WorldWideScience

Sample records for integrated light dose

  1. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  2. Integral dose conservation in radiotherapy

    International Nuclear Information System (INIS)

    Reese, Adam S.; Das, Shiva K.; Curle, Charles; Marks, Lawrence B.

    2009-01-01

    Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

  3. Daily light integral and day light quality: Potentials and pitfalls of nighttime UV treatments on cucumber powdery mildew.

    Science.gov (United States)

    Suthaparan, Aruppillai; Solhaug, Knut Asbjørn; Stensvand, Arne; Gislerød, Hans Ragnar

    2017-10-01

    Nighttime ultraviolet (UV) radiation, if applied properly, has a significant potential for management of powdery mildews in many crop species. In this study, the role of growth light duration, irradiance, a combination of both (daily light integral) and light spectral quality (blue or red) on the efficacy of UV treatments against powdery mildew caused by Podosphaera xanthii and the growth performance of cucumber plants was studied in growth chambers. Increasing daily light integral provided by high-pressure sodium lamps (HPS) decreased efficacy of nighttime UV treatments against P. xanthii, but it increased plant growth. Furthermore, the efficacy of nighttime UV decreased when day length was increased from 16 to 20h at a constant daily light integral. The efficacy of nighttime UV increased if red light was applied after UV treatment, showing the possibility of day length extension without reducing the effect of UV. Increasing the dose of blue light during daytime reduced the efficacy of nighttime UV in controlling the disease, whereas blue deficient growth light (light after nighttime UV reduced its disease control efficacy. This showed the importance of maintaining a minimum of blue light in the growth light before nighttime UV treatment. Findings from this study showed that optimization of nighttime UV for management of powdery mildew is dependent on the spectral composition of the photosynthetically active radiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Green Lighting. Energy-efficient integrated lighting systems - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Linhart, F.; Scartezzini, J.-L.

    2009-10-15

    The objective of the Green Lighting project was to develop a High Performance Integrated Lighting System, based on advanced technologies for day- and electric lighting, achieving a Lighting Power Density (LPD) that does not exceed 3 W/m{sup 2}. The project has revealed that Anidolic Daylighting Systems (ADS) are an ideal basis for High Performance Integrated Lighting Systems. Not only are they able to provide adequate illumination (i.e. sufficiently high illuminance) in office rooms during large fractions of normal office hours, under various sky conditions and over the entire year, but they are also highly appreciated by office occupants at the condition that glare control mechanisms are available. Complementary electric lighting is, however, still necessary to back up the ADS at times when there is insufficient daylight flux available. It was shown during this project, that the most interesting trade-offs between energy-efficiency and visual comfort are obtained by using a combination of ceiling-mounted directly emitting luminaires with very high optical efficiencies for ambient lighting and portable desk lamps for temporary task lighting. The most appropriate lamps for the ceiling-mounted luminaires are currently highly efficient fluorescent tubes, but white LED tubes can be considered a realistic option for the future. The most suitable light sources for desk lamps for temporary task lighting are Compact Fluorescent Lamps (CFLs) and white LED light bulbs. Based on the above-mentioned technologies, a High Performance Integrated Lighting System with a very low LPD has been developed over the last three years. The system has been set up in an office room of the LESO solar experimental building located on the EPFL campus; it has been tested intensively during a Post-Occupancy Evaluation (POE) study involving twenty human subjects. This study has revealed that the subjects' performance and subjective visual comfort was improved by the new system, compared to

  5. Integrated Photonics Enabled by Slow Light

    DEFF Research Database (Denmark)

    Mørk, Jesper; Chen, Yuntian; Ek, Sara

    2012-01-01

    In this talk we will discuss the physics of slow light in semiconductor materials and in particular the possibilities offered for integrated photonics. This includes ultra-compact slow light enabled optical amplifiers, lasers and pulse sources.......In this talk we will discuss the physics of slow light in semiconductor materials and in particular the possibilities offered for integrated photonics. This includes ultra-compact slow light enabled optical amplifiers, lasers and pulse sources....

  6. Efficient in vitro photodynamic inactivation of Candida albicans by repetitive light doses

    Science.gov (United States)

    Torres-Hurtado, S. A.; Ramírez Ramírez, J.; Ramos-García, R.; Ramírez-San-Juan, J. C.; Spezzia-Mazzocco, T.

    2018-02-01

    The aim of this study was to compare the effectiveness of Rose Bengal (RB) and Methylene Blue (MB) as photosensitizers (PS) in Photodynamic Inactivation (PDI) on planktonic cultures of Candida albicans, a well-known opportunistic pathogen. RB and MB at concentrations ranging from 0.5 to 60 μM and fluences of 10, 30, 45 and 60 J/cm2 were tested. The light sources consist of an array of 12 led diodes with 30 mW of optical power each; 490-540 nm (green light) to activate RB and 600 -650 nm (red light) to activate MB. We first optimize the in vitro PDI technique using a single light dose and the optimum PS concentration. The novelty of our approach consist in reducing further the PS concentration than the optimum obtained with a single light exposure and using smaller light fluence doses by using repetitive light exposures (two to three times). MB and RB were tested for repetitive exposures at concentrations ranging from 0.1 to 10 μM, with fluences of 3 to 20 J/cm2, doses well below than those reported previously. All experiments were done in triplicate with the corresponding controls; cells without treatment, light control and dark toxicity control. RB-PDI and MB-PDI significantly reduced the number of CFU/mL when compared to the control groups. The results showed that RB was more effective than MB for C. albicans inactivation. Thus, we show that is possible to reduce significantly the amount of PS and light fluence requirements using repetitive light doses of PDI in vitro.

  7. Comparison of three light doses in the photodynamic treatment of actinic keratosis using mathematical modeling

    Science.gov (United States)

    Vignion-Dewalle, Anne-Sophie; Betrouni, Nacim; Tylcz, Jean-Baptiste; Vermandel, Maximilien; Mortier, Laurent; Mordon, Serge

    2015-05-01

    Photodynamic therapy (PDT) is an emerging treatment modality for various diseases, especially for cancer therapy. Although high efficacy is demonstrated for PDT using standardized protocols in nonhyperkeratotic actinic keratoses, alternative light doses expected to increase efficiency, to reduce adverse effects or to expand the use of PDT, are still being evaluated and refined. We propose a comparison of the three most common light doses in the treatment of actinic keratosis with 5-aminolevulinic acid PDT through mathematical modeling. The proposed model is based on an iterative procedure that involves determination of the local fluence rate, updating of the local optical properties, and estimation of the local damage induced by the therapy. This model was applied on a simplified skin sample model including an actinic keratosis lesion, with three different light doses (red light dose, 37 J/cm2, 75 mW/cm2, 500 s blue light dose, 10 J/cm2, 10 mW/cm2, 1000 s and daylight dose, 9000 s). Results analysis shows that the three studied light doses, although all efficient, lead to variable local damage. Defining reference damage enables the nonoptimal parameters for the current light doses to be refined and the treatment to be more suitable.

  8. Integrated Plastic Substrates for OLED Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Gaynor, Whitney

    2015-08-01

    OLED lighting has immense potential as aesthetically pleasing, energy-efficient general illumination. Unlike other light sources, such as incandescents, fluorescents, and inorganic LEDs, OLEDs naturally emit over a large-area surface. They are glare free, do not need to be shaded, and are cool to the touch, requiring no heatsink. The best efficiencies and lifetimes reported are on par with or better than current forms of illumination. However, the cost for OLED lighting remains high – so much so that these products are not market competitive and there is very low consumer demand. We believe that flexible, plastic-based devices will highlight the advantages of aesthetically-pleasing OLED lighting systems while paving the way for lowering both materials and manufacturing costs. These flexible devices require new development in substrate and support technology, which was the focus of the work reported here. The project team, led by Sinovia Technologies, has developed integrated plastic substrates to serve as supports for flexible OLED lighting. The substrates created in this project would enable large-area, flexible devices and are specified to perform three functions. They include a barrier to protect the OLED from moisture and oxygen-related degradation, a smooth, highly conductive transparent electrode to enable large-area device operation, and a light scattering layer to improve emission efficiency. Through the course of this project, integrated substrates were fabricated, characterized, evaluated for manufacturing feasibility and cost, and used in white OLED demonstrations to test their impact on flexible OLED lighting. Our integrated substrates meet or exceed the DOE specifications for barrier performance in water vapor and oxygen transport rates, as well as the transparency and conductivity of the anode film. We find that these integrated substrates can be manufactured in a completely roll-to-roll, high throughput process and have developed and demonstrated

  9. Integral dose and evaluation of irradiated tissue volume

    International Nuclear Information System (INIS)

    Sivachenko, T.P.; Kalina, V.K.; Belous, A.K.; Gaevskij, V.I.

    1984-01-01

    Two parameters having potentialities of radiotherapy planning improvement are under consideration. One of these two parameters in an integral dose. An efficiency of application of special tables for integral dose estimation is noted. These tables were developed by the Kiev Physician Improvement Institute and the Cybernetics Institute of the Ukrainian SSR Academy of Science. The meaning of the term of ''irradiated tissue volume'' is specified, and the method of calculation of the irradiated tissue effective mass is considered. It is possible to evaluate with higher accuracy tolerance doses taking into account the irradiated mass

  10. A tunable lighting system integrated by inorganic and transparent organic light-emitting diodes

    Science.gov (United States)

    Zhang, Jing-jing; Zhang, Tao; Jin, Ya-fang; Liu, Shi-shen; Yuan, Shi-dong; Cui, Zhao; Zhang, Li; Wang, Wei-hui

    2014-05-01

    A tunable surface-emitting integrated lighting system is constructed using a combination of inorganic light-emitting diodes (LEDs) and transparent organic LEDs (OLEDs). An RB two-color LED is used to supply red and blue light emission, and a green organic LED is used to supply green light emission. Currents of the LED and OLED are tuned to produce a white color, showing different Commission Internationale d'Eclairage (CIE) chromaticity coordinates and correlated color temperatures with a wide adjustable range. Such an integration can compensate for the lack of the LED's luminance uniformity and the transparent OLED's luminance intensity.

  11. Integral dose investigation of non-coplanar treatment beam geometries in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dan; Dong, Peng; Ruan, Dan; Low, Daniel A.; Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States); Long, Troy; Romeijn, Edwin [Department of Industrial and Operations, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-01-15

    Purpose: Automated planning and delivery of non-coplanar plans such as 4π radiotherapy involving a large number of fields have been developed to take advantage of the newly available automated couch and gantry on C-arm gantry linacs. However, there is an increasing concern regarding the potential changes in the integral dose that needs to be investigated. Methods: A digital torso phantom and 22 lung and liver stereotactic body radiation therapy (SBRT) patients were included in the study. The digital phantom was constructed as a water equivalent elliptical cylinder with a major axis length of 35.4 cm and minor axis of 23.6 cm. A 4.5 cm diameter target was positioned at varying depths along the major axis. Integral doses from intensity modulated, non-coplanar beams forming a conical pattern were compared against the equally spaced coplanar beam plans. Integral dose dependence on the phantom geometry and the beam number was also quantified. For the patient plans, the non-coplanar and coplanar beams and fluences were optimized using a column generation and pricing approach and compared against clinical VMAT plans using two full (lung) or partial coplanar arcs (liver) entering at the side proximal to the tumor. Both the average dose to the normal tissue volume and the total volumes receiving greater than 2 Gy (V2) and 5 Gy (V5) were evaluated and compared. Results: The ratio of integral dose from the non-coplanar and coplanar plans depended on the tumor depth for the phantom; for tumors shallower than 10 cm, the non-coplanar integral doses were lower than coplanar integral doses for non-coplanar angles less than 60°. Similar patterns were observed in the patient plans. The smallest non-coplanar integral doses were observed for tumor 6–8 cm deep. For the phantom, the integral dose was independent of the number of beams, consistent with the liver SBRT patients but the lung SBRT patients showed slight increase in the integral dose when more beams were used. Larger

  12. Prescriptionless light-cone integrals

    International Nuclear Information System (INIS)

    Suzuki, A.T.; Schmidt, A.G.M.

    2000-01-01

    Perturbative quantum gauge field theory as seen within the perspective of physical gauge choices such as the light-cone gauge entails the emergence of troublesome poles of the type (k.n) -α in the Feynman integrals. These come from the boson field propagator, where α=1,2,.. and n μ is the external arbitrary four-vector that defines the gauge properly. This becomes an additional hurdle in the computation of Feynman diagrams, since any graph containing internal boson lines will inevitably produce integrands with denominators bearing the characteristic gauge-fixing factor. How one deals with them has been the subject of research over decades, and several prescriptions have been suggested and tried in the course of time, with failures and successes. However, a more recent development at this fronteer which applies the negative dimensional technique to compute light-cone Feynman integrals shows that we can altogether dispense with prescriptions to perform the calculations. An additional bonus comes to us attached to this new technique, in that not only it renders the light-cone prescriptionless but, by the very nature of it, it can also dispense with decomposition formulas or partial fractioning tricks used in the standard approach to separate pole products of the type (k.n) -α [(k-p).n] -β (β=1,2,..). In this work we demonstrate how all this can be done. (orig.)

  13. Analysis of Electronic Densities and Integrated Doses in Multiform Glioblastomas Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Baron-Aznar, C.; Moreno-Jimenez, S.; Celis, M. A.; Ballesteros-Zebadua, P.; Larraga-Gutierrez, J. M.

    2008-01-01

    Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed

  14. Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection

    Energy Technology Data Exchange (ETDEWEB)

    Ruehm, Werner [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Neuherberg (Germany); Woloschak, Gayle E. [Northwestern University, Department of Radiation Oncology, Feinberg School of Medicine, Chicago, IL (United States); Shore, Roy E. [Radiation Effects Research Foundation (RERF), Hiroshima City (Japan); Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Grosche, Bernd [Federal Office for Radiation Protection, Oberschleissheim (Germany); Niwa, Ohtsura [Fukushima Medical University, Fukushima (Japan); Akiba, Suminori [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Epidemiology and Preventive Medicine, Kagoshima City (Japan); Ono, Tetsuya [Institute for Environmental Sciences, Rokkasho, Aomori-ken (Japan); Suzuki, Keiji [Nagasaki University, Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki (Japan); Iwasaki, Toshiyasu [Central Research Institute of Electric Power Industry (CRIEPI), Radiation Safety Research Center, Nuclear Technology Research Laboratory, Tokyo (Japan); Ban, Nobuhiko [Tokyo Healthcare University, Faculty of Nursing, Tokyo (Japan); Kai, Michiaki [Oita University of Nursing and Health Sciences, Department of Environmental Health Science, Oita (Japan); Clement, Christopher H.; Hamada, Nobuyuki [International Commission on Radiological Protection (ICRP), PO Box 1046, Ottawa, ON (Canada); Bouffler, Simon [Public Health England (PHE), Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot (United Kingdom); Toma, Hideki [JAPAN NUS Co., Ltd. (JANUS), Tokyo (Japan)

    2015-11-15

    The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so-called dose and dose-rate effectiveness factor (DDREF). The present paper summarizes what was presented and discussed by experts from ICRP and Japan at a dedicated workshop on this topic held in May 2015 in Kyoto, Japan. This paper describes the historical development of the DDREF concept in light of emerging scientific evidence on dose and dose-rate effects, summarizes the conclusions recently drawn by a number of international organizations (e.g., BEIR VII, ICRP, SSK, UNSCEAR, and WHO), mentions current scientific efforts to obtain more data on low-dose and low-dose-rate effects at molecular, cellular, animal and human levels, and discusses future options that could be useful to improve and optimize the DDREF concept for the purpose of radiological protection. (orig.)

  15. Integrated light in direct excitation and energy transfer luminescence

    OpenAIRE

    Chimczak, Eugeniusz

    2007-01-01

    Integrated light in direct excitation and energy transfer luminescence has been investigated. In the investigations reported here, monomolecular centers were taken into account. It was found that the integrated light is equal to the product of generation rate and time of duration of excitation pulse for both direct excitation and energy transfer luminescence.

  16. Timing growth and development of Campanula by daily light integral and supplemental light level in a cost-efficient light control system

    DEFF Research Database (Denmark)

    Kjær, Katrine Heinsvig; Ottosen, Carl-Otto; Jørgensen, Bo Nørregaard

    2012-01-01

    light control system (DynaLight desktop) automatically defines the most cost-efficient use of supplemental light based on predefined setpoints for daily photosynthesis integral (DPI), forecasted solar irradiance and the market price on electricity. It saves energy in high-cost periods of electricity......Two campanula species Campanula portenschlagiana (‘Blue Get Mee’) and Campanula cochlearifolia (‘Blue Wonder’) were grown in a cost-efficient light control system and the effect of supplemental light level and daily light integral (DLI) on growth and development was quantified. The alternative...... the number of flowers and buds and CLI in ‘Blue Get Mee’. The results demonstrate that DLI was the main limiting factor for prediction of growth and development when two campanula species were grown in a cost-efficient light control system where the number of daily light hours was often below the critical...

  17. Si light-emitting device in integrated photonic CMOS ICs

    Science.gov (United States)

    Xu, Kaikai; Snyman, Lukas W.; Aharoni, Herzl

    2017-07-01

    The motivation for integrated Si optoelectronics is the creation of low-cost photonics for mass-market applications. Especially, the growing demand for sensitive biochemical sensors in the environmental control or medicine leads to the development of integrated high resolution sensors. Here CMOS-compatible Si light-emitting device structures are presented for investigating the effect of various depletion layer profiles and defect engineering on the photonic transition in the 1.4-2.8 eV. A novel Si device is proposed to realize both a two-terminal Si-diode light-emitting device and a three-terminal Si gate-controlled diode light-emitting device in the same device structure. In addition to the spectral analysis, differences between two-terminal and three-terminal devices are discussed, showing the light emission efficiency change. The proposed Si optical source may find potential applications in micro-photonic systems and micro-optoelectro-mechanical systems (MOEMS) in CMOS integrated circuitry.

  18. A chlorophyll fluorescence-based method for the integrated characterization of the photophysiological response to light stress.

    Science.gov (United States)

    Serôdio, João; Schmidt, William; Frankenbach, Silja

    2017-02-01

    This work introduces a new experimental method for the comprehensive description of the physiological responses to light of photosynthetic organisms. It allows the integration in a single experiment of the main established manipulative chlorophyll fluorescence-based protocols. It enables the integrated characterization of the photophysiology of samples regarding photoacclimation state (generating non-sequential light-response curves of effective PSII quantum yield, electron transport rate or non-photochemical quenching), photoprotection capacity (running light stress-recovery experiments, quantifying non-photochemical quenching components) and the operation of photoinactivation and photorepair processes (measuring rate constants of photoinactivation and repair for different light levels and the relative quantum yield of photoinactivation). The new method is based on a previously introduced technique, combining the illumination of a set of replicated samples with spatially separated actinic light beams of different intensity, and the simultaneous measurement of the fluorescence emitted by all samples using an imaging fluorometer. The main novelty described here is the independent manipulation of light intensity and duration of exposure for each sample, and the control of the cumulative light dose applied. The results demonstrate the proof of concept for the method, by comparing the responses of cultures of Chlorella vulgaris acclimated to low and high light regimes, highlighting the mapping of light stress responses over a wide range of light intensity and exposure conditions, and the rapid generation of paired light-response curves of photoinactivation and repair rate constants. This approach represents a chlorophyll fluorescence 'protocol of everything', contributing towards the high throughput characterization of the photophysiology of photosynthetic organisms. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental

  19. Determination of the integral dose in CT of the neurocranium

    Energy Technology Data Exchange (ETDEWEB)

    Rahim, H.; Mandl, H.; Hofmann, W.; Grobovschek, M.

    1985-12-01

    The amount of exposure of the cranium is calculated on the basis of the measured dose distribution in craniocaudal direction and on the axial planes of the Alderson phantom. The integral dose of the cranium and the local dose at sensitive organs are used as a measure of radiation exposure. (orig.).

  20. Continuous background light significantly increases flashing-light enhancement of photosynthesis and growth of microalgae.

    Science.gov (United States)

    Abu-Ghosh, Said; Fixler, Dror; Dubinsky, Zvy; Iluz, David

    2015-01-01

    Under specific conditions, flashing light enhances the photosynthesis rate in comparison to continuous illumination. Here we show that a combination of flashing light and continuous background light with the same integrated photon dose as continuous or flashing light alone can be used to significantly enhance photosynthesis and increase microalgae growth. To test this hypothesis, the green microalga Dunaliella salina was exposed to three different light regimes: continuous light, flashing light, and concomitant application of both. Algal growth was compared under three different integrated light quantities; low, intermediate, and moderately high. Under the combined light regime, there was a substantial increase in all algal growth parameters, with an enhanced photosynthesis rate, within 3days. Our strategy demonstrates a hitherto undescribed significant increase in photosynthesis and algal growth rates, which is beyond the increase by flashing light alone. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Disparity in Cutaneous Pigmentary Response to LED vs Halogen Incandescent Visible Light: Results from a Single Center, Investigational Clinical Trial Determining a Minimal Pigmentary Visible Light Dose.

    Science.gov (United States)

    Soleymani, Teo; Cohen, David E; Folan, Lorcan M; Okereke, Uchenna R; Elbuluk, Nada; Soter, Nicholas A

    2017-11-01

    Background: While most of the attention regarding skin pigmentation has focused on the effects of ultraviolet radiation, the cutaneous effects of visible light (400 to 700nm) are rarely reported. The purpose of this study was to investigate the cutaneous pigmentary response to pure visible light irradiation, examine the difference in response to different sources of visible light irradiation, and determine a minimal pigmentary dose of visible light irradiation in melanocompetent subjects with Fitzpatrick skin type III - VI. The study was designed as a single arm, non-blinded, split-side dual intervention study in which subjects underwent visible light irradiation using LED and halogen incandescent light sources delivered at a fluence of 0.14 Watts/cm2 with incremental dose progression from 20 J/cm2 to 320 J/cm2. Pigmentation was assessed by clinical examination, cross-polarized digital photography, and analytic colorimetry. Immediate, dose-responsive pigment darkening was seen with LED light exposure in 80% of subjects, beginning at 60 Joules. No pigmentary changes were seen with halogen incandescent light exposure at any dose in any subject. This study is the first to report a distinct difference in cutaneous pigmentary response to different sources of visible light, and the first to demonstrate cutaneous pigment darkening from visible LED light exposure. Our findings raise the concern that our increasing daily artificial light surroundings may have clandestine effects on skin biology. J Drugs Dermatol. 2017;16(11):1105-1110..

  2. Bright-light intervention induces a dose-dependent increase in striatal response to risk in healthy volunteers

    DEFF Research Database (Denmark)

    Macoveanu, Julian; Fisher, Patrick M; Madsen, Martin K

    2016-01-01

    Bright-light interventions have successfully been used to reduce depression symptoms in patients with seasonal affective disorder, a depressive disorder most frequently occurring during seasons with reduced daylight availability. Yet, little is known about how light exposure impacts human brain...... function, for instance on risk taking, a process affected in depressive disorders. Here we examined the modulatory effects of bright-light exposure on brain activity during a risk-taking task. Thirty-two healthy male volunteers living in the greater Copenhagen area received 3weeks of bright......-light intervention during the winter season. Adopting a double-blinded dose-response design, bright-light was applied for 30minutes continuously every morning. The individual dose varied between 100 and 11.000lx. Whole-brain functional MRI was performed before and after bright-light intervention to probe how...

  3. On-chip synthesis of circularly polarized emission of light with integrated photonic circuits.

    Science.gov (United States)

    He, Li; Li, Mo

    2014-05-01

    The helicity of circularly polarized (CP) light plays an important role in the light-matter interaction in magnetic and quantum material systems. Exploiting CP light in integrated photonic circuits could lead to on-chip integration of novel optical helicity-dependent devices for applications ranging from spintronics to quantum optics. In this Letter, we demonstrate a silicon photonic circuit coupled with a 2D grating emitter operating at a telecom wavelength to synthesize vertically emitting, CP light from a quasi-TE waveguide mode. Handedness of the emitted circular polarized light can be thermally controlled with an integrated microheater. The compact device footprint enables a small beam diameter, which is desirable for large-scale integration.

  4. [Determination of the integral dose in computer tomography of the neurocranium].

    Science.gov (United States)

    Rahim, H; Hofmann, W; Grobovschek, M; Mandl, H

    1985-12-01

    The amount of exposure of the cranium is calculated on the basis of the measured dose distribution in craniocaudal direction and on the axial planes of the Alderson phantom. The integral dose of the cranium and the local dose at sensitive organs are used as a measure of radiation exposure.

  5. Digital Drug Dosing: Dosing in Drug Assays by Light-Defined Volumes of Hydrogels with Embedded Drug-Loaded Nanoparticles

    DEFF Research Database (Denmark)

    Faralli, Adele; Melander, Fredrik; Larsen, Esben Kjær Unmack

    2014-01-01

    Polyethylene glycol (PEG)-based hydrogels are widely used for biomedical applications, including matrices for controlled drug release. We present a method for defining drug dosing in screening assays by light-activated cross-linking of PEG-diacrylate hydrogels with embedded drug-loaded liposome...

  6. High-Voltage LED Light Engine with Integrated Driver

    Energy Technology Data Exchange (ETDEWEB)

    Soer, Wouter [Lumileds LLC, San Jose, CA (United States)

    2016-02-29

    LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-power LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm2), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm2 and 4 mm2) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux

  7. III-nitride Photonic Integrated Circuit: Multi-section GaN Laser Diodes for Smart Lighting and Visible Light Communication

    KAUST Repository

    Shen, Chao

    2017-04-01

    The past decade witnessed the rapid development of III-nitride light-emitting diodes (LEDs) and laser diodes (LDs), for smart lighting, visible-light communication (VLC), optical storage, and internet-of-things. Recent studies suggested that the GaN-based LDs, which is free from efficiency droop, outperform LEDs as a viable high-power light source. Conventionally, the InGaN-based LDs are grown on polar, c-plane GaN substrates. However, a relatively low differential gain limited the device performance due to a significant polarization field in the active region. Therefore, the LDs grown on nonpolar m-plane and semipolar (2021)-plane GaN substrates are posed to deliver high-efficiency owing to the entirely or partially eliminated polarization field. To date, the smart lighting and VLC functionalities have been demonstrated based on discrete devices, such as LDs, transverse-transmission modulators, and waveguide photodetectors. The integration of III-nitride photonic components, including the light emitter, modulator, absorber, amplifier, and photodetector, towards the realization of III-nitride photonic integrated circuit (PIC) offers the advantages of small-footprint, high-speed, and low power consumption, which has yet to be investigated. This dissertation presents the design, fabrication, and characterization of the multi-section InGaN laser diodes with integrated functionalities on semipolar (2021)-plane GaN substrates for enabling such photonic integration. The blue-emitting integrated waveguide modulator-laser diode (IWM-LD) exhibits a high modulation efficiency of 2.68 dB/V. A large extinction ratio of 11.3 dB is measured in the violet-emitting IWM-LD. Utilizing an integrated absorber, a high optical power (250mW), droop-free, speckle-free, and large modulation bandwidth (560MHz) blue-emitting superluminescent diode is reported. An integrated short-wavelength semiconductor optical amplifier with the laser diode at ~404 nm is demonstrated with a large gain of 5

  8. Effect of low-dose gamma irradiation on storage properties in light salted Pseudosciaena crocea

    International Nuclear Information System (INIS)

    Zhang Xiaoyan; Yang Xianshi; Li Xueying; Guo Quanyou

    2012-01-01

    To explore the preservation effect of γ irradiation on light salted Pseudosciaena crocea, the influence of 1 kGy low-dose γ irradiation on sensory quality, microbiological and chemical quality including TVC, TVB-N and TBARS contents of light salted P. crocea stored at 25 ℃ was discussed. The results showed that the number of total viable counts significantly decreased after irradiation, during the whole storage, the bacteria numbers of light salted P. crocea treated with irradiation were still less than the control. The concentrations of TVB-N was significantly reduced after irradiation, whereas lipid oxidation was less accelerated. The shelf life could be remarkably prolonged after low-dose γ irradiation. While the shelf life of control group were 9 and 11 days, the shelf life of irradiated light salted P. crocea were extended to 16 and 20 days, respectively. The results can provide technical references for commercial application of seafood irradiation. (authors)

  9. SU-F-J-56: The Connection Between Cherenkov Light Emission and Radiation Absorbed Dose in Proton Irradiated Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Kassaee, A; Finlay, J [University of Pennsylvania, Philadelphia, PA (United States); Taleei, R [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Range verification in proton therapy is of great importance. Cherenkov light follows the photon and electron energy deposition in water phantom. The purpose of this study is to investigate the connection between Cherenkov light generation and radiation absorbed dose in a water phantom irradiated with proton beams. Methods: Monte Carlo simulation was performed by employing FLUKA Monte Carlo code to stochastically simulate radiation transport, ionizing radiation dose deposition, and Cherenkov radiation in water phantoms. The simulations were performed for proton beams with energies in the range 50–600 MeV to cover a wide range of proton energies. Results: The mechanism of Cherenkov light production depends on the initial energy of protons. For proton energy with 50–400 MeV energy that is below the threshold (∼483 MeV in water) for Cherenkov light production directly from incident protons, Cherenkov light is produced mainly from the secondary electrons liberated as a result of columbic interactions with the incident protons. For proton beams with energy above 500 MeV, in the initial depth that incident protons have higher energy than the Cherenkov light production threshold, the light has higher intensity. As the slowing down process results in lower energy protons in larger depths in the water phantom, there is a knee point in the Cherenkov light curve vs. depth due to switching the Cherenkov light production mechanism from primary protons to secondary electrons. At the end of the depth dose curve the Cherenkov light intensity does not follow the dose peak because of the lack of high energy protons to produce Cherenkov light either directly or through secondary electrons. Conclusion: In contrast to photon and electron beams, Cherenkov light generation induced by proton beams does not follow the proton energy deposition specially close to the end of the proton range near the Bragg peak.

  10. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  11. Total site integration of light hydrocarbons separation process

    OpenAIRE

    Ulyev, L.; Vasilyev, M.; Maatouk, A.; Duic, Neven; Khusanovc, Alisher

    2016-01-01

    Ukraine is the largest consumer of hydrocarbons per unit of production in Europe (Ukraine policy review, 2006). The most important point is a reduction of energy consumption in chemical and metallurgical industries as a biggest consumer. This paper deals with energy savings potential of light hydrocarbons separation process. Energy consumption of light hydrocarbons separation process processes typical of Eastern European countries were analysed. Process Integration (PI) was used to perform a ...

  12. DITTY - a computer program for calculating population dose integrated over ten thousand years

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.

    1986-03-01

    The computer program DITTY (Dose Integrated Over Ten Thousand Years) was developed to determine the collective dose from long term nuclear waste disposal sites resulting from the ground-water pathways. DITTY estimates the time integral of collective dose over a ten-thousand-year period for time-variant radionuclide releases to surface waters, wells, or the atmosphere. This document includes the following information on DITTY: a description of the mathematical models, program designs, data file requirements, input preparation, output interpretations, sample problems, and program-generated diagnostic messages

  13. Integration method of 3D MR spectroscopy into treatment planning system for glioblastoma IMRT dose painting with integrated simultaneous boost

    International Nuclear Information System (INIS)

    Ken, Soléakhéna; Cassol, Emmanuelle; Delannes, Martine; Celsis, Pierre; Cohen-Jonathan, Elizabeth Moyal; Laprie, Anne; Vieillevigne, Laure; Franceries, Xavier; Simon, Luc; Supper, Caroline; Lotterie, Jean-Albert; Filleron, Thomas; Lubrano, Vincent; Berry, Isabelle

    2013-01-01

    To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT). For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 60-Gy plan in IMRT and one 72-Gy plan in SIB-IMRT. All sixteen MRSI metabolic maps were integrated into TPS, using normalization with color-space conversion and threshold-based segmentation. The fusion between the metabolic maps and the planning CT scans were assessed. Dosimetry comparisons were performed between the different plans of 60-Gy 3D-CRT, 60-Gy IMRT and 72-Gy SIB-IMRT, the last plan was targeted on MRSI abnormalities and contrast enhancement (CE). Fusion assessment was performed for 160 transformations. It resulted in maximum differences <1.00 mm for translation parameters and ≤1.15° for rotation. Dosimetry plans of 72-Gy SIB-IMRT and 60-Gy IMRT showed a significantly decreased maximum dose to the brainstem (44.00 and 44.30 vs. 57.01 Gy) and decreased high dose-volumes to normal brain (19 and 20 vs. 23% and 7 and 7 vs. 12%) compared to 60-Gy 3D-CRT (p < 0.05). Delivering standard doses to conventional target and higher doses to new target volumes characterized by MRSI and CE is now possible and does not increase dose to organs at risk. MRSI and CE abnormalities are now integrated for glioblastoma SIB-IMRT, concomitant with temozolomide, in an ongoing multi-institutional phase-III clinical trial. Our method of MR spectroscopy maps integration to TPS is robust and reliable; integration to neuronavigation systems with this method could also improve glioblastoma resection or guide biopsies

  14. Data integration reveals key homeostatic mechanisms following low dose radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Tilton, Susan C.; Matzke, Melissa M. [Computational Biology and Bioinformatics, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Sowa, Marianne B.; Stenoien, David L.; Weber, Thomas J. [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Morgan, William F. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99338 (United States); Waters, Katrina M., E-mail: katrina.waters@pnnl.gov [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99338 (United States)

    2015-05-15

    The goal of this study was to define pathways regulated by low dose radiation to understand how biological systems respond to subtle perturbations in their environment and prioritize pathways for human health assessment. Using an in vitro 3-D human full thickness skin model, we have examined the temporal response of dermal and epidermal layers to 10 cGy X-ray using transcriptomic, proteomic, phosphoproteomic and metabolomic platforms. Bioinformatics analysis of each dataset independently revealed potential signaling mechanisms affected by low dose radiation, and integrating data shed additional insight into the mechanisms regulating low dose responses in human tissue. We examined direct interactions among datasets (top down approach) and defined several hubs as significant regulators, including transcription factors (YY1, MYC and CREB1), kinases (CDK2, PLK1) and a protease (MMP2). These data indicate a shift in response across time — with an increase in DNA repair, tissue remodeling and repression of cell proliferation acutely (24–72 h). Pathway-based integration (bottom up approach) identified common molecular and pathway responses to low dose radiation, including oxidative stress, nitric oxide signaling and transcriptional regulation through the SP1 factor that would not have been identified by the individual data sets. Significant regulation of key downstream metabolites of nitrative stress was measured within these pathways. Among the features identified in our study, the regulation of MMP2 and SP1 was experimentally validated. Our results demonstrate the advantage of data integration to broadly define the pathways and networks that represent the mechanisms by which complex biological systems respond to perturbation. - Highlights: • Low dose ionizing radiation altered homeostasis in 3D skin tissue model. • Global gene/protein/metabolite data integrated using complementary statistical approaches • Time and location-specific change in matrix regulation

  15. Curcumin uptake enhancement using low dose light illumination during incubation in Candida albicans

    Science.gov (United States)

    Romano, Renan A.; Pratavieira, Sebastião.; da Silva, Ana P.; Kurachi, Cristina; Bagnato, Vanderlei S.; Guimarães, Francisco E. G.

    2017-07-01

    A new PDI protocol is presented in this study. C. albicans cells pre-illuminated with a low dose light demonstrated an increase of curcumin uptake when compared to dark incubation, leading to a higher PDI efficacy.

  16. Three-Week Bright-Light Intervention Has Dose-Related Effects on Threat-Related Corticolimbic Reactivity and Functional Coupling

    DEFF Research Database (Denmark)

    Fisher, Patrick M; Madsen, Martin K; Mc Mahon, Brenda

    2014-01-01

    environmental stimuli (e.g., threat) and may underlie these effects. Serotonin signaling modulates this circuit and is implicated in the pathophysiology of seasonal and other affective disorders. METHODS: We evaluated the effects of a bright-light intervention protocol on threat-related corticolimbic reactivity......-related amygdala and prefrontal reactivity in a dose-dependent manner. Conversely, amygdala-prefrontal and intraprefrontal functional coupling increased significantly in a dose-dependent manner. Genotype status significantly moderated bright-light intervention effects on intraprefrontal functional coupling....... CONCLUSIONS: This is the first study to evaluate the effects of clinically relevant bright-light intervention on threat-related brain function. We show that amygdala-prefrontal reactivity and communication are significantly affected by bright-light intervention, an effect partly moderated by genotype...

  17. The effect of source-axis distance on integral dose: implications for IMRT

    International Nuclear Information System (INIS)

    Keall, P.

    2001-01-01

    The source-axis distance (SAD) is a treatment machine design parameter that affects integral dose, dose rate and patient clearance. The aim of this work was to investigate the effect of source-axis distance on integral dose for conformal arc therapy. This work is part of a larger project to determine the ideal characteristics of a dedicated IMRT machine. The sensitivity of SAD to beam energy, PTV size, body size and PTV position were determined for conformal arc therapy. For the calculations performed here it was assumed that dose equals terma. The integral dose ratio (IDR) was used to quantify the calculation results. It was found that the IDR increases as both SAD and photon energy increase, though the dependence of IDR on SAD decreases as energy increases. The PTV size was found to have a negligible effect on the relationship between the SAD and IDR, however the body size does affect the relationship between the SAD and IDR. The position of the PTV within the body also affects the IDR. From dosimetric considerations alone, the larger the SAD, the better the possible dose distribution. The IDR for a very large SAD is increased by approximately 5% when compared with the IDR for 100 cm SAD. Similarly, the IDR for 100 cm SAD is approximately 5% higher than the IDR at 50 cm SAD. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  18. The dependence of dose recovery experiments on the bleaching of natural quartz OSL using different light sources

    International Nuclear Information System (INIS)

    Choi, J.H.; Murray, A.S.; Cheong, C.-S.; Hong, S.C.

    2009-01-01

    In this paper, the dependence of dose recovery tests on the different bleaching light sources (blue-LEDs, solar simulator, natural sunlight) is investigated with a variety of sedimentary quartz samples, selected so that their OSL signals are dominated by the fast OSL component. We observed that when long solar simulator bleaching was applied, various known doses were underestimated in an SAR-based dose recovery test. However, when blue-LEDs and short solar simulator bleaching were used (10 s and 60 s) the known doses were accurately recovered. In repeated measurement of the OSL signals induced by the same regeneration and test dose, we observed a considerable increase in quartz OSL sensitivity during or after the first OSL measurement when long solar simulator bleaching was used; this seems to provide a possible explanation for the observed underestimation of the laboratory known doses. A series of experimental results using a sample from a modern aeolian dune surface shows that there are no subsequent sensitivity changes when the naturally zeroed samples are bleached with sunlight for long time. It seems that there is a dependence of the sensitivity change on the amount of dose administered before solar simulator bleaching and on the light intensity of solar simulator. When small doses were given to the naturally zeroed sample, the sensitivity change during or after the first OSL measurement was not significant. However, when a considerable amount of beta dose (∼4000 Gy) is administered to the sample, a clear sensitivity change during or after the first OSL measurement (∼20%) was observed. Such a sensitivity change was not observed when the bleaching light intensity of solar simulator was reduced by increasing the distance between samples and the UV lamp. Our results show that, at least for the samples described here, the outcomes of dose recovery experiments are dependent on the bleaching conditions.

  19. 2ω Dimensional light-cone integrals with momentum shift

    International Nuclear Information System (INIS)

    Suzuki, A.T.

    1987-01-01

    A class of light-cone integrals typical to one-loop calculations in the two-component formalism is considered. One finds type of integrals in the evaluation of one-loop diagrams, such as the 'swordfish' diagrams. The results cannot be expressed as a finite sum of elementary functions, but convergence is verified for the particular cases considered. (G.D.F.) [pt

  20. Job-related doses in light water reactors

    International Nuclear Information System (INIS)

    Schnuer, K.

    1993-01-01

    The Treaty of 1957 establishing the European Atomic Energy Community, (EURATOM) was an essential prerequisite for the development of a strong nuclear industry in Europe. Among other things the Treaty provides that the Community shall lay down Basic Safety Standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiation and ensure that they are applied. Following adoption of the Council Directive of 1980, the European Commission defined the basic principles of Justification, Optimization and Limitation to be applied in order to ensure the greatest possible protection of workers and the general public. Subsequently the Commission took initiatives in order to find ways of implementing these three basic principles in practical radiation protection. In 1980 the Commission in close collaboration with the leading nuclear power station operators, set up its own system of 'occupational radiation dose statistics from light water reactors operating in Western Europe'. This was designed for PWRs and BWRs, and the Commission benefited from the experience of neighbouring non-EC countries such as Sweden, Finland, Switzerland and Spain (not yet a member) operating nuclear power stations made by different manufacturers. The paper provides some general information on developments and trends in collective and individual doses to workers in nuclear power stations, based on a unique European databank of approximately 1000 operating reactor years. 9 figs

  1. Integration of models for the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Napier, B.A.

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at Hanford since 1944. The objective of phase 1 of the project was to demonstrate through calculations that adequate models and support data exist or could be developed to allow realistic estimations of doses to individuals from releases of radionuclides to the environment that occurred as long as 45 years ago. Much of the data used in phase 1 was preliminary; therefore, the doses calculated must be considered preliminary approximations. This paper describes the integration of various models that was implemented for initial computer calculations. Models were required for estimating the quantity of radioactive material released, for evaluating its transport through the environment, for estimating human exposure, and for evaluating resultant doses

  2. Detailed abundances from integrated-light spectroscopy: Milky Way globular clusters

    Science.gov (United States)

    Larsen, S. S.; Brodie, J. P.; Strader, J.

    2017-05-01

    Context. Integrated-light spectroscopy at high spectral resolution is rapidly maturing as a powerful way to measure detailed chemical abundances for extragalactic globular clusters (GCs). Aims: We test the performance of our analysis technique for integrated-light spectra by applying it to seven well-studied Galactic GCs that span a wide range of metallicities. Methods: Integrated-light spectra were obtained by scanning the slit of the UVES spectrograph on the ESO Very Large Telescope across the half-light diameters of the clusters. We modelled the spectra using resolved Hubble Space Telescope colour-magnitude diagrams (CMDs), as well as theoretical isochrones, in combination with standard stellar atmosphere and spectral synthesis codes. The abundances of Fe, Na, Mg, Ca, Ti, Cr, and Ba were compared with literature data for individual stars in the clusters. Results: The typical differences between iron abundances derived from our integrated-light spectra and those compiled from the literature are less than 0.1 dex. A larger difference is found for one cluster (NGC 6752), and is most likely caused primarily by stochastic fluctuations in the numbers of bright red giants within the scanned area. As expected, the α-elements (Ca, Ti) are enhanced by about 0.3 dex compared to the Solar-scaled composition, while the [Cr/Fe] ratios are close to Solar. When using up-to-date line lists, our [Mg/Fe] ratios also agree well with literature data. Our [Na/Fe] ratios are, on average, 0.08-0.14 dex lower than average values quoted in the literature, and our [Ba/Fe] ratios may be overestimated by 0.20-0.35 dex at the lowest metallicities. We find that analyses based on theoretical isochrones give very similar results to those based on resolved CMDs. Conclusions: Overall, the agreement between our integrated-light abundance measurements and the literature data is satisfactory. Refinements of the modelling procedure, such as corrections for stellar evolutionary and non-LTE effects

  3. Dose determination with nitro blue tetrazolium containing radiochromic dye films by measuring absorbed and reflected light

    DEFF Research Database (Denmark)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.

    2000-01-01

    determination in a wide dose range both by absorbance and reflectance measurements. The concept of measuring reflected light from dose labels has been discussed earlier and emerged recently due to the requirement of introducing semiquantitative label dose indicators for quarantine control. The usefulness...... of the method was studied using the newly developed radiochromic dye films as well as already existing ones. (C) 2000 Elsevier Science Ltd. All rights reserved....

  4. AMIC: an expandable integrated analog front-end for light distribution moments analysis

    OpenAIRE

    SPAGGIARI, MICHELE; Herrero Bosch, Vicente; Lerche, Christoph Werner; Aliaga Varea, Ramón José; Monzó Ferrer, José María; Gadea Gironés, Rafael

    2011-01-01

    In this article we introduce AMIC (Analog Moments Integrated Circuit), a novel analog Application Specific Integrated Circuit (ASIC) front-end for Positron Emission Tomography (PET) applications. Its working principle is based on mathematical analysis of light distribution through moments calculation. Each moment provides useful information about light distribution, such as energy, position, depth of interaction, skewness (deformation due to border effect) etc. A current buffer delivers a cop...

  5. Lighting control and dimensioning in integrated daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Halonen, L.; Eloholma, M.; Lehtovaara, J.

    1996-12-31

    The objective of this research was to find out the subjective and individual requirements for lighting control in connection with daylight utilization in indoor lighting. There is a great potential to use daylight in indoor lighting. This sets demands for the integrated daylight control systems, so that the indoor lighting can be optimized and demands of the users can be fulfilled. Control strategies should also take into account individual light needs, luminance balance and visual comfort. New lighting control systems and strategies such as vertical/horizontal illuminance ratio were studied. The incoming daylight may radically change the luminance distribution of the visual field and the effects of daylight on luminances of vertical surfaces may become especially noticeable. When daylight is utilized in indoor lighting, special care has to be taken to maintain the quality of the lighting of the visual environment. The windows become a potential source of discomfort glare in offices in uncontrolled daylight conditions. With the present methods it is not possible to evaluate discomfort glare caused by high surface luminances or windows. The results of this research do not support the opinion that low vision people in offices need more light than the normally sighted or that the illumination levels should be raised for low vision people. The rise of lighting levels from the present practice (task illuminance level 500 lux) in office work does not improve the visual performance of low vision people. In planning the visual environment for the low vision people care has to be taken on the direction of light. (7 refs.)

  6. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  7. Energy savings due to daylight and artificial lighting integration in office buildings in hot climate

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ashwal, Nagib T. [Sana' a University, Sana' a (Yemen); Budaiwi, Ismail M. [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2011-07-01

    Reducing energy consumption while maintaining acceptable environmental quality in buildings has been a challenging task for building professionals. In office buildings, artificial lighting systems are a major consumer of energy and can significantly contribute to building cooling load. Furthermore, although reliable, artificial lighting does not necessarily provide the required quality of lighting. Significant improvement in lighting quality and energy consumption can be achieved by proper integration of daylight and artificial lighting. The objective of this study is to investigate the energy performance of office buildings resulting from daylight and artificial lighting integration in hot climates. A parametric analysis is conducted to find the impact of different window design parameters, including window area, height and glazing type, on building energy performance. Results have shown that as much as 35% reduction in lighting energy consumption and 13% reduction in total energy consumption can be obtained when proper daylighting and artificial lighting integration is achieved.

  8. Risk of a second malignant neoplasm after cancer in childhood treated with radiotherapy: correlation with the integral dose

    International Nuclear Information System (INIS)

    Nguyen, F.; Rubino, C.; Guerin, S.; de Vathaire, F.; Diallo, I.; Samand, A.; Hawkins, M.; Oberlin, O.; Lefkopoulos, D.

    2006-01-01

    In the cohort, among patients who had received radiotherapy, only those who had received the highest integral dose had a higher risk. Among the other patients, including 80% of the variability of the integral dose, no increased risk was evidenced. Thus, the integral dose in the study cannot be considered as a good predictor of later risk. (N.C.)

  9. Risk of a second malignant neoplasm after cancer in childhood treated with radiotherapy: correlation with the integral dose

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, F.; Rubino, C.; Guerin, S.; de Vathaire, F. [National Institute of Public Health and Medical Research (INSERM) Unit 605, Institut Gustave-Roussy, Villejuif (France); Diallo, I.; Samand, A. [National Institute of Public Health and Medical Research (INSERM) Unit 605, Institut Gustave-Roussy, Villejuif, (France); Medical Physics and Radiotherapy Departments, Institut Gustave-Roussy, Villejuif (France); Hawkins, M. [Centre for Childhood Cancer Survivor Studies, University of Birmingham, Birmingham (United Kingdom); Oberlin, O. [Paediatrics Department, Institut Gustave-Roussy, Villejuif (France); Lefkopoulos, D. [Medical Physics and Radiotherapy Departments, Institut Gustave-Roussy, Villejuif (France)

    2006-07-01

    In the cohort, among patients who had received radiotherapy, only those who had received the highest integral dose had a higher risk. Among the other patients, including 80% of the variability of the integral dose, no increased risk was evidenced. Thus, the integral dose in the study cannot be considered as a good predictor of later risk. (N.C.)

  10. Quantifying the radiant exposure and effective dose in patients treated for actinic keratoses with topical photodynamic therapy using daylight and LED white light

    Science.gov (United States)

    Manley, M.; Collins, P.; Gray, L.; O'Gorman, S.; McCavana, J.

    2018-02-01

    Daylight photodynamic therapy (dl-PDT) is as effective as conventional PDT (c-PDT) for treating actinic keratoses but has the advantage of reducing patient discomfort significantly. Topical dl-PDT and white light-PDT (wl-PDT) differ from c-PDT by way of light sources and methodology. We measured the variables associated with light dose delivery to skin surface and influence of geometry using a radiometer, a spectral radiometer and an illuminance meter. The associated errors of the measurement methods were assessed. The spectral and spatial distribution of the radiant energy from the LED white light source was evaluated in order to define the maximum treatment area, setup and treatment protocol for wl-PDT. We compared the data with two red LED light sources we use for c-PDT. The calculated effective light dose is the product of the normalised absorption spectrum of the photosensitizer, protoporphyrin IX (PpIX), the irradiance spectrum and the treatment time. The effective light dose from daylight ranged from 3  ±  0.4 to 44  ±  6 J cm-2due to varying weather conditions. The effective light dose for wl-PDT was reproducible for treatments but it varied across the treatment area between 4  ±  0.1 J cm-2 at the edge and 9  ±  0.1 J cm-2 centrally. The effective light dose for the red waveband (615-645 nm) was 0.42  ±  0.05 J cm-2 on a clear day, 0.05  ±  0.01 J cm-2 on an overcast day and 0.9  ±  0.01 J cm-2 using the white light. This compares with 0.95  ±  0.01 and 0.84  ±  0.01 J cm-2 for c-PDT devices. Estimated errors associated with indirect determination of daylight effective light dose were very significant, particularly for effective light doses less than 5 J cm-2 (up to 83% for irradiance calculations). The primary source of error is in establishment of the relationship between irradiance or illuminance and effective dose. Use of the O’Mahoney model is recommended using a

  11. An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin

    2015-01-01

    An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between...... abstract and blurred phenomena, these diffused luminous reflections rouse us into interactions with the world. In this book we are interested in identifying the qualitative parameters involved in the integration of dynamic artificial lighting and daylight; the latter being already highly dynamic by nature...... that examine how the dynamic artificial lighting in the observational instrument unfolds during the changing of the daylight situations that are generated by the weather outside. This research employs the concept of coupling between interior and exterior, in order to identify a spectrum of design parameters...

  12. Interstitial near-infrared photoimmunotherapy: effective treatment areas and light doses needed for use with fiber optic diffusers.

    Science.gov (United States)

    Okuyama, Shuhei; Nagaya, Tadanobu; Sato, Kazuhide; Ogata, Fusa; Maruoka, Yasuhiro; Choyke, Peter L; Kobayashi, Hisataka

    2018-02-16

    Near-infrared photoimmunotherapy (NIR-PIT), a promising cancer therapy utilizing an antibody-photoabsorber conjugate (APC) and NIR light, which induces rapid necrotic cell death only in APC-bound cells. Effective NIR-PIT in mouse models has been achieved using superficial light illumination (SLI) with light emitting diodes (LEDs) or lasers, but in the clinical setting, fiber optic diffusers have been employed to deliver light to deeper tumors. However, the performance of NIR light in tissue delivered by fiber optic diffusers is poorly understood. Here, we investigated NIR-PIT using a cylindrical fiber optic diffuser in a mouse model of A431 tumors. NIR-PIT with 100 J/cm, the same light dose used in clinical trials of NIR-PIT, was applied after insertion of the diffuser within the tumor bed, and then both bioluminescence and fluorescence imaging were analyzed to assess the therapeutic efficacy. The diffuser can deliver adequate NIR light dose for effective NIR-PIT to the A431 tumor at a distance of approximately 1 cm around the light source at 100 J/cm. At 50 J/cm NIR light effective NIR-PIT was reduced to a distance of 5 - 7 mm diameter around the light source. These results indicate that the energy of interstitial light (measured in Joules/cm) administered via a fiber diffuser determines the depth of effective NIR-PIT around the diffuser and determines the spacing at which such diffusers should be placed to entirely cover the tumor. Thermal measurements demonstrate that interstitial light for NIR-PIT does not cause damage to the skin overlying the diffuser.

  13. Integration of a high-NA light microscope in a scanning electron microscope.

    Science.gov (United States)

    Zonnevylle, A C; Van Tol, R F C; Liv, N; Narvaez, A C; Effting, A P J; Kruit, P; Hoogenboom, J P

    2013-10-01

    We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  14. Time-integrated thyroid dose for accidental releases from Pakistan Research Reactor-1

    International Nuclear Information System (INIS)

    Raza, S Shoaib; Iqbal, M; Salahuddin, A; Avila, R; Pervez, S

    2004-01-01

    The two-hourly time-integrated thyroid dose due to radio-iodines released to the atmosphere through the exhaust stack of Pakistan Research Reactor-1 (PARR-1), under accident conditions, has been calculated. A computer program, PAKRAD (which was developed under an IAEA research grant, PAK/RCA/8990), was used for the dose calculations. The sensitivity of the dose results to different exhaust flow rates and atmospheric stability classes was studied. The effect of assuming a constant activity concentration (as a function of time) within the containment air volume and an exponentially decreasing air concentration on the time-integrated dose was also studied for various flow rates (1000-50,000 m 3 h -1 ). The comparison indicated that the results were insensitive to the containment air exhaust rates up to or below 2000 m 3 h -1 , when the prediction with the constant activity concentration assumption was compared to an exponentially decreasing activity concentration model. The results also indicated that the plume touchdown distance increases with increasing atmospheric stability. (note)

  15. Computer Modeling of Daylight-Integrated Photocontrol of Electric Lighting Systems

    Directory of Open Access Journals (Sweden)

    Richard Mistrick

    2015-05-01

    Full Text Available This article presents a variety of different approaches to both model and assess the performance of daylight-integrated electric lighting control systems. In these systems, the output of a controlled lighting zone is based on a light sensor reading and a calibrated control algorithm. Computer simulations can consider the simulated illuminance data generated from both the electric lighting system and a daylight delivery system whose performance is addressed using typical meteorological year (TMY weather data. Photosensor signals and the operation of a control system’s dimming algorithms are also included. Methods and metrics for evaluating simulated performance for the purpose of making informed design decisions that lead to the best possible installed system performance are presented.

  16. High Efficiency Lighting with Integrated Adaptive Control (HELIAC), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project is the continued development of the High Efficiency Lighting with Integrated Adaptive Control (HELIAC) system. Solar radiation is not a viable...

  17. High Efficiency Lighting with Integrated Adaptive Control (HELIAC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation of the proposed project is the development of High Efficiency Lighting with Integrated Adaptive Control (HELIAC) systems to drive plant growth. Solar...

  18. A CMOS microdisplay with integrated controller utilizing improved silicon hot carrier luminescent light sources

    Science.gov (United States)

    Venter, Petrus J.; Alberts, Antonie C.; du Plessis, Monuko; Joubert, Trudi-Heleen; Goosen, Marius E.; Janse van Rensburg, Christo; Rademeyer, Pieter; Fauré, Nicolaas M.

    2013-03-01

    Microdisplay technology, the miniaturization and integration of small displays for various applications, is predominantly based on OLED and LCoS technologies. Silicon light emission from hot carrier electroluminescence has been shown to emit light visibly perceptible without the aid of any additional intensification, although the electrical to optical conversion efficiency is not as high as the technologies mentioned above. For some applications, this drawback may be traded off against the major cost advantage and superior integration opportunities offered by CMOS microdisplays using integrated silicon light sources. This work introduces an improved version of our previously published microdisplay by making use of new efficiency enhanced CMOS light emitting structures and an increased display resolution. Silicon hot carrier luminescence is often created when reverse biased pn-junctions enter the breakdown regime where impact ionization results in carrier transport across the junction. Avalanche breakdown is typically unwanted in modern CMOS processes. Design rules and process design are generally tailored to prevent breakdown, while the voltages associated with breakdown are too high to directly interact with the rest of the CMOS standard library. This work shows that it is possible to lower the operating voltage of CMOS light sources without compromising the optical output power. This results in more efficient light sources with improved interaction with other standard library components. This work proves that it is possible to create a reasonably high resolution microdisplay while integrating the active matrix controller and drivers on the same integrated circuit die without additional modifications, in a standard CMOS process.

  19. A Conceptual Framework for Integration of Evidence-Based Design with Lighting Simulation Tools

    Directory of Open Access Journals (Sweden)

    Anahita Davoodi

    2017-09-01

    Full Text Available The use of lighting simulation tools has been growing over the past years which has improved lighting analysis. While computer simulations have proven to be a viable tool for analyzing lighting in physical environments, they have difficulty in assessing the effects of light on occupant’s perception. Evidence-based design (EBD is a design method that is gaining traction in building design due to its strength in providing means to assess the effects of built environments on humans. The aim of this study was to develop a conceptual framework for integrating EBD with lighting simulation tools. Based on a literature review, it was investigated how EBD and lighting simulation can be combined to provide a holistic lighting performance evaluation method. The results show that they can mutually benefit from each other. EBD makes it possible to evaluate and/or improve performance metrics by utilizing user feedback. On the other hand, performance metrics can be used for a better description of evidence, and to analyze the effects of lighting with more details. The results also show that EBD can be used to evaluate light simulations to better understand when and how they should be performed. A framework is presented for integration of lighting simulation and EBD.

  20. Efficacy of integrated treatment of UV light and low dose gamma irradiation on Escherichia coli O157:H7 and Salmonella enterica on grape tomatoes

    Science.gov (United States)

    Efficacy of integrated treatment of UVC and low dose Gamma irradiation to inactivate mixed Strains of Escherichia coli O157:H7 and Salmonella enterica inoculated on whole Grape tomatoes was evaluated. A mixed bacterial cocktail composed of a three strain mixture of E. coli O157:H7 (C9490, E02128 an...

  1. Integrated optimization of temperature, CO2, screen use and artificial lighting in greenhouse crops

    DEFF Research Database (Denmark)

    Aaslyng, J.M.; Körner, O.; Andreassen, A.U.

    2005-01-01

    A leaf photosynthesis model is suggested for integrated optimization of temperature, CO2, screen use and artificial lighting in greenhouse crops. Three different approaches for the optimization are presented. First, results from greenhouse experiments with model based optimization are presented....... Second, a model-based analysis of a commercial grower's production possibility is shown. Third, results from a simulation of the effect of a new lighting strategy are demonstrated. The results demonstrate that it is possible to optimize plant production by using a model-based integrated optimization...... of temperature, CO2, and light in the greenhouse...

  2. An Adaptive Intelligent Integrated Lighting Control Approach for High-Performance Office Buildings

    Science.gov (United States)

    Karizi, Nasim

    An acute and crucial societal problem is the energy consumed in existing commercial buildings. There are 1.5 million commercial buildings in the U.S. with only about 3% being built each year. Hence, existing buildings need to be properly operated and maintained for several decades. Application of integrated centralized control systems in buildings could lead to more than 50% energy savings. This research work demonstrates an innovative adaptive integrated lighting control approach which could achieve significant energy savings and increase indoor comfort in high performance office buildings. In the first phase of the study, a predictive algorithm was developed and validated through experiments in an actual test room. The objective was to regulate daylight on a specified work plane by controlling the blind slat angles. Furthermore, a sensor-based integrated adaptive lighting controller was designed in Simulink which included an innovative sensor optimization approach based on genetic algorithm to minimize the number of sensors and efficiently place them in the office. The controller was designed based on simple integral controllers. The objective of developed control algorithm was to improve the illuminance situation in the office through controlling the daylight and electrical lighting. To evaluate the performance of the system, the controller was applied on experimental office model in Lee et al.'s research study in 1998. The result of the developed control approach indicate a significantly improvement in lighting situation and 1-23% and 50-78% monthly electrical energy savings in the office model, compared to two static strategies when the blinds were left open and closed during the whole year respectively.

  3. High-dose simultaneously integrated breast boost using intensity-modulated radiotherapy and inverse optimization

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Meijer, Gert J.; Vliet-Vroegindeweij, Corine van; Sangen, Maurice J. van der; Cassee, Jorien

    2006-01-01

    Purpose: Recently a Phase III randomized trial has started comparing a boost of 16 Gy as part of whole-breast irradiation to a high boost of 26 Gy in young women. Our main aim was to develop an efficient simultaneously integrated boost (SIB) technique for the high-dose arm of the trial. Methods and Materials: Treatment planning was performed for 5 left-sided and 5 right-sided tumors. A tangential field intensity-modulated radiotherapy technique added to a sequentially planned 3-field boost (SEQ) was compared with a simultaneously planned technique (SIB) using inverse optimization. Normalized total dose (NTD)-corrected dose volume histogram parameters were calculated and compared. Results: The intended NTD was produced by 31 fractions of 1.66 Gy to the whole breast and 2.38 Gy to the boost volume. The average volume of the PTV-breast and PTV-boost receiving more than 95% of the prescribed dose was 97% or more for both techniques. Also, the mean lung dose and mean heart dose did not differ much between the techniques, with on average 3.5 Gy and 2.6 Gy for the SEQ and 3.8 Gy and 2.6 Gy for the SIB, respectively. However, the SIB resulted in a significantly more conformal irradiation of the PTV-boost. The volume of the PTV-breast, excluding the PTV-boost, receiving a dose higher than 95% of the boost dose could be reduced considerably using the SIB as compared with the SEQ from 129 cc (range, 48-262 cc) to 58 cc (range, 30-102 cc). Conclusions: A high-dose simultaneously integrated breast boost technique has been developed. The unwanted excessive dose to the breast was significantly reduced

  4. Energy and integrated dose dependence of MOSFET dosimeter for clinical electron beams

    International Nuclear Information System (INIS)

    Manigandan, D.; Bharanidharan, G.; Aruna, P.; Ganesan, S.; Tamil Kumar, T.; Rai

    2008-01-01

    In this study, the sensitivity (mV/cGy) and integral dose dependence of a MOSFET detector for different clinical electron beams was studied. Calibrated clinical electron beams (Varian 2100) were used for the exposure. A Markus type parallel plate chamber was used for the absolute dose measurements. In order to study the sensitivity of a MOSFET, the response of the ion chamber and MOSFET for the absorbed dose of 100 cGy was measured. The sensitivity of the MOSFET was then expressed as mV/cGy. Sensitivity was measured for 4-18 MeV electron beams. (author)

  5. Simple measurement of light-interception by individual leaves in fruit vegetables by using an integrated solarimeter film

    International Nuclear Information System (INIS)

    Watanabe, S.; Nakano, Y.; Okano, K.

    2001-01-01

    Applicability of the integrated solarimeter film (Taisei Chemical Co. Ltd., Optleaf R-2D) for the measurement of amount of light-interception by individual leaves in fruit vegetables was investigated The fading rate of the film was highly correlated with the values measured by an integrated solarimeter at an open field, though the rate was depended on the air temperature during the measurement. Integrated solar radiation in a glasshouse could be estimated by the film as well as at an open field. Amount of light-interception by individual leaves of vertically trained watermelon plants could be measured by the film and light-interception characteristics of the plants could be expressed numerically. The integrated solarimeter film would be useful for analyzing light-interception characteristics in fruit vegetables

  6. Use of cadmium sulphide to measure integrated dose in short-time irradiation

    International Nuclear Information System (INIS)

    Nimnual, S.

    1975-01-01

    An experiment was made to measure the dose from a short burst of X-rays in the order of 1 second or less by means of the cadmium sulphide photoconductive cell. If protected from light, the CdS cell has a very high resistance such that it does not discharge a capacitor appreciably. But during irradiation, the resistance decreases temporarily and an amount of charge will leak from the capacitor through the Ca S cell. The result to this experiment shows that the principle works very well but it is necessary to add another fixed high resistance of about 10 7 ohms into the circuit in order to get results independent of the dose-rate. The equipment used in this experiment can measure a dose as low as 6 m R

  7. Chem/bio sensing with non-classical light and integrated photonics.

    Science.gov (United States)

    Haas, J; Schwartz, M; Rengstl, U; Jetter, M; Michler, P; Mizaikoff, B

    2018-01-29

    Modern quantum technology currently experiences extensive advances in applicability in communications, cryptography, computing, metrology and lithography. Harnessing this technology platform for chem/bio sensing scenarios is an appealing opportunity enabling ultra-sensitive detection schemes. This is further facilliated by the progress in fabrication, miniaturization and integration of visible and infrared quantum photonics. Especially, the combination of efficient single-photon sources together with waveguiding/sensing structures, serving as active optical transducer, as well as advanced detector materials is promising integrated quantum photonic chem/bio sensors. Besides the intrinsic molecular selectivity and non-destructive character of visible and infrared light based sensing schemes, chem/bio sensors taking advantage of non-classical light sources promise sensitivities beyond the standard quantum limit. In the present review, recent achievements towards on-chip chem/bio quantum photonic sensing platforms based on N00N states are discussed along with appropriate recognition chemistries, facilitating the detection of relevant (bio)analytes at ultra-trace concentration levels. After evaluating recent developments in this field, a perspective for a potentially promising sensor testbed is discussed for reaching integrated quantum sensing with two fiber-coupled GaAs chips together with semiconductor quantum dots serving as single-photon sources.

  8. Temperature Characteristics of Monolithically Integrated Wavelength-Selectable Light Sources

    International Nuclear Information System (INIS)

    Han Liang-Shun; Zhu Hong-Liang; Zhang Can; Ma Li; Liang Song; Wang Wei

    2013-01-01

    The temperature characteristics of monolithically integrated wavelength-selectable light sources are experimentally investigated. The wavelength-selectable light sources consist of four distributed feedback (DFB) lasers, a multimode interferometer coupler, and a semiconductor optical amplifier. The oscillating wavelength of the DFB laser could be modulated by adjusting the device operating temperature. A wavelength range covering over 8.0nm is obtained with stable single-mode operation by selecting the appropriate laser and chip temperature. The thermal crosstalk caused by the lateral heat spreading between lasers operating simultaneously is evaluated by oscillating-wavelength shift. The thermal crosstalk approximately decreases exponentially as the increasing distance between lasers

  9. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  10. A MoTe2-based light-emitting diode and photodetector for silicon photonic integrated circuits.

    Science.gov (United States)

    Bie, Ya-Qing; Grosso, Gabriele; Heuck, Mikkel; Furchi, Marco M; Cao, Yuan; Zheng, Jiabao; Bunandar, Darius; Navarro-Moratalla, Efren; Zhou, Lin; Efetov, Dmitri K; Taniguchi, Takashi; Watanabe, Kenji; Kong, Jing; Englund, Dirk; Jarillo-Herrero, Pablo

    2017-12-01

    One of the current challenges in photonics is developing high-speed, power-efficient, chip-integrated optical communications devices to address the interconnects bottleneck in high-speed computing systems. Silicon photonics has emerged as a leading architecture, in part because of the promise that many components, such as waveguides, couplers, interferometers and modulators, could be directly integrated on silicon-based processors. However, light sources and photodetectors present ongoing challenges. Common approaches for light sources include one or few off-chip or wafer-bonded lasers based on III-V materials, but recent system architecture studies show advantages for the use of many directly modulated light sources positioned at the transmitter location. The most advanced photodetectors in the silicon photonic process are based on germanium, but this requires additional germanium growth, which increases the system cost. The emerging two-dimensional transition-metal dichalcogenides (TMDs) offer a path for optical interconnect components that can be integrated with silicon photonics and complementary metal-oxide-semiconductors (CMOS) processing by back-end-of-the-line steps. Here, we demonstrate a silicon waveguide-integrated light source and photodetector based on a p-n junction of bilayer MoTe 2 , a TMD semiconductor with an infrared bandgap. This state-of-the-art fabrication technology provides new opportunities for integrated optoelectronic systems.

  11. A MoTe2-based light-emitting diode and photodetector for silicon photonic integrated circuits

    Science.gov (United States)

    Bie, Ya-Qing; Grosso, Gabriele; Heuck, Mikkel; Furchi, Marco M.; Cao, Yuan; Zheng, Jiabao; Bunandar, Darius; Navarro-Moratalla, Efren; Zhou, Lin; Efetov, Dmitri K.; Taniguchi, Takashi; Watanabe, Kenji; Kong, Jing; Englund, Dirk; Jarillo-Herrero, Pablo

    2017-12-01

    One of the current challenges in photonics is developing high-speed, power-efficient, chip-integrated optical communications devices to address the interconnects bottleneck in high-speed computing systems. Silicon photonics has emerged as a leading architecture, in part because of the promise that many components, such as waveguides, couplers, interferometers and modulators, could be directly integrated on silicon-based processors. However, light sources and photodetectors present ongoing challenges. Common approaches for light sources include one or few off-chip or wafer-bonded lasers based on III-V materials, but recent system architecture studies show advantages for the use of many directly modulated light sources positioned at the transmitter location. The most advanced photodetectors in the silicon photonic process are based on germanium, but this requires additional germanium growth, which increases the system cost. The emerging two-dimensional transition-metal dichalcogenides (TMDs) offer a path for optical interconnect components that can be integrated with silicon photonics and complementary metal-oxide-semiconductors (CMOS) processing by back-end-of-the-line steps. Here, we demonstrate a silicon waveguide-integrated light source and photodetector based on a p-n junction of bilayer MoTe2, a TMD semiconductor with an infrared bandgap. This state-of-the-art fabrication technology provides new opportunities for integrated optoelectronic systems.

  12. Integrated source of broadband quadrature squeezed light

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk; Nielsen, Bo Melholt; Andersen, Ulrik Lund

    2015-01-01

    An integrated silicon nitride resonator is proposed as an ultracompact source of bright single-mode quadrature squeezed light at 850 nm. Optical properties of the device are investigated and tailored through numerical simulations, with particular attention paid to loss associated with interfacing...... the device. An asymmetric double layer stack waveguide geometry with inverse vertical tapers is proposed for efficient and robust fibre-chip coupling, yielding a simulated total loss of -0.75 dB/facet. We assess the feasibility of the device through a full quantum noise analysis and derive the output...

  13. RISC-RAD. A European integrated approach to the problem of low doses

    International Nuclear Information System (INIS)

    Meunier, A.; Sabatier, L.; Atkinson, M.; Paretzke, H.; Bouffler, S.; Mullenders, L.

    2007-01-01

    Complete text of publication follows. Funded by the European Commission in the framework of a dedicated programme supporting research in the Nuclear sector (FP6 Euratom), the project RISC-RAD undertakes experimental and modelling studies ultimately to improve low dose radiation cancer risk assessment by exploring and providing evidence for the most appropriate radiation cancer risk projection and interpolation models. It started on 1st January 2004 and is running until 31 st October 2008. It mobilizes a consortium of 31 partners and is coordinated by Dr. Laure Sabatier from the French atomic energy commission. Indeed the project represents an unprecedented attempt to integrate horizontally the research on the effects of low doses of IR at the European level. A multipartner project supporting objective-driven research, RISC-RAD aims at contributing to bridge the remaining gap of scientific knowledge about effects of lows doses of ionizing radiation. It spans a large part of the research spectrum, including many topics addressed during the LOWRAD2007 conference. This presentation intends to give an account of the integrative aspects of the project, insights on the innovative solutions found to approach a complex and controversial scientific topic like the biological effects of low doses of ionizing radiation, and links with some areas of social studies on science.The concept of 'integration' implies the development of a new kind of activity in the research field, which crosses its traditional boundaries : controversies of several kinds must temporarily be overcome within the project management board in order to define and follow a common strategy. Among them, how to reconcile the creative part of fundamental research with the compliance to strict project planning rules has come up as a debate which questions the best way a significant collective and coordinated action can address the issue of the low dose cancer risk assessment on the long term. The knowledge and

  14. Integrated Quantum Optics: Experiments towards integrated quantum-light sources and quantum-enhanced sensing

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk

    The work presented in this thesis is focused on experimental application and generation of continuous variable quantum correlated states of light in integrated dielectric structures. Squeezed states are among the most exploited continuous variable optical states for free-space quantum-enhanced se...... is presented and an optimized device design is proposed. The devices have been fabricated and tested optically and preliminary interrogations of the output quantum noise have been performed....

  15. Integrated numerical platforms for environmental dose assessments of large tritium inventory facilities

    International Nuclear Information System (INIS)

    Castro, P.; Ardao, J.; Velarde, M.; Sedano, L.; Xiberta, J.

    2013-01-01

    Related with a prospected new scenario of large inventory tritium facilities [KATRIN at TLK, CANDUs, ITER, EAST, other coming] the prescribed dosimetric limits by ICRP-60 for tritium committed-doses are under discussion requiring, in parallel, to surmount the highly conservative assessments by increasing the refinement of dosimetric-assessments in many aspects. Precise Lagrangian-computations of dosimetric cloud-evolution after standardized (normal/incidental/SBO) tritium cloud emissions are today numerically open to the perfect match of real-time meteorological-data, and patterns data at diverse scales for prompt/early and chronic tritium dose assessments. The trends towards integrated-numerical-platforms for environmental-dose assessments of large tritium inventory facilities under development.

  16. Broadband integrated mid infrared light sources as enabling technology for point of care mid-infrared spectroscopy

    Science.gov (United States)

    2017-08-20

    AFRL-AFOSR-JP-TR-2017-0061 Broadband integrated mid-infrared light sources as enabling technology for point-of-care mid- infrared spectroscopy Alex...mid-infrared light sources as enabling technology for point-of-care mid-infrared spectroscopy 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA2386-16-1-4037...Broadband integrated mid-infrared light sources as enabling technology for point-of-care mid- infrared spectroscopy ” Date: 16th August 2017 Name

  17. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  18. Plasmonic nanofocusing of light in an integrated silicon photonics platform.

    Science.gov (United States)

    Desiatov, Boris; Goykhman, Ilya; Levy, Uriel

    2011-07-04

    The capability to focus electromagnetic energy at the nanoscale plays an important role in nanoscinece and nanotechnology. It allows enhancing light matter interactions at the nanoscale with applications related to nonlinear optics, light emission and light detection. It may also be used for enhancing resolution in microscopy, lithography and optical storage systems. Hereby we propose and experimentally demonstrate the nanoscale focusing of surface plasmons by constructing an integrated plasmonic/photonic on chip nanofocusing device in silicon platform. The device was tested directly by measuring the optical intensity along it using a near-field microscope. We found an order of magnitude enhancement of the intensity at the tip's apex. The spot size is estimated to be 50 nm. The demonstrated device may be used as a building block for "lab on a chip" systems and for enhancing light matter interactions at the apex of the tip.

  19. Disruption of cortical integration during midazolam-induced light sedation.

    Science.gov (United States)

    Liang, Peipeng; Zhang, Han; Xu, Yachao; Jia, Wenbin; Zang, Yufeng; Li, Kuncheng

    2015-11-01

    This work examines the effect of midazolam-induced light sedation on intrinsic functional connectivity of human brain, using a randomized, double-blind, placebo-controlled, cross-over, within-subject design. Fourteen healthy young subjects were enrolled and midazolam (0.03 mg/kg of the participant's body mass, to a maximum of 2.5 mg) or saline were administrated with an interval of one week. Resting-state fMRI was conducted before and after administration for each subject. We focus on two types of networks: sensory related lower-level functional networks and higher-order functions related ones. Independent component analysis (ICA) was used to identify these resting-state functional networks. We hypothesize that the sensory (visual, auditory, and sensorimotor) related networks will be intact under midazolam-induced light sedation while the higher-order (default mode, executive control, salience networks, etc.) networks will be functionally disconnected. It was found that the functional integrity of the lower-level networks was maintained, while that of the higher-level networks was significantly disrupted by light sedation. The within-network connectivity of the two types of networks was differently affected in terms of direction and extent. These findings provide direct evidence that higher-order cognitive functions including memory, attention, executive function, and language were impaired prior to lower-level sensory responses during sedation. Our result also lends support to the information integration model of consciousness. © 2015 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.

  20. Design and radiation tests on a LED based emergency evacuation directional lighting

    CERN Document Server

    Trikoupis, Nikolaos

    2017-01-01

    A LED (Light Emitting Diode) based directional lighting system has been designed to indicate the best evacuation direction for applications like the Large Hadron Collider (LHC) tunnel. The design includes constraints for redundancy required by safety systems and for components selection by radiation effects. Most of the literature for radiation effects on LEDs concern digital communications systems, although some recent reports do exist for visible spectrum power LEDs and the reduction in light output versus dose is coherent with the results presented in this paper. Prototype lighting units were irradiated in CERN’s CHARM facility up to a Total Integrated Dose (TID) of 870 Gy and no failures were observed. This paper describes the basic design, presents field tests and the effects of radiation on the LEDs luminance.

  1. Developing a flexible and verifiable integrated dose assessment capability

    International Nuclear Information System (INIS)

    Parzyck, D.C.; Rhea, T.A.; Copenhaver, E.D.; Bogard, J.S.

    1987-01-01

    A flexible yet verifiable system of computing and recording personnel doses is needed. Recent directions in statutes establish the trend of combining internal and external doses. We are developing a Health Physics Information Management System (HPIMS) that will centralize dosimetry calculations and data storage; integrate health physics records with other health-related disciplines, such as industrial hygiene, medicine, and safety; provide a more auditable system with published algorithms and clearly defined flowcharts of system operation; readily facilitate future changes dictated by new regulations, new dosimetric models, and new systems of units; and address ad-hoc inquiries regarding worker/workplace interactions, including potential synergisms with non-radiation exposures. The system is modular and provides a high degree of isolation from low-level detail, allowing flexibility for changes without adversely affecting other parts of the system. 10 refs., 3 figs

  2. A hybrid lightwave transmission system based on light injection/optoelectronic feedback techniques and fiber-VLLC integration

    International Nuclear Information System (INIS)

    Tsai, Wen-Shing; Lu, Hai-Han; Li, Chung-Yi; Chen, Bo-Rui; Lin, Hung-Hsien; Lin, Dai-Hua

    2016-01-01

    A hybrid lightwave transmission system based on light injection/optoelectronic feedback techniques and fiber-visible laser light communication (VLLC) integration is proposed and experimentally demonstrated. To be the first one of its kind in employing light injection and optoelectronic feedback techniques in a fiber-VLLC integration lightwave transmission system, the light is successfully directly modulated with Community Access Television (CATV), 16-QAM, and 16-QAM-OFDM signals. Over a 40 km SMF and a 10 m free-space VLLC transport, good performances of carrier-to-noise ratio (CNR)/composite second-order (CSO)/composite triple-beat (CTB)/bit error rate (BER) are achieved for CATV/16-QAM/16-QAM-OFDM signals transmission. Such a hybrid lightwave transmission system would be very useful since it can provide broadband integrated services including CATV, Internet, and telecommunication services over both distribute fiber and in-building networks. (letter)

  3. Independent dose calculation in IMRT for the Tps Iplan using the Clarkson modified integral

    International Nuclear Information System (INIS)

    Adrada, A.; Tello, Z.; Garrigo, E.; Venencia, D.

    2014-08-01

    Intensity-Modulated Radiation Therapy (IMRT) treatments require a quality assurance (Q A) specific patient before delivery. These controls include the experimental verification in dose phantom of the total plan as well as dose distributions. The use of independent dose calculation (IDC) is used in 3D-Crt treatments; however its application in IMRT requires the implementation of an algorithm that allows considering a non-uniform intensity beam. The purpose of this work was to develop IDC software in IMRT with MLC using the algorithm proposed by Kung (Kung et al. 2000). The software was done using Matlab programming. The Clarkson modified integral was implemented on each flowing, applying concentric rings for the dose determination. From the integral of each field was calculated the dose anywhere. One time finished a planning; all data are exported to a phantom where a Q A plan is generated. On this is calculated the half dose in a representative volume of the ionization chamber and the dose at the center of it. Until now 230 IMRT planning were analyzed carried out ??in the treatment planning system (Tps) Iplan. For each one of them Q A plan was generated, were calculated and compared calculated dose with the Tps, IDC system and measurement with ionization chamber. The average difference between measured and calculated dose with the IDC system was 0.4% ± 2.2% [-6.8%, 6.4%]. The difference between the measured and the calculated doses by the pencil-beam algorithm (Pb) of Tps was 2.6% ± 1.41% [-2.0%, 5.6%] and with the Monte Carlo algorithm was 0.4% ± 1.5% [-4.9%, 3.7%]. The differences of the carried out software are comparable to the obtained with the ionization chamber and Tps in Monte Carlo mode. (author)

  4. Optical Characteristics of a Multichannel Hybrid Integrated Light Source for Ultra-High-Bandwidth Optical Interconnections

    Directory of Open Access Journals (Sweden)

    Takanori Shimizu

    2015-11-01

    Full Text Available The optical characteristics of a multi-channel hybrid integrated light source were described for an optical interconnection with a bandwidth of over 10 Tbit/s. The power uniformity of the relative intensity of a 1000-channel light source was shown, and the minimum standard deviation s of the optical power of the 200 output ports at each 25-channel laser diode (LD array was estimated to be 0.49 dB. This hybrid integrated light source is expected to be easily adaptable to a photonics-electronics convergence system for ultra-high-bandwidth interchip interconnections.

  5. Red Light-Dose or Wavelength-Dependent Photoresponse of Antioxidants in Herb Microgreens.

    Directory of Open Access Journals (Sweden)

    Giedė Samuolienė

    Full Text Available The purpose of this study was to evaluate the role of 638-nm and 665-nm LEDs on changes of antioxidants of basil (Ocimum basilicum and parsley (Petroselinum crispum, and to assess the effect of light quality on antioxidative status. Plants were grown in peat substrate for 19 days (21/17 ±2°C, 16 h. Experiments were performed in (I a controlled-environment: B455,R638,R665,FR731(control; B455,R*638,R665,FR731; B455,R638,R*665,FR731; R638; R665 (B-blue, R- red, FR-far-red light. PPFD was set from 231 during growth, upto 300 μmol m-2 s-1 during 3-day treatment changing R638 or R665 PPFD level; in (II greenhouse (November: high-pressure sodium lamps (HPS (control-300 μmol m-2s-1; and HPS + 638 (HPS generated 90 and red LEDs-210 μmol m-2s-1. In general, under supplemental or increased red 638 nm light, amounts of tested antioxidants were greater in basil, whereas sole 665 nm or sole 638 nm is more favourable for parsley. Increased or supplemental red light significantly increased contents of phenolics, α-tocopherol, ascorbic acid and DPPH• but suppressed accumulation of lutein and β-carotene in basil, whereas an increase of β-carotene and DPPH• was observed in parsley. Hereby, the photoresponse of antioxidant compounds suggests that photoprotective mechanism is stimulated by both light-dose-dependent and wavelength-dependent reactions.

  6. Stechiometric neodymium compounds as new materials for light sources in integrated optics

    International Nuclear Information System (INIS)

    Malinowski, M.

    1981-01-01

    Short review of physico-chemical properties of stechiometric neodymium compounds has been presented. Several constructions of minilasers as promising light sources for integrated optics devices have been described. (author)

  7. Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Kaveh Shirani Tak Abi

    2015-05-01

    Full Text Available Introduction Intensity-Modulated Radiotherapy (IMRT is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the patient. The aim of the present study was to calculate and compare the integral dose in normal and target organs in two different procedures of IMRT: Step-and-Shoot (SAS and compensator-based IMRT. Materials and Methods In this comparative study, five patients with prostate cancer were selected. Module Integrated Radiotherapy System was applied, using three energy ranges. In both treatment planning methods, the integral dose dramatically decreased by increasing energy. Results Comparison of two treatment methods showed that on average, the integral dose of body in SAS radiation therapy was about 1.62% lower than that reported in compensator-based IMRT. In planning target volume, rectum, bladder, and left and right femoral heads, the integral doses for SAS method were 1.01%, 1.02%, 1.11%, 1.47%, and 1.40% lower than compensator-based IMRT, respectively. Conclusion Considering the treatment conditions, the definition of dose volume constraints for healthy tissues, and the equal volume of organs in both treatment methods, SAS radiation therapy by providing a lower integral dose seems to be more advantageous and efficient for prostate cancer treatment, compared to compensator-based IMRT.

  8. Providing Power Supply to Other Use Cases Integrated in the System of Public Lighting

    OpenAIRE

    Perko, Jurica; Topić, Danijel; Šljivac, Damir

    2017-01-01

    Smart city is an attractive way of making the city more livable through intelligent solutions that are enabled by information and communication technology. Regarding the lighting system, it achieves the perfect balance between beautiful city ambience and preserving the darkness that makes cities more livable. As a smart city component, a public lighting system offers much more than light itself. Integration of other use cases has given a new dimension to the public lighting system in visual a...

  9. An integrated single- and two-photon non-diffracting light-sheet microscope

    Science.gov (United States)

    Lau, Sze Cheung; Chiu, Hoi Chun; Zhao, Luwei; Zhao, Teng; Loy, M. M. T.; Du, Shengwang

    2018-04-01

    We describe a fluorescence optical microscope with both single-photon and two-photon non-diffracting light-sheet excitations for large volume imaging. With a special design to accommodate two different wavelength ranges (visible: 400-700 nm and near infrared: 800-1200 nm), we combine the line-Bessel sheet (LBS, for single-photon excitation) and the scanning Bessel beam (SBB, for two-photon excitation) light sheet together in a single microscope setup. For a transparent thin sample where the scattering can be ignored, the LBS single-photon excitation is the optimal imaging solution. When the light scattering becomes significant for a deep-cell or deep-tissue imaging, we use SBB light-sheet two-photon excitation with a longer wavelength. We achieved nearly identical lateral/axial resolution of about 350/270 nm for both imagings. This integrated light-sheet microscope may have a wide application for live-cell and live-tissue three-dimensional high-speed imaging.

  10. Marked improvement by high-dose chemotherapy and autologous stem cell transplantation in a case of light chain deposition disease.

    Science.gov (United States)

    Matsuzaki, Keiichi; Ohsawa, Isao; Nishitani, Tomohito; Takeda, Yukihiko; Inoshita, Hiroyuki; Ishii, Masaya; Takagi, Miyuki; Horikoshi, Satoshi; Tomino, Yasuhiko

    2011-01-01

    A 55-year-old woman presented with heavy proteinuria (6.2 g/day) in April 2007. Because monoclonal IgG-k was detected in serum and urine samples, bone marrow aspiration and renal biopsy were performed. She was diagnosed with plasma cell dyscrasia because a bone marrow aspiration specimen showed plasma cells at 6.1%. Renal tissues revealed the formation of nodular glomerulosclerosis which was negative for Congo-red staining. Renal immunohistochemistry showed positive staining for kappa light chains in the nodular lesions, proximal tubules and part of Bowman's capsules. Her renal involvement was diagnosed as light chain deposition disease. Proteinuria disappeared and renal function stabilized after high-dose chemotherapy and autologous stem cell transplantation. It appears that an early initiation of active therapy such as high-dose chemotherapy and autologous stem cell transplantation may be beneficial for patients with light chain deposition disease.

  11. Three-Dimensional Hetero-Integration of Faceted GaN on Si Pillars for Efficient Light Energy Conversion Devices.

    Science.gov (United States)

    Kim, Dong Rip; Lee, Chi Hwan; Cho, In Sun; Jang, Hanmin; Jeon, Min Soo; Zheng, Xiaolin

    2017-07-25

    An important pathway for cost-effective light energy conversion devices, such as solar cells and light emitting diodes, is to integrate III-V (e.g., GaN) materials on Si substrates. Such integration first necessitates growth of high crystalline III-V materials on Si, which has been the focus of many studies. However, the integration also requires that the final III-V/Si structure has a high light energy conversion efficiency. To accomplish these twin goals, we use single-crystalline microsized Si pillars as a seed layer to first grow faceted Si structures, which are then used for the heteroepitaxial growth of faceted GaN films. These faceted GaN films on Si have high crystallinity, and their threading dislocation density is similar to that of GaN grown on sapphire. In addition, the final faceted GaN/Si structure has great light absorption and extraction characteristics, leading to improved performance for GaN-on-Si light energy conversion devices.

  12. Integrated High Resolution Digital Color Light Sensor in 130 nm CMOS Technology

    Directory of Open Access Journals (Sweden)

    Drago Strle

    2015-07-01

    Full Text Available This article presents a color light detection system integrated in 130 nm CMOS technology. The sensors and corresponding electronics detect light in a CIE XYZ color luminosity space using on-chip integrated sensors without any additional process steps, high-resolution analog-to-digital converter, and dedicated DSP algorithm. The sensor consists of a set of laterally arranged integrated photodiodes that are partly covered by metal, where color separation between the photodiodes is achieved by lateral carrier diffusion together with wavelength-dependent absorption. A high resolution, hybrid, ∑∆ ADC converts each photo diode’s current into a 22-bit digital result, canceling the dark current of the photo diodes. The digital results are further processed by the DSP, which calculates normalized XYZ or RGB color and intensity parameters using linear transformations of the three photo diode responses by multiplication of the data with a transformation matrix, where the coefficients are extracted by training in combination with a pseudo-inverse operation and the least-mean square approximation. The sensor system detects the color light parameters with 22-bit accuracy, consumes less than 60 μA on average at 10 readings per second, and occupies approx. 0.8 mm2 of silicon area (including three photodiodes and the analog part of the ADC. The DSP is currently implemented on FPGA.

  13. Integrated High Resolution Digital Color Light Sensor in 130 nm CMOS Technology.

    Science.gov (United States)

    Strle, Drago; Nahtigal, Uroš; Batistell, Graciele; Zhang, Vincent Chi; Ofner, Erwin; Fant, Andrea; Sturm, Johannes

    2015-07-22

    This article presents a color light detection system integrated in 130 nm CMOS technology. The sensors and corresponding electronics detect light in a CIE XYZ color luminosity space using on-chip integrated sensors without any additional process steps, high-resolution analog-to-digital converter, and dedicated DSP algorithm. The sensor consists of a set of laterally arranged integrated photodiodes that are partly covered by metal, where color separation between the photodiodes is achieved by lateral carrier diffusion together with wavelength-dependent absorption. A high resolution, hybrid, ∑∆ ADC converts each photo diode's current into a 22-bit digital result, canceling the dark current of the photo diodes. The digital results are further processed by the DSP, which calculates normalized XYZ or RGB color and intensity parameters using linear transformations of the three photo diode responses by multiplication of the data with a transformation matrix, where the coefficients are extracted by training in combination with a pseudo-inverse operation and the least-mean square approximation. The sensor system detects the color light parameters with 22-bit accuracy, consumes less than 60 μA on average at 10 readings per second, and occupies approx. 0.8 mm(2) of silicon area (including three photodiodes and the analog part of the ADC). The DSP is currently implemented on FPGA.

  14. A cortical edge-integration model of object-based lightness computation that explains effects of spatial context and individual differences

    Science.gov (United States)

    Rudd, Michael E.

    2014-01-01

    Previous work has demonstrated that perceived surface reflectance (lightness) can be modeled in simple contexts in a quantitatively exact way by assuming that the visual system first extracts information about local, directed steps in log luminance, then spatially integrates these steps along paths through the image to compute lightness (Rudd and Zemach, 2004, 2005, 2007). This method of computing lightness is called edge integration. Recent evidence (Rudd, 2013) suggests that human vision employs a default strategy to integrate luminance steps only along paths from a common background region to the targets whose lightness is computed. This implies a role for gestalt grouping in edge-based lightness computation. Rudd (2010) further showed the perceptual weights applied to edges in lightness computation can be influenced by the observer's interpretation of luminance steps as resulting from either spatial variation in surface reflectance or illumination. This implies a role for top-down factors in any edge-based model of lightness (Rudd and Zemach, 2005). Here, I show how the separate influences of grouping and attention on lightness can be modeled in tandem by a cortical mechanism that first employs top-down signals to spatially select regions of interest for lightness computation. An object-based network computation, involving neurons that code for border-ownership, then automatically sets the neural gains applied to edge signals surviving the earlier spatial selection stage. Only the borders that survive both processing stages are spatially integrated to compute lightness. The model assumptions are consistent with those of the cortical lightness model presented earlier by Rudd (2010, 2013), and with neurophysiological data indicating extraction of local edge information in V1, network computations to establish figure-ground relations and border ownership in V2, and edge integration to encode lightness and darkness signals in V4. PMID:25202253

  15. A Cortical Edge-integration Model of Object-Based Lightness Computation that Explains Effects of Spatial Context and Individual Differences

    Directory of Open Access Journals (Sweden)

    Michael E Rudd

    2014-08-01

    Full Text Available Previous work demonstrated that perceived surface reflectance (lightness can be modeled in simple contexts in a quantitatively exact way by assuming that the visual system first extracts information about local, directed steps in log luminance, then spatial integrates these steps along paths through the image to compute lightness (Rudd & Zemach, 2004, 2005, 2007. This method of computing lightness is called edge integration. Recent evidence (Rudd, 2013 suggests that the human vision employs a default strategy to integrate luminance steps only along paths from a common background region to the targets whose lightness is computed. This implies a role for gestalt grouping in edge-based lightness computation. Rudd (2010 further showed the perceptual weights applied to edges in lightness computation can be influenced by the observer’s interpretation of luminance steps as resulting from either spatial variation in surface reflectance or illumination. This implies a role for top-down factors in any edge-based model of lightness (Rudd & Zemach, 2005. Here, I show how the separate influences of grouping and attention on lightness can be together modeled by a cortical mechanism that first employs top-down signals to spatially select regions of interest for lightness computation. An object-based network computation, involving neurons that code for border-ownership, then automatically sets the neural gains applied to edge signals surviving the earlier spatial selection stage. Only the borders that survive both processing stages are spatially integrated to compute lightness. The model assumptions are consistent with those of the cortical lightness model presented earlier by Rudd (2010, 2013, and with neurophysiological data indicating extraction of local edge information in V1, network computations to establish figure-ground relations and border ownership in V2, and edge integration to encode lightness and darkness signals in V4.

  16. A cortical edge-integration model of object-based lightness computation that explains effects of spatial context and individual differences.

    Science.gov (United States)

    Rudd, Michael E

    2014-01-01

    Previous work has demonstrated that perceived surface reflectance (lightness) can be modeled in simple contexts in a quantitatively exact way by assuming that the visual system first extracts information about local, directed steps in log luminance, then spatially integrates these steps along paths through the image to compute lightness (Rudd and Zemach, 2004, 2005, 2007). This method of computing lightness is called edge integration. Recent evidence (Rudd, 2013) suggests that human vision employs a default strategy to integrate luminance steps only along paths from a common background region to the targets whose lightness is computed. This implies a role for gestalt grouping in edge-based lightness computation. Rudd (2010) further showed the perceptual weights applied to edges in lightness computation can be influenced by the observer's interpretation of luminance steps as resulting from either spatial variation in surface reflectance or illumination. This implies a role for top-down factors in any edge-based model of lightness (Rudd and Zemach, 2005). Here, I show how the separate influences of grouping and attention on lightness can be modeled in tandem by a cortical mechanism that first employs top-down signals to spatially select regions of interest for lightness computation. An object-based network computation, involving neurons that code for border-ownership, then automatically sets the neural gains applied to edge signals surviving the earlier spatial selection stage. Only the borders that survive both processing stages are spatially integrated to compute lightness. The model assumptions are consistent with those of the cortical lightness model presented earlier by Rudd (2010, 2013), and with neurophysiological data indicating extraction of local edge information in V1, network computations to establish figure-ground relations and border ownership in V2, and edge integration to encode lightness and darkness signals in V4.

  17. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware.

    Science.gov (United States)

    Rosca, Florin

    2012-06-01

    To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E+IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. The normal tissue integral dose was lowered by about 20% by the E+IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E+IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E+IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning

  18. Integration Issues for Using Innovative Daylighting Strategies in Light Wells

    Directory of Open Access Journals (Sweden)

    Gashinani M. Gholipour

    2017-12-01

    Full Text Available “Light well” as one of the most common means of daylight tolls in building, experiences severe limitations and deserve special attention. The question is which strategy is the best for increasing the daylight penetration to the depth of buildings. One of the main challenges in deep plan is to guide daylight into the building core and this can be performed through daylighting strategies, but the choice of the proper innovative daylighting system (IDS with several parameters is the problem. This paper aims to find elements for optimal choice and selecting context-compatible tools for light well. The result shows that four macro factors were found at the interaction of building and IDS. Identifying the integration components can play an effective role in decision-making or design a new tolls consistent with the physical conditions of light well and building to overcome the daylight crisis.

  19. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  20. Light collection optics for measuring flux and spectrum from light-emitting devices

    Science.gov (United States)

    McCord, Mark A.; DiRegolo, Joseph A.; Gluszczak, Michael R.

    2016-05-24

    Systems and methods for accurately measuring the luminous flux and color (spectra) from light-emitting devices are disclosed. An integrating sphere may be utilized to directly receive a first portion of light emitted by a light-emitting device through an opening defined on the integrating sphere. A light collector may be utilized to collect a second portion of light emitted by the light-emitting device and direct the second portion of light into the integrating sphere through the opening defined on the integrating sphere. A spectrometer may be utilized to measure at least one property of the first portion and the second portion of light received by the integrating sphere.

  1. Impact of doped boron concentration in emitter on high- and low-dose-rate damage in lateral PNP transistors

    International Nuclear Information System (INIS)

    Zheng Yuzhan; Lu Wu; Ren Diyuan; Wang Yiyuan; Wang Zhikuan; Yang Yonghui

    2010-01-01

    The characteristics of radiation damage under a high or low dose rate in lateral PNP transistors with a heavily or lightly doped emitter is investigated. Experimental results show that as the total dose increases, the base current of transistors would increase and the current gain decreases. Furthermore, more degradation has been found in lightly-doped PNP transistors, and an abnormal effect is observed in heavily doped transistors. The role of radiation defects, especially the double effects of oxide trapped charge, is discussed in heavily or lightly doped transistors. Finally, through comparison between the high- and low-dose-rate response of the collector current in heavily doped lateral PNP transistors, the abnormal effect can be attributed to the annealing of the oxide trapped charge. The response of the collector current, in heavily doped PNP transistors under high- and low-dose-rate irradiation is described in detail. (semiconductor integrated circuits)

  2. Dose calculations for irregular fields using three-dimensional first-scatter integration

    International Nuclear Information System (INIS)

    Boesecke, R.; Scharfenberg, H.; Schlegel, W.; Hartmann, G.H.

    1986-01-01

    This paper describes a method of dose calculations for irregular fields which requires only the mean energy of the incident photons, the geometrical properties of the irregular field and of the therapy unit, and the attenuation coefficient of tissue. The method goes back to an approach including spatial aspects of photon scattering for inhomogeneities for the calculation of dose reduction factors as proposed by Sontag and Cunningham (1978). It is based on the separation of dose into a primary component and a scattered component. The scattered component can generally be calculated for each field by integration over dose contributions from scattering in neighbouring volume elements. The quotient of this scattering contribution in the irregular field and the scattering contribution in the equivalent open field is then the correction factor for scattering in an irregular field. A correction factor for the primary component can be calculated if the attenuation of the photons in the shielding block is properly taken into account. The correction factor is simply given by the quotient of primary photons of the irregular field and the primary photons of the open field. (author)

  3. Insulator photocurrents: Application to dose rate hardening of CMOS/SOI integrated circuits

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.; Coiec, Y.M.; Flament, O.; Tinel, F.

    1998-01-01

    Irradiation of insulators with a pulse of high energy x-rays can induce photocurrents in the interconnections of integrated circuits. The authors present, here, a new method to measure and analyze this effect together with a simple model. They also demonstrate that these insulator photocurrents have to be taken into account to obtain high levels of dose-rate hardness with CMOS on SOI integrated circuits, especially flip-flops or memory blocks of ASICs. They show that it explains some of the upsets observed in a SRAM embedded in an ASIC

  4. Radiation monitoring in a synchrotron light source facility using magnetically levitated electrode ionization chambers

    International Nuclear Information System (INIS)

    Ichiki, Hirofumi; Kawaguchi, Toshirou; Utsunomiya, Yoshitomo; Ishibashi, Kenji; Ikeda, Nobuo; Korenaga, Kazuhito

    2009-01-01

    We developed a highly accurate differential-type automatic radiation dosimeter to measure very low radiation doses. The dosimeter had two ionization chambers, each of which had a magnetically levitated electrode and it was operated in a repetitive-time integration mode. We first installed the differential-type automatic radiation dosimeter with MALICs at a high-energy electron accelerator facility (Kyushu Synchrotron Light Research Center Facility) and measured the background and ionizing radiations in the facility as well as the gaseous radiation in air. In the background dose measurements, the accuracy of the repetitive-time integration-type dosimeter was three times better than that of a commercial ionization chamber. When the radiation dose increased momentarily at the electron injection from the linac to the operating storage ring, the dosimeter with repetitive-time integral mode gave a successful response to the actual dose variation. The gaseous radiation dose in the facility was at the same level as that in Fukuoka City. We confirmed that the dosimeter with magnetically levitated electrode ionization chambers was usable in the accelerator facility, in spite of its limited response when operated in the repetitive-time integration mode. (author)

  5. Double light-cone dynamics establish thermal states in integrable 1D Bose gases

    Science.gov (United States)

    Langen, T.; Schweigler, T.; Demler, E.; Schmiedmayer, J.

    2018-02-01

    We theoretically investigate the non-equilibrium dynamics in a quenched pair of one-dimensional Bose gases with density imbalance. We describe the system using its low-energy effective theory, the Luttinger liquid model. In this framework the system shows strictly integrable relaxation dynamics via dephasing of its approximate many-body eigenstates. In the balanced case, this leads to the well-known light-cone-like establishment of a prethermalized state, which can be described by a generalized Gibbs ensemble. In the imbalanced case the integrable dephasing leads to a state that, counter-intuitively, closely resembles a thermal equilibrium state. The approach to this state is characterized by two separate light-cone dynamics with distinct characteristic velocities. This behavior is a result of the fact that in the imbalanced case observables are not aligned with the conserved quantities of the integrable system. We discuss a concrete experimental realization to study this effect using matterwave interferometry and many-body revivals on an atom chip.

  6. Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index

    International Nuclear Information System (INIS)

    Shi Chengyu; Penagaricano, Jose; Papanikolaou, Niko

    2008-01-01

    Intensity modulated radiotherapy (IMRT) is an advanced treatment technology for radiation therapy. There are several treatment planning systems (TPS) that can generate IMRT plans. These plans may show different inhomogeneity indices to the planning target volume (PTV) and integral dose to organs at risk (OAR). In this study, we compared clinical cases covering different anatomical treatment sites, including head and neck, brain, lung, prostate, pelvis, and cranio-spinal axis. Two treatment plans were developed for each case using Pinnacle 3 and helical tomotherapy (HT) TPS. The inhomogeneity index of the PTV and the non-tumor integral dose (NTID) were calculated and compared for each case. Despite the difference in the number of effective beams, in several cases, NTID did not increase from HT as compared to the step-and-shoot delivery method. Six helical tomotherapy treatment plans for different treatment sites have been analyzed and compared against corresponding step-and-shoot plans generated with the Pinnacle 3 planning system. Results show that HT may produce plans with smaller integral doses to healthy organs, and fairly homogeneous doses to the target as compared to linac-based step-and-shoot IMRT planning in special treatment site such as cranio-spinal

  7. Integral Dose and Radiation-Induced Secondary Malignancies: Comparison between Stereotactic Body Radiation Therapy and Three-Dimensional Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Stefano G. Masciullo

    2012-11-01

    Full Text Available The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID in stereotactic body radiation therapy (SBRT with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT, estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED on the target (BED = 76Gy10. Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05. Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002, secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001. This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

  8. The repair of low dose UV light-induced damage to human skin DNA in condition of trace amount Mg 2+

    Science.gov (United States)

    Gao, Fang; Guo, Zhouyi; Zheng, Changchun; Wang, Rui; Liu, Zhiming; Meng, Pei; Zhai, Juan

    2008-12-01

    Ultraviolet light-induced damage to human skin DNA was widely investigated. The primary mechanism of this damage contributed to form cyclobutane pyrimidine dimmers (CPDs). Although the distribution of UV light-induced CPDs within a defined sequence is similar, the damage in cellular environment which shields the nuclear DNA was higher than that in organism in apparent dose. So we use low UVB light as main study agent. Low dose UV-irradiated HDF-a cells (Human Dermal Fibroblasts-adult cells) which is weaker than epidermic cells were cultured with DMEM at different trace amount of Mg2+ (0mmol/L , 0.1mmol/L , 0.2mmol/L, 0.4mmol/L, 0.8mmol/L, 1.2mmol/L) free-serum DMEM and the repair of DNA strands injured were observed. Treat these cells with DNA strand breaks detection, photoproducts detection and the repair of photoproducts detection. Then quantitate the role of trace amount Mg2+ in repair of UV light-induced damage to human skin. The experiment results indicated that epidermic cells have capability of resistance to UV-radiation at a certain extent. And Mg2+ can regulate the UV-induced damage repair and relative vitality. It can offer a rationale and experiment data to relieve UV light-induced skin disease.

  9. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  10. Thermoluminescent accident dose reader with photodiode; Termoluminiscencni litalnik akcidentnih doz s fotodiodo

    Energy Technology Data Exchange (ETDEWEB)

    Miklavzic, U; Mihelic, M [Institut Jozef Stefan, Ljubljana (Yugoslavia)

    1982-07-01

    The field version of TL reader for accident dose region 0.01-20 Gy is described. For light detection, the thermostated photodiode was used permitting measurements at the ambient temperatures from -20 C degrees to 50 C degrees, and a new mode of the glow curve integration. Results can be presented as integral or peak values of the glow curve. The reader was adapted for dosemeters IJS-TLD08 from sintered CaF2:Mn pellets. (author)

  11. Recovering star formation histories: Integrated-light analyses vs. stellar colour-magnitude diagrams

    Science.gov (United States)

    Ruiz-Lara, T.; Pérez, I.; Gallart, C.; Alloin, D.; Monelli, M.; Koleva, M.; Pompei, E.; Beasley, M.; Sánchez-Blázquez, P.; Florido, E.; Aparicio, A.; Fleurence, E.; Hardy, E.; Hidalgo, S.; Raimann, D.

    2015-11-01

    Context. Accurate star formation histories (SFHs) of galaxies are fundamental for understanding the build-up of their stellar content. However, the most accurate SFHs - those obtained from colour-magnitude diagrams (CMDs) of resolved stars reaching the oldest main-sequence turnoffs (oMSTO) - are presently limited to a few systems in the Local Group. It is therefore crucial to determine the reliability and range of applicability of SFHs derived from integrated light spectroscopy, as this affects our understanding of unresolved galaxies from low to high redshift. Aims: We evaluate the reliability of current full spectral fitting techniques in deriving SFHs from integrated light spectroscopy by comparing SFHs from integrated spectra to those obtained from deep CMDs of resolved stars. Methods: We have obtained a high signal-to-noise (S/N ~ 36.3 per Å) integrated spectrum of a field in the bar of the Large Magellanic Cloud (LMC) using EFOSC2 at the 3.6-metre telescope at La Silla Observatory. For this same field, resolved stellar data reaching the oMSTO are available. We have compared the star formation rate (SFR) as a function of time and the age-metallicity relation (AMR) obtained from the integrated spectrum using STECKMAP, and the CMD using the IAC-star/MinnIAC/IAC-pop set of routines. For the sake of completeness we also use and discuss other synthesis codes (STARLIGHT and ULySS) to derive the SFR and AMR from the integrated LMC spectrum. Results: We find very good agreement (average differences ~4.1%) between the SFR (t) and the AMR obtained using STECKMAP on the integrated light spectrum, and the CMD analysis. STECKMAP minimizes the impact of the age-metallicity degeneracy and has the advantage of preferring smooth solutions to recover complex SFHs by means of a penalized χ2. We find that the use of single stellar populations (SSPs) to recover the stellar content, using for instance STARLIGHT or ULySS codes, hampers the reconstruction of the SFR (t) and AMR

  12. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  13. Integration of real-time 3D capture, reconstruction, and light-field display

    Science.gov (United States)

    Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao

    2015-03-01

    Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.

  14. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  15. Non-invasive plant growth measurements for detection of blue-light dose response of stem elongation in Chrysanthemum morifolium

    DEFF Research Database (Denmark)

    Kjær, Katrine Heinsvig

    2012-01-01

    . In the present study a non-invasive plant growth sensor (PlantEye, Phenospex B.V, Heerlen, NL) was tested in analysing changes in diurnal stem elongation patterns and plant height in response to the spectral quality of the light environment. Plants were grown in four different LED supplemental lighting...... treatments with 0%, 12.5%, 18.5% and 22.5% blue light under greenhouse conditions in winter (18 h day/4 h night). The non-invasive measurements were carried out automatically every four hour with three repetitions, and supported by manual measurements of plant height every third day. A strong linear relation...... between the non-invasive measurements and manual measurements of plant height was achieved, and a blue-light dose-response showing a decrease in plant height in relation to an increase in blue light was demonstrated. However, the non-invasive plant growth sensor was not able to distinguish between diurnal...

  16. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    Science.gov (United States)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  17. Semipolar InGaN quantum-well laser diode with integrated amplifier for visible light communications

    KAUST Repository

    Shen, Chao

    2018-02-14

    GaN-based semiconductor optical amplifier (SOA) and its integration with laser diode (LD) is an essential building block yet to be demonstrated for III-nitride photonic integrated circuits (PICs) at visible wavelength. This paper presents the InGaN/GaN quantum well (QW) based dual-section LD consisting of integrated amplifier and laser gain regions fabricated on a semipolar GaN substrate. The threshold current in the laser gain region was favorably reduced from 229mA to 135mA at SOA driving voltages, VSOA, of 0V and 6.25V, respectively. The amplification effect was measured based on a large gain of 5.7 dB at VSOA = 6.25V from the increased optical output power of 8.2 mW to 30.5 mW. Such integrated amplifier can be modulated to achieve Gbps data communication using on-off keying technique. The monolithically integrated amplifier-LD paves the way towards the III-nitride on-chip photonic system, providing a compact, low-cost, and multi-functional solution for applications such as smart lighting and visible light communications.

  18. Semipolar InGaN quantum-well laser diode with integrated amplifier for visible light communications

    KAUST Repository

    Shen, Chao; Ng, Tien Khee; Lee, Changmin; Nakamura, Shuji; Speck, James S.; DenBaars, Steven P.; Alyamani, Ahmed Y.; El-Desouki, Munir M.; Ooi, Boon S.

    2018-01-01

    GaN-based semiconductor optical amplifier (SOA) and its integration with laser diode (LD) is an essential building block yet to be demonstrated for III-nitride photonic integrated circuits (PICs) at visible wavelength. This paper presents the InGaN/GaN quantum well (QW) based dual-section LD consisting of integrated amplifier and laser gain regions fabricated on a semipolar GaN substrate. The threshold current in the laser gain region was favorably reduced from 229mA to 135mA at SOA driving voltages, VSOA, of 0V and 6.25V, respectively. The amplification effect was measured based on a large gain of 5.7 dB at VSOA = 6.25V from the increased optical output power of 8.2 mW to 30.5 mW. Such integrated amplifier can be modulated to achieve Gbps data communication using on-off keying technique. The monolithically integrated amplifier-LD paves the way towards the III-nitride on-chip photonic system, providing a compact, low-cost, and multi-functional solution for applications such as smart lighting and visible light communications.

  19. Localization of fluorescently labeled structures in frozen-hydrated samples using integrated light electron microscopy.

    Science.gov (United States)

    Faas, F G A; Bárcena, M; Agronskaia, A V; Gerritsen, H C; Moscicka, K B; Diebolder, C A; van Driel, L F; Limpens, R W A L; Bos, E; Ravelli, R B G; Koning, R I; Koster, A J

    2013-03-01

    Correlative light and electron microscopy is an increasingly popular technique to study complex biological systems at various levels of resolution. Fluorescence microscopy can be employed to scan large areas to localize regions of interest which are then analyzed by electron microscopy to obtain morphological and structural information from a selected field of view at nm-scale resolution. Previously, an integrated approach to room temperature correlative microscopy was described. Combined use of light and electron microscopy within one instrument greatly simplifies sample handling, avoids cumbersome experimental overheads, simplifies navigation between the two modalities, and improves the success rate of image correlation. Here, an integrated approach for correlative microscopy under cryogenic conditions is presented. Its advantages over the room temperature approach include safeguarding the native hydrated state of the biological specimen, preservation of the fluorescence signal without risk of quenching due to heavy atom stains, and reduced photo bleaching. The potential of cryo integrated light and electron microscopy is demonstrated for the detection of viable bacteria, the study of in vitro polymerized microtubules, the localization of mitochondria in mouse embryonic fibroblasts, and for a search into virus-induced intracellular membrane modifications within mammalian cells. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Effects of read-out light sources and ambient light on radiochromic film

    International Nuclear Information System (INIS)

    Butson, Martin J.; Yu, Peter K.N.; Metcalfe, Peter E.

    1998-01-01

    Both read-out light sources and ambient light sources can produce a marked effect on coloration of radiochromic film. Fluorescent, helium neon laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose coloration of 660 cGy h -1 , 4.3 cGy h -1 , 1.7 cGy h -1 and 2.6 cGy h -1 respectively. Direct sunlight, fluorescent light and incandescent ambient light produce an equivalent dose coloration of 30 cGy h -1 , 18 cGy h -1 and 0 cGy h -1 respectively. Continuously on, fluorescent light sources should not be used for film optical density evaluation and minimal exposure to any light source will increase the accuracy of results. (author)

  1. Integrative Multi-Spectral Sensor Device for Far-Infrared and Visible Light Fusion

    Science.gov (United States)

    Qiao, Tiezhu; Chen, Lulu; Pang, Yusong; Yan, Gaowei

    2018-06-01

    Infrared and visible light image fusion technology is a hot spot in the research of multi-sensor fusion technology in recent years. Existing infrared and visible light fusion technologies need to register before fusion because of using two cameras. However, the application effect of the registration technology has yet to be improved. Hence, a novel integrative multi-spectral sensor device is proposed for infrared and visible light fusion, and by using the beam splitter prism, the coaxial light incident from the same lens is projected to the infrared charge coupled device (CCD) and visible light CCD, respectively. In this paper, the imaging mechanism of the proposed sensor device is studied with the process of the signals acquisition and fusion. The simulation experiment, which involves the entire process of the optic system, signal acquisition, and signal fusion, is constructed based on imaging effect model. Additionally, the quality evaluation index is adopted to analyze the simulation result. The experimental results demonstrate that the proposed sensor device is effective and feasible.

  2. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  3. Integrated vehicle-based safety systems light-vehicle field operational test key findings report.

    Science.gov (United States)

    2011-01-01

    "This document presents key findings from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michigan Transportat...

  4. Integrable light-cone lattice discretizations from the universal R-matrix

    International Nuclear Information System (INIS)

    Meneghelli, C.

    2015-04-01

    Our goal is to develop a more general scheme for constructing integrable lattice regularisations of integrable quantum field theories. Considering the affine Toda theories as examples, we show how to construct such lattice regularisations using the representation theory of quantum affine algebras. This requires us to clarify in particular the relations between the light-cone approach to integrable lattice models and the representation theory of quantum affine algebras. Both are found to be related in a very natural way, suggesting a general scheme for the construction of generalised Baxter Q-operators. One of the main difficulties we need to deal with is coming from the infinite-dimensionality of the relevant families of representations. It is handled by means of suitable renormalisation prescriptions defining what may be called the modular double of quantum affine algebras. This framework allows us to give a representation-theoretic proof of finite-difference equations generalising the Baxter equation.

  5. Assessment of diurnal systemic dose of agrochemicals in regulatory toxicity testing--an integrated approach without additional animal use.

    Science.gov (United States)

    Saghir, Shakil A; Bartels, Michael J; Rick, David L; McCoy, Alene T; Rasoulpour, Reza J; Ellis-Hutchings, Robert G; Sue Marty, M; Terry, Claire; Bailey, Jason P; Billington, Richard; Bus, James S

    2012-07-01

    Integrated toxicokinetics (TK) data provide information on the rate, extent and duration of systemic exposure across doses, species, strains, gender, and life stages within a toxicology program. While routine for pharmaceuticals, TK assessments of non-pharmaceuticals are still relatively rare, and have never before been included in a full range of guideline studies for a new agrochemical. In order to better understand the relationship between diurnal systemic dose (AUC(24h)) and toxicity of agrochemicals, TK analyses in the study animals is now included in all short- (excluding acute), medium- and long-term guideline mammalian toxicity studies including reproduction/developmental tests. This paper describes a detailed procedure for the implementation of TK in short-, medium- and long-term regulatory toxicity studies, without the use of satellite animals, conducted on three agrochemicals (X11422208, 2,4-D and X574175). In these studies, kinetically-derived maximum doses (KMD) from short-term studies instead of, or along with, maximum tolerated doses (MTD) were used for the selection of the high dose in subsequent longer-term studies. In addition to leveraging TK data to guide dose level selection, the integrated program was also used to select the most appropriate method of oral administration (i.e., gavage versus dietary) of test materials for rat and rabbit developmental toxicity studies. The integrated TK data obtained across toxicity studies (without the use of additional/satellite animals) provided data critical to understanding differences in response across doses, species, strains, sexes, and life stages. Such data should also be useful in mode of action studies and to improve human risk assessments. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Integrated doses calculation in evacuation scenarios of the neutron generator facility at Missouri S&T

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manish K.; Alajo, Ayodeji B., E-mail: alajoa@mst.edu

    2016-08-11

    Any source of ionizing radiations could lead to considerable dose acquisition to individuals in a nuclear facility. Evacuation may be required when elevated levels of radiation is detected within a facility. In this situation, individuals are more likely to take the closest exit. This may not be the most expedient decision as it may lead to higher dose acquisition. The strategy followed in preventing large dose acquisitions should be predicated on the path that offers least dose acquisition. In this work, the neutron generator facility at Missouri University of Science and Technology was analyzed. The Monte Carlo N-Particle (MCNP) radiation transport code was used to model the entire floor of the generator's building. The simulated dose rates in the hallways were used to estimate the integrated doses for different paths leading to exits. It was shown that shortest path did not always lead to minimum dose acquisition and the approach was successful in predicting the expedient path as opposed to the approach of taking the nearest exit.

  7. Integral Inherently Safe Light Water Reactor (I2S-LWR)

    International Nuclear Information System (INIS)

    Petrovic, Bojan; Memmott, Matthew; Boy, Guy; Charit, Indrajit; Manera, Annalisa; Downar, Thomas; Lee, John; Muldrow, Lycurgus; Upadhyaya, Belle; Hines, Wesley; Haghighat, Alierza

    2017-01-01

    This final report summarizes results of the multi-year effort performed during the period 2/2013- 12/2016 under the DOE NEUP IRP Project ''Integral Inherently Safe Light Water Reactors (I 2 S-LWR)''. The goal of the project was to develop a concept of a 1 GWe PWR with integral configuration and inherent safety features, at the same time accounting for lessons learned from the Fukushima accident, and keeping in mind the economic viability of the new concept. Essentially (see Figure 1-1) the project aimed to implement attractive safety features, typically found only in SMRs, to a larger power (1 GWe) reactor, to address the preference of some utilities in the US power market for unit power level on the order of 1 GWe.

  8. Preliminary evidence that light through the eyelids can suppress melatonin and phase shift dim light melatonin onset.

    Science.gov (United States)

    Figueiro, Mariana G; Rea, Mark S

    2012-05-07

    A previous study reported a method for measuring the spectral transmittance of individual human eyelids. A prototype light mask using narrow-band "green" light (λmax = 527 nm) was used to deliver light through closed eyelids in two within-subjects studies. The first study investigated whether an individual-specific light dose could suppress melatonin by 40% through the closed eyelid without disrupting sleep. The light doses were delivered at three times during the night: 1) beginning (while subjects were awake), 2) middle (during rapid eye movement (REM) sleep), and 3) end (during non-REM sleep). The second study investigated whether two individual-specific light doses expected to suppress melatonin by 30% and 60% and delivered through subjects' closed eyelids before the time of their predicted minimum core body temperature would phase delay the timing of their dim light melatonin onset (DLMO). Compared to a dark control night, light delivered through eyelids suppressed melatonin by 36% (p = 0.01) after 60-minute light exposure at the beginning, 45% (p = 0.01) at the middle, and 56% (p light levels 1 and 2, respectively. These studies demonstrate that individual-specific doses of light delivered through closed eyelids can suppress melatonin and phase shift DLMO and may be used to treat circadian sleep disorders.

  9. A service platform architecture design towards a light integration of heterogeneous systems in the wellbeing domain.

    Science.gov (United States)

    Yang, Yaojin; Ahtinen, Aino; Lahteenmaki, Jaakko; Nyman, Petri; Paajanen, Henrik; Peltoniemi, Teijo; Quiroz, Carlos

    2007-01-01

    System integration is one of the major challenges for building wellbeing or healthcare related information systems. In this paper, we are going to share our experiences on how to design a service platform called Nuadu service platform, for providing integrated services in occupational health promotion and health risk management through two heterogeneous systems. Our design aims for a light integration covering the layers, from data through service up to presentation, while maintaining the integrity of the underlying systems.

  10. CMOS On-Chip Optoelectronic Neural Interface Device with Integrated Light Source for Optogenetics

    International Nuclear Information System (INIS)

    Sawadsaringkarn, Y; Kimura, H; Maezawa, Y; Nakajima, A; Kobayashi, T; Sasagawa, K; Noda, T; Tokuda, T; Ohta, J

    2012-01-01

    A novel optoelectronic neural interface device is proposed for target applications in optogenetics for neural science. The device consists of a light emitting diode (LED) array implemented on a CMOS image sensor for on-chip local light stimulation. In this study, we designed a suitable CMOS image sensor equipped with on-chip electrodes to drive the LEDs, and developed a device structure and packaging process for LED integration. The prototype device produced an illumination intensity of approximately 1 mW with a driving current of 2.0 mA, which is expected to be sufficient to activate channelrhodopsin (ChR2). We also demonstrated the functions of light stimulation and on-chip imaging using a brain slice from a mouse as a target sample.

  11. Comparsion of light dose on topical ALA-mediated photodynamic therapy for DMBA-induced hamster buccal pouch premalignant lesions

    Science.gov (United States)

    Yang, Deng-Fu; Tseng, Meng-Ke; Liu, Chung-Ji; Hsu, Yih-Chih

    2012-03-01

    Oral cancer has becomes the most prominent male cancer disease due to the local betel nut chewing habit combing with smoking and alcohol-drinking lifestyle. In order to minimize the systemic phototoxic effect of 5-aminolevulinic acid (ALA), this study was designed to use a topical ALA-mediated PDT for treatment of DMBA-induced hamster buccal pouch cancerous lesions. DMBA was applied to one of the buccal pouches of hamsters thrice a week for 8 to 10 weeks. Precancerous lesions were induced and proven by histological examination. These DMBA-induced cancerous lesions were used for testing the efficacy of topical ALA -mediated PDT. We found that ALA reached its peak level in cancerous lesions about 2.5 hrs after topical application of ALA gel. The precancerous lesions in hamsters were then treated with topical ALA -mediated PDT with light exposure dose of 75 and 100 J/cm2 using LED 635 nm Wonderlight device. It is suggesting that optimization of the given light dose is critical to the success of PDT results.

  12. Adaptation of mechano-graphy to the measurement of integrated doses (1962); Adaptation de la mecanographie pour la comptabilisation des doses integrees (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Tabardel-Brian, R; Dulau, J [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1962-07-01

    Because of the increasing number of workers exposed to nuclear radiation, and with a view to avoiding doses above the maximum permissible dose for these workers, it was necessary to find a system whereby the total irradiation assimilated during periods of 3 and 12 consecutive months could be known and circulated rapidly, within 48 hours. The method chosen for this requires the services of the Mechano-graphic service of the Marcoule Centre. The present article describes the mechanical data processing solution to this problem. (authors) [French] Devant le nombre croissant de travailleurs appeles a etre exposes a une irradiation d'origine nucleaire et avec le souci constant d'eviter les depassements de Dose Maximum Admissible a ces agents, il convenait de trouver un systeme de diffusion de doses integrees capable de nous renseigner, dans un delai de 48 h, sur le capital irradiation integre au cours des periodes 3 mois et 12 mois consecutifs. Le mode de diffusion retenu fait appel aux services de l'Atelier Mecanographie du Centre de Marcoule. Le present rapport expose la solution mecanographique apportee a ce probleme. (auteurs)

  13. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  14. Integrated vehicle-based safety systems light-vehicle field operational test, methodology and results report.

    Science.gov (United States)

    2010-12-01

    "This document presents the methodology and results from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michi...

  15. Levels of daily light doses under changed day-night cycles regulate temporal segregation of photosynthesis and N2 Fixation in the cyanobacterium Trichodesmium erythraeum IMS101.

    Science.gov (United States)

    Cai, Xiaoni; Gao, Kunshan

    2015-01-01

    While the diazotrophic cyanobacterium Trichodesmium is known to display inverse diurnal performances of photosynthesis and N2 fixation, such a phenomenon has not been well documented under different day-night (L-D) cycles and different levels of light dose exposed to the cells. Here, we show differences in growth, N2 fixation and photosynthetic carbon fixation as well as photochemical performances of Trichodesmium IMS101 grown under 12L:12D, 8L:16D and 16L:8D L-D cycles at 70 μmol photons m-2 s-1 PAR (LL) and 350 μmol photons m-2 s-1 PAR (HL). The specific growth rate was the highest under LL and the lowest under HL under 16L:8D, and it increased under LL and decreased under HL with increased levels of daytime light doses exposed under the different light regimes, respectively. N2 fixation and photosynthetic carbon fixation were affected differentially by changes in the day-night regimes, with the former increasing directly under LL with increased daytime light doses and decreased under HL over growth-saturating light levels. Temporal segregation of N2 fixation from photosynthetic carbon fixation was evidenced under all day-night regimes, showing a time lag between the peak in N2 fixation and dip in carbon fixation. Elongation of light period led to higher N2 fixation rate under LL than under HL, while shortening the light exposure to 8 h delayed the N2 fixation peaking time (at the end of light period) and extended it to night period. Photosynthetic carbon fixation rates and transfer of light photons were always higher under HL than LL, regardless of the day-night cycles. Conclusively, diel performance of N2 fixation possesses functional plasticity, which was regulated by levels of light energy supplies either via changing light levels or length of light exposure.

  16. Application of the Monte Carlo integration method in calculations of dose distributions in HDR-Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baltas, D; Geramani, K N; Ioannidis, G T; Kolotas, C; Zamboglou, N [Strahlenklinik, Stadtische Kliniken Offenbach, Offenbach (Germany); Giannouli, S [Department of Electrical and Computer Engineering, National Technical University of Athens, Athens (Greece)

    1999-12-31

    Source anisotropy is a very important factor in brachytherapy quality assurance of high dose rate HDR Ir 192 afterloading stepping sources. If anisotropy is not taken into account then doses received by a brachytherapy patient in certain directions can be in error by a clinically significant amount. Experimental measurements of anisotropy are very labour intensive. We have shown that within acceptable limits of accuracy, Monte Carlo integration (MCI) of a modified Sievert integral (3D generalisation) can provide the necessary data within a much shorter time scale than can experiments. Hence MCI can be used for routine quality assurance schedules whenever a new design of HDR or PDR Ir 192 is used for brachytherapy afterloading. Our MCI calculation results are comparable with published experimental data and Monte Carlo simulation data for microSelectron and VariSource Ir 192 sources. We have shown not only that MCI offers advantages over alternative numerical integration methods, but also that treating filtration coefficients as radial distance-dependent functions improves Sievert integral accuracy at low energies. This paper also provides anisotropy data for three new Ir 192 sources, one for microSelectron-HDR and two for the microSelectron-PDR, for which data currently is not available. The information we have obtained in this study can be incorporated into clinical practice.

  17. Characterisation of blue-light stimulated luminescence components in different quartz samples: Implications for dose measurement

    DEFF Research Database (Denmark)

    Jain, M.; Murray, A.S.; Bøtter-Jensen, L.

    2003-01-01

    -aliquot dose-evaluation protocols seem to be relatively free of complications when applied to quartz dominated by the fast OSL component coming from 325degreesC TL region, but this may not be true for quartz in which other components are more significant. An adequate understanding of how different OSL...... results from measurement of (a) sensitisation, (b) thermal stability, (c) recuperation, and (d) infrared response as a function of stimulation temperature from 3 different samples of sedimentary quartz selected on the basis of relative OSL contribution from different blue light stimulated linearly...

  18. Integrated-light spectroscopy of globular clusters at the infrared Ca II lines

    Science.gov (United States)

    Armandroff, Taft E.; Zinn, Robert

    1988-01-01

    Integrated-light spectroscopy has been obtained for 27 globular clusters at the Ca II IR triplet. Line strengths and radial velocities have been measured from the spectra. For the well-studied clusters in the sample, the strength of the Ca II lines is very well correlated with previous metallicity estimates. Thus, the triplet is useful as a metallicity indicator in globular cluster integrated-light spectra. The greatly reduced effect of interstellar extinction at these wavelengths (compared to the blue region of the spectrum) has permitted observations of some of the most heavily reddened clusters in the Galaxy. For several such clusters, the Ca II triplet metallicities are in poor agreement with metallicity estimates from IR photometry by Malkan (1981). The strength of an interstellar band at 8621A has been used to estimate the amount of extinction towards these clusters. Using the new metallicity and radial-velocity data, the metallicity distribution, kinematics, and spatial distribution of the disk globular cluster system have been analyzed. Results very similar to those of Zinn (1985) have been found. The relation of the disk globulars to the stellar thick disk is discussed.

  19. Functions and requirements for the light duty utility arm integrated system

    International Nuclear Information System (INIS)

    Kiebel, G.R.

    1996-01-01

    The Light Duty Utility Arm (LDUA) Integrated System is a mobile robotic system designed to remotely deploy and operate a variety of tools in uninhabitable underground radiological and hazardous waste storage tanks. The system primarily provides a means to inspect, survey, monitor, map and/or obtain specific waste and waste tank data in support of the Tank Waste Remediation System (TWRS) mission at Hanford and remediation programs at other U.S. Department of Energy (DOE) sites

  20. Integrated vehicle-based safety systems (IVBSS) : light vehicle platform field operational test data analysis plan.

    Science.gov (United States)

    2009-12-22

    This document presents the University of Michigan Transportation Research Institutes plan to : perform analysis of data collected from the light vehicle platform field operational test of the : Integrated Vehicle-Based Safety Systems (IVBSS) progr...

  1. SU-E-T-166: Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient

    Energy Technology Data Exchange (ETDEWEB)

    Al-Basheer, A; Hunag, J; Kaminski, J; Dasher, B; Howington, J; Stewart, J; Martin, D; Kong, F; Jin, J [Georgia Regents University, Augusta, GA (Georgia)

    2014-06-01

    Purpose: Volumetric Modulated Arc Therapy (VMAT) usually achieves higher conformity of radiation doses to targets and less delivery time than Intensity Modulated Radiation Therapy (IMRT). We hypothesized that VMAT will increase integral dose (ID) to patients which will decrease the count of white blood count (WBC) lymphocytes, and consequently has a subsequent impact on the immune system. The purpose of this study is to evaluate the ID to patients undergoing IMRT and VMAT for Head and Neck cancers and its impact on the immune system. Methods: As a pilot study, 30 head and neck patients who received 9-fields IMRT or 3-arcs Radip-Arcbased VMAT were included in this study. Ten of these patients who received the VMAT plans were re-planned using IMRT with the same objectives. ID was calculated for all cases. All patients also had a baseline WBC obtained prior to treatment, and 3 sets of labs drawn during the course of radiation treatment. Results: For the 10 re-planned patients, the mean ID was 13.3 Gy/voxel (range 10.2–17.5 Gy/voxel) for the 9-fields IMRT plans, and was 15.9 Gy/voxel (range 12.4-20.9 Gy/voxel) for the 3-Arc VMAT plan (p=0.01). The integral dose was significant correlated with reducing WBC count during RT even when controlling for concurrent chemotherapy (R square =0.56, p=0.008). Conclusion: Although VMAT can deliver higher radiation dose conformality to targets, this benefit is achieved generally at the cost of greater integral doses to normal tissue outside the planning target volume (PTV). Lower WBC counts during RT were associated with higher Integral doses even when controlling for concurrent chemotherapy. This study is ongoing in our Institution to exam the impact of integral doses and WBC on overall survival.

  2. Accompanying of parameters of color, gloss and hardness on polymeric films coated with pigmented inks cured by different radiation doses of ultraviolet light

    International Nuclear Information System (INIS)

    Gonçalves Bardi, Marcelo Augusto; Brocardo Machado, Luci Diva

    2012-01-01

    In the search for alternatives to traditional paint systems solvent-based, the curing process of polymer coatings by ultraviolet light (UV) has been widely studied and discussed, especially because of their high content of solids and null emission of VOC. In UV-curing technology, organic solvents are replaced by reactive diluents, such as monomers. This paper aims to investigate variations on color, gloss and hardness of print inks cured by different UV radiation doses. The ratio pigment/clear coating was kept constant. The clear coating presented higher average values for König hardness than pigmented ones, indicating that UV-light absorption has been reduced by the presence of pigments. Besides, they have indicated a slight variation in function of cure degree for the studied radiation doses range. The gloss loss related to UV light exposition allows inferring that some degradation occurred at the surface of print ink films. - Highlights: ► Color, gloss and hardness are directly influenced by the different pigments. ► Clear coating analysis indicates reduction on UV-light absorption. ► Color and gloss indices indicated aeration in function of cure degree.

  3. Safety of dose escalation by simultaneous integrated boosting radiation dose within the primary tumor guided by 18FDG-PET/CT for esophageal cancer

    International Nuclear Information System (INIS)

    Yu, Wen; Cai, Xu-Wei; Liu, Qi; Zhu, Zheng-Fei; Feng, Wen; Zhang, Qin; Zhang, Ying-Jian; Yao, Zhi-Feng; Fu, Xiao-Long

    2015-01-01

    Purpose: To observe the safety of selective dose boost to the pre-treatment high 18 F-deoxyglucose (FDG) uptake areas of the esophageal GTV. Methods: Patients with esophageal squamous cell carcinoma were treated with escalating radiation dose of 4 levels, with a simultaneous integrated boost (SIB) to the pre-treatment 50% SUVmax area of the primary tumor. Patients received 4 monthly cycles of cisplatin and fluorouracil. Dose-limiting toxicity (DLT) was defined as any Grade 3 or higher acute toxicities causing continuous interruption of radiation for over 1 week. Results: From April 2012 to February 2014, dose has been escalated up to LEVEL 4 (70 Gy). All of the 25 patients finished the prescribed dose without DLT, and 10 of them developed Grade 3 acute esophagitis. One patient of LEVEL 2 died of esophageal hemorrhage within 1 month after completion of radiotherapy, which was not definitely correlated with treatment yet. Late toxicities remained under observation. With median follow up of 8.9 months, one-year overall survival and local control was 69.2% and 77.4%, respectively. Conclusions: Dose escalation in esophageal cancer based on 18 FDG-PET/CT has been safely achieved up to 70 Gy using the SIB technique. Acute toxicities were well tolerated, whereas late toxicities and long-term outcomes deserved further observation

  4. AMIC: an expandable integrated analog front-end for light distribution moments analysis

    Energy Technology Data Exchange (ETDEWEB)

    Spaggiari, M; Herrero, V; Lerche, C W; Aliaga, R; Monzo, J M; Gadea, R, E-mail: michele.spaggiari@gmail.com [Instituto de Instrumentacion para Imagen Molecular (I3M), Universidad Politecnica de Valencia, Camino de Vera, 46022, Valencia (Spain)

    2011-01-15

    In this article we introduce AMIC (Analog Moments Integrated Circuit), a novel analog Application Specific Integrated Circuit (ASIC) front-end for Positron Emission Tomography (PET) applications. Its working principle is based on mathematical analysis of light distribution through moments calculation. Each moment provides useful information about light distribution, such as energy, position, depth of interaction, skewness (deformation due to border effect) etc. A current buffer delivers a copy of each input current to several processing blocks. The current preamplifier is designed in order to achieve unconditional stability under high input capacitance, thus allowing the use of both Photo-Multiplier Tubes (PMT) and Silicon Photo-Multipliers (SiPM). Each processing block implements an analog current filtering by multiplying each input current by a programmable 8-bit coefficient. The latter is implemented through a high linear MOS current divider ladder, whose high sensitivity to variations in output voltages requires the integration of an extremely stable fully differential current collector. Output currents are then summed and sent to the output stage, that provides both a buffered output current and a linear rail-to-rail voltage for further digitalization. Since computation is purely additive, the 64 input channels of AMIC do not represent a limitation in the number of the detector's outputs. Current outputs of various AMIC structures can be combined as inputs of a final AMIC, thus providing a fully expandable structure. In this version of AMIC, 8 programmable blocks for moments calculation are integrated, as well as an I2C interface in order to program every coefficient. Extracted layout simulation results demonstrate that the information provided by moment calculation in AMIC helps to improve tridimensional positioning of the detected event. A two-detector test-bench is now being used for AMIC prototype characterization and preliminary results are presented.

  5. Integrated technique for assessing environmental dose of radioactive waste storage installation

    Energy Technology Data Exchange (ETDEWEB)

    Bor-Jing Chang; Chien-Liang Shih; Ing-Jane Chen [Institute of Nuclear Energy Research, Lungtan, Taiwan (China); Ren-Dih Sheu; Shiang-Huei Jiang [National Tsing Hua University, Hsinchu, Taiwan (China); Shu-Jun Chang [Nuclear Science and Technology Association, Taiwan (China); Ruei-Ying Liao; Pei Yu; Chin-Yi Huang [Taiwan Power Company, Taipei, Taiwan (China)

    2000-05-01

    The ability to accurately predict exposure rates at large distances from a gamma radiation source is becoming increasingly important. This is because that the related regulation for the control of radiation levels in and around nuclear facilities becomes more stringent. Since the continuous increase of the radwaste storage capacity requirement on site, the requirement of a more realistic evaluation is very necessary. Those doses are usually at past time evaluated by QADCG/INER-2 code for direct dose and by SKYSHINE-III code for skyshine dose in which evaluation were over conservatively considered. This study is to update the evaluation code package accompanied with adequate methodology and to establish integrated analysis procedure. Thereafter, radiation doses can be accurately calculated in a reasonably conservative way. The purpose of the investigation is divided into three categories. First, SPECTRUM-506 is used instead of SPECTUM. Nuclide databases are enlarged from 100 up to 506. And the operation is ported to personal computer. Secondly, the QADCG/INER-3 code is developed to enhance the original QADCG/INER-2 code. The most important difference is the use of the geometric progression (GP) fitting function for the gamma-ray buildup factor. SKYSHINE-III code is replaced by McSKY and SKYDOSE codes. They are well benchmarked by using the Monte Carlo code MCNP and sensitive parameters are detailed investigated. Thirdly, the well developed analysis procedure is applicable for nuclear utility radwaste storage sites. Finally, the case studies were performed by using those packages to assess the radiological impact of utility radwaste storage site. The results are verified in detail by using Monte Carlo code MCNP and the results seems pretty consistent from both method. (author)

  6. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  7. System responses to equal doses of photosynthetically usable radiation of blue, green, and red light in the marine diatom Phaeodactylum tricornutum.

    Directory of Open Access Journals (Sweden)

    Kristin Collier Valle

    Full Text Available Due to the selective attenuation of solar light and the absorption properties of seawater and seawater constituents, free-floating photosynthetic organisms have to cope with rapid and unpredictable changes in both intensity and spectral quality. We have studied the transcriptional, metabolic and photo-physiological responses to light of different spectral quality in the marine diatom Phaeodactylum tricornutum through time-series studies of cultures exposed to equal doses of photosynthetically usable radiation of blue, green and red light. The experiments showed that short-term differences in gene expression and profiles are mainly light quality-dependent. Transcription of photosynthesis-associated nuclear genes was activated mainly through a light quality-independent mechanism likely to rely on chloroplast-to-nucleus signaling. In contrast, genes encoding proteins important for photoprotection and PSII repair were highly dependent on a blue light receptor-mediated signal. Changes in energy transfer efficiency by light-harvesting pigments were spectrally dependent; furthermore, a declining trend in photosynthetic efficiency was observed in red light. The combined results suggest that diatoms possess a light quality-dependent ability to activate photoprotection and efficient repair of photodamaged PSII. In spite of approximately equal numbers of PSII-absorbed quanta in blue, green and red light, the spectral quality of light is important for diatom responses to ambient light conditions.

  8. A Planar, Chip-Based, Dual-Beam Refractometer Using an Integrated Organic Light Emitting Diode (OLED) Light Source and Organic Photovoltaic (OPV) Detectors

    Science.gov (United States)

    Ratcliff, Erin L.; Veneman, P. Alex; Simmonds, Adam; Zacher, Brian; Huebner, Daniel

    2010-01-01

    We present a simple chip-based refractometer with a central organic light emitting diode (OLED) light source and two opposed organic photovoltaic (OPV) detectors on an internal reflection element (IRE) substrate, creating a true dual-beam sensor platform. For first-generation platforms, we demonstrate the use of a single heterojunction OLED based on electroluminescence emission from an Alq3/TPD heterojunction (tris-(8-hydroxyquinoline)aluminum/N,N′-Bis(3-methylphenyl)-N,N′-diphenylbenzidine) and light detection with planar heterojunction pentacene/C60 OPVs. The sensor utilizes the considerable fraction of emitted light from conventional thin film OLEDs that is coupled into guided modes in the IRE instead of into the forward (display) direction. A ray-optics description is used to describe light throughput and efficiency-limiting factors for light coupling from the OLED into the substrate modes, light traversing through the IRE substrate, and light coupling into the OPV detectors. The arrangement of the OLED at the center of the chip provides for two sensing regions, a “sample” and “reference” channel, with detection of light by independent OPV detectors. This configuration allows for normalization of the sensor response against fluctuations in OLED light output, stability, and local fluctuations (temperature) which might influence sensor response. The dual beam configuration permits significantly enhanced sensitivity to refractive index changes relative to single-beam protocols, and is easily integrated into a field-portable instrumentation package. Changes in refractive index (ΔR.I.) between 10−2 and 10−3 R.I. units could be detected for single channel operation, with sensitivity increased to ΔR.I. ≈ 10−4 units when the dual beam configuration is employed. PMID:20218580

  9. The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Pla, Conrado; Al-Amro, Abdullah S.; Bahary, Jean-Paul; Villemure, Jean-Guy; Caron, Jean-Louis; Olivier, Andre; Podgorsak, Ervin B.

    1998-01-01

    Purpose: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. Materials and Methods: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. Results: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. Conclusions: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue

  10. Integration of Enzymes in Polyaniline-Sensitized 3D Inverse Opal TiO2 Architectures for Light-Driven Biocatalysis and Light-to-Current Conversion.

    Science.gov (United States)

    Riedel, Marc; Lisdat, Fred

    2018-01-10

    Inspired by natural photosynthesis, coupling of artificial light-sensitive entities with biocatalysts in a biohybrid format can result in advanced photobioelectronic systems. Herein, we report on the integration of sulfonated polyanilines (PMSA1) and PQQ-dependent glucose dehydrogenase (PQQ-GDH) into inverse opal TiO 2 (IO-TiO 2 ) electrodes. While PMSA1 introduces sensitivity for visible light into the biohybrid architecture and ensures the efficient wiring between the IO-TiO 2 electrode and the biocatalytic entity, PQQ-GDH provides the catalytic activity for the glucose oxidation and therefore feeds the light-driven reaction with electrons for an enhanced light-to-current conversion. Here, the IO-TiO 2 electrodes with pores of around 650 nm provide a suitable interface and morphology needed for the stable and functional assembly of polymer and enzyme. The IO-TiO 2 electrodes have been prepared by a template approach applying spin coating, allowing an easy scalability of the electrode height and surface area. The successful integration of the polymer and the enzyme is confirmed by the generation of an anodic photocurrent, showing an enhanced magnitude with increasing glucose concentrations. Compared to flat and nanostructured TiO 2 electrodes, the three-layered IO-TiO 2 electrodes give access to a 24-fold and 29-fold higher glucose-dependent photocurrent due to the higher polymer and enzyme loading in IO films. The three-dimensional IO-TiO 2 |PMSA1|PQQ-GDH architecture reaches maximum photocurrent densities of 44.7 ± 6.5 μA cm -2 at low potentials in the presence of glucose (for a three TiO 2 layer arrangement). The onset potential for the light-driven substrate oxidation is found to be at -0.315 V vs Ag/AgCl (1 M KCl) under illumination with 100 mW cm -2 , which is more negative than the redox potential of the enzyme. The results demonstrate the advantageous properties of IO-TiO 2 |PMSA1|PQQ-GDH biohybrid architectures for the light-driven glucose conversion

  11. Effects of low or high doses of short wavelength ultraviolet light (UVB) on Langerhans cells and skin allograft survival

    International Nuclear Information System (INIS)

    Odling, K.A.; Halliday, G.M.; Muller, H.K.

    1987-01-01

    Donor C57BL mouse shaved dorsal trunk or tail skin was exposed to high (200 mJ/cm 2 ) or low (40 mJ/cm 2 ) doses of short wavelength ultraviolet light (UVB) before grafting on to the thorax of BALB/c mouse recipients of the same sex. Skin grafted 1-14 days following a single high dose of UVB irradiation was ultrastructurally depleted of LC and survived significantly longer than unirradiated skin before being rejected. After a 21-day interval between exposure and grafting when LC were again present in the epidermis there was no significant difference between treated and control graft survival. Exposure to low dose UVB irradiation only significantly increased graft survival for skin transplanted 1-3 days after irradiation; skin grafted 4 days following irradiation survived for a similar period to unirradiated control skin grafts. Electronmicroscopy showed that the low UVB dose did not deplete LC from the epidermis. We conclude that after low dose UVB treatment the class II MHC antigens on the LC Plasma membrane were lost temporarily, thus prolonging graft survival, but when the plasma membrane antigens were re-expressed graft survival returned to normal. In contrast, high-dose UVB irradiation prolonged graft survival by depleting LC from the epidermis, with graft survival only returning to control values as LC repopulated the epidermis

  12. Dose-escalated simultaneous integrated-boost treatment of prostate cancer patients via helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Geier, M.; Astner, S.T.; Duma, M.N.; Putzhammer, J.; Winkler, C.; Molls, M.; Geinitz, H. [Technische Univ. Muenchen (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Jacob, V. [Universitaetsklinikum Freiburg (Germany). Klinik fuer Strahlenheilkunde; Nieder, C. [Nordland Hospital, Bodoe (Norway). Dept. of Oncology and Palliative Care; Tromsoe Univ. (Norway). Inst. of Clinical Medicine

    2012-05-15

    The goal of this work was to assess the feasibility of moderately hypofractionated simultaneous integrated-boost intensity-modulated radiotherapy (SIB-IMRT) with helical tomotherapy in patients with localized prostate cancer regarding acute side effects and dose-volume histogram data (DVH data). Acute side effects and DVH data were evaluated of the first 40 intermediate risk prostate cancer patients treated with a definitive daily image-guided SIB-IMRT protocol via helical tomotherapy in our department. The planning target volume including the prostate and the base of the seminal vesicles with safety margins was treated with 70 Gy in 35 fractions. The boost volume containing the prostate and 3 mm safety margins (5 mm craniocaudal) was treated as SIB to a total dose of 76 Gy (2.17 Gy per fraction). Planning constraints for the anterior rectal wall were set in order not to exceed the dose of 76 Gy prescribed to the boost volume. Acute toxicity was evaluated prospectively using a modified CTCAE (Common Terminology Criteria for Adverse Events) score. SIB-IMRT allowed good rectal sparing, although the full boost dose was permitted to the anterior rectal wall. Median rectum dose was 38 Gy in all patients and the median volumes receiving at least 65 Gy (V65), 70 Gy (V70), and 75 Gy (V75) were 13.5%, 9%, and 3%, respectively. No grade 4 toxicity was observed. Acute grade 3 toxicity was observed in 20% of patients involving nocturia only. Grade 2 acute intestinal and urological side effects occurred in 25% and 57.5%, respectively. No correlation was found between acute toxicity and the DVH data. This institutional SIB-IMRT protocol using daily image guidance as a precondition for smaller safety margins allows dose escalation to the prostate without increasing acute toxicity. (orig.)

  13. Hypericin photocytotoxicyty followed after fractionated light irradiation

    International Nuclear Information System (INIS)

    Sackova, V.; Kulikova, L.; Mikes, J.; Kleban, J.; Fedorocko, P.

    2006-01-01

    The present study demonstrates the in vitro effect of hypericin-mediated photodynamic therapy with fractionated light delivery. Cells were photosensitized with unequal light fractions separated by dark intervals (1 h, 6 h). The changes in survival, apoptosis and cell cycle were compared on HT-29 cells irradiated with a single light dose (12 J/cm 2 ) to the fractionated light delivery (1+11 J/cm 2 ) 24 h and 48 h after photodynamic treatment. It was found that a fractionated light regime with a longer dark period resulted in a decrease of hypericin photo-cytotoxicity. Cell survival was higher after light sensitization with a 6 h dark interval. DNA fragmentation occurred after a single light dose application, but in contrast no apoptotic DNA formation was detected with a 6 h dark pause. After fractionation the percentage of cells in G 1 phase of the cell cycle was increased, while the proportion of cells in the G 2 phase decreased as compared to a single light dose application i. e. both percentage of cells in G 1 and G 2 phase of cell cycle were near control levels. We presume that the longer dark interval after the irradiation of cells by first light dose makes them to resistant to the effect of the second illumination. These findings confirm that the light application scheme together with other photodynamic protocol components is crucial for the photo-cytotoxicity of hypericin. (authors)

  14. Selective epitaxial growth of monolithically integrated GaN-based light emitting diodes with AlGaN/GaN driving transistors

    International Nuclear Information System (INIS)

    Liu, Zhaojun; Ma, Jun; Huang, Tongde; Liu, Chao; May Lau, Kei

    2014-01-01

    In this Letter, we report selective epitaxial growth of monolithically integrated GaN-based light emitting diodes (LEDs) with AlGaN/GaN high-electron-mobility transistor (HEMT) drivers. A comparison of two integration schemes, selective epitaxial removal (SER), and selective epitaxial growth (SEG) was made. We found the SER resulted in serious degradation of the underlying LEDs in a HEMT-on-LED structure due to damage of the p-GaN surface. The problem was circumvented using the SEG that avoided plasma etching and minimized device degradation. The integrated HEMT-LEDs by SEG exhibited comparable characteristics as unintegrated devices and emitted modulated blue light by gate biasing

  15. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  16. Radioactivity in food and the environment: calculations of UK radiation doses using integrated methods

    International Nuclear Information System (INIS)

    Allott, Rob

    2003-01-01

    Dear Sir: I read with interest the paper by W C Camplin, G P Brownless, G D Round, K Winpenny and G J Hunt from the Centre for Environment, Fisheries and Aquaculture Science (CEFAS) on 'Radioactivity in food and the environment: calculations of UK radiation doses using integrated methods' in the December 2002 issue of this journal (J. Radiol. Prot. 22 371-88). The Environment Agency has a keen interest in the development of a robust methodology for assessing total doses which have been received by members of the public from authorised discharges of radioactive substances to the environment. Total dose in this context means the dose received from all authorised discharges and all exposure pathways (e.g. inhalation, external irradiation from radionuclides in sediment/soil, direct radiation from operations on a nuclear site, consumption of food etc). I chair a 'total retrospective dose assessment' working group with representatives from the Scottish Environment Protection Agency (SEPA), Food Standards Agency (FSA), National Radiological Protection Board, CEFAS and BNFL which began discussing precisely this issue during 2002. This group is a sub-group of the National Dose Assessment Working Group which was set up in April 2002 (J. Radiol. Prot. 22 318-9). The Environment Agency, Food Standards Agency and the Nuclear Installations Inspectorate previously undertook joint research into the most appropriate methodology to use for total dose assessment (J J Hancox, S J Stansby and M C Thorne 2002 The Development of a Methodology to Assess Population Doses from Multiple Source and Exposure Pathways of Radioactivity (Environment Agency R and D Technical Report P3-070/TR). This work came to broadly the same conclusion as the work by CEFAS, that an individual dose method is probably the most appropriate method to use. This research and that undertaken by CEFAS will help the total retrospective dose assessment working group refine a set of principles and a methodology for the

  17. Sensory integration of a light touch reference in human standing balance

    Science.gov (United States)

    Smith, Craig P.; Reynolds, Raymond F.

    2018-01-01

    In upright stance, light touch of a space-stationary touch reference reduces spontaneous sway. Moving the reference evokes sway responses which exhibit non-linear behavior that has been attributed to sensory reweighting. Reweighting refers to a change in the relative contribution of sensory cues signaling body sway in space and light touch cues signaling finger position with respect to the body. Here we test the hypothesis that the sensory fusion process involves a transformation of light touch signals into the same reference frame as other sensory inputs encoding body sway in space, or vice versa. Eight subjects lightly gripped a robotic manipulandum which moved in a circular arc around the ankle joint. A pseudo-randomized motion sequence with broad spectral characteristics was applied at three amplitudes. The stimulus was presented at two different heights and therefore different radial distances, which were matched in terms of angular motion. However, the higher stimulus evoked a significantly larger sway response, indicating that the response was not matched to stimulus angular motion. Instead, the body sway response was strongly related to the horizontal translation of the manipulandum. The results suggest that light touch is integrated as the horizontal distance between body COM and the finger. The data were well explained by a model with one feedback loop minimizing changes in horizontal COM-finger distance. The model further includes a second feedback loop estimating the horizontal finger motion and correcting the first loop when the touch reference is moving. The second loop includes the predicted transformation of sensory signals into the same reference frame and a non-linear threshold element that reproduces the non-linear sway responses, thus providing a mechanism that can explain reweighting. PMID:29874252

  18. Laser cooling of neutral atoms by red-shifted diffuse light in an optical integral sphere cavity

    International Nuclear Information System (INIS)

    Wang Yuzhu; Chen Hongxin; Cai Weiquan; Liu Liang; Zhou Shanyu; Shu Wei; Li Fosheng

    1994-01-01

    In this paper, we report a cooling and deceleration experiment of a thermal beam by using a nearly resonant red-shifted diffuse light in an optical integral sphere cavity. With this red-shifted diffuse light, a part of thermal sodium atoms is cooled to 380m/s and the velocity width of cooled atoms is about 20m/s. The mechanism of this kind of laser cooling and the experimental results are discussed. (author). 12 refs, 5 figs

  19. Occupational radiation dose statistics from light-water power reactors operating in Western Europe

    International Nuclear Information System (INIS)

    Brookes, I.R.; Eng, T.

    1987-01-01

    Since the early days of nuclear power, collective and individual doses for people engaged in the maintenance and operation of nuclear power plants have been published by regulatory authorities. In 1979 a small working party whose members were drawn from Member States operating light-water reactors (LWRs) in the European Community was convened. The working party decided that only by collection of data under a unified scheme would it ever be possible to properly compare plant performance and for this reason a questionnaire was drawn up which attempted to elicit the maximum of information with the minimum inconvenience to the plant staff. Another decision made by the working party was to broaden the data base from 'European Community LWRs' to 'West European LWRs' to try to take advantage of the considerable experience being built up in Sweden, in Finland and in Switzerland. All the data available to the Commission up to the end of 1984 are presented and commented on. The deductions are not exhaustive but are believed to represent the limits of what could sensibly be done with the data available. Results are presented separately for BWR and PWR but no other subdivision, say by country or maker, is made. Where interpretation can be enhanced by graphical presentation, this is done. In general, doses for each job category are expressed in various ways to reveal and afford comparisons

  20. The reciprocity law concerning light dose relationships applied to BisGMA/TEGDMA photopolymers: theoretical analysis and experimental characterization.

    Science.gov (United States)

    Wydra, James W; Cramer, Neil B; Stansbury, Jeffrey W; Bowman, Christopher N

    2014-06-01

    A model BisGMA/TEGDMA unfilled resin was utilized to investigate the effect of varied irradiation intensity on the photopolymerization kinetics and shrinkage stress evolution, as a means for evaluation of the reciprocity relationship. Functional group conversion was determined by FTIR spectroscopy and polymerization shrinkage stress was obtained by a tensometer. Samples were polymerized with UV light from an EXFO Acticure with 0.1wt% photoinitiator. A one-dimensional kinetic model was utilized to predict the conversion-dose relationship. As irradiation intensity increased, conversion decreased at a constant irradiation dose and the overall dose required to achieve full conversion increased. Methacrylate conversion ranged from 64±2% at 3mW/cm(2) to 78±1% at 24mW/cm(2) while the final shrinkage stress varied from 2.4±0.1MPa to 3.0±0.1MPa. The ultimate conversion and shrinkage stress levels achieved were dependent not only upon dose but also the irradiation intensity, in contrast to an idealized reciprocity relationship. A kinetic model was utilized to analyze this behavior and provide theoretical conversion profiles versus irradiation time and dose. Analysis of the experimental and modeling results demonstrated that the polymerization kinetics do not and should not be expected to follow the reciprocity law behavior. As irradiation intensity is increased, the overall dose required to achieve full conversion also increased. Further, the ultimate conversion and shrinkage stress that are achieved are not dependent only upon dose but rather upon the irradiation intensity and corresponding polymerization rate. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams.

    Science.gov (United States)

    Masood, U; Cowan, T E; Enghardt, W; Hofmann, K M; Karsch, L; Kroll, F; Schramm, U; Wilkens, J J; Pawelke, J

    2017-07-07

    Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam

  2. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams

    Science.gov (United States)

    Masood, U.; Cowan, T. E.; Enghardt, W.; Hofmann, K. M.; Karsch, L.; Kroll, F.; Schramm, U.; Wilkens, J. J.; Pawelke, J.

    2017-07-01

    Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam

  3. Radiation apparatus with distance mapper for dose control

    International Nuclear Information System (INIS)

    Saunders, A.M.

    1990-01-01

    The patent describes apparatus for delivering a radiation dose. It comprises: radiation source means for producing a beam of ionizing gamma ray or x-ray radiation directed so as to deliver a dose of the radiation to an area of a target surface, a light source emitting a light beam in a direction transverse to the direction of the ionizing radiation beam, a photodetector, positioned to receive light scattered from the target surface, means for scanning the light beam over the area of the target surface, means for forming a three-dimensional surface profile map of the area of the target surface without movement of the radiation source means or the light source, and means responsive to the surface profile map for adjusting the dose of radiation from the radiation source over the area of the target surface, so that the radiation source means and the light source may be operated simultaneously

  4. No indications of an enhanced UV-light-induced unscheduled DNA synthesis in splenocytes of mice following a low-dose irradiation in vivo or in vitro

    International Nuclear Information System (INIS)

    Wojcik, A.; Seemayer, C.A.; Mueller, W.U.; Streffer, C.

    1995-01-01

    One of the open questions regarding the adaptive response to ionizing radiation is whether it can be induced in G 0 lymphocytes. In the majority of experiments in which an adaptive response in G 0 lymphocytes was observed, the adapting dose was applied in vivo. In order to investigate whether there is some in vivo component of adaptive response, mouse splenocytes of the C57BL/6 strain were irradiated with 0.1 Gy x-rays either in vivo or in vitro, and their UV-light-induced unscheduled DNA synthesis (UDS) levels were determined autoradiographically. An augmented UV-light-induced UDS following an adapting dose applied in vivo has previously been described by several authors in splenocytes of C57BL/6 mice, indicating that the adapting dose enhanced the DNA repair capacity of lymphocytes. In the present investigation, however, no evidence of an adaptive response could be seen regardless of whether the adapting dose was given in vivo or in vitro. Those results present a further indication for the fact that the adaptive response to ionizing radiation is not always inducible, even in lymphocytes of an inbred mouse strain in which its existence has been reported before. (orig.)

  5. Integral Inherently Safe Light Water Reactor (I2S-LWR)

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, Bojan [Georgia Inst. of Technology, Atlanta, GA (United States); Memmott, Matthew [Brigham Young Univ., Provo, UT (United States); Boy, Guy [Florida Inst. of Technology, Melbourne, FL (United States); Charit, Indrajit [Univ. of Idaho, Moscow, ID (United States); Manera, Annalisa [Univ. of Michigan, Ann Arbor, MI (United States); Downar, Thomas [Univ. of Michigan, Ann Arbor, MI (United States); Lee, John [Univ. of Michigan, Ann Arbor, MI (United States); Muldrow, Lycurgus [Morehouse College, Atlanta, GA (United States); Upadhyaya, Belle [Univ. of Tennessee, Knoxville, TN (United States); Hines, Wesley [Univ. of Tennessee, Knoxville, TN (United States); Haghighat, Alierza [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2017-10-02

    This final report summarizes results of the multi-year effort performed during the period 2/2013- 12/2016 under the DOE NEUP IRP Project “Integral Inherently Safe Light Water Reactors (I2S-LWR)”. The goal of the project was to develop a concept of a 1 GWe PWR with integral configuration and inherent safety features, at the same time accounting for lessons learned from the Fukushima accident, and keeping in mind the economic viability of the new concept. Essentially (see Figure 1-1) the project aimed to implement attractive safety features, typically found only in SMRs, to a larger power (1 GWe) reactor, to address the preference of some utilities in the US power market for unit power level on the order of 1 GWe.

  6. Integrated Wavelength-Tunable Light Source for Optical Gas Sensing Systems

    Directory of Open Access Journals (Sweden)

    Bin Li

    2015-01-01

    Full Text Available A compact instrument consisting of a distributed feedback laser (DFB at 1.65 μm was developed as a light source for gas sensing systems using tunable diode laser absorption spectroscopy (TDLAS technique. The wavelength of laser is tuned by adjusting the laser working temperature and injection current, which are performed by self-developed temperature controller and current modulator respectively. Stability test shows the fluctuation of the laser temperature is within the range of ±0.02°C. For gas detection experiments, the wavelength is tuned around the gas absorption line by adjusting laser temperature and is then shifted periodically to scan across the absorption line by the laser current modulator, which generates a 10 Hz saw wave signal. In addition, the current modulator is able to generate sine wave signal for gas sensing systems using wavelength modulation spectroscopy (WMS technique involving extraction of harmonic signals. The spectrum test proves good stability that the spectrum was measured 6 times every 10 minutes at the constant temperature and current condition. This standalone instrument can be applied as a light source for detection systems of different gases by integrating lasers at corresponding wavelength.

  7. Integrated Design Optimization of a 5-DOF Assistive Light-weight Anthropomorphic Arm

    DEFF Research Database (Denmark)

    Zhou, Lelai; Bai, Shaoping; Hansen, Michael Rygaard

    2011-01-01

    An integrated dimensional and drive train optimization method was developed for light-weight robotic arm design. The method deals with the determination of optimal link lengths and the optimal selection of motors and gearboxes from commercially available components. Constraints are formulated...... on the basis of kinematic performance and dynamic requirements, whereas the main objective is to minimize the weight. The design of a human-like arm, which is 10 kg in weight with a load capacity of 5 kg, is described....

  8. TCM in lighting design : an integrative medical methodology in light research

    NARCIS (Netherlands)

    Pan, Y.; Zielinska-Dabkowska, Karolina M.; Rohde, Michael F.

    2017-01-01

    The advancement of artificial lighting technology has enabled a lifestyle free from the restriction of natural daylight. However, scientists have discovered that light, assisting the cardiovascular system and synchronizing the biological clock, is a vital form of energy and information to sustain

  9. Integrated control of sun shades, daylight and artificial light; Integreret regulering af solafskaermning, dagslys og kunstlys

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, K.; Christoffersen, J.; Soerensen, Henrik; Jessen, G.

    2011-07-01

    The project established a basis of calculation and a practical basis for optimum choice of solar shading and integrated control strategies for both new buildings and for office, commercial and institutional buildings to be renovated with new calculation models for controlling solar shading integrated in the BSim program. A complete and applicable model for optimum, integrated solar shading control was established, focusing on thermal and visual comfort criteria towards energy consumption for heating, cooling and lighting. A prototype was tested in the daylight laboratory at Danish Building Research Institute-Aalborg University and at University of Southern Denmark. (LN)

  10. Simulating propagation of coherent light in random media using the Fredholm type integral equation

    Science.gov (United States)

    Kraszewski, Maciej; Pluciński, Jerzy

    2017-06-01

    Studying propagation of light in random scattering materials is important for both basic and applied research. Such studies often require usage of numerical method for simulating behavior of light beams in random media. However, if such simulations require consideration of coherence properties of light, they may become a complex numerical problems. There are well established methods for simulating multiple scattering of light (e.g. Radiative Transfer Theory and Monte Carlo methods) but they do not treat coherence properties of light directly. Some variations of these methods allows to predict behavior of coherent light but only for an averaged realization of the scattering medium. This limits their application in studying many physical phenomena connected to a specific distribution of scattering particles (e.g. laser speckle). In general, numerical simulation of coherent light propagation in a specific realization of random medium is a time- and memory-consuming problem. The goal of the presented research was to develop new efficient method for solving this problem. The method, presented in our earlier works, is based on solving the Fredholm type integral equation, which describes multiple light scattering process. This equation can be discretized and solved numerically using various algorithms e.g. by direct solving the corresponding linear equations system, as well as by using iterative or Monte Carlo solvers. Here we present recent development of this method including its comparison with well-known analytical results and a finite-difference type simulations. We also present extension of the method for problems of multiple scattering of a polarized light on large spherical particles that joins presented mathematical formalism with Mie theory.

  11. Independent dose calculation in IMRT for the Tps Iplan using the Clarkson modified integral; Calculo independiente de dosis en IMRT para el TPS Iplan usando la integral modificada de Clarkson

    Energy Technology Data Exchange (ETDEWEB)

    Adrada, A.; Tello, Z.; Garrigo, E.; Venencia, D., E-mail: jorge.alberto.adrada@gmail.com [Instituto Privado de Radioterapia, Obispo Oro 423, X5000BFI Cordoba (Argentina)

    2014-08-15

    Intensity-Modulated Radiation Therapy (IMRT) treatments require a quality assurance (Q A) specific patient before delivery. These controls include the experimental verification in dose phantom of the total plan as well as dose distributions. The use of independent dose calculation (IDC) is used in 3D-Crt treatments; however its application in IMRT requires the implementation of an algorithm that allows considering a non-uniform intensity beam. The purpose of this work was to develop IDC software in IMRT with MLC using the algorithm proposed by Kung (Kung et al. 2000). The software was done using Matlab programming. The Clarkson modified integral was implemented on each flowing, applying concentric rings for the dose determination. From the integral of each field was calculated the dose anywhere. One time finished a planning; all data are exported to a phantom where a Q A plan is generated. On this is calculated the half dose in a representative volume of the ionization chamber and the dose at the center of it. Until now 230 IMRT planning were analyzed carried out ??in the treatment planning system (Tps) Iplan. For each one of them Q A plan was generated, were calculated and compared calculated dose with the Tps, IDC system and measurement with ionization chamber. The average difference between measured and calculated dose with the IDC system was 0.4% ± 2.2% [-6.8%, 6.4%]. The difference between the measured and the calculated doses by the pencil-beam algorithm (Pb) of Tps was 2.6% ± 1.41% [-2.0%, 5.6%] and with the Monte Carlo algorithm was 0.4% ± 1.5% [-4.9%, 3.7%]. The differences of the carried out software are comparable to the obtained with the ionization chamber and Tps in Monte Carlo mode. (author)

  12. Integration of Organic Light Emitting Diodes and Organic Photodetectors for Lab-on-a-Chip Bio-Detection Systems

    Directory of Open Access Journals (Sweden)

    Graeme Williams

    2014-02-01

    Full Text Available The rapid development of microfluidics and lab-on-a-chip (LoC technologies have allowed for the efficient separation and manipulation of various biomaterials, including many diagnostically relevant species. Organic electronics have similarly enjoyed a great deal of research, resulting in tiny, highly efficient, wavelength-selective organic light-emitting diodes (OLEDs and organic photodetectors (OPDs. We consider the blend of these technologies for rapid detection and diagnosis of biological species. In the ideal system, optically active or fluorescently labelled biological species can be probed via light emission from OLEDs, and their subsequent light emission can be detected with OPDs. The relatively low cost and simple fabrication of the organic electronic devices suggests the possibility of disposable test arrays. Further, with full integration, the finalized system can be miniaturized and made simple to use. In this review, we consider the design constraints of OLEDs and OPDs required to achieve fully organic electronic optical bio-detection systems. Current approaches to integrated LoC optical sensing are first discussed. Fully realized OLED- and OPD-specific photoluminescence detection systems from literature are then examined, with a specific focus on their ultimate limits of detection. The review highlights the enormous potential in OLEDs and OPDs for integrated optical sensing, and notes the key avenues of research for cheap and powerful LoC bio-detection systems.

  13. Utilization of radiation protection gear for absorbed dose reduction: an integrative literature review

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Flor, Rita de Cassia; Pereira, Aline Garcia

    2011-01-01

    Objective: The present study was aimed at evaluating the relation between the use of radiation protection gear and the decrease in absorbed dose of ionizing radiation, thereby reinforcing the efficacy of its use by both the patients and occupationally exposed personnel. Materials and Methods: The integrative literature review method was utilized to analyze 21 articles, 2 books, 1 thesis, 1 monograph, 1 computer program, 4 pieces of database research (Instituto Brasileiro de Geografia e Estatistica and Departamento de Informatica do Sistema Unico de Saude) and 2 sets of radiological protection guidelines. Results: Theoretically, a reduction of 86% to 99% in the absorbed dose is observed with the use of radiation protection gear. In practice, however, the reduction may achieve 88% in patients submitted to conventional radiology, and 95% in patients submitted to computed tomography. In occupationally exposed individuals, the reduction is around 90% during cardiac catheterization, and 75% during orthopedic surgery. Conclusion: According to findings of several previous pieces of research, the use of radiation protection gear is a low-cost and effective way to reduce absorbed dose both for patients and occupationally exposed individuals. Thus, its use is necessary for the implementation of effective radioprotection programs in radiodiagnosis centers. (author)

  14. Can light make us bright? Effects of light on cognition and sleep

    NARCIS (Netherlands)

    Chellappa, Sarah Laxhmi; Gordijn, Marijke C. M.; Cajochen, Christian; VanDongen, HPA; Kerkhof, GA

    2011-01-01

    Light elicits robust nonvisual effects on numerous physiological and behavioral variables, such as the human sleep-wake cycle and cognitive performance. Light effects crucially rely on properties such as dose, duration, timing, and wavelength. Recently, the use of methods such as fMRI to assess

  15. Modification of photo-thermal model by accommodating light integrals using antirrhinum flowering and leaf number data from restricted range of environmental conditions

    International Nuclear Information System (INIS)

    Hadley, P.; Carew, J.; Pearson, S.

    2017-01-01

    The objective of study was to quantify the flowering and leaf number response of Antirrhinum majus L. cv. Chimes White to different photoperiods, night temperatures and light integrals using photo-thermal model. Two experiments were conducted i.e. first one in February (under low ambient light integrals) and the second one in June (under high ambient light integrals). In each experiment plants of an early flowering cv. Chimes White were transferred (after 80% germination) to two night temperature suits (set-point temperatures 10 and 20 degree C), each having four photoperiod chambers (8, 11, 14 and 17 h.d-1). Results revealed that plants flowered earlier at long photoperiod (17 h.d-1), higher mean diurnal temperature (19.2 degree C in February and 23.4 degree C in June) and high ambient light integrals (8.26 MJ.m-2.d-1) and vice versa. These findings were successfully incorporated in to photo-thermal model, which was not reported before in Antirrhinum. The simple linear model hence updated, which would be helpful for growers to predict and quantify flowering time and leaf number (plant quality) of Antirrhinum well before their plantation to maintain its continual supply to the market. (author)

  16. Simulating and evaluating an adaptive and integrated traffic lights control system for smart city application

    Science.gov (United States)

    Djuana, E.; Rahardjo, K.; Gozali, F.; Tan, S.; Rambung, R.; Adrian, D.

    2018-01-01

    A city could be categorized as a smart city when the information technology has been developed to the point that the administration could sense, understand, and control every resource to serve its people and sustain the development of the city. One of the smart city aspects is transportation and traffic management. This paper presents a research project to design an adaptive traffic lights control system as a part of the smart system for optimizing road utilization and reducing congestion. Research problems presented include: (1) Congestion in one direction toward an intersection due to dynamic traffic condition from time to time during the day, while the timing cycles in traffic lights system are mostly static; (2) No timing synchronization among traffic lights in adjacent intersections that is causing unsteady flows; (3) Difficulties in traffic condition monitoring on the intersection and the lack of facility for remotely controlling traffic lights. In this research, a simulator has been built to model the adaptivity and integration among different traffic lights controllers in adjacent intersections, and a case study consisting of three sets of intersections along Jalan K. H. Hasyim Ashari has been simulated. It can be concluded that timing slots synchronization among traffic lights is crucial for maintaining a steady traffic flow.

  17. Mobile-Dose: A Dose-Meter Designed for Use in Automatic Machineries for Dose Manipulation in Nuclear Medicine

    Science.gov (United States)

    de Asmundis, Riccardo; Boiano, Alfonso; Ramaglia, Antonio

    2008-06-01

    Mobile-Dose has been designed for a very innovative use: the integration in a robotic machinery for automatic preparation of radioactive doses, to be injected to patients in Nuclear Medicine Departments, with real time measurement of the activity under preparation. Mobile-Dose gives a constant measurement of the dose during the filling of vials or syringes, triggering the end of the filling process based on a predefined dose limit. Several applications of Mobile-Dose have been delivered worldwide, from Italian hospitals and clinics to European and Japanese ones. The design of such an instrument and its integration in robotic machineries, was required by an Italian company specialised in radiation protection tools for nuclear applications, in the period 2001-2003. At the time of its design, apparently no commercial instruments with a suitable interfacing capability to the external world existed: we designed it in order to satisfy all the strict requirements coming from the medical aspects (precision within 10%, repeatability, stability, time response) and from the industrial conceiving principles that are mandatory to ensure a good reliability in such a complicated environment. The instrument is suitable to be used in standalone mode too, thanks to its portability and compactness and to the intelligent operator panel programmed for this purpose.

  18. A Dosimetric Comparison of Dose Escalation with Simultaneous Integrated Boost for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Wenjuan Yang

    2017-01-01

    Full Text Available Background. Many studies have demonstrated that a higher radiotherapy dose is associated with improved outcomes in non-small-cell lung cancer (NSCLC. We performed a dosimetric planning study to assess the dosimetric feasibility of intensity-modulated radiation therapy (IMRT with a simultaneous integrated boost (SIB in locally advanced NSCLC. Methods. We enrolled twenty patients. Five different dose plans were generated for each patient. All plans were prescribed a dose of 60 Gy to the planning tumor volume (PTV. In the three SIB groups, the prescribed dose was 69 Gy, 75 Gy, and 81 Gy in 30 fractions to the internal gross tumor volume (iGTV. Results. The SIB-IMRT plans were associated with a significant increase in the iGTV dose (P < 0.05, without increased normal tissue exposure or prolonged overall treatment time. Significant differences were not observed in the dose to the normal lung in terms of the V5 and V20 among the four IMRT plans. The maximum dose (Dmax in the esophagus moderately increased along with the prescribed dose (P < 0.05. Conclusions. Our results indicated that escalating the dose by SIB-IMRT is dosimetrically feasible; however, systematic evaluations via clinical trials are still warranted. We have designed a further clinical study (which is registered with ClinicalTrials.gov, number NCT02841228.

  19. Traffic Light Detection

    DEFF Research Database (Denmark)

    Philipsen, Mark Philip; Jensen, Morten Bornø; Møgelmose, Andreas

    2015-01-01

    Traffic light recognition (TLR) is an integral part of any intelligent vehicle, which must function in the existing infrastructure. Pedestrian and sign detection have recently seen great improvements due to the introduction of learning based detectors using integral channel features. A similar push...... database is collected based on footage from US roads. The database consists of both test and training data, totaling 46,418 frames and 112,971 annotated traffic lights, captured in continuous sequences under a varying light and weather conditions. The learning based detector achieves an AUC of 0.4 and 0...

  20. Functions and requirements for the Light-Duty Utility Arm Integrated System. Revision 1

    International Nuclear Information System (INIS)

    Kiebel, G.R.

    1996-01-01

    The Light Duty Utility Arm (LDUA) Integrated System is a mobile robotic system designed to remotely deploy and operate a variety of tools in uninhabitable underground radiological and hazardous waste storage tanks. The system primarily provides a means to inspect, survey, monitor, map and/or obtain specific waste and waste tank data in support of the Tank Waste Remediation System (TWRS) mission at Hanford and remediation programs at other U.S. Department of Energy (DOE) sites

  1. Image gently, step lightly: increasing radiation dose awareness in pediatric interventions through an international social marketing campaign.

    Science.gov (United States)

    Sidhu, Manrita K; Goske, Marilyn J; Coley, Brian J; Connolly, Bairbre; Racadio, John; Yoshizumi, Terry T; Utley, Tara; Strauss, Keith J

    2009-09-01

    In the past several decades, advances in imaging and interventional techniques have been accompanied by an increase in medical radiation dose to the public. Radiation exposure is even more important in children, who are more sensitive to radiation and have a longer lifespan during which effects may manifest. To address radiation safety in pediatric computed tomography, in 2008 the Alliance for Radiation Safety in Pediatric Imaging launched an international social marketing campaign entitled Image Gently. This article describes the next phase of the Image Gently campaign, entitled Step Lightly, which focuses on radiation safety in pediatric interventional radiology.

  2. Lighting Design

    DEFF Research Database (Denmark)

    Hansen, Ellen Kathrine; Mullins, Michael

    2014-01-01

    of design developed from three experiments show how distinct qualitative and quantitative criteria in different disciplinary traditions can be integrated successfully, despite disparate technical/scientific, social scientific and art/humanities backgrounds. The model is applied to a pedagogical curriculum......Light as a multi-dimensional design element has fundamental importance for a sustainable environment. The paper discusses the need for an integration of scientific, technical and creative approaches to light and presents theory, methods and applications toward fulfilling this need. A theory...

  3. Dose rate effects during damage accumulation in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Caturla, M.J.; Diaz de la Rubia, T.

    1997-01-01

    We combine molecular dynamics and Monte Carlo simulations to study damage accumulation and dose rate effects during irradiation of Silicon. We obtain the initial stage of the damage produced by heavy and light ions using classical molecular dynamics simulations. While heavy ions like As or Pt induce amorphization by single ion impact, light ions like B only produce point defects or small clusters of defects. The amorphous pockets generated by heavy ions are stable below room temperature and recrystallize at temperatures below the threshold for recrystallization of a planar amorphous-crystalline interface. The damage accumulation during light ion irradiation is simulated using a Monte Carlo model for defect diffusion. In this approach, we study the damage in the lattice as a function of dose and dose rate. A strong reduction in the total number of defects left in the lattice is observed for lower dose rates.

  4. Dose rate effects during damage accumulation in silicon

    International Nuclear Information System (INIS)

    Caturla, M.J.; Diaz de la Rubia, T.

    1997-01-01

    The authors combine molecular dynamics and Monte Carlo simulations to study damage accumulation and dose rate effects during irradiation of silicon. They obtain the initial stage of the damage produced by heavy and light ions using classical molecular dynamics simulations. While heavy ions like As or Pt induce amorphization by single ion impact, light ions like B only produce point defects or small clusters of defects. The amorphous pockets generated by heavy ions are stable below room temperature and recrystallize at temperatures below the threshold for recrystallization of a planar amorphous-crystalline interface. The damage accumulation during light ion irradiation is simulated using a Monte Carlo model for defect diffusion. In this approach, the authors study the damage in the lattice as a function of dose and dose rate. A strong reduction in the total number of defects left in the lattice is observed for lower dose rates

  5. Preliminary risk assessment of the Integral Inherently-Safe Light Water Reactor

    International Nuclear Information System (INIS)

    McCarroll, Kellen R.; Lee, John C.; Manera, Annalisa; Memmott, Matthew J.; Ferroni, Paolo

    2017-01-01

    The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) concept seeks to significantly increase nuclear power plant safety. The project implements a safety-by-design philosophy, eliminating several initiating events and providing novel, passive safety systems at the conceptual phase. Pursuit of unparalleled safety employs an integrated development process linking design with deterministic and probabilistic safety analyses. Unique aspects of the I 2 S-LWR concept and design process present challenges to the probabilistic risk assessment (PRA), particularly regarding overall flexibility, auditability and resolution of results. Useful approaches to initiating events and conditional failures are presented. To exemplify the risk-informed design process using PRA, a trade-off study of two safety system configurations is presented. Although further optimization is required, preliminary results indicate that the I 2 S-LWR can achieve a core damage frequency (CDF) from internal events less than 1.01 × 10 −8 /ry, including reactor vessel ruptures. Containment bypass frequency due to primary heat exchanger rupture is found to be comparable to non-vessel rupture CDF.

  6. Correlative and integrated light and electron microscopy of in-resin GFP fluorescence, used to localise diacylglycerol in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Peddie, Christopher J.; Blight, Ken; Wilson, Emma [Electron Microscopy Unit, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Melia, Charlotte [Electron Microscopy Unit, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Cell Biophysics Laboratory, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Department of Molecular Cell Biology, Leiden University Medical Centre, 2300 RC Leiden (Netherlands); Marrison, Jo [Department of Biology, The University of York, Heslington, York (United Kingdom); Carzaniga, Raffaella [Electron Microscopy Unit, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Domart, Marie-Charlotte [Electron Microscopy Unit, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Cell Biophysics Laboratory, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); O' Toole, Peter [Department of Biology, The University of York, Heslington, York (United Kingdom); Larijani, Banafshe [Cell Biophysics Laboratory, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom); Cell Biophysics Laboratory, Unidad de Biofísica (CSIC-UPV/EHU),Sarriena s/n, 48940 Leioa (Spain); IKERBASQUE, Basque Foundation for Science, Bilbao (Spain); Collinson, Lucy M. [Electron Microscopy Unit, London Research Institute, Cancer Research UK, London WC2A 3LY (United Kingdom)

    2014-08-01

    Fluorescence microscopy of GFP-tagged proteins is a fundamental tool in cell biology, but without seeing the structure of the surrounding cellular space, functional information can be lost. Here we present a protocol that preserves GFP and mCherry fluorescence in mammalian cells embedded in resin with electron contrast to reveal cellular ultrastructure. Ultrathin in-resin fluorescence (IRF) sections were imaged simultaneously for fluorescence and electron signals in an integrated light and scanning electron microscope. We show, for the first time, that GFP is stable and active in resin sections in vacuo. We applied our protocol to study the subcellular localisation of diacylglycerol (DAG), a modulator of membrane morphology and membrane dynamics in nuclear envelope assembly. We show that DAG is localised to the nuclear envelope, nucleoplasmic reticulum and curved tips of the Golgi apparatus. With these developments, we demonstrate that integrated imaging is maturing into a powerful tool for accurate molecular localisation to structure. - Highlights: • GFP and mCherry fluorescence are preserved in heavy-metal stained mammalian cells embedded in resin • Fluorophores are stable and intensity is sufficient for detection in ultrathin sections • Overlay of separate LM and EM images from the same ultrathin section improves CLEM protein localisation precision • GFP is stable and active in the vacuum of an integrated light and scanning EM • Integrated light and electron microscopy shows new subcellular locations of the lipid diacylglycerol.

  7. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  8. Urban lighting, light pollution and society

    CERN Document Server

    Meier, Josiane; Krause, Katharina; Pottharst, Merle

    2014-01-01

    After decades "in the shadows", urban lighting is re-emerging as a matter of public debate. Long-standing truths are increasingly questioned as a confluence of developments affects lighting itself and the way it is viewed. Light has become an integral element of place-making and energy-saving initiatives alike. Rapidly evolving lighting technologies are opening up new possibilities, but also posing new challenges to planners, and awareness is growing that artificial illumination is not purely benign but can actually constitute a form of pollution. As a result, public policy frameworks, incentives and initiatives are undergoing a phase of innovation and change that will affect how cities are lit for years to come. The first comprehensive compilation of current scientific discussions on urban lighting and light pollution from a social science and humanities perspective, Urban Lighting, Light Pollution and Society contributes to an evolving international debate on an increasingly controversial topic. The contrib...

  9. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  10. Integrating Gigabit ethernet cameras into EPICS at Diamond light source

    International Nuclear Information System (INIS)

    Cobb, T.

    2012-01-01

    At Diamond Light Source a range of cameras are used to provide images for diagnostic purposes in both the accelerator and photo beamlines. The accelerator and existing beamlines use Point Grey Flea and Flea2 Firewire cameras. We have selected Gigabit Ethernet cameras supporting GigE Vision for our new photon beamlines. GigE Vision is an interface standard for high speed Ethernet cameras which encourages inter-operability between manufacturers. This paper describes the challenges encountered while integrating GigE Vision cameras from a range of vendors into EPICS. GigE Vision cameras appear to be more reliable than the Firewire cameras, and the simple cabling makes much easier to move the cameras to different positions. Upcoming power over Ethernet versions of the cameras will reduce the number of cables still further

  11. WOW: light print, light propel, light point

    Science.gov (United States)

    Glückstad, Jesper; Bañas, Andrew; Aabo, Thomas; Palima, Darwin

    2012-10-01

    We are presenting so-called Wave-guided Optical Waveguides (WOWs) fabricated by two-photon polymerization and capable of being optically manipulated into any arbitrary orientation. By integrating optical waveguides into the structures we have created freestanding waveguides which can be positioned anywhere in a sample at any orientation using real-time 3D optical micromanipulation with six degrees of freedom. One of the key aspects of our demonstrated WOWs is the change in direction of in-coupled light and the marked increase in numerical aperture of the out-coupled light. Hence, each light propelled WOW can tap from a relatively broad incident beam and generate a much more tightly confined light at its tip. The presentation contains both numerical simulations related to the propagation of light through a WOW and preliminary experimental demonstrations on our BioPhotonics Workstation. In a broader context, this research shows that optically trapped micro-fabricated structures can potentially help bridge the diffraction barrier. This structure-mediated paradigm may be carried forward to open new possibilities for exploiting beams from far-field optics down to the sub-wavelength domain.

  12. Visible Lasers and Emerging Color Converters for Lighting and Visible Light Communications

    KAUST Repository

    Shen, Chao

    2017-10-30

    GaN-based lasers are promising for white lighting and visible-light communication (VLC). The advances of III-nitride photonic integration, and the application of YAG crystal and perovskite-based phosphors to lighting and VLC will be discussed.

  13. Visible Lasers and Emerging Color Converters for Lighting and Visible Light Communications

    KAUST Repository

    Shen, Chao

    2017-01-01

    GaN-based lasers are promising for white lighting and visible-light communication (VLC). The advances of III-nitride photonic integration, and the application of YAG crystal and perovskite-based phosphors to lighting and VLC will be discussed.

  14. The first neural probe integrated with light source (blue laser diode) for optical stimulation and electrical recording.

    Science.gov (United States)

    Park, HyungDal; Shin, Hyun-Joon; Cho, Il-Joo; Yoon, Eui-sung; Suh, Jun-Kyo Francis; Im, Maesoon; Yoon, Euisik; Kim, Yong-Jun; Kim, Jinseok

    2011-01-01

    In this paper, we report a neural probe which can selectively stimulate target neurons optically through Si wet etched mirror surface and record extracellular neural signals in iridium oxide tetrodes. Consequently, the proposed approach provides to improve directional problem and achieve at least 150/m gap distance between stimulation and recording sites by wet etched mirror surface in V-groove. Also, we developed light source, blue laser diode (OSRAM Blue Laser Diode_PL 450), integration through simple jig for one-touch butt-coupling. Furthermore, optical power and impedance of iridium oxide tetrodes were measured as 200 μW on 5 mW from LD and 206.5 k Ω at 1 kHz and we demonstrated insertion test of probe in 0.5% agarose-gel successfully. We have successfully transmitted a light of 450 nm to optical fiber through the integrated LD using by butt-coupling method.

  15. Contributed review: Review of integrated correlative light and electron microscopy.

    Science.gov (United States)

    Timmermans, F J; Otto, C

    2015-01-01

    New developments in the field of microscopy enable to acquire increasing amounts of information from large sample areas and at an increased resolution. Depending on the nature of the technique, the information may reveal morphological, structural, chemical, and still other sample characteristics. In research fields, such as cell biology and materials science, there is an increasing demand to correlate these individual levels of information and in this way to obtain a better understanding of sample preparation and specific sample properties. To address this need, integrated systems were developed that combine nanometer resolution electron microscopes with optical microscopes, which produce chemically or label specific information through spectroscopy. The complementary information from electron microscopy and light microscopy presents an opportunity to investigate a broad range of sample properties in a correlated fashion. An important part of correlating the differences in information lies in bridging the different resolution and image contrast features. The trend to analyse samples using multiple correlated microscopes has resulted in a new research field. Current research is focused, for instance, on (a) the investigation of samples with nanometer scale distribution of inorganic and organic materials, (b) live cell analysis combined with electron microscopy, and (c) in situ spectroscopic and electron microscopy analysis of catalytic materials, but more areas will benefit from integrated correlative microscopy.

  16. Contributed Review: Review of integrated correlative light and electron microscopy

    International Nuclear Information System (INIS)

    Timmermans, F. J.; Otto, C.

    2015-01-01

    New developments in the field of microscopy enable to acquire increasing amounts of information from large sample areas and at an increased resolution. Depending on the nature of the technique, the information may reveal morphological, structural, chemical, and still other sample characteristics. In research fields, such as cell biology and materials science, there is an increasing demand to correlate these individual levels of information and in this way to obtain a better understanding of sample preparation and specific sample properties. To address this need, integrated systems were developed that combine nanometer resolution electron microscopes with optical microscopes, which produce chemically or label specific information through spectroscopy. The complementary information from electron microscopy and light microscopy presents an opportunity to investigate a broad range of sample properties in a correlated fashion. An important part of correlating the differences in information lies in bridging the different resolution and image contrast features. The trend to analyse samples using multiple correlated microscopes has resulted in a new research field. Current research is focused, for instance, on (a) the investigation of samples with nanometer scale distribution of inorganic and organic materials, (b) live cell analysis combined with electron microscopy, and (c) in situ spectroscopic and electron microscopy analysis of catalytic materials, but more areas will benefit from integrated correlative microscopy

  17. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  18. RSAC, Gamma Doses, Inhalation and Ingestion Doses, Fission Products Inventory after Fission Products Release

    International Nuclear Information System (INIS)

    Richardson, L.C.

    1967-01-01

    1 - Description of problem or function: RSAC generates a fission product inventory from a given set of reactor operating conditions and then computes the external gamma dose, the deposition gamma dose, and the inhalation-ingestion dose to critical body organs as a result of exposure to these fission products. Program output includes reactor operating history, fission product inventory, dosages, and ingestion parameters. 2 - Method of solution: The fission product inventory generated by the reactor operating conditions and the inventory remaining at various times after release are computed using the equations of W. Rubinson in Journal of Chemical Physics, Vol. 17, pages 542-547, June 1949. The external gamma dose and the deposition gamma dose are calculated by determining disintegration rates as a function of space and time, then integrating using Hermite's numerical techniques for the spatial dependence. The inhalation-ingestion dose is determined by the type and quantity of activity inhaled and the biological rate of decay following inhalation. These quantities are integrated with respect to time to obtain the dosage. The ingestion dose is related to the inhalation dose by an input constant

  19. Integration of light and temperature in the regulation of circadian gene expression in Drosophila.

    Directory of Open Access Journals (Sweden)

    Catharine E Boothroyd

    2007-04-01

    together, these findings suggest that information from both light and temperature is integrated by the transcriptional clock mechanism in the adult fly head.

  20. Novel method based on Fricke gel dosimeters for dose verification in IMRT techniques

    International Nuclear Information System (INIS)

    Aon, E.; Brunetto, M.; Sansogne, R.; Castellano, G.; Valente, M.

    2008-01-01

    Modern radiotherapy is becoming increasingly complex. Conformal and intensity modulated (IMRT) techniques are nowadays available for achieving better tumour control. However, accurate methods for 3D dose verification for these modern irradiation techniques have not been adequately established yet. Fricke gel dosimeters consist, essentially, in a ferrous sulphate (Fricke) solution fixed to a gel matrix, which enables spatial resolution. A suitable radiochromic marker (xylenol orange) is added to the solution in order to produce radiochromic changes within the visible spectrum range, due to the chemical internal conversion (oxidation) of ferrous ions to ferric ions. In addition, xylenol orange has proved to slow down the internal diffusion effect of ferric ions. These dosimeters suitably shaped in form of thin layers and optically analyzed by means of visible light transmission imaging have recently been proposed as a method for 3D absorbed dose distribution determinations in radiotherapy, and tested in several IMRT applications employing a homogeneous plane (visible light) illuminator and a CCD camera with a monochromatic filter for sample analysis by means of transmittance images. In this work, the performance of an alternative read-out method is characterized, consisting on visible light images, acquired before and after irradiation by means of a commercially available flatbed-like scanner. Registered images are suitably converted to matrices and analyzed by means of dedicated 'in-house' software. The integral developed method allows performing 1D (profiles), 2D (surfaces) and 3D (volumes) dose mapping. In addition, quantitative comparisons have been performed by means of the Gamma composite criteria. Dose distribution comparisons between Fricke gel dosimeters and traditional standard dosimetric techniques for IMRT irradiations show an overall good agreement, supporting the suitability of the method. The agreement, quantified by the gamma index (that seldom

  1. Optical fiber sensor for low dose gamma irradiation monitoring

    Science.gov (United States)

    de Andrés, Ana I.; Esteban, Ã.`scar; Embid, Miguel

    2016-05-01

    An optical fiber gamma ray detector is presented in this work. It is based on a Terbium doped Gadolinium Oxysulfide (Gd2O2S:Tb) scintillating powder which cover a chemically etched polymer fiber tip. This etching improves the fluorescence gathering by the optical fiber. The final diameter has been selected to fulfill the trade-off between light gathering and mechanical strength. Powder has been encapsulated inside a microtube where the fiber tip is immersed. The sensor has been irradiated with different air Kerma doses up to 2 Gy/h with a 137Cs source, and the spectral distribution of the fluorescence intensity has been recorded in a commercial grade CCD spectrometer. The obtained signal-to-noise ratio is good enough even for low doses, which has allowed to reduce the integration time in the spectrometer. The presented results show the feasibility for using low cost equipment to detect/measure ionizing radiation as gamma rays are.

  2. Light, electron microscopic and immunohistochemical study of the effect of low-dose aspirin during the proestrus phase on rat endometrium in the preimplantation period.

    Science.gov (United States)

    Ateş, Utku; Baka, Meral; Turgut, Mehmet; Uyanikgil, Yiğit; Ulker, Sibel; Yilmaz, Ozlem; Tavmergen, Erol; Yurtseven, Mine

    2007-04-01

    To evaluate structural alterations in rat endometrium at preimplantation following treatment with aspirin beginning from proestrus by light microscopy, electron microscopy and immunohistochemical techniques. Twenty rats were divided into control (n = 10) and experimental (n = 10) groups. Experimental rats were treated with low-dose aspirin daily (2 mg/kg/day) during estrus, beginning from the proestrus phase, mated at end of cycle and treated with aspirin. Untreated pregnant rats were the control group. Rats in both groups were sacrificed at the 84th pregnancy hour; the uterus was rapidly removed and dissected free of surrounding adipose tissue. Uteri specimens from nonpregnant rats were transferred into fixative solution and processed for light, electron microscopic and immunohistochemical study. Light and electron microscopy of endometrium from control rats conformed to mid-diestrus phase; endometrial histology of the aspirin-treated group conformed to late diestrus phase. The endometrial layer was significantly thicker in the aspirin-treated group compared to the untreated control group (p <0.001). No significant difference was found in vessel number between groups. Staining with alphaV integrin was more dense in the aspirin-treated group. Based on histologic findings, we suggest low-dose aspirin has positive effects on preparing endometrium before implantation.

  3. Effect of clonal integration on nitrogen cycling in rhizosphere of rhizomatous clonal plant, Phyllostachys bissetii, under heterogeneous light.

    Science.gov (United States)

    Li, Yang; Chen, Jing-Song; Xue, Ge; Peng, Yuanying; Song, Hui-Xing

    2018-07-01

    Clonal integration plays an important role in clonal plant adapting to heterogeneous habitats. It was postulated that clonal integration could exhibit positive effects on nitrogen cycling in the rhizosphere of clonal plant subjected to heterogeneous light conditions. An in-situ experiment was conducted using clonal fragments of Phyllostachys bissetii with two successive ramets. Shading treatments were applied to offspring or mother ramets, respectively, whereas counterparts were treated to full sunlight. Rhizomes between two successive ramets were either severed or connected. Extracellular enzyme activities and nitrogen turnover were measured, as well as soil properties. Abundance of functional genes (archaeal or bacterial amoA, nifH) in the rhizosphere of shaded, offspring or mother ramets were determined using quantitative polymerase chain reaction. Carbon or nitrogen availabilities were significantly influenced by clonal integration in the rhizosphere of shaded ramets. Clonal integration significantly increased extracellular enzyme activities and abundance of functional genes in the rhizosphere of shaded ramets. When rhizomes were connected, higher nitrogen turnover (nitrogen mineralization or nitrification rates) was exhibited in the rhizosphere of shaded offspring ramets. However, nitrogen turnover was significantly decreased by clonal integration in the rhizosphere of shaded mother ramets. Path analysis indicated that nitrogen turnover in the rhizosphere of shaded, offspring or mother ramets were primarily driven by the response of soil microorganisms to dissolved organic carbon or nitrogen. This unique in-situ experiment provided insights into the mechanism of nutrient recycling mediated by clonal integration. It was suggested that effects of clonal integration on the rhizosphere microbial processes were dependent on direction of photosynthates transport in clonal plant subjected to heterogeneous light conditions. Copyright © 2018 Elsevier B.V. All rights

  4. Effects of a higher dose of near-infrared light on clinical signs and neuroprotection in a monkey model of Parkinson's disease.

    Science.gov (United States)

    Moro, Cécile; El Massri, Nabil; Darlot, Fannie; Torres, Napoleon; Chabrol, Claude; Agay, Diane; Auboiroux, Vincent; Johnstone, Daniel M; Stone, Jonathan; Mitrofanis, John; Benabid, Alim-Louis

    2016-10-01

    We have reported previously that intracranial application of near-infrared light (NIr) - when delivered at the lower doses of 25J and 35J - reduces clinical signs and offers neuroprotection in a subacute MPTP (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) monkey model of Parkinson's disease. In this study, we explored whether a higher NIr dose (125J) generated beneficial effects in the same MPTP monkey model (n=15). We implanted an NIr (670nm) optical fibre device within a midline region of the midbrain in macaque monkeys, close to the substantia nigra of both sides. MPTP injections (1.8-2.1mg/kg) were made over a five day period, during which time the NIr device was turned on and left on continuously throughout the ensuing three week survival period. Monkeys were evaluated clinically and their brains processed for immunohistochemistry and stereology. Our results showed that the higher NIr dose did not have any toxic impact on cells at the midbrain implant site. Further, this NIr dose resulted in a higher number of nigral tyrosine hydroxylase immunoreactive cells when compared to the MPTP group. However, the higher NIr dose monkeys showed little evidence for an increase in mean clinical score, number of nigral Nissl-stained cells and density of striatal tyrosine hydroxylase terminations. In summary, the higher NIr dose of 125J was not as beneficial to MPTP-treated monkeys as compared to the lower doses of 25J and 35J, boding well for strategies of NIr dose delivery and device energy consumption in a future clinical trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Benzoporphyrin derivative and light-emitting diode for use in photodynamic therapy: Applications of space light-emitting diode technology

    International Nuclear Information System (INIS)

    Whelan, Harry T.; Houle, John M.; Bajic, Dawn M.; Schmidt, Meic H.; Reichert, Kenneth W. II; Meyer, Glenn A.

    1998-01-01

    measured in these cell lines by tumor DNA synthesis reduction. The effectiveness of BPD against tumor cells in vitro thus established, we have taken the first step toward determining its effectiveness in vivo. The second part of this project consisted of experiments performed to determine the maximum tolerated dose (MTD) of both BPD and LED light. At a light dose of 100 J/cm 2 , skin damage and neurotoxicity were seen at a BPD dose of 1.0 mg/kg, but not at a dose of 0.75 mg/kg. When BPD remained constant at 0.75 mg/kg, skin damage was seen at light dosages of 125 J/cm 2 , 150 J/cm 2 and 175 J/cm 2 . One dog also died at a light dose of 175 J/cm 2 . Further studies will be needed to determine the effectiveness of BPD against tumor cells in vivo

  6. Approach to Low-Cost High-Efficiency OLED Lighting. Building Technologies Solid State Lighting (SSL) Program Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Qibing [Univ. of California, Los Angeles, CA (United States). Dept. of Materials Science and Engineering

    2017-10-06

    This project developed an integrated substrate which organic light emitting diode (OLED) panel developers could employ the integrated substrate to fabricate OLED devices with performance and projected cost meeting the MYPP targets of the Solid State Lighting Program of the Department of Energy. The project optimized the composition and processing conditions of the integrated substrate for OLED light extraction efficiency and overall performance. The process was further developed for scale up to a low-cost process and fabrication of prototype samples. The encapsulation of flexible OLEDs based on this integrated substrate was also investigated using commercial flexible barrier films.

  7. Integral Education in Light of Earthrise

    Directory of Open Access Journals (Sweden)

    Craig Chalquist

    2015-02-01

    Full Text Available This article explores the relationship between integral education and the emerging terrestrial consciousness—a consciousness of interdependency, sovereignty, and earthly responsibility. It asserts that integral education is well positioned at this time when urgent environmental catastrophes threaten our planet, to help us recover an integral relation with the universe and our planet Earth, and contribute to restoration of a sense of earthly wonder and reverence.

  8. Photoluminescence and reflectivity studies of high energy light ions irradiated polymethyl methacrylate films

    Science.gov (United States)

    Bharti, Madhu Lata; Singh, Fouran; Ramola, R. C.; Joshi, Veena

    2017-11-01

    The self-standing films of non-conducting polymethyl methacrylate (PMMA) were irradiated in vacuum using high energy light ions (HELIs) of 50 MeV Lithium (Li+3) and 80 MeV Carbon (C+5) at various ion dose to induce the optical changes in the films. Upon HELI irradiation, films exhibit a significant enhancement in optical reflectivity at the highest dose. Interestingly, the photoluminescence (PL) emission band with green light at (514.5 nm) shows a noticeable increase in the intensity with increasing ion dose for both ions. However, the rate of increase in PL intensity is different for both HELI and can be correlated with the linear energy transfer by these ions in the films. Origin of PL is attributed to the formation of carbon cluster and hydrogenated amorphous carbon in the polymer films. HAC clusters act as PL active centres with optical reflectivity. Most of the harmful radiation like UV are absorbed by the material and is becoming opaque after irradiation and this PL active material are useful in fabrication of optoelectronic devices, UV-filter, back-lit components in liquid crystal display systems, micro-components for integrate optical circuits, diffractive elements, advanced materials and are also applicable to the post irradiation laser treatment by means of ion irradiation.

  9. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  10. Metasurface integrated high energy efficient and high linearly polarized InGaN/GaN light emitting diode.

    Science.gov (United States)

    Wang, Miao; Xu, Fuyang; Lin, Yu; Cao, Bing; Chen, Linghua; Wang, Chinhua; Wang, Jianfeng; Xu, Ke

    2017-07-06

    We proposed and demonstrated an integrated high energy efficient and high linearly polarized InGaN/GaN green LED grown on (0001) oriented sapphire with combined metasurface polarizing converter and polarizer system. It is different from those conventional polarized light emissions generated with plasmonic metallic grating in which at least 50% high energy loss occurs inherently due to high reflection of the transverse electric (TE) component of an electric field. A reflecting metasurface, with a two dimensional elliptic metal cylinder array (EMCA) that functions as a half-wave plate, was integrated at the bottom of a LED such that the back-reflected TE component, that is otherwise lost by a dielectric/metal bi-layered wire grids (DMBiWG) polarizer on the top emitting surface of the LED, can be converted to desired transverse magnetic (TM) polarized emission after reflecting from the metasurface. This significantly enhances the polarized light emission efficiency. Experimental results show that extraction efficiency of the polarized emission can be increased by 40% on average in a wide angle of ±60° compared to that with the naked bottom of sapphire substrate, or 20% compared to reflecting Al film on the bottom of a sapphire substrate. An extinction ratio (ER) of average value 20 dB within an angle of ±60° can be simultaneously obtained directly from an InGaN/GaN LED. Our results show the possibility of simultaneously achieving a high degree of polarization and high polarization extraction efficiency at the integrated device level. This advances the field of GaN LED toward energy efficiency, multi-functional applications in illumination, display, medicine, and light manipulation.

  11. Light-like noncommutativity, light-front quantization and new light on UV/IR mixing

    International Nuclear Information System (INIS)

    Sheikh-Jabbari, M.M.; Tureanu, A.

    2011-01-01

    We revisit the problem of quantizing field theories on noncommutative Moyal space-time with light-like noncommutativity. To tackle the issues arising from noncommuting and hence nonlocal time, we argue that for this case light-front quantization procedure should be employed. In this appropriate quantization scheme we perform the non-planar loop analysis for the light-like noncommutative field theories. One of the important and peculiar features of light-front quantization is that the UV cutoff of the light-cone Hamiltonian manifests itself as an IR cutoff for the light-cone momentum, p + . Due to this feature, the naive results of covariant quantization for the light-like case allude to the absence of the UV/IR mixing in the light-front quantization. However, by a careful analysis of non-planar loop integrals we show that this is not the case and the UV/IR mixing persists. In addition, we argue in favour of the perturbative unitarity of light-like noncommutative field theories in the light-front quantization scheme.

  12. Text book of dose calculation for operators

    International Nuclear Information System (INIS)

    Aoyagi, Haruki; Gonda, Kozo

    1979-07-01

    This is a text book of dose calculation for the operators of the reprocessing factory of Power Reactor and Nuclear Fuel Development Corporation. The radiations considered are beta-ray and gamma-ray. The method used is a point attenuation nuclear integral method. Radiation sources are considered as the assemblies of point sources. Dose from each point source is calculated, then, total dose is obtained by the integration for all sources. Attenuation is calculated by considering the attenuation owing to distance and the absorption by absorbers. The build-up factor is introduced for the correction for scattered gamma-ray. The build-up factor is given in a table for various scatterers. The operators are able to calculate dose by themselves. The results of integral calculation expressed with formulas are given in graphs. (Kato, T.)

  13. Light emitting fabric technologies for photodynamic therapy.

    Science.gov (United States)

    Mordon, Serge; Cochrane, Cédric; Tylcz, Jean Baptiste; Betrouni, Nacim; Mortier, Laurent; Koncar, Vladan

    2015-03-01

    Photodynamic therapy (PDT) is considered to be a promising method for treating various types of cancer. A homogeneous and reproducible illumination during clinical PDT plays a determinant role in preventing under- or over-treatment. The development of flexible light sources would considerably improve the homogeneity of light delivery. The integration of optical fiber into flexible structures could offer an interesting alternative. This paper aims to describe different methods proposed to develop Side Emitting Optical Fibers (SEOF), and how these SEOF can be integrated in a flexible structure to improve light illumination of the skin during PDT. Four main techniques can be described: (i) light blanket integrating side-glowing optical fibers, (ii) light emitting panel composed of SEOF obtained by micro-perforations of the cladding, (iii) embroidery-based light emitting fabric, and (iv) woven-based light emitting fabric. Woven-based light emitting fabrics give the best performances: higher fluence rate, best homogeneity of light delivery, good flexibility. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Wound healing stimulation in mice by low-level light

    Science.gov (United States)

    Demidova, Tatiana N.; Herman, Ira M.; Salomatina, Elena V.; Yaroslavsky, Anna N.; Hamblin, Michael R.

    2006-02-01

    It has been known for many years that low levels of laser or non-coherent light (LLLT) accelerate some phases of wound healing. LLLT can stimulate fibroblast and keratinocyte proliferation and migration. It is thought to work via light absorption by mitochondrial chromophores leading to an increase in ATP, reactive oxygen species and consequent gene transcription. However, despite many reports about the positive effects of LLLT on wound healing, its use remains controversial. Our laboratory has developed a model of a full thickness excisional wound in mice that allows quantitative and reproducible light dose healing response curves to be generated. We have found a biphasic dose response curve with a maximum positive effect at 2 J/cm2 of 635-nm light and successively lower beneficial effects from 3-25 J/cm2, the effect is diminished at doses below 2J/cm2 and gradually reaches control healing levels. At light doses above 25 J/cm2 healing is actually worse than controls. The two most effective wavelengths of light were found to be 635 and 820-nm. We found no difference between filtered 635+/-15-nm light from a lamp and 633-nm light from a HeNe laser. The strain and age of the mouse affected the magnitude of the effect. Light treated wounds start to contract after illumination while control wounds initially expand for the first 24 hours. Our hypothesis is that a single brief light exposure soon after wounding affects fibroblast cells in the margins of the wound. Cells may be induced to proliferate, migrate and assume a myofibroblast phenotype. Our future work will be focused on understanding the mechanisms underlying effects of light on wound healing processes.

  15. Concept of white light in stage lighting

    Science.gov (United States)

    Rinaldi, Mauricio R.

    2002-06-01

    In perceiving objects, generally we see them in a white light situation. But, actually, there is not an absolute white, in such a manner that the different light sources have a determined kind of white, what it is known as color temperature. Even the white light may be of different kinds (different color temperature), the individual mind tends to perceive it as the same kind of white, that is to say, there is in our mind a psychological function by which we operate an integration in the perception in order to do the object perceptually invariable. On the other hand, it is a common practice in stage lighting to use color light sources. It is a well known phenomenon that a color of light produces a change in the object color perception. However, when we go to theater, we see the objects as having their real color, even if the lighting is not white. In this paper the concept of white light in stage lighting is presented, showing its possibilities of aesthetical expression.

  16. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients

    International Nuclear Information System (INIS)

    Penoncello, Gregory P.; Ding, George X.

    2016-01-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2 cm"3 for head and neck plans and brain plans and a contiguous volume of 5 cm"3 for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens.

  17. Dose-dependent responses of avian daily rhythms to artificial light at night

    NARCIS (Netherlands)

    De Jong, M.; Jeninga, L.; Ouyang, Jenny; van Oers, K.; Spoelstra, K.; Visser, M.E.

    2016-01-01

    Recent studies have shown that animals are affected by night-time light exposure. Light is a continuous variable, but our knowledge on how individuals react to different light intensities during the night is limited. We therefore determined the relationship between night light intensity and the

  18. Dose-dependent responses of avian daily rhythms to artificial light at night

    NARCIS (Netherlands)

    de Jong, Maaike; Jeninga, Lizanne; Ouyang, Jenny Q; van Oers, Kees; Spoelstra, Kamiel; Visser, Marcel E

    2015-01-01

    Recent studies have shown that animals are affected by night-time light exposure. Light is a continuous variable, but our knowledge on how individuals react to different light intensities during the night is limited. We therefore determined the relationship between night light intensity and the

  19. Differences in micronucleus induction in peripheral blood reticulocytes of mice exposed to N-ethyl-N-nitrosourea at light and dark dosing times.

    Science.gov (United States)

    Itoh, Keiichi; Masumori, Shoji; Nakajima, Madoka; Hayashi, Makoto; Sakakibara, Hiroyuki; Shimoi, Kayoko

    2012-01-01

    Mammals, including human beings, have a circadian clock system to regulate behavioral and physiological processes. In this study, we investigated the effect of dosing time on micronucleus induction in the bone marrow by evaluating the frequencies of micronucleated peripheral reticulocytes (MNRETs) in mice exposed to N-ethyl-N-nitrosourea (ENU) to assess any difference in genotoxic sensitivity to chemicals between light and dark periods (inactive phase for rodents and active phase for rodents). Male C3H/He mice were treated intraperitoneally with ENU (12.5 or 25 mg/kg body weight) at zeitgeber time (ZT) 3 in the light period or ZT15 in the dark period, and then the time courses of the frequencies of the MNRETs were determined. The frequencies of the MNRETs induced by ENU increased time-dependently and peaked at 48 hr after treatment for ZT3 and ZT15, and were obviously higher in the ZT15 treatment group than the ZT3 treatment group. The MNRETs were measured at 48 hr after treatment with ENU (25 mg/kg body weight) at various dosing times (ZT0, 3, 6, 12, 15 and 18). The frequencies of the MNRETs in mice treated at ZT0, 15 and 18 were significantly higher than those in mice treated at ZT3, 6 and 12. These results suggest that genotoxic sensitivity to chemicals in mouse bone marrow is different between light and dark periods maybe due to different biological responses (detoxification, cell cycle, DNA repair, etc.) related to circadian rhythms.

  20. Towards an Integrated QR Code Biosensor: Light-Driven Sample Acquisition and Bacterial Cellulose Paper Substrate.

    Science.gov (United States)

    Yuan, Mingquan; Jiang, Qisheng; Liu, Keng-Ku; Singamaneni, Srikanth; Chakrabartty, Shantanu

    2018-06-01

    This paper addresses two key challenges toward an integrated forward error-correcting biosensor based on our previously reported self-assembled quick-response (QR) code. The first challenge involves the choice of the paper substrate for printing and self-assembling the QR code. We have compared four different substrates that includes regular printing paper, Whatman filter paper, nitrocellulose membrane and lab synthesized bacterial cellulose. We report that out of the four substrates bacterial cellulose outperforms the others in terms of probe (gold nanorods) and ink retention capability. The second challenge involves remote activation of the analyte sampling and the QR code self-assembly process. In this paper, we use light as a trigger signal and a graphite layer as a light-absorbing material. The resulting change in temperature due to infrared absorption leads to a temperature gradient that then exerts a diffusive force driving the analyte toward the regions of self-assembly. The working principle has been verified in this paper using assembled biosensor prototypes where we demonstrate higher sample flow rate due to light induced thermal gradients.

  1. Dose rate estimates from irradiated light-water-reactor fuel assemblies in air

    International Nuclear Information System (INIS)

    Lloyd, W.R.; Sheaffer, M.K.; Sutcliffe, W.G.

    1994-01-01

    It is generally considered that irradiated spent fuel is so radioactive (self-protecting) that it can only be moved and processed with specialized equipment and facilities. However, a small, possibly subnational, group acting in secret with no concern for the environment (other than the reduction of signatures) and willing to incur substantial but not lethal radiation doses, could obtain plutonium by stealing and processing irradiated spent fuel that has cooled for several years. In this paper, we estimate the dose rate at various distances and directions from typical pressurized-water reactor (PWR) and boiling-water reactor (BWR) spent-fuel assemblies as a function of cooling time. Our results show that the dose rate is reduced rapidly for the first ten years after exposure in the reactor, and that it is reduced by a factor of ∼10 (from the one year dose rate) after 15 years. Even for fuel that has cooled for 15 years, a lethal dose (LD50) of 450 rem would be received at 1 m from the center of the fuel assembly after several minutes. However, moving from 1 to 5 m reduces the dose rate by over a factor of 10, and moving from 1 to 10 m reduces the dose rate by about a factor of 50. The dose rates 1 m from the top or bottom of the assembly are considerably less (about 10 and 22%, respectively) than 1 m from the center of the assembly, which is the direction of the maximum dose rate

  2. Dose-dependent responses of avian daily rhythms to artificial light at night

    NARCIS (Netherlands)

    Jong, de M.; Jeninga, L.; Ouyang, J.Q.; Oers, van K.; Spoelstra, K.; Visser, M.E.

    2016-01-01

    Recent studies have shown that animals are affected by night-time light exposure. Light is a continuous variable, but our knowledge on how individuals react to different light intensities during the night is limited. We therefore determined the relationship between night light intensity and the

  3. Adaptive integration of daylight and artificial lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve

    2016-01-01

    Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between the space inside and the world outside. The aperture or window itself constitutes the frame...... with the world. In contrast to fluctuating daylight, a specific distinctive feature of artificial light has been – until very recently – its constancy in colour and intensity. However, by virtue of the technological convertibility of LEDs in concert with digital control systems, LEDs are capable of dynamically...... producing variations in colour and intensity in ways that correspond to our experiences of the daylight. Daylight and artificial lighting are thus positioned in a new relationship to one another. Metaphorically, one can think of the adaptive software as ‘digital weather’ – as a self-generating and shifting...

  4. INFRARED HIGH-RESOLUTION INTEGRATED LIGHT SPECTRAL ANALYSES OF M31 GLOBULAR CLUSTERS FROM APOGEE

    Energy Technology Data Exchange (ETDEWEB)

    Sakari, Charli M. [Department of Astronomy, University of Washington, Seattle WA 98195-1580 (United States); Shetrone, Matthew D. [McDonald Observatory, University of Texas at Austin, HC75 Box 1337-MCD, Fort Davis, TX 79734 (United States); Schiavon, Ricardo P. [Gemini Observatory, 670 N. A’Ohoku Place, Hilo, HI 96720 (United States); Bizyaev, Dmitry; Pan, Kaike [Apache Point Observatory and New Mexico State University, P.O. Box 59, Sunspot, NM, 88349-0059 (United States); Prieto, Carlos Allende; García-Hernández, Domingo Aníbal [Instituto de Astrofísica de Canarias (IAC), Va Lactea s/n, E-38205 La Laguna, Tenerife (Spain); Beers, Timothy C. [Department of Physics and JINA Center for the Evolution of the Elements, University of Notre Dame, Notre Dame, IN 46556 (United States); Caldwell, Nelson [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Lucatello, Sara [INAF Osservatorio Astronomico di Padova, Vicolo dellOsservatorio 5, I-35122 Padova (Italy); Majewski, Steven; O’Connell, Robert W. [Dept. of Astronomy, University of Virginia, Charlottesville, VA 22904-4325 (United States); Strader, Jay, E-mail: sakaricm@u.washington.edu [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States)

    2016-10-01

    Chemical abundances are presented for 25 M31 globular clusters (GCs), based on moderately high resolution ( R = 22,500) H -band integrated light (IL) spectra from the Apache Point Observatory Galactic Evolution Experiment (APOGEE). Infrared (IR) spectra offer lines from new elements, lines of different strengths, and lines at higher excitation potentials compared to the optical. Integrated abundances of C, N, and O are derived from CO, CN, and OH molecular features, while Fe, Na, Mg, Al, Si, K, Ca, and Ti abundances are derived from atomic features. These abundances are compared to previous results from the optical, demonstrating the validity and value of IR IL analyses. The CNO abundances are consistent with typical tip of the red giant branch stellar abundances but are systematically offset from optical Lick index abundances. With a few exceptions, the other abundances agree between the optical and the IR within the 1 σ uncertainties. The first integrated K abundances are also presented and demonstrate that K tracks the α elements. The combination of IR and optical abundances allows better determinations of GC properties and enables probes of the multiple populations in extragalactic GCs. In particular, the integrated effects of the Na/O anticorrelation can be directly examined for the first time.

  5. Red versus blue light illumination in hexyl 5-aminolevulinate photodynamic therapy: the influence of light color and irradiance on the treatment outcome in vitro

    Science.gov (United States)

    Helander, Linda; Krokan, Hans E.; Johnsson, Anders; Gederaas, Odrun A.; Plaetzer, Kristjan

    2014-08-01

    Hexyl 5-aminolevulinate (HAL) is a lipophilic derivative of 5-aminolevulinate, a key intermediate in biosynthesis of the photosensitizer protoporphyrin IX (PpIX). The photodynamic efficacy and cell death mode after red versus blue light illumination of HAL-induced PpIX have been examined and compared using five different cancer cell lines. LED arrays emitting at 410 and 624 nm served as homogenous and adjustable light sources. Our results show that the response after HAL-PDT is cell line specific, both regarding the shape of the dose-survival curve, the overall dose required for efficient cell killing, and the relative amount of apoptosis. The ratio between 410 and 624 nm in absorption coefficient correlates well with the difference in cell killing at the same wavelengths. In general, the PDT efficacy was several folds higher for blue light as compared with red light, as expected. However, HAL-PDT624 induced more apoptosis than HAL-PDT410 and illumination with low irradiance resulted in more apoptosis than high irradiance at the same lethal dose. This indicates differences in death modes after low and high irradiance after similar total light doses. From a treatment perspective, these differences may be important.

  6. Red versus blue light illumination in hexyl 5-aminolevulinate photodynamic therapy: the influence of light color and irradiance on the treatment outcome in vitro.

    Science.gov (United States)

    Helander, Linda; Krokan, Hans E; Johnsson, Anders; Gederaas, Odrun A; Plaetzer, Kristjan

    2014-08-01

    Hexyl 5-aminolevulinate (HAL) is a lipophilic derivative of 5-aminolevulinate, a key intermediate in biosynthesis of the photosensitizer protoporphyrin IX (PpIX). The photodynamic efficacy and cell death mode after red versus blue light illumination of HAL-induced PpIX have been examined and compared using five different cancer cell lines. LED arrays emitting at 410 and 624 nm served as homogenous and adjustable light sources. Our results show that the response after HAL-PDT is cell line specific, both regarding the shape of the dose-survival curve, the overall dose required for efficient cell killing, and the relative amount of apoptosis. The ratio between 410 and 624 nm in absorption coefficient correlates well with the difference in cell killing at the same wavelengths. In general, the PDT efficacy was several folds higher for blue light as compared with red light, as expected. However, HAL-PDT₆₂₄ induced more apoptosis than HAL-PDT₄₁₀ and illumination with low irradiance resulted in more apoptosis than high irradiance at the same lethal dose. This indicates differences in death modes after low and high irradiance after similar total light doses. From a treatment perspective, these differences may be important.

  7. Exquisite light sensitivity of Drosophila melanogaster cryptochrome.

    Directory of Open Access Journals (Sweden)

    Pooja Vinayak

    Full Text Available Drosophila melanogaster shows exquisite light sensitivity for modulation of circadian functions in vivo, yet the activities of the Drosophila circadian photopigment cryptochrome (CRY have only been observed at high light levels. We studied intensity/duration parameters for light pulse induced circadian phase shifts under dim light conditions in vivo. Flies show far greater light sensitivity than previously appreciated, and show a surprising sensitivity increase with pulse duration, implying a process of photic integration active up to at least 6 hours. The CRY target timeless (TIM shows dim light dependent degradation in circadian pacemaker neurons that parallels phase shift amplitude, indicating that integration occurs at this step, with the strongest effect in a single identified pacemaker neuron. Our findings indicate that CRY compensates for limited light sensitivity in vivo by photon integration over extraordinarily long times, and point to select circadian pacemaker neurons as having important roles.

  8. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  9. The effect of low dose ionizing radiation on homeostasis and functional integrity in an organotypic human skin model

    Energy Technology Data Exchange (ETDEWEB)

    Neubeck, Claere von [German Cancer Consortium DKTK partner site Dresden, OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, 01307 Dresden (Germany); German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Geniza, Matthew J. [Molecular and Cellular Biology Program, Oregon State University, Corvallis OR 97331 (United States); Kauer, Paula M.; Robinson, R. Joe; Chrisler, William B. [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland WA 99352 (United States); Sowa, Marianne B., E-mail: marianne.sowa@pnnl.gov [Health Impacts and Exposure Science, Pacific Northwest National Laboratory, Richland WA 99352 (United States)

    2015-05-15

    Highlights: • Low doses of high LET radiation influence skin homeostasis. • Effects on proliferation and differentiation profiles are LET dependent. • Skin barrier function is not compromised following low dose exposure. - Abstract: Outside the protection of Earth's atmosphere, astronauts are exposed to low doses of high linear energy transfer (LET) radiation. Future NASA plans for deep space missions or a permanent settlement on the moon are limited by the health risks associated with space radiation exposures. There is a paucity of direct epidemiological data for low dose exposures to space radiation-relevant high LET ions. Health risk models are used to estimate the risk for such exposures, though these models are based on high dose experiments. There is increasing evidence, however, that low and high dose exposures result in different signaling events at the molecular level, and may involve different response mechanisms. Further, despite their low abundance, high LET particles have been identified as the major contributor to health risk during manned space flight. The human skin is exposed in every external radiation scenario, making it an ideal epithelial tissue model in which to study radiation induced effects. Here, we exposed an in vitro three dimensional (3-D) human organotypic skin tissue model to low doses of high LET oxygen (O), silicon (Si) and iron (Fe) ions. We measured proliferation and differentiation profiles in the skin tissue and examined the integrity of the skin's barrier function. We discuss the role of secondary particles in changing the proportion of cells receiving a radiation dose, emphasizing the possible impact on radiation-induced health issues in astronauts.

  10. Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography

    Science.gov (United States)

    Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang

    2017-10-01

    Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.

  11. Adaptive Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin; Kongshaug, Jesper

    2015-01-01

    the investigations of lighting scenarios carried out in two test installations: White Cube and White Box. The test installations are discussed as large-scale experiential instruments. In these test installations we examine what could potentially occur when light using LED technology is integrated and distributed......Adaptive Lighting Adaptive lighting is based on a partial automation of the possibilities to adjust the colour tone and brightness levels of light in order to adapt to people’s needs and desires. IT support is key to the technical developments that afford adaptive control systems. The possibilities...... differently into an architectural body. We also examine what might occur when light is dynamic and able to change colour, intensity and direction, and when it is adaptive and can be brought into interaction with its surroundings. In short, what happens to an architectural space when artificial lighting ceases...

  12. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  13. Evaluation of the Effects of Integrated Management Weed Control on Corn Field by Using Reduced Dose of Foramsulfuron and Nicosulfuron Herbicides

    Directory of Open Access Journals (Sweden)

    M. Matinfar

    2011-09-01

    Full Text Available In order to evaluate the effects of integrated weed management on weed control by using reduced herbicide dose, a field experiment was conducted in 2010 in Qazvin. The experiment was conducted in randomized complete block design with 24 treatments and 4 replications. The treatments were: different planting patterns at three levels (single row, square double rows and zigzag double row  plantings and doses of  Nicosulfuron and Foramsulfuron application at four levels (1, 1/5, 2 and 2/5 liters per hectare, The results showed that among the different planting patterns, zigzag planting reduced weed populations and their dry weights significantly. Foramsulfuron herbicide could control weeds better than Nicosulfuron. Among the herbicide dosages, 2/5 litter dose per hectare highly reduced weed density its dry weight as compared to one litter dose.

  14. Massive planar and non-planar double box integrals for light N f contributions to

    Science.gov (United States)

    von Manteuffel, Andreas; Studerus, Cedric

    2013-10-01

    We present the master integrals needed for the light fermionic two-loop corrections to top quark pair production in the gluon fusion channel. Via the method of differential equations we compute the results in terms of multiple polylogarithms in a Laurent series about d = 4, where d is the space-time dimension. The most involved topology is a non-planar double box with one internal mass. We employ the coproduct-augmented symbol calculus and show that significant simplifications are possible for selected results using an optimised set of multiple polylogarithms.

  15. Visual Cycle Modulation as an Approach toward Preservation of Retinal Integrity.

    Directory of Open Access Journals (Sweden)

    Claes Bavik

    Full Text Available Increased exposure to blue or visible light, fluctuations in oxygen tension, and the excessive accumulation of toxic retinoid byproducts places a tremendous amount of stress on the retina. Reduction of visual chromophore biosynthesis may be an effective method to reduce the impact of these stressors and preserve retinal integrity. A class of non-retinoid, small molecule compounds that target key proteins of the visual cycle have been developed. The first candidate in this class of compounds, referred to as visual cycle modulators, is emixustat hydrochloride (emixustat. Here, we describe the effects of emixustat, an inhibitor of the visual cycle isomerase (RPE65, on visual cycle function and preservation of retinal integrity in animal models. Emixustat potently inhibited isomerase activity in vitro (IC50 = 4.4 nM and was found to reduce the production of visual chromophore (11-cis retinal in wild-type mice following a single oral dose (ED50 = 0.18 mg/kg. Measure of drug effect on the retina by electroretinography revealed a dose-dependent slowing of rod photoreceptor recovery (ED50 = 0.21 mg/kg that was consistent with the pattern of visual chromophore reduction. In albino mice, emixustat was shown to be effective in preventing photoreceptor cell death caused by intense light exposure. Pre-treatment with a single dose of emixustat (0.3 mg/kg provided a ~50% protective effect against light-induced photoreceptor cell loss, while higher doses (1-3 mg/kg were nearly 100% effective. In Abca4-/- mice, an animal model of excessive lipofuscin and retinoid toxin (A2E accumulation, chronic (3 month emixustat treatment markedly reduced lipofuscin autofluorescence and reduced A2E levels by ~60% (ED50 = 0.47 mg/kg. Finally, in the retinopathy of prematurity rodent model, treatment with emixustat during the period of ischemia and reperfusion injury produced a ~30% reduction in retinal neovascularization (ED50 = 0.46mg/kg. These data demonstrate the ability of

  16. Fiber optical dose rate measurement based on the luminescence of beryllium oxide

    Directory of Open Access Journals (Sweden)

    Teichmann Tobias

    2018-01-01

    Full Text Available This work presents a fiber optical dose rate measurement system based on the radioluminescence and optically stimulated luminescence of beryllium oxide. The system consists of a small, radiation sensitive probe which is coupled to a light detection unit with a long and flexible light guide. Exposing the beryllium oxide probe to ionizing radiation results in the emission of light with an intensity which is proportional to the dose rate. Additionally, optically stimulated luminescence can be used to obtain dose and dose rate information during irradiation or retrospectively. The system is capable of real time dose rate measurements in fields of high dose rates and dose rate gradients and in complex, narrow geometries. This enables the application for radiation protection measurements as well as for quality control in radiotherapy. One inherent drawback of fiber optical dosimetry systems is the generation of Cherenkov radiation and luminescence in the light guide itself when it is exposed to ionizing radiation. This so called “stem” effect leads to an additional signal which introduces a deviation in the dose rate measurement and reduces the spatial resolution of the system, hence it has to be removed. The current system uses temporal discrimination of the effect for radioluminescence measurements in pulsed radiation fields and modulated optically stimulated luminescence for continuous irradiation conditions. This work gives an overview of the major results and discusses new-found obstacles of the applied methods of stem discrimination.

  17. Light-based therapy on wound healing : a review

    International Nuclear Information System (INIS)

    Suan, Lau Pik; Bidin, Noriah; Cherng, Chong Jia; Hamid, Asmah

    2014-01-01

    Wound healing is a complex matrix and overlapping process. In order to accelerate the healing process and minimize bacterial infection, light-based therapy was applied to stimulate bio-reaction to improve healing. The aim of this paper is to review the effects induced by light source (laser and incoherent light like LED) on different biological targets. The light-based therapy techniques were categorized according to the wavelength, energy density, type of irradiance and activity of tissues in the healing process. Out of 80 cases, 77% were animal studies, 5% were human studies and 18% were cell studies. Around 75% of light-based therapy has an advantage on tissue interaction and 25% has no effect or inhibition on the healing process. The appropriate dose appears to be between 1 and 5 J cm −2 . At shorter wavelength, photobiostimulation would be effective with a high frequently administrated low-energy dose. On the other hand, for longer wavelength it is the reverse, i.e., more effective with a low frequent treated schedule and a high-energy dose. (topical reviews)

  18. Overview of Graphical User Interface for ARRBOD (Acute Radiation Risk and BRYNTRN Organ Dose Projection)

    Science.gov (United States)

    Kim, Myung-Hee Y.; Hu, Shaowen; Nounu, Hatem N.; Cucinotta, Francis A.

    2010-01-01

    Solar particle events (SPEs) pose the risk of acute radiation sickness (ARS) to astronauts, because organ doses from large SPEs may reach critical levels during extra vehicular activities (EVAs) or lightly shielded spacecraft. NASA has developed an organ dose projection model of Baryon transport code (BRYNTRN) with an output data processing module of SUMDOSE, and a probabilistic model of acute radiation risk (ARR). BRYNTRN code operation requires extensive input preparation, and the risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. With a graphical user interface (GUI) to handle input and output for BRYNTRN, these response models can be connected easily and correctly to BRYNTRN in a user friendly way. The GUI for the Acute Radiation Risk and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations required for operations of the ARRBOD modules: BRYNTRN, SUMDOSE, and the ARR probabilistic response model. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. Assessment of astronauts organ doses and ARS from the exposure to historically large SPEs is in support of mission design and operation planning to avoid ARS and stay within the current NASA short-term dose limits. The ARRBOD GUI will serve as a proof-of-concept for future integration of other risk projection models for human space applications. We present an overview of the ARRBOD GUI product, which is a new self-contained product, for the major components of the overall system, subsystem interconnections, and external interfaces.

  19. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.; Uneri, A.; Stayman, J. W.; Zbijewski, W.; Schmidgunst, C.; Kleinszig, G.; Khanna, A. J.; Siewerdsen, J. H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Siemens Healthcare XP Division, Erlangen (Germany); Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland 21239 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 and Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2011-08-15

    Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter

  20. Solar concentrator with integrated tracking and light delivery system with collimation

    Science.gov (United States)

    Maxey, Lonnie Curt

    2015-06-09

    A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector directs the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and distributes light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting, uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

  1. Solar concentrator with integrated tracking and light delivery system with summation

    Science.gov (United States)

    Maxey, Lonnie Curt

    2015-05-05

    A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector redirects the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and provides light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting that uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

  2. Committed equivalent organ doses and committed effective doses from intakes of radionuclides

    CERN Document Server

    Phipps, A W; Kendall, G M; Silk, T J; Stather, J W

    1991-01-01

    This report contains details of committed equivalent doses to individual organs for intakes by ingestion and inhalation of 1 mu m AMAD particles of 359 nuclides by infants aged 3 months, by children aged 1, 5, 10 and 15 years, and by adults. It complements NRPB-R245 which describes the changes which have taken place since the last NRPB compendium of dose per unit intake factors (dose coefficients) and gives summary tables. Information on the way committed doses increase with the integration period is given in NRPB-M289. The information given in these memoranda is also available as a microcomputer package - NRPB-SR245.

  3. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients.

    Science.gov (United States)

    Penoncello, Gregory P; Ding, George X

    2016-01-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2cm(3) for head and neck plans and brain plans and a contiguous volume of 5cm(3) for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens. Copyright © 2016 American Association of Medical Dosimetrists. Published by

  4. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  5. Kinetic and dose dependencies of the SOS-induction in E.coli K-12 (uvrA) cells exposed to different UV doses

    International Nuclear Information System (INIS)

    Komova, O.V.; Kandiano, E.S.; Malavina, G.; )

    2000-01-01

    Kinetic and dose dependencies of the SOS-induction in E. coli (uvrA) cells exposed to UV light were investigated. below 2 J/m 2 the rate of the SOS-induction increased with dose. Maximal level of the SOS-response was proportional to the UV dose. Pyrimidine dimers were necessary for the induction. In the dose range 2-10 J/m 2 the rate of SOS-induction decreased with dose. Dose-maximum response curve was non-linear. Pyrimidine dimers were not required for the induction. nature of the molecular events leading to the SOS-induction at low and high doses was discussed [ru

  6. Light Rhythms in Architecture

    DEFF Research Database (Denmark)

    Bülow, Katja

    2013-01-01

    On one hand, urban lighting expresses itself in a complex visual environment made by the interplay by between many separate lighting schemes, as street lighting, shop lighting, luminous commercials etc. On the other, a noticeable order of patterns occurs, when lighting is observed as luminous...... formation and rhythm. When integrated into an architectural concept, electrical lighting non-intended for poetic composition has the ability to contribute to place, time, and function-telling aspects of places in urban contexts. Urban environments are information wise challenging to pre-historic human...... instincts, but they can be met by careful selection and adjustment of existing light situations....

  7. Hybrid daylight/light-emitting diode illumination system for indoor lighting.

    Science.gov (United States)

    Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei

    2014-03-20

    A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.

  8. Improved estimates of external gamma dose rates in the environs of Hinkley Point Power Station

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Thompson, I.M.G.

    1988-07-01

    The dominant source of external gamma dose rates at centres of population within a few kilometres of Hinkley Point Power Station is the routine discharge of 41-Ar from the 'A' station magnox reactors. Earlier estimates of the 41-Ar radiation dose rates were based upon measured discharge rates, combined with calculations using standard plume dispersion and cloud-gamma integration models. This report presents improved dose estimates derived from environmental gamma dose rate measurements made at distances up to about 1 km from the site, thus minimising the degree of extrapolation introduced in estimating dose rates at locations up to a few kilometres from the site. In addition, results from associated chemical tracer measurements and wind tunnel simulations covering distances up to about 4 km from the station are outlined. These provide information on the spatial distribution of the 41-Ar plume during the initial stages of its dispersion, including effects due to plume buoyancy and momentum and behaviour under light wind conditions. In addition to supporting the methodology used for the 41-Ar dose calculations, this information is also of generic interest in the treatment of a range of operational and accidental releases from nuclear power station sites and will assist in the development and validation of existing environmental models. (author)

  9. Array of organic thin film transistors integrated with organic light emitting diodes on a plastic substrate

    International Nuclear Information System (INIS)

    Ryu, Gi-Seong; Choe, Ki-Beom; Song, Chung-Kun

    2006-01-01

    In order to demonstrate the possible application of an organic thin film transistor (OTFT) to a flexible active matrix organic light emitting diode (OLED) an array of 64 x 64 pixels was fabricated on a 4-in. size poly-ethylene-terephehalate substrate. Each pixel was composed of one OTFT integrated with one OLED. OTFTs successfully drove OLEDs by varying current in a wide range and some images were displayed on the array by emitting green light. The OTFTs used poly(4-vinylphenol) for the gate and pentacene for the semiconductor taking account compatibility with the PET substrate. The average mobility in the array was 0.2 cm 2 /V.s, which was reduced from 1.0 cm 2 /V.s in a single OTFT, and its variation over the entire substrate was 10%

  10. Note: A portable Raman analyzer for microfluidic chips based on a dichroic beam splitter for integration of imaging and signal collection light paths

    Energy Technology Data Exchange (ETDEWEB)

    Geng, Yijia; Xu, Shuping; Xu, Weiqing, E-mail: xuwq@jlu.edu.cn [State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University, Changchun 130012 (China); Chen, Lei [State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University, Changchun 130012 (China); College of Physics, Jilin University, Changchun 130012 (China); Chen, Gang [State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University, Changchun 130012 (China); College of Chemistry, Jilin University, Changchun 130012 (China); Bi, Wenbin [State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University, Changchun 130012 (China); School of Chemistry and Environmental Engineering, Changchun University of Science and Technology, Changchun 130022 (China); Cui, Haining [College of Physics, Jilin University, Changchun 130012 (China)

    2015-05-15

    An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.

  11. The influence of various doses of phosphorus and of the addition of calcium or potassium fertilization upon the yield of tomatoes in Wrocław hydroponic culture using two intensities of light

    Directory of Open Access Journals (Sweden)

    Z. Gumicka

    2013-12-01

    Full Text Available Two experiments were carried out with phosphate fertilization of tomatoes in hydroponic culture. It has been proved that an additional dose of phosphorus given during the second cluster bloom, caused an yield increase. The optimal dose is 12 g of superphosphate (16% P2O5 per plant. The "green back" symptoms did not appear in these conditions. The parallel additional applying of calcium or potassium gave a decrease of the yield. When the light intensity was lowered to about 50%, the yield has decreased by half. In these conditions an additional applying of calcium (0,4 g CaCO3 and phosphorus (1g superphosphate annulated the negative influence of the low light intensity.

  12. The Effects of Different Light Qualities on Gamma Ray-Treated Scenedesmus

    Directory of Open Access Journals (Sweden)

    Adoracion Arañez

    1992-06-01

    Full Text Available Unialgal culture of Scenedesmus quadricauda (Turp. Breb. suspended in distilled water was treated with 0 Gy (control, 40 Gy, 80 Gy, and 120 Gy gamma rays from a to 60Co source at Philippine Nuclear Research Institute, placed in one-liter flasks, enough Bold basal medium added to give a transmittance of 97% determined by using a spectrophotometer, kept in the dark for 24 hrs., then placed in vials and distributed equally in three growth chambers with white light, red light, and blue light. The lighting was continuous with algae subjected to the same light intensity, and the temperature maintained at 30±1° C. A sterile regimen was followed.For the first two weeks, the growth rates of algae under white light were highest, followed by those under red light, while those grown under blue light had the lowest growth rate. After the second week, differences in growth rates were not significant anymore. During the first week, generally low doses of gamma radiation had stimulating effects on growth rates while high doses had inhibitory effects on growth. The abnormal Scenedesmus observed were enlarged cells of normal shape in coenobia of two cells and four cells, enlarged cells that were not forming coenobia, coenobia composed of enlarged cells of abnormal shape, coenobia composed of enlarged cells of different sizes, cells with kidney-shape chloroplast, coenobia with cells that were not in alignment as in the normal ones, and cells that were colorless. Percentage of coenobia with enlarged cells determined one week after the treatment showed that higher doses generally produced more enlarged cells than lower doses. Treated algae grown in red light and blue light which showed lesser growth rates than those under white light had higher percentage of enlarged cells. Enlarged cells of normal shape were successfully propagated for more than ten generations.

  13. Simple approximation for estimating centerline gamma absorbed dose rates due to a continuous Gaussian plume

    International Nuclear Information System (INIS)

    Overcamp, T.J.; Fjeld, R.A.

    1987-01-01

    A simple approximation for estimating the centerline gamma absorbed dose rates due to a continuous Gaussian plume was developed. To simplify the integration of the dose integral, this approach makes use of the Gaussian cloud concentration distribution. The solution is expressed in terms of the I1 and I2 integrals which were developed for estimating long-term dose due to a sector-averaged Gaussian plume. Estimates of tissue absorbed dose rates for the new approach and for the uniform cloud model were compared to numerical integration of the dose integral over a Gaussian plume distribution

  14. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  15. Granzyme B mediates both direct and indirect cleavage of extracellular matrix in skin after chronic low-dose ultraviolet light irradiation.

    Science.gov (United States)

    Parkinson, Leigh G; Toro, Ana; Zhao, Hongyan; Brown, Keddie; Tebbutt, Scott J; Granville, David J

    2015-02-01

    Extracellular matrix (ECM) degradation is a hallmark of many chronic inflammatory diseases that can lead to a loss of function, aging, and disease progression. Ultraviolet light (UV) irradiation from the sun is widely considered as the major cause of visible human skin aging, causing increased inflammation and enhanced ECM degradation. Granzyme B (GzmB), a serine protease that is expressed by a variety of cells, accumulates in the extracellular milieu during chronic inflammation and cleaves a number of ECM proteins. We hypothesized that GzmB contributes to ECM degradation in the skin after UV irradiation through both direct cleavage of ECM proteins and indirectly through the induction of other proteinases. Wild-type and GzmB-knockout mice were repeatedly exposed to minimal erythemal doses of solar-simulated UV irradiation for 20 weeks. GzmB expression was significantly increased in wild-type treated skin compared to nonirradiated controls, colocalizing to keratinocytes and to an increased mast cell population. GzmB deficiency significantly protected against the formation of wrinkles and the loss of dermal collagen density, which was related to the cleavage of decorin, an abundant proteoglycan involved in collagen fibrillogenesis and integrity. GzmB also cleaved fibronectin, and GzmB-mediated fibronectin fragments increased the expression of collagen-degrading matrix metalloproteinase-1 (MMP-1) in fibroblasts. Collectively, these findings indicate a significant role for GzmB in ECM degradation that may have implications in many age-related chronic inflammatory diseases. © 2014 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  16. TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Miles, D; Yoon, S [Duke University Medical Physics Graduate Program, Durham, NC (United States); Adamovics, J [Department of Chemistry and Biology, Rider University, Skillman, NJ (United States); Oldham, M [Duke University Medical Center, Durham, NC (United States)

    2016-06-15

    Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

  17. TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

    International Nuclear Information System (INIS)

    Miles, D; Yoon, S; Adamovics, J; Oldham, M

    2016-01-01

    Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

  18. Recovery of the proliferative and functional integrity of mouse bone marrow in long-term cultures established after whole-body irradiation at different doses and dose rates

    International Nuclear Information System (INIS)

    Bierkens, J.G.; Hendry, J.H.; Testa, N.G.

    1991-01-01

    Injury inflicted upon the bone marrow stroma following whole-body irradiation and its repair over a 1-year period has been assessed in murine long-term bone marrow cultures established at increasing time intervals after irradiation. Different doses at different dose rates (10 Gy at 0.05 cGy/min, 4.5 Gy and 10 Gy at 1.6 cGy/min, and 4 x 4.5 Gy [3 weeks between doses] at 60 cGy/min) were chosen so as to maximize differences in effect in the stroma. The cellularity of the adherent layer in long-term cultures established 1 month after irradiation was reduced by 40%-90% depending on the dose and dose rate. Simultaneous with the poor ability of the marrow to form adherent layers, the cumulative spleen colony-forming unit (CFU-S) and granulocyte-macrophage colony-forming cell (GM-CFC) production over a 7-week period was reduced to 0% and 30% of control cultures, respectively. The slow recovery of the adherent layer was paralleled by an increase in the numbers of CFU-S and GM-CFC in the supernatant. Cultures established from repeatedly irradiated mice performed poorly over the entire 1-year period. Whereas the regeneration of the stroma was near complete 1 year after irradiation, the CFU-S and GM-CFC levels reached only between 50% and 80% of control cultures, respectively. Also, the concentration of CFU-S and GM-CFC in the supernatant remained persistently lower in cultures established from irradiated mice as compared to control cultures. The levels of sulfated glycosaminoglycans, which have been implicated in the establishment of the functional integrity of the microenvironment, were not reduced in the adherent layers at any time after irradiation. These results indicate that the regeneration of the stroma is accompanied by an incomplete recovery of active hemopoiesis in vitro

  19. Half-dose non-contrast CT in the investigation of urolithiasis: image quality improvement with third-generation integrated circuit CT detectors.

    Science.gov (United States)

    Wang, Jun; Kang, Tony; Arepalli, Chesnal; Barrett, Sarah; O'Connell, Tim; Louis, Luck; Nicolaou, Savvakis; McLaughlin, Patrick

    2015-06-01

    The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p 0.05 for all comparisons). Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater at half-radiation dose indicating that the benefits of using novel IC detectors are greater in low and ultra-low-dose CT imaging.

  20. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  1. Recovery from damage induced by acridine plus near-ultraviolet light in Escherichia coli

    International Nuclear Information System (INIS)

    Wagner, S.; Feldman, A.; Snipes, W.

    1982-01-01

    Escherichia coli cells treated with sublethal doses of acridine plus near-UV light exhibit an effective split-dose recovery response that requires an incubation period of about 30-45 min. Studies of the metabolic requirements for split-dose recovery revealed the following: (a) DNA synthesis is not required for split-dose recovery: (b) inhibition of electron transport or protein synthesis reduces the efficiency of split-dose recovery by about one-half: (c) inhibition of phospholipid synthesis or cell wall synthesis completely eliminates the split-dose recovery response. These results suggest an involvement of membrane repair mechanisms in response to damage by acridine plus near-UV light. Additional evidence for such a process was provided by more direct assays for membrane recovery. It was found that cells treated with sublethal doses of acridine plus near-UV light are sensitive to low concentrations of detergents, and lose that sensitivity upon incubation. Likewise, treated cells are susceptible to lethal osmotic shock, but can recover from this susceptibility if incubated after treatment but prior to exposure to low osmotic conditions. Based on accumulating evidence it is proposed that E. coli cells are capable of repairing membrane damage resulting from exposure to acridine plus near-UV light. (author)

  2. Integrated boost IMRT with FET-PET-adapted local dose escalation in glioblastomas. Results of a prospective phase II study

    International Nuclear Information System (INIS)

    Piroth, M.D.; Pinkawa, M.; Holy, R.; Forschungszentrum Juelich GmbH

    2012-01-01

    Dose escalations above 60 Gy based on MRI have not led to prognostic benefits in glioblastoma patients yet. With positron emission tomography (PET) using [ 18 F]fluorethyl-L-tyrosine (FET), tumor coverage can be optimized with the option of regional dose escalation in the area of viable tumor tissue. In a prospective phase II study (January 2008 to December 2009), 22 patients (median age 55 years) received radiochemotherapy after surgery. The radiotherapy was performed as an MRI and FET-PET-based integrated-boost intensity-modulated radiotherapy (IMRT). The prescribed dose was 72 and 60 Gy (single dose 2.4 and 2.0 Gy, respectively) for the FET-PET- and MR-based PTV-FET (72 Gy) and PTV-MR (60 Gy) . FET-PET and MRI were performed routinely for follow-up. Quality of life and cognitive aspects were recorded by the EORTC-QLQ-C30/QLQ Brain20 and Mini-Mental Status Examination (MMSE), while the therapy-related toxicity was recorded using the CTC3.0 and RTOG scores. Median overall survival (OS) and disease-free survival (DFS) were 14.8 and 7.8 months, respectively. All local relapses were detected at least partly within the 95% dose volume of PTV-MR (60 Gy) . No relevant radiotherapy-related side effects were observed (excepted alopecia). In 2 patients, a pseudoprogression was observed in the MRI. Tumor progression could be excluded by FET-PET and was confirmed in further MRI and FET-PET imaging. No significant changes were observed in MMSE scores and in the EORTC QLQ-C30/QLQ-Brain20 questionnaires. Our dose escalation concept with a total dose of 72 Gy, based on FET-PET, did not lead to a survival benefit. Acute and late toxicity were not increased, compared with historical controls and published dose-escalation studies. (orig.)

  3. Integrated boost IMRT with FET-PET-adapted local dose escalation in glioblastomas. Results of a prospective phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Piroth, M.D.; Pinkawa, M.; Holy, R. [RWTH Aachen University Hospital (Germany). Dept. of Radiation Oncology; Forschungszentrum Juelich GmbH (DE). Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain] (and others)

    2012-04-15

    Dose escalations above 60 Gy based on MRI have not led to prognostic benefits in glioblastoma patients yet. With positron emission tomography (PET) using [{sup 18}F]fluorethyl-L-tyrosine (FET), tumor coverage can be optimized with the option of regional dose escalation in the area of viable tumor tissue. In a prospective phase II study (January 2008 to December 2009), 22 patients (median age 55 years) received radiochemotherapy after surgery. The radiotherapy was performed as an MRI and FET-PET-based integrated-boost intensity-modulated radiotherapy (IMRT). The prescribed dose was 72 and 60 Gy (single dose 2.4 and 2.0 Gy, respectively) for the FET-PET- and MR-based PTV-FET{sub (72 Gy)} and PTV-MR{sub (60 Gy)}. FET-PET and MRI were performed routinely for follow-up. Quality of life and cognitive aspects were recorded by the EORTC-QLQ-C30/QLQ Brain20 and Mini-Mental Status Examination (MMSE), while the therapy-related toxicity was recorded using the CTC3.0 and RTOG scores. Median overall survival (OS) and disease-free survival (DFS) were 14.8 and 7.8 months, respectively. All local relapses were detected at least partly within the 95% dose volume of PTV-MR{sub (60 Gy)}. No relevant radiotherapy-related side effects were observed (excepted alopecia). In 2 patients, a pseudoprogression was observed in the MRI. Tumor progression could be excluded by FET-PET and was confirmed in further MRI and FET-PET imaging. No significant changes were observed in MMSE scores and in the EORTC QLQ-C30/QLQ-Brain20 questionnaires. Our dose escalation concept with a total dose of 72 Gy, based on FET-PET, did not lead to a survival benefit. Acute and late toxicity were not increased, compared with historical controls and published dose-escalation studies. (orig.)

  4. New design of textile light diffusers for photodynamic therapy

    International Nuclear Information System (INIS)

    Cochrane, Cédric; Mordon, Serge R.; Lesage, Jean Claude; Koncar, Vladan

    2013-01-01

    A homogeneous and reproducible fluence delivery rate during clinical photodynamic therapy (PDT) plays a determinant role in preventing under- or overtreatment. PDT applied in dermatology has been carried out with a wide variety of light sources delivering a broad range of more or less adapted light doses. Due to the complexities of the human anatomy, these light sources do not in fact deliver a uniform light distribution to the skin. Therefore, the development of flexible light sources would considerably improve the homogeneity of light delivery. The integration of plastic optical fiber (POF) into textile structures could offer an interesting alternative. In this article, a textile light diffuser (TLD) has been developed using POF and Polyester yarns. Predetermined POF macrobending leads to side emission of light when the critical angle is exceeded. Therefore, a specific pattern based on different satin weaves has been developed in order to improve light emission homogeneity and to correct the decrease of side emitted radiation intensity along POF. The prototyped fabrics (approximately 100 cm 2 : 5 × 20 cm) were woven using a hand loom, then both ends of the POF were coupled to a laser diode (5 W, 635 nm). The fluence rate (mW/cm 2 ) and the homogeneity of light delivery by the TLD were evaluated. Temperature evolution, as a function of time, was controlled with an infrared thermographic camera. When using a power source of 5 W, the fluence rate of the TLD was 18 ± 2.5 mw/cm 2 . Due to the high efficiency of the TLD, the optical losses were very low. The TLD temperature elevation was 0.6 °C after 10 min of illumination. Our TLD meets the basic requirements for PDT: homogeneous light distribution and flexibility. It also proves that large (500 cm 2 ) textile light diffusers adapted to skin, but also to peritoneal or pleural cavity, PDTs can be easily produced by textile manufacturing processes

  5. The interaction between the light source dose and caspase-dependent and -independent apoptosis in human SK-MEL-3 skin cancer cells following photodynamic therapy with zinc phthalocyanine: A comparative study.

    Science.gov (United States)

    Doustvandi, Mohammad Amin; Mohammadnejad, Fateme; Mansoori, Behzad; Mohammadi, Ali; Navaeipour, Farzaneh; Baradaran, Behzad; Tajalli, Habib

    2017-11-01

    The aim of this study is to determine the behavior of relative expression of Bcl-2, caspase-8, caspase-9, and caspase-3 genes of/in SK-MEL-3 cancer cells and explore molecular mechanisms responsible for the apoptosis response during an in vitro photodynamic therapy (PDT) with Zinc Phthalocyanine (ZnPc) using different doses of the light source. In this study, firstly the cytotoxic effects of ZnPc-PDT on SK-MEL-3 cells were evaluated. By irradiating the laser, ZnPc induced a significant amount of apoptosis on SK-MEL-3 cells in three IC 50 s including 0.064±0.01, 0.043±0.01, and 0.036±0.01μg/mL at the doses of 8, 16, and 24J/cm 2 , respectively. Moreover, flow cytometry and QRT-PCR experiments were done. The high percentage of apoptotic cells was seen in the early apoptosis stage. The expression of Bcl-2 and caspase-8 genes at all doses of laser experienced an obvious reduction in comparison to the control group. On the other hand, although the expression of caspase-9 and caspase-3 genes remains almost constant at 8J/cm 2 , but they faced an increment at 16 and 24J/cm 2 doses. These data reveal caspase-dependent apoptosis in high and caspase-independent apoptosis in low doses of laser. Based on the results of present work, it can be suggested that the dose of the light source is a key factor in induction of caspase-dependent and caspase-independent apoptosis pathways following PDT. Copyright © 2017. Published by Elsevier B.V.

  6. Quantifying light pollution

    International Nuclear Information System (INIS)

    Cinzano, P.; Falchi, F.

    2014-01-01

    In this paper we review new available indicators useful to quantify and monitor light pollution, defined as the alteration of the natural quantity of light in the night environment due to introduction of manmade light. With the introduction of recent radiative transfer methods for the computation of light pollution propagation, several new indicators become available. These indicators represent a primary step in light pollution quantification, beyond the bare evaluation of the night sky brightness, which is an observational effect integrated along the line of sight and thus lacking the three-dimensional information. - Highlights: • We review new available indicators useful to quantify and monitor light pollution. • These indicators are a primary step in light pollution quantification. • These indicators allow to improve light pollution mapping from a 2D to a 3D grid. • These indicators allow carrying out a tomography of light pollution. • We show an application of this technique to an Italian region

  7. Low dose radiation effects: an integrative european approach (Risc-Rad Project) coordinated by the Cea

    International Nuclear Information System (INIS)

    Sabatier, L.

    2006-01-01

    RISC-RAD (Radiosensitivity of Individuals and Susceptibility to Cancer induced by ionizing Radiations) is an Integrated Project funded by the European Commission under 6. Framework Programme / EURATOM. RISC-RAD started on 1. January 2004 for a duration of four years. Coordinated by Cea (Dr Laure Sabatier), it involves 11 European countries (Austria, Denmark, Finland, France, Germany, Ireland, Italy, the Netherlands, Spain, Sweden and the United Kingdom) and 29 research institutions. Objectives: Exposures to low and protracted doses of ionizing radiation are very frequent in normal living environment, at work places, in industry and in medicine. Effects of these exposures on human health cannot be reliably assessed by epidemiological methods, nor is thoroughly understood by biologists. RISC-RAD project proposes to help bridging the gap of scientific knowledge about these effects. To achieve this goal, a necessary key step is to understand the basic mechanisms by which radiation induces cancer. Studying this multistage process in an integrated way, the project offers a new biological approach characterised by and clear-cut and objective-driven scientific policy: the project is focused on the effects of low doses (less than 100 mSv) and protracted doses of radiation. It aims at identifying new parameters that take into account the differences in radiation responses between individuals. A group of modelers works closely with the experimental teams in order to better quantify the risks associated with low and protracted doses. Research work is divided into five work packages interacting closely with each other. WP1 is dedicated to DNA damage. Ionizing Radiation (IR) produce a broad spectrum of base modifications and DNA strand breaks of different kinds, among which double-strand breaks and 'clustered damage' which is thought to be a major feature in biological effectiveness of IR. The aim of Work Package 1 is to improve understanding of the initial DNA damage induced by

  8. Recommendations to designers aimed at minimizing radiation dose incurred in operation, maintenance, inspection and repair of light-water reactors

    International Nuclear Information System (INIS)

    1978-01-01

    In the framework of the exchange of experience between nuclear power plant operators organized by the services of the Commission of the European Communities an ad-hoc working party elaborated recommendations particularly directed to those concerned with design of light water reactor plants. The necessary design measures which should be followed to minimize radiation dose incurred in operation, maintenance, inspection and repair of such reactors are listed. The recommendations are based on recent views expressed by operating utilities within the Community. It is intended to revise these recommendations at suitable intervals in order to make use of the most recent experience and to keep the report up to date with the actual state of art in nuclear technology

  9. Kinetic and dose dependences of the SOS-induction in E.coli K-12 (uvrA) cells exposed to the different UV doses

    International Nuclear Information System (INIS)

    Komova, O.V.; Kandiano, E.S.; Malavya, G.

    1999-01-01

    The kinetic and dose dependences of the SOS-induction in E.coli (uvrA) cells exposed to UV light were investigated. Below 2 J/m 2 the rate of the SOS-induction increased with dose. The maximal level of the SOS-response was proportional to the UV dose. Pyrimidine dimers were necessary for the induction. In the dose range 2-10 J/m 2 the rate of the SOS-induction decreased with dose. The dose-response curve was non-linear. Pyrimidine dimers were not required for the induction. The nature of the molecular events leading to the SOS-induction at low and high UV doses was discussed. (author)

  10. Dose response of hydrazine - Deproteinated tooth enamel under blue light stimulation

    International Nuclear Information System (INIS)

    Yuece, Ulkue Rabia; Meric, Niyazi; Atakol, Orhan; Yasar, Fusun

    2010-01-01

    The beta dose response and Optically Stimulated Luminescence (OSL) signal stability characteristics of human tooth enamel deproteinated by hydrazine reagent under blue photon stimulation are reported. Removal of the protein organic component of tooth enamel resulted in a higher OSL sensitivity and slower fading of OSL signals. The effect of chemical sample preparation on the enamel sample sensitivity is discussed and further steps to make this deproteinization treatment suitable for in vitro dose reconstruction studies are suggested.

  11. Dose response of hydrazine - Deproteinated tooth enamel under blue light stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Yuece, Ulkue Rabia, E-mail: ulkuyuce@hotmail.co [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Tandogan - Ankara (Turkey); Meric, Niyazi, E-mail: meric@ankara.edu.t [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Tandogan - Ankara (Turkey); Atakol, Orhan, E-mail: atakol@science.ankara.edu.t [Ankara University, Science Faculty, Department of Chemistry, 06100, Tandogan - Ankara (Turkey); Yasar, Fusun, E-mail: ab121310@adalet.gov.t [Council of Forensic Medicine, Ankara Branch, Ankara (Turkey)

    2010-08-15

    The beta dose response and Optically Stimulated Luminescence (OSL) signal stability characteristics of human tooth enamel deproteinated by hydrazine reagent under blue photon stimulation are reported. Removal of the protein organic component of tooth enamel resulted in a higher OSL sensitivity and slower fading of OSL signals. The effect of chemical sample preparation on the enamel sample sensitivity is discussed and further steps to make this deproteinization treatment suitable for in vitro dose reconstruction studies are suggested.

  12. Direct Energy Centre underground parking integrated light control system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-10-15

    LightSavers is a project undertaken by the Toronto Atmospheric Fund to accelerate the use of lighting technologies. As part of the project a pilot test has been carried out in the Direct Energy Center in Toronto. The aim of this report is to present the study and its results. The Direct Energy Center is a large event facility with an large underground parking facility. A lighting energy management system, the energy control system (ECS), capable of adjusting lighting levels based on occupancy was implemented in the centre and data was collected during over one year. Results showed that the ECS permitted a reduction in energy consumption and thus greenhouse gas emissions by 47% and the payback will take less than 6 years. This project demonstrated that the energy control system provides better energy, environmental and economic performance than a traditional automation system.

  13. Device for simulation of integral dose distribution in multifield radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, E K; Voronin, V V; Kolosova, V F; Moskalev, A I; Marova, Yu M; Stavitskii, R V; Yarovoi, V S

    1974-11-15

    Described is a device for simulation of the sum dose distribution at multifield radiation therapy; the device comprises a mechanical unit on which the emission sources and detectors are mounted, an electromechanical scanning equipment, amplifiers, an adder, a position sensor and a recording instrument. The device suggested raises an accuracy of a sick man radiation program elaboration at a remote multifield radiation therapy, permits to estimate the irradiated medium heterogeneity and beam shaper influence on the sum dose distribution and also ensured the information on the sum dose distribution of the relative or absolute units. Additional filters simulating heterogeneity and beam shaping conditions of ionizing radiation may be mounted between the quantum emission sources and detectors, and an amplifier with a variable amplification factor may be placed between the adders and printers. Thus it is possible to obtain a sum dose distribution at static methods of the remote radiation therapy at a high degree of accuracy (up to +-10%).

  14. The Experience of Dynamic Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Kristensen, Ole

    2017-01-01

    of daylight openings and the experience of spatial form. However, current developments in LED light sources (light emitting diodes) and adaptive software control systems allow for an enhanced correlation between daylight and artificial lighting, where the variations of the daylight are dynamically...... supplemented by variations in the artificial lighting. The suggestion is to develop a particular type of Observational Instrument that situates detailed experiential investigations into the design potentials of integration of natural and artificial lighting, and thereby to enable differentiated dynamic...

  15. Task related doses in spanish light water reactors over the period 1990-1996

    International Nuclear Information System (INIS)

    Aroca, J.; Montesinos, J.J.; O'Donnell, P.; Amor, I.; Butragueno, J.L.

    1998-01-01

    In order to evaluate in depth the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities -7 PWR (6 Westinghouse and 1 KWU-Siemens) and 2 BWR (Generic Electric), and to have a further overview of dose trends, the CSN has analysed the task related doses data over the period 1990-1996. The scope of this analysis includes the collective dose and relative relevance for 18 different refuelling outage tasks, some sub-tasks, 12 department staff, and the main consolidated dose reduction-techniques and good practices. Data has been collected from the outage reports NPPs provide according to the CSN 1.5 Safety Guide format. (Author)

  16. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  17. Continuous-Integration Laser Energy Lidar Monitor

    Science.gov (United States)

    Karsh, Jeremy

    2011-01-01

    This circuit design implements an integrator intended to allow digitization of the energy output of a pulsed laser, or the energy of a received pulse of laser light. It integrates the output of a detector upon which the laser light is incident. The integration is performed constantly, either by means of an active integrator, or by passive components.

  18. Passive technologies for future large-scale photonic integrated circuits on silicon: polarization handling, light non-reciprocity and loss reduction

    Directory of Open Access Journals (Sweden)

    Daoxin Dai

    2012-03-01

    Full Text Available Silicon-based large-scale photonic integrated circuits are becoming important, due to the need for higher complexity and lower cost for optical transmitters, receivers and optical buffers. In this paper, passive technologies for large-scale photonic integrated circuits are described, including polarization handling, light non-reciprocity and loss reduction. The design rule for polarization beam splitters based on asymmetrical directional couplers is summarized and several novel designs for ultra-short polarization beam splitters are reviewed. A novel concept for realizing a polarization splitter–rotator is presented with a very simple fabrication process. Realization of silicon-based light non-reciprocity devices (e.g., optical isolator, which is very important for transmitters to avoid sensitivity to reflections, is also demonstrated with the help of magneto-optical material by the bonding technology. Low-loss waveguides are another important technology for large-scale photonic integrated circuits. Ultra-low loss optical waveguides are achieved by designing a Si3N4 core with a very high aspect ratio. The loss is reduced further to <0.1 dB m−1 with an improved fabrication process incorporating a high-quality thermal oxide upper cladding by means of wafer bonding. With the developed ultra-low loss Si3N4 optical waveguides, some devices are also demonstrated, including ultra-high-Q ring resonators, low-loss arrayed-waveguide grating (demultiplexers, and high-extinction-ratio polarizers.

  19. Transition of some type of integrated circuits into latch-up mode under effect of ionizing radiation of large dose rate

    International Nuclear Information System (INIS)

    Berdichevskij, B.E.; Madzharova, T.B.

    1986-01-01

    Some types of integrated circuits (IC) are almost short-circuit, i.e. they transit to the latch-up regime under the effect of ionizing radiation pulses of large dose rate. The results of investigation into IC under their transition into the latch-up regime at supply voltage of 10 V are presented. It is shown that IC stably transit to the latch-up regime if the dinistor current becomes at least equal to the photocurrent. At bias reduction from 15 to 6 V the dose rate at which the latch-up arises grows from 2.5x10 9 to 3.5x10 9 rad (Si)/s. Burn-out of supply busbar is the usual type of IC failure at latch-up arising. Measures for IC protection from latch-up are shown. In some IC the latch-up is formed beginning from a certain critical value of dose rate, the so-called ''windows'' of latch-up

  20. Light Robotics and its potential for integrating with magnetic carriers

    DEFF Research Database (Denmark)

    Glückstad, Jesper

    . After years of working on light-driven trapping and manipulation, we can see that a confluence of developments is now ripe for the emergence of a new area that can contribute to nanobiophotonics – Light Robotics – which combines advances in microfabrication and optical micromanipulation together...... with intelligent control ideas from robotics, wavefront engineering and computational optics. In the Summer 2017 we published a ca. 500 pages edited Elsevier book volume covering the fundamental aspects needed for Light Robotics including optical trapping systems, microfabrication and microassembly as well...... as underlying theoretical principles and experimental illustrations for optimizing optical forces and torques for Light Robotics. The Elsevier volume is presenting various new functionalities that are enabled by these new designed light-driven micro-robots in addition to various nano-biophotonics applications...

  1. Optimized probes for dose rate measurements at local government sites and in emergency planning zones and their integration into measurement networks

    International Nuclear Information System (INIS)

    Kuca, Petr; Helebrant, Jan; Cespirova, Irena; Judas, Libor; Skala, Lukas

    2015-01-01

    The results of a security project aimed at the development of a radiation situation monitoring system using optimized probes for dose rate measurements are described. The system is suitable for use at local government sites as well as at other sites. The system includes dose rate measurement probes with the variable configuration functionality (detection part), equipment for data transfer to a central workplace (communication part) and application for collection, storage and administration of the results and their presentation at a website (presentation part). The dosimetric and other operational properties of the probes were tested and the feasibility of their integration into measurement networks using the IMS central application was examined. (orig.)

  2. Treatment planning and dose analysis for interstitial photodynamic therapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Sean R H; Gertner, Mark R; Bogaards, Arjen; Sherar, Michael D; Wilson, Brian C [Division of Biophysics and Bioimaging, Ontario Cancer Institute, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Weersink, Robert A; Giewercer, David [Laboratory for Applied Biophysics, Ontario Cancer Institute, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A [Joint Department of Medical Imaging, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Scherz, Avigdor [Department of Plant Science, Weizmann Institute of Science, PO Box 26, Rehovot 76100 (Israel); Elhilali, Mostafa [Department of Surgery, McGill University, 3655 Promenade Sir William Osler, Montreal, Quebec H3G 1Y6 (Canada); Chin, Joseph L [Department of Oncology, University of Western Ontario, 800 Commissioners Road East, PO Box 5010, London, Ontario N6A 5W9 (Canada); Trachtenberg, John [Department of Urology, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada)], E-mail: wilson@uhnres.utoronto.ca

    2009-04-21

    With the development of new photosensitizers that are activated by light at longer wavelengths, interstitial photodynamic therapy (PDT) is emerging as a feasible alternative for the treatment of larger volumes of tissue. Described here is the application of PDT treatment planning software developed by our group to ensure complete coverage of larger, geometrically complex target volumes such as the prostate. In a phase II clinical trial of TOOKAD vascular targeted photodynamic therapy (VTP) for prostate cancer in patients who failed prior radiotherapy, the software was used to generate patient-specific treatment prescriptions for the number of treatment fibres, their lengths, their positions and the energy each delivered. The core of the software is a finite element solution to the light diffusion equation. Validation against in vivo light measurements indicated that the software could predict the location of an iso-fluence contour to within approximately {+-}2 mm. The same software was used to reconstruct the treatments that were actually delivered, thereby providing an analysis of the threshold light dose required for TOOKAD-VTP of the post-irradiated prostate. The threshold light dose for VTP-induced prostate damage, as measured one week post-treatment using contrast-enhanced MRI, was found to be highly heterogeneous, both within and between patients. The minimum light dose received by 90% of the prostate, D{sub 90}, was determined from each patient's dose-volume histogram and compared to six-month sextant biopsy results. No patient with a D{sub 90} less than 23 J cm{sup -2} had complete biopsy response, while 8/13 (62%) of patients with a D{sub 90} greater than 23 J cm{sup -2} had negative biopsies at six months. The doses received by the urethra and the rectal wall were also investigated.

  3. Methods, safety, and early clinical outcomes of dose escalation using simultaneous integrated and sequential boosts in patients with locally advanced gynecologic malignancies.

    Science.gov (United States)

    Boyle, John; Craciunescu, Oana; Steffey, Beverly; Cai, Jing; Chino, Junzo

    2014-11-01

    To evaluate the safety of dose escalated radiotherapy using a simultaneous integrated boost technique in patients with locally advanced gynecological malignancies. Thirty-nine women with locally advanced gynecological malignancies were treated with intensity modulated radiation therapy utilizing a simultaneous integrated boost (SIB) technique for gross disease in the para-aortic and/or pelvic nodal basins, sidewall extension, or residual primary disease. Women were treated to 45Gy in 1.8Gy fractions to elective nodal regions. Gross disease was simultaneously treated to 55Gy in 2.2Gy fractions (n=44 sites). An additional sequential boost of 10Gy in 2Gy fractions was delivered if deemed appropriate (n=29 sites). Acute and late toxicity, local control in the treated volumes (LC), overall survival (OS), and distant metastases (DM) were assessed. All were treated with a SIB to a dose of 55Gy. Twenty-four patients were subsequently treated with a sequential boost to a median dose of 65Gy. Median follow-up was 18months. Rates of acute>grade 2 gastrointestinal (GI), genitourinary (GU), and hematologic (heme) toxicities were 2.5%, 0%, and 30%, respectively. There were no grade 4 acute toxicities. At one year, grade 1-2 late GI toxicities were 24.5%. There were no grade 3 or 4 late GI toxicities. Rates of grade 1-2 late GU toxicities were 12.7%. There were no grade 3 or 4 late GU toxicities. Dose escalated radiotherapy using a SIB results in acceptable rates of acute toxicity. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Visual indicator of absorbed radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Generalova, V V; Krasovitskii, B M; Vainshtok, B A; Gurskii, M N

    1968-10-15

    A visual indicator of the absorbed doses of ionizing radiation is proposed. The indicator has a polymer base with the addition of a dye. A distinctive feature of the indicator consists of the use of polystyrene as its polymer base with the addition of halogen-containing hydrocarbon and the light-proof dye. Such combination of the radiation-resistant polymer of polystyrene and the light-proof dyestuff makes the proposed indicator highly stable.

  5. Long-term reversibility of renal dysfunction associated to light chain deposition disease with bortezomib and dexamethasone and high dose therapy and autologous stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Tomás J. González-López

    2011-11-01

    Full Text Available A 63-year-old woman presented with progressive renal insufficiency, until a glomerular filtration rate (GFR of 12 mL/min. A renal biopsy demonstrated glomerular deposition of immunoglobulin k light chain. The presence of a small population of monoclonal plasmacytes producing an only light k monoclonal component was demonstrated and Bortezomib and Dexamethasone (BD was provided as initial therapy. After seven courses of therapy, renal function improved without dialysis requirements up to a GFR 31 mL/min. Under hematological complete response (HCR the patient underwent high dose of melphalan (HDM and autologous peripheral blood stem cell transplant. Fifty-four months later the patient remains in HCR and the GFR has progressively improved up to 48 mL/min. This report describes a notably renal function improvement in a patient with Light Chain Deposition Disease after therapy with BD followed by HDM, which can support this treatment as a future option for these patients.

  6. Dose reduction at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Dionne, B.J.

    1983-01-01

    The collective dose equivalent at nuclear power plants increased from 1250 rem in 1969 to nearly 54,000 rem in 1980. This rise is attributable primarily to an increase in nuclear generated power from 1289 MW-y to 29,155 MW-y; and secondly, to increased average plant age. However, considerable variation in exposure occurs from plant to plant depending on plant type, refueling, maintenance, etc. In order to understand the factors influencing these differences, an investigation was initiated to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at light water plants. Objectives are to: identify high-dose maintenance tasks and related dose-reduction techniques; investigate utilization of high-reliability, low-maintenance equipment; recommend improved radioactive waste handling equipment and procedures; examine incentives for dose reduction; and compile an ALARA handbook

  7. Influence of environmental factors on some high dose dosimeter responses in Yazd Radiation Processing Center

    International Nuclear Information System (INIS)

    Ziaie, F.; Tahami, S.M.; Zareshahi, H.; Lanjanian, H.; Durrani, S.A.

    2008-01-01

    In this paper attempt has been made to study the influence of temperature and UV light (exist in laboratory due to the fluorescent light or diffused sunlight) on some high dose dosimetry responses that are being used in Yazd Radiation Processing Center (YRPC). The CTA, FWT and B3 film dosimeters were used for this investigation. The correction of the read response of the dosimeters to the real absorbed dose values is very important especially while we need to measure the precise dose values in the medical devices and in foodstuff materials. Yazd city is near to the desert, and so temperature and UV light due to the sun are very different in compare to other cities. Therefore, we tried to investigate the temperature and UV light effects on the dosimeter response in different doses and obtain its variation as a function of temperature (up to ∼60 0 C) and exposure time (up to ∼1 year), respectively

  8. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  9. How to Frame Universal Workspace Lighting

    DEFF Research Database (Denmark)

    Mathiasen, Nanet; Frandsen, Anne Kathrine

    2016-01-01

    ; regardless of disability everybody should be able to move around in the house and work in any of the offices. One, of many ambitions, was to design a functional and effective lighting scheme using as much daylight as possible, and integrating the artificial lighting design and daylight design. The lighting...

  10. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  11. Integrating visible light 3D scanning into the everyday world

    Science.gov (United States)

    Straub, Jeremy

    2015-05-01

    Visible light 3D scanning offers the potential to non-invasively and nearly non-perceptibly incorporate 3D imaging into the everyday world. This paper considers the various possible uses of visible light 3D scanning technology. It discusses multiple possible usage scenarios including in hospitals, security perimeter settings and retail environments. The paper presents a framework for assessing the efficacy of visible light 3D scanning for a given application (and compares this to other scanning approaches such as those using blue light or lasers). It also discusses ethical and legal considerations relevant to real-world use and concludes by presenting a decision making framework.

  12. Characteristics Of Dosimeter TL CaSO4:Dy Glass Capillaries For Environmental Radiation Dose Monitoring

    International Nuclear Information System (INIS)

    Sofyan Hasnel; Yulianti, Helfi; Ramain, Abubakar; Kusumawati, Dyah D.; Suyati

    2000-01-01

    research on the characteristic of dosimeter TL CaSO 4 : Dy glass capillaries for environmental dose radiation have been carried out. The results obtained are uniform response and reproducibility during three cycles consumption with average percentage standard deviation of 7.31 % and 5.45%. The response dose is linear and has a minimum detectable dose of 0.01 mGy, sunshine effect with non-penetrating light capsule of 4.65%, humidity effects is not significant by using non-penetrating light capsule. Radiation dose information during 30 days are fading 25%

  13. Structurally Integrated Photoluminescence-Based Lactate Sensor Using Organic Light Emitting Devices (OLEDs) as the Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Chengliang [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    Multianalyte bio(chemical) sensors are extensively researched for monitoring analytes in complex systems, such as blood serum. As a step towards developing such multianalyte sensors, we studied a novel, structurally integrated, organic light emitting device (OLED)-based sensing platform for detection of lactate. Lactate biosensors have attracted numerous research efforts, due to their wide applications in clinical diagnosis, athletic training and food industry. The OLED-based sensor is based on monitoring the oxidation reaction of lactate, which is catalyzed by the lactate oxidase (LOX) enzyme. The sensing component is based on an oxygen-sensitive dye, Platinum octaethyl porphyrin (PtOEP), whose photoluminescence (PL) lifetime τ decreases as the oxygen level increases. The PtOEP dye was embedded in a thin film polystyrene (PS) matrix; the LOX was dissolved in solution or immobilized in a sol-gel matrix. τ was measured as a function of the lactate concentration; as the lactate concentration increases, τ increases due to increased oxygen consumption. The sensors performance is discussed in terms of the detection sensitivity, dynamic range, and response time. A response time of ~32 sec was achieved when the LOX was dissolved in solution and kept in a closed cell. Steps towards development of a multianalyte sensor array using an array of individually addressable OLED pixels were also presented.

  14. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  15. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  16. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    Science.gov (United States)

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  17. Personalized Risk Assessment in Never, Light, and Heavy Smokers in a prospective cohort in Taiwan.

    Science.gov (United States)

    Wu, Xifeng; Wen, Chi Pang; Ye, Yuanqing; Tsai, MinKwang; Wen, Christopher; Roth, Jack A; Pu, Xia; Chow, Wong-Ho; Huff, Chad; Cunningham, Sonia; Huang, Maosheng; Wu, Shuanbei; Tsao, Chwen Keng; Gu, Jian; Lippman, Scott M

    2016-11-02

    The objective of this study was to develop markedly improved risk prediction models for lung cancer using a prospective cohort of 395,875 participants in Taiwan. Discriminatory accuracy was measured by generation of receiver operator curves and estimation of area under the curve (AUC). In multivariate Cox regression analysis, age, gender, smoking pack-years, family history of lung cancer, personal cancer history, BMI, lung function test, and serum biomarkers such as carcinoembryonic antigen (CEA), bilirubin, alpha fetoprotein (AFP), and c-reactive protein (CRP) were identified and included in an integrative risk prediction model. The AUC in overall population was 0.851 (95% CI = 0.840-0.862), with never smokers 0.806 (95% CI = 0.790-0.819), light smokers 0.847 (95% CI = 0.824-0.871), and heavy smokers 0.732 (95% CI = 0.708-0.752). By integrating risk factors such as family history of lung cancer, CEA and AFP for light smokers, and lung function test (Maximum Mid-Expiratory Flow, MMEF 25-75% ), AFP and CEA for never smokers, light and never smokers with cancer risks as high as those within heavy smokers could be identified. The risk model for heavy smokers can allow us to stratify heavy smokers into subgroups with distinct risks, which, if applied to low-dose computed tomography (LDCT) screening, may greatly reduce false positives.

  18. Light Regulation of Swarming Motility in Pseudomonas syringae Integrates Signaling Pathways Mediated by a Bacteriophytochrome and a LOV Protein

    Science.gov (United States)

    Wu, Liang; McGrane, Regina S.; Beattie, Gwyn A.

    2013-01-01

    ABSTRACT The biological and regulatory roles of photosensory proteins are poorly understood for nonphotosynthetic bacteria. The foliar bacterial pathogen Pseudomonas syringae has three photosensory protein-encoding genes that are predicted to encode the blue-light-sensing LOV (light, oxygen, or voltage) histidine kinase (LOV-HK) and two red/far-red-light-sensing bacteriophytochromes, BphP1 and BphP2. We provide evidence that LOV-HK and BphP1 form an integrated network that regulates swarming motility in response to multiple light wavelengths. The swarming motility of P. syringae B728a deletion mutants indicated that LOV-HK positively regulates swarming motility in response to blue light and BphP1 negatively regulates swarming motility in response to red and far-red light. BphP2 does not detectably regulate swarming motility. The histidine kinase activity of each LOV-HK and BphP1 is required for this regulation based on the loss of complementation upon mutation of residues key to their kinase activity. Surprisingly, mutants lacking both lov and bphP1 were similar in motility to a bphP1 single mutant in blue light, indicating that the loss of bphP1 is epistatic to the loss of lov and also that BphP1 unexpectedly responds to blue light. Moreover, whereas expression of bphP1 did not alter motility under blue light in a bphP1 mutant, it reduced motility in a mutant lacking lov and bphP1, demonstrating that LOV-HK positively regulates motility by suppressing negative regulation by BphP1. These results are the first to show cross talk between the LOV protein and phytochrome signaling pathways in bacteria, and the similarity of this regulatory network to that of photoreceptors in plants suggests a possible common ancestry. PMID:23760465

  19. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  20. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the

  1. Urban contamination and dose model

    International Nuclear Information System (INIS)

    Robertson, E.; Barry, P.J.

    1995-10-01

    Nuclear power reactors and other nuclear facilities are being built near or even within urban centres. Accidental releases of radionuclides to the atmosphere in built-up areas result in radiological exposure pathways that differ from those caused by releases in rural environments. Other than inhalation, exposure pathways involve external radiation from the plume while it passes and from radioactivity deposited onto the many and varied surfaces after it has passed. Radiation fields inside buildings are attenuated but many people are potentially exposed so while individual doses may be relatively low, population integrated doses may be high enough to cause concern. It is important, therefore, to assess the potential exposures and to estimate the cost-effectiveness of dose reduction measures in urban environments. This report describes a model developed to carry out such assessments. The model draws heavily on experience gained in European cities after their contamination fallout from the Chernobyl accident. Input is time integrated concentrations of specific radionuclides in urban air, obtained either by direct measurement or by prediction using an atmospheric dispersion model. The code includes default values for site specific variables and transfer parameters but the user is invited if desired to enter other values from the keyboard. Output is the time integrated dose rates for individuals selected because of the characteristic living, working and recreational habits. An accompanying manual documents the technical background on which the model is based and leads a first-time suer through various steps and operations encountered while the model is running. (author). 60 refs., 10 tabs., 1 fig

  2. Lightness constancy: Object identity and temporal integration

    Directory of Open Access Journals (Sweden)

    Zdravković Sunčica

    2008-01-01

    Full Text Available Studies of lightness constancy typically involve the comparison of two objects of the same shade that have been placed under different illuminations. In this study, we introduce factors such as object identity and immediate prior experience to measure the effect of these manipulations on constancy. In the first experiment, conditions sufficient to reproduce classical constancy failure (illumination difference, target values, articulation level were determined. In the second experiment a lightness judgment was made for a gray target that was then seen to move into another illumination level for the second match. Motion was used in an attempt to stress the target’s identity. The shade was still judged significantly lighter when placed under the higher than under the lower illumination. Failure of constancy thus occurred even when object identity was not in question. In the third experiment a priming paradigm was used, to assess the strength of constancy: one shade would appear in one illumination level and another shade in the other illumination level. Motion was used to trick observers into thinking that only a single object was presented. The estimated shade varied as a function of the shade of the prime. In the last experiment, observers were asked to make another match when the object was removed from view: the match of its true color independent of illumination. The value of this match-from-memory was based on the value obtained in the higher illumination level. Taken together, the experiments show that through object identity, immediate prior experience can influence lightness in systematic fashion.

  3. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning

    International Nuclear Information System (INIS)

    Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon

    2003-01-01

    Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely

  4. Light-by-light-type corrections to the muon anomalous magnetic moment at four-loop order

    International Nuclear Information System (INIS)

    Kurz, Alexander; Smirnov, Alexander V.; Smirnov, Vladimir A.

    2015-08-01

    The numerically dominant QED contributions to the anomalous magnetic moment of the muon stem from Feynman diagrams with internal electron loops. We consider such corrections and present a calculation of the four-loop light-by-light-type corrections where the external photon couples to a closed electron or muon loop. We perform an asymptotic expansion in the ratio of electron and muon mass and reduce the resulting integrals to master integrals which we evaluate using analytical and numerical methods. We confirm the results present in the literature which are based on different computational methods.

  5. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  6. Dual-peak dose measurement for radiochromic films by a newly developed spectral microdensitometer

    International Nuclear Information System (INIS)

    Lee, K.Y.; Fung, K.K.L.; Kwok, C.S.

    2005-01-01

    Radiochromic film (RCF) dosimetry is usually based on densitometric methods which use an analyzing light source of a fixed or a broad spectrum of wavelengths. These methods have not exploited the sensitivity of the dose response of the RCF otherwise attainable by using a light source with wavelengths peaked at the two absorption peaks in the absorption spectrum of the RCF. A new algorithm of dual-peak dose measurement for the RCF has been proposed in this paper to make use of these dual absorption peaks to achieve the maximum attainable sensitivity. This technique relies on the measurement of the transmittance of the RCF at the wavelength of the major and minor absorption peaks, respectively. The dual-peak dose measurement is accomplished with the aid of a novel spectral microdensitometer developed in our Institute. The microdensitometer utilizes a monochromator to provide a light source of which the wavelength can be matched precisely to the wavelength of the absorption peaks of the RCF. The doses obtained at these wavelengths are fed into a weighted objective function and an optimum dose is searched by minimizing the objective function to give the best estimate of the dose deposited on the film. An initial test shows that there is a good agreement between the estimated and actual dose deposited; and the maximum discrepancy was found to be less than 1%

  7. III-nitride Photonic Integrated Circuit: Multi-section GaN Laser Diodes for Smart Lighting and Visible Light Communication

    KAUST Repository

    Shen, Chao

    2017-01-01

    The past decade witnessed the rapid development of III-nitride light-emitting diodes (LEDs) and laser diodes (LDs), for smart lighting, visible-light communication (VLC), optical storage, and internet-of-things. Recent studies suggested that the Ga

  8. Integrated effects of reduction dose of nitrogen fertilizer and mode of biofertilizer application on soil health under mung bean cropping system

    Directory of Open Access Journals (Sweden)

    Naba Kumar Mondal

    2014-12-01

    Full Text Available To study the integrated effects of reduced dose of chemical fertilizer with different methods and times of application of Rhizobium biofertilizer on soil health and fertility under mung bean (Vigna radiata cropping, field experiments were carried out during three years (2009, 2010, and 2011 in West Bengal, India, in randomized block design. In the first year, varietal screening of mung bean under recommended dose of chemical fertilizer (20:40:20 were performed with five available varieties adapted to local climate. Reduced nitrogen fertilizer doses (20%, 30%, 40%, 50%, and 60% and the recommended dose, as well as the Rhizobium biofertilizer application (basal, soil, and spray, were done, and data were recorded for pH, electrical conductivity, organic carbon, total nitrogen, total phosphorus, total potassium, and bacterial population of soil, both before sowing and after harvesting. The results indicated significant improvement in the soil quality with gradual buildup of soil macronutrient status after harvesting of crop. Application of biofertilizer has contributed significantly towards higher soil organic matter, nitrogen, phosphorus, and potassium. The use of biofertilizer significantly improved soil bacterial population count in the soil thereby increasing the soil health.

  9. A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery

    International Nuclear Information System (INIS)

    Tyagi, Neelam; Yang Kai; Gersten, David; Yan Di

    2012-01-01

    Purpose: To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. Methods: The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the linac in clinical mode and records, displays, and compares real time machine parameters with the planned parameters. A new measure, called integral error, keeps a running total of leaf overshoot and undershoot errors in each leaf pair, multiplied by leaf width, and the amount of time during which the error exists in monitor unit delivery. Another tool reconstructs Pinnacle 3 ™ format delivered plan based on the saved machine logfile and recalculates actual delivered dose in patient anatomy. Delivery characteristics of various standard fractionation and stereotactic body radiation therapy (SBRT) VMAT plans delivered on Elekta Axesse and Synergy linacs were quantified. Results: The MLC and gantry errors for all the treatment sites were 0.00 ± 0.59 mm and 0.05 ± 0.31°, indicating a good MLC gain calibration. Standard fractionation plans had a larger gantry error than SBRT plans due to frequent dose rate changes. On average, the MLC errors were negligible but larger errors of up to 6 mm and 2.5° were seen when dose rate varied frequently. Large gantry errors occurred during the acceleration and deceleration process, and correlated well with MLC errors (r= 0.858, p= 0.0004). PTV mean, minimum, and maximum dose discrepancies were 0.87 ± 0.21%, 0.99 ± 0.59%, and 1.18 ± 0.52%, respectively. The organs at risk (OAR) doses were within 2.5%, except some OARs that showed up to 5.6% discrepancy in maximum dose. Real time displayed normalized total positive integral error (normalized to the total monitor units) correlated linearly with MLC (r= 0.9279, p < 0.001) and gantry errors (r= 0.742, p= 0.005). There is a strong correlation between total integral

  10. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  11. Dose calculation in eye brachytherapy with Ir-192 threads using the Sievert integral and corrected by attenuation and scattering with the Meisberg polynomials

    International Nuclear Information System (INIS)

    Vivanco, M.G. Bernui de; Cardenas R, A.

    2006-01-01

    The ocular brachytherapy many times unique alternative to conserve the visual organ in patients of ocular cancer, one comes carrying out in the National Institute of Neoplastic Illnesses (INEN) using threads of Iridium 192; those which, they are placed in radial form on the interior surface of a spherical cap of gold of 18 K; the cap remains in the eye until reaching the prescribed dose by the doctor. The main objective of this work is to be able to calculate in a correct and practical way the one time that the treatment of ocular brachytherapy should last to reach the dose prescribed by the doctor. To reach this objective I use the Sievert integral corrected by attenuation effects and scattering (Meisberg polynomials); calculating it by the Simpson method. In the calculations by means of the Sievert integral doesn't take into account the scattering produced by the gold cap neither the variation of the constant of frequency of exposure with the distance. The calculations by means of Sievert integral are compared with those obtained using the Monte Carlo Penelope simulation code, where it is observed that they agree at distances of the surface of the cap greater or equal to 2mm. (Author)

  12. Visible light reduces C. elegans longevity.

    Science.gov (United States)

    De Magalhaes Filho, C Daniel; Henriquez, Brian; Seah, Nicole E; Evans, Ronald M; Lapierre, Louis R; Dillin, Andrew

    2018-03-02

    The transparent nematode Caenorhabditis elegans can sense UV and blue-violet light to alter behavior. Because high-dose UV and blue-violet light are not a common feature outside of the laboratory setting, we asked what role, if any, could low-intensity visible light play in C. elegans physiology and longevity. Here, we show that C. elegans lifespan is inversely correlated to the time worms were exposed to visible light. While circadian control, lite-1 and tax-2 do not contribute to the lifespan reduction, we demonstrate that visible light creates photooxidative stress along with a general unfolded-protein response that decreases the lifespan. Finally, we find that long-lived mutants are more resistant to light stress, as well as wild-type worms supplemented pharmacologically with antioxidants. This study reveals that transparent nematodes are sensitive to visible light radiation and highlights the need to standardize methods for controlling the unrecognized biased effect of light during lifespan studies in laboratory conditions.

  13. A new integrating sphere design for spectral radiant flux determination of light-emitting diodes

    Science.gov (United States)

    Hanselaer, P.; Keppens, A.; Forment, S.; Ryckaert, W. R.; Deconinck, G.

    2009-09-01

    Light-emitting diode (LED) technology is developing very quickly and may be considered an alternative for traditional light sources. However, at this moment, manufacturers and end users of LEDs are facing a rather basic but major problem. The lack of standardization regarding optical and electrical characterization of LEDs appears to compromise a successful implementation. In particular, numbers quoted for the luminous flux, and consequently for the efficacy of LEDs, are very sensitive data because they are used to impress and push the LED market. In this paper, the most was made of the typical hemispherical radiation of high-power LEDs to increase the accuracy of the flux determination using a custom-made integrating sphere. Recently developed measurement techniques such as the use of an external spectral irradiance standard and an optimized spectral irradiance detection head are combined with a very particular port geometry and a minimized baffle area. This results in a uniform spatial response distribution function (SRDF), which guarantees an accurate radiant and luminous flux determination, irrespective of the spatial intensity distribution of the LED package or luminaire. The effect of the directional response of the detector head on the SRDF has been explored. Measurements on LED devices with and without external optics are presented, illustrating the possibilities of the measurement setup.

  14. A new integrating sphere design for spectral radiant flux determination of light-emitting diodes

    International Nuclear Information System (INIS)

    Hanselaer, P; Keppens, A; Forment, S; Ryckaert, W R; Deconinck, G

    2009-01-01

    Light-emitting diode (LED) technology is developing very quickly and may be considered an alternative for traditional light sources. However, at this moment, manufacturers and end users of LEDs are facing a rather basic but major problem. The lack of standardization regarding optical and electrical characterization of LEDs appears to compromise a successful implementation. In particular, numbers quoted for the luminous flux, and consequently for the efficacy of LEDs, are very sensitive data because they are used to impress and push the LED market. In this paper, the most was made of the typical hemispherical radiation of high-power LEDs to increase the accuracy of the flux determination using a custom-made integrating sphere. Recently developed measurement techniques such as the use of an external spectral irradiance standard and an optimized spectral irradiance detection head are combined with a very particular port geometry and a minimized baffle area. This results in a uniform spatial response distribution function (SRDF), which guarantees an accurate radiant and luminous flux determination, irrespective of the spatial intensity distribution of the LED package or luminaire. The effect of the directional response of the detector head on the SRDF has been explored. Measurements on LED devices with and without external optics are presented, illustrating the possibilities of the measurement setup

  15. beta. and. gamma. -comparative dose estimates on Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L. (California Univ., Livermore (USA). Lawrence Livermore National Lab.)

    1982-05-01

    Enewetak Atoll in the Pacific is used for atmospheric testing of U.S. nuclear weapons. Beta dose and ..gamma..-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the ..beta.. and low energy ..gamma..-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a ..beta..-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to ..beta..- or low energy ..gamma..-contribution. The contribution at any particular site, however, is reduced by vegetation. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey. Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the ..beta..'s or low energy ..gamma..'s, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  16. Integrated chemical sensor array platform based on a light emitting diode, xerogel-derived sensor elements, and high-speed pin printing

    International Nuclear Information System (INIS)

    Cho, Eun Jeong; Bright, Frank V.

    2002-01-01

    We report a new, solid-state, integrated optical array sensor platform. By using pin printing technology in concert with sol-gel-processing methods, we form discrete xerogel-based microsensor elements that are on the order of 100 μm in diameter and 1 μm thick directly on the face of a light emitting diode (LED). The LED serves as the light source to excite chemically responsive luminophores sequestered within the doped xerogel microsensors and the analyte-dependent emission from within the doped xerogel is detected with a charge coupled device (CCD). We overcome the problem of background illumination from the LED reaching the CCD and the associated biasing that results by coating the LED first with a thin layer of blue paint. The thin paint layer serves as an optical filter, knocking out the LEDs red-edge spectral tail. The problem of the spatially-dependent fluence across the LED face is solved entirely by performing ratiometric measurements. We illustrate the performance of the new sensor scheme by forming an array of 100 discrete O 2 -responsive sensing elements on the face of a single LED. The combination of pin printing with an integrated sensor and light source platform results in a rapid method of forming (∼1 s per sensor element) reusable sensor arrays. The entire sensor array can be calibrated using just one sensor element. Array-to-array reproducibly is <8%. Arrays can be formed using single or multiple pins with indistinguishable analytical performance

  17. Light-driven photosensitizer uptake increases Candida albicans photodynamic inactivation.

    Science.gov (United States)

    Romano, Renan A; Pratavieira, Sebastião; Silva, Ana P da; Kurachi, Cristina; Guimarães, Francisco E G

    2017-11-01

    Photodynamic Inactivation (PDI) is based on the use of a photosensitizer (PS) and light that results mainly in the production of reactive oxygen species, aiming to produce microorganism cell death. PS incubation time and light dose are key protocol parameters that influence PDI response; the correct choice of them can increase the efficiency of inactivation. The results of this study show that a minor change in the PDI protocol, namely light-driven incubation leads to a higher photosensitizer and more uniform cell uptake inside the irradiated zone. Furthermore, as the uptake increases, the damage caused by PDI also increases. The proposed light-driven incubation prior to the inactivation illumination dose has advantages when compared to the traditional PDI treatments since it can be more selective and effective. Using a violet light as pre-illumination (light-driven incubation) source and a red-light system as PDI source, it was possible to demonstrate that when compared to the traditional protocol of dark incubation, the pre-illuminated cell culture showed an inactivation increase of 7 log units. These in vitro results performed in Candida albicans cells may result in the introduction of a new protocol for PDI. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. CDApps: integrated software for experimental planning and data processing at beamline B23, Diamond Light Source.

    Science.gov (United States)

    Hussain, Rohanah; Benning, Kristian; Javorfi, Tamas; Longo, Edoardo; Rudd, Timothy R; Pulford, Bill; Siligardi, Giuliano

    2015-03-01

    The B23 Circular Dichroism beamline at Diamond Light Source has been operational since 2009 and has seen visits from more than 200 user groups, who have generated large amounts of data. Based on the experience of overseeing the users' progress at B23, four key areas requiring the most assistance are identified: planning of experiments and note-keeping; designing titration experiments; processing and analysis of the collected data; and production of experimental reports. To streamline these processes an integrated software package has been developed and made available for the users. The subsequent article summarizes the main features of the software.

  19. Dose and dose reduction in computed tomography; Dosis und Dosisreduktion in der Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Lell, Michael [Klinikum Nuernberg (Germany). Inst. fuer Radiologie und Nuklearmedizin; Paracelsus Medical Univ. Nuernberg (Germany); Wucherer, Michael [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik; Kachelriess, Marc [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany)

    2017-06-15

    CT is widely used in medical imaging due to high availability, relatively low cost, and excellent diagnostic yield. Newer applications like coronary CTA, CT colonography, and CT perfusion imaging are integrated in clinical pathways. Although there is a high level of consensus that the benefits of CT exceeds the risks of radiation exposure for appropriate indications, concerns have been raised regarding the potential of cancer induction. Keeping dose as low as reasonably achievable remains the most important task. Dose reduction strategies are presented and discussed.

  20. A smartphone colorimetric reader integrated with an ambient light sensor and a 3D printed attachment for on-site detection of zearalenone.

    Science.gov (United States)

    Chen, Yuan; Fu, Qiangqiang; Li, Dagang; Xie, Jun; Ke, Dongxu; Song, Qifang; Tang, Yong; Wang, Hong

    2017-11-01

    Smartphone biosensors could be cost-effective, portable instruments to be used for the readout of liquid colorimetric assays. However, current reported smartphone colorimetric readers have relied on photos of liquid assays captured using a camera, and then analyzed using software programs. This approach results in a relatively low accuracy and low generality. In this work, we reported a novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays. The portable and low-cost ($0.15) reader utilized a simplified electronic and light path design. Furthermore, our reported smartphone colorimetric reader can be compatible with different smartphones. As a proof of principle, the utility of this device was demonstrated using it in conjunction with an enzyme-linked immunosorbent assay to detect zearalenone. Results were consistent with those obtained using a professional microplate reader. The developed smartphone colorimetric reader was capable of providing scalable, cost-effective, and accurate results for liquid colorimetric assays that related to clinical diagnoses, environment pollution, and food testing. Graphical abstract A novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays.

  1. Polarized light improves cutaneous healing on diabetic rats

    Science.gov (United States)

    Ramalho, Luciana Maria Pedreira; Oliveira, Priscila Chagas; Marques, Aparecida Maria Cordeiro; Barbosa Pinheiro, Antonio L.

    2010-02-01

    The aim of this study was to evaluate the healing of 3rd degree burn on diabetic rats submitted or not to treatment with Polarized Light. Diabetes mellitus (Streptozotocin, 60mg/kg) was induced on 45 male Wistar albinus rats and a third degree burn (1.5× 1.5cm) was created in the dorsum of each animal under general anesthesia. After a regular quarantine period, the animals were randomly distributed into three groups as follows: G1: control (no treatment, n =15); G2: Polarized Light (λ=400-2000nm, 20J/cm2) and G3: Polarized Light (λ=400-2000nm, 40J/cm2). The phototherapy performed on group G2 was Polarized Light dose 20J/cm2 and G3 was Polarized Light dose 40J/cm2 (Bioptron®, λ400-2000 nm, 40mW; 2.4J/cm2 per minute; Φ +/- 5.5 cm; Bioptron AG, Monchaltorf, Switzerland). The phototherapy started immediately post-burning and was repeated daily until the day before the animal death. The energy was applied transcutaneously respecting the focal distance of 10cm as recommended by the manufacturer. The dose was 20 or 40J/cm2 (4min 15s or 8min.and 30s). At each time point chosen (7, 14, and 21 days post-burning) and following macroscopic examination, each animal was killed by an overdose of general anesthesia. Slides were stained with HE, Sirius Red, and CK AE1/AE3 antibody. Qualitative and semi-quantitative analyses were performed under light microscopy. The animals submitted to phototherapy (20J/cm2) showed significant differences on regards revascularization and epithelialization. The use of 20J/cm2 was effective on improving the healing of third degree buns on diabetic animals at both early and late stages of the repair.

  2. Treatment planning using tailored and standard cylindrical light diffusers for photodynamic therapy of the prostate

    International Nuclear Information System (INIS)

    Rendon, Augusto; Lilge, Lothar; Beck, J Christopher

    2008-01-01

    Interstitial photodynamic therapy (PDT) has seen a rebirth, partially prompted by the development of photosensitizers with longer absorption wavelengths that enable the treatment of larger tissue volumes. Here, we study whether using diffusers with customizable longitudinal emission profiles, rather than conventional ones with flat emission profiles, improves our ability to conform the light dose to the prostate. We present a modified Cimmino linear feasibility algorithm to solve the treatment planning problem, which improves upon previous algorithms by (1) correctly minimizing the cost function that penalizes deviations from the prescribed light dose, and (2) regularizing the inverse problem. Based on this algorithm, treatment plans were obtained under a variety of light delivery scenarios using 5-15 standard or tailored diffusers. The sensitivity of the resulting light dose distributions to uncertainties in the optical properties, and the placement of diffusers was also studied. We find that tailored diffusers only marginally outperform conventional ones in terms of prostate coverage and rectal sparing. Furthermore, it is shown that small perturbations in optical properties can lead to large changes in the light dose distribution, but that those changes can be largely corrected with a simple light dose re-normalization. Finally, we find that prostate coverage is only minimally affected by small changes in diffuser placement. Our results suggest that prostate PDT is not likely to benefit from the use of tailored diffusers. Other locations with more complex geometries might see a better improvement

  3. Genotype, explant, medium, light and radiation effects on the in vitro plant regeneration in alfalfa (Medicago Sativa L.)

    International Nuclear Information System (INIS)

    El-Fiki, A.A.; Abdel-Hameed, A.A.M.; Sayed, A.I.H.

    2005-01-01

    The relative importance of genotype, explants, radiation, medium and light and their interactions for in vitro plant regeneration via somatic embryogenesis in alfalfa (Medicago sativa L.) has been studied. Shoot and leaf explants of two commercially grown Egyptian cultivars, Al-Wadi Al-Gadid and Siwa Tarkibi, were used in the study. The effect of gamma radiation doses 40, 80, 120 and 160 Gy were negative on plant regeneration, in spite of increase with some treatments. The best results of plant regeneration were obtained with dose 40 Gy with control light regime (16 h) on MS + 0.5 mg NAA + 1.5 mg BAP in both shoot and leaf explants of cv. Al-Wadi. The shoot explant of cv. Siwa was sensitive for gamma radiation dose 40 Gy while affirmative effect was obtained in leaf explant on MS + 1.0 mg NAA + 0.5 mg BAP with control light regime. However, dose 80 Gy showed the best results on MS + 0.5 mg NAA + 0.5 mg BAP in shoot and leaf explants of both cultivars, with control light regime in shoot explant and dark/light (DL) and dark/dark (DD) in leaf explant of cv. Al-Wadi, while with light/dark (LD) in shoot explant and control light regime in leaf explant of cv. Siwa. On the other hand, the highest plant regeneration ratio observed with dose 120 Gy were on 1.5 mg NAA + 0.5 mg BAP with control light regime in shoot and leaf explants of cv. Al-Wadi but on 0.5 mg NAA + 0.5 mg BAP with control and dark/light (DL) light regime in shoot and leaf explants of cv. Siwa. Whereas, the radiation dose 160 Gy showed severe effect on plant regeneration in both cultivars but highest percentage was observed on MS + 0.5 mg NAA + 0.5 mg BAP with dark/light (DL) in shoot explant, MS + 0.5 mg NAA + 1.5 mg BAP with control light regime in leaf explant of cv. Al-Wadi, MS + 0.5 mg NAA + 1.5 mg BAP in shoot explant and MS + 0.5 mg NAA + 0.5 mg BAP in leaf explant with dark/light (DL) in cv. Siwa. However, the effects of the same doses on callus growth showed that the highest callus weight was

  4. Human responses to bright light of different durations.

    Science.gov (United States)

    Chang, Anne-Marie; Santhi, Nayantara; St Hilaire, Melissa; Gronfier, Claude; Bradstreet, Dayna S; Duffy, Jeanne F; Lockley, Steven W; Kronauer, Richard E; Czeisler, Charles A

    2012-07-01

    Light exposure in the early night induces phase delays of the circadian rhythm in melatonin in humans. Previous studies have investigated the effect of timing, intensity, wavelength, history and pattern of light stimuli on the human circadian timing system. We present results from a study of the duration–response relationship to phase-delaying bright light. Thirty-nine young healthy participants (16 female; 22.18±3.62 years) completed a 9-day inpatient study. Following three baseline days, participants underwent an initial circadian phase assessment procedure in dim light (light pulse (∼10,000 lux) of 0.2 h, 1.0 h, 2.5 h or 4.0 h duration during a 4.5 h controlled-posture episode centred in a 16 h wake episode. After another 8 h sleep episode, participants completed a second circadian phase assessment. Phase shifts were calculated from the difference in the clock time of the dim light melatonin onset (DLMO) between the initial and final phase assessments. Exposure to varying durations of bright light reset the circadian pacemaker in a dose-dependent, non-linear manner. Per minute of exposure, the 0.2 h duration was over 5 times more effective at phase delaying the circadian pacemaker (1.07±0.36 h) as compared with the 4.0 h duration (2.65±0.24 h). Acute melatonin suppression and subjective sleepiness also had a dose-dependent response to light exposure duration. These results provide strong evidence for a non-linear resetting response of the human circadian pacemaker to light duration.

  5. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  6. Structurally Integrated Photoluminescence-Based Lactate Sensor Using Organic Light Emitting Devices (OLEDs) as the Light Source

    International Nuclear Information System (INIS)

    Chengliang Qian

    2006-01-01

    Multianalyte bio(chemical) sensors are extensively researched for monitoring analytes in complex systems, such as blood serum. As a step towards developing such multianalyte sensors, we studied a novel, structurally integrated, organic light emitting device (OLED)-based sensing platform for detection of lactate. Lactate biosensors have attracted numerous research efforts, due to their wide applications in clinical diagnosis, athletic training and food industry. The OLED-based sensor is based on monitoring the oxidation reaction of lactate, which is catalyzed by the lactate oxidase (LOX) enzyme. The sensing component is based on an oxygen-sensitive dye, Platinum octaethyl porphyrin (PtOEP), whose photoluminescence (PL) lifetime τ decreases as the oxygen level increases. The PtOEP dye was embedded in a thin film polystyrene (PS) matrix; the LOX was dissolved in solution or immobilized in a sol-gel matrix. τ was measured as a function of the lactate concentration; as the lactate concentration increases, τ increases due to increased oxygen consumption. The sensors performance is discussed in terms of the detection sensitivity, dynamic range, and response time. A response time of ∼32 sec was achieved when the LOX was dissolved in solution and kept in a closed cell. Steps towards development of a multianalyte sensor array using an array of individually addressable OLED pixels were also presented

  7. Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics

    International Nuclear Information System (INIS)

    Vedelago, J.; Valente, M.; Mattea, F.

    2017-10-01

    The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. This work presents preliminary results of properly synthesized and purify silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. (Author)

  8. Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J.; Valente, M. [Instituto de Fisica Enrique Gaviola - CONICET, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina); Mattea, F., E-mail: jvedelago@famaf.unc.edu.ar [Universidad Nacional de Cordoba, FAMAF, Laboratorio de Investigacion e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina)

    2017-10-15

    The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. This work presents preliminary results of properly synthesized and purify silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. (Author)

  9. Light intensity modulation in phototherapy

    Science.gov (United States)

    Lukyanovich, P. A.; Zon, B. A.; Kunin, A. A.; Pankova, S. N.

    2015-04-01

    A hypothesis that blocking ATP synthesis is one of the main causes of the stimulating effect is considered based on analysis of the primary photostimulation mechanisms. The light radiation intensity modulation is substantiated and the estimates of such modulation parameters are made. An explanation is offered to the stimulation efficiency decrease phenomenon at the increase of the radiation dose during the therapy. The results of clinical research of the medical treatment in preventive dentistry are presented depending on the spectrum and parameters of the light flux modulation.

  10. Ultraviolet light: sterile water without chlorine smell and taste

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The use of chlorine and hypochlorite is necessary in larger waterworks, but it is a disadvantage in smaller plants, where overtreatment easily leads to smell and taste of chlorine in the water. Ultraviolet light with a wavelength of 2535 Angstrom gives 100% disinfection with a dose of 10 mWs/cm 2 for all known bacteria. In practice a dose of 40 mWs/cm 2 and an irradiation time of 15 minutes is desireable. A standard unit utilising six UV light tubes arranged concentrically around a quartz tube, through which the water flows, is described briefly. (JIW)

  11. Ultraviolet light: sterile water without chlorine smell and taste

    Energy Technology Data Exchange (ETDEWEB)

    1977-02-14

    The use of chlorine and hypochlorite is necessary in larger waterworks, but it is a disadvantage in smaller plants, where overtreatment easily leads to smell and taste of chlorine in the water. Ultraviolet light with a wavelength of 2535 Angstrom gives 100% disinfection with a dose of 10 mWs/cm/sup 2/ for all known bacteria. In practice a dose of 40 mWs/cm/sup 2/ and an irradiation time of 15 minutes is desireable. A standard unit utilising six UV light tubes arranged concentrically around a quartz tube, through which the water flows, is described briefly.

  12. Integrated development of light armored vehicles based on wargaming simulators

    Science.gov (United States)

    Palmarini, Marc; Rapanotti, John

    2004-08-01

    Vehicles are evolving into vehicle networks through improved sensors, computers and communications. Unless carefully planned, these complex systems can result in excessive crew workload and difficulty in optimizing the use of the vehicle. To overcome these problems, a war-gaming simulator is being developed as a common platform to integrate contributions from three different groups. The simulator, OneSAF, is used to integrate simplified models of technology and natural phenomena from scientists and engineers with tactics and doctrine from the military and analyzed in detail by operations analysts. This approach ensures the modelling of processes known to be important regardless of the level of information available about the system. Vehicle survivability can be improved as well with better sensors, computers and countermeasures to detect and avoid or destroy threats. To improve threat detection and reliability, Defensive Aids Suite (DAS) designs are based on three complementary sensor technologies including: acoustics, visible and infrared optics and radar. Both active armour and softkill countermeasures are considered. In a typical scenario, a search radar, providing continuous hemispherical coverage, detects and classifies the threat and cues a tracking radar. Data from the tracking radar is processed and an explosive grenade is launched to destroy or deflect the threat. The angle of attack and velocity from the search radar can be used by the soft-kill system to carry out an infrared search and track or an illuminated range-gated scan for the threat platform. Upon detection, obscuration, countermanoeuvres and counterfire can be used against the threat. The sensor suite is completed by acoustic detection of muzzle blast and shock waves. Automation and networking at the platoon level contribute to improved vehicle survivability. Sensor data fusion is essential in avoiding catastrophic failure of the DAS. The modular DAS components can be used with Light Armoured

  13. Handbook of advanced lighting technology

    CERN Document Server

    Sun, Ching-Cherng; Zissis, Georges; Ma, Ruiqing

    2017-01-01

    The Handbook of Advanced Lighting Technology is a major reference work on the subject of light source science and technology, with particular focus on solid-state light sources – LEDs and OLEDs – and the development of 'smart' or 'intelligent' lighting systems; and the integration of advanced light sources, sensors, and adaptive control architectures to provide tailored illumination which is 'fit to purpose.' The concept of smart lighting goes hand-in-hand with the development of solid-state light sources, which offer levels of control not previously available with conventional lighting systems. This has impact not only at the scale of the individual user, but also at an environmental and wider economic level. These advances have enabled and motivated significant research activity on the human factors of lighting, particularly related to the impact of lighting on healthcare and education, and the Handbook provides detailed reviews of work in these areas. The potential applications for smart lighting span ...

  14. Performance evaluation of domestic prototype dose area product meter SFT-1

    International Nuclear Information System (INIS)

    Lee, Ho Sun; Han, Seong Gyu; Roh, Young Roh; Lim, Hyun Jong; Kim, Jung Min; Kim, Jong Uk; Chae, Hyun Sik; Yoon, Yong Su

    2016-01-01

    The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R and BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product. Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatabilit y coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria

  15. Dose distribution of non-coplanar irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Toshiharu; Wada, Yoichi; Takenaka, Eiichi

    1987-02-01

    Non-coplanar irradiations were applied to the treatment of brain tumor. The dose distribution around the target area due to non-coplanar irradiation was half less than the dose when coplanar irradiation used. Integral volume dose due to this irradiation was not always less than that due to conventional opposing or rotational irradiation. This irradiation has the better application to the following;as a boost therapy, glioblastoma multiforme;as a radical therapy, recurrent brain tumor, well differentiated brain tumor such as craniopharyngioma, hypophyseal tumor etc and AV-malformation.

  16. External doses from radioactive fallout. Dosimetry and levels

    International Nuclear Information System (INIS)

    Woehni, T.

    1995-01-01

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF 2 with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs

  17. External doses from radioactive fallout. Dosimetry and levels

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T

    1996-12-31

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF{sub 2} with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs.

  18. External doses from radioactive fallout. Dosimetry and levels

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T.

    1995-12-31

    The design, manufacture and calibration of a TL-based dosemeter for measurement of low level external photon radiation are presented. The dosemeter is based on CaF{sub 2} with 2 mm brass filter for energy compensation. It is able to resolve a 8% dose increase relative to natural background radiation. With this dosemeter external dose measurements were made in 6 villages in a heavily contaminated region in Russia (Chernobyl fallout), in order to assess external doses to the population. The results were analyzed in the light of additional existing information on radioactive deposition, social habits, decontamination measures and other influencing technical and physical factors. The observed dose values were lower than theoretical estimates of external doses based on published values for external dose levels relative to the level of contamination. 84 refs., 7 figs., 5 tabs.

  19. Rectangular-section mirror light pipes

    Energy Technology Data Exchange (ETDEWEB)

    Swift, P.D.; Lawlor, R. [School of Physical Sciences, Dublin City University, Dublin 9 (Ireland); Smith, G.B.; Gentle, A. [Department of Applied Physics, University of Technology, Sydney, Broadway, NSW 2007 (Australia)

    2008-08-15

    Using an integrated-ray approach an expression for the transmission of rectangular section mirror light pipe (MLP) has been derived for the case of collimated light input. The transmittance and the irradiance distribution at the exit aperture of rectangular-section MLPs have been measured experimentally and calculated theoretically for the case of collimated light input. The results presented extend the description of MLPs from the cylindrical case. Measured and calculated transmittances and irradiance distributions are in good agreement. (author)

  20. Integrated Automotive High-Power LED-Lighting Systems in 3D-MID Technology

    NARCIS (Netherlands)

    Thomas, W.

    2014-01-01

    The growing energy consumption of lighting as well as rising luminous efficacies and -fluxes of high-power Light Emitting Diodes (LEDs) have contributed to the widespread use of LEDs in modern lighting systems. One of the most prominent users of the LED-technology is automotive (exterior) lighting.

  1. Integrated pharmacokinetics/pharmacodynamics parameters-based dosing guidelines of enrofloxacin in grass carp Ctenopharyngodon idella to minimize selection of drug resistance.

    Science.gov (United States)

    Xu, Lijuan; Wang, Hao; Yang, Xianle; Lu, Liqun

    2013-06-25

    Antibiotic resistance has become a serious global problem and is steadily increasing worldwide in almost every bacterial species treated with antibiotics. In aquaculture, the therapeutic options for the treatment of A. hydrophila infection were only limited to several antibiotics, which contributed for the fast-speed emergence of drug tolerance. Accordingly, the aim of this study was to establish a medication regimen to prevent drug resistant bacteria. To determine a rational therapeutic guideline, integrated pharmacodynamics and pharmacokinetics parameters were based to predict dose and dosage interval of enrofloxacin in grass carp Ctenopharyngodon idella infected by a field-isolated A. hydrophila strain. The pathogenic A. hydrophila strain (AH10) in grass carp was identified and found to be sensitive to enrofloxacin. The mutant selection window (MSW) of enrofloxacin on isolate AH10 was determined to be 0.5-3 μg/mL based on the mutant prevention concentration (MPC) and minimum inhibitory concentration (MIC) value. By using high-performance liquid chromatography (HPLC) system, the Pharmacokinetic (PK) parameters of enrofloxacin and its metabolite ciprofloxacin in grass carp were monitored after a single oral gavage of 10, 20, 30 μg enrofloxacin per g body weight. Dosing of 30 μg/g resulted in serum maximum concentration (Cmax) of 7.151 μg/mL, and concentration in serum was above MPC till 24 h post the single dose. Once-daily dosing of 30 μg/g was determined to be the rational choice for controlling AH10 infection and preventing mutant selection in grass carp. Data of mean residue time (MRT) and body clearance (CLz) indicated that both enrofloxacin and its metabolite ciprofloxacin present similar eliminating rate and pattern in serum, muscle and liver. A withdraw time of more than 32 d was suggested based on the drug eliminating rate and pharmacokinetic model described by a polyexponential equation. Based on integrated PK/PD parameters (AUC/MIC, Cmax/MIC, and T

  2. Photon dose conversion coefficients for the human teeth in standard irradiation geometries

    Energy Technology Data Exchange (ETDEWEB)

    Ulanovsky, A; Wieser, A; Zankl, M; Jacob, P

    2005-07-01

    Photon dose conversion coefficients for the human tooth materials are computed in energy range from 0.01 to 10 MeV by the Monte Carlo method. The voxel phantom Golem of the human body with newly defined tooth region and a modified version of the EGS4 code have been used to compute the coefficients for 30 tooth cells with different locations and materials. The dose responses are calculated for cells representing buccal and lingual enamel layers. The computed coefficients demonstrate a strong dependence on energy and geometry of the radiation source and a weaker dependence on location of the enamel voxels. For isotropic and rotational radiation fields the enamel dose does not show a significant dependence on tooth sample locations. The computed coefficients are used to convert from absorbed dose in teeth to organ dose or to integral air kerma. Examples of integral conversion factors from enamel dose to air kerma are given for several photon fluences specific for the Mayak reprocessing plant in Russia. The integral conversion factors are strongly affected by the energy and angular distributions of photon fluence, which are important characteristics of an exposure scenario for reconstruction of individual occupational doses. (orig.)

  3. Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons

    International Nuclear Information System (INIS)

    Mukherjee, B.; Simrock, S.; Khachan, J.; Rybka, D.; Romaniuk, R.

    2007-01-01

    Displacement damage (DD) caused by fast neutrons in unbiased Gallium Arsenide (GaAs) light emitting diodes (LED) resulted in a reduction of the light output. On the other hand, a similar type of LED irradiated with gamma rays from a 60 Co source up to a dose level in excess of 1.0 kGy (1.0 x 10 5 rad) was found to show no significant drop of the light emission. This phenomenon was used to develop a low cost passive fluence monitor and kinetic energy released per unit mass dosemeter for accelerator-produced neutrons. These LED-dosemeters were used to assess the integrated fluence of photoneutrons, which were contaminated with a strong Bremsstrahlung gamma-background generated by the 730 MeV superconducting electron linac driving the free electron laser in Hamburg (FLASH) at Deutsches Elektronen-Synchrotron. The applications of GaAs LED as a routine neutron fluence monitor and DD precursor for the electronic components located in high-energy accelerator environment are highlighted. (authors)

  4. Dose Rate Determination from Airborne Gamma-ray Spectra

    DEFF Research Database (Denmark)

    Bargholz, Kim

    1996-01-01

    The standard method for determination of ground level dose rates from airborne gamma-ray is the integral count rate which for a constant flying altitude is assumed proportional to the dose rate. The method gives reasonably results for natural radioactivity which almost always has the same energy...

  5. Population pharmacokinetic model of THC integrates oral, intravenous, and pulmonary dosing and characterizes short- and long-term pharmacokinetics.

    Science.gov (United States)

    Heuberger, Jules A A C; Guan, Zheng; Oyetayo, Olubukayo-Opeyemi; Klumpers, Linda; Morrison, Paul D; Beumer, Tim L; van Gerven, Joop M A; Cohen, Adam F; Freijer, Jan

    2015-02-01

    Δ(9)-Tetrahydrocannobinol (THC), the main psychoactive compound of Cannabis, is known to have a long terminal half-life. However, this characteristic is often ignored in pharmacokinetic (PK) studies of THC, which may affect the accuracy of predictions in different pharmacologic areas. For therapeutic use for example, it is important to accurately describe the terminal phase of THC to describe accumulation of the drug. In early clinical research, the THC challenge test can be optimized through more accurate predictions of the dosing sequence and the wash-out between occasions in a crossover setting, which is mainly determined by the terminal half-life of the compound. The purpose of this study is to better quantify the long-term pharmacokinetics of THC. A population-based PK model for THC was developed describing the profile up to 48 h after an oral, intravenous, and pulmonary dose of THC in humans. In contrast to earlier models, the current model integrates all three major administration routes and covers the long terminal phase of THC. Results show that THC has a fast initial and intermediate half-life, while the apparent terminal half-life is long (21.5 h), with a clearance of 38.8 L/h. Because the current model characterizes the long-term pharmacokinetics, it can be used to assess the accumulation of THC in a multiple-dose setting and to forecast concentration profiles of the drug under many different dosing regimens or administration routes. Additionally, this model could provide helpful insights into the THC challenge test used for the development of (novel) compounds targeting the cannabinoid system for different therapeutic applications and could improve decision making in future clinical trials.

  6. A remotely operated drug delivery system with dose control

    KAUST Repository

    Yi, Ying; Kosel, Jü rgen

    2017-01-01

    include an effective actuation stimulus and a controllable dose release mechanism. This work focuses on remotely powering an implantable drug delivery system and providing a high degree of control over the released dose. This is accomplished by integration

  7. MELODI: The 'Multidisciplinary European Low-Dose Initiative'

    International Nuclear Information System (INIS)

    Belli, M.; Salomaa, S.; Ottolenghi, A.

    2011-01-01

    The importance of research to reduce uncertainties in risk assessment of low and protracted exposures is now recognised globally. In Europe a new initiative, called 'Multidisciplinary European Low Dose Initiative' (MELODI), has been proposed by a 'European High Level and Expert Group on low-dose risk research' (www.hleg.de), aimed at integrating national and EC (Euratom) efforts. Five national organisations: BfS (DE), CEA (FR), IRSN (FR), ISS (IT) and STUK (FI), with the support of the EC, have initiated the creation of MELODI by signing a letter of intent. In the forthcoming years, MELODI will integrate in a step-by-step approach EU institutions with significant programmes in the field and will be open to other scientific organisations and stakeholders. A key role of MELODI is to develop and maintain over time a strategic research agenda (SRA) and a road map of scientific priorities within a multidisciplinary approach, and to transfer the results for the radiation protection system. Under the coordination of STUK a network has been proposed in the 2009 Euratom Programme, called DoReMi (Low-Dose Research towards Multidisciplinary Integration), which can help the integration process within the MELODI platform. DoReMi and the First MELODI Open Workshop, organised by BfS in September 2009, are now important inputs for the European SRA. (authors)

  8. Basic dose response of fluorescent screen-based portal imaging device

    International Nuclear Information System (INIS)

    Yeo, In Hwan; Yonannes, Yonas; Zhu, Yunping

    1999-01-01

    The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDs). We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as 7%. We also found that scintillation light scattering within the EPID system is an important source of error. This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system

  9. Sustainable indoor lighting

    CERN Document Server

    Mercatelli, Luca; Farini, Alessandro

    2015-01-01

    Encompassing a thorough survey of the lighting techniques applied to internal illumination characterized by high efficiency, optimized color and architectural integration, a consolidated summary of the latest scientific, technical and architectural research is presented in order to give the reader an overview of the different themes with their interactions and mutual effects.   This book describes light principles, methodologies and realisations for indoor illumination at low consumption. Power efficiency, color characteristics and architectural aspects are analyzed in terms of their  practical application, with the interactions between scientific, technological and architectural features considered in order to supply a complete overview, which can be read both at technical level and at user level. Introducing photometric and radiometric quantities and laws, the book first discusses tests and measurements assessing lighting and color characteristics before examining in detail artificial light sources with p...

  10. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    Science.gov (United States)

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Radiochromic film as a radiotherapy surface-dose detector

    International Nuclear Information System (INIS)

    Butson, M.J.; Metcalfe, P.E.; Wollongong Univ., NSW; Mathur, J.N.

    1996-01-01

    Radiochromic film is shown to be a useful surface-dose detector for radiotherapy x-ray beams. Central-axis percentage surface-dose results as measured by Gafchromic film for a 6 MVp x-ray beam produced by a Varian 2100C Linac at 100 cm SSD are 16%, 25%, 35%, 41% for 10, 20, 30 and 40 cm square field sizes, respectively. Using a simple, uniform light source and a CCD camera connected to an image analysis system, quantitative 3D surface doses are accurately attainable in real time as either numerical data, a black-and-white image or a colour-enhanced image. (Author)

  12. Loss of Melanopsin Photoreception and Antagonism of the Histamine H3 Receptor by Ciproxifan Inhibit Light-Induced Sleep in Mice.

    Directory of Open Access Journals (Sweden)

    Fanuel Muindi

    Full Text Available Light has direct effects on sleep and wakefulness causing arousal in diurnal animals and sleep in nocturnal animals. In the present study, we assessed the modulation of light-induced sleep by melanopsin and the histaminergic system by exposing mice to millisecond light flashes and continuous light respectively. First, we show that the induction of sleep by millisecond light flashes is dose dependent as a function of light flash number. We found that exposure to 60 flashes of light occurring once every 60 seconds for 1-h (120-ms of total light over an hour induced a similar amount of sleep as a continuous bright light pulse. Secondly, the induction of sleep by millisecond light flashes was attenuated in the absence of melanopsin when animals were presented with flashes occurring every 60 seconds over a 3-h period beginning at ZT13. Lastly, the acute administration of a histamine H3 autoreceptor antagonist, ciproxifan, blocked the induction of sleep by a 1-h continuous light pulse during the dark period. Ciproxifan caused a decrease in NREMS delta power and an increase in theta activity during both sleep and wake periods respectively. The data suggest that some form of temporal integration occurs in response to millisecond light flashes, and that this process requires melanopsin photoreception. Furthermore, the pharmacological data suggest that the increase of histaminergic neurotransmission is sufficient to attenuate the light-induced sleep response during the dark period.

  13. Drinking and driving behavior at stop signs and red lights.

    Science.gov (United States)

    Wan, Jingyan; Wu, Changxu; Zhang, Yiqi; Houston, Rebecca J; Chen, Chang Wen; Chanawangsa, Panya

    2017-07-01

    Alcohol is one of the principal risk factors for motor vehicle crashes. One factor that contributes to vehicle crashes is noncompliance with stop signs and red lights. The present experiment investigated the effects of alcohol and drinking patterns on driving behavior at stop signs and red lights. 28 participants participated in drinking and simulated driving sessions during which they received a moderate dose of alcohol (0.08% BAC) or a placebo. Simulated driving tasks measured participants' driving performance at stop signs and red lights in response to each dose. Results suggested that alcohol impaired the driver control of speed and direction and prolonged their simple and complex reaction time, which were exhibited by impaired speed and lateral control, longer reaction time when the lights turned yellow, and lower deceleration towards stop signs and red lights. Visual degradation may also occur under alcohol intake. It was also suggested that alcohol impaired non-binge drinkers more severely. To be specific, higher acceleration was observed in impaired non-binge drinkers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Optimization of light source parameters in the photodynamic therapy of heterogeneous prostate

    International Nuclear Information System (INIS)

    Li Jun; Altschuler, Martin D; Hahn, Stephen M; Zhu, Timothy C

    2008-01-01

    The three-dimensional (3D) heterogeneous distributions of optical properties in a patient prostate can now be measured in vivo. Such data can be used to obtain a more accurate light-fluence kernel. (For specified sources and points, the kernel gives the fluence delivered to a point by a source of unit strength.) In turn, the kernel can be used to solve the inverse problem that determines the source strengths needed to deliver a prescribed photodynamic therapy (PDT) dose (or light-fluence) distribution within the prostate (assuming uniform drug concentration). We have developed and tested computational procedures to use the new heterogeneous data to optimize delivered light-fluence. New problems arise, however, in quickly obtaining an accurate kernel following the insertion of interstitial light sources and data acquisition. (1) The light-fluence kernel must be calculated in 3D and separately for each light source, which increases kernel size. (2) An accurate kernel for light scattering in a heterogeneous medium requires ray tracing and volume partitioning, thus significant calculation time. To address these problems, two different kernels were examined and compared for speed of creation and accuracy of dose. Kernels derived more quickly involve simpler algorithms. Our goal is to achieve optimal dose planning with patient-specific heterogeneous optical data applied through accurate kernels, all within clinical times. The optimization process is restricted to accepting the given (interstitially inserted) sources, and determining the best source strengths with which to obtain a prescribed dose. The Cimmino feasibility algorithm is used for this purpose. The dose distribution and source weights obtained for each kernel are analyzed. In clinical use, optimization will also be performed prior to source insertion to obtain initial source positions, source lengths and source weights, but with the assumption of homogeneous optical properties. For this reason, we compare the

  15. Integrated light-guide plates that can control the illumination angle for liquid crystal display backlight system

    Science.gov (United States)

    Feng, Di; Yang, Xingpeng; Jin, Guofan; Yan, Yingbai; Fan, Shoushan

    2006-01-01

    Liquid crystal displays (LCDs) with edge-lit backlight systems offer several advantages, such as low energy consuming, low weight, and high uniformity of intensity, over traditional cathode-ray tube displays, and make them ideal for many applications including monitors in notebook personal computers, screens for TV, and many portable information terminals, such as mobile phones, personal digital assistants, etc. To satisfy market requirements for mobile and personal display panels, it is more and more necessary to modify the backlight system and make it thinner, lighter, and brighter all at once. In this paper, we have proposed a new integrated LGP based on periodic and aperiodic microprism structures by using polymethyl methacrylate material, which can be designed to control the illumination angle, and to get high uniformity of intensity. So the backlight system will be simplified to use only light sources and one LGP without using other optical sheets, such as reflection sheet, diffusion sheet and prism sheets. By using optimizing program and ray tracing method, the designed LGPs can achieve a uniformity of intensity better than 86%, and get a peak illumination angle from +400 to -200, without requiring other optical sheets. We have designed a backlight system with only one LED light source and one LGP, and other LGP design examples with different sizes (1.8 inches and 14.1 inches) and different light source (LED or CCFL), are performed also.

  16. A 2 x 2 imaging MIMO system based on LED Visible Light Communications employing space balanced coding and integrated PIN array reception

    DEFF Research Database (Denmark)

    Li, Jiehui; Xu, Yinfan; Shi, Jianyang

    2016-01-01

    In this paper, we proposed a 2 x 2 imaging Multi-Input Multi-Output (MIMO)-Visible Light Communication (VLC) system by employing Space Balanced Coding (SBC) based on two RGB LEDs and integrated PIN array reception. We experimentally demonstrated 1.4-Gbit/s VLC transmission at a distance of 2.5 m...

  17. Dose limits for ionising radiation

    International Nuclear Information System (INIS)

    Gifford, D.

    1989-01-01

    Dose limits for exposure to ionising radiation are assessed to see if they give sufficient protection both for the occupationally exposed and for the general public. It is concluded that current limits give a level of safety that satisfies the necessary criteria in the light of present knowledge and further reductions would be unlikely to improve standards of safety. (author)

  18. SKYSHIN: A computer code for calculating radiation dose over a barrier

    International Nuclear Information System (INIS)

    Atwood, C.L.; Boland, J.R.; Dickman, P.T.

    1986-11-01

    SKYSHIN is a computer code for calculating the radioactive dose (mrem), when there is a barrier between the point source and the receptor. The two geometrical configurations considered are: the source and receptor separated by a rectangular wall, and the source at the bottom of a cylindrical hole in the ground. Each gamma ray traveling over the barrier is assumed to be scattered at a single point. The dose to a receptor from such paths is numerically integrated for the total dose, with symmetry used to reduce the triple integral to a double integral. The buildup factor used along a straight line through air is based on published data, and extrapolated in a stable way to low energy levels. This buildup factor was validated by comparing calculated and experimental line-of-sight doses. The entire code shows good agreement to limited field data. The code runs on a CDC or on a Vax computer, and could be modified easily for others

  19. Committed dose equivalent in the practice of radiological protection

    International Nuclear Information System (INIS)

    Nenot, J.C.; Piechowski, J.

    1985-01-01

    In the case of internal exposure, the dose is not received at the moment of exposure, as happens with external exposure, since the incorporated radionuclide irradiates the various organs and tissues during the time it is present in the body. By definition, the committed dose equivalent corresponds to the received dose integrated over 50 years from the date of intake. In order to calculate it, one has to know the intake activity and the value of the committed dose equivalent per unit of intake activity. The uncertainties of the first parameter are such that the committed dose equivalent can only be regarded as an order of magnitude and not as a very accurate quantity. The use of it is justified, however, for, like the dose equivalent for external exposure, it expresses the risk of stochastic effects for the individual concerned since these effects, should they appear, would do so only after a latent period which is generally longer than the dose integration time. Moreover, the use of the committed dose equivalent offers certain advantages for dosimetric management, especially when it is simplified. A practical problem which may arise is that the annual dose limit is apparently exceeded by virtue of the fact that one is taking account, in the first year, of doses which will actually be received only in the following years. These problems are rare enough in practice to be dealt with individually in each case. (author)

  20. Measurements of dose with individual FAMOS transistors

    Energy Technology Data Exchange (ETDEWEB)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-12-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events.

  1. Measurements of dose with individual FAMOS transistors

    International Nuclear Information System (INIS)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-01-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events

  2. Gamma-ray spectra and doses from the Little Boy replica

    International Nuclear Information System (INIS)

    Moss, C.E.; Lucas, M.C.; Tisinger, E.W.; Hamm, M.E.

    1984-01-01

    Most radiation safety guidelines in the nuclear industry are based on the data concerning the survivors of the nuclear explosions at Hiroshima and Nagasaki. Crucial to determining these guidelines is the radiation from the explosions. We have measured gamma-ray pulse-height distributions from an accurate replica of the Little Boy device used at Hiroshima, operated at low power levels near critical. The device was placed outdoors on a stand 4 m from the ground to minimize environmental effects. The power levels were based on a monitor detector calibrated very carefully in independent experiments. High-resolution pulse-height distributions were acquired with a germanium detector to identify the lines and to obtain line intensities. The 7631 to 7645 keV doublet from neutron capture in the heavy steel case was dominant. Low-resolution pulse-height distributions were acquired with bismuth-germanate detectors. We calculated flux spectra from these distributions using accurately measured detector response functions and efficiency curves. We then calculated dose-rate spectra from the flux spectra using a flux-to-dose-rate conversion procedure. The integral of each dose-rate spectrum gave an integral dose rate. The integral doses at 2 m ranged from 0.46 to 1.03 mrem per 10 13 fissions. The output of the Little Boy replica can be calculated with Monte Carlo codes. Comparison of our experimental spectra, line intensities, and integral doses can be used to verify these calculations at low power levels and give increased confidence to the calculated values from the explosion at Hiroshima. These calculations then can be used to establish better radiation safety guidelines. 7 references, 7 figures, 2 tables

  3. Photobiomodulation delays the onset of skeletal muscle fatigue in a dose-dependent manner.

    Science.gov (United States)

    Larkin-Kaiser, Kelly A; Borsa, Paul A; Baweja, Harsimran S; Moore, Molly A; Tillman, Mark D; George, Steven Z; Christou, Evangelos A

    2016-09-01

    Photobiomodulation (PBM) therapy has been implicated as an effective ergogenic aid to delay the onset of muscle fatigue. The purpose of this study was to examine the dose-response ergogenic properties of PBM therapy and its ability to prolong time to task failure by enhancing muscle activity and delaying the onset of muscle fatigue using a static positioning task. Nine participants (24.3 ± 4.9 years) received three doses of near-infrared (NIR) light therapy randomly on three separate sessions (sham, 240, and 480 J). For the positioning task, participants held a 30 % one-repetition maximum (1-RM) load using the index finger until volitional fatigue. Surface electromyography (sEMG) of the first dorsal interosseous muscle was recorded for the length of the positioning task. Outcomes included time to task failure (TTF), muscle fatigue, movement accuracy, motor output variability, and muscle activity (sEMG). The 240-J dose significantly extended TTF by 26 % (p = 0.032) compared with the sham dose. TTF for the 240-J dose was strongly associated with a decrease in muscle fatigue (R (2) = 0.54, p = 0.024). Our findings show that a 240-J dose of NIR light therapy is efficacious in delaying the onset and extent of muscle fatigue during submaximal isometric positioning tasks. Our findings suggest that NIR light therapy may be used as an ergogenic aid during functional tasks or post-injury rehabilitation.

  4. EFFECTS OF LIGHT WAVELENGTHS AND COHERENCE ON BASIDIOSPORES GERMINATION

    Directory of Open Access Journals (Sweden)

    Natalia Poyedinok

    2015-02-01

    Full Text Available The effects of light wavelengths and coherence on basidiospore germination of Agaricus bisporus, Flammulina velutipes, Ganoderma applanatum, Ganoderma lucidum, Hericium erinaceus, Lentinus edodes and Pleurotus ostreatus have been studied. Short-term low-intensity irradiation by coherent (laser light wavelength 488.0 nm and 632.8 nm at doses 45 and 230 mJ/cm2 has significantly increased the number of germinated basidiospores. It has established that there are differences in the photosensitivity not only between species but also between strains. Spores irradiation by 514.5 nm light has been either neutral or inhibitory. A comparative analysis of basidiospores sensitivity to laser and LED light has also been conducted. To stimulate germination of basidiospores and growth of monokaryons the most suitable solution was to use red coherent and incoherent light of 632.8 nm and 660,0 nm for A. bisporus, G. applanatum and P. ostreatus, red and blue coherent light of 632.8 nm and 488,0 nm for F. velutipes, and both red and blue laser and LED light G. lucidum and H. erinaceus and for L. edodes. No essential difference of a continuous wave mode and intermittent mode light effect at the same doses and wavelength on spore germination were revealed. Light influence has reduced germination time and formation of aerial mycelium on agar medium as compared to the original value and increased the growth rate of monosporous isolates. Characterization of basidiospores photosensitivity and development of environmentally friendly stimulating methods of their germination is important for creating highly effective technologies of mushrooms selection and cultivation.

  5. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  6. Low-Power Photoplethysmogram Acquisition Integrated Circuit with Robust Light Interference Compensation.

    Science.gov (United States)

    Kim, Jongpal; Kim, Jihoon; Ko, Hyoungho

    2015-12-31

    To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG) readout chip is fabricated using a 0.13-μm complementary metal-oxide-semiconductor (CMOS) process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms.

  7. Dose Evaluation of Fractionated Schema and Distance From Tumor to Spinal Cord for Spinal SBRT with Simultaneous Integrated Boost: A Preliminary Study.

    Science.gov (United States)

    Yang, Hao; Cai, Bo-ning; Wang, Xiao-shen; Cong, Xiao-hu; Xu, Wei; Wang, Jin-yuan; Yang, Jun; Xu, Shou-ping; Ju, Zhong-jian; Ma, Lin

    2016-02-23

    BACKGROUND This study investigated and quantified the dosimetric impact of the distance from the tumor to the spinal cord and fractionation schemes for patients who received stereotactic body radiation therapy (SBRT) and hypofractionated simultaneous integrated boost (HF-SIB). MATERIAL AND METHODS Six modified planning target volumes (PTVs) for 5 patients with spinal metastases were created by artificial uniform extension in the region of PTV adjacent spinal cord with a specified minimum tumor to cord distance (0-5 mm). The prescription dose (biologic equivalent dose, BED) was 70 Gy in different fractionation schemes (1, 3, 5, and 10 fractions). For PTV V100, Dmin, D98, D95, and D1, spinal cord dose, conformity index (CI), V30 were measured and compared. RESULTS PTV-to-cord distance influenced PTV V100, Dmin, D98, and D95, and fractionation schemes influenced Dmin and D98, with a significant difference. Distances of ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm from PTV to spinal cord meet dose requirements in 1, 3, 5, and 10 fractionations, respectively. Spinal cord dose, CI, and V30 were not impacted by PTV-to-cord distance and fractionation schemes. CONCLUSIONS Target volume coverage, Dmin, D98, and D95 were directly correlated with distance from the spinal cord for spine SBRT and HF-SIB. Based on our study, ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm distance from PTV to spinal cord meets dose requirements in 1, 3, 5 and 10 fractionations, respectively.

  8. Low dose irradiation facilitates hepatocellular carcinoma genesis involving HULC.

    Science.gov (United States)

    Li, Yuan; Ge, Chang; Feng, Guoxing; Xiao, Huiwen; Dong, Jiali; Zhu, Changchun; Jiang, Mian; Cui, Ming; Fan, Saijun

    2018-03-24

    Irradiation exposure positive correlates with tumor formation, such as breast cancer and lung cancer. However, whether low dose irradiation induces hepatocarcinogenesis and the underlying mechanism remain poorly defined. In the present study, we reported that low dose irradiation facilitated the proliferation of hepatocyte through up-regulating HULC in vitro and in vivo. Low dose irradiation exposure elevated HULC expression level in hepatocyte. Deletion of heightened HULC erased the cells growth accelerated following low dose irradiation exposure. CDKN1, the neighbor gene of HULC, was down-regulated by overexpression of HULC following low dose irradiation exposure via complementary base pairing, resulting in promoting cell cycle process. Thus, our findings provide new insights into the mechanism of low dose irradiation-induced hepatocarcinogenesis through HULC/CDKN1 signaling, and shed light on the potential risk of low dose irradiation for the development of hepatocellular carcinoma in pre-clinical settings. © 2018 Wiley Periodicals, Inc.

  9. Monte Carlo and Lambertian light guide models of the light output from scintillation crystals at megavoltage energies

    International Nuclear Information System (INIS)

    Evans, Philip M.; Mosleh-Shirazi, M. Amin; Harris, Emma J.; Seco, Joao

    2006-01-01

    A new model of the light output from single-crystal scintillators in megavoltage energy x-ray beams has been developed, based on the concept of a Lambertian light guide model (LLG). This was evaluated in comparison with a Monte Carlo (MC) model of optical photon transport, previously developed and reported in the literature, which was used as a gold standard. The LLG model was developed to enable optimization of scintillator detector design. In both models the dose deposition and light propagation were decoupled, the scintillators were cuboids, split into a series of cells as a function of depth, with Lambertian side and entrance faces, and a specular exit face. The signal in a sensor placed 1 and 1000 mm beyond the exit face was calculated. Cesium iodide (CSI) crystals of 1.5 and 3 mm square cross section and 1, 5, and 10 mm depth were modeled. Both models were also used to determine detector signal and optical gain factor as a function of CsI scintillator thickness, from 2 to 10 mm. Results showed a variation in light output with position of dose deposition of a factor of up to approximately 5, for long, thin scintillators (such as 10x1.5x1.5 mm 3 ). For short, fat scintillators (such as 1x3x3 mm 3 ) the light output was more uniform with depth. MC and LLG generally agreed to within 5%. Results for a sensor distance of 1 mm showed an increase in light output the closer the light originates to the exit face, while a distance of 1000 mm showed a decrease in light output the closer the light originates to the exit face. For a sensor distance of 1 mm, the ratio of signal for a 10 mm scintillator to that for a 2 mm scintillator was 1.98, whereas for the 1000 mm distance the ratio was 3.00. The ratio of quantum efficiency (QE) between 10 and 2 mm thicknesses was 4.62. We conclude that these models may be used for detector optimization, with the light guide model suitable for parametric study

  10. Development of a center for light ion therapy and accurate tumor diagnostics at karolinska institutet and hospital

    Science.gov (United States)

    Brahme, Anders; Lind, Bengt K.

    2002-04-01

    Radiation therapy is today in a state of very rapid development with new intensity modulated treatment techniques continuously being developed. This has made intensity modulated electron and photon beams almost as powerful as conventional uniform beam proton therapy. To be able to cure also the most advanced hypoxic and radiation resistant tumors of complex local spread, intensity modulated light ion beams are really the ultimate tool and only slightly more expensive than proton therapy. The aim of the new center for ion therapy and tumor diagnostics in Stockholm is to develop radiobiologically optimized 3-dimensional pencil beam scanning techniques. Beside the "classical" approaches using low ionization density hydrogen ions (protons, but also deuterons and tritium nuclei) and high ionization density carbon ions, two new approaches will be developed. In the first one lithium or beryllium ions, that induce the least detrimental biological effect to normal tissues for a given biological effect in a small volume of the tumor, will be key particles. In the second approach, referred patients will be given a high-dose high-precision "boost" treatment with carbon or oxygen ions during one week preceding the final treatment with conventional radiations in the referring hospital. The rationale behind these approaches is to reduce the high ionization density dose to the normal tissue stroma inside the tumor and to ensure a microscopically uniform dose delivery. The principal idea of the center is to closely integrate ion therapy into the clinical routine and research of a large radiotherapy department. The light ion therapy center will therefore be combined with advanced tumor diagnostics including MR and PET-CT imaging to facilitate efficient high-precision high-dose boost treatment of remitted patients. The possibility to do 3D tumor diagnostics and 3D dose delivery verification with the same PET camera will be the ultimate step in high quality adaptive radiation therapy

  11. Large area flexible lighting foils using distributed bare LED dies on polyester substrates

    NARCIS (Netherlands)

    Ende, D.A. van den; Kusters, R.H.L.; Cauwe, M.; Waal, A. van der; Brand, J. van den

    2013-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and for backlights for flexible displays. Such a large area lighting device can be made by integrating a matrix of closely spaced LEDs on a flexible foil substrate. Preferably, these LEDs are integrated

  12. beta- and gamma-Comparative dose estimates on Eniwetok Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L.

    1982-05-01

    Eniwetok Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Eniwetok Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  13. Maintaining occupational dose ALARA through work management

    International Nuclear Information System (INIS)

    Khan, A. H.

    1999-01-01

    Canadian philosophy in keeping occupational dose ALARA has been to train staff in radiation safety so that they can be fully responsible for participating in minimizing the risks associated with the hazardous work. Senior managers actively promote high standards of performance in dose reduction techniques as a means for integrating ALARA into the operation and maintenance of the station by all personnel. Minimizing radiation dose is accomplished by applying cost effective work management techniques such as Job Safety Analysis, pre-job briefings and establishing and achieving radiation dose goals. Radiation dose goals are used as a management tool for involving all work groups in reducing doses as well as providing a means of assessing the effectiveness of dose reduction actions. ALARA, along with conventional safety, is used as a lever to raise the standard of quality of work and to overall build a safety culture. (author). 4 figs

  14. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  15. Dose budget for exposure control

    International Nuclear Information System (INIS)

    Nair, P.S.

    1999-01-01

    Dose budget is an important management tool to effectively control the collective dose incurred in a nuclear facility. The budget represents a set of yardsticks or guidelines for use in controlling the internal activities, involving radiation exposure in the organisation. The management, through budget can evaluate the radiation protection performance at every level of the organisation where a number of independent functional groups work on routine and non-routine jobs. The discrepancy between the plan and the actual performance is high lighted through the budgets. The organisation may have to change the course of its operation in a particular area or revise its plan with due focus on appropriate protective measures. (author)

  16. Integrating porphyrin nanoparticles into a 2D graphene matrix for free-standing nanohybrid films with enhanced visible-light photocatalytic activity.

    Science.gov (United States)

    Chen, Yingzhi; Huang, Zheng-Hong; Yue, Mengbin; Kang, Feiyu

    2014-01-21

    Organic nanostructures in terms of porphyrin building blocks have shown great potential in visible-light photocatalytic applications because of their optical, electrical, and catalytic properties. Graphenes are known to provide a high-quality two-dimensional (2D) support for inorganic semiconductor nanostructures to increase the adsorption capability of the photocatalysts and an electron-transfer medium with attractive potential to enhance photogenerated charge separation. A combination of porphyrin nanostructures with graphene sheets, particularly in the form of free-standing films, is highly desirable due to its photocatalysing feasibility and convenience. Toward this aim, we demonstrate a facile method to integrate porphyrin (meso-tetra(p-hydroxyphenyl)porphyrin, p-THPP) nanoparticles (NPs) into macroscopic graphene (reduced graphene oxide, rGO) films through vacuum filtration of the co-colloids of graphene oxide (GO) and p-THPP nanoparticles (NPs) followed by gaseous reduction. The obtained p-THPP/rGO nanohybrid film exhibits enhanced visible-light photocatalytic activity compared to each moiety of the hybrid, and this photocatalyst can be easily separated and recycled for successive use with excellent stability. The results show that this facile fabrication of the p-THPP/rGO nanohybrid film makes it available for high-performance optoelectronic applications, as well as for device integration.

  17. Low-Power Photoplethysmogram Acquisition Integrated Circuit with Robust Light Interference Compensation

    Directory of Open Access Journals (Sweden)

    Jongpal Kim

    2015-12-01

    Full Text Available To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG readout chip is fabricated using a 0.13-μm complementary metal–oxide–semiconductor (CMOS process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms.

  18. Plasmonics light modulators

    DEFF Research Database (Denmark)

    Babicheva, Viktoriia; Malureanu, Radu; Lavrinenko, Andrei

    Surface plasmon polaritons (SPPs) are waves propagating at the interface between a metal and a dielectric and, due to their tight confinement, may be used for nanoscale control of the light propagation. Thus, photonic integrated circuits can benefit from devices using SPPs because of their highly...

  19. Integrated Worker Radiation Dose Assessment for the K Basins

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report documents an assessment of the radiation dose workers at the K Basins are expected to receive in the process of removing spent nuclear fuel from the storage basins. The K Basins (K East and K West) are located in the Hanford 100K Area

  20. Effects of photoprotection and reversible inactivation of the yeast Candida guilliermondii, induced by 313 nm light

    International Nuclear Information System (INIS)

    Frajkin, G.Ya.; Pospelov, M.E.; Rubin, L.B.

    1976-01-01

    The results of studies on the effect of near uv light on the yeast Candida guilliermondii are presented. It was shown that certain doses of 313 nm light inactivated the yeast. The detailed affect is shown in the loss of the ability of the cells to form microcolonies and outwardly does not differ from inactivation caused by 254 nm uv. It was concluded that the cell destruction caused by the 313 nm light was not due to damage to DNA. Experiments in which yeast cells were inactivated by 313 nm light before plating on agar and held for some time in a non-nutrient medium permitted observation of recovery of their viability. A difference was shown in the level of repair of yeasts irradiated by 313 nm light (up to 100% recovery) and 254 nm light (60% recovery). The nature of the dependence of the photoprotection on the 313 nm light dose was determined. A decrease in photoprotection was noted, starting with 7x10 -7 einstein/cm 2 , with its complete disappearance upon further dose increase. It is suggested that, in this recovery of the yeast, some other, thus far unknown, mechanism participates. Data were obtained on the survival of yeast irradiated with lethal uv doses. Of special importance, in the authors' opinion, is the fact that, for the photoprotection effect to appear, some time is needed between actions of the 313 and 254 nm lights, which suggests a photoinduced formation in the yeast cells of compounds that protect them from lethal injury

  1. Monolithically Integrated Light Feedback Control Circuit for Blue/UV LED Smart Package

    NARCIS (Netherlands)

    Koladouz Esfahani, Z.; Tohidian, M.; van Zeijl, H.W.; Kolahdouz, Mohammadreza; Zhang, G.Q.

    2017-01-01

    Given the performance decay of high-power light-emitting diode (LED) chips over time and package condition changes, having a reliable output light for sensitive applications is a point of concern. In this study, a light feedback control circuit, including blue-selective photodiodes, for

  2. Lighting for remote viewing systems

    International Nuclear Information System (INIS)

    Draper, J.V.

    1984-01-01

    Scenes viewed by television do not provide the same channels of information for judgment of distances as scenes viewed directly, since television eliminates or degrades several depth perception cues. However, it may be possible to improve depth perception of televised scenes by enhancing the information available through depth cues that are available from lighting. A literature survey and expert opinions were integrated to design a remote lighting arrangement which could enhance depth perception of operators performing remote handling operations. This paper describes the lighting arrangement and discusses some of its advantages and disadvantages

  3. Dose-rate effects of low-dropout voltage regulator at various biases

    International Nuclear Information System (INIS)

    Wang Yiyuan; Zheng Yuzhan; Gao Bo; Chen Rui; Fei Wuxiong; Lu Wu; Ren Diyuan

    2010-01-01

    A low-dropout voltage regulator, LM2941, was irradiated by 60 Co γ-rays at various dose rates and biases for investigating the total dose and dose rate effects. The radiation responses show that the key electrical parameters, including its output and dropout voltage, and the maximum output current, are sensitive to total dose and dose rates, and are significantly degraded at low dose rate and zero bias. The integrated circuits damage change with the dose rates and biases, and the dose-rate effects are relative to its electric field. (authors)

  4. Effects of nano-structured photonic crystals on light extraction enhancement of nitride light-emitting diodes

    International Nuclear Information System (INIS)

    Wu, G.M.; Yen, C.C.; Chien, H.W.; Lu, H.C.; Chang, T.W.; Nee, T.E.

    2011-01-01

    The light extraction efficiency of an InGaN/GaN light-emitting diode (LED) can be enhanced by incorporating nano-structured photonic crystals inside the LED structure. We employed plane wave expansion (PWE) method and finite difference time domain (FDTD) method to reveal the optical confinement effects with the relevant parameters. The results showed that band-gap modulation could increase the efficiency for light extraction at the lattice constant of 200 nm and depth of 200 nm for the 468-nm LED. Focused ion beam (FIB) using Ga created the desired nano-structured patterns. The LED device micro-PL (photoluminescence) results have demonstrated that the triangular photonic crystal arrays could increase the peak illumination intensity by 58%. The peak wavelength remained unchanged. The integrated area under the illumination peak was increased by 75%. As the patterned area ratio was increased to 85%, the peak intensity enhancement was further improved to 91%, and the integrated area was achieved at 106%.

  5. Circuit arrangement for indicating radiation dose rates

    International Nuclear Information System (INIS)

    Virag, Ernoe; Nyari, Istvan; Simon, Jozsef; Styevko, Mihaly; Krampe, Geza.

    1981-01-01

    The invention presents a dosemeter electronic circuit arrangement indicating hazardous dose rate threshold. If the treshold is reached or exceeded, well distinguished sound and light alarm is turned on immidiately. Moreover, certain critical levels can also be indicated by making the intermittent singalling continuous. (A.L.)

  6. Integrated Instrumentation for Light-Emitting Polymers Development

    National Research Council Canada - National Science Library

    Jen, Alex

    2000-01-01

    The major objective of this project is to develop an integrated instrumentation that combines the capability of performing spin coating of uniform polymer thin films under an oxygen and moisture free...

  7. Photochemical eradication of methicillin-resistant Staphylococcus aureus by blue light activation of riboflavin.

    Science.gov (United States)

    Makdoumi, Karim; Goodrich, Ray; Bäckman, Anders

    2017-08-01

    To compare elimination of methicillin-resistant Staphylococcus aureus (MRSA) by exposure of blue light alone and with riboflavin. A reference strain of MRSA was cultured and diluted in PBS with and without riboflavin (0.01%). Fifteen microlitre was added on a microscope slide, creating a fluid layer with a thickness of around 400 microns. Both of the bacterial suspensions were exposed to blue light, and the effect between exposure with and without riboflavin was compared. Evaluation involved two different wavelengths (412 and 450 nm) of blue light with a lower (5.4 J/cm 2 ) and higher dose (approximately 28.5 J/cm 2 ). The effect of 412 nm light was also evaluated for a thicker fluid layer (1.17 mm). After exposure, colony-forming units (CFUs) were determined for each solution. All measurements were repeated eight times. The reductions in bacteria were similar for both wavelengths. With riboflavin, a statistically significant elimination was observed for both 412 and 450 nm (p riboflavin than without it. Using the higher dose, CFU reduction was 99% and 98%, respectively, for 412 and 450 nm light. The bactericidal efficacy was high also in the deeper fluid layer (93%, higher dose). Riboflavin enhanced the antibacterial effect on the exposed MRSA strain of blue light for both 412 and 450 nm blue light. This indicates that blue light could be considered for possible implementation in deep corneal infections. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Scintillator device using a combined organic-inorganic scintillator as dose ratemeter

    International Nuclear Information System (INIS)

    Kolb, W.; Lauterbach, U.

    1974-01-01

    The dose ratemeter independent of energy in the energy region 17 keV to 3 MeV consists of an organic and an inorganic scintillator. The organic scintillation material of an anthracene monocrystal is surrounded by ZnS surface coating. The coating thickness of the inorganic scintillator ZnS is measured in such a manner for gamma and X-radiation below 100 keV that the light produced due to the incident radiation compensates for the decrease of light produced in the organic scintillator. The whole energy and dose rate region of interest for radiation protection can thus be measured with a detector volume of 135 cm 3 . (DG) [de

  9. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  10. Analysis of offsite dose calculation methodology for a nuclear power reactor

    International Nuclear Information System (INIS)

    Moser, D.M.

    1995-01-01

    This technical study reviews the methodology for calculating offsite dose estimates as described in the offsite dose calculation manual (ODCM) for Pennsylvania Power and Light - Susquehanna Steam Electric Station (SSES). An evaluation of the SSES ODCM dose assessment methodology indicates that it conforms with methodology accepted by the US Nuclear Regulatory Commission (NRC). Using 1993 SSES effluent data, dose estimates are calculated according to SSES ODCM methodology and compared to the dose estimates calculated according to SSES ODCM and the computer model used to produce the reported 1993 dose estimates. The 1993 SSES dose estimates are based on the axioms of Publication 2 of the International Commission of Radiological Protection (ICRP). SSES Dose estimates based on the axioms of ICRP Publication 26 and 30 reveal the total body estimates to be the most affected

  11. Extending the dose range: Probing deep traps in quartz with 3.06 eV photons

    DEFF Research Database (Denmark)

    Jain, Mayank

    2009-01-01

    stimulation. Although, the fast OSL component is measured with similar efficiency by blue and violet lights, the slower OSL components (especially S3) are measured relatively more efficiently with the latter. New insight into the origins of quartz luminescence is presented through a comparison of violet......This article demonstrates that violet (405 nm) stimulated luminescence (VSL) signal from quartz contains contribution from deep traps that are otherwise not accessible with blue light (470 nm). Additionally, it also contains the typical fast and slow components observed with the blue light...... and blue lights stimulation, and thermal stimulations. Finally, it is shown that the deep traps probed through violet light stimulation have potential for increasing the dose measurement/dating range using quartz. The post-blue VSL signal allows easy, precise measurement of dose up to at least 1 kGy in our...

  12. Integrated single- and two-photon light sheet microscopy using accelerating beams

    DEFF Research Database (Denmark)

    Piksarv, Peeter; Marti, Dominik; Le, Tuan

    2017-01-01

    We demonstrate the first light sheet microscope using propagation invariant, accelerating Airy beams that operates both in single- and two-photon modes. The use of the Airy beam permits us to develop an ultra compact, high resolution light sheet system without beam scanning. In two-photon mode......, an increase in the field of view over the use of a standard Gaussian beam by a factor of six is demonstrated. This implementation for light sheet microscopy opens up new possibilities across a wide range of biomedical applications, especially for the study of neuronal processes....

  13. FAKE STAR FORMATION BURSTS: BLUE HORIZONTAL BRANCH STARS MASQUERADE AS YOUNG MASSIVE STARS IN OPTICAL INTEGRATED LIGHT SPECTROSCOPY

    International Nuclear Information System (INIS)

    Ocvirk, P.

    2010-01-01

    Model color-magnitude diagrams of low-metallicity globular clusters (GCs) usually show a deficit of hot evolved stars with respect to observations. We investigate quantitatively the impact of such modeling inaccuracies on the significance of star formation history reconstructions obtained from optical integrated spectra. To do so, we analyze the sample of spectra of galactic globular clusters of Schiavon et al. with STECKMAP (Ocvirk et al.), and the stellar population models of Vazdekis et al. and Bruzual and Charlot, and focus on the reconstructed stellar age distributions. First, we show that background/foreground contamination correlates with E(B - V), which allows us to define a clean subsample of uncontaminated GCs, on the basis of an E(B - V) filtering. We then identify a 'confusion zone' where fake young bursts of star formation pop up in the star formation history although the observed population is genuinely old. These artifacts appear for 70%-100% of cases depending on the population model used, and contribute up to 12% of the light in the optical. Their correlation with the horizontal branch (HB) ratio indicates that the confusion is driven by HB morphology: red HB clusters are well fitted by old stellar population models while those with a blue HB require an additional hot component. The confusion zone extends over [Fe/H] = [ - 2, - 1.2], although we lack the data to probe extreme high and low metallicity regimes. As a consequence, any young starburst superimposed on an old stellar population in this metallicity range could be regarded as a modeling artifact, if it weighs less than 12% of the optical light, and if no emission lines typical of an H II region are present. This work also provides a practical method for constraining HB morphology from high signal to noise integrated light spectroscopy in the optical. This will allow post-asymptotic giant branch evolution studies in a range of environments and at distances where resolving stellar populations

  14. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  15. Suitability of sterin dose indicators for control of certain food irradiation processes

    International Nuclear Information System (INIS)

    Sattar, Abdus; Ahmad, Anwar; Iqbal, Mohammad Zafar

    1999-01-01

    Sterin indicator, a new label dosimeter was evaluated for reliability and suitability as a device for discriminating and monitoring radiation treatment. Two versions, Sterin-125 and Sterin-300 were irradiated with gamma rays at dose ranges of 75-175 Gy and 200-400 Gy respectively. The irradiated samples were evaluated subjectively using Multiple Comparison Difference technique and their stability was tested under dark and differing light and temperature conditions. The results showed that these Sterin labels are generally reliable and useful but are affected by doses lower than designated threshold and by extended exposure to light sources

  16. Calculation of the primary dose in the absence of electronic equilibrium

    International Nuclear Information System (INIS)

    Petrov, D.E.

    1995-01-01

    In a multilayered media at points close to the boundary of any two layers of different electronic densities, the absorbed dose due to primary radiation, can be estimated by means of secondary electrons. Assuming monoenergetic megavoltage photons incident on a two layered media, the Compton effect is a predominant mode of interaction, the primary dose is due to the electrons set into motion from the first interaction. The dose is divided into components from the upper and lower layers. The beam width must be large enough so that all electrons scattered at some angle could pass through detector point. General expression for the dose is a product of the initial photon flux at some depth, the Klein-Nisha cross section, and the ionizational mass stopping power integrated over azimuthal angle. The factor taking into account real geometry is out of the sign of integral. The latter depends only on the distance between the interface and detector for the given consequence of layers. At the interface there is a peak or drop of the dose determined by the ratio of the stopping powers under the sign of the integral. At points beyond the interface the dose decreases or increases up to electronic equilibrium region where the absorbed dose and the kerma are parallel to each other. The peak width at the base is determined by the free range of the electron with the maximum possible energy after the Compton scattering

  17. The national dose registry of Canada

    International Nuclear Information System (INIS)

    1982-04-01

    In 1951, when the National Dosimetry Service was established by the Department of National Health and Welfare, a system of centralized records was created as an integral part of the new service. Over the last few years the dose record system has expanded in size and content, and improvements have been made in the physical methods of record storage. In addition to the 250 000 individual dose records from the National Dosimetry Service, the National Dose Registry now includes internal tritium and external doses from nuclear generating stations, and radon daughter exposures submitted by uranium mining companies. With the increase in the use of radiation in the medical, industrial and research fields, it is becoming more important to have a comprehensive and readily accessible centralized record system. The Canadian National Dose Registry is particularly suited for continuing health risk studies of radiation workers and provides a base for future epidemiological studies

  18. The Direct Lighting Computation in Global Illumination Methods

    Science.gov (United States)

    Wang, Changyaw Allen

    1994-01-01

    Creating realistic images is a computationally expensive process, but it is very important for applications such as interior design, product design, education, virtual reality, and movie special effects. To generate realistic images, state-of-art rendering techniques are employed to simulate global illumination, which accounts for the interreflection of light among objects. In this document, we formalize the global illumination problem into a eight -dimensional integral and discuss various methods that can accelerate the process of approximating this integral. We focus on the direct lighting computation, which accounts for the light reaching the viewer from the emitting sources after exactly one reflection, Monte Carlo sampling methods, and light source simplification. Results include a new sample generation method, a framework for the prediction of the total number of samples used in a solution, and a generalized Monte Carlo approach for computing the direct lighting from an environment which for the first time makes ray tracing feasible for highly complex environments.

  19. GaN-based integrated photonics chip with suspended LED and waveguide

    Science.gov (United States)

    Li, Xin; Wang, Yongjin; Hane, Kazuhiro; Shi, Zheng; Yan, Jiang

    2018-05-01

    We propose a GaN-based integrated photonics chip with suspended LED and straight waveguide with different geometric parameters. The integrated photonics chip is prepared by double-side process. Light transmission performance of the integrated chip verse current is quantitatively analyzed by capturing light transmitted to waveguide tip and BPM (beam propagation method) simulation. Reduction of the waveguide width from 8 μm to 4 μm results in an over linear reduction of the light output power while a doubling of the length from 250 μm to 500 μm only results in under linear decrease of the output power. Free-space data transmission with 80 Mbps random binary sequence of the integrated chip is capable of achieving high speed data transmission via visible light. This study provides a potential approach for GaN-based integrated photonics chip as micro light source and passive optical device in VLC (visible light communication).

  20. A repository released-dose model for the evaluation of long-lived fission product transmutation effectiveness

    International Nuclear Information System (INIS)

    Davidson, J.W.

    1995-01-01

    A methodology has been developed to quantify the total integrated dose due to a radionuclide species i emplaced in a geologic repository; the focus is on the seven long-lived fission products (LLFPs). The methodology assumes continuous exposure water contaminated with species i at the accessible environment (i.e., just beyond the geologic barrier afforded by the geologic repository). The dose integration is performed out to a reference post-release time. The integrated dose is a function of the total initial inventory of radionuclide i the repository, the time at which complete and instantaneous failure of the engineered barrier (e.g., waste canister) in, a geologic repository occurs, the fractional dissolution rate (from waste solid form) of radionuclide i in ground water, the ground water travel time to the accessible environment, the retardation factor (sorption on the geologic media) for radionuclide i, the time after radionuclide begins to enter the biosphere. In order to assess relative dose, the ratio of total integrated dose to that for a reference LLFP species j (e.g., 99 Tc) was defined. This ratio is a measure of the relative benefit of transmutation of other LLFPs compared to 99 Tc. This methodology was further developed in order to quantify the integrated dose reduction per neutron utilized for LLFP transmutation in accelerator-driven transmutation technologies (ADTT). This measure of effectiveness is a function of the integrated dose due to LLFP species i, the number of total captures in LLFP species i chain per LLFP nuclide fed to the chain at equilibrium, and the number of total captures in related transmutation product (TP) chains per capture in the LLFP species i chain. To assess relative transmutation effectiveness, the ratio of integrated dose reduction per neutron utilization to that for a reference LLFP species j (e.g., 99 Tc) was defined. This relative measure of effectiveness was evaluated LLFP transmutation strategy

  1. Flow velocity and light level drive non-linear response of seagrass

    NARCIS (Netherlands)

    Villazán, B.; Brun, F.G.; Moreno-Marín, F; Bouma, T.J.; Vergara, J.J.

    2016-01-01

    We investigated the interactive effects of light (low and high light doses) and flowvelocity (low, medium and high levels) under NH4+ enriched conditions on dynamic and morphologicalvariables of Zostera noltei plants in a 5 wk flume experiment. Our results showed a nonlinearresponse of Z. noltei in

  2. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2005-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  3. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2000-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  4. Electrically-driven GHz range ultrafast graphene light emitter (Conference Presentation)

    Science.gov (United States)

    Kim, Youngduck; Gao, Yuanda; Shiue, Ren-Jye; Wang, Lei; Aslan, Ozgur Burak; Kim, Hyungsik; Nemilentsau, Andrei M.; Low, Tony; Taniguchi, Takashi; Watanabe, Kenji; Bae, Myung-Ho; Heinz, Tony F.; Englund, Dirk R.; Hone, James

    2017-02-01

    Ultrafast electrically driven light emitter is a critical component in the development of the high bandwidth free-space and on-chip optical communications. Traditional semiconductor based light sources for integration to photonic platform have therefore been heavily studied over the past decades. However, there are still challenges such as absence of monolithic on-chip light sources with high bandwidth density, large-scale integration, low-cost, small foot print, and complementary metal-oxide-semiconductor (CMOS) technology compatibility. Here, we demonstrate the first electrically driven ultrafast graphene light emitter that operate up to 10 GHz bandwidth and broadband range (400 1600 nm), which are possible due to the strong coupling of charge carriers in graphene and surface optical phonons in hBN allow the ultrafast energy and heat transfer. In addition, incorporation of atomically thin hexagonal boron nitride (hBN) encapsulation layers enable the stable and practical high performance even under the ambient condition. Therefore, electrically driven ultrafast graphene light emitters paves the way towards the realization of ultrahigh bandwidth density photonic integrated circuits and efficient optical communications networks.

  5. Manual of dose evaluation from atmospheric releases

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Abrol, V [Health Physics Division, Bhabha Atomic Research Centre, Bombay (India)

    1978-07-01

    The problem of dose evaluation from atmospheric releases is reduced to simple arithmetic by giving tables of concentrations and time integrated concentrations for instantaneous plumes and long time (1 year), sector averaged plumes for distances upto 10 km, effective release heights of upto 200 m and the six Pasquill stability classes. Correction factors for decay, depletion due to deposition and rainout are also given. Inhalation doses, immersion doses and contamination levels can be obtained from these by using multiplicative factors tabulated for various isotopes of significance. Tables of external gamma doses from plume are given separately for various gamma energies. Tables are also given to evaluate external beta and gamma dose rates from contaminated surfaces. The manual also discusses the basic diffusion model relevant to the problem. (author)

  6. Integrability in heavy quark effective theory

    Science.gov (United States)

    Braun, Vladimir M.; Ji, Yao; Manashov, Alexander N.

    2018-06-01

    It was found that renormalization group equations in the heavy-quark effective theory (HQET) for the operators involving one effective heavy quark and light degrees of freedom are completely integrable in some cases and are related to spin chain models with the Hamiltonian commuting with the nondiagonal entry C( u) of the monodromy matrix. In this work we provide a more complete mathematical treatment of such spin chains in the QISM framework. We also discuss the relation of integrable models that appear in the HQET context with the large-spin limit of integrable models in QCD with light quarks. We find that the conserved charges and the "ground state" wave functions in HQET models can be obtained from the light-quark counterparts in a certain scaling limit.

  7. GLOBULAR CLUSTER ABUNDANCES FROM HIGH-RESOLUTION, INTEGRATED-LIGHT SPECTROSCOPY. IV. THE LARGE MAGELLANIC CLOUD: α, Fe-PEAK, LIGHT, AND HEAVY ELEMENTS

    International Nuclear Information System (INIS)

    Colucci, Janet E.; Bernstein, Rebecca A.; Cameron, Scott A.; McWilliam, Andrew

    2012-01-01

    We present detailed chemical abundances in eight clusters in the Large Magellanic Cloud (LMC). We measure abundances of 22 elements for clusters spanning a range in age of 0.05-12 Gyr, providing a comprehensive picture of the chemical enrichment and star formation history of the LMC. The abundances were obtained from individual absorption lines using a new method for analysis of high-resolution (R ∼ 25,000), integrated-light (IL) spectra of star clusters. This method was developed and presented in Papers I, II, and III of this series. In this paper, we develop an additional IL χ 2 -minimization spectral synthesis technique to facilitate measurement of weak (∼15 mÅ) spectral lines and abundances in low signal-to-noise ratio data (S/N ∼ 30). Additionally, we supplement the IL abundance measurements with detailed abundances that we measure for individual stars in the youngest clusters (age +0.5) and increases with decreasing age, indicating a strong contribution of low-metallicity asymptotic giant branch star ejecta to the interstellar medium throughout the later history of the LMC. We also find a correlation of IL Na and Al abundances with cluster mass in the sense that more massive, older clusters are enriched in the light elements Na and Al with respect to Fe, which implies that these clusters harbor star-to-star abundance variations as is common in the MW. Lower mass, intermediate-age, and young clusters have Na and Al abundances that are lower and more consistent with LMC field stars. Our results can be used to constrain both future chemical evolution models for the LMC and theories of globular cluster formation.

  8. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  9. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  10. Efficacy of 670 nm Light Therapy to Protect against Photoreceptor Cell Death Is Dependent on the Severity of Damage

    Directory of Open Access Journals (Sweden)

    Joshua A. Chu-Tan

    2016-01-01

    Full Text Available Photobiomodulation at a wavelength of 670 nm has been shown to be effective in preventing photoreceptor cell death in the retina. We treated Sprague-Dawley (SD rats with varying doses of 670 nm light (9; 18; 36; 90 J/cm2 before exposing them to different intensities of damaging white light (750; 1000; 1500 lux. 670 nm light exhibited a biphasic response in its amelioration of cell death in light-induced degeneration in vivo. Lower light damage intensities required lower doses of 670 nm light to reduce TUNEL cell death. At higher damage intensities, the highest dose of 670 nm light showed protection. In vitro, the Seahorse XFe96 Extracellular Flux Analyzer revealed that 670 nm light directly influences mitochondrial metabolism by increasing the spare respiratory capacity of mitochondria in 661 W photoreceptor-like cells in light damaged conditions. Our findings further support the use of 670 nm light as an effective treatment against retinal degeneration as well as shedding light on the mechanism of protection through the increase of the mitochondrial spare respiratory capacity.

  11. Endoscopic hyperspectral imaging: light guide optimization for spectral light source

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2018-02-01

    Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.

  12. Updated radiological dose assessment of Bikini and Eneu Islands at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Stuart, M.L.; Thompson, S.E.; Conrado, C.L.; Stoker, A.C.

    1982-01-01

    This report is part of a continuing effort to refine dose assessments for resettlement options at Bikini Atoll. Radionuclide concentration data developed at Bikini Atoll since 1977 have been used in conjunction with recent dietary information and current dose models to develop the annual dose rate and 30- and 50-y integral doses presented here for Bikini and Eneu Island living patterns. The terrestrial food chain is the most significant exposure pathway--it contributes more than 50% of the total dose--and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation. Cesium-137 produces more than 85% of the predicted dose; 90 Sr is the second most significant radionuclide; 60 Co contributes to the external gamma exposure in varying degrees, but is a small part of the total predicted dose; the transuranic radionuclides contribute a small portion of the total predicted lung and bone doses but do present a long-term source of exposure. Maximum annual dose rates for Bikini Island are about 1 rem/y for the whole body and bone marrow when imported foods are available and about 1.9 rem/y when imports are unavailable. Maximum annual dose rates for Eneu Island when imports are available are 130 mrem/y for the whole body and 136 mrem/y for bone marrow. Similar doses when imported foods are unavailable are 245 and 263 mrem/y, respectively. The 30-y integral doses for Bikini Island are about 23 rem for whole body and bone marrow when imported foods are available and more than 40 rem when imports are unavailable. The Eneu Island 30-y integral doses for whole body and bone marrow are about 3 rem when imports are available and 5.5 and 6.1 rem, respectively, when imports are unavailable. Doses from living patterns involving some combination of Bikini and Eneu Islands fall between the doses listed above for each island separately

  13. Sustainability Instruction in High Doses: Results From Incorporation of Multiple InTeGrate Modules Into an Environmental Science Class

    Science.gov (United States)

    Rademacher, L. K.

    2017-12-01

    The Interdisciplinary Teaching about Earth for a Sustainable Future (InTeGrate) community has developed extensive courses and modules designed for broad adoption into geoscience classrooms in diverse environments. I participated in a three-semester research project designed to test the efficacy of incorporating "high doses" (minimum 3 modules or 18 class periods) of InTeGrate materials into a course, in my case, an introductory environmental science class. InTeGrate materials were developed by groups of instructors from a range of institutions across the US. These materials include an emphasis on systems thinking, interdisciplinary approaches, and sustainability, and those themes are woven throughout the modules. The three semesters included a control in which no InTeGrate materials were used, a pilot in which InTeGrate materials were tested, and a treatment semesters in which tested materials were modified as needed and fully implemented into the course. Data were collected each semester on student attitudes using the InTeGrate Attitudinal Instrument (pre and post), a subset of Geoscience Literacy Exam questions (pre and post), and a series of assessments and essay exam questions (post only). Although results suggest that learning gains were mixed, changes in attitudes pre- and post-instruction were substantial. Changes in attitudes regarding the importance of sustainable employers, the frequency of self-reported individual sustainable actions, and motivation level for creating a sustainable society were observed in the control and treatment semesters, with the treatment semester showing the greatest gains. Importantly, one of the biggest differences between the control and treatment semesters is the reported impact that the course had on influencing students' sustainable behaviors. The treatment semester course impacted students' sustainable behaviors far more than the control semester.

  14. Integration profile and safety of an adenovirus hybrid-vector utilizing hyperactive sleeping beauty transposase for somatic integration.

    Directory of Open Access Journals (Sweden)

    Wenli Zhang

    Full Text Available We recently developed adenovirus/transposase hybrid-vectors utilizing the previously described hyperactive Sleeping Beauty (SB transposase HSB5 for somatic integration and we could show stabilized transgene expression in mice and a canine model for hemophilia B. However, the safety profile of these hybrid-vectors with respect to vector dose and genotoxicity remains to be investigated. Herein, we evaluated this hybrid-vector system in C57Bl/6 mice with escalating vector dose settings. We found that in all mice which received the hyperactive SB transposase, transgene expression levels were stabilized in a dose-dependent manner and that the highest vector dose was accompanied by fatalities in mice. To analyze potential genotoxic side-effects due to somatic integration into host chromosomes, we performed a genome-wide integration site analysis using linker-mediated PCR (LM-PCR and linear amplification-mediated PCR (LAM-PCR. Analysis of genomic DNA samples obtained from HSB5 treated female and male mice revealed a total of 1327 unique transposition events. Overall the chromosomal distribution pattern was close-to-random and we observed a random integration profile with respect to integration into gene and non-gene areas. Notably, when using the LM-PCR protocol, 27 extra-chromosomal integration events were identified, most likely caused by transposon excision and subsequent transposition into the delivered adenoviral vector genome. In total, this study provides a careful evaluation of the safety profile of adenovirus/Sleeping Beauty transposase hybrid-vectors. The obtained information will be useful when designing future preclinical studies utilizing hybrid-vectors in small and large animal models.

  15. Large-area OLED lightings and their applications

    International Nuclear Information System (INIS)

    Park, J W; Shin, D C; Park, S H

    2011-01-01

    In this paper, we review the key issues related to the fabrication of large-area organic light-emitting devices (OLEDs) for lighting applications. We discuss the origin of a short-circuit problem, luminance non-uniformity, hot spot, efficiency reduction (power loss), and heat generation and present the way of suppressing them. We also introduce three different application areas of large-area OLED lighting panels. They can be integrated with a solar cell for power recycling or inorganic LEDs for emotional lightings. The feasibility of using OLEDs for the application of visible-light communications is also reviewed

  16. Flashing light in microalgae biotechnology.

    Science.gov (United States)

    Abu-Ghosh, Said; Fixler, Dror; Dubinsky, Zvy; Iluz, David

    2016-03-01

    Flashing light can enhance photosynthesis and improve the quality and quantity of microalgal biomass, as it can increase the products of interest by magnitudes. Therefore, the integration of flashing light effect into microalgal cultivation systems should be considered. However, microalgae require a balanced mix of the light/dark cycle for higher growth rates, and respond to light intensity differently according to the pigments acquired or lost during the growth. This review highlights recently published results on flashing light effect on microalgae and its applications in biotechnology, as well as the recently developed bioreactors designed to fulfill this effect. It also discusses how this knowledge can be applied in selecting the optimal light frequencies and intensities with specific technical properties for increasing biomass production and/or the yield of the chemicals of interest by microalgae belonging to different genera. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.; Dorsey, Anthony T.; Hagedorn, Brenda M.

    2000-01-01

    Purpose: To determine the magnitude of the differences between urethral dose-volume, dose-area, and dose-length histograms (DVH, DAH, and DLH, respectively, or DgH generically). Methods and Materials: Six consecutive iodine-125 ( 125 I) patients and 6 consecutive palladium-103 ( 103 Pd) patients implanted via a modified uniform planning approach were evaluated with day 0 computed tomography (CT)-based dosimetry. The urethra was identified by the presence of a urinary catheter and was hand drawn on the CT images with a mean radius of 3.3 ± 0.7 mm. A 0.1-mm calculation matrix was employed for the urethral volume and surface analysis, and urethral dose points were placed at the centroid of the urethra on each 5-mm CT slice. Results: Although individual patient DLHs were step-like, due to the sparseness of the data points, the composite urethral DLH, DAH, and DVHs were qualitatively similar. The DAH curve delivered more radiation than the other two curves at all doses greater than 90% of the prescribed minimum peripheral dose (mPD) to the prostate. In addition, the DVH curve was consistently higher than the DLH curve at most points throughout that range. Differences between the DgH curves were analyzed by integrating the difference curves between 0 and 200% of the mPD. The area-length, area-volume, and volume-length difference curves integrated in the ratio of 3:2:1. The differences were most pronounced near the inflection point of the DgH curves with mean A 125 , V 125 , and L 125 values of 36.6%, 31.4%, and 23.0%, respectively, of the urethra. Quantifiers of urethral hot spots such as D 10 , defined as the minimal dose delivered to the hottest 10% of the urethra, followed the same ranking: area analysis indicated the highest dose and length analysis, the lowest dose. D 10 was 148% and 136% of mPD for area and length evaluations, respectively. Comparing the two isotopes in terms of the amount of urethra receiving a given dose, 103 Pd implants were significantly

  18. A fast radiation-to-coherent light converter

    International Nuclear Information System (INIS)

    Wang, C.L.; Flatley, J.E.; Stewart, P.H.

    1988-01-01

    We have developed a radiation-to-coherent light converter (RCLC) with a monolithically integrated semiconductor chip that consists of a chromium-doped GaAs photoconductor detector modulates the laser diode, which has been biased above the lasing threshold, thus converting a radiation pulse to an electric pulse and then to a light pulse. The laser pulse is then transmitted to a fast recorder through a high-bandwidth optical fiber. In the absence of a single-step x-ray pumped laser, our converter appears to be the first integrated device that can efficiently convert x-ray flux into coherent light. This device has been tested successfully with the 50-ps electron beams of a 17-MeV linear accelerator and with 50-ns x-ray pulses from a Z-pinch plasma source. 2 refs., 9 figs

  19. Continuous-flow system and monitoring tools for the dielectrophoretic integration of nanowires in light sensor arrays.

    Science.gov (United States)

    Marín, A García; Núñez, C García; Rodríguez, P; Shen, G; Kim, S M; Kung, P; Piqueras, J; Pau, J L

    2015-03-20

    Although nanowires (NWs) may improve the performance of many optoelectronic devices such as light emitters and photodetectors, the mass commercialization of these devices is limited by the difficult task of finding reliable and reproducible methods to integrate the NWs on foreign substrates. This work shows the fabrication of zinc oxide NWs photodetectors on conventional glass using transparent conductive electrodes to effectively integrate the NWs at specific locations by dielectrophoresis (DEP). The paper describes the careful preparation of NW dispersions by sedimentation and the dielectrophoretic alignment of NWs in a home-made system. This system includes an impedance technique for the assessment of the alignment quality in real time. Following this procedure, ultraviolet photodetectors based on the electrical contacts formed by the DEP process on the transparent electrodes are fabricated. This cost-effective mean of contacting NWs enables front-and back-illumination operation modes, the latter eliminating shadowing effects caused by the deposition of metals. The electro-optical characterization of the devices shows uniform responsivities in the order of 106 A W(-1) below 390 nm under both modes, as well as, time responses of a few seconds.

  20. Lighting for remote viewing systems

    International Nuclear Information System (INIS)

    Draper, J.V.

    1984-01-01

    Scenes viewed by television do not provide the same channels of information for judgment of distances as scenes viewed directly, since television eliminates or degrades several depth perception cues. However, it may be possible to improve depth perception of televised scenes by enhancing the information available through depth cues that are available from lighting. A literature survey and expert opinions were integrated to design a remote lighting arrangement which could enhance depth perception of operators performing remote handling operations. This paper describes the lighting arrangement and discusses some of its advantages and disadvantages. 10 references, 2 figures

  1. Traffic Light Detection at Night

    DEFF Research Database (Denmark)

    Jensen, Morten Bornø; Philipsen, Mark Philip; Bahnsen, Chris

    2015-01-01

    Traffic light recognition (TLR) is an integral part of any in- telligent vehicle, it must function both at day and at night. However, the majority of TLR research is focused on day-time scenarios. In this paper we will focus on detection of traffic lights at night and evalu- ate the performance...... of three detectors based on heuristic models and one learning-based detector. Evaluation is done on night-time data from the public LISA Traffic Light Dataset. The learning-based detector out- performs the model-based detectors in both precision and recall. The learning-based detector achieves an average...

  2. Lighting for remote viewing systems

    International Nuclear Information System (INIS)

    Draper, J.V.

    1984-01-01

    Scenes viewed by television do not provide the same channels of information for judgement of distances as scenes viewed directly, since television eliminates or degrades several depth perception cues. However, it may be possible to improve depth perception of televised scenes by enhancing the information available through depth cues that are available from lighting. A literature survey and expert opinions were integrated to design a remote lighting arrangement which could enhance depth perception of operators performing remote handling operations. This paper describes the lighting arrangement and discusses some of its advantages and disadvantages. 10 references, 2 figures

  3. Lighting for remote viewing systems

    Energy Technology Data Exchange (ETDEWEB)

    Draper, J.V.

    1984-01-01

    Scenes viewed by television do not provide the same channels of information for judgment of distances as scenes viewed directly, since television eliminates or degrades several depth perception cues. However, it may be possible to improve depth perception of televised scenes by enhancing the information available through depth cues that are available from lighting. A literature survey and expert opinions were integrated to design a remote lighting arrangement which could enhance depth perception of operators performing remote handling operations. This paper describes the lighting arrangement and discusses some of its advantages and disadvantages. 10 references, 2 figures.

  4. Lighting for remote viewing systems

    Energy Technology Data Exchange (ETDEWEB)

    Draper, J.V.

    1984-01-01

    Scenes viewed by television do not provide the same channels of information for judgement of distances as scenes viewed directly, since television eliminates or degrades several depth perception cues. However, it may be possible to improve depth perception of televised scenes by enhancing the information available through depth cues that are available from lighting. A literature survey and expert opinions were integrated to design a remote lighting arrangement which could enhance depth perception of operators performing remote handling operations. This paper describes the lighting arrangement and discusses some of its advantages and disadvantages. 10 references, 2 figures.

  5. An updated dose assessment for Rongelap Island

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Bogen, K.T.

    1994-07-01

    We have updated the radiological dose assessment for Rongelap Island at Rongelap Atoll using data generated from field trips to the atoll during 1986 through 1993. The data base used for this dose assessment is ten fold greater than that available for the 1982 assessment. Details of each data base are presented along with details about the methods used to calculate the dose from each exposure pathway. The doses are calculated for a resettlement date of January 1, 1995. The maximum annual effective dose is 0.26 mSv y{sup {minus}1} (26 mrem y{sup {minus}1}). The estimated 30-, 50-, and 70-y integral effective doses are 0.0059 Sv (0.59 rem), 0.0082 Sv (0.82 rem), and 0.0097 Sv (0.97 rem), respectively. More than 95% of these estimated doses are due to 137-Cesium ({sup 137}Cs). About 1.5% of the estimated dose is contributed by 90-Strontium ({sup 90}Sr), and about the same amount each by 239+240-Plutonium ({sup 239+240}PU), and 241-Americium ({sup 241}Am).

  6. Development of a compact light weight DELRAD probe and its integration with UAV NETRA for aerial radiation surveillance

    International Nuclear Information System (INIS)

    Prasad, Mahaveer; Yadav, Ashok Kumar; Gupta, D.K.; Bhatnagar, Vivek; Singh, Chiman; Mishrilal

    2018-01-01

    The DEfence Laboratory RAdiation Detector - 'DELRAD' is an indigenously developed Hybrid Micro Circuit Module employing Si PIN diodes for detection of gamma radiation. Using this as a detector, the 'DELRAD Probe' has been designed and developed specifically for the UAV, NETRA for aerial surveillance of the nuclear affected areas. The critical requirement of very light weight radiation sensor as payload (<50gm) for the UAV NETRA is met by designing this Probe weighing approx. 40gm. The sensor is capable of measuring gamma radiation levels from 1mR/h to 1000R/h. The Probe has been tested, calibrated and integrated with the UAV NETRA. In addition to this, the radiation testing during flight of UAV NETRA integrated with DELRAD probe has also been carried out and results have been recorded. The work carried out proves the capability of Defence Laboratory, Jodhpur, (DRDO) in the area of 'Aerial Surveillance of Nuclear Radiation Affected Area' using Unmanned Aerial Vehicles (UAVs)

  7. Silicon integrated circuit process

    International Nuclear Information System (INIS)

    Lee, Jong Duck

    1985-12-01

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  8. Silicon integrated circuit process

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Duck

    1985-12-15

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  9. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  10. Calculation of integrated biological response in brachytherapy

    International Nuclear Information System (INIS)

    Dale, Roger G.; Coles, Ian P.; Deehan, Charles; O'Donoghue, Joseph A.

    1997-01-01

    Purpose: To present analytical methods for calculating or estimating the integrated biological response in brachytherapy applications, and which allow for the presence of dose gradients. Methods and Materials: The approach uses linear-quadratic (LQ) formulations to identify an equivalent biologically effective dose (BED eq ) which, if applied to a specified tissue volume, would produce the same biological effect as that achieved by a given brachytherapy application. For simple geometrical cases, BED multiplying factors have been derived which allow the equivalent BED for tumors to be estimated from a single BED value calculated at a dose reference point. For more complex brachytherapy applications a voxel-by-voxel determination of the equivalent BED will be more accurate. Equations are derived which when incorporated into brachytherapy software would facilitate such a process. Results: At both high and low dose rates, the BEDs calculated at the dose reference point are shown to be lower than the true values by an amount which depends primarily on the magnitude of the prescribed dose; the BED multiplying factors are higher for smaller prescribed doses. The multiplying factors are less dependent on the assumed radiobiological parameters. In most clinical applications involving multiple sources, particularly those in multiplanar arrays, the multiplying factors are likely to be smaller than those derived here for single sources. The overall suggestion is that the radiobiological consequences of dose gradients in well-designed brachytherapy treatments, although important, may be less significant than is sometimes supposed. The modeling exercise also demonstrates that the integrated biological effect associated with fractionated high-dose-rate (FHDR) brachytherapy will usually be different from that for an 'equivalent' continuous low-dose-rate (CLDR) regime. For practical FHDR regimes involving relatively small numbers of fractions, the integrated biological effect to

  11. Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Deffet, Sylvain; Meijers, Arturs; Vander Stappen, Francois

    2016-12-01

    To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping. Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45 × 45 mm 2 field-of-view) of 9 × 9 spots capable of crossing the phantoms (210 MeV). The exit beam was collected by a MLIC to sample the integral depth dose (IDD MLIC ). PRs of an electron-density and of a head phantom were acquired by moving the couch to obtain multiple 45 × 45 mm 2 frames. To map the corresponding range errors, the two-dimensional set of IDD MLIC was compared with (i) the integral depth dose computed by the treatment planning system (TPS) by both analytic (IDD TPS ) and Monte Carlo (IDD MC ) algorithms in a volume of water simulating the MLIC at the CT, and (ii) the integral depth dose directly computed by a simple ray-tracing algorithm (IDD direct ) through the same CT data. The exact spatial position of the spot pattern was numerically adjusted testing different in-plane positions and selecting the one that minimized the range differences between IDD direct and IDD MLIC . Range error mapping was feasible by both the TPS and the ray-tracing methods, but very sensitive to even small misalignments. In homogeneous regions, the range errors computed by the direct ray-tracing algorithm matched the results obtained by both the analytic and the Monte Carlo algorithms. In both phantoms, lateral heterogeneities were better modeled by the ray-tracing and the Monte Carlo algorithms than by the analytic TPS computation. Accordingly, when the pencil beam crossed lateral heterogeneities, the range errors mapped by the direct algorithm matched better the Monte Carlo maps than those obtained by the analytic algorithm. Finally, the simplicity of the ray-tracing algorithm allowed to implement a prototype procedure for automated spatial alignment. The ray-tracing algorithm can reliably replace the TPS method in MLIC PR for in

  12. Integrated light-sheet imaging and flow-based enquiry (iLIFE) system for 3D in-vivo imaging of multicellular organism

    Science.gov (United States)

    Rasmi, Chelur K.; Padmanabhan, Sreedevi; Shirlekar, Kalyanee; Rajan, Kanhirodan; Manjithaya, Ravi; Singh, Varsha; Mondal, Partha Pratim

    2017-12-01

    We propose and demonstrate a light-sheet-based 3D interrogation system on a microfluidic platform for screening biological specimens during flow. To achieve this, a diffraction-limited light-sheet (with a large field-of-view) is employed to optically section the specimens flowing through the microfluidic channel. This necessitates optimization of the parameters for the illumination sub-system (illumination intensity, light-sheet width, and thickness), microfluidic specimen platform (channel-width and flow-rate), and detection sub-system (camera exposure time and frame rate). Once optimized, these parameters facilitate cross-sectional imaging and 3D reconstruction of biological specimens. The proposed integrated light-sheet imaging and flow-based enquiry (iLIFE) imaging technique enables single-shot sectional imaging of a range of specimens of varying dimensions, ranging from a single cell (HeLa cell) to a multicellular organism (C. elegans). 3D reconstruction of the entire C. elegans is achieved in real-time and with an exposure time of few hundred micro-seconds. A maximum likelihood technique is developed and optimized for the iLIFE imaging system. We observed an intracellular resolution for mitochondria-labeled HeLa cells, which demonstrates the dynamic resolution of the iLIFE system. The proposed technique is a step towards achieving flow-based 3D imaging. We expect potential applications in diverse fields such as structural biology and biophysics.

  13. On the feasibility of dose quantification with in-beam PET data in radiotherapy with 12C and proton beams

    International Nuclear Information System (INIS)

    Parodi, K.

    2004-11-01

    The physical advantages of light ions in combination with technological advances like intensity controlled raster scanning offer a unique tool for high precision radiotherapy. This is particularly applied to delicate clinical situations of inoperable tumours growing in close proximity to critical organs. The potential benefit of such a high selectivity of ion beam therapy demands the complex and strictly conformal dose delivery to be monitored in-situ and non-invasively in three dimensions. In contrast to conventional photon radiation, light ions exhibit a well defined range which determines the position of the maximum dose delivery in the inhomogeneous tumour target. This requires a monitoring technology along the ion trajectory offering millimetre precision. Additionally, accurate control of the lateral position of the irradiation field within the patient can be a crucial issue for the frequent case of portals passing adjacent to organs at risk. At present, positron emission tomography (PET) represents the only feasible method fulfilling these requirements. For this purpose a dedicated in-beam positron camera has been completely integrated into the experimental heavy ion treatment site at the Gesellschaft fuer Schwerionenforschung (GSI) Darmstadt. This allows to measure the minor amount of β + -activity produced in nuclear reactions between the projectiles and the target nuclei of the tissue simultaneously to the tumour irradiation. The emitted signal is correlated but not directly proportional to the spatial pattern of the delivered dose. Hence, therapy control is achieved by comparing the measured β + -activity distribution with a prediction based on the treatment plan and the specific time course of the particular irradiation. (orig.)

  14. The minimum measurable dose of CaF{sub 2}:Dy measured via an improved heating profile with an automatic 6600 thermoluminescent detector

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shachar, B; Weinstein, M; German, U [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    One of the advantages of the thermoluminescent method is its ability to measure low doses, which is useful in environmental dosimetry, as well as in archaeology. The CaF{sub 2}:Dy (Crown as TLD-200), has a sensitivity of 10-30 times greater than the sensitivity of TLD-100, when irradiated by Cs-137. In the present work we evaluated the TL-dose response of CaF{sub 2}:Dy, by using an improved heating profile which is giving the main glow peak alone. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses (MMD) were derived. The MMD were calculated by taking 3 times the standard deviation of the unirradiated chips. The results of the TL-dose response, as well as file fee calculated MMD by taxing 3 times the standard deviation of unirradiated chips, measured by file new 6600 automatic thermoluminescent detector, are presented in this work. We received a MMD of about 0.01 mGy (1 mrad), an improvement of a factor of 2.5 relatively to the integral light response evaluation using the standard heating profile (authors).

  15. Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

    International Nuclear Information System (INIS)

    Levegrün, Sabine; Pöttgen, Christoph; Wittig, Andrea; Lübcke, Wolfgang; Abu Jawad, Jehad; Stuschke, Martin

    2013-01-01

    Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N mets ) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV mets ) and of the individual metastasis planning target volume (PTV ind met ) were 8.7 ± 8.9 cm 3 (range, 1.3-35.5 cm 3 ) and 2.5 ± 4.5 cm 3 (range, 0.19-24.7 cm 3 ), respectively. Dose distributions in PTV mets and PTV ind met were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N mets was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV mets amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV ind met were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV mets (CN = 0.737 for PTV mets ≤4.32 cm 3 vs CN = 0.848 for PTV mets >4.32 cm 3 , P=.006), in contrast to N mets . The achieved dose conformity to PTV mets , assessed by both CN and PITV, was in all investigated volume strata

  16. Radiation doses in alternative commercial high-level waste management systems

    International Nuclear Information System (INIS)

    Schneider, K.J.; Pelto, P.J.; Lavender, J.C.; Daling, P.M.; Fecht, B.A.

    1986-01-01

    In the commercial high-level waste management system, potential changes are being considered that will augment the benefits of an integral monitored retrievable storage (MRS) facility. The US Department of Energy (DOE) has recognized that alternative options could be implemented in the authorized waste management system (i.e., without an integral MRS facility) to potentially achieve some of the same beneficial effects of the integral MRS system. This paper summarizes those DOE-sponsored analyses related to radiation doses resulting from changes in the waste management system. This report presents generic analyses of aggregated radiation dose impacts to the public and occupational workers, of nine postulated changes in the operation of a spent-fuel management system without an MRS facility

  17. Quantum hologram of macroscopically entangled light via the mechanism of diffuse light storage

    International Nuclear Information System (INIS)

    Gerasimov, L V; Sokolov, I M; Kupriyanov, D V; Havey, M D

    2012-01-01

    In this paper, we consider a quantum memory scheme for light diffusely propagating through a spatially disordered atomic gas. A unique characteristic is enhanced trapping of the signal light pulse by quantum multiple scattering, which can be naturally integrated with the mechanism of stimulated Raman conversion into a long-lived spin coherence. Then, the quantum state of the light can be mapped onto the disordered atomic spin subsystem and can be stored in it for a relatively long time. The proposed memory scheme can be applicable for storage of the macroscopic analogue of the Ψ (−) Bell state and the prepared entangled atomic state performs its quantum hologram, which suggests the possibility of further quantum information processing. (paper)

  18. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  19. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  20. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  1. The attenuation effect of UVc radiation doses in gram-negative bacteria (Brucella, Yersinia, Escherichia coli)

    International Nuclear Information System (INIS)

    Al-Mariri, A.

    2007-01-01

    The gram-negative bacteria Yersinia enterocolitica sero group O:3 and O:9, and Brucella (Melitensis and abortus) together with Escherichia coli (O:157, DH5alpha-pEt15b), were investigated to evaluate their susceptibility to UV radiation at 254 nm. If the dose of UVc was 18.7 mW/cm2, the time required for inactivation of Y. enterocolitica and E. coli DH5alpha-pEt15b and O:157 was 240s and 360s in the dark and light respectively. Where if the dose was 19.5 mW/cm2, the time required was 60s in the dark and 120s in light respectively. The time required for inactivation of Brucella strains (melitensis and abortus) if the dose was 18.7 mW/cm2 was 240s in both dark and light, whereas it was 120s (dark) and 240s (light) respectively, when the dose was 19.5 mW/cm2. Using E. coli O:157 as control, it appears that Y. enterocolitica sero group O:3 and O:9 and vaccinal strains of Brucella (Rev. 1 and S19) are more sensitive to UV than wild Brucella strains. No relation was found between the sensitivity of Y. enterocolitica to UV and the presence or absence of a pYV+ virulence plasmid. (author)

  2. The attenuation effect of UVc radiation doses in gram-negative bacteria (Brucella, Yersinia, Escherichia coli)

    International Nuclear Information System (INIS)

    Al-Mariri, A.

    2006-06-01

    The gram-negative bacteria Yersinia enterocolitica sero group O:3 and O:9, and Brucella (Melitensis and abortus) together with Escherichia coli (O:157, DH5α-pEt15b), were investigated to evaluate their susceptibility to UV radiation at 254 nm. If the dose of UVc was 18.7 mW/cm 2 , the time required for inactivation of Y. enterocolitica and E. coli DH5α-pEt15b and O:157 was 240s and 360s in the dark and light respectively; where if the dose was 19.5 mW/cm 2 , the time required was 60s in the dark and 120s in light respectively. The time required for inactivation of Brucella strains (melitensis and abortus) if the dose was 18.7 mW/cm 2 was 240s in both dark and light, whereas it was 120s(dark) and 240s (light) respectively, when the dose was 19.5 mW/cm 2 . Using E. coli O:157 as control, it appears that Y. enterocolitica sero group O:3 and O:9 and vaccinal strains of Brucella (Rev. 1 and S19) are more sensitive to UV than wild Brucella strains. No relation was found between the sensitivity of Y. enterocolitica to UV and the presence or absence of a pYV + virulence plasmid. (author)

  3. Light Rhythms in Architecture

    DEFF Research Database (Denmark)

    Bülow, Katja

    2013-01-01

    formation and rhythm. When integrated into an architectural concept, electrical lighting non-intended for poetic composition has the ability to contribute to place, time, and function-telling aspects of places in urban contexts. Urban environments are information wise challenging to pre-historic human...

  4. Cost-efficient light control for production of two campanula species

    DEFF Research Database (Denmark)

    Kjær, Katrine Heinsvig; Ottosen, Carl-Otto; Nørregaard Jørgensen, Bo

    2011-01-01

    . This was caused by a combination of the irregular light, low natural light intensities and a decrease in daily light integral (DLI), and could be restored by maintaining a continuous 19 h photoperiod with incandescent lamps (photoperiod was an important factor for flowering...

  5. The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material

    International Nuclear Information System (INIS)

    Moscovitch, M.; Benevides, L.; Romanyukha, A.; Hull, F.; Duffy, M.; Voss, S.; Velbeck, K. J.; Nita, I.; Rotunda, J. E.

    2011-01-01

    The photo-transferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼6 % in the dose range of 0.2 mGy -1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated. (authors)

  6. Light-emitting device test systems

    Science.gov (United States)

    McCord, Mark; Brodie, Alan; George, James; Guan, Yu; Nyffenegger, Ralph

    2018-01-23

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  7. A Multifunctional Public Lighting Infrastructure, Design and Experimental Test

    OpenAIRE

    Marco Beccali; Valerio Lo Brano; Marina Bonomolo; Paolo Cicero; Giacomo Corvisieri; Marco Caruso; Francesco Gamberale

    2017-01-01

    Nowadays, the installation of efficient lighting sources and Information and Communications Technologies can provide economic benefits, energy efficiency, and visual comfort requirements. More advantages can be derived if the public lighting infrastructure integrates a smart grid. This study presents an experimental multifunctional infrastructure for public lighting, installed in Palermo. The system is able to provide smart lighting functions (hotspot Wi-Fi, video-surveillances, car and pedes...

  8. Prospects for detection of intermediate-mass black holes in globular clusters using integrated-light spectroscopy

    Science.gov (United States)

    de Vita, R.; Trenti, M.; Bianchini, P.; Askar, A.; Giersz, M.; van de Ven, G.

    2017-06-01

    The detection of intermediate-mass black holes (IMBHs) in Galactic globular clusters (GCs) has so far been controversial. In order to characterize the effectiveness of integrated-light spectroscopy through integral field units, we analyse realistic mock data generated from state-of-the-art Monte Carlo simulations of GCs with a central IMBH, considering different setups and conditions varying IMBH mass, cluster distance and accuracy in determination of the centre. The mock observations are modelled with isotropic Jeans models to assess the success rate in identifying the IMBH presence, which we find to be primarily dependent on IMBH mass. However, even for an IMBH of considerable mass (3 per cent of the total GC mass), the analysis does not yield conclusive results in one out of five cases, because of shot noise due to bright stars close to the IMBH line of sight. This stochastic variability in the modelling outcome grows with decreasing BH mass, with approximately three failures out of four for IMBHs with 0.1 per cent of total GC mass. Finally, we find that our analysis is generally unable to exclude at 68 per cent confidence an IMBH with mass of 103 M⊙ in snapshots without a central BH. Interestingly, our results are not sensitive to GC distance within 5-20 kpc, nor to misidentification of the GC centre by less than 2 arcsec (<20 per cent of the core radius). These findings highlight the value of ground-based integral field spectroscopy for large GC surveys, where systematic failures can be accounted for, but stress the importance of discrete kinematic measurements that are less affected by stochasticity induced by bright stars.

  9. Absorbed dose to the patient by computerized whole body X-ray tomography

    International Nuclear Information System (INIS)

    Krauss, O.; Schuhmacher, H.

    1977-01-01

    The absorbed dose to the patient was measured for several medical investigations by computerized whole body scanning. An Alderson-phantom mounted with LiF-TLD was irradiated with a Delta-Scan (Ohio-Nuclear, 120 kV, 30 mA). The integral dose to the brain during a full examination (6 scans, filtration 3 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 3.2 rd and at the exit 0.6 rd. The dose to the eyes is 0.7 rd and to the thyroid gland 0.03 rd. The integral dose to the trunk (5 scans in the region of liver and kidneys, filtration 6 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 2.4 rd and at the exit 0.25 rd. The dose to the gonads is less than 2 and 4 mrd if the distance between the last scan and the gonads is more than 15 cm

  10. Development of environmental dose assessment system (EDAS) code of PC version

    Energy Technology Data Exchange (ETDEWEB)

    Taki, Mitsumasa; Kikuchi, Masamitsu; Kobayashi, Hideo; Yamaguchi, Takenori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-05-01

    A computer code (EDAS) was developed to assess the public dose for the safety assessment to get the license of nuclear reactor operation. This code system is used for the safety analysis of public around the nuclear reactor in normal operation and severe accident. This code was revised and composed for personal computer user according to the Nuclear Safety Guidelines reflected the ICRP1990 recommendation. These guidelines are revised by Nuclear Safety Commission on March, 2001, which are 'Weather analysis guideline for the safety assessment of nuclear power reactor', 'Public dose around the facility assessment guideline corresponding to the objective value for nuclear power light water reactor' and 'Public dose assessment guideline for safety review of nuclear power light water reactor'. This code has been already opened for public user by JAERI, and English version code and user manual are also prepared. This English version code is helpful for international cooperation concerning the nuclear safety assessment with JAERI. (author)

  11. Development of environmental dose assessment system (EDAS) code of PC version

    CERN Document Server

    Taki, M; Kobayashi, H; Yamaguchi, T

    2003-01-01

    A computer code (EDAS) was developed to assess the public dose for the safety assessment to get the license of nuclear reactor operation. This code system is used for the safety analysis of public around the nuclear reactor in normal operation and severe accident. This code was revised and composed for personal computer user according to the Nuclear Safety Guidelines reflected the ICRP1990 recommendation. These guidelines are revised by Nuclear Safety Commission on March, 2001, which are 'Weather analysis guideline for the safety assessment of nuclear power reactor', 'Public dose around the facility assessment guideline corresponding to the objective value for nuclear power light water reactor' and 'Public dose assessment guideline for safety review of nuclear power light water reactor'. This code has been already opened for public user by JAERI, and English version code and user manual are also prepared. This English version code is helpful for international cooperation concerning the nuclear safety assessme...

  12. A polymeric dosimeter film based on optically-stimulated luminescence for dose measurements below 1 kGy

    International Nuclear Information System (INIS)

    Kovacs, A.; Baranyai, M.; Wojnarovits, L.; Slezsak, I.; McLaughlin, W.L.; Miller, S.D.; Miller, A.; Fuochi, P.G.; Lavalle, M.

    1999-01-01

    A new potential dosimetry system 'Sunna' containing a microcrystalline dispersion of an optically-stimulated fluor in a plastic matrix has been recently developed to measure and image high doses. Our previous investigations have revealed that the new dosimeter system is capable of measuring absorbed doses in the dose range of 1-100 kGy. The optically-stimulated luminescence (OSL) analysis is based on the blue light stimulation of the colour center states produced upon irradiation, and the intensity of the resulting red-light emission is used to measure absorbed dose. This analysis is carried out with a simple table-top fluorimeter developed for this purpose having also the ability to calculate the mathematical formula of the calibration function. The Sunna dosimeter was recently investigated for potential use in lower dose range below 1 kGy. These investigations have shown that the film is suitable for measuring doses in the range of 1-1000 Gy for both electron and gamma radiation. To test the applicability of the film, its reproducibility, stability, sensitivity to ambient and UV light and irradiation temperature were measured. The stability of the dosimeter was investigated by monitoring the change of the OSL signal with storage time after irradiation. Further experiments proved the homogeneity of the film with respect to thickness variation, and limited differences in its response were found between batches. (author)

  13. An optimized power conversion system concept of the integral, inherently-safe light water reactor

    International Nuclear Information System (INIS)

    Memmott, Matthew J.; Wilding, Paul R.; Petrovic, Bojan

    2017-01-01

    Highlights: • Three power conversion systems (PCS) for the I"2S-LWR are presented. • An optimization analyses was performed to evaluate these PCS alternatives. • The ideal PCS consists of 5 turbines, and obtains an overall efficiency of 35.7%. - Abstract: The integral, inherently safe light water reactor (I"2S-LWR) has been developed to significantly enhance passive safety capabilities while maintaining cost competitiveness relative to the current light water reactor (LWR) fleet. The compact heat exchangers of the I"2S-LWR preclude boiling of the secondary fluid, which decreases the probability of heat exchanger failure, but this requires the addition of a flash drum, which negatively affects the overall plant thermodynamic efficiency. A state of the art Rankine cycle is proposed for the I"2S-LWR to increase the thermodynamic efficiency by utilizing a flash drum with optimized operational parameters. In presenting this option for power conversion in the I"2S-LWR power plant, the key metric used in rating the performance is the overall net thermodynamic efficiency of the cycle. In evaluating the flash-Rankine cycle, three basic industrial concepts are evaluated, one without an intermediate pressure turbine, one with an intermediate turbine and one reheat stream, and one with an intermediate turbine and two reheat streams. For each configuration, a single-path multi-variable optimization is undertaken to maximize the thermal efficiency. The third configuration with an intermediate turbine and 2 reheat streams is the most effective concept, with an optimized efficiency of 35.7%.

  14. Projecting light beams with 3D waveguide arrays

    Science.gov (United States)

    Crespi, Andrea; Bragheri, Francesca

    2017-01-01

    Free-space light beams with complex intensity patterns, or non-trivial phase structure, are demanded in diverse fields, ranging from classical and quantum optical communications, to manipulation and imaging of microparticles and cells. Static or dynamic spatial light modulators, acting on the phase or intensity of an incoming light wave, are the conventional choices to produce beams with such non-trivial characteristics. However, interfacing these devices with optical fibers or integrated optical circuits often requires difficult alignment or cumbersome optical setups. Here we explore theoretically and with numerical simulations the potentialities of directly using the output of engineered three-dimensional waveguide arrays, illuminated with linearly polarized light, to project light beams with peculiar structures. We investigate through a collection of illustrative configurations the far field distribution, showing the possibility to achieve orbital angular momentum, or to produce elaborate intensity or phase patterns with several singularity points. We also simulate the propagation of the projected beam, showing the possibility to concentrate light. We note that these devices should be at reach of current technology, thus perspectives are open for the generation of complex free-space optical beams from integrated waveguide circuits.

  15. Strong relationship between DMS and the solar radiation dose over the global surface ocean.

    Science.gov (United States)

    Vallina, Sergio M; Simó, Rafel

    2007-01-26

    Marine biogenic dimethylsulfide (DMS) is the main natural source of tropospheric sulfur, which may play a key role in cloud formation and albedo over the remote ocean. Through a global data analysis, we found that DMS concentrations are highly positively correlated with the solar radiation dose in the upper mixed layer of the open ocean, irrespective of latitude, plankton biomass, or temperature. This is a necessary condition for the feasibility of a negative feedback in which light-attenuating DMS emissions are in turn driven by the light dose received by the pelagic ecosystem.

  16. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  17. Identification of molecular candidates and interaction networks via integrative toxicogenomic analysis in a human cell line following low-dose exposure to the carcinogenic metals cadmium and nickel.

    Science.gov (United States)

    Kwon, Jee Young; Weon, Jong-Il; Koedrith, Preeyaporn; Park, Kang-Sik; Kim, Im Soon; Seo, Young Rok

    2013-09-01

    Cadmium and nickel have been classified as carcinogenic to humans by the World Health Organization's International Agency for Research on Cancer. Given their prevalence in the environment, the fact that cadmium and nickel may cause diseases including cancer even at low doses is a cause for concern. However, the exact mechanisms underlying the toxicological effects induced by low-dose exposure to cadmium and nickel remain to be elucidated. Furthermore, it has recently been recognized that integrative analysis of DNA, mRNA and proteins is required to discover biomarkers and signaling networks relevant to human toxicant exposure. In the present study, we examined the deleterious effects of chronic low-dose exposure of either cadmium or nickel on global profiling of DNA copy number variation, mRNA and proteins. Array comparative genomic hybridization, gene expression microarray and functional proteomics were conducted, and a bioinformatics tool, which predicted signaling pathways, was applied to integrate data for each heavy metal separately and together. We found distinctive signaling networks associated with subchronic low-dose exposure to cadmium and nickel, and identified pathways common to both. ACTB, HSP90AA1, HSPA5 and HSPA8, which are key mediators of pathways related to apoptosis, proliferation and neoplastic processes, were key mediators of the same pathways in low-dose nickel and cadmium exposure in particular. CASP-associated signaling pathways involving CASP3, CASP7 and CASP9 were observed in cadmium-exposed cells. We found that HSP90AA1, one of the main modulators, interacted with HIF1A, AR and BCL2 in nickel-exposed cells. Interestingly, we found that HSP90AA1 was involved in the BCL2-associated apoptotic pathway in the nickel-only data, whereas this gene interacted with several genes functioning in CASP-associated apoptotic signaling in the cadmium-only data. Additionally, JUN and FASN were main modulators in nickel-responsive signaling pathways. Our

  18. Comparison of UV-C and Pulsed UV Light Treatments for Reduction of Salmonella, Listeria monocytogenes, and Enterohemorrhagic Escherichia coli on Eggs.

    Science.gov (United States)

    Holck, Askild L; Liland, Kristian H; Drømtorp, Signe M; Carlehög, Mats; McLEOD, Anette

    2018-01-01

    Ten percent of all strong-evidence foodborne outbreaks in the European Union are caused by Salmonella related to eggs and egg products. UV light may be used to decontaminate egg surfaces and reduce the risk of human salmonellosis infections. The efficiency of continuous UV-C (254 nm) and pulsed UV light for reducing the viability of Salmonella Enteritidis, Listeria monocytogenes, and enterohemorrhagic Escherichia coli on eggs was thoroughly compared. Bacterial cells were exposed to UV-C light at fluences from 0.05 to 3.0 J/cm 2 (10 mW/cm 2 , for 5 to 300 s) and pulsed UV light at fluences from 1.25 to 18.0 J/cm 2 , resulting in reductions ranging from 1.6 to 3.8 log, depending on conditions used. Using UV-C light, it was possible to achieve higher reductions at lower fluences compared with pulsed UV light. When Salmonella was stacked on a small area or shielded in feces, the pulsed UV light seemed to have a higher penetration capacity and gave higher bacterial reductions. Microscopy imaging and attempts to contaminate the interior of the eggs with Salmonella through the eggshell demonstrated that the integrity of the eggshell was maintained after UV light treatments. Only minor sensory changes were reported by panelists when the highest UV doses were used. UV-C and pulsed UV light treatments appear to be useful decontamination technologies that can be implemented in continuous processing.

  19. The National Dose Registration and Information System: Dose distributions in the Netherlands over the period 1989-1993

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Julius, H.W.; Bogaerde, M.A. van de

    1994-01-01

    In 1988 the Ministry of Social Affairs and Employment commissioned TNO Radiological Service to set up a National Dose REgistration and Information System (NDRIS). The government had three reasons in view to build NDRIS: To improve radiation protection by supervising the occupational doses of radiation workers by using one central database system; To improve the reliability of long term storage of dose data; To improve the possibilities for statistical analysis of occupational doses to guide policy making. Each approved dosimetry service (ADS) in the country sends its dose information to NDRIS on a monthly basis. IN its turn NDRIS sends back for each worker monitored by that ADS, the integrated dose as measured by any ADS. This creates the possibility for each ADS to report to the workers their total annual dose irrespectively whether they work for more than one employer or are monitored by more than one ADS, either simultaneously or successively in the course of the year. European legislation requires that the occupational dose should be controlled in this way. The availability of the centralized database replaces the need of a radiation passbook for national use. The passbook that is needed by radiation workers during interstate travelling can be produced using data from NDRIS

  20. Assessment of internal doses

    CERN Document Server

    Rahola, T; Falk, R; Isaksson, M; Skuterud, L

    2002-01-01

    There is a definite need for training in dose calculation. Our first course was successful and was followed by a second, both courses were fully booked. An example of new tools for software products for bioassay analysis and internal dose assessment is the Integrated Modules for Bioassay Analysis (IMBA) were demonstrated at the second course. This suite of quality assured code modules have been adopted in the UK as the standard for regulatory assessment purposes. The intercomparison measurements are an important part of the Quality Assurance work. In what is known as the sup O utside workers ' directive it is stated that the internal dose measurements shall be included in the European Unions supervision system for radiation protection. The emergency preparedness regarding internal contamination was much improved by the training with and calibration of handheld instruments from participants' laboratories. More improvement will be gained with the handbook giving practical instructions on what to do in case of e...

  1. High-speed radiation dose calculations for severe accidents using INDOS

    International Nuclear Information System (INIS)

    Davidson, G.R.; Godin-Jacqmin, L.J.; Raines, J.C.

    1992-01-01

    The computer code INDOS (in-plant dose) has been developed for the high-speed calculation of in-plant radiation dose rates and doses during and/or due to a severe accident at a nuclear power plant. This paper describes the current capabilities of the code and presents the results of calculations for several severe-accident scenarios. The INDOS code can be run either as a module of MAAP, a code widely used in the nuclear industry for simulating the response of a light water reactor system during severe accidents, or as a stand-alone code using output from an alternative companion code. INDOS calculates gamma dose rates and doses in major plant compartments caused by airborne and deposited fission products released during an accident. The fission product concentrations are determined by the companion code

  2. An integral heuristic

    International Nuclear Information System (INIS)

    Kauffman, L.H.

    1990-01-01

    This paper gives a heuristic derivation of the skein relation for the Homfly polynomial in an integral formalism. The derivation is formally correct but highly simplified. In the light of Witten's proposal for invariants of links via functional integrals, it is useful to have a formal pattern to compare with the complexities of the full approach. The formalism is a heuristic. However, it is closely related to the actual structure of the Witten functional integral

  3. Application of the dose limitation system to the control of carbon-14 releases from heavy-water-moderated reactors

    International Nuclear Information System (INIS)

    Beninson, D.; Gonzalez, A.J.

    1982-01-01

    Heavy-water-moderated reactors produce substantially more carbon-14 than light-water reactors. Applying the principles of the systems of dose limitation, the paper presents the rationale used for establishing the release limit for effluents containing this nuclide and for the decisions made regarding the effluent treatment in the third nuclear power station in Argentina. Production of carbon-14 in PHWR and the release routes are analysed in the light of the different effluent treatment possibilities. An optimization assessment is presented, taking into account effluent treatment and waste management costs, and the collective effective dose commitment due to the releases. The contribution of present carbon-14 releases to future individual doses is also analysed in the light of an upper bound for the contribution, representing a fraction of the individual dose limits. The paper presents the resulting requirements for the effluent treatment regarding carbon-14 and the corresponding regulatory aspects used in Argentina. (author)

  4. Manipulating structured light

    CSIR Research Space (South Africa)

    Dudley, Angela

    2016-07-01

    Full Text Available SINGULARITY ZERO INTENSITY GAUSSIAN BEAM LAGUERRE-GAUSSIAN BEAM u(r,θ,z) = u0(r,z)exp(ilθ) Our favorite structured light field – has a helical wavefront 10/10/2016 6 Many unique measurement techniques are available for structured light NJP 13, 093014 (2011...). PRL 105(15), 153601 (2010).Nature 412, 314-316 (2001). PRL 105(5), 053904 (2010). PRL 88(25), 257901 (2002). 6? � � � ��Ψ� � �� c1 c2 c3 ∫ ∫ Ψ=Ψ== dxdyUUic nnnnn * ,)exp( φρ Create these modesPerform this integral Modal decomposition expands...

  5. Globular Cluster Abundances from High-resolution, Integrated-light Spectroscopy. IV. The Large Magellanic Cloud: α, Fe-peak, Light, and Heavy Elements

    Science.gov (United States)

    Colucci, Janet E.; Bernstein, Rebecca A.; Cameron, Scott A.; McWilliam, Andrew

    2012-02-01

    We present detailed chemical abundances in eight clusters in the Large Magellanic Cloud (LMC). We measure abundances of 22 elements for clusters spanning a range in age of 0.05-12 Gyr, providing a comprehensive picture of the chemical enrichment and star formation history of the LMC. The abundances were obtained from individual absorption lines using a new method for analysis of high-resolution (R ~ 25,000), integrated-light (IL) spectra of star clusters. This method was developed and presented in Papers I, II, and III of this series. In this paper, we develop an additional IL χ2-minimization spectral synthesis technique to facilitate measurement of weak (~15 mÅ) spectral lines and abundances in low signal-to-noise ratio data (S/N ~ 30). Additionally, we supplement the IL abundance measurements with detailed abundances that we measure for individual stars in the youngest clusters (age +0.5) and increases with decreasing age, indicating a strong contribution of low-metallicity asymptotic giant branch star ejecta to the interstellar medium throughout the later history of the LMC. We also find a correlation of IL Na and Al abundances with cluster mass in the sense that more massive, older clusters are enriched in the light elements Na and Al with respect to Fe, which implies that these clusters harbor star-to-star abundance variations as is common in the MW. Lower mass, intermediate-age, and young clusters have Na and Al abundances that are lower and more consistent with LMC field stars. Our results can be used to constrain both future chemical evolution models for the LMC and theories of globular cluster formation. This paper includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile.

  6. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    Science.gov (United States)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  7. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-01-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  8. Monte Carlo calculation of ''skyshine'' neutron dose from ALS [Advanced Light Source

    International Nuclear Information System (INIS)

    Moin-Vasiri, M.

    1990-06-01

    This report discusses the following topics on ''skyshine'' neutron dose from ALS: Sources of radiation; ALS modeling for skyshine calculations; MORSE Monte-Carlo; Implementation of MORSE; Results of skyshine calculations from storage ring; and Comparison of MORSE shielding calculations

  9. Development of Graphical User Interface for ARRBOD (Acute Radiation Risk and BRYNTRN Organ Dose Projection)

    Science.gov (United States)

    Kim, Myung-Hee; Hu, Shaowen; Nounu, Hatem N.; Cucinotta, Francis A.

    2010-01-01

    The space radiation environment, particularly solar particle events (SPEs), poses the risk of acute radiation sickness (ARS) to humans; and organ doses from SPE exposure may reach critical levels during extra vehicular activities (EVAs) or within lightly shielded spacecraft. NASA has developed an organ dose projection model using the BRYNTRN with SUMDOSE computer codes, and a probabilistic model of Acute Radiation Risk (ARR). The codes BRYNTRN and SUMDOSE, written in FORTRAN, are a Baryon transport code and an output data processing code, respectively. The ARR code is written in C. The risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. BRYNTRN code operation requires extensive input preparation. With a graphical user interface (GUI) to handle input and output for BRYNTRN, the response models can be connected easily and correctly to BRYNTRN in friendly way. A GUI for the Acute Radiation Risk and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations, which are required for operations of the ARRBOD modules: BRYNTRN, SUMDOSE, and the ARR probabilistic response model. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. The ARRBOD GUI will serve as a proof-of-concept example for future integration of other human space applications risk projection models. The current version of the ARRBOD GUI is a new self-contained product and will have follow-on versions, as options are added: 1) human geometries of MAX/FAX in addition to CAM/CAF; 2) shielding distributions for spacecraft, Mars surface and atmosphere; 3) various space environmental and biophysical models; and 4) other response models to be connected to the BRYNTRN. The major components of the overall system, the subsystem interconnections, and external interfaces are described in this

  10. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  11. A conceptual framework for managing radiation dose to patients in diagnostic radiology using reference dose levels

    International Nuclear Information System (INIS)

    Almen, Anja; Baath, Magnus

    2016-01-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. (authors)

  12. Radiation dose to neonates on a Special Care Baby Unit

    International Nuclear Information System (INIS)

    Faulkner, K.; Barry, J.L.; Smalley, P.

    1989-01-01

    The skin entrance dose to neonates on a special care baby unit was estimated from a knowledge of the technique factors, X-ray tube output and backscatter factors. Normalized organ dose data were employed to estimate radiation dose to a number of critical organs. Methods of reducing radiation dose to neonates were investigated. Initially, this involved changing the radiographic technique factors and introducing a lead rubber adjustable collimator, placed on top of the incubator, in addition to light beam diaphragms on the X-ray tube. These modifications to the examination technique appeared to reduce average entrance dose per radiograph from 92 μGy, to 58 μGy, a reduction of 37%. Later, a rare-earth film-screen combination was introduced to replace existing fast calcium tungstate screens. This enabled average entrance dose per radiograph to be reduced to 39 μGy, a further reduction of 33%. The mean radiation dose to a neonate is mainly determined by the number of radiographs. (author)

  13. Radiation dose to neonates on a Special Care Baby Unit

    Energy Technology Data Exchange (ETDEWEB)

    Faulkner, K.; Barry, J.L.; Smalley, P.

    1989-03-01

    The skin entrance dose to neonates on a special care baby unit was estimated from a knowledge of the technique factors, X-ray tube output and backscatter factors. Normalized organ dose data were employed to estimate radiation dose to a number of critical organs. Methods of reducing radiation dose to neonates were investigated. Initially, this involved changing the radiographic technique factors and introducing a lead rubber adjustable collimator, placed on top of the incubator, in addition to light beam diaphragms on the X-ray tube. These modifications to the examination technique appeared to reduce average entrance dose per radiograph from 92 ..mu..Gy, to 58 ..mu..Gy, a reduction of 37%. Later, a rare-earth film-screen combination was introduced to replace existing fast calcium tungstate screens. This enabled average entrance dose per radiograph to be reduced to 39 ..mu..Gy, a further reduction of 33%. The mean radiation dose to a neonate is mainly determined by the number of radiographs.

  14. Understanding the central kinematics of globular clusters with simulated integrated-light IFU observations

    Science.gov (United States)

    Bianchini, Paolo; Norris, Mark A.; van de Ven, Glenn; Schinnerer, Eva

    2015-10-01

    The detection of intermediate-mass black holes in the centres of globular clusters is highly controversial, as complementary observational methods often deliver significantly different results. In order to understand these discrepancies, we develop a procedure to simulate integral field unit (IFU) observations of globular clusters: Simulating IFU Star Cluster Observations (SISCO). The inputs of our software are realistic dynamical models of globular clusters that are then converted in a spectral data cube. We apply SISCO to Monte Carlo cluster simulations with a realistic number of stars and concentrations. Using independent realizations of a given simulation we are able to quantify the stochasticity intrinsic to the problem of observing a partially resolved stellar population with integrated-light spectroscopy. We show that the luminosity-weighted IFU observations can be strongly biased by the presence of a few bright stars that introduce a scatter in the velocity dispersion measurements up to ≃40 per cent around the expected value, preventing any sound assessment of the central kinematic and a sensible interpretation of the presence/absence of an intermediate-mass black hole. Moreover, we illustrate that, in our mock IFU observations, the average kinematic tracer has a mass of ≃0.75 M⊙, only slightly lower than the mass of the typical stars examined in studies of resolved line-of-sight velocities of giant stars. Finally, in order to recover unbiased kinematic measurements we test different masking techniques that allow us to remove the spaxels dominated by bright stars, bringing the scatter down to a level of only a few per cent. The application of SISCO will allow us to investigate state-of-the-art simulations as realistic observations.

  15. Detecting and locating light atoms from high-resolution STEM images: The quest for a single optimal design

    Energy Technology Data Exchange (ETDEWEB)

    Gonnissen, J.; De Backer, A. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Dekker, A.J. den [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Delft Center for Systems and Control (DCSC), Delft University of Technology, Mekelweg 2, 2628 CD Delft (Netherlands); Sijbers, J. [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Van Aert, S., E-mail: sandra.vanaert@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2016-11-15

    In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramér–Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms. - Highlights: • The optimal detector design to detect and locate light atoms in HR STEM is derived. • The probability of error is quantified and used to detect light atoms. • The Cramér–Rao lower bound is calculated to determine the atomic column precision. • Both measures are evaluated and result in the single optimal LAADF detector regime. • The incoming electron dose is optimised for both research goals.

  16. Dose reduction using Bismuth protectors in chest computed tomography

    International Nuclear Information System (INIS)

    Anaya, R.

    2012-01-01

    This monography is about the Dose reduction using Bismuth protectors in chest CT. The radiation protection of specific areas is necessary when the tissues or radiosensitive organs are near the path of light beam. The correct use of protection represents a challenge for the radiologist because of the time and materials required. The method used was a prospective investigatio in CHPR (TC service) and the doses was measured with TLD dosimeters. It is important to use these protectors in children hospitals.

  17. On the feasibility of dose quantification with in-beam PET data in radiotherapy with {sup 12}C and proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Parodi, K.

    2004-11-01

    The physical advantages of light ions in combination with technological advances like intensity controlled raster scanning offer a unique tool for high precision radiotherapy. This is particularly applied to delicate clinical situations of inoperable tumours growing in close proximity to critical organs. The potential benefit of such a high selectivity of ion beam therapy demands the complex and strictly conformal dose delivery to be monitored in-situ and non-invasively in three dimensions. In contrast to conventional photon radiation, light ions exhibit a well defined range which determines the position of the maximum dose delivery in the inhomogeneous tumour target. This requires a monitoring technology along the ion trajectory offering millimetre precision. Additionally, accurate control of the lateral position of the irradiation field within the patient can be a crucial issue for the frequent case of portals passing adjacent to organs at risk. At present, positron emission tomography (PET) represents the only feasible method fulfilling these requirements. For this purpose a dedicated in-beam positron camera has been completely integrated into the experimental heavy ion treatment site at the Gesellschaft fuer Schwerionenforschung (GSI) Darmstadt. This allows to measure the minor amount of {beta}{sup +}-activity produced in nuclear reactions between the projectiles and the target nuclei of the tissue simultaneously to the tumour irradiation. The emitted signal is correlated but not directly proportional to the spatial pattern of the delivered dose. Hence, therapy control is achieved by comparing the measured {beta}{sup +}-activity distribution with a prediction based on the treatment plan and the specific time course of the particular irradiation. (orig.)

  18. SU-F-T-329: Characteristic Study of a Rado-Photoluminescenct Glass Dosimeter with Accumulated Dose

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D; Chung, W; Chung, M [Kyung Hee University Hospital at Gangdong, Gangdong-gu (Korea, Republic of); Yoon, M [Korea University, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: This study investigated the effect of accumulated dose on radiophotoluminescent glass dosimeter in megavoltage photon. Methods: 45 commercially-available radio-photoluminescence glass dosimeters (RPLGD; GD-302M, Asahi Techno Glass Co., Shizuoka, JAPAN) were irradiated to 10 × 10 cm{sup 2} open-field with 6, 10 and 15 MV photon beams at 100 cm of source to surface distance and dose maximum depths. Each energy has consists of five groups which is consists of three detectors. A group #1 and #2 was irradiated about 1 Gy to 100 Gy, and estimated the integral dose response with and without annealing procedure. A group #3 was read the dose after irradiated 10 Gy of dose by 10 times repeatedly to estimate the fading effect of RPLGD. A group #4 and #5 was produced same ways with different irradiation dose such as 50 Gy for group #4 and 100 Gy for group #5. Results: From the results of group #1 and #2, an annealed detector shows linear response to integral dose but other detectors without the annealing process, has supra linearity for integral dose especially close to 100 Gy dose. For group #3, #4 and #5, the dose response of repeated irradiation, the dose response was decreased about 15%, 12% and 7% for 6 MV, 10 MV and 15MV. Conclusion: It was found that RPLGD response to accumulated dose was supra linear and this respond was altered with amount of accumulated dose to the RPLGD. In addition, the fading effect need to be concern with RPLGD.

  19. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  20. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  1. Analysis of a Statistical Relationship Between Dose and Error Tallies in Semiconductor Digital Integrated Circuits for Application to Radiation Monitoring Over a Wireless Sensor Network

    Science.gov (United States)

    Colins, Karen; Li, Liqian; Liu, Yu

    2017-05-01

    Mass production of widely used semiconductor digital integrated circuits (ICs) has lowered unit costs to the level of ordinary daily consumables of a few dollars. It is therefore reasonable to contemplate the idea of an engineered system that consumes unshielded low-cost ICs for the purpose of measuring gamma radiation dose. Underlying the idea is the premise of a measurable correlation between an observable property of ICs and radiation dose. Accumulation of radiation-damage-induced state changes or error events is such a property. If correct, the premise could make possible low-cost wide-area radiation dose measurement systems, instantiated as wireless sensor networks (WSNs) with unshielded consumable ICs as nodes, communicating error events to a remote base station. The premise has been investigated quantitatively for the first time in laboratory experiments and related analyses performed at the Canadian Nuclear Laboratories. State changes or error events were recorded in real time during irradiation of samples of ICs of different types in a 60Co gamma cell. From the error-event sequences, empirical distribution functions of dose were generated. The distribution functions were inverted and probabilities scaled by total error events, to yield plots of the relationship between dose and error tallies. Positive correlation was observed, and discrete functional dependence of dose quantiles on error tallies was measured, demonstrating the correctness of the premise. The idea of an engineered system that consumes unshielded low-cost ICs in a WSN, for the purpose of measuring gamma radiation dose over wide areas, is therefore tenable.

  2. Cell damage by bilirubin and light

    International Nuclear Information System (INIS)

    Granli, T.

    1993-01-01

    Large doses of light are given to newborns during phototherapy for hyperbilirubinemia. Tissues containing concentrations of bilirubin almost in the mM range may be subjected to irradiation. Therefore it is of interest to study cellular effects of light and bilirubin on cells. In order to select the optimal wavelength, possible detrimental effects of light on cells must be taken into consideration among a number of other factors. In this study cellular effects of selected wavelengths of blue-green light are compared. It is not clear whether cullular damage occurs in vivo during phototherapy of newborns. Since a possibility exists that some adverse effects are caused by light, one should choose wavelengths where these effects are minimal without loosing therapeutic efficiency. Todays knowledge of the photochemical mechanisms of phototherapy, indicates that short waved light with wavelengths below 450 nm has a low therapeutic effect. The data in this paper indicate that the cellular damage is most severe at short wavelengths, and these should be reduced to a minimum in the spectra of phototherapy lamps. Further studies of possible side effects of phototherapy should be made. 64 refs., 34 figs., 1 tab

  3. Light pulse shapes from plastic scintillators

    International Nuclear Information System (INIS)

    Moszynski, M.; Bengtson, B.

    1977-01-01

    A detailed study of the light pulse shape from the binary NE 111 and the ternary Pilot U, Naton 136, KL 236, NE 102A, NE 104 and NE 110 plastic scintillators was performed by the single photon method using XP 1021 and C 31024 photomultipliers. The analysis of the shape of the light pulses determined experimentally for several samples of different dimensions gave the following conclusions. The original light pulse shape from the binary NE 111 scintillator, as measured with a 5 mm thick polished sample is described analytically by the convolution integral of a Gaussian and an exponential function. The Gaussian function may reflect a deexcitation of several higher levels of the solvent molecules excited by nuclear particles preceding an intermolecular energy transfer in the scintillator. It may introduce a rather important limitation of the speed of plastic scintillators as the standard deviation of the Gaussian function is equal to 0.2 ns. The light pulse shape from the ternary plastics is described by the convolution integral of a Gaussian and two exponential functions. The Gaussian function presents the rate of energy transfer from nuclear particles to the primary solute as in the binary plastics. The exponential functions describe the energy transfer from the primary solute to the wavelength shifter and the final emission of the light. (Auth.)

  4. Topical methyl-aminolevulinate photodynamic therapy using red light-emitting diode light for treatment of multiple actinic keratoses: A randomized, double-blind, placebo-controlled study.

    Science.gov (United States)

    Pariser, David; Loss, Robert; Jarratt, Michael; Abramovits, William; Spencer, James; Geronemus, Roy; Bailin, Philip; Bruce, Suzanne

    2008-10-01

    The use of light-emitting diode light offers practical advantages in photodynamic therapy (PDT) with topical methyl-aminolevulinate (MAL) for management of actinic keratoses (AK). We sought to evaluate the efficacy of MAL PDT using red light-emitting diode light. We conducted a multicenter, double-blind, randomized study. A total of 49 patients with 363 AK lesions had 16.8% MAL cream applied under occlusion for 3 hours, and 47 patients with 360 AK lesions had vehicle cream similarly applied. The lesions were then illuminated (630 nm, light dose 37 J/cm2) with repeated treatment 1 week later. Complete lesion and patient (all lesions showing complete response) response rates were evaluated 3 months after last treatment. MAL PDT was superior (PAK. MAL PDT using red light-emitting diode light is an appropriate treatment alternative for multiple AK lesions.

  5. Design optimization of a compact photonic crystal microcavity based on slow light and dispersion engineering for the miniaturization of integrated mode-locked lasers

    Science.gov (United States)

    Kemiche, Malik; Lhuillier, Jérémy; Callard, Ségolène; Monat, Christelle

    2018-01-01

    We exploit slow light (high ng) modes in planar photonic crystals in order to design a compact cavity, which provides an attractive path towards the miniaturization of near-infrared integrated fast pulsed lasers. By applying dispersion engineering techniques, we can design structures with a low dispersion, as needed by mode-locking operation. Our basic InP SiO2 heterostructure is robust and well suited to integrated laser applications. We show that an optimized 30 μm long cavity design yields 9 frequency-equidistant modes with a FSR of 178 GHz within a 11.5 nm bandwidth, which could potentially sustain the generation of optical pulses shorter than 700 fs. In addition, the numerically calculated quality factors of these modes are all above 10,000, making them suitable for reaching laser operation. Thanks to the use of a high group index (28), this cavity design is almost one order of magnitude shorter than standard rib-waveguide based mode-locked lasers. The use of slow light modes in planar photonic crystal based cavities thus relaxes the usual constraints that tightly link the device size and the quality (peak power, repetition rate) of the pulsed laser signal.

  6. Design optimization of a compact photonic crystal microcavity based on slow light and dispersion engineering for the miniaturization of integrated mode-locked lasers

    Directory of Open Access Journals (Sweden)

    Malik Kemiche

    2018-01-01

    Full Text Available We exploit slow light (high ng modes in planar photonic crystals in order to design a compact cavity, which provides an attractive path towards the miniaturization of near-infrared integrated fast pulsed lasers. By applying dispersion engineering techniques, we can design structures with a low dispersion, as needed by mode-locking operation. Our basic InP SiO2 heterostructure is robust and well suited to integrated laser applications. We show that an optimized 30 μm long cavity design yields 9 frequency-equidistant modes with a FSR of 178 GHz within a 11.5 nm bandwidth, which could potentially sustain the generation of optical pulses shorter than 700 fs. In addition, the numerically calculated quality factors of these modes are all above 10,000, making them suitable for reaching laser operation. Thanks to the use of a high group index (28, this cavity design is almost one order of magnitude shorter than standard rib-waveguide based mode-locked lasers. The use of slow light modes in planar photonic crystal based cavities thus relaxes the usual constraints that tightly link the device size and the quality (peak power, repetition rate of the pulsed laser signal.

  7. Facilitation of decommissioning light water reactors

    International Nuclear Information System (INIS)

    Moore, E.B. Jr.

    1979-12-01

    Information on design features, special equipment, and construction methods useful in the facilitation of decommissioning light water reactors is presented. A wide range of facilitation methods - from improved documentation to special decommissioning tools and techniques - is discussed. In addition, estimates of capital costs, cost savings, and radiation dose reduction associated with these facilitation methods are given

  8. Integration of organic LEDs with inorganic LEDs for a hybrid lighting system

    Science.gov (United States)

    Kong, H. J.; Park, J. W.; Kim, Y. M.

    2013-01-01

    We demonstrate that a surface-emitting hybrid light source can be realized by a combination of organic and inorganic light-emitting devices (LEDs). To this end, a blue inorganic LED bar is deployed at one side of a transparent light guide plate (LGP), and a yellow organic LED (OLED) is in contact with the rear surface of the LGP. In such a configuration, it is found that the overall luminance is almost equivalent to the sum of the luminances measured from each light source, and the overall luminance uniformity is determined mainly by the luminance uniformity of the OLED panel at high luminances. We have achieved a white color showing the Commission Internationale d'Eclairage (CIE) chromaticity coordinates of (x = 0.34, y = 0.33), the power efficiency of 9.3 lm/W, the luminance uniformity of 63% at the luminance of 3100 cd m-2, the color rendering index as high as 89.3, and the correlated color temperature finely tunable within the range between 3000 and 8000 K. Such a system facilitates color tuning by adjusting their luminous intensities and hence the implementation of the emotional lighting system.

  9. Integration of organic LEDs with inorganic LEDs for a hybrid lighting system

    International Nuclear Information System (INIS)

    Kong, H J; Kim, Y M; Park, J W

    2013-01-01

    We demonstrate that a surface-emitting hybrid light source can be realized by a combination of organic and inorganic light-emitting devices (LEDs). To this end, a blue inorganic LED bar is deployed at one side of a transparent light guide plate (LGP), and a yellow organic LED (OLED) is in contact with the rear surface of the LGP. In such a configuration, it is found that the overall luminance is almost equivalent to the sum of the luminances measured from each light source, and the overall luminance uniformity is determined mainly by the luminance uniformity of the OLED panel at high luminances. We have achieved a white color showing the Commission Internationale d'Eclairage (CIE) chromaticity coordinates of (x = 0.34, y = 0.33), the power efficiency of 9.3 lm/W, the luminance uniformity of 63% at the luminance of 3100 cd m –2 , the color rendering index as high as 89.3, and the correlated color temperature finely tunable within the range between 3000 and 8000 K. Such a system facilitates color tuning by adjusting their luminous intensities and hence the implementation of the emotional lighting system. (paper)

  10. A thermo-degradable hydrogel with light-tunable degradation and drug release.

    Science.gov (United States)

    Hu, Jingjing; Chen, Yihua; Li, Yunqi; Zhou, Zhengjie; Cheng, Yiyun

    2017-01-01

    The development of thermo-degradable hydrogels is of great importance in drug delivery. However, it still remains a huge challenge to prepare thermo-degradable hydrogels with inherent degradation, reproducible, repeated and tunable dosing. Here, we reported a thermo-degradable hydrogel that is rapidly degraded above 44 °C by a facile chemistry. Besides thermo-degradability, the hydrogel also undergoes rapid photolysis with ultraviolet light. By embedding photothermal nanoparticles or upconversion nanoparticles into the gel, it can release the entrapped cargoes such as dyes, enzymes and anticancer drugs in an on-demand and dose-tunable fashion upon near-infrared light exposure. The smart hydrogel works well both in vitro and in vivo without involving sophisticated syntheses, and is well suited for clinical cancer therapy due to the high transparency and non-invasiveness features of near-infrared light. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. From Darwin to Internet at the speed of light

    Science.gov (United States)

    2002-11-01

    Data moving around the Internet are like road traffic in that a car can be driven fast down a straight road but has to slow down a great deal when changing direction at a junction. The same thing happens on information highways. Beams of light carry data along fibre-optic cables at very high speeds. When the data arrive at computers, known as servers, the servers redirect them to their final destinations. Presently, you need to convert the light signals into electricity, and that slows everything down. Electrons move at a speed of a few kilometres per second through a circuit, whereas light travels at nearly 300 000 kilometres per second. Integrated optics would leave the data as light and simply channel it through the chip, in the right direction. Scientists call this area integrated optics, referring to the integrated circuit board on which chips are mounted. Instead of miniaturised electronics, however, miniaturised optics are placed on a microchip. ESA has a strategy to enable more sophisticated searches for extra-solar planets in the future. Two planned developments rely on combining the light from such planets in a number of different telescopes. These are the Darwin mission and its precursor, the ESA/ESO Ground-based European Nulling Interferometer Experiment (GENIE). When you combine light beams, you traditionally need moving mirrors and lenses to divert the light beams to where you want them. However, if the system moves, it can break. As Malcolm Fridlund, Project Scientist for Darwin and GENIE says, “To change to integrated optics, which is much smaller and has no moving parts, would be highly desirable.” Desirable certainly, but also difficult. At present, integrated optics is a science that is far behind integrated circuit technology. For this reason, ESA is funding two studies. Astrium has been asked to study a traditional optics approach and Alcatel is investigating an integrated-optics solution. “We shall take the decision on whether GENIE will

  12. Repair of pyrimidine dimers in nuclear and mitochondrial DNA of yeast irradiated with low doses of ultraviolet light

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, L [Rochester Univ., N.Y. (USA). Dept. of Radiation Biology and Biophysics

    1975-01-01

    The repair of damage induced by ultraviolet light has been examined in both the nuclear and mitochondrial DNA of the yeast Saccharomyces cerevisiae. The sensitive assay used in this study is based on the capacity of the bacteriophage T4 u.v. endonuclease to produce single-strand breaks in DNA that contains pyrimidine dimers, thus permitting the use of low fluences (doses) of u.v. The results demonstrate that virtually all of the dimers induced in the nuclear DNA of a repair-proficient strain (RAD+) are removed following dark incubation for four hours in growth medium. In contrast, the dimers induced in mitochondrial DNA by the same u.v. fluence are retained under the same conditions. In the excision-deficient mutant, rad1-2, no evidence was obtained for removal of pyrimidine dimers from nuclear DNA. Photoreactivation of both RAD + and rad1-2 cultures resulted in decreases of dimers from both nuclear and mitochondrial DNA. It is concluded that an excision-repair mechanism operates on nuclear but not mitochondrial DNA in repair-proficient yeast, and that the rad1-2 mutant is defective in this process.

  13. SIGMA/B, Doses in Space Vehicle for Multiple Trajectories, Various Radiation Source

    International Nuclear Information System (INIS)

    Jordan, T.M.

    2003-01-01

    1 - Description of problem or function: SIGMA/B calculates radiation dose at arbitrary points inside a space vehicle, taking into account vehicle geometry, heterogeneous placement of equipment and stores, vehicle materials, time-weighted astronaut positions and many radiation sources from mission trajectories, e.g. geomagnetically trapped protons and electrons, solar flare particles, galactic cosmic rays and their secondary radiations. The vehicle geometry, equipment and supplies, and man models are described by quadric surfaces. The irradiating flux field may be anisotropic. The code can be used to perform simultaneous dose calculations for multiple vehicle trajectories, each involving several radiation sources. Results are presented either as dose as a function of shield thickness, or the dose received through designated outer sections of the vehicle. 2 - Method of solution: Automatic sectoring of the vehicle is performed by a Simpson's rule integration over angle; the dose is computed by a numerical angular integration of the dose attenuation kernels about the dose points. The kernels are curve-fit functions constructed from input data tables. 3 - Restrictions on the complexity of the problem: The code uses variable dimensioning techniques to store data. The only restriction on problem size is the available core storage

  14. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  15. Fallout, radiation doses near Dounreay, and childhood leukaemia

    International Nuclear Information System (INIS)

    Darby, S.C.; Doll, Richard

    1987-01-01

    Possible explanations for the recently reported increased incidence of childhood leukaemia around Dounreay were examined in the light of changes in the national incidence of leukaemia that occurred during the period of exposure to fallout from international testing of nuclear weapons in the atmosphere. It was concluded that the increase could not be accounted for by underestimate of the risk of leukaemia per unit dose of radiation at low doses and low dose rates, nor by underestimate of the relative biological efficiency of high compared with low linear energy transfer radiation. One possible explanation was underestimation of doses to the red bone marrow due to the discharges at Dounreay relative to dose from fallout, though investigation of ways in which this might have occurred did not suggest anything definite. Other explanations included a misconception of the site of origin of childhood leukaemia, outbreaks of an infectious disease and exposure to other, unidentified environmental agents. These findings weigh against the hypothesis that the recent increase in childhood leukaemia near Dounreay might be accounted for by radioactive discharges from nuclear plants, unless the doses to the stem cells from which childhood leukaemia originates have been grossly underestimated. (author)

  16. Lightswitch 2002 : a model for electric lighting and blind usage in single offices

    Energy Technology Data Exchange (ETDEWEB)

    Reinhart, C.F. [National Research Council of Canada, Ottawa, ON (Canada). Inst. for Research in Construction

    2003-04-03

    This report presents the Lightswitch 2002 model which predicts the electric lighting energy demand in private offices with manually and automatically controlled lighting and blind systems. Some basic behaviour patterns that define occupant interaction with lighting and blind controls were also identified and incorporated into the simulation tool called Lightswitch Wizard. This study studied integrated lighting control systems in 20 offices with a SSW orientation. Integrated lighting control systems coordinate the control of automated electric lights and blind systems with conventional building energy management systems. The benefits include a gain in occupant comfort and energy performance. It was concluded that Lightswitch 2002 has an advantage over former models in that each manual switching decision has a probability function assigned to it and a random process decides whether a switching event takes place or not. It was shown that the annual electric lighting energy demand for a manually controlled lighting and blind system can vary between 10 and 39 kWh/m{sup 2} per year for different user types. The model has some technical limitations concerning intermediate switch-off, thermal consideration, privacy issues, seating orientation and the location of controls. It was suggested that the model should be integrated with a thermal and lighting simulation tool in order to assess overall energy performance of different lighting and blind control strategies. refs., tabs., figs.

  17. White light coronagraph in OSO-7

    International Nuclear Information System (INIS)

    Koomen, M.J.; Detwiler, C.R.; Brueckner, G.E.; Cooper, H.W.; Tousey, R.

    1975-01-01

    A small, externally occulted Lyot-type coronagraph, designated for use in the seventh unmanned Orbiting Solar Observatory (OSO-7), is described. Optical configuration, suppression of stray light, SEC vidicon detector, and data system are discussed, as well as integration of the instrument into the spacecraft and operation in orbit. Orbital operation produced daily images of the white light corona, from 2.8 to 10 solar radii, at least once per day for 2 3/4 yr. The first records of white light coronal transient events were obtained, and the corona was shown to be constantly changing

  18. Sensitivity of the human circadian pacemaker to nocturnal light: melatonin phase resetting and suppression

    Science.gov (United States)

    Zeitzer, J. M.; Dijk, D. J.; Kronauer, R.; Brown, E.; Czeisler, C.

    2000-01-01

    Ocular exposure to early morning room light can significantly advance the timing of the human circadian pacemaker. The resetting response to such light has a non-linear relationship to illuminance. The dose-response relationship of the human circadian pacemaker to late evening light of dim to moderate intensity has not been well established. Twenty-three healthy young male and female volunteers took part in a 9 day protocol in which a single experimental light exposure6.5 h in duration was given in the early biological night. The effects of the light exposure on the endogenous circadian phase of the melatonin rhythm and the acute effects of the light exposure on plasma melatonin concentration were calculated. We demonstrate that humans are highly responsive to the phase-delaying effects of light during the early biological night and that both the phase resetting response to light and the acute suppressive effects of light on plasma melatonin follow a logistic dose-response curve, as do many circadian responses to light in mammals. Contrary to expectations, we found that half of the maximal phase-delaying response achieved in response to a single episode of evening bright light ( approximately 9000 lux (lx)) can be obtained with just over 1 % of this light (dim room light of approximately 100 lx). The same held true for the acute suppressive effects of light on plasma melatonin concentrations. This indicates that even small changes in ordinary light exposure during the late evening hours can significantly affect both plasma melatonin concentrations and the entrained phase of the human circadian pacemaker.

  19. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    Science.gov (United States)

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    Science.gov (United States)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.