WorldWideScience

Sample records for integrated personalized ventilation

  1. Chair with Integrated Personalized Ventilation for Minimizing Cross Infection

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Bartholomaeussen, Niels Møller; Jakubowska, Ewa

    2007-01-01

    to the whole room to ensure a dilution of airborne infection. Personalized ventilation has proven to be a very efficient system to protect people from cross infection because clean air is supplied direct to the breathing zone. Most designs of personalized ventilation are based on a supply jet. The problem...

  2. Personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  3. Bed with Integrated Personalized Ventilation for Minimizing Cross Infection

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jiang, Hao; Polak, Marcin

    2007-01-01

    of air to the whole room to ensure a dilution of airborne infection. Personalized ventilation has proven to be a very efficient system to protect people from cross infection because clean air is supplied direct to the breathing zone. Most designs of personalized ventilation are based on a supply jet....... The problem with those systems is the fact that the jet entrains air from the surroundings and, therefore, reduces the amount of fresh air which reaches the breathing zone. The entrainment is minimized in the system discussed here, especially when the source of clean air is located in the boundary layer close...

  4. Free Convection Personalized Ventilation (FCPV)

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Normally we supply fresh air to a room with a diffuser, and this air is distributed in the room according to different principles as: mixing ventilation, displacement ventilation etc. That means we have to supply a very large amount of air to the whole room, although a person in the room totally ...

  5. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human...

  6. Human response to ductless personalized ventilation coupled with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Veselý, Michal; Melikov, Arsen K.

    2012-01-01

    A human subject experiment was carried out to investigate the extent to which ductless personalized ventilation (DPV) in conjunction with displacement ventilation can improve perceived air quality (PAQ) and thermal comfort at elevated room air temperature in comparison with displacement ventilation...... alone. The experimental conditions comprised displacement ventilation alone (room air temperature of 23 °C, 26 °C, 29 °C) and DPV with displacement ventilation (26 °C, 29 °C), both operating at supply air temperatures 3, 5 or 6K lower than room air temperature, as well as mixing ventilation (23 °C, 3 K......). During one hour exposure participants answered questionnaires regarding PAQ and thermal comfort. PAQ was significantly better with DPV than without DPV at the same background conditions. Thermal comfort improved when DPV was used. Combining DPV with displacement ventilation showed the potential...

  7. Contaminant Distribution Around Persons in Rooms Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.

    An optimal design of the ventilation system needs a proper prediction of the velocity, temperature and contaminant distribution in the room. Traditionally this is done either by the use of simplified models or by a somewhat more comprehensive CFD-simulation. Common to both methods is usually...... the lack of consideration for the persons present in the room. This paper deals with some of the effects of persons present in a displacement ventilated room, especially the effect on the contaminant distribution....

  8. Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system - a human response study in hot and humid climate

    DEFF Research Database (Denmark)

    Bin, Yang; Sekhar, S.C.; Melikov, Arsen Krikor

    2010-01-01

    The benefits of thermal comfort and indoor air quality with personalized ventilation (PV) systems have been demonstrated in recent studies. One of the barriers for wide spread acceptance by architects and HVAC designers has been attributed to challenges and constraints faced in the integration...... performed with tropically acclimatized subjects in a Field Environmental Chamber. Thirty-two subjects performed normal office work and could choose to be exposed to four different PV airflow rates (4, 8, 12, and 16 L/s), thus offering themselves a reasonable degree of individual control. Ambient...

  9. Ductless personalized ventilation with local air cleaning

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks was equip......An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks...... was equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C. The pollution load in the room was simulated by PVC floor covering. The subjects assessed...

  10. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation......Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... contaminant sources, this entrainment improves the indoor air quality. Measurements of exposure due to a passive contaminant source show a significant dependence on the flow field as well as on the contaminant source location. Poor system performance is found in the case of a passive contaminant released...

  11. Energy Analysis of the Ductless Personalized Ventilation

    DEFF Research Database (Denmark)

    Lelong, Cyril; Dalewski, Mariusz; Melikov, Arsen Krikor

    2013-01-01

    energy efficient strategies for implantation of DPV in practice. The impact of using DPV on annual energy use has been studied for different occupancy profiles in cold climates. The results suggest that using DPV combined with displacement ventilation may significantly reduce building energy use while......This study explores the impact of different occupancy profiles on the potential energy savings due to using ductless personalized ventilation (DPV) combined with displacement ventilation. Energy simulations were performed with the dynamic simulation software IDA-ICE in order to investigate optimal...

  12. Performance of ductless personalized ventilation in conjunction with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Melikov, Arsen Krikor; Vesely, Michal

    2014-01-01

    perception of the environment. The subjects could control the position of the DPV supply diffuser and the personalized air flow (air velocity). The use of DPV improved perceived air quality and thermal comfort compared to displacement ventilation alone. At 26 °C and 29 °C the percentage dissatisfied with air......, increased eye dryness sensation was reported by 30% of subjects. The personalized air flow selected by nearly 80% of the subjects at 26 °C was between 10 and 20 l/s corresponding to the target air velocity of 1.2–1.7 m/s. At 29 °C almost 90% of subjects chose a personalized air flow between 15 and 20 l/s (1...

  13. Improving comfort and health with personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants¿ health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analysed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  14. Thermal comfort of seated occupants in rooms with personalized ventilation combined with mixing or displacement ventilation

    DEFF Research Database (Denmark)

    Forejt, L.; Melikov, Arsen Krikor; Cermak, Radim

    2004-01-01

    The performance of two personalized ventilation systems combined with mixing or displacement ventilation was studied under different conditions in regard to thermal comfort of seated occupants. The cooling performance of personalized ventilation was found to be independent of room air distribution...

  15. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  16. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar, S.C.; Melikov, Arsen Krikor

    2010-01-01

    The potential for improving occupants' thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied...... of the results obtained reveal improved acceptability of perceived air quality and improved thermal sensation with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with ceiling supply diffuser. The local thermal sensation at the feet was also improved when warmer UFAD supply air...

  17. Air quality Performance of Ductless Personalized Ventilation in Conjunction with Displacement Ventilation: Impact of Walking Person

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Lu, Pengfei; Melikov, Arsen Krikor

    2015-01-01

    The present experiment evaluates the impact of air disturbances from a walking person on inhaled air by ductless personalized ventilation (DPV) with displacement ventilation (DV), when a seated occupant is the source of pollution: bio-effluents and exhaled air. The measurements took place in a full...... and the DV supply. Pollution from feet and exhaled air by one manikin was simulated with tracer gases. Room temperature of 26 °C and 90 L/s DV supply flow rate were kept constant. Measurements under numerous combinations of DPV operation modes and supply flow rates were performed. Tracer gas concentrations...

  18. Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system--a human response study in hot and humid climate.

    Science.gov (United States)

    Yang, B; Sekhar, S C; Melikov, A K

    2010-08-01

    The benefits of thermal comfort and indoor air quality with personalized ventilation (PV) systems have been demonstrated in recent studies. One of the barriers for wide spread acceptance by architects and HVAC designers has been attributed to challenges and constraints faced in the integration of PV systems with the work station. A newly developed ceiling-mounted PV system addresses these challenges and provides a practical solution while retaining much of the apparent benefits of PV systems. Assessments of thermal environment, air movement, and air quality for ceiling-mounted PV system were performed with tropically acclimatized subjects in a Field Environmental Chamber. Thirty-two subjects performed normal office work and could choose to be exposed to four different PV airflow rates (4, 8, 12, and 16 L/s), thus offering themselves a reasonable degree of individual control. Ambient temperatures of 26 and 23.5 degrees C and PV air temperatures of 26, 23.5, and 21 degrees C were employed. The local and whole body thermal sensations were reduced when PV airflow rates were increased. Inhaled air temperature was perceived cooler and perceived air quality and air freshness improved when PV airflow rate was increased or temperature was reduced. The newly developed ceiling-mounted PV system offers a practical solution to the integration of PV air terminal devices (ATDs) in the vicinity of the workstation. By remotely locating the PV ATDs on the ceiling directly above the occupants and under their control, the conditioned outdoor air is now provided to the occupants through the downward momentum of the air. A secondary air-conditioning and air distribution system offers additional cooling in the room and maintains a higher ambient temperature, thus offering significant benefits in conserving energy. The results of this study provide designers and consultants with needed knowledge for design of PV systems.

  19. Boundary conditions for the use of personal ventilation over mixing ventilation in open plan offices

    DEFF Research Database (Denmark)

    Petersen, Steffen; Hviid, Christian Anker

    2013-01-01

    This paper investigates the boundary conditions for choosing a combined Personal Ventilation (PV) and Mixing Ventilation (MV) over conventional mixing ventilation in an office with multiple workers. A simplified procedure for annual performance assessment of PV/MV systems in terms of air quality...

  20. Personalizing mechanical ventilation for acute respiratory distress syndrome.

    Science.gov (United States)

    Berngard, S Clark; Beitler, Jeremy R; Malhotra, Atul

    2016-03-01

    Lung-protective ventilation with low tidal volumes remains the cornerstone for treating patient with acute respiratory distress syndrome (ARDS). Personalizing such an approach to each patient's unique physiology may improve outcomes further. Many factors should be considered when mechanically ventilating a critically ill patient with ARDS. Estimations of transpulmonary pressures as well as individual's hemodynamics and respiratory mechanics should influence PEEP decisions as well as response to therapy (recruitability). This summary will emphasize the potential role of personalized therapy in mechanical ventilation.

  1. Osobni Větráni (Personalized ventilation)

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2003-01-01

    Personalized ventilation provides clean air at each workplace. The aim is to improve substantially the quality of air inhaled by each occupant and to ensure thermal comfort. Each occupant is provided with the possibility to generate and control his/her microclimate. This article summarizes...... and discusses the principles involved and outlines recent results on the performance of personalized ventilation....

  2. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruixin [Department of Building, National University of Singapore (Singapore); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark (Denmark); Sekhar, S.C. [Department of Building, National University of Singapore (Singapore); Melikov, A.K. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark (Denmark)

    2010-09-15

    The potential for improving occupants' thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied by UFAD system and uncomfortable sensation as ''warm head'' can be reduced by the PV system providing cool and fresh outdoor air at the facial level. A study with 30 human subjects was conducted in a Field Environmental Chamber. The chamber was served by two dedicated systems - a primary air handling unit (AHU) for 100% outdoor air that is supplied through the PV air terminal devices and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Responses of the subjects to the PV-UFAD system were collected at various room air and PV air temperature combinations. The analyses of the results obtained reveal improved acceptability of perceived air quality and improved thermal sensation with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with ceiling supply diffuser. The local thermal sensation at the feet was also improved when warmer UFAD supply air temperature was adopted in the PV-UFAD system. (author)

  3. Personal Exposure to Contaminant Sources in Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik

    Three different tools for personal exposure assessment are presented. They are all able to consider the local influence of persons in ventilated rooms where concentration gradients prevail: A Breathing Thermal Manikin, a Computer Simulated Person, and a Trained Sensory Panel. The tools are applied...

  4. Personalizing mechanical ventilation for acute respiratory distress syndrome

    OpenAIRE

    Berngard, S. Clark; Beitler, Jeremy R.; Malhotra, Atul

    2016-01-01

    Lung-protective ventilation with low tidal volumes remains the cornerstone for treating patient with acute respiratory distress syndrome (ARDS). Personalizing such an approach to each patient's unique physiology may improve outcomes further. Many factors should be considered when mechanically ventilating a critically ill patient with ARDS. Estimations of transpulmonary pressures as well as individual's hemodynamics and respiratory mechanics should influence PEEP decisions as well as response ...

  5. Energy-saving strategies with personalized ventilation in cold climates

    DEFF Research Database (Denmark)

    Shiavon, Stefano; Melikov, Arsen Krikor

    2009-01-01

    In this study the influence of the personalized supply air temperature control strategy on energy consumption and the energy-saving potentials of a personalized ventilation system have been investigated by means of simulations with IDA-ICE software. GenOpt software was used to determine the optimal...

  6. Measurements and prediction of inhaled air quality with personalized ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Majer, M.; Melikov, Arsen Krikor

    2002-01-01

    the room air) at flow rates ranging from less than 5 L/s up to 23 L/s. The air quality assessment was based on temperature measurements of the inhaled air and on the portion of the personalized air inhaled. The percentage of dissatisfied with the air quality was predicted. The results suggest......This paper examines the performance of five different air terminal devices for personalized ventilation in relation to the quality of air inhaled by a breathing thermal manikin in a climate chamber. The personalized air was supplied either isothermally or non-isothermally (6 deg.C cooler than...... that regardless of the temperature combinations, personalized ventilation may decrease significantly the number of occupants dissatisfied with the air quality. Under non-isothermal conditions the percentage of dissatisfied may decrease up to 4 times....

  7. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets

    DEFF Research Database (Denmark)

    Pantelic, J.; Tham, K. W.; Licina, Dusan

    2015-01-01

    manikin at distances between 1 and 4m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced......The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal...

  8. Human Response to Personalized Ventilation Combined with Chilled Ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Marcol, Bartosz

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. Previous research was focused on combining PV with additional total volume air distribution, i.e. mixing ventilation or displacement ventilation......, the use of radiant ceiling cooling will provide operative temperature lower than the air temperature and will improve further occupants’ thermal comfort at warm environment. Therefore combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at temperature higher than...... temperature for chilled ceiling was 15,5/16,8°C at room air temperature of 26°C and 19,5/20,6°C at 28°C. During the experiment the subjects were performing typical office tasks at workstations with computers. Exposure included also increased activity level office work for a period of 25 min...

  9. Experimental study on human exposure to occupant generated pollutants in rooms with ductless personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Bolashikov, Zhecho Dimitrov; Lu, Pengfei

    2014-01-01

    The performance of “ductless” personalized ventilation in conjunction with displacement ventilation with regard to exposure to different body bioeffluents was studied. Experiments were performed in a full-scale room furnished as a double office. Room air temperature was kept at 26 oC. Two breathing...... modes for the ductless personalized and displacement ventilation were tested. The location of the bioeffluent source affected the spread of body bioeffluents in the space. The ductless personalized ventilation provided cleaner air to both occupants than displacement ventilation alone. Occupants using...... the ”ductless” system will perceive the supplied air quality as superior compared to displacement ventilation alone....

  10. Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Svendsen, Sv Aa Højgaard

    1999-01-01

    The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger.......The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger....

  11. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets.

    Science.gov (United States)

    Pantelic, J; Tham, K W; Licina, D

    2015-12-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems’ performance and can serve as an aid in making critical design decisions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Integrating personality structure, personality process, and personality development

    NARCIS (Netherlands)

    Baumert, Anna; Schmitt, Manfred; Perugini, Marco; Johnson, Wendy; Blum, Gabriela; Borkenau, Peter; Costantini, Giulio; Denissen, J.J.A.; Fleeson, William; Grafton, Ben; Jayawickreme, Eranda; Kurzius, Elena; MacLeod, Colin; Miller, Lynn C.; Read, Stephen J.; Robinson, Michael D.; Wood, Dustin; Wrzus, Cornelia

    2017-01-01

    In this target article, we argue that personality processes, personality structure, and personality development have to be understood and investigated in integrated ways in order to provide comprehensive responses to the key questions of personality psychology. The psychological processes and

  13. Experimental investigation of reduced-mixing personal ventilation jets

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, H. Ezzat; Janos, Michael I.; Dannenhoffer, John F. III. [Syracuse University, Syracuse, NY (United States)

    2009-08-15

    This paper presents an investigation of the design and performance characteristics of personalized ventilation (PV) systems that, in combination with general ventilation, deliver high quality air to the breathing zone (BZ) with no more clean air supply than indicated by ANSI/ASHRAE 62.1-2004, while satisfying acceptable ergonomic and aesthetic considerations. Under these conditions, the energy used for conditioning the clean air will not exceed that of a conventional ventilation system. We introduce a novel PV nozzle that achieves high BZ air quality with a small fraction of the clean air indicated by the ANSI/ASHRAE Standard. Tracer gas experimental results presented in this paper demonstrate the advantages of the novel nozzle relative to conventional PV nozzles. The results show that, at a PV clean air supply of only 2.4 l/s, the new nozzle achieves a BZ ventilation effectiveness close to 7 versus less than 2 for a conventional nozzle delivering the same amount of clean air. A companion paper presents a computational analysis of the same concept, validated against the experimental results of the present paper. (author)

  14. Personal Integrity and Leadership

    Directory of Open Access Journals (Sweden)

    Antonius Gea

    2016-07-01

    Full Text Available Generally, integrity is associated with leadership, especially in the organization or company. Integrity in leadership becomes a growing concern in business and organizations. The aim of this study was to find out the connection that could be shaped between personal integrity and the skill of leadership especially in the performance of work. This study used a library research, a literature study that done by using the available resources and relevant literature, related to the topic being discussed by the author. Books or journal articles related to topics were used as background reading to understand well about the problems of integrity and leadership, especially in the organization or company. This study finds out that the leader integrity is related to follower work role performance and that this effect is fully mediated through follower affective organizational commitment. 

  15. Personalized ventilation: evaluation of different air terminal devices

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Majer, M.

    2002-01-01

    Personalized ventilation (PV) aims to provide clean air to the breathing zone of occupants. Its performance depends to a large extent on the supply air terminal device (ATD). Five different ATDs were developed, tested and compared. A typical office workplace consisting of a desk with mounted ATDs...... was simulated in a climate chamber. A breathing thermal manikin was used to simulate a human being. Experiments at room air temperatures of 26 and 20 deg.C and personalized air temperatures of 20 deg.C supplied from the ATDs were performed. The flow rate of personalized air was changed from less than 5 up to 23...... l/s. Tracer gas was used to identify the amount of personalized air inhaled by the manikin as well as the amount of exhaled air re-inhaled. The heat loss from the body segments of the thermal manikin was measured and used to calculate the equivalent temperature for the whole body as well as segments...

  16. Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    Science.gov (United States)

    Yang, J; Sekhar, S C; Cheong, K W D; Raphael, B

    2015-04-01

    In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system has been developed, which aims to exhaust the exhaled air as much as possible from around the infected person (IP). The PV-PE system was studied experimentally for a particular healthcare setting based on a typical consultation room geometry and four different medical consultation positions of an IP and a healthy person (HP). Experiments using two types of tracer gases were conducted to evaluate two types of PE: Top-PE and Shoulder-PE under two different background ventilation systems: Mixing Ventilation and Displacement Ventilation. Personalized exposure effectiveness, intake fraction (iF) and exposure reduction (ε) were used as indices to evaluate the PV-PE system. The results show that the combined PV-PE system for the HP achieves the lowest intake fraction; and the use of PE system for the IP alone shows much better performance than using PV system for the HP alone. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P.V.; Hyldgaard, C.E.; Melikov, Arsen Krikor

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... manikin is the source and the other the target. In general it was found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with limited protection of the occupants. Selected locations of supply, return, and heat sources can produce a displacement flow...

  18. Integrated Stress Response Mediates Epithelial Injury in Mechanical Ventilation.

    Science.gov (United States)

    Dolinay, Tamas; Himes, Blanca E; Shumyatcher, Maya; Lawrence, Gladys Gray; Margulies, Susan S

    2017-08-01

    Ventilator-induced lung injury (VILI) is a severe complication of mechanical ventilation that can lead to acute respiratory distress syndrome. VILI is characterized by damage to the epithelial barrier with subsequent pulmonary edema and profound hypoxia. Available lung-protective ventilator strategies offer only a modest benefit in preventing VILI because they cannot impede alveolar overdistension and concomitant epithelial barrier dysfunction in the inflamed lung regions. There are currently no effective biochemical therapies to mitigate injury to the alveolar epithelium. We hypothesize that alveolar stretch activates the integrated stress response (ISR) pathway and that the chemical inhibition of this pathway mitigates alveolar barrier disruption during stretch and mechanical ventilation. Using our established rat primary type I-like alveolar epithelial cell monolayer stretch model and in vivo rat mechanical ventilation that mimics the alveolar overdistension seen in acute respiratory distress syndrome, we studied epithelial responses to mechanical stress. Our studies revealed that the ISR signaling pathway is a key modulator of epithelial permeability. We show that prolonged epithelial stretch and injurious mechanical ventilation activate the ISR, leading to increased alveolar permeability, cell death, and proinflammatory signaling. Chemical inhibition of protein kinase RNA-like endoplasmic reticulum kinase, an upstream regulator of the pathway, resulted in decreased injury signaling and improved barrier function after prolonged cyclic stretch and injurious mechanical ventilation. Our results provide new evidence that therapeutic targeting of the ISR can mitigate VILI.

  19. Distribution of contaminants in the occupied zone of a room with personalized and displacement ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor; Forejt, L.

    2004-01-01

    A distribution of contaminants from floor covering, exhaled air and human bioeffluents was examined in a mock-up of a typical two-person office by means of tracer-gases. The distribution was studied with two types of air terminal device for personalized ventilation combined with displacement...... ventilation. The results document that the distribution of contaminants depends to a great extent on the type and operation of personalized ventilation, as well as on the type and location of contaminant sources....

  20. [Anesthesia ventilators].

    Science.gov (United States)

    Otteni, J C; Beydon, L; Cazalaà, J B; Feiss, P; Nivoche, Y

    1997-01-01

    To review anaesthesia ventilators in current use in France by categories of ventilators. References were obtained from computerized bibliographic search. (Medline), recent review articles, the library of the service and personal files. Anaesthesia ventilators can be allocated into three groups, depending on whether they readminister expired gases or not or allow both modalities. Contemporary ventilators provide either constant volume ventilation, or constant pressure ventilation, with or without a pressure plateau. Ventilators readministering expired gases after CO2 absorption, or closed circuit ventilators, are either of a double- or a single-circuit design. Double-circuit ventilators, or pneumatical bag or bellows squeezers, or bag-in-bottle or bellows-in-bottle (or box) ventilators, consist of a primary, or driving circuit (bottle or box) and a secondary or patient circuit (including a bag or a bellows or membrane chambers). Bellows-in-bottle ventilators have either standing bellows ascending at expiration, or hanging bellows, descending at expiration. Ascending bellows require a positive pressure of about 2 cmH2O throughout exhalation to allow the bellows to refill. The expired gas volume is a valuable indicator for leak and disconnection. Descending bellows generate a slight negative pressure during exhalation. In case of leak or disconnection they aspirate ambient air and cannot act therefore as an indicator for integrity of the circuit and the patient connection. Closed circuit ventilators with a single-circuit (patient circuit) include a insufflating device consisting either in a bellows or a cylinder with a piston, operated by a electric or pneumatic motor. As the hanging bellows of the double circuit ventilators, they generate a slight negative pressure during exhalation and aspirate ambient air in case of leak or disconnection. Ventilators not designed for the readministration of expired gases, or open circuit ventilators, are generally stand

  1. Operational test report integrated system test (ventilation upgrade)

    Energy Technology Data Exchange (ETDEWEB)

    HARTY, W.M.

    1999-10-05

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

  2. Operational test report, integrated system test (ventilation upgrade)

    International Nuclear Information System (INIS)

    HARTY, W.M.

    1999-01-01

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, AY102, AZ101, AZ102

  3. Integrating the persons communicating

    DEFF Research Database (Denmark)

    Hermann, Jesper

    2011-01-01

    The paper presents some grounds for the working out of insights developed by Roy Harris and the fellow integrationalists, including the person-centered focus of Otto Jespersen when dealing with future communication studies. Whenever we are speaking of ‘something verbal’, immediately we are opening...... of ‘language’ evaporates, and we are left solely with persons and their understandings, actions and expressions to be investigated by us professionals, collaborating with the persons under scrutiny....

  4. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings.......In a simulated two persons’ office room inhaled air quality and contaminant distribution provided with personalized ventilation combined with chilled ceiling, mixing ventilation only, chilled ceiling with mixing ventilation and chilled ceiling with mixing and personalized ventilation was studied...

  5. Inhaled air quality with desk incorporated personalized ventilation (PV): parametric study

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Nagano, Hideaki; Melikov, Arsen Krikor

    A workstation consisting of a desk with installed personalized ventilation (PV) and a dressed breathing thermal manikin simulating seated occupant was set in a full-scale test room. The room was conditioned by overhead ventilation at 26 oC. The PV consisted of two confluent jets incorporated along...

  6. Confidentiality and personal integrity.

    Science.gov (United States)

    Edgar, A

    1994-06-01

    This paper uses the social theory of Erving Goffman in order to argue that confidentiality should be understood in relation to the mundane social skills by which individuals present and respect specific self-images of themselves and others during social interaction. The breaching of confidentiality is analysed in terms of one person's capacity to embarrass another, and so to expose that person as incompetent. Respecting confidentiality may at once serve to protect the vulnerable from an unjust society, and yet also protect the guilty from just accusation. Ethical reasoning about confidentiality must therefore recognize the dangers of prejudice and violence inherent in decisions to breach or to respect confidentiality. Case studies are used to illustrate the efficacy of this account, culminating with analyses of three examples from the UKCC document Confidentiality.

  7. Co-occupant's exposure to exhaled pollutants with two types of personalized ventilation strategies under mixing and displacement ventilation systems.

    Science.gov (United States)

    Li, X; Niu, J; Gao, N

    2013-04-01

    Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of PV systems with upward supplied fresh air, namely a chair-based PV and one kind of desk-mounted PV systems, when combined with mixing ventilation (MV) and displacement ventilation (DV) systems, are investigated using simulation method with regard to their impacts on co-occupant's exposure to the exhaled droplet nuclei generated by the infected PV user. Simulation results of tracer gas and particles with aerodynamic diameter of 1, 5, and 10 μm from exhaled air show that, when only the infected person uses a PV, the different PV air supplying directions present very different impacts on the co-occupant's intake under DV, while no apparent differences can be observed under MV. The findings demonstrate that better inhaled air quality can always be achieved under DV when the adopted PV system can deliver conditioned fresh air in the same direction with the mainly upward airflow patterns of DV. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  8. Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2015-01-01

    The thermal environment and air quality conditions provided with combined system of chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for two occupants. The proposed system was compared with total volume HVAC solutions used today, namely mixing ventilation...... and chilled ceiling combined with mixing ventilation. The objective of the study was to evaluate whether PV can be the only ventilation system in the rooms equipped with chilled ceiling. The room air temperature was 26°C in cases with traditional systems and 28°C when PV was used. PV supplied air...... with the temperature of 25°C. PV improved thermal conditions and was up to nearly 10 times more efficient in delivering clean air at workstations than mixing ventilation systems, which resulted in strong protection of occupants from the cross-infection. In the room space outside workstations no substantial differences...

  9. Integrating Personal and Professional Development.

    Science.gov (United States)

    Lippitt, Gordon L.

    1980-01-01

    The author outlines ways to integrate work identity and social identity in order to improve the quality of life. He presents a model for maintaining balance between personal and professional growth, which can stimulate achievement in six areas of human potential. (SK)

  10. Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2007-01-01

    the concentration of exhaled air pollution increased in the room. The two types of personalized ventilation performed differently. Subsequent analyses of airborne infection transmission risk indicated that personalized ventilation could become a supplement to traditional methods of infection control....... of pollutants associated with exhaled air and floor material emissions was evaluated at various combinations of personalized and underfloor airflow rates. Compared to underfloor ventilation alone, personalized and underfloor ventilation provided excellent protection Of seated occupants from any pollution, while......The performance of two personalized. ventilation systems supplying air at the breathing zone was tested in conjunction with underfloor ventilation generating two different airflow patterns in a full-scale test room. Two breathing thermal manikins were used to simulate occupants. The distribution...

  11. Improved Performance of Personalized Ventilation by Control of the Convection Flow around Occupant Body

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Krenek, Miroslav

    2009-01-01

    This paper reports on methods of control of the free convection flow around human body aiming at improvement of inhaled air quality for occupants at workstations with personalized ventilation (PV). Two methods of control were developed and explored: passive - blocking the free convection developm......This paper reports on methods of control of the free convection flow around human body aiming at improvement of inhaled air quality for occupants at workstations with personalized ventilation (PV). Two methods of control were developed and explored: passive - blocking the free convection......-scale test room with background mixing ventilation. Thermal manikin with realistic free convection flow was used. The PV supplied air from front/above towards the face. All measurements were performed under isothermal conditions at 20 °C and 26 °C. The air in the test room was mixed with tracer gas, while...

  12. Potential energy savings with personalized ventilation coupled with passive chilled beams

    DEFF Research Database (Denmark)

    Lyubenova, Velina S.; Holsøe, Jan W.; Melikov, Arsen Krikor

    2011-01-01

    Personalized ventilation (PV) is an individually controlled air distribution system aimed at improving inhaled air quality and thermal comfort of each occupant. Numerous studies have shown that PV may improve occupants’ health, comfort and performance in comparison with traditional total volume air...... saving especially in spaces where occupants spend most of the time at their workplace....

  13. Anaesthesia ventilators

    OpenAIRE

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bello...

  14. Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Ivanova, T.; Stefanova, G.

    2012-01-01

    inhaled by the manikin was measured and used to assess the clean air supply efficiency of the SHPV. The response of 35 subjects was collected to examine thermal comfort with the SHPV. The subjects participated in 3 experiments at personalized air temperature and room air temperature of 22/20 °C, 23/23 °C......The performance of personalized ventilation with seat headrest-mounted air supply terminal devices (ATD), named seat headrest personalized ventilation (SHPV), was studied. Physical measurements using a breathing thermal manikin were taken to identify its ability to provide clean air to inhalation...... depending on design, shape, size and positioning of the ATD, flow rate and temperature of personalized air, room temperature, clothing thermal insulation of the manikin, etc. Tracer gas was mixed with the room air. The air supplied by the SHPV was free of tracer gas. Tracer gas concentration in the air...

  15. Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Kovar, O.

    2003-01-01

    The impact of airflow interaction on inhaled air quality and transport of contaminants between occupants was studied in regard to pollution from floor covering, human bioeffluents and exhaled air, with combinations of two personalized ventilation systems (PV) with mixing and displacement...... quality with personalized and mixing ventilation was higher or at least similar compared to mixing ventilation alone. In the case of PV combined with displacement ventilation, the interaction caused mixing of the room air, an increase in the transport of bioeffluents and exhaled air between occupants and...... ventilation. In total, 80 L/s of clean air supplied at 20°C was distributed between the ventilation systems at different combinations of personalized airflow rate. Two breathing thermal manikins were used to simulate occupants in a full-scale test room. Regardless of the airflow interaction, the inhaled air...

  16. Impact of personalized ventilation combined with chilled ceiling on eye irritation symptoms

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Marcol, Bartosz; Kaczmarczyk, Jan

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. The PV alone can be used for room ventilation when applied in conjunction with ceiling radiant cooling system, which removes sensible heat loads...... from the space. Combining PV with chilled ceiling may be an effective way to provide thermal comfort in rooms at air temperature higher than the recommended in the standards upper limit of 26°C (category II), because the operative temperature will be lower. However, combination of high air temperature...

  17. Anaesthesia ventilators

    Directory of Open Access Journals (Sweden)

    Rajnish K Jain

    2013-01-01

    Full Text Available Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV. PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits.

  18. Anaesthesia ventilators.

    Science.gov (United States)

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-09-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV). PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits.

  19. Anaesthesia ventilators

    Science.gov (United States)

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV). PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits. PMID:24249886

  20. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    This study presents a novel method for advanced ventilation of hospital wards leading to improved air quality at reduced ventilation rate. The idea is to evacuate the bio-effluents generated from patients’ body by local exhaustion before being spread in the room. This concept was realized by using...... a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air...... conditioned via mixing total volume ventilation system supplying air through a ceiling mounted diffuser. All experiments were performed at room air temperature of 23ºC. A thermal manikin was used to simulate a polluting patient on the bed equipped with the ventilated mattress. Two heated dummies were used...

  1. Respiratory alkalosis and associated electrolytes in long-term ventilator dependent persons with tetraplegia.

    Science.gov (United States)

    Watt, J W; Silva, P

    2001-11-01

    A pilot case control study of the acid-base and electrolyte status in 30 long-term ventilator-dependent (LTVD) and 30 self ventilating persons with tetraplegia. To assess the extent of respiratory alkalosis and screen for associated hypokalaemia, hypomagnesaemia and/or hypophosphataemia. Medically stable persons with tetraplegia under the long-term care of the Southport Spinal Injuries Centre, England. Blood gases and electrolytes were sampled from 30 control patients with tetraplegia and from 30 patients having been LTVD for more than 12 months. All the blood gas measurements in the LTVD group lay outside both the reference range and the 95% confidence intervals (CI) of the control group: pH 7.46 (0.06); PCO(2) 3.46 (1.1) kPa; bicarbonate 18.3 (3.8) and base excess -3.2 (2.8) mmol/l; PO(2) 13.8 (2.8) kPa (means and standard deviations). The serum potassium, magnesium, phosphate, and sodium means lay within the reference ranges but the potassium, phosphate and calcium were at or below the 95% CI of the control values. One patient on part-time ventilatory support having less bicarbonate compensation had low serum electrolytes during ventilation. There was no evidence of biochemical jeopardy from long-term mechanical hyperventilation although acutely administered hyperventilation has the potential to cause falls in serum potassium, magnesium and phosphate and so caution should be exercised in part-time ventilated persons. The full range of electrolytes should be assayed during stabilisation in LTVD and periodically thereafter. Hyperventilation helps to maintain good oxygenation in LTVD persons with paralysis and normal lungs. None.

  2. Energy Saving by Novel Bed-Integrated Local Exhaust Ventilation

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Kehayova, Nushka; Melikov, Arsen Krikor

    2016-01-01

    High quality indoor environment in hospitals is important for patients’ healing and performance of the personnel. A novel method for minimizing spread of bio-effluents generated from hospitalized patients lying in bed was developed. The method consists of ventilated mattress (VM) which is able...... respectively with 55%, 71.1% and 85.9% and in the double room with 39.3%, 60.0%, and 80.4%. The use of the VM with reduced background CAV ventilation is an effective energy saving strategy for both double and single patient hospital rooms.......-bed hospital patient room (1.3 air changes per hour (ACH)) and double-bed patient room (1.6 ACH) was assessed by means of dynamic computer simulations. The estimated annual energy consumption for the rooms using the VM combined with CAV was compared to the annual energy consumption when the CAV ventilation...

  3. Performance of personalized ventilation in a room with an underfloor air distribution system: transport of contaminants between occupants

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2003-01-01

    the workplaces has not been studied in detail. This paper presents a study on the performance of a personalized ventilation system installed in a full-scale test room with an underfloor air distribution system. Transport of human-produced airborne pollutants (in real life they can be infectious agents) between......Studies have documented that personalized ventilation, which provides clean air at each office workplace, is able to improve substantially the quality of air inhaled by occupants. However, the interaction between the airflow generated by personalized ventilation and the airflow pattern outside...... two occupants was examined using a tracer-gas. Two breathing thermal manikins were used to simulate occupants. The results show that the tested combination of personalized and underfloor ventilation was not able to decrease concentration of the human-produced airborne pollutants in air inhaled...

  4. Evaluation of comfort level in desks equipped with two personalized ventilation systems in slightly warm environments

    Energy Technology Data Exchange (ETDEWEB)

    Conceicao, Eusebio Z.E. [Faculdade de Ciencias e Tecnologia - Universidade do Algarve, Campus de Gambelas, 8005-139 Faro (Portugal); Lucio, Manuela J.R. [Agrupamento Vertical Professor Paula Nogueira, R. Comunidade Lusiada, 8700-000 Olhao (Portugal); Rosa, Silvia P.; Custodio, Ana L.V.; Andrade, Renata L.; Meira, Maria J.P.A. [Faculdade de Ciencias do Mar e do Ambiente - Universidade do Algarve, Campus de Gambelas, 8005-139 Faro (Portugal)

    2010-03-15

    In this work the comfort level, namely the thermal comfort, local thermal discomfort and air quality levels, in a classroom with desks equipped with two personalized ventilation systems, in slightly warm environments, is evaluated. A manikin, a ventilated classroom desk, two indoor climate analyzers, a multi-nodal human thermal comfort numerical model and a computational fluid dynamic numerical model, are used. The classroom desk, with double occupation capacity, is used by a student, located in the right side seat. Each personalized ventilation system is equipped with one air terminal device located above the desk writing area, in front to the trunk area, and an other located below the desk writing area, in front to the legs area. The thermal comfort level is evaluated by the developed multi-nodal human thermal comfort numerical model, using a PMV value, the local thermal discomfort level, namely the draught risk and the air velocity fluctuation equivalent frequencies, is evaluated by empirical models, while the air quality level and the detailed airflow around the manikin are evaluated by the computational fluid dynamic numerical model. In the experimental tests the mean air velocity and the turbulence intensity in the upper air terminal device are 3.5 m/s and 9.7%, while in the lower air terminal device are 2.6 m/s and 15.2%. The mean air temperature in the air terminal devices is around 28 C, while the mean radiant temperature in the occupation area, the mean air temperature far from the occupation area and the internal mean air relative humidity were, respectively, 28 C, 28 C and 50%. The air velocity and temperature around the occupant are measured around 15 human body sections. The actual personalized ventilation system, which promotes an ascendant airflow around the occupant with highest air renovation rate in the respiration area, promotes acceptable thermal comfort conditions and air quality in the respiration area in accord to the present standards. The

  5. The effect of a personalized ventilation system on perceived air quality and SBS symptoms

    DEFF Research Database (Denmark)

    Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor

    2002-01-01

    Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled...... condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p....... Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best...

  6. Grand Theories of Personality Cannot Be Integrated

    Science.gov (United States)

    Wood, Alex; Joseph, Stephen

    2007-01-01

    Comments on the original article "A New Big Five: Fundamental Principles for an Integrative Science of Personality," by Dan P. McAdams and Jennifer L. Pals (see record 2006-03947-002). McAdams and Pals (April 2006) presented a new model to integrate the field of personality psychology. Cultural and evolutionary factors interact with an…

  7. Integrated analysis of numerical weather prediction and computational fluid dynamics for estimating cross-ventilation effects on inhaled air quality inside a factory

    Science.gov (United States)

    Murga, Alicia; Sano, Yusuke; Kawamoto, Yoichi; Ito, Kazuhide

    2017-10-01

    Mechanical and passive ventilation strategies directly impact indoor air quality. Passive ventilation has recently become widespread owing to its ability to reduce energy demand in buildings, such as the case of natural or cross ventilation. To understand the effect of natural ventilation on indoor environmental quality, outdoor-indoor flow paths need to be analyzed as functions of urban atmospheric conditions, topology of the built environment, and indoor conditions. Wind-driven natural ventilation (e.g., cross ventilation) can be calculated through the wind pressure coefficient distributions of outdoor wall surfaces and openings of a building, allowing the study of indoor air parameters and airborne contaminant concentrations. Variations in outside parameters will directly impact indoor air quality and residents' health. Numerical modeling can contribute to comprehend these various parameters because it allows full control of boundary conditions and sampling points. In this study, numerical weather prediction modeling was used to calculate wind profiles/distributions at the atmospheric scale, and computational fluid dynamics was used to model detailed urban and indoor flows, which were then integrated into a dynamic downscaling analysis to predict specific urban wind parameters from the atmospheric to built-environment scale. Wind velocity and contaminant concentration distributions inside a factory building were analyzed to assess the quality of the human working environment by using a computer simulated person. The impact of cross ventilation flows and its variations on local average contaminant concentration around a factory worker, and inhaled contaminant dose, were then discussed.

  8. PERSONALITY THEORY IN INTEGRATIVE PERSONALITY-ORIENTED RECONSTRUCTIVE PSYCHOTHERAPY

    Directory of Open Access Journals (Sweden)

    V I Kurpatov

    2010-01-01

    approaches. V.N. Myasishchev's theory of personality relations in association with its universality, as well as pathogenetic psychotherapy may be the basis for the integration of other methods of psychotherapy

  9. Person-centred care during prolonged weaning from mechanical ventilation, nurses' views: an interview study.

    Science.gov (United States)

    Cederwall, Carl-Johan; Olausson, Sepideh; Rose, Louise; Naredi, Silvana; Ringdal, Mona

    2018-03-19

    To determine: 1) if the three elements of person-centred care (initiating, working and safeguarding the partnership) were present, and 2) to identify evidence of barriers to person-centred care during prolonged weaning from mechanical ventilation. Secondary analysis of semi structured interviews with 19 critical care nurses using theoretical thematic analysis. This study was conducted in three Swedish intensive care units, one in a regional hospital and two in a university hospital. Three themes and nine subthemes related to person-centred care were identified. The three themes included: 1) 'finding a person behind the patient' related to the 'initiating the partnership' phase, 2) 'striving to restore patient́s sense of control' related to 'working the partnership' phase and 3) 'impact of patient involvement' related to 'safeguarding the partnership' phase of person-centred care'. Additionally a further theme 'barriers to person-centred care' was identified. We found evidence of all three person-centred care routines. Barriers to person-centred care comprised of lack team collaboration and resources. Facilitating patients to actively participate in decision-making during the weaning process may optimise weaning outcomes and warrants further research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Energy analysis of the personalized ventilation system in hot and humid climates

    DEFF Research Database (Denmark)

    Schiavon, S.; Melikov, Arsen Krikor; Sekhar, C.

    2010-01-01

    , inhaled air quality, thermal comfort, and self-estimated productivity. Little is known about its energy performance. In this study, the energy consumption of a personalized ventilation system introduced in an office building located in a hot and humid climate (Singapore) has been investigated by means...... effectiveness of PV; (b) increasing the maximum allowed room air temperature due to PV capacity to control the microclimate; (c) supplying the outdoor air only when the occupant is at the desk. The strategy to control the supply air temperature does not affect the energy consumption in a hot and humid climate....

  11. Dispersal of Exhaled Air and Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter Vilhelm

    2002-01-01

    The influence of the human exhalation on flow fields, contaminant distributions, and personal exposures in displacement ventilated rooms is studied together with the effects of physical movement. Experiments are conducted in full-scale test rooms with life-sized breathing thermal manikins....... Numerical simulations support the experiments. Air exhaled through the mouth can lock in a thermally stratified layer, if the vertical temperature gradient in breathing zone height is sufficiently large. With exhalation through the nose, exhaled air flows to the upper part of the room. The exhalation flow...

  12. Experimental investigation on reduced exposure to pollutants indoors by applying wearable personalized ventilation

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho; Melikov, Arsen; Spilak, Michal

    2013-01-01

    of clean air into the breathing zone. Experiments at 23°C (73.4°F) were performed in a full-scale test room with a breathing thermal manikin resembling a seated occupant in a state of thermal comfort, with a realistic free convection flow around the body and breathing cycle. The room air was mixed...... with tracer gas. The personalized ventilation supplied isothermally clean air from circular or elliptical nozzles of different diameters (equivalent diameter: 0.025-0.035 m [0.08-0.12 ft]) positioned near the mouth of the manikin. The enhancement of inhaled air quality was studied by varying the initial...... velocity (0.2-0.6 m/s [0.66- 1.97 fps]), the distance between the nozzles and the mouth (0.02-0.06 m [0.07-0.2 ft]), or the direction of the jet (front, side, or below). The personalized ventilation made it possible to increase up to 94% the portion of clean air into the air inhaled. A wearable...

  13. Use of personalized ventilation for improving health, comfort, and performance at high room temperature and humidity

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Skwarczynski, Mariusz; Kaczmarczyk, J.

    2013-01-01

    in five 4-h experiments in a climate chamber. Under the conditions with PV, the subjects were able to control the rate and direction of the supplied personalized flow of clean air. Subjective responses were collected through questionnaires. During all exposures, the subjects were occupied with tasks used......The effect of personalized ventilation (PV) on people's health, comfort, and performance in a warm and humid environment (26 and 28°C at 70% relative humidity) was studied and compared with their responses in a comfortable environment (23°C and 40% relative humidity). Thirty subjects participated...... to assess their performance. Objective measures of tear film stability, concentration of stress biomarkers in saliva, and eye blinking rate were taken. Using PV significantly improved the perceived air quality (PAQ) and thermal sensation and decreased the intensity of Sick Building Syndrome (SBS) symptoms...

  14. Evaluation of personal integrating dosimeters

    International Nuclear Information System (INIS)

    Correa, C.A.; Bisauta, Mauricio A.

    2007-01-01

    The objective of this work is to analyze the different types of dosimeters present in the international market that are used to provide personal dose monitoring, specifically for external gamma and beta radiation, Hp(10) and Hp (0,07), as well as to add comments of advances in the field of passive and operative dosimetry, and the changes that are being produced in the regulating policy in other countries regarding the use of this devices. The technical specification of each dosimeter has been extracted of different catalogues of products. To conclude, the importance has been stressed in a proper selection of dosimeters with its advantages and disadvantages before its use. (author) [es

  15. Exposure Reduction to Human Bio-effluents Using Seat-integrated Localized Ventilation in Quiescent Indoor Environment

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Rezgals, Lauris; Melikov, Arsen Krikor

    2016-01-01

    Local airflows generated from people such as the natural convection flow may determine the distribution of pollutants indoors. New seat-integrated ventilated method was developed to improve the inhaled air quality of occupants while sitting The method named “Ventilated Cushion” was designed to suck...

  16. Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems

    Science.gov (United States)

    Daniel, Brian A.; Fitzpatrick, Garret R.; Gohmert, Dustin M.; Ybarra, Rick M.; Dub, Mark O.

    2013-01-01

    A document discusses the design and prototype of an advanced spacesuit concept that integrates the capability to function seamlessly with multiple ventilation system approaches. Traditionally, spacesuits are designed to operate both dependently and independently of a host vehicle environment control and life support system (ECLSS). Spacesuits that operate independent of vehicle-provided ECLSS services must do so with equipment selfcontained within or on the spacesuit. Suits that are dependent on vehicle-provided consumables must remain physically connected to and integrated with the vehicle to operate properly. This innovation is the design and prototype of a hybrid spacesuit approach that configures the spacesuit to seamlessly interface and integrate with either type of vehicular systems, while still maintaining the ability to function completely independent of the vehicle. An existing Advanced Crew Escape Suit (ACES) was utilized as the platform from which to develop the innovation. The ACES was retrofitted with selected components and one-off items to achieve the objective. The ventilation system concept was developed and prototyped/retrofitted to an existing ACES. Components were selected to provide suit connectors, hoses/umbilicals, internal breathing system ducting/ conduits, etc. The concept utilizes a lowpressure- drop, high-flow ventilation system that serves as a conduit from the vehicle supply into the suit, up through a neck seal, into the breathing helmet cavity, back down through the neck seal, out of the suit, and returned to the vehicle. The concept also utilizes a modified demand-based breathing system configured to function seamlessly with the low-pressure-drop closed-loop ventilation system.

  17. PATIENT WITH DAMAGED ESPONTANEOUS VENTILATION: AN INTEGRATING REVIEW IN NURSING INTERVENTIONS ON USAGE OF ARTIFICIAL BREATHING

    Directory of Open Access Journals (Sweden)

    Luiz Augusto de Oliveira Antonucci

    2013-10-01

    Full Text Available This study aimed to analyze the nursing interventions given to patients with a diagnosis of spontaneous ventilation in impaired use of artificial respiration. It is an integrative literature review, the databases SciELO, LILACS, BIREME and MEDLINE. We used the key words: Nursing Care; Respiration, Artificial; Intensive Care; Nursing Diagnosis. The sample consisted of 11 items. Of these, ten were equivalent to the care of nursing interventions and suggested priority and/or optional. This study demonstrated that, despite the importance of interventions applied to patients on mechanical ventilation, many are not present in the literature, since this type of patient requires intensive nursing care, extensive and complex. Therefore, we need to encourage nurses to seek evidence to substantiate their clinical practice, providing support for implementation of appropriate interventions, providing the qualification of care.

  18. Airflow characteristics in the breathing zone of a seated person using desk incorporated pair of confluent jets as personalized ventilation - effect of supply velocities

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Nagano, Hideaki; Melikov, Arsen Krikor

    A workplace with desk, desk incorporated personalized ventilation (PV) and a dressed thermal manikin with realistic body and surface temperature distribution were set in a test room (4.70 m x 1.62 m x 2.6 m). 15 L/s were supplied from a ceiling diffuser to ventilate the room at 26 oC air temperat......A workplace with desk, desk incorporated personalized ventilation (PV) and a dressed thermal manikin with realistic body and surface temperature distribution were set in a test room (4.70 m x 1.62 m x 2.6 m). 15 L/s were supplied from a ceiling diffuser to ventilate the room at 26 oC air...... and upwards from the inner jet (closest to manikin) was the same, twice bigger or twice lower compared to that of the outer jet. The mean velocity field at the breathing zone was measured by Particle Image Velocimetry: a dual cavity laser (λ = 532 nm) and a CCD camera - 35 mm lenses. Glycerol droplets...

  19. The integration of engineering and architecture: A perspective on natural ventilation for the new San Francisco Federal Building

    International Nuclear Information System (INIS)

    McConahey, Erin; Haves, Philip; Christ, Tim

    2002-01-01

    A description of the in-progress design of a new Federal Office Building for San Francisco is used to illustrate a number of issues arising in the design of large, naturally ventilated office buildings. These issues include the need for an integrated approach to design involving the architects, mechanical and structural engineers, lighting designers and specialist simulation modelers. In particular, the use of natural ventilation, and the avoidance of air-conditioning, depends on the high degree of exposed thermal mass made possible by the structural scheme and by the minimization of solar heat gains while maintaining the good daylighting that results from optimization of the facade. Another issue was the need for a radical change in interior space planning in order to enhance the natural ventilation; all the individual enclosed offices are located along the central spine of each floorplate rather than at the perimeter. The role of integration in deterring the undermining of the design through value engineering is discussed. The comfort criteria for the building were established based on the recent extension to the ASHRAE comfort standard based on the adaptive model for naturally ventilated buildings. The building energy simulation program EnergyPlus was used to compare the performance of different natural ventilation strategies. The results indicate that, in the San Francisco climate, wind-driven ventilation provides sufficient nocturnal cooling to maintain comfortable conditions and that external chimneys do not provide significant additional ventilation at times when it when it would be beneficial

  20. Predicting adult pulmonary ventilation volume and wearing complianceby on-board accelerometry during personal level exposure assessments

    Science.gov (United States)

    Rodes, C. E.; Chillrud, S. N.; Haskell, W. L.; Intille, S. S.; Albinali, F.; Rosenberger, M. E.

    2012-09-01

    BackgroundMetabolic functions typically increase with human activity, but optimal methods to characterize activity levels for real-time predictions of ventilation volume (l min-1) during exposure assessments have not been available. Could tiny, triaxial accelerometers be incorporated into personal level monitors to define periods of acceptable wearing compliance, and allow the exposures (μg m-3) to be extended to potential doses in μg min-1 kg-1 of body weight? ObjectivesIn a pilot effort, we tested: 1) whether appropriately-processed accelerometer data could be utilized to predict compliance and in linear regressions to predict ventilation volumes in real-time as an on-board component of personal level exposure sensor systems, and 2) whether locating the exposure monitors on the chest in the breathing zone, provided comparable accelerometric data to other locations more typically utilized (waist, thigh, wrist, etc.). MethodsPrototype exposure monitors from RTI International and Columbia University were worn on the chest by a pilot cohort of adults while conducting an array of scripted activities (all volumes in-situ. For the subset of participants with complete data (n = 22), linear regressions were constructed (processed accelerometric variable versus ventilation rate) for each participant and exposure monitor type, and Pearson correlations computed to compare across scenarios. ResultsTriaxial accelerometer data were demonstrated to be adequately sensitive indicators for predicting exposure monitor wearing compliance. Strong linear correlations (R values from 0.77 to 0.99) were observed for all participants for both exposure sensor accelerometer variables against ventilation volume for recumbent, sedentary, and ambulatory activities with MET values ˜volume data. Computing accelerometric standard deviations allowed good sensitivity for compliance assessments even for sedentary activities. These pilot findings supported the hypothesis that a common linear

  1. Wind tunnel study of natural ventilation of building integrated photovoltaics double skin façade

    Directory of Open Access Journals (Sweden)

    Hudişteanu Sebastian Valeriu

    2018-01-01

    Full Text Available The paper presents a wind tunnel experimental analysis of a small-scale building model (1:30. The objective of the study is to determine the wind influence on the ventilation of a double skin façade channel (DSF and the cooling effect over integrated photovoltaic panels. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The effect of the wind over the ventilation of the horizontal channels of double skin façades is evaluated for different incident velocities. The results are generalized for the average steady state values of the velocities analysed. The experimental results put in evidence the correlation between the reference wind velocity and the dynamics of the air movement inside the double skin façade. These values are used to determine the convective heat transfer and the cooling effect of the air streams inside the channel upon the integrated photovoltaic panels. The decrease of the photovoltaic panels temperature determines a raise of 11% in efficiency and power generated.

  2. Wind tunnel study of natural ventilation of building integrated photovoltaics double skin façade

    Science.gov (United States)

    Hudişteanu, Sebastian Valeriu; Popovici, Cătălin George; Cherecheş, Nelu-Cristian

    2018-02-01

    The paper presents a wind tunnel experimental analysis of a small-scale building model (1:30). The objective of the study is to determine the wind influence on the ventilation of a double skin façade channel (DSF) and the cooling effect over integrated photovoltaic panels. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The effect of the wind over the ventilation of the horizontal channels of double skin façades is evaluated for different incident velocities. The results are generalized for the average steady state values of the velocities analysed. The experimental results put in evidence the correlation between the reference wind velocity and the dynamics of the air movement inside the double skin façade. These values are used to determine the convective heat transfer and the cooling effect of the air streams inside the channel upon the integrated photovoltaic panels. The decrease of the photovoltaic panels temperature determines a raise of 11% in efficiency and power generated.

  3. Everyday Cyborgs: On Integrated Persons and Integrated Goods.

    Science.gov (United States)

    Quigley, Muireann; Ayihongbe, Semande

    2018-05-01

    Using the metaphor and actuality of the 'everyday cyborg', this article makes the case that the law is ill-equipped to deal with challenges raised by the linking of the organic, biological person with synthetic, inorganic parts and devices. For instance, should internal medical devices that keep the person alive be viewed as part of the person or mere objects (or something else)? Is damage to neuro-prostheses (eg nervous system integrated limb prostheses) personal injury or damage to property? Who ought to control/own the software in implanted medical devices? And how should the law deal with risks around third-party device access (including that of unauthorised access and hacking)? We argue that satisfactorily answering such questions will likely require a re-analysis of the conceptual and philosophical underpinnings of the law, as well as the law itself. To demonstrate this, we examine the uncharted terrain which everyday cyborgs pose for the law, looking in particular at five areas: (i) medical device regulation, safety, and product liability; (ii) damage to devices and liability; (iii) data and privacy; (iv) security and biohacking; and (v) intellectual property rights. The article highlights how advancing biotechnology continues to reveal, and prompts us to confront, lacunae within the law. Our analysis calls particular attention to law's boundary-work (how the law utilises and incorporates supposed ontological and moral boundaries) and the challenges which everyday cyborgs pose to this.

  4. Learning about ventilators

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000458.htm Learning about ventilators To use the sharing features on this page, ... fixed or changed. How Does Being on a Ventilator Feel? A person receives medicine to remain comfortable ...

  5. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys

    2013-01-01

    The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV...... with air filter and 29 °C with DPV without filter. During the experiments the subjects simulated office work and answered on computerized questionnaires. At warm environment PAQ and air freshness significantly improved when DPV was used. Eye dryness increased significantly with time but was not influenced...... by air temperature and filtering. At 29 °C the facially applied air movement from DPV increased the eye dryness. The SBS symptoms increased with time and were higher (not significantly) at the warm conditions. Air movement did not have profound impact on the SBS symptoms, while filtering had only at 23...

  6. Influence of Restrictive Ventilation Impairment on Physical Function and Activities of Homebound Elderly Persons

    Directory of Open Access Journals (Sweden)

    Jun Horie

    2011-06-01

    Conclusions: Although patients with restrictive ventilation impairment were unlikely to be aware of their disorder, degradation in systemic stamina had already commenced. It appears that maintaining exercise habits prevented degradation of not only instantaneous walking ability but also of systemic stamina.

  7. Performance of Ductless Personalized Ventilation in Open-Plan Office - Field Survey

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Ezzat Khalifa, H.; Melikov, Arsen Krikor

    2013-01-01

    A field survey was conducted in an architectural company located in Syracuse, USA. 54 employees who participated in the survey performed mostly design work. Large open-plan office and several single offices ventilated by displacement air distribution were included in the survey. Ductless...

  8. Personal Exposure Between People in a Room Ventilated by Textile Terminals

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Hyldgård, Carl-Erik; Melikov, Arsen

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized as a displace...

  9. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...

  10. Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Williamson, James [National Renewable Energy Lab. (NREL), Golden, CO (United States); Puttafunta, Srikanth [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-07-30

    One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent

  11. Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, William [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Williamson, James [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-07-01

    One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests that observed temperature, humidity, and pressure conditions through the home and crawlspace.

  12. : ventilators for noninvasive ventilation

    OpenAIRE

    Fauroux , Brigitte; Leroux , Karl; Desmarais , Gilbert; Isabey , Daniel; Clément , Annick; Lofaso , Frédéric; Louis , Bruno

    2008-01-01

    International audience; The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory and expiratory trigger and the ability to reach and maintain the preset pre...

  13. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M.A.; D.A. Springer

    2008-06-18

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the

  14. Ceiling personalized ventilation combined with desk fans for reduced direct and indirect cross-contamination and efficient use of office space

    International Nuclear Information System (INIS)

    Habchi, Carine; Ghali, Kamel; Ghaddar, Nesreen; Chakroun, Walid; Alotaibi, Sorour

    2016-01-01

    Highlights: • Cross-infection occurs by direct inhalation and contact of contaminated surfaces. • Mixing ventilation performance is degraded at reduced distance between occupants. • Ceiling personalized ventilation reduces significantly cross-contamination. • The optimized system induces large energy savings compared to mixing ventilation. • The optimized system improves the occupation density from 12 to 8 m 2 per occupant. - Abstract: Crowded offices with short distances separating workers’ stations increase the probability of respiratory cross-infection via two different paths. One path is the contaminant transmission through air by direct inhalation and the other is through the body contact of contaminated surfaces and walls. Mixed ventilation principles used today reduces the probability of cross contamination by increasing the distance between the stations challenging the efficient use of the space or by supplying more fresh air in the space which is energy inefficient. In this work, new cooling and ventilation configuration is studied by modeling using computational fluid dynamics with consideration of space occupancy density while providing good indoor air quality. The configuration considers a ceiling personalized ventilation system equipped with desk fans. The ability of the computational fluid dynamics model in computing the thermal, velocity and concentration fields was validated by experiments and published data. The main objective of the performed experiments was to ensure that the developed computational fluid dynamics model can capture the effect of the desk fan flow rate on particle behavior. The studied system is found to provide acceptable indoor air quality at shorter distance between the occupants compared to the mixing system at considerable energy savings. By optimizing the design of the proposed personalized ventilation system, the occupancy density in an office is enhanced to 8 m 2 per occupant compared to 12 m 2 per occupant for

  15. Comparative study of cost-benefit integrated system of water spary with industrial ventilation and bag filters in a minerals processing company

    Directory of Open Access Journals (Sweden)

    Morteza Babaei

    2016-06-01

    Full Text Available Introduction: Control of fugitative dust from mining process and application of an appropriate and economical system for dust collecting is essential. The goal of this study was cost-benefit analysis of an integrated systems and compare to bag filter in a crushing plant of a mining company. Methods: A local exhaust ventilation system for capture of emitted particlees, a water spray for dust suppresion at sources and parallel Stairmand model cyclones as dust colletor were designed and installed based on the standards and guidelines. Then, efficiency of wetting and industrial ventilation system for control of ambient dust personal exposure and environmental emission have evaluated as integrated and alone. Finally, cost-benefit analysis of this system was compared to bag filter. Results: The efficiency of this system for control personal exposure repairable particles and emitted dust to ambient air was 87% and 95% for plant 1 and 88% and 95% for plant 2, respectively. The concentration of emitted emitted dust from stack to environment were 121.28 mg/m3 and 112/68 mg/m3 for plant 1 and 2, respectively. The capital, operational and maintence costs of this option was 217 and 0.992 billion rials lower than bag filter. Also, annuall collected dust by cyclones was worth 518 million rial. Conclusion: According to results, integrated system had a significant impact on emitted dust in workplace and environment. The economical analysis domonstrated 73% and 80% savings in capital and operational costs compared to bag filter. Total costs of implented project will be compensated at 220 day with recovered dusts, therefore, in the same condition, it can be suggested as the favourable and economical solution.

  16. The Psychosocial Integration of Seropositive Persons

    Directory of Open Access Journals (Sweden)

    Matei Raluca

    2017-05-01

    Full Text Available We can assume without fail that the psychosocial implications in case of HIV/AIDS are as overwhelming as the medical aspects. For the positive person as well as for those who assist the seropositive people, the uncertainty frames the medical prognosis. All the effects that occur are entirely funded: the loss of self-trust as well as mistrusting others, stigmatization, isolation, getting abandoned by the family, friends, neighbors and school mates or coworkers. The current study aims to evaluate this aspect, the fact that the living environment of the seropositive person does not lead to significant differences as far as adjusting to HIV/AIDS diagnosis is concerned, but the adjusting differences are more related to the personality structure of the infected person, to the way this person identifies strategies of coping with the new situations he / she has to deal with (cognitive, emotional and behavioral strategies. In the applicative part of the study, we analyze the adjustment to the diagnosis, as well as the adherence to the treatment, by applying certain specific work instruments.

  17. Control of the Free Convective Flow around the Human Body for Enhanced Inhaled Air Quality: Application to a Seat-Incorporated Personalized Ventilation Unit

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Krenek, M.

    2010-01-01

    This paper reports on methods for control of the free convective flow around the human body, with the aim of improving inhaled air quality. The methods were studied with sea-incorporated personalized ventilation (PV)-two PV nozzles placed sideways at the head level of a seated occupant supplied...

  18. Content-Based Personalization Services Integrating Folksonomies

    Science.gov (United States)

    Musto, Cataldo; Narducci, Fedelucio; Lops, Pasquale; de Gemmis, Marco; Semeraro, Giovanni

    Basic content-based personalization consists in matching up the attributes of a user profile, in which preferences and interests are stored, with the attributes of a content object. The Web 2.0 (r)evolution has changed the game for personalization, from ‘elitary’ Web 1.0, written by few and read by many, to web content generated by everyone (user-generated content - UGC), since the role of people has evolved from passive consumers of information to that of active contributors.

  19. Seat-integrated localized ventilation for exposure reduction to air pollutants in indoor environments

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Rezgals, Lauris; Melikov, Arsen Krikor

    2016-01-01

    A novel ventilation method for minimizing the spread of bioeffluent contaminants generated from sedentary people indoors was developed and studied. The concept of the method consists of a ventilated cushion which is able to suck the human bioeffluents at the area of the body where they are mainly...... generated before they disperse around a room. The polluted near the body air is exhausted into the cushion and it is removed from the room by a separate exhaust system. The performance of the method was studied in series of experiments. Full-scale room and a dressed thermal manikin sitting in front....... The experiments were conducted at 26°C room air temperature. The performance of the VC in conjunction with mixing total-volume background ventilation at 1 air change per hour (ACH) was compared with that of mixing background ventilation alone operating at 1, 1.5, 3 and 6 ACH. Experiments at exhaust airflow rate...

  20. An Integrative Dimensional Classification of Personality Disorder

    Science.gov (United States)

    Widiger, Thomas A.; Livesley, W. John; Clark, Lee Anna

    2009-01-01

    Psychological assessment research concerns how to describe psychological dysfunction in ways that are both valid and useful. Recent advances in assessment research hold the promise of facilitating significant improvements in description and diagnosis. One such contribution is in the classification of personality disorder symptomatology. The…

  1. Intraoperative mechanical ventilation for the pediatric patient.

    Science.gov (United States)

    Kneyber, Martin C J

    2015-09-01

    Invasive mechanical ventilation is required when children undergo general anesthesia for any procedure. It is remarkable that one of the most practiced interventions such as pediatric mechanical ventilation is hardly supported by any scientific evidence but rather based on personal experience and data from adults, especially as ventilation itself is increasingly recognized as a harmful intervention that causes ventilator-induced lung injury. The use of low tidal volume and higher levels of positive end-expiratory pressure became an integral part of lung-protective ventilation following the outcomes of clinical trials in critically ill adults. This approach has been readily adopted in pediatric ventilation. However, a clear association between tidal volume and mortality has not been ascertained in pediatrics. In fact, experimental studies have suggested that young children might be less susceptible to ventilator-induced lung injury. As such, no recommendations on optimal lung-protective ventilation strategy in children with or without lung injury can be made. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Predicting the Air Quality, Thermal Comfort and Draught Risk for a Virtual Classroom with Desk-Type Personalized Ventilation Systems

    Directory of Open Access Journals (Sweden)

    Eusébio Z. E. Conceição

    2018-02-01

    Full Text Available This paper concerns the prediction of indoor air quality (IAQ, thermal comfort (TC and draught risk (DR for a virtual classroom with desk-type personalized ventilation system (PVS. This numerical study considers a coupling of the computational fluid dynamics (CFD, human thermal comfort (HTC and building thermal behavior (BTB numerical models. The following indexes are used: the predicted percentage of dissatisfied people (PPD index is used for the evaluation of the TC level; the carbon dioxide (CO2 concentration in the breathing zone is used for the calculation of IAQ; and the DR level around the occupants is used for the evaluation of the discomfort due to draught. The air distribution index (ADI, based in the TC level, the IAQ level, the effectiveness for heat removal and the effectiveness for contaminant removal, is used for evaluating the performance of the personalized air distribution system. The numerical simulation is made for a virtual classroom with six desks. Each desk is equipped with one PVS with two air terminal devices located overhead and two air terminal devices located below the desktop. In one numerical simulation six occupants are used, while in another simulation twelve occupants are considered. For each numerical simulation an air supply temperature of 20 °C and 24 °C is applied. The results obtained show that the ADI value is higher for twelve persons than for six persons in the classroom and it is higher for an inlet air temperature of 20 °C than for an inlet air temperature of 24 °C. In future works, more combinations of upper and lower air terminal devices located around the body area and more combinations of occupants located in the desks will be analyzed.

  3. Ventilation systems

    International Nuclear Information System (INIS)

    Gossler

    1980-01-01

    The present paper deals with - controlled area ventilation systems - ventilation systems for switchgear-building and control-room - other ventilation systems for safety equipments - service systems for ventilation systems. (orig./RW)

  4. Mechanical Ventilation

    Science.gov (United States)

    ... ventilation is a life support treatment. A mechanical ventilator is a machine that helps people breathe when ... to breathe enough on their own. The mechanical ventilator is also called a ventilator , respirator, or breathing ...

  5. Wearable Personal Exhaust Ventilation, WPEV: Improved Indoor Air Quality and Reduced Exposure to Air Exhaled from a Sick Doctor

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho D.; Barova, Maria; Melikov, Arsen K.

    2015-01-01

    pause) and a tidal flow rate of 6 L/min. A second thermal manikin and heated dummy were used to resemble lying patients. Exhaled air by the doctor was mixed with tracer gas to mimic pathogens. The wearable personal exhaust unit was positioned frontally by the mouth of the doctor at three distances: 0.......02, 0.04, and 0.06 m. It was operated at 0.25 or 0.50 L/s under mixing background ventilation at three air changes per hour. The effect of the wearable exhaust unit geometry by modifying the exhaust surface, as well as the posture of the doctor, standing or seated, was also studied. The use...... of the wearable personal exhaust resulted in cleaner air in the room compared to mixing alone at 12 air changes per hour, reducing the exposure of the two patients. The nozzle geometry and posture of the doctor affected the indoor exposure to exhaled air. The high potential to capture exhaled air makes the device...

  6. Integrative Treatment of Personality Disorder. Part I: Psychotherapy.

    Science.gov (United States)

    Jovanovic, Mirjana Divac; Svrakic, Dragan

    2017-03-01

    In this paper, we outline the concept of integrative therapy of borderline personality, also referred to as fragmented personality, which we consider to be the core psychopathology underlying all clinical subtypes of personality disorder. Hence, the terms borderline personality, borderline disorder, fragmented personality, and personality disorder are used interchangeably, as synonyms. Our integrative approach combines pharmacotherapy and psychotherapy, each specifically tailored to accomplish a positive feedback modulation of their respective effects. We argue that pharmacotherapy and psychotherapy of personality disorder complement each other. Pharmacological control of disruptive affects clears the stage, in some cases builds the stage, for the psychotherapeutic process to take place. In turn, psychotherapy promotes integration of personality fragments into more cohesive structures of self and identity, ultimately establishing self-regulation of mood and anxiety. We introduce our original method of psychotherapy, called reconstructive interpersonal therapy (RIT). The RIT integrates humanistic-existential and psychodynamic paradigms, and is thereby designed to accomplish a deep reconstruction of core psychopathology within the setting of high structure. We review and comment the current literature on the strategies, goals, therapy process, priorities, and phases of psychotherapy of borderline disorders, and describe in detail the fundamental principles of RIT.

  7. Personal Integration Resources of Mentally Handicapped Teenagers into Society

    Science.gov (United States)

    Konovalova, Natalia

    2016-01-01

    The paper deals with the issues concerning the study of mentally handicapped teenagers' integrative potential within modernisation of contemporary Russian education. The research is concentrated on the study of personal and social determinants influencing the readiness of mentally handicapped students to be integrated into the environment.…

  8. Modelling the heat dynamics of building integrated and ventilated photovoltaic modules

    DEFF Research Database (Denmark)

    Friling, N.; Jimenez, M.J.; Bloem, H.

    2009-01-01

    the heat transfer from the PV module. The experiment and data originate from a test reference module the EC-JRC Ispra. The set-up provides the opportunity of changing physical parameters, the ventilation speed and the type of air flow, and this makes it possible to determine the preferable set......, are applied in the set-up combined with high level of air flow. The improved description by the model is mainly seen in periods with high solar radiation....

  9. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large ......-uniformity air distribution and further led to the draught problem in the occupied zone. This system was recommended to apply in the small offices instead of large, open spaces....

  10. Psychotherapy integration in the treatment of personality disorders: a commentary.

    Science.gov (United States)

    Nelson, Dana L; Beutler, Larry E; Castonguay, Louis G

    2012-02-01

    Whereas research on the treatment of personality disorders over the past several decades has focused primarily on comparing the efficacy of various treatment packages associated with different theoretical models, there is increasing evidence that the field would benefit from focusing more attention on developing integrative treatments that are both informed by research and capable of scientific verification. The articles assembled for this special section each propose a different approach to integrative treatment for personality disorders. In this commentary, we outline a number of reasons for making such a shift to more integrative treatments, consider some of the potential challenges to integration, and discuss the different approaches to integration illustrated in these articles. We highlight some of the difficult tradeoffs that must be made in developing an integrative approach and discuss similarities and differences in the response to such challenges by the contributors to this special section. Finally, we point to several areas for future research that we believe will contribute to the development of increasingly effective treatments for individuals with personality disorders.

  11. Safety demonstration tests on pressure rise in ventilation system and blower integrity of a fuel-reprocessing plant

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Junichi; Suzuki, Motoe; Tsukamoto, Michio; Koike, Tadao; Nishio, Gunji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    In JAERI, the demonstration test was carried out as a part of safety researches of the fuel-reprocessing plant using a large-scale facility consist of cells, ducts, dumpers, HEPA filters and a blower, when an explosive burning due to a rapid reaction of thermal decomposition for solvent/nitric acid occurs in a cell of the reprocessing plant. In the demonstration test, pressure response propagating through the facility was measured under a blowing of air from a pressurized tank into the cell in the facility to elucidate an influence of pressure rise in the ventilation system. Consequently, effective pressure decrease in the facility was given by a configuration of cells and ducts in the facility. In the test, transient responses of HEPA filters and the blower by the blowing of air were also measured to confirm the integrity. So that, it is confirmed that HEPA filters and the blower under pressure loading were sufficient to maintain the integrity. The content described in this report will contribute to safety assessment of the ventilation system in the event of explosive burning in the reprocessing plant. (author)

  12. Meaning in life of older persons : An integrative literature review

    NARCIS (Netherlands)

    MSc S.H.A. Hupkens; Anja Machielse; Dr. M.J.B.M. Goumans; P. Derkx

    2016-01-01

    The aim of this integrative review for nurses is to synthesize knowledge from scholarly literature to provide insight into how older persons find meaning in life, what are influencing circumstances, and what are their sources of meaning. The review serves as a starting point for including meaning in

  13. A naturally ventilated accumulator for integrating measurements of radon flux from soil

    International Nuclear Information System (INIS)

    Zhuo Weihai; Furukawa, Masahide; Tokonami, Shinji

    2007-01-01

    For long-term and large-scale measurements of the averaged 222 Rn fluxes from soils in the general environmental conditions, a simple measuring method was developed. 222 Rn exhaling from soils is accumulated by a naturally ventilated accumulator (NVA) and its concentration is measured with passive 222 Rn monitors set inside the NVA. The ventilation rate of the NVA is about 0.26 h -1 and it is hardly affected by the changes of meteorological conditions during field measurements. The air and soil conditions inside and outside of the NVA are nearly the same throughout the measurements. It indicates that the natural conditions of soils will not be significantly disturbed by the NVA. Field measurements confirmed that soil 222 Rn fluxes measured by the new method were in general agreement with the results measured by another commonly used method and theoretical estimations. As no electric power is needed as well as the operation and maintenance are easy, the low-cost system offers a promise as an improved technique for long-term measurements of soil 222 Rn fluxes in the general environmental conditions. (author)

  14. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  15. Microblogging for Class: An Analysis of Affective, Cognitive, Personal Integrative, and Social Integrative Gratifications

    Science.gov (United States)

    Gant, Camilla; Hadley, Patrick D.

    2014-01-01

    This study shows that undergraduate students can gratify cognitive, affective, social integrative, and personal integrative needs microblogging via a learning management system discussion tool. Moreover, the researchers find that microblogging about news regarding mass media events and issues via Blackboard heightened engagement, expanded…

  16. Digital Technologies Supporting Person-Centered Integrated Care - A Perspective.

    Science.gov (United States)

    Øvretveit, John

    2017-09-25

    Shared electronic health and social care records in some service systems are already showing some of the benefits of digital technology and digital data for integrating health and social care. These records are one example of the beginning "digitalisation" of services that gives a glimpse of the potential of digital technology and systems for building coordinated and individualized integrated care. Yet the promise has been greater than the benefits, and progress has been slow compared to other industries. This paper describes for non-technical readers how information technology was used to support integrated care schemes in six EU services, and suggests practical ways forward to use the new opportunities to build person-centered integrated care.

  17. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  18. The integrity of persons elected, appointed or exercising public functions

    Directory of Open Access Journals (Sweden)

    Agathi Nano

    2017-07-01

    On 17 December 2015, Members of the Albanian Parliament adopt by consensus the constitutional amendments and legislative framework which are necessary to introduce in our country a clear mechanism for the exclusion of criminal offenders from public offices. In this paper we examine regulatory issues relating to the legal framework necessary to guarantee the integrity of public officials, the verification and ascertainment of the prohibition of exercising public functions and the implementation of the prohibitive measures provided for by law no. 138/2015 “On guaranteeing the integrity of the persons elected and/or appointed to, or exercising public functions”, the so called “decriminalisation” law.

  19. Application of local exhaust ventilation system and integrated collectors for control of air pollutants in mining company.

    Science.gov (United States)

    Ghorbani Shahna, Farshid; Bahrami, Abdulrahman; Farasati, Farhad

    2012-01-01

    Local exhaust ventilation (LEV) systems and integrated collectors were designed and implemented in a mining company in order to control emitted air pollutant from furnaces. The LEV was designed for capture and transition of air pollutants emitted from furnaces to the integrated collectors. The integrated collectors including four high efficiency Stairmand model cyclones for control of particulate matter, a venturi scrubber for control of the fine particles, SO(2) and a part of H(2)S to follow them, and a packed scrubber for treatment of the residual H(2)S and SO(2) were designed. Pollutants concentration were measured to determine system effectiveness. The results showed that the effectiveness of LEV for reducing workplace pollution is 91.83%, 96.32% and 83.67% for dust, SO(2) and H(2)S, respectively. Average removal efficiency of particles by combination of cyclone and venturi scrubber was 98.72%. Average removal efficiency of SO(2) and H(2)S were 95.85% and 47.13% for the venturi scrubber and 68.45% and 92.7% for the packed bed scrubber. The average removal efficiency of SO(2) and H(2)S were increased to 99.1% and 95.95% by the combination of venturi and packed bed scrubbers. According to the results, integrated collectors are a good air pollution control option for industries with economic constraints and ancient technologies.

  20. Protection Against Cross Infection in Hospital Beds with Integrated Personalized Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Polak, Marcin; Jiang, Hao

    2008-01-01

    in this paper are carried out with tracer gas and two thermal manikins in the experimental SARS ward at Hong Kong University. One of the manikins is the source manikin, and the other one the target. The measurements show that a very high degree of protection can be obtained with this system. Optimum flow rate...... and temperature of the supply air are addressed in the research work....

  1. The Influence of Draught on a Seat with Integrated Personalized Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Barszcz, Ewa; Czarnota, Tomasz

    2008-01-01

    in this process are very small and draught may be able to disturb the process. Therefore, this research work deals with the effectiveness of the system with different levels and directions of draught. The measurements are made with a full-scale manikin in a wind tunnel. The results show that the boundary layer...... and the process in the breathing zone are rather independent of draught at velocities up to 0.2 m/s....

  2. VENTILATION MODEL

    International Nuclear Information System (INIS)

    V. Chipman

    2002-01-01

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their postclosure analyses

  3. Ventilation models

    Science.gov (United States)

    Skaaret, Eimund

    Calculation procedures, used in the design of ventilating systems, which are especially suited for displacement ventilation in addition to linking it to mixing ventilation, are addressed. The two zone flow model is considered and the steady state and transient solutions are addressed. Different methods of supplying air are discussed, and different types of air flow are considered: piston flow, plane flow and radial flow. An evaluation model for ventilation systems is presented.

  4. Industrial ventilation

    Science.gov (United States)

    Goodfellow, H. D.

    Industrial ventilation design methodology, using computers and using fluid dynamic models, is considered. It is noted that the design of a ventilation system must be incorporated into the plant design and layout at the earliest conceptual stage of the project. A checklist of activities concerning the methodology for the design of a ventilation system for a new facility is given. A flow diagram of the computer ventilation model shows a typical input, the initialization and iteration loop, and the output. The application of the fluid dynamic modeling techniques include external and internal flow fields, and individual sources of heat and contaminants. Major activities for a ventilation field test program are also addressed.

  5. Integrated smart control of heating, cooling, ventilation, daylighting and electrical lighting in buildings

    NARCIS (Netherlands)

    Bakker, L.G.; Brouwer, A.H.M.; Babuska, R.

    1998-01-01

    The present energy consumption of European Buildings is higher than necessary, given the developments in control engineering. Optimization and integration of smart control into building systems can save substantial quantities of energy on a European scale while improving the standards for indoor

  6. Professional formation through personal involvement and value integration.

    Science.gov (United States)

    Haugland, Britt Øvrebø; Lassen, Rasmus M; Giske, Tove

    2018-03-01

    Formation is an important part of nursing education, and it is the responsibility of nurse educators to facilitate learning situations that provide students with opportunities for personal discovery. Studies have shown that awareness of one's own vulnerability can be a source of professional maturation and courageous action. The study setting is a Christian university that emphasises its value base through the perspective of diakonia in the nursing programme. Diakonia is understood as the provision of caring. Two hundred and forty-five pages of reflective journals from 124 third-year students were analysed with qualitative content analysis. The main theme of the study was Professional formation through personal involvement and value integration. Four categories emerged: 1) Diakonia as a guide to professional compassion; 2) Consciousness of one's own values; 3) The urge to act courageously; and 4) Choosing to spend the time available. The article discusses how students can integrate values in their professional lives by using all senses when learning in real-life situations and by using systematic reflection alone and together with others. Professional formation is an ongoing process, and we have found that mandatory participation, reiteration and progression are important conditions for such formation to occur. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. [Integrative approach in the psychotherapy of borderline personality disorder].

    Science.gov (United States)

    Kuritárné Szabó, Ildikó

    2012-01-01

    In the last 20 years six psychotherapy methods have been developed specifically for borderline personality disorder. Solid RCT evidences suggests the efficacy of all the methods. Roughly equivalent improvement was obtained from the different types of psychotherapies. Today we have reached a new phase of the borderline "psychotherapy boom", the integrative approach. According to the integrative treatment advocates we should not choose among these effective treatments but we can incorporate in the therapy all the components that work. The integrative approach uses general factors common to all effective therapies, combined with specific treatment techniques taken from different therapies in order to treat the given patient's psychopathology. These common factors are: coherent framework; attention to strategies for building strong positive alliance and maintaining patient motivation; creating a safe and structured therapeutic environment; clear treatment frame; transparency of the goals and roles; focus upon presenting problems; higher level therapeutic activity; here-and-now focus; and facilitating self-reflection. Treatment focuses on change while maintaining a validating and supportive stance. General strategies can be supplemented by more specific techniques such as cognitive-behavioral interventions for reducing maladaptive behavior, training for developing emotion regulation skills and interpersonal skills coming from dialectical behavior therapy. Methods drawn from psychodynamic approaches can be used for the modification of underlying interpersonal cognitive-emotional schemas.

  8. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  9. Work and personal life boundary management: boundary strength, work/personal life balance, and the segmentation-integration continuum.

    Science.gov (United States)

    Bulger, Carrie A; Matthews, Russell A; Hoffman, Mark E

    2007-10-01

    While researchers are increasingly interested in understanding the boundaries surrounding the work and personal life domains, few have tested the propositions set forth by theory. Boundary theory proposes that individuals manage the boundaries between work and personal life through processes of segmenting and/or integrating the domains. The authors investigated boundary management profiles of 332 workers in an investigation of the segmentation-integration continuum. Cluster analysis indicated consistent clusters of boundary management practices related to varying segmentation and integration of the work and personal life domains. But, the authors suggest that the segmentation-integration continuum may be more complicated. Results also indicated relationships between boundary management practices and work-personal life interference and work-personal life enhancement. Less flexible and more permeable boundaries were related to more interference, while more flexible and more permeable boundaries were related to more enhancement.

  10. Mine ventilation engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hall, C.J.

    1981-01-01

    This book on mine ventilation covers psychometrics, airflow through roadways and ducts, natural ventilation, fans, instruments, ventilation surveys, auxiliary ventilation, air quality, and planning and economics.

  11. Noninvasive ventilation.

    Science.gov (United States)

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  12. Ventilation effectiveness

    CERN Document Server

    Mathisen, Hans Martin; Nielsen, Peter V; Moser, Alfred

    2004-01-01

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy-to-understand descriptions of the indices used to mesure the performance of a ventilation system and which indices to use in different cases.

  13. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  14. Demand Controlled Ventilation and Classroom Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  15. Demand controlled ventilation and classroom ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-06

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  16. Ventilation Effectiveness

    DEFF Research Database (Denmark)

    Mundt, M.; Mathisen, H. M.; Moser, M.

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy-to-un...

  17. Behovstyret ventilation

    DEFF Research Database (Denmark)

    Afshari, Alireza; Heiselberg, Per; Reinhold, Claus

    2010-01-01

    I en nylig afsluttet undersøgelse er der udført en række målinger på otte udvalgte børneinstitutioner. Fire af disse med mekanisk ventilation og fire med naturlig ventilation. Formålet er at udvide den erfaringsbaserede viden om funktionen af naturlige og mekaniske ventilationsløsninger i...

  18. Ventilation Model

    International Nuclear Information System (INIS)

    Yang, H.

    1999-01-01

    The purpose of this analysis and model report (AMR) for the Ventilation Model is to analyze the effects of pre-closure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts and provide heat removal data to support EBS design. It will also provide input data (initial conditions, and time varying boundary conditions) for the EBS post-closure performance assessment and the EBS Water Distribution and Removal Process Model. The objective of the analysis is to develop, describe, and apply calculation methods and models that can be used to predict thermal conditions within emplacement drifts under forced ventilation during the pre-closure period. The scope of this analysis includes: (1) Provide a general description of effects and heat transfer process of emplacement drift ventilation. (2) Develop a modeling approach to simulate the impacts of pre-closure ventilation on the thermal conditions in emplacement drifts. (3) Identify and document inputs to be used for modeling emplacement ventilation. (4) Perform calculations of temperatures and heat removal in the emplacement drift. (5) Address general considerations of the effect of water/moisture removal by ventilation on the repository thermal conditions. The numerical modeling in this document will be limited to heat-only modeling and calculations. Only a preliminary assessment of the heat/moisture ventilation effects and modeling method will be performed in this revision. Modeling of moisture effects on heat removal and emplacement drift temperature may be performed in the future

  19. Self-regulation underlies temperament and personality : An integrative developmental framework

    NARCIS (Netherlands)

    Denissen, J.J.A.; van Aken, M.A.G.; Penke, L.; Wood, D.

    2013-01-01

    In this article, we present an integrative perspective on temperament and personality development. Personality and temperament are conceptualized as regulatory systems that start as physiological reactivity to environmental features early in life, but are increasingly supplemented by regulation

  20. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  1. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state......-of-the-art of ventilative cooling potentials and limitations, its consideration in current energy performance regulations, available building components and control strategies and analysis methods and tools. In addition, the report provides twenty six examples of operational buildings using ventilative cooling ranging from...

  2. A novel personal cooling system (PCS) incorporated with phase change materials (PCMs) and ventilation fans: An investigation on its cooling efficiency.

    Science.gov (United States)

    Lu, Yehu; Wei, Fanru; Lai, Dandan; Shi, Wen; Wang, Faming; Gao, Chuansi; Song, Guowen

    2015-08-01

    Personal cooling systems (PCS) have been developed to mitigate the impact of severe heat stress for humans working in hot environments. It is still a great challenge to develop PCSs that are portable, inexpensive, and effective. We studied the performance of a new hybrid PCS incorporating both ventilation fans and phase change materials (PCMs). The cooling efficiency of the newly developed PCS was investigated on a sweating manikin in two hot conditions: hot humid (HH, 34°C, 75% RH) and hot dry (HD, 34°C, 28% RH). Four test scenarios were selected: fans off with no PCMs (i.e., Fan-off, the CONTROL), fans on with no PCMs (i.e., Fan-on), fans off with fully solidified PCMs (i.e., PCM+Fan-off), and fans on with fully solidified PCMs (i.e., PCM+Fan-on). It was found that the addition of PCMs provided a 54∼78min cooling in HH condition. In contrast, the PCMs only offered a 19-39min cooling in HD condition. In both conditions, the ventilation fans greatly enhanced the evaporative heat loss compared with Fan-off. The hybrid PCS (i.e., PCM+Fan-on) provided a continuous cooling effect during the three-hour test and the average cooling rate for the whole body was around 111 and 315W in HH and HD conditions, respectively. Overall, the new hybrid PCS may be an effective means of ameliorating symptoms of heat stress in both hot-humid and hot-dry environments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making.

    Science.gov (United States)

    Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J

    2015-08-01

    Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Performance of radiant cooling ceiling combined with personalized ventilation in an office room: identification of thermal conditions

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    were performed in a test room arranged as an office with 2 workstations and 2 seating occupants resembled by thermal manikins. Heat gain of 66-72 W/m2 was simulated in the room (occupants, computers, lighting, solar gain). The air temperature in the chamber was maintained at 26°C and 28°C. Personalized...

  5. Personality Facets and RIASEC Interests: An Integrated Model

    Science.gov (United States)

    Armstrong, Patrick Ian; Anthoney, Sarah Fetter

    2009-01-01

    Research examining links between personality and interest have typically focused on links between measures of the five factor model and Holland's RIASEC types. However, the five factor model of personality can be divided in to a larger set of narrow domain personality scales measuring facets of the "big five" traits. Research in a number of fields…

  6. 46 CFR 194.10-25 - Ventilation.

    Science.gov (United States)

    2010-10-01

    ... magazines. (1) All integral magazines shall be provided with natural or mechanical ventilation. Design... vans shall be provided with natural ventilation sufficient to maintain the inside air temperature below... 46 Shipping 7 2010-10-01 2010-10-01 false Ventilation. 194.10-25 Section 194.10-25 Shipping COAST...

  7. Integrating Early Intervention for Borderline Personality Disorder and Mood Disorders.

    Science.gov (United States)

    Chanen, Andrew M; Berk, Michael; Thompson, Katherine

    2016-01-01

    Borderline personality disorder (BPD) has been demonstrated to be a reliable and valid construct in young people (adolescents and young adults). Both borderline- and mood-related psychopathology become clinically apparent from puberty through to young adulthood, frequently co-occur, can reinforce one another, and can be difficult to differentiate clinically. This Gordian knot of overlapping clinical features, common risk factors, and precursors to both BPD and mood disorders complicates clinical assessment, prevention, and treatment. Regardless of whether an individual crosses an arbitrary diagnostic threshold, a considerable proportion of young people with borderline- and mood-related psychopathology will develop significant and persistent functional, vocational, and interpersonal impairment and disability during this critical risk and developmental period. There is a clear need for early intervention, but spurious diagnostic certainty risks stigma, misapplication of diagnostic labels, inappropriate treatment, and unfavorable outcomes. This article aims to integrate early intervention for BPD and mood disorders in the clinical context of developmental and phenomenological change and evolution. "Clinical staging," similar to disease staging in general medicine, is presented as a pragmatic, heuristic, and trans-diagnostic framework to guide prevention and intervention. It acknowledges that the early stages of these disorders cannot be disentangled sufficiently to allow for disorder-specific preventive measures and early interventions. Clinical staging defines an individual's location along the continuum of the evolving temporal course of a disorder. Such staging aids differentiation of early or milder clinical phenomena from those that accompany illness progression and chronicity, and suggests the application of appropriate and proportionate intervention strategies.

  8. CFD and Ventilation Research

    DEFF Research Database (Denmark)

    Li, Y.; Nielsen, Peter V.

    2011-01-01

    There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part...... of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize...... the growing need for CFD verification and validation, suggest on-going needs for analytical and experimental methods to support the numerical solutions, and discuss the growing capacity of CFD in opening up new research areas. We suggest that CFD has not become a replacement for experiment and theoretical...

  9. Liquid ventilation.

    Science.gov (United States)

    Sarkar, Suman; Paswan, Anil; Prakas, S

    2014-01-01

    Human have lungs to breathe air and they have no gills to breath liquids like fish. When the surface tension at the air-liquid interface of the lung increases as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV) is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen as the inert carrier of oxygen and carbon dioxide offers a number of advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. It is well-known that respiratory diseases are one of the most common causes of morbidity and mortality in intensive care unit. During the past few years several new modalities of treatment have been introduced. One of them and probably the most fascinating, is of LV. Partial LV, on which much of the existing research has concentrated, requires partial filling of lungs with perfluorocarbons (PFC's) and ventilation with gas tidal volumes using conventional mechanical ventilators. Various physico-chemical properties of PFC's make them the ideal media. It results in a dramatic improvement in lung compliance and oxygenation and decline in mean airway pressure and oxygen requirements. No long-term side-effect reported.

  10. Delineating the Structure of Normal and Abnormal Personality: An Integrative Hierarchical Approach

    Science.gov (United States)

    Markon, Kristian E.; Krueger, Robert F.; Watson, David

    2008-01-01

    Increasing evidence indicates that normal and abnormal personality can be treated within a single structural framework. However, identification of a single integrated structure of normal and abnormal personality has remained elusive. Here, a constructive replication approach was used to delineate an integrative hierarchical account of the structure of normal and abnormal personality. This hierarchical structure, which integrates many Big Trait models proposed in the literature, replicated across a meta-analysis as well as an empirical study, and across samples of participants as well as measures. The proposed structure resembles previously suggested accounts of personality hierarchy and provides insight into the nature of personality hierarchy more generally. Potential directions for future research on personality and psychopathology are discussed. PMID:15631580

  11. Delineating the structure of normal and abnormal personality: an integrative hierarchical approach.

    Science.gov (United States)

    Markon, Kristian E; Krueger, Robert F; Watson, David

    2005-01-01

    Increasing evidence indicates that normal and abnormal personality can be treated within a single structural framework. However, identification of a single integrated structure of normal and abnormal personality has remained elusive. Here, a constructive replication approach was used to delineate an integrative hierarchical account of the structure of normal and abnormal personality. This hierarchical structure, which integrates many Big Trait models proposed in the literature, replicated across a meta-analysis as well as an empirical study, and across samples of participants as well as measures. The proposed structure resembles previously suggested accounts of personality hierarchy and provides insight into the nature of personality hierarchy more generally. Potential directions for future research on personality and psychopathology are discussed.

  12. Personality and recovery: integrating personality assessment data to facilitate the recovery process.

    Science.gov (United States)

    Donat, D C

    2001-01-01

    The relatively enduring and persistent nature of personality traits means that they will likely continue to impact the course of psychiatric recovery after Axis I symptoms are stabilized. These traits can significantly impact the choices that recovering persons make and the quality of interpersonal relationships with care providers who are trying to facilitate the recovery process. Despite this, they are often inadequately assessed and considered in providing psychiatric care. This manuscript reviews the common combinations of personality traits that have emerged across a variety of clinical samples. The implications of these personality features for the provision of care in an inpatient setting to facilitate recovery are discussed.

  13. Mixing Ventilation

    DEFF Research Database (Denmark)

    Kandzia, Claudia; Kosonen, Risto; Melikov, Arsen Krikor

    In this guidebook most of the known and used in practice methods for achieving mixing air distribution are discussed. Mixing ventilation has been applied to many different spaces providing fresh air and thermal comfort to the occupants. Today, a design engineer can choose from large selection...

  14. The Integration of Personal Learning Environments & Open Network Learning Environments

    Science.gov (United States)

    Tu, Chih-Hsiung; Sujo-Montes, Laura; Yen, Cherng-Jyh; Chan, Junn-Yih; Blocher, Michael

    2012-01-01

    Learning management systems traditionally provide structures to guide online learners to achieve their learning goals. Web 2.0 technology empowers learners to create, share, and organize their personal learning environments in open network environments; and allows learners to engage in social networking and collaborating activities. Advanced…

  15. Understanding Personality Development: An Integrative State Process Model

    Science.gov (United States)

    Geukes, Katharina; van Zalk, Maarten; Back, Mitja D.

    2018-01-01

    While personality is relatively stable over time, it is also subject to change across the entire lifespan. On a macro-analytical level, empirical research has identified patterns of normative and differential development that are affected by biological and environmental factors, specific life events, and social role investments. On a…

  16. Control of Airborne Infectious Diseases in Ventilated Spaces

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    2009-01-01

    We protect ourselves from airborne cross-infection in the indoor environment by supplying fresh air to a room by natural or mechanical ventilation. The air is distributed in the room according to different principles: mixing ventilation, displacement ventilation, etc. A large amount of air...... to have high ventilation effectiveness. Furthermore, personalized ventilation may reduce the risk of cross-infection, and in some cases, it can also reduce the source of infection. Personalized ventilation can especially be used in hospital wards, aircraft cabins and, in general, where people are in fixed...

  17. [AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders].

    Science.gov (United States)

    Schlüter-Müller, Susanne

    2017-07-01

    AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders Personality disorders are patterns of maladaptive personality traits that have an impact on the individual throughout the life span. Borderline Personality Disorder (BPD) is a very severe, but treatable mental disorder. Identity disturbance is seen as the central construct for detecting severe personality pathology - and, most notably, borderline personality disorder - in adults and adolescents. Crises in the development of identity usually resolve into a normal and consolidated identity with flexible and adaptive functioning whereas identity diffusion is viewed as a lack of integration of the concept of the self and significant others. It is seen as the basis for subsequent personality pathology, including that of borderline personality disorder. Although BPD has its onset in adolescence and emerging adulthood the diagnosis is often delayed. In most cases, specific treatment is only offered late in the course of the disorder and to relatively few individuals. Adolescent Identity Treatment (AIT) is a treatment model that focuses on identity pathology as the core characteristic of personality disorders. This model integrates specific techniques for the treatment of adolescent personality pathology on the background of object-relation theories and modified elements of Transference-Focused Psychotherapy. Moreover, psychoeducation, a behavior-oriented homeplan and intensive family work is part of AIT.

  18. Integrating normal and abnormal personality structure: a proposal for DSM-V.

    Science.gov (United States)

    Widiger, Thomas A

    2011-06-01

    The personality disorders section of the American Psychiatric Association's fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) is currently being developed. The purpose of the current paper is to encourage the authors of DSM-V to integrate normal and abnormal personality structure within a common, integrative model, and to suggest that the optimal choice for such an integration would be the five-factor model (FFM) of general personality structure. A proposal for the classification of personality disorder from the perspective of the FFM is provided. Discussed as well are implications and issues associated with an FFM of personality disorder, including validity, coverage, feasibility, clinical utility, and treatment implications.

  19. Traits and states: Integrating personality and affect into a model of criminal decision making

    NARCIS (Netherlands)

    van Gelder, J.L.; de Vries, R.E.

    2012-01-01

    We propose and test a model of criminal decision making that integrates the individual differences perspective with research and theorizing on proximal factors. The individual differences perspective is operationalized using the recent HEXACO personality structure. This structure incorporates the

  20. Positive politics: playing corporate games with personal integrity.

    Science.gov (United States)

    Ogborn, S E

    1992-12-01

    The desire for power is personal. Competence and political intelligence are the prerequisites for handling power in a healthy manner. Politics is not a nasty word or a set of behaviors that inevitably turns you into a shady character of whom your mother would be ashamed. You need never divorce your own morality from the situation. The choice to improve your political functioning is yours. You always retain the right to play, and you retain the right to decide when to play. But you are a better manager, a better professional, and a more educated person if you can identify what others are doing and how their behavior will impact you. It is not just for success, it is for survival--success and survival on your own terms.

  1. [Schema therapy: an integrative approach for personality disorders].

    Science.gov (United States)

    Roediger, Eckhard; Dieckmann, Eva

    2012-01-01

    Schema Therapy (ST) is a comprehensive approach deriving from cognitive behavioral therapy (CBT) for the treatment of chronic personality problems. ST extends CBT in 3 major issues: 1. The Schema-Mode-Model. 2. The therapeutic relationship. 3. The intensive use of experiential techniques. Schemas are persistent, rigid, and dysfunctional patterns preventing the patient from further personal emotive-interpersonal development. The central focus of the therapeutic process is the relationship between the therapist and the patient. Supported by the therapeutic relationship the patient gets in touch with painful childhood experiences. In ST, the core schemas are identified, put into a biographical context, and weakened by using several specific therapeutic techniques including experiential methods and strategies taken from Gestalt therapy that enrich traditional CBT techniques. © Georg Thieme Verlag KG Stuttgart · New York.

  2. A New Approach to Personalization: Integrating E-Learning and M-Learning

    Science.gov (United States)

    Nedungadi, Prema; Raman, Raghu

    2012-01-01

    Most personalized learning systems are designed for either personal computers (e-learning) or mobile devices (m-learning). Our research has resulted in a cloud-based adaptive learning system that incorporates mobile devices into a classroom setting. This system is fully integrated into the formative assessment process and, most importantly,…

  3. Integrating Culture and Second Language Teaching through Yoruba Personal Names

    Science.gov (United States)

    Akinyemi, Akintunde

    2005-01-01

    Using Yoruba as a case study, this article demonstrates the fact that the languages of Africa and the cultures of its peoples are inseparable. Therefore, the study advocates that appropriate aspects of these cultures should form an integral part of African language teaching. This article discusses specifically how language teachers can transmit…

  4. Examining Acceptance of an Integrated Personal Health Record (PHR)

    Science.gov (United States)

    Morton, Alicia A.

    2011-01-01

    Objective: The purpose of this project was to examine the practice question, "What are the factors influencing acceptance of integrated PHRs for self-care management among the Howard University Hospital (HUH) Diabetes Treatment Clinic (DTC) patients?" These factors include a) demographic characteristics, b) computer…

  5. CLEAN-AIR heat pump. Reduced energy consumption for ventilation in buildings by integrating air cleaning and heat pump. Final Report; CLEAN-AIR heat pump - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Fang, L.; Olesen, Bjarne W.; Molinaro, G.; Simmonsen, P.; Skocajic, S. [Danmarks Tekniske Univ. Institut for Byggeri og Anlaeg, Lyngby (Denmark); Hummelshoej, R.M.; Carlassara, L. [COWI A/S, Lyngby, (Denmark); Groenbaek, H.; Hansen, Ole R. [Exhausto A/S, Langeskov (Denmark)

    2011-07-01

    This report summarizes task 1 of the Clean Air Heat Pump project - modelling and simulation on energy savings when using the clean air heat pump for ventilation, air cleaning and energy recovery. The total energy consumption of the proposed ventilation systems using clean air heat pump technology was calculated by a theoretical model and compared with the reference ventilation systems (conventional ventilation systems). The energy compared between the two systems includes energy used for heating, cooling and fan. The simulation and energy saving calculation was made for the application of the clean air heat pump in three typical climate conditions, i.e. mild-cold, mild-hot and hot and wet climates. Real climate data recorded from three cities in 2002 was used for the calculation. The three cities were Copenhagen (Denmark), Milan (Italy) and Colombo (Sir Lanka) which represent the above three typical climate zones. For the Danish climate (the mild cold climate), the calculations show that the ventilation system using clean air heat pump technology can save up to 42% of energy cost in winter compared to the conventional ventilation system. The energy saving in summer can be as high as 66% for the ventilation system with humidity control and 9% for the ventilation system without the requirement of humidity control. Since the Danish summer climate is very mild, over 80% of the yearly energy consumption for ventilation is used during winter season. It is, therefore, estimated that more than 35% annual energy saving for ventilation is expected in Denmark using the clean air heat pump ventilation technology. For the mild hot climate, e.g. the Italian climate, the calculations show that up to 63% of the energy saving can be achieved in summer season. For the winter mode, 17% reduction of the energy cost can be expected for the domestic use. For industrial use, the energy cost of the clean air heat pump may not be favourable due to the industrial price of gas in Italy is

  6. Integrating personal medicine into service delivery: empowering people in recovery.

    Science.gov (United States)

    MacDonald-Wilson, Kim L; Deegan, Patricia E; Hutchison, Shari L; Parrotta, Nancy; Schuster, James M

    2013-12-01

    Illness management and recovery strategies are considered evidence-based practices. The article describes how a web-based application, CommonGround, has been used to support implementation of such strategies in outpatient mental health services and assess its impact. The specific focus of this article is Personal Medicine, self-management strategies that are a salient component of the CommonGround intervention. With support from counties and a not-for-profit managed care organization, CommonGround has been introduced in 10 medication clinics, one Assertive Community Treatment (ACT) team, and one peer support center across Pennsylvania. Methods include analysis of data from the application's database and evaluation of health functioning, symptoms, and progress toward recovery. Health functioning improved over time and use of self-management strategies was associated with fewer concerns about medication side effects, fewer concerns about the impact of mental health medicine on physical health, more reports that mental health medicines were helping, and greater progress in individuals' recovery. Using Personal Medicine empowers individuals to work with their prescribers to find a "right balance" between what they do to be well and what they take to be well. This program helps individuals and their service team focus on individual strengths and resilient self-care strategies. More research is needed to assess factors that may predict changes in outcomes and how a web-based tool focused on self-management strategies may moderate those factors. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  7. 16 CFR 312.8 - Confidentiality, security, and integrity of personal information collected from children.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Confidentiality, security, and integrity of... COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS CHILDREN'S ONLINE PRIVACY PROTECTION RULE § 312.8 Confidentiality, security, and integrity of personal information collected from children. The operator must...

  8. Neither Right nor Wrong: How a Teacher Integrates Her Personal and Professional Life with Policy

    Science.gov (United States)

    Bunten, Bridget A.

    2014-01-01

    This article focuses on the importance of recognizing and appreciating the ways that a teacher integrates her personal and professional life with an English-only policy. Much can be learned from the ways in which she negotiates social forces and integrates them into her individual reality while making sense of the restrictive language policy.…

  9. The relation of ego integrity and despair to personality traits and mental health

    NARCIS (Netherlands)

    Westerhof, Gerben J.; Bohlmeijer, Ernst T.; McAdams, Dan P.

    Objectives: Existing studies in the Eriksonian tradition found that ego integrity and despair are important indicators of life-span development. The present study relates ego integrity and despair to contemporary theories of personality and mental health. Method: A cross-sectional study of Dutch

  10. The university professor: integration between the personal and professional dimension

    Directory of Open Access Journals (Sweden)

    José Javier BERMÚDEZ-APONTE

    2017-12-01

    Full Text Available In the first part of this article, the authors explain how the teaching role is affected by certain social and cultural changes, like the knowledge society emergence, the universities orientation towards marketing, the constant demand and pressure exerted on teachers to publish, the loss of the ethical sense in the academic activity and the disparity of tasks that are being assigned to the university professors. In view of the above, a comprehensive model, compound by two concepts –personal and professional– of a university professor is proposed; in fact, this model incorporates and summarises different contributions regarding this theme. Finally, this article aims to defend the need to understand the teaching role as a vocation, in the broadest sense of the word, a vocation carries the inclination to pursue an aim: the education of those students that teachers have in charge.

  11. Values and principles of person-centered integrated care: a systematic literature review (SIG meeting)

    OpenAIRE

    Zonneveld, Nick; Miller, Robin; Minkman, Mirella

    2017-01-01

    Introduction: In recent years many knowledge about integrated health services has been developed. So far research has focused on operational themes and interventions on the one side, which help decision makers in practice. On the other hand, a number of studies about generic elements of person-centered and integrated care have been published, resulting in valuable conceptual models and frameworks [1-9]. A third area of research is how to measure integrated care.However, if we want to further ...

  12. EU Integration and Harmonisation of Personal Income Taxation

    Directory of Open Access Journals (Sweden)

    Tomasz Wołowiec

    2011-07-01

    Full Text Available In the process of furthering EU integration little attention was given to the role of income taxes. Multiple income tax systems exist across the Union and their differentiation negatively impacts the European labour market, investments and savings, inhibiting economic growth. Individual nations have little motivation to harmonise as they can engage in tax rate competition and income taxes are interwoven with social security systems that make any attempts at reform extremely complex and politically unpopular. Much of current harmonisation is “silent”, paralegal, and occurs in response to market forces rather than following a formal plan and through intergovernmental cooperation.

  13. Person and consumption profiles. Building integrated energy supply; Person- og forbrugsprofiler. Bygningsintegreret energiforsyning

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Rasmus L.; Noergaard, J.; Daniels, O.; Justesen, R.O.

    2011-08-15

    In the future, buildings will not only act as consumers of energy but as producers as well. For these ''prosumers'', energy production by use of solar panels, photovoltaics and heat pumps etc will be essential. The objective of this project was to find the most optimal combinations of building insulation and use of renewable energy sources in existing buildings in terms of economics and climate impacts. Five houses were analyzed based on different personal load, consumption profiles, solar orientation and proposed building envelope improvements and use of combinations of renewable energy systems. The present report describes how person and consumption profiles used in this project are developed, and which data that form the basis for these profiles. The increasing requirements for energy in the building sector mean that the primary energy consumption ends close to or below zero within the next years. Therefore, the consumption in buildings becomes a relatively larger and larger part of the total energy demand in dwellings. It is important to investigate whether there are seasonal distributions of power and water consumption, because it might give a more exact result and describe the reality better than by using yearly values. First, the personal load determined, and then humidity and consumption of both power and hot water is defined. Second, the hourly profiles are developed based on analyses of seasonal distributions. These profiles also include cold domestic water to see whether there is a correlation between this and hot domestic water. (ln)

  14. Development of a Personal Integrated Environmental Monitoring System

    Directory of Open Access Journals (Sweden)

    Man Sing Wong

    2014-11-01

    Full Text Available Environmental pollution in the urban areas of Hong Kong has become a serious public issue but most urban inhabitants have no means of judging their own living environment in terms of dangerous threshold and overall livability. Currently there exist many low-cost sensors such as ultra-violet, temperature and air quality sensors that provide reasonably accurate data quality. In this paper, the development and evaluation of Integrated Environmental Monitoring System (IEMS are illustrated. This system consists of three components: (i position determination and sensor data collection for real-time geospatial-based environmental monitoring; (ii on-site data communication and visualization with the aid of an Android-based application; and (iii data analysis on a web server. This system has shown to be working well during field tests in a bus journey and a construction site. It provides an effective service platform for collecting environmental data in near real-time, and raises the public awareness of environmental quality in micro-environments.

  15. Appointment, qualifications and responsibilities of ventilation officers

    International Nuclear Information System (INIS)

    1981-01-01

    The Code provides for the appointment of a ventilation officer when required by the appropriate authority. This guideline offers comment on the appointment, qualifications, training and responsibilities of that person

  16. Summary of human responses to ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli A.; Fisk, William J.

    2004-06-01

    The effects of ventilation on indoor air quality and health is a complex issue. It is known that ventilation is necessary to remove indoor generated pollutants from indoor air or dilute their concentration to acceptable levels. But, as the limit values of all pollutants are not known, the exact determination of required ventilation rates based on pollutant concentrations and associated risks is seldom possible. The selection of ventilation rates has to be based also on epidemiological research (e.g. Seppanen et al., 1999), laboratory and field experiments (e.g. CEN 1996, Wargocki et al., 2002a) and experience (e.g. ECA 2003). Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated as summarized by Seppdnen (2003). Ventilation may bring indoors harmful substances that deteriorate the indoor environment. Ventilation also affects air and moisture flow through the building envelope and may lead to moisture problems that deteriorate the structures of the building. Ventilation changes the pressure differences over the structures of building and may cause or prevent the infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. Ventilation can be implemented with various methods which may also affect health (e.g. Seppdnen and Fisk, 2002, Wargocki et al., 2002a). In non residential buildings and hot climates, ventilation is often integrated with air-conditioning which makes the operation of ventilation system more complex. As ventilation is used for many purposes its health effects are also various and complex. This paper summarizes the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus of the paper is on office-type working environment and residential buildings. In the industrial premises the problems of air quality are usually

  17. Ventilator-driven xenon ventilation studies

    International Nuclear Information System (INIS)

    Chilcoat, R.T.; Thomas, F.D.; Gerson, J.I.

    1984-01-01

    A modification of a common commercial Xe-133 ventilation device is described for mechanically assisted ventilation imaging. The patient's standard ventilator serves as the power source controlling the ventilatory rate and volume during the xenon study, but the gases in the two systems are not intermixed. This avoids contamination of the ventilator with radioactive xenon. Supplemental oxygen and positive end-expiratory pressure (PEEP) are provided if needed. The system can be converted quickly for conventional studies with spontaneous respiration

  18. Short-term airing by natural ventilation

    DEFF Research Database (Denmark)

    Perino, Marco; Heiselberg, Per

    2009-01-01

    The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates traditio......The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates...... traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates...... that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ....

  19. Sojourners' second language learning and integration. The moderating effect of multicultural personality traits

    NARCIS (Netherlands)

    van Niejenhuis, Coby; Otten, Sabine; Flache, Andreas

    This study examines the role of trainable intercultural personality traits in the widely assumed link between immigrants' second language (L2) learning and their cultural integration in the host country. The research was based on data of temporary immigrants (sojourners), being international

  20. Integrating the Differentiated: A Review of the Personal Construct Approach to Cognitive Complexity

    OpenAIRE

    Kovářová, M. (Marie); Filip, M. (Miroslav)

    2015-01-01

    This article reviews personal construct psychology (PCP) research on cognitive complexity. It examines conceptual foundations, measures of cognitive complexity, and a large body of empirical findings. It identifies several ambiguities in the conceptualization of the two components of cognitive complexity: differentiation and integration. These ambiguities lead to inconsistent interpretations of indexes proposed for their measurement and consequently to an inconsistent interpretation of em...

  1. Integrating Personal Development and Career Planning: The Outcomes for First Year Undergraduate Learning

    Science.gov (United States)

    Monks, Kathy; Conway, Edel; Dhuigneain, Muireann Ni

    2006-01-01

    This article describes the way in which colleagues from the Business faculty, the Careers Service and the Library at Dublin City University collaborated to design and deliver an integrated approach to personal development planning (PDP) with the aim of motivating first year undergraduate students to take greater responsibility for their own…

  2. Research on Multi - Person Parallel Modeling Method Based on Integrated Model Persistent Storage

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper mainly studies the multi-person parallel modeling method based on the integrated model persistence storage. The integrated model refers to a set of MDDT modeling graphics system, which can carry out multi-angle, multi-level and multi-stage description of aerospace general embedded software. Persistent storage refers to converting the data model in memory into a storage model and converting the storage model into a data model in memory, where the data model refers to the object model and the storage model is a binary stream. And multi-person parallel modeling refers to the need for multi-person collaboration, the role of separation, and even real-time remote synchronization modeling.

  3. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    with conventional ventilation systems (mixing or displacement ventilation), diffuse ceiling ventilation can significantly reduce or even eliminate draught risk in the occupied zone. Moreover, this ventilation system presents a promising opportunity for energy saving, because of the low pressure loss, extended free...

  4. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...

  5. Variable mechanical ventilation.

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini, Luiz Alberto; Friedman, Gilberto

    2017-01-01

    To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation.

  6. VENTILATION NEEDS DURING CONSTRUCTION

    International Nuclear Information System (INIS)

    C.R. Gorrell

    1998-01-01

    The purpose of this analysis is to determine ventilation needs during construction and development of the subsurface repository and develop systems to satisfy those needs. For this analysis, construction is defined as pre-emplacement excavation and development is excavation that takes place simultaneously with emplacement. The three options presented in the ''Overall Development and Emplacement Ventilation Systems'' analysis (Reference 5.5) for development ventilation will be applied to construction ventilation in this analysis as well as adding new and updated ventilation factors to each option for both construction and development. The objective of this analysis is to develop a preferred ventilation system to support License Application Design. The scope of this analysis includes: (1) Description of ventilation conditions; (2) Ventilation factors (fire hazards, dust control, construction logistics, and monitoring and control systems); (3) Local ventilation alternatives; (4) Global ventilation options; and (5) Evaluation of options

  7. [Effectiveness of an integrated treatment for severe personality disorders. A 36-month pragmatic follow-up].

    Science.gov (United States)

    Lana, Fernando; Sánchez-Gil, Carmen; Ferrer, Laia; López-Patón, Nuria; Litvan, Lia; Marcos, Susana; Sierra, Ana C; Soldevilla, Joan M; Feixas, Guillem; Pérez, Víctor

    2015-01-01

    Over the past 25 years, several studies have shown the efficacy of a number of psychological interventions for severe personality disorders. However, the generalizability of these positive results from long traditional research settings to more ordinary ones has been questioned, requiring a need for replication in pragmatic studies. This pragmatic study compares hospitalizations and Emergency Room visits before and during a 6-month therapeutic program for severe personality disorders, and at 36 months after starting it. The therapeutic program, which integrates several specific interventions within a coherent framework, was carried out in an ordinary clinical setting. Fifty-one patients, evaluated according DSM-IV criteria by using the Spanish version of the Structured Clinical Interview for Personality Disorders (SCID-II), were included. The clinical characteristics showed a group of severely disturbed patients, of which 78.4% met criteria for borderline personality disorder. The percentage of patients hospitalized and visiting the Emergency Room, as well as the number of days of hospitalization and Emergency Room visits was significantly reduced during the treatment, and this improvement was maintained throughout. An integrated treatment for severe personality disorders could be effective in preventing reliance on readmissions, or prolonged hospital stays, when it is implemented by clinicians in ordinary clinical settings. Copyright © 2014 SEP y SEPB. Published by Elsevier España. All rights reserved.

  8. Integration of Multisensor Hybrid Reasoners to Support Personal Autonomy in the Smart Home

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Valero

    2014-09-01

    Full Text Available The deployment of the Ambient Intelligence (AmI paradigm requires designing and integrating user-centered smart environments to assist people in their daily life activities. This research paper details an integration and validation of multiple heterogeneous sensors with hybrid reasoners that support decision making in order to monitor personal and environmental data at a smart home in a private way. The results innovate on knowledge-based platforms, distributed sensors, connected objects, accessibility and authentication methods to promote independent living for elderly people. TALISMAN+, the AmI framework deployed, integrates four subsystems in the smart home: (i a mobile biomedical telemonitoring platform to provide elderly patients with continuous disease management; (ii an integration middleware that allows context capture from heterogeneous sensors to program environment´s reaction; (iii a vision system for intelligent monitoring of daily activities in the home; and (iv an ontologies-based integrated reasoning platform to trigger local actions and manage private information in the smart home. The framework was integrated in two real running environments, the UPM Accessible Digital Home and MetalTIC house, and successfully validated by five experts in home care, elderly people and personal autonomy.

  9. Integration of multisensor hybrid reasoners to support personal autonomy in the smart home.

    Science.gov (United States)

    Valero, Miguel Ángel; Bravo, José; Chamizo, Juan Manuel García; López-de-Ipiña, Diego

    2014-09-17

    The deployment of the Ambient Intelligence (AmI) paradigm requires designing and integrating user-centered smart environments to assist people in their daily life activities. This research paper details an integration and validation of multiple heterogeneous sensors with hybrid reasoners that support decision making in order to monitor personal and environmental data at a smart home in a private way. The results innovate on knowledge-based platforms, distributed sensors, connected objects, accessibility and authentication methods to promote independent living for elderly people. TALISMAN+, the AmI framework deployed, integrates four subsystems in the smart home: (i) a mobile biomedical telemonitoring platform to provide elderly patients with continuous disease management; (ii) an integration middleware that allows context capture from heterogeneous sensors to program environment's reaction; (iii) a vision system for intelligent monitoring of daily activities in the home; and (iv) an ontologies-based integrated reasoning platform to trigger local actions and manage private information in the smart home. The framework was integrated in two real running environments, the UPM Accessible Digital Home and MetalTIC house, and successfully validated by five experts in home care, elderly people and personal autonomy.

  10. Integration of Multisensor Hybrid Reasoners to Support Personal Autonomy in the Smart Home

    Science.gov (United States)

    Valero, Miguel Ángel; Bravo, José; Chamizo, Juan Manuel García; López-de-Ipiña, Diego

    2014-01-01

    The deployment of the Ambient Intelligence (AmI) paradigm requires designing and integrating user-centered smart environments to assist people in their daily life activities. This research paper details an integration and validation of multiple heterogeneous sensors with hybrid reasoners that support decision making in order to monitor personal and environmental data at a smart home in a private way. The results innovate on knowledge-based platforms, distributed sensors, connected objects, accessibility and authentication methods to promote independent living for elderly people. TALISMAN+, the AmI framework deployed, integrates four subsystems in the smart home: (i) a mobile biomedical telemonitoring platform to provide elderly patients with continuous disease management; (ii) an integration middleware that allows context capture from heterogeneous sensors to program environment's reaction; (iii) a vision system for intelligent monitoring of daily activities in the home; and (iv) an ontologies-based integrated reasoning platform to trigger local actions and manage private information in the smart home. The framework was integrated in two real running environments, the UPM Accessible Digital Home and MetalTIC house, and successfully validated by five experts in home care, elderly people and personal autonomy. PMID:25232910

  11. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  12. Digital Technologies Supporting Person-Centered Integrated Care – A Perspective

    Science.gov (United States)

    2017-01-01

    Shared electronic health and social care records in some service systems are already showing some of the benefits of digital technology and digital data for integrating health and social care. These records are one example of the beginning “digitalisation” of services that gives a glimpse of the potential of digital technology and systems for building coordinated and individualized integrated care. Yet the promise has been greater than the benefits, and progress has been slow compared to other industries. This paper describes for non-technical readers how information technology was used to support integrated care schemes in six EU services, and suggests practical ways forward to use the new opportunities to build person-centered integrated care. PMID:29588629

  13. Digital Technologies Supporting Person-Centered Integrated Care – A Perspective

    Directory of Open Access Journals (Sweden)

    John Øvretveit

    2017-09-01

    Full Text Available Shared electronic health and social care records in some service systems are already showing some of the benefits of digital technology and digital data for integrating health and social care. These records are one example of the beginning “digitalisation” of services that gives a glimpse of the potential of digital technology and systems for building coordinated and individualized integrated care. Yet the promise has been greater than the benefits, and progress has been slow compared to other industries. This paper describes for non-technical readers how information technology was used to support integrated care schemes in six EU services, and suggests practical ways forward to use the new opportunities to build person-centered integrated care.

  14. What it takes to get proactive: An integrative multilevel model of the antecedents of personal initiative.

    Science.gov (United States)

    Hong, Ying; Liao, Hui; Raub, Steffen; Han, Joo Hun

    2016-05-01

    Building upon and extending Parker, Bindl, and Strauss's (2010) theory of proactive motivation, we develop an integrated, multilevel model to examine how contextual factors shape employees' proactive motivational states and, through these proactive motivational states, influence their personal initiative behavior. Using data from a sample of hotels collected from 3 sources and over 2 time periods, we show that establishment-level initiative-enhancing human resource management (HRM) systems were positively related to departmental initiative climate, which was positively related to employee personal initiative through employee role-breadth self-efficacy. Further, department-level empowering leadership was positively related to initiative climate only when initiative-enhancing HRM systems were low. These findings offer interesting implications for research on personal initiative and for the management of employee proactivity in organizations. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Integrating Personalized and Community Services for Mobile Travel Planning and Management

    Science.gov (United States)

    Yu, Chien-Chih

    Personalized and community services have been noted as keys to enhance and facilitate e-tourism as well as mobile applications. This paper aims at proposing an integrated service framework for combining personalized and community functions to support mobile travel planning and management. Major mobile tourism related planning and decision support functions specified include personalized profile management, information search and notification, evaluation and recommendation, do-it-yourself planning and design, community and collaboration management, auction and negotiation, transaction and payment, as well as trip tracking and quality control. A system implementation process with an example prototype is also presented for illustrating the feasibility and effectiveness of the proposed system framework, process model, and development methodology.

  16. An integral approach to town planning: lessons from personal construct theory, part 1

    OpenAIRE

    A Jackson

    1986-01-01

    Personal construct theory is introduced as an all-embracing philosophy which provides a consistent framework for integrating different notions about the planning process. The implication is that 'man-the-planner' does not necessarily have constructs which are better, more accurate, or more predictive than his subject, 'man-the-planned'. Policies can be seen as theories, in which case they should be clearly expressed as such. The theory and its methodology have been used in an empirical invest...

  17. Integrated Personal Health and Care Services deployment: Experiences in eight European countries

    DEFF Research Database (Denmark)

    Villalba, Elena; Casas, Isabel; Abadie, Fabienne

    2013-01-01

    conditions for mainstreaming these services into care provision. Methods: We conducted a qualitative analysis of 27 Telehealth, Telecare and Integrated Personal Health System projects, implemented across 20 regions in eight European countries. The analysis was based on Suter’s ten key principles...... mechanisms, interoperable information systems, policy commitment, engaged professionals, national investments and funding programmes, and incentives and financing. Conclusion: In those cases which provided evidence of success beyond the pilot stage, we observed a promising trend: awareness and introduction...

  18. Integrated Personal Health Records: Transformative Tools for Consumer-Centric Care

    Directory of Open Access Journals (Sweden)

    Raymond Brian

    2008-10-01

    Full Text Available Abstract Background Integrated personal health records (PHRs offer significant potential to stimulate transformational changes in health care delivery and self-care by patients. In 2006, an invitational roundtable sponsored by Kaiser Permanente Institute, the American Medical Informatics Association, and the Agency for Healthcare Research and Quality was held to identify the transformative potential of PHRs, as well as barriers to realizing this potential and a framework for action to move them closer to the health care mainstream. This paper highlights and builds on the insights shared during the roundtable. Discussion While there is a spectrum of dominant PHR models, (standalone, tethered, integrated, the authors state that only the integrated model has true transformative potential to strengthen consumers' ability to manage their own health care. Integrated PHRs improve the quality, completeness, depth, and accessibility of health information provided by patients; enable facile communication between patients and providers; provide access to health knowledge for patients; ensure portability of medical records and other personal health information; and incorporate auto-population of content. Numerous factors impede widespread adoption of integrated PHRs: obstacles in the health care system/culture; issues of consumer confidence and trust; lack of technical standards for interoperability; lack of HIT infrastructure; the digital divide; uncertain value realization/ROI; and uncertain market demand. Recent efforts have led to progress on standards for integrated PHRs, and government agencies and private companies are offering different models to consumers, but substantial obstacles remain to be addressed. Immediate steps to advance integrated PHRs should include sharing existing knowledge and expanding knowledge about them, building on existing efforts, and continuing dialogue among public and private sector stakeholders. Summary Integrated PHRs

  19. Questionnaire-based person trip visualization and its integration to quantitative measurements in Myanmar

    Science.gov (United States)

    Kimijiama, S.; Nagai, M.

    2016-06-01

    With telecommunication development in Myanmar, person trip survey is supposed to shift from conversational questionnaire to GPS survey. Integration of both historical questionnaire data to GPS survey and visualizing them are very important to evaluate chronological trip changes with socio-economic and environmental events. The objectives of this paper are to: (a) visualize questionnaire-based person trip data, (b) compare the errors between questionnaire and GPS data sets with respect to sex and age and (c) assess the trip behaviour in time-series. Totally, 345 individual respondents were selected through random stratification to assess person trip using a questionnaire and GPS survey for each. Conversion of trip information such as a destination from the questionnaires was conducted by using GIS. The results show that errors between the two data sets in the number of trips, total trip distance and total trip duration are 25.5%, 33.2% and 37.2%, respectively. The smaller errors are found among working-age females mainly employed with the project-related activities generated by foreign investment. The trip distant was yearly increased. The study concluded that visualization of questionnaire-based person trip data and integrating them to current quantitative measurements are very useful to explore historical trip changes and understand impacts from socio-economic events.

  20. [Integrity].

    Science.gov (United States)

    Gómez Rodríguez, Rafael Ángel

    2014-01-01

    To say that someone possesses integrity is to claim that that person is almost predictable about responses to specific situations, that he or she can prudentially judge and to act correctly. There is a closed interrelationship between integrity and autonomy, and the autonomy rests on the deeper moral claim of all humans to integrity of the person. Integrity has two senses of significance for medical ethic: one sense refers to the integrity of the person in the bodily, psychosocial and intellectual elements; and in the second sense, the integrity is the virtue. Another facet of integrity of the person is la integrity of values we cherish and espouse. The physician must be a person of integrity if the integrity of the patient is to be safeguarded. The autonomy has reduced the violations in the past, but the character and virtues of the physician are the ultimate safeguard of autonomy of patient. A field very important in medicine is the scientific research. It is the character of the investigator that determines the moral quality of research. The problem arises when legitimate self-interests are replaced by selfish, particularly when human subjects are involved. The final safeguard of moral quality of research is the character and conscience of the investigator. Teaching must be relevant in the scientific field, but the most effective way to teach virtue ethics is through the example of the a respected scientist.

  1. Patient-Ventilator Dyssynchrony

    Directory of Open Access Journals (Sweden)

    Elvira-Markela Antonogiannaki

    2017-11-01

    Full Text Available In mechanically ventilated patients, assisted mechanical ventilation (MV is employed early, following the acute phase of critical illness, in order to eliminate the detrimental effects of controlled MV, most notably the development of ventilator-induced diaphragmatic dysfunction. Nevertheless, the benefits of assisted MV are often counteracted by the development of patient-ventilator dyssynchrony. Patient-ventilator dyssynchrony occurs when either the initiation and/or termination of mechanical breath is not in time agreement with the initiation and termination of neural inspiration, respectively, or if the magnitude of mechanical assist does not respond to the patient’s respiratory demand. As patient-ventilator dyssynchrony has been associated with several adverse effects and can adversely influence patient outcome, every effort should be made to recognize and correct this occurrence at bedside. To detect patient-ventilator dyssynchronies, the physician should assess patient comfort and carefully inspect the pressure- and flow-time waveforms, available on the ventilator screen of all modern ventilators. Modern ventilators offer several modifiable settings to improve patient-ventilator interaction. New proportional modes of ventilation are also very helpful in improving patient-ventilator interaction.

  2. [DGPPN compass of participation for vocational integration of persons with mental illnesses].

    Science.gov (United States)

    Stengler, K; Rauschenbach, J; Riedel-Heller, S G; Becker, T; Steinhart, I; Gerlinger, G; Hauth, I

    2016-11-01

    Working and living for persons with mental illnesses are a major concern of rehabilitative psychiatry. In Germany the definition of rehabilitation for persons with mental illnesses is closely linked to different sectors of social welfare and to the strongly organized supply chain of prevention, acute treatment, rehabilitation and care. In successfully supporting people with mental health problems in terms of vocational integration, professionals face various obstacles. Besides finding the correct content, structural and organizational difficulties can also arise. The welfare system with its specific institutions and settings is complicated which often leads to delays in the onset of rehabilitation. Some essential reasons are insufficient knowledge about established options of rehabilitative treatment and about responsibilities related to participation in specialized training and further education for professional caregivers. Also information and (positive) experiences from pilot projects working in an inclusive, cross-sectional way and across different settings are practically unavailable in Germany. The presented compass of participation from the German Association for Psychiatry, Psychotherapy and Psychosomatics (DGPPN) for vocational integration of persons with mental illnesses starts at this point: it provides guidelines for psychiatric and psychotherapeutic practitioners, general practitioners as well as for physicians working in residential or day care institutions with a psychiatric and psychotherapeutic background. Both the paper and planned online versions should help professionals to help people, particularly those with severe mental illnesses to navigate the system of services for vocational integration in Germany.

  3. Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Pantelic, Jovan

    2015-01-01

    The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body...... shape, size, and surface temperatures correspond to those of an average person is used to simulate the CBL. The findings of the study reveal that for accurate predictions of personal exposure, the CBL needs to be considered, as it can transport the pollution around the human body. The best way...... to control and reduce personal exposure when the pollution originates at the feet is to employ transverse flow from in front and from the side, relative to the exposed occupant. The flow from the above opposing the CBL create the most unfavorable velocity field that can increase personal exposure by 85...

  4. Mechanical ventilator - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007240.htm Mechanical ventilator - infants To use the sharing features on this page, please enable JavaScript. A mechanical ventilator is a machine that assists with breathing. ...

  5. Integrating the context-appropriate balanced attention model and reinforcement sensitivity theory: Towards a domain-general personality process model.

    Science.gov (United States)

    Collins, Michael D; Jackson, Chris J; Walker, Benjamin R; O'Connor, Peter J; Gardiner, Elliroma

    2017-01-01

    Over the last 40 years or more the personality literature has been dominated by trait models based on the Big Five (B5). Trait-based models describe personality at the between-person level but cannot explain the within-person mental mechanisms responsible for personality. Nor can they adequately account for variations in emotion and behavior experienced by individuals across different situations and over time. An alternative, yet understated, approach to personality architecture can be found in neurobiological theories of personality, most notably reinforcement sensitivity theory (RST). In contrast to static trait-based personality models like the B5, RST provides a more plausible basis for a personality process model, namely, one that explains how emotions and behavior arise from the dynamic interaction between contextual factors and within-person mental mechanisms. In this article, the authors review the evolution of a neurobiologically based personality process model based on RST, the response modulation model and the context-appropriate balanced attention model. They argue that by integrating this complex literature, and by incorporating evidence from personality neuroscience, one can meaningfully explain personality at both the within- and between-person levels. This approach achieves a domain-general architecture based on RST and self-regulation that can be used to align within-person mental mechanisms, neurobiological systems and between-person measurement models. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. Owning Up to Negative Ingroup Traits: How Personal Autonomy Promotes the Integration of Group Identity.

    Science.gov (United States)

    Legault, Lisa; Weinstein, Netta; Mitchell, Jahlil; Inzlicht, Michael; Pyke, Kristen; Upal, Afzal

    2017-10-01

    Our experiences, attributes, and behaviors are diverse, inconsistent, and often negative. Consequently, our capacity to assimilate divergent experiences-particularly negative aspects-is important to the development of a unified self. Whereas this process of integration has received attention at the level of personal identity, it has not been assessed at the level of group identity. We examined the mechanisms involved in integrating positive and negative ingroup identities, as well as related outcomes. In three experiments, participants (N = 332) high and low in autonomy identified either positive or negative aspects of their ingroup and then indicated the extent to which they integrated the attribute. Those high in personal autonomy integrated both positive and negative identities, whereas those low in autonomy acknowledged only positive identities. Study 2 showed that, regardless of identity valence, those high in autonomy felt satisfied and close with their group. Conversely, those low in autonomy felt less close and more dissatisfied with their group after reflecting on negative identities. Finally, reflecting on a negative identity reduced prejudice, but only for those high in autonomy. Owning up to negative group traits is facilitated by autonomy and demonstrates benefits for ingroup and intergroup processes. © 2016 Wiley Periodicals, Inc.

  7. Participation and integration from the perspective of persons with spinal cord injury from five European countries.

    Science.gov (United States)

    Ruoranen, Kaisa; Post, Marcel W M; Juvalta, Sibylle; Reinhardt, Jan D

    2015-03-01

    To examine the subjective understanding of participation and integration of persons with spinal cord injuries from 5 European countries and to compare these findings with the International Classification of Functioning, Disability and Health (ICF)'s conceptualization of participation. Semi-structured interviews with 54 persons with acquired spinal cord injuries and 3 with spina bifida from 5 countries were examined using qualitative content analysis. Integration was most often associated with social acceptance and, furthermore, with ordinary performance, equality and freedom of choice. Participation was most often described as ordinary performance, with less emphasis on social acceptance and equality. However, participation and integration overlapped in people's narratives and were difficult to separate. The perception of participation and integration was largely similar across countries. In contrast to others, however, Finnish interviewees were more likely to associate participation with contributing to society. A variety of life domains was identified, of which recreation and leisure, work life, sports and going out were the most prevalent. While participation domains are well covered by the ICF, as is the notion of ordinary performance, interviewees also referred to a rights (e.g. acceptance) and duties (e.g. contribution) perspective.

  8. Proposal of a service delivery integration index of home care for older persons: application in several European cities.

    NARCIS (Netherlands)

    Henrard, J.C.; Ankri, J.; Frijters, D.; Carpenter, I.; Topinkova, E.; Garms-Homolova, V.; Finne-Soveri, H.; Wergeland Sorbye, L.; Jonsson, P.V.; Ljunggren, G.; Schroll, M.; Wagner, C.; Bernabei, R.

    2006-01-01

    PURPOSE: To propose an integration index of home care delivery to older persons, to study its validity and to apply it to home care services of European cities. THEORY: Home care delivery integration was based on two dimensions referring to process-centred integration and organisational structure

  9. VENTILATION TECHNOLOGY SYSTEMS ANALYSIS

    Science.gov (United States)

    The report gives results of a project to develop a systems analysis of ventilation technology and provide a state-of-the-art assessment of ventilation and indoor air quality (IAQ) research needs. (NOTE: Ventilation technology is defined as the hardware necessary to bring outdoor ...

  10. Ventilation of nuclear facilities

    International Nuclear Information System (INIS)

    1982-01-01

    In this work an examination is made of ventilation problems in nuclear installations, of the fuel cycle or the handling of radioactive compounds. The study covers the detection of radioactive aerosols, purification, iodine trapping, ventilation equipment and its maintenance, engineering, safety of ventilation, fire efficiency, operation, regulations and normalization [fr

  11. Maternal personality and psychopathology as determinants of parenting behavior: a quantitative integration of two parenting literatures.

    Science.gov (United States)

    McCabe, Jennifer E

    2014-05-01

    A substantial literature has examined the association between parenting behavior and maternal psychological characteristics (i.e., personality and psychopathology). Although research has provided evidence indicating that personality and psychopathology are not independent of one another, parenting research has mainly focused on these characteristics separately. In the present study, I quantitatively integrated these literatures through meta-analytic path analysis. First, meta-analyses were conducted on articles, book chapters, and dissertations that examined associations between personality or psychopathology and warmth or control in mothers of children age 12 months or older. Using mixed-effects regression, meta-analyses revealed significant, small effect sizes suggesting that low levels of neuroticism and psychopathology and high levels of agreeableness, extraversion, and conscientiousness were associated with adaptive parenting. Moderator analyses indicated that variability among individual studies was partially explained by report method, study design, and conceptualizations of parenting behavior. Meta-analytic path analyses showed that the observed associations between maternal personality/psychopathology and parenting behaviors as reported in the literature may be explained by variance shared among these psychological characteristics. Furthermore, some maternal psychological characteristics explained a significantly larger portion of variance in parenting behavior than others. Findings supported the proposal that maternal personality and psychopathology are not independent in the associations they demonstrate with parenting behaviors and that these areas of research can be integrated. The present study is limited by including only mothers, excluding infants, and using cross-sectional analyses. However, results have implications for future conceptualizations of maternal psychological characteristics as determinants of parenting behaviors and for the refinement

  12. An integrative typology of personality assessment for aggression: implications for predicting counterproductive workplace behavior.

    Science.gov (United States)

    Bing, Mark N; Stewart, Susan M; Davison, H Kristl; Green, Philip D; McIntyre, Michael D; James, Lawrence R

    2007-05-01

    This study presents an integrative typology of personality assessment for aggression. In this typology, self-report and conditional reasoning (L. R. James, 1998) methodologies are used to assess 2 separate, yet often congruent, components of aggressive personalities. Specifically, self-report is used to assess explicit components of aggressive tendencies, such as self-perceived aggression, whereas conditional reasoning is used to assess implicit components, in particular, the unconscious biases in reasoning that are used to justify aggressive acts. These 2 separate components are then integrated to form a new theoretical typology of personality assessment for aggression. Empirical tests of the typology were subsequently conducted using data gathered across 3 samples in laboratory and field settings and reveal that explicit and implicit components of aggression can interact in the prediction of counterproductive, deviant, and prosocial behaviors. These empirical tests also reveal that when either the self-report or conditional reasoning methodology is used in isolation, the resulting assessment of aggression may be incomplete. Implications for personnel selection, team composition, and executive coaching are discussed. 2007 APA, all rights reserved

  13. Developing integrated health and social care services for older persons in Europe.

    Science.gov (United States)

    Leichsenring, Kai

    2004-01-01

    This paper is to distribute first results of the EU Fifth Framework Project 'Providing integrated health and social care for older persons-issues, problems and solutions' (PROCARE-http://www.euro.centre.org/procare/). The project's first phase was to identify different approaches to integration as well as structural, organisational, economic and social-cultural factors and actors that constitute integrated and sustainable care systems. It also served to retrieve a number of experiences, model ways of working and demonstration projects in the participating countries which are currently being analysed in order to learn from success-or failure-and to develop policy recommendations for the local, national and European level. The paper draws on existing definitions of integrated care in various countries and by various scholars. Given the context of an international comparative study it tries to avoid providing a single, ready-made definition but underlines the role of social care as part and parcel of this type of integrated care in the participating countries. The paper is based on national reports from researchers representing ten organisations (university institutes, consultancy firms, research institutes, the public and the NGO sector) from 9 European countries: Austria, Denmark, Finland, France, Germany, Greece, Italy, the Netherlands, and the UK. Literature reviews made intensive use of grey literature and evaluation studies in the context of at least five model ways of working in each country. As a result of the cross-national overview an attempt to classify different approaches and definitions is made and indicators of relative importance of the different instruments used in integrating health and social care services are provided. The cross-national overview shows that issues concerning co-ordination and integration of services are high on the agenda in most countries. Depending on the state of service development, various approaches and instruments can be

  14. [Neurally adjusted ventilatory assist (NAVA). A new mode of assisted mechanical ventilation].

    Science.gov (United States)

    Moerer, O; Barwing, J; Quintel, M

    2008-10-01

    The aim of mechanical ventilation is to assure gas exchange while efficiently unloading the respiratory muscles and mechanical ventilation is an integral part of the care of patients with acute respiratory failure. Modern lung protective strategies of mechanical ventilation include low-tidal-volume ventilation and the continuation of spontaneous breathing which has been shown to be beneficial in reducing atelectasis and improving oxygenation. Poor patient-ventilator interaction is a major issue during conventional assisted ventilation. Neurally adjusted ventilator assist (NAVA) is a new mode of mechanical ventilation that uses the electrical activity of the diaphragm (EAdi) to control the ventilator. First experimental studies showed an improved patient-ventilator synchrony and an efficient unloading of the respiratory muscles. Future clinical studies will have to show that NAVA is of clinical advantage when compared to conventional modes of assisted mechanical ventilation. This review characterizes NAVA according to current publications on this topic.

  15. Ventilation and ventilation/perfusion ratios

    International Nuclear Information System (INIS)

    Valind, S.O.

    1989-01-01

    The thesis is based on five different papers. The labelling of specific tracer compounds with positron emitting radionuclides enables a range of structural, physiological and biochemical parameters in the lung to be measured non-invasively, using positron emission tomography. This concept affords a unique opportunity for in vivo studies of different expressions of pulmonary pathophysiology at the regional level. The present thesis describes the application of positron emission tomography to the measurements of ventilation and ventilation/perfusion ratios using inert gas tracers, neon-19 and nitrogen-13 respectively. The validity of the methods applied was investigated with respect to the transport of inert gas tracers in the human lung. Both ventilation and the ventilation/perfusion ratio may be obtained with errors less than 10 % in the normal lung. In disease, however, errors may increase in those instances where the regional ventilation is very low or the intra-regional gas flow distribution is markedly nonuniform. A 2-3 fold increase in ventilation was demonstrated in normal nonsmoking subjects going from ventral to dorsal regions in the supine posture. These large regional differences could be well explained by the intrinsic elastic properties of lung tissue, considering the gravitational gradient in transpulmonary pressure. In asymptomatic smokers substantial regional ventilatroy abnormalities were found whilst the regional gas volume was similar in smokers and nonsmokers. The uncoupling between ventilation and gas volume probably reflects inflammatory changes in the airways. The regional differences in dV/dt/dQ/dt were relatively small and blood flow was largely matched to ventilation in the supine posture. However, small regions of lung with very low ventilation, unmatched by blood flow commonly exists in the most dependent parts of the lung in both smokers and nonsmokers. (29 illustrations, 7 tables, 113 references)

  16. Labour law treatment of health, work ability and personal integrity of the employees

    Directory of Open Access Journals (Sweden)

    Jovanović Predrag

    2014-01-01

    Full Text Available Health and working ability are assumptions of entering into and the existence of labour relations. The purpose of entering into and the existence of labour relations is in the organised and meaningful work, in the interest of the employer and the employee. The main obligation of the employee is to do their work personally in accordance with their health and work abilities. With regards to the said abilities, the employee is accepted to the work, and protection and maintaining of these abilities is the assumption of the survival and long lasting of the employment. This makes legitimate the need that the health and work ability be protected by law in a suitable way. To that effect, we can talk about protection of health of the employees and safety at work. Since health does not only mean the absence of illness, but also the overall social security of the employees at work and in connection with work, this and issue of insurance of different risks that follow work of the employee fall into measures of health protection. Finally, not only manpower, as an organic unity of health and work abilities, takes part in labour relations, but also the entire personality of the employee with the overall personal (moral and ethical integrity, which also on its part requires appropriate labour law treatment and protection (ban on discrimination, harassment, abuse, protection of personal data, etc..

  17. Viewpoint Integration for Hand-Based Recognition of Social Interactions from a First-Person View.

    Science.gov (United States)

    Bambach, Sven; Crandall, David J; Yu, Chen

    2015-11-01

    Wearable devices are becoming part of everyday life, from first-person cameras (GoPro, Google Glass), to smart watches (Apple Watch), to activity trackers (FitBit). These devices are often equipped with advanced sensors that gather data about the wearer and the environment. These sensors enable new ways of recognizing and analyzing the wearer's everyday personal activities, which could be used for intelligent human-computer interfaces and other applications. We explore one possible application by investigating how egocentric video data collected from head-mounted cameras can be used to recognize social activities between two interacting partners (e.g. playing chess or cards). In particular, we demonstrate that just the positions and poses of hands within the first-person view are highly informative for activity recognition, and present a computer vision approach that detects hands to automatically estimate activities. While hand pose detection is imperfect, we show that combining evidence across first-person views from the two social partners significantly improves activity recognition accuracy. This result highlights how integrating weak but complimentary sources of evidence from social partners engaged in the same task can help to recognize the nature of their interaction.

  18. Approaching multidimensional forms of knowledge through Personal Meaning Mapping in science integrating teaching outside the classroom

    DEFF Research Database (Denmark)

    Hartmeyer, Rikke; Bolling, Mads; Bentsen, Peter

    2017-01-01

    knowledge dimensions is important, especially in science teaching outside the classroom, where “hands-on” approaches and experiments are often part of teaching and require procedural knowledge, among other things. Therefore, this study investigates PMM as a method for exploring specific knowledge dimensions......Current research points to Personal Meaning Mapping (PMM) as a method useful in investigating students’ prior and current science knowledge. However, studies investigating PMM as a method for exploring specific knowledge dimensions are lacking. Ensuring that students are able to access specific...... in formal science education integrating teaching outside the classroom. We applied a case study design involving two schools and four sixth-grade classes. Data were collected from six students in each class who constructed personal meaning maps and were interviewed immediately after natural science...

  19. Nursing interventions for promoting self-care of persons with type 2 diabetes: an integrative review

    Directory of Open Access Journals (Sweden)

    Glória Yanne Martins de Oliveira

    2016-12-01

    Full Text Available This is an integrative review aiming at analyzing and identifying the evidence available in the literature on nursing interventions to promote self-care for persons with type 2 diabetes mellitus. Data collection occurred in the Latin American and Caribbean Health Sciences (LILACS, MEDLINE (via EBSCO, Cumulative Index to Nursing and Allied Health Literature (CINAHL and SCOPUS. The survey of articles occurred in July and August 2015 by two independent reviewers. The initial search identified 239 articles and eight of them met the selection criteria. Health education has emerged as a strategic field for implementing nursing interventions. Interventions with patient monitoring and that provided more care time were more satisfactory regarding self-care practices. The Orem's Self-Care Deficit Theory is indicated as a guide to direct the educator in self-care of diabetic persons.

  20. Need of integrated dietary therapy for persons with diabetes mellitus and "unhealthy" body constitution presentations.

    Science.gov (United States)

    Wong, Yee Chi Peggy

    2016-07-01

    From a perspective of Chinese medicine (CM), persons with unregulated "unhealthy" body constitution (BC) will further develop chronic diseases, such as diabetes mellitus (DM). Conventional dietary therapy with nutrition component has its limitations in the regulation of "unhealthy" BC. However, empirical evidence supports that "unhealthy" BC can be regulated with food natures and flavors from a perspective of CM. Presentations of "unhealthy" BC types, such as Yin-deficiency, Yang-deficiency and Yin-Yang-deficiency were found in persons with DM. It would be necessary to regulate the "unhealthy" BC presentations with integration of conventional dietary therapy and Chinese food therapy. The ultimate goal is to either stabilize glycaemic control or prevent the development of other chronic diseases leading to reduction of disease burden, such as disease-related poor quality of life, stress of healthcare professionals and the rising of healthcare cost.

  1. An Integrative Professional Theory and Practice Paper: Personal Reflections from the Journey through Clinical Pastoral Education.

    Science.gov (United States)

    McLean, Gillian

    2015-12-01

    CPE is an experience-based approach to learning spiritual care which combines clinical care with qualified supervision, in-class education and group reflection (CASC--http://www.spiritualcare.ca/). Through didactic seminars, group presentations and personal reading there is opportunity for the student to acquire, apply and integrate relevant theoretical information into their practice. Written for my CPE Specialist application, this paper describes how, through the course of advanced CPE education, I learn to utilize and integrate theory into my clinical work. Beginning with three strands--authenticity, listening and storytelling--I then discuss how the behavioural sciences and theology inform my practice. Focusing on empathy, I speak of the application of disclosure, the use of counter-transference as a diagnostic tool, and the place of therapeutic termination. Group theory, family systems theory, theological reflection, liturgical ministry, and multi-faith practices are considered. © The Author(s) 2015.

  2. The adjustments experienced by persons with an ostomy: an integrative review of the literature.

    Science.gov (United States)

    Torquato Lopes, Ana Patrícia Araujo; Decesaro, Maria das Neves

    2014-10-01

    The person with an ostomy may focus on the negative aspects of the stoma rather than its function to the detriment of self-image, acceptance of a new lifestyle, and ability to self-care. The purpose of this integrative literature review was to explore factors involved in the adaption process of persons with a gastrointestinal stoma with a focus on the role of nonspecialist professional nurses in the process. The authors searched the databases of the Virtual Health Library, the Latin American and Caribbean of Health Sciences Information System, the Scientific Electronic Library Online, the Spanish Bibliographic Index of Health Sciences, International Literature on Health Sciences (MEDLINE), and the Cochrane Library using the keywords ostomy, adaption, and nursing for full text articles in all languages published between 2008 and 2013. Of the 612 articles identified, 21 were not duplicates and met the inclusion criteria of availability of full text, published in the past 5 years, indexed, and covering the topic of stoma adaption; this literature was analyzed using Bardin's thematic analysis. Three categories emerged: experiences and adaption strategies employed by the person with a stoma, the role of the care provider, and education as a tool in healthcare. Persons with a stoma need time and support from caregivers, family, and friends to adjust to the changes and adapt to having a stoma. This includes the ability to overcome the stigma of appearance and activities involving social interaction. Caregivers and health professionals need to serve as information resources while encouraging care autonomy. The more informed the patient, the smoother the adaption process. The literature also suggests nursing education may affect caregiving. Further research to elucidate the adaption experienced by each person with an ostomy is needed to help the multidisciplinary team plan care appropriately.

  3. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D.N.; Nielsen, Peter V.

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... that the air is fully mixed. The objective of this work is to determine the influence of the location of a pollutant, temperature differences and whether the room is furnished or not. It is also investigated if it is sufficient to determine the mean concentration in the room to determine the personal exposure....... Full scale experiments along with a breathing thermal manikin (BTM) have been used. The results show that the location of the sources is of great importance, just as well as temperature differences. Furthermore, the concentration in the breathing zone showed large differences throughout the room....

  4. Arts Integration: A Strategy to Improve Teaching and Learning, Promote Personal Competencies, and Turn Around Low-Performing Schools

    Science.gov (United States)

    Biscoe, Belinda; Wilson, Kirk

    2015-01-01

    This paper connects the dots between arts integration, students' personal competencies, and school turnaround. Its thesis is that by intertwining art forms and methods with content in all subject areas, students learn more about art and the other subjects and build their personal competencies for learning. The paper includes the story of an…

  5. Complications of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Drašković Biljana

    2011-01-01

    Full Text Available Mechanical ventilation of the lungs, as an important therapeutic measure, cannot be avoided in critically ill patients. However, when machines take over some of vital functions there is always a risk of complications and accidents. Complications associated with mechanical ventilation can be divided into: 1 airway-associated complications; 2 complications in the response of patients to mechanical ventilation; and 3 complications related to the patient’s response to the device for mechanical ventilation. Complications of artificial airway may be related to intubation and extubation or the endotracheal tube. Complications of mechanical ventilation, which arise because of the patient’s response to mechanical ventilation, may primarily cause significant side effects to the lungs. During the last two decades it was concluded that mechanical ventilation can worsen or cause acute lung injury. Mechanical ventilation may increase the alveolar/capillary permeability by overdistension of the lungs (volutrauma, it can exacerbate lung damage due to the recruitment/derecruitment of collapsed alveoli (atelectrauma and may cause subtle damages due to the activation of inflammatory processes (biotrauma. Complications caused by mechanical ventilation, beside those involving the lungs, can also have significant effects on other organs and organic systems, and can be a significant factor contributing to the increase of morbidity and mortality in critically ill of mechanically ventilated patients. Complications are fortunately rare and do not occur in every patient, but due to their seriousness and severity they require extensive knowledge, experience and responsibility by health-care workers.

  6. Recommendations for mechanical ventilation of critically ill children from the Paediatric Mechanical Ventilation Consensus Conference (PEMVECC).

    Science.gov (United States)

    Kneyber, Martin C J; de Luca, Daniele; Calderini, Edoardo; Jarreau, Pierre-Henri; Javouhey, Etienne; Lopez-Herce, Jesus; Hammer, Jürg; Macrae, Duncan; Markhorst, Dick G; Medina, Alberto; Pons-Odena, Marti; Racca, Fabrizio; Wolf, Gerhard; Biban, Paolo; Brierley, Joe; Rimensberger, Peter C

    2017-12-01

    Much of the common practice in paediatric mechanical ventilation is based on personal experiences and what paediatric critical care practitioners have adopted from adult and neonatal experience. This presents a barrier to planning and interpretation of clinical trials on the use of specific and targeted interventions. We aim to establish a European consensus guideline on mechanical ventilation of critically children. The European Society for Paediatric and Neonatal Intensive Care initiated a consensus conference of international European experts in paediatric mechanical ventilation to provide recommendations using the Research and Development/University of California, Los Angeles, appropriateness method. An electronic literature search in PubMed and EMBASE was performed using a combination of medical subject heading terms and text words related to mechanical ventilation and disease-specific terms. The Paediatric Mechanical Ventilation Consensus Conference (PEMVECC) consisted of a panel of 15 experts who developed and voted on 152 recommendations related to the following topics: (1) general recommendations, (2) monitoring, (3) targets of oxygenation and ventilation, (4) supportive measures, (5) weaning and extubation readiness, (6) normal lungs, (7) obstructive diseases, (8) restrictive diseases, (9) mixed diseases, (10) chronically ventilated patients, (11) cardiac patients and (12) lung hypoplasia syndromes. There were 142 (93.4%) recommendations with "strong agreement". The final iteration of the recommendations had none with equipoise or disagreement. These recommendations should help to harmonise the approach to paediatric mechanical ventilation and can be proposed as a standard-of-care applicable in daily clinical practice and clinical research.

  7. Evaluation of ventilators for mouthpiece ventilation in neuromuscular disease.

    Science.gov (United States)

    Khirani, Sonia; Ramirez, Adriana; Delord, Vincent; Leroux, Karl; Lofaso, Frédéric; Hautot, Solène; Toussaint, Michel; Orlikowski, David; Louis, Bruno; Fauroux, Brigitte

    2014-09-01

    Daytime mouthpiece ventilation is a useful adjunct to nocturnal noninvasive ventilation (NIV) in patients with neuromuscular disease. The aims of the study were to analyze the practice of mouthpiece ventilation and to evaluate the performance of ventilators for mouthpiece ventilation. Practice of mouthpiece ventilation was assessed by a questionnaire, and the performance of 6 home ventilators with mouthpiece ventilation was assessed in a bench test using 24 different conditions per ventilator: 3 mouthpieces, a child and an adult patient profile, and 4 ventilatory modes. Questionnaires were obtained from 30 subjects (mean age 33 ± 11 y) using NIV for 12 ± 7 y. Fifteen subjects used NIV for > 20 h/day, and 11 were totally ventilator-dependent. The subject-reported benefits of mouthpiece ventilation were a reduction in dyspnea (73%) and fatigue (93%) and an improvement in speech (43%) and eating (27%). The bench study showed that none of the ventilators, even those with mouthpiece ventilation software, were able to deliver mouthpiece ventilation without alarms and/or autotriggering in each condition. Alarms and/or ineffective triggering or autotriggering were observed in 135 of the 198 conditions. The occurrence of alarms was more common with a large mouthpiece without a filter compared to a small mouthpiece with a filter (P ventilator. Subjects are satisfied with mouthpiece ventilation. Alarms are common with home ventilators, although less common in those with mouthpiece ventilation software. Improvements in home ventilators are needed to facilitate the expansion of mouthpiece ventilation. Copyright © 2014 by Daedalus Enterprises.

  8. An integrated Ka/Ku-band payload for personal, mobile and private business communications

    Science.gov (United States)

    Hayes, Edward J.; Keelty, J. Malcolm

    1991-01-01

    The Canadian Department of Communications has been studying options for a government-sponsored demonstration payload to be launched before the end of the century. A summary of the proposed system concepts and network architectures for providing an advanced private business network service at Ku-band and personal and mobile communications at Ka-band is presented. The system aspects addressed include coverage patterns, traffic capacity, and grade of service, multiple access options as well as special problems, such as Doppler in mobile applications. Earth terminal types and the advanced payload concept proposed in a feasibility study for the demonstration mission are described. This concept is a combined Ka-band/Ku-band payload which incorporates a number of advanced satellite technologies including a group demodulator to convert single-channel-per-carrier frequency division multiple access uplink signals to a time division multiplex downlink, on-board signal regeneration, and baseband switching to support packet switched data operation. The on-board processing capability of the payload provides a hubless VSAT architecture which permits single-hop full mesh interconnectivity. The Ka-band and Ku-band portions of the payload are fully integrated through an on-board switch, thereby providing the capability for fully integrated services, such as using the Ku-band VSAT terminals as gateway stations for the Ka-band personal and mobile communications services.

  9. Neuroscience in Psychiatry towards an integrative and personalized medicine in the DSM-V: a proposal

    Directory of Open Access Journals (Sweden)

    Erick Emmanuel Pérez Solís

    2009-05-01

    Full Text Available In the last Century the concept of health and, with it, medical science, has suffered a profound, conceptual and ontological change. However, this revolution has not reached, in the same way the field of mental health. In the next pages it will be shown, taking Major Depressive Disorder as a model, how it is possible and necessary, for the field ofpsychopathology (behavior and “mental” functions: rational, executive, cognitive, emotional, etc. the return to its medical origins, which will allow it to respond how the brain functions and its interactions with the rest of the organism and the environment, with the goal of obtaining patterns that will help us to define disease from an etiopathogenic point of view, so it would be possible to provide therapeutic options to theorgan in question. The time has come to ask if we have invented a science (psychiatry that has little to do with reality, and to answer that, the creation of multicentric data bases is proposed, in which biological (not just brain based, social, personal, clinical, etc. variables are integrated, to finally obtain correlations that allow us a reclassification of brain pathology that would be useful to offer integral and personalized treatments.

  10. Likelihood ratio-based integrated personal risk assessment of type 2 diabetes.

    Science.gov (United States)

    Sato, Noriko; Htun, Nay Chi; Daimon, Makoto; Tamiya, Gen; Kato, Takeo; Kubota, Isao; Ueno, Yoshiyuki; Yamashita, Hidetoshi; Fukao, Akira; Kayama, Takamasa; Muramatsu, Masaaki

    2014-01-01

    To facilitate personalized health care for multifactorial diseases, risks of genetic and clinical/environmental factors should be assessed together for each individual in an integrated fashion. This approach is possible with the likelihood ratio (LR)-based risk assessment system, as this system can incorporate manifold tests. We examined the usefulness of this system for assessing type 2 diabetes (T2D). Our system employed 29 genetic susceptibility variants, body mass index (BMI), and hypertension as risk factors whose LRs can be estimated from openly available T2D association data for the Japanese population. The pretest probability was set at a sex- and age-appropriate population average of diabetes prevalence. The classification performance of our LR-based risk assessment was compared to that of a non-invasive screening test for diabetes called TOPICS (with score based on age, sex, family history, smoking, BMI, and hypertension) using receiver operating characteristic analysis with a community cohort (n = 1263). The area under the receiver operating characteristic curve (AUC) for the LR-based assessment and TOPICS was 0.707 (95% CI 0.665-0.750) and 0.719 (0.675-0.762), respectively. These AUCs were much higher than that of a genetic risk score constructed using the same genetic susceptibility variants, 0.624 (0.574-0.674). The use of ethnically matched LRs is necessary for proper personal risk assessment. In conclusion, although LR-based integrated risk assessment for T2D still requires additional tests that evaluate other factors, such as risks involved in missing heritability, our results indicate the potential usability of LR-based assessment system and stress the importance of stratified epidemiological investigations in personalized medicine.

  11. Getting personal: can systems medicine integrate scientific and humanistic conceptions of the patient?

    Science.gov (United States)

    Vogt, Henrik; Ulvestad, Elling; Eriksen, Thor Eirik; Getz, Linn

    2014-12-01

    The practicing doctor, and most obviously the primary care clinician who encounters the full complexity of patients, faces several fundamental but intrinsically related theoretical and practical challenges - strongly actualized by so-called medically unexplained symptoms (MUS) and multi-morbidity. Systems medicine, which is the emerging application of systems biology to medicine and a merger of molecular biomedicine, systems theory and mathematical modelling, has recently been proposed as a primary care-centered strategy for medicine that promises to meet these challenges. Significantly, it has been proposed to do so in a way that at first glance may seem compatible with humanistic medicine. More specifically, it is promoted as an integrative, holistic, personalized and patient-centered approach. In this article, we ask whether and to what extent systems medicine can provide a comprehensive conceptual account of and approach to the patient and the root causes of health problems that can be reconciled with the concept of the patient as a person, which is an essential theoretical element in humanistic medicine. We answer this question through a comparative analysis of the theories of primary care doctor Eric Cassell and systems biologist Denis Noble. We argue that, although systems biological concepts, notably Noble's theory of biological relativity and downward causation, are highly relevant for understanding human beings and health problems, they are nevertheless insufficient in fully bridging the gap to humanistic medicine. Systems biologists are currently unable to conceptualize living wholes, and seem unable to account for meaning, value and symbolic interaction, which are central concepts in humanistic medicine, as constraints on human health. Accordingly, systems medicine as currently envisioned cannot be said to be integrative, holistic, personalized or patient-centered in a humanistic medical sense. © 2014 The Authors. Journal of Evaluation in Clinical

  12. 30 CFR 57.14213 - Ventilation and shielding for welding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Ventilation and shielding for welding. 57.14213... welding. (a) Welding operations shall be shielded when performed at locations where arc flash could be hazardous to persons. (b) All welding operations shall be well-ventilated. ...

  13. Protective garment ventilation system

    Science.gov (United States)

    Lang, R. (Inventor)

    1970-01-01

    A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

  14. Ventilation rates and health

    DEFF Research Database (Denmark)

    Sundell, Jan; Levin, H; Nazaroff, W W

    2011-01-01

    and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes...... studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants...

  15. Ventilation of uranium mines

    International Nuclear Information System (INIS)

    Francois, Y.; Pradel, J.; Zettwoog, P.; Dumas, M.

    1975-01-01

    In the first part of the paper the authors describe the ventilation of French mines in terms of the primary ventilation system, which brings the outside air close to the working places using the overall structure of the mine to form the airways, and the secondary ventilation system, which is for the distribution of the primary air or for the ventilation of the development drifts and blind tunnels. Brief mention is made of the French regulations on the ventilation of mines in general and uranium mines in particular. The authors describe the equipment used and discuss the installed capacities and air flow per man and per working place. The difficulties encountered in properly ventilating various types of working places are mentioned, such as sub-level development drifts, reinforced stopes, and storage chambers with an artificial crown. The second part of the paper is devoted to computer calculations of the primary ventilation system. It is explained why the Commissariat a l'energie atomique has found it necessary to make these calculations. Without restating the mathematical theories underlying the methods employed, the authors demonstrate how simple measuring instruments and a small-size computer can be used to solve the ventilation problems arising in French mines. Emphasis is given to the layout of the ventilation system and to air flow and negative pressure measurements at the base of the mine. The authors show how calculations can be applied to new heading operations, a change in resistance, the replacement or addition of a ventilator, and a new air inlet or outlet. The authors come to the conclusion that since ventilation is at present the most reliable way of avoiding the pollution of mines, a thorough knowledge of the capabilities in this respect can often help improve working conditions. Despite the progress made, however, constant surveillance of the ventilation systems in uranium mines by a separate team with no responsibility for production problems is

  16. Ventilation of uranium mines

    International Nuclear Information System (INIS)

    Francois, Y.; Pradel, J.; Zettwoog, P.; Dumas, M.

    1975-01-01

    In the first part of the paper the authors describe the ventilation of French mines in terms of the primary ventilation system, which brings the outside air close to the working places using the overall structure of the mine to form the airways, and the secondary ventilation system, which is for the distribution of the primary air or for the ventilation of the development drifts and blind tunnels. Brief mention is made of the French regulations on the ventilation of mines in general and uranium mines in particular. The authors describe the equipment used and discuss the installed capacities and air flow per man and per working place. The difficulties encountered in properly ventilating various types of working places are mentioned, such as sublevel development drifts, reinforced stopes, and storage chambers with an artificial crown. The second part of the paper is devoted to computer calculations of the primary ventilation system. It is explained why the Commissariat a l'energie atomique has found it necessary to make these calculations. Without restating the mathematical theories underlying the methods employed, the authors demonstrate how simple measuring instruments and a small-size computer can be used to solve the ventilation problems arising in French mines. Emphasis is given to the layout of the ventilation system and to air flow and negative pressure measurements at the base of the mine. The authors show how calculations can be applied to new heading operations, a change in resistance, the replacement or addition of a ventilator, and a new air inlet or outlet. The authors come to the conclusion that since ventilation is at present the most reliable way of avoiding the pollution of mines, a thorough knowledge of the capabilities in this respect can often help improve working conditions. Despite the progress made, however, constant surveillance of the ventilation systems in uranium mines by a separate team with no responsibility for production problems is

  17. Design Principles for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system -Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and - principles are discussed and illustrated by four building examples....

  18. Natural Ventilation in Atria

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Hendriksen, Ole Juhl

    This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions.......This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions....

  19. The Integral Abilities of the Personality as the Subject Matt er of Psychological Research

    Directory of Open Access Journals (Sweden)

    Anatoly V. Karpov

    2012-01-01

    Full Text Available This article discusses some key methodological and theoretical issues of the fundamental,common psychological problem of abilities. It shows that there is a lackof modern ideas about the content of the subject matter of the psychology ofabilities and, therefore, a need for enrichment. In this conceptual expansion itis necessary to differentiate a special, qualitatively specific class of abilities – theintegral abilities of the individual. All these abilities are differentiated on the basisof the most promising paradigm in the development of the ability problem– thefunctional-genetic paradigm – and are related to one of the basic classes of mentalprocesses – the integral mental processes (goal formation, anticipation, decisionmaking, programming, prognosis, planning, control, self-control. In the article adetailed psychological characteristic of the basic integral abilities is presented, asa result of which the correspondence of these abilities to all features and criteriaof abilities as such is proved. The necessity of using the structural-level approachin relation to the ability problem is shown, and a holistic, generalized hierarchy ofthe basic ability classes is proposed. This hierarchy has three main levels. At thehighest level the general abilities are located; at the basic level are the specificabilities of a person. The integral abilities are located between these two levelsand thus form a mesolevel in the general hierarchical organization of the abilitiesof the individual.

  20. Becoming who you are: An integrative review of self-determination theory and personality systems interactions theory.

    Science.gov (United States)

    Koole, Sander L; Schlinkert, Caroline; Maldei, Tobias; Baumann, Nicola

    2018-03-10

    One of the enduring missions of personality science is to unravel what it takes to become a fully functioning person. In the present article, the authors address this matter from the perspectives of self-determination theory (SDT) and personality systems interactions (PSI) theory. SDT (a) is rooted in humanistic psychology; (b) has emphasized a first-person perspective on motivation and personality; (c) posits that the person, supported by the social environment, naturally moves toward growth through the satisfaction of basic psychological needs for autonomy, competence, and relatedness. PSI theory (a) is rooted in German volition psychology; (b) has emphasized a third-person perspective on motivation and personality; and (c) posits that a fully functioning person can form and enact difficult intentions and integrate new experiences, and that such competencies are facilitated by affect regulation. The authors review empirical support for SDT and PSI theory, their convergences and divergences, and how the theories bear on recent empirical research on internalization, vitality, and achievement flow. The authors conclude that SDT and PSI theory offer complementary insights into developing a person's full potential. © 2018 The Authors. Journal of Personality Published by Wiley Periodicals, Inc.

  1. 30 CFR 75.324 - Intentional changes in the ventilation system.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Intentional changes in the ventilation system... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.324 Intentional changes in the ventilation system. (a) A person designated by the operator shall supervise any...

  2. Integrating Learning Styles and Personality Traits into an Affective Model to Support Learner's Learning

    Science.gov (United States)

    Leontidis, Makis; Halatsis, Constantin

    The aim of this paper is to present a model in order to integrate the learning style and the personality traits of a learner into an enhanced Affective Style which is stored in the learner’s model. This model which can deal with the cognitive abilities as well as the affective preferences of the learner is called Learner Affective Model (LAM). The LAM is used to retain learner’s knowledge and activities during his interaction with a Web-based learning environment and also to provide him with the appropriate pedagogical guidance. The proposed model makes use of an ontological approach in combination with the Bayesian Network model and contributes to the efficient management of the LAM in an Affective Module.

  3. An Integrated Framework to Achieve Interoperability in Person-Centric Health Management

    Directory of Open Access Journals (Sweden)

    Fabio Vergari

    2011-01-01

    Full Text Available The need for high-quality out-of-hospital healthcare is a known socioeconomic problem. Exploiting ICT's evolution, ad-hoc telemedicine solutions have been proposed in the past. Integrating such ad-hoc solutions in order to cost-effectively support the entire healthcare cycle is still a research challenge. In order to handle the heterogeneity of relevant information and to overcome the fragmentation of out-of-hospital instrumentation in person-centric healthcare systems, a shared and open source interoperability component can be adopted, which is ontology driven and based on the semantic web data model. The feasibility and the advantages of the proposed approach are demonstrated by presenting the use case of real-time monitoring of patients' health and their environmental context.

  4. Integrating Personalized Technology in Toxicology: Sensors, Smart Glass, and Social Media Applications in Toxicology Research.

    Science.gov (United States)

    Carreiro, Stephanie; Chai, Peter R; Carey, Jennifer; Chapman, Brittany; Boyer, Edward W

    2017-06-01

    Rapid proliferation of mobile technologies in social and healthcare spaces create an opportunity for advancement in research and clinical practice. The application of mobile, personalized technology in healthcare, referred to as mHealth, has not yet become routine in toxicology. However, key features of our practice environment, such as frequent need for remote evaluation, unreliable historical data from patients, and sensitive subject matter, make mHealth tools appealing solutions in comparison to traditional methods that collect retrospective or indirect data. This manuscript describes the features, uses, and costs associated with several of common sectors of mHealth research including wearable biosensors, ingestible biosensors, head-mounted devices, and social media applications. The benefits and novel challenges associated with the study and use of these applications are then discussed. Finally, opportunities for further research and integration are explored with a particular focus on toxicology-based applications.

  5. Styret naturlig ventilation

    DEFF Research Database (Denmark)

    Morsing, S.; Strøm, J.S.

    Publikationen præsenterer et generelt dimensioneringsgrundlag for naturlig ventilation i husdyrstalde. Det er kontrolleret ved forsøg i slagtesvinestalde, hvor det ligeledes er undersøgt hvilken temperaturstabilitet, der kan opnås ved naturlig ventilation, samt produktions- og adfærdsmæssige...

  6. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation (BSC), Somerville, MA (United States); Lstiburek, J. [Building Science Corporation (BSC), Somerville, MA (United States); Bergey, D. [Building Science Corporation (BSC), Somerville, MA (United States)

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  7. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Nielsen, Peter V.

    2014-01-01

    As a novel air distribution system, diffuse ceiling ventilation combines the suspended acoustic ceiling with ventilation supply. Due to the low-impulse supply from the large ceiling area, the system does not generate draught when supplying cold air. However, heat sources play an important role...

  8. Prediction of leisure-time walking: an integration of social cognitive, perceived environmental, and personality factors

    Directory of Open Access Journals (Sweden)

    Blanchard Chris M

    2007-10-01

    Full Text Available Abstract Background Walking is the primary focus of population-based physical activity initiatives but a theoretical understanding of this behaviour is still elusive. The purpose of this study was to integrate personality, the perceived environment, and planning into a theory of planned behaviour (TPB framework to predict leisure-time walking. Methods Participants were a random sample (N = 358 of Canadian adults who completed measures of the TPB, planning, perceived neighbourhood environment, and personality at Time 1 and self-reported walking behaviour two months later. Results Analyses using structural equation modelling provided evidence that leisure-time walking is largely predicted by intention (standardized effect = .42 with an additional independent contribution from proximity to neighbourhood retail shops (standardized effect = .18. Intention, in turn, was predicted by attitudes toward walking and perceived behavioural control. Effects of perceived neighbourhood aesthetics and walking infrastructure on walking were mediated through attitudes and intention. Moderated regression analysis showed that the intention-walking relationship was moderated by conscientiousness and proximity to neighbourhood recreation facilities but not planning. Conclusion Overall, walking behaviour is theoretically complex but may best be addressed at a population level by facilitating strong intentions in a receptive environment even though individual differences may persist.

  9. OpenDrop: An Integrated Do-It-Yourself Platform for Personal Use of Biochips

    Directory of Open Access Journals (Sweden)

    Mirela Alistar

    2017-05-01

    Full Text Available Biochips, or digital labs-on-chip, are developed with the purpose of being used by laboratory technicians or biologists in laboratories or clinics. In this article, we expand this vision with the goal of enabling everyone, regardless of their expertise, to use biochips for their own personal purposes. We developed OpenDrop, an integrated electromicrofluidic platform that allows users to develop and program their own bio-applications. We address the main challenges that users may encounter: accessibility, bio-protocol design and interaction with microfluidics. OpenDrop consists of a do-it-yourself biochip, an automated software tool with visual interface and a detailed technique for at-home operations of microfluidics. We report on two years of use of OpenDrop, released as an open-source platform. Our platform attracted a highly diverse user base with participants originating from maker communities, academia and industry. Our findings show that 47% of attempts to replicate OpenDrop were successful, the main challenge remaining the assembly of the device. In terms of usability, the users managed to operate their platforms at home and are working on designing their own bio-applications. Our work provides a step towards a future in which everyone will be able to create microfluidic devices for their personal applications, thereby democratizing parts of health care.

  10. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  11. Realtime mine ventilation simulation

    International Nuclear Information System (INIS)

    McDaniel, K.H.

    1997-01-01

    This paper describes the development of a Windows based, interactive mine ventilation simulation software program at the Waste Isolation Pilot Plant (WIPP). To enhance the operation of the underground ventilation system, Westinghouse Electric Corporation developed the program called WIPPVENT. While WIPPVENT includes most of the functions of the commercially available simulation program VNETPC and uses the same subroutine to calculate airflow distributions, the user interface has been completely rewritten as a Windows application with screen graphics. WIPPVENT is designed to interact with WIPP ventilation monitoring systems through the sitewise Central monitoring System. Data can be continuously collected from the Underground Ventilation Remote Monitoring and Control System (e.g., air quantity and differential pressure) and the Mine Weather Stations (psychrometric data). Furthermore, WIPPVENT incorporates regulator characteristic curves specific to the site. The program utilizes this data to create and continuously update a REAL-TIME ventilation model. This paper discusses the design, key features, and interactive capabilities of WIPPVENT

  12. An Integrative Analysis of the Narcissistic Personality Inventory and the Hypomanic Personality Scale: Implications for Construct Validity.

    Science.gov (United States)

    Stanton, Kasey; Daly, Elizabeth; Stasik-O'Brien, Sara M; Ellickson-Larew, Stephanie; Clark, Lee Anna; Watson, David

    2017-09-01

    The primary goal of this study was to explicate the construct validity of the Narcissistic Personality Inventory (NPI) and the Hypomanic Personality Scale (HPS) by examining their relations both to each other and to measures of personality and psychopathology in a community sample ( N = 255). Structural evidence indicates that the NPI is defined by Leadership/Authority, Grandiose Exhibitionism, and Entitlement/Exploitativeness factors, whereas the HPS is characterized by specific dimensions reflecting Social Vitality, Mood Volatility, and Excitement. Our results establish that (a) factor-based subscales from these instruments display divergent patterns of relations that are obscured when relying exclusively on total scores and (b) some NPI and HPS subscales more clearly tap content specifically relevant to narcissism and mania, respectively, than others. In particular, our findings challenge the construct validity of the NPI Leadership/Authority and HPS Social Vitality subscales, which appear to assess overlapping assertiveness content that is largely adaptive in nature.

  13. Integrating local urban climate modelling and mobile sensor data for personal exposure assessments in the context of urban heat island effect

    Science.gov (United States)

    Ueberham, Maximilian; Hertel, Daniel; Schlink, Uwe

    2017-04-01

    ) and the surrounding nesting area (rural area). Preparing for the outdoor application of mobile MSDs we tested their accuracy and performance between several MSDs and reliable sophisticated devices under laboratory conditions. We found that variations mainly depend on the device design and technology (e.g. active/passive ventilation). The standard deviation of the temperature records was quite stable over the whole range of values and the MSDs proved to be applicable for the purpose of our study. In conclusion the benefit of integrating mobile data and micrometeorological predictions is manifold. Mobile data can be used for the investigation of personal exposure in the context of heat stress and for the verification and training of micrometeorological models. Otherwise, model predictions can identify local areas of special climate interest where additional mobile measurements would be beneficial to provide new information for mitigation and adaptation actions.

  14. Flexible Conductive Composite Integrated with Personal Earphone for Wireless, Real-Time Monitoring of Electrophysiological Signs.

    Science.gov (United States)

    Lee, Joong Hoon; Hwang, Ji-Young; Zhu, Jia; Hwang, Ha Ryeon; Lee, Seung Min; Cheng, Huanyu; Lee, Sang-Hoon; Hwang, Suk-Won

    2018-06-14

    We introduce optimized elastomeric conductive electrodes using a mixture of silver nanowires (AgNWs) with carbon nanotubes/polydimethylsiloxane (CNTs/PDMS), to build a portable earphone type of wearable system that is designed to enable recording electrophysiological activities as well as listening to music at the same time. A custom-built, plastic frame integrated with soft, deformable fabric-based memory foam of earmuffs facilitates essential electronic components, such as conductive elastomers, metal strips, signal transducers and a speaker. Such platform incorporates with accessory cables to attain wireless, real-time monitoring of electrical potentials whose information can be displayed on a cell phone during outdoor activities and music appreciation. Careful evaluations on experimental results reveal that the performance of fabricated dry electrodes are comparable to that of commercial wet electrodes, and position-dependent signal behaviors provide a route toward accomplishing maximized signal quality. This research offers a facile approach for a wearable healthcare monitor via integration of soft electronic constituents with personal belongings.

  15. Integrated Pathology Informatics Enables High-Quality Personalized and Precision Medicine: Digital Pathology and Beyond.

    Science.gov (United States)

    Volynskaya, Zoya; Chow, Hung; Evans, Andrew; Wolff, Alan; Lagmay-Traya, Cecilia; Asa, Sylvia L

    2018-03-01

    - The critical role of pathology in diagnosis, prognosis, and prediction demands high-quality subspecialty diagnostics that integrates information from multiple laboratories. - To identify key requirements and to establish a systematic approach to providing high-quality pathology in a health care system that is responsible for services across a large geographic area. - This report focuses on the development of a multisite pathology informatics platform to support high-quality surgical pathology and hematopathology using a sophisticated laboratory information system and whole slide imaging for histology and immunohistochemistry, integrated with ancillary tools, including electron microscopy, flow cytometry, cytogenetics, and molecular diagnostics. - These tools enable patients in numerous geographic locations access to a model of subspecialty pathology that allows reporting of every specimen by the right pathologist at the right time. The use of whole slide imaging for multidisciplinary case conferences enables better communication among members of patient care teams. The system encourages data collection using a discrete data synoptic reporting module, has implemented documentation of quality assurance activities, and allows workload measurement, providing examples of additional benefits that can be gained by this electronic approach to pathology. - This approach builds the foundation for accurate big data collection and high-quality personalized and precision medicine.

  16. Integrated employee assistance program/managed behavioral health plan utilization by persons with substance use disorders.

    Science.gov (United States)

    Merrick, Elizabeth S Levy; Hodgkin, Dominic; Hiatt, Deirdre; Horgan, Constance M; Greenfield, Shelly F; McCann, Bernard

    2011-04-01

    New federal parity and health reform legislation, promising increased behavioral health care access and a focus on prevention, has heightened interest in employee assistance programs (EAPs). This study investigated service utilization by persons with a primary substance use disorder (SUD) diagnosis in a managed behavioral health care (MBHC) organization's integrated EAP/MBHC product (N = 1,158). In 2004, 25.0% of clients used the EAP first for new treatment episodes. After initial EAP utilization, 44.4% received no additional formal services through the plan, and 40.4% received regular outpatient services. Overall, outpatient care, intensive outpatient/day treatment, and inpatient/residential detoxification were most common. About half of the clients had co-occurring psychiatric diagnoses. Mental health service utilization was extensive. Findings suggest that for service users with primary SUD diagnoses in an integrated EAP/MBHC product, the EAP benefit plays a key role at the front end of treatment and is often only one component of treatment episodes. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Integrated EAP/Managed Behavioral Health Plan Utilization by Persons with Substance Use Disorders

    Science.gov (United States)

    Levy Merrick, Elizabeth S.; Hodgkin, Dominic; Hiatt, Deirdre; Horgan, Constance M.; Greenfield, Shelly F.; McCann, Bernard

    2011-01-01

    New federal parity and health reform legislation, promising increased behavioral health care access and a focus on prevention, has heightened interest in employee assistance programs (EAPs). This study investigated service utilization by persons with a primary substance use disorder (SUD) diagnosis in a managed behavioral healthcare organization's integrated EAP/managed behavioral health care product (N=1,158). In 2004, 25.0% of clients used the EAP first for new treatment episodes. After initial EAP utilization, 44.4% received no additional formal services through the plan and 40.4% received regular outpatient services. Overall, outpatient care, intensive outpatient/day treatment, and inpatient/residential detoxification were most common. About half of clients had co-occurring psychiatric diagnoses. Mental health service utilization was extensive. Findings suggest that for service users with primary SUD diagnoses in an integrated EAP/MBHC product, the EAP benefit plays a key role at the front end of treatment and is often only one component of treatment episodes. PMID:21185684

  18. Developing integrated health and social care services for older persons in Europe

    Directory of Open Access Journals (Sweden)

    Kai Leichsenring

    2004-09-01

    the state of service development, various approaches and instruments can be observed. Different national frameworks, in particular with respect to financing and organisation, systemic development, professionalisation and professional cultures, basic societal values (family ethics, and political approaches have to be taken into account during the second phase of PROCARE during which transversal and transnational analysis will be undertaken based on an in-depth analysis of two model ways of working in each country. Discussion: Far from a European vision concerning integrated care, national health and social care systems remain—at best—loosely coupled systems that are facing increasing difficulties, given the current challenges, in particular in long-term care for older persons: increasing marketisation, lack of managerial knowledge (co-operation, co-ordination, shortage of care workers and a general trend towards down-sizing of social care services continue to hamper the first tentative pathways towards integrated care systems.

  19. Integrating precision medicine in the study and clinical treatment of a severely mentally ill person

    Directory of Open Access Journals (Sweden)

    Jason A. O’Rawe

    2013-10-01

    Full Text Available Background. In recent years, there has been an explosion in the number of technical and medical diagnostic platforms being developed. This has greatly improved our ability to more accurately, and more comprehensively, explore and characterize human biological systems on the individual level. Large quantities of biomedical data are now being generated and archived in many separate research and clinical activities, but there exists a paucity of studies that integrate the areas of clinical neuropsychiatry, personal genomics and brain-machine interfaces.Methods. A single person with severe mental illness was implanted with the Medtronic Reclaim® Deep Brain Stimulation (DBS Therapy device for Obsessive Compulsive Disorder (OCD, targeting his nucleus accumbens/anterior limb of the internal capsule. Programming of the device and psychiatric assessments occurred in an outpatient setting for over two years. His genome was sequenced and variants were detected in the Illumina Whole Genome Sequencing Clinical Laboratory Improvement Amendments (CLIA-certified laboratory.Results. We report here the detailed phenotypic characterization, clinical-grade whole genome sequencing (WGS, and two-year outcome of a man with severe OCD treated with DBS. Since implantation, this man has reported steady improvement, highlighted by a steady decline in his Yale-Brown Obsessive Compulsive Scale (YBOCS score from ∼38 to a score of ∼25. A rechargeable Activa RC neurostimulator battery has been of major benefit in terms of facilitating a degree of stability and control over the stimulation. His psychiatric symptoms reliably worsen within hours of the battery becoming depleted, thus providing confirmatory evidence for the efficacy of DBS for OCD in this person. WGS revealed that he is a heterozygote for the p.Val66Met variant in BDNF, encoding a member of the nerve growth factor family, and which has been found to predispose carriers to various psychiatric illnesses. He

  20. Use of integrated dual disorder treatment via assertive community treatment versus clinical case management for persons with co-occurring disorders and antisocial personality disorder.

    Science.gov (United States)

    Frisman, Linda K; Mueser, Kim T; Covell, Nancy H; Lin, Hsiu-Ju; Crocker, Anne; Drake, Robert E; Essock, Susan M

    2009-11-01

    We conducted secondary analyses of data from a randomized trial testing the effectiveness of Assertive Community Treatment (ACT) in delivery of integrated dual disorder treatment (IDDT) to explore the impact of IDDT delivered through ACT teams compared with standard clinical case management for dually-disordered persons with and without antisocial personality disorder (ASPD). This analysis included 36 individuals with ASPD and 88 individuals without ASPD. Participants with ASPD assigned to ACT showed a significantly greater reduction in alcohol use and were less likely to go to jail than those in standard clinical case management, whereas participants without ASPD did not differ between the 2 case management approaches. There were no significant differences for other substance use or criminal justice outcomes. This study provides preliminary evidence that persons with co-occurring serious mental illness, substance use disorders, and ASPD may benefit from delivery of IDDT through ACT teams.

  1. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  2. Ventilation of nuclear rooms and operators' protection

    International Nuclear Information System (INIS)

    Vavasseur, C.

    1985-01-01

    Ventilation systems are designed to guarantee air replacement in rooms so as to evacuate gases, odors and aerosols liable to be produced therein. This air is conditioned, filtered, heated, and the relative humidity checked. At the outlet, a filtration system adapted to the type of effluent prevents the external dispersion of toxic substances. Ventilation is defined by the air change time. A comfort rule recommends reducing the velocities reaching the person present in less than 0.2 m/sec. This reduction is achieved by adjusting the natural property of the jets, induction, by means of diffusers placed at the vents

  3. Comparison of 4-Dimensional Computed Tomography Ventilation With Nuclear Medicine Ventilation-Perfusion Imaging: A Clinical Validation Study

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevgeniy; Koo, Phillip J.; Castillo, Richard; Castillo, Edward; Guerrero, Thomas; Gaspar, Laurie E.; Miften, Moyed; Kavanagh, Brian D.

    2014-01-01

    analyzed on a regional level. Our study presents an important step for the integration of 4DCT-ventilation into thoracic clinical practice

  4. An Other Perspective on Personality: Meta-Analytic Integration of Observers' Accuracy and Predictive Validity

    Science.gov (United States)

    Connelly, Brian S.; Ones, Deniz S.

    2010-01-01

    The bulk of personality research has been built from self-report measures of personality. However, collecting personality ratings from other-raters, such as family, friends, and even strangers, is a dramatically underutilized method that allows better explanation and prediction of personality's role in many domains of psychology. Drawing…

  5. Personalizing oncology treatments by predicting drug efficacy, side-effects, and improved therapy: mathematics, statistics, and their integration.

    Science.gov (United States)

    Agur, Zvia; Elishmereni, Moran; Kheifetz, Yuri

    2014-01-01

    Despite its great promise, personalized oncology still faces many hurdles, and it is increasingly clear that targeted drugs and molecular biomarkers alone yield only modest clinical benefit. One reason is the complex relationships between biomarkers and the patient's response to drugs, obscuring the true weight of the biomarkers in the overall patient's response. This complexity can be disentangled by computational models that integrate the effects of personal biomarkers into a simulator of drug-patient dynamic interactions, for predicting the clinical outcomes. Several computational tools have been developed for personalized oncology, notably evidence-based tools for simulating pharmacokinetics, Bayesian-estimated tools for predicting survival, etc. We describe representative statistical and mathematical tools, and discuss their merits, shortcomings and preliminary clinical validation attesting to their potential. Yet, the individualization power of mathematical models alone, or statistical models alone, is limited. More accurate and versatile personalization tools can be constructed by a new application of the statistical/mathematical nonlinear mixed effects modeling (NLMEM) approach, which until recently has been used only in drug development. Using these advanced tools, clinical data from patient populations can be integrated with mechanistic models of disease and physiology, for generating personal mathematical models. Upon a more substantial validation in the clinic, this approach will hopefully be applied in personalized clinical trials, P-trials, hence aiding the establishment of personalized medicine within the main stream of clinical oncology. © 2014 Wiley Periodicals, Inc.

  6. The effect of sports on level of community integration as reported by persons with spinal cord injury.

    Science.gov (United States)

    Hanson, C S; Nabavi, D; Yuen, H K

    2001-01-01

    The purpose of this study was to determine whether participation in sports by persons with spinal cord injuries (SCIs) affected level of community integration as defined by the World Health Organization and as measured by the Craig Handicap Assessment and Reporting Technique (CHART). Forty-eight participants were recruited from a camp for persons with physical disabilities as well as from SCI support groups. Participants were divided into groups of athletes (n = 30) and nonathletes (n = 18) on the basis of their self-reported level of sports participation. Athletes scored significantly higher on four of five subsections of the CHART (physical independence, mobility, occupation, social integration), indicating greater levels of community integration than nonathletes. These findings extend the literature outlining the physical and psychological benefits of sports. Occupational therapists have a unique opportunity to use the occupation of sports to integrate the roots of the profession with the cultural demands of society.

  7. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  8. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    OpenAIRE

    Sherman, Max H.

    2011-01-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outd...

  9. Conceptual analysis of social responsibility of the person and its integration in pharmaceutical practice

    Directory of Open Access Journals (Sweden)

    N. O. Tkachenko

    2017-12-01

    Full Text Available The modern development of the social policy of pharmaceutical organizations in Ukraine, focused on the needs of society, is characterized by the lag in practical implementation of appropriate social responsibility (SR from the increased interest of pharmaceutical scientists in its various aspects. Issues of personal identity, its role and place in the system of socially responsible behavior of pharmaceutical organizations and the professional activity of pharmacists remain insufficiently studied. The purpose research. Conceptual analysis of the social responsibility of the individual with the integration into pharmacy and the rationale for strategic directions for the formation of social responsibility as a professional competence of pharmacists in the system of continuous pharmaceutical education. Materials and methods. We used the methods of information retrieval, comparison, systematization, analysis, synthesis and modeling. Materials for research were publications of fundamental and applied research of domestic and foreign scientists on issues of social responsibility, international standards. Results. Personality in the process of activity is both the subject and the object of responsibility, since social responsibility is a condition for interaction between the individual and the society. The social responsibility of pharmacy specialists directed to primary and secondary social groups, society and the individual, as well as to oneself. In the latter case, the self-concept is important, that is, the individual's complete self-image and the readiness of the individual to act in a certain way in certain situations, as well as the possible social roles of the pharmacist. The process of forming the social responsibility of pharmacy specialists is a complex level system that continuously educates, develops and improves the skill of social responsibility throughout professional life. Conclusions. On the basis of theoretical generalization of the

  10. Design, Implementation & Assessment of Local Exhaust Ventilation System and dust collectors for crushing unit

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani shahna

    2015-09-01

    Full Text Available Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust ventilation system based on standards and guides was designed and implemented after field study of the processes and sources of air pollutants. A set comprised of the four parallel cyclones (Stairmand model and a new design of the scrubber had been used for dust control. After set-up of systems, its effectiveness in reducing the exposure of workers in the workshops and dust collecting were assessed. Results: Test results were significant differences between the concentration of particles in both on and off the ventilation system revealed (P <0.05. The system has been implemented as means of personal exposure to pollutants and environmental emissions were reduced 93.01% and 64.64%, respectively. Also, alone and integrated collection efficiency of cyclone and scrubber, were 94.2%, 59.05% and 97.4%, respectively. The results show good agreement with the values of the parameters ventilation system was designed. Conclusion: Implementation of integrated dust collectors is a good option in industries that have the financial and technical constraints to improve change processes and devices. This method with attainment to health and environmental standards not only can be resolve of the pollution problems, but also will be economically justified of such projects with reduction of depreciation expense and dust recycling.

  11. Association between substandard classroom ventilation rates and students' academic achievement.

    Science.gov (United States)

    Haverinen-Shaughnessy, U; Moschandreas, D J; Shaughnessy, R J

    2011-04-01

    This study focuses on the relationship between classroom ventilation rates and academic achievement. One hundred elementary schools of two school districts in the southwest United States were included in the study. Ventilation rates were estimated from fifth-grade classrooms (one per school) using CO(2) concentrations measured during occupied school days. In addition, standardized test scores and background data related to students in the classrooms studied were obtained from the districts. Of 100 classrooms, 87 had ventilation rates below recommended guidelines based on ASHRAE Standard 62 as of 2004. There is a linear association between classroom ventilation rates and students' academic achievement within the range of 0.9-7.1 l/s per person. For every unit (1 l/s per person) increase in the ventilation rate within that range, the proportion of students passing standardized test (i.e., scoring satisfactory or above) is expected to increase by 2.9% (95%CI 0.9-4.8%) for math and 2.7% (0.5-4.9%) for reading. The linear relationship observed may level off or change direction with higher ventilation rates, but given the limited number of observations, we were unable to test this hypothesis. A larger sample size is needed for estimating the effect of classroom ventilation rates higher than 7.1 l/s per person on academic achievement. The results of this study suggest that increasing the ventilation rates toward recommended guideline ventilation rates in classrooms should translate into improved academic achievement of students. More studies are needed to fully understand the relationships between ventilation rate, other indoor environmental quality parameters, and their effects on students' health and achievement. Achieving the recommended guidelines and pursuing better understanding of the underlying relationships would ultimately support both sustainable and productive school environments for students and personnel. © 2010 John Wiley & Sons A/S.

  12. Why We Ventilate

    Energy Technology Data Exchange (ETDEWEB)

    Logue, Jennifer M.; Sherman, Max H.; Price, Phil N.; Singer, Brett C.

    2011-09-01

    It is widely accepted that ventilation is critical for providing good indoor air quality (IAQ) in homes. However, the definition of"good" IAQ, and the most effective, energy efficient methods for delivering it are still matters of research and debate. This paper presents the results of work done at the Lawrence Berkeley National Lab to identify the air pollutants that drive the need for ventilation as part of a larger effort to develop a health-based ventilation standard. First, we present results of a hazard analysis that identified the pollutants that most commonly reach concentrations in homes that exceed health-based standards or guidelines for chronic or acute exposures. Second, we present results of an impact assessment that identified the air pollutants that cause the most harm to the U.S. population from chronic inhalation in residences. Lastly, we describe the implications of our findings for developing effective ventilation standards.

  13. What Is a Ventilator?

    Science.gov (United States)

    ... who are on ventilators for shorter periods. The advantage of this tube is that it can be ... other disease or condition. VAP is treated with antibiotics. You may need special antibiotics if the VAP ...

  14. Uranium mine ventilation

    International Nuclear Information System (INIS)

    Katam, K.; Sudarsono

    1982-01-01

    Uranium mine ventilation system aimed basically to control and decreasing the air radioactivity in mine caused by the radon emanating from uranium ore. The control and decreasing the air ''age'' in mine, with adding the air consumption volume, increasing the air rate consumption, closing the mine-out area; using closed drainage system. Air consumption should be 60m 3 /minute for each 9m 2 uranium ore surfaces with ventilation rate of 15m/minute. (author)

  15. Fire, safety and ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-02-01

    Correct ventilation in tunnel environments is vital for the comfort and safety of the people passing through. This article gives details of products from several manufacturers of safety rescue and fire fighting equipment, fire and fume detection equipment, special fire resistant materials, fire resistant hydraulic oils and fire dampers, and ventilation systems. Company addresses and fax numbers are supplied. 4 refs., 5 tabs., 10 photos.

  16. Integrating Dialectical Behavior Therapy and Prolonged Exposure to Treat Co-Occurring Borderline Personality Disorder and PTSD: Two Case Studies

    Science.gov (United States)

    Harned, Melanie S.; Linehan, Marsha M.

    2008-01-01

    Despite the high rate of trauma and PTSD among individuals with borderline personality disorder (BPD), no studies have specifically evaluated the treatment of PTSD in a BPD population. These case studies illustrate the use of a protocol based on prolonged exposure therapy that can be integrated into standard dialectical behavior therapy to treat…

  17. Using Images, Metaphor, and Hypnosis in Integrating Multiple Personality and Dissociative States: A Review of the Literature.

    Science.gov (United States)

    Crawford, Carrie L.

    1990-01-01

    Reviews literature on hypnosis, imagery, and metaphor as applied to the treatment and integration of those with multiple personality disorder (MPD) and dissociative states. Considers diagnostic criteria of MPD; explores current theories of etiology and treatment; and suggests specific examples of various clinical methods of treatment using…

  18. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  19. An integrative review of guidelines for anal cancer screening in HIV-infected persons.

    Science.gov (United States)

    Wells, Jessica S; Holstad, Marcia M; Thomas, Tami; Bruner, Deborah Watkins

    2014-07-01

    HIV-infected individuals are 28 times more likely than the general population to be diagnosed with anal cancer. An integrative review of recommendations and guidelines for anal cancer screening was performed to provide a succinct guide to inform healthcare clinicians. The review excluded studies that were of non-HIV populations, redundant articles or publications, non-English manuscripts, or nonclinical trials. The review found no formal national or international guidelines exist for routine screening of anal cancer for HIV-infected individuals. To date, no randomized control trial provides strong evidence supporting efficaciousness and effectiveness of an anal cancer screening program. The screening recommendations from seven international-, national-, and state-based reports were reviewed and synthesized in this review. These guidelines suggest anal cancer screening, albeit unproven, may be beneficial at decreasing the incidence of anal cancer. This review highlights the paucity of screening-related research and is an area of need to provide clear direction and to define standard of care for anal cancer screening in HIV-infected persons.

  20. Effectiveness of Integration and Re-Integration into Work Strategies for Persons with Chronic Conditions: A Systematic Review of European Strategies

    Directory of Open Access Journals (Sweden)

    Carla Sabariego

    2018-03-01

    Full Text Available Due to low employment rates associated to chronic conditions in Europe, it is essential to foster effective integration and re-integration into work strategies. The objective of this systematic review is to summarize the evidence on the effectiveness of strategies for integration and re-integration to work for persons with chronic diseases or with musculoskeletal disorders, implemented in Europe in the past five years. A systematic search was conducted in MedLine, PsycINFO, CDR-HTA, CDR-DARE and Cochrane Systematic Reviews. Overall, 32 relevant publications were identified. Of these, 21 were considered eligible after a methodological assessment and included. Positive changes in employment status, return to work and sick leave outcomes were achieved with graded sickness-absence certificates, part-time sick leave, early ergonomic interventions for back pain, disability evaluation followed by information and advice, and with multidisciplinary, coordinated and tailored return to work interventions. Additionally, a positive association between the co-existence of active labour market policies to promote employment and passive support measures (e.g., pensions or benefits and the probability of finding a job was observed. Research on the evaluation of the effectiveness of strategies targeting integration and re-integration into work for persons with chronic health conditions needs, however, to be improved and strengthened.

  1. Effectiveness of Integration and Re-Integration into Work Strategies for Persons with Chronic Conditions: A Systematic Review of European Strategies.

    Science.gov (United States)

    Sabariego, Carla; Coenen, Michaela; Ito, Elizabeth; Fheodoroff, Klemens; Scaratti, Chiara; Leonardi, Matilde; Vlachou, Anastasia; Stavroussi, Panayiota; Brecelj, Valentina; Kovačič, Dare S; Esteban, Eva

    2018-03-19

    Due to low employment rates associated to chronic conditions in Europe, it is essential to foster effective integration and re-integration into work strategies. The objective of this systematic review is to summarize the evidence on the effectiveness of strategies for integration and re-integration to work for persons with chronic diseases or with musculoskeletal disorders, implemented in Europe in the past five years. A systematic search was conducted in MedLine, PsycINFO, CDR-HTA, CDR-DARE and Cochrane Systematic Reviews. Overall, 32 relevant publications were identified. Of these, 21 were considered eligible after a methodological assessment and included. Positive changes in employment status, return to work and sick leave outcomes were achieved with graded sickness-absence certificates, part-time sick leave, early ergonomic interventions for back pain, disability evaluation followed by information and advice, and with multidisciplinary, coordinated and tailored return to work interventions. Additionally, a positive association between the co-existence of active labour market policies to promote employment and passive support measures (e.g., pensions or benefits) and the probability of finding a job was observed. Research on the evaluation of the effectiveness of strategies targeting integration and re-integration into work for persons with chronic health conditions needs, however, to be improved and strengthened.

  2. SITE TECHNOLOGY CAPSULE: SUBSURFACE VOLATILIZATION AND VENTILATION SYSTEM (SVVS)

    Science.gov (United States)

    The Subsurface Volatilization and Ventilation System is an integrated technology used for attacking all phases of volatile organic compound (VOC) contamination in soil and groundwater. The SVVS technology promotes insitu remediation of soil and groundwater contaminated with or-ga...

  3. Recommendations for mechanical ventilation of critically ill children from the Paediatric Mechanical Ventilation Consensus Conference (PEMVECC)

    NARCIS (Netherlands)

    Kneyber, Martin C. J.; de Luca, Daniele; Calderini, Edoardo; Jarreau, Pierre-Henri; Javouhey, Etienne; Lopez-Herce, Jesus; Hammer, Jurg; Macrae, Duncan; Markhorst, Dick G.; Medina, Alberto; Pons-Odena, Marti; Racca, Fabrizio; Wolf, Gerhard; Biban, Paolo; Brierley, Joe; Rimensberger, Peter C.

    2017-01-01

    Purpose: Much of the common practice in paediatric mechanical ventilation is based on personal experiences and what paediatric critical care practitioners have adopted from adult and neonatal experience. This presents a barrier to planning and interpretation of clinical trials on the use of specific

  4. Cost-benefit of ventilation and averted radon in dwellings

    International Nuclear Information System (INIS)

    Katona, T.; Kanyar, B.

    2003-01-01

    To assess an economically optimal ventilation rate we have introduced a cost-benefit analysis taking into account the cost of heating and benefit of averted dose due to ventilation. The cost of heating due to the elevated ventilation for mitigation of radon content in dwellings can be compensated by the monetary benefit of the averted dose, in case of higher (annually 3-10 mSv) exposure. During the heating season the economically optimal ventilation takes 0.1-0.5 h -1 , meanwhile the radon concentration in the indoor air decreases to 200-800 Bq/m 3 , depending on the exhalation of radon, number of persons living in the dwellings and other local parameters. Our results from the optimal planning correspond to the radon concentrations recommended by the international organizations as action levels. In general, the periodic ventilation in daytime provides a higher averted dose than the constant one in case of the same heating cost. (authors)

  5. Personality characteristics of children in an orphanage as criteria for the developing of proactive attitude and successful social integration

    Directory of Open Access Journals (Sweden)

    Larin A.N.

    2016-06-01

    Full Text Available The article presents the results of a personality characteristics study of orphans and children left without parental care growing up in an orphanage. It is assumed that examined personality characteristics have an effect on the socialization and integration processes after graduating from the orphanage. The paper gives a comparative analysis of personality characteristics in 18 boys and 14 girls aged from 12 to 17 years in orphanages, as well as finds out the personality characteristics undermining the developing of child’s proactive attitude. The study used a children's version of "Individual typological questionnaire" by L.N. Sobchik and Cattell 14 PF method of multivariate personality study. Statistical significance of the results is due to Mann–Whitney U test and Student t-test for nonrandom access. Cattell 14PF study shows that boys and girls in the test groups have personality differences (p≤0.05. A pattern of the results may indicate a general trend of personal characteristics negatively affecting the success of adaptation after graduating from the orphanage.

  6. Demand Controlled Ventilation in a Combined Ventilation and Radiator System

    OpenAIRE

    Hesaraki, Arefeh; Holmberg, Sture

    2013-01-01

    With growing concerns for efficient and sustainable energy treatment in buildings there is a need for balanced and intelligent ventilation solutions. This paper presents a strategy for demand controlled ventilation with ventilation radiators, a combined heating and ventilation system. The ventilation rate was decreased from normal requirements (per floor area) of 0.375 l·s-1·m-2 to 0.100 l·s-1·m-2 when the residence building was un-occupied. The energy saving potential due to decreased ventil...

  7. Recommended Ventilation Strategies for Energy-Efficient Production Homes

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, J.; Brown, R.; Koomey, J.; Warner, J.; Greenberg, S.

    1998-12-01

    This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR{reg_sign} Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis Department at Lawrence Berkeley National Lab compared residential ventilation strategies in four climates according to three criteria: total annualized costs (the sum of annualized capital cost and annual operating cost), predominant indoor pressure induced by the ventilation system, and distribution of ventilation air within the home. The mechanical ventilation systems modeled deliver 0.35 air changes per hour continuously, regardless of actual infiltration or occupant window-opening behavior. Based on the assumptions and analysis described in this report, we recommend independently ducted multi-port supply ventilation in all climates except cold because this strategy provides the safety and health benefits of positive indoor pressure as well as the ability to dehumidify and filter ventilation air. In cold climates, we recommend that multi-port supply ventilation be balanced by a single-port exhaust ventilation fan, and that builders offer balanced heat-recovery ventilation to buyers as an optional upgrade. For builders who continue to install forced-air integrated supply ventilation, we recommend ensuring ducts are airtight or in conditioned space, installing a control that automatically operates the forced-air fan 15-20 minutes during each hour that the fan does not operate for heating or cooling, and offering ICM forced-air fans to home buyers as an upgrade.

  8. Personal Control Over Heating, Cooling and Ventilation

    DEFF Research Database (Denmark)

    Boerstra, Atze; Simone, Angela

    2013-01-01

    This article presents a summary of a Workshop at 11th Clima Wolrd Conference 2013 in Prague. The workshop was organised by REHVA in cooperation with ISIAQ (International Society of Indoor Air Quality and Climate), and chaired by Atze Boerstra and Angela Simone.......This article presents a summary of a Workshop at 11th Clima Wolrd Conference 2013 in Prague. The workshop was organised by REHVA in cooperation with ISIAQ (International Society of Indoor Air Quality and Climate), and chaired by Atze Boerstra and Angela Simone....

  9. Clinical challenges in mechanical ventilation.

    Science.gov (United States)

    Goligher, Ewan C; Ferguson, Niall D; Brochard, Laurent J

    2016-04-30

    Mechanical ventilation supports gas exchange and alleviates the work of breathing when the respiratory muscles are overwhelmed by an acute pulmonary or systemic insult. Although mechanical ventilation is not generally considered a treatment for acute respiratory failure per se, ventilator management warrants close attention because inappropriate ventilation can result in injury to the lungs or respiratory muscles and worsen morbidity and mortality. Key clinical challenges include averting intubation in patients with respiratory failure with non-invasive techniques for respiratory support; delivering lung-protective ventilation to prevent ventilator-induced lung injury; maintaining adequate gas exchange in severely hypoxaemic patients; avoiding the development of ventilator-induced diaphragm dysfunction; and diagnosing and treating the many pathophysiological mechanisms that impair liberation from mechanical ventilation. Personalisation of mechanical ventilation based on individual physiological characteristics and responses to therapy can further improve outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. OmniPHR: A distributed architecture model to integrate personal health records.

    Science.gov (United States)

    Roehrs, Alex; da Costa, Cristiano André; da Rosa Righi, Rodrigo

    2017-07-01

    The advances in the Information and Communications Technology (ICT) brought many benefits to the healthcare area, specially to digital storage of patients' health records. However, it is still a challenge to have a unified viewpoint of patients' health history, because typically health data is scattered among different health organizations. Furthermore, there are several standards for these records, some of them open and others proprietary. Usually health records are stored in databases within health organizations and rarely have external access. This situation applies mainly to cases where patients' data are maintained by healthcare providers, known as EHRs (Electronic Health Records). In case of PHRs (Personal Health Records), in which patients by definition can manage their health records, they usually have no control over their data stored in healthcare providers' databases. Thereby, we envision two main challenges regarding PHR context: first, how patients could have a unified view of their scattered health records, and second, how healthcare providers can access up-to-date data regarding their patients, even though changes occurred elsewhere. For addressing these issues, this work proposes a model named OmniPHR, a distributed model to integrate PHRs, for patients and healthcare providers use. The scientific contribution is to propose an architecture model to support a distributed PHR, where patients can maintain their health history in an unified viewpoint, from any device anywhere. Likewise, for healthcare providers, the possibility of having their patients data interconnected among health organizations. The evaluation demonstrates the feasibility of the model in maintaining health records distributed in an architecture model that promotes a unified view of PHR with elasticity and scalability of the solution. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Integrating sequencing technologies in personal genomics: optimal low cost reconstruction of structural variants.

    Directory of Open Access Journals (Sweden)

    Jiang Du

    2009-07-01

    Full Text Available The goal of human genome re-sequencing is obtaining an accurate assembly of an individual's genome. Recently, there has been great excitement in the development of many technologies for this (e.g. medium and short read sequencing from companies such as 454 and SOLiD, and high-density oligo-arrays from Affymetrix and NimbelGen, with even more expected to appear. The costs and sensitivities of these technologies differ considerably from each other. As an important goal of personal genomics is to reduce the cost of re-sequencing to an affordable point, it is worthwhile to consider optimally integrating technologies. Here, we build a simulation toolbox that will help us optimally combine different technologies for genome re-sequencing, especially in reconstructing large structural variants (SVs. SV reconstruction is considered the most challenging step in human genome re-sequencing. (It is sometimes even harder than de novo assembly of small genomes because of the duplications and repetitive sequences in the human genome. To this end, we formulate canonical problems that are representative of issues in reconstruction and are of small enough scale to be computationally tractable and simulatable. Using semi-realistic simulations, we show how we can combine different technologies to optimally solve the assembly at low cost. With mapability maps, our simulations efficiently handle the inhomogeneous repeat-containing structure of the human genome and the computational complexity of practical assembly algorithms. They quantitatively show how combining different read lengths is more cost-effective than using one length, how an optimal mixed sequencing strategy for reconstructing large novel SVs usually also gives accurate detection of SNPs/indels, how paired-end reads can improve reconstruction efficiency, and how adding in arrays is more efficient than just sequencing for disentangling some complex SVs. Our strategy should facilitate the sequencing of

  12. The access of the homeless persons with tuberculosis to the health care: an integrative review

    Directory of Open Access Journals (Sweden)

    Annelissa Andrade Virgínio de Oliveira

    2017-04-01

    Full Text Available Introduction: The Tuberculosis (TB keeps being a big public health problem in the world, having the poverty, the bad life condition, the bad income distribution, the social iniquity and the disability on the health system as a substrate to its maintenance. Objective: To identify the scientific knowledge produced under the access to the health service of the homeless person sick by TB. Method: Integrative literature review conducted from April to June, 2016, having as inclusion criteria: publications written in Portuguese, English or Spanish, published from 1990 to 2015, indexed on the data basis: LILACS, SciELO, MEDLINE and Web of Science and portals Virtual Health Library (VHL and MEDLINE/PubMed, that had the text completely available online. As searching strategy was used the Boolean operator AND, with the descriptors: Tuberculosis, health services accessibility; homeless persons. To obtain the information that answered the research guideline question was elaborated a form that contemplated the following items: identification, theme, descriptors or key-words, abstract, introduction, method, results, discussion, conclusions and references. The search resulted in 51 articles that, observed with the inclusion and exclusion criteria, resulted in 10 complete articles. The data analyzes was made in qualitative terms, summarized in three categories: I Specific characteristics of the homeless people access to the health services to tuberculosis diagnostic and treatment; II Access difficulty to the health care: factors related to homeless people and factors related to health services; III Strategies to overcome the access difficulties of the homeless person (HLP  to the health care. Results: pointed that the homeless people have a higher risk to get sick by TB, presenting TB incidence rate 10 to 20 times higher than the general population. Many obstacles that limited those people access to the health services were identified. Many times they presented

  13. An HVAC [heating, ventilation, and air-conditioning] fault-tree analysis for WIPP [Waste Isolation Pilot Plant] integrated risk assessment

    International Nuclear Information System (INIS)

    Kirby, P.N.; Iacovino, J.M.

    1990-01-01

    In order to evaluate the public health risk of potential radioactive releases from operation of the Waste Isolation Pilot Plant (WIPP), a probabilistic risk assessment of waste-handling operations was conducted. One major aspect of this risk assessment involved fault-tree analysis of the plant heating, ventilation, and air-conditioning (HVAC) systems, which constitute the final barrier between waste-handling operations and the environment. The WIPP site is designed to receive and store two types of waste: contact-handled transuranic (CH TRU) wastes to be shipped in 208-ell drums and remote-handled (RH) TRU wastes to be shipped in shielded casks. The identification of accident sequences for CH waste operations revealed no identified accidents that could release significant radioactive particulates to the environment without a failure in the HVAC systems. When the HVAC fault-tree results were combined with other critical system fault trees and the analysis of waste-handling accident sequences, the approximation of the overall WIPP plant risk due to airborne releases was determined to be 2.6 x 10 -7 fatalities per year for the population within a 50-mile radius of the WIPP site. This risk was demonstrated to be well below the risk of fatality from other voluntary and involuntary activities for the population within the vicinity of the WIPP

  14. A Test of an Integrative Model Using Social Factors and Personality Traits: Prediction on the Delinquency of South Korean Youth.

    Science.gov (United States)

    Yun, Minwoo; Kim, Eunyoung; Park, Woong-Sub

    2017-08-01

    To more fully comprehend juvenile delinquency, it is necessary to take an integrative approach, with consideration of both personality traits of social risk factors. Many scholars argue the necessity and strength of integrative approach on the ground that juvenile delinquency is an outcome of interplay of individual and social factors. The present study examines the general applicability of an integrative model of personal traits and social risk factors to youth delinquency in the South Korean context. The empirical results show that the delinquency predictors in the current South Korean sample are closely aligned to Loeber and Farrington's theoretical propositions and that found in Western nations. Perhaps this is because South Korea has undergone rapid Westernization for the last decades. Because the correlates in this sample and Western theoretical propositions and studies overlap, an integrative model of personality trait and social risk factors is indeed generally applicable to South Korea. This finding also depicts the extent of Westernization in the South Korean society at least among adolescents. Limitations of the present study and directions for the future study are discussed.

  15. Ventilation of radioactive enclosures

    International Nuclear Information System (INIS)

    Caminade, F.; Laurent, H.

    1957-01-01

    Mechanical, physical and chemical manipulations on radioactive products must be carried out in properly ventilated enclosed places. The air extracted can only be discharged into the atmosphere after a correct filtration. The power of the ventilation systems is a function of the dimensions and purpose of the enclosure? The choice of types of filter is determined by the physical state and chemical nature of the radioactive materials to be manipulated. This study deals with the individual equipment of small installations: glove boxes, manipulation boxes with outside control and, if necessary, production chambers (maximum useful volume: 5 m 3 ). The performances of three types of 'ventilators', and the modifications provided by the addition of filters, are measured and compared. (author) [fr

  16. Mechanical ventilation strategies.

    Science.gov (United States)

    Keszler, Martin

    2017-08-01

    Although only a small proportion of full term and late preterm infants require invasive respiratory support, they are not immune from ventilator-associated lung injury. The process of lung damage from mechanical ventilation is multifactorial and cannot be linked to any single variable. Atelectrauma and volutrauma have been identified as the most important and potentially preventable elements of lung injury. Respiratory support strategies for full term and late preterm infants have not been as thoroughly studied as those for preterm infants; consequently, a strong evidence base on which to make recommendations is lacking. The choice of modalities of support and ventilation strategies should be guided by the specific underlying pathophysiologic considerations and the ventilatory approach must be individualized for each patient based on the predominant pathophysiology at the time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Ventilator associated pneumonia].

    Science.gov (United States)

    Bellani, S; Nesci, M; Celotto, S; Lampati, L; Lucchini, A

    2003-04-01

    Ventilator associated pneumonia (VAP) is a nosocomial lower respiratory tract infection that ensues in critically ill patients undergoing mechanical ventilation. The reported incidence of VAP varies between 9% and 68% with a mortality ranging between 33% and 71%. Two key factors are implicated in the pathogenesis of VAP: bacterial colonization of the upper digestive-respiratory tract and aspiration of oral secretions into the trachea. Preventive measurements are advocated to reduce the incidence of VAP, such as selective decontamination of the digestive tract (SDD), supraglottic aspiration and positioning. Prompt recognition and treatment of established VAP has also been demostrated to affect outcome. Therefore, the knowledge of risk factors associated with the development of VAP and the implementation of strategies to prevent, diagnose and treat VAP are mainstems in the nursing of mechanically ventilated patients.

  18. Auxiliary mine ventilation manual

    International Nuclear Information System (INIS)

    Workplace Safety North

    2010-01-01

    An adequate ventilation system is needed for air quality and handling in a mine and is comprised of many different pieces of equipment for removing contaminated air and supplying fresh air and thereby provide a satisfactory working environment. This manual highlights auxiliary ventilation systems made up of small fans, ducts, tubes, air movers, deflectors and additional air flow controls which distribute fresh air delivered by the primary system to all areas. A review of auxiliary ventilation is provided. Design, operation and management issues are discussed and guidelines are furnished. This manual is limited to underground hard rock operations and does not address directly other, specific auxiliary systems, either in underground coal mines or uranium mines.

  19. Auxiliary mine ventilation manual

    Energy Technology Data Exchange (ETDEWEB)

    Workplace Safety North

    2010-07-01

    An adequate ventilation system is needed for air quality and handling in a mine and is comprised of many different pieces of equipment for removing contaminated air and supplying fresh air and thereby provide a satisfactory working environment. This manual highlights auxiliary ventilation systems made up of small fans, ducts, tubes, air movers, deflectors and additional air flow controls which distribute fresh air delivered by the primary system to all areas. A review of auxiliary ventilation is provided. Design, operation and management issues are discussed and guidelines are furnished. This manual is limited to underground hard rock operations and does not address directly other, specific auxiliary systems, either in underground coal mines or uranium mines.

  20. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  1. Behovstyret ventilation til enfamiliehuse

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Drivsholm, Christian; Hansen, Mads Peter Rudolph

    Muligheden for behovsstyret ventilation i enfamiliehuse er undersøgt. To strategier er afprøvet i praksis: En relativ simpel og billig strategi og en relativ avanceret og dyr strategi. Den simple strategi regulerer luftskiftet ensartet for alle rum mellem et lavt eller højt niveau. Den avancerede...... ventilation efter gældende krav. Desuden kræver den simple regulering kun få sensorer og er således væsentlig billigere og enklere at implementere end den avancerede strategi....

  2. Bench performance of ventilators during simulated paediatric ventilation.

    Science.gov (United States)

    Park, M A J; Freebairn, R C; Gomersall, C D

    2013-05-01

    This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.

  3. A Non-Ventilated Solar Façade Concept Based on Selective and Transparent Insulation Material Integration: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Miroslav Čekon

    2017-06-01

    Full Text Available A new solar façade concept based on transparent insulation and a selective absorber is proposed, tested and compared with conventional insulation and a non-selective type of absorber, respectively. The presented study focuses on an experimental non-ventilated solar type of façade exposed to solar radiation both in the laboratory and in outdoor tests. Due to the high solar absorbance level of the façade, high- and low-emissivity contributions were primarily analysed. All of the implemented materials were contrasted from the thermal and optical point of view. An analysis was made of both thermodynamic and steady state procedures affecting the proposed solar façade concept. Experimental full scale tests on real building components were additionally involved during summer monitoring. An indicator of the temperature response generated by solar radiation exposure demonstrates the outdoor performance of the façade is closely related to overheating phenomena. From the thermal point of view, the proposed transparent insulation and selective absorber concept corresponds to the performance of conventional thermal insulation of identical material thickness; however, the non-selective prototype only provides 50% thermal performance. The results of the solar-based experiments show that with a small-scale experimental prototype, approximately no significant difference is measured when compared with a non-selective absorber type. The only difference was achieved at the maximum of 2.5 K, when the lower temperature was obtained in the solar selective concept. At the full-scale outdoor mode, the results indicate a maximum of 3.0 K difference, however the lower temperature achieves a non-selective approach. This solar façade can actively contribute to the thermal performance of building components during periods of heating.

  4. Motivations, Values, and Conflict Resolution: Students' Integration of Personal and Professional Identities

    Science.gov (United States)

    Osteen, Philip J.

    2011-01-01

    Edicts within the Council on Social Work Education's 2008 Educational Policy and Accreditation Standards address the importance of understanding the intersection of personal and professional values. Twenty MSW students, chosen on the basis of diverse cultural and personal characteristics, were interviewed about their motivations for pursuing a MSW…

  5. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  6. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Walker, Iain; Sherman, Max

    2011-01-01

    Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as "dose") as the metric to evaluate the effectiveness and air quality...... implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant...... when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we...

  7. Demand controlled ventilation; Behovsstyrt ventilasjon

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Henning Holm

    2006-07-01

    The terms CAV and VAV have been known terms for many years in the ventilation business. The terms are also included in building regulations, but the time is now right to focus on demand controlled ventilation (DCV). The new building regulations and the accompanying energy framework underline the need for a more nuanced thinking when it comes to controlling ventilation systems. Descriptions and further details of the ventilation systems are provided (ml)

  8. Development of an integrated model of personality, personality disorders and severe axis I disorders, with special reference to major affective disorders.

    Science.gov (United States)

    von Zerssen, Detlev

    2002-04-01

    A unidimensional model of the relationships between normal temperament, psychopathic variants of it and the two main forms of so-called endogenous psychoses (major affective disorders and schizophrenia) was derived from Kretschmer's constitutional typology. It was, however, not confirmed by means of a biometric approach nor was Kretschmer's broad concept of cyclothymia as a correlate of physical stoutness on the one hand and major affective disorders on the other supported by empirical data. Yet the concept of the 'melancholic type' of personality of patients with severe unipolar major depression (melancholia) which resembles descriptions by psychoanalysts could be corroborated. This was also true for the 'manic type' of personality as a (premorbid) correlate of predominantly manic forms of a bipolar I disorder. As predicted from a spectrum concept of major affective disorders, the ratio of traits of either type co-varied with the ratio of the depressive and the manic components in the long-term course of such a disorder. The two types of premorbid personality and a rare variant of the 'manic type', named 'relaxed, easy-going type', were conceived as 'affective types' dominating in major affective disorders. They are opposed to three 'neurotoid types' prevailing in so-called neurotic disorders as well as in schizophrenic psychoses. The similarity among the types can be visualized as spatial relationships in a circular, i.e. a two-dimensional, model (circumplex). Personality disorders as maladapted extreme variants of personality are, by definition, located outside the circle, mainly along its 'neurotoid' side. However, due to their transitional nature, axis I disorders cannot be represented adequately within the plane which represents (adapted as well as maladapted) forms of habitual behaviour (personality types and disorders, respectively). To integrate them into the spatial model of similarity interrelations, a dimension of actual psychopathology has to be added

  9. Battery life of portable home ventilators: effects of ventilator settings.

    Science.gov (United States)

    Falaize, Line; Leroux, Karl; Prigent, Hélène; Louis, Bruno; Khirani, Sonia; Orlikowski, David; Fauroux, Brigitte; Lofaso, Frédéric

    2014-07-01

    The battery life (BL) of portable home ventilator batteries is reported by manufacturers. The aim of this study was to evaluate the effects of ventilator mode, breathing frequency, PEEP, and leaks on the BL of 5 commercially available portable ventilators. The effects of the ventilator mode (volume controlled-continuous mandatory ventilation [VC-CMV] vs pressure support ventilation [PSV]), PEEP 5 cm H2O, breathing frequency (10, 15, and 20 breaths/min), and leaks during both volume-targeted ventilation and PSV on the BL of 5 ventilators (Elisée 150, Monnal T50, PB560, Vivo 50, and Trilogy 100) were evaluated. Each ventilator was ventilated with a test lung at a tidal volume of 700 ml and an inspiratory time of 1.2 s in the absence of leaks. Switching from PSV to VC-CMV or the addition of PEEP did not significantly change ventilator BL. The increase in breathing frequency from 10 to 20 breaths/min decreased the BL by 18 ± 11% (P = .005). Leaks were associated with an increase in BL during the VC-CMV mode (18 ± 20%, P = .04) but a decrease in BL during the PSV mode (-13 ± 15%, P = .04). The BL of home ventilators depends on the ventilator settings. BL is not affected by the ventilator mode (VC-CMV or PSV) or the addition of PEEP. BL decreases with an increase in breathing frequency and during leaks with a PSV mode, whereas leaks increase the duration of ventilator BL during VC-CMV. Copyright © 2014 by Daedalus Enterprises.

  10. Hybrid Ventilation Air Flow Process

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols

    The scope of this annex is therefore to obtain better knowledge of the use of hybrid ventilation technologies. The annex focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on implementation...

  11. Ventilator and viral induced inflammation

    NARCIS (Netherlands)

    Hennus, M.P.

    2013-01-01

    This thesis expands current knowledge on ventilator induced lung injury and provides insights on the immunological effects of mechanical ventilation during viral respiratory infections. The experimental studies in the first part of this thesis improve our understanding of how mechanical ventilation

  12. How to Plan Ventilation Systems.

    Science.gov (United States)

    Clarke, John H.

    1963-01-01

    Ventilation systems for factory safety demand careful planning. The increased heat loads and new processes of industry have introduced complex ventilation problems in--(1) ventilation supply, (2) duct work design, (3) space requirements, (4) hood face velocities, (5) discharge stacks, and (6) building eddies. This article describes and diagrams…

  13. Thermal Plumes in Ventilated Rooms

    DEFF Research Database (Denmark)

    Kofoed, P.; Nielsen, Peter Vilhelm

    The main objective of ventilation is to provide good air quality for the occupants. For this purpose the necessary ventilating air change rate must be determined. Within displacement ventilation the estimation is closely related to the air flow rate in the thermal plumes when an air quality based...

  14. The amazing Minivent ventilator

    African Journals Online (AJOL)

    Southern African Journal of Anaesthesia and Analgesia is co-published by Medpharm Publications, NISC (Pty) Ltd and Cogent, ... Respiratory rate was obtained by counting the clicking noise ... was appointed as a part-time lecturer to the University of the ... The Minivent became the first of three miniature ventilators that.

  15. Omnidirectional ventilated acoustic barrier

    Science.gov (United States)

    Zhang, Hai-long; Zhu, Yi-fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-chun

    2017-11-01

    As an important problem in acoustics, sound insulation finds applications in a great variety of situations. In the existing schemes, however, there has always been a trade-off between the thinness of sound-insulating devices and their ventilating capabilities, limiting their potentials in the control of low-frequency sound in high ventilation environments. Here, we design and experimentally implement an omnidirectional acoustic barrier with a planar profile, subwavelength thickness ( 0.18 λ ), yet high ventilation. The proposed mechanism is based on the interference between the resonant scattering of discrete states and the background scattering of continuous states which induces a Fano-like asymmetric transmission profile. Benefitting from the binary-structured design of the coiled unit and hollow pipe, it maximally simplifies the design and fabrication while ensuring the ventilation for all the non-resonant units with open tubes. The simulated and measured results agree well, showing the effectiveness of our proposed mechanism to block low frequency sound coming from various directions while allowing 63% of the air flow to pass. We anticipate our design to open routes to design sound insulators and to enable applications in traditionally unattainable cases such as those calling for noise reduction and cooling simultaneously.

  16. Mechanical ventilation of mice

    NARCIS (Netherlands)

    Schwarte, L. A.; Zuurbier, C. J.; Ince, C.

    2000-01-01

    Due to growing interest in murine functional genomics research, there is an increasing need for physiological stable in vivo murine models. Of special importance is support and control of ventilation by artificial respiration, which is difficult to execute as a consequence of the small size of the

  17. Lavt elforbrug til ventilation

    DEFF Research Database (Denmark)

    Jagemar, L.; Bergsøe, Niels Christian

    Rapporten giver gode råd om mulige energibesparelser og praktiske projekteringshensyn, som er forbundet med udformning af energieffektiv ventilation i ikke blot kontorbygninger, men i alle bygninger med komfortventilationsanlæg. I forbindelse med projektering af ventilationsanlæg har interessen...

  18. Understanding mechanical ventilators.

    Science.gov (United States)

    Chatburn, Robert L

    2010-12-01

    The respiratory care academic community has not yet adopted a standardized system for classifying and describing modes of ventilation. As a result, there is enough confusion that patient care, clinician education and even ventilator sales are all put at risk. This article summarizes a ventilator mode taxonomy that has been extensively published over the last 15 years. Specifically, the classification system has three components: a description of the control variables within breath; a description of the sequence of mandatory and spontaneous breaths; and a specification for the targeting scheme. This three-level specification provides scalability of detail to make the mode description appropriate for the particular need. At the bedside, we need only refer to a mode briefly using the first or perhaps first and second components. To distinguish between similar modes and brand names, we would need to include all components. This taxonomy uses the equation of motion for the respiratory system as the underlying theoretical framework. All terms relevant to describing modes of mechanical ventilation are defined in an extensive appendix.

  19. Chord Label Personalization through Deep Learning of Integrated Harmonic Interval-based Representations

    NARCIS (Netherlands)

    Koops, H. V.; Haas, W. B. de; Bransen, J.; Volk, A.

    2017-01-01

    The increasing accuracy of automatic chord estimation systems, the availability of vast amounts of heterogeneous reference annotations, and insights from annotator subjectivity research make chord label personalization increasingly important. Nevertheless, automatic chord estimation systems are

  20. Career transitions for persons with severe physical disabilities: integrating technological and psychosocial skills and accommodations.

    Science.gov (United States)

    Lash, M; Licenziato, V

    1995-01-01

    This article describes a vocational training program entitled, 'Careers in Automation for Persons with Severe Physical Disabilities', that was developed by the Department of Physical Medicine and Rehabilitation at Tufts University School of Medicine in collaboration with the Massachusetts Rehabilitation Commission. Its goal is to secure employment for individuals with severe physical impairments by using computers and technology as job related accommodations. Psychosocial, educational, and vocational profiles are presented for 24 clients over 4 years. Three case studies involving persons with traumatic, chronic and developmental disabilities illustrate the importance of matching technological accommodations with employer needs and personal preferences. Discussion of employment outcomes illustrates that the effective use of computers and technology by persons with disabilities is best measured not by the degree of sophistication and engineering of systems and devices, but by employer and employee satisfaction with job performance and productivity.

  1. Reframing Catholic Ethics: Is the Person an Integral and Adequate Starting Point?

    Directory of Open Access Journals (Sweden)

    Lisa Sowle Cahill

    2017-10-01

    Full Text Available Joseph Selling rightly defines human intentions and motivations as part of human nature and an important determinant of the morality of personal actions. The thesis of this paper is that Selling’s view of agency, as focused on the individual, must be expanded to include social relationships and the social constitution of selves and communities. This requires cross-cultural dialogue about human nature, the goods for persons and societies, and social ethics.

  2. A novel personal health system with integrated decision support and guidance for the management of chronic liver disease.

    Science.gov (United States)

    Kiefer, Stephan; Schäfer, Michael; Bransch, Marco; Brimmers, Peter; Bartolomé, Diego; Baños, Janie; Orr, James; Jones, Dave; Jara, Maximilian; Stockmann, Martin

    2014-01-01

    A personal health system platform for the management of patients with chronic liver disease that incorporates a novel approach to integrate decision support and guidance through care pathways for patients and their doctors is presented in this paper. The personal health system incorporates an integrated decision support engine that guides patients and doctors through the management of the disease by issuing tasks and providing recommendations to both the care team and the patient and by controlling the execution of a Care Flow Plan based on the results of tasks and the monitored health status of the patient. This Care Flow Plan represents a formal, business process based model of disease management designed off-line by domain experts on the basis of clinical guidelines, knowledge of care pathways and an organisational model for integrated, patient-centred care. In this way, remote monitoring and treatment are dynamically adapted to the patient's actual condition and clinical symptoms and allow flexible delivery of care with close integration of specialists, therapists and care-givers.

  3. Understanding the experience of place: expanding methods to conceptualize and measure community integration of persons with serious mental illness.

    Science.gov (United States)

    Townley, Greg; Kloos, Bret; Wright, Patricia A

    2009-06-01

    Community integration research explores community contexts and factors that encourage or hinder individuals with serious mental illness (SMI) from actively participating in community life. This research agenda can be advanced by using mixed-methods that better document the relationships between contextual factors and individual experience. Two such methods were applied to a mixed-methods study of 40 adults with SMI living in independent housing in the Southeastern United States. Their contextualized experiences of community integration were measured by applying innovative participatory mapping and Geographic Information Systems (GIS) mapping techniques. Use of these methods in conjunction with one another facilitated the creation of activity spaces, which can measure geographic accessibility and help to represent an individual's experience of place and degree of mobility. The utility of these newly applied methods for better understanding community integration for persons with SMI is explored and implications for using these measures in research and practice are discussed.

  4. Ventilation of nuclear power plants

    International Nuclear Information System (INIS)

    Madoyan, A.A.; Vlasik, V.F.

    1984-01-01

    Foundations and calculation methods of ventilation of rooms with different degree of heat and gas release with the change of operation mode of NPP main equipment, as well as problems of NPP site and adjoining area aerodynamics, have been presented. Systems of air ventilation and conditioning, cooling equipment, are considered. The main points of designing are described and determination of economic efficiency of the ventilation systems are made. Technical characteristics of the ventilators, conditioners, filters and air heaters used, are presented. Organization of adjustment, tests, operation and maintenance of the ventilation systems of NPP with RBMK and WWER-type reactors, is described

  5. Personalized Medicine: how to Switch from the Concept to the Integration into the Clinical Development Plan to Obtain Marketing Authorization.

    Science.gov (United States)

    Becquemont, Laurent; Bordet, Régis; Cellier, Dominic

    2012-01-01

    One of the challenges of the coming years is to personalize medicine in order to provide each patient with an individualized treatment plan. The three objectives of personalized medicine are to refine diagnosis, rationalize treatment and engage patients in a preventive approach. Personalization can be characterized by various descriptors whether related to the field, biology, imaging, type of lesion of the entity to be treated, comorbidity factors, coprescriptions or the environment As part of personalized medicine focused on biological markers including genetics or genomics, the integration of the clinical development plan to obtain marketing authorization may be segmented in 3 stages with a known descriptor identified before clinical development, a known descriptor discovered during clinical development or a known descriptor known after clinical development. For each stage, it is important to clearly define the technical optimization elements, to specify the expectations and objectives, to examine the methodological aspects of each clinical development phase and finally to consider the fast changing regulatory requirements in view of the few registered therapeutics complying with the definition of personalized medicine as well as the significant technological breakthroughs according to the screened and selected biomarkers. These considerations should be integrated in view of the time required for clinical development from early phase to MA, i.e. more than 10 years. Moreover, business models related to the economic environment should be taken into account when deciding whether or not to retain a biomarker allowing the selection of target populations in a general population. © 2012 Société Française de Pharmacologie et de Thérapeutique.

  6. La formación integral en Dios como fundamento del desarrollo personal y social

    OpenAIRE

    Flórez Luna, Carlos Alberto

    2015-01-01

    Este texto pretende mostrar la importancia de una formación integral basada en principios morales y espirituales que orienten al individuo hacia el desarrollo armonioso del ser, teniendo en cuenta las diferentes dimensiones del ser humano. Por lo tanto, se abordan de manera directa el concepto de formación integral y sus implicaciones en el contexto social.

  7. An integrative examination of general personality dysfunction in a large community sample.

    Science.gov (United States)

    Hengartner, Michael Pascal; De Fruyt, Filip; Rodgers, Stephanie; Müller, Mario; Rössler, Wulf; Ajdacic-Gross, Vladeta

    2014-10-01

    Recently, the severity of general personality dysfunction has gained broad interest in personality disorder (PD) research. We analysed data of 511 participants aged 20-41 years from a comprehensive psychiatric survey in the general population of Zurich, Switzerland. We added the trait-scores from all DSM-IV PDs, as assessed by a self-report questionnaire, to provide a measure of general personality dysfunction. Adjusting for the Big Five personality domains as a proxy for stylistic PD elements, this composite PD score exhibited strong associations with neuroticism and schizotypy. General personality dysfunction additionally revealed a moderate detrimental association with psychosocial functioning and a strong effect on coping resources, on heavy drinking and drug use and on most psychopathological syndromes. Of particular interest is the strong association with total psychopathological distress and co-occurrence of multiple disorders, suggesting that increasing PD severity relates to the degree of global impairment independent of specific PD traits. Discussed herein are implications for public mental health policies, classification, conceptualization and treatment of PDs. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Personality, foraging behavior and specialization: integrating behavioral and food web ecology at the individual level.

    Science.gov (United States)

    Toscano, Benjamin J; Gownaris, Natasha J; Heerhartz, Sarah M; Monaco, Cristián J

    2016-09-01

    Behavioral traits and diet were traditionally thought to be highly plastic within individuals. This view was espoused in the widespread use of optimality models, which broadly predict that individuals can modify behavioral traits and diet across ecological contexts to maximize fitness. Yet, research conducted over the past 15 years supports an alternative view; fundamental behavioral traits (e.g., activity level, exploration, sociability, boldness and aggressiveness) and diet often vary among individuals and this variation persists over time and across contexts. This phenomenon has been termed animal personality with regard to behavioral traits and individual specialization with regard to diet. While these aspects of individual-level phenotypic variation have been thus far studied in isolation, emerging evidence suggests that personality and individual specialization may covary, or even be causally related. Building on this work, we present the overarching hypothesis that animal personality can drive specialization through individual differences in various aspects of consumer foraging behavior. Specifically, we suggest pathways by which consumer personality traits influence foraging activity, risk-dependent foraging, roles in social foraging groups, spatial aspects of foraging and physiological drivers of foraging, which in turn can lead to consistent individual differences in food resource use. These pathways provide a basis for generating testable hypotheses directly linking animal personality to ecological dynamics, a major goal in contemporary behavioral ecology.

  9. Culture, personality, and subjective well-being: integrating process models of life satisfaction.

    Science.gov (United States)

    Schimmack, Ulrich; Radhakrishnan, Phanikiran; Oishi, Shigehiro; Dzokoto, Vivian; Ahadi, Stephan

    2002-04-01

    The authors examined the interplay of personality and cultural factors in the prediction of the affective (hedonic balance) and the cognitive (life satisfaction) components of subjective well-being (SWB). They predicted that the influence of personality on life satisfaction is mediated by hedonic balance and that the relation between hedonic balance and life satisfaction is moderated by culture. As a consequence, they predicted that the influence of personality on life satisfaction is also moderated by culture. Participants from 2 individualistic cultures (United States, Germany) and 3 collectivistic cultures (Japan, Mexico, Ghana) completed measures of Extraversion, Neuroticism, hedonic balance, and life satisfaction. As predicted, Extraversion and Neuroticism influenced hedonic balance to the same degree in all cultures, and hedonic balance was a stronger predictor of life satisfaction in individualistic than in collectivistic cultures. The influence of Extraversion and Neuroticism on life satisfaction was largely mediated by hedonic balance. The results suggest that the influence of personality on the emotional component of SWB is pancultural, whereas the influence of personality on the cognitive component of SWB is moderated by culture.

  10. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  11. Nursing Students' Attitudes Toward Lesbian, Gay, Bisexual, and Transgender Persons: An Integrative Review.

    Science.gov (United States)

    Lim, Fidelindo A; Hsu, Richard

    2016-01-01

    The aim of this study was to critically appraise and synthesize findings from studies on the attitudes of nursing students toward lesbian, gay, bisexual, and transgender (LGBT) persons. There is paucity of research to assess the attitudes of nursing students toward LGBT persons. An electronic search was conducted using PubMed, Medline, Web of Science, EbscoHost, PsycInfo, and the Cumulative Index to Nursing and Allied Health Literature using medical subject headings terminologies. Search terms used included gay, lesbian, transgender, bisexual, LGBT, nursing students, baccalaureate nursing, undergraduate nursing, homophobia, homosexuality, sexual minority, attitudes, discrimination, and prejudice. Less than 50 percent of the studies (5 out of 12) suggested positively leaning attitudes of nursing students toward LGBT persons; six studies reported negative attitudes, and one study reported neutral attitudes. There are some indications that student attitudes may be moving toward positively leaning. Studies published before 2000 reported a preponderance of negative attitudes.

  12. High Frequency Oscillatory Ventilation

    Directory of Open Access Journals (Sweden)

    AC Bryan

    1996-01-01

    Full Text Available High frequency oscillatory (HFO ventilation using low tidal volume and peak airway pressures is extremely efficient at eliminating carbon dioxide and raising pH in the newborn infant with acute respiratory failure. Improvement in oxygenation requires a strategy of sustained or repetitive inflations to 25 to 30 cm H2O in order to place the lung on the deflation limb of the pressure-volume curve. This strategy has also been shown to decrease the amount of secondary lung injury in animal models. Experience of the use of HFO ventilation as a rescue therapy as well as several published controlled trials have shown improved outcomes and a decrease in the use of extracorporeal membrane oxygenation when it has been used in newborns.

  13. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    cooling capacity, energy saving, low investment cost and low noise level; while the limitations include condensation risk and the limit on the room geometry. Furthermore, the crucial design parameters are summarized and their effects on the system performance are discussed. In addition to the stand...... is not well structured with this system. These become the motivations in developing the design guide. This design guide aims to establish a systematic understanding of diffuse ceiling ventilation and provide assistance in designing of such a system. The guide is targeted at design engineers, architects...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...

  14. Mapping European Welfare Models: State of the Art of Strategies for Professional Integration and Reintegration of Persons with Chronic Diseases

    Directory of Open Access Journals (Sweden)

    Chiara Scaratti

    2018-04-01

    Full Text Available Background: Persons with chronic diseases (PwCDs often experience work-related problems, and innovative actions to improve their participation in the labor market are needed. In the frame of the European (EU Pathways Project, the aim of the study is to compare existing strategies (policies, systems, and services for professional (re-integration of PwCDs and mental health conditions available at both European and national level between different European welfare models: Scandinavian, Continental, Anglo-Saxon, Mediterranean, and “Post-Communist”. Method: The European strategies were identified by an overview of relevant academic and grey literature searched through Medline and internet searches, while national strategies were explored through questionnaires and in-depth interviews with national relevant stakeholders. Results: The mapping of existing strategies revealed that, both at European and national level, PwCDs are often considered as part of the group of “persons with disabilities” and only in this case they can receive employment support. European countries put in place actions to support greater labor market participation, but these differ from country to country. Conclusion: Strategies targeting “persons with disabilities” do not necessarily address all the needs of persons with chronic diseases. Countries should consider the importance of employment for all to achieve smart, sustainable, and inclusive growth.

  15. Health-promotion in the context of ageing and migration: a call for person-centred integrated practice

    Directory of Open Access Journals (Sweden)

    Qarin Lood

    2014-03-01

    Full Text Available Normal 0 false false false SV JA X-NONE Objective: For the aim of improving the implementation of a health-promoting intervention for older persons who are born abroad, this study aimed to explore health care professionals’ experiences of facilitators and barriers for their possibilities to support healthy ageing in the context of migration. Methods: Qualitative data were collected from four focus groups with health professionals who all had experience of working with older persons who are born abroad. Data were analysed with guidance from the method developed by Krueger and Casey, progressing from an empirical to an abstract level. Results: Five different conditions were found to influence supporting healthy ageing in the context of migration: sense of belonging through significant others; emotional bonds to a place called home; expectations on health and support during the ageing process; mutual understanding as a means for communication; and heterogeneity as a point of departure. The one comprehensive theme, complexity, describes how those aspects are interrelated in a complex and unpredictable way. Conclusions: The results point at the need for focusing on each person's experiences and health expectations, and the study provides a foundation for future research on the integration of whole-system and person-centred practice.

  16. Health-promotion in the context of ageing and migration: a call for person-centred integrated practice

    Directory of Open Access Journals (Sweden)

    Qarin Lood

    2014-03-01

    Full Text Available Normal 0 false false false SV JA X-NONE Objective: For the aim of improving the implementation of a health-promoting intervention for older persons who are born abroad, this study aimed to explore health care professionals’ experiences of facilitators and barriers for their possibilities to support healthy ageing in the context of migration.Methods: Qualitative data were collected from four focus groups with health professionals who all had experience of working with older persons who are born abroad. Data were analysed with guidance from the method developed by Krueger and Casey, progressing from an empirical to an abstract level.Results: Five different conditions were found to influence supporting healthy ageing in the context of migration: sense of belonging through significant others; emotional bonds to a place called home; expectations on health and support during the ageing process; mutual understanding as a means for communication; and heterogeneity as a point of departure. The one comprehensive theme, complexity, describes how those aspects are interrelated in a complex and unpredictable way.Conclusions: The results point at the need for focusing on each person's experiences and health expectations, and the study provides a foundation for future research on the integration of whole-system and person-centred practice.

  17. Perceiving where another person is looking: The integration of head and body information in estimating another person’s gaze.

    Directory of Open Access Journals (Sweden)

    Pieter eMoors

    2015-06-01

    Full Text Available The process through which an observer allocates his/her attention based on the attention of another person is known as joint attention. To be able to do this, the observer effectively has to compute where the other person is looking. It has been shown that observers integrate information from the head and the eyes to determine the gaze of another person. Most studies have documented that observers show a bias called the overshoot effect when eyes and head are misaligned. The present study addresses whether body information is also used as a cue to compute perceived gaze direction. In Experiment 1, we observed a similar overshoot effect in both behavioral and saccadic responses when manipulating body orientation. In Experiment 2, we explored whether the overshoot effect was due to observers assuming that the eyes are oriented further than the head when head and body orientation are misaligned. We removed horizontal eye information by presenting the stimulus from a side view. Head orientation was now manipulated in a vertical direction and the overshoot effect was replicated. In summary, this study shows that body orientation is indeed used as a cue to determine where another person is looking.

  18. Mapping European Welfare Models: State of the Art of Strategies for Professional Integration and Reintegration of Persons with Chronic Diseases.

    Science.gov (United States)

    Scaratti, Chiara; Leonardi, Matilde; Silvaggi, Fabiola; Ávila, Carolina C; Muñoz-Murillo, Amalia; Stavroussi, Panayiota; Roka, Olga; Burger, Helena; Fheodoroff, Klemens; Tobiasz-Adamczyk, Beata; Sabariego, Carla; Esteban, Eva; Gruber, Sonja; Svestkova, Olga; Halvorsen, Rune; Kadyrbaeva, Asel; Ferraina, Sabrina

    2018-04-17

    Background: Persons with chronic diseases (PwCDs) often experience work-related problems, and innovative actions to improve their participation in the labor market are needed. In the frame of the European (EU) Pathways Project, the aim of the study is to compare existing strategies (policies, systems, and services) for professional (re-)integration of PwCDs and mental health conditions available at both European and national level between different European welfare models: Scandinavian, Continental, Anglo-Saxon, Mediterranean, and “Post-Communist”. Method : The European strategies were identified by an overview of relevant academic and grey literature searched through Medline and internet searches, while national strategies were explored through questionnaires and in-depth interviews with national relevant stakeholders. Results : The mapping of existing strategies revealed that, both at European and national level, PwCDs are often considered as part of the group of “persons with disabilities” and only in this case they can receive employment support. European countries put in place actions to support greater labor market participation, but these differ from country to country. Conclusion : Strategies targeting “persons with disabilities” do not necessarily address all the needs of persons with chronic diseases. Countries should consider the importance of employment for all to achieve smart, sustainable, and inclusive growth.

  19. Harnessing natural ventilation benefits.

    Science.gov (United States)

    O'Leary, John

    2013-04-01

    Making sure that a healthcare establishment has a good supply of clean fresh air is an important factor in keeping patients, staff, and visitors, free from the negative effects of CO2 and other contaminants. John O'Leary of Trend Controls, a major international supplier of building energy management solutions (BEMS), examines the growing use of natural ventilation, and the health, energy-saving, and financial benefits, that it offers.

  20. Purge ventilation operability

    International Nuclear Information System (INIS)

    Marella, J.R.

    1995-01-01

    A determination of minimum requirements for purge exhaust ventilation system operability has been performed. HLWE and HLW Regulatory Program personnel have evaluated the various scenarios of equipment conditions and HLWE has developed the requirements for purge exhaust systems. This report is provided to document operability requirements to assist Tank Farm personnel to determine whether a system is operable/inoperable and to define required compensatory actions

  1. Ventilation i industrien

    DEFF Research Database (Denmark)

    Valbjørn, O.

    I en række afsnit belyses problemer med træk, kulde, varme, og luftforurening på industriens arbejdspladser, og hvordan man ved ventilation og bygningsudformning kan bekæmpe disse gener. Hvert afsnit kan i princippet læses for sig, og anvisningen kan derfor bruges som håndbog, både af de der er...

  2. Proposal of a service delivery integration index of home care for older persons: application in several European cities

    Directory of Open Access Journals (Sweden)

    Jean-Claude Henrard

    2006-07-01

    Full Text Available Purpose: To propose an integration index of home care delivery to older persons, to study its validity and to apply it to home care services of European cities. Theory: Home care delivery integration was based on two dimensions referring to process-centred integration and organisational structure approach. Method: Items considered as part of both dimensions according to an expert consensus (face validity were extracted from a standardised questionnaire used in “Aged in Home care” (AdHoc study to capture basic characteristics of home care services. Their summation leads to a services' delivery integration index. This index was applied to AdHoc services. A factor analysis was computed in order to empirically test the validity of the theoretical constructs. The plot of the settings was performed. Results: Application of the index ranks home care services in four groups according to their score. Factor analysis identifies a first factor which opposes working arrangement within service to organisational structure bringing together provisions for social care. A second factor corresponds to basic nursing care and therapies. Internal consistency for those three domains ranges from 0.78 to 0.93. When plotting the different settings different models of service delivery appear. Conclusion: The proposed index shows that behind a total score several models of care delivery are hidden. Comparison of service delivery integration should take into account this heterogeneity.

  3. Integrating User Interface and Personal Innovativeness into the TAM for Mobile Learning in Cyber University

    Science.gov (United States)

    Joo, Young Ju; Lee, Hyeon Woo; Ham, Yookyoung

    2014-01-01

    This study aims to add new variables, namely user interface, personal innovativeness, and satisfaction in learning, to Davis's technology acceptance model and also examine whether learners are willing to adopt mobile learning. Thus, this study attempted to explain the structural causal relationships among user interface, personal…

  4. Integrating the Differentiated: A Review of the Personal Construct Approach to Cognitive Complexity

    Czech Academy of Sciences Publication Activity Database

    Kovářová, Marie; Filip, Miroslav

    2015-01-01

    Roč. 28, č. 4 (2015), s. 342-366 ISSN 1072-0537 R&D Projects: GA ČR(CZ) GAP407/12/2432 Institutional support: RVO:68081740 Keywords : cognitive complexity * psychology of personal constructs * repertory grid technique Subject RIV: AN - Psychology Impact factor: 0.333, year: 2015

  5. The Whole Person at Work: An Integrative Vocational Intervention Model for Women's Workplace Issues.

    Science.gov (United States)

    Giordano, Francesca G.

    1995-01-01

    Explains a vocational intervention model, "the whole person at work group for faculty, staff, and community women": a group counseling approach designed to help women cope with work-related difficulties. Includes a brief overview of women's workplace issues and their connection to some current thoughts regarding women's identity development. (RJM)

  6. Integrative Treatment in Persons with Intellectual Disability and Mental Health Problems

    Science.gov (United States)

    Dosen, A.

    2007-01-01

    Background: Clinical experience has proven thus far that a monodisciplinary treatment approach to behavioural and psychiatric problems in persons with intellectual disability (ID), such as psychotropic medication or behaviour modification programmes, has yielded limited success. It is clear that the complexity of behavioural and psychiatric…

  7. Integrating Recovery and the Narrative Attachment Systems Perspective to Working through Borderline Personality Disorder

    Science.gov (United States)

    Bernardon, Stephanie; Pernice-Duca, Francesca

    2012-01-01

    Borderline personality disorder (BPD) presents a number of symptoms and adjustment issues for individuals, but it is also associated with a myriad of risks for the larger family system. A systemic perspective is crucial to comprehending the development of BPD. Promoting healthy relationships with one or more supportive adult enables the child to…

  8. MEASUREMENT OF FRICTIONAL PRESSURE DIFFERENTIALS DURING A VENTILATION SURVEY

    International Nuclear Information System (INIS)

    B.S. Prosser, PE; I.M. Loomis, PE, PhD

    2003-01-01

    During the course of a ventilation survey, both airflow quantity and frictional pressure losses are measured and quantified. The measurement of airflow has been extensively studied as the vast majority of ventilation standards/regulations are tied to airflow quantity or velocity. However, during the conduct of a ventilation survey, measurement of airflow only represents half of the necessary parameters required to directly calculate the airway resistance. The measurement of frictional pressure loss is an often misunderstood and misapplied part of the ventilation survey. This paper compares the two basic methods of frictional pressure drop measurements; the barometer and the gauge and tube. Personal experiences with each method will be detailed along with the authors' opinions regarding the applicability and conditions favoring each method

  9. Perceived Changes to Obstetric Care and the Integration of Personal and Professional Life as a Pregnant Prenatal Genetic Counselor.

    Science.gov (United States)

    Rietzler, Jennifer L; Birkeland, Laura E; Petty, Elizabeth M

    2018-02-08

    The impact of practicing as a prenatal genetic counselor while pregnant is unclear given the limited amount of published literature on this issue. To address this gap in knowledge, a total of 215 current and past prenatal genetic counselors provided insights regarding this personal yet professional juncture through completion of an online survey that allowed for both close-ended and open-ended responses. While participants agreed that experiencing pregnancy affected their perspectives and counseling in several ways, this paper focuses on one particular finding-that of the changes in their own obstetric care perceived by genetic counselors while working within the prenatal setting and being pregnant themselves. As a result of these changes, considerations about when to disclose a pregnancy to colleagues along with how to integrate personal and professional needs as a pregnant prenatal genetic counselor surfaced. Additional findings, practice implications, and research recommendations are discussed.

  10. Computational modeling of particle transport and distribution emitted from a Laserjet printer in a ventilated room with different ventilation configurations

    International Nuclear Information System (INIS)

    Ansaripour, Mehrzad; Abdolzadeh, Morteza; Sargazizadeh, Saleh

    2016-01-01

    Highlights: • The distribution of emitted particles form a laserjet printer was studied in the breathing zone. • Effects of different ventilation configurations on the breathing zone concentration were investigated. • Mixing ventilation system has a low mean particle concentration in the breathing zone. - Abstract: In the present research, computational modeling of particle transport and distribution emitted from a Laserjet printer was carried out in a ventilated room. A seated manikin was integrated into the study room and the manikin was evaluated in two cases: heated and unheated. Effects of different ventilation configurations of the room on the particle distribution were studied, including three displacement ventilation systems and a mixing ventilation system. The printer was located on different sides of the manikin and the particle concentrations in the breathing zone of the manikin due to the printer’s particles were evaluated in all the ventilation configurations. The averaged particle concentration in the breathing zone of the manikin was calculated and validated with the experimental and numerical data available in the literature. The results of the present study showed that in case of the heated manikin, the particle concentration due to the printer pollutants is significant in the breathing zone of the manikin. The results also showed that when the printer is located on the front side of the manikin, the particle concentration in the breathing zone is quite high in most of the used ventilation configurations. Furthermore, it was found that the mixing ventilation system has a lower mean particle concentration in the breathing zone compared to the most displacement ventilation systems.

  11. Noninvasive Ventilation in Premature Neonates.

    Science.gov (United States)

    Flanagan, Keri Ann

    2016-04-01

    The use of noninvasive ventilation is a constantly evolving treatment option for respiratory disease in the premature infant. The goals of these noninvasive ventilation techniques are to improve gas exchange in the premature infant's lungs and to minimize the need for intubation and invasive mechanical ventilation. The goals of this article are to consider various uses of nasal interfaces, discuss skin care and developmental positioning concerns faced by the bedside nurse, and discuss the medical management aimed to reduce morbidity and mortality. This article explores the nursing role, the advances in medical strategies for noninvasive ventilation, and the team approach to noninvasive ventilation use in this population. Search strategy included a literature review on medical databases, such as EBSCOhost, CINAHL, PubMed, and NeoReviews. Innovative products, nursing research on developmental positioning and skin care, and advanced medical management have led to better and safer outcomes for premature infants requiring noninvasive ventilation. The medical focus of avoiding long-term mechanical ventilation would not be possible without the technology to provide noninvasive ventilation to these premature infants and the watchful eye of the nurse in terms of careful positioning, preventing skin breakdown and facial scarring, and a proper seal to maximize ventilation accuracy. This article encourages nursing-based research to quantify some of the knowledge about skin care and positioning as well as research into most appropriate uses for noninvasive ventilation devices.

  12. Performance evaluation of ventilation radiators

    International Nuclear Information System (INIS)

    Myhren, Jonn Are; Holmberg, Sture

    2013-01-01

    A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust-ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions. The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and identify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered. The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20% without sacrificing ventilation efficiency or thermal comfort. Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught. -- Highlights: ► Low temperature heat emitters are currently of interest due to their potential for increasing energy efficiency. ► A ventilation radiator is a combined ventilation and heat emission unit which can be adapted to low temperature heating systems. ► We examine how ventilation radiators can be made to be more efficient in terms of energy consumption and thermal comfort. ► Current work focuses on heat transfer mechanisms and convection fin configuration of ventilation radiators

  13. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings.

    Science.gov (United States)

    MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph

    2015-11-18

    Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption-Economic and environmental costs. We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8

  14. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings

    Directory of Open Access Journals (Sweden)

    Piers MacNaughton

    2015-11-01

    Full Text Available Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person, 30% enhanced ventilation, and 40 cfm/person and four different heating, ventilation and air conditioning (HVAC system strategies (Variable Air Volume (VAV with reheat and a Fan Coil Unit (FCU, both with and without an energy recovery ventilator. We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities. The same change in ventilation

  15. Amyotrophic lateral sclerosis and assisted ventilation: how patients decide.

    Science.gov (United States)

    Lemoignan, Josée; Ells, Carolyn

    2010-06-01

    Throughout the course of their illness, people with amyotrophic lateral sclerosis (ALS) must make many treatment decisions; however, none has such a significant impact on quality of life and survival as decisions about assisted ventilation. The purpose of this study was to better understand the experience of decision-making about assisted ventilation for ALS patients. Using qualitative phenomenology methodology, 10 semi-structured interviews were conducted with persons with ALS and their caregivers to elicit factors that are pertinent to their decision-making process about assisted ventilation. Six main themes emerged from the interviews. (1) the meaning of the intervention - participants made a sharp distinction between non-invasive ventilation, which they viewed as a means to relieve symptoms of respiratory failure, and invasive ventilation, which they viewed as taking over their breathing and thereby saving their life when they otherwise would die, (2) the importance of context - including functional status, available supports, and financial implications, (3) the importance of values - with respect to communication, relationships, autonomy, life, and quality of life, (4) the effect of fears - particularly respiratory distress, chocking, running out of air, and the process of death itself, (5) the need for information - how use of assisted ventilation would impact daily life, how death from respiratory failure would occur, how caregivers and persons with ALS differ in their information needs and common misconceptions, and (6) adaptation to or acceptance of the intervention - a lengthy process that involved gradual familiarization with the equipment and its benefits. People with ALS and caregivers value autonomy in decision-making about assisted ventilation. Their decision-making process is neither wholly rational nor self-interested, and includes factors that health professionals should anticipate and address. Discussions about assisted ventilation and timing

  16. Validation of a Human Exhalation Flow Simulation in a Room with Vertical Ventilation

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; Adana, M. Ruiz de

    2012-01-01

    flow around persons in combination with the surrounding conditions. Analyses of the flow in the room (macroenvironment) show a number of parameters that play an important role in minimising of airborne cross-infection. The air flow rate to the room must be high, and the air distribution pattern can...... be designed to have high ventilation effectiveness. Furthermore, personalized ventilation may reduce the risk of cross-infection. Personalized ventilation can be used especially in hospital wards, aircraft cabins and, in general, where people are located at defined positions. Analyses of the flow...

  17. Open Access Integrated Therapeutic and Diagnostic Platforms for Personalized Cardiovascular Medicine

    Directory of Open Access Journals (Sweden)

    Todd T. Schlegel

    2013-08-01

    Full Text Available It is undeniable that the increasing costs in healthcare are a concern. Although technological advancements have been made in healthcare systems, the return on investment made by governments and payers has been poor. The current model of care is unsustainable and is due for an upgrade. In developed nations, a law of diminishing returns has been noted in population health standards, whilst in the developing world, westernized chronic illnesses, such as diabetes and cardiovascular disease have become emerging problems. The reasons for these trends are complex, multifactorial and not easily reversed. Personalized medicine has the potential to have a significant impact on these issues, but for it to be truly successful, interdisciplinary mass collaboration is required. We propose here a vision for open-access advanced analytics for personalized cardiac diagnostics using imaging, electrocardiography and genomics.

  18. Personal resilience, cognitive appraisals, and coping: an integrative model of adjustment to abortion.

    Science.gov (United States)

    Major, B; Richards, C; Cooper, M L; Cozzarelli, C; Zubek, J

    1998-03-01

    We hypothesized that the effects of personality (self-esteem, control, and optimism) on postabortion adaptation (distress, well-being, and decision satisfaction) would be fully mediated by preabortion cognitive appraisals (stress appraisals and self-efficacy appraisals) and postabortion coping. We further proposed that the effects of preabortion appraisals on adaptation would be fully mediated by postabortion coping. Results of a longitudinal study of 527 women who had first-trimester abortions supported our hypotheses. Women with more resilient personalities appraised their abortion as less stressful and had higher self-efficacy for coping with the abortion. More positive appraisals predicted greater acceptance/reframing coping and lesser avoidance/denial, venting, support seeking, and religious coping. Acceptance-reframing predicted better adjustment on all measures, whereas avoidance-denial and venting related to poorer adjustment on all measures. Greater support seeking was associated with reduced distress, and greater religious coping was associated with less decision satisfaction.

  19. Integration of nidotherapy into the management of mental illness and antisocial personality: a qualitative study.

    Science.gov (United States)

    Spencer, Sarah-Jane; Rutter, Deborah; Tyrer, Peter

    2010-01-01

    Nidotherapy is a new treatment aimed at the systematic alteration of the environment in order to make a better fit for a person with chronic mental health difficulties. Preliminary work has suggested that it might have particular value in those with antisocial personality disorder. To examine the views of patients with mental illness combined with antisocial personality features about the acceptability and value of nidotherapy when given over a six-month period as an adjunct to conventional care. A two-phase study was used. First, a set of key informant interviews was carried out to determine how nidotherapy was perceived in order to identify potentially important themes. Specific topic guides derived from these themes were drawn up for use in the second stage of the study, involving semi-structured interviews with a sample of patients, members of their care teams and their nidotherapists. Nine patients were purposively selected to ensure that a range of demographic and clinical factors was covered. Analysis of the results showed that the common threads of the perception of nidotherapy were that it was both feasible and acceptable to those with antisocial personality disturbance and that the nidotherapists were felt to be valuable allies in what was otherwise seen as a hostile world. It was also seen to improve adherence to other therapies. It was much less valuable when the staff on the clinical teams were not able to embrace the collaborative approach necessary with this therapy. Nidotherapy is an acceptable form of management and was perceived in this study to have largely positive results for both patients and clinical teams as it offered intervention beyond that provided by conventional teams. It was felt to require more than six months of treatment and was less successful when there was inadequate communication between the nidotherapist and clinical teams and when the philosophy of care was not congruent.

  20. White matter integrity and its association with affective and interpersonal symptoms in borderline personality disorder

    OpenAIRE

    Whalley, Heather C; Nickson, Thomas; Pope, Merrick; Nicol, Katie; Romaniuk, Liana; Bastin, Mark E; Semple, Scott I; McIntosh, Andrew M; Hall, Jeremy

    2015-01-01

    BACKGROUND: \\ud \\ud Borderline personality disorder (BPD) is a severe psychiatric disorder involving a range of symptoms including marked affective instability and disturbances in interpersonal interactions. Neuroimaging studies are beginning to provide evidence of altered processing in fronto-limbic network deficits in the disorder, however, few studies directly examine structural connections within this circuitry together with their relation to proposed causative processes and clinical feat...

  1. Perceptions of a Person with Mental Retardation as a Function of Participation in Integrated versus Segregated Recreation/Sport Activities: An Experimental Analysis

    Science.gov (United States)

    Kellow, J. Thomas; Frey, Georgia C.; Sandt, Dawn Rosser

    2007-01-01

    This study is a conceptual replication of previous work by Storey, Stern, & Parker (1990) that examined the influence of participation in integrated vs. segregated recreation/sports activities on evaluations of a person with mental retardation by persons without a disability. The Storey et al., (1990) study observed that people with mental…

  2. Integrating personalized medical test contents with XML and XSL-FO.

    Science.gov (United States)

    Toddenroth, Dennis; Dugas, Martin; Frankewitsch, Thomas

    2011-03-01

    In 2004 the adoption of a modular curriculum at the medical faculty in Muenster led to the introduction of centralized examinations based on multiple-choice questions (MCQs). We report on how organizational challenges of realizing faculty-wide personalized tests were addressed by implementation of a specialized software module to automatically generate test sheets from individual test registrations and MCQ contents. Key steps of the presented method for preparing personalized test sheets are (1) the compilation of relevant item contents and graphical media from a relational database with database queries, (2) the creation of Extensible Markup Language (XML) intermediates, and (3) the transformation into paginated documents. The software module by use of an open source print formatter consistently produced high-quality test sheets, while the blending of vectorized textual contents and pixel graphics resulted in efficient output file sizes. Concomitantly the module permitted an individual randomization of item sequences to prevent illicit collusion. The automatic generation of personalized MCQ test sheets is feasible using freely available open source software libraries, and can be efficiently deployed on a faculty-wide scale.

  3. On the integration of personality assessment methods: the Rorschach and MMPI.

    Science.gov (United States)

    Meyer, G J

    1997-04-01

    Despite being the most studied and used personality assessment tools, data from the Rorschach and MMPI generally disagree (Archer & Krishnamurthy, 1993a, 1993b). Independence is proposed to result from at least 3 factors: (a) the methods tap unique levels of personality, (b) personality has a complex organization, and (c) response styles generate considerable method variance that must be considered in nomothetic research. These ideas led to 5 hypotheses, each of which received support. Rorschach and MMPI response styles are uncorrelated, although response styles are quite consistent within a method family. MMPI-2 and Rorschach constructs of dysphoria, psychosis, or wariness are uncorrelated when response styles are ignored. However, robust convergent validity is evident when patients have similar response styles on each method (e.g., for dysphoria, M r = .59) and dysphoria is expressed in opposing ways on each method when response styles are discordant (i.e., M r = -.54). Data from the latter analyses were correlated with genuine clinical phenomena and implications were discussed for clinical practice and research.

  4. Person-based differences in pay reactions: A compensation-activation theory and integrative conceptual review.

    Science.gov (United States)

    Fulmer, Ingrid Smithey; Shaw, Jason D

    2018-06-07

    Compensation research has focused traditionally on how pay design characteristics (e.g., pay level, individual or group incentives) relate to average employee outcomes and, in toto, on how these outcomes affect organizational performance. Recently, scholars have begun to pay more attention to how individuals vary in the strength of their reactions to pay. Empirical research in several disciplines examines how the interplay of pay systems and person-based characteristics (psychological individual differences, demographics, and relative performance or position in a group) relate to important work-related outcomes. We develop a compensation-activation theory that frames compensation design characteristics as workplace "situations" providing cues that activate individuals' corresponding fundamental social motives made salient due to chronic or transient person-based characteristics. Where activation occurs, stronger-than-average responses to the compensation "situation" are expected. Using the theory as a lens, we synthesize and reinterpret existing research on person-based reactions to pay characteristics, including sorting, incentive/motivational effects, and effects on collective pay system reactions and unit/organizational outcomes. We conclude with a research agenda aimed at refining compensation-activation theory and advancing the study of compensation as it affects individual and organizational outcomes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures.

    Directory of Open Access Journals (Sweden)

    Yunzhou Shi

    Full Text Available Excessive ultraviolet (UV radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.

  6. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures.

    Science.gov (United States)

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive; Pielak, Rafal M

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.

  7. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures

    Science.gov (United States)

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A.; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application. PMID:29293664

  8. New options to integrate care and financing for persons dually eligible for Medicare and Medicaid.

    Science.gov (United States)

    Hayes, Katherine Jett; Thorpe, Jane Hyatt

    2012-01-01

    This paper reviews barriers to clinical and financial integration in services for dual eligibles prior to passage of the ACA, identifies models used by states to integrate care through contract and waiver authorities available to CMS prior to passage of the ACA, describes two new demonstrations proposed by CMS through the Medicare-Medicaid Coordination Office and Innovation Center, and discusses several new models available for consideration by federal and state policymakers. These options draw on experience from existing programs and waivers to provide suggested changes to existing programs, as well as a permanent state plan option for a fully integrated, capitated care model. This model could be made available to states prior to the completion of the demonstration process begun by the Medicare-Medicaid Coordination Office and Innovation Center.

  9. A hybrid energy efficient building ventilation system

    International Nuclear Information System (INIS)

    Calay, Rajnish Kaur; Wang, Wen Chung

    2013-01-01

    The present paper presents a high performance cooling/heating ventilation system using a rotary heat exchanger (RHE), together with a reverse-cycle heat pump (RCHP) that can be integrated with various heat sources. Energy consumption in the building sector is largely dominated by the energy consumed in maintaining comfortable conditions indoors. For example in many developed countries the building heating, ventilation and air conditioning (HVAC) systems consume up to 50% of the total energy consumed in buildings. Therefore energy efficient HVAC solutions in buildings are critical for realising CO 2 targets at local and global level. There are many heating/cooling concepts that rely upon renewable energy sources and/or use natural low temperature heat sources in the winter and heat sinks in the summer. In the proposed system, waste energy from the exhaust air stream is used to precondition the outdoor air before it is supplied into the building. The hybrid system provides heating in the winter and cooling in the summer without any need for additional heating or cooling devices as required in conventional systems. Its performance is better than a typical reheat or air conditioning system in providing the same indoor air quality (IAQ) levels. It is shown that an energy saving up to 60% (heat energy) is achieved by using the proposed hybrid system in building ventilation applications. -- Highlights: • Hybrid ventilation system: the hybrid ventilation system uses a rotating regenerator and a reversible heat pump. • Heat recovery: heat recovery from exhaust air stream by rotary wheel type heat exchanger. • Reversible cycle heat pump (RCHP): additional heating or cooling of the supply air is provided by the RCHP. • Energy efficiency: energy savings of up to 60% using the proposed system are achievable

  10. Emotion detection deficits and changes in personality traits linked to loss of white matter integrity in primary progressive aphasia

    Directory of Open Access Journals (Sweden)

    Namita Multani

    2017-01-01

    Full Text Available Non-cognitive features including personality changes are increasingly recognized in the three PPA variants (semantic-svPPA, non fluent-nfvPPA, and logopenic-lvPPA. However, differences in emotion processing among the PPA variants and its association with white matter tracts are unknown. We compared emotion detection across the three PPA variants and healthy controls (HC, and related them to white matter tract integrity and cortical degeneration. Personality traits in the PPA group were also examined in relation to white matter tracts. Thirty-three patients with svPPA, nfvPPA, lvPPA, and 32 HC underwent neuropsychological assessment, emotion evaluation task (EET, and MRI scan. Patients' study partners were interviewed on the Clinical Dementia Rating Scale (CDR and completed an interpersonal traits assessment, the Interpersonal Adjective Scale (IAS. Diffusion tensor imaging of uncinate fasciculus (UF, superior longitudinal fasciculus (SLF and inferior longitudinal fasciculus (ILF, and voxel-based morphometry to derive gray matter volumes for orbitofrontal cortex (OFC, anterior temporal lobe (ATL regions were performed. In addition, gray matter volumes of white matter tract-associated regions were also calculated: inferior frontal gyrus (IFG, posterior temporal lobe (PTL, inferior parietal lobe (IPL and occipital lobe (OL. ANCOVA was used to compare EET performance. Partial correlation and multivariate linear regression were conducted to examine association between EET and neuroanatomical regions affected in PPA. All three variants of PPA performed significantly worse than HC on EET, and the svPPA group was least accurate at recognizing emotions. Performance on EET was related to the right UF, SLF, and ILF integrity. Regression analysis revealed EET performance primarily relates to the right UF integrity. The IAS subdomain, cold-hearted, was also associated with right UF integrity. Disease-specific emotion recognition and personality changes occur

  11. Energy and cost associated with ventilating office buildings in a tropical climate.

    Science.gov (United States)

    Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W

    2015-01-01

    Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore's tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore's. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person--which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave--can be much larger than the incremental cost of ventilation.

  12. Numerical investigation of diffuse ceiling ventilation in an office under different operating conditions

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    2014-01-01

    is a numerical study of the performance of a six person office equipped with diffuse ventilation ceiling. In total six extreme, yet realistic, operation scenarios were simulated to study the performance including different occupancy, ventilation rates and supply air temperatures. The performance was studied...

  13. Pretest Predictions for Ventilation Tests

    International Nuclear Information System (INIS)

    Y. Sun; H. Yang; H.N. Kalia

    2007-01-01

    The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, concrete pipe walls, and insulation that will be developed during the ventilation tests involving various test conditions. The results will be used as input to the following three areas: (1) Decisions regarding testing set-up and performance. (2) Assessing how best to scale the test phenomena measured. (3) Validating numerical approach for modeling continuous ventilation. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the ventilation tests, and develop and describe numerical methods that can be used to calculate the effects of continuous ventilation. Sensitivity studies to assess the impact of variation of linear power densities (linear heat loads) and ventilation air flow rates are included. The calculation is limited to thermal effect only

  14. Design Principles for Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples.......For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation...

  15. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury.

    Science.gov (United States)

    Custer, Jason W; Watson, Christopher M; Dwyer, Joe; Kaczka, David W; Simon, Brett A; Easley, R Blaine

    2011-11-01

    Modern health care systems may be inadequately prepared for mass casualty respiratory failure requiring mechanical ventilation. Current health policy has focused on the "stockpiling" of emergency ventilators, though little is known about the performance of these ventilators under conditions of respiratory failure in adults and children. In this study, we seek to compare emergency ventilator performance characteristics using a test lung simulating pediatric lung injury. Evaluation of ventilator performance using a test lung. Laboratory. None. Six transport/emergency ventilators capable of adult/child application were chosen on the basis of manufacturer specifications, Autovent 3000, Eagle Univent 754, EPV 100, LP-10, LTV 1200, and Parapac 200D. Manufacturer specifications for each ventilator were reviewed and compared with known standards for alarms and functionality for surge capacity ventilators. The delivered tidal volume, gas flow characteristics, and airway pressure waveforms were evaluated in vitro using a mechanical test lung to model pediatric lung injury and integrated software. Test lung and flow meter recordings were analyzed over a range of ventilator settings. Of the six ventilators assessed, only two had the minimum recommended alarm capability. Four of the six ventilators tested were capable of being set to deliver a tidal volume of less than 200 mL. The delivered tidal volume for all ventilators was within 8% of the nominal setting at a positive end expiratory pressure of zero but was reduced significantly with the addition of positive end expiratory pressure (range, ±10% to 30%; p ventilators tested performed comparably at higher set tidal volumes; however, only three of the ventilators tested delivered a tidal volume across the range of ventilator settings that was comparable to that of a standard intensive care unit ventilator. Multiple ventilators are available for the provision of ventilation to children with respiratory failure in a mass

  16. Mechanical ventilation in neurosurgical patients

    Directory of Open Access Journals (Sweden)

    Keshav Goyal

    2013-01-01

    Full Text Available Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical patient requiring artificial support of the respiration.

  17. Mechanical Ventilation and Bronchopulmonary Dysplasia.

    Science.gov (United States)

    Keszler, Martin; Sant'Anna, Guilherme

    2015-12-01

    Mechanical ventilation is an important potentially modifiable risk factor for the development of bronchopulmonary dysplasia. Effective use of noninvasive respiratory support reduces the risk of lung injury. Lung volume recruitment and avoidance of excessive tidal volume are key elements of lung-protective ventilation strategies. Avoidance of oxidative stress, less invasive methods of surfactant administration, and high-frequency ventilation are also important factors in lung injury prevention. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Design Principles for Natural and Hybrid Ventilation

    OpenAIRE

    Heiselberg, Per

    2000-01-01

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples.

  19. 46 CFR 42.15-45 - Ventilators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Ventilators. 42.15-45 Section 42.15-45 Shipping COAST... Conditions of Assignment of Freeboard § 42.15-45 Ventilators. (a) Ventilators in position 1 or 2 to spaces... any ventilator exceeds 351/2 inches in height it shall be specially supported. (b) Ventilators passing...

  20. Active Teaching Methods: Personal Experience of Integrating Spiritual and Moral Values

    Science.gov (United States)

    Kasim, Tengku Sarina Aini Tengku; Yusoff, Yusmini Md

    2014-01-01

    Islamic education has always recognized spiritual and moral values as significant elements in developing a "balanced" human being. One way of demonstrating spiritual and moral concepts is through effective teaching methods that integrate and forefront these values. This article offers an investigation of how the authors' teaching…

  1. Teacher Identity in Language Teaching: Integrating Personal, Contextual, and Professional Factors

    Science.gov (United States)

    Pennington, Martha C.; Richards, Jack C.

    2016-01-01

    This article reviews notions of identity and teacher identity, how these relate to the specific characteristics of language teaching, and how teacher identity can evolve or be developed through experience and teacher education. The notion of teacher identity highlights the individual characteristics of the teacher and how these are integrated with…

  2. Integrasi Personal Balanced Scorecard, Psikologi Integral, dan Positive Organization Behaviour/ Scholarship sebagai Pendekatan Komprehensif di Perusahaan/Organisasi

    Directory of Open Access Journals (Sweden)

    Nurlaila Effendy

    2017-07-01

    Full Text Available Kinerja suatu organisasi diukur dari physical assets, financial capital dan human capital. Organisasi memerlukan sistem yang tepat dalam meningkatkan kinerja.Tujuan Performance Management System yang diterapkan dalam organisasi adalah untuk mengoptimalkan potensi individu, tim, pemimpin, dan organisasi. Pendekatan komprehensif diperlukan untuk dapat mengoptimalkan potensi dan pencapaian kinerja yang optimal.PBSC adalahperformance management system dengan pendekatan perspektif finance dan non finance serta mengintegrasikan dengan formulasi strategi (visi, misi organisasi, tujuan organisasi dengan tujuan departemen dan tujuan karyawan. PBSC adalah konsep baru dengan pendekatan personal,baik terkait perusahaan maupun bukan terkait pekerjaansebagai ukuran diri. Pengembangan suatu organisasi yang terintegrasi adalah adanya kesadaran individu-individu dalam organisasi yang memunculkan personal meaning atau kebermaknaan diri di dalam organisasi, sehingga akan membentuk budaya organisasi dan iklim organisasi yang efektif dan harmoni. Penerapan Positive Organization Behavior dan Positive Organization Scholarship pada organisasi akan membangun Positive Emotional Climate dan Organization Relational Strength. Pendekatan secara integratif antara Personal Balance Scorecard, Positive Organizational Scholarship, Positive Organizational Behavior dan Psikologi Integral akan memperkuat kinerja organisasi dan memiliki kesempatan menuju organisasi Positif . Individu dalam organisasi akan memiliki vitalitas dan mengalami flow, dan organisasimemiliki flourishing

  3. Personal and Emotional Factors in the Labour Integration of University Graduates in the Field of Education. Implications for University Teaching

    Directory of Open Access Journals (Sweden)

    Juan L. Castejón

    2011-01-01

    Full Text Available The main aim of this paper is to analyse the role of intellectual, personal and emotional competencies as well as technical knowledge - academic achievement - in the employment of university graduates, with the purpose of incorporating these competencies into training programmes developed within the European Framework of Higher Education. This study is based on an initial sample of 118 university graduates in the field of education. We have gathered information about academic achievement and the intellectual, personal and emotional traits of this sample. From these data, and given the importance of non-intellectual aspects of intelligence associated with professional success, the specific contribution -incremental validity - of personal and emotional intelligence in explaining theemployment - labour integration - of university graduates in the field of education is studied. From this point onwards, we attempt to identify the key socio-emotional competencies in the field of education in order to establish the implications of including this type of skills in university training programmes within the European Higher Education Area.

  4. Personality Predicts Mortality Risk: An Integrative Data Analysis of 15 International Longitudinal Studies.

    Science.gov (United States)

    Graham, Eileen K; Rutsohn, Joshua P; Turiano, Nicholas A; Bendayan, Rebecca; Batterham, Philip J; Gerstorf, Denis; Katz, Mindy J; Reynolds, Chandra A; Sharp, Emily S; Yoneda, Tomiko B; Bastarache, Emily D; Elleman, Lorien G; Zelinski, Elizabeth M; Johansson, Boo; Kuh, Diana; Barnes, Lisa L; Bennett, David A; Deeg, Dorly J H; Lipton, Richard B; Pedersen, Nancy L; Piccinin, Andrea M; Spiro, Avron; Muniz-Terrera, Graciela; Willis, Sherry L; Schaie, K Warner; Roan, Carol; Herd, Pamela; Hofer, Scott M; Mroczek, Daniel K

    2017-10-01

    This study examined the Big Five personality traits as predictors of mortality risk, and smoking as a mediator of that association. Replication was built into the fabric of our design: we used a Coordinated Analysis with 15 international datasets, representing 44,094 participants. We found that high neuroticism and low conscientiousness, extraversion, and agreeableness were consistent predictors of mortality across studies. Smoking had a small mediating effect for neuroticism. Country and baseline age explained variation in effects: studies with older baseline age showed a pattern of protective effects (HReffects for extraversion. This study demonstrated coordinated analysis as a powerful approach to enhance replicability and reproducibility, especially for aging-related longitudinal research.

  5. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University......In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation concept...... of Denmark. Through building integration in high performance offices the system is optimized to incorporate multiple functions like heating, cooling and ventilation, thus saving the expenses of separate cooling and heating systems. The simulation results are derived using the state-of-the-art building...

  6. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation

    International Nuclear Information System (INIS)

    Schranz, C; Möller, K; Becher, T; Schädler, D; Weiler, N

    2014-01-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (p I ), inspiration and expiration time (t I , t E ) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal p I and adequate t E can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's ‘optimized’ settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end

  7. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation.

    Science.gov (United States)

    Schranz, C; Becher, T; Schädler, D; Weiler, N; Möller, K

    2014-03-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (pI), inspiration and expiration time (tI, tE) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal pI and adequate tE can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's 'optimized' settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory pressure.

  8. Naturlig ventilation i enfamiliehuse

    DEFF Research Database (Denmark)

    Bergsøe, N.C.

    Meddelelsen beskriver resultaterne af en række beregninger foretaget ved anvendelse af et computerprogram. Beregningerne har til formål at belyse forskellige parametres indvirkning på funktionen af et naturligt ventilationssystem. Blandt andet belyses systemets afhængighed af aftrækskanalernes di...... dimension, udeluftventilarealet og placeringen af aftrækskanalernes udmunding i tagfladen. Derudover gengives i kortfattet form de væsentligste konklusioner af udvalgte publikationer, som behandler særlige forhold vedrørende naturlig ventilation i praksis....

  9. Work–Life Integration and Workplace Rights for Domestic Workers in Support to Elderly Persons

    Directory of Open Access Journals (Sweden)

    Diane-Gabrielle Tremblay

    2015-05-01

    Full Text Available Our article shows that there is a real challenge in balancing work and family for employees working in support services in domestic work for elderly persons; their workplace rights on this issue are quite limited, and they depend largely on managers’ understanding and support. Given their difficult working conditions, these workers actually find quite a challenge in trying to reconcile work and family. Our article is based on a qualitative research mobilizing 33 semi-structured interviews with employees of the home care sector in the field of the social economy mainly but also in the private sector. We first present the concept of work–family and personal life, then the area of home care and domestic work for the elderly. Then, we present the particular challenges observed in reconciling work and family life, where possible by comparing men and women. The results highlight two major sources of differentiation: age and single parenthood. Those who are older highlight the fact that children have grown up, and they have (finally some time for themselves, even if their working conditions are difficult (broken schedules, etc.. In contrast, single women live a much more difficult situation concerning work–family, partly because of the lack of workplace rights on this issue and because of the poor working conditions for many (broken hours of work, low wages, difficult working conditions. We conclude with some recommendations, including the Right to request, which appears to be the best option, although it would need some further analysis.

  10. Placebo analgesia and reward processing: integrating genetics, personality, and intrinsic brain activity.

    Science.gov (United States)

    Yu, Rongjun; Gollub, Randy L; Vangel, Mark; Kaptchuk, Ted; Smoller, Jordan W; Kong, Jian

    2014-09-01

    Our expectations about an event can strongly shape our subjective evaluation and actual experience of events. This ability, applied to the modulation of pain, has the potential to affect therapeutic analgesia substantially and constitutes a foundation for non-pharmacological pain relief. A typical example of such modulation is the placebo effect. Studies indicate that placebo may be regarded as a reward, and brain activity in the reward system is involved in this modulation process. In the present study, we combined resting-state functional magnetic resonance imaging (rs-fMRI) measures, genotype at a functional COMT polymorphism (Val158Met), and personality measures in a model to predict the magnitude of placebo conditioning effect indicated by subjective pain rating reduction to calibrated noxious stimuli. We found that the regional homogeneity (ReHo), an index of local neural coherence, in the ventral striatum, was significantly associated with conditioning effects on pain rating changes. We also found that the number of Met alleles at the COMT polymorphism was linearly correlated to the suppression of pain. In a fitted regression model, we found the ReHo in the ventral striatum, COMT genotype, and Openness scores accounted for 59% of the variance in the change in pain ratings. The model was further tested using a separate data set from the same study. Our findings demonstrate the potential of combining resting-state connectivity, genetic information, and personality to predict placebo effect. Copyright © 2014 Wiley Periodicals, Inc.

  11. Integrating Iris and Signature Traits for Personal Authentication Using User-SpecificWeighting

    Directory of Open Access Journals (Sweden)

    Serestina Viriri

    2012-03-01

    Full Text Available Biometric systems based on uni-modal traits are characterized by noisy sensor data, restricted degrees of freedom, non-universality and are susceptible to spoof attacks. Multi-modal biometric systems seek to alleviate some of these drawbacks by providing multiple evidences of the same identity. In this paper, a user-score-based weighting technique for integrating the iris and signature traits is presented. This user-specific weighting technique has proved to be an efficient and effective fusion scheme which increases the authentication accuracy rate of multi-modal biometric systems. The weights are used to indicate the importance of matching scores output by each biometrics trait. The experimental results show that our biometric system based on the integration of iris and signature traits achieve a false rejection rate (FRR of 0.08% and a false acceptance rate (FAR of 0.01%.

  12. ISSUES OF INTEGRATION OF SKILLS FAVOURABLE TO HEALTH IN PERSONS WITH DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Vida Gudžinskienė

    2018-05-01

    Full Text Available Diabetes mellitus is not only a medical, but also a public issue. The number of people with diabetes is increasing every year. Diabetes causes complications of diseases. In addition to infertility issues and foot injuries that worsen the health condition, patients develop diabetic retinopathy, diabetic neuropathy, chronic kidney disease, cardiovascular diseases (strokes, ischemic heart diseases, peripheral vascular diseases. Accordingly, training courses for patients and focus on the health of the patients themselves are very important. The object of the research is training of persons with diabetes mellitus and skills favourable to health that help to prevent complications. The aim of the article is to reveal the process of learning of patients with diabetes and the application of skills favourable to health, which help to prevent complications in life. Tasks: 1 determine what kind of training courses are organized in Lithuania for persons with diabetes mellitus; 2 determine what kind of knowledge about health and disease control is provided by medical personnel; 3 reveal what kind of knowledge about health and what skills patients adapt in everyday life. Methods of research: theoretical – analysis of scientific literature, generalization; empirical – questionnaire survey, data analysis was performed by using the SPSS 23.0 program. The t-test was used to compare averages between groups, significant difference was considered to be p < 0,05. Data analysis was performed by applying calculations of non-parametric and parametric criteria. There were 61 patients with diabetes mellitus, aged from 13 to 78 years, who participated in the research. The research sought to reveal what training courses are organized for persons with diabetes mellitus and how patients themselves preserve their health. During the research, participants were questioned about the training courses they have attended; how patients with diabetes mellitus control their disease

  13. Radioaerosol ventilation imaging in ventilator-dependent patients. Technical considerations

    International Nuclear Information System (INIS)

    Vezina, W.; Chamberlain, M.; Vinitski, S.; King, M.; Nicholson, R.; Morgan, W.K.

    1985-01-01

    The differentiation of pulmonary embolism (PE) from regional ventilatory abnormalities accompanied by reduced perfusion requires contemporary perfusion and ventilation studies. Distinguishing these conditions in ventilator-dependent patients is aided by administering a Tc-99m aerosol to characterize regional ventilation, and by performing a conventional Tc-99m MAA perfusion study. The technique uses a simple in-house constructed apparatus. Simple photographic techniques suffice, but computer subtraction of perfusion from the combined perfusion-ventilation image renders interpretation easier if aerosol administration follows perfusion imaging. Multiple defects can be examined in a single study. Excluding normal or near-normal perfusion studies, PE was thought to be present in eight of 16 patients after perfusion imaging alone, but in only one of eight after added aerosol imaging. Angiography confirmed the diagnosis in that patient. Of the eight patients who had abnormal perfusion but were thought unlikely to have PE from the perfusion study alone, two had normal ventilation, and subsequently were shown to have PE by angiography. Because angiography was only performed on patients who were thought to have a high probability of PE on sequential perfusion-ventilation imaging, the true incidence of PE may have been higher. Aerosol ventilation imaging is a useful adjunct to perfusion imaging in patients on ventilators. It requires an efficient delivery system, particularly if aerosol administration follows perfusion imaging, as it does in this study

  14. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  15. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    OpenAIRE

    Davidow Amy; Lafond Ian; Saleh Soha; Qiu Qinyin; Fluet Gerard G; Merians Alma S; Adamovich Sergei V

    2011-01-01

    Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective me...

  16. [Lung protective ventilation. Ventilatory modes and ventilator parameters].

    Science.gov (United States)

    Schädler, Dirk; Weiler, Norbert

    2008-06-01

    Mechanical ventilation has a considerable potential for injuring the lung tissue. Therefore, attention has to be paid to the proper choice of ventilatory mode and settings to secure lung-protective ventilation whenever possible. Such ventilator strategy should account for low tidal volume ventilation (6 ml/kg PBW), limited plateau pressure (30 to 35 cm H2O) and positive end-expiratory pressure (PEEP). It is unclear whether pressure controlled or volume controlled ventilation with square flow profile is beneficial. The adjustment of inspiration and expiration time should consider the actual breathing mechanics and anticipate the generation of intrinsic PEEP. Ventilatory modes with the possibility of supporting spontaneous breathing should be used as soon as possible.

  17. Positional effects on distribution of ventilation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shim, C.; Chun, K.J.; Williams, M.H. Jr.; Blaufox, M.D.

    1986-01-01

    Ventilation is distributed predominantly to the dependent lung in normal persons in the decubitus position. We evaluated the distribution of ventilation in four patients with mild-to-moderate chronic obstructive pulmonary disease using 81mKr gas. Patients were tested in the sitting and right and left decubitus positions with and without the application of positive end expiratory pressure (PEEP). In contrast to findings in controls, ventilation was predominantly distributed to the nondependent lung in patients in the decubitus position. Mean ventilation in the right lung decreased from 51% of the total in the sitting position to 31% in the right decubitus position; it increased with the application of 10 cm PEEP. Reduced ventilation in the dependent lung most likely is caused by closure of the airways after a decrease in volume. Application of PEEP resulted in increased lung volume and preferential distribution of ventilation to the dependent lung

  18. p-Medicine: From data sharing and integration via VPH models to personalized medicine

    Science.gov (United States)

    Rossi, S; Christ-Neumann, ML; Rüping, S; Buffa, FM; Wegener, D; McVie, G; Coveney, PV; Graf, N; Delorenzi, M

    2011-01-01

    The Worldwide innovative Networking in personalized cancer medicine (WIN) initiated by the Institute Gustave Roussy (France) and The University of Texas MD Anderson Cancer Center (USA) has dedicated its 3rd symposium (Paris, 6–8 July 2011) to discussion on gateways to increase the efficacy of cancer diagnostics and therapeutics (http://www.winconsortium.org/symposium.html). Speakers ranged from clinical oncologist to researchers, industrial partners, and tools developers; a famous patient was present: Janelle Hail, a 30-year breast cancer survivor, founder and CEO of the National Breast Cancer Foundation, Inc. (NBCF). The p-medicine consortium found this venue a perfect occasion to present a poster about its activities that are in accordance with the take home message of the symposium. In this communication, we summarize what we presented with particular attention to the interaction between the symposium’s topic and content and our project. PMID:22276060

  19. Neutron shielding point kernel integral calculation code for personal computer: PKN-pc

    International Nuclear Information System (INIS)

    Kotegawa, Hiroshi; Sakamoto, Yukio; Nakane, Yoshihiro; Tomita, Ken-ichi; Kurosawa, Naohiro.

    1994-07-01

    A personal computer version of PKN code, PKN-pc, has been developed to calculate neutron and secondary gamma-ray 1cm depth dose equivalents in water, ordinary concrete and iron for neutron source. Characteristics of PKN code are, to able to calculate dose equivalents in multi-layer three-dimensional system, which are described with two-dimensional surface, for monoenergetic neutron source from 0.01 to 14.9 MeV, 252 Cf fission and 241 Am-Be neutron source quick and easily. In addition to these features, the PKN-pc is possible to process interactive input and to get graphical system configuration and graphical results easily. (author)

  20. p-Medicine: From data sharing and integration via VPH models to personalized medicine.

    Science.gov (United States)

    Rossi, S; Christ-Neumann, Ml; Rüping, S; Buffa, Fm; Wegener, D; McVie, G; Coveney, Pv; Graf, N; Delorenzi, M

    2011-01-01

    The Worldwide innovative Networking in personalized cancer medicine (WIN) initiated by the Institute Gustave Roussy (France) and The University of Texas MD Anderson Cancer Center (USA) has dedicated its 3rd symposium (Paris, 6-8 July 2011) to discussion on gateways to increase the efficacy of cancer diagnostics and therapeutics (http://www.winconsortium.org/symposium.html).Speakers ranged from clinical oncologist to researchers, industrial partners, and tools developers; a famous patient was present: Janelle Hail, a 30-year breast cancer survivor, founder and CEO of the National Breast Cancer Foundation, Inc. (NBCF).The p-medicine consortium found this venue a perfect occasion to present a poster about its activities that are in accordance with the take home message of the symposium.In this communication, we summarize what we presented with particular attention to the interaction between the symposium's topic and content and our project.

  1. Passive Smoking in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter V.

    The aim of this research is to see if the displacement ventilation principle can protect a person from exposure to passive tobacco smoking. This is done by full-scale experiments with two breathing thermal manikins, smoke visualisations, and tracer gas measurements. In some situations, exhaled...... smoke will stratify in a certain height due to the vertical temperature gradient. This horizontal layer of exhaled tobacco smoke may lead to exposure. In other situations, the smoke is mixed into the upper zone, and the passive smoker is protected to some extent by the displacement principle...

  2. Improved Performance With Ventilation

    Science.gov (United States)

    Kawakami, Ellison; Lee, Seung Jae; Karn, Ashish; Hong, Jiarong; Arndt, Roger

    2013-11-01

    Drag reduction and/or speed augmentation of marine vehicles by means of supercavitation is a topic of great interest. During the initial launch of a supercavitating vehicle, ventilation is required to supply an artificial cavity until conditions at which a natural supercavity can be sustained are reached. Various aspects of the flow physics of a supercavitating vehicle have been under investigation for several years at Saint Anthony Falls Laboratory. Both steady flow and simulated flow below a wave train have been studied. Using a high speed camera and the proper software, it is possible to synchronize cavity dimensions with pressure measurements taken inside the cavity to permit an in-depth study of unsteadiness. It was found that flow unsteadiness caused a decrease in the overall length of the supercavity while having only a minimal effect on the maximum diameter. Results regarding supercavity shape, ventilation demand, cavitation parameters and closure methods are reviewed in light of new studies that focused on various closure mechanisms. Sponsored by ONR.

  3. Ventilator-associated pneumonia.

    Science.gov (United States)

    Shaw, Michael Jan

    2005-05-01

    This review summarises some of the notable papers on ventilator-associated pneumonia (VAP) from January 2003 to October 2004. Ventilator-associated pneumonia remains an important drain on hospital resources. All population groups are affected, but patients with VAP are more likely to be older, sicker, and male, with invasive medical devices in situ. Early VAP diagnosis is desirable to reduce VAP mortality and to retard emergence of multidrug-resistant microbes. This may be possible using preliminary culture results or intracellular organism in polymorphonuclear cells. In most intensive care units, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii are the commonest organisms isolated in VAP. However, causative organisms vary between and within hospitals. Consequently, individual intensive care units should develop empirical antibiotic policies to target the pathogenic bacteria prevalent in their patient populations. Preventative strategies aimed at reducing aerodigestive tract colonisation by pathogenic organisms, and also their subsequent aspiration, are becoming increasingly important. Educating medical staff about these simple measures is therefore pertinent. To reduce the occurrence of multidrug-resistant organisms, limiting the duration of antibiotic treatment to 8 days and antimicrobial rotation should be contemplated. Empirical therapy with antipseudomonal penicillins plus beta-lactamase inhibitors should be considered. If methicillin-resistant Staphylococcus aureus VAP is a possibility, linezolid may be better than vancomycin. Prevention remains the key to reducing VAP prevalence.

  4. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    Directory of Open Access Journals (Sweden)

    Davidow Amy

    2011-05-01

    Full Text Available Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Methods Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. Results The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Conclusions Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  5. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis.

    Science.gov (United States)

    Merians, Alma S; Fluet, Gerard G; Qiu, Qinyin; Saleh, Soha; Lafond, Ian; Davidow, Amy; Adamovich, Sergei V

    2011-05-16

    Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  6. REGIONAL DEPOSITION OF COARSE PARTICLES AND VENTILATION DISTRIBUTION IN PATIENTS WITH CYSTIC FIBROSIS

    Science.gov (United States)

    The efficacy of inhaled pharmaceuticals depends, in part, on their site of respiratory deposition. Markedly nonuniform ventilation distribution may occur in persons with obstructive airways diseases and may affect particle deposition. We studied the relationship between regional ...

  7. Innovation in home mechanical ventilation

    NARCIS (Netherlands)

    Hazenberg, Andrea

    2017-01-01

    Patients on home mechanical ventilation (HMV) are ventilator dependent, usually for the rest of their lives. In the past decades, the number of patients on HMV increased to nearly 3,000 in 2016 in the Netherlands. Current indications for HMV are patients diagnosed with either neuromuscular disease,

  8. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  9. Modes of mechanical ventilation for the operating room.

    Science.gov (United States)

    Ball, Lorenzo; Dameri, Maddalena; Pelosi, Paolo

    2015-09-01

    Most patients undergoing surgical procedures need to be mechanically ventilated, because of the impact of several drugs administered at induction and during maintenance of general anaesthesia on respiratory function. Optimization of intraoperative mechanical ventilation can reduce the incidence of post-operative pulmonary complications and improve the patient's outcome. Preoxygenation at induction of general anaesthesia prolongs the time window for safe intubation, reducing the risk of hypoxia and overweighs the potential risk of reabsorption atelectasis. Non-invasive positive pressure ventilation delivered through different interfaces should be considered at the induction of anaesthesia morbidly obese patients. Anaesthesia ventilators are becoming increasingly sophisticated, integrating many functions that were once exclusive to intensive care. Modern anaesthesia machines provide high performances in delivering the desired volumes and pressures accurately and precisely, including assisted ventilation modes. Therefore, the physicians should be familiar with the potential and pitfalls of the most commonly used intraoperative ventilation modes: volume-controlled, pressure-controlled, dual-controlled and assisted ventilation. Although there is no clear evidence to support the advantage of any one of these ventilation modes over the others, protective mechanical ventilation with low tidal volume and low levels of positive end-expiratory pressure (PEEP) should be considered in patients undergoing surgery. The target tidal volume should be calculated based on the predicted or ideal body weight rather than on the actual body weight. To optimize ventilation monitoring, anaesthesia machines should include end-inspiratory and end-expiratory pause as well as flow-volume loop curves. The routine administration of high PEEP levels should be avoided, as this may lead to haemodynamic impairment and fluid overload. Higher PEEP might be considered during surgery longer than 3 h

  10. Person perception involves functional integration between the extrastriate body area and temporal pole.

    Science.gov (United States)

    Greven, Inez M; Ramsey, Richard

    2017-02-01

    The majority of human neuroscience research has focussed on understanding functional organisation within segregated patches of cortex. The ventral visual stream has been associated with the detection of physical features such as faces and body parts, whereas the theory-of-mind network has been associated with making inferences about mental states and underlying character, such as whether someone is friendly, selfish, or generous. To date, however, it is largely unknown how such distinct processing components integrate neural signals. Using functional magnetic resonance imaging and connectivity analyses, we investigated the contribution of functional integration to social perception. During scanning, participants observed bodies that had previously been associated with trait-based or neutral information. Additionally, we independently localised the body perception and theory-of-mind networks. We demonstrate that when observing someone who cues the recall of stored social knowledge compared to non-social knowledge, a node in the ventral visual stream (extrastriate body area) shows greater coupling with part of the theory-of-mind network (temporal pole). These results show that functional connections provide an interface between perceptual and inferential processing components, thus providing neurobiological evidence that supports the view that understanding the visual environment involves interplay between conceptual knowledge and perceptual processing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Ventilation of an hydrofoil wake

    Science.gov (United States)

    Arndt, Roger; Lee, Seung Jae; Monson, Garrett

    2013-11-01

    Ventilation physics plays a role in a variety of important engineering applications. For example, hydroturbine ventilation is used for control of vibration and cavitation erosion and more recently for improving the dissolved oxygen content of the flow through the turbine. The latter technology has been the focus of an ongoing study involving the ventilation of an hydrofoil wake to determine the velocity and size distribution of bubbles in a bubbly wake. This was carried out by utilizing particle shadow velocimetry (PSV). This technique is a non-scattering approach that relies on direct in-line volume illumination by a pulsed source such as a light-emitting diode (LED). The data are compared with previous studies of ventilated flow. The theoretical results of Hinze suggest that a scaling relationship is possible that can lead to developing appropriate design parameters for a ventilation system. Sponsored by ONR and DOE.

  12. Natural ventilation for free stall dairy barns

    OpenAIRE

    Gay, Susan Wood

    2009-01-01

    Natural ventilation is a result of a combination good construction, correct temperature, humidity control, air exchange. This publication discusses how to achieve natural ventilation in your structure.

  13. Narcissistic personality disorder: an integrative review of recent empirical data and current definitions.

    Science.gov (United States)

    Roepke, Stefan; Vater, Aline

    2014-05-01

    Although concepts of pathological narcissism are as old as psychology and psychiatry itself, only a small number of clinical studies are based on the criteria for narcissistic personality disorder (NPD), as defined in the Diagnostic and Statistical Manuals of Mental Disorders (DSM). As a result, NPD appears to be one of the most controversially discussed nosological entities in psychiatry. Whereas the majority of empirical studies used self or other ratings of NPD criteria to address issues of reliability and validity of the diagnostic category (i.e., internal consistency, factor structure, discriminant validity), only recent research has applied experimental designs to investigate specific features of NPD (e.g., self-esteem, empathy, shame). The aim of this review is to summarize available empirical data on NPD and relate these findings to current definitions of NPD (according to the DSM-5, [1]). In order to do so, this review follows the five steps to establishing diagnostic validity proposed by Robins and Guze [2], i.e., (1) clinical description, (2) laboratory studies, (3) delimitation from other disorders, (4) family studies, and (5) follow up studies. Finally, this review suggests pathways for future research that may assist further nosological evaluation of NPD and contribute to the overall goal, the improvement of treatment for patients.

  14. Genetics of borderline personality disorder: systematic review and proposal of an integrative model.

    Science.gov (United States)

    Amad, Ali; Ramoz, Nicolas; Thomas, Pierre; Jardri, Renaud; Gorwood, Philip

    2014-03-01

    Borderline personality disorder (BPD) is one of the most common mental disorders and is characterized by a pervasive pattern of emotional lability, impulsivity, interpersonal difficulties, identity disturbances, and disturbed cognition. Here, we performed a systematic review of the literature concerning the genetics of BPD, including familial and twin studies, association studies, and gene-environment interaction studies. Moreover, meta-analyses were performed when at least two case-control studies testing the same polymorphism were available. For each gene variant, a pooled odds ratio (OR) was calculated using fixed or random effects models. Familial and twin studies largely support the potential role of a genetic vulnerability at the root of BPD, with an estimated heritability of approximately 40%. Moreover, there is evidence for both gene-environment interactions and correlations. However, association studies for BPD are sparse, making it difficult to draw clear conclusions. According to our meta-analysis, no significant associations were found for the serotonin transporter gene, the tryptophan hydroxylase 1 gene, or the serotonin 1B receptor gene. We hypothesize that such a discrepancy (negative association studies but high heritability of the disorder) could be understandable through a paradigm shift, in which "plasticity" genes (rather than "vulnerability" genes) would be involved. Such a framework postulates a balance between positive and negative events, which interact with plasticity genes in the genesis of BPD. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. The Conscientious Responders Scale Helps Researchers Verify the Integrity of Personality Questionnaire Data.

    Science.gov (United States)

    Marjanovic, Zdravko; Bajkov, Lisa; MacDonald, Jennifer

    2018-01-01

    The Conscientious Responders Scale is a five-item embeddable validity scale that differentiates between conscientious and indiscriminate responding in personality-questionnaire data (CR & IR). This investigation presents further evidence of its validity and generalizability across two experiments. Study 1 tests its sensitivity to questionnaire length, a known cause of IR, and tries to provoke IR by manipulating psychological reactance. As expected, short questionnaires produced higher Conscientious Responders Scale scores than long questionnaires, and Conscientious Responders Scale scores were unaffected by reactance manipulations. Study 2 tests concerns that the Conscientious Responders Scale's unusual item content could potentially irritate and baffle responders, ironically increasing rates of IR. We administered two nearly identical questionnaires: one with an embedded Conscientious Responders Scale and one without the Conscientious Responders Scale. Psychometric comparisons revealed no differences across questionnaires' means, variances, interitem response consistencies, and Cronbach's alphas. In sum, the Conscientious Responders Scale is highly sensitive to questionnaire length-a known correlate of IR-and can be embedded harmlessly in questionnaires without provoking IR or changing the psychometrics of other measures.

  16. Protocol for the ostomized person in the trans-hospital and outpatient period: Integrative Review

    Directory of Open Access Journals (Sweden)

    Stella Godoy Silva Lima

    2017-06-01

    Full Text Available Objective: To review the literature about the application of the evidence-based protocol concept for clinical assessment and interventions in nursing consultation to ostomized people. Method: integrative review to increase the knowledge about stomata. A search was made in the databases BIREME, CINAHL, SCOPUS, WEB OF SCIENCE and PUBMED with descriptors Ostomy OR Colostomy OR Colonic Pouches OR Surgical Stomata OR Colorectal Neoplasms OR Colorectal Cancer AND Protocols. It was selected 21 articles in the period of 2011-2015. Results: The articles were systematized into five categories: quality of life, nursing assistance, protocols, complications and surgery. The categories are complementary and demonstrate a work carried out by a multiprofessional team. Conclusion: the themes analysis made it possible to identify the need for expansion in research that addresses specific aspects such as teaching strategies in the levels of assistance in the trans-operative, postoperative and in the outpatient phase in nursing consultations.

  17. Control technology for integrated circuit fabrication at Micro-Circuit Engineering, Incorporated, West Palm Beach, Florida

    Science.gov (United States)

    Mihlan, G. I.; Mitchell, R. I.; Smith, R. K.

    1984-07-01

    A survey to assess control technology for integrated circuit fabrication was conducted. Engineering controls included local and general exhaust ventilation, shielding, and personal protective equipment. Devices or work stations that contained toxic materials that were potentially dangerous were controlled by local exhaust ventilation. Less hazardous areas were controlled by general exhaust ventilation. Process isolation was used in the plasma etching, low pressure chemical vapor deposition, and metallization operations. Shielding was used in ion implantation units to control X-ray emissions, in contact mask alignes to limit ultraviolet (UV) emissions, and in plasma etching units to control radiofrequency and UV emissions. Most operations were automated. Use of personal protective equipment varied by job function.

  18. Individual behavioral phenotypes: an integrative meta-theoretical framework. Why "behavioral syndromes" are not analogs of "personality".

    Science.gov (United States)

    Uher, Jana

    2011-09-01

    Animal researchers are increasingly interested in individual differences in behavior. Their interpretation as meaningful differences in behavioral strategies stable over time and across contexts, adaptive, heritable, and acted upon by natural selection has triggered new theoretical developments. However, the analytical approaches used to explore behavioral data still address population-level phenomena, and statistical methods suitable to analyze individual behavior are rarely applied. I discuss fundamental investigative principles and analytical approaches to explore whether, in what ways, and under which conditions individual behavioral differences are actually meaningful. I elaborate the meta-theoretical ideas underlying common theoretical concepts and integrate them into an overarching meta-theoretical and methodological framework. This unravels commonalities and differences, and shows that assumptions of analogy to concepts of human personality are not always warranted and that some theoretical developments may be based on methodological artifacts. Yet, my results also highlight possible directions for new theoretical developments in animal behavior research. Copyright © 2011 Wiley Periodicals, Inc.

  19. The Role of Interpersonal Connection, Personal Narrative, and Metacognition in Integrative Psychotherapy for Schizophrenia: A Case Report.

    Science.gov (United States)

    Hamm, Jay A; Leonhardt, Bethany L

    2016-02-01

    The recovery movement has not only challenged traditional pessimism regarding schizophrenia but also presented opportunities for the possibilities for psychotherapy for people with the disorder. Though in the past psychotherapy models were often pitted against one another, recently there have been emergent reports of a range of integrative models sharing an emphasis on recovery and a number of conceptual elements. These shared elements include attention to the importance of interpersonal processes, personal narrative, and metacognition, with interest in their role in not only the disorder but also the processes by which people pursue recovery. This article explores one application of this framework in the psychotherapy of a woman with prolonged experience of schizophrenia and significant functional impairments. © 2015 Wiley Periodicals, Inc.

  20. Integrating smart-phone based momentary location tracking with fixed site air quality monitoring for personal exposure assessment.

    Science.gov (United States)

    Su, Jason G; Jerrett, Michael; Meng, Ying-Ying; Pickett, Melissa; Ritz, Beate

    2015-02-15

    Epidemiological studies investigating relationships between environmental exposures from air pollution and health typically use residential addresses as a single point for exposure, while environmental exposures in transit, at work, school or other locations are largely ignored. Personal exposure monitors measure individuals' exposures over time; however, current personal monitors are intrusive and cannot be operated at a large scale over an extended period of time (e.g., for a continuous three months) and can be very costly. In addition, spatial locations typically cannot be identified when only personal monitors are used. In this paper, we piloted a study that applied momentary location tracking services supplied by smart phones to identify an individual's location in space-time for three consecutive months (April 28 to July 28, 2013) using available Wi-Fi networks. Individual exposures in space-time to the traffic-related pollutants Nitrogen Oxides (NOX) were estimated by superimposing an annual mean NOX concentration surface modeled using the Land Use Regression (LUR) modeling technique. Individual's exposures were assigned to stationary (including home, work and other stationary locations) and in-transit (including commute and other travel) locations. For the individual, whose home/work addresses were known and the commute route was fixed, it was found that 95.3% of the time, the individual could be accurately identified in space-time. The ambient concentration estimated at the home location was 21.01 ppb. When indoor/outdoor infiltration, indoor sources of air pollution and time spent outdoors were taken into consideration, the individual's cumulative exposures were 28.59 ppb and 96.49 ppb, assuming a respective indoor/outdoor ratio of 1.33 and 5.00. Integrating momentary location tracking services with fixed-site field monitoring, plus indoor-outdoor air exchange calibration, makes exposure assessment of a very large population over an extended time period

  1. Addressing narcissistic personality features in the context of medical care: integrating diverse perspectives to inform clinical practice.

    Science.gov (United States)

    Magidson, J F; Collado-Rodriguez, A; Madan, A; Perez-Camoirano, N A; Galloway, S K; Borckardt, J J; Campbell, W K; Miller, J D

    2012-04-01

    Narcissistic personality disorder (NPD) is characterized by an unrealistic need for admiration, lack of empathy toward others, and feelings of superiority. NPD presents a unique and significant challenge in clinical practice, particularly in medical settings with limited provider contact time, as health professionals treat individuals who often require excessive admiration and have competing treatment needs. This practice review highlights real case examples across three distinct medically oriented clinical settings (inpatient and outpatient behavioral medicine and a Level I trauma center) to demonstrate the difficult and compromising situations that providers face when treating patients with general medical conditions and comorbid narcissistic personality features. The main goal of this article is to discuss the various challenges and obstacles associated with these cases in medical settings and discuss some strategies that may prove successful. A second goal is to bridge diverse conceptualizations of narcissism/NPD through the discussion of theoretical and empirical perspectives that can inform understanding of the clinical examples. Despite differing perspectives regarding the underlying motivation of narcissistic behavior, this practice review highlights that these paradigms can be integrated when sharing the same ultimate goal: to improve delivery of care across medically oriented clinical settings for patients with narcissistic features.

  2. [Oesophagitis during mechanical ventilation].

    Science.gov (United States)

    Gastinne, H; Canard, J M; Pillegand, B; Voultoury, J C; Catanzano, A; Claude, R; Gay, R

    1982-10-16

    Twenty-one patients whose condition required mechanical ventilation with nasogastric intubation were investigated for oesophagitis before the 3rd day and on the 15th day of treatment, including endoscopy and biopsy. Lesions of oesophagitis were detected in 14 cases during the initial examination and in 19 cases on the second endoscopy. The course of the lesions varied from one patient to another and appeared to be unrelated to the course of the primary disease. Oesophagitis in these patients is probably due to frequent episodes of gastro-oesophageal reflux encouraged by cough, impaired consciousness and the presence of a tube. Reflux may also be the cause of inapparent and recurrent lung aspiration.

  3. Cardiac gated ventilation

    International Nuclear Information System (INIS)

    Hanson, C.W. III; Hoffman, E.A.

    1995-01-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart

  4. Ventilation criteria for IDMS facility

    International Nuclear Information System (INIS)

    Lambert, D.P.

    1996-01-01

    Both Facility Evaluation Board (FEB) reviews of the Integrated DWPF Melter System (IDMS) have identified the inconsistency of the current IDMS Process Hazards Review (PHR) versus actual IDMS practice as regards the criteria to contain air borne pollutants that may be present in the Process Room (e.g. benzene and mercury). The PHR states that a 1.0 in. wc pressure differential be maintained between the IDMS Process Room and Building 672-T. In addition, the PHR further specifies that the linear velocity through openings into the Process Room (e.g. open doors) be equal to or greater than 150 fpm. Finally, the PHR recommended that mercury vapor and benzene monitors be installed in the Process Room ventilation exhaust to alert personnel to the presence of vapors of benzene and/or mercury before entering the Process Room. This report summarizes the results of reassessment of these criteria and the specific recommendation for permanent installation of mercury and benzene vapor monitors in the vapor exhaust of the Process Room

  5. Estimation of Lung Ventilation

    Science.gov (United States)

    Ding, Kai; Cao, Kunlin; Du, Kaifang; Amelon, Ryan; Christensen, Gary E.; Raghavan, Madhavan; Reinhardt, Joseph M.

    Since the primary function of the lung is gas exchange, ventilation can be interpreted as an index of lung function in addition to perfusion. Injury and disease processes can alter lung function on a global and/or a local level. MDCT can be used to acquire multiple static breath-hold CT images of the lung taken at different lung volumes, or with proper respiratory control, 4DCT images of the lung reconstructed at different respiratory phases. Image registration can be applied to this data to estimate a deformation field that transforms the lung from one volume configuration to the other. This deformation field can be analyzed to estimate local lung tissue expansion, calculate voxel-by-voxel intensity change, and make biomechanical measurements. The physiologic significance of the registration-based measures of respiratory function can be established by comparing to more conventional measurements, such as nuclear medicine or contrast wash-in/wash-out studies with CT or MR. An important emerging application of these methods is the detection of pulmonary function change in subjects undergoing radiation therapy (RT) for lung cancer. During RT, treatment is commonly limited to sub-therapeutic doses due to unintended toxicity to normal lung tissue. Measurement of pulmonary function may be useful as a planning tool during RT planning, may be useful for tracking the progression of toxicity to nearby normal tissue during RT, and can be used to evaluate the effectiveness of a treatment post-therapy. This chapter reviews the basic measures to estimate regional ventilation from image registration of CT images, the comparison of them to the existing golden standard and the application in radiation therapy.

  6. Practical mine ventilation optimization based on genetic algorithms for free splitting networks

    Energy Technology Data Exchange (ETDEWEB)

    Acuna, E.; Maynard, R.; Hall, S. [Laurentian Univ., Sudbury, ON (Canada). Mirarco Mining Innovation; Hardcastle, S.G.; Li, G. [Natural Resources Canada, Sudbury, ON (Canada). CANMET Mining and Mineral Sciences Laboratories; Lowndes, I.S. [Nottingham Univ., Nottingham (United Kingdom). Process and Environmental Research Division; Tonnos, A. [Bestech, Sudbury, ON (Canada)

    2010-07-01

    The method used to optimize the design and operation of mine ventilation has generally been based on case studies and expert knowledge. It has yet to benefit from optimization techniques used and proven in other fields of engineering. Currently, optimization of mine ventilation systems is a manual based decision process performed by an experienced mine ventilation specialist assisted by commercial ventilation distribution solvers. These analysis tools are widely used in the mining industry to evaluate the practical and economic viability of alternative ventilation system configurations. The scenario which is usually selected is the one that reports the lowest energy consumption while delivering the required airflow distribution. Since most commercial solvers do not have an integrated optimization algorithm network, the process of generating a series of potential ventilation solutions using the conventional iterative design strategy can be time consuming. For that reason, a genetic algorithm (GA) optimization routine was developed in combination with a ventilation solver to determine the potential optimal solutions of a primary mine ventilation system based on a free splitting network. The optimization method was used in a small size mine ventilation network. The technique was shown to have the capacity to generate good feasible solutions and improve upon the manual results obtained by mine ventilation specialists. 9 refs., 7 tabs., 3 figs.

  7. An integrated healthcare system for personalized chronic disease care in home-hospital environments.

    Science.gov (United States)

    Jeong, Sangjin; Youn, Chan-Hyun; Shim, Eun Bo; Kim, Moonjung; Cho, Young Min; Peng, Limei

    2012-07-01

    Facing the increasing demands and challenges in the area of chronic disease care, various studies on the healthcare system which can, whenever and wherever, extract and process patient data have been conducted. Chronic diseases are the long-term diseases and require the processes of the real-time monitoring, multidimensional quantitative analysis, and the classification of patients' diagnostic information. A healthcare system for chronic diseases is characterized as an at-hospital and at-home service according to a targeted environment. Both services basically aim to provide patients with accurate diagnoses of disease by monitoring a variety of physical states with a number of monitoring methods, but there are differences between home and hospital environments, and the different characteristics should be considered in order to provide more accurate diagnoses for patients, especially, patients having chronic diseases. In this paper, we propose a patient status classification method for effectively identifying and classifying chronic diseases and show the validity of the proposed method. Furthermore, we present a new healthcare system architecture that integrates the at-home and at-hospital environment and discuss the applicability of the architecture using practical target services.

  8. Responses to Human Bioeffluents at Levels Recommended by Ventilation Standards

    DEFF Research Database (Denmark)

    Zhang, Xiaojing; Wargocki, Pawel; Lian, Zhiwei

    2017-01-01

    The purpose of this study was to examine whether exposure to human bioeffluents, at the levels recommended by the current ventilation standards, would cause any effects on humans. Ten subjects were exposed in a low-emission stainless-steel climate chamber for 4.25 hours. The outdoor air supply rate...... was set to 33 or 4 l/s per person, creating two levels of bioeffluents with carbon dioxide (CO2) at 500 or 1600 ppm. Subjective ratings were collected, cognitive performance was examined and physiological responses were monitored. The results show that exposures to human bioeffluents at ventilation rate...

  9. Mechanical ventilation in abdominal surgery.

    Science.gov (United States)

    Futier, E; Godet, T; Millot, A; Constantin, J-M; Jaber, S

    2014-01-01

    One of the key challenges in perioperative care is to reduce postoperative morbidity and mortality. Patients who develop postoperative morbidity but survive to leave hospital have often reduced functional independence and long-term survival. Mechanical ventilation provides a specific example that may help us to shift thinking from treatment to prevention of postoperative complications. Mechanical ventilation in patients undergoing surgery has long been considered only as a modality to ensure gas exchange while allowing maintenance of anesthesia with delivery of inhaled anesthetics. Evidence is accumulating, however, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary function and clinical outcome in patients undergoing abdominal surgery. Non-protective ventilator settings, especially high tidal volume (VT) (>10-12mL/kg) and the use of very low level of positive end-expiratory pressure (PEEP) (PEEPventilator-associated lung injury in patients with healthy lungs. Stimulated by previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung protective mechanical ventilation. In this review, we aimed at providing the most recent and relevant clinical evidence regarding the use of mechanical ventilation in patients undergoing abdominal surgery. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  10. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  11. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-25

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  12. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-10-12

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  13. What does the scientific literature tell us about the ventilation-health relationship in public and residential buildings?

    DEFF Research Database (Denmark)

    Carrer, Paolo; Wargocki, Pawel; Fanetti, Annaclara

    2015-01-01

    . Effects on health were seen for a wide range of outdoor ventilation rates from 6 to 7 L/s per person, which were the lowest ventilation rates at which no effects on any health outcomes were observed in field studies, up to 25–40 L/s per person, which were in some studies the lowest outdoor ventilation...... rates at which no effects on health outcomes were seen. These data show that, in general, higher ventilation rates in many cases will reduce health outcomes, and that there are the minimum rates, at which some health outcomes can be avoided. But these data have many limitations, such as crude estimation...... of outdoor ventilation rates, diversity and variability of ventilation rates at which effects were seen, a diversity of outcomes (in case of health otcomes being mainly acute not chronic). Among other limitations there are incomplete data on the strength of pollution sources and exposures as well as a wide...

  14. Lecture Notes on Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    The main task of the ventilation system or the air-conditioning system is to supply· and remove air and airborne materials and to supply or remove heat from a room. The necessary level of fresh air will be supplied to· a room by a ventilation system, and heat from equipment or solar radiation can...... be removed by an air-conditioning system. An industrial ventilation system may both take care of the occupants' comfort and the industrial processes in the area....

  15. Design of Energy Efficient Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The focus in the development has for both systems been to minimise energy consumption while maintaining a comfortable and healthy indoor environment. The natural next step in this development is to develop ventilation concepts that utilises and combines the best features from each system......[Mechanical and natural ventilation] into a new type of ventilation system- Hybrid Ventilation....

  16. 21 CFR 868.5975 - Ventilator tubing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ventilator tubing. 868.5975 Section 868.5975 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5975 Ventilator tubing. (a) Identification. Ventilator tubing is a device intended for use as a conduit for gases between a ventilator and a patient...

  17. Preoperational test report, vent building ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  18. 46 CFR 45.131 - Ventilators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Ventilators. 45.131 Section 45.131 Shipping COAST GUARD....131 Ventilators. (a) Ventilators passing through superstructures other than enclosed superstructures must have coamings of steel or equivalent material at the freeboard deck. (b) Ventilators in position 1...

  19. Building envelope design for renewal of air by natural ventilation in moderate climates. Proposition of a designing methodology; Conception des enveloppes de batiments pour le renouvellement d'air par ventilation naturelle en climats temperes. Proposition d'une methodologie de conception

    Energy Technology Data Exchange (ETDEWEB)

    Mansouri, Y.

    2003-12-01

    The subject of this research is to produce methods and methodological tools for the architects to support the integration of natural ventilation systems in the building envelope design. Our research is situated to the interface between the architectural practice and the physical research on natural ventilation. We are interested in phenomena that can influence or force the strategy of ventilation. A morphological analysis of naturally ventilated buildings concerning the integration modes of natural ventilation systems is done permitting US to propose a typology and a topology of ventilation systems. We define criteria in relation to the thermal comfort, to the quality of air and the economy of energy to assess air renewal techniques. In complement of the sizing tool, we elaborate a methodology of conception for the integration of passives ventilation systems. Design guidelines permit US to conclude on an effective natural ventilation system which is well adapted to collective habitat. (author)

  20. Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France.

    Science.gov (United States)

    Canha, N; Mandin, C; Ramalho, O; Wyart, G; Ribéron, J; Dassonville, C; Hänninen, O; Almeida, S M; Derbez, M

    2016-06-01

    The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. 46 CFR 111.103-1 - Power ventilation systems except machinery space ventilation systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power ventilation systems except machinery space ventilation systems. 111.103-1 Section 111.103-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Power ventilation systems except machinery space ventilation systems. Each power ventilation system must...

  2. The role of ventilation. 2 v. Proceedings

    International Nuclear Information System (INIS)

    1994-01-01

    The 78 papers which constitute the proceedings of the conference are presented in two volumes. The papers in the first volume cover sessions dealing with the following broad topics: ventilation strategies; indoor air quality; energy impact of ventilation; building design for optimum ventilation; ventilation and energy. Volume 2 also covers ventilation strategies and ventilation and energy, and in addition: calculation, measurement and design tools; measurement and modelling. Separate abstract have been prepared for 4 papers in Volume 1 which deal with the role of ventilation in mitigating the hazard of radon in buildings. (UK)

  3. Evidence of inadequate ventilation in portable classrooms: results of a pilot study in Los Angeles County.

    Science.gov (United States)

    Shendell, D G; Winer, A M; Weker, R; Colome, S D

    2004-06-01

    The prevalence of prefabricated, portable classrooms (portables) for United States public schools has increased; in California, approximately one of three students learn inside portables. Limited research has been conducted on indoor air and environmental quality in American schools, and almost none in portables. Available reports and conference proceedings suggest problems from insufficient ventilation due to poor design, operation, and/or maintenance of heating, ventilation and air conditioning (HVAC) systems; most portables have one mechanical, wall-mounted HVAC system. A pilot assessment was conducted in Los Angeles County, including measurements of integrated ventilation rates based on a perfluorocarbon tracer gas technique and continuous monitoring of temperature (T) and relative humidity (RH). Measured ventilation rates were low [mean school day integrated average 0.8 per hour (range: 0.1-2.9 per hour)]. Compared with relevant standards, results suggested adequate ventilation and associated conditioning of indoor air for occupant comfort were not always provided to these classrooms. Future school studies should include integrated and continuous measurements of T, RH, and ventilation with appropriate tracer gas methods, and other airflow measures. Adequate ventilation has the potential to mitigate concentrations of chemical pollutants, particles, carbon dioxide, and odors in portable and traditional classrooms, which should lead to a reduction in reported health outcomes, e.g., symptoms of 'sick building syndrome', allergies, asthma. Investigations of school indoor air and environmental quality should include continuous temperature and relative humidity data with inexpensive instrumentation as indicators of thermal comfort, and techniques to measure ventilation rates.

  4. Newer nonconventional modes of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Preet Mohinder Singh

    2014-01-01

    Full Text Available The conventional modes of ventilation suffer many limitations. Although they are popularly used and are well-understood, often they fail to match the patient-based requirements. Over the years, many small modifications in ventilators have been incorporated to improve patient outcome. The ventilators of newer generation respond to patient′s demands by additional feedback systems. In this review, we discuss the popular newer modes of ventilation that have been accepted in to clinical practice. Various intensive care units over the world have found these modes to improve patient ventilator synchrony, decrease ventilator days and improve patient safety. The various modes discusses in this review are: Dual control modes (volume assured pressure support, volume support, Adaptive support ventilation, proportional assist ventilation, mandatory minute ventilation, Bi-level airway pressure release ventilation, (BiPAP, neurally adjusted ventilatory assist and NeoGanesh. Their working principles with their advantages and clinical limitations are discussed in brief.

  5. Equivalence in Ventilation and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  6. Low-energy mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Claus Wessel; Hviid, Christian Anker

    2014-01-01

    and with as little energy consumption as 41.1 kWh/m2/year including heating and all building services with no use of renewable energy such as PVcells or solar heating. One of the key means of reaching the objectives was to implement mechanical ventilation with low pressure loss and therefore low energy consumption....... The project consists of two buildings, building one is 6 stories high, and building two is 4 stories high. The buildings have a gross area of 50,500 m2 including underground parking. The ventilation and indoor climate concept was to use mechanical ventilation together with mechanical cooling and fanassisted......, with an average of 1.1 kJ/m3. The yearly mean SFP based on estimated runtime is approx. 0.8 kJ/m3. The case shows the unlocked potential that lies within mechanical ventilation for nearzero energy consuming buildings....

  7. Pulsed ventilation in mines. II

    Energy Technology Data Exchange (ETDEWEB)

    Krause, D

    1975-06-01

    Using test results, an attempt is made to determine the form of the free jet and to derive design data for pulsed fans. The most suitable placing of these fans for the ventilation of headings is discussed.

  8. ENERGY STAR Certified Ventilating Fans

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Ventilating Fans that are effective as of...

  9. Solar chimney: A sustainable approach for ventilation and building space conditioning

    Directory of Open Access Journals (Sweden)

    Lal, S.,

    2013-03-01

    Full Text Available The residential and commercial buildings demand increase with rapidly growing population. It leads to the vertical growth of the buildings and needs proper ventilation and day-lighting. The natural air ventilation system is not significantly works in conventional structure, so fans and air conditioners are mandatory to meet the proper ventilation and space conditioning. Globally building sector consumed largest energy and utmost consumed in heating, ventilation and space conditioning. This load can be reduced by application of solar chimney and integrated approaches in buildings for heating, ventilation and space conditioning. It is a sustainable approach for these applications in buildings. The authors are reviewed the concept, various method of evaluation, modelings and performance of solar chimney variables, applications and integrated approaches.

  10. The Personal Emergency Response System as a Technology Innovation in Primary Health Care Services: An Integrative Review.

    Science.gov (United States)

    Stokke, Randi

    2016-07-14

    Most western countries are experiencing greater pressure on community care services due to increased life expectancy and changes in policy toward prioritizing independent living. This has led to a demand for change and innovation in caring practices with an expected increased use of technology. Despite numerous attempts, it has proven surprisingly difficult to implement and adopt technological innovations. The main established technological innovation in home care services for older people is the personal emergency response system (PERS), which is widely adopted and used throughout most western countries aiming to support "aging safely in place." This integrative review examines how research literature describes use of the PERS focusing on the users' perspective, thus exploring how different actors experience the technology in use and how it affects the complex interactions between multiple actors in caring practices. The review presents an overview of the body of research on this well-established telecare solution, indicating what is important for different actors in regard to accepting and using this technology in community care services. An integrative review, recognized by a systematic search in major databases followed by a review process, was conducted. The search resulted in 33 included studies describing different actors' experiences with the PERS in use. The overall focus was on the end users' experiences and the consequences of having and using the alarm, and how the technology changes caring practices and interactions between the actors. The PERS contributes to safety and independent living for users of the alarm, but there are also unforeseen consequences and possible improvements in the device and the integrated service. This rather simple and well-established telecare technology in use interacts with the actors involved, creating changes in daily living and even affecting their identities. This review argues for an approach to telecare in which the

  11. Personality Development

    Directory of Open Access Journals (Sweden)

    Osman Ozdemir

    2012-12-01

    Full Text Available Personality is the integration of characteristics acquired or brought by birth which separate the individual from others. Personality involves aspects of the individual's mental, emotional, social, and physical features in continuum. Several theories were suggested to explain developmental processes of personality. Each theory concentrates on one feature of human development as the focal point, then integrates with other areas of development in general. Most theories assume that childhood, especially up to 5-6 years, has essential influence on development of personality. The interaction between genetic and environmental factors reveals a unique personality along growth and developmental process. It could be said that individual who does not have any conflict between his/her basic needs and society's, has well-developed and psychologically healthy personality.

  12. Wind Extraction for Natural Ventilation

    Science.gov (United States)

    Fagundes, Tadeu; Yaghoobian, Neda; Kumar, Rajan; Ordonez, Juan

    2017-11-01

    Due to the depletion of energy resources and the environmental impact of pollution and unsustainable energy resources, energy consumption has become one of the main concerns in our rapidly growing world. Natural ventilation, a traditional method to remove anthropogenic and solar heat gains, proved to be a cost-effective, alternative method to mechanical ventilation. However, while natural ventilation is simple in theory, its detailed design can be a challenge, particularly for wind-driven ventilation, which its performance highly involves the buildings' form, surrounding topography, turbulent flow characteristics, and climate. One of the main challenges with wind-driven natural ventilation schemes is due to the turbulent and unpredictable nature of the wind around the building that impose complex pressure loads on the structure. In practice, these challenges have resulted in founding the natural ventilation mainly on buoyancy (rather than the wind), as the primary force. This study is the initial step for investigating the physical principals of wind extraction over building walls and investigating strategies to reduce the dependence of the wind extraction on the incoming flow characteristics and the target building form.

  13. TS LOOP ALCOVE VENTILATION ANALYSIS

    International Nuclear Information System (INIS)

    T.M. Lahnalampi

    2000-01-01

    The scope of this analysis is to examine the existing, constructor installed, physical ventilation installations located in each of the Exploratory Studies Facility (ESF) Topopah Springs (TS) Loop Alcoves No.1, No.2, No.3, No.4, No.6, and No.7. Alcove No.5 is excluded from the scope of this analysis since it is an A/E design system. Each ventilation installation will be analyzed for the purpose of determining if requirements for acceptance into the A/E design technical baseline have been met. The ventilation installations will be evaluated using Occupational Safety and Health Administration (OSHA) standards and Exploratory Studies Facility Design Requirements (ESFDR) (YMP 1997) requirements. The end product will be a technical analysis that will define ventilation installation compliance issues, any outstanding field changes, and use-as-is design deviations that are required to bring the ventilation installations into compliance with requirements for acceptance into the A/E design technical baseline. The analysis will provide guidance for alcove ventilation component design modifications to be developed to correct any deficient components that do not meet minimum requirements and standards

  14. Ventilation Model and Analysis Report

    International Nuclear Information System (INIS)

    Chipman, V.

    2003-01-01

    This model and analysis report develops, validates, and implements a conceptual model for heat transfer in and around a ventilated emplacement drift. This conceptual model includes thermal radiation between the waste package and the drift wall, convection from the waste package and drift wall surfaces into the flowing air, and conduction in the surrounding host rock. These heat transfer processes are coupled and vary both temporally and spatially, so numerical and analytical methods are used to implement the mathematical equations which describe the conceptual model. These numerical and analytical methods predict the transient response of the system, at the drift scale, in terms of spatially varying temperatures and ventilation efficiencies. The ventilation efficiency describes the effectiveness of the ventilation process in removing radionuclide decay heat from the drift environment. An alternative conceptual model is also developed which evaluates the influence of water and water vapor mass transport on the ventilation efficiency. These effects are described using analytical methods which bound the contribution of latent heat to the system, quantify the effects of varying degrees of host rock saturation (and hence host rock thermal conductivity) on the ventilation efficiency, and evaluate the effects of vapor and enhanced vapor diffusion on the host rock thermal conductivity

  15. Mechanical ventilation for severe asthma.

    Science.gov (United States)

    Leatherman, James

    2015-06-01

    Acute exacerbations of asthma can lead to respiratory failure requiring ventilatory assistance. Noninvasive ventilation may prevent the need for endotracheal intubation in selected patients. For patients who are intubated and undergo mechanical ventilation, a strategy that prioritizes avoidance of ventilator-related complications over correction of hypercapnia was first proposed 30 years ago and has become the preferred approach. Excessive pulmonary hyperinflation is a major cause of hypotension and barotrauma. An appreciation of the key determinants of hyperinflation is essential to rational ventilator management. Standard therapy for patients with asthma undergoing mechanical ventilation consists of inhaled bronchodilators, corticosteroids, and drugs used to facilitate controlled hypoventilation. Nonconventional interventions such as heliox, general anesthesia, bronchoscopy, and extracorporeal life support have also been advocated for patients with fulminant asthma but are rarely necessary. Immediate mortality for patients who are mechanically ventilated for acute severe asthma is very low and is often associated with out-of-hospital cardiorespiratory arrest before intubation. However, patients who have been intubated for severe asthma are at increased risk for death from subsequent exacerbations and must be managed accordingly in the outpatient setting.

  16. Argonne Fuel Cycle Facility ventilation system -- modeling and results

    International Nuclear Information System (INIS)

    Mohr, D.; Feldman, E.E.; Danielson, W.F.

    1995-01-01

    This paper describes an integrated study of the Argonne-West Fuel Cycle Facility (FCF) interconnected ventilation systems during various operations. Analyses and test results include first a nominal condition reflecting balanced pressures and flows followed by several infrequent and off-normal scenarios. This effort is the first study of the FCF ventilation systems as an integrated network wherein the hydraulic effects of all major air systems have been analyzed and tested. The FCF building consists of many interconnected regions in which nuclear fuel is handled, transported and reprocessed. The ventilation systems comprise a large number of ducts, fans, dampers, and filters which together must provide clean, properly conditioned air to the worker occupied spaces of the facility while preventing the spread of airborne radioactive materials to clean am-as or the atmosphere. This objective is achieved by keeping the FCF building at a partial vacuum in which the contaminated areas are kept at lower pressures than the other worker occupied spaces. The ventilation systems of FCF and the EBR-II reactor are analyzed as an integrated totality, as demonstrated. We then developed the network model shown in Fig. 2 for the TORAC code. The scope of this study was to assess the measured results from the acceptance/flow balancing testing and to predict the effects of power failures, hatch and door openings, single-failure faulted conditions, EBR-II isolation, and other infrequent operations. The studies show that the FCF ventilation systems am very controllable and remain stable following off-normal events. In addition, the FCF ventilation system complex is essentially immune to reverse flows and spread of contamination to clean areas during normal and off-normal operation

  17. Response of ventilation dampers to large airflow pulses

    International Nuclear Information System (INIS)

    Gregory, W.S.; Smith, P.R.

    1985-04-01

    The results of an experiment program to evaluate the response of ventilation system dampers to simulated tornado transients are reported. Relevant data, such as damper response time, flow rate and pressure drop, and flow/pressure vs blade angle, were obtained, and the response of one tornado protective damper to simulated tornado transients was evaluated. Empirical relationships that will allow the data to be integrated into flow dynamics codes were developed. These flow dynamics codes can be used by safety analysts to predict the response of nuclear facility ventilation systems to tornado depressurization. 3 refs., 21 figs., 6 tabs

  18. Evaluation design of Urban Health Centres Europe (UHCE): Preventive integrated health and social care for community-dwelling older persons in five European cities

    NARCIS (Netherlands)

    Franse, C.B. (Carmen B.); A.J. Voorham; Van Staveren, R. (Rob); E. Koppelaar (Elin); Martijn, R. (Rens); Valía-Cotanda, E. (Elisa); Alhambra-Borrás, T. (Tamara); Rentoumis, T. (Tasos); Bilajac, L. (Lovorka); Marchesi, V.V. (Vanja Vasiljev); Rukavina, T. (Tomislav); Verma, A. (Arpana); Williams, G. (Greg); Clough, G. (Gary); Garcés-Ferrer, J. (Jorge); F.U.S. Mattace Raso (Francesco); H. Raat (Hein)

    2017-01-01

    textabstractBackground: Older persons often have interacting physical and social problems and complex care needs. An integrated care approach in the local context with collaborations between community-, social-, and health-focused organisations can contribute to the promotion of independent living

  19. Evaluation design of Urban Health Centres Europe (UHCE): preventive integrated health and social care for community-dwelling older persons in five European cities

    NARCIS (Netherlands)

    A.J.J. Voorham; R. van Staveren; E. Koppelaar; L.F.J. Martijn; E. Valía-Cotanda; T. Alhambra-Borrás; T. Rentoumis; L. Bilajac; V. Vasiljev Marchesi; T. Rukavina; A. Verma; G. Williams; G. Clough; J. Garcés-Ferrer; F. Mattace Raso; H. Raat; C.B. Franse

    2017-01-01

    Older persons often have interacting physical and social problems and complex care needs. An integrated care approach in the local context with collaborations between community-, social-, and health-focused organisations can contribute to the promotion of independent living and quality of life. In

  20. Ventilation and air-conditioning system for PWR nuclear power plant

    International Nuclear Information System (INIS)

    Ohmoto, Kenji

    1987-01-01

    This report outlines the ventilation and air conditioning facilities for PWR nuclear power plant as well as design re-evaluation and optimization of ventilation and air-conditioning. The primary PWR installations are generally housed in the nuclear reactor building, auxiliary buildings and control building, which are equipped with their own ventilation and air-conditioning systems to serve for their specific purposes. A ventilation/air-conditioning system should be able to work effectively not only for maintaining the ordinary reactor operation but also for controlling the environmental temperature in the event of an accident. Designing of a ventilation/air-conditioning system relied on empirical data in the past, but currently it is performed based on information obtained from various analyses to optimize the system configuration and ventilation capacity. Design re-evaluation of ventilation/air-conditioning systems are conducted widely in various areas, aiming at the integration of safety systems, optimum combination of air-cooling and water-cooling systems, and optimization of the ventilation rate for controlling the concentrations of radioactive substances in the atmosphere in the facilities. It is pointed out that performance evaluation of ventilation/air-conditioning systems, which has been conducted rather macroscopically, should be carried out more in detal in the future to determine optimum air streams and temperature distribution. (Nogami, K.)

  1. Contextualizing ethics: ventilators, H1N1 and marginalized populations.

    Science.gov (United States)

    Silva, Diego S; Nie, Jason X; Rossiter, Kate; Sahni, Sachin; Upshur, Ross E G

    2010-01-01

    If the H1N1 pandemic worsens, there may not be enough ventilated beds to care for all persons with respiratory failure. To date, researchers who explicitly discuss the ethics of intensive care unit admission and the allocation of ventilators during an influenza pandemic have based criteria predominantly on the principles of utility and efficiency, that is, promoting actions that maximize the greatest good for the greatest number of people. However, haphazardly applying utility and efficiency potentially disadvantages marginalized populations who might be at increased risk of severe reactions to H1N1. In Canada, Aboriginals represent 3% of Canadians, yet 11% of H1N1 cases requiring hospitalization involve Aboriginal persons. Aboriginal persons suffer from high rates of obesity due to socio-economic inequalities. Obesity is also a risk factor for severe H1N1 reactions. Yet, since obesity is found to increase the duration of stay in ventilated beds and a long stay is not considered an optimal use of ventilators, applying the principles of utility and efficiency may magnify existing social inequalities. Although promoting utility and efficiency is important, other ethical principles, such as equity and need, require thoughtful consideration and implementation. Furthermore, since public resources are being used to address a public health hazard, the viewpoints of the public, and specifically stakeholders who will be disproportionately affected, should inform decision-makers. Finally, giving attention to the needs and rights of marginalized populations means that ventilators should not be allocated based on criteria that exacerbate the social injustices faced by these groups of people.

  2. Impact of Fire Ventilation on General Ventilation in the Building

    Science.gov (United States)

    Zender-Świercz, Ewa; Telejko, Marek

    2017-10-01

    The fire of building is a threat to its users. The biggest threat is generation, during lifetime of fire, hot gases and smoke. The purpose of quick and efficient evacuation from the area covered by the fire, at first step the escape routes have to be secured from smokiness. The smoke ventilation systems are used for this purpose. The proper design and execution of smoke ventilation is important not only because of the safety, but also of the maintenance of comfort in the building at a time when there is no fire. The manuscript presents the effect of incorrectly realized smoke ventilation in the stairwell of the medium building. The analysis shows that the flaps of smoke ventilation located in the stairwell may have a significant impact on the proper functioning of mechanical ventilation in the period when there is no fire. The improperly installed or incorrect insulated components cause perturbation of air flow and they change pressure distribution in the building. The conclusion of the analysis is the need to include the entire technical equipment of the building during the design and realization of its individual elements. The impact of various installations at each other is very important, and the omission of any of them can cause disturbances in the proper work of another.

  3. The health literacy demands of electronic personal health records (e-PHRs): An integrative review to inform future inclusive research.

    Science.gov (United States)

    Hemsley, Bronwyn; Rollo, Megan; Georgiou, Andrew; Balandin, Susan; Hill, Sophie

    2018-01-01

    To integrate the findings of research on electronic personal health records (e-PHRs) for an understanding of their health literacy demands on both patients and providers. We sought peer-reviewed primary research in English addressing the health literacy demands of e-PHRs that are online and allow patients any degree of control or input to the record. A synthesis of three theoretical models was used to frame the analysis of 24 studies. e-PHRs pose a wide range of health literacy demands on both patients and health service providers. Patient participation in e-PHRs relies not only on their level of education and computer literacy, and attitudes to sharing health information, but also upon their executive function, verbal expression, and understanding of spoken and written language. The multiple health literacy demands of e-PHRs must be considered when implementing population-wide initiatives for storing and sharing health information using these systems. The health literacy demands of e-PHRs are high and could potentially exclude many patients unless strategies are adopted to support their use of these systems. Developing strategies for all patients to meet or reduce the high health literacy demands of e-PHRs will be important in population-wide implementation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Removal of Pharmaceutical and Personal Care Products (PPCPs) from Municipal Waste Water with Integrated Membrane Systems, MBR-RO/NF.

    Science.gov (United States)

    Wang, Yonggang; Wang, Xu; Li, Mingwei; Dong, Jing; Sun, Changhong; Chen, Guanyi

    2018-02-05

    This study focuses on the application of combining membrane bioreactor (MBR) treatment with reverse osmosis (RO) or nanofiltration (NF) membrane treatment for removal of pharmaceuticals and personal care products (PPCPs) in municipal wastewater. Twenty-seven PPCPs were measured in real influent with lowest average concentration being trimethoprim (7.12 ng/L) and the highest being caffeine (18.4 ng/L). The results suggest that the MBR system effectively removes the PPCPs with an efficiency of between 41.08% and 95.41%, and that the integrated membrane systems, MBR-RO/NF, can achieve even higher removal rates of above 95% for most of them. The results also suggest that, due to the differences in removal mechanisms of NF/RO membrane, differences of removal rates exist. In this study, the combination of MBR-NF resulted in the removal of 13 compounds to below detection limits and MBR-RO achieved even better results with removal of 20 compounds to below detection limits.

  5. Contaminants in ventilated filling boxes

    Science.gov (United States)

    Bolster, D. T.; Linden, P. F.

    While energy efficiency is important, the adoption of energy-efficient ventilation systems still requires the provision of acceptable indoor air quality. Many low-energy systems, such as displacement or natural ventilation, rely on temperature stratification within the interior environment, always extracting the warmest air from the top of the room. Understanding buoyancy-driven convection in a confined ventilated space is key to understanding the flow that develops with many of these modern low-energy ventilation schemes. In this work we study the transport of an initially uniformly distributed passive contaminant in a displacement-ventilated space. Representing a heat source as an ideal sourced of buoyancy, analytical and numerical models are developed that allow us to compare the average efficiency of contaminant removal between traditional mixing and modern low-energy systems. A set of small-scale analogue laboratory experiments was also conducted to further validate our analytical and numerical solutions.We find that on average traditional and low-energy ventilation methods are similar with regard to pollutant flushing efficiency. This is because the concentration being extracted from the system at any given time is approximately the same for both systems. However, very different vertical concentration gradients exist. For the low-energy system, a peak in contaminant concentration occurs at the temperature interface that is established within the space. This interface is typically designed to sit at some intermediate height in the space. Since this peak does not coincide with the extraction point, displacement ventilation does not offer the same benefits for pollutant flushing as it does for buoyancy removal.

  6. Integrating Psychopathology and Personality Disorders Conceptualized by the MMPI-2-RF and the MCMI-III: A Structural Validity Study

    NARCIS (Netherlands)

    Heijden, P.T. van der; Egger, J.I.M.; Rossi, G.M.P.; Derksen, J.J.L.

    2012-01-01

    The Minnesota Multiphasic Personality Inventory-2-Restructured Form (Ben-Porath & Tellegen, 2008) Restructured Clinical scales and Higher Order scales were linked to the Millon Clinical Multiaxial Inventory-III ( Millon, Millon, Davis, & Grossman, 2009) personality disorder scales and clinical

  7. The effect of electromagnetic interference from mobile communication on the performance of intensive care ventilators.

    Science.gov (United States)

    Jones, R P; Conway, D H

    2005-08-01

    Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the

  8. Aspiration and the risk of ventilator-associated pneumonia.

    Science.gov (United States)

    Parker, Chris M; Heyland, Daren K

    2004-12-01

    Ventilator-associated pneumonia (VAP) is a major concern in the intensive care unit. It is estimated that the risk of developing VAP may be as high as 1% per ventilated day, and the attributable mortality approaches 50% in some series. A growing body of evidence implicates the role of microaspiration of contaminated oropharyngeal and perhaps gastroesophageal secretions into the airways as an integral step in the pathogenesis of VAP. In patients who have been intubated and mechanically ventilated for >72 hours, the majority of VAP is caused by enteric gram-negative organisms, presumably of gastrointestinal origin. As a result, strategies designed to minimize the risk of these contaminated secretions into the normally sterile airways are of paramount importance in terms of VAP prevention. This review highlights the important etiological role of the gut in the development of VAP and also discusses the evidence behind interventions that may modulate the risk of both aspiration and subsequent VAP.

  9. Trigger performance of mid-level ICU mechanical ventilators during assisted ventilation: a bench study.

    Science.gov (United States)

    Ferreira, Juliana C; Chipman, Daniel W; Kacmarek, Robert M

    2008-09-01

    To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Experimental bench study. The respiratory care laboratory of a university-affiliated teaching hospital. A computerized mechanical lung model, the IngMar ASL5000. Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Performance varied widely among ventilators. Mean inspiratory trigger time was ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

  10. Tidal ventilation distribution during pressure-controlled ventilation and pressure support ventilation in post-cardiac surgery patients.

    Science.gov (United States)

    Blankman, P; VAN DER Kreeft, S M; Gommers, D

    2014-09-01

    Inhomogeneous ventilation is an important contributor to ventilator-induced lung injury. Therefore, this study examines homogeneity of lung ventilation by means of electrical impedance tomography (EIT) measurements during pressure-controlled ventilation (PCV) and pressure support ventilation (PSV) using the same ventilation pressures. Twenty mechanically ventilated patients were studied after cardiac surgery. On arrival at the intensive care unit, ventilation distribution was measured with EIT just above the diaphragm for 15 min. After awakening, PCV was switched to PSV and EIT measurements were again recorded. Tidal impedance variation, a measure of tidal volume, increased during PSV compared with PCV, despite using the same ventilation pressures (P = 0.045). The distribution of tidal ventilation to the dependent lung region was more pronounced during PSV compared with PCV, especially during the first half of the inspiration. An even distribution of tidal ventilation between the dependent and non-dependent lung regions was seen during PCV at lower tidal volumes (tidal volumes (≥ 8 ml/kg). In addition, the distribution of tidal ventilation was predominantly distributed to the dependent lung during PSV at low tidal volumes. In post-cardiac surgery patients, PSV showed improved ventilation of the dependent lung region due to the contribution of the diaphragm activity, which is even more pronounced during lower assist levels. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  12. Air Distribution in a Furnished Room Ventilated by Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, June Richter; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations of the furnit......Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations...

  13. Demand controlled ventilation in a bathroom

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    consumption during periods where the demand for ventilation is low and poor indoor climate during periods where the demand for ventilation is high. Controlling the ventilation rate by demand can improve the energy performance of the ventilation system and the indoor climate. This paper compares the indoor...... climate and energy consumption of a Constant Air Volume (CAV) system and a Demand Controlled Ventilation (DCV) system for two different bathroom designs. The air change rate of the CAV system corresponded to 0.5h-1. The ventilation rate of the DCV system was controlled by occupancy and by the relative...

  14. Airborne radioactive contamination following aerosol ventilation studies

    International Nuclear Information System (INIS)

    Mackie, A.; Hart, G.C.; Ibbett, D.A.; Whitehead, R.J.S.

    1994-01-01

    Lung aerosol ventilation studies may be accompanied by airborne contamination, with subsequent surface contamination. Airborne contamination has been measured prior to, during and following 59 consecutive 99 Tc m -diethylenetriamine pentaacetate (DTPA) aerosol studies using a personal air sampler. Airborne contamination ranging between 0 and 20 330 kBq m -3 has been measured. Airborne contamination increases with degree of patient breathing difficulty. The effective dose equivalent (EDE) to staff from ingested activity has been calculated to be 0.3 μSv per study. This figure is supported by data from gamma camera images of a contaminated staff member. However, surface contamination measurements reveal that 60% of studies exceed maximum permissible contamination limits for the hands; 16% of studies exceed limits for controlled area surfaces. (author)

  15. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

    DEFF Research Database (Denmark)

    Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub

    Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review...... of the existing literature, to establish a link between ventilation rate and key indoor air pollutants. Design characteristics of a mechanical ventilation system such as supply/exhaustairflow, system and design of supply and exhaust outlets were considered. The performance of various ventilation solutionswas......-house ventilation rate was reported below 0.5h-1 or 14 l/s·person in bedrooms, the concentrations of the pollutants elevated above minimum threshold limits (CO2>1350 ppm; TVOC >3000 μg/m3) defined by the standard. Insufficient or non-existent supply of air was related to significantly higher pollutant...

  16. Aromatic hydrocarbons in a controlled ecological life support system during a 4-person-180-day integrated experiment.

    Science.gov (United States)

    Dai, Kun; Yu, Qingni; Zhang, Zhou; Wang, Yuan; Wang, Xinming

    2018-01-01

    Indoor air quality is vital to the health and comfort of people who live inside a controlled ecological life support system (CELSS) built for long-term space explorations. Here we measured aromatic hydrocarbons to assess their sources and health risks during a 4-person-180-day integrated experiment inside a CELSS with four cabins for growing crops, vegetables and fruits and other two cabins for working, accommodations and resources management. During the experiment, the average concentrations of benzene, ethylbenzene, m,p-xylenes and o-xylene were found to decrease exponentially from 7.91±3.72, 37.2±35.2, 100.8±111.7 and 46.8±44.1μg/m 3 to 0.39±0.34, 1.4±0.5, 2.8±0.7 and 2.1±0.9μg/m 3 , with half-lives of 25.3, 44.8, 44.7 and 69.3days, respectively. Toluene to benzene ratios indicated emission from construction materials or furniture to be a dominant source for toluene, and concentrations of toluene fluctuated during the experiment largely due to the changing sorption by growing plants. The cancer and no-cancer risks based on exposure pattern of the crews were insignificant in the end of the experiment. This study also suggested that using low-emitting materials/furniture, growing plants and purifying air actively would all help to lower hazardous air pollutants inside CELSS. Broadly, the results would benefit not only the development of safe and comfort life support systems for space exploration but also the understanding of interactions between human and the total environment in closed systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [Pressure support ventilation and proportional assist ventilation during weaning from mechanical ventilation].

    Science.gov (United States)

    Aguirre-Bermeo, H; Bottiroli, M; Italiano, S; Roche-Campo, F; Santos, J A; Alonso, M; Mancebo, J

    2014-01-01

    To compare tolerance, duration of mechanical ventilation (MV) and clinical outcomes during weaning from MV in patients subjected to either pressure support ventilation (PSV) or proportional assist ventilation (PAV). A prospective, observational study was carried out. Intensive Care Unit. A total of 40 consecutive subjects were allocated to either the PSV or the PAV group until each group contained 20 patients. Patients were included in the study when they met the criteria to begin weaning and the attending physician decided to initiate the weaning process. The physician selected the modality and set the ventilatory parameters. None. Demographic data, respiratory mechanics, ventilatory parameters, duration of MV, and clinical outcomes (reintubation, tracheostomy, mortality). Baseline characteristics were similar in both groups. No significant differences were observed between the PSV and PAV groups in terms of the total duration of MV (10 [5-18] vs. 9 [7-19] days; P=.85), reintubation (5 [31%] vs. 3 [19%]; P=.69), or mortality (4 [20%] vs. 5 [25%] deaths; P=1). Eight patients (40%) in the PSV group and 6 patients (30%) in the PAV group (P=.74) required a return to volume assist-control ventilation due to clinical deterioration. Tolerance, duration of MV and clinical outcomes during weaning from mechanical ventilation were similar in PSV and PAV. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  18. Membrane modules for building ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Kistler, K.R.; Cussler, E.L.

    2002-01-01

    Hollow fibre and flat sheet membranes with an interfacially polymerized coating of polyamide have a permeance for water vapour of about 0.16 m sec{sup -1}. These membranes can serve as a basis for building ventilation which provides fresh air while recovering about 70% of the specific heat and 60% of the latent heat. Because these membranes are selective for water vapour, the air is exhausted with internal pollutants like carbon monoxide, formaldehyde, and radon. The expense of the ventilator should be recovered in reduced heating costs in about three years. (Author)

  19. Limiting volume with modern ventilators.

    Science.gov (United States)

    Wing, Thomas J; Haan, Lutana; Ashworth, Lonny J; Anderson, Jeff

    2015-06-01

    The acute respiratory distress syndrome (ARDS) network low tidal-volume study comparing tidal volumes of 12 ml/kg versus 6 ml/kg was published in 2000. The study was stopped early as data revealed a 22% relative reduction in mortality rate when using 6 ml/kg tidal volume. The current generation of critical care ventilators allows the tidal volume to be set during volume-targeted, assist/control (volume A/C); however, some ventilators include options that may prevent the tidal volume from being controlled. The purpose of this bench study was to evaluate the delivered tidal volume, when these options are active, in a spontaneously breathing lung model using an electronic breathing simulator. Four ventilators were evaluated: CareFusion AVEA (AVEA), Dräger Evita® XL (Evita XL), Covidien Puritan Bennett® 840(TM) (PB 840), and Maquet SERVO-i (SERVO-i). Each ventilator was connected to the Hans Rudolph Electronic Breathing Simulator at an amplitude of 0 cm H2O and then 10 cm H2O. All four ventilators were set to deliver volume A/C, tidal volume 400 ml, respiratory rate 20 bpm, positive end-expiratory pressure 5 cm H2O, peak flowrate 60 L/min. The displayed tidal volume was recorded for each ventilator at the above settings with additional options OFF and then ON. The AVEA has two options in volume A/C: demand breaths and V-sync. When activated, these options allow the patient to exceed the set tidal volume. When using the Evita XL, the option AutoFlow can be turned ON or OFF, and when this option is ON, the tidal volume may vary. The PB 840 does not have any additional options that affect volume delivery, and it maintains the set tidal volume regardless of patient effort. The SERVO-i's demand valve allows additional flow if the patient's inspiratory flowrate exceeds the set flowrate, increasing the delivered tidal volume; this option can be turned OFF with the latest software upgrade. Modern ventilators have an increasing number of optional settings. These settings may

  20. Integration

    DEFF Research Database (Denmark)

    Emerek, Ruth

    2004-01-01

    Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration......Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration...

  1. Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-12-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  2. Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

    Directory of Open Access Journals (Sweden)

    Eduardo Mireles-Cabodevila

    2012-01-01

    Full Text Available Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes. Two examples are adaptive support ventilation (ASV and mid-frequency ventilation (MFV. We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care clinicians provided reference ventilator settings for a 70 kg paralyzed patient in five clinical/physiological scenarios. The survey-derived values for minute ventilation and minute alveolar ventilation were used as goals for ASV and MFV, respectively. A lung simulator programmed with each scenario’s respiratory system characteristics was ventilated using the clinician, ASV, and MFV settings. Results. Tidal volumes ranged from 6.1 to 8.3 mL/kg for the clinician, 6.7 to 11.9 mL/kg for ASV, and 3.5 to 9.9 mL/kg for MFV. Inspiratory pressures were lower for ASV and MFV. Clinician-selected tidal volumes were similar to the ASV settings for all scenarios except for asthma, in which the tidal volumes were larger for ASV and MFV. MFV delivered the same alveolar minute ventilation with higher end expiratory and lower end inspiratory volumes. Conclusions. There are differences and similarities among initial ventilator settings selected by humans and computers for various clinical scenarios. The ventilation outcomes are the result of the lung physiological characteristics and their interaction with the targeting scheme.

  3. Ventilation of radioactive enclosures; Ventilation des enceintes radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Caminade, F; Laurent, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    Mechanical, physical and chemical manipulations on radioactive products must be carried out in properly ventilated enclosed places. The air extracted can only be discharged into the atmosphere after a correct filtration. The power of the ventilation systems is a function of the dimensions and purpose of the enclosure? The choice of types of filter is determined by the physical state and chemical nature of the radioactive materials to be manipulated. This study deals with the individual equipment of small installations: glove boxes, manipulation boxes with outside control and, if necessary, production chambers (maximum useful volume: 5 m{sup 3}). The performances of three types of 'ventilators', and the modifications provided by the addition of filters, are measured and compared. (author) [French] Les manipulations oceaniques, physiques et chimiques sur des produits radioactifs doivent s'effectuer dans des enceintes convenablement ventilees. L'air extrait ne peut etre rejete dans l'atmosphere qu'apres une filtration correcte. La puissance des installations de ventilation est fonction des dimensions de l'enceinte et de son utilisation. Le choix des types de filtres est determine par l'etat physique et la nature ehimique des corps radioactifs manipules. Notre etude porte sur l'equipement individuel d'installations de petites dimensions: boites a gants, boites a pinces et, a la rigueur, enceintes de production (volume maximum utilisable 5 m{sup 3}). Nous mesurons et comparons les performances de trois types de 'ventilateurs' et les modifications apportees par l'adjonction de filtres. (auteur)

  4. Ventilation effectiveness : health benefits of heat recovery ventilators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-08-15

    Studies have shown that the installation of a heat recovery ventilator (HRV) in homes in northern Canada could improve indoor air quality and the respiratory health of inhabitants. Low ventilation rates are common in many homes in the North because the climate is severe, homes are smaller and lack basements, and occupancies are higher, leading to unhealthy indoor air quality. Northern communities also have a high rate of respiratory infections. HRVs recover much of the energy used to ventilate, which is desirable in cold regions with high heating costs. For the study, the test sample was divided into two types of houses, notably houses with active HRVs and those with control HRVs that were installed and operated but that did not function. The study results showed that HRVs provided increased ventilation. Complaints by residents about HRV noise, discomfort, or low humidity were common but equally spread between those with active and placebo HRVs. The study showed that the system design needs to be improved to better suit the needs of Inuit families. The nature of northern housing presents installation and maintenance challenges. It is hard to retrofit HRV ducting inside small, existing houses, and building supplies arrive infrequently, so detailed planning and careful take-offs of all supplies and materials must be done well in advance of construction. In addition, contractors are hard to locate and have variable expertise, and there is little technical follow-up. Robust technical support by local contractors and housing authorities is therefore important. 2 refs.

  5. INTEGRATING THE TRANSACTIONAL ANALYSIS AS AN ASSESSMENT TECHNIQUE TO THETRIANGLE OF PERSONALITY, JOB SATISFACTION AND ORGANIZATIONAL COMMITMENT

    OpenAIRE

    Canan Muter Şengül

    2015-01-01

    A successful job environment is believed to be created when individual interestsare put aside forthe sake of obtaining mutual benefits. At this point, providing jobsatisfaction and organizational commitment is essential. The present research isconducted through thehypothesis that personality predicts these two factors andthen seeks to reveal this effect.Big Five Personality Model and TransactionalAnalysis are used for evaluatingthe personality factor.The...

  6. Decisional responsibility for mechanical ventilation and weaning

    DEFF Research Database (Denmark)

    Rose, Louise; Blackwood, Bronagh; Egerod, Ingrid

    2011-01-01

    Optimal management of mechanical ventilation and weaning requires dynamic and collaborative decision making to minimize complications and avoid delays in the transition to extubation. In the absence of collaboration, ventilation decision making may be fragmented, inconsistent, and delayed. Our...

  7. Perioperative lung protective ventilation in obese patients

    NARCIS (Netherlands)

    Fernandez-Bustamante, Ana; Hashimoto, Soshi; Serpa Neto, Ary; Moine, Pierre; Vidal Melo, Marcos F.; Repine, John E.

    2015-01-01

    The perioperative use and relevance of protective ventilation in surgical patients is being increasingly recognized. Obesity poses particular challenges to adequate mechanical ventilation in addition to surgical constraints, primarily by restricted lung mechanics due to excessive adiposity, frequent

  8. The School Advanced Ventilation Engineering Software (SAVES)

    Science.gov (United States)

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  9. Improvements of uranium mine ventilation system

    International Nuclear Information System (INIS)

    Liu Changrong; Zhou Xinghuo; Liu Zehua; Wang Zhiyong

    2007-01-01

    Ventilation has been proved to be a main method to eliminate radon and its daughters in uranium mines. According to the practical rectifications of uranium mine ventilation system, the improved measures are summarized. (authors)

  10. C-106 tank process ventilation test

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air filter and housing to the recirculation system. This configuration would eventually become the possible cause of exceptions. During the performance of the test, there were points where the equipment did not function per the directions listed in the ATP. These events fell into several different categories. The first and easiest problems were field configurations that did not match the design documentation. This was corrected by modifying the field configuration to meet design documentation and reperforming the applicable sections of the ATP. A second type of problem encountered was associated with equipment which did not operate correctly, at which point an exception was written against the ATP, to be resolved later. A third type of problem was with equipment that actually operated correctly but the directions in the ATP were in error. These were corrected by generating an Engineering Change Notice (ECN) against the ATP. The ATP with corrected directions was then re-performed. A fourth type of problem was where the directions in the ATP were as the equipment should operate, but the design of

  11. The salience network and human personality: Integrity of white matter tracts within anterior and posterior salience network relates to the self-directedness character trait.

    Science.gov (United States)

    Prillwitz, Conrad; Rüber, Theodor; Reuter, Martin; Montag, Christian; Weber, Bernd; Elger, Christian E; Markett, Sebastian

    2018-04-28

    A prevailing topic in personality neuroscience is the question how personality traits are reflected in the brain. Functional and structural networks have been examined by functional and structural magnetic resonance imaging, however, the structural correlates of functionally defined networks have not been investigated in a personality context. By using the Temperament and Character Inventory (TCI) and Diffusion Tensor Imaging (DTI), the present study assesses in a sample of 116 healthy participants how personality traits proposed in the framework of the biopsychosocial theory on personality relate to white matter pathways delineated by functional network imaging. We show that the character trait self-directedness relates to the overall microstructural integrity of white matter tracts constituting the salience network as indicated by DTI-derived measures. Self-directedness has been proposed as the executive control component of personality and describes the tendency to stay focused on the attainment of long-term goals. The present finding corroborates the view of the salience network as an executive control network that serves maintenance of rules and task-sets to guide ongoing behavior. Copyright © 2018. Published by Elsevier B.V.

  12. Ventilation area measured with eit in order to optimize peep settings in mechanically ventilated patients

    NARCIS (Netherlands)

    Blankman, P; Groot Jebbink, E; Preis, C; Bikker, I.; Gommers, D.

    2012-01-01

    INTRODUCTION. Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which can be used to visualize ventilation. Ventilation will be measured by impedance changes due to ventilation. OBJECTIVES. The aim of this study was to optimize PEEP settings based on the ventilation area of

  13. Initial ventilator settings for critically ill patients

    OpenAIRE

    Kilickaya, Oguz; Gajic, Ognjen

    2013-01-01

    The lung-protective mechanical ventilation strategy has been standard practice for management of acute respiratory distress syndrome (ARDS) for more than a decade. Observational data, small randomized studies and two recent systematic reviews suggest that lung protective ventilation is both safe and potentially beneficial in patients who do not have ARDS at the onset of mechanical ventilation. Principles of lung-protective ventilation include: a) prevention of volutrauma (tidal volume 4 to 8 ...

  14. Building ventilation, state of the art, prospective

    International Nuclear Information System (INIS)

    1995-10-01

    This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, radon decontamination, thermal comfort and acoustic levels in buildings

  15. Artificial humidification for the mechanically ventilated patient

    OpenAIRE

    Selvaraj, Nelson

    2010-01-01

    Caring for patients who are mechanically ventilated poses many\\ud challenges for critical care nurses. It is important to humidify the\\ud patient’s airways artificially to prevent complications such as\\ud ventilator-associated pneumonia. There is no gold standard to\\ud determine which type of humidification is best for patients who\\ud are artificially ventilated. This article provides an overview of\\ud commonly used artificial humidification for mechanically ventilated\\ud patients and discuss...

  16. Artificial humidification for the mechanically ventilated patient.

    Science.gov (United States)

    Selvaraj, N

    Caring for patients who are mechanically ventilated poses many challenges for critical care nurses. It is important to humidify the patient's airways artificially to prevent complications such as ventilator-associated pneumonia. There is no gold standard to determine which type of humidification is best for patients who are artificially ventilated. This article provides an overview of commonly used artificial humidification for mechanically ventilated patients and discusses nurses' responsibilities in caring for patients receiving artificial humidification.

  17. High-Frequency Percussive Ventilation Revisited

    Science.gov (United States)

    2010-01-01

    be implemented. ‡ Follow the reverse of the ventilation sequence if respiratory alkalosis develops—however, start at ventilation goal sequence 1 not at...High-frequency percussive ventilation (HFPV) has demonstrated a potential role as a rescue option for refractory acute respiratory distress syndrome...frequency percussive ventilation (HFPV) has demon- strated a potential role as a salvage option for refrac- tory acute respiratory distress syndrome

  18. Performance comparison of 15 transport ventilators.

    Science.gov (United States)

    Chipman, Daniel W; Caramez, Maria P; Miyoshi, Eriko; Kratohvil, Joseph P; Kacmarek, Robert M

    2007-06-01

    Numerous mechanical ventilators are designed and marketed for use in patient transport. The complexity of these ventilators differs considerably, but very few data exist to compare their operational capabilities. Using bench and animal models, we studied 15 currently available transport ventilators with regard to their physical characteristics, gas consumption (duration of an E-size oxygen cylinder), battery life, ease of use, need for compressed gas, ability to deliver set ventilation parameters to a test lung under 3 test conditions, and ability to maintain ventilation and oxygenation in normal and lung-injured sheep. Most of the ventilators tested were relatively simple to operate and had clearly marked controls. Oxygen cylinder duration ranged from 30 min to 77 min. Battery life ranged from 70 min to 8 hours. All except 3 of the ventilators were capable of providing various F(IO2) values. Ten of the ventilators had high-pressure and patient-disconnect alarms. Only 6 of the ventilators were able to deliver all settings as specifically set on the ventilator during the bench evaluation. Only 4 of the ventilators were capable of maintaining ventilation, oxygenation, and hemodynamics in both the normal and the lung-injured sheep. Only 2 of the ventilators met all the trial targets in all the bench and animal tests. With many of the ventilators, certain of the set ventilation parameters were inaccurate (differed by > 10% from the values from a cardiopulmonary monitor). The physical characteristics and high gas consumption of some of these ventilators may render them less desirable for patient transport.

  19. Implementation of natural ventilation in pig houses

    NARCIS (Netherlands)

    Klooster, van 't C.E.

    1994-01-01

    A description of experimental work and discussion on implementation of natural ventilation in pig houses is given. A literature review describes the state of the art, animal growth data are given. It includes characterization of ventilation openings, a technique to estimate the ventilation

  20. 46 CFR 98.25-75 - Ventilation.

    Science.gov (United States)

    2010-10-01

    ... shall be fitted with efficient natural or mechanical ventilation. (b) Enclosed compartments in which... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation. 98.25-75 Section 98.25-75 Shipping COAST... Ventilation. (a) All enclosed spaces containing cargo tanks fitted with bottom outlet connections shall be...