, from 0.63 mSv to 0.38 mSv from dosing to 175 and 325 patients respectively. Conclusions: The measured doses clearly showed that handling of I-131 therapy dosages either in a liquid form or capsules are not the major contributors to the technologist's radiation exposure in routine clinical practice. However, one has to be cautious and follow good work practice to avoid risk of radiation exposure and radioiodine

  12. Integrative radiation systems biology

    International Nuclear Information System (INIS)

    Unger, Kristian

    2014-01-01

    Maximisation of the ratio of normal tissue preservation and tumour cell reduction is the main concept of radiotherapy alone or combined with chemo-, immuno- or biologically targeted therapy. The foremost parameter influencing this ratio is radiation sensitivity and its modulation towards a more efficient killing of tumour cells and a better preservation of normal tissue at the same time is the overall aim of modern therapy schemas. Nevertheless, this requires a deep understanding of the molecular mechanisms of radiation sensitivity in order to identify its key players as potential therapeutic targets. Moreover, the success of conventional approaches that tried to statistically associate altered radiation sensitivity with any molecular phenotype such as gene expression proofed to be somewhat limited since the number of clinically used targets is rather sparse. However, currently a paradigm shift is taking place from pure frequentistic association analysis to the rather holistic systems biology approach that seeks to mathematically model the system to be investigated and to allow the prediction of an altered phenotype as the function of one single or a signature of biomarkers. Integrative systems biology also considers the data from different molecular levels such as the genome, transcriptome or proteome in order to partially or fully comprehend the causal chain of molecular mechanisms. An example for the application of this concept currently carried out at the Clinical Cooperation Group “Personalized Radiotherapy in Head and Neck Cancer” of the Helmholtz-Zentrum München and the LMU Munich is described. This review article strives for providing a compact overview on the state of the art of systems biology, its actual challenges, potential applications, chances and limitations in radiation oncology research working towards improved personalised therapy concepts using this relatively new methodology

  13. The Integrated Radiation Mapper Assistant

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, R.E.; Tripp, L.R. [Odetics, Inc., Anaheim, CA (United States)

    1995-03-01

    The Integrated Radiation Mapper Assistant (IRMA) system combines state-of-the-art radiation sensors and microprocessor based analysis techniques to perform radiation surveys. Control of the survey function is from a control station located outside the radiation thus reducing time spent in radiation areas performing radiation surveys. The system consists of a directional radiation sensor, a laser range finder, two area radiation sensors, and a video camera mounted on a pan and tilt platform. THis sensor package is deployable on a remotely operated vehicle. The outputs of the system are radiation intensity maps identifying both radiation source intensities and radiation levels throughout the room being surveyed. After completion of the survey, the data can be removed from the control station computer for further analysis or archiving.

  14. Measurement of tissue-radiation dosage using a thermal steady-state elastic shear wave.

    Science.gov (United States)

    Chang, Sheng-Yi; Hsieh, Tung-Sheng; Chen, Wei-Ru; Chen, Jin-Chung; Chou, Chien

    2017-08-01

    A biodosimeter based on thermal-induced elastic shear wave (TIESW) in silicone acellular porcine dermis (SAPD) at thermal steady state has been proposed and demonstrated. A square slab SAPD treated with ionizing radiation was tested. The SAPD becomes a continuous homogeneous and isotropic viscoelastic medium due to the generation of randomly coiled collagen fibers formed from their bundle-like structure in the dermis. A harmonic TIESW then propagates on the surface of the SAPD as measured by a nanometer-scaled strain-stress response under thermal equilibrium conditions at room temperature. TIESW oscillation frequency was noninvasively measured in real time by monitoring the transverse displacement of the TIESW on the SAPD surface. Because the elastic shear modulus is highly sensitive to absorbed doses of ionizing radiation, this proposed biodosimeter can become a highly sensitive and noninvasive method for quantitatively determining tissue-absorbed dosage in terms of TIESW’s oscillation frequency. Detection sensitivity at 1 cGy and dynamic ranges covering 1 to 40 cGy and 80 to 500 cGy were demonstrated.

  15. Radiation oncology systems integration

    International Nuclear Information System (INIS)

    Ragan, D.P.

    1991-01-01

    ROLE7 is intended as a complementary addition to the HL7 Standard and not as an alternative standard. Attempt should be made to mould data elements which are specific to radiation therapy with existing HL7 elements. This can be accomplished by introducing additional values to some element's table-of-options. Those elements which might be specific to radiation therapy could from new segments to be added to the Ancillary Data Reporting set. In order to accomplish ROLE7, consensus groups need be formed to identify the various functions related to radiation oncology that might motivate information exchange. For each of these functions, the specific data elements and their format must be identified. HL7 is organized with a number of applications which communicate asynchronously. Implementation of ROLE7 would allow uniform access to information across vendors and functions. It would provide improved flexibility in system selection. It would allow a more flexible and affordable upgrade path as systems in radiation oncology improve. (author). 5 refs

  16. System integration for radiation records

    International Nuclear Information System (INIS)

    Lawson, B.J.; Farrell, L.; Meacham, C.; Tapio, J.

    1994-01-01

    System integration is the process where through networking and/or software development, necessary business information is available in a common computing environment. System integration is becoming an important objective for many businesses. System integration can improve productivity and efficiency, reduce redundant stored information and errors, and improve availability of information. This paper will discuss the information flow in a radiation health environment, and how system integration can help. Information handled includes external dosimetry and internal dosimetry. The paper will focus on an ORACLE based system integration software product

  17. Transmission microscopy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft X-ray photons

    International Nuclear Information System (INIS)

    Sayre, D.; Feder, R.; Spiller, E.; Kirz, J.; Kim, D.M.

    1977-01-01

    The minimum radiation dosage in a specimen consistent with transmission microscopy at resolution d and specimen thickness t is calculated for model specimens resembling biological materials in their natural state. The calculations cover 10 4 -10 7 eV electrons and 1.3-90 A photons in a number of microscopy modes. The results indicate that over a considerable part of the (t,d)-plane transmission microscopy on such specimens can be carried out at lower dosage with photons than with electrons. Estimates of the maximum resolutions obtainable with electrons and photons, consistent with structural survival of the specimen, are obtained, as are data on optimal operating conditions for microscopy with the two particles

  18. The prospective study of the effect of the low-dosage radiation on the health of the staff members

    International Nuclear Information System (INIS)

    Zhang Shicheng; Jing Luwei; Tian Guang; Liu Linxiu; Wu Wentao

    2008-01-01

    Objective: To study the effect of the long term low-dosage radiation on the health of the staff members in order to provide a scientific basis for the rational protective measures to be taken. Methods: Dynamic observations were made for 15 years of the conditions of the staff members exposed to radiation. The inherent changes and the affecting factors were analyzed. Group of people free from radiation were chosen to the control group. Results: Sighs of nervous breakdown, damages of the eye crystal, hand skin and nails are much more frequently seen among medical radiation workers than these in the control group. There are differences between radiation workers and the control in the positive rates of the objective indices such as leukocytes, erythrocytes, blood platelets, immune functions, the minute nuclei and the chromosome fission. Conclusion: Persistent low-dose radiation can cause damages to the health of radiation workers in many respects, Measures of radiation protection and persistant health monitoring should be taken. Thisis of great importance in implementing the state's relative laws and regulations to protect the health of the radiation workers. (authors)

  19. MicroRNA Expression Profiling Altered by Variant Dosage of Radiation Exposure

    Directory of Open Access Journals (Sweden)

    Kuei-Fang Lee

    2014-01-01

    Full Text Available Various biological effects are associated with radiation exposure. Irradiated cells may elevate the risk for genetic instability, mutation, and cancer under low levels of radiation exposure, in addition to being able to extend the postradiation side effects in normal tissues. Radiation-induced bystander effect (RIBE is the focus of rigorous research as it may promote the development of cancer even at low radiation doses. Alterations in the DNA sequence could not explain these biological effects of radiation and it is thought that epigenetics factors may be involved. Indeed, some microRNAs (or miRNAs have been found to correlate radiation-induced damages and may be potential biomarkers for the various biological effects caused by different levels of radiation exposure. However, the regulatory role that miRNA plays in this aspect remains elusive. In this study, we profiled the expression changes in miRNA under fractionated radiation exposure in human peripheral blood mononuclear cells. By utilizing publicly available microRNA knowledge bases and performing cross validations with our previous gene expression profiling under the same radiation condition, we identified various miRNA-gene interactions specific to different doses of radiation treatment, providing new insights for the molecular underpinnings of radiation injury.

  20. Total radiation dosage from X-ray examinations in rheumatoid arthritis and other chronic skeletal diseases

    International Nuclear Information System (INIS)

    Baldursson, H.; Gustafsson, M.

    1977-01-01

    Young patients with rheumatoid arthritis and other chronic diseases of the skeleton are increasingly being operated on with replacement of major joints. The great number of associated X-ray examinations performed on these patients has caused some anxiety amongst orthopaedic surgeons. Two patients with juvenile rheumatoid arthritis have been studied. An attempt was made to calculate the total radiation dose to bone marrow and gonads. For lack of recommendations for the maximum permissible radiation dose to patients, the dose calculated has been compared with the maximum permissible dose of radiation workers, and with the dose limit for non-occupational irradiation of individuals. The yearly absorbed dose in these two patients is much lower than the maximum permissible dose of radiation workers and only slightly higher than the dose limit for non-occupational exposure of individuals. (author)

  1. The enhancement of natural radiation dosage by coal-fired power generation in the United Kingdom

    International Nuclear Information System (INIS)

    Corbett, J.O.

    1980-02-01

    The total fuel cycle of electricity generation from coal is assessed as a source of enhanced exposure to natural radiation. The various routes by which such exposure can arise are discussed and the consequent individual and collective radiation doses in the United Kingdom are estimated on the basis of a critical review of published data augmented by the results of recent, hitherto unpublished work within the CEGB. Further work is in progress to clarify particular areas of uncertainty that have been identified. (author)

  2. Combined Effects of Egg Age and Gamma Radiation Dosage on egg hatch of Scolytus Amygdali/guer

    International Nuclear Information System (INIS)

    Tadros, A.W.; Abdallah, F.F.; Abdelsalam, K.A.; Hashem, A.G.

    1992-01-01

    Eggs of Scolytus Amygdali were irradiated with 5 to 300 gray of gamma radiation at a dose rate of 7.87 rad/second. One-to five-day-old eggs were used. Results showed that one-and-tow-day-old eggs were the most sensitive as 100% mortality were obtained at 40 and 50 gray, respectively. Three-day-old-eggs required 100 gray to prevent hatch ability; while 300 gray were needed to prevent the 4-and 5-day-old eggs from hatching. There was 7.2-fold increase in resistance as eggs matured from 1 to 5 days measured by dosages required to produce LD 50. 2 fig

  3. Integrated nuclear radiation detector and monitor

    International Nuclear Information System (INIS)

    Biehl, B.L.; Lieberman, S.I.

    1982-01-01

    A battery powered device which can continuously monitor and detect nuclear radiation utilizing fully integrated circuitry and which is provided with an alarm which alerts persons when the radiation level exceeds a predetermined threshold

  4. Radiation dosage to the breast in well-women screening surveys

    Energy Technology Data Exchange (ETDEWEB)

    Asbury, D L; Barker, P G [University Hospital of South Manchester (UK)

    1975-12-01

    The D.H.S.S. is supporting research in several centres to determine the feasibility of establishing a nationwide Breast Cancer Screening Programme. This paper answers the questions 'What is the radiation dose produced by mammography, and is it safe'. In the context of well-women screening surveys a maximum skin dose of 2 R has been recommended. The variation of dose across the breast surface is recorded and the reasons for this enumerated. The lowest mean dose recorded with industrial quality film was 4.9 R, so that such fine-grain film cannot be used for this purpose. Doses within the recommended safety limit are achieved by the use of vacuum-packed film-screen combinations. The new rare-earth phosphor screens produced the lowest dose (0.2 R). There was no significant gonad dose. It is concluded that mammographic examination of well-women can be performed at safe radiation levels.

  5. Integrated NTP Vehicle Radiation Design

    Science.gov (United States)

    Caffrey, Jarvis; Rodriquez, Mitchell

    2018-01-01

    The development of a nuclear thermal propulsion stage requires consideration for radiation emitted from the nuclear reactor core. Applying shielding mass is an effective mitigating solution, but a better alternative is to incorporate some mitigation strategies into the propulsion stage and crew habitat. In this way, the required additional mass is minimized and the mass that must be applied may in some cases be able to serve multiple purposes. Strategies for crew compartment shielding are discussed that reduce dose from both engine and cosmic sources, and in some cases may also serve to reduce life support risks by permitting abundant water reserves. Early consideration for integrated mitigation solutions in a crewed nuclear thermal propulsion (NTP) vehicle will enable reduced radiation burden from both cosmic and nuclear sources, improved thrust-to-weight ratio or payload capacity by reducing 'dead mass' of shielding, and generally support a more robust risk posture for a NTP-powered Mars mission by permitting shorter trip times and increased water reserves

  6. Integrated NTP Vehicle Radiation Design

    Science.gov (United States)

    Caffrey, Jarvis A.; Rodriquez, Mitchell A.

    2018-01-01

    The development of a nuclear thermal propulsion stage requires consideration for radiation emitted from the nuclear reactor core. Applying shielding mass is an effective mitigating solution, but a better alternative is to incorporate some mitigation strategies into the propulsion stage and crew habitat. In this way, the required additional mass is minimized and the mass that must be applied may in some cases be able to serve multiple purposes. Strategies for crew compartment shielding are discussed that reduce dose from both engine and cosmic sources, and in some cases may also serve to reduce life support risks by permitting abundant water reserves. Early consideration for integrated mitigation solutions in a crewed nuclear thermal propulsion (NTP) vehicle will enable reduced radiation burden from both cosmic and nuclear sources, improved thrust-to-weight ratio or payload capacity by reducing 'dead mass' of shielding, and generally support a more robust risk posture for a NTP-powered Mars mission by permitting shorter trip times and increased water reserves.

  7. An Attempt to Measure the Gamma Radiation Dosage at Hiroshima from Photosensitive Material

    Energy Technology Data Exchange (ETDEWEB)

    Brixner, Berlyn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McmIllan, Edwin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-23

    After Japan surrendered in August 1945, a team of Los Alamos scientists entered both Hiroshima and Nagasaki to assess the damage of Little Boy and Fat Man. Two of these scientists, Berlyn Brixner and Edwin McMillan, discovered a stock of photographic film in Hiroshima that had been fogged by the gamma radiation from Little Boy. They devised an experiment that they thought might be used to determine the exposure levels in the city. Below is both their description of the film stock and the attempt to determine the exposure levels at Hiroshima.

  8. Integrated Radiation Analysis and Design Tools

    Data.gov (United States)

    National Aeronautics and Space Administration — The Integrated Radiation Analysis and Design Tools (IRADT) Project develops and maintains an integrated tool set that collects the current best practices, databases,...

  9. Reducing radiation dose in 64-row spiral CT coronary angiography: study based on individualized scan dosage protocol

    International Nuclear Information System (INIS)

    Kang Deqiang; Zhao Jing; Peng Nan; Hua Haiqin; Li Chao; Guo Ying; Shen Yun

    2012-01-01

    Objective: To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol. Methods: Two hundred patients (group A) underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI. The mA was set as 150-300 mA (BMI < 18.5 kg/m2), 300-500 mA (18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 ), and 500-800 mA (BMI ≥ 25.0 kg/m 2 ). When all examinations were finished, a linear regression was employed to analyze the correlation between mA and BMI, body surface (Suf), image noise (SD) respectively. The results of the analysis were used to formulate a regression equation, which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need. Another 200 patients (group B) enrolled for the individualized scan were scanned under new protocol that previous study established. The tube voltage was 100 and 120 kV. The tube current was variable according to the data in the table list. One-way ANOVA and Kruskal-wallis H test were used for statistics. Results: Regression equation between mA and BMI, Suf, SD was: mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039. The SD (group A: 32.08 ± 5.80, group B: 28.60±4.47), dose index volume (CTDI vol ) [group A: (41.97 ± 11.37) mGy, group B: (33.18±10.07) mGy], effective dose(ED) [group A: (10.91 ±3.07) mSy, group B: (8.83 ±2.72)mSv] had significant differences between the two groups (F=43.45, 63.71, 49.07 respectively, P<0.01 for all). The SD and ED results obtained in group B were better than those in group A. Conclusion: Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only, which means good image quality and lower radiation dosage in coronary CTA examination. (authors)

  10. Radiation doses for pediatric nuclear medicine studies: comparing the North American consensus guidelines and the pediatric dosage card of the European Association of Nuclear Medicine.

    Science.gov (United States)

    Grant, Frederick D; Gelfand, Michael J; Drubach, Laura A; Treves, S Ted; Fahey, Frederic H

    2015-04-01

    Estimated radiation dose is important for assessing and communicating the risks and benefits of pediatric nuclear medicine studies. Radiation dose depends on the radiopharmaceutical, the administered activity, and patient factors such as age and size. Most radiation dose estimates for pediatric nuclear medicine have not been based on administered activities of radiopharmaceuticals recommended by established practice guidelines. The dosage card of the European Association of Nuclear Medicine (EANM) and the North American consensus guidelines each provide recommendations of administered activities of radiopharmaceuticals in children, but there are substantial differences between these two guidelines. For 12 commonly performed pediatric nuclear medicine studies, two established pediatric radiopharmaceutical administration guidelines were used to calculate updated radiation dose estimates and to compare the radiation exposure resulting from the recommendations of each of the guidelines. Estimated radiation doses were calculated for 12 common procedures in pediatric nuclear medicine using administered activities recommended by the dosage card of the EANM (version 1.5.2008) and the 2010 North American consensus guidelines for radiopharmaceutical administered activities in pediatrics. Based on standard models and nominal age-based weights, radiation dose was estimated for typical patients at ages 1, 5, 10 and 15 years and adult. The resulting effective doses were compared, with differences greater than 20% considered significant. Following either the EANM dosage card or the 2010 North American guidelines, the highest effective doses occur with radiopharmaceuticals labeled with fluorine-18 and iodine-123. In 24% of cases, following the North American consensus guidelines would result in a substantially higher radiation dose. The guidelines of the EANM dosage card would lead to a substantially higher radiation dose in 39% of all cases, and in 62% of cases in which patients

  11. Radiation doses for pediatric nuclear medicine studies: comparing the North American consensus guidelines and the pediatric dosage card of the European Association of Nuclear Medicine

    International Nuclear Information System (INIS)

    Grant, Frederick D.; Drubach, Laura A.; Treves, S. Ted; Fahey, Frederic H.; Gelfand, Michael J.

    2015-01-01

    Estimated radiation dose is important for assessing and communicating the risks and benefits of pediatric nuclear medicine studies. Radiation dose depends on the radiopharmaceutical, the administered activity, and patient factors such as age and size. Most radiation dose estimates for pediatric nuclear medicine have not been based on administered activities of radiopharmaceuticals recommended by established practice guidelines. The dosage card of the European Association of Nuclear Medicine (EANM) and the North American consensus guidelines each provide recommendations of administered activities of radiopharmaceuticals in children, but there are substantial differences between these two guidelines. For 12 commonly performed pediatric nuclear medicine studies, two established pediatric radiopharmaceutical administration guidelines were used to calculate updated radiation dose estimates and to compare the radiation exposure resulting from the recommendations of each of the guidelines. Estimated radiation doses were calculated for 12 common procedures in pediatric nuclear medicine using administered activities recommended by the dosage card of the EANM (version 1.5.2008) and the 2010 North American consensus guidelines for radiopharmaceutical administered activities in pediatrics. Based on standard models and nominal age-based weights, radiation dose was estimated for typical patients at ages 1, 5, 10 and 15 years and adult. The resulting effective doses were compared, with differences greater than 20% considered significant. Following either the EANM dosage card or the 2010 North American guidelines, the highest effective doses occur with radiopharmaceuticals labeled with fluorine-18 and iodine-123. In 24% of cases, following the North American consensus guidelines would result in a substantially higher radiation dose. The guidelines of the EANM dosage card would lead to a substantially higher radiation dose in 39% of all cases, and in 62% of cases in which patients

  12. Radiation sensitivity of integrated circuits Pt. 1

    International Nuclear Information System (INIS)

    Bereczkine Kerenyi, Ilona

    1986-01-01

    The cosmic ray sensitivity of CMOS integrated circuits are overviewed in three parts. The aim is to analyze the effects of ionizing radiation on the degradation of electronic parameters, the effects of the electric state during irradiation, and the radiation hardening of ICs. In this Part 1 a general introduction of the response of semiconductors to cosmic radiation is given, and the radiation tolerance and hardening of small-scale integrated CMOS ICs is analyzed in detail. The devices include various basic inverters and simple gate ICs. (R.P.)

  13. New exercise-integrated technology can monitor the dosage and quality of exercise performed against an elastic resistance band by adolescents with patellofemoral pain

    DEFF Research Database (Denmark)

    Rathleff, Michael S; Bandholm, Thomas; McGirr, Kate A

    2016-01-01

    QUESTION: Is the exercise-integrated Bandcizer™ system feasible for recording exercise dosage (time under tension (TUT) and repetitions) and pain scores among adolescents with patellofemoral pain? Do adolescents practise the exercises as prescribed (TUT and repetitions)? Do adolescents accurately...... report the exercises they do in an exercise diary? DESIGN: Observational feasibility study. PARTICIPANTS: Twenty adolescents between 15 and 19 years of age with patellofemoral pain. INTERVENTION: Participants were prescribed three exercise sessions per week (one with and two without supervision) for 6......% of the instructed exercise dosage based on TUT. The exercise dosage reported in the exercise diaries was 2.3 times higher than the TUT data from the electronic system. Pain intensity was successfully collected in 100% of the exercise sets. CONCLUSION: The system was feasible for adolescents with patellofemoral pain...

  14. Radiation-hardened CMOS integrated circuits

    International Nuclear Information System (INIS)

    Derbenwick, G.F.; Hughes, R.C.

    1977-01-01

    Electronic circuits that operate properly after exposure to ionizing radiation are necessary for nuclear weapon systems, satellites, and apparatus designed for use in radiation environments. The program to develop and theoretically model radiation-tolerant integrated circuit components has resulted in devices that show an improvement in hardness up to a factor of ten thousand over earlier devices. An inverter circuit produced functions properly after an exposure of 10 6 Gy (Si) which, as far as is known, is the record for an integrated circuit

  15. Integrated occupational radiation exposure information system

    International Nuclear Information System (INIS)

    Hunt, H.W.

    1983-06-01

    The integrated (Occupational Radiation Exposure) data base information system has many advantages. Radiation exposure information is available to operating management in a more timely manner and in a more flexible mode. The ORE system has permitted the integration of scattered files and data to be stored in a more cost-effective method that permits easy and simultaneous access by a variety of users with different data needs. The external storage needs of the radiation exposure source documents are several orders of magnitude less through the use of the computer assisted retrieval techniques employed in the ORE system. Groundwork is being layed to automate the historical files, which are maintained to help describe the radiation protection programs and policies at any one point in time. The file unit will be microfilmed for topical indexing on the ORE data base

  16. Integrated nuclear and radiation protection systems

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, V.; Cerga, V.; Pirvu, V.; Badea, E.

    1993-01-01

    A multifunctional radiation monitoring equipment, flexible and capable to meet virtually environmental radiation monitoring, activity measurement and computational requirements, for nuclear laboratories has been designed. It can be used as a radiation protection system, for radionuclide measurement in isotope laboratories, nuclear technology, health physics and nuclear medicine, nuclear power stations and nuclear industry. The equipment is able to measure, transmit and record gamma dose rate and isotope activities. Other parameters and functions are optionally available, such as: self-contained alarm level, system self-test, dose integrator, syringe volume calculation for a given dose corrected for decay, calibration factor, 99 Mo assays performing and background subtraction

  17. Radiation hardening of integrated circuits technologies

    International Nuclear Information System (INIS)

    Auberton-Herve, A.J.; Leray, J.L.

    1991-01-01

    The radiation hardening studies started in the mid decade -1960-1970. To survive the different military or space radiative environment, a new engineering science borned, to understand the degradation of electronics components. The different solutions to improve the electronic behavior in such environment, have been named radiation hardening of the technologies. Improvement of existing technologies, and qualification method have been widely studied. However, at the other hand, specific technologies was developped : The Silicon On Insulator technologies for CMOS or Bipolar. The HSOI3HD technology (supported by DGA-CEA DAM and LETI with THOMSON TMS) offers today the highest hardening level for the integration density of hundreds of thousand transistors on the same silicon. Full complex systems would be realized on a single die with a technological radiation hardening and no more system hardening

  18. Radiation-hardened CMOS integrated circuits

    International Nuclear Information System (INIS)

    Pikor, A.; Reiss, E.M.

    1980-01-01

    Substantial effort has been directed at radiation-hardening CMOS integrated circuits using various oxide processes. While most of these integrated circuits have been successful in demonstrating megarad hardness, further investigations have shown that the 'wet-oxide process' is most compatible with the RCA CD4000 Series process. This article describes advances in the wet-oxide process that have resulted in multimegarad hardness and yield to MIL-M-38510 screening requirements. The implementation of these advances into volume manufacturing is geared towards supplying devices for aerospace requirements such as the Defense Meterological Satellite program (DMSP) and the Global Positioning Satellite (GPS). (author)

  19. Integration of radiation and physical safety in large radiator facilities

    International Nuclear Information System (INIS)

    Lima, P.P.M.; Benedito, A.M.; Lima, C.M.A.; Silva, F.C.A. da

    2017-01-01

    Growing international concern about radioactive sources after the Sept. 11, 2001 event has led to a strengthening of physical safety. There is evidence that the illicit use of radioactive sources is a real possibility and may result in harmful radiological consequences for the population and the environment. In Brazil there are about 2000 medical, industrial and research facilities with radioactive sources, of which 400 are Category 1 and 2 classified by the - International Atomic Energy Agency - AIEA, where large irradiators occupy a prominent position due to the very high cobalt-60 activities. The radiological safety is well established in these facilities, due to the intense work of the authorities in the Country. In the paper the main aspects on radiological and physical safety applied in the large radiators are presented, in order to integrate both concepts for the benefit of the safety as a whole. The research showed that the items related to radiation safety are well defined, for example, the tests on the access control devices to the irradiation room. On the other hand, items related to physical security, such as effective control of access to the company, use of safety cameras throughout the company, are not yet fully incorporated. Integration of radiation and physical safety is fundamental for total safety. The elaboration of a Brazilian regulation on the subject is of extreme importance

  20. Progress in radiation immune thermionic integrated circuits

    International Nuclear Information System (INIS)

    Lynn, D.K.; McCormick, J.B.

    1985-08-01

    This report describes the results of a program directed at evaluating the thermionic integrated circuit (TIC) technology for applicability to military systems. Previous programs under the sponsorship of the Department of Energy, Office of Basic Energy Sciences, have developed an initial TIC technology base and demonstrated operation in high-temperature and high-radiation environments. The program described in this report has two parts: (1) a technical portion in which experiments and analyses were conducted to refine perceptions of near-term as well as ultimate performance levels of the TIC technology and (2) an applications portion in which the technical conclusions were to be evaluated against potential military applications. This report draws several conclusions that strongly suggest that (1) useful radiation-hard/high-temperature operable integrated circuits can be developed using the TIC technology; (2) because of their ability to survive and operate in hostile environments, a variety of potential military applications have been projected for this technology; and (3) based on the above two conclusions, an aggressive TIC development program should be initiated to provide the designers of future systems with integrated circuits and devices with the unique features of the TICs

  1. Integration of video and radiation analysis data

    International Nuclear Information System (INIS)

    Menlove, H.O.; Howell, J.A.; Rodriguez, C.A.; Eccleston, G.W.; Beddingfield, D.; Smith, J.E.; Baumgart, C.W.

    1995-01-01

    For the past several years, the integration of containment and surveillance (C/S) with nondestructive assay (NDA) sensors for monitoring the movement of nuclear material has focused on the hardware and communications protocols in the transmission network. Little progress has been made in methods to utilize the combined C/S and NDA data for safeguards and to reduce the inspector time spent in nuclear facilities. One of the fundamental problems in the integration of the combined data is that the two methods operate in different dimensions. The C/S video data is spatial in nature; whereas, the NDA sensors provide radiation levels versus time data. The authors have introduced a new method to integrate spatial (digital video) with time (radiation monitoring) information. This technology is based on pattern recognition by neural networks, provides significant capability to analyze complex data, and has the ability to learn and adapt to changing situations. This technique has the potential of significantly reducing the frequency of inspection visits to key facilities without a loss of safeguards effectiveness

  2. Progress in radiation immune thermionic integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Lynn, D.K.; McCormick, J.B. (comps.)

    1985-08-01

    This report describes the results of a program directed at evaluating the thermionic integrated circuit (TIC) technology for applicability to military systems. Previous programs under the sponsorship of the Department of Energy, Office of Basic Energy Sciences, have developed an initial TIC technology base and demonstrated operation in high-temperature and high-radiation environments. The program described in this report has two parts: (1) a technical portion in which experiments and analyses were conducted to refine perceptions of near-term as well as ultimate performance levels of the TIC technology and (2) an applications portion in which the technical conclusions were to be evaluated against potential military applications. This report draws several conclusions that strongly suggest that (1) useful radiation-hard/high-temperature operable integrated circuits can be developed using the TIC technology; (2) because of their ability to survive and operate in hostile environments, a variety of potential military applications have been projected for this technology; and (3) based on the above two conclusions, an aggressive TIC development program should be initiated to provide the designers of future systems with integrated circuits and devices with the unique features of the TICs.

  3. Radiation damage to integrated injection logic cells

    International Nuclear Information System (INIS)

    Pease, R.L.; Galloway, K.F.; Stehlin, R.A.

    1975-01-01

    The effects of neutron and total dose gamma irradiations on the electrical characteristics of an integrated injection logic (l 2 L) cell and an l 2 L multiple inverter circuit were investigated. These units were designed and fabricated to obtain circuit development information and did not have radiation hardness as a goal. The following parameters of the test structures were measured as a function of total dose and neutron fluence: the dc common-base current gain of the lateral pnp transistor; the dc common-emitter current gain of the vertical npn transistor; the forward current-voltage characteristics of the injector-substrate junction, and the propagation delay versus power dissipation per gate for the multiple inverter circuit. The limitations of the present test structures in a radiation environment and possible hardening techniques are discussed

  4. Integrative Metabolic Signatures for Hepatic Radiation Injury.

    Directory of Open Access Journals (Sweden)

    Irwin Jack Kurland

    Full Text Available Radiation-induced liver disease (RILD is a dose-limiting factor in curative radiation therapy (RT for liver cancers, making early detection of radiation-associated liver injury absolutely essential for medical intervention. A metabolomic approach was used to determine metabolic signatures that could serve as biomarkers for early detection of RILD in mice.Anesthetized C57BL/6 mice received 0, 10 or 50 Gy Whole Liver Irradiation (WLI and were contrasted to mice, which received 10 Gy whole body irradiation (WBI. Liver and plasma samples were collected at 24 hours after irradiation. The samples were processed using Gas Chromatography/Mass Spectrometry and Liquid Chromatography/Mass Spectrometry.Twenty four hours after WLI, 407 metabolites were detected in liver samples while 347 metabolites were detected in plasma. Plasma metabolites associated with 50 Gy WLI included several amino acids, purine and pyrimidine metabolites, microbial metabolites, and most prominently bradykinin and 3-indoxyl-sulfate. Liver metabolites associated with 50 Gy WLI included pentose phosphate, purine, and pyrimidine metabolites in liver. Plasma biomarkers in common between WLI and WBI were enriched in microbial metabolites such as 3 indoxyl sulfate, indole-3-lactic acid, phenyllactic acid, pipecolic acid, hippuric acid, and markers of DNA damage such as 2-deoxyuridine. Metabolites associated with tryptophan and indoles may reflect radiation-induced gut microbiome effects. Predominant liver biomarkers in common between WBI and WLI were amino acids, sugars, TCA metabolites (fumarate, fatty acids (lineolate, n-hexadecanoic acid and DNA damage markers (uridine.We identified a set of metabolomic markers that may prove useful as plasma biomarkers of RILD and WBI. Pathway analysis also suggested that the unique metabolic changes observed after liver irradiation was an integrative response of the intestine, liver and kidney.

  5. Estimation of radiation dosage and transmutation effect of 14C involved in measuring rate of albumin synthesis with 14C-carbonate

    International Nuclear Information System (INIS)

    Yap, A.H.; Hafkenscheid, J.C.M.; Goossens, C.M.I.C.; Buys, W.C.A.M.; Binkhorst, R.A.; Van Tongeren, J.H.M.

    1975-01-01

    For direct measurement of the rate of albumin synthesis, Na 2 14 CO 3 was used intravenously. The assessment of the radiation hazard involved in the study was based on the knowledge of the minimum dose of Na 2 14 CO 3 necessary for a sufficient incorporation of 14 C in the guanidine-C of arginine in albumin to obtain measurable radioactivity. By measurement of expired 14 CO 2 and excreted 14 C-urea in the urine during a 5-hr period following intravenous administration of Na 2 14 CO 3 in five subjects, some quantitative data on 14 C retention and radiation dosage were obtained. In comparison with animal studies, the rate of expiration of 14 CO 2 in man is slower. About 50 percent of the total radioactivity injected was lost through the respiratory route in the first hour. The total amount of expired 14 C during the 5 hr of investigation was about 75 percent of the injected dose for the five subjects. The amount of 14 C excreted as urinary 14 C-urea during the 5 hr of investigation is very small in comparison with the expired 14 C; it was only about 0.5 percent of the dose injected. The total absorbed radiation dose after complete elimination of 14 C from the body was calculated with various assumptions. The extra risk of genetic damage due to disintegration of retained 14 C in comparison with that of natural 14 C in the body during 30 living years is about 50 percent. (U.S.)

  6. Integral -tracking extreme radiation across the Universe

    Science.gov (United States)

    2002-10-01

    . Galactic black holes also give off gamma rays, and with such awesome power that you can detect them almost halfway across the known Universe. As well as making the most accurate studies of these objects to date, Integral will also investigate the mysterious blasts of gamma rays that explode across the Universe about once a day, the gamma-ray bursts. They can last just a few seconds and can come from any direction in space. The origin of gamma-ray bursts has remained unexplained for years, from their first observation in the late 1960s. Today, many scientists think that gamma ray bursts could be linked to the death throes of the very first stars. Alternatively, they could be generated by colliding neutron stars, or could be caused by the explosion of supermassive stars at the end of their lives, the hypernovae. Integral's instruments will study gamma-ray bursts with the highest accuracy ever and may discover something about their origins. Integral’s instruments Integral has four instruments to give the spacecraft maximum versatility in its task of studying the gamma-ray Universe. Designed to complement each other, their combined observations will allow scientists to get a very complete and accurate picture of each celestial target at different wavelengths. The first two are dedicated gamma-ray instruments. Imager on Board the Integral Satellite (IBIS) is the sharpest-resolution gamma-ray camera ever built. Spectrometer on Integral (SPI) will measure the energy of gamma rays with exceptional accuracy. In particular, it will be more sensitive to fainter radiation than any previous gamma-ray spectrometer. The other two instruments are designed to provide complementary scientific data about Integral’s targets. The Joint European X-Ray Monitor (JEM-X) will make observations simultaneously with the main gamma-ray instruments and will provide images at X-ray wavelengths. The Optical Monitoring Camera (OMC) will do the same but at visible-light wavelengths. The total weight of

  7. Further results on a family of generalized radiation integrals

    International Nuclear Information System (INIS)

    Galue, Leda; Kiryakova, Virginia

    1994-01-01

    In this paper we continue an investigation of a family of generalized radiation integrals. Several recurrence relations are presented. By differentiation of these integrals with respect to the parameters λ and μ we obtain also various integrals that include the logarithmic function in the integrand. Finally, we propose an algorithm for numerical evaluation of the generalized radiation integrals and illustrate it by tables of their values computed for selected values of the parameters. (author)

  8. An integrated model for radiation induced cancer

    International Nuclear Information System (INIS)

    Hall, E.J.; Varma, M.

    1994-01-01

    Risk estimates for radiation induced cancer are based on epidemiological data, principally the Japanese A bomb survivors. These estimates for radiation are better known than for any other environmental pollutant, but they do not relate directly to exposure to low doses and low dose rate. Recent rapid advances in molecular genetics, coupled with steady gains in cellular biology, radiation physics and chemistry led to the notion that the time may not be far off when it may be possible to arrive at human cancer risk estimates entirely from laboratory data. Whether risk estimates based on laboratory data will ever replace estimates based on epidemiological studies is an open question. What is clear is that laboratory data can supplement the present risk estimates by providing information on the relative effectiveness of high LET radiations, the importance of dose rate and dose protraction, and by identifying subpopulations which are unusually sensitive or resistant to radiation carcinogenesis. (author)

  9. Impaired skin integrity related to radiation therapy

    International Nuclear Information System (INIS)

    Ratliff, C.

    1990-01-01

    Skin reactions associated with radiation therapy require frequent nursing assessment and intervention. Preventive interventions and early management can minimize the severity of the skin reaction. With the understanding of the pathogenesis of radiation skin reactions, the ET nurse can determine who is at risk and then implement preventive measures. Because radiation treatment is fractionated, skin reactions do not usually occur until midway through the course of therapy and will subside within a few weeks after completion of radiation. Many patients and their families still fear that radiation causes severe burns. Teaching and anticipatory guidance by the ET nurse is needed to assist patients and their families to overcome this fear, and to educate them on preventive skin care regimens

  10. Equivalence of some integrals of the radiation theory

    International Nuclear Information System (INIS)

    Chia, T.T.

    1977-01-01

    A definite integral which occurs in radiation theory is shown to be equal in value to another definite integral by evaluating the flux from a spherically symmetrical radiating sphere in two ways. As a corollary, an alternate proof of the invariance of the specific intensity of a ray in empty space along its path is presented. Furthermore, the equality of these two indefinite integrals leads to the conversion of members of a class of indefinite and definite integrals involving arbitrary functions of angle into other integrals. These transformations facilitate the calculation of some of these integrals which arise not only in the theory of radiation, but in other physical situations with spherical or axial symmetry - especially those in which inverse-square laws are involved. (Auth.)

  11. Radiation effects on the integrity of paper

    International Nuclear Information System (INIS)

    Otero D'Almeida, Maria Luiza; Medeiros Barbosa, Patricia de Souza; Boaratti, Marcelo Fernando Guerra; Borrely, Sueli Ivone

    2009-01-01

    Books and documents attacked by fungi and insects have already been treated by radiation for disinfestations purposes. However, there is still need to investigate the influence of radiation on the cellulose paper structure. The aim of this research was to study the effects of radiation on paper properties, especially those related to strength and appearance. Paper sheets for this study were prepared in the laboratory, using bleached eucalyptus pulp as raw material. No additives were used to concentrate the attention only on the effects of irradiation on the pure cellulose matrix. The samples were irradiated at IPEN's 60 Co Gammacell irradiator with six radiation doses, from 3 to 15 kGy at the dose rate 0.817 Gy/s. The properties of paper sheets were tested after irradiation and compared with unirradiated samples according to ISO methods. No significant changes were detected in paper samples irradiated up to 15 kGy.

  12. An integrated system for dissolution studies and magnetic resonance imaging of controlled release, polymer-based dosage forms-a tool for quantitative assessment of hydrogel formation processes.

    Science.gov (United States)

    Kulinowski, Piotr; Dorozyński, Przemysław; Jachowicz, Renata; Weglarz, Władysław P

    2008-11-04

    Controlled release (CR) dosage forms are often based on polymeric matrices, e.g., sustained-release tablets and capsules. It is crucial to visualise and quantify processes of the hydrogel formation during the standard dissolution study. A method for imaging of CR, polymer-based dosage forms during dissolution study in vitro is presented. Imaging was performed in a non-invasive way by means of the magnetic resonance imaging (MRI). This study was designed to simulate in vivo conditions regarding temperature, volume, state and composition of dissolution media. Two formulations of hydrodynamically balanced systems (HBS) were chosen as model CR dosage forms. HBS release active substance in stomach while floating on the surface of the gastric content. Time evolutions of the diffusion region, hydrogel formation region and "dry core" region were obtained during a dissolution study of L-dopa as a model drug in two simulated gastric fluids (i.e. in fed and fasted state). This method seems to be a very promising tool for examining properties of new formulations of CR, polymer-based dosage forms or for comparison of generic and originator dosage forms before carrying out bioequivalence studies.

  13. Double gated-integrator for shaping nuclear radiation detector signals

    International Nuclear Information System (INIS)

    Gal, J.

    2001-01-01

    A new shaper, the double gated-integrator, for shaping nuclear radiation detector signals is investigated both theoretically and experimentally. The double gated-integrator consists of a pre-filter and two cascaded gated integrators. Two kinds of pre-filters were considered: a rectangular one and an exponential one. The results of the theoretical calculation show that the best figure of demerit for the double gated-integrator with exponential pre-filter is 1.016. This means that its noise to signal ratio is only 1.6% worse than that it is for infinite cusp shaping. The practical realization of the exponential pre-filter and that of the double gated integrator, both in analogue and in digital way, is very simple. Therefore, the double gated-integrator with exponential pre-filter could be a promising solution for shaping nuclear radiation detector signals

  14. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  15. An integrated artificial neural networks approach for predicting global radiation

    International Nuclear Information System (INIS)

    Azadeh, A.; Maghsoudi, A.; Sohrabkhani, S.

    2009-01-01

    This article presents an integrated artificial neural network (ANN) approach for predicting solar global radiation by climatological variables. The integrated ANN trains and tests data with multi layer perceptron (MLP) approach which has the lowest mean absolute percentage error (MAPE). The proposed approach is particularly useful for locations where no available measurement equipment. Also, it considers all related climatological and meteorological parameters as input variables. To show the applicability and superiority of the integrated ANN approach, monthly data were collected for 6 years (1995-2000) in six nominal cities in Iran. Separate model for each city is considered and the quantity of solar global radiation in each city is calculated. Furthermore an integrated ANN model has been introduced for prediction of solar global radiation. The acquired results of the integrated model have shown high accuracy of about 94%. The results of the integrated model have been compared with traditional angstrom's model to show its considerable accuracy. Therefore, the proposed approach can be used as an efficient tool for prediction of solar radiation in the remote and rural locations with no direct measurement equipment.

  16. NASA Space Radiation Program Integrative Risk Model Toolkit

    Science.gov (United States)

    Kim, Myung-Hee Y.; Hu, Shaowen; Plante, Ianik; Ponomarev, Artem L.; Sandridge, Chris

    2015-01-01

    NASA Space Radiation Program Element scientists have been actively involved in development of an integrative risk models toolkit that includes models for acute radiation risk and organ dose projection (ARRBOD), NASA space radiation cancer risk projection (NSCR), hemocyte dose estimation (HemoDose), GCR event-based risk model code (GERMcode), and relativistic ion tracks (RITRACKS), NASA radiation track image (NASARTI), and the On-Line Tool for the Assessment of Radiation in Space (OLTARIS). This session will introduce the components of the risk toolkit with opportunity for hands on demonstrations. The brief descriptions of each tools are: ARRBOD for Organ dose projection and acute radiation risk calculation from exposure to solar particle event; NSCR for Projection of cancer risk from exposure to space radiation; HemoDose for retrospective dose estimation by using multi-type blood cell counts; GERMcode for basic physical and biophysical properties for an ion beam, and biophysical and radiobiological properties for a beam transport to the target in the NASA Space Radiation Laboratory beam line; RITRACKS for simulation of heavy ion and delta-ray track structure, radiation chemistry, DNA structure and DNA damage at the molecular scale; NASARTI for modeling of the effects of space radiation on human cells and tissue by incorporating a physical model of tracks, cell nucleus, and DNA damage foci with image segmentation for the automated count; and OLTARIS, an integrated tool set utilizing HZETRN (High Charge and Energy Transport) intended to help scientists and engineers study the effects of space radiation on shielding materials, electronics, and biological systems.

  17. Integrating the Healthcare Enterprise in Radiation Oncology Plug and Play-The Future of Radiation Oncology?

    International Nuclear Information System (INIS)

    Abdel-Wahab, May; Rengan, Ramesh; Curran, Bruce; Swerdloff, Stuart; Miettinen, Mika; Field, Colin; Ranjitkar, Sunita; Palta, Jatinder; Tripuraneni, Prabhakar

    2010-01-01

    Purpose: To describe the processes and benefits of the integrating healthcare enterprises in radiation oncology (IHE-RO). Methods: The IHE-RO process includes five basic steps. The first step is to identify common interoperability issues encountered in radiation treatment planning and the delivery process. IHE-RO committees partner with vendors to develop solutions (integration profiles) to interoperability problems. The broad application of these integration profiles across a variety of vender platforms is tested annually at the Connectathon event. Demonstration of the seamless integration and transfer of patient data to the potential users are then presented by vendors at the public demonstration event. Users can then integrate these profiles into requests for proposals and vendor contracts by institutions. Results: Incorporation of completed integration profiles into requests for proposals can be done when purchasing new equipment. Vendors can publish IHE integration statements to document the integration profiles supported by their products. As a result, users can reference integration profiles in requests for proposals, simplifying the systems acquisition process. These IHE-RO solutions are now available in many of the commercial radiation oncology-related treatment planning, delivery, and information systems. They are also implemented at cancer care sites around the world. Conclusions: IHE-RO serves an important purpose for the radiation oncology community at large.

  18. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  19. Analysis of integrated video and radiation data

    International Nuclear Information System (INIS)

    Howell, J.A.; Menlove, H.O.; Rodriguez, C.A.; Beddingfield, D.; Vasil, A.

    1995-01-01

    We have developed prototype software for a facility-monitoring application that will detect anomalous activity in a nuclear facility. The software, which forms the basis of a simple model, automatically reviews and analyzes integrated safeguards data from continuous unattended monitoring systems. This technology, based on pattern recognition by neural networks, provides significant capability to analyze complex data and has the ability to learn and adapt to changing situations. It is well suited for large automated facilities, reactors, spent-fuel storage facilities, reprocessing plants, and nuclear material storage vaults

  20. Radiation response of high speed CMOS integrated circuits

    International Nuclear Information System (INIS)

    Yue, H.; Davison, D.; Jennings, R.F.; Lothongkam, P.; Rinerson, D.; Wyland, D.

    1987-01-01

    This paper studies the total dose and dose rate radiation response of the FCT family of high speed CMOS integrated circuits. Data taken on the devices is used to establish the dominant failure modes, and this data is further analyzed using one-sided tolerance factors for normal distribution statistical analysis

  1. Integration of optical fibers in radiative environments: Advantages and limitations

    International Nuclear Information System (INIS)

    Girard, S.; Ouerdane, Y.; Boukenter, A.; Marcandella, C.; Bisutti, J.; Baggio, J.; Meunier, J. P.

    2011-01-01

    We review the advantages and limitations for the integration of optical fibers in radiative environments. Optical fibers present numerous advantages for applications in harsh environments such as their electromagnetic immunity. This explains the increasing interest of the radiation effects community to evaluate their vulnerability for future facilities. However, it is also well-known that optical fibers suffer from a degradation of their macroscopic properties under irradiation. We illustrate the major mechanisms and parameters that govern the degradation mechanism, mainly the radiation-induced attenuation phenomena. We focus on the fiber transient radiation responses when exposed to the pulsed and mixed environment associated with the Megajoule class lasers devoted to the fusion by inertial confinement study. (authors)

  2. Radiation effects in semiconductors: technologies for hardened integrated circuits

    International Nuclear Information System (INIS)

    Charlot, J.M.

    1983-09-01

    Various technologies are used to manufacture integrated circuits for electronic systems. But for specific applications, including those with radiation environment, it is necessary to choose an appropriate technologie or to improve a specific one in order to reach a definite hardening level. The aim of this paper is to present the main effects induced by radiation (neutrons and gamma rays) into the basic semiconductor devices, to explain some physical degradation mechanisms and to propose solutions for hardened integrated circuit fabrication. The analysis involves essentially the monolithic structure of the integrated circuits and the isolation technology of active elements. In conclusion, the advantages of EPIC and SOS technologies are described and the potentialities of new technologies (GaAs and SOI) are presented

  3. Radiation effects in semiconductors: technologies for hardened integrated circuits

    International Nuclear Information System (INIS)

    Charlot, J.M.

    1984-01-01

    Various technologies are used to manufacture integrated circuits for electronic systems. But for specific applications, including those with radiation environment, it is necessary to choose an appropriate technology or to improve a specific one in order to reach a definite hardening level. The aim of this paper is to present the main effects induced by radiation (neutrons and gamma rays) into the basic semiconductor devices, to explain some physical degradation mechanisms and to propose solutions for hardened integrated circuit fabrication. The analysis involves essentially the monolithic structure of the integrated circuits and the isolation technology of active elements. In conclusion, the advantages of EPIC and SOS technologies are described and the potentialities of new technologies (GaAs and SOI) are presented. (author)

  4. Integration of radiation monitoring for nuclear emergency response teams

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, J T; Thompson, N Y [Royal Military Coll. of Canada, Kingston, ON (Canada)

    1994-12-31

    The Canadian Forces have established Nuclear Emergency Response Teams to cope with potential radiation accidents. Previously, only gamma and high-energy beta radiation could be detected. Recently, new radiation sampling, detecting, and analytical equipment has been bought, including air samplers, beta counters, high-purity germanium gamma detectors, and multi-channel analyzers together with Gamma Vision Software to analyze gamma spectra. The purpose of the present study is to propose a way to use the new equipment, to analyze the results from the gamma and beta detectors, and to integrate the results into a format for decision making. Integration is achieved through the creation of a computer program, Radiation Integration Program (RIP). This program analyzes gross beta counts, and uses them to estimate danger to the thyroid. As well the results from Gamma Vision are converted from Bq to dose rate for several parts of the body. Overall gamma results affecting the thyroid are compared to the beta results to verify the initial estimations.

  5. Design optimization of radiation-hardened CMOS integrated circuits

    International Nuclear Information System (INIS)

    1975-01-01

    Ionizing-radiation-induced threshold voltage shifts in CMOS integrated circuits will drastically degrade circuit performance unless the design parameters related to the fabrication process are properly chosen. To formulate an approach to CMOS design optimization, experimentally observed analytical relationships showing strong dependences between threshold voltage shifts and silicon dioxide thickness are utilized. These measurements were made using radiation-hardened aluminum-gate CMOS inverter circuits and have been corroborated by independent data taken from MOS capacitor structures. Knowledge of these relationships allows one to define ranges of acceptable CMOS design parameters based upon radiation-hardening capabilities and post-irradiation performance specifications. Furthermore, they permit actual design optimization of CMOS integrated circuits which results in optimum pre- and post-irradiation performance with respect to speed, noise margins, and quiescent power consumption. Theoretical and experimental results of these procedures, the applications of which can mean the difference between failure and success of a CMOS integrated circuit in a radiation environment, are presented

  6. Integrated radiation information system in the Czech Republic

    International Nuclear Information System (INIS)

    Drabova, D.; Prouza, Z.; Malatova, I.; Kuca, P.; Bucina, I.

    1998-01-01

    Outline and organizational structure of radiation monitoring network (RMN) in the Czech Republic is conformable with similar networks abroad integrated system of a number of components serve for continuous monitoring of radiation situation on the territory of the Czech Republic, detecting an abnormal radiological situation due to domestic source, detecting a non notified accident abroad with consequences on the territory of the Czech Republic, monitoring the evolution, determining the components of any radioactivity discharge, first estimation of accident extent, forecasting of accident development and of dispersion of radionuclides in the vicinity of source, acquisition of base for decision upon evaluation and other countermeasures and remedial actions, assessment and forecast of contamination for regulation of food and water consumption, review of enforced countermeasures based on actual monitoring data and refined forecast. For model calculations and decision making in case of a nuclear accident an integrated comprehensive computer based information system is now being set up in Czech Republic. (R.P.)

  7. Study concerning an integrated radiation monitoring systems for nuclear facilities

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, M.; Cerga, V.; Pirvu, V; Badea, E.

    1996-01-01

    This paper presents an integrated radiation monitoring system designed to assess the effects of nuclear accidents and to provide a basis for making right decisions and countermeasures in order to reduce health damages. The system implies a number of stationary monitoring equipment, data processing unit and a communication network. The system meets the demands of efficiency and reliability, providing the needed tools to easily create programs able to process simple input data filling the information management system. (author). 10 refs

  8. Evaluation of integrity of radiation sources of nuclear gauges

    International Nuclear Information System (INIS)

    Torohate, Wiclif Francisco

    2016-01-01

    Nuclear equipment meters are mainly used in the industry in quality control and process control. The principle of operation consists in a shielded radioactive source together with a radiation detector such that the radiation interacts with the material to be analyzed before reaching the detector, providing real time data. Can be as their fixed and mobile mobility, the unique properties of ionizing radiation are used in three basic modes, transmission, backscatter or dispersion or induced (reactive). With the advancement and technological modernization in the world, the demand for nuclear gauges becomes increasingly larger. Currently in Brazil there are about 465 process control plants and 21 portable systems and Mozambique about 45 facilities using nuclear gauges. This font registration is done through a process called source inventory that allows also to know the category of the source, the danger or risk to human health that the source offers. The handling of this equipment requires personnel, certified, skilled and well trained in radiation protection area in accordance with the requirements of the various CNEN Rules. Due to the presence of radioactive source and because these devices are used by workers risk because there external radiation. In this context, we made the smear test in two fixed meters from the IRD industry laboratory, which determines the integrity of the source package, mandatory item in periodic integrity testing of the radiation source of this type of device. A set of procedures is made for its implementation as an evaluation of the radiological risk by radiological survey. It was intended to contribute to the learning handling and safe use of these meters. (author)

  9. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  10. Clinical criteria for medical staff exposure and reference dosage within the Galician health Service

    International Nuclear Information System (INIS)

    Garcia Comesana, J.

    2003-01-01

    The generalised use of ionising radiation tests is making these tests become the prime cause of exposure to artificial radiation, receiving one sixth of the dosage through background radiation. (Author)

  11. Assessment of integrated solar ultraviolet radiation by PM-355 detectors

    International Nuclear Information System (INIS)

    Abu-Jarad, F.; Al-Jarallah, M.I.; Elhadidy, M.A.; Shaahid, S.M.; Fazal-ur-Rehman

    2000-01-01

    The increase in environmental solar UV radiation due to depletion of ozone layer is a recent challenge to human health (skin cancer and eye effects) in countries having clear skies. Therefore, applying integrated, passive and inexpensive techniques to assess solar UV radiation is very much essential. Measurements of environmental solar UV radiation in Dhahran, Saudi Arabia area were carried out for a period of two months in the summer period in 1996 using two techniques in parallel namely: passive nuclear track detectors and active solar UV radiometers. Some of the nuclear track detectors were mounted in different conditions such as: under shadow band, on solar tracking mechanism following the solar rays. Others were mounted on perpendicular, tilted and horizontal surfaces in sunlight. All detectors were attached to a wooden background of the same thickness (0.5 cm) to eliminate interference of the heat effect of various support materials and have uniformity of the support materials. The assessment was carried out for different periods extending from two to nine weeks continuously. The investigated period covered the hottest months in Saudi Arabia (July and August) when the sky was clear of clouds. The results indicate linear correlation between alpha track diameters and the integrated exposure to solar UV as measured by the solar UV radiometer for all nuclear track detector positions and orientations. The highest slope has been observed for the detectors placed on solar tracking mechanism following the solar rays and the lowest from detectors oriented under the shadow band on horizontal position (measuring the diffused UV radiation only). The results show that most of the measured UV radiation (60%) were from the diffused UV radiation. The characteristics of the upper layer of the detectors are changed after chemical etching very quickly, with increase in the exposure time to UV solar radiation at certain orientation. The results encourage the use of nuclear track

  12. Assessment of integrated solar ultraviolet radiation by PM-355 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Al-Jarallah, M.I.; Elhadidy, M.A.; Shaahid, S.M.; Fazal-ur-Rehman

    2000-06-01

    The increase in environmental solar UV radiation due to depletion of ozone layer is a recent challenge to human health (skin cancer and eye effects) in countries having clear skies. Therefore, applying integrated, passive and inexpensive techniques to assess solar UV radiation is very much essential. Measurements of environmental solar UV radiation in Dhahran, Saudi Arabia area were carried out for a period of two months in the summer period in 1996 using two techniques in parallel namely: passive nuclear track detectors and active solar UV radiometers. Some of the nuclear track detectors were mounted in different conditions such as: under shadow band, on solar tracking mechanism following the solar rays. Others were mounted on perpendicular, tilted and horizontal surfaces in sunlight. All detectors were attached to a wooden background of the same thickness (0.5 cm) to eliminate interference of the heat effect of various support materials and have uniformity of the support materials. The assessment was carried out for different periods extending from two to nine weeks continuously. The investigated period covered the hottest months in Saudi Arabia (July and August) when the sky was clear of clouds. The results indicate linear correlation between alpha track diameters and the integrated exposure to solar UV as measured by the solar UV radiometer for all nuclear track detector positions and orientations. The highest slope has been observed for the detectors placed on solar tracking mechanism following the solar rays and the lowest from detectors oriented under the shadow band on horizontal position (measuring the diffused UV radiation only). The results show that most of the measured UV radiation (60%) were from the diffused UV radiation. The characteristics of the upper layer of the detectors are changed after chemical etching very quickly, with increase in the exposure time to UV solar radiation at certain orientation. The results encourage the use of nuclear track

  13. Radiation-induced attenuation in integrated optical materials

    International Nuclear Information System (INIS)

    Evans, B.D.

    1989-01-01

    This paper reports that three materials commonly employed in opto-electronic integrated circuits evaluated for radiation-induced optical attenuation in the range 300 nm to 3000 nm. These include optically clear epoxy and crystalline lithium niobate after Co-60 exposure and crystalline tellurium dioxide after mixed gamma/fast-neutron exposure. In all these materials, however, induced loss was restricted to shorter wavelengths; attenuation induced at the telecommunications windows near 850, 1300 and 1550 nm was <0.1 dB/cm

  14. Endotoxin dosage in sepsis

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2012-03-01

    Full Text Available Introduction. Endotoxin, a component of the cell wall of Gram-negative bacteria is a major contributor to the pathogenesis of septic shock and multiple organ failure (MOF. Its entry into the bloodstream stimulates monocytes/macrophages which once activated produce and release cytokines, nitric oxide and other mediators that induce systemic inflammation, endothelial damage, organ dysfunction, hypotension (shock and MOF.The aim of this study is to evaluate the usefulness of a quantitative test for the dosage of endotoxin to determine the risk of severe Gram-negative sepsis. Materials and methods. In the period January 2009 - June 2011 we performed 897 tests for 765 patients, mostly coming from the emergency room and intensive care, of which 328 (43% women (mean age 53 and 437 (57% male (mean age 49. Fifty-nine patients, no statistically significant difference in sex, were monitored by an average of two determinations of EA.All patients had procalcitonin values significantly altered.The kit used was EAA (Endotoxin Activity Assay Estor Company, Milan, which has three ranges of endotoxin activity (EA: low risk of sepsis if <0.40 units, medium if between 0.40 and 0.59; high if 0.60. Results. 78 out of 765 patients (10% had a low risk, 447 (58% a medium risk and 240 (32% a high risk.The dosage of EA, combined with that of procalcitonin, has allowed a more targeted antibiotic therapy. Six patients in serious clinical conditions were treated by direct hemoperfusion with Toraymyxin, a device comprising a housing containing a fiber polypropylene and polystyrene with surface-bound polymyxin B, an antibiotic that removes bacterial endotoxins from the blood. Conclusions.The test is useful in risk stratification as well as Gram negative sepsis, to set and monitor targeted therapies, also based on the neutralization of endotoxin.

  15. Role of radiation embrittlement in reactor vessel integrity assessment

    International Nuclear Information System (INIS)

    Marston, T.U.; Chexal, V.K.; Wyckoff, M.

    1982-01-01

    Reactor vessel integrity calculations are complex. The effect of radiation embrittlement on vessel material properties is a very important aspect of any vessel integrity evaluation. The importance of realistic (based on surveillance capsule results) rather than conservative estimates of the material properties (based on regulatory curves) cannot be overestimated. It is also important to make realistic thermal hydraulic and system operations assumptions. In addition, use of actual flaw sizes from in-service inspections (versus hypothetical flaw size selection) will promote realism. Important research results exist that need to be incorporated into the regulatory process. The authors believe results from current research and development efforts will demonstrate that, with reasonable assumptions and best estimate calculations, the safety of even the older reactor vessels with high copper content welds can be assured over their design lifetimes without the need for major fixes. The utilities, through EPRI and the vendors, have dedicated a significant effort to solving the pressurized thermal shock problem

  16. Status of readout integrated circuits for radiation detector

    International Nuclear Information System (INIS)

    Moon, B. S.; Hong, S. B.; Cheng, J. E. and others

    2001-09-01

    In this report, we describe the current status of readout integrated circuits developed for radiation detectors, along with new technologies being applied to this field. The current status of ASCIC chip development related to the readout electronics is also included in this report. Major sources of this report are from product catalogs and web sites of the related industries. In the field of semiconductor process technology in Korea, the current status of the multi-project wafer(MPW) of IDEC, the multi-project chip(MPC) of ISRC and other domestic semiconductor process industries is described. In the case of other countries, the status of the MPW of MOSIS in USA and the MPW of EUROPRACTICE in Europe is studied. This report also describes the technologies and products of readout integrated circuits of industries worldwide

  17. Integrated evaluation of radiative heating systems for residential buildings

    International Nuclear Information System (INIS)

    Anastaselos, Dimitrios; Theodoridou, Ifigeneia; Papadopoulos, Agis M.; Hegger, Manfred

    2011-01-01

    Based on the need to reduce CO 2 emissions and minimize energy dependency, the EU Member States have set ambitious energy policies goals and have developed respective, specific regulations, in order to improve the energy performance of the building sector. Thus, specific measures regarding the buildings' envelope, the use of efficient HVAC technologies and the integration of renewable energy systems are being constantly studied and promoted. The effective combination of these three main aspects will consequently result in maximum energy efficiency. Germany has played a key role in this development, with intensive work focusing in the improvement of the energy behaviour of the residential building stock. In this paper, the use of radiative heating systems placing special emphasis on infrared is being studied as part of the energy renovation of residential buildings from the 1970's. This is done by applying an integrated assessment model to evaluate specific interventions regarding the improvement of the energy behaviour of the buildings' envelope and the use of radiative heating systems, based on a thorough Life Cycle Analysis according to criteria of energy, economic and environmental performance, as well as thermal comfort. -- Highlights: → Assessment of energy, economic and environmental performance of heating systems. → Life Cycle Analysis in combination with the quality of thermal comfort. → Effectiveness of interventions in already partially insulated buildings.

  18. Study on Pyroelectric Harvesters Integrating Solar Radiation with Wind Power

    Directory of Open Access Journals (Sweden)

    Chun-Ching Hsiao

    2015-07-01

    Full Text Available Pyroelectric harvesters use temperature fluctuations to generate electrical outputs. Solar radiation and waste heat are rich energy sources that can be harvested. Pyroelectric energy converters offer a novel and direct energy-conversion technology by transforming time-dependent temperatures directly into electricity. Moreover, the great challenge for pyroelectric energy harvesting lies in finding promising temperature variations or an alternating thermal loading in real situations. Hence, in this article, a novel pyroelectric harvester integrating solar radiation with wind power by the pyroelectric effect is proposed. Solar radiation is a thermal source, and wind is a dynamic potential. A disk generator is used for harvesting wind power. A mechanism is considered to convert the rotary energy of the disk generator to drive a shutter for generating temperature variations in pyroelectric cells using a planetary gear system. The optimal period of the pyroelectric cells is 35 s to harvest the stored energy, about 70 μJ, while the rotary velocity of the disk generator is about 31 RPM and the wind speed is about 1 m/s. In this state, the stored energy acquired from the pyroelectric harvester is about 75% more than that from the disk generator. Although the generated energy of the proposed pyroelectric harvester is less than that of the disk generator, the pyroelectric harvester plays a complementary role when the disk generator is inactive in situations of low wind speed.

  19. Clinical comparison of high-speed rare-earth screen and par-speed screen for diagnostic efficacy and radiation dosage

    International Nuclear Information System (INIS)

    Robinson, T.; Becker, J.A.; Olson, A.P.

    1982-01-01

    One hundred patients underwent excretory urography and a comparison was made of ten-minute, well-collimated images that were obtained with both par-speed and rare-earth screens, the latter being 6.5 times faster than the par-speed calcium tungstate screens. Radiation dose was greatly reduced with the rare-earth screens. There were fewer inferior examinations, even though fine detail was imaged poorly, and there was a slightly increased quantum mottle, which was only a minor problem at this low 65 kVp. Since quantum mottle increases with kVp, however, our results are not applicable to higher kVp examinations. Despite reduced detail and increased mottle, the overall image quality obtained with the rare-earth screen was superior to the image quality obtained with the par-speed screen

  20. On an integral equation arising in the transport of radiation through a slab involving internal reflection

    International Nuclear Information System (INIS)

    Williams, M.M.R.

    2005-01-01

    The integral equation derived by Nieuwenhuizen and Luck for transmission of radiation through an optically thick diffusive medium is reconsidered in the light of radiative transfer theory and extended to slabs of arbitrary thickness. (author)

  1. Method of radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Hodes, L.

    1976-01-01

    A technique of radiation therapy treatment planning designed to allow the assignment of dosage limits directly to chosen points in the computer-displayed cross-section of the patient. These dosage limits are used as constraints in a linear programming attempt to solve for beam strengths, minimizing integral dosage. If a feasible plan exists, the optimized plan will be displayed for approval as an isodose pattern. If there is no feasible plan, the operator/therapist can designate some of the point dosage constraints as ''relaxed.'' Linear programming will then optimize for minimum deviation at the relaxed points. This process can be iterated and new points selected until an acceptable plan is realized. In this manner the plan is optimized for uniformity as well as overall low dosage. 6 claims, 6 drawing figures

  2. Proposal to integrate the service on radiation hygiene at the primary health care services for workers exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Frometa Suarez, Ileana; Lopez Pumar, Georgina; Gonzalez Amil, Melva

    1998-01-01

    The National Health System implemented in the last few years a new pattern of primary attention for workers by creating doctors offices in work centers. At the same time, the Ministry of Public Health (MINSAP) carries the medical surveillance of the staff exposed to ionizing radiation. This work proposes a program to integrate the consulting room on radiation hygiene to primary health care services for workers that work with ionizing radiation sources, aiming to ameliorate and improve them

  3. Determining S-1 dosage at hospitals prioritizing cancer chemotherapy

    International Nuclear Information System (INIS)

    Morimoto, Shigefumi; Kitada, Noriaki; Anami, Setsuko

    2008-01-01

    Although it is recommended that the standard S-1 dosage should be based on how large the body surface area is, an on-site setting of the appropriate dosage is often lower than the standard one, depending on the individual's condition and considering possible side effects and so, on. Here, we investigated usage conditions for S-1 as a part of field training for expert pharmacists at our hospital that performs total clinical treatments. Decreases in dosage per day for elderly patients were although the standard dosage is generally determined according to the amount of a patient's body surface. We conducted a retrospective survey with a total 90 patients by creating a tree-diagram to identify a reduction standard. It was found that the S-1 dosage was decreased when there were side effects, aggravation in performance status, decrease in kidney function, old age, combined injection chemotherapy, and a decrease in radiation therapy performance. The dosage decreases without such medical reasons were seen in only 4 of the 90 patients. At hospitals giving priority to chemotherapy, it became clear that appropriate treatment was promoted by decreasing. The individual target dosage on the basis of daily medical examination. (author)

  4. Integration of gene dosage and gene expression in non-small cell lung cancer, identification of HSP90 as potential target.

    Directory of Open Access Journals (Sweden)

    Mariëlle I Gallegos Ruiz

    Full Text Available BACKGROUND: Lung cancer causes approximately 1.2 million deaths per year worldwide, and non-small cell lung cancer (NSCLC represents 85% of all lung cancers. Understanding the molecular events in non-small cell lung cancer (NSCLC is essential to improve early diagnosis and treatment for this disease. METHODOLOGY AND PRINCIPAL FINDINGS: In an attempt to identify novel NSCLC related genes, we performed a genome-wide screening of chromosomal copy number changes affecting gene expression using microarray based comparative genomic hybridization and gene expression arrays on 32 radically resected tumor samples from stage I and II NSCLC patients. An integrative analysis tool was applied to determine whether chromosomal copy number affects gene expression. We identified a deletion on 14q32.2-33 as a common alteration in NSCLC (44%, which significantly influenced gene expression for HSP90, residing on 14q32. This deletion was correlated with better overall survival (P = 0.008, survival was also longer in patients whose tumors had low expression levels of HSP90. We extended the analysis to three independent validation sets of NSCLC patients, and confirmed low HSP90 expression to be related with longer overall survival (P = 0.003, P = 0.07 and P = 0.04. Furthermore, in vitro treatment with an HSP90 inhibitor had potent antiproliferative activity in NSCLC cell lines. CONCLUSIONS: We suggest that targeting HSP90 will have clinical impact for NSCLC patients.

  5. Automatic identification and normalization of dosage forms in drug monographs

    Science.gov (United States)

    2012-01-01

    Background Each day, millions of health consumers seek drug-related information on the Web. Despite some efforts in linking related resources, drug information is largely scattered in a wide variety of websites of different quality and credibility. Methods As a step toward providing users with integrated access to multiple trustworthy drug resources, we aim to develop a method capable of identifying drug's dosage form information in addition to drug name recognition. We developed rules and patterns for identifying dosage forms from different sections of full-text drug monographs, and subsequently normalized them to standardized RxNorm dosage forms. Results Our method represents a significant improvement compared with a baseline lookup approach, achieving overall macro-averaged Precision of 80%, Recall of 98%, and F-Measure of 85%. Conclusions We successfully developed an automatic approach for drug dosage form identification, which is critical for building links between different drug-related resources. PMID:22336431

  6. Solar Radiation Research Laboratory | Energy Systems Integration Facility |

    Science.gov (United States)

    Solar Radiation Research Laboratory (SRRL) has been collecting continuous measurements of basic solar continuous operation. More than 75 instruments contribute to the Baseline Measurement System by recording

  7. Gonadal dosage during hip dysplasia radiography in the dog.

    Science.gov (United States)

    Wood, A K; Reynolds, K M; Leith, I S; Burns, P A

    1977-01-01

    Thermoluminescent dosemeters were used to estimate gonadal dosage during hip dysplasia radiography of labrador retriever dogs. The mean radiation dose to the unshielded testes was 100 millirad (mrad) and the estimated dose to the shielded testes was 9 mrad. It was considered unnecessary to shield the ovaries.

  8. Fractional integration and radiative transfer in a multifractal atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Naud, C.; Schertzer, D. [Universite Pierre et Marie Curie, Paris (France); Lovejoy, S. [McGill Univ., Montreal (Canada)

    1996-04-01

    Recently, Cess et al. (1995) and Ramathan et al. (1995) cited observations which exhibit an anomalous absorption of cloudy skies in comparison with the value predicted by usual models and which thus introduce large uncertainties for climatic change assessments. These observation raise questions concerning the way general circulation models have been tuned for decades, relying on classical methods, of both radiative transfer and dynamical modeling. The observations also tend to demonstrate that homogeneous models are simply not relevant in relating the highly variable properties of clouds and radiation fields. However smoothed, the intensity of cloud`s multi-scattered radiation fields reflect this extreme variability.

  9. Radiation chemistry - extravaganza or an integral component of radiation processing of food

    International Nuclear Information System (INIS)

    Simic, M.G.; DeGraff, E.

    1983-01-01

    The role of radiation chemistry in radiation processing of foods is discussed in detail. A few examples demonstrating the relevance of the radiation chemistry of model systems to food-irradiation technology are given. The importance of irradiation parameters such as dose, dose rate, temperature, atmosphere, physical state and additives in achieving acceptable and high quality of irradiated foods are emphasized. A few examples of radiation-induced free radical reactions in model compounds relevant to foods are also discussed. (author)

  10. Dosimetry as an integral part of radiation processing

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1999-01-01

    Different connections between high-dose dosimetry and radiation processing are discussed. Radiation processing cannot be performed without proper dosimetry. Accurate high dose and high dose rate dosimetry exhibits several aspects: first of all it is the preservation of the quality of the product, then fulfillment of legal aspects and last but not the least the safety of processing. Further, seldom discussed topics are as follow: dosimetric problems occurring with double-side EB irradiations, discussed in connection with the deposition of electric charge during electron beam irradiation. Although dosimetry for basic research and for medical purposes are treated here only shortly, some conclusions reached from these fields are considered in dosimetry for radiation processing. High-dose dosimetry of radiation has become a separate field, with many papers published every year, but applied dosimetric projects are usually initiated by a necessity of particular application. (author)

  11. ALARA and an integrated approach to radiation protection

    International Nuclear Information System (INIS)

    Hendee, W.R.; Edwards, F.M.

    1986-01-01

    Exposures of individuals to ionizing radiation have been restricted for many years by a number of guidelines and rules developed by various advisory and regulatory groups. Accompanying these restrictions has been an evolving principle that exposures to individuals and groups should be kept as low as reasonably achievable (ALARA), consistent with provision of the benefits of radiation use to society. Although the ALARA concept is a laudable goal in principle, its implementation in a clinical facility has not been a straightforward process. Problems of implementing ALARA have been confounded further by the efforts of regulatory agencies to incorporate the ALARA concept into regulations governing radiation exposures. To facilitate the implementation of ALARA as a workable construct in a clinical facility, guidelines are needed for its application to both individual and collective exposures to radiation. The provision of such guidelines, including action and inaction levels for both individual and collective exposures, are presented here

  12. Sequential circuit design for radiation hardened multiple voltage integrated circuits

    Science.gov (United States)

    Clark, Lawrence T [Phoenix, AZ; McIver, III, John K.

    2009-11-24

    The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

  13. Integration of Radiation-Hard Magnetic Random Access Memory with CMOS ICs

    CERN Document Server

    Cerjan, C J

    2000-01-01

    The research undertaken in this LDRD-funded project addressed the joint development of magnetic material-based nonvolatile, radiation-hard memory cells with Sandia National Laboratory. Specifically, the goal of this project was to demonstrate the intrinsic radiation-hardness of Giant Magneto-Resistive (GMR) materials by depositing representative alloy combinations upon radiation-hardened silicon-based integrated circuits. All of the stated goals of the project were achieved successfully. The necessary films were successfully deposited upon typical integrated circuits; the materials retained their magnetic field response at the highest radiation doses; and a patterning approach was developed that did not degrade the as-fabricated properties of the underlying circuitry. These results establish the feasibility of building radiation-hard magnetic memory cells.

  14. Positron emission tomography in pediatric radiation oncology: integration in the treatment-planning process

    International Nuclear Information System (INIS)

    Krasin, M.J.; Hudson, M.M.; Kaste, S.C.

    2004-01-01

    The application of PET imaging to pediatric radiation oncology allows new approaches to targeting and selection of radiation dose based not only on the size of a tumor, but also on its metabolic activity. In order to integrate PET into treatment planning for radiation oncology, logistical issues regarding patient setup, image fusion, and target selection must be addressed. Through prospective study, the role of PET in pediatric malignancies will be established for diagnosis, treatment, and surveillance. To explore the potential role of PET and its incorporation into treatment planning in pediatric radiation oncology, an example case of pediatric Hodgkin's disease is discussed. (orig.)

  15. Integrated Worker Radiation Dose Assessment for the K Basins

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report documents an assessment of the radiation dose workers at the K Basins are expected to receive in the process of removing spent nuclear fuel from the storage basins. The K Basins (K East and K West) are located in the Hanford 100K Area

  16. Radiation effects on integrated circuits used in high energy research

    International Nuclear Information System (INIS)

    Kanofsky, A.S.; Yost, B.; Farr, W.

    1990-01-01

    The authors report here on radiation effects on two amplifiers used in high energy experiments. These are standard devices that are produced by LeCroy. They describe each of the devices and the experimental techniques. Finally, they present and discuss the results of the measurements. 5 figs

  17. Emergence of Integrated Urology-Radiation Oncology Practices in the State of Texas

    International Nuclear Information System (INIS)

    Jhaveri, Pavan M.; Sun Zhuyi; Ballas, Leslie; Followill, David S.; Hoffman, Karen E.; Jiang Jing; Smith, Benjamin D.

    2012-01-01

    Purpose: Integrated urology-radiation oncology (RO) practices have been advocated as a means to improve community-based prostate cancer care by joining urologic and radiation care in a single-practice environment. However, little is known regarding the scope and actual physical integration of such practices. We sought to characterize the emergence of such practices in Texas, their extent of physical integration, and their potential effect on patient travel times for radiation therapy. Methods and Materials: A telephone survey identified integrated urology-RO practices, defined as practices owned by urologists that offer RO services. Geographic information software was used to determine the proximity of integrated urology-RO clinic sites with respect to the state's population. We calculated patient travel time and distance from each integrated urology-RO clinic offering urologic services to the RO treatment facility owned by the integrated practice and to the nearest nonintegrated (independent) RO facility. We compared these times and distances using the Wilcoxon-Mann-Whitney test. Results: Of 229 urology practices identified, 12 (5%) offered integrated RO services, and 182 (28%) of 640 Texas urologists worked in such practices. Approximately 53% of the state population resides within 10 miles of an integrated urology-RO clinic site. Patients with a diagnosis of prostate cancer at an integrated urology-RO clinic site travel a mean of 19.7 miles (26.1 min) from the clinic to reach the RO facility owned by the integrated urology-RO practice vs 5.9 miles (9.2 min) to reach the nearest nonintegrated RO facility (P<.001). Conclusions: Integrated urology-RO practices are common in Texas and are generally clustered in urban areas. In most integrated practices, the urology clinics and the integrated RO facilities are not at the same location, and driving times and distances from the clinic to the integrated RO facility exceed those from the clinic to the nearest

  18. Integral and Lagrangian simulations of particle and radiation transport in plasma

    International Nuclear Information System (INIS)

    Christlieb, A J; Hitchon, W N G; Lawler, J E; Lister, G G

    2009-01-01

    Accurate integral and Lagrangian models of transport in plasmas, in which the models reflect the actual physical behaviour as closely as possible, are presented. These methods are applied to the behaviour of particles and photons in plasmas. First, to show how these types of models arise in a wide range of plasma physics applications, an application to radiation transport in a lighting discharge is given. The radiation transport is solved self-consistently with a model of the discharge to provide what are believed to be very accurate 1D simulations of fluorescent lamps. To extend these integral methods to higher dimensions is computationally very costly. The wide utility of 'treecodes' in solving massive integral problems in plasma physics is discussed, and illustrated in modelling vortex formation in a Penning trap, where a remarkably detailed simulation of vortex formation in the trap is obtained. Extension of treecode methods to other integral problems such as radiation transport is under consideration.

  19. Technique for selection of transient radiation-hard junction-isolated integrated circuits

    International Nuclear Information System (INIS)

    Crowley, J.L.; Junga, F.A.; Stultz, T.J.

    1976-01-01

    A technique is presented which demonstrates the feasibility of selecting junction-isolated integrated circuits (JI/ICS) for use in transient radiation environments. The procedure guarantees that all PNPN paths within the integrated circuit are identified and describes the methods used to determine whether the paths represent latchup susceptible structures. Two examples of the latchup analysis are given involving an SSI and an LSI bipolar junction-isolated integrated circuit

  20. An integrated framework for effective reduction of occupational radiation exposure in a nuclear power plant

    International Nuclear Information System (INIS)

    Joo, Hyun Moon; Hak, Soo Kim; Young, Ho Cho; Chang, Sun Kang

    1998-01-01

    For effective reduction of occupational radiation exposure in a nuclear power plant, it is necessary to identify repetitive high radiation jobs during maintenance and refueling operation and comprehensively assess them. An integrated framework for effective reduction of occupational radiation exposure is proposed in this study. The framework consists of three parts; data collection, statistical analysis, and ALARA findings. A PC-based database program, INSTORE, is used for data collection and reduction, and the Rank Sum Method is used in identifying high radiation jobs. As a case study, the data accumulated in Kori Units 3 and 4 have been analyzed. The results of this study show that the radiation job classifications of SG related work have much effect on annual ORE collective dose in Kori Units 3 and 4. As an example of ALARA findings, hence, the improvements for the radiation job classifications of SG related work are summarized

  1. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  2. A study of radiation hardness screening techniques of integrated circuits

    International Nuclear Information System (INIS)

    Wang Xuli

    2002-01-01

    The principle and operational procedure of Integrated Circuits (ICs) screening with irradiation-and-anneal and multicomponent regression analysis are discussed. The key technology, advantages and shortcomings of the two methods are described in contrast, and some advices are given with the state-of-the-art of the screening technology

  3. A tunable integrated system to simulate colder stellar radiation

    Science.gov (United States)

    Erculiani, Marco S.; Claudi, Riccardo; Barbisan, Diego; Giro, Enrico; Bonato, Matteo; Cocola, Lorenzo; Farisato, Giancarlo; Meneghini, Metteo; Poletto, Luca; Salasnich, Bernardo; Trivellin, Nicola

    2015-09-01

    In the last years, a lot of extrasolar planets have been discovered in any direction of the Galaxy. More interesting, some of them have been found in the habitable zone of their host stars. A large diversity of spectral type, from early types (A) to colder ones (M), is covered by the planetary system host stars. A lot of efforts are done in order to find habitable planets around M stars and indeed some habitable super earths were found. In this framework, "Atmosphere in a Test Tube", a project started at Astronomical observatory of Padua, simulates planetary environmental condition in order to understand how and how much the behavior of photosynthetic bacteria in different planetary/star scenarios can modify the planet atmosphere. The particular case of an habitable planet orbiting a M dwarf star is under study for the time being. The irradiation of an M star, due to its lower surface temperature is very different in quality and quantity by the irradiation of a star like our Sun. We would like to describe the study of feasibility of a new kind of tunable led stellarlight simulator capable to recreate the radiation spectrum of M type stars (but with the potential to be expanded even to F, G, K star spectra types) incident on the planet. The radiation source is a multiple LED matrix cooled by means of air fan technology. In order to endow it with modularity this device will be composed by a mosaic of circuit boards arranged in a pie-chart shape, on the surface of which will be welded the LEDs. This concept is a smart way in order to replace blown out pieces instead of changing the entire platform as well as implement the device with new modules suitable to reproduce other type of stars. The device can be driven by a PC to raise or lower the intensity of both each LED and the lamp, in order to simulate as close as possible a portion of the star spectrum. The wavelength intervals overlap the limits of photosynthetic pigment absorption range (280-850 nm), while the

  4. Predictions of integrated circuit serviceability in space radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Khamidullina, N.M.; Kuznetsov, N.V.; Pichkhadze, K.M.; Popov, V.D

    1999-10-01

    The present paper suggests an approach to estimating and predicting the serviceability of on-board electronic equipment. It is based on the postulates of the reliability theory and accounts for total-dose and single-event radiation effects as well as other exterior destabilizing factors. The methods of determination of failure and upset rates for CMOS devices are considered. The probability of non-failure operation of a two CMOS RAM is calculated along the whole trajectory of the 'Solar Probe' spacecraft.

  5. An Integrated Cloud-Aerosol-Radiation Product Using CERES, MODIS, CALIPSO and CloudSat Data

    Science.gov (United States)

    Sun-Mack, S.; Gibson, S.; Chen, Y.; Wielicki, B.; Minnis, P.

    2006-12-01

    The goal of this paper is to provide the first integrated data set of global vertical profiles of aerosols, clouds, and radiation using the combined NASA A-Train data from Aqua CERES and MODIS, CALIPSO, and CloudSat. All of these instruments are flying in formation as part of the Aqua Train, or A-Train. This paper will present the preliminary results of merging aerosol and cloud data from the CALIPSO active lidar, cloud data from CloudSat, integrated column aerosol and cloud data from the MODIS CERES analyses, and surface and top-of-atmosphere broadband radiation fluxes from CERES. These new data will provide unprecedented ability to test and improve global cloud and aerosol models, to investigate aerosol direct and indirect radiative forcing, and to validate the accuracy of global aerosol, cloud, and radiation data sets especially in polar regions and for multi-layered cloud conditions.

  6. Numerical simulation and experimental research of the integrated high-power LED radiator

    Science.gov (United States)

    Xiang, J. H.; Zhang, C. L.; Gan, Z. J.; Zhou, C.; Chen, C. G.; Chen, S.

    2017-01-01

    The thermal management has become an urgent problem to be solved with the increasing power and the improving integration of the LED (light emitting diode) chip. In order to eliminate the contact resistance of the radiator, this paper presented an integrated high-power LED radiator based on phase-change heat transfer, which realized the seamless connection between the vapor chamber and the cooling fins. The radiator was optimized by combining the numerical simulation and the experimental research. The effects of the chamber diameter and the parameters of fin on the heat dissipation performance were analyzed. The numerical simulation results were compared with the measured values by experiment. The results showed that the fin thickness, the fin number, the fin height and the chamber diameter were the factors which affected the performance of radiator from primary to secondary.

  7. A difference quotient-numerical integration method for solving radiative transfer problems

    International Nuclear Information System (INIS)

    Ding Peizhu

    1992-01-01

    A difference quotient-numerical integration method is adopted to solve radiative transfer problems in an anisotropic scattering slab medium. By using the method, the radiative transfer problem is separated into a system of linear algebraic equations and the coefficient matrix of the system is a band matrix, so the method is very simple to evaluate on computer and to deduce formulae and easy to master for experimentalists. An example is evaluated and it is shown that the method is precise

  8. Computation of the radiation Q of dielectric-loaded electrically small antennas in integral equation formulations

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    2016-01-01

    A new technique for estimating the impedance frequency bandwidth of electrically small antennas loaded with magneto-dielectric material from a single-frequency simulation in a surface integral equation solver is presented. The estimate is based on the inverse of the radiation Q computed using newly...... derived expressions for the stored energy and the radiated power of arbitrary coupled electric and magnetic currents in free space....

  9. Directional radiation of Babinet-inverted optical nanoantenna integrated with plasmonic waveguide

    Science.gov (United States)

    Kim, Jineun; Roh, Young-Geun; Cheon, Sangmo; Jeong Kim, Un; Hwang, Sung Woo; Park, Yeonsang; Lee, Chang-Won

    2015-07-01

    We present a Babinet-inverted optical nanoantenna integrated with a plasmonic waveguide. Using an integrated nanoantenna, we can couple the plasmon guide mode in a metal-insulator-metal (MIM) structure into the resonant antenna feed directly. The resonantly excited feed slot then radiates to free space and generates a magnetic dipole-like far-field pattern. The coupling efficiency of the integrated nanoantenna is calculated as being approximately 19% using a three-dimensional finite-difference time-domain (3D FDTD) simulation. By adding an auxiliary groove structure along with the feed, the radiation direction can be controlled similar to an optical Yagi-Uda antenna. We also determine, both theoretically and experimentally, that groove depth plays a significant role to function groove structure as a reflector or a director. The demonstrated Babinet-inverted optical nanoantenna integrated with a plasmonic waveguide can be used as a “plasmonic via” in plasmonic nanocircuits.

  10. Rock Burst Monitoring by Integrated Microseismic and Electromagnetic Radiation Methods

    Science.gov (United States)

    Li, Xuelong; Wang, Enyuan; Li, Zhonghui; Liu, Zhentang; Song, Dazhao; Qiu, Liming

    2016-11-01

    For this study, microseismic (MS) and electromagnetic radiation (EMR) monitoring systems were installed in a coal mine to monitor rock bursts. The MS system monitors coal or rock mass ruptures in the whole mine, whereas the EMR equipment monitors the coal or rock stress in a small area. By analysing the MS energy, number of MS events, and EMR intensity with respect to rock bursts, it has been shown that the energy and number of MS events present a "quiet period" 1-3 days before the rock burst. The data also show that the EMR intensity reaches a peak before the rock burst and this EMR intensity peak generally corresponds to the MS "quiet period". There is a positive correlation between stress and EMR intensity. Buckling failure of coal or rock depends on the rheological properties and occurs after the peak stress in the high-stress concentration areas in deep mines. The MS "quiet period" before the rock burst is caused by the heterogeneity of the coal and rock structures, the transfer of high stress into internal areas, locked patches, and self-organized criticality near the stress peak. This study increases our understanding of coal and rock instability in deep mines. Combining MS and EMR to monitor rock burst could improve prediction accuracy.

  11. Integral alpha and gamma radiation measurements in dwelling houses

    International Nuclear Information System (INIS)

    Paripas, B.; Takacs, S.; Somogyi, G.; Nikl, I.

    1984-01-01

    A solid state nuclear track detector method is applied to determine radon and total alpha-exposures (time integral of activity concentrations). The mathematical description of the method of measurement by a passive device equipped with two plastic sheets is presented. Measurements have been carried out in 88 houses over a five-month period and in 20 houses every season for a whole year. Simultaneously with the seasonal measurements of alpha-exposures, the gamma doses were also determined by means of TL dosemeters. The mean exposures due to thoron and its progeny have been estimated by statistical methods. A possible connection between the measured quantities and the lung cancer rates in two settlements were examined. (Author)

  12. Data integrity systems for organ contours in radiation therapy planning.

    Science.gov (United States)

    Shah, Veeraj P; Lakshminarayanan, Pranav; Moore, Joseph; Tran, Phuoc T; Quon, Harry; Deville, Curtiland; McNutt, Todd R

    2018-06-12

    The purpose of this research is to develop effective data integrity models for contoured anatomy in a radiotherapy workflow for both real-time and retrospective analysis. Within this study, two classes of contour integrity models were developed: data driven models and contiguousness models. The data driven models aim to highlight contours which deviate from a gross set of contours from similar disease sites and encompass the following regions of interest (ROI): bladder, femoral heads, spinal cord, and rectum. The contiguousness models, which individually analyze the geometry of contours to detect possible errors, are applied across many different ROI's and are divided into two metrics: Extent and Region Growing over volume. After analysis, we found that 70% of detected bladder contours were verified as suspicious. The spinal cord and rectum models verified that 73% and 80% of contours were suspicious respectively. The contiguousness models were the most accurate models and the Region Growing model was the most accurate submodel. 100% of the detected noncontiguous contours were verified as suspicious, but in the cases of spinal cord, femoral heads, bladder, and rectum, the Region Growing model detected additional two to five suspicious contours that the Extent model failed to detect. When conducting a blind review to detect false negatives, it was found that all the data driven models failed to detect all suspicious contours. The Region Growing contiguousness model produced zero false negatives in all regions of interest other than prostate. With regards to runtime, the contiguousness via extent model took an average of 0.2 s per contour. On the other hand, the region growing method had a longer runtime which was dependent on the number of voxels in the contour. Both contiguousness models have potential for real-time use in clinical radiotherapy while the data driven models are better suited for retrospective use. © 2018 The Authors. Journal of Applied Clinical

  13. Design of two digital radiation tolerant integrated circuits for high energy physics experiments data readout

    CERN Document Server

    Bonacini, Sandro

    2003-01-01

    High Energy Physics research (HEP) involves the design of readout electron- ics for its experiments, which generate a high radiation ¯eld in the detectors. The several integrated circuits placed in the future Large Hadron Collider (LHC) experiments' environment have to resist the radiation and carry out their normal operation. In this thesis I will describe in detail what, during my 10-months partic- ipation in the digital section of the Microelectronics group at CERN, I had the possibility to work on: - The design of a radiation-tolerant data readout digital integrated cir- cuit in a 0.25 ¹m CMOS technology, called \\the Kchip", for the CMS preshower front-end system. This will be described in Chapter 3. - The design of a radiation-tolerant SRAM integrated circuit in a 0.13 ¹m CMOS technology, for technology radiation testing purposes and fu- ture applications in the HEP ¯eld. The SRAM will be described in Chapter 4. All the work has carried out under the supervision and with the help of Dr. Kostas Klouki...

  14. The laboratory testing system for radiation rsistance investigations of integrated circuits

    International Nuclear Information System (INIS)

    Wronski, W.; Wislowski, J.

    1986-01-01

    In order to evaluate the radiation tolerance of integrated circuits MCY 7102 type /MOS RAM/ two devices were built: isotope arrangement for irradiation, and portable tester registering every error of storage block which consists of 32 IC's. Principle of operation and construction of this devices is described. Exemplary results of investigations are shown. (author)

  15. Prediction of ionizing radiation effects in integrated circuits using black-box models

    International Nuclear Information System (INIS)

    Williamson, P.W.

    1976-10-01

    A method is described which allows general black-box modelling of integrated circuits as distinct from the existing method of deriving the radiation induced response of the model from actual terminal measurements on the device during irradiation. Both digital and linear circuits are discussed. (author)

  16. Full control of far-field radiation via photonic integrated circuits decorated with plasmonic nanoantennas.

    Science.gov (United States)

    Sun, Yi-Zhi; Feng, Li-Shuang; Bachelot, Renaud; Blaize, Sylvain; Ding, Wei

    2017-07-24

    We theoretically develop a hybrid architecture consisting of photonic integrated circuit and plasmonic nanoantennas to fully control optical far-field radiation with unprecedented flexibility. By exploiting asymmetric and lateral excitation from silicon waveguides, single gold nanorod and cascaded nanorod pair can function as component radiation pixels, featured by full 2π phase coverage and nanoscale footprint. These radiation pixels allow us to design scalable on-chip devices in a wavefront engineering fashion. We numerically demonstrate beam collimation with 30° out of the incident plane and nearly diffraction limited divergence angle. We also present high-numerical-aperture (NA) beam focusing with NA ≈0.65 and vector beam generation (the radially-polarized mode) with the mode similarity greater than 44%. This concept and approach constitutes a designable optical platform, which might be a future bridge between integrated photonics and metasurface functionalities.

  17. Integrated simulation of continuous-scale and discrete-scale radiative transfer in metal foams

    Science.gov (United States)

    Xia, Xin-Lin; Li, Yang; Sun, Chuang; Ai, Qing; Tan, He-Ping

    2018-06-01

    A novel integrated simulation of radiative transfer in metal foams is presented. It integrates the continuous-scale simulation with the direct discrete-scale simulation in a single computational domain. It relies on the coupling of the real discrete-scale foam geometry with the equivalent continuous-scale medium through a specially defined scale-coupled zone. This zone holds continuous but nonhomogeneous volumetric radiative properties. The scale-coupled approach is compared to the traditional continuous-scale approach using volumetric radiative properties in the equivalent participating medium and to the direct discrete-scale approach employing the real 3D foam geometry obtained by computed tomography. All the analyses are based on geometrical optics. The Monte Carlo ray-tracing procedure is used for computations of the absorbed radiative fluxes and the apparent radiative behaviors of metal foams. The results obtained by the three approaches are in tenable agreement. The scale-coupled approach is fully validated in calculating the apparent radiative behaviors of metal foams composed of very absorbing to very reflective struts and that composed of very rough to very smooth struts. This new approach leads to a reduction in computational time by approximately one order of magnitude compared to the direct discrete-scale approach. Meanwhile, it can offer information on the local geometry-dependent feature and at the same time the equivalent feature in an integrated simulation. This new approach is promising to combine the advantages of the continuous-scale approach (rapid calculations) and direct discrete-scale approach (accurate prediction of local radiative quantities).

  18. Non-destructive screening method for radiation hardened performance of large scale integration

    International Nuclear Information System (INIS)

    Zhou Dong; Xi Shanbin; Guo Qi; Ren Diyuan; Li Yudong; Sun Jing; Wen Lin

    2013-01-01

    The space radiation environment could induce radiation damage on the electronic devices. As the performance of commercial devices is generally superior to that of radiation hardened devices, it is necessary to screen out the devices with good radiation hardened performance from the commercial devices and applying these devices to space systems could improve the reliability of the systems. Combining the mathematical regression analysis with the different physical stressing experiments, we investigated the non-destructive screening method for radiation hardened performance of the integrated circuit. The relationship between the change of typical parameters and the radiation performance of the circuit was discussed. The irradiation-sensitive parameters were confirmed. The pluralistic linear regression equation toward the prediction of the radiation performance was established. Finally, the regression equations under stress conditions were verified by practical irradiation. The results show that the reliability and accuracy of the non-destructive screening method can be elevated by combining the mathematical regression analysis with the practical stressing experiment. (authors)

  19. Hydraulic Modular Dosaging Systems for Machine Drives

    Directory of Open Access Journals (Sweden)

    A. J. Kotlobai

    2005-01-01

    Full Text Available The justified principle of making modular dosaging systems for positive-displacement multimotor hydraulic drives used in running gear and technological equipment of mobile construction, road and agricultural machines makes it possible to synchronize motion of running parts. The examples of the realization of modular dosaging systems and an algorithm of their operation are given in the paper.

  20. [Pharmaceutical advice concerning different pharmaceutical dosage forms].

    Science.gov (United States)

    Szakonyi, Gergely; Zelkó, Romána

    2010-01-01

    The present paper summarizes the commonly applied types of drug uptake and the pharmacists' advice concerning a certain dosage form. The manuscript also deals with the modified release dosage forms and their abbreviations in the name of the marketing authorized products.

  1. Integral Dose and Radiation-Induced Secondary Malignancies: Comparison between Stereotactic Body Radiation Therapy and Three-Dimensional Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Stefano G. Masciullo

    2012-11-01

    Full Text Available The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID in stereotactic body radiation therapy (SBRT with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT, estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED on the target (BED = 76Gy10. Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05. Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002, secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001. This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

  2. Digital and conventional radiology techniques: comparison of dosage and costs

    International Nuclear Information System (INIS)

    Arranza, L.; Albornoz, C. de

    1996-01-01

    To compare the radiation dosage and costs in conventional and digital technologies. The study dealt with transverse sections. The dosage applied with conventional technology was measured in 254 patients who intertwined 402 explorations of 6 anatomic regions in 4 Radiodiagnostic Services. The dosage applied with digital technology was measured in 57 patients who underwent 95 explorations of the same anatomic region in one Radiodiagnostic Service. The costs of the 6 types of conventional and digital explorations performed were calculated for two Radiodiagnostic Service. The doses administered (mGy) using convectional/digital technology were as follows: chest PA 0.2/0.1; chest LAT 0.7/0.3; breast CC 7.0/8.4; breast LAT 7.0/7.8; breast OB 7.0/10.5; cervical spine AP 9.6/9.0; cervical spine LAT 21.9/29.6; pelvis AP 7.3/7.1; plain abdominal 6.5/2.2. The costs incurred (1992 pesetas) with the convectional/digital technologies: chest AP and LAT 1,393/2,973; portable chest 2,027/3,714; mammography 2,357/3,486; phlebography 12,718/14,023; hysterosalpingography 4,876/6,701; bone scientigraphy 1,633/2,839. Compared with conventional technology, digital imaging reduces the radiation doses received by the patients, except in the case of mammography. The costs associated with the use of digital technology are greater than those incurred with conventional technology, mainly due to the costs of amortization. the use of digital technology is more justified when: 1) it is very necessary to reduce the dosage; 2) studies of chest and abdomen predominant; 3) the volume of utilization is high; 4) staff management is flexible , and 5) the cost of purchasing the equipment is lower. (Author) 10 refs

  3. SEM analysis of ionizing radiation effects in linear integrated circuits. [Scanning Electron Microscope

    Science.gov (United States)

    Stanley, A. G.; Gauthier, M. K.

    1977-01-01

    A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.

  4. Australia's proactive approach to radiation protection of the environment: how integrated is it with radiation protection of humans?

    Science.gov (United States)

    Hirth, G A; Grzechnik, M; Tinker, R; Larsson, C M

    2018-01-01

    Australia's regulatory framework has evolved over the past decade from the assumption that protection of humans implies protection of the environment to the situation now where radiological impacts on non-human species (wildlife) are considered in their own right. In an Australian context, there was a recognised need for specific national guidance on protection of non-human species, for which the uranium mining industry provides the major backdrop. National guidance supported by publications of the Australian Radiation Protection and Nuclear Safety Agency (Radiation Protection Series) provides clear and consistent advice to operators and regulators on protection of non-human species, including advice on specific assessment methods and models, and how these might be applied in an Australian context. These approaches and the supporting assessment tools provide a mechanism for industry to assess and demonstrate compliance with the environmental protection objectives of relevant legislation, and to meet stakeholder expectations that radiological protection of the environment is taken into consideration in accordance with international best practice. Experiences from the past 5-10 years, and examples of where the approach to radiation protection of the environment has been well integrated or presented some challenges will be discussed. Future challenges in addressing protection of the environment in existing exposure situations will also be discussed.

  5. Synthetic radiation diagnostics in PIConGPU. Integrating spectral detectors into particle-in-cell codes

    Energy Technology Data Exchange (ETDEWEB)

    Pausch, Richard; Burau, Heiko; Huebl, Axel; Steiniger, Klaus [Helmholtz-Zentrum Dresden-Rossendorf (Germany); Technische Universitaet Dresden (Germany); Debus, Alexander; Widera, Rene; Bussmann, Michael [Helmholtz-Zentrum Dresden-Rossendorf (Germany)

    2016-07-01

    We present the in-situ far field radiation diagnostics in the particle-in-cell code PIConGPU. It was developed to close the gap between simulated plasma dynamics and radiation observed in laser plasma experiments. Its predictive capabilities, both qualitative and quantitative, have been tested against analytical models. Now, we apply this synthetic spectral diagnostics to investigate plasma dynamics in laser wakefield acceleration, laser foil irradiation and plasma instabilities. Our method is based on the far field approximation of the Lienard-Wiechert potential and allows predicting both coherent and incoherent radiation spectrally from infrared to X-rays. Its capability to resolve the radiation polarization and to determine the temporal and spatial origin of the radiation enables us to correlate specific spectral signatures with characteristic dynamics in the plasma. Furthermore, its direct integration into the highly-scalable GPU framework of PIConGPU allows computing radiation spectra for thousands of frequencies, hundreds of detector positions and billions of particles efficiently. In this talk we will demonstrate these capabilities on resent simulations of laser wakefield acceleration (LWFA) and high harmonics generation during target normal sheath acceleration (TNSA).

  6. Integration of radiation protection in safety management: sharing best practices between radiation protection and other safety areas

    International Nuclear Information System (INIS)

    Kockerols, Pierre; Fessler, Andreas

    2008-01-01

    Full text: The Institute for Reference Materials and Measurements (IRMM) located in Geel is one of the seven institutes of the Joint Research Centre of the European Commission (EC, DG JRC). The institute was founded in 1960 as a nuclear research centre, but has gradually shifted its activities to also include 'non-nuclear' domains, mainly in the areas of food safety and environmental surveillance. As the activities on the IRMM site are currently quite diversified, they necessitate the operation of nuclear controlled areas, accelerators, as well as bio safety restricted areas and chemical laboratories. Therefore, the care for occupational health and safety and for environmental protection has to take into consideration various types of hazards and threats. Recently an integrated management system according to ISO-9001, ISO-14001 and OHSAS-18001 was implemented. The integrated system combines 'vertically' quality, occupational health and safety and environmental issues and covers 'horizontally' the nuclear, biological and chemical fields. The paper outlines how the radiation protection can be included in an overall health, safety and environmental management system. It will give various practical examples where synergies can be applied: 1-) the overall policy; 2-) The assessment and ranking of all risks and the identification, in a combined way, of the appropriate prevention measures; 3-) The planning and review of related actions; 4-) The monitoring, auditing and registration of anomalies and incidents and the definition of corrective actions; 5-) The training of personnel based on lessons learned from past experiences; 6-) The organisation of an internal emergency plan dealing with nuclear and non-nuclear hazards. Based on these examples, the benefits of having an integrated approach are commented. In addition, the paper will illustrate how the recent ICRP fundamental recommendations and more particularly some of the principles of radiation protection such as

  7. Low-cost sensor integrators for measuring the transmissivity of complex canopies to photosynthetically active radiation

    International Nuclear Information System (INIS)

    Newman, S.M.

    1985-01-01

    A system has been designed, tested and evaluated for measuring the transmissivities of complex canopies to photosynthetically active radiation (PAR). The system consists of filtered silicon photocells in cosine corrected mounts with outputs integrated by the use of chemical coulometers. The reading accumulated by the coulometers was taken electronically by the use of microcomputers. The low-cost sensor integrators, which do not require batteries, performed as expected and proved ideal for the study of agroforestry systems in remote areas. Information on the PAR transmissivity of a temperate agroforestry system in the form of an intercropped orchard is also presented. (author)

  8. Impact of late radiation effects on cancer survivor children: an integrative review

    International Nuclear Information System (INIS)

    Coura, Cibeli Fernandes; Modesto, Patrícia Cláudia; Coura, Cibeli Fernandes; Modesto, Patrícia Cláudia

    2016-01-01

    We aimed to identify the late effects of radiation exposure in pediatric cancer survivors. An integrated literature review was performed in the databases MEDLINE and LILACS and SciELO. Included were articles in Portuguese and English, published over the past 10 years, using the following keywords: “neoplasias/neoplasms” AND “radioterapia/radiotherapy” AND “radiação/radiation”. After analysis, 14 articles - published in nine well-known journals - met the inclusion criteria. The publications were divided into two categories: “Late endocrine effects” and “Late non-endocrine effects”. Considering the increased survival rates in children who had cancer, the impact of late effects of exposure to radiation during radiological examinations for diagnosis and treatment was analyzed. Childhood cancer survivors were exposed to several late effects and should be early and regularly followed up, even when exposed to low radiation doses

  9. Effects of plasma-deposited silicon nitride passivation on the radiation hardness of CMOS integrated circuits

    International Nuclear Information System (INIS)

    Clement, J.J.

    1980-01-01

    The use of plasma-deposited silicon nitride as a final passivation over metal-gate CMOS integrated circuits degrades the radiation hardness of these devices. The hardness degradation is manifested by increased radiation-induced threshold voltage shifts caused principally by the charging of new interface states and, to a lesser extent, by the trapping of holes created upon exposure to ionizing radiation. The threshold voltage shifts are a strong function of the deposition temperature, and show very little dependence on thickness for films deposited at 300 0 C. There is some correlation between the threshold voltage shifts and the hydrogen content of the PECVD silicon nitride films used as the final passivation layer as a function of deposition temperature. The mechanism by which the hydrogen contained in these films may react with the Si/SiO 2 interface is not clear at this point

  10. Impact of late radiation effects on cancer survivor children: an integrative review

    Energy Technology Data Exchange (ETDEWEB)

    Coura, Cibeli Fernandes; Modesto, Patrícia Cláudia [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Coura, Cibeli Fernandes; Modesto, Patrícia Cláudia [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2016-07-01

    We aimed to identify the late effects of radiation exposure in pediatric cancer survivors. An integrated literature review was performed in the databases MEDLINE and LILACS and SciELO. Included were articles in Portuguese and English, published over the past 10 years, using the following keywords: “neoplasias/neoplasms” AND “radioterapia/radiotherapy” AND “radiação/radiation”. After analysis, 14 articles - published in nine well-known journals - met the inclusion criteria. The publications were divided into two categories: “Late endocrine effects” and “Late non-endocrine effects”. Considering the increased survival rates in children who had cancer, the impact of late effects of exposure to radiation during radiological examinations for diagnosis and treatment was analyzed. Childhood cancer survivors were exposed to several late effects and should be early and regularly followed up, even when exposed to low radiation doses.

  11. Development of a construction and manufacturing techniques of complementary transistors for the radiation tolerant integrated circuits

    Directory of Open Access Journals (Sweden)

    Gorban A. N.

    2011-06-01

    Full Text Available The construction of vertical complementary transistors with the full dielectric isolation is developed, new technolo-gical processes of creation on their basis the radiation tolerant integrated circuits with parameters which provide low values of a leakage current along with the considerable values of a forward current and breakdown voltage at the information signals exchange frequency of about 500 kHz are developed.

  12. Data integration reveals key homeostatic mechanisms following low dose radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Tilton, Susan C.; Matzke, Melissa M. [Computational Biology and Bioinformatics, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Sowa, Marianne B.; Stenoien, David L.; Weber, Thomas J. [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Morgan, William F. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Waters, Katrina M., E-mail: katrina.waters@pnnl.gov [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99338 (United States)

    2015-05-15

    The goal of this study was to define pathways regulated by low dose radiation to understand how biological systems respond to subtle perturbations in their environment and prioritize pathways for human health assessment. Using an in vitro 3-D human full thickness skin model, we have examined the temporal response of dermal and epidermal layers to 10 cGy X-ray using transcriptomic, proteomic, phosphoproteomic and metabolomic platforms. Bioinformatics analysis of each dataset independently revealed potential signaling mechanisms affected by low dose radiation, and integrating data shed additional insight into the mechanisms regulating low dose responses in human tissue. We examined direct interactions among datasets (top down approach) and defined several hubs as significant regulators, including transcription factors (YY1, MYC and CREB1), kinases (CDK2, PLK1) and a protease (MMP2). These data indicate a shift in response across time — with an increase in DNA repair, tissue remodeling and repression of cell proliferation acutely (24–72 h). Pathway-based integration (bottom up approach) identified common molecular and pathway responses to low dose radiation, including oxidative stress, nitric oxide signaling and transcriptional regulation through the SP1 factor that would not have been identified by the individual data sets. Significant regulation of key downstream metabolites of nitrative stress was measured within these pathways. Among the features identified in our study, the regulation of MMP2 and SP1 was experimentally validated. Our results demonstrate the advantage of data integration to broadly define the pathways and networks that represent the mechanisms by which complex biological systems respond to perturbation. - Highlights: • Low dose ionizing radiation altered homeostasis in 3D skin tissue model. • Global gene/protein/metabolite data integrated using complementary statistical approaches • Time and location-specific change in matrix regulation

  13. A management system integrating radiation protection and safety supporting safety culture in the hospital

    International Nuclear Information System (INIS)

    Almen, A.; Lundh, C.

    2015-01-01

    Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system. The main experience from developing a management system is that it is possible to create a vast number of common policies and routines for the whole hospital, resulting in a cost-efficient system. One of the key benefits is the involvement of management at all levels, including the hospital director. Furthermore, a transparent system will involve staff throughout the organisation as well. A management system supports a common view on what should be done, who should do it and how the activities are reviewed. An integrated management system for radiation protection and safety includes key elements supporting a safety culture. (authors)

  14. Thermal management in MoS{sub 2} based integrated device using near-field radiation

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Jiebin [Department of Physics, National University of Singapore, Singapore 117546 (Singapore); Zhang, Gang, E-mail: zhangg@ihpc.a-star.edu.sg [Institute of High Performance Computing, A*STAR, Singapore 138632 (Singapore); Li, Baowen [Department of Mechanical Engineering, University of Colorado, Boulder, Colorado 80309 (United States)

    2015-09-28

    Recently, wafer-scale growth of monolayer MoS{sub 2} films with spatial homogeneity is realized on SiO{sub 2} substrate. Together with the latest reported high mobility, MoS{sub 2} based integrated electronic devices are expected to be fabricated in the near future. Owing to the low lattice thermal conductivity in monolayer MoS{sub 2}, and the increased transistor density accompanied with the increased power density, heat dissipation will become a crucial issue for these integrated devices. In this letter, using the formalism of fluctuation electrodynamics, we explored the near-field radiative heat transfer from a monolayer MoS{sub 2} to graphene. We demonstrate that in resonance, the maximum heat transfer via near-field radiation between MoS{sub 2} and graphene can be ten times higher than the in-plane lattice thermal conduction for MoS{sub 2} sheet. Therefore, an efficient thermal management strategy for MoS{sub 2} integrated device is proposed: Graphene sheet is brought into close proximity, 10–20 nm from MoS{sub 2} device; heat energy transfer from MoS{sub 2} to graphene via near-field radiation; this amount of heat energy then be conducted to contact due to ultra-high lattice thermal conductivity of graphene. Our work sheds light for developing cooling strategy for nano devices constructing with low thermal conductivity materials.

  15. Integrated cloud-aerosol-radiation product using CERES, MODIS, CALIPSO, and CloudSat data

    Science.gov (United States)

    Sun-Mack, Sunny; Minnis, Patrick; Chen, Yan; Gibson, Sharon; Yi, Yuhong; Trepte, Qing; Wielicki, Bruce; Kato, Seiji; Winker, Dave; Stephens, Graeme; Partain, Philip

    2007-10-01

    This paper documents the development of the first integrated data set of global vertical profiles of clouds, aerosols, and radiation using the combined NASA A-Train data from the Aqua Clouds and Earth's Radiant Energy System (CERES) and Moderate Resolution Imaging Spectroradiometer (MODIS), Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO), and CloudSat. As part of this effort, cloud data from the CALIPSO lidar and the CloudSat radar are merged with the integrated column cloud properties from the CERES-MODIS analyses. The active and passive datasets are compared to determine commonalities and differences in order to facilitate the development of a 3-dimensional cloud and aerosol dataset that will then be integrated into the CERES broadband radiance footprint. Preliminary results from the comparisons for April 2007 reveal that the CERES-MODIS global cloud amounts are, on average, 0.14 less and 0.15 greater than those from CALIPSO and CloudSat, respectively. These new data will provide unprecedented ability to test and improve global cloud and aerosol models, to investigate aerosol direct and indirect radiative forcing, and to validate the accuracy of global aerosol, cloud, and radiation data sets especially in polar regions and for multi-layered cloud conditions.

  16. Radiation induced currents in MRI RF coils: application to linac/MRI integration

    Science.gov (United States)

    Burke, B.; Fallone, B. G.; Rathee, S.

    2010-02-01

    The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integrated systems, the radiofrequency (RF) coils of MRI will be irradiated with radiation pulses from the linac. The effect of pulsed radiation on MRI radio frequency (RF) coils is not known and must be studied. The instantaneous radiation induced current (RIC) in two different MRI RF coils were measured and presented. The frequency spectra of the induced currents were calculated. Some basic characterization of the RIC was also done: isolation of the RF coil component responsible for RIC, dependence of RIC on dose rate, and effect of wax buildup placed on coil on RIC. Both the time and frequency characteristics of the RIC were seen to vary with the MRI RF coil used. The copper windings of the RF coils were isolated as the main source of RIC. A linear dependence on dose rate was seen. The RIC was decreased with wax buildup, suggesting an electronic disequilibrium as the cause of RIC. This study shows a measurable RIC present in MRI RF coils. This unwanted current could be possibly detrimental to the signal to noise ratio in MRI and produce image artifacts.

  17. CONCERT-'European Joint Programme for the Integration at Radiation Protection Research'; CONCERT-''European Joint Programme for the Integration at Radiation Protection Research''

    Energy Technology Data Exchange (ETDEWEB)

    Birschwilks, Mandy; Schmitt-Hannig, Annemarie [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). Internationale und Nationale Zusammenarbeit im Strahlenschutz; Jung, Thomas [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). Strahlenschutz und Gesundheit

    2016-08-01

    In 2009 the High Level Expert Group (HLEG) on low dose research recommended the development of a scientific platform for low dose radiation research. The foundation of MELODI (Multidisciplinary European Low Dose Initiative) occurred in 2010. In 2015 a new project on radiation protection research was established: CONCERT (European Joint Programme for the Integration at Radiation Protection Research). The aim is the coordination of the already existing scientific platforms MELODI (radiation effects and interactions), ALLIANCE (radioecology), NERIS (nuclear and radiological emergency protection) and EURADOS (radiation dosimetry). With CONCERT an efficient use of this infrastructure for research cooperation and transparency is intended.

  18. Radiation safety infrastructure in developing countries: a proactive approach for integrated and continuous improvement

    International Nuclear Information System (INIS)

    Mrabit, Khammar

    2008-01-01

    The International Atomic Energy Agency (the Agency) is authorized, by its statute, to establish or adopt safety standards for the protection of health and minimization of danger to life and property, and to provide for their application to its own operations as well as to operations under its control or supervision. The Agency has been assisting, since the mid 1960 's, its Member States through mainly its Technical Cooperation Programme (TCP) to improve their national radiation safety infrastructures. However up to the early nineties, assistance was specific and mostly ad hoc and did not systematically utilize an integrated and harmonized approach to achieving effective and sustainable national radiation safety infrastructures in Member States. An unprecedented and integrated international cooperative effort was launched by the Agency in 1994 to establish and/or upgrade the national radiation safety infrastructure in more than 90 countries within the framework of its TCP through the so-called Model project on upgrading radiation protection infrastructure. In this project proactive co-operation with Member States was used in striving towards achieving an effective and sustainable radiation safety infrastructure, compatible with the International basic safety standards for protection against ionizing radiation and for the safety of radiation sources (the BSS) and related standards. Extension to include compatibility with the guidance of the Code of Conduct on the Safety and Security of Radioactive Sources occurred towards the end of the Model Project in December 2004, and with the more recent ensuing follow up projects that started in 2005. The Model Project started with 5 countries in 1994 and finished with 91 countries in 2004. Up to the end of 2007 more than one hundred Member States had been participating in follow up projects covering six themes - namely: legislative and regulatory infrastructure; occupational radiation protection; radiation protection in

  19. Advances in solid dosage form manufacturing technology.

    Science.gov (United States)

    Andrews, Gavin P

    2007-12-15

    Currently, the pharmaceutical and healthcare industries are moving through a period of unparalleled change. Major multinational pharmaceutical companies are restructuring, consolidating, merging and more importantly critically assessing their competitiveness to ensure constant growth in an ever-more demanding market where the cost of developing novel products is continuously increasing. The pharmaceutical manufacturing processes currently in existence for the production of solid oral dosage forms are associated with significant disadvantages and in many instances provide many processing problems. Therefore, it is well accepted that there is an increasing need for alternative processes to dramatically improve powder processing, and more importantly to ensure that acceptable, reproducible solid dosage forms can be manufactured. Consequently, pharmaceutical companies are beginning to invest in innovative processes capable of producing solid dosage forms that better meet the needs of the patient while providing efficient manufacturing operations. This article discusses two emerging solid dosage form manufacturing technologies, namely hot-melt extrusion and fluidized hot-melt granulation.

  20. An integrated circuit/microsystem/nano-enhanced four species radiation sensor for inexpensive fissionable material detection

    Science.gov (United States)

    Waguespack, Randy Paul

    2011-12-01

    Small scale radiation detectors sensitive to alpha, beta, electromagnetic, neutron radiation are needed to combat the threat of nuclear terrorism and maintain national security. There are many types of radiation detectors on the market, and the type of detector chosen is usually determined by the type of particle to be detected. In the case of fissionable material, an ideal detector needs to detect all four types of radiation, which is not the focus of many detectors. For fissionable materials, the two main types of radiation that must be detected are gamma rays and neutrons. Our detector uses a glass or quartz scintillator doped with 10B nanoparticles to detect all four types of radiation particles. Boron-10 has a thermal neutron cross section of 3,840 barns. The interaction between the neutron and boron results in a secondary charge particle in the form of an alpha particle to be emitted, which is detectable by the scintillator. Radiation impinging on the scintillator matrix produces varying optical pulses dependent on the energy of the particles. The optical pulses are then detected by a photomultiplier (PM) tube, creating a current proportional to the energy of the particle. Current pulses from the PM tube are differentiated by on-chip pulse height spectroscopy, allowing for source discrimination. The pulse height circuitry has been fabricated with discrete circuits and designed into an integrated circuit package. The ability to replace traditional PM tubes with a smaller, less expensive photomultiplier will further reduce the size of the device and enhance the cost effectiveness and portability of the detector.

  1. Integration of a radiation biomarker into modeling of thyroid carcinogenesis and post-Chernobyl risk assessment.

    Science.gov (United States)

    Kaiser, Jan Christian; Meckbach, Reinhard; Eidemüller, Markus; Selmansberger, Martin; Unger, Kristian; Shpak, Viktor; Blettner, Maria; Zitzelsberger, Horst; Jacob, Peter

    2016-12-01

    Strong evidence for the statistical association between radiation exposure and disease has been produced for thyroid cancer by epidemiological studies after the Chernobyl accident. However, limitations of the epidemiological approach in order to explore health risks especially at low doses of radiation appear obvious. Statistical fluctuations due to small case numbers dominate the uncertainty of risk estimates. Molecular radiation markers have been searched extensively to separate radiation-induced cancer cases from sporadic cases. The overexpression of the CLIP2 gene is the most promising of these markers. It was found in the majority of papillary thyroid cancers (PTCs) from young patients included in the Chernobyl tissue bank. Motivated by the CLIP2 findings we propose a mechanistic model which describes PTC development as a sequence of rate-limiting events in two distinct paths of CLIP2-associated and multistage carcinogenesis. It integrates molecular measurements of the dichotomous CLIP2 marker from 141 patients into the epidemiological risk analysis for about 13 000 subjects from the Ukrainian-American cohort which were exposed below age 19 years and were put under enhanced medical surveillance since 1998. For the first time, a radiation risk has been estimated solely from marker measurements. Cross checking with epidemiological estimates and model validation suggests that CLIP2 is a marker of high precision. CLIP2 leaves an imprint in the epidemiological incidence data which is typical for a driver gene. With the mechanistic model, we explore the impact of radiation on the molecular landscape of PTC. The model constitutes a unique interface between molecular biology and radiation epidemiology. © The Author 2016. Published by Oxford University Press.

  2. Radiation effects at ISABELLE

    International Nuclear Information System (INIS)

    Sanger, P.A.; Danby, G.T.

    1975-01-01

    Shielding, radiation damage, and radiation heating at the planned ISABELLE storage rings were considered. Radiation shielding studies were reviewed and were found to be adequate for present day dosage limits. Radiation damage could be encountered in some extreme cases, but is not expected to limit the performance of the superconducting magnets. Experiments to study the effect of radiation heating on actual magnets are recommended

  3. The shaping and functional consequences of the dosage effect landscape in multiple myeloma.

    Science.gov (United States)

    Samur, Mehmet K; Shah, Parantu K; Wang, Xujun; Minvielle, Stéphane; Magrangeas, Florence; Avet-Loiseau, Hervé; Munshi, Nikhil C; Li, Cheng

    2013-10-02

    Multiple myeloma (MM) is a malignant proliferation of plasma B cells. Based on recurrent aneuploidy such as copy number alterations (CNAs), myeloma is divided into two subtypes with different CNA patterns and patient survival outcomes. How aneuploidy events arise, and whether they contribute to cancer cell evolution are actively studied. The large amount of transcriptomic changes resultant of CNAs (dosage effect) pose big challenges for identifying functional consequences of CNAs in myeloma in terms of specific driver genes and pathways. In this study, we hypothesize that gene-wise dosage effect varies as a result from complex regulatory networks that translate the impact of CNAs to gene expression, and studying this variation can provide insights into functional effects of CNAs. We propose gene-wise dosage effect score and genome-wide karyotype plot as tools to measure and visualize concordant copy number and expression changes across cancer samples. We find that dosage effect in myeloma is widespread yet variable, and it is correlated with gene expression level and CNA frequencies in different chromosomes. Our analysis suggests that despite the enrichment of differentially expressed genes between hyperdiploid MM and non-hyperdiploid MM in the trisomy chromosomes, the chromosomal proportion of dosage sensitive genes is higher in the non-trisomy chromosomes. Dosage-sensitive genes are enriched by genes with protein translation and localization functions, and dosage resistant genes are enriched by apoptosis genes. These results point to future studies on differential dosage sensitivity and resistance of pro- and anti-proliferation pathways and their variation across patients as therapeutic targets and prognosis markers. Our findings support the hypothesis that recurrent CNAs in myeloma are selected by their functional consequences. The novel dosage effect score defined in this work will facilitate integration of copy number and expression data for identifying driver

  4. Ionizing radiation

    Science.gov (United States)

    Tobias, C. A.; Grigoryev, Y. G.

    1975-01-01

    The biological effects of ionizing radiation encountered in space are considered. Biological experiments conducted in space and some experiences of astronauts during space flight are described. The effects of various levels of radiation exposure and the determination of permissible dosages are discussed.

  5. Low-dosage helical CT applications for chest medical checkup and lung cancer screening

    International Nuclear Information System (INIS)

    Wang Ping; Cui Fa; Liang Huanqing; Zheng Minfei

    2005-01-01

    Objective: A discussion on low-dosage helical CT applications on chest medical checkup and lung cancer screening. Methods: On the 100 chest medical check up with three different of protocols, including standard-dosage (the tube current was 230 mAs) were compared with low-dose (tube current was 50 mAs or 30 mAs). Results: Low-dosage helical CT scan provides excellent images. In 100 chest medical checkup, 39 nodules or masses were revealed, enlarged lymph node was noted in 1 case; emphysema or bullae was demonstrated in 3 segments; thickening of bronchial wall was shown in 2 cases; and localized pleural thickening was found in 1 case. Conclusion: In chest checkup or lung cancer screening low-dosage helical CT (tube current 30 mAs) will not only guarantee image quality but also reduce the radiation dose during the examination. (authors)

  6. Accurate Models for Evaluating the Direct Conducted and Radiated Emissions from Integrated Circuits

    Directory of Open Access Journals (Sweden)

    Domenico Capriglione

    2018-03-01

    Full Text Available This paper deals with the electromagnetic compatibility (EMC issues related to the direct and radiated emissions from a high-speed integrated circuits (ICs. These emissions are evaluated here by means of circuital and electromagnetic models. As for the conducted emission, an equivalent circuit model is derived to describe the IC and the effect of its loads (package, printed circuit board, decaps, etc., based on the Integrated Circuit Emission Model template (ICEM. As for the radiated emission, an electromagnetic model is proposed, based on the superposition of the fields generated in the far field region by the loop currents flowing into the IC and the package pins. A custom experimental setup is designed for validating the models. Specifically, for the radiated emission measurement, a custom test board is designed and realized, able to highlight the contribution of the direct emission from the IC, usually hidden by the indirect emission coming from the printed circuit board. Measurements of the package currents and of the far-field emitted fields are carried out, providing a satisfactory agreement with the model predictions.

  7. Pure radiation in space-time models that admit integration of the eikonal equation by the separation of variables method

    Science.gov (United States)

    Osetrin, Evgeny; Osetrin, Konstantin

    2017-11-01

    We consider space-time models with pure radiation, which admit integration of the eikonal equation by the method of separation of variables. For all types of these models, the equations of the energy-momentum conservation law are integrated. The resulting form of metric, energy density, and wave vectors of radiation as functions of metric for all types of spaces under consideration is presented. The solutions obtained can be used for any metric theories of gravitation.

  8. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  9. Clinical criteria for medical staff exposure and reference dosage within the Galician health Service; Criterios clinicos para exposiciones medicas y dosis de referencia en el Servicio Gallego de Salud

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Comesana, J.

    2003-07-01

    The generalised use of ionising radiation tests is making these tests become the prime cause of exposure to artificial radiation, receiving one sixth of the dosage through background radiation. (Author)

  10. Utilization of radiation protection gear for absorbed dose reduction: an integrative literature review

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Flor, Rita de Cassia; Pereira, Aline Garcia

    2011-01-01

    Objective: The present study was aimed at evaluating the relation between the use of radiation protection gear and the decrease in absorbed dose of ionizing radiation, thereby reinforcing the efficacy of its use by both the patients and occupationally exposed personnel. Materials and Methods: The integrative literature review method was utilized to analyze 21 articles, 2 books, 1 thesis, 1 monograph, 1 computer program, 4 pieces of database research (Instituto Brasileiro de Geografia e Estatistica and Departamento de Informatica do Sistema Unico de Saude) and 2 sets of radiological protection guidelines. Results: Theoretically, a reduction of 86% to 99% in the absorbed dose is observed with the use of radiation protection gear. In practice, however, the reduction may achieve 88% in patients submitted to conventional radiology, and 95% in patients submitted to computed tomography. In occupationally exposed individuals, the reduction is around 90% during cardiac catheterization, and 75% during orthopedic surgery. Conclusion: According to findings of several previous pieces of research, the use of radiation protection gear is a low-cost and effective way to reduce absorbed dose both for patients and occupationally exposed individuals. Thus, its use is necessary for the implementation of effective radioprotection programs in radiodiagnosis centers. (author)

  11. Low dose radiation effects: an integrative european approach (Risc-Rad Project) coordinated by the Cea

    International Nuclear Information System (INIS)

    Sabatier, L.

    2006-01-01

    RISC-RAD (Radiosensitivity of Individuals and Susceptibility to Cancer induced by ionizing Radiations) is an Integrated Project funded by the European Commission under 6. Framework Programme / EURATOM. RISC-RAD started on 1. January 2004 for a duration of four years. Coordinated by Cea (Dr Laure Sabatier), it involves 11 European countries (Austria, Denmark, Finland, France, Germany, Ireland, Italy, the Netherlands, Spain, Sweden and the United Kingdom) and 29 research institutions. Objectives: Exposures to low and protracted doses of ionizing radiation are very frequent in normal living environment, at work places, in industry and in medicine. Effects of these exposures on human health cannot be reliably assessed by epidemiological methods, nor is thoroughly understood by biologists. RISC-RAD project proposes to help bridging the gap of scientific knowledge about these effects. To achieve this goal, a necessary key step is to understand the basic mechanisms by which radiation induces cancer. Studying this multistage process in an integrated way, the project offers a new biological approach characterised by and clear-cut and objective-driven scientific policy: the project is focused on the effects of low doses (less than 100 mSv) and protracted doses of radiation. It aims at identifying new parameters that take into account the differences in radiation responses between individuals. A group of modelers works closely with the experimental teams in order to better quantify the risks associated with low and protracted doses. Research work is divided into five work packages interacting closely with each other. WP1 is dedicated to DNA damage. Ionizing Radiation (IR) produce a broad spectrum of base modifications and DNA strand breaks of different kinds, among which double-strand breaks and 'clustered damage' which is thought to be a major feature in biological effectiveness of IR. The aim of Work Package 1 is to improve understanding of the initial DNA damage induced by

  12. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  13. Methods and tools for the evaluation of the sensitivity to natural radiations of advanced integrated circuits

    International Nuclear Information System (INIS)

    Peronnard, P.

    2009-10-01

    Atmospheric neutrons, whose fluxes and energies dependent on the altitude, the sun activity and the geographic coordinates, have been identified as being capable to provoke SEE (Single Event Effects), by indirect ionisation, in integrated devices issued from advanced manufacturing processes (nano-metric devices). This concerns not only avionics but also applications operating at ground level. The evaluation of the sensitivity to SEE provoked by natural radiation becomes thus a mandatory step during the selection of devices devoted to be included in applications requiring high reliability. The sensitivity to SEE can be mitigated by different approaches at different levels from manufacturing level (use of particular process technologies such as SOI - Silicon On Isolator -) to the system level (hardware/software redundancy). Independently of the adopted hardening approach, the so-called radiation ground testing are mandatory to evaluate the error rates of a device or a system. During such tests, the DUT (Device Under Test) is exposed to a flux of particles while it performs a given activity. For SEU (Single Event Upsets) radiation ground testing, two main strategies exist: static test: the circuit areas which are supposed to be sensitive to SEUs (registers, memories,...) are initialized with a reference pattern. The content of the sensitive area is periodically compared to the reference pattern to identify potential SEU. Dynamic test: the DUT performs an activity representative of the one it will execute during the final application. Static test: strategies are frequently adopted as they provide the intrinsic sensitivity, in terms of the average number of particles needed to provoke an SEU, of different sensitive areas of the device. From such a strategy can thus be obtained a 'worst case estimation' of the device sensitivity. This thesis aims at giving a description and validating the methodologies required to estimate the sensitivity to radiations of two types of

  14. CONCERT. ''European joint programme for the integration of radiation protection research''

    International Nuclear Information System (INIS)

    Schmitt-Hannig, A.; Birschwilks, M.; Jung, T.

    2016-01-01

    CONCERT is a joint project of the EU and its member states which assume joint financing: Over the next five years the largest European radiation protection programme so far will have available about 28 Million Euros for research and integrative measures, whereby the European Commission will bear 70 per cent of the costs. Integrative measures include, among others, targeted vocational education and training of junior researchers in radiation protection, better access to research and irradiation facilities for scientists, as well as a stronger connection of universities and research centres in radiation protection research.

  15. INTEGRAL SPI Limits on Electron-Positron Annihilation Radiation from the Galactic Plane

    DEFF Research Database (Denmark)

    Teegarden, B. J.; Watanabe, K.; Jean, P.

    2005-01-01

    ‐Ray Astrophysics Laboratory) mission, launched in 2002 October, is the detailed study of this radiation. The Spectrometer on INTEGRAL (SPI) is a high‐resolution, coded‐aperture gamma‐ray telescope with an unprecedented combination of sensitivity, angular resolution, and energy resolution. We report results from...... the first 10 months of observation. During this period a significant fraction of the observing time was spent in or near the Galactic plane. No positive annihilation flux was detected outside of the central region () of our Galaxy. In this paper we describe the observations and data analysis methods...

  16. Integral method for the calculation of Hawking radiation in dispersive media. II. Asymmetric asymptotics.

    Science.gov (United States)

    Robertson, Scott

    2014-11-01

    Analog gravity experiments make feasible the realization of black hole space-times in a laboratory setting and the observational verification of Hawking radiation. Since such analog systems are typically dominated by dispersion, efficient techniques for calculating the predicted Hawking spectrum in the presence of strong dispersion are required. In the preceding paper, an integral method in Fourier space is proposed for stationary 1+1-dimensional backgrounds which are asymptotically symmetric. Here, this method is generalized to backgrounds which are different in the asymptotic regions to the left and right of the scattering region.

  17. Integral method for the calculation of Hawking radiation in dispersive media. I. Symmetric asymptotics

    Science.gov (United States)

    Robertson, Scott; Leonhardt, Ulf

    2014-11-01

    Hawking radiation has become experimentally testable thanks to the many analog systems which mimic the effects of the event horizon on wave propagation. These systems are typically dominated by dispersion and give rise to a numerically soluble and stable ordinary differential equation only if the rest-frame dispersion relation Ω2(k ) is a polynomial of relatively low degree. Here we present a new method for the calculation of wave scattering in a one-dimensional medium of arbitrary dispersion. It views the wave equation as an integral equation in Fourier space, which can be solved using standard and efficient numerical techniques.

  18. beta. -Amyloid gene dosage in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, G H; Manuelidis, L; Kim, J H; Manuelidis, E E

    1988-01-11

    The 4-5 kd amyloid ..beta..-peptide is a major constituent of the characteristic amyloid plaque of Alzheimer's disease. It has been reported that some cases of sporatic Alzheimer's disease are associated with at least a partial duplication of chromosome 21 containing the gene corresponding to the 695 residue precursor of this peptide. To contribute to an understanding of the frequency to such a duplication event in the overall Alzheimer's population, the authors have determined the gene dosage of the ..beta..-amyloid gene in this collection of cases. All cases had a clinical diagnosis of Alzheimer's confirmed neuropathologically. Each Alzheimer's case had an apparent normal diploid ..beta..-amyloid gene dosage, while control Down's cases had the expected triploid dosage. Thus partial duplication of chromosome 21 may be a rare finding in Alzheimer's disease. Similar conclusions were just reported in several studies of the Harvard Alzheimer collection.

  19. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  20. Radiation effects for high-energy protons and X-ray in integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, M.A.G.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Medina, N.H.; Added, N.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil); Cirne, K.H. [Empresa Brasileira de Aeronautica S.A. (EMBRAER), Sao Jose dos Campos, SP (Brazil)

    2012-07-01

    Full text: Electronic circuits are strongly influenced by ionizing radiation. The necessity to develop integrated circuits (IC's) featuring radiation hardness is largely growing to meet the stringent environment in space electronics [1]. This work aims to development a test platform to qualify electronic devices under the influence of high radiation dose, for aerospace applications. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them heavy ions, alpha particles, protons, gamma and X-rays. Radiation effects on the ICs are usually divided into three categories: Total Ionizing Dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; Single Events Effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits and Displacement Damage (DD) which can change the arrangement of the atoms in the lattice [2]. In this study we are investigating the radiation effects in rectangular-gate and circular-gate MOSFETs, manufactured with standard CMOS fabrication process, using particle beams produced in electrostatic tandem accelerators and X-rays. Initial tests for TID effects were performed using the 1.7 MV 5SDH tandem Pelletron accelerator of the Instituto de Fisica da USP with a proton beam of 2.6 MeV. The devices were exposed to different doses, varying the beam current, and irradiation time with the accumulated dose reaching up to Grad. To study the effect of X-rays on the electronic devices, an XRD-7000 (Shimadzu) X-ray setup was used as a primary X-ray source. The devices were irradiated with a total dose from krad to Grad using different dose rates. The results indicate that changes of the I-V characteristic curve are strongly dependents on the geometry of the devices. [1] Duzellier, S., Aerospace Science and Technology 9, p. 93

  1. Non-targeted effects of ionising radiation (note). A new European integrated project, 2006-2010

    International Nuclear Information System (INIS)

    Salomaa, S.; Wright, E.G.; Hildebrandt, G.; Kadhim, M.; Little, M.P.; Prise, K.M.; Belyakov, O.V.

    2007-01-01

    Complete text of publication follows. The general objectives of the NOTE project are: (1) to investigate the mechanisms of nontargeted effects, in particular, bystander effects, genomic instability and adaptive response; (2) to investigate if and how non-targeted effects modulate the cancer risk in the low dose region, and whether they relate to protective or harmful functions; (3) to investigate if ionising radiation can cause non-cancer diseases or beneficial effects at low and intermediate doses; (4) to investigate individual susceptibility and other factors modifying non-targeted responses; (5) to assess the relevance of non-targeted effects for radiation protection and to set the scientific basis for a modern, more realistic, radiation safety system; (6) to contribute to the conceptualisation of a new paradigm in radiation biology that would cover both the classical direct (DNA-targeted) and non-targeted (indirect) effects. The NOTE brings together 19 major European and Canadian groups involved in the discovery, characterisation and mechanistic investigation of non-targeted effects of ionising radiation in cellular, tissue and animal models. The NOTE research activities are organised in six work packages. Four work packages (WPs 2-5) are problem-oriented, focussing on major questions relevant for the scientific basis of the system of radiation protection: WP2 Mechanisms of non-targeted effects, WP3 Non-cancer diseases, WP4 Factors modifying non-targeted responses, WP5 Modelling of non-targeted effects. The integration activities provided by WP6 strengthen the collaboration by supporting the access to infrastructures, mobility and training. WP7 provides dissemination and exploitation activities in the form of workshops and a public website. Managerial activities (WP1) ensure the organisation and structures for decision making, monitoring of progress, knowledge management and efficient flow of information and financing. Coordinator of the NOTE project is Prof

  2. Radiation-Hard Complementary Integrated Circuits Based on Semiconducting Single-Walled Carbon Nanotubes.

    Science.gov (United States)

    McMorrow, Julian J; Cress, Cory D; Gaviria Rojas, William A; Geier, Michael L; Marks, Tobin J; Hersam, Mark C

    2017-03-28

    Increasingly complex demonstrations of integrated circuit elements based on semiconducting single-walled carbon nanotubes (SWCNTs) mark the maturation of this technology for use in next-generation electronics. In particular, organic materials have recently been leveraged as dopant and encapsulation layers to enable stable SWCNT-based rail-to-rail, low-power complementary metal-oxide-semiconductor (CMOS) logic circuits. To explore the limits of this technology in extreme environments, here we study total ionizing dose (TID) effects in enhancement-mode SWCNT-CMOS inverters that employ organic doping and encapsulation layers. Details of the evolution of the device transport properties are revealed by in situ and in operando measurements, identifying n-type transistors as the more TID-sensitive component of the CMOS system with over an order of magnitude larger degradation of the static power dissipation. To further improve device stability, radiation-hardening approaches are explored, resulting in the observation that SWNCT-CMOS circuits are TID-hard under dynamic bias operation. Overall, this work reveals conditions under which SWCNTs can be employed for radiation-hard integrated circuits, thus presenting significant potential for next-generation satellite and space applications.

  3. Integrating existing radiation monitors into a microprocessor-based display system

    International Nuclear Information System (INIS)

    Kalita, R, S.; Bartucci, C.M.; Mason, R.G.; Greaves, C.

    1992-01-01

    Plantwide digital radiation monitoring systems (RMSs) have been generally installed as part of the original design for newer nuclear reactors. For older plants, area and process radiation monitors were either analog or a combination of analog and digital but were not part of an integrated system design. At some plants, individual monitors have been replaced or modified, resulting in a rainbow of different monitors and vendors being represented at the plant. Usually at some point, consideration is given to replacing these monitors with a state-of-the-art RMS to improve overall reliability and achieve the benefits of sound human factors engineering. This can be a very costly project in terms of expenditures for engineering, equipment, construction, startup, and time. When human engineering deficiencies (HEDs) became an issue at Zion station, Commonwealth Edison elected to install a computer-based radiation monitoring display system (RMDS) that would interface existing raidation monitors. After reviewing the existing as-built RMS configuration and internal circuits of the various monitors, it was concluded that a microprocessor-based RMDS could be successfully designed and installed that would solve the HEDs and would tie the older analog channels into a system configuration. Although in many cases, internal modifications were made to existing RMS monitors, the RMDS upgrade allowed the existing RMS monitors to retain their original functionality and location

  4. Evaluation of HFIR [High Flux Isotope Reactor] pressure-vessel integrity considering radiation embrittlement

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Merkle, J.G.; Nanstad, R.K.

    1988-04-01

    The High Flux Isotope Reactor (HFIR) pressure vessel has been in service for 20 years, and during this time, radiation damage was monitored with a vessel-material surveillance program. In mid-November 1986, data from this program indicated that the radiation-induced reduction in fracture toughness was greater than expected. As a result, a reevaluation of vessel integrity was undertaken. Updated methods of fracture-mechanics analysis were applied, and an accelerated irradiations program was conducted using the Oak Ridge Research Reactor. Results of these efforts indicate that (1) the vessel life can be extended 10 years if the reactor power level is reduced 15% and if the vessel is subjected to a hydrostatic proof test each year; (2) during the 10-year life extension, significant radiation damage will be limited to a rather small area around the beam tubes; and (3) the greater-than-expected damage rate is the result of the very low neutron flux in the HFIR vessel relative to that in samples of material irradiated in materials-testing reactors (a factor of ∼10 4 less), that is, a rate effect

  5. [The reduction of the radiation dosage by means of storage phosphor-film radiography compared to a conventional film-screen system with a grid cassette on a skull phantom].

    Science.gov (United States)

    Heyne, J P; Merbold, H; Sehner, J; Neumann, R; Freesmeyer, M; Jonetz-Mentzel, L; Kaiser, W A

    1999-07-01

    How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? A skull phantom (3M) was x-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhöfer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. The surface entrance dose at 73 kV/22 mAs was 0.432 mGy in conventional screen film system and 0.435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0.308 mGy; SD 0.050); sufficient images were obtained down to an average dose of 31% (0.136 mGy; SD 0.065). The resolution of the line pairs were reduced down to 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resulted in an improvement of the assessment of bone structures and contrast in higher dose ranges only. For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement of the skull the dose can be reduced to at least 56% (phi 31%; SD 14.9%)/40% (phi 27%; SD 9.3%)/18% (phi 14%; SD 4.4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12.5 mAs and to skull measurement 73 kV/4 mAs.

  6. Intelligent system for improving dosage control

    Directory of Open Access Journals (Sweden)

    Fabio Cosme Rodrigues dos Santos

    2017-02-01

    Full Text Available Coagulation is one of the most important processes in a drinking-water treatment plant, and it is applied to destabilize impurities in water for the subsequent flocculation stage. Several techniques are currently used in the water industry to determine the best dosage of the coagulant, such as the jar-test method, zeta potential measurements, artificial intelligence methods, comprising neural networks, fuzzy and expert systems, and the combination of the above-mentioned techniques to help operators and engineers in the water treatment process. Current paper presents an artificial neural network approach to evaluate optimum coagulant dosage for various scenarios in raw water quality, using parameters such as raw water color, raw water turbidity, clarified and filtered water turbidity and a calculated Dose Rate to provide the best performance in the filtration process. Another feature in current approach is the use of a backpropagation neural network method to estimate the best coagulant dosage simultaneously at two points of the water treatment plant. Simulation results were compared to the current dosage rate and showed that the proposed system may reduce costs of raw material in water treatment plant.

  7. Spectrophotometric Determination of Trimipramine in Tablet Dosage ...

    African Journals Online (AJOL)

    Purpose: To develop and validate simple, rapid and sensitive spectrophotometric procedures for determination of trimipramine in tablet dosage form. Methods: The methods were based on the interaction of trimipramine as n-electron donor with the ο-acceptor, iodine and various π-acceptors, namely: chloranil (CH), ...

  8. A brief history of dosage compensation

    Indian Academy of Sciences (India)

    depression of X-linked gene activity in the female, as well as by hyperexpression of the ... to the Harvey lecture, Muller had presented important ideas relative to dosage ... at Columbia. I do recall a talk by the popular physical anthro- pologist ...

  9. A technique for estimating the probability of radiation-stimulated failures of integrated microcircuits in low-intensity radiation fields: Application to the Spektr-R spacecraft

    Science.gov (United States)

    Popov, V. D.; Khamidullina, N. M.

    2006-10-01

    In developing radio-electronic devices (RED) of spacecraft operating in the fields of ionizing radiation in space, one of the most important problems is the correct estimation of their radiation tolerance. The “weakest link” in the element base of onboard microelectronic devices under radiation effect is the integrated microcircuits (IMC), especially of large scale (LSI) and very large scale (VLSI) degree of integration. The main characteristic of IMC, which is taken into account when making decisions on using some particular type of IMC in the onboard RED, is the probability of non-failure operation (NFO) at the end of the spacecraft’s lifetime. It should be noted that, until now, the NFO has been calculated only from the reliability characteristics, disregarding the radiation effect. This paper presents the so-called “reliability” approach to determination of radiation tolerance of IMC, which allows one to estimate the probability of non-failure operation of various types of IMC with due account of radiation-stimulated dose failures. The described technique is applied to RED onboard the Spektr-R spacecraft to be launched in 2007.

  10. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  11. Contribution to the study of ionizing radiation effects on bipolar technologies: application to the hardening of integrated circuits

    International Nuclear Information System (INIS)

    Briand, R.

    2001-01-01

    The use of analog integrated circuits in radiation environments raises the problem of their behaviour with respect to the different effects induced by particles and radiations. The first chapter of this thesis presents the origins of radiations and the different topologies of bipolar transistors. The effects of ionizing radiations on bipolar components, like cumulative dose, dose rates, and single events, are detailed in three distinct chapters with the same scientifical approach. The simulation of the physical degradation phenomena of the components allows to establish original electrical models coming from the understanding of the induced mechanisms. These models are used to evaluate the degradations occurring in linear analogic circuits. Common and original hardening methods are presented, some of which are applied to bipolar integrated circuit technologies. Finally, experimental laser beam test techniques are presented, which are used to reproduce the dose rate and the single events. (J.S.)

  12. Alpha radiation detection using silicon memory chips - preliminary studies

    International Nuclear Information System (INIS)

    Pace, R.; Paix, D.; Haskard, M.

    1993-01-01

    Alpha radiation dosage is an important occupational health factor in the mining of uranium and mineral sands. Alpha radiation induced errors in the data of silicon based memory chips provide the foundation for a new type of sensor, with the potential for affordable and prompt measurement of personal alpha doses. With particular reference to Dynamic Random Access Memories (DRAM) this paper introduces the operating principle of a memory based radiation sensor, which is the error mechanism in silicon integrated circuits. 14 refs., 3 figs

  13. Integrated Radiation Transport and Nuclear Fuel Performance for Assembly-Level Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Clarno, Kevin T [ORNL; Hamilton, Steven P [ORNL; Philip, Bobby [ORNL; Berrill, Mark A [ORNL; Sampath, Rahul S [ORNL; Allu, Srikanth [ORNL; Pugmire, Dave [ORNL; Dilts, Gary [Los Alamos National Laboratory (LANL); Banfield, James E [ORNL

    2012-02-01

    The Advanced Multi-Physics (AMP) Nuclear Fuel Performance code (AMPFuel) is focused on predicting the temperature and strain within a nuclear fuel assembly to evaluate the performance and safety of existing and advanced nuclear fuel bundles within existing and advanced nuclear reactors. AMPFuel was extended to include an integrated nuclear fuel assembly capability for (one-way) coupled radiation transport and nuclear fuel assembly thermo-mechanics. This capability is the initial step toward incorporating an improved predictive nuclear fuel assembly modeling capability to accurately account for source-terms and boundary conditions of traditional (single-pin) nuclear fuel performance simulation, such as the neutron flux distribution, coolant conditions, and assembly mechanical stresses. A novel scheme is introduced for transferring the power distribution from the Scale/Denovo (Denovo) radiation transport code (structured, Cartesian mesh with smeared materials within each cell) to AMPFuel (unstructured, hexagonal mesh with a single material within each cell), allowing the use of a relatively coarse spatial mesh (10 million elements) for the radiation transport and a fine spatial mesh (3.3 billion elements) for thermo-mechanics with very little loss of accuracy. In addition, a new nuclear fuel-specific preconditioner was developed to account for the high aspect ratio of each fuel pin (12 feet axially, but 1 4 inches in diameter) with many individual fuel regions (pellets). With this novel capability, AMPFuel was used to model an entire 17 17 pressurized water reactor fuel assembly with many of the features resolved in three dimensions (for thermo-mechanics and/or neutronics), including the fuel, gap, and cladding of each of the 264 fuel pins; the 25 guide tubes; the top and bottom structural regions; and the upper and lower (neutron) reflector regions. The final, full assembly calculation was executed on Jaguar using 40,000 cores in under 10 hours to model over 162

  14. Association between sperm DNA integrity and seminal plasma antioxidant levels in health workers occupationally exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Kumar, Dayanidhi; Salian, Sujith Raj; Kalthur, Guruprasad; Uppangala, Shubhashree; Kumari, Sandhya; Challapalli, Srinivas; Chandraguthi, Shrinidhi Gururajarao; Jain, Navya; Krishnamurthy, Hanumanthappa; Kumar, Pratap; Adiga, Satish Kumar

    2014-01-01

    There is a paucity of data regarding the association between occupational radiation exposure and risk to human fertility. Recently, we provided the first evidence on altered sperm functional characteristics, DNA damage and hypermethylation in radiation health workers. However, there is no report elucidating the association between seminal plasma antioxidants and sperm chromatin integrity in occupationally exposed subjects. Here, we assessed the seminal plasma antioxidants and lipid peroxidation level in 83 men who were occupationally exposed to ionizing radiation and then correlated with the sperm chromatin integrity. Flow cytometry based sperm chromatin integrity assay revealed a significant decline in αt value in the exposed group in comparison to the non-exposed group (P<0.0001). Similarly, both total and reduced glutathione levels and total antioxidant capacity in the seminal plasma were significantly higher in exposed group than the non-exposed group (P<0.01, 0.001 and 0.0001, respectively). However, superoxide dismutase level and malondialdehyde level, which is an indicator of lipid peroxidation in the seminal plasma, did not differ significantly between two groups. The total antioxidant capacity (TAC) and GSH level exhibited a positive correlation with sperm DNA integrity in exposed subjects. To conclude, this study distinctly shows that altered sperm chromatin integrity in radiation health workers is associated with increase in seminal plasma antioxidant level. Further, the increased seminal plasma GSH and TAC could be an adaptive measure to tackle the oxidative stress to protect genetic and functional sperm deformities in radiation health workers. - Highlights: • Seminal plasma antioxidants were measured in men occupationally exposed to radiation. • Sperm chromatin integrity was significantly affected in the exposed group. • Glutathione and total antioxidant capacity was significantly higher in exposed group. • Sperm DNA damage in exposed subjects

  15. Association between sperm DNA integrity and seminal plasma antioxidant levels in health workers occupationally exposed to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Dayanidhi; Salian, Sujith Raj; Kalthur, Guruprasad; Uppangala, Shubhashree; Kumari, Sandhya [Division of Clinical Embryology, Department of Obstetrics and Gynecology, Kasturba Medical College, Manipal University, Manipal 576104 (India); Challapalli, Srinivas [Department of Radiotherapy, Kasturba Medical College, Mangalore (India); Chandraguthi, Shrinidhi Gururajarao [Department of Radiotherapy and Oncology, Kasturba Medical College, Manipal (India); Jain, Navya; Krishnamurthy, Hanumanthappa [National Centre for Biological Sciences, Bangalore (India); Kumar, Pratap [Department of Obstetrics and Gynecology, Kasturba Medical College, Manipal University, Manipal (India); Adiga, Satish Kumar, E-mail: satish.adiga@manipal.edu [Division of Clinical Embryology, Department of Obstetrics and Gynecology, Kasturba Medical College, Manipal University, Manipal 576104 (India)

    2014-07-15

    There is a paucity of data regarding the association between occupational radiation exposure and risk to human fertility. Recently, we provided the first evidence on altered sperm functional characteristics, DNA damage and hypermethylation in radiation health workers. However, there is no report elucidating the association between seminal plasma antioxidants and sperm chromatin integrity in occupationally exposed subjects. Here, we assessed the seminal plasma antioxidants and lipid peroxidation level in 83 men who were occupationally exposed to ionizing radiation and then correlated with the sperm chromatin integrity. Flow cytometry based sperm chromatin integrity assay revealed a significant decline in αt value in the exposed group in comparison to the non-exposed group (P<0.0001). Similarly, both total and reduced glutathione levels and total antioxidant capacity in the seminal plasma were significantly higher in exposed group than the non-exposed group (P<0.01, 0.001 and 0.0001, respectively). However, superoxide dismutase level and malondialdehyde level, which is an indicator of lipid peroxidation in the seminal plasma, did not differ significantly between two groups. The total antioxidant capacity (TAC) and GSH level exhibited a positive correlation with sperm DNA integrity in exposed subjects. To conclude, this study distinctly shows that altered sperm chromatin integrity in radiation health workers is associated with increase in seminal plasma antioxidant level. Further, the increased seminal plasma GSH and TAC could be an adaptive measure to tackle the oxidative stress to protect genetic and functional sperm deformities in radiation health workers. - Highlights: • Seminal plasma antioxidants were measured in men occupationally exposed to radiation. • Sperm chromatin integrity was significantly affected in the exposed group. • Glutathione and total antioxidant capacity was significantly higher in exposed group. • Sperm DNA damage in exposed subjects

  16. Accelerating execution of the integrated TIGER series Monte Carlo radiation transport codes

    International Nuclear Information System (INIS)

    Smith, L.M.; Hochstedler, R.D.

    1997-01-01

    Execution of the integrated TIGER series (ITS) of coupled electron/photon Monte Carlo radiation transport codes has been accelerated by modifying the FORTRAN source code for more efficient computation. Each member code of ITS was benchmarked and profiled with a specific test case that directed the acceleration effort toward the most computationally intensive subroutines. Techniques for accelerating these subroutines included replacing linear search algorithms with binary versions, replacing the pseudo-random number generator, reducing program memory allocation, and proofing the input files for geometrical redundancies. All techniques produced identical or statistically similar results to the original code. Final benchmark timing of the accelerated code resulted in speed-up factors of 2.00 for TIGER (the one-dimensional slab geometry code), 1.74 for CYLTRAN (the two-dimensional cylindrical geometry code), and 1.90 for ACCEPT (the arbitrary three-dimensional geometry code)

  17. Accelerating execution of the integrated TIGER series Monte Carlo radiation transport codes

    Science.gov (United States)

    Smith, L. M.; Hochstedler, R. D.

    1997-02-01

    Execution of the integrated TIGER series (ITS) of coupled electron/photon Monte Carlo radiation transport codes has been accelerated by modifying the FORTRAN source code for more efficient computation. Each member code of ITS was benchmarked and profiled with a specific test case that directed the acceleration effort toward the most computationally intensive subroutines. Techniques for accelerating these subroutines included replacing linear search algorithms with binary versions, replacing the pseudo-random number generator, reducing program memory allocation, and proofing the input files for geometrical redundancies. All techniques produced identical or statistically similar results to the original code. Final benchmark timing of the accelerated code resulted in speed-up factors of 2.00 for TIGER (the one-dimensional slab geometry code), 1.74 for CYLTRAN (the two-dimensional cylindrical geometry code), and 1.90 for ACCEPT (the arbitrary three-dimensional geometry code).

  18. Investigation of singularities of integral intensity of the relativistic particle bremsstrahlung radiation in a diamond crystal

    International Nuclear Information System (INIS)

    Avakyan, R.O.; Armaganyan, A.A.; Arutyunyan, L.G.; Iskandaryan, A.G.; Taroyan, S.P.

    1981-01-01

    The results are given of the theoretical processing of experimental data on the investigation of orientational dependences of integral intensity of coherent bremsstrahlung radiation (CBR) of superfast electrons in a diamond crystal. It is shown that in the case of ''point effect'' right up to the electrons incident angle, which is 0.1 mrad with respect to the crystallographic plane, the CBR theory gives a good description of experimental data. In the case of ''row effect'', in order to account for the divergence between the theory and experiment at small incident angles of electrons with respect to the crystallographic axis, it is assumed that the multiple scattering angle has an orientational dependence. By fitting the theoretical curve to experimental points the dependences are obtained of the multiple scattering angle change on the crystal orientation with respect to the electron beam

  19. Laser-induced extreme UV radiation sources for manufacturing next-generation integrated circuits

    International Nuclear Information System (INIS)

    Borisov, V M; Vinokhodov, A Yu; Ivanov, A S; Kiryukhin, Yu B; Mishchenko, V A; Prokof'ev, A V; Khristoforov, O B

    2009-01-01

    The development of high-power discharge sources emitting in the 13.5±0.135-nm spectral band is of current interest because they are promising for applications in industrial EUV (extreme ultraviolet) lithography for manufacturing integrated circuits according to technological precision standards of 22 nm and smaller. The parameters of EUV sources based on a laser-induced discharge in tin vapours between rotating disc electrodes are investigated. The properties of the discharge initiation by laser radiation at different wavelengths are established and the laser pulse parameters providing the maximum energy characteristics of the EUV source are determined. The EUV source developed in the study emits an average power of 276 W in the 13.5±0.135-nm spectral band on conversion to the solid angle 2π sr in the stationary regime at a pulse repetition rate of 3000 Hz. (laser applications and other topics in quantum electronics)

  20. Integrated High-Rate Transition Radiation Detector and Tracking Chamber for the LHC

    CERN Multimedia

    2002-01-01

    % RD-6 \\\\ \\\\Over the past five years, RD-6 has developed a transition radiation detector and charged particle tracker for high rate operation at LHC. The detector elements are based on C-fibre reinforced kapton straw tubes of 4~mm diameter filled with a Xenon gas mixture. Detailed measurements with and without magnetic field have been performed in test beams, and in particular have demonstrated the possibility of operating straw tubes at very high rate (up to 20~MHz) with accurate drift-time measurement accuracy. A full-scale engineering prototype containing 10~000 straws is presently under assembly and will be accurately measured with a powerful X-ray tube. Integrated front-end electronics with fast readout have been designed and successfully operated in test beam. \\\\ \\\\Finally extensive simulations performed for ATLAS have shown that such a detector will provide powerful pattern recognition, accurate momentum measurements, efficient level-2 triggering and excellent electron identification, even at the highe...

  1. Design and characterization of radiation resistant integrated circuits for the LHC particle detectors using deep sub-micron CMOS technologies

    International Nuclear Information System (INIS)

    Anelli, Giovanni Maria

    2000-01-01

    The electronic circuits associated with the particle detectors of the CERN Large Hadron Collider (LHC) have to work in a highly radioactive environment. This work proposes a methodology allowing the design of radiation resistant integrated circuits using the commercial sub-micron CMOS technology. This method uses the intrinsic radiation resistance of ultra-thin grid oxides, the technology of enclosed layout transistors (ELT), and the protection rings to avoid the radio-induced creation of leakage currents. In order to check the radiation tolerance level, several test structures have been designed and tested with different radiation sources. These tests have permitted to study the physical phenomena responsible for the damages induced by the radiations and the possible remedies. Then, the particular characteristics of ELT transistors and their influence on the design of complex integrated circuits has been explored. The modeling of the W/L ratio, the asymmetries (for instance in the output conductance) and the performance of ELT couplings have never been studied yet. The noise performance of the 0.25 μ CMOS technology, used in the design of several integrated circuits of the LHC detectors, has been characterized before and after irradiation. Finally, two integrated circuits designed using the proposed method are presented. The first one is an analogic memory and the other is a circuit used for the reading of the signals of one of the LHC detectors. Both circuits were irradiated and have endured very high doses practically without any sign of performance degradation. (J.S.)

  2. Optimizing the dosage of stabilizing chemical

    OpenAIRE

    Harjula, Tomi

    2013-01-01

    A chemical company provides chemical treatment at customer mill in paper industry. This thesis work was done to determine the optimum dosage of stabilizing chemical. The theoretical framework explains the basics of paper brightness and bleaching and how these topics are connected to each other. The knowledge gained is very valuable and can possibly be used in the future in other similar applications as well. This thesis work contains confidential back ground information. Key ...

  3. Direct effects of ionizing radiation on integral membrane proteins. Noncovalent energy transfer requires specific interpeptide interactions

    International Nuclear Information System (INIS)

    Jhun, E.; Jhun, B.H.; Jones, L.R.; Jung, C.Y.

    1991-01-01

    The 12 transmembrane alpha helices (TMHs) of human erythrocyte glucose transporter were individually cut by pepsin digestion as membrane-bound 2.5-3.5-kDa peptide fragments. Radiation-induced chemical degradation of these fragments showed an average target size of 34 kDa. This is 10-12 x larger than the average size of an individual TMH, demonstrating that a significant energy transfer occurs among these TMHs in the absence of covalent linkage. Heating this TMH preparation at 100 degree C for 15 min reduced the target size to 5 kDa or less, suggesting that the noncovalent energy transfer requires specific helix-helix interactions. Purified phospholamban, a small (6-kDa) integral membrane protein containing a single TMH, formed a pentameric assembly in sodium dodecyl sulfate. The chemical degradation target size of this phospholamban pentamer was 5-6 kDa, illustrating that not all integral membrane protein assemblies permit intersubunit energy transfer. These findings together with other published observations suggest strongly that significant noncovalent energy transfer can occur within the tertiary and quaternary structure of membrane proteins and that as yet undefined proper molecular interactions are required for such covalent energy transfer. Our results with pepsin-digested glucose transporter also illustrate the importance of the interhelical interaction as a predominating force in maintaining the tertiary structure of a transmembrane protein

  4. Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit

    Institute of Scientific and Technical Information of China (English)

    Ding Lili; Guo Hongxia; Chen Wei; Fan Ruyu

    2012-01-01

    Radiation-induced inter-device leakage is studied using an analytical model and TCAD simulation.There were some different opinions in understanding the process of defect build-up in trench oxide and parasitic leakage path turning on from earlier studies.To reanalyze this problem and make it beyond argument,every possible variable is considered using theoretical analysis,not just the change of electric field or oxide thickness independently.Among all possible inter-device leakage paths,parasitic structures with N-well as both drain and source are comparatively more sensitive to the total dose effect when a voltage discrepancy exists between the drain and source region.Since N-well regions are commonly connected to the same power supply,these kinds of structures will not be a problem in a real CMOS integrated circuit.Generally speaking,conduction paths of inter-device leakage existing in a real integrated circuit and under real electrical circumstances are not very sensitive to the total ionizing dose effect.

  5. Integrative shell of the program complex MARS (Version 1.0) radiation transfer in three-dimensional geometries

    International Nuclear Information System (INIS)

    Degtyarev, I.I.; Lokhovitskij, A.E.; Maslov, M.A.; Yazynin, I.A.

    1994-01-01

    The first version of integrative shell of the program complex MARS is written for calculating radiation transfer in the three-dimensional geometries. The integrative shell allows the user to work in convenient form with complex MARS, creat input files data and get graphic visualization of calculated functions. Version 1.0 is adapted for personal computers of types IBM-286,386,486 with operative size memory not smaller than 500K. 5 refs

  6. Fully implicit solution of large-scale non-equilibrium radiation diffusion with high order time integration

    International Nuclear Information System (INIS)

    Brown, Peter N.; Shumaker, Dana E.; Woodward, Carol S.

    2005-01-01

    We present a solution method for fully implicit radiation diffusion problems discretized on meshes having millions of spatial zones. This solution method makes use of high order in time integration techniques, inexact Newton-Krylov nonlinear solvers, and multigrid preconditioners. We explore the advantages and disadvantages of high order time integration methods for the fully implicit formulation on both two- and three-dimensional problems with tabulated opacities and highly nonlinear fusion source terms

  7. Microbial quality of some herbal solid dosage forms

    African Journals Online (AJOL)

    STORAGESEVER

    2010-03-15

    Mar 15, 2010 ... Key words: Microbial quality, herbal, contamination, solid dosage form ... The type of dosage form, packaging, manufacturing and expiration dates of subject solid herbal .... According to WHO report (2002), Salmonella food.

  8. The effect of decreasing computed tomography dosage on radiostereometric analysis (RSA) accuracy at the glenohumeral joint.

    Science.gov (United States)

    Fox, Anne-Marie V; Kedgley, Angela E; Lalone, Emily A; Johnson, James A; Athwal, George S; Jenkyn, Thomas R

    2011-11-10

    Standard, beaded radiostereometric analysis (RSA) and markerless RSA often use computed tomography (CT) scans to create three-dimensional (3D) bone models. However, ethical concerns exist due to risks associated with CT radiation exposure. Therefore, the aim of this study was to investigate the effect of decreasing CT dosage on RSA accuracy. Four cadaveric shoulder specimens were scanned using a normal-dose CT protocol and two low-dose protocols, where the dosage was decreased by 89% and 98%. 3D computer models of the humerus and scapula were created using each CT protocol. Bi-planar fluoroscopy was used to image five different static glenohumeral positions and two dynamic glenohumeral movements, of which a total of five static and four dynamic poses were selected for analysis. For standard RSA, negligible differences were found in bead (0.21±0.31mm) and bony landmark (2.31±1.90mm) locations when the CT dosage was decreased by 98% (p-values>0.167). For markerless RSA kinematic results, excellent agreement was found between the normal-dose and lowest-dose protocol, with all Spearman rank correlation coefficients greater than 0.95. Average root mean squared errors of 1.04±0.68mm and 2.42±0.81° were also found at this reduced dosage for static positions. In summary, CT dosage can be markedly reduced when performing shoulder RSA to minimize the risks of radiation exposure. Standard RSA accuracy was negligibly affected by the 98% CT dose reduction and for markerless RSA, the benefits of decreasing CT dosage to the subject outweigh the introduced errors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yidong, E-mail: yidongyang@med.miami.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 and Department of Radiation Oncology, University of Miami School of Medicine, Miami, Florida 33136 (United States); Wang, Ken Kang-Hsin; Wong, John W. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Eslami, Sohrab; Iordachita, Iulian I. [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Patterson, Michael S. [Juravinski Cancer Centre and Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S4K1 (Canada)

    2015-04-15

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3

  10. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    International Nuclear Information System (INIS)

    Yang, Yidong; Wang, Ken Kang-Hsin; Wong, John W.; Eslami, Sohrab; Iordachita, Iulian I.; Patterson, Michael S.

    2015-01-01

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3

  11. Integrated control of Rapeseed pests

    International Nuclear Information System (INIS)

    Khattak, S.U.; Hamed, M.

    1990-06-01

    Rapeseed crop is attacked by different insects amongst which cabbage butterfly in Pakistan. Integrated control was conducted and results are mentioned in this report. The mortality in the remaining insecticides varied from 55-83% which was significantly higher than control. The higher dosages of gamma radiation ranged between 60-225 krad and results revealed that the mortality response increased with the post-irradiation time. Mortality was also significantly higher at 80-120 krad as compared to control. These results concluded that mortality was dose dependent. (A.B.)

  12. Development of a compact light weight DELRAD probe and its integration with UAV NETRA for aerial radiation surveillance

    International Nuclear Information System (INIS)

    Prasad, Mahaveer; Yadav, Ashok Kumar; Gupta, D.K.; Bhatnagar, Vivek; Singh, Chiman; Mishrilal

    2018-01-01

    The DEfence Laboratory RAdiation Detector - 'DELRAD' is an indigenously developed Hybrid Micro Circuit Module employing Si PIN diodes for detection of gamma radiation. Using this as a detector, the 'DELRAD Probe' has been designed and developed specifically for the UAV, NETRA for aerial surveillance of the nuclear affected areas. The critical requirement of very light weight radiation sensor as payload (<50gm) for the UAV NETRA is met by designing this Probe weighing approx. 40gm. The sensor is capable of measuring gamma radiation levels from 1mR/h to 1000R/h. The Probe has been tested, calibrated and integrated with the UAV NETRA. In addition to this, the radiation testing during flight of UAV NETRA integrated with DELRAD probe has also been carried out and results have been recorded. The work carried out proves the capability of Defence Laboratory, Jodhpur, (DRDO) in the area of 'Aerial Surveillance of Nuclear Radiation Affected Area' using Unmanned Aerial Vehicles (UAVs)

  13. Three-Year Outcomes of Breast Intensity-Modulated Radiation Therapy With Simultaneous Integrated Boost

    International Nuclear Information System (INIS)

    McDonald, Mark W.; Godette, Karen D.; Whitaker, Daisy J.; Davis, Lawrence W.; Johnstone, Peter A.S.

    2010-01-01

    Purpose: To report our clinical experience using breast intensity-modulated radiation therapy with simultaneous integrated boost (SIB-IMRT). Methods and Materials: Retrospective review identified 354 Stage 0 to III breast cancer patients treated with SIB-IMRT after conservative surgery between 2003 and 2006. The most common fractionation (89%) simultaneously delivered 1.8 Gy to the ipsilateral breast tissue and 2.14 Gy to the resection cavity, yielding a breast dose of 45 Gy (25 fractions) and cavity dose 59.92 Gy (28 fractions), biologically equivalent for tumor control to 45 Gy to the breast with sequential 16-Gy boost (33 fractions). Results: A total of 356 breasts in 354 patients were treated: 282 with invasive breast cancer, and 74 with ductal carcinoma in situ (DCIS). For left breast radiation, median cardiac V 15 was 2.9% and left ventricular V 15 1.7%. Median follow-up was 33 months (range, 4-73 months). Acute toxicity was Grade 1 in 57% of cases, Grade 2 in 43%, and Grade 3 in <1%. For invasive breast cancer, the 3-year overall survival was 97.6% and risk of any locoregional recurrence was 2.8%. For ductal carcinoma in situ, 3-year overall survival was 98% and risk of locoregional recurrence 1.4%. In 142 cases at a minimum of 3 years follow-up, global breast cosmesis was judged by physicians as good or excellent in 96.5% and fair in 3.5%. Conclusions: Breast SIB-IMRT reduced treatment duration by five fractions with a favorable acute toxicity profile and low cardiac dose for left breast treatment. At 3 years, locoregional control was excellent, and initial assessment suggested good or excellent cosmesis in a high percentage of evaluable patients.

  14. Radiation-hardened gate-around n-MOSFET structure for radiation-tolerant application-specific integrated circuits

    International Nuclear Information System (INIS)

    Lee, Min Su; Lee, Hee Chul

    2012-01-01

    To overcome the total ionizing dose effect on an n-type metal-oxide-semiconductor field-effect transistor (n-MOSFET), we designed a radiation-hardened gate-around n-MOSFET structure and evaluated it through a radiation-exposure experiment. Each test device was fabricated in a commercial 0.35-micron complementary metal-oxide-semiconductor (CMOS) process. The fabricated devices were evaluated under a total dose of 1 Mrad (Si) at a dose rate of 250 krad/h to obtain very high reliability for space electronics. The experimental results showed that the gate-around n-MOSFET structure had very good performance against 1 Mrad (Si) of gamma radiation, while the conventional n-MOSFET experienced a considerable amount of radiation-induced leakage current. Furthermore, a source follower designed with the gate-around transistor worked properly at 1 Mrad (Si) of gamma radiation while a source follower designed with the conventional n-MOSFET lost its functionality.

  15. Integrated Effect of Seeding Rate, Herbicide Dosage and ...

    African Journals Online (AJOL)

    yield reductions of 26 to 63% across four bread wheat cultivars at 90 weed seedlings m-2 in. Ethiopia. Before herbicides were widely available, farmers employed cultural measures to manage weed population. Wild oat management systems have evolved to the point that producers rely on herbicides to the virtual exclusion ...

  16. Dosimetric evaluation of simultaneous integrated boost during stereotactic body radiation therapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wensha, E-mail: wensha.yang@cshs.org [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Reznik, Robert; Fraass, Benedick A. [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Nissen, Nicholas [Department of Surgery, Cedars Sinai Medical Center, Los Angeles, CA (United States); Hendifar, Andrew [Department of Gastrointestinal Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Wachsman, Ashley [Department of Cross-Sectional Imaging Interventional Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States); Sandler, Howard; Tuli, Richard [Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA (United States)

    2015-04-01

    Stereotactic body radiation therapy (SBRT) provides a promising way to treat locally advanced pancreatic cancer and borderline resectable pancreatic cancer. A simultaneous integrated boost (SIB) to the region of vessel abutment or encasement during SBRT has the potential to downstage otherwise likely positive surgical margins. Despite the potential benefit of using SIB-SBRT, the ability to boost is limited by the local geometry of the organs at risk (OARs), such as stomach, duodenum, and bowel (SDB), relative to tumor. In this study, we have retrospectively replanned 20 patients with 25 Gy prescribed to the planning target volume (PTV) and 33~80 Gy to the boost target volume (BTV) using an SIB technique for all patients. The number of plans and patients able to satisfy a set of clinically established constraints is analyzed. The ability to boost vessels (within the gross target volume [GTV]) is shown to correlate with the overlap volume (OLV), defined to be the overlap between the GTV + a 1(OLV1)- or 2(OLV2)-cm margin with the union of SDB. Integral dose, boost dose contrast (BDC), biologically effective BDC, tumor control probability for BTV, and normal tissue complication probabilities are used to analyze the dosimetric results. More than 65% of the cases can deliver a boost to 40 Gy while satisfying all OAR constraints. An OLV2 of 100 cm{sup 3} is identified as the cutoff volume: for cases with OLV2 larger than 100 cm{sup 3}, it is very unlikely the case could achieve 25 Gy to the PTV while successfully meeting all the OAR constraints.

  17. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Multimedia

    Liberali, V; Rizzi, A; Re, V; Minuti, M; Pangaud, P; Barbero, M B; Pacher, L; Kluit, R; Hinchliffe, I; Manghisoni, M; Giubilato, P; Faccio, F; Pernegger, H; Krueger, H; Gensolen, F D; Bilei, G M; Da rocha rolo, M D; Prydderch, M L; Fanucci, L; Grillo, A A; Bellazzini, R; Palomo pinto, F R; Michelis, S; Huegging, F G; Kishishita, T; Marchiori, G; Christian, D C; Kaestli, H C; Meier, B; Andreazza, A; Key-charriere, M; Linssen, L; Dannheim, D; Conti, E; Hemperek, T; Menouni, M; Fougeron, D; Genat, J; Bomben, M; Marzocca, C; Demaria, N; Mazza, G; Van bakel, N A; Palla, F; Grippo, M T; Magazzu, G; Ratti, L; Abbaneo, D; Crescioli, F; Deptuch, G W; Neue, G; De robertis, G; Passeri, D; Placidi, P; Gromov, V; Morsani, F; Paccagnella, A; Christiansen, J; Dho, E; Wermes, N; Rymaszewski, P; Rozanov, A; Wang, A; Lipton, R J; Havranek, M; Neviani, A; Marconi, S; Karagounis, M; Godiot, S; Calderini, G; Seidel, S C; Horisberger, R P; Garcia-sciveres, M A; Stabile, A; Beccherle, R; Bacchetta, N

    The present hybrid pixel detectors in operation at the LHC represent a major achievement. They deployed a new technology on an unprecedented scale and their success firmly established pixel tracking as indispensable for future HEP experiments. However, extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. We propose a new RD collaboration specifically focused on the development of pixel readout Integrated Circuits (IC). The IC challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm$^{2}$), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. We propose a collaboration to design the next generation of hybrid pixel readout chips to enable the ATLAS and CMS Phase 2 pixel upgrades. This does not imply that ATLAS and CMS must use the same exact pixel readout chip, as most of the dev...

  18. Hydrogenated Amorphous Silicon Sensor Deposited on Integrated Circuit for Radiation Detection

    CERN Document Server

    Despeisse, M; Jarron, P; Kaplon, J; Moraes, D; Nardulli, A; Powolny, F; Wyrsch, N

    2008-01-01

    Radiation detectors based on the deposition of a 10 to 30 mum thick hydrogenated amorphous silicon (a-Si:H) sensor directly on top of integrated circuits have been developed. The performance of this detector technology has been assessed for the first time in the context of particle detectors. Three different circuits were designed in a quarter micron CMOS technology for these studies. The so-called TFA (Thin-Film on ASIC) detectors obtained after deposition of a-Si:H sensors on the developed circuits are presented. High internal electric fields (104 to 105 V/cm) can be built in the a-Si:H sensor and overcome the low mobility of electrons and holes in this amorphous material. However, the deposited sensor's leakage current at such fields turns out to be an important parameter which limits the performance of a TFA detector. Its detailed study is presented as well as the detector's pixel segmentation. Signal induction by generated free carrier motion in the a-Si:H sensor has been characterized using a 660 nm pul...

  19. A novel integrated circuit for semiconductor radiation detectors with sparse readout

    International Nuclear Information System (INIS)

    Zhang Yacong; Chen Zhognjian; Lu Wengao; Zhao Baoying; Ji Lijiu

    2008-01-01

    A novel fully integrated CMOS readout circuit for semiconductor radiation detector with sparse readout is presented. The new sparse scheme is: when one channel is being read out, the trigger signal from other channels is delayed and then processed. Therefore, the dead time is reduced and so is the error rate. Besides sparse readout, sequential readout is also allowed, which means the analog voltages and addresses of all the channels are read out sequentially once there is a channel triggered. The circuit comprises Charge Sensitive Amplifier (CSA), pulse shaper, peak detect and hold circuit, and digital logic. A test chip of four channels designed in a 0.5 μ DPTM CMOS technology has been taped out. The results of post simulation indicate that the gain is 79.3 mV/fC with a linearity of 99.92%. The power dissipation is 4 mW per channel. Theory analysis and calculation shows that the error probability is approximately 2.5%, which means a reduction of about 37% is obtained compared with the traditional scanning scheme, assuming a 16-channel system with a particle rate of 100 k/s per channel. (authors)

  20. Dosage of DTPA administration by inhalation

    International Nuclear Information System (INIS)

    Koizumi, Akira; Fukuda, Satoshi; Yamada, Yuji; Iida, Haruzo; Shimo, Michikuni

    2000-01-01

    The administration of DTPA by inhalation was examined as an emergency medical treatment. In order to estimate the practical dosage to the human, an accurate model of the human air way was connected to a anesthetizer and respiration was simulated. Ca-DTPA, aerosolized by an ultra-sonic nebulizer, was administered by inhalation to the model. For the experiments, the respiratory volume (tidal volume) and the respiration rate was 12 per minute. Irrigation water from the model of larynx and mouth, and the air filter were collected and measured by chelate titration in order to determine the quantity of aerosolized DTPA and the amount deposited on the trachea and lang. The results indicated that the quantity of aerosolized DTPA varied with dilution of the DTPA solution in a ample. It was found that a 3 time dilution was the most practical and that 73 mg of DTPA per minute could be aerosolized. Furthermore, the results indicated that 46% of the aerosolized DTPA was taken in through inhalation and that 26% of DTPA was deposited in the trachea and lung. These results suggest that in practical application in the emergency medical treatment, 15 minutes of inhalation could delivered to approximately 500 mg of DTPA, and 130 mg could be delivered to the trachea and lung. It is considered that these quantity are enough amount to increase the effects of radioactive nuclides from the body, comparing with the recommended dosage for injection administration. (author)

  1. The characteristics of novel dosage forms

    Directory of Open Access Journals (Sweden)

    Milić-Aškrabić Jela

    2003-01-01

    Full Text Available The objective of pharmaceutical-technological development is to find a procedure of transforming an active substance (a drug into a drug dosage form which is not only acceptable for application, but also enables the active substance to be released following administration, pursuant to therapy objectives. The aim is that the concentration of the active substance in the action location rapidly reaches a therapeutic level and maintains an approximately constant level in the course of a particular time, according to the established therapeutic goal. The primary objective is to present the active ingredient (drug in the form and concentration/quantity that enables the corresponding therapeutic response, i.e. to control the site and rate of medicinal substance release from the drug, as well as the rate at which it reaches the membranes and surfaces to which it is absorbed, while applying a common method of administration. The procedures used to achieve this goal are becoming highly complex and demanding and are aiming at sophisticated drug delivery systems and functional packaging material. Development from the existing drug molecule, through the conventional drug dosage form, to a new system of drug "delivery" (novel delivery system, can improve the drug (active substance characteristics significantly in view of compliance (acceptability by the patient, safety and efficiency. The paper presents an overview of the most important examples of pharmaceutical forms with controlled release and advanced drug "carriers".

  2. Radioactivity in food and the environment: calculations of UK radiation doses using integrated methods

    International Nuclear Information System (INIS)

    Allott, Rob

    2003-01-01

    Dear Sir: I read with interest the paper by W C Camplin, G P Brownless, G D Round, K Winpenny and G J Hunt from the Centre for Environment, Fisheries and Aquaculture Science (CEFAS) on 'Radioactivity in food and the environment: calculations of UK radiation doses using integrated methods' in the December 2002 issue of this journal (J. Radiol. Prot. 22 371-88). The Environment Agency has a keen interest in the development of a robust methodology for assessing total doses which have been received by members of the public from authorised discharges of radioactive substances to the environment. Total dose in this context means the dose received from all authorised discharges and all exposure pathways (e.g. inhalation, external irradiation from radionuclides in sediment/soil, direct radiation from operations on a nuclear site, consumption of food etc). I chair a 'total retrospective dose assessment' working group with representatives from the Scottish Environment Protection Agency (SEPA), Food Standards Agency (FSA), National Radiological Protection Board, CEFAS and BNFL which began discussing precisely this issue during 2002. This group is a sub-group of the National Dose Assessment Working Group which was set up in April 2002 (J. Radiol. Prot. 22 318-9). The Environment Agency, Food Standards Agency and the Nuclear Installations Inspectorate previously undertook joint research into the most appropriate methodology to use for total dose assessment (J J Hancox, S J Stansby and M C Thorne 2002 The Development of a Methodology to Assess Population Doses from Multiple Source and Exposure Pathways of Radioactivity (Environment Agency R and D Technical Report P3-070/TR). This work came to broadly the same conclusion as the work by CEFAS, that an individual dose method is probably the most appropriate method to use. This research and that undertaken by CEFAS will help the total retrospective dose assessment working group refine a set of principles and a methodology for the

  3. The effect of low dose ionizing radiation on homeostasis and functional integrity in an organotypic human skin model

    Energy Technology Data Exchange (ETDEWEB)

    Neubeck, Claere von [German Cancer Consortium DKTK partner site Dresden, OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, 01307 Dresden (Germany); German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Geniza, Matthew J. [Molecular and Cellular Biology Program, Oregon State University, Corvallis OR 97331 (United States); Kauer, Paula M.; Robinson, R. Joe; Chrisler, William B. [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland WA 99352 (United States); Sowa, Marianne B., E-mail: marianne.sowa@pnnl.gov [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland WA 99352 (United States)

    2015-05-15

    Highlights: • Low doses of high LET radiation influence skin homeostasis. • Effects on proliferation and differentiation profiles are LET dependent. • Skin barrier function is not compromised following low dose exposure. - Abstract: Outside the protection of Earth's atmosphere, astronauts are exposed to low doses of high linear energy transfer (LET) radiation. Future NASA plans for deep space missions or a permanent settlement on the moon are limited by the health risks associated with space radiation exposures. There is a paucity of direct epidemiological data for low dose exposures to space radiation-relevant high LET ions. Health risk models are used to estimate the risk for such exposures, though these models are based on high dose experiments. There is increasing evidence, however, that low and high dose exposures result in different signaling events at the molecular level, and may involve different response mechanisms. Further, despite their low abundance, high LET particles have been identified as the major contributor to health risk during manned space flight. The human skin is exposed in every external radiation scenario, making it an ideal epithelial tissue model in which to study radiation induced effects. Here, we exposed an in vitro three dimensional (3-D) human organotypic skin tissue model to low doses of high LET oxygen (O), silicon (Si) and iron (Fe) ions. We measured proliferation and differentiation profiles in the skin tissue and examined the integrity of the skin's barrier function. We discuss the role of secondary particles in changing the proportion of cells receiving a radiation dose, emphasizing the possible impact on radiation-induced health issues in astronauts.

  4. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  5. [Oral films as perspective dosage form].

    Science.gov (United States)

    Walicová, Veronika; Gajdziok, Jan

    Oral films, namely buccal mucoadhesive films and orodispersible films represent innovative formulations for administration of a wide range of drugs. Oral films show many advantageous properties and are intended for systemic drug delivery or for local treatment of the oral mucosa. In both cases, the film represents a thin layer, which could be intended to adhere to the oral mucosa by means of mucoadhesion; or to rapid dissolution and subsequent swallowing without the need of liquid intake, in the case of orodispersible films. Main constitutive excipients are film-forming polymers, which must in the case of mucoadhesive forms remain on the mucosa within the required time interval. Oral films are currently available on the pharmaceutical market and could compete with conventional oral dosage forms in the future. oral cavity oral films buccal mucoadhesive films orodispersible films film-forming polymers.

  6. Enalapril dosage in progressive chronic nephropathy

    DEFF Research Database (Denmark)

    Elung-Jensen, Thomas; Heisterberg, Jens; Sonne, Jesper

    2005-01-01

    OBJECTIVE: In chronic renal failure, clearance of enalapril is reduced. Hence, a renoprotective effect may be achieved with lower doses than conventionally used. Since marked inter-patient variation in concentrations of enalaprilat has been shown in patients with renal failure despite equivalent...... dosage of enalapril, a direct comparison of the effect of high versus low plasma concentrations of enalaprilat on the progression of renal failure was undertaken. METHODS: Forty patients with a median glomerular filtration rate (GFR) of 17 (6-35) ml/min/1.73 m2 were studied in an open-label, randomised...... intervals by the plasma clearance of 51Cr-EDTA, and the individual rates of progression of renal failure were calculated as the slope of GFR versus time plot. RESULTS: In the high-concentration group, the median enalaprilat trough concentration was 92.9 ng/ml (21.8-371.0 ng/ml) and in the low...

  7. Study and characterization of an integrated circuit-deposited hydrogenated amorphous silicon sensor for the detection of particles and radiations

    International Nuclear Information System (INIS)

    Despeisse, M.

    2006-03-01

    Next generation experiments at the European laboratory of particle physics (CERN) require particle detector alternatives to actual silicon detectors. This thesis presents a novel detector technology, which is based on the deposition of a hydrogenated amorphous silicon sensor on top of an integrated circuit. Performance and limitations of this technology have been assessed for the first time in this thesis in the context of particle detectors. Specific integrated circuits have been designed and the detector segmentation, the interface sensor-chip and the sensor leakage current have been studied in details. The signal induced by the track of an ionizing particle in the sensor has been characterized and results on the signal speed, amplitude and on the sensor resistance to radiation are presented. The results are promising regarding the use of this novel technology for radiation detection, though limitations have been shown for particle physics application. (author)

  8. Revitalized citizen projects for Fukushima's radiation and nuclear disaster issues and introduction of the integrated programs relative to radiation education, exercise guidance, and development support at Tokushima University

    International Nuclear Information System (INIS)

    Sakama, Minoru; Nakayama, Shintaro; Saze, Takuya

    2017-01-01

    As for the purpose of this project, 'Revitalized Residential Projects for Fukushima's Radiological and Nuclear Disaster Issues at Tokushima University', the organization of the special mission which is constructed in staffs with volunteer sprits at universities and research facilities have collaborated together with elementary and junior high school teachers and the local government at the revitalized areas in Fukushima. They have built and practiced the new learning education model to bring up the children in there who are not defeated by uneasiness and the rumor of the radiation pollutions relative to the nuclear disaster of Fukushima Dai-ichi Nuclear Power Plant. For children carrying the future only at Fukushima but also in Japan, we bring up hope and the smile of them by coordinating their education to feed the resistance from an early stage to every rumor. By carrying on it we have set up with an integrated goal of getting that we can breed vitality and relief of the whole local community. Our radiation hazard support team at Tokushima University worked on urgent radiation exposure screening at Fukushima from the beginning of earthquake disaster. We had worked on support activities such as the radiation protection education, and also made efforts for the uneasiness reduction of citizens and reducing burdens on the local government. Until now we have kept up with working on the medium-and-long term trials of uneasiness reductions due to radiation properties and radiation hazards for local inhabitants and staffs such as any companies and the local government through practicing these programs, civilian learning society, staff learning society, learning society and counselling for mother and the child, radiation measurement, decontamination advice, and radioactivity measurement support, in particular, at Shirakawa City located as the doorway city of Tohoku area. This report introduces an outline of collaborated programs that we have developed in this project

  9. Radiations

    International Nuclear Information System (INIS)

    Pujol Mora, J.

    1999-01-01

    The exposition to ionizing radiations is a constant fact in the life of the human being and its utilization as diagnostic and therapeutic method is generalized. However, it is notorious how as years go on, the fear to the ionizing radiation seems to persist too, and this fact is not limited to the common individual, but to the technical personnel and professional personnel that labors with them same. (S. Grainger) [es

  10. Radiation

    International Nuclear Information System (INIS)

    Davidson, J.H.

    1986-01-01

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  11. Intensity Modulated Radiation Therapy with Simultaneously Integrated Boost at University Hospital Centre Zagreb (KBC Zagreb)

    International Nuclear Information System (INIS)

    Barisic, L.; Bibic, J.; Grego, T.; Hrsak, H.; Kovacevic, N.

    2013-01-01

    Intensity Modulated Radiation Therapy technique (IMRT) is state of art in modern radiotherapy for bilateral Head and Neck (H and N) malignancies. IMRT of real patients is implemented at KBC Zagreb since June 2012. Our method is inspired partly by Hull IMRT technique. It differs from standard IMRT beam layout (7 beams, gantry angles in 51° steps) and it avoids direct irradiation of OARs. We also use simultaneous integrated boost (SIB IMRT) fractionation. The aim of this paper is to present in some details the whole process of our SIB IMRT including plan quality assurance. Results for several patients together with comparison with ConPas and standard IMRT are presented. In our department, in last several years, routine method for H and N cancer RT was ConPas. During this period we (together with ConPas plans) produced standard IMRT plans with seven equidistant fields for actual patients. Our comparative analysis showed clear superiority of IMRT over ConPas for H and N radiotherapy. Since spring 2012 we have produced also non-standard IMRT plans that are based on Hull (U.K.) experience, with beam gantry angles at 0, 50, 80, 150, 210, 280 and 310 degrees. Also, in this method, direct irradiation of OARs (particularly spinal cord) is avoided by shielding as initial constraint. This approach proved to be better than standard IMRT in all analyzed cases. Having all this in mind, we decided to implement 'our' IMRT technique on real patients. Second essential point of our method is SIB fractionation. It has dosimetric, logistic and radiobiological advantages over standard fractionation. IMRT plan QA is routinely performed using Seven29 and Gamma index method. We take 3 mm/3 % Gamma index and 85 % of passed points as passing rate.(author)

  12. Evaluation of integrity of radiation sources of nuclear gauges; Avaliacao da integridade de fontes radioativas de medidores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Torohate, Wiclif Francisco

    2016-11-01

    Nuclear equipment meters are mainly used in the industry in quality control and process control. The principle of operation consists in a shielded radioactive source together with a radiation detector such that the radiation interacts with the material to be analyzed before reaching the detector, providing real time data. Can be as their fixed and mobile mobility, the unique properties of ionizing radiation are used in three basic modes, transmission, backscatter or dispersion or induced (reactive). With the advancement and technological modernization in the world, the demand for nuclear gauges becomes increasingly larger. Currently in Brazil there are about 465 process control plants and 21 portable systems and Mozambique about 45 facilities using nuclear gauges. This font registration is done through a process called source inventory that allows also to know the category of the source, the danger or risk to human health that the source offers. The handling of this equipment requires personnel, certified, skilled and well trained in radiation protection area in accordance with the requirements of the various CNEN Rules. Due to the presence of radioactive source and because these devices are used by workers risk because there external radiation. In this context, we made the smear test in two fixed meters from the IRD industry laboratory, which determines the integrity of the source package, mandatory item in periodic integrity testing of the radiation source of this type of device. A set of procedures is made for its implementation as an evaluation of the radiological risk by radiological survey. It was intended to contribute to the learning handling and safe use of these meters. (author)

  13. Radiation

    International Nuclear Information System (INIS)

    Winther, J.F.; Ulbak, K.; Dreyer, L.; Pukkala, E.; Oesterlind, A.

    1997-01-01

    Exposure to solar and ionizing radiation increases the risk for cancer in humans. Some 5% of solar radiation is within the ultraviolet spectrum and may cause both malignant melanoma and non-melanocytic skin cancer; the latter is regarded as a benign disease and is accordingly not included in our estimation of avoidable cancers. Under the assumption that the rate of occurrence of malignant melanoma of the buttocks of both men and women and of the scalp of women would apply to all parts of the body in people completely unexposed to solar radiation, it was estimated that approximately 95% of all malignant melanomas arising in the Nordic populations around the year 2000 will be due to exposure to natural ultraviolet radiation, equivalent to an annual number of about 4700 cases, with 2100 in men and 2600 in women, or some 4% of all cancers notified. Exposure to ionizing radiation in the Nordic countries occurs at an average effective dose per capita per year of about 3 mSv (Iceland, 1.1 mSv) from natural sources, and about 1 mSv from man-made sources. While the natural sources are primarily radon in indoor air, natural radionuclides in food, cosmic radiation and gamma radiation from soil and building materials, the man-made sources are dominated by the diagnostic and therapeutic use of ionizing radiation. On the basis of measured levels of radon in Nordic dwellings and associated risk estimates for lung cancer derived from well-conducted epidemiological studies, we estimated that about 180 cases of lung cancer (1% of all lung cancer cases) per year could be avoided in the Nordic countries around the year 2000 if indoor exposure to radon were eliminated, and that an additional 720 cases (6%) could be avoided annually if either radon or tobacco smoking were eliminated. Similarly, it was estimated that the exposure of the Nordic populations to natural sources of ionizing radiation other than radon and to medical sources will each give rise to an annual total of 2120

  14. Improving degradation of paracetamol by integrating gamma radiation and Fenton processes.

    Science.gov (United States)

    Cruz-González, Germán; Rivas-Ortiz, Iram B; González-Labrada, Katia; Rapado-Paneque, Manuel; Chávez-Ardanza, Armando; Nuevas-Paz, Lauro; Jáuregui-Haza, Ulises J

    2016-10-14

    Degradation of paracetamol (N-(4-hydroxiphenyl)acetamide) in aqueous solution by gamma radiation, gamma radiation/H2O2 and gamma radiation/Fenton processes was studied. Parameters affecting the radiolysis of paracetamol such as radiation dose, initial concentration of pollutant, pH and initial oxidant concentration were investigated. Gamma radiation was performed using a (60)Co source irradiator. Paracetamol degradation and mineralization increased with increasing absorbed radiation dose, but decreased with increasing initial concentration of the drug in aqueous solution. The addition of H2O2 resulted in an increased effect on irradiation-driven paracetamol degradation in comparison with the performance of the irradiation-driven process alone: paracetamol removal increased from 48.9% in the absence of H2O2 to 95.2% for H2O2 concentration of 41.7 mmol/L. However, the best results were obtained with gamma radiation/Fenton process with 100% of the drug removal at 5 kGy, for optimal H2O2 and Fe(2+) concentrations at 13.9 and 2.3 mmol/L, respectively, with a high mineralization of 63.7%. These results suggest gamma radiation/H2O2 and gamma radiation/Fenton processes as promising methods for paracetamol degradation in polluted wastewaters.

  15. A boundary integral equation method using auxiliary interior surface approach for acoustic radiation and scattering in two dimensions.

    Science.gov (United States)

    Yang, S A

    2002-10-01

    This paper presents an effective solution method for predicting acoustic radiation and scattering fields in two dimensions. The difficulty of the fictitious characteristic frequency is overcome by incorporating an auxiliary interior surface that satisfies certain boundary condition into the body surface. This process gives rise to a set of uniquely solvable boundary integral equations. Distributing monopoles with unknown strengths over the body and interior surfaces yields the simple source formulation. The modified boundary integral equations are further transformed to ordinary ones that contain nonsingular kernels only. This implementation allows direct application of standard quadrature formulas over the entire integration domain; that is, the collocation points are exactly the positions at which the integration points are located. Selecting the interior surface is an easy task. Moreover, only a few corresponding interior nodal points are sufficient for the computation. Numerical calculations consist of the acoustic radiation and scattering by acoustically hard elliptic and rectangular cylinders. Comparisons with analytical solutions are made. Numerical results demonstrate the efficiency and accuracy of the current solution method.

  16. Relating Radiative Fluxes on Arctic Sea Ice Area Using Arctic Observation and Reanalysis Integrated System (ArORIS)

    Science.gov (United States)

    Sledd, A.; L'Ecuyer, T. S.

    2017-12-01

    With Arctic sea ice declining rapidly and Arctic temperatures rising faster than the rest of the globe, a better understanding of the Arctic climate, and ice cover-radiation feedbacks in particular, is needed. Here we present the Arctic Observation and Reanalysis Integrated System (ArORIS), a dataset of integrated products to facilitate studying the Arctic using satellite, reanalysis, and in-situ datasets. The data include cloud properties, radiative fluxes, aerosols, meteorology, precipitation, and surface properties, to name just a few. Each dataset has uniform grid-spacing, time-averaging and naming conventions for ease of use between products. One intended use of ArORIS is to assess Arctic radiation and moisture budgets. Following that goal, we use observations from ArORIS - CERES-EBAF radiative fluxes and NSIDC sea ice fraction and area to quantify relationships between the Arctic energy balance and surface properties. We find a discernable difference between energy budgets for years with high and low September sea ice areas. Surface fluxes are especially responsive to the September sea ice minimum in months both leading up to September and the months following. In particular, longwave fluxes at the surface show increased sensitivity in the months preceding September. Using a single-layer model of solar radiation we also investigate the individual responses of surface and planetary albedos to changes in sea ice area. By partitioning the planetary albedo into surface and atmospheric contributions, we find that the atmospheric contribution to planetary albedo is less sensitive to changes in sea ice area than the surface contribution. Further comparisons between observations and reanalyses can be made using the available datasets in ArORIS.

  17. Measurements of integrated direct, diffuse and global ultraviolet-B radiation

    International Nuclear Information System (INIS)

    Utrillas, M.P.; Pedrós, R.; Gandía, S.; Gómez-Amo, J.L.; Estellés, V.; Martínez-Lozano, J.A.

    2015-01-01

    We present the first multiyear set of simultaneous measurements of the global ultraviolet-B radiation and its two components: direct and diffuse. The measurements have been taken with four YES-UVB-1 radiometers: two radiometers to measure the diffuse radiation, one provided with a shadow band and the other with a shadow disk on a Sun tracker; a radiometer to measure the global horizontal radiation; and a Sun-tracking radiometer to measure the direct radiation with an especially designed radiance collimator. The diffuse minute-values measured with both instruments agree within a coefficient correlation of 1.00. The diffuse component represents at least 50% of the global UVB (ultraviolet-B) radiation. The minute values of global UVB irradiance obtained by adding the direct and diffuse components concur with the measured global irradiance. Therefore, the measurement of the direct irradiance enables the estimation of the diffuse component, and gives an insight into the factors that affect its value, especially aerosols. - Highlights: • Simultaneous measurements of global, direct and diffuse UVB (ultraviolet-B) radiation. • The diffuse minute-values are at least 50% of the global ones. • The diffuse measurements are highly correlated to the aerosol load. • The sum of direct + diffuse radiation concur with the measured global.

  18. Design and Fabrication of an Integrated Circuit for Monitoring UV Radiation for Health Physics Applications

    International Nuclear Information System (INIS)

    Nazififard, Mohammad; Faghihi, Reyhaneh; Champiri, Afshin Mahmoudieh; Norov, Enkhbat; Suh, Kune Y.

    2014-01-01

    A particularly important term in the clinical photobiology is the standard erythemal dose (SED), which is a measure of the erythemal effectiveness of a UV exposure. However, both the quality and quantity of the UV radiation are important factors for the UV monitoring. This paper aims to introduce and investigate a UV radiation meter in order to establish its applicability for non-ionizing radiation detection. The ultraviolet (UV) radiation is part of the electromagnetic spectrum. The biological effects of UV radiation vary enormously with wavelength and for this reason the UV spectrum is further divided into three regions: UVA, UVB, and UVC. There is increasing evidence that long wave UV radiation plays a vital role in the pathogenesis of photo-dermatoses such as polymorphous light eruption as well as photo-aging. UVA, UVB, and UVC can all damage collagen fibers and, therefore, accelerate aging of the skin. Both UVA and UVB destroy vitamin A in the skin, which may cause further damage. The quantities of the UV radiation are generally expressed using the radiometric terminology

  19. Design and Fabrication of an Integrated Circuit for Monitoring UV Radiation for Health Physics Applications

    Energy Technology Data Exchange (ETDEWEB)

    Nazififard, Mohammad; Faghihi, Reyhaneh [Kashan Univ., Kashan (Iran, Islamic Republic of); Champiri, Afshin Mahmoudieh [Shahid Chamran Univ., Ahwaz (Iran, Islamic Republic of); Norov, Enkhbat [POSTECH, Pohang (Korea, Republic of); Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    A particularly important term in the clinical photobiology is the standard erythemal dose (SED), which is a measure of the erythemal effectiveness of a UV exposure. However, both the quality and quantity of the UV radiation are important factors for the UV monitoring. This paper aims to introduce and investigate a UV radiation meter in order to establish its applicability for non-ionizing radiation detection. The ultraviolet (UV) radiation is part of the electromagnetic spectrum. The biological effects of UV radiation vary enormously with wavelength and for this reason the UV spectrum is further divided into three regions: UVA, UVB, and UVC. There is increasing evidence that long wave UV radiation plays a vital role in the pathogenesis of photo-dermatoses such as polymorphous light eruption as well as photo-aging. UVA, UVB, and UVC can all damage collagen fibers and, therefore, accelerate aging of the skin. Both UVA and UVB destroy vitamin A in the skin, which may cause further damage. The quantities of the UV radiation are generally expressed using the radiometric terminology.

  20. Nuclides.net: An integrated environment for computations on radionuclides and their radiation

    International Nuclear Information System (INIS)

    Galy, J.; Magill, J.

    2002-01-01

    Full text: The Nuclides.net computational package is of direct interest in the fields of environment monitoring and nuclear forensics. The 'integrated environment' is a suite of computer programs ranging from a powerful user-friendly interface, which allows the user to navigate the nuclide chart and explore the properties of nuclides, to various computational modules for decay calculations, dosimetry and shielding calculations, etc. The main emphasis in Nuclides.net is on nuclear science applications, such as health physics, radioprotection and radiochemistry, rather than nuclear data for which excellent sources already exist. In contrast to the CD-based Nuclides 2000 predecessor, Nuclides.net applications run over the internet on a web server. The user interface to these applications is via a web browser. Information submitted by the user is sent to the appropriate applications resident on the web server. The results of the calculations are returned to the user, again via the browser. The product is aimed at both students and professionals for reference data on radionuclides and computations based on this data using the latest internet technology. It is particularly suitable for educational purposes in the nuclear industry, health physics and radiation protection, nuclear and radiochemistry, nuclear physics, astrophysics, etc. The Nuclides.net software suite contains the following modules/features: a) A new user interface to view the nuclide charts (with zoom features). Additional nuclide charts are based on spin, parity, binding energy etc. b) There are five main applications: (1) 'Decay Engine' for decay calculations of numbers, masses, activities, dose rates, etc. of parent and daughters. (2) 'Dosimetry and Shielding' module allows the calculation of dose rates from both unshielded and shielded point sources. A choice of 10 shield materials is available. (3) 'Virtual Nuclides' allows the user to do decay and dosimetry and shielding calculations on mixtures of

  1. The general 2-D moments via integral transform method for acoustic radiation and scattering

    Science.gov (United States)

    Smith, Jerry R.; Mirotznik, Mark S.

    2004-05-01

    The moments via integral transform method (MITM) is a technique to analytically reduce the 2-D method of moments (MoM) impedance double integrals into single integrals. By using a special integral representation of the Green's function, the impedance integral can be analytically simplified to a single integral in terms of transformed shape and weight functions. The reduced expression requires fewer computations and reduces the fill times of the MoM impedance matrix. Furthermore, the resulting integral is analytic for nearly arbitrary shape and weight function sets. The MITM technique is developed for mixed boundary conditions and predictions with basic shape and weight function sets are presented. Comparisons of accuracy and speed between MITM and brute force are presented. [Work sponsored by ONR and NSWCCD ILIR Board.

  2. 21 CFR 522.1222 - Ketamine hydrochloride injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ketamine hydrochloride injectable dosage forms. 522.1222 Section 522.1222 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... ANIMAL DRUGS § 522.1222 Ketamine hydrochloride injectable dosage forms. ...

  3. 21 CFR 520.1696 - Penicillin oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin oral dosage forms. 520.1696 Section 520.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.1696 Penicillin oral...

  4. 21 CFR 526.1696 - Penicillin intramammary dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin intramammary dosage forms. 526.1696 Section 526.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS INTRAMAMMARY DOSAGE FORMS § 526.1696 Penicillin...

  5. 21 CFR 522.1660 - Oxytetracycline injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline injectable dosage forms. 522.1660 Section 522.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... § 522.1660 Oxytetracycline injectable dosage forms. ...

  6. 21 CFR 520.905 - Fenbendazole oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Fenbendazole oral dosage forms. 520.905 Section 520.905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Fenbendazole oral dosage forms. ...

  7. 21 CFR 520.45 - Albendazole oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Albendazole oral dosage forms. 520.45 Section 520.45 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.45 Albendazole oral...

  8. Latch-up and radiation integrated circuit--LURIC: a test chip for CMOS latch-up investigation

    International Nuclear Information System (INIS)

    Estreich, D.B.

    1978-11-01

    A CMOS integrated circuit test chip (Latch-Up and Radiation Integrated Circuit--LURIC) designed for CMOS latch-up and radiation effects research is described. The purpose of LURIC is (a) to provide information on the physics of CMOS latch-up, (b) to study the layout dependence of CMOS latch-up, and (c) to provide special latch-up test structures for the development and verification of a latch-up model. Many devices and test patterns on LURIC are also well suited for radiation effects studies. LURIC contains 86 devices and related test structures. A 12-layer mask set allows both metal gate CMOS and silicon gate ELA (Extended Linear Array) CMOS to be fabricated. Six categories of test devices and related test structures are included. These are (a) the CD4007 metal gate CMOS IC with auxiliary test structures, (b) ELA CMOS cells, (c) field-aided lateral pnp transistors, (d) p-well and substrate spreading resistance test structures, (e) latch-up test structures (simplified symmetrical latch-up paths), and (f) support test patterns (e.g., MOS capacitors, p + n diodes, MOS test transistors, van der Pauw and Kelvin contact resistance test patterns, etc.). A standard probe pattern array has been used on all twenty-four subchips for testing convenience

  9. Integrative Bioinformatic Analysis of Transcriptomic Data Identifies Conserved Molecular Pathways Underlying Ionizing Radiation-Induced Bystander Effects (RIBE

    Directory of Open Access Journals (Sweden)

    Constantinos Yeles

    2017-11-01

    Full Text Available Ionizing radiation-induced bystander effects (RIBE encompass a number of effects with potential for a plethora of damages in adjacent non-irradiated tissue. The cascade of molecular events is initiated in response to the exposure to ionizing radiation (IR, something that may occur during diagnostic or therapeutic medical applications. In order to better investigate these complex response mechanisms, we employed a unified framework integrating statistical microarray analysis, signal normalization, and translational bioinformatics functional analysis techniques. This approach was applied to several microarray datasets from Gene Expression Omnibus (GEO related to RIBE. The analysis produced lists of differentially expressed genes, contrasting bystander and irradiated samples versus sham-irradiated controls. Furthermore, comparative molecular analysis through BioInfoMiner, which integrates advanced statistical enrichment and prioritization methodologies, revealed discrete biological processes, at the cellular level. For example, the negative regulation of growth, cellular response to Zn2+-Cd2+, and Wnt and NIK/NF-kappaB signaling, thus refining the description of the phenotypic landscape of RIBE. Our results provide a more solid understanding of RIBE cell-specific response patterns, especially in the case of high-LET radiations, like α-particles and carbon-ions.

  10. Integrating Two-Dimensional Nanomaterials and Molecular Dielectrics for Radiation-Hard Non-Volatile Memory

    Data.gov (United States)

    National Aeronautics and Space Administration — The space radiation environment presents a significant hazard to the critical electronic components used in a variety of space applications. Many such applications...

  11. Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

    Energy Technology Data Exchange (ETDEWEB)

    Jungmann-Smith, J. H., E-mail: jsmith@magnet.fsu.edu; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Greiffenberg, D.; Jaggi, A.; Maliakal, D.; Mayilyan, D.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Ruder, Ch.; Schädler, L.; Schmitt, B.; Shi, X.; Tinti, G. [Paul Scherrer Institute, 5232 Villigen PSI (Switzerland); Cartier, S. [Paul Scherrer Institute, 5232 Villigen PSI (Switzerland); Institute for Biomedical Engineering, University and ETHZ, 8092 Zürich (Switzerland); Medjoubi, K. [Synchrotron Soleil, L’Orme des Merisiers, Saint-Aubin–BP 48, 91192 GIF-sur-Yvette Cedex (France)

    2015-12-15

    JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10{sup 4} photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm{sup 2} pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm{sup 2}. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

  12. Blending work-integrated learning with distance education in an Australian radiation therapy advanced practice curriculum

    International Nuclear Information System (INIS)

    Matthews, Kristie; Wright, Caroline; Osborne, Catherine

    2014-01-01

    Advanced practice for radiation therapists has been a part of the international landscape for several years; however formal implementation into the Australian health care system is yet to happen. Despite this, three short course radiation therapy advanced practitioner programs have been established by an Australian tertiary institution in response to clinical service needs at several organisations. This paper describes the rationale for curriculum design and development of the program materials, the small-scale implementation of the programs at pilot sites, and the evolution of the curriculum to be available to registered radiation therapists nationally. Each program has been designed around a specific clinical role, where flexibility of delivery to busy practitioners was central to the decision to offer them via distance education. The curriculum comprises theoretical units of study which run in parallel to and underpin clinical practice units, where advanced competence in the specific area of practice is overseen by an experienced radiation oncologist mentor. Given the nature of the disparate clinical services requiring an advanced radiation therapy practitioner, the workplace learning component of the course is individually negotiated at a local level. Outcomes suggest that the flexible clinically based training underpinned by a distance education academic curriculum is able to support the development of advanced radiation therapy practitioners responsive to local service need, and ultimately may improve the patient experience

  13. Photonic Integrated Circuit (PIC) Device Structures: Background, Fabrication Ecosystem, Relevance to Space Systems Applications, and Discussion of Related Radiation Effects

    Science.gov (United States)

    Alt, Shannon

    2016-01-01

    Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.

  14. Radiation-stable polyolefin compositions

    International Nuclear Information System (INIS)

    Rekers, J.W.

    1986-01-01

    This invention relates to compositions of olefinic polymers suitable for high energy radiation treatment. In particular, the invention relates to olefinic polymer compositions that are stable to sterilizing dosages of high energy radiation such as a gamma radiation. Stabilizers are described that include benzhydrol and benzhydrol derivatives; these stabilizers may be used alone or in combination with secondary antioxidants or synergists

  15. Integration of on-line imaging, plan adaptation and radiation delivery: proof of concept using digital tomosynthesis

    International Nuclear Information System (INIS)

    Mestrovic, Ante; Otto, Karl; Nichol, Alan; Clark, Brenda G

    2009-01-01

    The main objective of this manuscript is to propose a new approach to on-line adaptive radiation therapy (ART) in which daily image acquisition, plan adaptation and radiation delivery are integrated together and performed concurrently. A method is described in which on-line ART is performed based on intra-fractional digital tomosynthesis (DTS) images. Intra-fractional DTS images were reconstructed as the gantry rotated between treatment positions. An edge detection algorithm was used to automatically segment the DTS images as the gantry arrived at each treatment position. At each treatment position, radiation was delivered based on the treatment plan re-optimized for the most recent DTS image contours. To investigate the feasibility of this method, a model representing a typical prostate, bladder and rectum was used. To simulate prostate deformations, three clinically relevant, non-rigid deformations (small, medium and large) were modeled by systematically deforming the original anatomy. Using our approach to on-line ART, the original treatment plan was successfully adapted to arrive at a clinically acceptable plan for all three non-rigid deformations. In conclusion, we have proposed a new approach to on-line ART in which plan adaptation is performed based on intra-fractional DTS images. The study findings indicate that this approach can be used to re-optimize the original treatment plan to account for non-rigid anatomical deformations. The advantages of this approach are 1) image acquisition and radiation delivery are integrated in a single gantry rotation around the patient, reducing the treatment time, and 2) intra-fractional DTS images can be used to detect and correct for patient motion prior to the delivery of each beam (intra-fractional patient motion).

  16. Integration of social aspects in radiation protection. The AIRP Work group on communication

    International Nuclear Information System (INIS)

    Cantone, Marie C.; Magnoni, Mauro; Sturloni, Giancarlo

    2008-01-01

    Radiation protection has never been confined just to its scientific and quantitative aspects as it also incorporates a real and proper social factor. In most developed countries, considerations on the social and ethical issues of radiation protection and discussions on the approaches to stakeholder involvement are in a state of positive turmoil. Scientific and practical experts are identifying and promoting dialogue procedures, embracing ethical and social aspects, and are moving together to add to their experience in new and improved practices for the decision-making process. In early 2006, the Italian Radiation Protection Association (AIRP) set up a workgroup for the purpose of: 1-) Promoting dialogue among RP experts, experts in other disciplines, national and local authorities and the public, in relation to social awareness issues in the fields of ionising and non-ionising radiation protection; 2-) Promoting reflection on the mutual interactions between radiation protection and society; 3-) Contributing to the development and diffusion in the RP community of the culture of stakeholder engagement in the decision-making process. Aiming at promoting continual dialogue between the radiation protection community and society, an initial meeting was held in June 2006 on the fundamentals and objectives of RP communication, by focusing on issues such as: the credibility of information sources, the role of the mass media and institutions in risk communication. A workshop was held in November 2006 on the social aspects of radiation protection: experts in scientific journalism, sociology and medical physics, representatives of consumer associations, participants in a Government task commission, local authorities and representatives of the leading local and national institutions involved in RP, were given the opportunity of communicating and discussing the main socially-sensitive aspects of RP. The work of the AIRP group continued in 2007 with two events related on the

  17. Spectrophotometric Determination of Trimipramine in Tablet Dosage ...

    African Journals Online (AJOL)

    [13,14], which absorb radiation in both ultra-violet and visible ... reaction with trimipramine which has not yet been reported. ..... (D-A) was promoted by the high ionizing power ... derivatized β-cyclodextrins as chiral mobile phase additives.

  18. Thermal Vacuum Test of Ice as a Phase Change Material Integrated with a Radiator

    Science.gov (United States)

    Lee, Steve A.; Leimkuehler, Thomas O.; Stephan, Ryan; Le, Hung V.

    2010-01-01

    Water may be used as radiation shielding for Solar Particle Events (SPE) to protect crewmembers in the Lunar Electric Rover (LER). Because the water is already present for radiation protection, it could also provide a mass efficient solution to the vehicle's thermal control system. This water can be frozen by heat rejection from a radiator and used as a Phase Change Material (PC1V1) for thermal storage. Use of this water as a PCM can eliminate the need for a pumped fluid loop thermal control system as well as reduce the required size of the radiator. This paper describes the testing and analysis performed for the Rover Engineering Development Unit (REDU), a scaled-down version of a water PCM heat sink for the LER. The REDU was tested in a thermal-vacuum chamber at environmental temperatures similar to those of a horizontal radiator panel on the lunar surface. Testing included complete freeze and melt cycles along with scaled transient heat load profiles simulating a 24-hour day for the rover.

  19. Simultaneous integrated boost-intensity modulated radiation therapy for inoperable hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyun; Park, Joong-Won; Kim, Yeon-Joo; Kim, Bo Hyun; Woo, Sang Myung; Moon, Sung Ho; Kim, Sang Soo; Lee, Woo Jin; Kim, Dae Yong; Kim, Chang-Min [National Cancer Center, Center for Liver Cancer, Research Institute and Hospital, Goyang-si, Gyeonggi-do (Korea, Republic of)

    2014-10-15

    The aim of this work was to evaluate the clinical efficacy and safety of simultaneous integrated boost-intensity modulated radiation therapy (SIB-IMRT) in patients with inoperable hepatocellular carcinoma (HCC). A total of 53 patients with inoperable HCC underwent SIB-IMRT using two dose-fractionation schemes, depending on the proximity of gastrointestinal structures. The 41 patients in the low dose-fractionation (LD) group, with internal target volume (ITV) < 1 cm from gastrointestinal structures, received total doses of 55 and 44 Gy in 22 fractions to planning target volume 1 (PTV1) and 2 (PTV2), respectively. The 12 patients in the high dose-fractionation (HD) group, with ITV ≥ 1 cm from gastrointestinal structures, received total doses of 66 and 55 Gy in 22 fractions to the PTV1 and PTV2, respectively. Overall, treatment was well tolerated, with no grade > 3 toxicity. The LD group had larger sized tumors (median: 6 vs. 3.4 cm) and greater frequencies of vascular invasion (80.6 vs. 16.7 %) than patients in the HD group (p < 0.05 each). The median overall survival (OS) was 25.1 months and the actuarial 2-year local progression-free survival (LPFS), relapse-free survival (RFS), and OS rates were 67.3, 14.7, and 54.7 %, respectively. The HD group tended to show better tumor response (100 vs. 62.2 %, p = 0.039) and 2-year LPFS (85.7 vs. 59 %, p = 0.119), RFS (38.1 vs. 7.3 %, p = 0.063), and OS (83.3 vs. 44.3 %, p = 0.037) rates than the LD group. Multivariate analysis showed that tumor response was significantly associated with OS. SIB-IMRT is feasible and safe for patients with inoperable HCC. (orig.) [German] Ziel der Arbeit war es, die klinische Wirksamkeit und die Sicherheit der intensitaetsmodulierten Radiotherapie mit simultanem integriertem Boost (SIB-IMRT) fuer Patienten mit einem inoperablen hepatozellulaeren Karzinom (HCC) zu evaluieren. Bei 53 Patienten mit inoperablem HCC wurden zwei unterschiedliche Dosierungskonzepte je nach Lagebeziehung des

  20. CONCERT. ''European joint programme for the integration of radiation protection research''; CONCERT. Gemeinsame Europaeische Forschungsfoerderung

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt-Hannig, A.; Birschwilks, M.; Jung, T. [Bundesamt fuer Strahlenschutz (Germany)

    2016-07-01

    CONCERT is a joint project of the EU and its member states which assume joint financing: Over the next five years the largest European radiation protection programme so far will have available about 28 Million Euros for research and integrative measures, whereby the European Commission will bear 70 per cent of the costs. Integrative measures include, among others, targeted vocational education and training of junior researchers in radiation protection, better access to research and irradiation facilities for scientists, as well as a stronger connection of universities and research centres in radiation protection research.

  1. Thermal Radiometer Signal Processing Using Radiation Hard CMOS Application Specific Integrated Circuits for Use in Harsh Planetary Environments

    Science.gov (United States)

    Quilligan, G.; DuMonthier, J.; Aslam, S.; Lakew, B.; Kleyner, I.; Katz, R.

    2015-01-01

    Thermal radiometers such as proposed for the Europa Clipper flyby mission require low noise signal processing for thermal imaging with immunity to Total Ionizing Dose (TID) and Single Event Latchup (SEL). Described is a second generation Multi- Channel Digitizer (MCD2G) Application Specific Integrated Circuit (ASIC) that accurately digitizes up to 40 thermopile pixels with greater than 50 Mrad (Si) immunity TID and 174 MeV-sq cm/mg SEL. The MCD2G ASIC uses Radiation Hardened By Design (RHBD) techniques with a 180 nm CMOS process node.

  2. Theory, development and principal application trends of lyoluminescence in integral radiation dosimetry

    International Nuclear Information System (INIS)

    Kubicek, I.

    1984-01-01

    The mechanism of lyoluminescence (LL) of inorganic and organic compounds is described in detail and discussed are the basic characteristics of the LL process, the physico-chemical properties of the system, the principle of measurement and the possibility of increasing the LL yield. Attention is also devoted to the design of evaluation kits developed and used by different laboratories. A substantial part of the study is devoted to the response of LL dosemeters to different types of ionizing radiation (gamma radiation, fast and slow neutrons and heavy charged particles). The high level of tissue equivalence of some organic materials, their sensitivity to gamma radiation and fast neutrons and finally the possible use of human biological tissue as a dosemeter predestinates the LL method for uses mainly in clinical and accident dosimetry. (author)

  3. Radiation effects and soft errors in integrated circuits and electronic devices

    CERN Document Server

    Fleetwood, D M

    2004-01-01

    This book provides a detailed treatment of radiation effects in electronic devices, including effects at the material, device, and circuit levels. The emphasis is on transient effects caused by single ionizing particles (single-event effects and soft errors) and effects produced by the cumulative energy deposited by the radiation (total ionizing dose effects). Bipolar (Si and SiGe), metal-oxide-semiconductor (MOS), and compound semiconductor technologies are discussed. In addition to considering the specific issues associated with high-performance devices and technologies, the book includes th

  4. Integration

    DEFF Research Database (Denmark)

    Emerek, Ruth

    2004-01-01

    Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration......Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration...

  5. The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework

    Energy Technology Data Exchange (ETDEWEB)

    Kratt, Karin [Faculty of Mathematics, Technical University of Kaiserslautern, Kaiserslautern (Germany); Scherrer, Alexander [Department of Optimization, Fraunhofer Institute for Industrial Mathematics (ITWM), Kaiserslautern (Germany)], E-mail: alexander.scherrer@itwm.fraunhofer.de

    2009-06-21

    The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this work addresses the integration of DVH-based planning aspects into this framework from a general point of view. It first provides the basic mathematical requirements on the evaluation functions in order to support such an incorporation. Then it introduces the condition number as a description for how precisely DVH-based planning aspects can be reformulated in terms of evaluation functions. Exemplary numerical studies for the generalized equivalent uniform dose and a physical constraint function show the influence of function parameter values and DVH approximation on the condition number. The work concludes by formulating the aspects that should be taken into account for an appropriate integration of DVH-based planning aspects. (note)

  6. The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework

    International Nuclear Information System (INIS)

    Kratt, Karin; Scherrer, Alexander

    2009-01-01

    The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this work addresses the integration of DVH-based planning aspects into this framework from a general point of view. It first provides the basic mathematical requirements on the evaluation functions in order to support such an incorporation. Then it introduces the condition number as a description for how precisely DVH-based planning aspects can be reformulated in terms of evaluation functions. Exemplary numerical studies for the generalized equivalent uniform dose and a physical constraint function show the influence of function parameter values and DVH approximation on the condition number. The work concludes by formulating the aspects that should be taken into account for an appropriate integration of DVH-based planning aspects. (note)

  7. New development of integrated CT simulation system for radiation therapy planning

    International Nuclear Information System (INIS)

    Kushima, Takeyuki; Kono, Michio

    1993-01-01

    In order to put more accurate radiotherapy into practice, a radiotherapy planning system using CT, which is named CT simulation system, has been developed and introduced at Kobe University Hospital. The CT simulation system consists of a CT scanner, an image processing work-station, and a laser marking system. The target area of radiation is determined on each CT axial image of scout view in the work-station. Three-dimensional treatment planning is feasible on the basis of the two-dimensional tumor information in CT axial images. After setting treatment parameters, the contour of the radiation field on beam's eye view and the iso-center position are calculated by computer. This system makes it possible to choose an appropriate irradiation method and an optimal dose distribution. In the present study we examined the fundamental capability of this system. The laser marking system proved to have a very high degree of accuracy. The outcome of a phantom test raised the strong possibility that this system may be applied clinically. In addition to these basic findings, this paper describes preliminary clinical observations that support the good reproducibility of the radiation field projected with the CT simulator. In conclusion, this system is of high value for radiation therapy planning. (author)

  8. An acoustic radiator with integrated cavity and active control of surface vibration

    NARCIS (Netherlands)

    Berkhoff, Arthur; Tajdari, Farnaz

    2017-01-01

    This paper presents a method to realize an acoustic source for low frequencies with relatively small thickness. A honeycomb plate structure which is open on one side combines the radiating surface and the major part of the air cavity. The vibration of the plate is controlled with a decentralized

  9. Repair-dependent cell radiation survival and transformation: an integrated theory

    International Nuclear Information System (INIS)

    Sutherland, John C

    2014-01-01

    The repair-dependent model of cell radiation survival is extended to include radiation-induced transformations. The probability of transformation is presumed to scale with the number of potentially lethal damages that are repaired in a surviving cell or the interactions of such damages. The theory predicts that at doses corresponding to high survival, the transformation frequency is the sum of simple polynomial functions of dose; linear, quadratic, etc, essentially as described in widely used linear-quadratic expressions. At high doses, corresponding to low survival, the ratio of transformed to surviving cells asymptotically approaches an upper limit. The low dose fundamental- and high dose plateau domains are separated by a downwardly concave transition region. Published transformation data for mammalian cells show the high-dose plateaus predicted by the repair-dependent model for both ultraviolet and ionizing radiation. For the neoplastic transformation experiments that were analyzed, the data can be fit with only the repair-dependent quadratic function. At low doses, the transformation frequency is strictly quadratic, but becomes sigmodial over a wider range of doses. Inclusion of data from the transition region in a traditional linear-quadratic analysis of neoplastic transformation frequency data can exaggerate the magnitude of, or create the appearance of, a linear component. Quantitative analysis of survival and transformation data shows good agreement for ultraviolet radiation; the shapes of the transformation components can be predicted from survival data. For ionizing radiations, both neutrons and x-rays, survival data overestimate the transforming ability for low to moderate doses. The presumed cause of this difference is that, unlike UV photons, a single x-ray or neutron may generate more than one lethal damage in a cell, so the distribution of such damages in the population is not accurately described by Poisson statistics. However, the complete

  10. Integral-equation based methods for parameter estimation in output pulses of radiation detectors: Application in nuclear medicine and spectroscopy

    Science.gov (United States)

    Mohammadian-Behbahani, Mohammad-Reza; Saramad, Shahyar

    2018-04-01

    Model based analysis methods are relatively new approaches for processing the output data of radiation detectors in nuclear medicine imaging and spectroscopy. A class of such methods requires fast algorithms for fitting pulse models to experimental data. In order to apply integral-equation based methods for processing the preamplifier output pulses, this article proposes a fast and simple method for estimating the parameters of the well-known bi-exponential pulse model by solving an integral equation. The proposed method needs samples from only three points of the recorded pulse as well as its first and second order integrals. After optimizing the sampling points, the estimation results were calculated and compared with two traditional integration-based methods. Different noise levels (signal-to-noise ratios from 10 to 3000) were simulated for testing the functionality of the proposed method, then it was applied to a set of experimental pulses. Finally, the effect of quantization noise was assessed by studying different sampling rates. Promising results by the proposed method endorse it for future real-time applications.

  11. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Garcia-Sciveres, M; CERN. Geneva. The LHC experiments Committee; LHCC

    2013-01-01

    Letter of Intent for RD Collaboration Proposal focused on development of a next generation pixel readout integrated circuits needed for high luminosity LHC detector upgrades. Brings together ATLAS and CMS pixel chip design communities.

  12. Combined Helmholtz Integral Equation - Fourier series formulation of acoustical radiation and scattering problems

    CSIR Research Space (South Africa)

    Fedotov, I

    2006-07-01

    Full Text Available The Combined Helmholtz Integral Equation – Fourier series Formulation (CHIEFF) is based on representation of a velocity potential in terms of Fourier series and finding the Fourier coefficients of this expansion. The solution could be substantially...

  13. Does temperature nudging overwhelm aerosol radiative effects in regional integrated climate models?

    Science.gov (United States)

    For over two decades, data assimilation (popularly known as nudging) methods have been used for improving regional weather and climate simulations by reducing model biases in meteorological parameters and processes. Similar practice is also popular in many regional integrated met...

  14. Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios

    International Nuclear Information System (INIS)

    García-Vázquez, V; Marinetto, E; Santos-Miranda, J A; Calvo, F A; Desco, M; Pascau, J

    2013-01-01

    Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios. (paper)

  15. Application of an incident taxonomy for radiation therapy: Analysis of five years of data from three integrated cancer centres.

    Science.gov (United States)

    Greenham, Stuart; Manley, Stephen; Turnbull, Kirsty; Hoffmann, Matthew; Fonseca, Amara; Westhuyzen, Justin; Last, Andrew; Aherne, Noel J; Shakespeare, Thomas P

    2018-01-01

    To develop and apply a clinical incident taxonomy for radiation therapy. Capturing clinical incident information that focuses on near-miss events is critical for achieving higher levels of safety and reliability. A clinical incident taxonomy for radiation therapy was established; coding categories were prescription, consent, simulation, voluming, dosimetry, treatment, bolus, shielding, imaging, quality assurance and coordination of care. The taxonomy was applied to all clinical incidents occurring at three integrated cancer centres for the years 2011-2015. Incidents were managed locally, audited and feedback disseminated to all centres. Across the five years the total incident rate (per 100 courses) was 8.54; the radiotherapy-specific coded rate was 6.71. The rate of true adverse events (unintended treatment and potential patient harm) was 1.06. Adverse events, where no harm was identified, occurred at a rate of 2.76 per 100 courses. Despite workload increases, overall and actual rates both exhibited downward trends over the 5-year period. The taxonomy captured previously unidentified quality assurance failures; centre-specific issues that contributed to variations in incident trends were also identified. The application of a taxonomy developed for radiation therapy enhances incident investigation and facilitates strategic interventions. The practice appears to be effective in our institution and contributes to the safety culture. The ratio of near miss to actual incidents could serve as a possible measure of incident reporting culture and could be incorporated into large scale incident reporting systems.

  16. [Integrity].

    Science.gov (United States)

    Gómez Rodríguez, Rafael Ángel

    2014-01-01

    To say that someone possesses integrity is to claim that that person is almost predictable about responses to specific situations, that he or she can prudentially judge and to act correctly. There is a closed interrelationship between integrity and autonomy, and the autonomy rests on the deeper moral claim of all humans to integrity of the person. Integrity has two senses of significance for medical ethic: one sense refers to the integrity of the person in the bodily, psychosocial and intellectual elements; and in the second sense, the integrity is the virtue. Another facet of integrity of the person is la integrity of values we cherish and espouse. The physician must be a person of integrity if the integrity of the patient is to be safeguarded. The autonomy has reduced the violations in the past, but the character and virtues of the physician are the ultimate safeguard of autonomy of patient. A field very important in medicine is the scientific research. It is the character of the investigator that determines the moral quality of research. The problem arises when legitimate self-interests are replaced by selfish, particularly when human subjects are involved. The final safeguard of moral quality of research is the character and conscience of the investigator. Teaching must be relevant in the scientific field, but the most effective way to teach virtue ethics is through the example of the a respected scientist.

  17. The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

    International Nuclear Information System (INIS)

    Hartwig, Zachary S.

    2016-01-01

    The ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific productivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of C++ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms. - Highlights: • A new software framework for radiation detector data acquisition and analysis. • Integrated acquisition and analysis of real-world and simulated detector data. • C++ and Python libraries for data acquisition hardware control and readout. • Graphical program for control and readout of digital data acquisition hardware. • Graphical program for comprehensive analysis of real-world and simulated data.

  18. The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hartwig, Zachary S., E-mail: hartwig@mit.edu

    2016-04-11

    The ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific productivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of C++ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms. - Highlights: • A new software framework for radiation detector data acquisition and analysis. • Integrated acquisition and analysis of real-world and simulated detector data. • C++ and Python libraries for data acquisition hardware control and readout. • Graphical program for control and readout of digital data acquisition hardware. • Graphical program for comprehensive analysis of real-world and simulated data.

  19. Fourteen days oral administration of therapeutic dosage of some ...

    African Journals Online (AJOL)

    Fourteen days oral administration of therapeutic dosage of some antibiotics reduced serum testosterone in male rats. FO Awobajo, Y Raji, II Olatunji-Bello, FT Kunle-Alabi, AO Adesanya, TO Awobajo ...

  20. Buccal Dosage Forms: General Considerations for Pediatric Patients.

    Science.gov (United States)

    Montero-Padilla, Soledad; Velaga, Sitaram; Morales, Javier O

    2017-02-01

    The development of an appropriate dosage form for pediatric patients needs to take into account several aspects, since adult drug biodistribution differs from that of pediatrics. In recent years, buccal administration has become an attractive route, having different dosage forms under development including tablets, lozenges, films, and solutions among others. Furthermore, the buccal epithelium can allow quick access to systemic circulation, which could be used for a rapid onset of action. For pediatric patients, dosage forms to be placed in the oral cavity have higher requirements for palatability to increase acceptance and therapy compliance. Therefore, an understanding of the excipients required and their functions and properties needs to be particularly addressed. This review is focused on the differences and requirements relevant to buccal administration for pediatric patients (compared to adults) and how novel dosage forms can be less invasive and more acceptable alternatives.

  1. Dosage compensation of serine-4 transfer RNA in Drosophila melanogaster

    International Nuclear Information System (INIS)

    Birchler, J.A.; Owenby, R.K.; Jacobson, K.B.

    1982-01-01

    A dosage series of the X chromosome site for serine-4 transfer RNA consisting of one of three copies in females and one to two in males was constructed to test whether transfer RNA expression is governed by dosage compensation. A dosage effect on the level of the serine-4 isoacceptor was observed in both females and males when the structural locus was varied. However, in males, each dose had a relatively greater expression so the normal one dose was slightly greater than the total female value and the duplicated male had the highest relative expression of all the types examined. Serine-4 levels in males and females from an isogenic Oregon-R stock were similar. Thus the transfer RNA levels conform to the expectations of dosage compensation

  2. Conceptual design of a versatile radiation tolerant integrated signal conditioning circuit for resistive sensors

    Energy Technology Data Exchange (ETDEWEB)

    Leroux, P. [Katholieke Hogeschool Kempen, Kleinhoefstraat 4, B-2440 Geel (Belgium); Katholieke Universiteit Leuven, Dept. ESAT-MICAS, Kasteelpark Arenberg 10, B-3001 Heverlee (Belgium); SCK-CEN, Belgian Nuclear Research Centre, Boeretang 200, B-2400 Mol (Belgium); Sterckx, J. [Katholieke Hogeschool Kempen, Kleinhoefstraat 4, B-2440 Geel (Belgium); Van Uffelen, M.; Damiani, C. [Fusion 4 Energy, Ed. B3, c/Josep, no 2, Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2011-07-01

    This paper presents the design of a radiation tolerant configurable discrete time CMOS signal conditioning circuit for use with resistive sensors like strain gauge pressure sensors. The circuit is intended to be used for remote handling in harsh environments in the International Thermonuclear Experimental fusion Reactor (ITER). The design features a 5 V differential preamplifier using a Correlated Double Sampling (CDS) architecture at a sample rate of 20 kHz and a 24 V discrete time post amplifier. The gain is digitally controllable between 27 and 400 in the preamplifier and between 1 and 8 in the post amplifier. The nominal input referred noise voltage is only 8.5 {mu}V while consuming only 1 mW. The circuit has a simulated radiation tolerance of more than 1 MGy. (authors)

  3. Integration Of A Computerized Radiation Monitoring System Into A Robotic System For 1251 Process Control

    International Nuclear Information System (INIS)

    Osovizky, A.; Paran, J.; Ankry, N.; Ashkenazi, B.; Vulasky, E.; Tal, N.; Mazor, T.; Gihon, R.; Dolev, E.; Tirosh, D.

    1999-01-01

    An 125 I quantity indication system is introduced. 125 I is a radioisotope commonly used in nuclear medicine departments. This radioisotope emits y photons with energy of about 30 keV, with half-life of 60 days. Low energy and long life-time enable to produce 125 I by large quantities due to the relatively easy transportation possibilities, enabling radiation safety and long distribution distance. A unique customized quality control monitoring system was developed by Rotem Industries for a pharmaceutical company. The quality control check is performed on each 125 I vial by measuring its activity with the micro-controller based radiation meter that also determines whether to accept or reject a vial. The meter stores the radioactivity results for documentation and for average processing, in order to indicate the activity filling trend. This trend can be used for a closed feedback loop in order to control and improve the vials filling during production

  4. Integrity of the National Resident Matching Program for Radiation Oncology: National Survey of Applicant Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Holliday, Emma B. [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Thomas, Charles R., E-mail: thomasch@ohsu.edu [Department of Radiation Medicine, OHSU Knight Cancer Institute, Oregon Health and Science University, Portland, Oregon (United States); Kusano, Aaron S. [Department of Radiation Oncology, University of Washington Medical Center, Seattle, Washington (United States)

    2015-07-01

    Purpose: The aim of this study was to examine the experiences of radiation oncology applicants and to evaluate the prevalence of behaviors that may be in conflict with established ethical standards. Methods and Materials: An anonymous survey was sent to all 2013 applicants to a single domestic radiation oncology residency program through the National Resident Matching Program (NRMP). Questions included demographics, survey of observed behaviors, and opinions regarding the interview and matching process. Descriptive statistics were presented. Characteristics and experiences of respondents who matched were compared with those who did not match. Results: Questionnaires were returned by 87 of 171 applicants for a 51% response rate. Eighty-two questionnaires were complete and included for analysis. Seventy-eight respondents (95.1%) reported being asked at least 1 question in conflict with the NRMP code of conduct. When asked where else they were interviewing, 64% stated that this query made them uncomfortable. Forty-five respondents (54.9%) reported unsolicited post-interview contact by programs, and 31 (37.8%) felt pressured to give assurances. Fifteen respondents (18.3%) reported being told their rank position or that they were “ranked to match” prior to Match day, with 27% of those individuals indicating this information influenced how they ranked programs. Half of respondents felt applicants often made dishonest or misleading assurances, one-third reported that they believed their desired match outcome could be improved by deliberately misleading programs, and more than two-thirds felt their rank position could be improved by having faculty from their home institutions directly contact programs on their behalf. Conclusions: Radiation oncology applicants report a high prevalence of behaviors in conflict with written NRMP policies. Post-interview communication should be discouraged in order to enhance fairness and support the professional development of future

  5. Integrity of the National Resident Matching Program for Radiation Oncology: National Survey of Applicant Experiences

    International Nuclear Information System (INIS)

    Holliday, Emma B.; Thomas, Charles R.; Kusano, Aaron S.

    2015-01-01

    Purpose: The aim of this study was to examine the experiences of radiation oncology applicants and to evaluate the prevalence of behaviors that may be in conflict with established ethical standards. Methods and Materials: An anonymous survey was sent to all 2013 applicants to a single domestic radiation oncology residency program through the National Resident Matching Program (NRMP). Questions included demographics, survey of observed behaviors, and opinions regarding the interview and matching process. Descriptive statistics were presented. Characteristics and experiences of respondents who matched were compared with those who did not match. Results: Questionnaires were returned by 87 of 171 applicants for a 51% response rate. Eighty-two questionnaires were complete and included for analysis. Seventy-eight respondents (95.1%) reported being asked at least 1 question in conflict with the NRMP code of conduct. When asked where else they were interviewing, 64% stated that this query made them uncomfortable. Forty-five respondents (54.9%) reported unsolicited post-interview contact by programs, and 31 (37.8%) felt pressured to give assurances. Fifteen respondents (18.3%) reported being told their rank position or that they were “ranked to match” prior to Match day, with 27% of those individuals indicating this information influenced how they ranked programs. Half of respondents felt applicants often made dishonest or misleading assurances, one-third reported that they believed their desired match outcome could be improved by deliberately misleading programs, and more than two-thirds felt their rank position could be improved by having faculty from their home institutions directly contact programs on their behalf. Conclusions: Radiation oncology applicants report a high prevalence of behaviors in conflict with written NRMP policies. Post-interview communication should be discouraged in order to enhance fairness and support the professional development of future

  6. Effect of Radiation Processing as an Integral Part of Safe Recycling Kitchen Waste for Poultry Feed

    International Nuclear Information System (INIS)

    Farag, M.; Diaa El-Din, H.

    2004-01-01

    Kitchen wastes are relevant as a source of organic matter (i.e. protein, carbohydrate, minerals, and vitamins). Several microorganisms break down organic matter into methane, carbon dioxide, and other organic compounds containing sulfur and halogens. Kitchen wastes are valuable whereas they are too hazardous to be rejected into the environment without any attempt to recover and recycle them in a valuable form. Recycling kitchen waste as a feedstuff could have a considerable effect on reducing costs and solving some disposal problems. Treated such wastes with ionizing radiation can make an important contribution to minimize the risk of pathogens and the emission of greenhouse gases. The study was undertaken with two hundred and thirty kitchen waste samples collected from different restaurants in Cairo, Egypt. Effect of radiation treatment at 10 kGy on crude protein, amino acids profile, available lysine and the in-vitro digestibility of kitchen waste protein have been studied. The results suggest that radiation pasteurization of dried kitchen waste has a beneficial effect on recycling of such waste and permits waste to be included in poultry ration without any health hazard and nutritional problem. (author)

  7. Dosage of trace carbon in sodium (1963); Dosage de traces de carbone dans le sodium (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Sannier, J; Vasseur, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    A wet method for dosing carbon in sodium has been developed. The carbon is oxidised in a vacuum using Van SLYKE'S solution. The carbonic acid formed is measured volumetrically; its purity can be controlled by chromatographic analysis. The results obtained show that this method makes it possible to measure carbon in concentrations of about 10 ppm. (authors) [French] Une methode de dosage par voie humide du carbone dans le sodium a ete mise au point. L'oxydation du carbone par la solution de Van SLYKE est realisee sous vide. Le gaz carbonique forme est dose volumetriquement; sa purete peut etre controlee par analyse chromatographique. Les resultats obtenus montrent que cette methode permet de doser des teneurs en carbone de l'ordre de 10 ppm. (auteurs)

  8. Validation of radiation dose estimations in VRdose: comparing estimated radiation doses with observed radiation doses

    International Nuclear Information System (INIS)

    Nystad, Espen; Sebok, Angelia; Meyer, Geir

    2004-04-01

    The Halden Virtual Reality Centre has developed work-planning software that predicts the radiation exposure of workers in contaminated areas. To validate the accuracy of the predicted radiation dosages, it is necessary to compare predicted doses to actual dosages. During an experimental study conducted at the Halden Boiling Water Reactor (HBWR) hall, the radiation exposure was measured for all participants throughout the test session, ref. HWR-681 [3]. Data from this experimental study have also been used to model tasks in the work-planning software and gather data for predicted radiation exposure. Two different methods were used to predict radiation dosages; one method used all radiation data from all the floor levels in the HBWR (all-data method). The other used only data from the floor level where the task was conducted (isolated data method). The study showed that the all-data method gave predictions that were on average 2.3 times higher than the actual radiation dosages. The isolated-data method gave predictions on average 0.9 times the actual dosages. (Author)

  9. Characterisation of lung tumour under dosage for interpretation of clinical trial data

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dunn, L.; Franich, R.D.; Kron, T.; Height, F.

    2010-01-01

    Full text: It is well known that the periphery of lung tumours is under-dosed in radiotherapy as a result of electronic disequilibrium at the interface of lung and tumour tissue. Clinical trials often employ dose calculation algorithms which poorly approximate the dose to peripheral regions of tumour volumes. The aim of this study was to develop a set of systematic under-dosage estimates corresponding to various clinical parameters. High resolution Monte Carlo radiation transport calculations were undertaken for a systematic set of generic lung tumours irradiated with an external photon beam. Varied parameters include beam energy, field size, tumour size and distance to chest wall. Calculations were undertaken using both EGSnrc and GEAI T4. A 'Dose Reduction Factor' is defined which describes the dose to the peripheral 'shell' 01 the tumour, as relevant for multiple-field and arc therapy. For a 6 MV beam, under-dosage is typically between 2 and 5% for the different arrangements investigated, and for a 15 MV beam it is between 5 and 8% (relative to the central dose). Good agreement between EGSnrc and GEANT4 was demonstrated. Comparisons with pencil beam convolution calculations indicate that the treatment planning system does not identify this under-dosage. A systematic set of data has been obtained that characterises the extent of peripheral under-dosage in lung tumours for the retrospective evaluation of clinical trial data. The data presented i: also informative for clinics using less sophisticated planning algorithms, particularly when dose is being prescribed to covering isodoses. (author)

  10. Alarm radiation dosimeter with improved integrating pulse ionization chamber and high voltage supply

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Rochelle, J.M.

    1975-01-01

    An alarm dosimeter is described which features an improved integrating pulse ionization chamber of the type containing an hermetically sealed gas diode. Improved operation and miniaturization of the chamber are made possible by a ringing choke converter high voltage supply having a ripple-type output that insures discharge of the gas diode. (author)

  11. Integrating electromagnetic radiation hazard info the unique occupational risk assessment document

    International Nuclear Information System (INIS)

    Demaret, P.; Donati, P.

    2011-01-01

    The number of industrial applications involving electromagnetic waves has significantly increased in recent years. These applications are likely to expose operators to electromagnetic fields exceeding the limits laid down by European Parliament and Council Directive 2004/40/CE of 29 April 2004. A survey has identified the equipment emitting the most radiation and this has been classified into 8 families: resistance welding, magnetization, induction heating, magneto-scopy, dielectric loss welding, electrolysis, magnetic resonance imagery, microwaves. The equipment numbers per family was estimated by a market surveys, which specifically identified several tens of thousands of resistance welding- or magnetization-type machines. This survey enabled us to deduce that at least 100,000 operators in France would be at risk of exposure to electromagnetic fields. An assessment of exposure levels for operators at their workstations was undertaken for each equipment family. A group comprising specialists from INRS and the 9 CARSAT/CRAM Physical Measurement Centres measured electromagnetic fields at 635 workstations fitted with radiation emitting machinery. For each measurement, a severity index corresponding to the ratio of the measured value to the action-triggering value (ATV) recommended by European Parliament and Council Directive 2004/40/CE of 29 April 2004 was calculated. The results show that, for 7 equipment families out of the 8 retained, 25 - 50% of measurements gave electromagnetic field values exceeding the corresponding ATV. These results demonstrate the need for prevention means. In most cases, exposure reduction is achieved by moving the workstation away from the radiation source. Technical solutions do exist for certain equipments, such as shielding for microwave ovens and high-frequency presses, a grounding pad for tarpaulin welding, etc. (authors)

  12. Data systems for science integration within the Atmospheric Radiation Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Gracio, D.K.; Hatfield, L.D.; Yates, K.R.; Voyles, J.W. [Pacific Northwest Lab., Richland, WA (United States); Tichler, J.L. [Brookhaven National Lab., Upton, NY (United States); Cederwall, R.T.; Laufersweiler, M.J.; Leach, M.J. [Lawrence Livermore National Lab., CA (United States); Singley, P. [Oak Ridge National Lab., TN (United States)

    1995-12-31

    The Atmospheric Radiation Measurement (ARM) Program was developed by the US Department of Energy to support the goals and mission of the US Global Change Research Program. The purpose of the ARM program is to improve the predictive capabilities of General Circulation Models (GCMs) in their treatment of clouds and radiative transfer effects. Three experimental testbeds were designed for the deployment of instruments to collect atmospheric data used to drive the GCMs. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in early 1996 in the Tropical Western Pacific (TWP) and in 1997 on the North Slope of Alaska (NSA). Approximately 1.5 GB of data are transferred per day via the Internet from the CART sites, and external data sources to the ARM Experiment Center (EC) at Pacific Northwest Laboratory in Richland, Washington. The Experimental Center is central to the ARM data path and provides for the collection, processing, analysis and delivery of ARM data. Data from the CART sites from a variety of instrumentation, observational systems and from external data sources are transferred to the Experiment Center. The EC processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while maintaining a three-month running archive of data.

  13. Integrated radiation and ecological assessment of both environment and living and working places

    International Nuclear Information System (INIS)

    Konoplya, E.F.; Lobanok, L.M.

    1997-01-01

    Are given the results of researches carried out in Belarus in 1996 on the following directions: study of radionuclides behaviour dynamics in an environment (air, water, ground), ecosystems and populated areas; optimization of system of radiation ecological monitoring in the republic as well as scientific methodological and methodical methods of its realization; study of effects of low doze irradiation; research of a role of chemical and other factors in occurrence and current of pathological states on a background of chronic low doze irradiation; radiobiological and radioecological consequences of the Chernobyl accident

  14. Evaluation of students' knowledge about paediatric dosage calculations.

    Science.gov (United States)

    Özyazıcıoğlu, Nurcan; Aydın, Ayla İrem; Sürenler, Semra; Çinar, Hava Gökdere; Yılmaz, Dilek; Arkan, Burcu; Tunç, Gülseren Çıtak

    2018-01-01

    Medication errors are common and may jeopardize the patient safety. As paediatric dosages are calculated based on the child's age and weight, risk of error in dosage calculations is increasing. In paediatric patients, overdose drug prescribed regardless of the child's weight, age and clinical picture may lead to excessive toxicity and mortalities while low doses may delay the treatment. This study was carried out to evaluate the knowledge of nursing students about paediatric dosage calculations. This research, which is of retrospective type, covers a population consisting of all the 3rd grade students at the bachelor's degree in May, 2015 (148 students). Drug dose calculation questions in exam papers including 3 open ended questions on dosage calculation problems, addressing 5 variables were distributed to the students and their responses were evaluated by the researchers. In the evaluation of the data, figures and percentage distribution were calculated and Spearman correlation analysis was applied. Exam question on the dosage calculation based on child's age, which is the most common method in paediatrics, and which ensures right dosages and drug dilution was answered correctly by 87.1% of the students while 9.5% answered it wrong and 3.4% left it blank. 69.6% of the students was successful in finding the safe dose range, and 79.1% in finding the right ratio/proportion. 65.5% of the answers with regard to Ml/dzy calculation were correct. Moreover, student's four operation skills were assessed and 68.2% of the students were determined to have found the correct answer. When the relation among the questions on medication was examined, a significant relation (correlation) was determined between them. It is seen that in dosage calculations, the students failed mostly in calculating ml/dzy (decimal). This result means that as dosage calculations are based on decimal values, calculations may be ten times erroneous when the decimal point is placed wrongly. Moreover, it

  15. A benefit/risk approach towards selecting appropriate pharmaceutical dosage forms - an application for paediatric dosage form selection.

    Science.gov (United States)

    Sam, Tom; Ernest, Terry B; Walsh, Jennifer; Williams, Julie L

    2012-10-05

    The design and selection of new pharmaceutical dosage forms involves the careful consideration and balancing of a quality target product profile against technical challenges and development feasibility. Paediatric dosage forms present particular complexity due to the diverse patient population, patient compliance challenges and safety considerations of this vulnerable population. This paper presents a structured framework for assessing the comparative benefits and risks of different pharmaceutical design options against pre-determined criteria relating to (1) efficacy, (2) safety and (3) patient access. This benefit/risk framework has then been applied to three hypothetical, but realistic, scenarios for paediatric dosage forms in order to explore its utility in guiding dosage form design and formulation selection. The approach allows a rigorous, systematic and qualitative assessment of the merits and disadvantages of each dosage form option and helps identify mitigating strategies to modify risk. The application of a weighting and scoring system to the criteria depending on the specific case could further refine the analysis and aid decision-making. In this paper, one case study is scored for illustrative purposes. However, it is acknowledged that in real development scenarios, the generation of actual data considering the very specific situation for the patient/product/developer would come into play to drive decisions on the most appropriate dosage form strategy. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  17. Parental genome dosage imbalance deregulates imprinting in Arabidopsis.

    Directory of Open Access Journals (Sweden)

    Pauline E Jullien

    2010-03-01

    Full Text Available In mammals and in plants, parental genome dosage imbalance deregulates embryo growth and might be involved in reproductive isolation between emerging new species. Increased dosage of maternal genomes represses growth while an increased dosage of paternal genomes has the opposite effect. These observations led to the discovery of imprinted genes, which are expressed by a single parental allele. It was further proposed in the frame of the parental conflict theory that parental genome imbalances are directly mirrored by antagonistic regulations of imprinted genes encoding maternal growth inhibitors and paternal growth enhancers. However these hypotheses were never tested directly. Here, we investigated the effect of parental genome imbalance on the expression of Arabidopsis imprinted genes FERTILIZATION INDEPENDENT SEED2 (FIS2 and FLOWERING WAGENINGEN (FWA controlled by DNA methylation, and MEDEA (MEA and PHERES1 (PHE1 controlled by histone methylation. Genome dosage imbalance deregulated the expression of FIS2 and PHE1 in an antagonistic manner. In addition increased dosage of inactive alleles caused a loss of imprinting of FIS2 and MEA. Although FIS2 controls histone methylation, which represses MEA and PHE1 expression, the changes of PHE1 and MEA expression could not be fully accounted for by the corresponding fluctuations of FIS2 expression. Our results show that parental genome dosage imbalance deregulates imprinting using mechanisms, which are independent from known regulators of imprinting. The complexity of the network of regulations between expressed and silenced alleles of imprinted genes activated in response to parental dosage imbalance does not support simple models derived from the parental conflict hypothesis.

  18. Failure of the integrated circuits involving complementary MOS transistors under thermal and ionizing radiation stresses

    International Nuclear Information System (INIS)

    Sarrabayrouse, G.; Rossel, P.; Buxo, J.; Vialaret, G.

    Some criteria for reliability and sorting of complementary MOS transistor integrated circuits are proposed, that take account for special environmental stresses near plane reactors or nuclear reactor cores. An analysis of the damaging causes for these circuits at high and low temperatures is proposed, results obtained on the evolution of these devices under irradiation and irradiation behaviors are discussed. The whole set of experiments has been carried out on CD 4007 AD(K) circuits [fr

  19. Data management and scientific integration within the Atmospheric Radiation Measurement Program

    Science.gov (United States)

    Gracio, Deborah K.; Hatfield, Larry D.; Yates, Kenneth R.; Voyles, Jimmy W.; Tichler, Joyce L.; Cederwall, Richard T.; Laufersweiler, Mark J.; Leach, Martin J.; Singley, Paul

    1995-01-01

    The Atmospheric Radiation Measurement (ARM) Program has been developed by the U.S. Department of Energy with the goal to improve the predictive capabilities of General Circulation Models (GCM's) in their treatment of clouds and radiative transfer effects. To achieve this goal, three experimental testbeds were designed for the deployment of instruments that will collect atmospheric data used to drive the GCM's. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in September 1995 in the Tropical Western Pacific and in 1997 on the North Slope of Alaska. Approximately 400 MB of data are transferred per day via the Internet from the SGP site to the ARM Experiment Center at Pacific Northwest Laboratory in Richland, Washington. The Experiment Center is central to the ARM data path and provides for the collection, processing, analysis, and delivery of ARM data. Data are received from the CART sites from a variety of instrumentation, observational systems, amd external data sources. The Experiment Center processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while providing a three-month running archive of data. A primary requirement of the ARM Program is to preserve and protect all data produced or acquired. This function is performed at Oak Ridge National Laboratory where leading edge technology is employed for the long-term storage of ARM data. The ARM Archive provides access to data for participation outside of the ARM Program. The ARM Program involves a collaborative effort by teams from various DOE National Laboratories, providing multi-disciplinary areas of expertise. This paper will discuss the collaborative methods in which the ARM teams

  20. Experimental validation of alternate integral-formulation method for predicting acoustic radiation based on particle velocity measurements.

    Science.gov (United States)

    Ni, Zhi; Wu, Sean F

    2010-09-01

    This paper presents experimental validation of an alternate integral-formulation method (AIM) for predicting acoustic radiation from an arbitrary structure based on the particle velocities specified on a hypothetical surface enclosing the target source. Both the normal and tangential components of the particle velocity on this hypothetical surface are measured and taken as the input to AIM codes to predict the acoustic pressures in both exterior and interior regions. The results obtained are compared with the benchmark values measured by microphones at the same locations. To gain some insight into practical applications of AIM, laser Doppler anemometer (LDA) and double hotwire sensor (DHS) are used as measurement devices to collect the particle velocities in the air. Measurement limitations of using LDA and DHS are discussed.

  1. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zeniya, T.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T

    2001-07-21

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  2. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Science.gov (United States)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  3. RD Collaboration Proposal: Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Chistiansen, J (CERN)

    2013-01-01

    This proposal describes a new RD collaboration to develop the next genrration of hybrid pixel readout chips for use in ATLAS and CMS PHase 2 upgrades. extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. Challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm2 ), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. This collaboration is specifically focused on design of hybrid pixel readout chips, and not on more general chip design or on other aspects of hybrid pixel technology. Participants include 7 institutes on ATLAS and 7 on CMS, plus 2 on both experiments.

  4. TH-EF-207A-07: An Integrated X-Ray/bioluminescence Tomography System for Radiation Guidance and Tumor Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Shi, J; Udayakumar, T; Wang, Z; Dogan, N; Pollack, A; Yang, Y [University of Miami School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: CT is not able to differentiate tumors from surrounding soft tissue. This study is to develop a bioluminescence tomography (BLT) system that is integrated onto our previously developed CT guided small animal arc radiation treatment system (iSMAART) to guide radiation, monitor tumor growth and evaluate therapeutic response. Methods: The BLT system employs a CCD camera coupled with a high speed lens, and is aligned orthogonally to the x-ray beam central axis. The two imaging modalities, CT and BLT, are physically registered through geometrical calibration. The CT anatomy provides an accurate contour of animal surface which is used to construct 3D mesh for BLT reconstruction. Bioluminescence projections are captured from multiple angles, once every 45 degree rotation. The diffusion equation based on analytical Kirchhoff approximation is adopted to model the photon propagation in tissues. A discrete cosine transform based reweighted L1-norm regularization (DCT-re-L1) algorithm is used for BLT reconstruction. Experiments are conducted on a mouse orthotopic prostate tumor model (n=12) to evaluate the BLT performance, in terms of its robustness and accuracy in locating and quantifying the bioluminescent tumor cells. Iodinated contrast agent was injected intravenously to delineate the tumor in CT. The tumor location and volume obtained from CT also serve as a benchmark against BLT. Results: With our cutting edge reconstruction algorithm, BLT is able to accurately reconstruct the orthotopic prostate tumors. The tumor center of mass in BLT is within 0.5 mm radial distance of that in CT. The tumor volume in BLT is significantly correlated with that in CT (R2 = 0.81). Conclusion: The BLT can differentiate, localize and quantify tumors. Together with CT, BLT will provide precision radiation guidance and reliable treatment assessment in preclinical cancer research.

  5. Effects of total integrated solar radiation on radial fruit cracking in tomato [Lycopersicon esculentum] cultivation under rain shelter in cool uplands

    International Nuclear Information System (INIS)

    Suzuki, T.; Yanase, S.; Enya, T.; Shimazu, T.; Tanaka, I.

    2007-01-01

    This study investigated the cause of radial fruit cracking in tomato cultivation under rain shelter in the cool uplands in Gifu Prefecture. The effect of total integrated radiation using two types of training methods was determined over a three-year period. The percentage of refused radial fruit cracking associated with increased total integrated solar radiation from the young fruit stage to the mature green stage. Fruit cracking occurred in the training method which foliage and fruits received a large amount of light-interception. Also, as for fruits that undergo vigorous enlargement, the frequency of the radial fruit cracking increased

  6. New applications to computerized tomography: analysis of solid dosage forms produced by pharmaceutical industry

    International Nuclear Information System (INIS)

    Oliveira Junior, Jose Martins de; Martins, Antonio Cesar Germano

    2009-01-01

    Full text: In recent years, computerized tomography (CT) has been used as a new probe to study solid dosage forms (tablets) produced by pharmaceutical industry. This new approach to study tablet and powder, or granulation, properties used in pharmaceutical industry is very suitable. First because CT can generate information that traditional technologies used in this kind of analysis can not, such as, density distribution of internal structures and tablet dimensions, pore size distribution, particle shape information, and also investigation of official and unofficial (counterfeit) copies of solid dosage forms. Second because CT is a nondestructive technique, allowing the use of tablets or granules in others analysis. In this work we discus how CT can be used to acquire and reconstruct internal microstructure of tablets and granules. CT is a technique that is based on attenuation of X-rays passing through matter. Attenuation depends on the density and atomic number of the material that is scanned. In this work, a micro-CT X-ray scanner (manufactured by the group of Applied Nuclear Physics at University of Sorocaba) was used to obtain three-dimensional images of the tablets and granules for nondestructive analysis. These images showed a non uniform density distribution of material inside some tablets, the morphology of some granules analyzed, the integrity of the liquid-filled soft-gelatin capsule and so on. It could also be observed that the distribution of different constituents presents an osmotic controlled-release dosage form. The present work shows that it is possible to use X-ray microtomography to obtain useful qualitative and quantitative information on the structure of pharmaceutical dosage forms. (author)

  7. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  8. Feasibility study on low-dosage digital tomosynthesis (DTS) using a multislit collimation technique

    Science.gov (United States)

    Park, S. Y.; Kim, G. A.; Park, C. K.; Cho, H. S.; Seo, C. W.; Lee, D. Y.; Kang, S. Y.; Kim, K. S.; Lim, H. W.; Lee, H. W.; Park, J. E.; Kim, W. S.; Jeon, D. H.; Woo, T. H.

    2018-04-01

    In this study, we investigated an effective low-dose digital tomosynthesis (DTS) where a multislit collimator placed between the X-ray tube and the patient oscillates during projection data acquisition, partially blocking the X-ray beam to the patient thereby reducing the radiation dosage. We performed a simulation using the proposed DTS with two sets of multislit collimators both having a 50% duty cycle and investigated the image characteristics to demonstrate the feasibility of this proposed approach. In the simulation, all projections were taken at a tomographic angle of θ = ± 50° and an angle step of Δθ =2°. We utilized an iterative algorithm based on a compressed-sensing (CS) scheme for more accurate DTS reconstruction. Using the proposed DTS, we successfully obtained CS-reconstructed DTS images with no bright-band artifacts around the multislit edges of the collimator, thus maintaining the image quality. Therefore, the use of multislit collimation in current real-world DTS systems can reduce the radiation dosage to patients.

  9. Conceptual development of a building-integrated photovoltaic–radiative cooling system and preliminary performance analysis in Eastern China

    International Nuclear Information System (INIS)

    Zhao, Bin; Hu, Mingke; Ao, Xianze; Pei, Gang

    2017-01-01

    Highlights: •A specific spectral characteristic for both PV and RC was proposed. •The PV/RC hybrid system based on spectral characteristic is original. •A thermal model of the system was established and the performance was analyzed. •The performance comparison with the conventional PV system was conducted. •The system shows considerable performance for both PV and RC. -- Abstract: Building-integrated photovoltaic/thermal (BIPV/T) technology has been receiving considerable research attention because of its ability to generate electricity and thermal energy simultaneously. However, space cooling is crucial for buildings in hot regions where space heating is of little use. This study proposed a building-integrated photovoltaic–radiative cooling system (BIPV–RC) that can generate electricity via photovoltaic (PV) conversion during daytime and generate cooling energy via radiative cooling (RC) during nighttime to satisfy the demand in such areas. The selective plate, which is the main component of the BIPV–RC system, exhibits high spectral absorptivity (emissivity) in the PV conversion band of crystalline silicon solar cells and in the atmospheric window band (i.e., 0.3–1.1 μm and 8–13 μm), as well as low spectral absorptivity (emissivity) in other bands. A quasi-steady-state mathematical model was built, and its performance under realistic ambient conditions was analyzed. The electrical efficiencies of the BIPV–RC and conventional BIPV systems were then compared under different solar radiations. Comparison results show that the annual electricity production and cooling energy gain of the BIPV–RC system in Hefei reached 156.74 kW h m −2 (equivalent to 564.26 MJ m −2 ) and 579.91 MJ m −2 , respectively. The total electricity production and cooling energy gain of this system are 96.96% higher than those of the BIPV system. Parametric studies show that the precipitable water vapor amount has remarkable effects on the nocturnal RC performance

  10. Optimizing the updated Goddard shortwave radiation Weather Research and Forecasting (WRF) scheme for Intel Many Integrated Core (MIC) architecture

    Science.gov (United States)

    Mielikainen, Jarno; Huang, Bormin; Huang, Allen H.-L.

    2015-05-01

    Intel Many Integrated Core (MIC) ushers in a new era of supercomputing speed, performance, and compatibility. It allows the developers to run code at trillions of calculations per second using the familiar programming model. In this paper, we present our results of optimizing the updated Goddard shortwave radiation Weather Research and Forecasting (WRF) scheme on Intel Many Integrated Core Architecture (MIC) hardware. The Intel Xeon Phi coprocessor is the first product based on Intel MIC architecture, and it consists of up to 61 cores connected by a high performance on-die bidirectional interconnect. The co-processor supports all important Intel development tools. Thus, the development environment is familiar one to a vast number of CPU developers. Although, getting a maximum performance out of Xeon Phi will require using some novel optimization techniques. Those optimization techniques are discusses in this paper. The results show that the optimizations improved performance of the original code on Xeon Phi 7120P by a factor of 1.3x.

  11. New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

    Science.gov (United States)

    Jia, Xun; Tian, Zhen; Xi, Yan; Jiang, Steve B; Wang, Ge

    2017-01-01

    Image guidance plays a critical role in radiotherapy. Currently, cone-beam computed tomography (CBCT) is routinely used in clinics for this purpose. While this modality can provide an attenuation image for therapeutic planning, low soft-tissue contrast affects the delineation of anatomical and pathological features. Efforts have recently been devoted to several MRI linear accelerator (LINAC) projects that lead to the successful combination of a full diagnostic MRI scanner with a radiotherapy machine. We present a new concept for the development of the MRI-LINAC system. Instead of combining a full MRI scanner with the LINAC platform, we propose using an interior MRI (iMRI) approach to image a specific region of interest (RoI) containing the radiation treatment target. While the conventional CBCT component still delivers a global image of the patient's anatomy, the iMRI offers local imaging of high soft-tissue contrast for tumor delineation. We describe a top-level system design for the integration of an iMRI component into an existing LINAC platform. We performed numerical analyses of the magnetic field for the iMRI to show potentially acceptable field properties in a spherical RoI with a diameter of 15 cm. This field could be shielded to a sufficiently low level around the LINAC region to avoid electromagnetic interference. Furthermore, we investigate the dosimetric impacts of this integration on the radiotherapy beam.

  12. Measurements of 14 MeV neutron radiative capture γ-ray spectra and integrated cross sections in Sc, Y, Pr and Ho

    International Nuclear Information System (INIS)

    Budnar, M.; Cvelbar, F.; Likar, A.; Martincic, R.; Potokar, M.; Ivkovic, V.

    1977-01-01

    Gamma ray spectra and integrated cross sections for radiative capture in 45 Sc, 89 Y, 141 Pr and 165 Ho have been measured. Obtained integrated cross sections (800+-110)μb, (1490+-210)μb, (980+-160)μb and (940+-150)μb are in accordance with measurements at other elements showing smooth mass dependence. Measuring procedure and experimental data evaluation is described in details. (author)

  13. ATLAS ABCD Hybrid Fatal Charge Dosage Test

    CERN Document Server

    Kuhl, A; The ATLAS collaboration; Grillo, AA; Martinez-McKinney, F; Nielsen, J; Spencer, E; Wilder, M

    2011-01-01

    The Semi-Conductor Tracker (SCT) in the ATLAS experiment at the Large Hadron Collider (LHC) could be subject to various beam loss scenarios. If a severe beam loss event were to occur, it would be beneficial to know how SCT components would be affected. In the SCT detector modules, a key component is the ABCD application specific integrated circuit (ASIC), the onboard readout electronics of the system. This ASIC has design specifications that it should withstand a 5nC charge injection within 25 ns, which is the period of the LHC bunch crossing. The first test performed is designed to test this limit, reaching a maximum of 10nC deposited in 25 ns. One model for beam loss predicts that a large charge, of the order of 10^6 MIPS, could be incident on the detector. According to detector studies, this causes a local field breakdown between the backplane of the sensor, held at 450V, and the strips. In this case the signal seen on the readout strip has a rise time of about 1μs due to a charge screening effect. A seco...

  14. ATLAS ABCD Hybrid Fatal Charge Dosage Test

    CERN Document Server

    Kuhl, A; Grillo, A A; Martinez-McKinney, F; Nielsen, J; Spencer, E; Wilder, M

    2011-01-01

    The Semi-Conductor Tracker (SCT) in the ATLAS experiment at the Large Hadron Collider (LHC) could be subject to various beam loss scenarios. If a severe beam loss event were to occur, it would be beneficial to know how SCT components would be affected. In the SCT detector modules, a key component is the ABCD application specific integrated circuit (ASIC), the onboard readout electronics of the system. This ASIC has design specifications that it should withstand a 5 nC charge application within 25 ns, which is the period of the LHC bunch crossing. The first test performed is designed to test this limit, reaching a maximum of 10 nC deposited in 25 ns. One model for beam loss predicts that a large charge, of the order of 106 MIPS, could be incident on the detector. According to detector studies, this causes a local field breakdown between the backplane of the sensor, held at 450 V, and the strips. In this case the signal seen on the readout strip has a rise time of about 1 μs due to a charge screening effect. A...

  15. Doubled dosage of sofosbuviris expected for inhibiting Zika virus infection

    Institute of Scientific and Technical Information of China (English)

    Somsri Wiwanitkit; Viroj Wiwanitkit

    2017-01-01

    Sofosbuvir is a new antiviral drug that has been recommended for management of hepatitis C virus (HCV) for a few years. New researches support that sofosbuvir might be useful for the management of Zika virus infection. Based on the pharmacological activity, inhibiting the HCV RNA-dependent RNA polymerase (RdRp or NS5 protein), sofosbuvir is proposed for its effectiveness against Zika virus infection. Here, the authors used a mathematical modelling theoretical approach to predict the expected dosage of sofosbuvir for inhibiting Zika virus infection. Based on the modeling study, if sofosbuvir is assigned for management of Zika virus infection, doubled dosage of the present dosage for hepatitis C management is recommended.

  16. Dosage of boron traces in graphite, uranium and beryllium oxide

    International Nuclear Information System (INIS)

    Coursier, J.; Hure, J.; Platzer, R.

    1955-01-01

    The problem of the dosage of the boron in the materials serving to the construction of nuclear reactors arises of the following way: to determine to about 0,1 ppm close to the quantities of boron of the order of tenth ppm. We have chosen the colorimetric analysis with curcumin as method of dosage. To reach the indicated contents, it is necessary to do a previous separation of the boron and the materials of basis, either by extraction of tetraphenylarsonium fluoborate in the case of the boron dosage in uranium and the beryllium oxide, either by the use of a cations exchanger resin of in the case of graphite. (M.B.) [fr

  17. Evolution of vertebrate sex chromosomes and dosage compensation.

    Science.gov (United States)

    Graves, Jennifer A Marshall

    2016-01-01

    Differentiated sex chromosomes in mammals and other vertebrates evolved independently but in strikingly similar ways. Vertebrates with differentiated sex chromosomes share the problems of the unequal expression of the genes borne on sex chromosomes, both between the sexes and with respect to autosomes. Dosage compensation of genes on sex chromosomes is surprisingly variable - and can even be absent - in different vertebrate groups. Systems that compensate for different gene dosages include a wide range of global, regional and gene-by-gene processes that differ in their extent and their molecular mechanisms. However, many elements of these control systems are similar across distant phylogenetic divisions and show parallels to other gene silencing systems. These dosage systems cannot be identical by descent but were probably constructed from elements of ancient silencing mechanisms that are ubiquitous among vertebrates and shared throughout eukaryotes.

  18. The Chernobyl Tissue Bank: integrating research on radiation-induced thyroid cancer.

    Science.gov (United States)

    Thomas, G A

    2012-03-01

    The only unequivocal radiological effect of the Chernobyl accident on human health is the increase in thyroid cancer in those exposed in childhood or early adolescence. Cancer is a complicated disease and it is unclear whether the mechanism by which radiation gives rise to cancer differs from that involved in the generation of cancers of the same type by other environmental stimuli. The Chernobyl Tissue Bank was established in response to the scientific interest in studying the molecular biology of thyroid cancer after Chernobyl to address this question. The project is supported by the governments of Ukraine and Russia, and financially supported (in total around US$3 million) by the European Commission, the National Cancer Institute of the USA and the Sasakawa Memorial Health Foundation of Japan. The project began collecting a variety of biological samples from patients on 1 October 1988, and has supplied material to 23 research projects in Japan, the USA and Europe. The establishment of the Chernobyl Tissue Bank has facilitated co-operation between these research projects and the combination of clinical and research data provides a paradigm for cancer research in the molecular biological age.

  19. Towards an integrative computational model for simulating tumor growth and response to radiation therapy

    Science.gov (United States)

    Marrero, Carlos Sosa; Aubert, Vivien; Ciferri, Nicolas; Hernández, Alfredo; de Crevoisier, Renaud; Acosta, Oscar

    2017-11-01

    Understanding the response to irradiation in cancer radiotherapy (RT) may help devising new strategies with improved tumor local control. Computational models may allow to unravel the underlying radiosensitive mechanisms intervening in the dose-response relationship. By using extensive simulations a wide range of parameters may be evaluated providing insights on tumor response thus generating useful data to plan modified treatments. We propose in this paper a computational model of tumor growth and radiation response which allows to simulate a whole RT protocol. Proliferation of tumor cells, cell life-cycle, oxygen diffusion, radiosensitivity, RT response and resorption of killed cells were implemented in a multiscale framework. The model was developed in C++, using the Multi-formalism Modeling and Simulation Library (M2SL). Radiosensitivity parameters extracted from literature enabled us to simulate in a regular grid (voxel-wise) a prostate cell tissue. Histopathological specimens with different aggressiveness levels extracted from patients after prostatectomy were used to initialize in silico simulations. Results on tumor growth exhibit a good agreement with data from in vitro studies. Moreover, standard fractionation of 2 Gy/fraction, with a total dose of 80 Gy as a real RT treatment was applied with varying radiosensitivity and oxygen diffusion parameters. As expected, the high influence of these parameters was observed by measuring the percentage of survival tumor cell after RT. This work paves the way to further models allowing to simulate increased doses in modified hypofractionated schemes and to develop new patient-specific combined therapies.

  20. The Chernobyl Tissue Bank: integrating research on radiation-induced thyroid cancer

    International Nuclear Information System (INIS)

    Thomas, G A

    2012-01-01

    The only unequivocal radiological effect of the Chernobyl accident on human health is the increase in thyroid cancer in those exposed in childhood or early adolescence. Cancer is a complicated disease and it is unclear whether the mechanism by which radiation gives rise to cancer differs from that involved in the generation of cancers of the same type by other environmental stimuli. The Chernobyl Tissue Bank was established in response to the scientific interest in studying the molecular biology of thyroid cancer after Chernobyl to address this question. The project is supported by the governments of Ukraine and Russia, and financially supported (in total around US$3 million) by the European Commission, the National Cancer Institute of the USA and the Sasakawa Memorial Health Foundation of Japan. The project began collecting a variety of biological samples from patients on 1 October 1988, and has supplied material to 23 research projects in Japan, the USA and Europe. The establishment of the Chernobyl Tissue Bank has facilitated co-operation between these research projects and the combination of clinical and research data provides a paradigm for cancer research in the molecular biological age. (note)

  1. Oral pilocarpine for radiation-induced xerostomia: integrated efficacy and safety results from two prospective randomized clinical trials

    International Nuclear Information System (INIS)

    Rieke, John W.; Hafermann, Mark D.; Johnson, Jonas T.; LeVeque, Francis G.; Iwamoto, Ryan; Steiger, Barry W.; Muscoplat, Charles; Gallagher, Susan C.

    1995-01-01

    Purpose: Pilocarpine hydrochloride administered in either a fixed-dose or in a dose-titration protocol three times a day for 12 weeks was evaluated for its ability to relieve symptoms of postradiation xerostomia and to improve saliva production. The studies were randomized, double-blind, placebo-controlled, multicenter clinical trials. A total of 369 patients who had received at least 40 Gy of radiation to the head and neck with clinically significant xerostomia were enrolled in the two studies. In the dose-titration study, 162 patients were enrolled and they received a thrice daily regimen of 2.5 mg tablets for first 4 weeks, 5.0 mg tablets for the second 4 weeks, and 10.0 mg tablets for last 4 weeks of a 12-week study. Patients in the titration study were allowed to down titrate following at least one dose escalation to alleviate bothersome side effects, if any. In the fixed dose study, 207 patients received either placebo, 5.0 mg, or 10.0 mg tablets t.i.d. for 12 weeks. Methods and Materials: Patients were evaluated for symptomatic relief by responding to questionnaires using visual analog scales and categorical questions; and, for saliva production by sialometry. Questionnaires measured relief of intraoral dryness, improvement in overall condition (global response), oral discomfort, difficulty in speaking, chewing and swallowing, denture wearing, and usage of artificial saliva. Evaluations were conducted at baseline, and weeks 4, 8, and 12. Results: There were statistically significant improvements in salivary flow in pilocarpine treatment groups vs. placebo. There was a significant improvement in the overall 'global' condition of xerostomia associated with the use of pilocarpine in both studies. In the fixed-dose study, there were significant improvements in oral dryness, mouth comfort, ability to speak, and reduction in the use of oral comfort agents. The dose-titration study showed improvements in dryness that approached significance (p = 0.057) and a

  2. Decision-making in environmental radiation protection: using the ERICA Integrated Approach

    International Nuclear Information System (INIS)

    Zinger, I.; Copplestone, D.; Howard, B.J.

    2008-01-01

    The ERICA Integrated Approach and its associated tool and databases provide a method by which the likely impact of radioactive discharges on the environment can be evaluated, see Fig. 1. The various factors, which should be taken into account when making decisions both during and after an assessment has been made, are discussed for each stage in the assessment process for a hypothetical case study. The assessment will demonstrate the issues associated with the decision-making process at Tiers 1 and 2 within the ERICA Tool and how they may vary. The case study, set in England, evaluates the environmental impact of radioactive substances released under authorisation in response primarily to conservation legislation, because of the need to demonstrate that no adverse impacts will occur on Natura 2000 sites as a result of the release of an authorised substance

  3. Evaluation of the effect of torsemide on warfarin dosage requirements.

    Science.gov (United States)

    Lai, Sophia; Momper, Jeremiah D; Yam, Felix K

    2017-08-01

    Background According to drug interaction databases, torsemide may potentiate the effects of warfarin. Evidence for this drug-drug interaction, however, is conflicting and the clinical significance is unknown. Objective The aim of this study is to evaluate the impact of torsemide initiation on warfarin dosage requirements. Setting This study was conducted at the Veterans Affairs Healthcare System in San Diego, California. Method A retrospective cohort study was conducted using Veterans Affairs data from patients who were converted from bumetanide to torsemide between March 2014 and July 2014. Patients were also prescribed and taking warfarin during the observation period. Warfarin dosage requirements were evaluated to determine if any changes occurred within the first 3 months of starting torsemide. Main outcome measure The primary outcome was the average weekly warfarin dose before and after torsemide initiation. Results Eighteen patients met study inclusion criteria. The weekly warfarin dose before and after initiation of torsemide was not significantly different (34 ± 15 and 34 ± 13 mg, p > 0.05). Of those eighteen patients, only two experienced elevations in INR that required a decrease in warfarin dosage after torsemide initiation. Between those two patients, dosage reductions ranged from 5.3 to 18%. Conclusion These results indicated that most patients did not require any warfarin dosage adjustments after torsemide was initiated. The potential for interaction, however, still exists. While empiric warfarin dosage adjustments are not recommended when initiating torsemide, increased monitoring is warranted to minimize the risk of adverse effects.

  4. Innovation technique of radiation for the treatment of 4-chlorphenol as a model of POPs in waste water

    International Nuclear Information System (INIS)

    Yao Side; Dou Daying; Fu Haiying; Liu Shiheng; Wang Shilong; Sun Xiaoyu

    2005-01-01

    The pollution becomes more serious with the development of economy in China especially for waste water, among which 80% comes from industries. The absence of fresh water has large limitation to the development of China now. Because it will bring the most harmful results to environment and health of people, the degradation of POPs is very important. Radiation is one of the effective methods for mineralization of POPs as most of their compounds are derivatives of phenyl ring. However, the costs of equipment and operation are too high to use for irradiation. It should be supposed that breakage of benzene ring of POPs at lower irradiated dosage (below 20 kGy) in developed radiation processing turns into organic acids and other compounds, which could be removed by micro-organisms easily. It means that after irradiation organic materials can be treated by the use of biological method. It is obvious that integration of different processing could both use the advantage of breaking phenyl ring under lower dosage and overcome the disadvantage of reducing the TOC at very high dosage by use of irradiation. In this paper, the radiolytical mechanism of 4-chlorphenol as a model of POPs has been studied by the use of pulse radiolysis and analysis of stable products irradiated in different conditions. It has been shown that 4-chlorphenol can be turned into organic acids effectively in basic aqueous solution saturated with oxygen under lower irradiated dosages

  5. Dosage-based parameters for characterization of puff dispersion results.

    Science.gov (United States)

    Berbekar, Eva; Harms, Frank; Leitl, Bernd

    2015-01-01

    A set of parameters is introduced to characterize the dispersion of puff releases based on the measured dosage. These parameters are the dosage, peak concentration, arrival time, peak time, leaving time, ascent time, descent time and duration. Dimensionless numbers for the scaling of the parameters are derived from dimensional analysis. The dimensionless numbers are tested and confirmed based on a statistically representative wind tunnel dataset. The measurements were carried out in a 1:300 scale model of the Central Business District in Oklahoma City. Additionally, the effect of the release duration on the puff parameters is investigated. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Impact of radiation embrittlement on integrity of pressure vessel supports for two PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Cheverton, R.D.; Pennell, W.E.; Robinson, G.C.; Nanstad, R.K.

    1989-01-01

    Recent data from the HFIR vessel surveillance program indicate a substantial radiation embrittlement rate effect at low irradiation temperatures (/approximately/120/degree/F) for A212-B, A350-LF3, A105-II, and corresponding welds. PWR vessel supports are fabricated of similar materials and are subjected to the same low temperatures and fast neutron fluxes (10/sup 8/ to 10/sup 9/ neutrons/cm/sup 2//center dot/s, E > 1.0 MeV) as those in the HFIR vessel. Thus, the embrittlement rate of these structures may be greater than previously anticipated. A study sponsored by the NRC is under way at ORNL to determine the impact of the rate effect on PWR vessel-support life expectancy. The scope includes the interpretation and application of the HFIR data, a survey of all light-water-reactor vessel support designs, and a structural and fracture-mechanics analysis of the supports for two specific PWR plants of particular interest with regard to a potential for support failure as a result of propagation of flaws. Calculations performed thus far indicate best-estimate critical flaw sizes, corresponding to 32 EFPY, of /approximately/0.2 in. for one plant and /approximately/0.4 in. for the other. These flaw sizes are small enough to be of concern. However, it appears that low-cycle fatigue is not a viable mechanism for creation of flaws of this size, and thus, presumably, such flaws would have to exist at the time of fabrication. 59 refs., 128 figs., 49 tabs.

  7. Changed of the working capacity of CMOS integrated circuits under ionizing radiations effect of low and high dose rate; Izmeneniya rabotosposobnosti KMOP integral`nykh mikroskhem pri vozdejstvii ioniziruyushchikh izluchenij s nizkoj i vysokoj intensivnost`yu

    Energy Technology Data Exchange (ETDEWEB)

    Bogatyrev, Yu V; Korshunov, F P

    1994-12-31

    Results of experimental investigations into the working capacity of different types of integrated CMOS circuits under effect of electron and gamma radiation are presented. Methods for evaluating IC CMOS under low irradiation intensity using the microcircuit testing under hugh intensity or at increased temperature with regard to the processes of parameter reconstruction after irradiation are proposed.

  8. Integrated effect of gamma radiation and biocontrol agent on quality parameters of apple fruit: An innovative commercial preservation method

    International Nuclear Information System (INIS)

    Ahari Mostafavi, Hossein; Mahyar Mirmajlessi, Seyed; Fathollahi, Hadi; Shahbazi, Samira; Mohammad Mirjalili, Seyed

    2013-01-01

    Effects of gamma irradiation and biocontrol agent (Pseudomonas fluorescens) on the physico-chemical parameters (including moisture, total soluble solids, antioxidant activity, phenolic content and firmness) of cv. Golden Delicious apples were investigated for their ability to avoid the post-harvest blue mold caused by Penicillium expansum during cold storage. Freshly harvested apples were inoculated with P. expansum. Treated fruits were irradiated at doses of 0, 200, 400, 600 and 800 Gy and then inoculated with P. fluorescens suspension. Samples were evaluated at 3 month intervals. The results demonstrated a clear link between antioxidant activity and phenolic content, so that dose range of 200–400 Gy significantly increased phenolic content and antioxidant activity. Effect of P. fluorescens was similar to irradiation at 200 and 400 Gy that could prevent lesion diameter in pathogen-treated apples. As dose and storage time increased firmness decreased but, combination of P. fluorescens as well as irradiation (at 200–400 Gy) could decrease softening apple fruits during storage. In all parameters, P. fluorescens (as biocontrol agent) inhibited P. expansum similar to irradiation at 200–400 Gy. So, integrated treatment of irradiation and biocontrol agent explored the potential dual benefit of low doses (200 and 400 Gy) as a suitable method to sustain physico-chemical quality and conclusively reduce apple fruits losses during post-harvest preservation. - Highlights: • A suitable method to reduce apple quality losses during 9 month storage period. • Effects of γ radiation in combination with biocontrol agent on physico-chemical parameters of the apple fruits during cold storage. • The potential dual benefit of low irradiation dose combined with biocontrol agent. • Radiation dose determination for Penicillium expansum (postharvest pathogen) control

  9. Trial manufacture of simple integrated tube-type pyranometer by phycoerythrin and measurements of transmittance of solar radiation in crop canopies

    International Nuclear Information System (INIS)

    Yamamoto, H.; Honjo, H.; Kamota, F.; Suzuki, Y.; Hayakawa, S.

    1998-01-01

    We tried to construct a simple integrated tube-type pyranometer using phycoerythrin from seaweed pigment. The maximum sensitive wavehand of phycoerythrin was 550 nm - 560 nm, and this waveband was in the photosynthetically active radiation range. The acrylic tubes (outside diameter, 22 mm, length, 100 cm) were spread with white paints except for a strip 15 mm in width, and phycoerythrin was put into the acrylic tube. In the results from the outdoor measurements, the tube-type pyranometer showed a positive correlation between the transmittance of phycoerythrin (%) and the measured accumulated solar radiation (MJ n(-2)), but the slope of the linear equation was different in summer and winter. In an artificial climate room, the relationship between the transmissions of phycoerythrin and the accumulated solar radiation could be approximated by a quadratic equation at every temperature. In the measurements made outdoors, the accumulated solar radiation could be estimated using the transmittance of phycoerythrin and the mean air temperature during measurements

  10. Integration of radiation protection in occupational health and safety managementsystems - legal requirements and practical realization at the example of the Fraunhofer occupational health and safety management system FRAM

    International Nuclear Information System (INIS)

    Lambotte, S.; Severitt, S.; Weber, U.

    2002-01-01

    The protection of the employees, the people and the environment for the effects of radiation is regulated by numerous laws and rules set by the government and the occupational accident insurances. Primarily these rules apply for the responsibles, normally the employer, as well as for the safety officers. Occupational safety management systems can support these people to carry out their tasks and responsibilities effectively. Also, a systematic handling of the organisation secures that the numerous duties of documentation, time-checking of the proof-lists and dates are respected. Further more, the legal certainty for the responsibles and safety officers will be raised and the occupational, environment, radiation and health protection will be promoted. At the example of the Fraunhofer occupational safety management system (FrAM) it is demonstrated, how radiation protection (ionizing radiation) can be integrated in a progressive intranet supported management system. (orig.)

  11. 76 FR 59023 - Oral Dosage Form New Animal Drugs; Tylosin

    Science.gov (United States)

    2011-09-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Tylosin AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  12. 77 FR 3927 - Oral Dosage Form New Animal Drugs; Deracoxib

    Science.gov (United States)

    2012-01-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Deracoxib AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  13. 76 FR 18648 - Oral Dosage Form New Animal Drugs; Robenacoxib

    Science.gov (United States)

    2011-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Robenacoxib AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  14. 76 FR 40808 - Oral Dosage Form New Animal Drugs; Amprolium

    Science.gov (United States)

    2011-07-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Amprolium AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  15. 77 FR 15960 - Oral Dosage Form New Animal Drugs; Pergolide

    Science.gov (United States)

    2012-03-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Pergolide AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  16. 75 FR 67031 - Oral Dosage Form New Animal Drugs; Domperidone

    Science.gov (United States)

    2010-11-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2010-N-0002] Oral Dosage Form New Animal Drugs; Domperidone AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  17. 76 FR 78149 - Oral Dosage Form New Animal Drugs; Estriol

    Science.gov (United States)

    2011-12-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 520 [Docket No. FDA-2011-N-0003] Oral Dosage Form New Animal Drugs; Estriol AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is amending the animal drug...

  18. Pharmaceutical development of an intravenous dosage form of diacetylmorphine hydrochloride

    NARCIS (Netherlands)

    Klous, Marjolein G.; Nuijen, Bastiaan; van den Brink, Wim; van Ree, Jan M.; Beijnen, Jos H.

    2004-01-01

    A solid dosage form for multiple use was developed for parenteral administration of diacetylmorphine in a clinical trial on co-prescription of heroin to heroin addicts. A 300-mg/mL diacetylmorphine hydrochloride solution was lyophilised as 10-mL aliquots in 30-mL glass vials, to be reconstituted to

  19. Effect of lead acetate administered orally at different dosage levels ...

    African Journals Online (AJOL)

    The project was conducted to evaluate the effect of lead administered as lead acetate at different dosage levels via drinking water in broiler chicks. Thirty-five healthy chicks were divided into seven groups (five chicks each) and one group was kept as un-medicated control. Groups A, B, C, D, E and F were medicated with ...

  20. Quality of 'Climax' blueberries after low dosage electron beam irradiation

    International Nuclear Information System (INIS)

    Miller, W.R.; McDonald, R.E.; McCollum, T.G.; Smittle, B.J.

    1994-01-01

    Fruit of 'Climax' rabbiteye blueberries (Vaccinium ashei Reade) were irradiated by a linear accelerator at 0, 0.25, 0.5, 0.75, 1.0, and 1.25 kGy and evaluated for various quality attributes after storage for 1, 3, 7, or 14 days at 1C plus 2 days at 15C, respectively. Weight loss increased during storage and averaged 4.2% after the final inspection and was not affected by irradiation dosage. About 5% of total berries were decayed after 14 days at 1C, about 6% after the final inspection at 15C, but decay was not affected by the level of irradiation. Electrolyte leakage, skin color, total soluble solids, acidity, and pH were also not affected by irradiation dosage. There was a significant decline in berry firmness, flavor, and texture as dosage increased. Berries treated at 1.0 kGy or above were softer and had lower flavor and texture preference scores than berries treated at lower dosages or nontreated berries

  1. Dosage plasmatique et globulaire du magnesium dans l'exploration ...

    African Journals Online (AJOL)

    Objectives: The allergic rhinitis represents a real public health problem. The goal of this survey is to value the interest of the dosage plasmatical and globular of magnesium in the diagnosis of the allergic rhinitis. Materials and methods : Analytic and prospective survey of 80 files, on one period of 4 years and 5 months (from ...

  2. Determination of methadone hydrochloride in a maintenance dosage formulation.

    Science.gov (United States)

    Hoffmann, T J; Thompson, R D

    1975-07-01

    A colorimetric method for direct quantitative assay of methadone hydrochloride in liquid oral dosage forms is presented. The procedure involves the formation of a dye complex with bromothymol blue buffer solution. The resultant complex is extracted with benzene and measured spectrophotometrically. Duplicate tests on the formulation showed 99.2% of the labeled amount of methadone.

  3. 21 CFR 520.1448 - Monensin oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Monensin oral dosage forms. 520.1448 Section 520.1448 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... distance the spots travel from the starting line divided by the distance the solvent front travels from the...

  4. Dosage Compensation of an Aneuploid Genome in Mouse Spermatogenic Cells

    Czech Academy of Sciences Publication Activity Database

    Jansa, Petr; Homolka, David; Blatný, Radek; Mistrik, M.; Bartek, Jiří; Forejt, Jiří

    2014-01-01

    Roč. 90, č. 6 (2014), 124/1-124/9 ISSN 0006-3363 R&D Projects: GA ČR GA13-08078S Institutional support: RVO:68378050 Keywords : gene dosage * male sterility * segmental trisomy * meiotic silencing of unsynapsed chromatin * DOWN-SYNDROME * MAMMALIAN MEIOSIS Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.318, year: 2014

  5. Fuzzy-based dosage model of aqueous decoction of Adansonia ...

    African Journals Online (AJOL)

    However, in the area of traditional medicine, no much attention has been given to its enhancement with the use of information technology especially in the area of herbal prescription. ... The mass of herb and volume of solvent were used as input parameters to design the dosage model, and simulated using MATLAB.

  6. Formulation of Croton penduliflorus seed into tablet dosage form ...

    African Journals Online (AJOL)

    Formulation of Croton penduliflorus seed into tablet dosage form. GC Onunkwo. Abstract. No Abstract. Global Journal of Medical Sciences Vol. 5(1) 2006: 29-33. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/gjms.v5i1.10145.

  7. Formulation and evaluation of tablet dosage form of Hunteria ...

    African Journals Online (AJOL)

    The present study was aimed at formulating and evaluating tablet dosage form of Hunteria umbellata (HU) seed aqueous and purified extracts. HU seeds were dried, pulverized and the powder macerated in water to obtain aqueous extract, while alkaloidal extraction process was used to obtain purified extract. Extracts ...

  8. Biowaiver monographs for immediate release solid oral dosage forms: cimetidine.

    NARCIS (Netherlands)

    Jantratid, E; Prakongpan, S; Dressman, J B; Amidon, G L; Junginger, H E; Midha, K K; Barends, D M

    2006-01-01

    Literature data relevant to the decision to allow a waiver of in vivo bioequivalence (BE) testing for the approval of immediate release (IR) solid oral dosage forms containing cimetidine are reviewed. According to the current Biopharmaceutics Classification System (BCS), cimetidine would be assigned

  9. Dosage Compensation of an Aneuploid Genome in Mouse Spermatogenic Cells

    Czech Academy of Sciences Publication Activity Database

    Jansa, Petr; Homolka, David; Blatný, Radek; Mistrik, M.; Bartek, Jiří; Forejt, Jiří

    2014-01-01

    Roč. 90, č. 6 (2014), 124/1-124/9 ISSN 0006-3363 R&D Projects: GA ČR GA13-08078S Institutional support: RVO:68378050 Keywords : gene dosage * male sterility * segmental trisomy * meiotic silencing of unsynapsed chromatin * DOWN - SYNDROME * MAMMALIAN MEIOSIS Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.318, year: 2014

  10. X chromosome dosage compensation via enhanced transcriptional elongation in Drosophila.

    Science.gov (United States)

    Larschan, Erica; Bishop, Eric P; Kharchenko, Peter V; Core, Leighton J; Lis, John T; Park, Peter J; Kuroda, Mitzi I

    2011-03-03

    The evolution of sex chromosomes has resulted in numerous species in which females inherit two X chromosomes but males have a single X, thus requiring dosage compensation. MSL (Male-specific lethal) complex increases transcription on the single X chromosome of Drosophila males to equalize expression of X-linked genes between the sexes. The biochemical mechanisms used for dosage compensation must function over a wide dynamic range of transcription levels and differential expression patterns. It has been proposed that the MSL complex regulates transcriptional elongation to control dosage compensation, a model subsequently supported by mapping of the MSL complex and MSL-dependent histone 4 lysine 16 acetylation to the bodies of X-linked genes in males, with a bias towards 3' ends. However, experimental analysis of MSL function at the mechanistic level has been challenging owing to the small magnitude of the chromosome-wide effect and the lack of an in vitro system for biochemical analysis. Here we use global run-on sequencing (GRO-seq) to examine the specific effect of the MSL complex on RNA Polymerase II (RNAP II) on a genome-wide level. Results indicate that the MSL complex enhances transcription by facilitating the progression of RNAP II across the bodies of active X-linked genes. Improving transcriptional output downstream of typical gene-specific controls may explain how dosage compensation can be imposed on the diverse set of genes along an entire chromosome.

  11. Dosage compensation and demasculinization of X chromosomes in Drosophila.

    Science.gov (United States)

    Bachtrog, Doris; Toda, Nicholas R T; Lockton, Steven

    2010-08-24

    The X chromosome of Drosophila shows a deficiency of genes with male-biased expression, whereas mammalian X chromosomes are enriched for spermatogenesis genes expressed premeiosis and multicopy testis genes. Meiotic X-inactivation and sexual antagonism can only partly account for these patterns. Here, we show that dosage compensation (DC) in Drosophila may contribute substantially to the depletion of male genes on the X. To equalize expression between X-linked and autosomal genes in the two sexes, male Drosophila hypertranscribe their single X, whereas female mammals silence one of their two X chromosomes. We combine fine-scale mapping data of dosage compensated regions with genome-wide expression profiles and show that most male-biased genes on the D. melanogaster X are located outside dosage compensated regions. Additionally, X-linked genes that have newly acquired male-biased expression in D. melanogaster are less likely to be dosage compensated, and parental X-linked genes that gave rise to an autosomal male-biased retrocopy are more likely located within compensated regions. This suggests that DC contributes to the observed demasculinization of X chromosomes in Drosophila, both by limiting the emergence of male-biased expression patterns of existing X genes, and by contributing to gene trafficking of male genes off the X. Copyright 2010 Elsevier Ltd. All rights reserved.

  12. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    African Journals Online (AJOL)

    Purpose: To develop simple, rapid and selective spectrophotometric methods for the determination of cilostazol in tablet dosage form. Methods: Cilostazol was dissolved in 50 % methanol and its absorbance was scanned by ultraviolet (UV) spectrophotometry. Both linear regression equation and standard absorptivity were ...

  13. The presence of mathematics and computer anxiety in nursing students and their effects on medication dosage calculations.

    Science.gov (United States)

    Glaister, Karen

    2007-05-01

    To determine if the presence of mathematical and computer anxiety in nursing students affects learning of dosage calculations. The quasi-experimental study compared learning outcomes at differing levels of mathematical and computer anxiety when integrative and computer based learning approaches were used. Participants involved a cohort of second year nursing students (n=97). Mathematical anxiety exists in 20% (n=19) of the student nurse population, and 14% (n=13) experienced mathematical testing anxiety. Those students more anxious about mathematics and the testing of mathematics benefited from integrative learning to develop conditional knowledge (F(4,66)=2.52 at pComputer anxiety was present in 12% (n=11) of participants, with those reporting medium and high levels of computer anxiety performing less well than those with low levels (F(1,81)=3.98 at pmathematical and computer anxiety when planning an educational program to develop competency in dosage calculations.

  14. Maths anxiety and medication dosage calculation errors: A scoping review.

    Science.gov (United States)

    Williams, Brett; Davis, Samantha

    2016-09-01

    A student's accuracy on drug calculation tests may be influenced by maths anxiety, which can impede one's ability to understand and complete mathematic problems. It is important for healthcare students to overcome this barrier when calculating drug dosages in order to avoid administering the incorrect dose to a patient when in the clinical setting. The aim of this study was to examine the effects of maths anxiety on healthcare students' ability to accurately calculate drug dosages by performing a scoping review of the existing literature. This review utilised a six-stage methodology using the following databases; CINAHL, Embase, Medline, Scopus, PsycINFO, Google Scholar, Trip database (http://www.tripdatabase.com/) and Grey Literature report (http://www.greylit.org/). After an initial title/abstract review of relevant papers, and then full text review of the remaining papers, six articles were selected for inclusion in this study. Of the six articles included, there were three experimental studies, two quantitative studies and one mixed method study. All studies addressed nursing students and the presence of maths anxiety. No relevant studies from other disciplines were identified in the existing literature. Three studies took place in the U.S, the remainder in Canada, Australia and United Kingdom. Upon analysis of these studies, four factors including maths anxiety were identified as having an influence on a student's drug dosage calculation abilities. Ultimately, the results from this review suggest more research is required in nursing and other relevant healthcare disciplines regarding the effects of maths anxiety on drug dosage calculations. This additional knowledge will be important to further inform development of strategies to decrease the potentially serious effects of errors in drug dosage calculation to patient safety. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. 'Integration'

    DEFF Research Database (Denmark)

    Olwig, Karen Fog

    2011-01-01

    , while the countries have adopted disparate policies and ideologies, differences in the actual treatment and attitudes towards immigrants and refugees in everyday life are less clear, due to parallel integration programmes based on strong similarities in the welfare systems and in cultural notions...... of equality in the three societies. Finally, it shows that family relations play a central role in immigrants’ and refugees’ establishment of a new life in the receiving societies, even though the welfare society takes on many of the social and economic functions of the family....

  16. SU-G-TeP4-06: An Integrated Application for Radiation Therapy Treatment Plan Directives, Management, and Reporting

    Energy Technology Data Exchange (ETDEWEB)

    Matuszak, M; Anderson, C; Lee, C; Vineberg, K; Green, M; Younge, K; Moran, J; Mayo, C [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: With electronic medical records, patient information for the treatment planning process has become disseminated across multiple applications with limited quality control and many associated failure modes. We present the development of a single application with a centralized database to manage the planning process. Methods: The system was designed to replace current functionalities of (i) static directives representing the physician intent for the prescription and planning goals, localization information for delivery, and other information, (ii) planning objective reports, (iii) localization and image guidance documents and (iv) the official radiation therapy prescription in the medical record. Using the Eclipse Scripting Application Programming Interface, a plug-in script with an associated domain-specific SQL Server database was created to manage the information in (i)–(iv). The system’s user interface and database were designed by a team of physicians, clinical physicists, database experts, and software engineers to ensure usability and robustness for clinical use. Results: The resulting system has been fully integrated within the TPS via a custom script and database. Planning scenario templates, version control, approvals, and logic-based quality control allow this system to fully track and document the planning process as well as physician approval of tradeoffs while improving the consistency of the data. Multiple plans and prescriptions are supported along with non-traditional dose objectives and evaluation such as biologically corrected models, composite dose limits, and management of localization goals. User-specific custom views were developed for the attending physician review, physicist plan checks, treating therapists, and peer review in chart rounds. Conclusion: A method was developed to maintain cohesive information throughout the planning process within one integrated system by using a custom treatment planning management application that

  17. An integrated campaign for investigation of winter-time continental haze over Indo-Gangetic Basin and its radiative effects

    International Nuclear Information System (INIS)

    Das, Sanat Kumar; Chatterjee, Abhijit; Ghosh, Sanjay K.; Raha, Sibaji

    2015-01-01

    An outflow of continental haze occurs from Indo-Gangetic Basin (IGB) in the North to Bay of Bengal (BoB) in the South. An integrated campaign was organized to investigate this continental haze during December 2013–February 2014 at source and remote regions within IGB to quantify its radiative effects. Measurements were carried out at three locations in eastern India; 1) Kalas Island, Sundarban (21.68°N, 88.57°E) — an isolated island along the north-east coast of BoB, 2) Kolkata (22.57°N, 88.42°E) — an urban metropolis and 3) Siliguri (26.70°N, 88.35°E) — an urban region at the foothills of eastern Himalayas. Ground-based AOD (at 0.5 μm) is observed to be maximum (1.25 ± 0.18) over Kolkata followed by Siliguri (0.60 ± 0.17) and minimum over Sundarban (0.53 ± 0.18). Black carbon concentration is found to be maximum at Kolkata (21.6 ± 6.6 μg·m −3 ) with almost equal concentrations at Siliguri (12.6 ± 5.2 μg·m −3 ) and Sundarban (12.3 ± 3.0 μg·m −3 ). Combination of MODIS-AOD and back-trajectories analysis shows an outflow of winter-time continental haze originating from central IGB and venting out through Sundarban towards BoB. This continental haze with high extinction coefficient is identified up to central BoB using CALIPSO observations and is found to contribute ~ 75% to marine AOD over central BoB. This haze produces significantly high aerosol radiative forcing within the atmosphere over Kolkata (75.4 Wm −2 ) as well as over Siliguri and Sundarban (40 Wm −2 ) indicating large forcing over entire IGB, from foothills of the Himalayas to coastal region. This winter-time continental haze also causes about similar radiative heating (1.5 K·day −1 ) from Siliguri to Sundarban which is enhanced over Kolkata (3 K·day −1 ) due to large emission of local urban aerosols. This high aerosol heating over entire IGB and coastal region of BoB can have considerable impact on the monsoonal circulation and more importantly, such haze

  18. An integrated campaign for investigation of winter-time continental haze over Indo-Gangetic Basin and its radiative effects

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sanat Kumar, E-mail: sanatkrdas@gmail.com [Environmental Sciences Section, Bose Institute, Kolkata (India); Center for Astroparticle Physics and Space Science, Bose Institute, Kolkata (India); Chatterjee, Abhijit [Environmental Sciences Section, Bose Institute, Kolkata (India); Center for Astroparticle Physics and Space Science, Bose Institute, Kolkata (India); National Facility on Astroparticle Physics and Space Science, Darjeeling (India); Ghosh, Sanjay K. [Center for Astroparticle Physics and Space Science, Bose Institute, Kolkata (India); National Facility on Astroparticle Physics and Space Science, Darjeeling (India); Raha, Sibaji [Environmental Sciences Section, Bose Institute, Kolkata (India); Center for Astroparticle Physics and Space Science, Bose Institute, Kolkata (India); National Facility on Astroparticle Physics and Space Science, Darjeeling (India)

    2015-11-15

    An outflow of continental haze occurs from Indo-Gangetic Basin (IGB) in the North to Bay of Bengal (BoB) in the South. An integrated campaign was organized to investigate this continental haze during December 2013–February 2014 at source and remote regions within IGB to quantify its radiative effects. Measurements were carried out at three locations in eastern India; 1) Kalas Island, Sundarban (21.68°N, 88.57°E) — an isolated island along the north-east coast of BoB, 2) Kolkata (22.57°N, 88.42°E) — an urban metropolis and 3) Siliguri (26.70°N, 88.35°E) — an urban region at the foothills of eastern Himalayas. Ground-based AOD (at 0.5 μm) is observed to be maximum (1.25 ± 0.18) over Kolkata followed by Siliguri (0.60 ± 0.17) and minimum over Sundarban (0.53 ± 0.18). Black carbon concentration is found to be maximum at Kolkata (21.6 ± 6.6 μg·m{sup −3}) with almost equal concentrations at Siliguri (12.6 ± 5.2 μg·m{sup −3}) and Sundarban (12.3 ± 3.0 μg·m{sup −3}). Combination of MODIS-AOD and back-trajectories analysis shows an outflow of winter-time continental haze originating from central IGB and venting out through Sundarban towards BoB. This continental haze with high extinction coefficient is identified up to central BoB using CALIPSO observations and is found to contribute ~ 75% to marine AOD over central BoB. This haze produces significantly high aerosol radiative forcing within the atmosphere over Kolkata (75.4 Wm{sup −2}) as well as over Siliguri and Sundarban (40 Wm{sup −2}) indicating large forcing over entire IGB, from foothills of the Himalayas to coastal region. This winter-time continental haze also causes about similar radiative heating (1.5 K·day{sup −1}) from Siliguri to Sundarban which is enhanced over Kolkata (3 K·day{sup −1}) due to large emission of local urban aerosols. This high aerosol heating over entire IGB and coastal region of BoB can have considerable impact on the monsoonal circulation and more

  19. Simultaneous integrated protection. A new concept for high-precision radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Thomas B.; Nestle, Ursula; Adebahr, Sonja; Gkika, Eleni; Wiehle, Rolf; Baltas, Dimos; Grosu, Anca-Ligia [University Hospitals Freiburg, Department of Radiation Oncology, Freiburg (Germany); German Cancer Consortium (DKTK), Partner Site Freiburg, Heidelberg (Germany)

    2016-12-15

    Stereotactic radiotherapy near serial organs at risk (OAR) requires special caution. A novel intensity-modulated radiotherapy (IMRT) prescription concept termed simultaneous integrated protection (SIP) for quantifiable and comparable dose prescription to targets very close to OAR is described. An intersection volume of a planning risk volume (PRV) with the total planning target volume (PTV) defined the protection volume (PTV{sub SIP}). The remainder of the PTV represented the dominant PTV (PTV{sub dom}). Planning was performed using IMRT. Dose was prescribed to PTV{sub dom} according to ICRU in 3, 5, 8, or 12 fractions. Constraints to OARs were expressed as absolute and as equieffective doses at 2 Gy (EQD2). Dose to the gross risk volume of an OAR was to respect constraints. Violation of constraints to OAR triggered a planning iteration at increased fractionation. Dose to PTV{sub SIP} was required to be as high as possible within the constraints to avoid local relapse. SIP was applied in 6 patients with OAR being large airways (n = 2) or bowel (n = 4) in 3, 5, 8, and 12 fractions in 1, 3, 1, and 1 patients, respectively. PTVs were 14.5-84.9 ml and PTV{sub SIP} 1.8-3.9 ml (2.9-13.4 % of PTV). Safety of the plans was analyzed from the absolute dose-volume histogram (dose to ml). The steepness of dose fall-off could be determined by comparing the dose constraints to the PRVs with those to the OARs (Wilcoxon test p = 0.001). Constraints were respected for the corresponding OARs. All patients had local control at a median 9 month follow-up and toxicity was low. SIP results in a median dose of ≥100 % to PTV, to achieve high local control and low toxicity. Longer follow-up is required to verify results and a prospective clinical trial is currently testing this new approach in chest and abdomen stereotactic body radiotherapy. (orig.) [German] Die stereotaktische Radiotherapie nahe serieller Risikoorgane (OAR) erfordert besondere Vorsicht. Wir beschreiben ein neues

  20. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

    International Nuclear Information System (INIS)

    Lin, Pei-Jan P.; Schueler, Beth A.; Balter, Stephen; Strauss, Keith J.; Wunderle, Kevin A.; LaFrance, M. Terry; Kim, Don-Soo; Behrman, Richard H.; Shepard, S. Jeff; Bercha, Ishtiaq H.

    2015-01-01

    Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field

  1. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan P., E-mail: Pei-Jan.Lin@vcuhealth.org [Virginia Commonwealth University Medical Center, Richmond, Virginia 23298 (United States); Schueler, Beth A. [Mayo Clinic, Rochester, Minnesota 55905 (United States); Balter, Stephen [Columbia University Medical Center, New York, New York 10032 (United States); Strauss, Keith J. [Children’s Hospital Medical Center, Cincinnati, Ohio 45229 (United States); Wunderle, Kevin A. [Cleveland Clinic Foundation, Cleveland, Ohio 44195 (United States); LaFrance, M. Terry [Baystate Health Systems, Inc., Springfield, Massachusetts 01199 (United States); Kim, Don-Soo [Children’s Hospital Boston, Boston, Massachusetts 02115 (United States); Behrman, Richard H. [Boston University Medical Center, Boston, Massachusetts 02118 (United States); Shepard, S. Jeff [University of Texas MD Anderson Cancer Center, Houston, Texas 77096 (United States); Bercha, Ishtiaq H. [Children’s Hospital Colorado, Aurora, Colorado 80045 (United States)

    2015-12-15

    Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

  2. Amylase and blood cell-count hematological radiation-injury biomarkers in a rhesus monkey radiation model-use of multiparameter and integrated biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, W.F. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: blakely@afrri.usuhs.mil; Ossetrova, N.I.; Manglapus, G.L.; Salter, C.A.; Levine, I.H.; Jackson, W.E.; Grace, M.B.; Prasanna, P.G.S.; Sandgren, D.J.; Ledney, G.D. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2007-07-15

    Effective medical management of suspected radiation exposure incidents requires the recording of dynamic medical data (clinical signs and symptoms), biological assessments of radiation exposure, and physical dosimetry in order to provide diagnostic information to the treating physician and dose assessment for personnel radiation protection records. The need to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios prompted an evaluation of suitable biomarkers that can provide early diagnostic information after exposure. We investigated the utility of serum amylase and hematological blood-cell count biomarkers to provide early assessment of severe radiation exposures in a non-human primate model (i.e., rhesus macaques; n=8) exposed to whole-body radiation of {sup 60}Co-gamma rays (6.5 Gy, 40cGymin{sup -1}). Serum amylase activity was significantly elevated (12.3{+-}3.27- and 2.6{+-}0.058-fold of day zero samples) at 1 and 2-days, respectively, after radiation. Lymphocyte cell counts decreased ({<=}15% of day zero samples) 1 and 2 days after radiation exposure. Neutrophil cell counts increased at day one by 1.9({+-}0.38)-fold compared with levels before irradiation. The ratios of neutrophil to lymphocyte cell counts increased by 13({+-}2.66)- and 4.23({+-}0.95)-fold at 1 and 2 days, respectively, after irradiation. These results demonstrate that increases in serum amylase activity along with decreases of lymphocyte counts, increases in neutrophil cell counts, and increases in the ratio of neutrophil to lymphocyte counts 1 day after irradiation can provide enhanced early triage discrimination of individuals with severe radiation exposure and injury. Use of the biodosimetry assessment tool (BAT) application is encouraged to permit dynamic recording of medical data in the management of a suspected radiological casualty.

  3. Effect of 18F-FDG dosage alternation on final PET image

    International Nuclear Information System (INIS)

    Yin Dayi; Yao Shulin; Chen Yingmao; Shao Mingzhe; Tian Jiahe

    2002-01-01

    Objective: To assess PET reconstructed image effected by different 18 F-FDG dosages with quantitative and qualitative analysis. Methods: To perform PET phantom acquisition by routine clinical parameters after filled with different doses of 18 F-FDG solution. An identical slice was extracted from reconstructed image for doing following analysis: the hot area standard uptake value (SUV), the ratio of hot area to cold area, the standard deviation on background area, the ratio of true coincidence to random. Results: 296 MBq: The image uniformity was terribly worse, T/R=0.83, other indexes were irregular. 148 MBq: The image presentation looked like the image without attenuation correction, T/R=1.64, other indexes were moderate. 74, 37 and 18.5 MBq: The images were with excellent uniformity, resolution and contrast, the background noise was suitable, all of the quantitative indexes were good. 9.25 and 4.625 MBq: The uniformity and resolution was degraded terribly because of the higher noise and lower information. Conclusion: Combining above results with other considerations, such as radiation exposure, information amount and acquisition time, the authors think the optimal dosage should be 4.625-11.1 MBq/kg

  4. Radiologic observations on pulmonary radiation injury

    International Nuclear Information System (INIS)

    Liang Yong

    1992-01-01

    Based on the data of pulmonary radiation injury in 16 cases, the relationship among the radiation dosage and field, the development and onset time of the pulmonary radiation injury were discussed, and the dynamic changes of pulmonary radiation injury in X-ray films were analysed. The author found that: (1) there was a close relationship between the development of radiation injury and radiation dosages and the size of radiation fields, i.e. for the large radiation field, a relatively small dosage was needed for developing radiation injury ; (2) most off acute radiation injury of the lungs appeared within one month of postirradiation therapy, and the chronic pulmonary fibrosis appeared at 4.23 months after radiation therapy, with a fibrosis rate of about 85.7% within a half year; (3) the clinical manifestations of pulmonary radiation injury were not parallel to the X-ray signs, namely the X-ray changes were more severe than clinical manifestations. On the basis of X-ray signs and the dynamic changes of pulmonary radiation injury, the differentiation of radiation injury from interstitial pulmonary metastasis, primary tumor, common pneumonia, and tumor recurrence after radiation therapy were discussed

  5. Assessment of radiation damage - the need for a multi-parametric and integrative approach with the help of both clinical and biological dosimetry

    International Nuclear Information System (INIS)

    Meineke, Viktor

    2008-01-01

    provide the best basis for triage and planning and providing of medical treatment after accidental radiation exposure always different and independent diagnostic procedures integrating all clinical aspects as well as different biological indicators have to be applied. Up to now this multi parametric approach is missing in medical radiation accident management. A new integrative concept is shown and discussed. (author)

  6. Gene dosage, expression, and ontology analysis identifies driver genes in the carcinogenesis and chemoradioresistance of cervical cancer.

    Directory of Open Access Journals (Sweden)

    Malin Lando

    2009-11-01

    Full Text Available Integrative analysis of gene dosage, expression, and ontology (GO data was performed to discover driver genes in the carcinogenesis and chemoradioresistance of cervical cancers. Gene dosage and expression profiles of 102 locally advanced cervical cancers were generated by microarray techniques. Fifty-two of these patients were also analyzed with the Illumina expression method to confirm the gene expression results. An independent cohort of 41 patients was used for validation of gene expressions associated with clinical outcome. Statistical analysis identified 29 recurrent gains and losses and 3 losses (on 3p, 13q, 21q associated with poor outcome after chemoradiotherapy. The intratumor heterogeneity, assessed from the gene dosage profiles, was low for these alterations, showing that they had emerged prior to many other alterations and probably were early events in carcinogenesis. Integration of the alterations with gene expression and GO data identified genes that were regulated by the alterations and revealed five biological processes that were significantly overrepresented among the affected genes: apoptosis, metabolism, macromolecule localization, translation, and transcription. Four genes on 3p (RYBP, GBE1 and 13q (FAM48A, MED4 correlated with outcome at both the gene dosage and expression level and were satisfactorily validated in the independent cohort. These integrated analyses yielded 57 candidate drivers of 24 genetic events, including novel loci responsible for chemoradioresistance. Further mapping of the connections among genetic events, drivers, and biological processes suggested that each individual event stimulates specific processes in carcinogenesis through the coordinated control of multiple genes. The present results may provide novel therapeutic opportunities of both early and advanced stage cervical cancers.

  7. Genetic basis for dosage sensitivity in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Isabelle M Henry

    2007-04-01

    Full Text Available Aneuploidy, the relative excess or deficiency of specific chromosome types, results in gene dosage imbalance. Plants can produce viable and fertile aneuploid individuals, while most animal aneuploids are inviable or developmentally abnormal. The swarms of aneuploid progeny produced by Arabidopsis triploids constitute an excellent model to investigate the mechanisms governing dosage sensitivity and aneuploid syndromes. Indeed, genotype alters the frequency of aneuploid types within these swarms. Recombinant inbred lines that were derived from a triploid hybrid segregated into diploid and tetraploid individuals. In these recombinant inbred lines, a single locus, which we call SENSITIVE TO DOSAGE IMBALANCE (SDI, exhibited segregation distortion in the tetraploid subpopulation only. Recent progress in quantitative genotyping now allows molecular karyotyping and genetic analysis of aneuploid populations. In this study, we investigated the causes of the ploidy-specific distortion at SDI. Allele frequency was distorted in the aneuploid swarms produced by the triploid hybrid. We developed a simple quantitative measure for aneuploidy lethality and using this measure demonstrated that distortion was greatest in the aneuploids facing the strongest viability selection. When triploids were crossed to euploids, the progeny, which lack severe aneuploids, exhibited no distortion at SDI. Genetic characterization of SDI in the aneuploid swarm identified a mechanism governing aneuploid survival, perhaps by buffering the effects of dosage imbalance. As such, SDI could increase the likelihood of retaining genomic rearrangements such as segmental duplications. Additionally, in species where triploids are fertile, aneuploid survival would facilitate gene flow between diploid and tetraploid populations via a triploid bridge and prevent polyploid speciation. Our results demonstrate that positional cloning of loci affecting traits in populations containing ploidy and

  8. Non-Conventional Applications of Computerized Tomography: Analysis of Solid Dosage Forms Produced by Pharmaceutical Industry

    International Nuclear Information System (INIS)

    Martins de Oliveira, Jose Jr.; Germano Martins, Antonio Cesar

    2010-01-01

    X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.

  9. Beneficial and adverse effects of irradiation in patients repeatedly subjected to high-dosage treatment

    International Nuclear Information System (INIS)

    Roeckelein, I.

    1986-01-01

    During the period between 1978 and 1983 a total of 156 patients showing different types of tumours were subjected to high-dosage radiotherapy. The patients were treated repeatedly for primary or recurrent tumours using a radiation dose of >79 Gy. Each of the three largest groups, which were mammary carcinomas (33), cerebral tumours (25) and orohypopharyngeal tumours (22), was analysed individually. In the majority of patients the local effects of this radiotherapy were such that total or at least partial remission of the primary or recurrent tumour appeared most likely. In the groups receiving doses in the lower range the results were just as good as those achieved in subjects exposed to high doses. The survival times determined here for bearers of mammary or cerebral carcinomas were better than the relevant values given in the literature. (orig./MG) [de

  10. QR encoded smart oral dosage forms by inkjet printing.

    Science.gov (United States)

    Edinger, Magnus; Bar-Shalom, Daniel; Sandler, Niklas; Rantanen, Jukka; Genina, Natalja

    2018-01-30

    The use of inkjet printing (IJP) technology enables the flexible manufacturing of personalized medicine with the doses tailored for each patient. In this study we demonstrate, for the first time, the applicability of IJP in the production of edible dosage forms in the pattern of a quick response (QR) code. This printed pattern contains the drug itself and encoded information relevant to the patient and/or healthcare professionals. IJP of the active pharmaceutical ingredient (API)-containing ink in the pattern of QR code was performed onto a newly developed porous and flexible, but mechanically stable substrate with a good absorption capacity. The printing did not affect the mechanical properties of the substrate. The actual drug content of the printed dosage forms was in accordance with the encoded drug content. The QR encoded dosage forms had a good print definition without significant edge bleeding. They were readable by a smartphone even after storage in harsh conditions. This approach of efficient data incorporation and data storage combined with the use of smart devices can lead to safer and more patient-friendly drug products in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Prevalence and trends of cellulosics in pharmaceutical dosage forms.

    Science.gov (United States)

    Mastropietro, David J; Omidian, Hossein

    2013-02-01

    Many studies have shown that cellulose derivatives (cellulosics) can provide various benefits when used in virtually all types of dosage forms. Nevertheless, the popularity of their use in approved drug products is rather unknown. This research reports the current prevalence and trends of use for 15 common cellulosics in prescription drug products. The cellulosics were powdered and microcrystalline cellulose (MCC), ethyl cellulose, hydroxypropyl cellulose (HPC), hydroxyethyl cellulose (HEC), hypromellose (HPMC), HPMC phthalate, HPMC acetate succinate, cellulose acetate (CA), CA phthalate, sodium (Na) and calcium (Ca) carboxymethylcellulose (CMC), croscarmellose sodium (XCMCNa), methyl cellulose, and low substituted HPC. The number of brand drug products utilizing each cellulosics was determined using the online drug index Rxlist. A total of 607 brand products were identified having one or more of the cellulosics as an active or inactive ingredient. An array of various dosage forms was identified and revealed HPMC and MCC to be the most utilized cellulosics in all products followed by XCMCNa and HPC. Many products contained two or more cellulosics in the formulation (42% containing two, 23% containing three, and 4% containing 4-5). The largest combination occurrence was HPMC with MCC. The use of certain cellulosics within different dosage form types was found to contain specific trends. All injectables utilized only CMCNa, and the same with all ophthalmic solutions utilizing HPMC, and otic suspensions utilizing HEC. Popularity and trends regarding cellulosics use may occur based on many factors including functionality, safety, availability, stability, and ease of manufacturing.

  12. Studies on improvement of tomato productivity in a large-scale greenhouse: Prediction of tomato yield based on integrated solar radiation

    International Nuclear Information System (INIS)

    Hisaeda, K.; Nishina, H.

    2007-01-01

    As there are currently many large-scale production facilities that have contracts with the large retailing companies, accurate prediction of yield is necessary. The present study developed a method to predict tomato yield accurately using the data on the outside solar radiation. The present study was conducted in a Venlo-type greenhouse (29,568 square m) at Sera Farm Co., Ltd. in Sera-cho in Hiroshima prefecture. The cultivar used for this experiment was plum tomato. The sowing took place on July 18, the planting took place on August 30, and the harvesting started on October 9, 2002. The planting density was 2.5 plants msup(-2). As the results of the analysis of correlation between the weekly tomato yield and the integrated solar radiation for the period from October 7 to July 28 (43 weeks), the highest correlation (r = 0.518) between the weekly tomato yield and the solar radiation integrated from seven to one weeks before the harvesting was observed. Further investigation by the same correlation analysis was conducted for the 25 weeks period from December 8 to May 26, during which time the effect of growing stages and air temperature were considered to be relatively small. The results showed the highest correlation (r = 0.730) between the weekly tomato yield and the solar radiation integrated from eight to one weeks before the harvesting. The tomato yield occasionally needed to be adjusted at Sera Farm. Consequently, the correlation between the three-week moving average of tomato yield and the integrated solar radiation was calculated. The results showed the highest correlation was obtained for the period from eight to one weeks before the harvesting (r = 0.860). This study therefore showed that it was possible to predict the tomato yield (y: kg.msup(-2).weeksup(-1)) using the following equation on the solar radiation integrated from eight to one weeks before the harvesting(x: MJ.msup(-2)): y = 7.50 x 10 sup(-6)x + 0.148 (rsup(2) = 0.740)

  13. SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K; Zhang, Y; Sen, H; Lediju Bell, M; Goldstein, S; Kazanzides, P; Iordachita, I; Wong, J [Johns Hopkins University, Baltimore, MD (United States)

    2014-06-01

    Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613

  14. SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

    International Nuclear Information System (INIS)

    Ding, K; Zhang, Y; Sen, H; Lediju Bell, M; Goldstein, S; Kazanzides, P; Iordachita, I; Wong, J

    2014-01-01

    Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613

  15. Efficacy of an integrated continuing medical education (CME) and quality improvement (QI) program on radiation oncologist (RO) clinical practice

    International Nuclear Information System (INIS)

    Leong, Cheng Nang; Shakespeare, Thomas Philip; Mukherjee, Rahul K.; Back, Michael F.; Lee, Khai Mun; Lu, Jiade Jay; Wynne, Christopher J.; Lim, Keith; Tang, Johann; Zhang Xiaojian

    2006-01-01

    Purpose: There has been little radiation oncologist (RO)-specific research in continuing medical education (CME) or quality improvement (QI) program efficacy. Our aim was to evaluate a CME/QI program for changes in RO behavior, performance, and adherence to department protocols/studies over the first 12 months of the program. Methods and Materials: The CME/QI program combined chart audit with feedback (C-AWF), simulation review AWF (SR-AWF), reminder checklists, and targeted CME tutorials. Between April 2003 and March 2004, management of 75 patients was evaluated by chart audit with feedback (C-AWF) and 178 patients via simulation review audit (SR-AWF) using a validated instrument. Scores were presented, and case management was discussed with individualized educational feedback. RO behavior and performance was compared over the first year of the program. Results: Comparing the first and second 6 months, there was a significant improvement in mean behavior (12.7-13.6 of 14, p = 0.0005) and RO performance (7.6-7.9 of 8, p = 0.018) scores. Protocol/study adherence significantly improved from 90.3% to 96.6% (p = 0.005). A total of 50 actions were generated, including the identification of learning needs to direct CME tutorials, the systematic change of suboptimal RO practice, and the alteration of deficient management of 3% of patients audited during the program. Conclusion: An integrated CME/QI program combining C-AWF, SR-AWF, QI reminders, and targeted CME tutorials effectively improved targeted RO behavior and performance over a 12-month period. There was a corresponding increase in departmental protocol and study adherence

  16. Evaluating Changes to Blood-Brain Barrier Integrity in Brain Metastasis over Time and after Radiation Treatment

    Directory of Open Access Journals (Sweden)

    Donna H. Murrell

    2016-06-01

    Full Text Available INTRODUCTION: The incidence of brain metastasis due to breast cancer is increasing, and prognosis is poor. Treatment is challenging because the blood-brain barrier (BBB limits efficacy of systemic therapies. In this work, we develop a clinically relevant whole brain radiotherapy (WBRT plan to investigate the impact of radiation on brain metastasis development and BBB permeability in a murine model. We hypothesize that radiotherapy will decrease tumor burden and increase tumor permeability, which could offer a mechanism to increase drug uptake in brain metastases. METHODS: Contrast-enhanced magnetic resonance imaging (MRI and high-resolution anatomical MRI were used to evaluate BBB integrity associated with brain metastases due to breast cancer in the MDA-MB-231-BR-HER2 model during their natural development. Novel image-guided microirradiation technology was employed to develop WBRT treatment plans and to investigate if this altered brain metastatic growth or permeability. Histology and immunohistochemistry were performed on whole brain slices corresponding with MRI to validate and further investigate radiological findings. RESULTS: Herein, we show successful implementation of microirradiation technology that can deliver WBRT to small animals. We further report that WBRT following diagnosis of brain metastasis can mitigate, but not eliminate, tumor growth in the MDA-MB-231-BR-HER2 model. Moreover, radiotherapy did not impact BBB permeability associated with metastases. CONCLUSIONS: Clinically relevant WBRT is not curative when delivered after MRI-detectable tumors have developed in this model. A dose of 20 Gy in 2 fractions was not sufficient to increase tumor permeability such that it could be used as a method to increase systemic drug uptake in brain metastasis.

  17. Radiation hormesis in plant

    International Nuclear Information System (INIS)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Cun, Ki Jung; Shin, In Chul; Lim, Young Taek

    1999-04-01

    This research was performed to investigate the effects of low dose γ-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as acid rain or soil types could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant enzyme (POD) were accomplished in the plant irradiated with difference dosage of γ-ray

  18. Radiation hormesis in plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Sung; Song, Hi Sup; Lee, Young Keun; Cun, Ki Jung; Shin, In Chul; Lim, Young Taek

    1999-04-01

    This research was performed to investigate the effects of low dose {gamma}-ray radiation on the seed germination and the following physiological responses in vegetable crops. Special attention was focused on whether the resistance of vegetables against the unfavorable conditions of environment such as acid rain or soil types could be enhanced as an aspect of radiation hormesis. Analysis and characterization of antioxidant enzyme from plant culture cells and radiation tolerant of transformed plants from antioxidant enzyme (POD) were accomplished in the plant irradiated with difference dosage of {gamma}-ray.

  19. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with the design and measurement of physical parameters used in theory or to support biological experiments. The radiation biophysics program tests and uses the theoretical developments for experimental design, and provides information for further theoretical development through experiments on cellular systems

  20. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with design and measurement of those physical parameters used in the theory or to support biological experiments. The radiation biophysics program tests and makes use of the theoretical developments for experimental design. Also, this program provides information for further theoretical development through experiments on cellular systems

  1. 21 CFR 330.3 - Imprinting of solid oral dosage form drug products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Imprinting of solid oral dosage form drug products... AS SAFE AND EFFECTIVE AND NOT MISBRANDED General Provisions § 330.3 Imprinting of solid oral dosage form drug products. A requirement to imprint an identification code on solid oral dosage form drug...

  2. 21 CFR 522.1696 - Penicillin G procaine implantation and injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin G procaine implantation and injectable dosage forms. 522.1696 Section 522.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... DOSAGE FORM NEW ANIMAL DRUGS § 522.1696 Penicillin G procaine implantation and injectable dosage forms. ...

  3. 21 CFR 524.1662 - Oxytetracycline hydrochloride ophthalmic and topical dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride ophthalmic and topical dosage forms. 524.1662 Section 524.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662 Oxytetracycline hydrochloride ophthalmic and topical dosage forms. ...

  4. Second Cancer Risk after simultaneous integrated boost radiation therapy of right sided breast cancer with and without flattening filter

    Energy Technology Data Exchange (ETDEWEB)

    Dobler, Barbara; Maier, Johannes; Knott, Bernadette; Maerz, Manuel; Koelbl, Oliver [Regensburg University Medical Center, Department of Radiotherapy, Regensburg (Germany); Loeschel, Rainer [Ostbayerische Technische Hochschule Regensburg, Faculty of Computer Science and Mathematics, Regensburg (Germany)

    2016-10-15

    The aim of this study was to investigate if the flattening filter free mode (FFF) of a linear accelerator reduces the excess absolute risk (EAR) for second cancer as compared to the flat beam mode (FF) in simultaneous integrated boost (SIB) radiation therapy of right-sided breast cancer. Six plans were generated treating the whole breast to 50.4 Gy and a SIB volume to 63 Gy on CT data of 10 patients: intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and a tangential arc VMAT (tVMAT), each with flattening filter and without. The EAR was calculated for the contralateral breast and the lungs from dose-volume histograms (DVH) based on the linear-exponential, the plateau, and the full mechanistic dose-response model. Peripheral low-dose measurements were performed to compare the EAR in more distant regions as the thyroids and the uterus. FFF reduces the EAR significantly in the contralateral and peripheral organs for tVMAT and in the peripheral organs for VMAT. No reduction was found for IMRT. The lowest EAR for the contralateral breast and lung was achieved with tVMAT FFF, reducing the EAR by 25 % and 29 % as compared to tVMAT FF, and by 44 % to 58 % as compared to VMAT and IMRT in both irradiation modes. tVMAT FFF showed also the lowest peripheral dose corresponding to the lowest EAR in the thyroids and the uterus. The use of FFF mode allows reducing the EAR significantly when tVMAT is used as the treatment technique. When second cancer risk is a major concern, tVMAT FFF is considered the preferred treatment option in SIB irradiation of right-sided breast cancer. (orig.) [German] Ziel der Studie war es zu untersuchen, ob der ausgleichskoerperfreie Modus (FFF) bei der simultan integrierten Boost-(SIB-)Bestrahlung des rechtsseitigen Mammakarzinoms eine Reduktion des strahleninduzierten Sekundaermalignomrisikos (''excess absolute risk'', EAR) im Vergleich zur Bestrahlung mit Ausgleichskoerper (FF) erlaubt. Auf CT

  5. High dosages of sermion (30-60 mg per day) neuropsychiatric efficacy for encephalopathy monotherapy in irradiated patients

    International Nuclear Information System (INIS)

    Nyagu, A.I.; Loganovskij, K.N.; Yur'ev, K.L.; Petrova, I.V.; Bomko, M.A.

    1999-01-01

    Open randomised with parallel groups clinical trial was carried out for an assessment of neuropsychiatric efficacy of monotherapy by high dosages of Sermion (30-60 mg per day) in 57 liquidators at the age of 33-65 years irradiated by 50-900 mGy with organic mental disorders (encephalopathy) occurred following cleaning up works in the Chernobyl exclusion zone in 1986-1987. According to the obtained results Sermion 30-60 mg per day may be recommended for the treatment of patients with organic mental disorders (encephalopathy) exposed to ionising radiation

  6. Radiation effect on polyethylene tube operational properties

    International Nuclear Information System (INIS)

    Kagan, D.F.; Kantor, L.A.; Sokolov, I.A.; Pogrebetskij, G.E.; Perlova, N.A.; Chumakov, V.V.

    1975-01-01

    The operational properties (stability on prolonged usage and creeping) were determined for pressure pipes made of high-density and low-density polyethylene subjected to γ-radiation. The dependence of the period up to the breaking point on the radiation dosage was extreme in character, with a maximum being near 25 Mrad. With an increase in the irradiation dosage the character of the breaking changes from plastic (at 0-15 Mrad) to brittle (at higher dosages). The plots of creepage, indepent from the amount of radiation, can be described by logarithmic equation epsilon=epsilonsub(0)+K lgt (where, epsilon-deformation of creepage, %; epsilonsub(0)- and K - creepage constants). Therefore creepage can be considered as a criterion determining the carrying capacity of the γ-irradiated polyethylene. It was established that only radiation-grafted high-density polyethylene is suitable for hot water supply pipes

  7. Optimized radiation of pelvic volumes in the clinical setting by using a novel bellyboard with integrated gonadal shielding

    International Nuclear Information System (INIS)

    Hollenhorst, Helmut; Schaffer, Moshe; Romano, Mario; Reiner, Michael; Siefert, Axel; Schaffer, Pamela; Quanz, Anton; Duehmke, Eckhart

    2004-01-01

    The purpose of this study was to determine the feasibility of a custom-made, modified bellyboard to reduce radiotherapy side effects on small bowel, bladder, skin, and male gonads. Two groups of 10 consecutive patients each were treated from January 2003 through April 2003 with neoadjuvant (45 Gy) or adjuvant (54 Gy) radio(chemo)therapy in single fractions of 5 days a week 1.8 Gy for rectal carcinoma, using a photon energy of 15 MV. One group was positioned in a prone position without an immobilization device, the other group was positioned on our bellyboard. Treatment planning was calculated by using a 4- and a 3-field box technique. Differences in the dose of organs of risk were calculated. For 1 male patient, a gonadal shielding was developed and integrated. All patients examined with the bellyboard demonstrated an anterior and cranial dislocation of the small bowel. Using a 4-field box, the mean dose to the small bowel of patients treated on our bellyboard was 56.5% as compared to 63.1% when treated without the bellyboard. When a 3-field box was used, the mean dose to the small bowel was 52.4% when the bellyboard was used, as compared to a mean dose of 63.1% without the bellyboard. Regarding the dose volume effects to the bladder, the mean dose for patients treated with a 4-field box was about 14.5% higher as compared to patients treated with a 3-field box. The mean dose to the hip joints and skin also depended on the radiation technique. The patient who received gonadal shielding received a maximal total gonadal dose of about 75.0 cGy in single fractions of maximal 3.0 cGy (TL-dosimeters). Daily setup variations evaluated by a beam's-eye view were similar in both groups and ranged from 0.5 cm 1.0 cm. For daily use, our bellyboard appears to be an ideal compromise due to effectiveness, its easy handling, and reproductive positioning; moreover, it can also be used in combination with gonadal shielding

  8. Mechanisms and evolutionary patterns of mammalian and avian dosage compensation.

    Directory of Open Access Journals (Sweden)

    Philippe Julien

    Full Text Available As a result of sex chromosome differentiation from ancestral autosomes, male mammalian cells only contain one X chromosome. It has long been hypothesized that X-linked gene expression levels have become doubled in males to restore the original transcriptional output, and that the resulting X overexpression in females then drove the evolution of X inactivation (XCI. However, this model has never been directly tested and patterns and mechanisms of dosage compensation across different mammals and birds generally remain little understood. Here we trace the evolution of dosage compensation using extensive transcriptome data from males and females representing all major mammalian lineages and birds. Our analyses suggest that the X has become globally upregulated in marsupials, whereas we do not detect a global upregulation of this chromosome in placental mammals. However, we find that a subset of autosomal genes interacting with X-linked genes have become downregulated in placentals upon the emergence of sex chromosomes. Thus, different driving forces may underlie the evolution of XCI and the highly efficient equilibration of X expression levels between the sexes observed for both of these lineages. In the egg-laying monotremes and birds, which have partially homologous sex chromosome systems, partial upregulation of the X (Z in birds evolved but is largely restricted to the heterogametic sex, which provides an explanation for the partially sex-biased X (Z expression and lack of global inactivation mechanisms in these lineages. Our findings suggest that dosage reductions imposed by sex chromosome differentiation events in amniotes were resolved in strikingly different ways.

  9. Intra-individual comparison of PET/CT with different body weight-adapted FDG dosage regimens

    International Nuclear Information System (INIS)

    Geismar, Jan H; Stolzmann, Paul; Sah, Bert-Ram; Burger, Irene A; Seifert, Burkhardt; Delso, Gaspar; Schulthess, Gustav K von; Veit-Haibach, Patrick; Husmann, Lars

    2015-01-01

    18F-2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/ computed tomography (CT) imaging demands guidelines to safeguard sufficient image quality at low radiation exposure. Various FDG dose regimes have been investigated; however, body weight-adapted dose regimens and related image quality (IQ) have not yet been compared in the same patient. To investigate the relationship between FDG dosage and image quality in PET/CT in the same patient and determine prerequisites for low dosage scanning. This study included 61 patients undergoing a clinically indicated PET/CT imaging study and follow-up with a normal (NDS, 5 MBq/kg body weight [BW]) and low dosage scanning protocol (LDS, 4 MBq/kg BW), respectively, using a Discovery VCT64 scanner. Two blinded and independent readers randomly assessed IQ of PET using a 5-point Likert scale and signal-to-noise ratio (SNR) of the liver. Body mass index (BMI) was significantly lower at LDS (P = 0.021) and represented a significant predictor of SNR at both NDS (P < 0.001) and LDS (P = 0.005). NDS with a mean administered activity of 340 MBq resulted in significantly higher IQ (P < 0.001) and SNR as compared with LDS with a mean of 264 MBq (F-value = 23.5, P < 0.001, mixed model ANOVA adjusted for covariate BMI). Non-diagnostic IQ at LDS was associated with a BMI > 22 kg/m 2 . FDG dosage significantly predicts IQ and SNR in PET/CT imaging as demonstrated in the same patient with optimal IQ achieved at 5 MBq/kg BM. PET/CT imaging at 4 MBq/kg BW may only be recommended in patients with a BMI ≤ 22 kg/m 2 to maintain diagnostic IQ

  10. [Study on dosage form design for improving oral bioavailability of traditional Chinese medicines].

    Science.gov (United States)

    Xia, Hai-Jian; Zhang, Zhen-Hai; Yao, Dong-Dong; Jia, Xiao-Bin

    2013-09-01

    Both chemical drugs and traditional Chinese medicines have the problem of low bioavailability. However, as traditional Chinese medicines are a multi-component complex, their dosage forms are required to be designed in line with their characteristics, in order to improve the bioavailability of traditional Chinese medicines. Traditional Chinese medicines are mostly prepared into pill, powder, paste, elixir and decoction, but with such drawbacks as high administration dose and poor efficacy. With the process of modernization of traditional Chinese medicines, new-type preparations have be developed and made outstanding achievements. However, they fail to make an organic integration between traditional Chinese medicine theories and modern preparation theories. Characteristics of traditional Chinese medicines are required to be taken into account during the development of traditional Chinese medicines. In the article, multi-component preparation technology was adopted to establish a multi-component drug release system of traditional Chinese medicines on the basis of multiple components of traditional Chinese medicines.

  11. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  12. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 108 2

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1 SIN 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  13. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  14. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, 08

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  15. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization

    Directory of Open Access Journals (Sweden)

    Thanos Manos

    2018-04-01

    Full Text Available In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce

  16. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization.

    Science.gov (United States)

    Manos, Thanos; Zeitler, Magteld; Tass, Peter A

    2018-01-01

    In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR) stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS) robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate) is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS) turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce long

  17. Comprehensive review on additives of topical dosage forms for drug delivery.

    Science.gov (United States)

    Garg, Tarun; Rath, Goutam; Goyal, Amit K

    2015-12-01

    Skin is the largest organ of the human body and plays the most important role in protecting against pathogen and foreign matter. Three important modes such as topical, regional and transdermal are widely used for delivery of various dosage forms. Among these modes, the topical dosage forms are preferred because it provides local therapeutic activity when applied to the skin or mucous membranes. Additives or pharmaceutical excipients (non-drug component of dosage form) are used as inactive ingredients in dosage form or tools for structuring dosage forms. The main use of topical dosage form additives are controling the extent of absorption, maintaining the viscosity, improving the stability as well as organoleptic property and increasing the bulk of the formulation. The overall goal of this article is to provide the clinician with information related to the topical dosage form additives and their current major applications against various diseases.

  18. Radiation Protection in PET-CT

    International Nuclear Information System (INIS)

    2011-10-01

    The presentation is based on the following areas: radiological monitoring installations in the production of PET radiopharmaceuticals, personal dose, dosage advertising, nuclear medicine, PET, radiation protection of patients, requirements for medical practice, regulatory aspects, dose calculation, shields, quantities, center Cudim, cyclotron and synthesis of radiopharmaceuticals, biological effects of radiation protection practices.

  19. Development and characterization of a gastroretentive dosage form composed of chitosan and hydroxyethyl cellulose for alendronate

    Directory of Open Access Journals (Sweden)

    Chen YC

    2013-12-01

    Full Text Available Ying-Chen Chen,1,* Hsiu-O Ho,1,* Chiao-Chi Chiu,1 Ming-Thau Sheu1,2 1School of Pharmacy, College of Pharmacy, Taipei Medical University, 2Clinical Research Center and Traditional Herbal Medicine Research Center, Taipei Medical University Hospital, Taipei, Taiwan*These authors contributed equally to this workAbstract: In this study, alendronate, the most commonly used biphosphonate for treating osteoporosis, was formulated as gastroretentive dosage form (GRDF tablets to enhance its oral bioavailability. GRDF tablets were characterized with the effects of different molecular weights (MWs of chitosan (CS and hydroxyethyl cellulose (HEC at various ratios on swelling, floating, and physical integrity. The CS component was formed using various acids: acetic, lactic, malic, succinic, and citric, and a high viscosity grade of HEC was selected. The results demonstrated that the swelling ratios of the formulations comprising high MW CS were lower than those of low or medium MW CS when salts were formed with any countering acids except for acetic acid. The decreasing ranking of the swelling rates was: CS-citrate > CS-malate > CS-lactate > CS-succinate > CS-acetate. A negative correlation was found between the pKa of the respective countering acid and the swelling rate. The swelling rate was promoted if an acidic salt of CS with a lower water content was incorporated, while it became slower when tablet hardness was higher or the compression force to form tablets was increased. Although HEC did not contribute to swelling or floating, it played a role in maintaining structural integrity. A prolonged dissolution profile of alendronate GRDF tablets developed in this study was observed.Keywords: gastroretentive dosage form, chitosan, hydrogel, hydroxyethyl cellulose, swelling, alendronate

  20. Clinical oncology based upon radiation biology

    International Nuclear Information System (INIS)

    Hirata, Hideki

    2016-01-01

    This paper discussed the biological effects of radiation as physical energy, especially those of X-ray as electromagnetic radiation, by associating the position of clinical oncology with classical radiation cell biology as well as recent molecular biology. First, it described the physical and biological effects of radiation, cell death due to radiation and recovery, radiation effects at tissue level, and location information and dosage information in the radiotherapy of cancer. It also described the territories unresolved through radiation biology, such as low-dose high-sensitivity, bystander effects, etc. (A.O.)

  1. A Ground-Based Analog for CNS Exposure to Space Radiation: A System for Integrating Microbeam Technology and Neuronal Culture

    Data.gov (United States)

    National Aeronautics and Space Administration — Problem Statement: The connection between radiation-induced neuronal damage and deficits in behavior and cellular function is still largely unknown. Previous studies...

  2. Peak radiated power measurement of the DOE Mark II container tag with integrated ST-676 sensor radio frequency identification device.

    Energy Technology Data Exchange (ETDEWEB)

    Jursich, Mark

    2010-04-01

    The total peak radiated power of the Department of Energy Mark II container tag was measured in the electromagnetic reverberation chamber facility at Sandia National Laboratories. The tag's radio frequency content was also evaluated for possible emissions outside the intentional transmit frequency band. No spurious emissions of any significance were found, and the radiated power conformed to the manufacturer's specifications.

  3. Gamma ray dosage and mutation breeding in St. Augustinegrass

    International Nuclear Information System (INIS)

    Busey, P.

    1980-01-01

    Stolon pieces of St. Augustinegrass [Stenotaphrum secundatum (Walt.) Kuntze] were irradiated with gamma rays in an attempt to cause mutations. A practical dosage for most genotypes was 4,500 rads. This dosage caused considerable (50%) growth retardation and a mean survival of about 40% of single-node cuttings. However, Bitterblue and another accession were entirely killed at 4,000 rads. At 4,500 rads, up to 7% recognizable mutants of accession FA-243 were obtained. This proportion resulted when irradiated cuttings were propagated clonally and observed for 1.5 years in replicated microplots. In addition to morphological variants, a chimeral anthocyanin change was noticed. From this chimera arose a stable genotype with green stolons and white stigmas, whereas the source genotype (FA-243) had red stolons and purple stigmas. Associated reduction in fertility from 56 to 0.6% suggested that the mutation arose as a small chromosome deletion. Mutation breeding is effective in improving St. Augustinegrass when easily recognizable variants are needed

  4. Biowaiver monographs for immediate release solid oral dosage forms: efavirenz.

    Science.gov (United States)

    Cristofoletti, Rodrigo; Nair, Anita; Abrahamsson, Bertil; Groot, D W; Kopp, Sabine; Langguth, Peter; Polli, James E; Shah, Vinod P; Dressman, Jennifer B

    2013-02-01

    Literature data pertaining to the decision to allow a waiver of in vivo bioequivalence testing for the approval of immediate-release (IR) solid oral dosage forms containing efavirenz as the only active pharmaceutical ingredient (API) are reviewed. Because of lack of conclusive data about efavirenz's permeability and its failure to comply with the "high solubility" criteria according to the Biopharmaceutics Classification System (BCS), the API can be classified as BCS Class II/IV. In line with the solubility characteristics, the innovator product does not meet the dissolution criteria for a "rapidly dissolving product." Furthermore, product variations containing commonly used excipients or in the manufacturing process have been reported to impact the rate and extent of efavirenz absorption. Despite its wide therapeutic index, subtherapeutic levels of efavirenz can lead to treatment failure and also facilitate the emergence of efavirenz-resistant mutants. For all these reasons, a biowaiver for IR solid oral dosage forms containing efavirenz as the sole API is not scientifically justified for reformulated or multisource drug products. Copyright © 2012 Wiley Periodicals, Inc.

  5. Gamma scintigraphy in the evaluation of pharmaceutical dosage forms

    International Nuclear Information System (INIS)

    Davis, S.S.; Hardy, J.G.; Newman, S.P.; Wilding, I.R.

    1992-01-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical drug delivery systems. It is used particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate technetium-99m or indium-111 labelled radiopharmaceutical into the formulation. In the case of complex dosage forms, such as enteric-coated tablets, labelling is best undertaken by the addition of a non-radioactive tracer such as samarium-152 or erbium-170 followed by neutron activation of the final product. Systems investigated include tablets and multiparticulates for oral administration, enemas and suppositories, metered dose inhalers and nebulisers, and nasal sprays and drops. Gamma-scintigraphy provides information on the deposition, dispersion and movement of the formulation. The combination of such studies with the assay of drug levels in blood or urine specimens, pharmacoscintigraphy, provides information concerning the sites of drug release and absorption. Data acquired from the scintigraphic evaluation of pharmaceutical dosage forms are now being used increasingly at all stages of product development, from the assessment of prototype delivery systems to supporting the product licence application. (orig.)

  6. Emergence of 3D Printed Dosage Forms: Opportunities and Challenges.

    Science.gov (United States)

    Alhnan, Mohamed A; Okwuosa, Tochukwu C; Sadia, Muzna; Wan, Ka-Wai; Ahmed, Waqar; Arafat, Basel

    2016-08-01

    The recent introduction of the first FDA approved 3D-printed drug has fuelled interest in 3D printing technology, which is set to revolutionize healthcare. Since its initial use, this rapid prototyping (RP) technology has evolved to such an extent that it is currently being used in a wide range of applications including in tissue engineering, dentistry, construction, automotive and aerospace. However, in the pharmaceutical industry this technology is still in its infancy and its potential yet to be fully explored. This paper presents various 3D printing technologies such as stereolithographic, powder based, selective laser sintering, fused deposition modelling and semi-solid extrusion 3D printing. It also provides a comprehensive review of previous attempts at using 3D printing technologies on the manufacturing dosage forms with a particular focus on oral tablets. Their advantages particularly with adaptability in the pharmaceutical field have been highlighted, which enables the preparation of dosage forms with complex designs and geometries, multiple actives and tailored release profiles. An insight into the technical challenges facing the different 3D printing technologies such as the formulation and processing parameters is provided. Light is also shed on the different regulatory challenges that need to be overcome for 3D printing to fulfil its real potential in the pharmaceutical industry.

  7. Gamma scintigraphy in the evaluation of pharmaceutical dosage forms

    Energy Technology Data Exchange (ETDEWEB)

    Davis, S.S.; Hardy, J.G.; Newman, S.P.; Wilding, I.R. (Pharmaceutical Profiles Ltd., Nottingham (United Kingdom))

    1992-11-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical drug delivery systems. It is used particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate technetium-99m or indium-111 labelled radiopharmaceutical into the formulation. In the case of complex dosage forms, such as enteric-coated tablets, labelling is best undertaken by the addition of a non-radioactive tracer such as samarium-152 or erbium-170 followed by neutron activation of the final product. Systems investigated include tablets and multiparticulates for oral administration, enemas and suppositories, metered dose inhalers and nebulisers, and nasal sprays and drops. Gamma-scintigraphy provides information on the deposition, dispersion and movement of the formulation. The combination of such studies with the assay of drug levels in blood or urine specimens, pharmacoscintigraphy, provides information concerning the sites of drug release and absorption. Data acquired from the scintigraphic evaluation of pharmaceutical dosage forms are now being used increasingly at all stages of product development, from the assessment of prototype delivery systems to supporting the product licence application. (orig.).

  8. Maintenance and Loss of Duplicated Genes by Dosage Subfunctionalization.

    Science.gov (United States)

    Gout, Jean-Francois; Lynch, Michael

    2015-08-01

    Whole-genome duplications (WGDs) have contributed to gene-repertoire enrichment in many eukaryotic lineages. However, most duplicated genes are eventually lost and it is still unclear why some duplicated genes are evolutionary successful whereas others quickly turn to pseudogenes. Here, we show that dosage constraints are major factors opposing post-WGD gene loss in several Paramecium species that share a common ancestral WGD. We propose a model where a majority of WGD-derived duplicates preserve their ancestral function and are retained to produce enough of the proteins performing this same ancestral function. Under this model, the expression level of individual duplicated genes can evolve neutrally as long as they maintain a roughly constant summed expression, and this allows random genetic drift toward uneven contributions of the two copies to total expression. Our analysis suggests that once a high level of imbalance is reached, which can require substantial lengths of time, the copy with the lowest expression level contributes a small enough fraction of the total expression that selection no longer opposes its loss. Extension of our analysis to yeast species sharing a common ancestral WGD yields similar results, suggesting that duplicated-gene retention for dosage constraints followed by divergence in expression level and eventual deterministic gene loss might be a universal feature of post-WGD evolution. © The Author 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. ORODISPERSIBLE TABLET: A Patient Friendly Dosage Form (a Review

    Directory of Open Access Journals (Sweden)

    C. K. Rameesa

    2015-03-01

    Full Text Available Background: The most common and preferred route of drug administration is through the oral route. Orodispersible tablets are gaining importance among novel oral drug delivery system as they have improved patient compliance and have some additional advantages compared to other formulation. They are also solid unit dosage forms, which disintegrate in the mouth within a minute in the presence of saliva due to superdisintegrants in the formulation. Thus this type of drug delivery helps a proper per oral administration in pediatric and geriatric population where swallowing is a matter of trouble. Various scientists have prepared orodispersible tablets by following various methods. However, the most common method is the direct compression method. Other special methods are Freeze Drying,Tablet Molding, Sublimation, Spray Drying, Mass extrusion, Phase transition process, etc. Since these tablets dissolve directly in the mouth, so, their taste is also an important factor. Various approaches have been taken in order to mask the bitter taste of the drug. A number of scientists have explored several drugs in this field. Like all other solid dosage forms, they are also evaluated in the field of hardness, friability, wetting time, moisture uptake, disintegration test and dissolution test.

  10. Stability of pharmaceutical salts in solid oral dosage forms.

    Science.gov (United States)

    Nie, Haichen; Byrn, Stephen R; Zhou, Qi Tony

    2017-08-01

    Using pharmaceutical salts in solid dosage forms can raise stability concerns, especially salt dissociation which can adversely affect the product performance. Therefore, a thorough understanding of the salt instability encountered in solid-state formulations is imperative to ensure the product quality. The present article uses the fundamental theory of acid base, ionic equilibrium, relationship of pH and solubility as a starting point to illustrate and interpret the salt formation and salt disproportionation in pharmaceutical systems. The criteria of selecting the optimal salt form and the underlying theory of salt formation and disproportionation are reviewed in detail. Factors influencing salt stability in solid dosage forms are scrutinized and discussed with the case studies. In addition, both commonly used and innovative strategies for preventing salt dissociations in formulation, on storage and during manufacturing will be suggested herein. This article will provide formulation scientists and manufacturing engineers an insight into the mechanisms of salt disproportionation and salt formation, which can help them to avoid and solve the instability issues of pharmaceutical salts in the product design.

  11. Microscopic integral cross section measurements in the Be(d,n) neutron spectrum for applications in neutron dosimetry, radiation damage and the production of long-lived radionuclides

    International Nuclear Information System (INIS)

    Smith, D.L.; Meadows, J.W.; Greenwood, L.R.

    1990-01-01

    Integral neutron-reaction cross sections have been measured, relative to the U-238 neutron fission cross-section standard, for 27 reactions which are of contemporary interest in various nuclear applications (e.g., fast-neutron dosimetry, neutron radiation damage and the production of long-lived activities which affect nuclear waste disposal). The neutron radiation field employed in this study was produced by bombarding a thick Be-metal target with 7-MeV deuterons from an accelerator. The experimental results are reported along with detailed information on the associated measurement uncertainties and their correlations. These data are also compared with corresponding calculated values, based on contemporary knowledge of the differential cross sections and of the Be(d,n) neutron spectrum. Some conclusions are reached on the utility of this procedure for neutron-reaction data testing

  12. Automatic dosage of hydrogen peroxide in solar photo-Fenton plants: Development of a control strategy for efficiency enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Ortega-Gomez, E. [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain); Moreno Ubeda, J.C. [Department of Language and Computation, University of Almeria, 04120 Almeria (Spain); Alvarez Hervas, J.D. [Department of Language and Computation, University of Almeria, 04120 Almeria (Spain); Department of Language and Computation, University of Sevilla, 41092 Sevilla (Spain); Casas Lopez, J.L.; Santos-Juanes Jorda, L. [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain); Sanchez Perez, J.A., E-mail: jsanchez@ual.es [Department of Chemical Engineering, University of Almeria, 04120 Almeria (Spain); CIESOL, Joint Centre of the University of Almeria-CIEMAT, 04120 Almeria (Spain)

    2012-10-30

    Highlights: Black-Right-Pointing-Pointer Dissolved oxygen monitoring is used for automatic dosage of H{sub 2}O{sub 2} in photo-Fenton. Black-Right-Pointing-Pointer PI with anti-windup minimises H{sub 2}O{sub 2} consumption. Black-Right-Pointing-Pointer The H{sub 2}O{sub 2} consumption was reduced up to 50% with respect to manual addition strategies. Black-Right-Pointing-Pointer Appropriate H{sub 2}O{sub 2} dosage is achieved by PI with anti-windup under disturbances. - Abstract: The solar photo-Fenton process is widely used for the elimination of pollutants in aqueous effluent and, as such, is amply cited in the literature. In this process, hydrogen peroxide represents the highest operational cost. Up until now, manual dosing of H{sub 2}O{sub 2} has led to low process performance. Consequently, there is a need to automate the hydrogen peroxide dosage for use in industrial applications. As it has been demonstrated that a relationship exists between dissolved oxygen (DO) concentration and hydrogen peroxide consumption, DO can be used as a variable in optimising the hydrogen peroxide dosage. For this purpose, a model was experimentally obtained linking the dynamic behaviour of DO to hydrogen peroxide consumption. Following this, a control system was developed based on this model. This control system - a proportional and integral controller (PI) with an anti-windup mechanism - has been tested experimentally. The assays were carried out in a pilot plant under sunlight conditions and with paracetamol used as the model pollutant. In comparison with non-assisted addition methods (a sole initial or continuous addition), a decrease of 50% in hydrogen peroxide consumption was achieved when the automatic controller was used, driving an economic saving and an improvement in process efficiency.

  13. Theory of differential and integral scattering of laser radiation by a dielectric surface taking a defect layer into account

    NARCIS (Netherlands)

    Azarova, VV; Dmitriev, VG; Lokhov, YN; Malitskii, KN

    The differential and integral light scattering by dielectric surfaces is studied theoretically taking a thin nearsurface defect layer into account. The expressions for the intensities of differential and total integral scattering are found by the Green function method. Conditions are found under

  14. Guidance and control of MIR TDL radiation via flexible hollow metallic rectangular pipes and fibers for possible LHS and other optical system compaction and integration

    Science.gov (United States)

    Yu, C.

    1983-01-01

    Flexible hollow metallic rectangular pipes and infrared fibers are proposed as alternate media for collection, guidance and manipulation of mid-infrared tunable diode laser (TDL) radiation. Certain features of such media are found to be useful for control of TDL far field patterns, polarization and possibly intensity fluctuations. Such improvement in dimension compatibility may eventually lead to laser heterodyne spectroscopy (LHS) and optical communication system compaction and integration. Infrared optical fiber and the compound parabolic coupling of light into a hollow pipe waveguide are discussed as well as the design of the waveguide.

  15. Note: A 102 dB dynamic-range charge-sampling readout for ionizing particle/radiation detectors based on an application-specific integrated circuit (ASIC)

    Science.gov (United States)

    Pullia, A.; Zocca, F.; Capra, S.

    2018-02-01

    An original technique for the measurement of charge signals from ionizing particle/radiation detectors has been implemented in an application-specific integrated circuit form. The device performs linear measurements of the charge both within and beyond its output voltage swing. The device features an unprecedented spectroscopic dynamic range of 102 dB and is suitable for high-resolution ion and X-γ ray spectroscopy. We believe that this approach may change a widespread paradigm according to which no high-resolution spectroscopy is possible when working close to or beyond the limit of the preamplifier's output voltage swing.

  16. Studies of the effects of ultraviolet radiation on the structural integrities of ribosomal RNA components of the Escherichia coli 50S ribosomal subunit

    International Nuclear Information System (INIS)

    Gorelic, L.; Parker, D.

    1978-01-01

    The effects of 254-nm radiation on the structural integrities of free and 50S ribosome-bound 5S and 23S ribosomal ribonucleic acids (rRNA) have been elucidated. Irradiation of aqueous solutions of Escherichia coli 50S ribosomes with 253.7-nm radiation results in the formation of single-strand breaks in double-stranded regions of the 23S rRNA component, but not in rRNA chain scission, and destabilization of the secondary structure of the 23S rRNA toward denaturation. The minimum doses of 253.7-nm radiation required for the first detection of the two effects are 7 x 10 19 quanta for the production of single-strand breaks in double-stranded regions of the 23S rRNA, and 19 quanta for destabilization of the 23S rRNA secondary structure. Free 23S rRNA is resistant toward photoinduced chain breakage at doses of 253.7-nm radiation up to at least 2.3 x 10 20 and is much less sensitive toward destabilization of secondary structure than ribosome-bound 23S rRNA. In contrast to the photosensitivity of 50S ribosome-bound 23S rRNA toward chain breakage, 50S ribosome-bound 5S rRNA is resistant toward chain breakage at doses of 253.7-nm radiation up to at least 2.3 x 10 20 quanta. Ribosome-bound 5S and 23S rRNA are also not photosensitive toward intermolecular 5S/23S rRNA cross-linkage

  17. Analysis of a Statistical Relationship Between Dose and Error Tallies in Semiconductor Digital Integrated Circuits for Application to Radiation Monitoring Over a Wireless Sensor Network

    Science.gov (United States)

    Colins, Karen; Li, Liqian; Liu, Yu

    2017-05-01

    Mass production of widely used semiconductor digital integrated circuits (ICs) has lowered unit costs to the level of ordinary daily consumables of a few dollars. It is therefore reasonable to contemplate the idea of an engineered system that consumes unshielded low-cost ICs for the purpose of measuring gamma radiation dose. Underlying the idea is the premise of a measurable correlation between an observable property of ICs and radiation dose. Accumulation of radiation-damage-induced state changes or error events is such a property. If correct, the premise could make possible low-cost wide-area radiation dose measurement systems, instantiated as wireless sensor networks (WSNs) with unshielded consumable ICs as nodes, communicating error events to a remote base station. The premise has been investigated quantitatively for the first time in laboratory experiments and related analyses performed at the Canadian Nuclear Laboratories. State changes or error events were recorded in real time during irradiation of samples of ICs of different types in a 60Co gamma cell. From the error-event sequences, empirical distribution functions of dose were generated. The distribution functions were inverted and probabilities scaled by total error events, to yield plots of the relationship between dose and error tallies. Positive correlation was observed, and discrete functional dependence of dose quantiles on error tallies was measured, demonstrating the correctness of the premise. The idea of an engineered system that consumes unshielded low-cost ICs in a WSN, for the purpose of measuring gamma radiation dose over wide areas, is therefore tenable.

  18. Calculation of radiation field integrals for higher-order basis functions in conical thin wire MoM formulation

    CSIR Research Space (South Africa)

    Lysko, AA

    2008-07-01

    Full Text Available stream_source_info LyskoA_2008.pdf.txt stream_content_type text/plain stream_size 24096 Content-Encoding UTF-8 stream_name LyskoA_2008.pdf.txt Content-Type text/plain; charset=UTF-8 On Calculation of Radiation Field... recursive manner. The speed performance of a Matlab implementation indicates that the presented method is favorable compared to the commercial software “WIPL-D” used as a reference. Key-Words: - antenna radiation patterns, moment methods, numerical...

  19. Effect of the geometrical parameters of an optical integrator on the unformity of the radiation flux distribution

    International Nuclear Information System (INIS)

    Vishnyakova, T.P.; Klychev, Sh.I.

    1992-01-01

    The use of optical mixers in the optical irradiators of simulators of direct and concentrated solar radiation has been proposed. In this paper, the parameters of an optical mixer are calculated geometrically, and the effect of the parameters of the optical mixer on the unformity of the irradiance distribution η of the radiation flux on the detector is investigated. These investigations show that the light distribution from an optical mixer is close to the characteristics of an ideal uniform emitter within the region from 0 to the limit of α. 5 refs., 4 figs

  20. Comparison of dosimetry distribution between three-dimension conformal and intensity modulated plan integrated with breath motion in postoperative radiation of gastric cancer

    International Nuclear Information System (INIS)

    Sun Wenjie; Zhang Zhen; Hu Weigang; Gu Weilie; Zhu Ji; Li Guichao; Cai Gang; Ma Xuejun

    2010-01-01

    Objective: To compare the dose distribution of the target and normal tissues in gastric cancers between three-dimension conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) plan when respiratory motion factors integrated in the plan. Methods: From January 2005 to November 2006, 10 patients with post-operatively radiation of gastric cancer were enrolled in this study. Planning CT were acquired conventionally with free-breath mode and the static treatment plans of the 3DCRT and IMRT were designed respectively. Probability distribution functions (PDF) were generated and convoluted with the static dose distributions from 3DCRT and IMRT plans to obtain the integrated plans. The dose distributions of the target and normal tissues were compared between 3DCRT and IMRT integration treatment plans, such as V 45 of clinical target volume, V 40 of liver and V 15 , V 18 of left and right kidney. Results: In the respiratory integrated treatment planning, the target volume coverage and homogeneity with IMRT are superior to those with 3DCRT ((V 45 98% : 87% (t = -3.35, P =0.010), mean dose 46.81 Gy ±0.75 Gy : 45.99 Gy ± 1.12 Gy (t = -0.31, P=0.020)). The V 40 of the liver in IMRT are smaller than those in 3DCRT ( 12% : 16%; t=3.75, P=0.010). For the left kidney, the V 15 and V 18 in IMRT are smaller than those in 3DCRT ((34% : 50% (t = 2.17, P = 0.050) and 27% : 46% (t = 3.11, P = 0.020) ),but for the right kidney, V 15 and V 18 in 3DCRT are smaller than those in IMRT ((15% : 21% (t = - 2.42, P=0.040) and 11% : 15% (t= -2.71, P=0.030)). Conclusions: When respiratory motion factor integrated in the treatment plan, IMRT showed advantage both in target coverage and normal tissue sparing in the high dose region of liver and left kidney. (authors)

  1. Oral Solid Dosage Form Disintegration Testing - The Forgotten Test.

    Science.gov (United States)

    Al-Gousous, Jozef; Langguth, Peter

    2015-09-01

    Since its inception in the 1930s, disintegration testing has become an important quality control (QC) test in pharmaceutical industry, and disintegration test procedures for various dosage forms have been described by the different pharmacopoeias, with harmonization among them still not quite complete. However, because of the fact that complete disintegration does not necessarily imply complete dissolution, much more research has been focused on dissolution rather than on disintegration testing. Nevertheless, owing to its simplicity, disintegration testing seems to be an attractive replacement to dissolution testing as recognized by the International Conference on Harmonization guidelines, in some cases. Therefore, with proper research being carried out to overcome the associated challenges, the full potential of disintegration testing could be tapped saving considerable efforts allocated to QC testing and quality assurance. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  2. Nanofibrous solid dosage form of living bacteria prepared by electrospinning

    Directory of Open Access Journals (Sweden)

    I. Wagner

    2014-05-01

    Full Text Available The aim of this work was to investigate the suitability of electrospinning for biodrug delivery and to develop an electrospinning-based method to produce vaginal drug delivery systems. Lactobacillus acidophilus bacteria were encapsulated into nanofibers of three different polymers (polyvinyl alcohol and polyvinylpyrrolidone with two different molar masses. Shelf life of the bacteria could be enhanced by the exclusion of water and by preparing a solid dosage form, which is an advantageous and patient-friendly way of administration. The formulations were stored at –20, 7 and 25°C, respectively. Viability testing showed that the nanofibers can provide long term stability for huge amounts of living bacteria if they are kept at (or below 7°C. Furthermore, all kinds of nanowebs prepared in this work dissolved instantly when they got in contact with water, thus the developed biohybrid nanowebs can provide new potential ways for curing bacterial vaginosis.

  3. Effects of maternal psychotropic drug dosage on birth outcomes

    Directory of Open Access Journals (Sweden)

    Michielsen LA

    2013-12-01

    Full Text Available Laura A Michielsen,1 Frank MMA van der Heijden,1 Paddy KC Janssen,2 Harold JH Kuijpers11Vincent van Gogh Institute for Psychiatry, Venlo, the Netherlands; 2Department of Pharmacy, VieCuri Medical Centre, Venlo, the NetherlandsBackground: The aim of this retrospective study was to explore the relationship between psychotropic medication dosage and birth outcomes.Methods: A total of 136 women were enrolled, who had an active mental disorder, were taking medication to prevent a relapse, or had a history of postpartum depression or psychosis. Medication use was evaluated for the three trimesters and during labor. Based on the defined daily dose, medication use was classified into three groups. Primary outcome variables included the infant gestational age at birth, birth weight, and Apgar scores at one and 5 minutes.Results: Our study showed a significantly higher incidence of Apgar score ≤7 at 5 minutes in women taking psychotropic drugs as compared with the group taking no medication, respectively (16.3% versus 0.0%, P=0.01. There was no significant difference between the two groups in Apgar score at one minute or in gestational age and birth weight. The results showed no significant differences in gestational age, birth weight, or Apgar scores for a low–intermediate or high dose of a selective serotonin reuptake inhibitor and for a low or intermediate dose of an antipsychotic.Conclusion: This study does not indicate a relationship between doses of selective serotonin reuptake inhibitors and antipsychotics and adverse neonatal outcomes.Keywords: pregnancy, psychotropic medication, dosage, birth outcomes

  4. Warfarin dosage response related pharmacogenetics in Chinese population.

    Directory of Open Access Journals (Sweden)

    Siyue Li

    Full Text Available As the most frequently prescribed anticoagulant, warfarin has large inter-individual variability in dosage. Genetic polymorphisms could largely explain the differences in dosage requirement. rs9923231 (VKORC1, rs7294 (VKORC1, rs1057910 (CYP2C9, rs2108622 (CYP4F2, and rs699664 (GGCX involved in the warfarin action mechanism and the circulatory vitamin K were selected to investigate their polymorphism characteristics and their effects on the pharmacodynamics and pharmacokinetics of warfarin in Chinese population.220 patients with cardiac valve replacement were recruited. International normalized ratio and plasma warfarin concentrations were determined. The five genetic polymorphisms were genotyping by pyro-sequencing. The relationships of maintenance dose, plasma warfarin concentration and INR were assessed among groups categorized by genotypes.rs9923231 and rs7294 in VKORC1 had the analogous genotype frequencies (D': 0.969. 158 of 220 recruited individuals had the target INR (1.5-2.5. Patients with AA of rs9923231 and CC of rs7294 required a significantly lower maintenance dose and plasma concentration than those with AG and TC, respectively. The mean weekly maintenance dose was also significantly lower in CYP2C9 rs1057910 mutated heterozygote than in patients with the wild homozygote. Eliminating the influence from environment factors (age, body weight and gender, rs9923231 and rs1057910 could explain about 32.0% of the variability in warfarin maintenance dose; rs7294 could explain 26.7% of the variability in plasma concentration. For patients with allele G of rs9923231 and allele T of rs7294, higher plasma concentration was needed to achieve the similar goal INR.A better understanding of the genetic variants in individuals can be the foundation of warfarin dosing algorithm and facilitate the reasonable and effective use of warfarin in Chinese.

  5. Integrating Anatomy Training into Radiation Oncology Residency: Considerations for Developing a Multidisciplinary, Interactive Learning Module for Adult Learners

    Science.gov (United States)

    Labranche, Leah; Johnson, Marjorie; Palma, David; D'Souza, Leah; Jaswal, Jasbir

    2015-01-01

    Radiation oncologists require an in-depth understanding of anatomical relationships for modern clinical practice, although most do not receive formal anatomy training during residency. To fulfill the need for instruction in relevant anatomy, a series of four multidisciplinary, interactive learning modules were developed for a cohort of radiation…

  6. Effectiveness of a Clinical Skills Workshop for drug-dosage calculation in a nursing program.

    Science.gov (United States)

    Grugnetti, Anna Maria; Bagnasco, Annamaria; Rosa, Francesca; Sasso, Loredana

    2014-04-01

    Mathematical and calculation skills are widely acknowledged as being key nursing competences if patients are to receive care that is both effective and safe. Indeed, weaknesses in mathematical competence may lead to the administration of miscalculated drug doses, which in turn may harm or endanger patients' lives. However, little attention has been given to identifying appropriate teaching and learning strategies that will effectively facilitate the development of these skills in nurses. One such approach may be simulation. To evaluate the effectiveness of a Clinical Skills Workshop on drug administration that focused on improving the drug-dosage calculation skills of second-year nursing students, with a view to promoting safety in drugs administration. A descriptive pre-post test design. Educational. Simulation center. The sample population included 77 nursing students from a Northern Italian University who attended a 30-hour Clinical Skills Workshop over a period of two weeks. The workshop covered integrated teaching strategies and innovative drug-calculation methodologies which have been described to improve psychomotor skills and build cognitive abilities through a greater understanding of mathematics linked to clinical practice. Study results showed a significant improvement between the pre- and the post-test phases, after the intervention. Pre-test scores ranged between 0 and 25 out of a maximum of 30 points, with a mean score of 15.96 (SD 4.85), and a median score of 17. Post-test scores ranged between 15 and 30 out of 30, with a mean score of 25.2 (SD 3.63) and a median score of 26 (pstudy shows that Clinical Skills Workshops may be tailored to include teaching techniques that encourage the development of drug-dosage calculation skills, and that training strategies implemented during a Clinical skills Workshop can enhance students' comprehension of mathematical calculations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Implementing and Integrating a Clinically-Driven Electronic Medical Record (EMR for Radiation Oncology in a Large Medical Enterprise

    Directory of Open Access Journals (Sweden)

    John Paxton Kirkpatrick

    2013-04-01

    Full Text Available Purpose/Objective: While our department is heavily invested in computer-based treatment planning, we historically relied on paper-based charts for management of Radiation Oncology patients. In early 2009, we initiated the process of conversion to an electronic medical record (EMR eliminating the need for paper charts. Key goals included the ability to readily access information wherever and whenever needed, without compromising safety, treatment quality, confidentiality or productivity.Methodology: In February, 2009, we formed a multi-disciplinary team of Radiation Oncology physicians, nurses, therapists, administrators, physicists/dosimetrists, and information technology (IT specialists, along with staff from the Duke Health System IT department. The team identified all existing processes and associated information/reports, established the framework for the EMR system and generated, tested and implemented specific EMR processes.Results: Two broad classes of information were identified: information which must be readily accessed by anyone in the health system versus that used solely within the Radiation Oncology department. Examples of the former are consultation reports, weekly treatment check notes and treatment summaries; the latter includes treatment plans, daily therapy records and quality assurance reports. To manage the former, we utilized the enterprise-wide system , which required an intensive effort to design and implement procedures to export information from Radiation Oncology into that system. To manage "Radiation Oncology" data, we used our existing system (ARIA, Varian Medical Systems. The ability to access both systems simultaneously from a single workstation (WS was essential, requiring new WS and modified software. As of January, 2010, all new treatments were managed solely with an EMR. We find that an EMR makes information more widely accessible and does not compromise patient safety, treatment quality or confidentiality

  8. Dosage of strontium 90 in human bone ashes; Dosage du strontium 90 sans les cendres d'os humain

    Energy Technology Data Exchange (ETDEWEB)

    Patti, F; Jeanmaire, L [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The determination of {sup 90}Sr in bones by dosage of its daughter product {sup 90}Y is a 4-step process: 1) elimination of the phosphate ions by precipitation of the Ca and Sr as oxalate in the presence of acid; 2) reduction in the calcium concentration to a suitable level by the addition of a known volume of nitric acid (a single precipitation is sufficient), the precipitation yield of the strontium nitrate is checked by the measurement of the amount of {sup 85}Sr added as tracer; 3) purification by a yttrium hydroxide precipitation; 4) extraction at equilibrium of the {sup 90}Y which is counted to give the concentration. By using 50 gm of ash it is possible to detect about 0.1 pCi of {sup 90}Sr per gram of calcium. The advantages of this technique: -) treatment of a large quantity of bone ash -) the use of a small volume of nitric acid (less than 2 ml/g of ash, and -) the various operations present no difficulty. (authors) [French] Determination du Sr dans les os par dosage de son produit de filiation {sup 90}Y. Principe du dosage: 1 - Eliminer les ions phosphates par precipitation du calcium et du strontium sous forme d'oxalate en milieu acide. 2 - Reduire la concentration en calcium a un niveau convenable par addition d'un volume determine d'acide nitrique (une seule precipitation est necessaire). Le rendement de precipitation du nitrate de strontium est controle par la mesure de {sup 85}Sr ajoute comme traceur. 3 - Purifier par une precipitation d'hydroxyde d'yttrium. 4 - Extraire a l'equilibre l'{sup 90}Y qui eat compte pour determiner le {sup 90}Sr. En traitant 50 g de cendre, il est possible de deceler de l'ordre de 0,1 pCi de {sup 90}Sr par gramme de calcium. Les 3 avantages de cette technique: 1 - traitement d'une quantite importante de cendres d'os, 2 - emploi d'un faible volume d'acide nitrique (moins de 2 ml/g de cendres), et 3 - les diverses operations ne presentent aucune difficulte.

  9. TaS2 nanosheet-based room-temperature dosage meter for nitric oxide

    Directory of Open Access Journals (Sweden)

    Qiyuan He

    2014-09-01

    Full Text Available A miniature dosage meter for toxic gas is developed based on TaS2 nanosheets, which is capable of indicating the toxic dosage of trace level NO at room temperature. The TaS2 film-based chemiresistor shows an irreversible current response against the exposure of NO. The unique non-recovery characteristic makes the TaS2 film-based device an ideal indicator of total dosage of chronicle exposure.

  10. Influence of radiative heat and mass transfer mechanism in system “water droplet-high-temperature gases” on integral characteristics of liquid evaporation

    Directory of Open Access Journals (Sweden)

    Glushkov Dmitrii O.

    2015-01-01

    Full Text Available Physical and mathematical (system of differential equations in private derivatives models of heat and mass transfer were developed to investigate the evaporation processes of water droplets and emulsions on its base moving in high-temperature (more than 1000 K gas flow. The model takes into account a conductive and radiative heat transfer in water droplet and also a convective, conductive and radiative heat exchange with high-temperature gas area. Water vapors characteristic temperature and concentration in small wall-adjacent area and trace of the droplet, numerical values of evaporation velocities at different surface temperature, the characteristic time of complete droplet evaporation were determined. Experiments for confidence estimation of calculated integral characteristics of processes under investigation - mass liquid evaporation velocities were conducted with use of cross-correlation recording video equipment. Their satisfactory fit (deviations of experimental and theoretical velocities were less than 15% was obtained. The influence of radiative heat and mass transfer mechanism on characteristics of endothermal phase transformations in a wide temperature variation range was established by comparison of obtained results of numerical simulation with known theoretical data for “diffusion” mechanisms of water droplets and other liquids evaporation in gas.

  11. Evaluation of insecticides in different dosages to control cicadas in parica plantations

    Directory of Open Access Journals (Sweden)

    Odineila Martins Monteiro

    2014-07-01

    Full Text Available This study aimed to determine the more efficient and economically viable dosage of chemical insecticide to control Quesada gigas (Hemiptera: Cicadidae nymphs in parica plantations. Three dosages of three products (carbofuran, imidacloprid and thiamethoxam were tested based on the maximum recommended dosage for the control of cicadas in coffee plants and applied in total area. The dosage of one kilogram of a commercial product based in thiamethoxam per hectare was more efficient economically and environmentally to control nymphs of Q. gigas in parica plantations.

  12. TH-C-17A-12: Integrated CBCT and Optical Tomography System On-Board a Small Animal Radiation Research Platform (SARRP)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K; Zhang, B; Eslami, S; Iordachita, I; Wong, J [Johns Hopkins University, Baltimore, MD (United States); Patterson, M [Hamilton Regional Cancer Ctr., Hamilton, ON (Canada)

    2014-06-15

    Purpose: We present a newly developed on-board optical tomography system for SARRP. Innovative features include the compact design and fast acquisition optical method to perform 3D soft tissue radiation guidance. Because of the on-board feature and the combination of the CBCT, diffusive optical tomography (DOT), bioluminescence and fluorescence tomography (BLT and FT), this integrated system is expected to provide more accurate soft tissue guidance than an off-line system as well as highly sensitive functional imaging in preclinical research. Methods: Images are acquired in the order of CBCT, DOT and then BLT/FT, where the SARRP CBCT and DOT are used to provide the anatomical and optical properties information to enhance the subsequent BLT/FT optical reconstruction. The SARRP stage is redesigned to include 9 imbedded optical fibers in contact with the animal's skin. These fibers, connected to a white light lamp or laser, serve as the light sources for the DOT or FT, respectively. A CCD camera with f/1.4 lens and multi-spectral filter set is used as the optical detector and is mounted on a portable cart ready to dock into the SARRP. No radiation is delivered during optical image acquisition. A 3-way mirror system capable of 180 degree rotation around the animal reflects the optical signal to the camera at multiple projection angles. A special black-painted dome covers the stage and provides the light shielding. Results: Spontaneous metastatic bioluminescent liver and lung tumor models will be used to validate the 3D BLT reconstruction. To demonstrate the capability of our FT system, GastroSense750 fluorescence agent will be used to imaging the mouse stomach and intestinal region in 3D. Conclusion: We expect that this integrated CBCT and optical tomography on-board a SARRP will present new research opportunities for pre-clinical radiation research. Supported by NCI RO1-CA 158100.

  13. TH-C-17A-12: Integrated CBCT and Optical Tomography System On-Board a Small Animal Radiation Research Platform (SARRP)

    International Nuclear Information System (INIS)

    Wang, K; Zhang, B; Eslami, S; Iordachita, I; Wong, J; Patterson, M

    2014-01-01

    Purpose: We present a newly developed on-board optical tomography system for SARRP. Innovative features include the compact design and fast acquisition optical method to perform 3D soft tissue radiation guidance. Because of the on-board feature and the combination of the CBCT, diffusive optical tomography (DOT), bioluminescence and fluorescence tomography (BLT and FT), this integrated system is expected to provide more accurate soft tissue guidance than an off-line system as well as highly sensitive functional imaging in preclinical research. Methods: Images are acquired in the order of CBCT, DOT and then BLT/FT, where the SARRP CBCT and DOT are used to provide the anatomical and optical properties information to enhance the subsequent BLT/FT optical reconstruction. The SARRP stage is redesigned to include 9 imbedded optical fibers in contact with the animal's skin. These fibers, connected to a white light lamp or laser, serve as the light sources for the DOT or FT, respectively. A CCD camera with f/1.4 lens and multi-spectral filter set is used as the optical detector and is mounted on a portable cart ready to dock into the SARRP. No radiation is delivered during optical image acquisition. A 3-way mirror system capable of 180 degree rotation around the animal reflects the optical signal to the camera at multiple projection angles. A special black-painted dome covers the stage and provides the light shielding. Results: Spontaneous metastatic bioluminescent liver and lung tumor models will be used to validate the 3D BLT reconstruction. To demonstrate the capability of our FT system, GastroSense750 fluorescence agent will be used to imaging the mouse stomach and intestinal region in 3D. Conclusion: We expect that this integrated CBCT and optical tomography on-board a SARRP will present new research opportunities for pre-clinical radiation research. Supported by NCI RO1-CA 158100

  14. Development and characterization of a gastroretentive dosage form composed of chitosan and hydroxyethyl cellulose for alendronate.

    Science.gov (United States)

    Chen, Ying-Chen; Ho, Hsiu-O; Chiu, Chiao-Chi; Sheu, Ming-Thau

    2014-01-01

    In this study, alendronate, the most commonly used biphosphonate for treating osteoporosis, was formulated as gastroretentive dosage form (GRDF) tablets to enhance its oral bioavailability. GRDF tablets were characterized with the effects of different molecular weights (MWs) of chitosan (CS) and hydroxyethyl cellulose (HEC) at various ratios on swelling, floating, and physical integrity. The CS component was formed using various acids: acetic, lactic, malic, succinic, and citric, and a high viscosity grade of HEC was selected. The results demonstrated that the swelling ratios of the formulations comprising high MW CS were lower than those of low or medium MW CS when salts were formed with any countering acids except for acetic acid. The decreasing ranking of the swelling rates was: CS-citrate > CS-malate > CS-lactate > CS-succinate > CS-acetate. A negative correlation was found between the pKa of the respective countering acid and the swelling rate. The swelling rate was promoted if an acidic salt of CS with a lower water content was incorporated, while it became slower when tablet hardness was higher or the compression force to form tablets was increased. Although HEC did not contribute to swelling or floating, it played a role in maintaining structural integrity. A prolonged dissolution profile of alendronate GRDF tablets developed in this study was observed.

  15. Many-integrated core (MIC) technology for accelerating Monte Carlo simulation of radiation transport: A study based on the code DPM

    Science.gov (United States)

    Rodriguez, M.; Brualla, L.

    2018-04-01

    Monte Carlo simulation of radiation transport is computationally demanding to obtain reasonably low statistical uncertainties of the estimated quantities. Therefore, it can benefit in a large extent from high-performance computing. This work is aimed at assessing the performance of the first generation of the many-integrated core architecture (MIC) Xeon Phi coprocessor with respect to that of a CPU consisting of a double 12-core Xeon processor in Monte Carlo simulation of coupled electron-photonshowers. The comparison was made twofold, first, through a suite of basic tests including parallel versions of the random number generators Mersenne Twister and a modified implementation of RANECU. These tests were addressed to establish a baseline comparison between both devices. Secondly, through the p DPM code developed in this work. p DPM is a parallel version of the Dose Planning Method (DPM) program for fast Monte Carlo simulation of radiation transport in voxelized geometries. A variety of techniques addressed to obtain a large scalability on the Xeon Phi were implemented in p DPM. Maximum scalabilities of 84 . 2 × and 107 . 5 × were obtained in the Xeon Phi for simulations of electron and photon beams, respectively. Nevertheless, in none of the tests involving radiation transport the Xeon Phi performed better than the CPU. The disadvantage of the Xeon Phi with respect to the CPU owes to the low performance of the single core of the former. A single core of the Xeon Phi was more than 10 times less efficient than a single core of the CPU for all radiation transport simulations.

  16. Low starting dosage of infliximab with possible escalating dosage in psoriatic arthritis gives the same treatment results as standard dosage of adalimumab or etanercept: results from the nationwide Icelandic ICEBIO registry

    Directory of Open Access Journals (Sweden)

    Gudbjornsson B

    2018-05-01

    Full Text Available Bjorn Gudbjornsson,1,2 Arni Jon Geirsson,3,4 Niels Steen Krogh5 1Centre for Rheumatology Research, University Hospital, Reykjavik, Iceland; 2Faculty of Medicine, University of Iceland, Reykjavik, Iceland; 3Department of Rheumatology, University Hospital, Reykjavik, Iceland; 4Laeknasetrid - Medical Clinic, University of Iceland, Reykjavik, Iceland; 5Zitelab Aps, Copenhagen, Denmark Objective: To explore differences in response to a low dosage regimen of infliximab with an escalating dosage in comparison to a standard dosage of etanercept and adalimumab in patients with psoriatic arthritis (PsA. Methods: Biologically naïve PsA patients who were beginning anti-TNF-α therapy were selected from the ICEBIO registry. Demographics and clinical differences were compared in four treatment groups: infliximab <4 mg/kg; infliximab >4 mg/kg; etanercept or adalimumab at baseline and on follow-up (6 and 12 months, last visit. The Kruskal–Wallis rank sum test was used for comparison of the groups and the Wilcoxon test to compare the two infliximab dosage regimens. Results: One hundred and eighty-five patients (61% female were identified; 84 patients received infliximab, 66 etanercept, and 35 adalimumab. A total of 19% of the patients treated with infliximab escalated their dosage ≥4 mg/kg. No significant differences were observed at baseline in respect to visual analog scale (VAS pain, VAS fatigue, Health Assessment Questionnaire, C-reactive protein (CRP, numbers of swollen or tender joints, or Disease Activity Score (DAS 28-CRP values. A similar treatment response was observed in all four treatment groups on follow-up. Conclusion: In respect to treatment effects, a low dosage of infliximab with possible escalating dosage is acceptable for the majority of PsA patients who are in need of biological treatment. Keywords: psoriatic arthritis, outcome, biological treatment, routine care, clinical nationwide registry

  17. Changing aspects of radiation enteropathy

    International Nuclear Information System (INIS)

    Morgenstern, L.; Hart, M.; Lugo, D.; Friedman, N.B.

    1985-01-01

    Fifty-two patients with radiation enteropathy secondary to radiation for abdominal or pelvic malignant neoplasms are described. This series (1977 to 1984) is compared with a series of 50 patients from the same institution over an earlier period (1961 to 1977). Intestinal obstruction was the principal complication in both series; 96% of the patients underwent either intestinal resection or anastomotic bypass of the affected segment. Changes that have occurred since the last report are as follows: changes in source of radiation energy (linear accelerator); less evidence of mucosal damage; increased serosal reaction (''serosal peel''); and increased use of elemental diets, parenteral nutrition, and long intestinal tubes in surgical management. Since postoperative radiation injury occurs most frequently in the pelvis, new developments for the exclusion of small bowel from the pelvis during radiation are reviewed. Changes in fractionation of radiation dosage should also be considered in patients with enteric symptoms during radiation therapy

  18. Current strategies for dosage reduction in computed tomography

    International Nuclear Information System (INIS)

    May, M.S.; Wuest, W.; Lell, M.M.; Uder, M.; Kalender, W.A.; Schmidt, B.

    2012-01-01

    The potential risks of radiation exposure associated with computed tomography (CT) imaging are reason for ongoing concern for both medical staff and patients. Radiation dose reduction is, according to the as low as reasonably achievable principle, an important issue in clinical routine, research and development. The complex interaction of preparation, examination and post-processing provides a high potential for optimization on the one hand but on the other a high risk for errors. The radiologist is responsible for the quality of the CT examination which requires specialized and up-to-date knowledge. Most of the techniques for radiation dose reduction are independent of the system and manufacturer. The basic principle should be radiation dose optimization without loss of diagnostic image quality rather than just reduction. (orig.) [de

  19. Dosage of boron traces in graphite, uranium and beryllium oxide; Dosage de traces de bore dans le graphite, l'uranium et l'oxyde de beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Coursier, J [Ecole Nationale Superieure de Physique et Chimie Industrielles, 75 - Paris (France); Hure, J; Platzer, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The problem of the dosage of the boron in the materials serving to the construction of nuclear reactors arises of the following way: to determine to about 0,1 ppm close to the quantities of boron of the order of tenth ppm. We have chosen the colorimetric analysis with curcumin as method of dosage. To reach the indicated contents, it is necessary to do a previous separation of the boron and the materials of basis, either by extraction of tetraphenylarsonium fluoborate in the case of the boron dosage in uranium and the beryllium oxide, either by the use of a cations exchanger resin of in the case of graphite. (M.B.) [French] Le probleme du dosage du bore dans les materiaux servant a la construction de reacteurs nucleaires se pose de la facon suivante: determiner a environ 0,1 ppm pres des quantites de bore de l'ordre de quelques dixiemes de ppm. Nous avons choisit la colorimetrie a la curcumine comme methode de dosage. Pour atteindre les teneurs indiquees, il est necessaire d'effectuer une separation prealable du bore et des materiaux de base, soit par extraction du fluoborate de tetraphenylarsonium dans le cas du dosage de bore dans l'uranium et l'oxyde de beryllium, soit par l'utilisation d'une resine echangeuse de cations dans le cas du graphite. (M.B.)

  20. Biowaiver monographs for immediate release solid oral dosage forms: piroxicam.

    Science.gov (United States)

    Shohin, Igor E; Kulinich, Julia I; Ramenskaya, Galina V; Abrahamsson, Bertil; Kopp, Sabine; Langguth, Peter; Polli, James E; Shah, Vinod P; Groot, D W; Barends, Dirk M; Dressman, Jennifer B

    2014-02-01

    Literature and experimental data relevant to the decision to allow a waiver of in vivo bioequivalence (BE) testing for the approval of immediate release (IR) solid oral dosage forms containing piroxicam in the free acid form are reviewed. Piroxicam solubility and permeability, its therapeutic use and therapeutic index, pharmacokinetic properties, data related to the possibility of excipient interactions and reported BE/bioavailability (BA), and corresponding dissolution data are taken into consideration. The available data suggest that according to the current biopharmaceutics classification system (BCS) and all current guidances, piroxicam would be assigned to BCS Class II. The extent of piroxicam absorption seems not to depend on manufacturing conditions or excipients, so the risk of bioinequivalence in terms of area under the curve (AUC) is very low, but the rate of absorption (i.e., BE in terms of Cmax ) can be affected by the formulation. Current in vitro dissolution methods may not always reflect differences in terms of Cmax for BCS Class II weak acids; however, minor differences in absorption rate of piroxicam would not subject the patient to unacceptable risks: as piroxicam products may be taken before or after meals, the rate of absorption cannot be considered crucial to drug action. Therefore, a biowaiver for IR piroxicam solid oral dosage form is considered feasible, provided that (a) the test product contains only excipients, which are also present in IR solid oral drug products containing piroxicam, which have been approved in ICH or associated countries, for instance, those presented in Table 3 of this paper; (b) both the test and comparator drug products dissolve 85% in 30 min or less at pH 1.2, 4.5, and 6.8; and (c) the test product and comparator show dissolution profile similarity in pH 1.2, 4.5, and 6.8. When not all of these conditions can be fulfilled, BE of the products should be established in vivo. © 2013 Wiley Periodicals, Inc. and the

  1. Solar Radiation and the UV Index: An Application of Numerical Integration, Trigonometric Functions, Online Education and the Modelling Process

    Science.gov (United States)

    Downs, Nathan; Parisi, Alfio V.; Galligan, Linda; Turner, Joanna; Amar, Abdurazaq; King, Rachel; Ultra, Filipina; Butler, Harry

    2016-01-01

    A short series of practical classroom mathematics activities employing the use of a large and publicly accessible scientific data set are presented for use by students in years 9 and 10. The activities introduce and build understanding of integral calculus and trigonometric functions through the presentation of practical problem solving that…

  2. Novel approach to the Helmholtz integral equation solution by Fourier series expansion for acoustic radiation and scattering problems

    CSIR Research Space (South Africa)

    Shatalov, MY

    2006-01-01

    Full Text Available -scale structure to guarantee the numerical accuracy of solution. In the present paper the authors propose to use a novel method of solution of the Helmholtz integral equation, which is based on expansion of the integrands in double Fourier series. The main...

  3. Response assessment of stereotactic body radiation therapy using dynamic contrast-enhanced integrated MR-PET in non-small cell lung cancer patients.

    Science.gov (United States)

    Huang, Yu-Sen; Chen, Jenny Ling-Yu; Hsu, Feng-Ming; Huang, Jei-Yie; Ko, Wei-Chun; Chen, Yi-Chang; Jaw, Fu-Shan; Yen, Ruoh-Fang; Chang, Yeun-Chung

    2018-01-01

    To evaluate the response in patients undergoing SBRT using dynamic contrast-enhanced (DCE) integrated magnetic resonance positron emission tomography (MR-PET). Stereotactic body radiation therapy (SBRT) is efficacious as a front-line local treatment for non-small cell lung cancer (NSCLC). We prospectively enrolled 19 lung tumors in 17 nonmetastatic NSCLC patients who were receiving SBRT as a primary treatment. They underwent DCE-integrated 3T MR-PET before and 6 weeks after SBRT. The following image parameters were analyzed: tumor size, standardized uptake value (SUV), apparent diffusion coefficient, K trans , k ep , v e , v p , and iAUC 60 . Chest computed tomography (CT) was performed at 3 months after SBRT. SBRT treatment led to tumor changes including significant decreases in the SUV max (-61%, P PET SUV max was correlated with the MR k ep mean (P = 0.002) and k ep SD (P 10 (P = 0.083). In patients with NSCLC who are receiving SBRT, DCE-integrated MR-PET can be used to evaluate the response after SBRT and to predict the local treatment outcome. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:191-199. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  5. Intensity Modulated Radiation Therapy With Simultaneous Integrated Boost in Patients With Brain Oligometastases: A Phase 1 Study (ISIDE-BM-1)

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Marica [Radiotherapy Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Chiesa, Silvia [Department of Radiotherapy, Fondazione Policlinico Universitario “A. Gemelli,” Catholic University of Sacred Heart, Rome (Italy); Macchia, Gabriella, E-mail: gmacchia@rm.unicatt.it [Radiotherapy Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Cilla, Savino [Medical Physics Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Bertini, Federica [Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Frezza, Giovanni [Radiotherapy Department, Ospedale Bellaria, Bologna (Italy); Farioli, Andrea [Department of Medical and Surgical Sciences, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Cammelli, Silvia [Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Balducci, Mario [Department of Radiotherapy, Fondazione Policlinico Universitario “A. Gemelli,” Catholic University of Sacred Heart, Rome (Italy); Ianiro, Anna [Medical Physics Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Angelini, Anna Lisa; Compagnone, Gaetano [Medical Physics Unit, S. Orsola-Malpighi Hospital, Bologna (Italy); and others

    2017-01-01

    Purpose: To investigate the maximum tolerated dose of intensity modulated radiation therapy simultaneous integrated boost whole-brain radiation therapy for palliative treatment of patients with <5 brain metastases using a standard linear accelerator. Materials and Methods: The whole brain plus 3-mm margin was defined as the planning target volume (PTV{sub wb}), whereas each brain metastasis, defined as the contrast-enhancing tumor on MRI T1 scans, plus a 3-mm isotropic margin, was defined as metastases PTV (PTV{sub m}). Radiation therapy was delivered in 10 daily fractions (2 weeks). Only the dose to PTV{sub m} was progressively increased in the patient cohorts (35 Gy, 40 Gy, 45 Gy, 50 Gy), whereas the PTV{sub wb} was always treated with 30 Gy (3 Gy per fraction) in all patients. The dose-limiting toxicity was evaluated providing that 3 months of follow-up had occurred after the treatment of a 6-patient cohort. Results: Thirty patients were enrolled in the study (dose PTV{sub m}: 35 Gy, 8 patients; 40 Gy, 6 patients; 45 Gy, 6 patients; 50 Gy, 10 patients). The number of treated brain metastases was 1 in 18 patients, 2 in 5 patients, 3 in 6 patients, and 4 in 1 patient. Three patients experienced dose-limiting toxicity: 1 patient at dose level 2 presented grade 3 (G3) skin toxicity; 1 patient at dose level 4 presented G3 neurologic toxicity; and 1 patient at the same level showed brain hemorrhage. Most patients showed G1 to 2 acute toxicity, in most cases skin (n=19) or neurologic (n=10). Twenty-seven were evaluable for response: 6 (22%) stable disease, 18 (67%) partial response, and 3 (11%) complete response. Median survival and 1-year overall survival were 12 months and 53%, respectively. No patient showed late toxicity. Conclusions: In this first prospective trial on the use of intensity modulated radiation therapy simultaneous integrated boost delivered with a standard linear accelerator in patients with brain oligometastases, a boost dose up to 50

  6. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    Science.gov (United States)

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. γ-ray radiation effect on properties of straw powder/PBS composite

    International Nuclear Information System (INIS)

    Yang Mingcheng; Luo Yongquan; Liu Wentao; Zhu Jun; Guo Dongquan; Li Zhaopeng; Gen Feng; Qu Lingbo

    2013-01-01

    Background: In recent years, with decreasing global fossil resources and increasing 'white pollution', renewable and biodegradable materials attract more and more attentions. Poly (butylene succinate) (PBS) has good mechanical property, biodegradability and processing performance, which is the focus of hot topics in the study of biodegradable plastic materials, however, being soft and of high cost, it is still limited in application range. Purpose: In order to improve the mechanical and thermal properties, a series of wheat straw powder/PBS composites were prepared by melt extrusion, and then the 60 Co-y ray was directly utilized to irradiate the straw powder/PBS composite. Methods: The influence of TAIC (triallyl isocyanurate) radiation absorbed dose and radiation sensitizer on the mechanical property and thermal performance of straw powder/PBS composite was investigated, and the impact fracture surface morphology of the composite was observed by SEM (scanning electron microscope). Results: The tensile strength and flexural strength were enhanced with increasing radiation dosage, and then tend to be stable, the heat distortion temperature also increased but not significantly with increasing radiation dosage. The results show that when TAIC content is 2%, with straw powder/PBS composite irradiated by 30-kGy dose, the tensile strength and flexural strength are increased by 26% and 39.8%, respectively. Conclusion: The radiation modification of composite material has no effect on thermal stability, but do improve the tensile strength and flexural strength when up to 2% of TAIC is integrated and irradiated by certain dose. The interface cohesiveness between straw powder and PBS is strengthened after radiation. (authors)

  8. Fumigant dosages below maximum label rate control some soilborne pathogens

    Directory of Open Access Journals (Sweden)

    Shachaf Triky-Dotan

    2016-08-01

    Full Text Available The activity of commercial soil fumigants on some key soilborne pathogens was assessed in sandy loam soil under controlled conditions. Seven soil fumigants that are registered in California or are being or have been considered for registration were used in this study: dimethyl disulfide (DMDS mixed with chloropicrin (Pic (79% DMDS and 21% Pic, Tri-Con (50% methyl bromide and 50% Pic, Midas Gold (33% methyl iodide [MI] and 67% Pic, Midas Bronze (50% MI and 50% Pic, Midas (MI, active ingredient [a.i.] 97.8%, Pic (a.i. 99% trichloronitromethane and Pic-Clor 60 (57% Pic and 37% 1,3-dichloropropene [1–3,D]. Dose-response models were calculated for pathogen mortality after 24 hours of exposure to fumigants. Overall, the tested fumigants achieved good efficacy with dosages below the maximum label rate against the tested pathogens. In this study, Pythium ultimum and citrus nematode were sensitive to all the fumigants and Verticillium dahliae was resistant. For most fumigants, California regulations restrict application rates to less than the maximum (federal label rate, meaning that it is possible that the fumigants may not control major plant pathogens. This research provides information on the effectiveness of these alternatives at these lower application rates. The results from this study will help growers optimize application rates for registered fumigants (such as Pic and 1,3-D and will help accelerate the adoption of new fumigants (such as DMDS if they are registered in California.

  9. Self-compacting concretes (SCC: comparison of methods of dosage

    Directory of Open Access Journals (Sweden)

    B. F. Tutikian

    Full Text Available The composition of a self-compacting concrete (SCC should be defined to fulfills a number of requirements, such as self-compactibility, strength and durability. This study aims to compare three methods of dosage for SCC with local materials, so as to determine which one is the most economical and rational, thus assisting the executor in making a decision and enabling economic and technical feasibility for its application. The methods used in the experimental program were: Nan Su et al., which was developed in 2001 [1]; Repette-Melo, which was proposed in 2005 [2]; and Tutikian & Dal Molin, which was developed in 2007 [3]. From the results obtained in the experimental program, it was observed that the method which presented the lowest cost and highest compressive strength at the ages of 7, 28 and 91 days was Tutikian & Dal Molin, while the one which reached the lowest chloride ion penetration, best compactness and highest elasticity modulus was Repette-Melo. In tests carried out in the fresh state, all tested methods yielded mixtures which comply with the self-compactibility levels required by ABNT NBR 15823:2010 [4].

  10. Dosage-dependent role of Rac1 in podocyte injury

    Science.gov (United States)

    Wan, Xiaoyang; Lee, Mi-Sun

    2016-01-01

    Activation of small GTPase Rac1 in podocytes is associated with rodent models of kidney injury and familial nephrotic syndrome. Induced Rac1 activation in podocytes in transgenic mice results in rapid transient proteinuria and foot process effacement, but not glomerular sclerosis. Thus it remains an open question whether abnormal activation of Rac1 in podocytes is sufficient to cause permanent podocyte damage. Using a number of transgenic zebrafish models, we showed that moderate elevation of Rac1 activity in podocytes did not impair the glomerular filtration barrier but aggravated metronidazole-induced podocyte injury, while inhibition of Rac1 activity ameliorated metronidazole-induced podocyte injury. Furthermore, a further increase in Rac1 activity in podocytes was sufficient to cause proteinuria and foot process effacement, which resulted in edema and lethality in juvenile zebrafish. We also found that activation of Rac1 in podocytes significantly downregulated the expression of nephrin and podocin, suggesting an adverse effect of Rac1 on slit diaphragm protein expression. Taken together, our data have demonstrated a causal link between excessive Rac1 activity and podocyte injury in a dosage-dependent manner, and transgenic zebrafish of variable Rac1 activities in podocytes may serve as useful animal models for the study of Rac1-related podocytopathy. PMID:26792065

  11. A step toward development of printable dosage forms for poorly soluble drugs

    DEFF Research Database (Denmark)

    Raijada, Dharaben Kaushikkumar; Genina, Natalja; Fors, Daniela

    2013-01-01

    The purpose of this study was to formulate printable dosage forms for a poorly soluble drug (piroxicam; PRX) and to gain understanding of critical parameters to be considered during development of such dosage forms. Liquid formulations of PRX were printed on edible paper using piezoelectric inkjet...

  12. 21 CFR 522.1662 - Oxytetracycline hydrochloride implantation or injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride implantation or injectable dosage forms. 522.1662 Section 522.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1662 Oxytetracycline hydrochloride implantation or injectable...

  13. Estimated Effect of Epoetin Dosage on Survival among Elderly Hemodialysis Patients in the United States

    OpenAIRE

    Zhang, Yi; Thamer, Mae; Cotter, Dennis; Kaufman, James; Hernán, Miguel A.

    2009-01-01

    Background and objectives: The common finding that low achieved hemoglobin in observational studies and high target hemoglobin in randomized trials each were associated with increased mortality and high epoetin dosage has suggested the possibility that high epoetin dosage might explain the increased mortality risk.

  14. Personal experience with whole-body, low-dosage, digital X-ray scanning (LODOX-Statscan in trauma

    Directory of Open Access Journals (Sweden)

    Zimmermann Heinz

    2009-09-01

    Full Text Available Abstract Background Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. Methods We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. Results and Conclusion The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm. The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.

  15. Simultaneous Integrated Boost–Intensity Modulated Radiation Therapy With Concomitant Capecitabine and Mitomycin C for Locally Advanced Anal Carcinoma: A Phase 1 Study

    Energy Technology Data Exchange (ETDEWEB)

    Deenen, Maarten J. [Division of Clinical Pharmacology, Department of Medical Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Dewit, Luc [Department of Radiotherapy, The Netherlands Cancer Institute, Amsterdam (Netherlands); Boot, Henk [Division of Gastroenterology and Hepatology, Department of Medical Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Beijnen, Jos H. [Department of Pharmacy and Pharmacology, Slotervaart Hospital, Amsterdam (Netherlands); Faculty of Science, Department of Pharmaceutical Sciences, Division of Pharmaco-epidemiology and Clinical Pharmacology, Utrecht University, Utrecht (Netherlands); Schellens, Jan H.M. [Division of Clinical Pharmacology, Department of Medical Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Faculty of Science, Department of Pharmaceutical Sciences, Division of Pharmaco-epidemiology and Clinical Pharmacology, Utrecht University, Utrecht (Netherlands); Cats, Annemieke, E-mail: a.cats@nki.nl [Division of Gastroenterology and Hepatology, Department of Medical Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2013-04-01

    Purpose: Newer radiation techniques, and the application of continuous 5-FU exposure during radiation therapy using oral capecitabine may improve the treatment of anal cancer. This phase 1, dose-finding study assessed the feasibility and efficacy of simultaneous integrated boost–intensity modulated radiation therapy (SIB-IMRT) with concomitant capecitabine and mitomycin C in locally advanced anal cancer, including pharmacokinetic and pharmacogenetic analyses. Methods and Materials: Patients with locally advanced anal carcinoma were treated with SIB-IMRT in 33 daily fractions of 1.8 Gy to the primary tumor and macroscopically involved lymph nodes and 33 fractions of 1.5 Gy electively to the bilateral iliac and inguinal lymph node areas. Patients received a sequential radiation boost dose of 3 × 1.8 Gy on macroscopic residual tumor if this was still present in week 5 of treatment. Mitomycin C 10 mg/m{sup 2} (maximum 15 mg) was administered intravenously on day 1, and capecitabine was given orally in a dose-escalated fashion (500-825 mg/m{sup 2} b.i.d.) on irradiation days, until dose-limiting toxicity emerged in ≥2 of maximally 6 patients. An additional 8 patients were treated at the maximum tolerated dose (MTD). Results: A total of 18 patients were included. The MTD of capecitabine was determined to be 825 mg/m{sup 2} b.i.d. The predominant acute grade ≥3 toxicities included radiation dermatitis (50%), fatigue (22%), and pain (6%). Fifteen patients (83% [95%-CI: 66%-101%]) achieved a complete response, and 3 (17%) patients a partial response. With a median follow-up of 28 months, none of the complete responders, and 2 partial responders had relapsed. Conclusions: SIB-IMRT with concomitant single dose mitomycin C and capecitabine 825 mg/m{sup 2} b.i.d. on irradiation days resulted in an acceptable safety profile, and proved to be a tolerable and effective treatment regimen for locally advanced anal cancer.

  16. Simultaneous Integrated Boost–Intensity Modulated Radiation Therapy With Concomitant Capecitabine and Mitomycin C for Locally Advanced Anal Carcinoma: A Phase 1 Study

    International Nuclear Information System (INIS)

    Deenen, Maarten J.; Dewit, Luc; Boot, Henk; Beijnen, Jos H.; Schellens, Jan H.M.; Cats, Annemieke

    2013-01-01

    Purpose: Newer radiation techniques, and the application of continuous 5-FU exposure during radiation therapy using oral capecitabine may improve the treatment of anal cancer. This phase 1, dose-finding study assessed the feasibility and efficacy of simultaneous integrated boost–intensity modulated radiation therapy (SIB-IMRT) with concomitant capecitabine and mitomycin C in locally advanced anal cancer, including pharmacokinetic and pharmacogenetic analyses. Methods and Materials: Patients with locally advanced anal carcinoma were treated with SIB-IMRT in 33 daily fractions of 1.8 Gy to the primary tumor and macroscopically involved lymph nodes and 33 fractions of 1.5 Gy electively to the bilateral iliac and inguinal lymph node areas. Patients received a sequential radiation boost dose of 3 × 1.8 Gy on macroscopic residual tumor if this was still present in week 5 of treatment. Mitomycin C 10 mg/m 2 (maximum 15 mg) was administered intravenously on day 1, and capecitabine was given orally in a dose-escalated fashion (500-825 mg/m 2 b.i.d.) on irradiation days, until dose-limiting toxicity emerged in ≥2 of maximally 6 patients. An additional 8 patients were treated at the maximum tolerated dose (MTD). Results: A total of 18 patients were included. The MTD of capecitabine was determined to be 825 mg/m 2 b.i.d. The predominant acute grade ≥3 toxicities included radiation dermatitis (50%), fatigue (22%), and pain (6%). Fifteen patients (83% [95%-CI: 66%-101%]) achieved a complete response, and 3 (17%) patients a partial response. With a median follow-up of 28 months, none of the complete responders, and 2 partial responders had relapsed. Conclusions: SIB-IMRT with concomitant single dose mitomycin C and capecitabine 825 mg/m 2 b.i.d. on irradiation days resulted in an acceptable safety profile, and proved to be a tolerable and effective treatment regimen for locally advanced anal cancer

  17. Effect of Radiation Dosage on Efficiency of Chloroplast Transfer by Protoplast Fusion in Nicotiana

    OpenAIRE

    Menczel, László; Galiba, Gábor; Nagy, Ferenc; Maliga, Pál

    1982-01-01

    Chloroplasts of Nicotiana tabacum SR1 were transferred into Nicotiana plumbaginifolia by protoplast fusion. The protoplasts of the organelle donor were irradiated with different lethal doses using a 60Co source, to facilitate the elimination of their nuclei from the fusion products. After fusion induction, clones derived from fusion products and containing streptomycin-resistant N. tabacum SR1 chloroplasts were selected by their ability to green on a selective medium. When N. tabacum protopla...

  18. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  19. Influence of radiation exposure rate on somatic mutation frequency and loss of reproductive integrity in tradescantia stamen hairs

    International Nuclear Information System (INIS)

    Ichikawa, S.; Nauman, C.H.; Sparrow, A.H.; Takahashi, C.S.

    1978-01-01

    Inflorescences of Tradescantia clone 02 (2n=12), hetero- or hemi-zygous for flower color, were exposed to a series of γ-ray exposures at two different exposure rates, 29.3 R/min and 0.026-0.52 R/min. Pink mutation-response curves, and survival curves based on reproductive integrity, were constructed for each of the exposure rates. Loss of reproductive integrity was also assessed at high (256 R/min) and low (0.52-4.17 R/min) γ-ray exposure rates in T. blossfeldiana (2n=72). All observations were made on stamen hairs. The higher exposure rate was 1.3-1.7 times more effective in inducing pink mutations in clone 02. A greater efficiency of the higher exposure rate was also found for both taxa at the loss of reproductive integrity endpoint. The D 0 values obtained at the higher exposure rates, 154 R for clone 02 and 720 R for T. blossfeldiana, were significantly lower than the corresponding values of 270 R and 1880 R obtained at the lower exposure rates. These D 0 's differ by factors of 1.75 and 2.61 for clone 02 and T. blossfeldiana, respectively. D 0 's for the two taxa were found to be inversely correlated with their interphase chromosome volumes. (Auth.)

  20. Alternative Manufacturing Concepts for Solid Oral Dosage Forms From Drug Nanosuspensions Using Fluid Dispensing and Forced Drying Technology.

    Science.gov (United States)

    Bonhoeffer, Bastian; Kwade, Arno; Juhnke, Michael

    2018-03-01

    Flexible manufacturing technologies for solid oral dosage forms with a continuous adjustability of the manufactured dose strength are of interest for applications in personalized medicine. This study explored the feasibility of using microvalve technology for the manufacturing of different solid oral dosage form concepts. Hard gelatin capsules filled with excipients, placebo tablets, and polymer films, placed in hard gelatin capsules after drying, were considered as substrates. For each concept, a basic understanding of relevant formulation parameters and their impact on dissolution behavior has been established. Suitable matrix formers, present either on the substrate or directly in the drug nanosuspension, proved to be essential to prevent nanoparticle agglomeration of the drug nanoparticles and to ensure a fast dissolution behavior. Furthermore, convection and radiation drying methods were investigated for the fast drying of drug nanosuspensions dispensed onto polymer films, which were then placed in hard gelatin capsules. Changes in morphology and in drug and matrix former distribution were observed for increasing drying intensity. However, even fast drying times below 1 min could be realized, while maintaining the nanoparticulate drug structure and a good dissolution behavior. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  1. In vivo reproducibility of robotic probe placement for an integrated US-CT image-guided radiation therapy system

    Science.gov (United States)

    Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John

    2014-03-01

    Radiation therapy is used to treat cancer by delivering high-dose radiation to a pre-defined target volume. Ultrasound (US) has the potential to provide real-time, image-guidance of radiation therapy to identify when a target moves outside of the treatment volume (e.g. due to breathing), but the associated probe-induced tissue deformation causes local anatomical deviations from the treatment plan. If the US probe is placed to achieve similar tissue deformations in the CT images required for treatment planning, its presence causes streak artifacts that will interfere with treatment planning calculations. To overcome these challenges, we propose robot-assisted placement of a real ultrasound probe, followed by probe removal and replacement with a geometrically-identical, CT-compatible model probe. This work is the first to investigate in vivo deformation reproducibility with the proposed approach. A dog's prostate, liver, and pancreas were each implanted with three 2.38-mm spherical metallic markers, and the US probe was placed to visualize the implanted markers in each organ. The real and model probes were automatically removed and returned to the same position (i.e. position control), and CT images were acquired with each probe placement. The model probe was also removed and returned with the same normal force measured with the real US probe (i.e. force control). Marker positions in CT images were analyzed to determine reproducibility, and a corollary reproducibility study was performed on ex vivo tissue. In vivo results indicate that tissue deformations with the real probe were repeatable under position control for the prostate, liver, and pancreas, with median 3D reproducibility of 0.3 mm, 0.3 mm, and 1.6 mm, respectively, compared to 0.6 mm for the ex vivo tissue. For the prostate, the mean 3D tissue displacement errors between the real and model probes were 0.2 mm under position control and 0.6 mm under force control, which are both within acceptable

  2. Integrating microRNA and mRNA expression profiles in response to radiation-induced injury in rat lung

    International Nuclear Information System (INIS)

    Xie, Ling; Zhou, Jundong; Zhang, Shuyu; Chen, Qing; Lai, Rensheng; Ding, Weiqun; Song, ChuanJun; Meng, XingJun; Wu, Jinchang

    2014-01-01

    Exposure to radiation provokes cellular responses, which are likely regulated by gene expression networks. MicroRNAs are small non-coding RNAs, which regulate gene expression by promoting mRNA degradation or inhibiting protein translation. The expression patterns of both mRNA and miRNA during the radiation-induced lung injury (RILI) remain less characterized and the role of miRNAs in the regulation of this process has not been studied. The present study sought to evaluate miRNA and mRNA expression profiles in the rat lung after irradiation. Male Wistar rats were subjected to single dose irradiation with 20 Gy using 6 MV x-rays to the right lung. (A dose rate of 5 Gy/min was applied). Rats were sacrificed at 3, 12 and 26 weeks after irradiation, and morphological changes in the lung were examined by haematoxylin and eosin. The miRNA and mRNA expression profiles were evaluated by microarrays and followed by quantitative RT-PCR analysis. A cDNA microarray analysis found 2183 transcripts being up-regulated and 2917 transcripts down-regulated (P ≤ 0.05, ≥2.0 fold change) in the lung tissues after irradiation. Likewise, a miRNAs microarray analysis indicated 15 miRNA species being up-regulated and 8 down-regulated (P ≤ 0.05). Subsequent bioinformatics anal -yses of the differentially expressed mRNA and miRNAs revealed that alterations in mRNA expression following irradiation were negatively correlated with miRNAs expression. Our results provide evidence indicating that irradiation induces alterations of mRNA and miRNA expression in rat lung and that there is a negative correlation of mRNA and miRNA expression levels after irradiation. These findings significantly advance our understanding of the regulatory mechanisms underlying the pathophysiology of radiation-induced lung injury. In summary, RILI does not develop gradually in a linear process. In fact, different cell types interact via cytokines in a very complex network. Furthermore, this study suggests that

  3. The Chernobyl Tissue Bank — A Repository for Biomaterial and Data Used in Integrative and Systems Biology Modeling the Human Response to Radiation

    Science.gov (United States)

    Thomas, Geraldine; Unger, Kristian; Krznaric, Marko; Galpine, Angela; Bethel, Jackie; Tomlinson, Christopher; Woodbridge, Mark; Butcher, Sarah

    2012-01-01

    The only unequivocal radiological effect of the Chernobyl accident on human health is the increase in thyroid cancer in those exposed in childhood or early adolescence. In response to the scientific interest in studying the molecular biology of thyroid cancer post Chernobyl, the Chernobyl Tissue Bank (CTB: www.chernobyltissuebank.com) was established in 1998. Thus far it is has collected biological samples from 3,861 individuals, and provided 27 research projects with 11,254 samples. The CTB was designed from its outset as a resource to promote the integration of research and clinical data to facilitate a systems biology approach to radiation related thyroid cancer. The project has therefore developed as a multidisciplinary collaboration between clinicians, dosimetrists, molecular biologists and bioinformaticians and serves as a paradigm for tissue banking in the omics era. PMID:24704918

  4. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Laser-induced extreme UV radiation sources for manufacturing next-generation integrated circuits

    Science.gov (United States)

    Borisov, V. M.; Vinokhodov, A. Yu; Ivanov, A. S.; Kiryukhin, Yu B.; Mishchenko, V. A.; Prokof'ev, A. V.; Khristoforov, O. B.

    2009-10-01

    The development of high-power discharge sources emitting in the 13.5±0.135-nm spectral band is of current interest because they are promising for applications in industrial EUV (extreme ultraviolet) lithography for manufacturing integrated circuits according to technological precision standards of 22 nm and smaller. The parameters of EUV sources based on a laser-induced discharge in tin vapours between rotating disc electrodes are investigated. The properties of the discharge initiation by laser radiation at different wavelengths are established and the laser pulse parameters providing the maximum energy characteristics of the EUV source are determined. The EUV source developed in the study emits an average power of 276 W in the 13.5±0.135-nm spectral band on conversion to the solid angle 2π sr in the stationary regime at a pulse repetition rate of 3000 Hz.

  5. Integrating radiation protection criteria for radioactive waste management into remediation procedures in existing exposure situations after a nuclear accident.

    Science.gov (United States)

    Sugiyama, Daisuke; Kimura, Hideo; Tachikawa, Hirokazu; Iimoto, Takeshi; Kawata, Yosuke; Ogino, Haruyuki; Okoshi, Minoru

    2018-03-01

    Experience after the accident at the Fukushima Daiichi nuclear power station has shown that there is a need to establish radiation protection criteria for radioactive waste management consistent with the criteria adopted for the remediation of existing exposure situations. A stepwise approach to setting such criteria is proposed. Initially, a reference level for the annual effective dose from waste management activities in the range 1-10 mSv should be set, with the reference level being less than the reference level for the ambient dose. Subsequently, the reference level for the annual effective dose from waste management activities should be reduced in one or more steps to achieve a final target value of 1 mSv. The dose criteria at each stage should be determined with relevant stakeholder involvement. Illustrative case studies show how this stepwise approach might be applied in practice.

  6. Integration of BOLD-fMRI and DTI into radiation treatment planning for high-grade gliomas located near the primary motor cortexes and corticospinal tracts

    International Nuclear Information System (INIS)

    Wang, Minglei; Ma, Hui; Wang, Xiaodong; Guo, Yanhong; Xia, Xinshe; Xia, Hechun; Guo, Yulin; Huang, Xueying; He, Hong; Jia, Xiaoxiong; Xie, Yan

    2015-01-01

    The main objective of this study was to evaluate the efficacy of integrating the blood oxygen level dependent functional magnetic resonance imaging (BOLD-fMRI) and diffusion tensor imaging (DTI) data into radiation treatment planning for high-grade gliomas located near the primary motor cortexes (PMCs) and corticospinal tracts (CSTs). A total of 20 patients with high-grade gliomas adjacent to PMCs and CSTs between 2012 and 2014 were recruited. The bilateral PMCs and CSTs were located in the normal regions without any overlapping with target volume of the lesions. BOLD-fMRI, DTI and conventional MRI were performed on patients (Karnofsky performance score ≥ 70) before radical radiotherapy treatment. Four different imaging studies were conducted in each patient: a planning computed tomography (CT), an anatomical MRI, a DTI and a BOLD-fMRI. For each case, three treatment plans (3DCRT, IMRT and IMRT-PMC&CST) were developed by 3 different physicists using the Pinnacle planning system. Our study has shown that there was no significant difference between the 3DCRT and IMRT plans in terms of dose homogeneity, but IMRT displayed better planning target volume (PTV) dose conformity. In addition, we have found that the Dmax and Dmean to the ipsilateral and contralateral PMC and CST regions were considerably decreased in IMRT-PMC&CST group (p < 0.001). In conclusion, integration of BOLD-fMRI and DTI into radiation treatment planning is feasible and beneficial. With the assistance of the above-described techniques, the bilateral PMCs and CSTs adjacent to the target volume could be clearly marked as OARs and spared during treatment

  7. NASA/GEWEX Surface Radiation Budget: Integrated Data Product With Reprocessed Radiance, Cloud, and Meteorology Inputs, and New Surface Albedo Treatment

    Science.gov (United States)

    Cox, Stephen J.; Stackhouse, Paul W., Jr.; Gupta, Shashi K.; Mikovitz, J. Colleen; Zhang, Taiping

    2016-01-01

    The NASA/GEWEX Surface Radiation Budget (SRB) project produces shortwave and longwave surface and top of atmosphere radiative fluxes for the 1983-near present time period. Spatial resolution is 1 degree. The current release 3.0 (available at gewex-srb.larc.nasa.gov) uses the International Satellite Cloud Climatology Project (ISCCP) DX product for pixel level radiance and cloud information. This product is subsampled to 30 km. ISCCP is currently recalibrating and recomputing their entire data series, to be released as the H product, at 10km resolution. The ninefold increase in pixel number will allow SRB a higher resolution gridded product (e.g. 0.5 degree), as well as the production of pixel-level fluxes. In addition to the input data improvements, several important algorithm improvements have been made. Most notable has been the adaptation of Angular Distribution Models (ADMs) from CERES to improve the initial calculation of shortwave TOA fluxes, from which the surface flux calculations follow. Other key input improvements include a detailed aerosol history using the Max Planck Institut Aerosol Climatology (MAC), temperature and moisture profiles from HIRS, and new topography, surface type, and snow/ice. Here we present results for the improved GEWEX Shortwave and Longwave algorithm (GSW and GLW) with new ISCCP data, the various other improved input data sets and the incorporation of many additional internal SRB model improvements. As of the time of abstract submission, results from 2007 have been produced with ISCCP H availability the limiting factor. More SRB data will be produced as ISCCP reprocessing continues. The SRB data produced will be released as part of the Release 4.0 Integrated Product, recognizing the interdependence of the radiative fluxes with other GEWEX products providing estimates of the Earth's global water and energy cycle (I.e., ISCCP, SeaFlux, LandFlux, NVAP, etc.).

  8. Radiation damages during synchrotron X-ray micro-analyses of Prussian blue and zinc white historic paintings: detection, mitigation and integration

    Energy Technology Data Exchange (ETDEWEB)

    Gervais, Claire [Bern University of the Arts, Bern (Switzerland); Thoury, Mathieu [IPANEMA, USR 3461 CNRS/MCC, Synchrotron SOLEIL, Gif-sur-Yvette (France); Reguer, Solenn; Gueriau, Pierre [Synchrotron SOLEIL, Gif-sur-Yvette (France); Mass, Jennifer [Winterthur Museum and Country Estate, Conservation Department, Winterthur, DE (United States)

    2015-11-15

    High-flux synchrotron techniques allow microspectroscopic analyses of artworks that were not feasible even a few years ago, allowing for a more detailed characterization of their constituent materials and a better understanding of their chemistry. However, interaction between high-flux photons and matter at the sub-microscale can generate damages which are not visually detectable. We show here different methodologies allowing to evidence the damages induced by microscopic X-ray absorption near-edge structure spectroscopy analysis (μXANES) at the Fe and Zn K-edges of a painting dating from the turn of the twentieth century containing Prussian blue and zinc white. No significant degradation of the pigments was noticed, in agreement with the excellent condition of the painting. However, synchrotron radiation damages occurred at several levels, from chemical changes of the binder, modification of crystal defects in zinc oxide, to Prussian blue photoreduction. They could be identified by using both the μXANES signal during analysis and with photoluminescence imaging in the deep ultraviolet and visible ranges after analysis. We show that recording accurately damaged areas is a key step to prevent misinterpretation of results during future re-examination of the sample. We conclude by proposing good practices that could help in integrating radiation damage avoidance into the analytical pathway. (orig.)

  9. Safety of dose escalation by simultaneous integrated boosting radiation dose within the primary tumor guided by 18FDG-PET/CT for esophageal cancer

    International Nuclear Information System (INIS)

    Yu, Wen; Cai, Xu-Wei; Liu, Qi; Zhu, Zheng-Fei; Feng, Wen; Zhang, Qin; Zhang, Ying-Jian; Yao, Zhi-Feng; Fu, Xiao-Long

    2015-01-01

    Purpose: To observe the safety of selective dose boost to the pre-treatment high 18 F-deoxyglucose (FDG) uptake areas of the esophageal GTV. Methods: Patients with esophageal squamous cell carcinoma were treated with escalating radiation dose of 4 levels, with a simultaneous integrated boost (SIB) to the pre-treatment 50% SUVmax area of the primary tumor. Patients received 4 monthly cycles of cisplatin and fluorouracil. Dose-limiting toxicity (DLT) was defined as any Grade 3 or higher acute toxicities causing continuous interruption of radiation for over 1 week. Results: From April 2012 to February 2014, dose has been escalated up to LEVEL 4 (70 Gy). All of the 25 patients finished the prescribed dose without DLT, and 10 of them developed Grade 3 acute esophagitis. One patient of LEVEL 2 died of esophageal hemorrhage within 1 month after completion of radiotherapy, which was not definitely correlated with treatment yet. Late toxicities remained under observation. With median follow up of 8.9 months, one-year overall survival and local control was 69.2% and 77.4%, respectively. Conclusions: Dose escalation in esophageal cancer based on 18 FDG-PET/CT has been safely achieved up to 70 Gy using the SIB technique. Acute toxicities were well tolerated, whereas late toxicities and long-term outcomes deserved further observation

  10. Preactivated thiolated nanoparticles: A novel mucoadhesive dosage form.

    Science.gov (United States)

    Menzel, Claudia; Bonengel, Sonja; Pereira de Sousa, Irene; Laffleur, Flavia; Prüfert, Felix; Bernkop-Schnürch, Andreas

    2016-01-30

    Within this study a novel form of mucoadhesive nanoparticles (NPs) exhibiting a prolonged residence time on mucosal tissues was developed. In order to achieve this goal a new thiomer was synthesized by the covalent attachment of the amino acid l-cysteine ethyl ester to poly(acrylic acid) (100 kDa). The free thiol groups were in the following preactivated with the aromatic thiol bearing ligand 2-mercaptonicotinic acid (2-MNA) and the amount of coupled l-cysteine ethyl ester as well as the amount of attached 2-MNA was determined. Based on this, preactivated thiomer NPs were prepared by ionic gelation with polyethylenimine (PEI). The resulting NPs were characterized regarding size and zeta potential. Furthermore their mucoadhesive properties were investigated via rheological measurements with porcine intestinal mucus and via determination of the particles' mucosal residence time. Results showed that 1666.74 μmol l-cysteine ethyl ester and 603.07 μmol 2-MNA could be attached per gram polymer. NPs were in a size range of 112.67-252.84 nm exhibiting a zeta potential of -29 mV. Thiolated NPs only led to a 2-fold increase in mucus viscosity whereas preactivated NPs showed a 6-fold higher mucus viscosity than unmodified NPs. The mucosal residence time of thiolated NPs was 1.6-fold prolonged and that of preactivated NPs even 4.4-fold higher compared to unmodified particles. Accordingly, preactivated thiolated NPs providing a prolonged residence time on mucosal membranes could be a promising dosage form for various applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Mathematical modeling of drug release from lipid dosage forms.

    Science.gov (United States)

    Siepmann, J; Siepmann, F

    2011-10-10

    Lipid dosage forms provide an interesting potential for controlled drug delivery. In contrast to frequently used poly(ester) based devices for parenteral administration, they do not lead to acidification upon degradation and potential drug inactivation, especially in the case of protein drugs and other acid-labile active agents. The aim of this article is to give an overview on the current state of the art of mathematical modeling of drug release from this type of advanced drug delivery systems. Empirical and semi-empirical models are described as well as mechanistic theories, considering diffusional mass transport, potentially limited drug solubility and the leaching of other, water-soluble excipients into the surrounding bulk fluid. Various practical examples are given, including lipid microparticles, beads and implants, which can successfully be used to control the release of an incorporated drug during periods ranging from a few hours up to several years. The great benefit of mechanistic mathematical theories is the possibility to quantitatively predict the effects of different formulation parameters and device dimensions on the resulting drug release kinetics. Thus, in silico simulations can significantly speed up product optimization. This is particularly useful if long release periods (e.g., several months) are targeted, since experimental trial-and-error studies are highly time-consuming in these cases. In the future it would be highly desirable to combine mechanistic theories with the quantitative description of the drug fate in vivo, ideally including the pharmacodynamic efficacy of the treatments. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Carboxymethyl starch mucoadhesive microspheres as gastroretentive dosage form.

    Science.gov (United States)

    Lemieux, Marc; Gosselin, Patrick; Mateescu, Mircea Alexandru

    2015-12-30

    Carboxymethyl starch microspheres (CMS-MS) were produced from carboxymethyl starch powder (CMS-P) with a degree of substitution (DS) from 0.1 to 1.5 in order to investigate the influence of DS on physicochemical, drug release and mucoadhesion properties as well as interactions with gastrointestinal tract (GIT) epithelial barrier models. Placebo and furosemide loaded CMS-MS were obtained by emulsion-crosslinking with sodium trimetaphosphate (STMP). DS had an impact on increasing equilibrium water uptake and modulating drug release properties of the CMS-MS according to the surrounding pH. The transepithelial electrical resistance (TEER) of NCI-N87 gastric cell monolayers was not influenced in presence of CMS-MS, whereas that of Caco-2 intestinal cell monolayers decreased with increasing DS but recovered initial values at about 15h post-treatment. CMS-MS with increasing DS also enhanced furosemide permeability across both NCI-N87 and Caco-2 monolayers at pH gradients from 3.0 to 7.4. Mucoadhesion of CMS-MS on gastric mucosa (acidic condition) increased with the DS up to 55% for a DS of 1.0 but decreased on neutral intestinal mucosa to less than 10% with DS of 0.1. The drug release, permeability enhancement and mucoadhesive properties of the CMS-MS suggest CMS-MS with DS between 0.6 and 1.0 as suitable excipient for gastroretentive oral delivery dosage forms. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Radiation decontamination of pharmaceutical raw materials as an integral part of the good pharmaceutical manufacturing practice (GPMP)

    Energy Technology Data Exchange (ETDEWEB)

    Razem, D; Katusin-Razem, B [Institut Rudjer Boskovic, Zagreb (Yugoslavia); Starcevic, M; Galekovic, B [PLIVA Pharmaceutical Works, Zagreb (Yugoslavia)

    1990-01-01

    The microbiological quality of many raw materials used in the manufacture of pharmaceuticals and adjuvants often fails to meet the standards set by the pharmaceutical industry. Raw materials of biological provenience are particularly susceptible to contamination. This work describes the present situation regarding the microbial load of corn starch. Given the accepted microbiological criteria, irradiation treatment is proposed as integral to Good Pharmaceutical Manufacturing Practice (GPMP). The use of total viable count as a guide for specifying microbial limits for non-sterile materials is supported. Criteria for the choice of dose are discussed. (author).

  14. Radiation decontamination of pharmaceutical raw materials as an integral part of the good pharmaceutical manufacturing practice (GPMP)

    International Nuclear Information System (INIS)

    Razem, D.; Katusin-Razem, B.; Starcevic, M.; Galekovic, B.

    1990-01-01

    The microbiological quality of many raw materials used in the manufacture of pharmaceuticals and adjuvants often fails to meet the standards set by the pharmaceutical industry. Raw materials of biological provenience are particularly susceptible to contamination. This work describes the present situation regarding the microbial load of corn starch. Given the accepted microbiological criteria, irradiation treatment is proposed as integral to Good Pharmaceutical Manufacturing Practice (GPMP). The use of total viable count as a guide for specifying microbial limits for non-sterile materials is supported. Criteria for the choice of dose are discussed. (author)

  15. Effects of gamma radiation and irradiated bean seeds on the dry bean weevil, Acanthoscelides obtectus say (Coleoptera: Bruchidae)

    International Nuclear Information System (INIS)

    Ignatowicz, S.; Brzostek, G.

    1988-01-01

    Low dosages of gamma radiation affected the development of immature stages of the bean weevil, Acanthoscelides obtectus Say. Radiosensitivity of the bean weevils decreased during their development, and adults seemed to be the most resistant stage for gamma radiation. There were no significant differences in mortality of immature stages of the pest during their development in beans treated with gamma radiation at dosages up to 1.06 kGy. Moreover, the females showed no ovipositional preference for untreated or irradiated beans

  16. Sterilization of Helicoverpa armigera (hubner) moth (lepidoptera; Noctudae) by using Gamma rays radiation

    International Nuclear Information System (INIS)

    Subiyakto; Wari D Astati; Sunarto Dwi A

    1998-01-01

    This experiment was conducted at the Radiation Facility, National Atomic Energy, Jakarta and Entomology Laboratory of the Research Institute for Tobacco and Crops Malang in 1991. Sterilization of moth by radiating insect on pupae stage. The dosage were 0 (unradiated), 1,3,5,7,9,11,13,and 15 krad. The treatments were arranged in complete randomized design with three replications. Each treatments were made variation of copulation (1) two females radiated with a make unradiated (2) two females unradiated with a male radiated, and (3) two females radiated with a male radiated. The results showed that sub sterile dosage (LD 50 ) for male was 0.94 krad and 7.02 krad for female. The sterile dosage (LD 95 ) for male was 10.85 krad and 14.35 krad for female. Research of the competition for copulation between the male radiated and unradiated is needed. (author)

  17. Application of DBNPA dosage for biofouling control in spiral wound membrane systems

    KAUST Repository

    Siddiqui, Amber

    2017-05-30

    Biocides may be used to control biofouling in spiral-wound reverse osmosis (RO) and nanofiltration (NF) systems. The objective of this study was to investigate the effect of biocide 2,2-dibromo-3-ni-trilopropionamide (DBNPA) dosage on biofouling control. Preventive biofouling control was studied applying a continuous dosage of substrate (0.5 mg/L) and DBNPA (1 mg/L). Curative biofouling control was studied on pre-grown biofilms, once again applying a continuous dosage of substrate (0.5 mg acetate C/L) and DBNPA (1 and 20 mg/L). Biofouling studies were performed in membrane fouling simulators (MFSs) supplied with biodegradable substrate and DBNPA. The pressure drop was monitored in time and at the end of the study, the accumulated biomass in MFS was quantified by adenosine triphosphate (ATP) and total organic carbon (TOC) analysis. Continuous dosage of DBNPA (1 mg/L) prevented pressure drop increase and biofilm accumulation in the MFSs during a run time of 7 d, showing that biofouling can be managed by preventive DBNPA dosage. For biofouled systems, continuous dosage of DBNPA (1 and 20 mg/L) inactivated the accumulated biomass but did not restore the original pressure drop and did not remove the accumulated inactive cells and extracellular polymeric substances (EPS), indicating DBNPA dosage is not suitable for curative biofouling control.

  18. Dosage sensitivity shapes the evolution of copy-number varied regions.

    Directory of Open Access Journals (Sweden)

    Benjamin Schuster-Böckler

    2010-03-01

    Full Text Available Dosage sensitivity is an important evolutionary force which impacts on gene dispensability and duplicability. The newly available data on human copy-number variation (CNV allow an analysis of the most recent and ongoing evolution. Provided that heterozygous gene deletions and duplications actually change gene dosage, we expect to observe negative selection against CNVs encompassing dosage sensitive genes. In this study, we make use of several sources of population genetic data to identify selection on structural variations of dosage sensitive genes. We show that CNVs can directly affect expression levels of contained genes. We find that genes encoding members of protein complexes exhibit limited expression variation and overlap significantly with a manually derived set of dosage sensitive genes. We show that complexes and other dosage sensitive genes are underrepresented in CNV regions, with a particular bias against frequent variations and duplications. These results suggest that dosage sensitivity is a significant force of negative selection on regions of copy-number variation.

  19. Radiation safety

    International Nuclear Information System (INIS)

    Van Riessen, A.

    2002-01-01

    Full text: Experience has shown that modem, fully enclosed, XRF and XRD units are generally safe. This experience may lead to complacency and ultimately a lowering of standards which may lead to accidents. Maintaining awareness of radiation safety issues is thus an important role for all radiation safety officers. With the ongoing progress in technology, a greater number of radiation workers are more likely to use a range of instruments/techniques - eg portable XRF, neutron beam analysis, and synchrotron radiation analysis. The source for each of these types of analyses is different and necessitates an understanding of the associated dangers as well as use of specific radiation badges. The trend of 'suitcase science' is resulting in scientists receiving doses from a range of instruments and facilities with no coordinated approach to obtain an integrated dose reading for an individual. This aspect of radiation safety needs urgent attention. Within Australia a divide is springing up between those who work on Commonwealth property and those who work on State property. For example a university staff member may operate irradiating equipment on a University campus and then go to a CSIRO laboratory to operate similar equipment. While at the University State regulations apply and while at CSIRO Commonwealth regulations apply. Does this individual require two badges? Is there a need to obtain two licences? The application of two sets of regulations causes unnecessary confusion and increases the workload of radiation safety officers. Radiation safety officers need to introduce risk management strategies to ensure that both existing and new procedures result in risk minimisation. A component of this strategy includes ongoing education and revising of regulations. AXAA may choose to contribute to both of these activities as a service to its members as well as raising the level of radiation safety for all radiation workers. Copyright (2002) Australian X-ray Analytical

  20. Radiation exposure during ureteroscopy

    International Nuclear Information System (INIS)

    Bagley, D.H.; Cubler-Goodman, A.

    1990-01-01

    Use of fluoroscopy during ureteroscopy increases the risk of radiation exposure to the urologist and patient. Radiation entrance dosages were measured at skin level in 37 patients, and at the neck, trunk and finger of the urologist, and neck and trunk of the circulating nurse. Radiation exposure time was measured in 79 patients, and was related to the purpose of the procedure and the type of ureteroscope used, whether rigid or flexible. Exposure could be minimized by decreasing the fluoroscopy time. A portable C-arm fluoroscopy unit with electronic imaging and last image hold mode should be used to minimize exposure time. Lead aprons and thyroid shields should be used by the urologist and other personnel in the endoscopy room

  1. Effective gamma radiation dose for rice genetic improvement by means of mutation radioinduction in Cuba

    International Nuclear Information System (INIS)

    Perez Talavera, S.; Labrada Remon, A.; Gonzalez, L.M.

    1993-01-01

    Determination of the useful radiation dosages for its employment in rice breeding in Cuban conditions was made; for this the radio sensibility of three commercial rice varieties was investigated using plant height in laboratory condition as criterion

  2. Boxing and mixed martial arts: preliminary traumatic neuromechanical injury risk analyses from laboratory impact dosage data.

    Science.gov (United States)

    Bartsch, Adam J; Benzel, Edward C; Miele, Vincent J; Morr, Douglas R; Prakash, Vikas

    2012-05-01

    In spite of ample literature pointing to rotational and combined impact dosage being key contributors to head and neck injury, boxing and mixed martial arts (MMA) padding is still designed to primarily reduce cranium linear acceleration. The objects of this study were to quantify preliminary linear and rotational head impact dosage for selected boxing and MMA padding in response to hook punches; compute theoretical skull, brain, and neck injury risk metrics; and statistically compare the protective effect of various glove and head padding conditions. An instrumented Hybrid III 50th percentile anthropomorphic test device (ATD) was struck in 54 pendulum impacts replicating hook punches at low (27-29 J) and high (54-58 J) energy. Five padding combinations were examined: unpadded (control), MMA glove-unpadded head, boxing glove-unpadded head, unpadded pendulum-boxing headgear, and boxing glove-boxing headgear. A total of 17 injury risk parameters were measured or calculated. All padding conditions reduced linear impact dosage. Other parameters significantly decreased, significantly increased, or were unaffected depending on padding condition. Of real-world conditions (MMA glove-bare head, boxing glove-bare head, and boxing glove-headgear), the boxing glove-headgear condition showed the most meaningful reduction in most of the parameters. In equivalent impacts, the MMA glove-bare head condition induced higher rotational dosage than the boxing glove-bare head condition. Finite element analysis indicated a risk of brain strain injury in spite of significant reduction of linear impact dosage. In the replicated hook punch impacts, all padding conditions reduced linear but not rotational impact dosage. Head and neck dosage theoretically accumulates fastest in MMA and boxing bouts without use of protective headgear. The boxing glove-headgear condition provided the best overall reduction in impact dosage. More work is needed to develop improved protective padding to minimize

  3. General Requirements to the Preparation of Tinctures, Decoctions. Dosage of Phytopreparations

    Directory of Open Access Journals (Sweden)

    I.B. Yershovа

    2016-09-01

    Full Text Available The article describes the advantages and disadvantages of using herbal medicine, general information for the collection of medicinal plants. According to the World Health Organization, the classification of herbal medicine is an integral part of traditional medicine. It refers to the variety of metabolic therapy. This treatment meets the requirements of pathogenetic therapy. Currently, more than 30 % of medicines on the pharmaceutical market have herbal origin. According to the World Health Organization, about 80 % of the world population use mainly traditional medicines of natural origin within the framework of primary health care system. Analysis of publications on phytotherapy revealed insufficient coverage of contraindications and side effects of certain plants. This was the basis for opening in our magazine this column, and we wanted to start with what would be the advantages and disadvantages of phytotherapy. Benefits of herbal medi­cine: biological proximity of the active substances of plants and active substances of the body, harmony therapy for the human body, the prolonged effect of herbal medicines after the completion of therapy, the opportunity to prepare a wide variety of different dosage forms, for both indoor and outdoor use, compatibility with many synthetic pharmaceuticals drugs, comprehensive multilateral action of plants, no side effects, simplicity and ease of preparation of herbal remedies at home, the availability for the majority of patients due to the low cost of the medicines. Limitations of herbal medicine: the complexity of the standardization of the treatment effect of herbal drugs, the complexity of establishing a dose, selectivity of diseases, in which typical herbal remedies are prescribed, the risk of poisoning, particularly in self-collection of medicinal plants. The article also provides methods for the preparation of various forms of herbal remedies, dosage for adults and children. With all the advantages of

  4. Monitoring of radiation via CT

    International Nuclear Information System (INIS)

    Atzinger, A.; Pfaendner, K.; Gfirtner, H.; Hoetzinger, H.

    1981-01-01

    The results presented in this article lead to the conclusion that it would be appropriate to demand control or monitoring of radiation via CT whenever complicated exposure to radiation is required. Such control appears mandatory in order to guarantee a sufficiently high tumour dosage and satisfactory protection or minimum burdening of the surrounding tissue. At first sight, it may seem that such CT operations are relatively costly. However, once the teamwork has been properly established, both the time required and the cost involved remain within reasonable limits and will probably not be greater than control via therapy simulator. The decisive factor is that computerised tomography should offer sufficient possibilities of translating such control into reality by effecting the necessary dosage adjustments in accordance with given requirements. (orig.) [de

  5. Impact of radiation embrittlement on integrity of pressure vessel supports for two PWR [pressurized-water-reactor] plants

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Pennell, W.E.; Robinson, G.C.; Nanstad, R.K.

    1988-01-01

    Recent pressure-vessel surveillance data from the High Flux Isotope Reactor (HFIR) indicate an embrittlement fluence-rate effect that is applicable to the evaluation of the integrity of light-water reactor (LWR) pressure vessel supports. A preliminary evaluation using the HFIR data indicated increases in the nil ductility transition temperature at 32 effective full-power years (EFPY) of 100 to 130/degree/C for pressurized-water-reactor (PWR) vessel supports located in the cavity at midheight of the core. This result indicated a potential problem with regard to life expectancy. However, an accurate assessment required a detailed, specific-plant, fracture-mechanics analysis. After a survey and cursory evaluation of all LWR plants, two PWR plants that appeared to have a potential problem were selected. Results of the analyses indicate minimum critical flaw sizes small enough to be of concern before 32 EFPY. 24 refs., 16 figs., 7 tabs

  6. Dissecting plant chromosomes by the use of ionizing radiation

    Science.gov (United States)

    Radiation treatment of genomes is used to generate chromosome breaks for numerous applications. This protocol describes the preparation of seeds and the determination of the optimal level of irradiation dosage for the creation of a radiation hybrid (RH) population. These RH lines can be used to gene...

  7. Pavor nocturnus: a complication of single daily tricyclic or neuroleptic dosage.

    Science.gov (United States)

    Flemenbaum, A

    1976-05-01

    The author tested the hypothesis that a single bedtime dosage schedule of tricyclic or neuroleptic medication produces increased frequency of night terrors by administering a questionnaire to 30 medical patients who were not receiving such medications and 100 psychiatric patients on either multiple- or single-dosage schedules. Psychiatric patients on multiple-dosage schedules reported no more frightening dreams than the medical patients, whereas almost three-fourths of those receiving single bedtime doses had frightening dreams, a significant difference from the medical sample. This preliminary report is presented to call attention to the possible undesirable effects of a single dose schedule.

  8. Spacecraft radiator systems

    Science.gov (United States)

    Anderson, Grant A. (Inventor)

    2012-01-01

    A spacecraft radiator system designed to provide structural support to the spacecraft. Structural support is provided by the geometric "crescent" form of the panels of the spacecraft radiator. This integration of radiator and structural support provides spacecraft with a semi-monocoque design.

  9. High-dosage dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    Mehta, K.

    1999-01-01

    The high-dose dosimetry programme was initiated by the International Atomic Energy Agency in 1977. Like any other Agency programme, this one has various activities. These cover: research contracts and research agreements, co-ordinated research projects (CRP), training courses, and laboratory-based activities. The Agency's dose quality audit service (International Dose Assurance Service, IDAS), initiated in 1985, is one of the key elements of the programme. At earlier times, the technical part was operated through a laboratory in Germany. However, after purchasing the Bruker ESR spectrometer, the entire service has been operated from the Agency since 1992. This audit service has served well the needs of various institutes around the world involved with radiation processing. We have had two Co-ordinated Research Projects (the second one is in its last year) over the last several years. Both were/are aimed at standardization of dosimetry for radiation processing. Nine or ten participants of each CRP were about evenly distributed between the developed and developing Member States. In collaboration with the Food and Environmental Protection Section and the Industrial Applications and Chemistry Section, the Dosimetry and Medical Radiation Physics Section has participated in several training courses; these have been mainly regional courses. This collaboration has worked well since such courses combine specific radiation processing applications with the needs of good dosimetry and process control. Also, the Agency has organised several dose intercomparisons in recent time. The activities of the high-dose dosimetry programme since the last symposium (November 1990) are reviewed here. (author)

  10. Influence of dosage form on the intravitreal pharmacokinetics of diclofenac.

    Science.gov (United States)

    Durairaj, Chandrasekar; Kim, Stephen J; Edelhauser, Henry F; Shah, Jaymin C; Kompella, Uday B

    2009-10-01

    To prepare a suspension form of diclofenac and compare the influence of the injected form (suspension versus solution) on the intravitreal pharmacokinetics of diclofenac in Dutch belted pigmented rabbits. Diclofenac acid was prepared and characterized in a suspension formulation. Rabbit eyes were injected with either diclofenac sodium solution (0.3 mg) or diclofenac acid suspension (10 mg) prepared in 0.1 mL balanced salt solution. Rabbits were killed at regular time intervals, the eyes enucleated, and drug content quantified in the vitreous humor and retina-choroid tissue by high-performance liquid chromatography. Pharmacokinetic models were developed for both the dosage forms, and simulations were performed for different doses. Diclofenac acid with an approximate 5-mum particle size exhibited 3.5-fold lower solubility in vitreous humor, when compared with its sodium salt. The estimated settling velocity of the suspension in the vitreous humor was 3 cm/h. After diclofenac sodium salt solution injection, drug levels declined rapidly with no drug levels detectable after 24 hours in the vitreous humor and 4 hours in the RC. Throughout the assessed time course, drug levels were higher in the vitreous. However, sustained, high drug levels were observed in both the vitreous humor and the retina-choroid even on day 21 after diclofenac acid suspension injection, with retina-choroid drug levels being higher beginning at 0.25 hour. The elimination half-life of diclofenac suspension was 24 and 18 days in vitreous and retina-choroid, respectively, compared to 2.9 and 0.9 hours observed with diclofenac sodium. The pharmacokinetic models developed indicated a slow-release distribution or depot compartment for the diclofenac acid suspension in the posterior segment. Simulations indicated the inability of a 10-mg dose of diclofenac sodium solution to sustain drug levels in the vitreous beyond 11 days. By choosing a less soluble form of a drug such as diclofenac acid, vitreous

  11. LDRD Final Report - Investigations of the impact of the process integration of deposited magnetic films for magnetic memory technologies on radiation hardened CMOS devices and circuits - LDRD Project (FY99)

    International Nuclear Information System (INIS)

    Myers, David R.; Jessing, Jeffrey R.; Spahn, Olga B.; Shaneyfelt, Marty R.

    2000-01-01

    This project represented a coordinated LLNL-SNL collaboration to investigate the feasibility of developing radiation-hardened magnetic non-volatile memories using giant magnetoresistance (GMR) materials. The intent of this limited-duration study was to investigate whether giant magnetoresistance (GMR) materials similar to those used for magnetic tunnel junctions (MTJs) were process compatible with functioning CMOS circuits. Sandia's work on this project demonstrated that deposition of GMR materials did not affect the operation nor the radiation hardness of Sandia's rad-hard CMOS technology, nor did the integration of GMR materials and exposure to ionizing radiation affect the magnetic properties of the GMR films. Thus, following deposition of GMR films on rad-hard integrated circuits, both the circuits and the films survived ionizing radiation levels consistent with DOE mission requirements. Furthermore, Sandia developed techniques to pattern deposited GMR films without degrading the completed integrated circuits upon which they were deposited. The present feasibility study demonstrated all the necessary processing elements to allow fabrication of the non-volatile memory elements onto an existing CMOS chip, and even allow the use of embedded (on-chip) non-volatile memories for system-on-a-chip applications, even in demanding radiation environments. However, funding agencies DTRA, AIM, and DARPA did not have any funds available to support the required follow-on technology development projects that would have been required to develop functioning prototype circuits, nor were such funds available from LDRD nor from other DOE program funds

  12. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S

    2015-01-01

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  13. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Chung, E; Hess, C; Stern, R; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  14. Change of notch impact strength depending on radiation dose and test temperature

    Directory of Open Access Journals (Sweden)

    Martin Bednarik

    2017-01-01

    Full Text Available The main purpose of this paper has been determine the effect of radiation crosslinking on the notch impact strength of polyamides filled with fiberglass. These properties were examined in dependence on the dosage of the ionizing beta radiation (non-irradiated samples and those irradiated by dosage 66 and 132 kGy were compared and on the test temperature (23–150 °C.

  15. Continuous intravenous infusion of ampicillin and gentamicin during parenteral nutrition to 36 newborn infants using a dosage schedule

    DEFF Research Database (Denmark)

    Colding, H; Møller, S; Andersen, G E

    1984-01-01

    Ampicillin and gentamicin were given continuously i.v. to 36 newborn infants using a dosage schedule and the results were compared with those obtained in an earlier study including 88 infants who received individually calculated dosages. With the dosage schedule the variation in the serum concent...

  16. Integrated effect of gamma radiation and biocontrol agent on quality parameters of apple fruit: An innovative commercial preservation method

    Science.gov (United States)

    Ahari Mostafavi, Hossein; Mahyar Mirmajlessi, Seyed; Fathollahi, Hadi; Shahbazi, Samira; Mohammad Mirjalili, Seyed

    2013-10-01

    Effects of gamma irradiation and biocontrol agent (Pseudomonas fluorescens) on the physico-chemical parameters (including moisture, total soluble solids, antioxidant activity, phenolic content and firmness) of cv. Golden Delicious apples were investigated for their ability to avoid the post-harvest blue mold caused by Penicillium expansum during cold storage. Freshly harvested apples were inoculated with P. expansum. Treated fruits were irradiated at doses of 0, 200, 400, 600 and 800 Gy and then inoculated with P. fluorescens suspension. Samples were evaluated at 3 month intervals. The results demonstrated a clear link between antioxidant activity and phenolic content, so that dose range of 200-400 Gy significantly increased phenolic content and antioxidant activity. Effect of P. fluorescens was similar to irradiation at 200 and 400 Gy that could prevent lesion diameter in pathogen-treated apples. As dose and storage time increased firmness decreased but, combination of P. fluorescens as well as irradiation (at 200-400 Gy) could decrease softening apple fruits during storage. In all parameters, P. fluorescens (as biocontrol agent) inhibited P. expansum similar to irradiation at 200-400 Gy. So, integrated treatment of irradiation and biocontrol agent explored the potential dual benefit of low doses (200 and 400 Gy) as a suitable method to sustain physico-chemical quality and conclusively reduce apple fruits losses during post-harvest preservation.

  17. Stability of Dosage Forms in the Pharmaceutical Payload Aboard Space Missions

    Science.gov (United States)

    Du, Brian J.; Daniels, Vernie; Boyd, Jason L.; Crady, Camille; Satterfield, Rick; Younker, Diane R.; Putcha, Lakshmi

    2009-01-01

    Efficacious pharmaceuticals with adequate shelf lives are essential for successful space medical operations. Stability of pharmaceuticals, therefore, is of paramount importance for assuring the health and wellness of astronauts on future space exploration missions. Unique physical and environmental factors of space missions may contribute to the instability of pharmaceuticals, e.g., radiation, humidity and temperature variations. Degradation of pharmaceutical formulations can result in inadequate efficacy and/or untoward toxic effects, which could compromise astronaut safety and health. Methods: Four identical pharmaceutical payload kits containing 31 medications in different dosage forms (liquid, tablet, capsule, ointment and suppository) were transported to the International Space Station aboard the Space Shuttle (STS-121). One of the 4 kits was stored on the Shuttle and the other 3 were stored on the International Space Station (ISS) for return to Earth at 6-month interval aboard a pre-designated Shuttle flight for each kit. The kit stored on the Shuttle was returned to Earth aboard STS-121 and 2 kits from ISS were returned on STS 117 and STS-122. Results: Analysis of standard physical and chemical parameters of degradation was completed for pharmaceuticals returned by STS-121 after14 days, STS - 117 after11 months and STS 122 after 19 months storage aboard ISS. Analysis of all flight samples along with ground-based matching controls was completed and results were compiled. Conclusion: Evaluation of results from the shuttle (1) and ISS increments (2) indicate that the number of formulations degraded in space increased with duration of storage in space and was higher in space compared to their ground-based counterparts. Rate of degradation for some of the formulations tested was faster in space than on Earth. Additionally, some of the formulations included in the medical kits were unstable, more so in space than on the ground. These results indicate that the

  18. Tissue- and stage-dependent dosage compensation on the Neo-X chromosome in drosophila pseudoobscura

    KAUST Repository

    Nozawa, Masafumi; Fukuda, Nana; Ikeo, Kazuho; Gojobori, Takashi

    2013-01-01

    Sex chromosome dosage compensation (DC) is widely accepted in various organisms. This concept is mostly supported by comparisons of gene expression between chromosomes and between sexes. However, genes on the X chromosome and autosomes are mostly

  19. 76 FR 81806 - Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution

    Science.gov (United States)

    2011-12-29

    .... FDA-2011-N-0003] Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution... solution of ivermectin. DATES: This rule is effective December 29, 2011. FOR FURTHER INFORMATION CONTACT... ANADA 200-318 for [[Page 81807

  20. Meta-analysis : High-dosage vitamin E supplementation may increase all-cause mortality

    NARCIS (Netherlands)

    Miller, ER; Pastor-Barriuso, R; Dalal, D; Riemersma, RA; Appel, LJ; Guallar, E

    2005-01-01

    Background: Experimental models and observational studies suggest that vitamin E supplementation may prevent cardiovascular disease and cancer. However, several trials of high-dosage vitamin E supplementation showed non-statistically significant increases in total mortality. Purpose: To perform a

  1. Biowaiver Monographs for Immediate Release Solid Oral Dosage Forms: Proguanil Hydrochloride.

    NARCIS (Netherlands)

    Plöger, Gerlinde F; Abrahamsson, Bertil; Cristofoletti, Rodrigo; Groot, D I R K W; Langguth, Peter; Mehta, Mehul U; Parr, Alan; Polli, James E; Shah, Vinod P; Tajiri, Tomokazu; Dressman, Jennifer B

    2018-01-01

    Literature data relevant to the decision to waive in vivo bioequivalence testing for the approval of generic immediate release solid oral dosage forms of proguanil hydrochloride are reviewed. To clarify the Biopharmaceutics Classification System (BCS) classification, experimental solubility and

  2. Integration of Chandrasekhar's integral equation

    International Nuclear Information System (INIS)

    Tanaka, Tasuku

    2003-01-01

    We solve Chandrasekhar's integration equation for radiative transfer in the plane-parallel atmosphere by iterative integration. The primary thrust in radiative transfer has been to solve the forward problem, i.e., to evaluate the radiance, given the optical thickness and the scattering phase function. In the area of satellite remote sensing, our problem is the inverse problem: to retrieve the surface reflectance and the optical thickness of the atmosphere from the radiance measured by satellites. In order to retrieve the optical thickness and the surface reflectance from the radiance at the top-of-the atmosphere (TOA), we should express the radiance at TOA 'explicitly' in the optical thickness and the surface reflectance. Chandrasekhar formalized radiative transfer in the plane-parallel atmosphere in a simultaneous integral equation, and he obtained the second approximation. Since then no higher approximation has been reported. In this paper, we obtain the third approximation of the scattering function. We integrate functions derived from the second approximation in the integral interval from 1 to ∞ of the inverse of the cos of zenith angles. We can obtain the indefinite integral rather easily in the form of a series expansion. However, the integrals at the upper limit, ∞, are not yet known to us. We can assess the converged values of those series expansions at ∞ through calculus. For integration, we choose coupling pairs to avoid unnecessary terms in the outcome of integral and discover that the simultaneous integral equation can be deduced to the mere integral equation. Through algebraic calculation, we obtain the third approximation as a polynomial of the third degree in the atmospheric optical thickness

  3. 68Ga-PSMA-PET/CT imaging of localized primary prostate cancer patients for intensity modulated radiation therapy treatment planning with integrated boost.

    Science.gov (United States)

    Thomas, Lena; Kantz, Steffi; Hung, Arthur; Monaco, Debra; Gaertner, Florian C; Essler, Markus; Strunk, Holger; Laub, Wolfram; Bundschuh, Ralph A

    2018-07-01

    The purpose of our study was to show the feasibility and potential benefits of using 68 Ga-PSMA-PET/CT imaging for radiation therapy treatment planning of patients with primary prostate cancer using either integrated boost on the PET-positive volume or localized treatment of the PET-positive volume. The potential gain of such an approach, the improvement of tumor control, and reduction of the dose to organs-at-risk at the same time was analyzed using the QUANTEC biological model. Twenty-one prostate cancer patients (70 years average) without previous local therapy received 68 Ga-PSMA-PET/CT imaging. Organs-at-risk and standard prostate target volumes were manually defined on the obtained datasets. A PET active volume (PTV_PET) was segmented with a 40% of the maximum activity uptake in the lesion as threshold followed by manual adaption. Five different treatment plan variations were calculated for each patient. Analysis of derived treatment plans was done according to QUANTEC with in-house developed software. Tumor control probability (TCP) and normal tissue complication probability (NTCP) was calculated for all plan variations. Comparing the conventional plans to the plans with integrated boost and plans just treating the PET-positive tumor volume, we found that TCP increased to (95.2 ± 0.5%) for an integrated boost with 75.6 Gy, (98.1 ± 0.3%) for an integrated boost with 80 Gy, (94.7 ± 0.8%) for treatment of PET-positive volume with 75 Gy, and to (99.4 ± 0.1%) for treating PET-positive volume with 95 Gy (all p PET/CT image information allows for more individualized prostate treatment planning. TCP values of identified active tumor volumes were increased, while rectum and bladder NTCP values either remained the same or were even lower. However, further studies need to clarify the clinical benefit for the patients applying these techniques.

  4. Administered activity of Tc-99m MDP for bone scintigraphy, standard or individual dosage?

    International Nuclear Information System (INIS)

    Vestergren, E.; Gretarsdottir, J.; Jacobsson, L.

    2002-01-01

    Background and Aim: Adult patients are generally, irrespective of size, given the same amount of activity for a certain type of nuclear medicine examination, a standard dosage. Identical image quality is essential when comparing different patient studies. The aim of this study is to evaluate different dosage methods for Tc-99m-MDP bone scintigraphy and to investigate whether individual dosage will decrease the variations in image quality between different patients. Material and Methods: 100 consecutive adult patients (aged between 40 and 89 years) undergoing whole body bone scintigraphy were studied. Eight patients were excluded from the study because of abnormal high uptake in the areas of interest. The patient weight and height were registered. The activity in the syringes was measured before and after the injection of about 600 MBq Tc-99m MDP. Scanning was performed, with a dual head gamma camera (Maxxus or Millennium VG, General Electric) equipped with a high-resolution collimator, at approximately 4 hours (mean 3.8 h) post-injection. Regions of interest (ROI) were drawn over the lumbar spine (posterior view), the right femur (anterior view) and also soft tissue background regions for each area. The total counts, maximum counts/pixel and number of pixels in the ROIs were registered. The maximum number of counts/pixel (background-subtracted), SPINEmax and FEMURmax were chosen as the image quality parameters. For each patient, SPINEmax and FEMURmax where recalculated to the number that would have been obtained with standard dosage (exactly 600 MBq), and dosage proportional to body weight, body surface area and body height. All values were corrected to a scanning time 3.8 h after injection. Results: Both with a standard activity dosage and a dosage proportional to body height, SPINEmax decreases with increasing body weight. Dosage proportional to body weight gives increasing values of SPINEmax with increasing body weight. Dosage proportional to body surface area

  5. Methotrexate Dosage Reduction Upon Adalimumab Initiation: Clinical and Ultrasonographic Outcomes from the Randomized Noninferiority MUSICA Trial.

    Science.gov (United States)

    Kaeley, Gurjit S; Evangelisto, Amy M; Nishio, Midori J; Goss, Sandra L; Liu, Shufang; Kalabic, Jasmina; Kupper, Hartmut

    2016-08-01

    To examine the clinical and ultrasonographic (US) outcomes of reducing methotrexate (MTX) dosage upon initiating adalimumab (ADA) in MTX-inadequate responders with moderately to severely active rheumatoid arthritis (RA). MUSICA (NCT01185288) was a double-blind, randomized, parallel-arm study of 309 patients with RA receiving MTX ≥ 15 mg/week for ≥ 12 weeks before screening. Patients were randomized to high dosage (20 mg/week) or low dosage (7.5 mg/week) MTX; all patients received 40 mg open-label ADA every other week for 24 weeks. The primary endpoint was Week 24 mean 28-joint Disease Activity Score based on C-reactive protein (DAS28-CRP) to test for noninferiority of low-dosage MTX using a 15% margin. US images were scored using a 10-joint semiquantitative system incorporating OMERACT definitions for pathology, assessing synovial hypertrophy, vascularity, and bony erosions. Rapid improvement in clinical indices was observed in both groups after addition of ADA. The difference in mean DAS28-CRP (0.37, 95% CI 0.07-0.66) comparing low-dosage (4.12, 95% CI 3.88-4.34) versus high-dosage MTX (3.75, 95% CI 3.52-3.97) was statistically significant and non-inferiority was not met. Statistically significant differences were not detected for most clinical, functional, and US outcomes. Pharmacokinetic and safety profiles were similar. In MUSICA, Week 24 mean DAS28-CRP, the primary endpoint, did not meet non-inferiority for the low-dosage MTX group. Although the differences between the 2 MTX dosage groups were small, our study findings did not support routine MTX reduction in MTX inadequate responders initiating ADA.

  6. Feedback Control of Sex Determination by Dosage Compensation Revealed through Caenorhabditis Elegans Sdc-3 Mutations

    OpenAIRE

    DeLong, L.; Plenefisch, J. D.; Klein, R. D.; Meyer, B. J.

    1993-01-01

    In Caenorhabditis elegans, sex determination and dosage compensation are coordinately controlled through a group of genes that respond to the primary sex determination signal. Here we describe a new gene, sdc-3, that also controls these processes. In contrast to previously described genes, the sex determination and dosage compensation activities of sdc-3 are separately mutable, indicating that they function independently. Paradoxically, the sdc-3 null phenotype fails to reveal the role of sdc...

  7. Miniaturized approach for excipient selection during the development of oral solid dosage form

    DEFF Research Database (Denmark)

    Raijada, Dharaben Kaushikkumar; Müllertz, Anette; Cornett, Claus

    2014-01-01

    The present study introduces a miniaturized high-throughput platform to understand the influence of excipients on the performance of oral solid dosage forms during early drug development. Wet massing of binary mixtures of the model drug (sodium naproxen) and representative excipients was followed...... for excipient selection and for early-stage performance testing of active pharmaceutical ingredient intended for oral solid dosage form. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 103:900-908, 2014....

  8. Efficiency of individual dosage of digoxin with calculated concentration

    Directory of Open Access Journals (Sweden)

    Zhao L

    2014-07-01

    digoxin and creatinine clearance, our results show that although there was a significant correlation between clearance of digoxin and creatinine clearance in the group overall, correlations were not evident within the different stages of renal function.Conclusion: The results of this study indicate that clearance of digoxin and the creatinine clearance rate cannot be explained by renal function alone and that the validity of the Konishi equation for individualizing the digoxin dosage in Chinese patients is limited, being applicable only in stage 3 renal disease. Further research in larger numbers of patients across all stages of renal function will be required in the future to verify the original Konishi model. Keywords: serum digoxin concentration, predicted concentration, renal insufficiency

  9. Measurement of the lowest dosage of phenobarbital that can produce drug discrimination in rats

    Science.gov (United States)

    Overton, Donald A.; Stanwood, Gregg D.; Patel, Bhavesh N.; Pragada, Sreenivasa R.; Gordon, M. Kathleen

    2009-01-01

    Rationale Accurate measurement of the threshold dosage of phenobarbital that can produce drug discrimination (DD) may improve our understanding of the mechanisms and properties of such discrimination. Objectives Compare three methods for determining the threshold dosage for phenobarbital (D) versus no drug (N) DD. Methods Rats learned a D versus N DD in 2-lever operant training chambers. A titration scheme was employed to increase or decrease dosage at the end of each 18-day block of sessions depending on whether the rat had achieved criterion accuracy during the sessions just completed. Three criterion rules were employed, all based on average percent drug lever responses during initial links of the last 6 D and 6 N sessions of a block. The criteria were: D%>66 and N%50 and N%33. Two squads of rats were trained, one immediately after the other. Results All rats discriminated drug versus no drug. In most rats, dosage decreased to low levels and then oscillated near the minimum level required to maintain criterion performance. The lowest discriminated dosage significantly differed under the three criterion rules. The squad that was trained 2nd may have benefited by partially duplicating the lever choices of the previous squad. Conclusions The lowest discriminated dosage is influenced by the criterion of discriminative control that is employed, and is higher than the absolute threshold at which discrimination entirely disappears. Threshold estimations closer to absolute threshold can be obtained when criteria are employed that are permissive, and that allow rats to maintain lever preferences. PMID:19082992

  10. Personnel ionizing radiation dosimeter

    International Nuclear Information System (INIS)

    Williams, R.A.

    1975-01-01

    A dosimeter and method for use by personnel working in an area of mixed ionizing radiation fields for measuring and/or determining the effective energy of x- and gamma radiation; beta, x-, and gamma radiation dose equivalent to the surface of the body; beta, x-, and gamma radiation dose equivalent at a depth in the body; the presence of slow neutron, fast neutron dose equivalent; and orientation of the person wearing the dosimeter to the source of radiation is disclosed. Optionally integrated into this device and method are improved means for determining neutron energy spectrum and absorbed dose from fission gamma and neutron radiation resulting from accidental criticality

  11. Clinical features of radiation retinopathy

    International Nuclear Information System (INIS)

    Tabuchi, Shoko; Oda, Itsuo; Okawa, Tomohiko

    1977-01-01

    The clinical features of 25 cases with radiation retinopathy are described. Retinopathy was induced following therapeutic irradiation of paraobital malignancies with megavoltage Linac x-ray of 3,000 rads or more. Retinal vessels, particularly the proximal portion of retinal arteries, seemed to be the primary site of damage due to radiation. According to the type of lesion and dosage, fundus features simulated papillitis, retinal angiosclerosis, or hard exudates due to capillary obliteration. Acute obstruction of the central retinal artery and ischemic optic neuropathy could result from heavy irradiation of over 5,000 rads. (Evans, J.)

  12. Feasibility of integrating radiation-induced F1 sterility and biological control for population suppression of the pink bollworm, Pectinophora gossypiella, in Pakistan

    International Nuclear Information System (INIS)

    Ahmad, N.; Ashraf, M.; Hussain, T.; Qureshi, Z.A.

    2002-01-01

    Substitution of casein and wheat germ with locally available ingredients (chickpea flour, soybean flour, wheat husk and sawdust) in the specified casein-wheat germ diet affected various biological parameters of pink bollworm (PBW), Pectinophora gossypiella. The diet containing chickpea flour performed significantly better and is more economical than the other diets tested. The highest PBW field populations were recorded in the month of October when large numbers of fruiting bodies were present in the cotton. Field behavioural observations revealed that mating and other sexual activities of treated and native moths varied significantly with time of night and peak activity was during 03:00-04:00 hours. Male moths treated with 100 Gy as mature pupae responded well to gossyplure baited traps. The attraction of male moths to irradiated virgin females decreased significantly with increasing doses of radiation. Male moths responded more readily to virgin untreated females than to irradiated females. Field-cage studies demonstrated that irradiated moths (100 Gy) released at a 50:1 treated to normal ratio at three week intervals reduced larval infestations inside the cages to subeconomic level. Studies suggested that there is a great potential for integrating the egg parasitoid, Trichogramma chilonis, with the sterile insect technique to control cotton bollworms. (author)

  13. Transition of some type of integrated circuits into latch-up mode under effect of ionizing radiation of large dose rate

    International Nuclear Information System (INIS)

    Berdichevskij, B.E.; Madzharova, T.B.

    1986-01-01

    Some types of integrated circuits (IC) are almost short-circuit, i.e. they transit to the latch-up regime under the effect of ionizing radiation pulses of large dose rate. The results of investigation into IC under their transition into the latch-up regime at supply voltage of 10 V are presented. It is shown that IC stably transit to the latch-up regime if the dinistor current becomes at least equal to the photocurrent. At bias reduction from 15 to 6 V the dose rate at which the latch-up arises grows from 2.5x10 9 to 3.5x10 9 rad (Si)/s. Burn-out of supply busbar is the usual type of IC failure at latch-up arising. Measures for IC protection from latch-up are shown. In some IC the latch-up is formed beginning from a certain critical value of dose rate, the so-called ''windows'' of latch-up

  14. Heights integrated model as instrument for simulation of hydrodynamic, radiation transport, and heat conduction phenomena of laser-produced plasma in EUV applications.

    Energy Technology Data Exchange (ETDEWEB)

    Sizyuk, V.; Hassanein, A.; Morozov, V.; Sizyuk, T.; Mathematics and Computer Science

    2007-01-16

    The HEIGHTS integrated model has been developed as an instrument for simulation and optimization of laser-produced plasma (LPP) sources relevant to extreme ultraviolet (EUV) lithography. The model combines three general parts: hydrodynamics, radiation transport, and heat conduction. The first part employs a total variation diminishing scheme in the Lax-Friedrich formulation (TVD-LF); the second part, a Monte Carlo model; and the third part, implicit schemes with sparse matrix technology. All model parts consider physical processes in three-dimensional geometry. The influence of a generated magnetic field on laser plasma behavior was estimated, and it was found that this effect could be neglected for laser intensities relevant to EUV (up to {approx}10{sup 12} W/cm{sup 2}). All applied schemes were tested on analytical problems separately. Benchmark modeling of the full EUV source problem with a planar tin target showed good correspondence with experimental and theoretical data. Preliminary results are presented for tin droplet- and planar-target LPP devices. The influence of three-dimensional effects on EUV properties of source is discussed.

  15. Radiation retinopathy after orbital irradiation for Graves' ophthalmopathy

    International Nuclear Information System (INIS)

    Kinyoun, J.L.; Kalina, R.E.; Brower, S.A.; Mills, R.P.; Johnson, R.H.

    1984-01-01

    Recent reports indicate that orbital irradiation for Graves' ophthalmopathy is sometimes beneficial, particularly for dysthyroid optic neuropathy, and is not associated with serious complications. We are aware, however, of four patients who were found to have radiation retinopathy after orbital irradiation for Grave's ophthalmopathy. All four patients have decreased central acuity, and three of the four are legally blind in one or both eyes. Computer reconstruction of the dosimetry, based on computed tomography and beam profiles, shows that errors in dosage calculations and radiotherapy technique probably account for the radiation retinopathy in three of the four patients. Radiotherapy for Graves' ophthalmopathy should be administered only by competent radiotherapists who are experienced in the treatment of this disease. Similar errors in dosage calculations and treatment techniques may account for other reports of radiation retinopathy after reportedly safe dosages

  16. A Prospective Trial of Intensity Modulated Radiation Therapy (IMRT) Incorporating a Simultaneous Integrated Boost for Prostate Cancer: Long-term Outcomes Compared With Standard Image Guided IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Schild, Michael H. [Midwestern University, Glendale, Arizona (United States); Schild, Steven E., E-mail: sschild@mayo.edu [Department of Radiation Oncology, Mayo Clinic Hospital, Phoenix, Arizona (United States); Wong, William W.; Vora, Sujay A.; Keole, Sameer R.; Vargas, Carlos E.; Daniels, Thomas B.; Ezzell, Gary A. [Department of Radiation Oncology, Mayo Clinic Hospital, Phoenix, Arizona (United States); Nguyen, Ba D.; Roarke, Michael C. [Department of Radiology, Mayo Clinic, Scottsdale, Arizona (United States)

    2017-04-01

    Purpose: This report describes the long-term outcomes of a prospective trial of intensity modulated radiation therapy (IMRT), integrating a {sup 111}In capromab pendetide (ProstaScint) scan-directed simultaneous integrated boost (SIB) for localized prostate cancer. Methods and Materials: Seventy-one patients with T1N0M0 to T4N0M0 prostate cancer were enrolled, and their ProstaScint and pelvic computed tomography scans were coregistered for treatment planning. The entire prostate received 75.6 Gy in 42 fractions with IMRT, whereas regions of increased uptake on ProstaScint scans received 82 Gy as an SIB. Patients with intermediate- and high-risk disease also received 6 months and 12 months of adjuvant hormonal therapy, respectively. Results: The study enrolled 31 low-, 30 intermediate-, and 10 high-risk patients. The median follow-up was 120 months (range, 24-150 months). The 10-year biochemical control rates were 85% for the entire cohort and 84%, 84%, and 90% for patients with low-, intermediate-, and high-risk disease, respectively. The 10-year survival rate of the entire cohort was 69%. Pretreatment prostate-specific antigen level >10 ng/mL and boost volume of >10% of the prostate volume were significantly associated with poorer biochemical control and survival. The outcomes were compared with those of a cohort of 302 patients treated similarly but without the SIB and followed up for a median of 91 months (range, 6-138 months). The 5- and 10-year biochemical control rates were 86% and 61%, respectively, in patients without the SIB compared with 94% and 85%, respectively, in patients in this trial who received the SIB (P=.02). The cohort that received an SIB did not have increased toxicity. Conclusions: The described IMRT strategy, integrating multiple imaging modalities to administer 75.6 Gy to the entire prostate with a boost dose of 82 Gy, was feasible. The addition of the SIB was associated with greater biochemical control but not toxicity. Modern

  17. Health effects in residents of high background radiation regions

    International Nuclear Information System (INIS)

    Hanson, G.P.

    1984-01-01

    Although the health effects of radiation doses in occupationally exposed persons had received attention, it was not until the 1950s, when the atmospheric atom bomb tests of the United States and the Soviet Union had raised the level of environmental radioactivity, that the long-term effects of low-level radiation dosage became a matter of popular concern throughout the world. The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) was created, and the World Health Organization (WHO) appointed an expert committee to provide advice concerning radiation and human health. In its first report, the WHO expert committee identified several areas of high natural radiation where studies of the exposed population might possibly provide information concerning the effects of chromic low-level radiation dosage

  18. Relevance of dosage in adherence to treatment with long-acting anticholinergics in patients with COPD

    Directory of Open Access Journals (Sweden)

    Izquierdo JL

    2016-02-01

    Full Text Available José Luis Izquierdo,1 José Manuel Paredero,2 Raul Piedra3 1Department of Pneumology, Hospital Universitario de Guadalajara, 2Department of Pharmacy, 3Department of Primary Care, Guadalajara Integrated Care Management, Guadalajara, Spain Introduction: The aim of this study was to assess the degree of adherence for two standard regimens for administrating anticholinergic drugs (12 and 24 hours in patients with chronic obstruction of the airflow and to establish whether the use of a once-daily dose improves the level of treatment adherence.Methods: We used long-acting anticholinergics (LAMAs as a study variable, and included the entire health area of Castile-La Mancha, numbering 2,100,998 inhabitants, as the study population. We analyzed a total of 16,446 patients who had been prescribed a LAMA between January 1, 2013 and December 31, 2013. The follow-up period, based on a centralized system of electronic prescription management, was extended until December 2014.Results: During 2013, the medication collected was 7.4%–10.7% higher than indicated by labeling. This was very similar for all LAMAs, irrespective of the patient’s sex, the molecule, the device, and the drug dosage. We did not observe seasonal variations in the consumption of LAMAs, nor did we detect differences between prescription drugs for once-daily (every 24 hours versus twice-daily (every 12 hours administration, between the different molecules, or between different types of inhalers for the same molecule. The results were similar in 2014.Conclusion: The principal conclusion of this study is that, in an area with a centralized management system of pharmacological prescriptions, adherence to treatment with LAMAs is very high, irrespective of the molecules or inhalation device. We did not find that patients who used twice-daily medication had a lower adherence. Keywords: COPD, treatment, adherence, LABAs, LAMAs, PDC, asthma

  19. An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy.

    Science.gov (United States)

    Li, Hua; Chen, Hsin-Chen; Dolly, Steven; Li, Harold; Fischer-Valuck, Benjamin; Victoria, James; Dempsey, James; Ruan, Su; Anastasio, Mark; Mazur, Thomas; Gach, Michael; Kashani, Rojano; Green, Olga; Rodriguez, Vivian; Gay, Hiram; Thorstad, Wade; Mutic, Sasa

    2016-08-01

    For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28%  ±  1

  20. An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hua, E-mail: huli@radonc.wustl.edu; Chen, Hsin-Chen; Dolly, Steven; Li, Harold; Fischer-Valuck, Benjamin; Mazur, Thomas; Gach, Michael; Kashani, Rojano; Green, Olga; Rodriguez, Vivian; Gay, Hiram; Thorstad, Wade; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Victoria, James; Dempsey, James [ViewRay Incorporated, Inc., Oakwood Village, Ohio 44146 (United States); Ruan, Su [Laboratoire LITIS (EA 4108), Equipe Quantif, University of Rouen, Rouen 76183 (France); Anastasio, Mark [Department of Biomedical Engineering, Washington University, St. Louis, Missouri 63110 (United States)

    2016-08-15

    Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity