WorldWideScience

Sample records for integrated leakage rate

  1. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  2. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  3. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  4. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  5. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  6. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  7. Time-dependent integral transport equation kernels, leakage rates and collision rates for plane and spherical geometry

    International Nuclear Information System (INIS)

    Henderson, D.L.

    1987-01-01

    Time-dependent integral transport equation flux and current kernels for plane and spherical geometry are derived for homogeneous media. Using the multiple collision formalism, isotropic sources that are delta distributions in time are considered for four different problems. The plane geometry flux kernel is applied to a uniformly distributed source within an infinite medium and to a surface source in a semi-infinite medium. The spherical flux kernel is applied to a point source in an infinite medium and to a point source at the origin of a finite sphere. The time-dependent first-flight leakage rates corresponding to the existing steady state first-flight escape probabilities are computed by the Laplace transform technique assuming a delta distribution source in time. The case of a constant source emitting neutrons over a time interval, Δt, for a spatially uniform source is obtained for a slab and a sphere. Time-dependent first-flight leakage rates are also determined for the general two region spherical medium problem for isotropic sources with a delta distribution in time uniformly distributed throughout both the inner and outer regions. The time-dependent collision rates due to the uncollided neutrons are computed for a slab and a sphere using the time-dependent first-flight leakage rates and the time-dependent continuity equation. The case of a constant source emitting neutrons over a time interval, Δt, is also considered

  8. In-depth analysis of eight criteria for integrated leakage rate tests for nuclear power plant containment buildings

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.F.; Lurie, D.

    1989-01-01

    A U.S. Nuclear Regulatory Commission (NRC) Small Business Innovation research (SBIR) Contract investigated ten integrated leakage rate test (ILRT) analysis models which have been proposed for evaluation of ILRT data. This contract involved in-depth analysis of two ILRTs with data collected at accelerated rates and 80 conventional ILRTs with data collected at a frequency between 10-15 minutes. All ten methods were applied to all data. The study considered the appropriateness of each method to analyze containment data (air mass versus time), the influence of data collection frequency on ILRT duration, and the influence of collection frequency on each method. The study is described in the paper. Results are presented

  9. Nuclear Power Plant Prestressed Concrete Containment Vessel Structure Monitoring during Integrated Leakage Rate Testing Using Fiber Bragg Grating Sensors

    Directory of Open Access Journals (Sweden)

    Jinke Li

    2017-04-01

    Full Text Available As the last barrier of nuclear reactor, prestressed concrete containment vessels (PCCVs play an important role in nuclear power plants (NPPs. To test the mechanical property of PCCV during the integrated leakage rate testing (ILRT, a fiber Bragg grating (FBG sensor was used to monitor concrete strain. In addition, a finite element method (FEM model was built to simulate the progress of the ILRT. The results showed that the strain monitored by FBG had the same trend compared to the inner pressure variation. The calculation results showed a similar trend compared with the monitoring results and provided much information about the locations in which the strain sensors should be installed. Therefore, it is confirmed that FBG sensors and FEM simulation are very useful in PCCV structure monitoring.

  10. Decision Analysis and Its Application to the Frequency of Containment Integrated Leakage Rate Tests

    International Nuclear Information System (INIS)

    Apostolakis, George E.; Koser, John P.; Sato, Gaku

    2004-01-01

    For nuclear utilities to become competitive in a deregulated electricity market, costs must be reduced, safety must be maintained, and interested stakeholders must remain content with the decisions being made. One way to reduce costs is to reduce the frequency of preventive maintenance and testing. However, these changes must be weighed against their impact on safety and stakeholder relations. We present a methodology that allows the evaluation of decision options using a number of objectives that include safety, economics, and stakeholder relations. First, the candidate decision options are screened to make sure that they satisfy the relevant regulatory requirements. The remaining options are evaluated using multiattribute utility theory. The results of the formal analysis include a ranking of the options according to their desirability as well as the major reasons that explain this ranking. These results are submitted to a deliberative process in which the decision makers scrutinize the results to ensure that they are meaningful. During the deliberation, new decision options may be formulated based on the insights that the formal analysis provides, as happened in the case study of this paper. This case study deals with the reduction in frequency of the containment integrated leak rate test of a boiling water reactor

  11. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  12. Nuclear power plant prestressed concrete containment vessel structure monitoring during integrated leakage rate test using three kinds of fiber optic sensors

    Science.gov (United States)

    Liao, Kaixing; Li, Jinke; Kong, Xianglong; Sun, Changsen; Zhao, Xuefeng

    2017-04-01

    After years of operation, the safety of the prestressed concrete containment vessel (PCCV) structure of Nuclear Power Plant (NPP) is an important aspect. In order to detect the strength degradation and the structure deformation, several sensors such as vibrating wire strain gauge, invar wires and pendulums were installed in PCCV. However, the amounts of sensors above are limited due to the cost. Due to the well durability of fiber optic sensors, three kinds of fiber optic sensors were chosen to install on the surface of PCCV to monitor the deformation during Integrated Leakage Rate Test (ILRT). The three kinds of fiber optic sensors which had their own advantages and disadvantages are Fiber Bragg Grating (FBG), white light interferometry (WLI) and Brillouin Optical Time Domain Analysis (BOTDA). According to the measuring data, the three fiber optic sensors worked well during the ILRT. After the ILRT, the monitoring strain was recoverable thus the PCCV was still in the elastic stage. If these three kinds of fiber optic sensors are widely used in the PCCV, the unusual deformations are easier to detect. As a consequence, the three fiber optic sensors have good potential in the structure health monitoring of PCCV.

  13. Secret rate - Privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.; Willems, F.M.J.

    2009-01-01

    Ahlswede and Csiszár [1993] introduced the concept of secret sharing. In their source model two terminals observe two correlated sequences. It is the objective of the terminals to form a common secret by interchanging a public message (helper data) in such a way that the secrecy leakage is

  14. Exchange-Rate Unification with Black Market Leakages; Russia 1992

    OpenAIRE

    Linda S. Goldberg

    1993-01-01

    In 1992 Russia unified the multiple exchange rates that had applied to international transactions. This paper describes the multiple exchange rate system that existed in Russia prior to mid-1992 and undertakes a theoretical exploration of the effects of the exchange rate unification that took place in July 1992. The model developed here allows for leakages between official and black markets and permits flexibility of the exchange rates in both official and parallel currency markets. Within th...

  15. Containment Leakage Rate Testing Program in NPP Krsko

    International Nuclear Information System (INIS)

    Dudas, M.; Heruc, Z.

    2002-01-01

    NPP Krsko adopted new regulations for testing of the reactor building containment as stipulated by 10CFR50 (Code of Federal Regulation) Appendix J, Option B instead of the previous requirement 10CFR50 Appendix J now renamed to 10CFR50 Appendix J, Option A. In the USA a thorough analyses of nuclear power plants reactor building containment testing was conducted. As part of these analyses the test results obtained from testing of various reactor-building containments in the last ten years were reviewed. It was concluded that it would be meaningful to, based on test results historical data, reconsider possibility of redefining testing intervals. The official proposal of such approach was reviewed and approved by the NRC and published in September of 1995 in the FR Vol.60 No.186. Based on directions from 10CFR50 Appendix J, Option B, the new criteria for definition of test intervals were created. Criteria were based upon past performance during testing (Performance-based Requirements) and safety impact. At NPP Krsko, the analyses of the Reactor Building Containment. Integrity Test results was performed . This included test results of the Containment Integrated Leak Rate Testing (CILRT or Type A tests), Containment Isolation Valves Local Leak Rater Tests (Type C tests) and Mechanical and Electrical Penetrations Local Leak Rate tests (Type B tests). In accordance with instructions from NEI 94-01 and based on analyses of test results, NPP Krsko created Containment Leakage Rate Testing Program with the purpose to establish the performance-based definition of test intervals, inspection scope, trending and reporting. Equally, the program gives instructions how to evaluate test results and how to deal with the containment penetration or isolation valve repair contingency. All changes caused with transition from Option A to Option B are marginal to public safety. (author)

  16. WWER steam generator tube structural and leakage integrity

    International Nuclear Information System (INIS)

    Splichal, K.; Krhounek, Vl.; Otruba, J.; Ruscak, M.

    1998-01-01

    The integrity of heat exchange tubes may influence the lifetime of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirements are to assure very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evaluation and heat exchange tubes plugging. The stress corrosion cracking and pitting are the main corrosion damages of WWER heat exchange tubes and are initiated from the outer surface. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through wall cracks, oriented preferentially in the axial direction. The paper presents the leakage and plugging limits for WWER steam generators, which have been determined from leak tests and burst tests. The tubes with axial part-through and through-wall defects have been used. The permissible value of primary to secondary leak rate was evaluated with respect to permissible axial through-wall defect size of WWER 440 and 1000 steam generator tubes. Blocking of the tube cracks by corrosion product particles and other compounds reduces the primary to secondary leak rate. The plugging limits involve the following factors: permissible tube wall thickness which determine further operation of the tubes with defects and assures their integrity under operating conditions and permissible size of a through-wall crack which is sufficiently stable under normal and accident conditions in relation to the critical crack length. For the evaluation of burst test of heat exchange tubes with longitudinal through-wall defects the instability criterion has been used and the dependence of the normalised burst pressure on the normalised length of an axial through-wall defect has been determined. The validity of the criterion of instability for WWER tubes with through

  17. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  18. Experiences in integrated leak rate measurements

    International Nuclear Information System (INIS)

    Shirk, R.E.

    1982-01-01

    During a hypothetical design basis accident for nuclear power plants, the reactor containment system is relied upon to maintain radioactive exposure limits below acceptable limits. Integrated leak rate testing is a means of verifying that the leakage of radioactivity material from the reactor containment will be below allowable limits. Leakage rate computations are based on the ideal gas law. The absolute method of leakage rate testing utilizing mass point method of data analysis is recommended. Integrated leak rate testing data is obtained from pressure, drybulb temperature, dewpoint temperature, and flow measuring systems. Test data does not support the usual leakage (flow) - pressure square root relationship. The major source of potential leakage from the reactor containment is reactor containment isolation valves

  19. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  20. Gas leakage rate through reinforced concrete shear walls: Numerical study

    International Nuclear Information System (INIS)

    Wang Ting; Hutchinson, Tara C.

    2005-01-01

    Unlined reinforced concrete shear walls are often used as 'tertiary boundaries' in the United States Department of Energy (DOE) to house dangerous gases. An unanticipated event, such as an earthquake, may cause gases stored inside the walls to disperse into the environment resulting in excess pollution. To address this concern, in this paper, a methodology to numerically predict the gas leakage rate through these shear walls under lateral loading conditions is proposed. This methodology involves finite element and flow rate analysis. Strain distributions are obtained from the finite element analysis, and then used to simulate the crack characteristics on the concrete specimen. The flow rate through the damaged concrete specimen is then estimated using flow rate formulas available from the literature. Results from an experimental specimen are used to evaluate the methodology, and particularly its robustness in the flow rate estimation

  1. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  2. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  3. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K.; Otruba, J. [Nuclear Research Inst., Rez (Switzerland)

    1997-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  4. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.

    1997-01-01

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction

  5. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K; Otruba, J [Nuclear Research Inst., Rez (Switzerland)

    1998-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  6. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  7. Penetration of gas into concrete during a leakage rate test of reactor containments and its significance for the drop in pressure

    Directory of Open Access Journals (Sweden)

    Nilsson L.-O.

    2011-04-01

    Full Text Available The objective of the project described in the paper was to develop a simulation model that describes transient air pressure distribution in concrete in order to see if the leakage rates obtained from the Containment Integrated Leakage Rate Tests can be explained by the transient air pressurization of concrete pores inside the steel liner. A partial differential equation was derived which describes transient air pressure distribution in concrete pores. The model was validated against experimental results. The simulation model shows that there are significant air fluxes into the concrete structures that can explain the pressure drop during a leakage test.

  8. Performance-based improvement of the leakage rate test program for the reactor containment of HTTR. Adoption of revised test programs containing 'Type A, Type B and Type C tests'

    International Nuclear Information System (INIS)

    Kondo, Masaaki; Emori, Koichi; Sekita, Kenji; Furusawa, Takayuki; Hayakawa, Masato; Kozawa, Takayuki; Aono, Tetsuya; Kuroha, Misao; Ouchi, Hiroshi; Kimishima, Satoru

    2008-10-01

    The reactor containment of HTTR is periodically tested to confirm leak-tight integrity by conducting overall integrated leakage rate tests, so-called 'Type A tests,' in accordance with a standard testing method provided in Japan Electric Association Code (JEAC) 4203. 'Type A test' is identified as a basic one for measuring whole leakage rates for reactor containments, it takes, however, much of cost and time of preparation, implementation and restoration of itself. Therefore, in order to upgrade the maintenance technology of HTTR, the containment leakage rate test program for HTTR was revised by adopting efficient and economical alternatives including Type B and Type C tests' which intend to measure leakage rates for containment penetrations and isolation valves, respectively. In JEAC4203-2004, following requirements are specified for adopting an alternative program: upward trend of the overall integrated leakage rate due to aging affection should not be recognized; performance criterion for combined leakage rate, that is a summation of local leakage rates evaluated by Type B and Type C tests and converted to whole leakage rates, should be established; the criterion of the combined leakage rate should be satisfied as well as of the overall integrated leakage rate; correlation between the overall integrated and combined leakage rates should be recognized. Considering the historical performances, policies of conforming to the forgoing requirements and of carrying out the revised test program were developed, which were accepted by the regulatory agency. This report presents an outline of the leakage rate tests for the reactor containment of HTTR, identifies practical issues of conventional Type A tests, and describes the conforming and implementing policies mentioned above. (author)

  9. Serial measurement of radiation leakage dose rates in safekeeping at the Gammaknife room

    International Nuclear Information System (INIS)

    Baba, Sadaaki; Nozaki, Kenichi; Toyoda, Tatsuya; Wakamatsu, Osamu; Machida, Toru

    2006-01-01

    We report the serial measurement of leakage dose rates in safekeeping at the Gammaknife room during the past 4 years and 9 months by scintillation survey meter. The leakage dose rates at the radiation boundaries were the same as the natural background levels. Leakage dose rates at each shield calculation point from two 90 Sr calibration sources contained in the storehouse were negligible compared with those from 60 Co sources of the Gammaknife. 60 Co sources of the Gammaknife are arranged in 201 pieces at 10 degree interval on the circumference and in five lines within an arc of 35 degrees. Its shield container is made of iron at least 43 cm thick. We got leakage dose rates less than 40% of the calculated values. We think it is caused by the difference of each actual distance and shield thickness because 60 Co sources are usually considered as a point source in the shield calculation. There are shutters opening up and down when patients go in and out to the direction of the couch. The leakage values to this direction were about twice as much as the calculated value. So, we knew the thickness of those shutters was thinner than 43 cm. The half life time of 60 Co source calculated from the serial measurements of leakage dose rates was 4.93 years on average. It is 94% of the physical half life value of 5.27 years. We judged it was acceptable considering the difficulty of measuring low dose rate level with the radiation survey meter. Very strong correlation was observed between the decrease of 60 Co dose rate acquired from one minute measurement at the center of 18 cm diameter polysterene phantom gotten from December 2000 to August 2005 and that of computation based on the physical half life time. Likewise there was strong and more correlation with leakage dose rate in the Gammaknife room. From this, we deduce the leakage dose rate decreases according to the theory of the disintegration of radioactivity with passage of time. Revised radiation related laws took effect

  10. Evaluation method of gas leakage rate from transportation casks of radioactive materials (gas leakage rates from scratches on O-ring surface)

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Li Ninghua; Asano, Ryoji; Kawa, Tsunemichi

    2004-01-01

    A sealing function is essential for transportation and/or storage casks of radioactive materials under both normal and accidental operating conditions in order to prevent radioactive materials from being released into the environment. In the safety analysis report, the release rate of radioactive materials into the environment is evaluated using the correlations specified in the ANSI N14.5, 1987. The purposes of the work are to reveal the underlying problems on the correlations specified in the ANSI N14.5 related to gas leakage rates from a scratch on O-ring surface and from multi-leak paths, to offer a data base to study the evaluation method of the leakage rate and to propose the evaluation method. In this paper, the following insights were obtained and clarified: 1. If a characteristic value of a leak path is defined as D 4 /a ('D' is the diameter and 'a' is the length), a scratch on the O-ring surface can be evaluated as a circular tube. 2. It is proper to use the width of O-ring groove on the flange as the leak path length for elastomer O-rings. 3. Gas leakage rates from multi leak paths of the transportation cask can be evaluated in the same manner as a single leak path if an effective D4/a is introduced. (author)

  11. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  12. Elements for computing and forecasting the leakage rate of the inner containment of nuclear reactor buildings

    International Nuclear Information System (INIS)

    Asali, M.; Capra, B.; Mazars, J.; Colliat, J.B.

    2015-01-01

    This study aims at introducing a methodology based on a macro-element discretization to compute and forecast the air leak rate of double-wall reactor buildings during air pressure tests. Assumptions at the basis of a weakly coupled strategy are checked in the case of a typical porous concrete section of an inner containment modeled during a 33 year period including four decennial regulatory pressure tests. However, air leakage due to porosity is only part of in situ measurements. Leakage due to cracking is another part and should be taken into account. A first macro-element is then presented, that superimposes Darcy flow within a porous matrix together with Poiseuille flow within a crack. Those elements are then used in a 3D hydraulic model to compute more accurately the total air leakage rate of considered structures. (authors)

  13. Electromagnetic Calculation and Plasma Leakage Rate Analysis of the Magnetically Confined Plasma Rocket

    International Nuclear Information System (INIS)

    Ni Zhipeng; Wang Liangbin; Li Jiangang; Chen Zhiyou; Zhang Yong; Wang Futang

    2008-01-01

    An electromagnetic calculation and the parameters of the magnet system of the magnetically confined plasma rocket were established. By using ANSYS code, it was found that the leakage rate depends on the current intensity of the magnet and the change of the magnet position.

  14. Effect of vadose zone on the steady-state leakage rates from landfill barrier systems

    International Nuclear Information System (INIS)

    Celik, B.; Rowe, R.K.; Unlue, K.

    2009-01-01

    Leakage rates are evaluated for a landfill barrier system having a compacted clay liner (CCL) underlain by a vadose zone of variable thickness. A numerical unsaturated flow model SEEP/W is used to simulate the moisture flow regime and steady-state leakage rates for the cases of unsaturated zones with different soil types and thicknesses. The results of the simulations demonstrate that harmonic mean hydraulic conductivity of coarse textured vadose zones is 3-4 orders of magnitude less than saturated hydraulic conductivity; whereas, the difference is only one order of magnitude for fine textured vadose zones. For both coarse and fine textured vadose zones, the effective hydraulic conductivity of the barrier system and the leakage rate to an underlying aquifer increases with increasing thickness of the vadose zone and ultimately reaches an asymptotic value for a coarse textured vadose zone thickness of about 10 m and a fine textured vadose zone thickness of about 5 m. Therefore, the fine and coarse textured vadose zones thicker than about 5 m and 10 m, respectively, act as an effective part of the barrier systems examined. Although the thickness of vadose zone affects the effective hydraulic conductivity of the overall barrier system, the results demonstrated that the hydraulic conductivity of the CCL is the dominant factor controlling the steady-state leakage rates through barrier systems having single low permeability clay layers

  15. Analytical methods of leakage rate estimation from a containment under a LOCA

    International Nuclear Information System (INIS)

    Chun, M.H.

    1981-01-01

    Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from then mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than the mass leakage rate formula of CONTEMPT-LT. (author)

  16. Integrated experimental and modeling assessment of potential effects of gas leakages on groundwater composition

    Science.gov (United States)

    Berta, Marton; Dethlefsen, Frank; Ebert, Markus; Schäfer, Dirk

    2017-04-01

    Storing renewably produced energy is one of the major challenges for the energy systems of the upcoming decades. Power-to-gas technologies coupled to geological storage of compressed air, methane, and hydrogen offer a comparatively safe and cost-efficient way for large-scale energy storage. However, the stored gases can potentially escape from their geological reservoir and may thus affect protected natural goods such as groundwater. The geochemical reactions responsible for these composition changes are usually investigated separately in experiments and numerical models. Here we present the outcomes of an integrated experimental and modeling approach through the example of a compressed air leakage scenario. A main consequence of the presence of oxygen to be assessed in an aquifer is pyrite oxidation, well known from acid mine drainage sites. However, in contrast to acid mine drainage sites exhibiting unsaturated sediments and fed by meteoric low-carbonate water, aquifers such as in Northern Germany contain a considerable amount of solid and dissolved inorganic carbon species potentially buffering pH changes. High pressure flow-through column experiments representing an intrusion of compressed air into an aquifer were carried out to quantify pyrite oxidation kinetics and to incorporate the observations into a descriptive reaction model. Surface passivation was found to decrease the reactivity of pyrite by more than 90% after a few months of experimental run time. We propose that the carbonate buffer system enables the precipitation of a passivating mineral layer on the pyrite surface reducing the overall reaction rate significantly. Consequently, an established rate law from the literature was extended by a reactive surface passivation term[1]. This improved reaction rate equation was incorporated into a 3D numerical model using OpenGeoSys with parameters representing similarly typical aquifer conditions the experiments had characterized. These boundaries include

  17. Limitation of leakage rate measurement sensitivity; Limitation de la sensibilite des mesures de debit de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Paigne, Jacques [Commissariat a l' energie atomique et aux energies alternatives - CEA, Services de Physique Appliquee (France)

    1964-08-15

    This note reports an experimental study which aimed at determining to which extent an enclosure degassing could affect the sensitivity of a helium detection cell because of an increased background noise. The author first describes the measurement method and the helium partial pressure measurement method. He then reports an application to leakage rate measurements, and discusses the influence of background noise (influence of degassing, and influence of atmospheric air)

  18. Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit

    Institute of Scientific and Technical Information of China (English)

    Ding Lili; Guo Hongxia; Chen Wei; Fan Ruyu

    2012-01-01

    Radiation-induced inter-device leakage is studied using an analytical model and TCAD simulation.There were some different opinions in understanding the process of defect build-up in trench oxide and parasitic leakage path turning on from earlier studies.To reanalyze this problem and make it beyond argument,every possible variable is considered using theoretical analysis,not just the change of electric field or oxide thickness independently.Among all possible inter-device leakage paths,parasitic structures with N-well as both drain and source are comparatively more sensitive to the total dose effect when a voltage discrepancy exists between the drain and source region.Since N-well regions are commonly connected to the same power supply,these kinds of structures will not be a problem in a real CMOS integrated circuit.Generally speaking,conduction paths of inter-device leakage existing in a real integrated circuit and under real electrical circumstances are not very sensitive to the total ionizing dose effect.

  19. Leakage rate from LOCA-aged inflatable airlock seals Pickering NGS 'B' personnel doors

    International Nuclear Information System (INIS)

    Fayle, G.W.; Cordingley, D.C.

    1985-01-01

    In order to demonstrate to the Atomic Energy Control Board that an air-lock inflatable seal will function after a LOCA exposure, an inflatable seal intended for personnel doors at the Pickering NGS 'B' was exposed to the thermal/moisture conditions of the LOCA requirement. While attending to determine the post-LOCA leakage rate it was found that additional leaks developed during each post-LOCA inflation/deflation cycle. The seal had been significantly and irreparably deteriorated by the LOCA exposure. The test has demonstrated that this type of LOCA exposed seal should not be expected to withstand either additional pressure above 207 kPa or additional inflation/deflation cycling. A higher inflation pressure and/or cycling will reduce the likelihood of a post-LOCA seal retaining an inflation pressure sufficient to prevent leakage across the seal

  20. Investigation of primary-to-secondary leakage accident on the PSB-VVER integral test facility

    International Nuclear Information System (INIS)

    Lipatov, I.A.; Dremin, G.I.; Galtchanskaya, S.A.; Chmal, I.I.; Moloshnikov, A.S.; Gorbunov, Y.S.; Antonova, A.I.; Elkin, I.V.

    2001-01-01

    The full text follows. The paper presents the main results from the test on primary-to-secondary leakage of 100 mm in equivalent diameter. The test was performed on the PSB-VVER integral test facility. PSB-VVER is a 4-loops scaled down model of primary system of NPP with VVER-1000 Russian type reactor. Volume - power scale is about 1/300 while elevation scale is 1/1. All components of the primary system of the reference NPP are modeled on PSB-VVER. Both passive (accumulators) and active (high and low pressure) ECCSs, pressurizer spray and relief circuits, feed water system and atmospheric dumping system (ADS) as well as the primary circuit gas remove emergency system are also simulated. The primary-to-secondary leakage was simulated using an external break line which connects the upper part of the hot header to SG water volume. The break line included a break nozzle (a cylindrical channel d = 5.8 mm, l/d = 10 with sharp inlet edge), quick-acting valve and two-phase mass flow rate measurement system. In addition loss of off-site power at the moment when a scram-signal is generated was assumed in the experiment. Thus the accident is to be considered as a beyond-design-basic one. The loss of off-site power results in the following: -main circulation pump shutdown; -pressurizer heaters switching off; -HPIS water cooling flow rate and number of points of water injection are reduced The study focuses on the adequacy of the associated accident management (AM) procedure developed by EDO ''GIDROPRESS'' as a General Designer of VVER-type reactors. The AM-procedure was adopted to the PSB-VVER test facility conditions using CATHARE (France) and DINAMIKA (Russia) codes analysis. The AM-procedure in PSB-VVER is as follows: after about 30 min of the onset of the accident, when the accident type and the localization of the SG affected become evident for the operator, he closes all the main steam isolation valves, inhibits the ADS actuation in the affected SG and begins to remove

  1. Investigation of primary-to-secondary leakage accident on the PSB-VVER integral test facility

    Energy Technology Data Exchange (ETDEWEB)

    Lipatov, I.A.; Dremin, G.I.; Galtchanskaya, S.A.; Chmal, I.I.; Moloshnikov, A.S.; Gorbunov, Y.S.; Antonova, A.I. [Electrogorsk Research and Engineering Center, EREC, Moscow (Russian Federation); Elkin, I.V. [RRC ' ' Kurchatov Institute, Moscow (Russian Federation)

    2001-07-01

    The full text follows. The paper presents the main results from the test on primary-to-secondary leakage of 100 mm in equivalent diameter. The test was performed on the PSB-VVER integral test facility. PSB-VVER is a 4-loops scaled down model of primary system of NPP with VVER-1000 Russian type reactor. Volume - power scale is about 1/300 while elevation scale is 1/1. All components of the primary system of the reference NPP are modeled on PSB-VVER. Both passive (accumulators) and active (high and low pressure) ECCSs, pressurizer spray and relief circuits, feed water system and atmospheric dumping system (ADS) as well as the primary circuit gas remove emergency system are also simulated. The primary-to-secondary leakage was simulated using an external break line which connects the upper part of the hot header to SG water volume. The break line included a break nozzle (a cylindrical channel d = 5.8 mm, l/d = 10 with sharp inlet edge), quick-acting valve and two-phase mass flow rate measurement system. In addition loss of off-site power at the moment when a scram-signal is generated was assumed in the experiment. Thus the accident is to be considered as a beyond-design-basic one. The loss of off-site power results in the following: -main circulation pump shutdown; -pressurizer heaters switching off; -HPIS water cooling flow rate and number of points of water injection are reduced The study focuses on the adequacy of the associated accident management (AM) procedure developed by EDO ''GIDROPRESS'' as a General Designer of VVER-type reactors. The AM-procedure was adopted to the PSB-VVER test facility conditions using CATHARE (France) and DINAMIKA (Russia) codes analysis. The AM-procedure in PSB-VVER is as follows: after about 30 min of the onset of the accident, when the accident type and the localization of the SG affected become evident for the operator, he closes all the main steam isolation valves, inhibits the ADS actuation in the affected SG

  2. Pre-operational proof and leakage rate testing requirements for concrete containment structures for CANDU nuclear power plants

    International Nuclear Information System (INIS)

    1994-02-01

    This Standard provides the requirements for pre-operational proof tests and leakage rate tests of concrete containment structures of a containment system designed as Class Containment components. 1 fig

  3. Quantifying canal leakage rates using a mass-balance approach and heat-based hydraulic conductivity estimates in selected irrigation canals, western Nebraska, 2007 through 2009

    Science.gov (United States)

    Hobza, Christopher M.; Andersen, Michael J.

    2010-01-01

    The water supply in areas of the North Platte River Basin in the Nebraska Panhandle has been designated as fully appropriated or overappropriated by the Nebraska Department of Natural Resources (NDNR). Enacted legislation (Legislative Bill 962) requires the North Platte Natural Resources District (NPNRD) and the NDNR to develop an Integrated Management Plan (IMP) to balance groundwater and surface-water supply and demand in the NPNRD. A clear understanding of the groundwater and surface-water systems is critical for the development of a successful IMP. The primary source of groundwater recharge in parts of the NPNRD is from irrigation canal leakage. Because canal leakage constitutes a large part of the hydrologic budget, spatially distributing canal leakage to the groundwater system is important to any management strategy. Surface geophysical data collected along selected reaches of irrigation canals has allowed for the spatial distribution of leakage on a relative basis; however, the actual magnitude of leakage remains poorly defined. To address this need, the U.S. Geological Survey, in cooperation with the NPNRD, established streamflow-gaging stations at upstream and downstream ends from two selected canal reaches to allow a mass-balance approach to be used to calculate daily leakage rates. Water-level and sediment temperature data were collected and simulated at three temperature monitoring sites to allow the use of heat as a tracer to estimate the hydraulic conductivity of canal bed sediment. Canal-leakage rates were estimated by applying Darcy's Law to modeled vertical hydraulic conductivity and either the estimated or measured hydraulic gradient. This approach will improve the understanding of the spatial and temporal variability of canal leakage in varying geologic settings identified in capacitively coupled resistivity surveys. The high-leakage potential study reach of the Tri-State Canal had two streamflow-gaging stations and two temperature monitoring

  4. Experimental study of the leakage rate through cracked reinforced concrete wall elements for defining the functional failure criteria of containment buildings

    International Nuclear Information System (INIS)

    Choun, Young Sun; Cho, Nam So

    2004-01-01

    Containment buildings in nuclear power plants should maintain their structural safety as well as their functional integrity during an operation period. To maintain the functional integrity, the wall and dome of the containment buildings have to maintain their air tightness under extreme loading conditions such as earthquakes, missile impact, and severe accidents. For evaluating the functional failure of containments, it is important to predict the leak amount through cracked concrete walls. The leakage through concrete cracks has been studied since 1972. Buss examined the flow rate of air through a pre-existing crack in a slab under air pressure. Rizkalla el al. initiated an experimental study for the leakage of prestressed concrete building segments under uniaxial and biaxial loadings to simulate the loading condition of containment buildings under an internal pressure. Recently, Salmon el al. initiated an experimental program for determining the leak rates in typical reinforced concrete shear walls subjected to beyond design basis earthquakes. This study investigates the cracking behavior of reinforced concrete containment wall elements under a uniaxial tension and addresses the outline of the leakage test for unlined containment wall elements

  5. SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States); Chu, A [Yale New Haven Hospital, New Haven, CT (United States); Chi, Y [Winter Park Cancer Center, Winter Park, FL (United States); Hu, J [Wayne State University, Detroit, MI (United States)

    2014-06-15

    Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

  6. A CFD method to evaluate the integrated influence of leakage and bypass flows on the PBMR Reactor Unit

    International Nuclear Information System (INIS)

    Janse van Rensburg, J.J.; Kleingeld, M.

    2010-01-01

    Research highlights: → Research and analysis to identify and rank different leakage flow paths in a HTR. → Development of integrated CFD methodology for the prediction of leakage flows. → Development of a methodology to simulate flow resistances in above CFD model. → Validation of predicted flow results against different numerical methodology. → Illustration of the significant improvement achieved through this methodology. - Abstract: An area that has been identified as significantly important in the development of a High Temperature Reactor (HTR) is the prediction of leakage and bypass flows through such a reactor. It is therefore essential to understand the causes of bypass flows and to determine the effect on the predicted fuel and component temperatures. This paper discusses the identification of leakage flows that are applicable to the Pebble Bed Modular Reactor (Pty) Ltd. (PBMR) design and the ranking of these leakage flows. The modeling methodology and results are also discussed. Similar to previous HTR's, it was found that leakage and bypass flows are important parameters to consider for safe and efficient operation of the PBMR. Through a focused approach, it is shown that PBMR is able to improve the understanding of this phenomenon and quantify the flows and subsequent influence on the operation of the system. This has resulted in a reduction of leakage and bypass from approximately 46% to 20%. The improved understanding of leakage and bypass flows allows PBMR to address this issue during the design phase of the project, which subsequently results in a vast improvement over historical HTR designs. This gives PBMR a distinct advantage over previous High Temperature Reactors.

  7. Study on leakage rates of high temperature water from wet-type transport casks for spent fuel. Pt. 2. Leakage rates from a scratch on O-ring surface and narrow wires adhering to O-ring surface

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Sudi, A.; Kohketsu, Y.

    1997-01-01

    A programme for enhancement of fuel burnup has been promoted in Japan as part of the sophisticated programme for light water reactors to reduce the fuel cost and the amount of spent fuel. As part of this fuel programme, a new wet-type transport cask has been developed to transport the high burnup fuels efficiently. The purpose of this work is to clarify the margin of safety in the evaluation of the release rate of radioactive materials from the wet-type transport cask into the environment and to establish a practical evaluation method for leakage rates on leak behaviour of high temperature water from the casks. In this paper, leakage rates of water under high pressures and at high temperatures are investigated from two kinds of leak path model. One is a disc with a scratch on the surface which simulates a defect on the seal surface of the O-ring flange and the other is narrow stainless steel wires installed on the O-ring surface which simulates hair adhering to the O-ring surface. From the results, an evaluation method for the leakage rate of water under high pressure and at high temperature from a non-circular leak path and multiple leak paths is proposed. (author)

  8. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, R.; Harrell, J.

    1996-12-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves.

  9. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    International Nuclear Information System (INIS)

    Fuller, R.; Harrell, J.

    1996-01-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves

  10. A new sensor for detection of coolant leakage in nuclear power plants using off-axis integrated cavity output spectroscopy

    International Nuclear Information System (INIS)

    Lee, Lim; Park, Hyunmin; Kim, Taek-Soo; Ko, Kwang-Hoon; Jeong, Do-Young

    2012-01-01

    A new sensor based on laser absorption spectroscopy was developed for the detection of coolant leakage which may happen in pressurized heavy water reactor (PHWR). Off-axis integrated output spectroscopy (OA-ICOS) technique was adopted for developing a simple and robust sensor with sufficient sensitivity. Leak events could be monitored by detecting a small change in semi-heavy water (HDO) concentration induced by the exchange reaction of leaked heavy water (D 2 O) with light water (H 2 O). From the results of feasibility tests, we have shown that the measured area of absorption features was linearly correlated with HDO concentration, and the minimum detectable change of HDO concentration with the developed sensor was evaluated as 3.2 ppm. This new sensor is expected to be a reliable and promising device for the detection of coolant leakage since it has some advantages on real-time monitoring and early detection for nuclear safety.

  11. On the calculation of leakage rates from vessels filled with high density gaseous CO2 using pressure drop data

    International Nuclear Information System (INIS)

    George, A.F.

    1987-09-01

    This paper considers calculation methods to estimate leakage rates from pressure drop data from vessels filled with high pressure (40 bar) low temperature (25 0 C) CO 2 . It is essential to consider the non-ideality of CO 2 under these conditions if accurate results are to be obtained. There are two main areas where this is relevant: the first is the use of temperature measurements to adjust the measured pressure readings so that the effect of temperature fluctuations is eliminated. The second is in the conversion of the pressure drop data to volumetric leak rate. An example test is described in which it is shown that the CO 2 based temperature correction method improves the accuracy of the pressure drop estimate by about a factor of ten over using a perfect gas assumption and a factor of about 25 over not attempting to adjust the pressure at all. Also the flow rate obtained from assuming the gas was perfect was almost a factor of two too low. A method for scaling leakage rates to other temperature pressures and gases is also given brief consideration in this report. It is observed that the results of scaling are strongly dependent on the flow regime assumed and it is not possible to determine the flow regime from the pressure drop data. Consequently only upper and lower bounds to the scaled estimate can be quoted. (U.K.)

  12. Integrating Flexible Sensor and Virtual Self-Organizing DC Grid Model With Cloud Computing for Blood Leakage Detection During Hemodialysis.

    Science.gov (United States)

    Huang, Ping-Tzan; Jong, Tai-Lang; Li, Chien-Ming; Chen, Wei-Ling; Lin, Chia-Hung

    2017-08-01

    Blood leakage and blood loss are serious complications during hemodialysis. From the hemodialysis survey reports, these life-threatening events occur to attract nephrology nurses and patients themselves. When the venous needle and blood line are disconnected, it takes only a few minutes for an adult patient to lose over 40% of his / her blood, which is a sufficient amount of blood loss to cause the patient to die. Therefore, we propose integrating a flexible sensor and self-organizing algorithm to design a cloud computing-based warning device for blood leakage detection. The flexible sensor is fabricated via a screen-printing technique using metallic materials on a soft substrate in an array configuration. The self-organizing algorithm constructs a virtual direct current grid-based alarm unit in an embedded system. This warning device is employed to identify blood leakage levels via a wireless network and cloud computing. It has been validated experimentally, and the experimental results suggest specifications for its commercial designs. The proposed model can also be implemented in an embedded system.

  13. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  14. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  15. Integrated Monitoring and Modeling of Carbon Dioxide Leakage Risk Using Remote Sensing, Ground-Based Monitoring, Atmospheric Models and Risk-Indexing Tools

    Science.gov (United States)

    Burton, E. A.; Pickles, W. L.; Gouveia, F. J.; Bogen, K. T.; Rau, G. H.; Friedmann, J.

    2006-12-01

    Correct assessment of the potential for CO2 leakage to the atmosphere or near surface is key to managing the risk associated with CO2 storage. Catastrophic, point-source leaks, diffuse seepage, and low leakage rates all merit assessment. Smaller leaks may be early warnings of catastrophic failures, and may be sufficient to damage natural vegetation or crops. Small leaks also may lead to cumulative build-up of lethal levels of CO2 in enclosed spaces, such as basements, groundwater-well head spaces, and caverns. Working with our ZERT partners, we are integrating a variety of monitoring and modeling approaches to understand how to assess potential health, property and environmental risks across this spectrum of leakage types. Remote sensing offers a rapid technique to monitor large areas for adverse environmental effects. If it can be deployed prior to the onset of storage operations, remote sensing also can document baseline conditions against which future claims of environmental damage can be compared. LLNL has been using hyperspectral imaging to detect plant stress associated with CO2 gas leakage, and has begun investigating use of NASA's new satellite or airborne instrumentation that directly measures gas compositions in the atmosphere. While remote sensing techniques have been criticized as lacking the necessary resolution to address environmental problems, new instruments and data processing techniques are demonstrated to resolve environmental changes at the scale associated with gas-leakage scenarios. During the shallow low-flow- CO2 release field experiments planned by ZERT, for the first time, we will have the opportunity to ground- truth hyperspectral data by simultaneous measurement of changes in hyperspectral readings, soil and root zone microbiology, ambient air, soil and aquifer CO2 concentrations. When monitoring data appear to indicate a CO2 leakage event, risk assessment and mitigation of that event requires a robust and nearly real-time method for

  16. Detection of concrete dam leakage using an integrated geophysical technique based on flow-field fitting method

    Science.gov (United States)

    Dai, Qianwei; Lin, Fangpeng; Wang, Xiaoping; Feng, Deshan; Bayless, Richard C.

    2017-05-01

    An integrated geophysical investigation was performed at S dam located at Dadu basin in China to assess the condition of the dam curtain. The key methodology of the integrated technique used was flow-field fitting method, which allowed identification of the hydraulic connections between the dam foundation and surface water sources (upstream and downstream), and location of the anomalous leakage outlets in the dam foundation. Limitations of the flow-field fitting method were complemented with resistivity logging to identify the internal erosion which had not yet developed into seepage pathways. The results of the flow-field fitting method and resistivity logging were consistent when compared with data provided by seismic tomography, borehole television, water injection test, and rock quality designation.

  17. Releasable activity and maximum permissible leakage rate within a transport cask of Tehran Research Reactor fuel samples

    Directory of Open Access Journals (Sweden)

    Rezaeian Mahdi

    2015-01-01

    Full Text Available Containment of a transport cask during both normal and accident conditions is important to the health and safety of the public and of the operators. Based on IAEA regulations, releasable activity and maximum permissible volumetric leakage rate within the cask containing fuel samples of Tehran Research Reactor enclosed in an irradiated capsule are calculated. The contributions to the total activity from the four sources of gas, volatile, fines, and corrosion products are treated separately. These calculations are necessary to identify an appropriate leak test that must be performed on the cask and the results can be utilized as the source term for dose evaluation in the safety assessment of the cask.

  18. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  19. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  20. Integrated Framework for Assessing Impacts of CO₂ Leakage on Groundwater Quality and Monitoring-Network Efficiency: Case Study at a CO₂ Enhanced Oil Recovery Site.

    Science.gov (United States)

    Yang, Changbing; Hovorka, Susan D; Treviño, Ramón H; Delgado-Alonso, Jesus

    2015-07-21

    This study presents a combined use of site characterization, laboratory experiments, single-well push-pull tests (PPTs), and reactive transport modeling to assess potential impacts of CO2 leakage on groundwater quality and leakage-detection ability of a groundwater monitoring network (GMN) in a potable aquifer at a CO2 enhanced oil recovery (CO2 EOR) site. Site characterization indicates that failures of plugged and abandoned wells are possible CO2 leakage pathways. Groundwater chemistry in the shallow aquifer is dominated mainly by silicate mineral weathering, and no CO2 leakage signals have been detected in the shallow aquifer. Results of the laboratory experiments and the field test show no obvious damage to groundwater chemistry should CO2 leakage occur and further were confirmed with a regional-scale reactive transport model (RSRTM) that was built upon the batch experiments and validated with the single-well PPT. Results of the RSRTM indicate that dissolved CO2 as an indicator for CO2 leakage detection works better than dissolved inorganic carbon, pH, and alkalinity at the CO2 EOR site. The detection ability of a GMN was assessed with monitoring efficiency, depending on various factors, including the natural hydraulic gradient, the leakage rate, the number of monitoring wells, the aquifer heterogeneity, and the time for a CO2 plume traveling to the monitoring well.

  1. 76 FR 48159 - Integrated System Power Rates

    Science.gov (United States)

    2011-08-08

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates AGENCY... American Electric Reliability Corporation and to cover increased investments and replacements in..., prepared a Current Power Repayment Study using existing system rates. The Study indicates that Southwestern...

  2. Gross Containment Leakage Monitoring System (GCLM) applied to accidental impairment of containment integrity determination

    International Nuclear Information System (INIS)

    Dinu, Camelia; Talpalariu, A.; Constantinescu, G.

    2007-01-01

    The Prioritization of Generic Safety Issues (NUREG-0933 of October 2006), section 1 task II.E.4 item II.E.4.3 recommends that a method of periodic or continuous testing has to be available, in order to detect unknown gross openings in the nuclear power plants containment structure. The Palisades incident and three other incidents are exemplified, when the reactor was operated for about 1.5 years, while the containment isolation valves in a purge system bypass line were unknowingly locked in the open position. It was estimated that the presence of a GCLM system could identify an unknown breach and reduce the expected unavailability of containment due to containment integrity breach events, to a 1.6x10 -3 /year demand. (authors)

  3. Assessment of structural integrity of Monju steel liner against sodium leakage and combustion. Strain criterion of the liner material

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, T.; Koi, M. [Japan Nuclear Cycle Development Institute, Ibaraki (Japan)

    2001-07-01

    In a postulated condition of sodium leakage and combustion in the secondary heat transfer system of the prototype Japanese fast breeder reactor Monju, thermal stresses raise in steel liners installed to prevent sodium from contacting to concrete. Excessive strain due to the thermal stresses leads to failure of the liner. This paper proposes a strain criterion below that the mechanical integrity of liner is assured. In-plane thermal expansion causes membrane strain and out-of-plane expansion causes bending strain. Therefore, failure modes to be taken into account are tensile fracture and bending fracture. The strain criterion can be determined based on tensile and bending tests. Tensile tests and three-point bending tests were performed at the temperature range from room temperature to 1000 C. Fracture elongation was measured in both tests. Uniform elongation was also measured in tensile tests. Various factors that can affect the above experimental results, multi-axiality, environmental effects, and creep were examined. Based on the above results, the strain criterion was determined. The criterion is 10% for membrane strain and 30% for membrane plus bending strain in the temperature range of 350 C to 1000 C. For the temperatures less than 350 C, the half of those values is used. (author)

  4. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  5. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  6. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  7. SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, keff, and α Using PARTISN

    Energy Technology Data Exchange (ETDEWEB)

    Favorite, Jeffrey A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-11-21

    SENSMG is a tool for computing first-order sensitivities of neutron reaction rates, reaction-rate ratios, leakage, keff, and α using the PARTISN multigroup discrete-ordinates code. SENSMG computes sensitivities to all of the transport cross sections and data (total, fission, nu, chi, and all scattering moments), two edit cross sections (absorption and capture), and the density for every isotope and energy group. It also computes sensitivities to the mass density for every material and derivatives with respect to all interface locations. The tool can be used for one-dimensional spherical (r) and two-dimensional cylindrical (r-z) geometries. The tool can be used for fixed-source and eigenvalue problems. The tool implements Generalized Perturbation Theory (GPT) as discussed by Williams and Stacey. Section II of this report describes the theory behind adjoint-based sensitivities, gives the equations that SENSMG solves, and defines the sensitivities that are output. Section III describes the user interface, including the input file and command line options. Section IV describes the output. Section V gives some notes about the coding that may be of interest. Section VI discusses verification, which is ongoing. Section VII lists needs and ideas for future work. Appendix A lists all of the input files whose results are presented in Sec. VI.

  8. Determining of leakage rate of radionuclides Co-60 and Cs-137 in real conditioning; Odredjivanje brzine procurivanja radionuklida Co-60 i Cs-137 u realnim uslovima

    Energy Technology Data Exchange (ETDEWEB)

    Plecas, I; Peric, A; Kostadinovic, A [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia)

    1989-07-01

    In this paper, results of examination of LEAKAGE rate of radionuclides Co-60 and Cs-137 in real condition are given. Radionuclides Co-60 and Cs-137 were immobilized by cement process and conditioned in concrete containers trying to make similar scenario for repository of radioactive waste materials as in engineering trench systems. Experiments were realized with evaporator bottom concentrate (EB) from Nuclear Power Plant Krsko in which the main radionuclides are Co-60 and Cs-137. (author)

  9. Reaction Order Ambiguity in Integrated Rate Plots

    Science.gov (United States)

    Lee, Joe

    2008-01-01

    Integrated rate plots are frequently used in reaction kinetics to determine orders of reactions. It is often emphasised, when using this methodology in practice, that it is necessary to monitor the reaction to a substantial fraction of completion for these plots to yield unambiguous orders. The present article gives a theoretical and statistical…

  10. A concern about the crack propagation rate of PWSCC which obtained from the investigation on primary coolant leakage portion of the reactor vessel head in Ohi 3

    International Nuclear Information System (INIS)

    Totsuka, Nobuo; Fukumura, Takuya

    2010-01-01

    There will be some concern about the content presented in the paper entitled 'Primary Coolant Leakage Path Research of Reactor Vessel Head Penetration' published in INSS JOURNAL of 2008, which may lead to misunderstanding about the PWSCC crack propagation rate, that is, the rate written in the paper seems to be faster than those reported by the previous studies. It is considered that such misunderstanding will be due to a sentence in the abstract of the paper. Therefore, we will revise a part of the abstract and explain about the outline of the paper again. (author)

  11. NEK containment integrated leak rate test at full pressure

    International Nuclear Information System (INIS)

    Skaler, F.; Planinc, V.; Gregoric, D.; Cicvaric, D.

    1999-01-01

    NPP Krsko is a Pressure Water Reactor (PWR) Plant which has four barriers to prevent release of radioactive fission products. These four barriers are following: Fuel itself, Fuel Clad, Reactor Coolant System and Containment Building. Containment is the last barrier which can prevent release of fission product when other barriers have been already broken. To find out the real condition of containment vessel and to prove its ability of withstanding increased parameters during accident we have to perform Containment Integrated Leak Rate Test at least three times in every ten years of operation. CILRT 1999 in NPP Krsko was completely performed following regulation of 10CFR50 App. J Option A and ANSI/ANS 56.8-1987. The main goal of CILRT is to prove that the leakage of containment pathways and wall structures are within limits prescribed in Technical Specifications by pressurization of containment building above peak accident pressure Pa and measuring the mass changes of air using Ideal Gas Law.(author)

  12. In-Pile Loop Safety in Integrated with the Multipurpose Reactor in the case of in-Pile Loop Leakage at the Core Position

    International Nuclear Information System (INIS)

    Suharno; Sugianto; Giarno; Aliq; Widodo, Surip; Aji, Bintoro; Purba, Julwan Hendry; Karyanta, Edy

    1999-01-01

    In-Pile Loop Safety analysis in integrated with the multipurpose reactor in the case of In-Pile Loop leakage at the core position has been conducted which intended to evaluate the failure of fuel element. By considering design of In-Pile Loop and the highest possibility position of of leakage, the failure of fuel element is emphasized on mechanical aspect. The thermal hydraulic aspect is not taken into account due to the condition that when the leakage occurred the reactor has been in shut down condition. It is determined that the spray attacks the top position of fuel element, and to be calculated the force, of spray that produces 1 cm deflection on the single fuel element. Using that four (4) fuel elements is calculated because in the real condition 4 fuel elements will undergo deflection of 43.8 kg is obtained that producing 1 cm deflection and the force of 1228 kg that causes failure on the bottom of fuel element as shear force is also obtained. Whatever the force, high or low, the damage of fuel element occurred at the bottom part or at the position of grid plate. Therefore there is no damage on the fuel part (uranium meat) and the releasing of radioactive material from fuel plate is not happened

  13. Assessment of structural integrity of Monju steel liner against sodium leakage and combustion. Modeling of thinning process of liner due to corrosion in structural analysis

    International Nuclear Information System (INIS)

    Tsukimori, K.; Kato, T.; Furuhashi, I.; Iwata, K.; Akatsu, M.

    2001-01-01

    The lining structure of LMFBR (Liquid Metal cooled Fast Breeder Reactor) has an important role to prohibit leaking sodium from touching a concrete floor in a sodium leakage incident. JNC (Japan Nuclear Cycle Development Institute) experienced a sodium leakage incident in 1995 in the secondary heat transport system room of the prototype LMFBR MONJU. In this incident, a part of the liner was covered with a certain amount of high temperature leaked sodium and its compounds. Visible but small distortion and thinning of the liner were detected, which were due to heating by sodium fire and chemical corrosion, respectively. To simulate the MONJU incident, JNC conducted a series of sodium leakage tests, in one of which severer corrosion (molten salt type corrosion) than that in the MONJU incident was observed. In order to secure the conservativeness in the integrity assessment of the liner, consideration of a severest corrosion process was demanded. This means that the loss of parts of the structure with time should be considered in the structural analyses. In this study a modeling of thinning process of the liner was developed in order to realize reasonable analysis from the point of view of actual phenomena. The concept of the method is to release the stress of the lost region by using artificial creep and reducing Young's modulus. The necessity of this kind of model and the validity was verified through an application analysis of the liner in the secondary heat transport system room of MONJU. (authors)

  14. Are there risk factors that increase the rate of staple line leakage in patients undergoing primary sleeve gastrectomy for morbid obesity?

    Science.gov (United States)

    Benedix, Frank; Benedix, Diana D; Knoll, Christian; Weiner, Rudolf; Bruns, Christiane; Manger, Thomas; Stroh, Christine

    2014-10-01

    Laparoscopic sleeve gastrectomy (LSG) is currently being performed with increasing frequency worldwide. It offers an excellent weight loss and resolution of comorbidities in the short term with a very low incidence of complications. However, the ever present risk of a staple line leak is still a major concern. Since 2005, data from obese patients that undergo bariatric procedures in Germany are prospectively registered in an online database and analyzed at the Institute of Quality Assurance in Surgical Medicine. For the current analysis, all patients that had undergone primary sleeve gastrectomy for morbid obesity within a 7-year period were considered. Using the GBSR, data from 5.400 LSGs were considered for analysis. Staple line leak rate decreased during the study period from 6.5 to 1.4 %. Male gender, higher BMI, concomitant sleep apnea, conversion to laparotomy, longer operation time, use of both buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate. On multivariate analysis, operation time and year of procedure only had a significant impact on staple line leak rate. The results of the current study demonstrated that there are factors that increase the risk of a leakage which would enable surgeons to define risk groups, to more carefully select patients, and to offer a closer follow-up during the postoperative course with early recognition and adequate treatment. All future efforts should be focused on a further reduction of serious complications to make the LSG a widely accepted and safer procedure.

  15. Study of application of option B at integrated leakage tests on Swedish reactor containments; Utredning om tillaempning av option B vid integrala taethetsprover paa svenska reaktorinneslutningar

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Roger [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Reactor Technology

    2004-12-15

    The task of the reactor containment is to protect the environment from radioactive release from the nuclear power plant. The containment is a passive component and one can therefore not verify its success criteria during normal operation. To verify the integrity of the containment one has to perform integrated leakage tests (type A tests). These tests are performed in accordance with either option A or B in the American regulation Appendix J 10 CFR 50. The choice of option is up to the licensee. Option A does not consider the leakage history of the containment. The test interval is fixed and set to three tests equally distributed over ten years. The test pressure shall be at least half of the design basis accident pressure (DBA-pressure). Option B does take the leakage history into consideration and is therefore performance-based. The test interval can be chosen to a maximum of ten years. The test pressure shall be the DBA-pressure. In Sweden the type A tests are performed in accordance with option A. The purpose of this investigation is to investigate whether option B can be used in Sweden without any significant risk impact. Performance of a type A test with half of the design pressure can result in an undetected leak. If a leak is of such characteristic that it does not show any leakage behaviour until it is exposed to a certain level of pressure where it can open itself, the leak can be missed during a test with too low pressure. On the other hand, option B demands a higher test pressure which contributes to the risk during the performance of the type A test. The advantage of a more correct result from the type A test is considered to be greater than the disadvantage of a high test-pressure. Hence, Type A test shall be performed with the realistic DBA-pressure. The work has included a literature study, telephone interviews, local meetings and analyses of existing PSA results and reports in the subject. An investigation of the On-Line Monitoring (OLM) method is

  16. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  17. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  18. FFTF integrated leak rate computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. The FFTF is the only reactor of this type designed and operated to meet the licensing requirements of the Nuclear Regulatory Commission. Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion of the third FFTF integrated leak rate test 5 days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special network (LAN) of three IBM PC/XT computers, which monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The equipment configuration allowed continuous monitoring of the progress of the test independent of the data acquisition and analysis functions, and it also provided overall improved system reliability by permitting immediate switching to backup computers in the event of equipment failure

  19. Integrated Three-Voltage-Booster DC-DC Converter to Achieve High Voltage Gain with Leakage-Energy Recycling for PV or Fuel-Cell Power Systems

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2015-09-01

    Full Text Available In this paper, an integrated three-voltage-booster DC-DC (direct current to direct current converter is proposed to achieve high voltage gain for renewable-energy generation systems. The proposed converter integrates three voltage-boosters into one power stage, which is composed of an active switch, a coupled-inductor, five diodes, and five capacitors. As compared with conventional high step-up converters, it has a lower component count. In addition, the features of leakage-energy recycling and switching loss reduction can be accomplished for conversion efficiency improvement. While the active switch is turned off, the converter can inherently clamp the voltage across power switch and suppress voltage spikes. Moreover, the reverse-recovery currents of all diodes can be alleviated by leakage inductance. A 200 W prototype operating at 100 kHz switching frequency with 36 V input and 400 V output is implemented to verify the theoretical analysis and to demonstrate the feasibility of the proposed high step-up DC-DC converter.

  20. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  1. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    Energy Technology Data Exchange (ETDEWEB)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H. [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH{sub T} was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle.

  2. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    International Nuclear Information System (INIS)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H.

    2016-01-01

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH_T was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle

  3. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    Science.gov (United States)

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.

  4. 78 FR 62616 - Integrated System Power Rates

    Science.gov (United States)

    2013-10-22

    .... James K. McDonald, Vice President for Corporate Operations/Chief Operating Office, Southwestern Power...) 595-6690, jim.mcdonald@swpa.gov . SUPPLEMENTARY INFORMATION: Rate Order No. SWPA-66, which has been... final approval by the Federal Energy Regulatory Commission. Available: In the marketing area of...

  5. 75 FR 1363 - Integrated System Power Rates

    Science.gov (United States)

    2010-01-11

    ... increased. Those customers taking transformation service will be affected by an increase in that rate... Regulation Purchased. With factors defined as follows: RPA = The Customer's specific monthly dollar amount of... formulas provided in Customers' contracts indicate an overrun on Hydro Peaking Power, and investigation...

  6. Integrated Monetary and Exchange Rate Frameworks

    NARCIS (Netherlands)

    L. Vinhas de Souza

    2002-01-01

    textabstractHere the author empirically estimates if the different monetary and exchange rate frameworks observed in the Accession Countries of Central and Eastern Europe and the Baltics do yield different outcomes in terms of level and variance of a set of nominal and real variables. The author

  7. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  8. 76 FR 50726 - Integrated System Power Rates: Correction

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates: Correction AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of public review and comment; Correction... date listed for the combined Public Information and Comment Forum (Forum) was erroneously listed in the...

  9. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  10. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  11. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  12. 47 CFR 64.1801 - Geographic rate averaging and rate integration.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Geographic rate averaging and rate integration. 64.1801 Section 64.1801 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) MISCELLANEOUS RULES RELATING TO COMMON CARRIERS Geographic Rate Averaging and...

  13. A proposed structural, risk-informed approach to the periodicity of CANDU-6 nuclear containment integrated leak rate testing

    Energy Technology Data Exchange (ETDEWEB)

    Saliba, N. [McGill Univ., Dept. of Civil Engineering and Applied Mechanics, Montreal, Quebec (Canada); Komljenovic, D. [Hydro-Quebec, Gentilly-2 Nuclear Power Plant, Becancour, Quebec (Canada); Chouinard, L. [McGill Univ., Dept. of Civil Engineering and Applied Mechanics, Montreal, Quebec (Canada); Vaillancourt, R.; Chretien, G. [Hydro-Quebec, Gentilly-2 Nuclear Power Plant, Becancour, Quebec (Canada); Gocevski, V. [Hydro-Quebec Equipements, Montreal, Quebec (Canada)

    2010-07-01

    As ultimate lines of defense against leakage of large amounts of radioactive material to the environment in case of major reactor accidents, containments have been monitored through well designed periodic tests to ensure their proper performance. Regulatory organizations have imposed types and frequencies of containment tests based on highly-conservative deterministic approaches, and judgments of knowledgeable experts. Recent developments in the perception and methods of risk evaluation have been applied to rationalize the leakage-rate testing frequencies while maintaining risks within acceptable levels, preserving the integrity of containments, and respecting the defense-in-depth philosophy. The objective of this paper is to introduce a proposed risk-informed decision making framework on the periodicity of nuclear containment ILRTs for CANDU-6 nuclear power plants based on five main decision criteria, namely: 1) the containment structural integrity; 2) inputs from PSA Level-2; 3) the requirements of deterministic safety analyses and defense-in-depth concepts; 4- the obligations under regulatory and standard requirements; and 5) the return of experience from nuclear containments historic performance. The concepts of dormant reliability and structural fragility will guide the assessment of the containment structural integrity, within the general context of a global containment life cycle management program. This study is oriented towards the requirements of CANDU-6 reactors, in general, and Hydro-Quebec's Gentilly-2 nuclear power plant, in particular. The present article is the first part in a series of papers that will comprehensively detail the proposed research. (author)

  14. A proposed structural, risk-informed approach to the periodicity of CANDU-6 nuclear containment integrated leak rate testing

    International Nuclear Information System (INIS)

    Saliba, N.; Komljenovic, D.; Chouinard, L.; Vaillancourt, R.; Chretien, G.; Gocevski, V.

    2010-01-01

    As ultimate lines of defense against leakage of large amounts of radioactive material to the environment in case of major reactor accidents, containments have been monitored through well designed periodic tests to ensure their proper performance. Regulatory organizations have imposed types and frequencies of containment tests based on highly-conservative deterministic approaches, and judgments of knowledgeable experts. Recent developments in the perception and methods of risk evaluation have been applied to rationalize the leakage-rate testing frequencies while maintaining risks within acceptable levels, preserving the integrity of containments, and respecting the defense-in-depth philosophy. The objective of this paper is to introduce a proposed risk-informed decision making framework on the periodicity of nuclear containment ILRTs for CANDU-6 nuclear power plants based on five main decision criteria, namely: 1) the containment structural integrity; 2) inputs from PSA Level-2; 3) the requirements of deterministic safety analyses and defense-in-depth concepts; 4- the obligations under regulatory and standard requirements; and 5) the return of experience from nuclear containments historic performance. The concepts of dormant reliability and structural fragility will guide the assessment of the containment structural integrity, within the general context of a global containment life cycle management program. This study is oriented towards the requirements of CANDU-6 reactors, in general, and Hydro-Quebec's Gentilly-2 nuclear power plant, in particular. The present article is the first part in a series of papers that will comprehensively detail the proposed research. (author)

  15. Three-Axis Attitude Estimation Using Rate-Integrating Gyroscopes

    Science.gov (United States)

    Crassidis, John L.; Markley, F. Landis

    2016-01-01

    Traditionally, attitude estimation has been performed using a combination of external attitude sensors and internal three-axis gyroscopes. There are many studies of three-axis attitude estimation using gyros that read angular rates. Rate-integrating gyros measure integrated rates or angular displacements, but three-axis attitude estimation using these types of gyros has not been as fully investigated. This paper derives a Kalman filtering framework for attitude estimation using attitude sensors coupled with rate- integrating gyroscopes. In order to account for correlations introduced by using these gyros, the state vector must be augmented, compared with filters using traditional gyros that read angular rates. Two filters are derived in this paper. The first uses an augmented state-vector form that estimates attitude, gyro biases, and gyro angular displacements. The second ignores correlations, leading to a filter that estimates attitude and gyro biases only. Simulation comparisons are shown for both filters. The work presented in this paper focuses only on attitude estimation using rate-integrating gyros, but it can easily be extended to other applications such as inertial navigation, which estimates attitude and position.

  16. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  17. Integration of geotechnical and geophysical techniques for the characterization of a small earth-filled canal dyke and the localization of water leakage

    Science.gov (United States)

    Bièvre, Grégory; Lacroix, Pascal; Oxarango, Laurent; Goutaland, David; Monnot, Guy; Fargier, Yannick

    2017-04-01

    This paper investigates the combined use of extensive geotechnical, hydrogeological and geophysical techniques to assess a small earth dyke with a permanent hydraulic head, namely a canal embankment. The experimental site was chosen because of known issues regarding internal erosion and piping phenomena. Two leakages were visually located following the emptying of the canal prior to remediation works. The results showed a good agreement between the geophysical imaging techniques (Electrical Resistivity Tomography, P- and SH-waves Tomography) and the geotechnical data to detect the depth to the bedrock and its lateral variations. It appeared that surface waves might not be fully adapted for dyke investigation because of the particular geometry of the studied dyke, non-respectful of the 1D assumption, and which induced depth and velocity discrepancies retrieved from Rayleigh and Love waves inversion. The use of these classical prospecting techniques however did not allow to directly locate the two leakages within the studied earth dyke. The analysis of ambient vibration time series with a modified beam-forming algorithm allowed to localize the most energetic water flow prior to remediation works. It was not possible to detect the leakage after remediation works, suggesting that they efficiently contributed to significantly reduce the water flow. The second leakage was not detected probably because of a non-turbulent water flow, generating few energetic vibrations.

  18. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  19. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  20. Enabling an Integrated Rate-temporal Learning Scheme on Memristor

    Science.gov (United States)

    He, Wei; Huang, Kejie; Ning, Ning; Ramanathan, Kiruthika; Li, Guoqi; Jiang, Yu; Sze, Jiayin; Shi, Luping; Zhao, Rong; Pei, Jing

    2014-04-01

    Learning scheme is the key to the utilization of spike-based computation and the emulation of neural/synaptic behaviors toward realization of cognition. The biological observations reveal an integrated spike time- and spike rate-dependent plasticity as a function of presynaptic firing frequency. However, this integrated rate-temporal learning scheme has not been realized on any nano devices. In this paper, such scheme is successfully demonstrated on a memristor. Great robustness against the spiking rate fluctuation is achieved by waveform engineering with the aid of good analog properties exhibited by the iron oxide-based memristor. The spike-time-dependence plasticity (STDP) occurs at moderate presynaptic firing frequencies and spike-rate-dependence plasticity (SRDP) dominates other regions. This demonstration provides a novel approach in neural coding implementation, which facilitates the development of bio-inspired computing systems.

  1. Slew Rate Induced Distortion in Switched-Resistor Integrators

    NARCIS (Netherlands)

    Jiraseree-Amornkun, A.; Jiraseree-amornkun, A.; Worapishet, A.; Klumperink, Eric A.M.; Nauta, Bram; Surakampontorn, W.

    2006-01-01

    Abstract—OPAMP-RC integrators built with linear resistors and capacitors can achieve very high linearity. By means of a switched resistor, tuning of the RC time-constant is possible via the duty-cycle of the clock controlling the switched resistor. This paper analyzes the effect of OPAMP slew rate

  2. A new anastomotic leakage model in circular double stapled colorectal anastomosis after low anterior rectum resection in pigs.

    Science.gov (United States)

    Wenger, F A; Szucsik, E; Hoinoiu, B F; Ionac, M; Walz, M K; Schmid, K W; Reis, H

    2013-12-01

    A high incidence of anastomotic leakage (37.5%) is reported after low anterior rectal resection (LAR) and circular double-stapled anastomosis without protective ileostoma. Since the pathomechanism of anastomosis leakage is still unclear, a suitable animal model would be most desirable. The objective was to assess the incidence of clinically apparent and inapparent leakage after LAR in pigs (n = 20). Endpoints were radiological, clinical, macroscopic, and histologic proof of anastomotic leakage on the 9th postoperative day. Integrity of anastomosis was assessed by double-contrast barium examination on 9th postoperative day. Animals were sacrificed and anastomoses were resected for histopathological investigation. In case of earlier clinical apparent anastomotic leakage, radiologic double-contrast barium was performed immediately. LAR with a circular double-stapled anastomosis without protective ileostoma was performed in 20 pigs (m:f = 8:12). Length of resection was 10-20 cm, anastomosis was performed 7 cm ab ano. Five animals (25%) developed clinical apparent anastomotic leakage (no appetite, fever, inactivity, tachypnea, discomfort, pain) between the 6th (n = 1) and 9th (n = 4) postoperative day, proven by double-contrast barium radiographs. Additionally in 1 animal clinical inapparent anastomotic insufficiency was observed radiologically. Total rate of leakage was 30% (n = 6). These results were confirmed by leucocytosis, low potassium levels, in two cases high ALT and AST and local peritonitis in all cases. Including one additional case of clinical inapparent leakage, total rate of anastomotic leakage was 30% (6/20). Thus we managed to establish a new experimental model of anastomotic leakage after low rectal resection comparable to the human situation.

  3. Integrated leak rate testing of the fast flux test facility reactor containment building

    International Nuclear Information System (INIS)

    James, E.B.; Farabee, O.A.; Bliss, R.J.

    1978-01-01

    The initial Integrated Leak Rate Test (ILRT) of the Fast Flux Test Facility containment building was performed from May 27 to June 2, 1978. The test was conducted in air with systems vented and with the containment recirculating coolers in operation. 10 psig and 5 psig tests were run using the absolute pressure test method. The measured leakage rates were .033% Vol/24 hr. and -.0015% Vol/24 hrs. respectively. Subsequent verification tests at both 10 psig and 5 psig proved that the test equipment was operating properly and it was sensitive enough to detect leaks at low pressures. This ILRT was performed at a lower pressure than any previous ILRT on a reactor containment structure in the United States. While the initial design requirements for ice condenser containments called for a part pressure test at 6 psig, the tests were waived due to the apparent statistical problems of data analysis and the repeatability of the data itself at such low pressure. In contrast to this belief, both the 5 and 10 psig ILRT's were performed in a successful manner at FFTF

  4. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  5. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  6. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  7. Salt Lake City Area Integrated Projects: Rate adjustment: Environmental assessment

    International Nuclear Information System (INIS)

    1990-08-01

    The Department of Energy (DOE) has determined that the proposed firm power rate increase for the Salt Lake City Area Integrated Projects (Integrated Projects) power would not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA, 42 USC 4321, et seq.) and, as such, does not require the preparation of an environmental impact statement (EIS). This determination is based on an environmental assessment (EA) prepared by the Western Area Power Administration (Western) dated August 1990 (DOE/EA-0457). The EA identifies and evaluates the potential environmental and socioeconomic effects of the proposed action, and based on the analysis contained therein, DOE concludes that the impacts to the human environment resulting from the implementation of the rate increase would be insignificant

  8. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  9. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  10. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  11. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  12. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  13. Review of nuclear power reactor coolant system leakage events and leak detection requirements

    International Nuclear Information System (INIS)

    Chokshi, N.C.; Srinivasan, M.; Kupperman, D.S.; Krishnaswamy, P.

    2005-01-01

    In response to the vessel head event at the Davis-Besse reactor, the U.S. Nuclear Regulatory Commission (NRC) formed a Lessons Learned Task Force (LLTF). Four action plans were formulated to respond to the recommendations of the LLTF. The action plans involved efforts on barrier integrity, stress corrosion cracking (SCC), operating experience, and inspection and program management. One part of the action plan on barrier integrity was an assessment to identify potential safety benefits from changes in requirements pertaining to leakage in the reactor coolant system (RCS). In this effort, experiments and models were reviewed to identify correlations between crack size, crack-tip-opening displacement (CTOD), and leak rate in the RCS. Sensitivity studies using the Seepage Quantification of Upsets In Reactor Tubes (SQUIRT) code were carried out to correlate crack parameters, such as crack size, with leak rate for various types of crack configurations in RCS components. A database that identifies the leakage source, leakage rate, and resulting actions from RCS leaks discovered in U.S. light water reactors was developed. Humidity monitoring systems for detecting leakage and acoustic emission crack monitoring systems for the detection of crack initiation and growth before a leak occurs were also considered. New approaches to the detection of a leak in the reactor head region by monitoring boric-acid aerosols were also considered. (authors)

  14. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  15. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  16. Social cost of carbon pricing of power sector CO2: accounting for leakage and other social implications from subnational policies

    Science.gov (United States)

    Bistline, John E.; Rose, Steven K.

    2018-01-01

    In environments where climate policy has partial coverage or unequal participation, carbon dioxide (CO2) emissions or economic activity may shift to locations and sectors where emissions are unregulated. This is referred to as leakage. Leakage can offset or augment emissions reductions associated with a policy, which has important environmental and economic implications. Although leakage has been studied at national levels, analysis of leakage for subnational policies is limited. This is despite greater market integration and many existing state and regional environmental regulations in the US. This study explores leakage potential, net emissions changes, and other social implications in the US energy system with regionally differentiated pricing of power sector CO2 emissions. We undertake an economic analysis using EPRI’s US-REGEN model, where power sector CO2 emissions are priced in individual US regions with a range of social cost of carbon (SCC) values. SCC estimates are being considered by policy-makers for valuing potential societal damages from CO2 emissions. In this study, we evaluate the emissions implications within the SCC pricing region, within the power sector outside the SCC region, and outside the power sector (i.e. in the rest of the energy system). Results indicate that CO2 leakage is possible within and outside the electric sector, ranging from negative 70% to over 80% in our scenarios, with primarily positive leakage outcomes. Typically ignored in policy analysis, leakage would affect CO2 reduction benefits. We also observe other potential societal effects within and across regions, such as higher electricity prices, changes in power sector investments, and overall consumption losses. Efforts to reduce leakage, such as constraining power imports into the SCC pricing region likely reduce leakage, but could also result in lower net emissions reductions, as well as larger price increases. Thus, it is important to look beyond leakage and consider a

  17. Application of a diffusion model to measure ion leakage of resurrection plant leaves undergoing desiccation.

    Science.gov (United States)

    Mihailova, Gergana; Kocheva, Konstantina; Goltsev, Vasilij; Kalaji, Hazem M; Georgieva, Katya

    2018-04-01

    Haberlea rhodopensis is a chlorophyll-retaining resurrection plant, which can survive desiccation to air dry state under both low light and sunny environments. Maintaining the integrity of the membrane during dehydration of resurrection plants is extremely important. In the present study, the diffusion model was improved and used for a first time to evaluate the changes in ion leakage through different cellular compartments upon desiccation of H. rhodopensis and to clarify the reasons for significant increase of electrolyte leakage from dry leaves. The applied diffusion approach allowed us to distinguish the performance of plants subjected to dehydration and subsequent rehydration under different light intensities. Well-hydrated (control) shade plants had lower and slower electrolyte leakage compared to control sun plants as revealed by lower values of phase amplitudes, lower rate constants and ion concentration. In well-hydrated and moderately dehydrated plants (50% relative water content, RWC) ion efflux was mainly due to leakage from apoplast. The electrolyte leakage sharply increased in severely desiccated leaves (8% RWC) from both sun and shade plants mainly due to ion efflux from symplast. After 1 day of rehydration the electrolyte leakage was close to control values, indicating fast recovery of plants. We suggest that the enhanced leakage in air-dried leaves should not be considered as damage but rather as a survival mechanism based on a reversible modification in the structure of cell wall, plasma membrane and alterations in vacuolar system of the cells. However, further studies should be conducted to investigate the changes in cell wall/plasma membrane to support this conclusion. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  18. Exchange-rate policy in eastern Europe and EU integration

    Directory of Open Access Journals (Sweden)

    Jozef M. Van Brabant

    2001-09-01

    Full Text Available The paper examines potential conflicts between rapid EU integration of economies in transition (EiTs and their pursuing catch-up by focusing on exchange-rate policies. After justifying the proposed inquiry, official pronouncements on ER policies that EUcandidates are expected to pursue in the run-up to and upon their accession are summarized, and the salient features of recent debates on ER regimes recalled. Inasmuch as EiTs must modernize and reconcile this obligation with EU membership, in spite of the EU's cohesion experience, the paper combines real and nominal convergence issues with institutional changes upon EU accession to draw a novel perspective on the desirable postaccession transition regime for EiTs with a fairly active ER policy and the EU's cohesion strategy. Core components of such a strategy are advocated.

  19. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  20. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  1. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  2. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  3. Dual modal ultra-bright nanodots with aggregation-induced emission and gadolinium-chelation for vascular integrity and leakage detection.

    Science.gov (United States)

    Feng, Guangxue; Li, Jackson Liang Yao; Claser, Carla; Balachander, Akhila; Tan, Yingrou; Goh, Chi Ching; Kwok, Immanuel Weng Han; Rénia, Laurent; Tang, Ben Zhong; Ng, Lai Guan; Liu, Bin

    2018-01-01

    The study of blood brain barrier (BBB) functions is important for neurological disorder research. However, the lack of suitable tools and methods has hampered the progress of this field. Herein, we present a hybrid nanodot strategy, termed AIE-Gd dots, comprising of a fluorogen with aggregation-induced emission (AIE) characteristics as the core to provide bright and stable fluorescence for optical imaging, and gadolinium (Gd) for accurate quantification of vascular leakage via inductively-coupled plasma mass spectrometry (ICP-MS). In this report, we demonstrate that AIE-Gd dots enable direct visualization of brain vascular networks under resting condition, and that they form localized punctate aggregates and accumulate in the brain tissue during experimental cerebral malaria, indicative of hemorrhage and BBB malfunction. With its superior detection sensitivity and multimodality, we hereby propose that AIE-Gd dots can serve as a better alternative to Evans blue for visualization and quantification of changes in brain barrier functions. Copyright © 2017. Published by Elsevier Ltd.

  4. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  5. Control room habitability assessment and in-leakage test for Korean NPP - 15510

    International Nuclear Information System (INIS)

    Song, D.S.; Lee, J.B.; Ha, S.J.; Seong, J.J.

    2015-01-01

    The assessment of control room habitability for Wolsung unit 1 was performed based on GL 2003-01 and Reg. Guide 1.197. The control room habitability program including Control Room Envelope (CRE) in-leakage test procedures, self assessment guidance, CRE boundary control program, CRE maintenance/sealing program was developed for Wolsung unit 1. The integrated CRE test was performed utilizing ASTM E741. There are two operating modes of pressurization and isolation for CRE ventilation test, and four tests were performed using each of the control room HVAC sub-trains. The control room HVAC system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The in-leakage testing was performed in accordance with CRE in-leakage test procedures. In the pressurization mode, measured unfiltered in-leakage rates for train A and train B were 0 CFM and 405 CFM respectively. In the isolation mode, measured unfiltered in-leakage rates for train A and train B were 1,739 CFM and 1,502 CFM, respectively. Maximum concentration of ammonia at the control room HVAC intake is calculated to be 0.027 g/m 3 (39 ppm), and satisfied the toxicity limit of 300 ppm. The test result shows that the measured unfiltered in-leakage is bounded by the regulatory criteria assumed in the design basis radiological analyses. (authors)

  6. An objective comparison of leakage between commonly used earplugs.

    Science.gov (United States)

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P leakage when compared with the cotton ball coated with petroleum jelly (P leakage compared with the customized plug (P leakage than the cotton plug (P leakage rate (f(4,45) = 94 [P water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. An integrated CMOS high data rate transceiver for video applications

    International Nuclear Information System (INIS)

    Liang Yaping; Sun Lingling; Che Dazhi; Liang Cheng

    2012-01-01

    This paper presents a 5 GHz CMOS radio frequency (RF) transceiver built with 0.18 μm RF-CMOS technology by using a proprietary protocol, which combines the new IEEE 802.11n features such as multiple-in multiple-out (MIMO) technology with other wireless technologies to provide high data rate robust real-time high definition television (HDTV) distribution within a home environment. The RF frequencies cover from 4.9 to 5.9 GHz: the industrial, scientific and medical (ISM) band. Each RF channel bandwidth is 20 MHz. The transceiver utilizes a direct up transmitter and low-IF receiver architecture. A dual-quadrature direct up conversion mixer is used that achieves better than 35 dB image rejection without any on chip calibration. The measurement shows a 6 dB typical receiver noise figure and a better than 33 dB transmitter error vector magnitude (EVM) at −3 dBm output power. (semiconductor integrated circuits)

  8. Large Scale System Safety Integration for Human Rated Space Vehicles

    Science.gov (United States)

    Massie, Michael J.

    2005-12-01

    Since the 1960s man has searched for ways to establish a human presence in space. Unfortunately, the development and operation of human spaceflight vehicles carry significant safety risks that are not always well understood. As a result, the countries with human space programs have felt the pain of loss of lives in the attempt to develop human space travel systems. Integrated System Safety is a process developed through years of experience (since before Apollo and Soyuz) as a way to assess risks involved in space travel and prevent such losses. The intent of Integrated System Safety is to take a look at an entire program and put together all the pieces in such a way that the risks can be identified, understood and dispositioned by program management. This process has many inherent challenges and they need to be explored, understood and addressed.In order to prepare truly integrated analysis safety professionals must gain a level of technical understanding of all of the project's pieces and how they interact. Next, they must find a way to present the analysis so the customer can understand the risks and make decisions about managing them. However, every organization in a large-scale project can have different ideas about what is or is not a hazard, what is or is not an appropriate hazard control, and what is or is not adequate hazard control verification. NASA provides some direction on these topics, but interpretations of those instructions can vary widely.Even more challenging is the fact that every individual/organization involved in a project has different levels of risk tolerance. When the discrete hazard controls of the contracts and agreements cannot be met, additional risk must be accepted. However, when one has left the arena of compliance with the known rules, there can be no longer be specific ground rules on which to base a decision as to what is acceptable and what is not. The integrator must find common grounds between all parties to achieve

  9. Sensitivity Analysis on LOCCW of Westinghouse typed Reactors Considering WOG2000 RCP Seal Leakage Model

    International Nuclear Information System (INIS)

    Na, Jang-Hwan; Jeon, Ho-Jun; Hwang, Seok-Won

    2015-01-01

    In this paper, we focus on risk insights of Westinghouse typed reactors. We identified that Reactor Coolant Pump (RCP) seal integrity is the most important contributor to Core Damage Frequency (CDF). As we reflected the latest technical report; WCAP-15603(Rev. 1-A), 'WOG2000 RCP Seal Leakage Model for Westinghouse PWRs' instead of the old version, RCP seal integrity became more important to Westinghouse typed reactors. After Fukushima accidents, Korea Hydro and Nuclear Power (KHNP) decided to develop Low Power and Shutdown (LPSD) Probabilistic Safety Assessment (PSA) models and upgrade full power PSA models of all operating Nuclear Power Plants (NPPs). As for upgrading full power PSA models, we have tried to standardize the methodology of CCF (Common Cause Failure) and HRA (Human Reliability Analysis), which are the most influential factors to risk measures of NPPs. Also, we have reviewed and reflected the latest operating experiences, reliability data sources and technical methods to improve the quality of PSA models. KHNP has operating various types of reactors; Optimized Pressurized Reactor (OPR) 1000, CANDU, Framatome and Westinghouse. So, one of the most challengeable missions is to keep the balance of risk contributors of all types of reactors. This paper presents the method of new RCP seal leakage model and the sensitivity analysis results from applying the detailed method to PSA models of Westinghouse typed reference reactors. To perform the sensitivity analysis on LOCCW of the reference Westinghouse typed reactors, we reviewed WOG2000 RCP seal leakage model and developed the detailed event tree of LOCCW considering all scenarios of RCP seal failures. Also, we performed HRA based on the T/H analysis by using the leakage rates for each scenario. We could recognize that HRA was the sensitive contributor to CDF, and the RCP seal failure scenario of 182gpm leakage rate was estimated as the most important scenario

  10. Sensitivity Analysis on LOCCW of Westinghouse typed Reactors Considering WOG2000 RCP Seal Leakage Model

    Energy Technology Data Exchange (ETDEWEB)

    Na, Jang-Hwan; Jeon, Ho-Jun; Hwang, Seok-Won [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, we focus on risk insights of Westinghouse typed reactors. We identified that Reactor Coolant Pump (RCP) seal integrity is the most important contributor to Core Damage Frequency (CDF). As we reflected the latest technical report; WCAP-15603(Rev. 1-A), 'WOG2000 RCP Seal Leakage Model for Westinghouse PWRs' instead of the old version, RCP seal integrity became more important to Westinghouse typed reactors. After Fukushima accidents, Korea Hydro and Nuclear Power (KHNP) decided to develop Low Power and Shutdown (LPSD) Probabilistic Safety Assessment (PSA) models and upgrade full power PSA models of all operating Nuclear Power Plants (NPPs). As for upgrading full power PSA models, we have tried to standardize the methodology of CCF (Common Cause Failure) and HRA (Human Reliability Analysis), which are the most influential factors to risk measures of NPPs. Also, we have reviewed and reflected the latest operating experiences, reliability data sources and technical methods to improve the quality of PSA models. KHNP has operating various types of reactors; Optimized Pressurized Reactor (OPR) 1000, CANDU, Framatome and Westinghouse. So, one of the most challengeable missions is to keep the balance of risk contributors of all types of reactors. This paper presents the method of new RCP seal leakage model and the sensitivity analysis results from applying the detailed method to PSA models of Westinghouse typed reference reactors. To perform the sensitivity analysis on LOCCW of the reference Westinghouse typed reactors, we reviewed WOG2000 RCP seal leakage model and developed the detailed event tree of LOCCW considering all scenarios of RCP seal failures. Also, we performed HRA based on the T/H analysis by using the leakage rates for each scenario. We could recognize that HRA was the sensitive contributor to CDF, and the RCP seal failure scenario of 182gpm leakage rate was estimated as the most important scenario.

  11. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  12. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  13. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  14. Comparing Natural Gas Leakage Detection Technologies Using an Open-Source "Virtual Gas Field" Simulator.

    Science.gov (United States)

    Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R

    2016-04-19

    We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.

  15. Model for CO2 leakage including multiple geological layers and multiple leaky wells.

    Science.gov (United States)

    Nordbotten, Jan M; Kavetski, Dmitri; Celia, Michael A; Bachu, Stefan

    2009-02-01

    Geological storage of carbon dioxide (CO2) is likely to be an integral component of any realistic plan to reduce anthropogenic greenhouse gas emissions. In conjunction with large-scale deployment of carbon storage as a technology, there is an urgent need for tools which provide reliable and quick assessments of aquifer storage performance. Previously, abandoned wells from over a century of oil and gas exploration and production have been identified as critical potential leakage paths. The practical importance of abandoned wells is emphasized by the correlation of heavy CO2 emitters (typically associated with industrialized areas) to oil and gas producing regions in North America. Herein, we describe a novel framework for predicting the leakage from large numbers of abandoned wells, forming leakage paths connecting multiple subsurface permeable formations. The framework is designed to exploit analytical solutions to various components of the problem and, ultimately, leads to a grid-free approximation to CO2 and brine leakage rates, as well as fluid distributions. We apply our model in a comparison to an established numerical solverforthe underlying governing equations. Thereafter, we demonstrate the capabilities of the model on typical field data taken from the vicinity of Edmonton, Alberta. This data set consists of over 500 wells and 7 permeable formations. Results show the flexibility and utility of the solution methods, and highlight the role that analytical and semianalytical solutions can play in this important problem.

  16. 77 FR 9226 - Physical Systems Integration, LLC; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2012-02-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-1013-000] Physical Systems Integration, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Physical Systems Integration, LLC's application for market-based rate authority, with an accompanying rate...

  17. Statistical Analysis of CO2 Exposed Wells to Predict Long Term Leakage through the Development of an Integrated Neural-Genetic Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Boyun [Univ. of Louisiana, Lafayette, LA (United States); Duguid, Andrew [Battelle, Columbus, OH (United States); Nygaard, Ronar [Missouri Univ. of Science and Technology, Rolla, MO (United States)

    2017-08-05

    The objective of this project is to develop a computerized statistical model with the Integrated Neural-Genetic Algorithm (INGA) for predicting the probability of long-term leak of wells in CO2 sequestration operations. This object has been accomplished by conducting research in three phases: 1) data mining of CO2-explosed wells, 2) INGA computer model development, and 3) evaluation of the predictive performance of the computer model with data from field tests. Data mining was conducted for 510 wells in two CO2 sequestration projects in the Texas Gulf Coast region. They are the Hasting West field and Oyster Bayou field in the Southern Texas. Missing wellbore integrity data were estimated using an analytical and Finite Element Method (FEM) model. The INGA was first tested for performances of convergence and computing efficiency with the obtained data set of high dimension. It was concluded that the INGA can handle the gathered data set with good accuracy and reasonable computing time after a reduction of dimension with a grouping mechanism. A computerized statistical model with the INGA was then developed based on data pre-processing and grouping. Comprehensive training and testing of the model were carried out to ensure that the model is accurate and efficient enough for predicting the probability of long-term leak of wells in CO2 sequestration operations. The Cranfield in the southern Mississippi was select as the test site. Observation wells CFU31F2 and CFU31F3 were used for pressure-testing, formation-logging, and cement-sampling. Tools run in the wells include Isolation Scanner, Slim Cement Mapping Tool (SCMT), Cased Hole Formation Dynamics Tester (CHDT), and Mechanical Sidewall Coring Tool (MSCT). Analyses of the obtained data indicate no leak of CO2 cross the cap zone while it is evident that the well cement sheath was invaded by the CO2 from the storage zone. This observation is consistent

  18. Experiments about the integrity of BWR relief pipes in postulated radiolysis gas combustion. Scenario No.2. Minor steam leakages without any lowering of the water level

    International Nuclear Information System (INIS)

    Friedrich, A.; Grune, J.; Sempert, K.; Stern, G.; Kuznetsov, M.; Redlinger, R.; Breitung, W.; Franke, T.

    2008-01-01

    The experiments described in this article were performed to study this comprehensive radiolysis gas scenario: - The relief pipe is filled completely with radiolysis gas (2H 2 +O 2 ). - After opening of the S and R valve, the radiolysis gas is compressed adiabatically by the incoming steam without mixing. - Roughly at the point of peak pressure in the relief pipe (20 bar) the radiolysis gas ignites. This dynamic scenario was studied in steady-state model experiments with a test pipe which corresponds to the relief pipes installed in KKP-1 in terms of materials, dimensions, and manufacturing control. The initial conditions and boundary conditions of the experiments were conservative. In the course of the tests, the maximum dynamic strain and the residual plastic deformation of the test pipe were measured via the transient detonation load. The maximum dynamic strain measured was 0.75%, the maximum residual plastic strain reached 0.15%. The pipe suffered no other deformation above and beyond this slight plastic strain. The radiolysis gas detonation was simulated very well numerically. Using the calculated pressure loads in a structural dynamics model also showed good agreement with the measured maximum dynamic pipe strains. In this way, the experimental findings were confirmed theoretically. The experiments and the calculations showed that postulated radiolysis gas reactions during pressure relief cannot jeopardize the integrity of the relief pipe. (orig.)

  19. Application of an Integrated Assessment Model to the Kevin Dome site, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Minh [Univ. of Wyoming, Laramie, WY (United States); Zhang, Ye [Univ. of Wyoming, Laramie, WY (United States); Carey, James William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-30

    The objectives of the Integrated Assessment Model is to enable the Fault Swarm algorithm in the National Risk Assessment Partnership, ensure faults are working in the NRAP-IAM tool, calculate hypothetical fault leakage in NRAP-IAM, and compare leakage rates to Eclipse simulations.

  20. Integrating User Reviews and Ratings for Enhanced Personalized Searching

    Science.gov (United States)

    Hu, Shuyue; Cai, Yi; Leung, Ho-fung; Huang, Dongping; Yang, Yang

    2017-01-01

    With the development of e-commerce, websites such as Amazon and eBay have become very popular. Users post reviews of products and rate the helpfulness of reviews on these websites. Reviews written by a user and reviews rated by a user reflect the user's interests and disinterest. Thus, they are very useful for user profiling. In this study, the…

  1. Leakage potential through mechanical penetrations in a severe accident environment

    International Nuclear Information System (INIS)

    Koenig, L.N.

    1986-01-01

    This paper reviews the findings of an ongoing program, Integrity of Containment Penetrations Under Severe Accident Loads. The program is concerned with the leakage modes as well as the magnitude of leakage through mechanical penetrations in a containment building subject to a severe accident. Seal and gasket tests are used to evaluate the effect of radiation aging, thermal aging, seal geometry, and seal squeeze on seals and gaskets subjected to a hypothesized severe accident. The effects on leakage of the structural response of equipment hatches, personnel airlocks, and drywell heads subjected to severe accident pressures are studied by experiments and analyses. The data gathered during this program will be used to develop methodologies for predicting leakage

  2. Fractal modeling of fluidic leakage through metal sealing surfaces

    Science.gov (United States)

    Zhang, Qiang; Chen, Xiaoqian; Huang, Yiyong; Chen, Yong

    2018-04-01

    This paper investigates the fluidic leak rate through metal sealing surfaces by developing fractal models for the contact process and leakage process. An improved model is established to describe the seal-contact interface of two metal rough surface. The contact model divides the deformed regions by classifying the asperities of different characteristic lengths into the elastic, elastic-plastic and plastic regimes. Using the improved contact model, the leakage channel under the contact surface is mathematically modeled based on the fractal theory. The leakage model obtains the leak rate using the fluid transport theory in porous media, considering that the pores-forming percolation channels can be treated as a combination of filled tortuous capillaries. The effects of fractal structure, surface material and gasket size on the contact process and leakage process are analyzed through numerical simulations for sealed ring gaskets.

  3. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... completion of the operation the patients were randomized in two groups with and without a transanal stent. RESULTS: A clinically significant leakage was diagnosed in 25 patients (13%). No significant difference was found 17 of 98 patients with a stent and 8 of 96 without (P = 0.09), or in 9 of 44 ileostomy...... patients with a stent and in 3 of 45 without (P = 0.07). Several leaks over a short time led to an interim analysis after inclusion of 194 of 448 planned patients. The analysis showed no significant protective effect of the stent, and more leakages in the stent group, although not statistically significant...

  4. Integrated rate expression for the production of glucose equivalent ...

    Indian Academy of Sciences (India)

    WINTEC

    green plants is discussed. The C4 plants are chosen and in these plants, the rate of photosynthesis does not .... overall CO2 assimilation process and glucose pro-. Figure 1. ..... Thus these plants show an optimal growth of an enzyme activity ...

  5. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  6. Anomaly detection using magnetic flux leakage technology

    Energy Technology Data Exchange (ETDEWEB)

    Rempel, Raymond G. [BJ Pipeline Inspection Services, Alberta (Canada)

    2005-07-01

    There are many aspects to properly assessing the integrity of a pipeline. In-line-Inspection (ILI) tools, in particular those that employ the advanced use of Magnetic Flux Leakage (MFL) technology, provide a valuable means of achieving required up-to-date knowledge of a pipeline. More prevalent use of High Resolution MFL In-Line-Inspection tools is growing the knowledge base that leads to more reliable and accurate identification of anomalies in a pipeline, thus, minimizing the need for expensive verification excavations. Accurate assessment of pipeline anomalies can improve the decision making process within an Integrity Management Program and excavation programs can then focus on required repairs instead of calibration or exploratory digs. Utilizing the information from an MFL ILI inspection is not only cost effective but, as well, can also prove to be an extremely valuable building block of a Pipeline Integrity Management Program. (author)

  7. An experimental approach to determining subsurface leakage from a surface impoundment using a radioisotope tracer

    International Nuclear Information System (INIS)

    Ashwood, T.L.; Story, J.D.; Larsen, I.L.; Schultz, F.J.

    1987-01-01

    Bromine-82, a 35.3-h half-life radionuclide, was used as a tracer to determine the paths and rates of leakage from an unlined, 1,000,000-gal (3,785,000 L), surface impoundment at the Oak Ridge National Laboratory. Since the impoundment is underlain and surrounded by storm sewer and sanitary sewer lines (most of them predating the impoundment), known and suspected leak sites in storm drain catch basins and sanitary sewer manholes were sampled periodically and analyzed for 82 Br. A series of four ground water monitoring wells - three downgradient and one upgradient from the impoundment - were also sampled for 82 Br. Although the catch basin and manhole samples picked up 82 Br in leakage from the impoundment less than 5 h after application of the tracer, the monitoring well samples did not contain detectable levels of the radionuclide. It was concluded that the monitoring wells were sampling groundwater moving through the formation, whereas the storm drains and manholes were sampling water leading rapidly through secondary porosity and along preferred pathways. The decline in tracer concentration as a function of time was used to determine the residence time of water in the pond and hence the flow rate through the pond. This flow rate, when compared with the known outflow rate, indicated that the leakage flow was small. Hence, the main value of the test was to identify rapid leakage pathways. The experiment demonstrates the need for sampling subsurface drain systems as part of an integrated monitoring system for leak detection. The effectiveness of 82 Br as a tracer for rapid leaks was also shown

  8. Carprofen for perioperative analgesia causes early anastomotic leakage in the rat ileum.

    Science.gov (United States)

    van der Vijver, Rozemarijn J; van Laarhoven, Cees J H M; Lomme, Roger M L M; Hendriks, Thijs

    2012-12-27

    There is increasing evidence that perioperative use of NSAIDs may compromise the integrity of intestinal anastomoses. This study aims to characterize the negative effects of carprofen on early anastomotic healing in the rat ileum. In 159 male Wistar rats an anastomosis was constructed in the ileum. In experiment 1 eighty-four rats were divided over control and experimental groups, which received daily buprenorphine or carprofen, respectively, as an analgesic and were killed on day 1, 2 or 3 after surgery. In experiment 2 three groups of 15 rats received carprofen either immediately after surgery or with a delay of 1 or 2 days. Animals were killed after 3 days of carprofen administration. In experiment 3 three groups of 10 rats received different doses (full, half or quarter) of carprofen from surgery. In significant contrast to buprenorphine, which never did so, carprofen induced frequent signs of anastomotic leakage, which were already present at day 1. If first administration was delayed for 48 hours, the leakage rate was significantly reduced (from 80 to 20%; p = 0.0028). Throughout the study, the anastomotic bursting pressure was lowest in animals who displayed signs of anastomotic leakage. Loss of anastomotic integrity did not coincide with reduced levels of hydroxyproline or increased activity of matrix metalloproteinases. Carprofen interferes with wound healing in the rat ileum at a very early stage. Although the mechanisms responsible remain to be fully elucidated, one should be aware of the potential of NSAIDs to interfere with the early phase of wound repair.

  9. Effects of coffee management on deforestation rates and forest integrity.

    Science.gov (United States)

    Hylander, Kristoffer; Nemomissa, Sileshi; Delrue, Josefien; Enkosa, Woldeyohannes

    2013-10-01

    Knowledge about how forest margins are utilized can be crucial for a general understanding of changes in forest cover, forest structure, and biodiversity across landscapes. We studied forest-agriculture transitions in southwestern Ethiopia and hypothesized that the presence of coffee (Coffea arabica)decreases deforestation rates because of coffee's importance to local economies and its widespread occurrence in forests and forest margins. Using satellite images and elevation data, we compared changes in forest cover over 37 years (1973-2010) across elevations in 2 forest-agriculture mosaic landscapes (1100 km(2) around Bonga and 3000 km(2) in Goma-Gera). In the field in the Bonga area, we determined coffee cover and forest structure in 40 forest margins that differed in time since deforestation. Both the absolute and relative deforestation rates were lower at coffee-growing elevations compared with at higher elevations (-10/20% vs. -40/50% comparing relative rates at 1800 m asl and 2300-2500 m asl, respectively). Within the coffee-growing elevation, the proportion of sites with high coffee cover (>20%) was significantly higher in stable margins (42% of sites that had been in the same location for the entire period) than in recently changed margins (0% of sites where expansion of annual crops had changed the margin). Disturbance level and forest structure did not differ between sites with 30% or 3% coffee. However, a growing body of literature on gradients of coffee management in Ethiopia reports coffee's negative effects on abundances of forest-specialist species. Even if the presence of coffee slows down the conversion of forest to annual-crop agriculture, there is a risk that an intensification of coffee management will still threaten forest biodiversity, including the genetic diversity of wild coffee. Conservation policy for Ethiopian forests thus needs to develop strategies that acknowledge that forests without coffee production may have higher deforestation

  10. IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE

    International Nuclear Information System (INIS)

    Andrews, J.W.

    2002-01-01

    The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases

  11. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  12. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  13. Geomechanical effects on CO2 leakage through fault zones during large-scale underground injection

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Antonio P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cappa, Frédéric [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of Nice Sophia-Antipolis, Nice (France). Cote d' Azur Observatory. GeoAzur

    2013-12-01

    The importance of geomechanics—including the potential for faults to reactivate during large-scale geologic carbon sequestration operations—has recently become more widely recognized. However, notwithstanding the potential for triggering notable (felt) seismic events, the potential for buoyancy-driven CO2 to reach potable groundwater and the ground surface is actually more important from public safety and storage-efficiency perspectives. In this context, this paper extends the previous studies on the geomechanical modeling of fault responses during underground carbon dioxide injection, focusing on the short-term integrity of the sealing caprock, and hence on the potential for leakage of either brine or CO2 to reach the shallow groundwater aquifers during active injection. We consider stress/strain-dependent permeability and study the leakage through the fault zone as its permeability changes during a reactivation, also causing seismicity. We analyze several scenarios related to the volume of CO2 injected (and hence as a function of the overpressure), involving both minor and major faults, and analyze the profile risks of leakage for different stress/strain-permeability coupling functions. We conclude that whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. Moreover, our analysis shows that induced seismicity associated with fault reactivation may not necessarily open up a new flow path for leakage. Results show a poor correlation between magnitude and amount of fluid leakage, meaning that a single event is generally not enough to substantially change the permeability along the entire fault length. Finally, and consequently, even if some changes in permeability occur, this does not mean that the CO2 will migrate up along the entire fault, breaking through the caprock to enter the overlying aquifer.

  14. Leakage of pressurized gases through unlined concrete containment structures

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.

    1983-01-01

    Eight reinforced concrete specimens were fabricated and subjected to tensile membrane forces and air pressure to study the air leakage characteristics in cracked reinforced concrete members. A mathematical expression for the rate of pressurized air flowing through an idealized crack is presented. The mathematical expression is refined by using the experimental data to describe the air flow rate through any given crack pattern. Graphical charts are also presented for the calculation of the air leakage rate through concrete cracks. The concept of equivalent crack width for a given crack pattern is introduced. The mathematical expression and graphical charts are modified to include this equivalent crack width concept. The proposed technique is applicable for the prediction of the leakage from concrete containment structures or any similar structures due to high internal pressure sufficient to initiate cracking. (orig.)

  15. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.; van Noort, Reinier; Spiers, Christopher J.

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  16. Reanastomosis with Stapler in Duodenojejunal Junction Anastomosis Leakage: A Case Report

    Directory of Open Access Journals (Sweden)

    Ahmet Seker

    2013-04-01

    Full Text Available After anastomosis leakages, treatment of patient gets more difficult and mortality rates increase. At lower level gastrointestinal anastomosis leakages, because of always there is an ostomy alternative, digestion problems are seen lesser. But at upper level gastrointestinal system anastomosis leakages, when it is taken account of nutrient condition of patient, requirement of making anastomos increases. So moratlity rates increase. At this article we aimed to present a different technique that we administered on management of a patient who had duodenojejunal junction anastomosis leakage.

  17. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  18. [Bile leakage after liver resection: A retrospective cohort study].

    Science.gov (United States)

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (pBile leakage significantly prolonged hospitalization time (pbile leakage the perioperative mortality was 23 times higher (pBile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve

  19. Potential gonadal dose from leakage radiation?

    International Nuclear Information System (INIS)

    Nicholson, R.A.

    1995-01-01

    The author draws attention to the potential dangers of leakage radiation from mobile image intensifier units, and points out that during interventional urological procedures, radiation from below the urologist's knees may irradiate male gonads without being intercepted by protective aprons. Results are presented for a Shimatzu WHA mobile II, phantom doses being measured with an ionization chamber. Dose rates measured in the male gonad position were compared with rates at waist level behind a 0.35 mm lead equivalent shielding and dose rates at collar level outside the lead apron. Results are also presented of a study on the effect on gonad dose of a) adding 0.7 mm lead shielding to the tube housing and b) adding 0.7 mm lead and removing the spacer cone to reduce scatter. Results show that it is possible for gonad doses to be comparable with those assumed for the eyes, rather than the body. (Author)

  20. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  1. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  2. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  3. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  4. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  5. CO2 leakage alters biogeochemical and ecological functions of submarine sands

    Science.gov (United States)

    Molari, Massimiliano; Guilini, Katja; Lott, Christian; Weber, Miriam; de Beer, Dirk; Meyer, Stefanie; Ramette, Alban; Wegener, Gunter; Wenzhöfer, Frank; Martin, Daniel; Cibic, Tamara; De Vittor, Cinzia; Vanreusel, Ann; Boetius, Antje

    2018-01-01

    Subseabed CO2 storage is considered a future climate change mitigation technology. We investigated the ecological consequences of CO2 leakage for a marine benthic ecosystem. For the first time with a multidisciplinary integrated study, we tested hypotheses derived from a meta-analysis of previous experimental and in situ high-CO2 impact studies. For this, we compared ecological functions of naturally CO2-vented seafloor off the Mediterranean island Panarea (Tyrrhenian Sea, Italy) to those of nonvented sands, with a focus on biogeochemical processes and microbial and faunal community composition. High CO2 fluxes (up to 4 to 7 mol CO2 m−2 hour−1) dissolved all sedimentary carbonate, and comigration of silicate and iron led to local increases of microphytobenthos productivity (+450%) and standing stocks (+300%). Despite the higher food availability, faunal biomass (−80%) and trophic diversity were substantially lower compared to those at the reference site. Bacterial communities were also structurally and functionally affected, most notably in the composition of heterotrophs and microbial sulfate reduction rates (−90%). The observed ecological effects of CO2 leakage on submarine sands were reproduced with medium-term transplant experiments. This study assesses indicators of environmental impact by CO2 leakage and finds that community compositions and important ecological functions are permanently altered under high CO2. PMID:29441359

  6. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  7. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  8. Up to 20 Gbit/s bit-rate transparent integrated interferometric wavelength converter

    DEFF Research Database (Denmark)

    Jørgensen, Carsten; Danielsen, Søren Lykke; Hansen, Peter Bukhave

    1996-01-01

    We present a compact and optimised multiquantum-well based, integrated all-active Michelson interferometer for 26 Gbit/s optical wavelength conversion. Bit-rate transparent operation is demonstrated with a conversion penalty well below 0.5 dB at bit-rates ranging from 622 Mbit/s to 20 Gbit/s....

  9. Studies of axial-leakage simulations for homogeneous and heterogeneous EBR-II core configurations

    International Nuclear Information System (INIS)

    Grimm, K.N.; Meneghetti, D.

    1985-08-01

    When calculations of flux are done in less than three dimensions, leakage-absorption cross sections are normally used to model leakages (flows) in the dimensions for which the flux is not calculated. Since the neutron flux is axially dependent, the leakages, and hence the leakage-absorption cross sections, are also axially dependent. Therefore, to obtain axial flux profiles (or reaction rates) for individual subassemblies, an XY-geometry calculation delineating each subassembly has to be done at several axial heights with space- and energy-dependent leakage-absorption cross sections that are appropriate for each height. This report discusses homogeneous and heterogeneous XY-geometry calculations at various axial locations and using several differing assumptions for the calculation of the leakage-absorption cross section. The positive (outward) leakage-absorption cross sections are modeled as actual leakage absorptions, but the negative (inward) leakage-absorption cross sections are modeled as either negative leakage absorptions (+-B 2 method) or positive downscatter cross sections [the Σ/sub s/(1 → g) method]. 3 refs., 52 figs., 10 tabs

  10. Social integration prospectively predicts changes in heart rate variability among individuals undergoing migration stress.

    Science.gov (United States)

    Gouin, Jean-Philippe; Zhou, Biru; Fitzpatrick, Stephanie

    2015-04-01

    Poor social integration increases risk for poor health. The psychobiological pathways underlying this effect are not well-understood. This study utilized a migration stress model to prospectively investigate the impact of social integration on change in high-frequency heart rate variability (HF-HRV), a marker of autonomic functioning. Sixty new international students were recruited shortly after their arrival in the host country and assessed 2 and 5 months later. At each assessment period, participants provided information on social integration and loneliness and had their resting HF-HRV evaluated. There was an overall decrease in HF-HRV over time. The magnitude of the within-person and between-person effects of social integration on HRV increased over time, such that greater social integration was associated with higher HF-HRV at later follow-ups. These results suggest that altered autonomic functioning might represent a key pathway linking social integration to health outcomes.

  11. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  12. THREATS AND BENEFITS OF EXCHANGE RATE REGIMES FOR UKRAINE IN TERMS OF EUROPEAN INTEGRATION

    OpenAIRE

    Svitlana Glushchenko; Svitlana Tkalenko

    2016-01-01

    The purpose of the paper is to determine threats and benefits of exchange rate regimes in terms of the integration of Ukraine into the European community. Emphasizing features of the manifestation of currency exchange rate in Ukrainian practice is a precondition for choosing the optimal exchange rate regime for Ukraine, which, in its turn, will provide an opportunity to reduce inflation and implement effective tools of monetary and fiscal policies to promote further economic growth and compet...

  13. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    Science.gov (United States)

    White, Curt [Pittsburgh, PA; Wells, Arthur [Bridgeville, PA; Diehl, J Rodney [Pittsburgh, PA; Strazisar, Brian [Venetia, PA

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  14. Estimation of leakage power and delay in CMOS circuits using parametric variation

    Directory of Open Access Journals (Sweden)

    Preeti Verma

    2016-09-01

    Full Text Available With the advent of deep-submicron technologies, leakage power dissipation is a major concern for scaling down portable devices that have burst-mode type integrated circuits. In this paper leakage reduction technique HTLCT (High Threshold Leakage Control Transistor is discussed. Using high threshold transistors at the place of low threshold leakage control transistors, result in more leakage power reduction as compared to LCT (leakage control transistor technique but at the scarifies of area and delay. Further, analysis of effect of parametric variation on leakage current and propagation delay in CMOS circuits is performed. It is found that the leakage power dissipation increases with increasing temperature, supply voltage and aspect ratio. However, opposite pattern is noticed for the propagation delay. Leakage power dissipation for LCT NAND gate increases up to 14.32%, 6.43% and 36.21% and delay decreases by 22.5%, 42% and 9% for variation of temperature, supply voltage and aspect ratio. Maximum peak of equivalent output noise is obtained as 127.531 nV/Sqrt(Hz at 400 mHz.

  15. Is ASEAN Ready for Banking Integration? Evidence from Interest Rate Convergence

    Directory of Open Access Journals (Sweden)

    Fazelina Sahul Hamid

    2016-07-01

    Full Text Available Convergence in prices or returns of assets with similar characteristics indicates that the financial market is integrated with regional markets. This paper is the first that test of the movements of interest rates in ASEAN banking sector for the period 1990 - 2012. The empirical analysis is based on a yearly panel of commercial bank interest rate data from 5 ASEAN countries, namely, Indonesia, Malaysia, Philippines, Singapore and Thailand. We assessed the degree and speed of interest rate convergence using beta and sigma convergence method. The findings show that the difference and the dispersion in the interbank rates have reduced since the Asian financial crisis and this trend has become stronger after the Global financial crisis. The findings of this study confirm that interest rates in the ASEAN banking sector are converging. This provides evidence that the ASEAN banking sector is ready for financial integration.

  16. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  17. Research on leakage detection of nuclear power station primary loop

    International Nuclear Information System (INIS)

    Cao Shengquan; Yang Jicai; Li Jianjun; Dong Zhijuan; Ren Juyan; Zhang Pinyuan

    1993-01-01

    The sensor of leak-detection system is a special humidity-sensitive element. In this system, the collection and treatment of detected data, and the leakage alarm are controlled by a simple board computer. The three parameters A, B and C are set up in this system, and the alarm will give out when signal surpasses values of B and C at the same time. The effects of environment humidity and temperature on collection of detected data are considered, and the leakage alarm is reliable. When the leakage rate of water at 320 degree C and 12.2 MPa is 0.3 g/min, the alarm signal will sent out within 5 s

  18. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  19. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  20. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  1. Real exchange-rates, co-integration and purchasing power parity - Irish experience in the EMS

    OpenAIRE

    Thom, R

    1989-01-01

    Dickey-Fuller and Co-Integration techniques are used to test the hypothesis that co-movements in Irish nominal exchange rates and relative prices are consistent with the implications of Purchasing Power Parity. The data reject PPP between Ireland and the US. Results from Irish/UK and Irish/German data are less decisive against the possibility that linear combinations of the nominal exchange rate and corresponding relative prices are stationary series.

  2. Integrated leak rate test of the FFTF [Fast Flux Test Facility] containment vessel

    International Nuclear Information System (INIS)

    Grygiel, M.L.; Davis, R.H.; Polzin, D.L.; Yule, W.D.

    1987-04-01

    The third integrated leak rate test (ILRT) performed at the Fast Flux Test Facility (FFTF) demonstrated that effective leak rate measurements could be obtained at a pressure of 2 psig. In addition, innovative data reduction methods demonstrated the ability to accurately account for diurnal variations in containment pressure and temperature. Further development of methods used in this test indicate significant savings in the time and effort required to perform an ILRT on Liquid Metal Reactor Systems with consequent reduction in test costs

  3. What determines crime rates? An empirical test of integrated economic and sociological theories of criminal behavior

    NARCIS (Netherlands)

    Engelen, Peter Jan; Lander, Michel W.; van Essen, Marc

    Research on crime has by no means reached a definitive conclusion on which factors are related to crime rates. We contribute to the crime literature by providing an integrated empirical model of economic and sociological theories of criminal behavior and by using a very comprehensive set of

  4. Integration of aerial imaging and variable-rate technology for site-specific aerial herbicide application

    Science.gov (United States)

    As remote sensing and variable rate technology are becoming more available for aerial applicators, practical methodologies on effective integration of these technologies are needed for site-specific aerial applications of crop production and protection materials. The objectives of this study were to...

  5. A modified Gaussian integration method for thermal reaction rate calculation in U- and Pu-isotopes

    International Nuclear Information System (INIS)

    Bosevski, T.; Fredin, B.

    1966-01-01

    An advanced multi-group cell calculations a lot of data information is very often necessary, and hence the data administration will be elaborate, and the spectrum calculation will be time consuming. We think it is possible to reduce the necessary data information by using an effective reaction rate integration method well suited for U- and Pu-absorptions (author)

  6. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  7. The Effect of Internal Leakages on Thermal Performance in NPPs

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Kim, Doo Won; Jang, Seok Bo

    2007-01-01

    Since the Balance Of Plant (BOP, limited to a turbine cycle in this study) does not contain radioactive material, regulatory authorities did not need to have concerns on it. As the interests on safety and performance is getting more serious and extensive, controlling the level of safety and performance of a BOP have just begun or is about to begin. The performance standards or ageing management programs of the major equipment in a BOP is being developed. The regulatory requirements for tests and/or maintenance are being actively built up. There is also a probabilistic approach quantifying performance of a BOP. The study on quantifying the rate of unanticipated shutdowns caused by careless maintenance and/or tests conducted in a BOP is going on. In this study, the modeling of the entire BOP and the methodologies of thermal performance analysis should be one of the must-have items as well. This study was achieved to ensure fundamental skills related to 1) the detailed steady-state modeling of a BOP and 2) thermal performance analysis under various conditions. Particularly, the paper will focus on the effect of internal leakages inside the valves and FeedWater Heaters (FWHs). The internal leakage is regarded as the flow movement through the isolated path but remaining inside the system boundary of a BOP. For instance, the leakage from one side of a valve seat to the other side, or the leakage through the cracked tubes or tube-sheets in a heat exchanger correspond to internal leakages. We made a BOP model of OPR1000 and investigated thermal performance under the internal leakage in Turbine Bypass Condenser Dump Valves (TBCDV) and FWHs

  8. Carprofen for perioperative analgesia causes early anastomotic leakage in the rat ileum

    Directory of Open Access Journals (Sweden)

    van der Vijver Rozemarijn J

    2012-12-01

    Full Text Available Abstract Background There is increasing evidence that perioperative use of NSAIDs may compromise the integrity of intestinal anastomoses. This study aims to characterize the negative effects of carprofen on early anastomotic healing in the rat ileum. Results In 159 male Wistar rats an anastomosis was constructed in the ileum. In experiment 1 eighty-four rats were divided over control and experimental groups, which received daily buprenorphine or carprofen, respectively, as an analgesic and were killed on day 1, 2 or 3 after surgery. In experiment 2 three groups of 15 rats received carprofen either immediately after surgery or with a delay of 1 or 2 days. Animals were killed after 3 days of carprofen administration. In experiment 3 three groups of 10 rats received different doses (full, half or quarter of carprofen from surgery. In significant contrast to buprenorphine, which never did so, carprofen induced frequent signs of anastomotic leakage, which were already present at day 1. If first administration was delayed for 48 hours, the leakage rate was significantly reduced (from 80 to 20%; p = 0.0028. Throughout the study, the anastomotic bursting pressure was lowest in animals who displayed signs of anastomotic leakage. Loss of anastomotic integrity did not coincide with reduced levels of hydroxyproline or increased activity of matrix metalloproteinases. Conclusions Carprofen interferes with wound healing in the rat ileum at a very early stage. Although the mechanisms responsible remain to be fully elucidated, one should be aware of the potential of NSAIDs to interfere with the early phase of wound repair.

  9. Leakage losses from a hydraulic fracture and fracture propagation

    International Nuclear Information System (INIS)

    Johnson, R.E.; Gustafson, C.W.

    1988-01-01

    The fluid mechanics of viscous fluid injection into a fracture embedded in a permeable rock formation is studied. Coupling between flow in the fracture and flow in the rock is retained. The analysis is based on a perturbation scheme that assumes the depth of penetration of the fluid into the rock is small compared to the characteristic length w 3 0 /k, where w 0 is the characteristic crack width and k is the permeability. This restriction, however, is shown to be minor. The spatial dependence of the leakage rate per unit length from the fracture is found to be linear, decreasing from the well bore to the fracture tip where it vanishes. The magnitude of the leakage rate per unit length is found to decay in time as t -1 /sup // 3 if the injection rate at the well bore is constant, and as t -1 /sup // 2 if the well bore pressure is held constant. The results cast considerable doubt on the validity of Carter's well-known leakage formula (Drilling Prod. Prac. API 1957, 261) derived from a one-dimensional theory. Using the simple fracture propagation model made popular by Carter, the present work also predicts that the fracture grows at a rate proportional to t 1 /sup // 3 for a fixed well bore injection rate and a rate proportional to t 1 /sup // 4 for a fixed well bore pressure

  10. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  11. Insulator photocurrents: Application to dose rate hardening of CMOS/SOI integrated circuits

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.; Coiec, Y.M.; Flament, O.; Tinel, F.

    1998-01-01

    Irradiation of insulators with a pulse of high energy x-rays can induce photocurrents in the interconnections of integrated circuits. The authors present, here, a new method to measure and analyze this effect together with a simple model. They also demonstrate that these insulator photocurrents have to be taken into account to obtain high levels of dose-rate hardness with CMOS on SOI integrated circuits, especially flip-flops or memory blocks of ASICs. They show that it explains some of the upsets observed in a SRAM embedded in an ASIC

  12. The Study of an Integrated Rating System for Supplier Quality Performance in the Semiconductor Industry

    Science.gov (United States)

    Lee, Yu-Cheng; Yen, Tieh-Min; Tsai, Chih-Hung

    This study provides an integrated model of Supplier Quality Performance Assesment (SQPA) activity for the semiconductor industry through introducing the ISO 9001 management framework, Importance-Performance Analysis (IPA) Supplier Quality Performance Assesment and Taguchi`s Signal-to-Noise Ratio (S/N) techniques. This integrated model provides a SQPA methodology to create value for all members under mutual cooperation and trust in the supply chain. This method helps organizations build a complete SQPA framework, linking organizational objectives and SQPA activities to optimize rating techniques to promote supplier quality improvement. The techniques used in SQPA activities are easily understood. A case involving a design house is illustrated to show our model.

  13. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  14. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  15. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  16. Very high frame rate volumetric integration of depth images on mobile devices.

    Science.gov (United States)

    Kähler, Olaf; Adrian Prisacariu, Victor; Yuheng Ren, Carl; Sun, Xin; Torr, Philip; Murray, David

    2015-11-01

    Volumetric methods provide efficient, flexible and simple ways of integrating multiple depth images into a full 3D model. They provide dense and photorealistic 3D reconstructions, and parallelised implementations on GPUs achieve real-time performance on modern graphics hardware. To run such methods on mobile devices, providing users with freedom of movement and instantaneous reconstruction feedback, remains challenging however. In this paper we present a range of modifications to existing volumetric integration methods based on voxel block hashing, considerably improving their performance and making them applicable to tablet computer applications. We present (i) optimisations for the basic data structure, and its allocation and integration; (ii) a highly optimised raycasting pipeline; and (iii) extensions to the camera tracker to incorporate IMU data. In total, our system thus achieves frame rates up 47 Hz on a Nvidia Shield Tablet and 910 Hz on a Nvidia GTX Titan XGPU, or even beyond 1.1 kHz without visualisation.

  17. Influence of leakage flow on the behaviour of gas behind a blockage in LMFBR subassembly geometry

    International Nuclear Information System (INIS)

    Fukuzawa, Y.

    1980-07-01

    Observations were made of the behaviour of gas behind a uniform porous 21% corner blockage within a pin-bundle of LMFBR subassembly geometry. The main parameter of the experiment was the leakage flow rate through the blockage. The behaviour of gas is significantly influenced by the leakage flow rate. The measured size and residence time of a gas cavity formed behind the blockage are shown and the mechanisms of the gas cavity dispersion by the leakage flow discussed by using a simple model of the liquid flow distribution behind the blockage. (orig.) [de

  18. Nonlinearity and fractional integration in the US dollar/euro exchange rate

    Directory of Open Access Journals (Sweden)

    Kiran Burcu

    2012-01-01

    Full Text Available This paper examines the nonlinear behavior and the fractional integration property of the US dollar/euro exchange rate over the period from January 1999 to August 2010 by extending the procedure of Peter M. Robinson (1994 to the case of nonlinearity. First, using the approach developed by Mehmet Caner and Bruce E. Hansen (2001, we investigate the possible presence of nonlinearity in the series through the estimation of a two-regime threshold autoregressive model. After finding nonlinearity, we also allow for disturbances to be fractionally integrated based on the different versions of Robinson (1994 tests. The findings show that the US dollar/euro exchange rate follows a stationary process with a weak evidence for long memory.

  19. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  20. Pipeline leakage recognition based on the projection singular value features and support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wei; Zhang, Laibin; Mingda, Wang; Jinqiu, Hu [College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, (China)

    2010-07-01

    The negative wave pressure method is one of the processes used to detect leaks on oil pipelines. The development of new leakage recognition processes is difficult because it is practically impossible to collect leakage pressure samples. The method of leakage feature extraction and the selection of the recognition model are also important in pipeline leakage detection. This study investigated a new feature extraction approach Singular Value Projection (SVP). It projects the singular value to a standard basis. A new pipeline recognition model based on the multi-class Support Vector Machines was also developed. It was found that SVP is a clear and concise recognition feature of the negative pressure wave. Field experiments proved that the model provided a high recognition accuracy rate. This approach to pipeline leakage detection based on the SVP and SVM has a high application value.

  1. On the muon-nucleus integrals entering the neutrinoless μ- → e- conversion rates

    International Nuclear Information System (INIS)

    Kosmas, T S; Lagaris, I E

    2002-01-01

    The muon-nucleus integrals which determine the nuclear-structure dependence of the branching ratio R μe , i.e. the rate of the flavour-changing muon-electron conversion divided by the total rate of the ordinary muon capture, are extensively studied. Precise muon wavefunctions are employed which are obtained by solving the Schroedinger and Dirac equations. To this aim a method based on modern neural network techniques is developed which gives the radial muon wavefunctions as a linear combination of sigmoid functions

  2. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  3. Decreased plasma levels of the endothelial protective sphingosine-1-phosphate are associated with dengue-induced plasma leakage

    NARCIS (Netherlands)

    Michels, M.; Japtok, L.; Alisjahbana, B.; Wisaksana, R.; Sumardi, U.; Puspita, M.; Kleuser, B.; Mast, Q. de; Ven, A.J.A.M. van der

    2015-01-01

    BACKGROUND: A transient endothelial hyperpermeability is a hallmark of severe dengue infections. Sphingosine-1-phosphate (S1P) maintains vascular integrity and protects against plasma leakage. We related plasma S1P levels to dengue-induced plasma leakage and studied mechanisms that may underlie the

  4. Preventive testing and leakage detection in pipe-lines of steam condensers and generators of a PWR type reactor

    International Nuclear Information System (INIS)

    Canalini, A.; Carvalho, N.C. de

    1985-01-01

    The non-destructive methods: Spum, Helium and Hydrostatic used in leakage detection in condenser pipelines for PWR type reactors are presented. The time, costs, sensitivity, resources necessary and personnel development factors are considered to choose adequated method, in function of nuclear power plant conditions. The leakage tests are applied in pressurized systems or vacuum. Eddy Current testing is used in condensers and steam generators aiming to avoid leakage in these equipments. The spume testing for leakage detection in condenser pipelines - which operation - and hydrostatic testing for leakage detection through reaming with shutdown - were most efficients. The Helium testing applied in pressurized systems or submitted to vacuum systems presented satisfactory results. The Eddy Current testing in condenser and steam generator pipelines reached desired objective, reducing leakage in the first and preserving the integrity in the second. (M.C.K.) [pt

  5. Laccase-13 Regulates Seed Setting Rate by Affecting Hydrogen Peroxide Dynamics and Mitochondrial Integrity in Rice

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2017-07-01

    Full Text Available Seed setting rate is one of the most important components of rice grain yield. To date, only several genes regulating setting rate have been identified in plant. In this study, we showed that laccase-13 (OsLAC13, a member of laccase family genes which are known for their roles in modulating phenylpropanoid pathway and secondary lignification in cell wall, exerts a regulatory function in rice seed setting rate. OsLAC13 expressed in anthers and promotes hydrogen peroxide production both in vitro and in the filaments and anther connectives. Knock-out of OsLAC13 showed significantly increased seed setting rate, while overexpression of this gene exhibited induced mitochondrial damage and suppressed sugar transportation in anthers, which in turn affected seed setting rate. OsLAC13 also induced H2O2 production and mitochondrial damage in the root tip cells which caused the lethal phenotype. We also showed that high abundant of OsmiR397, the suppressor of OsLAC13 mRNA, increased the seed setting rate of rice plants, and restrains H2O2 accumulation in roots during oxidative stress. Our results suggested a novel regulatory role of OsLAC13 gene in regulating seed setting rate by affecting H2O2 dynamics and mitochondrial integrity in rice.

  6. Practical implementation of a higher order transverse leakage approximation

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomašević

    2011-01-01

    Transverse integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming in this approach, be it via the Analytic Nodal Method or Nodal Expansion Method, is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In this work an improved, consistent quadratic leakage approximation is formulated, which derives from the class of higher order nodal methods developed some years ago. In this new approach, only information relevant to describing the transverse leak- age terms in the zero-order nodal equations are obtained from the higher order formalism. The method yields accuracy comparable to full higher order methods, but does not suffer from the same computational burden which these methods typically incur. (author)

  7. Integrating spatial and temporal oxygen data to improve the quantification of in situ petroleum biodegradation rates.

    Science.gov (United States)

    Davis, Gregory B; Laslett, Dean; Patterson, Bradley M; Johnston, Colin D

    2013-03-15

    Accurate estimation of biodegradation rates during remediation of petroleum impacted soil and groundwater is critical to avoid excessive costs and to ensure remedial effectiveness. Oxygen depth profiles or oxygen consumption over time are often used separately to estimate the magnitude and timeframe for biodegradation of petroleum hydrocarbons in soil and subsurface environments. Each method has limitations. Here we integrate spatial and temporal oxygen concentration data from a field experiment to develop better estimates and more reliably quantify biodegradation rates. During a nine-month bioremediation trial, 84 sets of respiration rate data (where aeration was halted and oxygen consumption was measured over time) were collected from in situ oxygen sensors at multiple locations and depths across a diesel non-aqueous phase liquid (NAPL) contaminated subsurface. Additionally, detailed vertical soil moisture (air-filled porosity) and NAPL content profiles were determined. The spatial and temporal oxygen concentration (respiration) data were modeled assuming one-dimensional diffusion of oxygen through the soil profile which was open to the atmosphere. Point and vertically averaged biodegradation rates were determined, and compared to modeled data from a previous field trial. Point estimates of biodegradation rates assuming no diffusion ranged up to 58 mg kg(-1) day(-1) while rates accounting for diffusion ranged up to 87 mg kg(-1) day(-1). Typically, accounting for diffusion increased point biodegradation rate estimates by 15-75% and vertically averaged rates by 60-80% depending on the averaging method adopted. Importantly, ignoring diffusion led to overestimation of biodegradation rates where the location of measurement was outside the zone of NAPL contamination. Over or underestimation of biodegradation rate estimates leads to cost implications for successful remediation of petroleum impacted sites. Crown Copyright © 2013. Published by Elsevier Ltd. All rights

  8. Integrated Strategic Planning of Global Production Networks and Financial Hedging under Uncertain Demands and Exchange Rates

    Directory of Open Access Journals (Sweden)

    Achim Koberstein

    2013-11-01

    Full Text Available In this paper, we present a multi-stage stochastic programming model that integrates financial hedging decisions into the planning of strategic production networks under uncertain exchange rates and product demands. This model considers the expenses of production plants and the revenues of markets in different currency areas. Financial portfolio planning decisions for two types of financial instruments, forward contracts and options, are represented explicitly by multi-period decision variables and a multi-stage scenario tree. Using an illustrative example, we analyze the impact of exchange-rate and demand volatility, the level of investment expenses and interest rate spreads on capacity location and dimensioning decisions. In particular, we show that, in the illustrative example, the exchange-rate uncertainty cannot be completely eliminated by financial hedging in the presence of demand uncertainty. In this situation, we find that the integrated model can result in better strategic planning decisions for a risk-averse decision maker compared to traditional modeling approaches.

  9. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  10. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  11. [Impact of sperm DNA and acrosome integrity and acrosome reaction rate on outcomes of rescue intracytoplasmic sperm injection].

    Science.gov (United States)

    He, Yongzhi; Li, Dawen; Cheng, Junping; Huo, Zhongchao; Huang, Hongyi; Xiao, Xin

    2016-01-01

    Objective To explore the effects of sperm DNA integrity rate, acrosome integrity rate and acrosome reaction rate on the outcomes of rescue intracytoplasmic sperm injection (ICSI). This retrospective analysis was conducted among 97 infertile couples receiving rescue ICSI due to failure of in vitro fertilization procedures in our Reproductive Medicine Center. Of these 97 women, 41 had clinical pregnancy and 56 did not, and the effects of sperm DNA integrity rate (estimated by DNA fragmentation index, DFI), acrosome integrity rate and acrosome reaction rate on rescue ICSI outcomes were analyzed. No significant difference was found in paternal age, testosterone value, testicular volume, FSH, female patient' age or the number of eggs retrieved between the two groups (P>0.05), but the infertility years was significantly shorter in the pregnancy group than in the non-pregnancy group (Prate and cleavage rate were similar between the two groups (P>0.05), but the good embryo rate was significantly higher in the pregnancy group (Preaction rate did not differ significantly between the two groups (P>0.05), but the acrosome integrity rate was significantly higher in the pregnancy group (Prate, acrosome integrity or acrosome reaction rate were not correlated with the fertilization rate, cleavage rate or good embryo rate (P>0.05). The pregnancy rate, twin and single fetus rates were 42.3%, 10.3% and 32.0% in this cohort after recue ICSI, respectively. Rescue ICSI is an effective treatment after failed in vitro fertilization procedure, and sperm acrosome integrity rate is associated with the outcome of rescue ICSI.

  12. AKTIS Nr. 12: To better understand radioactive aerosol deposit in order to better measure it; Radio-induced lesions: a new step towards healing; Modelling the collapse of an immersed grain column; To better model soot deposit; Towards the prediction of the leakage rate of containment enclosures

    International Nuclear Information System (INIS)

    Benderitter, Marc; Perales, Frederic; Monerie, Yann; Maro, Denis; Boyer, Patrick; Lemaitre, Pascal; Porcheron, Emmanuel; Depuydt, Guillaume; Masson, Olivier; Gensdarmes, Francois

    2013-04-01

    This publication presents the main results of researches undertaken by the IRSN in the field of radiation protection, nuclear safety and security. The topics herein addressed are: radio-induced lesions as a new step towards healing (case of injection mesenchymal stem cells for the treatment of induced severe colorectal lesions), the modelling of the collapse of an immersed grain column (to study the nuclear fuel behaviour in an accidental situation through a modelling of fluid-grain interactions), a better understanding of radioactive aerosol deposit (to study particle or aerosol deposits after radioactive releases in the atmosphere in case of accident), a better modelling of soot deposits (in case of fire), the prediction of leakage rates of containment enclosures (ageing phenomena of installations, systems and equipment, with the case of cracks due to material ageing and resulting in confinement losses which could thus be quantified)

  13. The potential impact of integrated malaria transmission control on entomologic inoculation rate in highly endemic areas.

    Science.gov (United States)

    Killeen, G F; McKenzie, F E; Foy, B D; Schieffelin, C; Billingsley, P F; Beier, J C

    2000-05-01

    We have used a relatively simple but accurate model for predicting the impact of integrated transmission control on the malaria entomologic inoculation rate (EIR) at four endemic sites from across sub-Saharan Africa and the southwest Pacific. The simulated campaign incorporated modestly effective vaccine coverage, bed net use, and larval control. The results indicate that such campaigns would reduce EIRs at all four sites by 30- to 50-fold. Even without the vaccine, 15- to 25-fold reductions of EIR were predicted, implying that integrated control with a few modestly effective tools can meaningfully reduce malaria transmission in a range of endemic settings. The model accurately predicts the effects of bed nets and indoor spraying and demonstrates that they are the most effective tools available for reducing EIR. However, the impact of domestic adult vector control is amplified by measures for reducing the rate of emergence of vectors or the level of infectiousness of the human reservoir. We conclude that available tools, including currently neglected methods for larval control, can reduce malaria transmission intensity enough to alleviate mortality. Integrated control programs should be implemented to the fullest extent possible, even in areas of intense transmission, using simple models as decision-making tools. However, we also conclude that to eliminate malaria in many areas of intense transmission is beyond the scope of methods which developing nations can currently afford. New, cost-effective, practical tools are needed if malaria is ever to be eliminated from highly endemic areas.

  14. Efficient Simulation of Compressible, Viscous Fluids using Multi-rate Time Integration

    Science.gov (United States)

    Mikida, Cory; Kloeckner, Andreas; Bodony, Daniel

    2017-11-01

    In the numerical simulation of problems of compressible, viscous fluids with single-rate time integrators, the global timestep used is limited to that of the finest mesh point or fastest physical process. This talk discusses the application of multi-rate Adams-Bashforth (MRAB) integrators to an overset mesh framework to solve compressible viscous fluid problems of varying scale with improved efficiency, with emphasis on the strategy of timescale separation and the application of the resulting numerical method to two sample problems: subsonic viscous flow over a cylinder and a viscous jet in crossflow. The results presented indicate the numerical efficacy of MRAB integrators, outline a number of outstanding code challenges, demonstrate the expected reduction in time enabled by MRAB, and emphasize the need for proper load balancing through spatial decomposition in order for parallel runs to achieve the predicted time-saving benefit. This material is based in part upon work supported by the Department of Energy, National Nuclear Security Administration, under Award Number DE-NA0002374.

  15. An integrated low-voltage rated HTS DC power system with multifunctions to suit smart grids

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian Xun, E-mail: jxjin@uestc.edu.cn [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Center of Applied Superconductivity and Electrical Engineering, School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731 (China); Chen, Xiao Yuan [School of Engineering, Sichuan Normal University, Chengdu 610101 (China); Qu, Ronghai; Fang, Hai Yang [School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Xin, Ying [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2015-03-15

    Highlights: • A novel LVDC HTS power transmission network is presented. • An integrated power system is achieved by using HTS DC cable and SMES. • DC superconducting cable is verified to achieve self-acting fault current limitation. • SMES is verified to achieve fast-response buffering effect under a power fluctuation. • SMES is verified to achieve favorable load voltage protection effect under a fault. - Abstract: A low-voltage rated DC power transmission network integrated with superconducting cables (SCs) and superconducting magnetic energy storage (SMES) devices has been studied with analytic results presented. In addition to the properties of loss-less and high current transportation capacity, the effectively integrated system is formed with a self-acting fault current limitation feature of the SC and a buffering effect of the SMES to power fluctuations. The results obtained show that the integrated system can achieve high-quality power transmission under common power fluctuation conditions with an advanced self-protection feature under short circuit conditions, which is identified to suit especially the smart grid applications.

  16. Structure factors for tunneling ionization rates of molecules: General Hartree-Fock-based integral representation

    Science.gov (United States)

    Madsen, Lars Bojer; Jensen, Frank; Dnestryan, Andrey I.; Tolstikhin, Oleg I.

    2017-07-01

    In the leading-order approximation of the weak-field asymptotic theory (WFAT), the dependence of the tunneling ionization rate of a molecule in an electric field on its orientation with respect to the field is determined by the structure factor of the ionizing molecular orbital. The WFAT yields an expression for the structure factor in terms of a local property of the orbital in the asymptotic region. However, in general quantum chemistry approaches molecular orbitals are expanded in a Gaussian basis which does not reproduce their asymptotic behavior correctly. This hinders the application of the WFAT to polyatomic molecules, which are attracting increasing interest in strong-field physics. Recently, an integral-equation approach to the WFAT for tunneling ionization of one electron from an arbitrary potential has been developed. The structure factor is expressed in an integral form as a matrix element involving the ionizing orbital. The integral is not sensitive to the asymptotic behavior of the orbital, which resolves the difficulty mentioned above. Here, we extend the integral representation for the structure factor to many-electron systems treated within the Hartree-Fock method and show how it can be implemented on the basis of standard quantum chemistry software packages. We validate the methodology by considering noble-gas atoms and the CO molecule, for which accurate structure factors exist in the literature. We also present benchmark results for CO2 and for NH3 in the pyramidal and planar geometries.

  17. Numerical studies of CO2 and brine leakage into a shallow aquifer through an open wellbore

    Science.gov (United States)

    Wang, Jingrui; Hu, Litang; Pan, Lehua; Zhang, Keni

    2018-03-01

    Industrial-scale geological storage of CO2 in saline aquifers may cause CO2 and brine leakage from abandoned wells into shallow fresh aquifers. This leakage problem involves the flow dynamics in both the wellbore and the storage reservoir. T2Well/ECO2N, a coupled wellbore-reservoir flow simulator, was used to analyze CO2 and brine leakage under different conditions with a hypothetical simulation model in water-CO2-brine systems. Parametric studies on CO2 and brine leakage, including the salinity, excess pore pressure (EPP) and initially dissolved CO2 mass fraction, are conducted to understand the mechanism of CO2 migration. The results show that brine leakage rates increase proportionally with EPP and inversely with the salinity when EPP varies from 0.5 to 1.5 MPa; however, there is no CO2 leakage into the shallow freshwater aquifer if EPP is less than 0.5 MPa. The dissolved CO2 mass fraction shows an important influence on the CO2 plume, as part of the dissolved CO2 becomes a free phase. Scenario simulation shows that the gas lifting effect will significantly increase the brine leakage rate into the shallow freshwater aquifer under the scenario of 3.89% dissolved CO2 mass fraction. The equivalent porous media (EPM) approach used to model the wellbore flow has been evaluated and results show that the EPM approach could either under- or over-estimate brine leakage rates under most scenarios. The discrepancies become more significant if a free CO2 phase evolves. Therefore, a model that can correctly describe the complex flow dynamics in the wellbore is necessary for investigating the leakage problems.

  18. Pad use and patient reported bother from urinary leakage after radical prostatectomy.

    Science.gov (United States)

    Wallerstedt, Anna; Carlsson, Stefan; Nilsson, Andreas E; Johansson, Eva; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2012-01-01

    To better understand clinically significant definitions of urinary incontinence we investigated the relationship between urinary leakage and patient reported bother from urinary leakage. A consecutive series of 1,411 men who underwent radical prostatectomy at Karolinska University Hospital, Stockholm, Sweden, from 2002 to 2006 were invited to complete a study specific questionnaire with questions on pad status, urinary leakage and bother from urinary leakage. Questionnaires were received from 1,179 men with a followup of greater than 1 year (median 2.2). Results showed that even a small amount of urinary leakage resulted in a high risk of urinary bother. Of 775 survivors 46 (6%) reporting 0 pads indicated moderate or much bother compared to 38 of 123 (31%) who reported using a security pad. When comparing the 2 groups, the risk of bother from urinary leakage was more than 5 times higher in the safety pad vs the 0 pad group (RR 5.2, 95% CI 3.5-7.7). As the number of pads increased, we noted a higher bother risk. Cross-tabulation of pad use and urinary leakage revealed wide variation in pad requirements despite the same answer to urinary leakage questions. If the definition of continence is based on pad use, for example safety pads, a certain number of men who report moderate or much bother from urinary leakage will be defined as continent. Our results also show that for each stated rate of urinary leakage men prove to have a major variation in the pad requirement. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. The TIGRESS Integrated Plunger ancillary systems for electromagnetic transition rate studies at TRIUMF

    International Nuclear Information System (INIS)

    Voss, P.; Henderson, R.; Andreoiu, C.; Ashley, R.; Austin, R.A.E.; Ball, G.C.; Bender, P.C.; Bey, A.; Cheeseman, A.; Chester, A.; Cross, D.S.; Drake, T.E.; Garnsworthy, A.B.; Hackman, G.; Holland, R.; Ketelhut, S.; Kowalski, P.; Krücken, R.; Laffoley, A.T.; Leach, K.G.

    2014-01-01

    The TIGRESS Integrated Plunger device is a new experimental tool for nuclear structure investigations via gamma-ray spectroscopy with post-accelerated beams from the ISAC-II facility at TRIUMF. Several ancillary detection systems integral to the device's capabilities for charged-particle tagging and light-ion identification following a variety of nuclear reaction mechanisms have been constructed and characterized. In particular, a silicon PIN diode wall, an annular silicon segmented detector, and a CsI(Tl) scintillator wall have together enabled particle-gamma correlations for reaction channel selectivity and precision kinematic reconstruction in recent measurements. We highlight the construction, characteristics, and implementation of the device's ancillary detectors as they enable a rich set of electromagnetic transition rate measurements via Doppler-shift lifetime techniques and low-energy Coulomb excitation

  20. Adaptive Command Filtered Integrated Guidance and Control for Hypersonic Vehicle with Magnitude, Rate and Bandwidth Constraints

    Directory of Open Access Journals (Sweden)

    Wang Liang

    2018-01-01

    Full Text Available This paper proposes a novel integrated guidance and control (IGC method for hypersonic vehicle in terminal phase. Firstly, the system model is developed with a second order actuator dynamics. Then the back-stepping controller is designed hierarchically with command filters, where the first order command filters are implemented to construct the virtual control input with ideal states predicted by an adaptive estimator, and the nonlinear command filter is designed to produce magnitude, rate and bandwidth limited control surface deflection finally tracked by a terminal sliding mode controller with finite convergence time. Through a series of 6-DOF numerical simulations, it’s indicated that the proposed method successfully cancels out the large aerodynamics coefficient uncertainties and disturbances in hypersonic flight under limited control surface deflection. The contribution of this paper lies in the application and determination of nonlinear integrated design of guidance and control system for hypersonic vehicle.

  1. A method for determining leakage of 133Xe gas from septum-sealed glass vials

    International Nuclear Information System (INIS)

    McAllister, J.R.; Borak, T.B.; Pellicciarini, D.W.

    2000-01-01

    The authors have developed a method for determining the leakage of 133 Xe gas from septum-sealed glass vials that are supplied for medical examinations. Twenty vials each originally containing 370 MPq of 133 Xe and 20 vials each originally containing 740 MBq 133 Xe were measured daily for 26 d. Retention of 133 Xe within the vial was modeled as a first order process with a constant rate coefficient, λ T . The value of λ T was estimated for each vial using a regression analysis. The leakage rate, λ L , was then determined assuming that λ L = λ L + λ r where λ r represents the physical decay of 133 Xe. Monte Carlo simulations were performed using uncertainties in the estimates of each vial to obtain the mean and tails of the distribution for the average leakage rate, bar λ L . the average leakage rate for the complete sample of vials was 0.00007 d -1 with an upper, one-sided, 95% confidence limit of 0.0011 d -1 . Uncertainties in the published values of λ r for 133 Xe made a significant contribution to the uncertainties of the leakage rate for this sample of vials. The methods described can be applied to other situations where leakage of radioactive materials may be of concern

  2. An Integrated Assessment of Geochemical and Community Structure Determinants of Metal Reduction Rates in Subsurface Sediments

    International Nuclear Information System (INIS)

    Pfiffner, Susan M.; Brandt, Craig C.; Kostka, Joel E.; Palumbo, Anthony V.

    2005-01-01

    Our current research represents a joint effort between Oak Ridge National Laboratory (ORNL), Florida State University (FSU), and the University of Tennessee. ORNL will serve as the lead institution with Dr. A.V. Palumbo responsible for project coordination, integration, and deliverables. This project was initiated in November, 2004, in the Integrative Studies Element of the NABIR program. The overall goal of our project is to provide an improved understanding of the relationships between microbial community structure, geochemistry, and metal reduction rates. The research seeks to address the following questions: Is the metabolic diversity of the in situ microbial community sufficiently large and redundant that bioimmobilization of uranium will occur regardless of the type of electron donor added to the system? Are their donor specific effects that lead to enrichment of specific community members that then impose limits on the functional capabilities of the system? Will addition of humics change rates of uranium reduction without changing community structure? Can resource-ratio theory be used to understand changes in uranium reduction rates and community structure with respect to changing C:P ratios?

  3. Current leakage relaxation and charge trapping in ultra-porous low-k materials

    International Nuclear Information System (INIS)

    Borja, Juan; Plawsky, Joel L.; Gill, William N.; Lu, T.-M.; Bakhru, Hassaram

    2014-01-01

    Time dependent dielectric failure has become a pivotal aspect of interconnect design as industry pursues integration of sub-22 nm process-technology nodes. Literature has provided key information about the role played by individual species such as electrons, holes, ions, and neutral impurity atoms. However, no mechanism has been shown to describe how such species interact and influence failure. Current leakage relaxation in low-k dielectrics was studied using bipolar field experiments to gain insight into how charge carrier flow becomes impeded by defects within the dielectric matrix. Leakage current decay was correlated to injection and trapping of electrons. We show that current relaxation upon inversion of the applied field can be described by the stretched exponential function. The kinetics of charge trapping events are consistent with a time-dependent reaction rate constant, k=k 0 ⋅(t+1) β−1 , where 0 < β < 1. Such dynamics have previously been observed in studies of charge trapping reactions in amorphous solids by W. H. Hamill and K. Funabashi, Phys. Rev. B 16, 5523–5527 (1977). We explain the relaxation process in charge trapping events by introducing a nonlinear charge trapping model. This model provides a description on the manner in which the transport of mobile defects affects the long-tail current relaxation processes in low-k films

  4. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  5. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  6. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.

  7. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  8. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  9. ERROR REDUCTION IN DUCT LEAKAGE TESTING THROUGH DATA CROSS-CHECKS

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS, J.W.

    1998-12-31

    One way to reduce uncertainty in scientific measurement is to devise a protocol in which more quantities are measured than are absolutely required, so that the result is over constrained. This report develops a method for so combining data from two different tests for air leakage in residential duct systems. An algorithm, which depends on the uncertainty estimates for the measured quantities, optimizes the use of the excess data. In many cases it can significantly reduce the error bar on at least one of the two measured duct leakage rates (supply or return), and it provides a rational method of reconciling any conflicting results from the two leakage tests.

  10. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  11. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  12. Extending the performance of single-degree-of-freedom rate integrating gyros in strapdown applications

    Science.gov (United States)

    Baker, G. N.

    This paper examines the constraints upon a typical manufacturer of gyros and strapdown systems. It describes that while being responsive to exchange and keeping abreast of 'state of the art' technology, there are many reasons why the manufacturer must satisfy the market using existing technology and production equipment. The Single-Degree-of-Freedom Rate Integrating Gyro is a well established product, yet is capable of achieving far higher performances than originally envisaged due to modelling and characterization within digital strapdown systems. The parameters involved are discussed, and a description given of the calibration process undertaken on a strapdown system being manufactured in a production environment in batch quantities.

  13. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  14. THREATS AND BENEFITS OF EXCHANGE RATE REGIMES FOR UKRAINE IN TERMS OF EUROPEAN INTEGRATION

    Directory of Open Access Journals (Sweden)

    Svitlana Glushchenko

    2016-11-01

    Full Text Available The purpose of the paper is to determine threats and benefits of exchange rate regimes in terms of the integration of Ukraine into the European community. Emphasizing features of the manifestation of currency exchange rate in Ukrainian practice is a precondition for choosing the optimal exchange rate regime for Ukraine, which, in its turn, will provide an opportunity to reduce inflation and implement effective tools of monetary and fiscal policies to promote further economic growth and competitiveness of the country. The uses of free-floating exchange rate and «currency board» regimes have either positive effects for Ukraine or certain threats. Methodology. This research is based on a synthesis of data on the uses of exchange rate regimes in Ukraine as an independent. It is considered angular regimes, which are by far the most suitable for Ukraine in terms of the European vector of its development. Peculiarities of using these regimes are revealed and their major threats to the domestic economy are pointed out. This article analyzes the dynamics of the trade balance of payments of Ukraine, the dynamics of the commodity structure of Ukraine`s exports and imports and the external debt of Ukraine. Results. Taking into account the experience of countries, which were in crisis situations, they show the necessity of the uses of freefloating exchange rate regime and possibilities of «currency board» regime, despite threats that they may have. World experience testifies the implementation of structural reforms, effective monetary policy, fiscal policy and discipline of the government. Thorough preparation of Ukraine’s transition to the «currency board» regime can justify itself in conditions of crisis and provide impetus to Ukrainian economy benefits. The paper defines conditions under which the success of a new model of exchange rate policy will be achieved. Practical implications. The study accents attention on the specifics of the uses of the

  15. Study of 1-min rain rate integration statistic in South Korea

    Science.gov (United States)

    Shrestha, Sujan; Choi, Dong-You

    2017-03-01

    The design of millimeter wave communication links and the study of propagation impairments at higher frequencies due to a hydrometeor, particularly rain, require the knowledge of 1-min. rainfall rate data. Signal attenuation in space communication results are due to absorption and scattering of radio wave energy. Radio wave attenuation due to rain depends on the relevance of a 1-min. integration time for the rain rate. However, in practice, securing these data over a wide range of areas is difficult. Long term precipitation data are readily available. However, there is a need for a 1-min. rainfall rate in the rain attenuation prediction models for a better estimation of the attenuation. In this paper, we classify and survey the prominent 1-min. rain rate models. Regression analysis was performed for the study of cumulative rainfall data measured experimentally for a decade in nine different regions in South Korea, with 93 different locations, using the experimental 1-min. rainfall accumulation. To visualize the 1-min. rainfall rate applicable for the whole region for 0.01% of the time, we have considered the variation in the rain rate for 40 stations across South Korea. The Kriging interpolation method was used for spatial interpolation of the rain rate values for 0.01% of the time into a regular grid to obtain a highly consistent and predictable rainfall variation. The rain rate exceeded the 1-min. interval that was measured through the rain gauge compared to the rainfall data estimated using the International Telecommunication Union Radio Communication Sector model (ITU-R P.837-6) along with the empirical methods as Segal, Burgueno et al., Chebil and Rahman, logarithmic, exponential and global coefficients, second and third order polynomial fits, and Model 1 for Icheon regions under the regional and average coefficient set. The ITU-R P. 837-6 exhibits a lower relative error percentage of 3.32% and 12.59% in the 5- and 10-min. to 1-min. conversion, whereas the

  16. Integrated High-Rate Transition Radiation Detector and Tracking Chamber for the LHC

    CERN Multimedia

    2002-01-01

    % RD-6 \\\\ \\\\Over the past five years, RD-6 has developed a transition radiation detector and charged particle tracker for high rate operation at LHC. The detector elements are based on C-fibre reinforced kapton straw tubes of 4~mm diameter filled with a Xenon gas mixture. Detailed measurements with and without magnetic field have been performed in test beams, and in particular have demonstrated the possibility of operating straw tubes at very high rate (up to 20~MHz) with accurate drift-time measurement accuracy. A full-scale engineering prototype containing 10~000 straws is presently under assembly and will be accurately measured with a powerful X-ray tube. Integrated front-end electronics with fast readout have been designed and successfully operated in test beam. \\\\ \\\\Finally extensive simulations performed for ATLAS have shown that such a detector will provide powerful pattern recognition, accurate momentum measurements, efficient level-2 triggering and excellent electron identification, even at the highe...

  17. Fail-safe first wall for preclusion of little leakage

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    Leakages although excluded by design measures would occur most probably in highly stressed areas, weldments and locations without possibility to classify the state by in-service inspection. In a water-cooled first wall, allowable leak rate of water is generally very small, and therefore, locating of the leak portion under highly activated environment will be very difficult and be time-consuming. The double-wall concept is promising for the ITER first wall, because it can be made fail-safe by the application of the leak-before-break and the multiple load path concepts, and because it has a potential capability to solve the little leak problem. When the fail safe strength is well defined, subcritical crack growth in the damaged wall can be permitted. This will enable to detect stable leakage of coolant without deteriorating plasma operation. The paper deals with the little leak problem and presents method for evaluating small leak rate of a liquid coolant from crack-like defects. The fail-safe first wall with the double-wall concept is also proposed for preclusion of little leakage and its fail-safety is discussed. (author)

  18. Leakage flow simulation in a specific pump model

    International Nuclear Information System (INIS)

    Dupont, P; Bayeul-Lainé, A C; Dazin, A; Bois, G; Roussette, O; Si, Q

    2014-01-01

    This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 8.06 code (RANS frozen and unsteady calculations). Comparisons between numerical and experimental results are presented and discussed for three flow rates. The performances of the diffuser obtained by numerical simulation results are compared to the performances obtained by three-hole probe indications. The comparisons show few influence of fluid leakage on global performances but a real improvement concerning the efficiency of the impeller, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up

  19. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  20. Allocation of emission permits with leakage through capital markets

    International Nuclear Information System (INIS)

    Maestad, Ottar

    2007-01-01

    This paper analyses how tradable emission permits should be allocated to firms when capital is internationally mobile. When international environmental problems are attempted solved through uncoordinated policies between countries, it might be desirable for the home country to issue free emission permits in proportion to the use of capital in order to prevent leakage through international capital movements. The desirability of free emission permits will however be reduced if capital also can be employed in a domestic non-polluting sector. In this case, it may even be optimal to tax the use of capital in the polluting sector. It is also shown that it is always optimal to subsidise the use of capital in the polluting sector if the use of labour is taxed at an optimal rate. Finally, leakage does not affect the optimal domestic emission limit as long as appropriate capital subsidies and labour taxes are implementeed. (author)

  1. Remote laser detection of natural gas leakages from pipelines

    International Nuclear Information System (INIS)

    Petukhov, V O; Gorobets, V A; Andreev, Yu M; Lanskii, G V

    2010-01-01

    A differential absorption lidar based on a tunable TEA CO 2 laser emitting at 42 lines of the 'hot' 01 1 1 - 11 1 0 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h -1 and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)

  2. Hydrogeochemical Impact of CO2 Leakage from Geological Sequestration on Shallow Potable Aquifers

    DEFF Research Database (Denmark)

    Cahill, Aaron Graham

    . Although considered highly unlikely following appropriate site selection, leakage of CO2 from CCGS forms a major concern for both scientists and the public. Leakage would potentially occur through faults or abandoned boreholes and ultimately result in upward migration and discharge to the atmosphere....... During migration CO2 would dissolve into groundwater forming carbonic acid, induce water-rock reactions and thus change groundwater chemistry. Therefore prior to implementation of this potentially necessary technology, environmental risks associated with leakage must be understood. Over the past 10 years...... it be detected geochemically? Some common hydrochemical development is apparent from the literature however many aspects of hydrogeological and hydrogeochemical impact of leakage into shallow aquifers used in water supply remain unclear. In this Ph.D. study an integrated approach was employed in order to answer...

  3. Modeling the cosmic-ray-induced soft-error rate in integrated circuits: An overview

    International Nuclear Information System (INIS)

    Srinivasan, G.R.

    1996-01-01

    This paper is an overview of the concepts and methodologies used to predict soft-error rates (SER) due to cosmic and high-energy particle radiation in integrated circuit chips. The paper emphasizes the need for the SER simulation using the actual chip circuit model which includes device, process, and technology parameters as opposed to using either the discrete device simulation or generic circuit simulation that is commonly employed in SER modeling. Concepts such as funneling, event-by-event simulation, nuclear history files, critical charge, and charge sharing are examined. Also discussed are the relative importance of elastic and inelastic nuclear collisions, rare event statistics, and device vs. circuit simulations. The semi-empirical methodologies used in the aerospace community to arrive at SERs [also referred to as single-event upset (SEU) rates] in integrated circuit chips are reviewed. This paper is one of four in this special issue relating to SER modeling. Together, they provide a comprehensive account of this modeling effort, which has resulted in a unique modeling tool called the Soft-Error Monte Carlo Model, or SEMM

  4. Comment for nuclear data from the FNS integral experiments

    International Nuclear Information System (INIS)

    Maekawa, Hiroshi

    1983-01-01

    Among the integral experiments that were carried out during last one year at FNS, the following three experimental results and their analyses are discribed. 1) Tritium production-rate distribution in a Li 2 O-C assembly, 2) Angle dependent neutron leakage spectra from Li 2 O slab assemblies, 3) Induced activity of Type 316 stainless steel. (author)

  5. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    International Nuclear Information System (INIS)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja; Im, Hyoung June

    2010-01-01

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  6. Specific interaction of central nervous system myelin basic protein with lipids effects of basic protein on glucose leakage from liposomes

    NARCIS (Netherlands)

    Gould, R.M.; London, Y.

    1972-01-01

    The leakage from liposomes preloaded with glucose was continuously monitored in a Perkin-Elmer Model 356 dual beam spectrophotometer using an enzyme-linked assay system. The central nervous system myelin basic protein (A1 protein) caused a 3–4-fold increase in the rate of leakage from liposomes

  7. Incidence, risk factors, and treatment of pancreatic leakage after pancreaticoduodenectomy: drainage versus resection of the pancreatic remnant

    NARCIS (Netherlands)

    van Berge Henegouwen, M. I.; de Wit, L. T.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    1997-01-01

    BACKGROUND: Pancreatic leakage is a major cause of morbidity and mortality after pancreaticoduodenectomy, with incidences varying between 6-24% and a mortality rate up to 40%. Treatment is an issue of controversy. In this study we analyzed risk factors for pancreatic leakage and the results of early

  8. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  9. Regulatory concerns for leakage testing of packagings with three O-ring closure seals

    International Nuclear Information System (INIS)

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-01-01

    The American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) provides guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements and also provides guidance in determining appropriate acceptance criteria. Recent radioactive packagings designs have incorporated three O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results of leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can be caused in two ways, a large leakage in the containment seal or leakage in the inner seal. This paper will describe the problem together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packagings before a particular packaging design can be certified for transport

  10. Failure/leakage predictions of concrete structures containing cracks

    International Nuclear Information System (INIS)

    Pan, Y.C.; Marchertas, A.H.; Kennedy, J.M.

    1984-06-01

    An approach is presented for studying the cracking and radioactive release of a reactor containment during severe accidents and extreme environments. The cracking of concrete is modeled as the blunt crack. The initiation and propagation of a crack are determined by using the maximum strength and the J-integral criteria. Furthermore, the extent of cracking is related to the leakage calculation by using a model developed by Rizkalla, Lau and Simmonds. Numerical examples are given for a three-point bending problem and a hypothetical case of a concrete containment structure subjected to high internal pressure during an accident

  11. Distributed fiber optic system for oil pipeline leakage detection

    Science.gov (United States)

    Paranjape, R.; Liu, N.; Rumple, C.; Hara, Elmer H.

    2003-02-01

    We present a novel approach for the detection of leakage in oil pipelines using methods of fiber optic distributed sensors, a presence-of-oil based actuator, and Optical Time Domain Reflectometry (OTDR). While the basic concepts of our approach are well understood, the integration of the components into a complete system is a real world engineering design problem. Our focus has been on the development of the actuator design and testing using installed dark fiber. Initial results are promising, however environmental studies into the long term effects of exposure to the environment are still pending.

  12. Performance analysis of 60-min to 1-min integration time rain rate conversion models in Malaysia

    Science.gov (United States)

    Ng, Yun-Yann; Singh, Mandeep Singh Jit; Thiruchelvam, Vinesh

    2018-01-01

    Utilizing the frequency band above 10 GHz is in focus nowadays as a result of the fast expansion of radio communication systems in Malaysia. However, rain fade is the critical factor in attenuation of signal propagation for frequencies above 10 GHz. Malaysia is located in a tropical and equatorial region with high rain intensity throughout the year, and this study will review rain distribution and evaluate the performance of 60-min to 1-min integration time rain rate conversion methods for Malaysia. Several conversion methods such as Segal, Chebil & Rahman, Burgeono, Emiliani, Lavergnat and Gole (LG), Simplified Moupfouma, Joo et al., fourth order polynomial fit and logarithmic model have been chosen to evaluate the performance to predict 1-min rain rate for 10 sites in Malaysia. After the completion of this research, the results show that Chebil & Rahman model, Lavergnat & Gole model, Fourth order polynomial fit and Logarithmic model have shown the best performances in 60-min to 1-min rain rate conversion over 10 sites. In conclusion, it is proven that there is no single model which can claim to perform the best across 10 sites. By averaging RMSE and SC-RMSE over 10 sites, Chebil and Rahman model is the best method.

  13. Environmental and artificial tracers for investigating leakages into salt mines

    International Nuclear Information System (INIS)

    Zuber, A.; Grabczak, J.; Kolonko, M.

    1979-01-01

    The paper presents the results of five years of experience in investigating the origin of waters in the Wapno mine, where salt is exploited in a Zechstein dome, in northwestern Poland. Tritium and 14 C measurements showed young infiltration waters in leakages at the third level of the mine. Stable isotope determinations showed a considerable shift of values from the precipitation line, both on activity and on concentration scales. Despite this shift, it was possible to distinguish infiltration waters from connate ones appearing at deeper mine levels. In 1976 and 1977 leakage flow-rates increased and the mineralization decreased. Tritium and 14 C contents did not then change, showing that, at the initial stages of flooding, the origin of water in the leakages was not changed. The first results of isotope investigations in the Klodawa mine, situated in another Zechstein salt dome in central Poland, showed connate waters. Observations performed in the Wieliczka salt mine, situated in Miocene formations in southern Poland, showed old waters originating from the surrounding formations. Their stable isotope composition shows that recharge took place in a cooler climate. The 14 C content of these waters is 1 to 2% of recent carbon. The experimental procedure used to determine the isotopic composition of highly mineralized brines is also described. (author)

  14. Simulation of CO2 Sequestration at Rock Spring Uplift, Wyoming: Heterogeneity and Uncertainties in Storage Capacity, Injectivity and Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Hailin [Los Alamos National Laboratory; Dai, Zhenxue [Los Alamos National Laboratory; Jiao, Zunsheng [Wyoming State Geological Survey; Stauffer, Philip H. [Los Alamos National Laboratory; Surdam, Ronald C. [Wyoming State Geological Survey

    2011-01-01

    Many geological, geochemical, geomechanical and hydrogeological factors control CO{sub 2} storage in subsurface. Among them heterogeneity in saline aquifer can seriously influence design of injection wells, CO{sub 2} injection rate, CO{sub 2} plume migration, storage capacity, and potential leakage and risk assessment. This study applies indicator geostatistics, transition probability and Markov chain model at the Rock Springs Uplift, Wyoming generating facies-based heterogeneous fields for porosity and permeability in target saline aquifer (Pennsylvanian Weber sandstone) and surrounding rocks (Phosphoria, Madison and cap-rock Chugwater). A multiphase flow simulator FEHM is then used to model injection of CO{sub 2} into the target saline aquifer involving field-scale heterogeneity. The results reveal that (1) CO{sub 2} injection rates in different injection wells significantly change with local permeability distributions; (2) brine production rates in different pumping wells are also significantly impacted by the spatial heterogeneity in permeability; (3) liquid pressure evolution during and after CO{sub 2} injection in saline aquifer varies greatly for different realizations of random permeability fields, and this has potential important effects on hydraulic fracturing of the reservoir rock, reactivation of pre-existing faults and the integrity of the cap-rock; (4) CO{sub 2} storage capacity estimate for Rock Springs Uplift is 6614 {+-} 256 Mt at 95% confidence interval, which is about 36% of previous estimate based on homogeneous and isotropic storage formation; (5) density profiles show that the density of injected CO{sub 2} below 3 km is close to that of the ambient brine with given geothermal gradient and brine concentration, which indicates CO{sub 2} plume can sink to the deep before reaching thermal equilibrium with brine. Finally, we present uncertainty analysis of CO{sub 2} leakage into overlying formations due to heterogeneity in both the target saline

  15. Convexity and Weighted Integral Inequalities for Energy Decay Rates of Nonlinear Dissipative Hyperbolic Systems

    International Nuclear Information System (INIS)

    Alabau-Boussouira, Fatiha

    2005-01-01

    This work is concerned with the stabilization of hyperbolic systems by a nonlinear feedback which can be localized on a part of the boundary or locally distributed. We show that general weighted integral inequalities together with convexity arguments allow us to produce a general semi-explicit formula which leads to decay rates of the energy in terms of the behavior of the nonlinear feedback close to the origin. This formula allows us to unify for instance the cases where the feedback has a polynomial growth at the origin, with the cases where it goes exponentially fast to zero at the origin. We also give three other significant examples of nonpolynomial growth at the origin. We also prove the optimality of our results for the one-dimensional wave equation with nonlinear boundary dissipation. The key property for obtaining our general energy decay formula is the understanding between convexity properties of an explicit function connected to the feedback and the dissipation of energy

  16. 60-GHz integrated-circuit high data rate quadriphase shift keying exciter and modulator

    Science.gov (United States)

    Grote, A.; Chang, K.

    1984-01-01

    An integrated-circuit quadriphase shift keying (QPSK) exciter and modulator have demonstrated excellent performance directly modulating a carrier frequency of 60 GHz with an output phase error of less than 3 degrees and maximum amplitude error of 0.5 dB. The circuit consists of a 60-GHz Gunn VCO phase-locked to a low-frequency reference source, a 4th subharmonic mixer, and a QPSK modlator packaged into a small volume of 1.8 x 2.5 x 0.35 in. The use of microstrip has the advantages of small size, light-weight, and low-cost fabrication. The unit has the potential for multigigabit data rate applications.

  17. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication.

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  18. The PWR integrated leak rate test, a review of experiences and results

    International Nuclear Information System (INIS)

    Keogh, P.

    1985-01-01

    The paper reviews the Integrated Leak Rate Test (ILRT) as it has been carried out in the USA and as reported in papers in European countries. The test procedures are critically appraised and recommendations are given for modifications to them. The values used in a PWR are identified as a main source of leaks and possibilities for improvement are discussed. The use of a part pressure test and its limitations are considered. A part pressure test cannot give the same assurance as a full pressure test but may be useful for the identification of gross leaks. Secondary effects such as weather and the use of Van de Waals equations are considered and are found to be not important for concrete containments. (orig.)

  19. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  20. Translational and extensional energy release rates (the J- and M-integrals) for a crack layer in thermoelasticity

    Science.gov (United States)

    Chudnovsky, A.; Gommerstadt, B.

    1985-01-01

    A number of papers have been presented on the evaluation of energy release rate for thermoelasticity and corresponding J integral. Two main approaches were developed to treat energy release rate in elasticity. The first is based on direct calculation of the potential energy rate with respect to crack length. The second makes use of Lagrangian formalism. The translational and expansional energy release rates in thermoelasticity are studied by employing the formalism of irreversible thermodynamics and the Crack Layer Approach.

  1. An integrated approach for a higher success rate in mergers and acquisitions

    Directory of Open Access Journals (Sweden)

    Andrej Bertoncelj

    2007-05-01

    Full Text Available The paper outlines the importance of balanced management of hard and soft key success factors, combining the economic logic of corporate performance and human capital through an integrated approach to mergers and acquisitions. The study, based on a questionnaire and interviews, suggests that the achievement level ofmergers and acquisitions’ objectives of acquiring companies in Slovenia should be comparable to findings of similar studies; namely, the objectives that drove the deal were met only half the time. The results indicate that five hard success factors – a professional target search and due diligence, a realistic assessment of synergies, theright mix of financial sources, a detailed post-acquisition integration plan already prepared in the pre-deal phase and its speedy implementation – and five soft success factors – a new “combined” organizational culture, a competent management team, innovative employees, efficient and consistent communication and a creative business environment – are becoming increasingly relevant. Even though they differ in their importance for individual companies in the sample, they are all considered essential to increasing the success rate of corporate combinations

  2. Quantifying Effusion Rates at Active Volcanoes through Integrated Time-Lapse Laser Scanning and Photography

    Directory of Open Access Journals (Sweden)

    Neil Slatcher

    2015-11-01

    Full Text Available During volcanic eruptions, measurements of the rate at which magma is erupted underpin hazard assessments. For eruptions dominated by the effusion of lava, estimates are often made using satellite data; here, in a case study at Mount Etna (Sicily, we make the first measurements based on terrestrial laser scanning (TLS, and we also include explosive products. During the study period (17–21 July 2012, regular Strombolian explosions were occurring within the Bocca Nuova crater, producing a ~50 m-high scoria cone and a small lava flow field. TLS surveys over multi-day intervals determined a mean cone growth rate (effusive and explosive products of ~0.24 m3·s−1. Differences between 0.3-m resolution DEMs acquired at 10-minute intervals captured the evolution of a breakout lava flow lobe advancing at 0.01–0.03 m3·s−1. Partial occlusion within the crater prevented similar measurement of the main flow, but integrating TLS data with time-lapse imagery enabled lava viscosity (7.4 × 105 Pa·s to be derived from surface velocities and, hence, a flux of 0.11 m3·s−1 to be calculated. Total dense rock equivalent magma discharge estimates are ~0.1–0.2 m3·s−1 over the measurement period and suggest that simultaneous estimates from satellite data are somewhat overestimated. Our results support the use of integrated TLS and time-lapse photography for ground-truthing space-based measurements and highlight the value of interactive image analysis when automated approaches, such as particle image velocimetry (PIV, fail.

  3. Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

    International Nuclear Information System (INIS)

    Gentle, Jake Paul

    2016-01-01

    One primary goal of rendering today's transmission grid 'smarter' is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid's true capacity. With the 'Smarter Grid', new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation's energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL's DLR development supports EERE and The Wind Energy Technology Office's goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational Fluid Dynamics (CFD

  4. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  5. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  6. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  7. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  8. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  9. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  10. A 200 mV low leakage current subthreshold SRAM bitcell in a 130 nm CMOS process

    International Nuclear Information System (INIS)

    Bai Na; Lü Baitao

    2012-01-01

    A low leakage current subthreshold SRAM in 130 nm CMOS technology is proposed for ultra low voltage (200 mV) applications. Almost all of the previous subthreshold works ignore the leakage current in both active and standby modes. To minimize leakage, a self-adaptive leakage cut off scheme is adopted in the proposed design without any extra dynamic energy dissipation or performance penalty. Combined with buffering circuit and reconfigurable operation, the proposed design ensures both read and standby stability without deteriorating writability in the subthreshold region. Compared to the referenced subthreshold SRAM bitcell, the proposed bitcell shows: (1) a better critical state noise margin, and (2) smaller leakage current in both active and standby modes. Measurement results show that the proposed SRAM functions well at a 200 mV supply voltage with 0.13 μW power consumption at 138 kHz frequency. (semiconductor integrated circuits)

  11. Non-fistulous urinary leakage among women attending a Nigerian family planning clinic

    Directory of Open Access Journals (Sweden)

    Ijaiya MA

    2011-12-01

    Full Text Available Munir'deen A Ijaiya1, Hadijat O Raji1, Abiodun P Aboyeji1, Kike T Adesina1, Idowu O Adebara2, Grace G Ezeoke11Department of Obstetrics and Gynaecology, University of Ilorin Teaching Hospital, Ilorin, Nigeria; 2Department of Obstetrics and Gynaecology, Federal Medical Centre, Ido-Ekiti, NigeriaAbstract: Urinary leakage is an important gynecological challenge, which has a substantial impact on quality of life. The aim of this study was to determine the prevalence and types of non-fistulous urinary leakage among women attending the family planning clinic of the University of Ilorin teaching hospital, Ilorin, Nigeria. The study was a cross-sectional study carried out between January 3 and April 25 2009. One hundred and two women experienced urinary leakage out of 333 women interviewed, giving a prevalence rate of 30.6%. Stress incontinence was the most common urinary leakage (prevalence rate 12.0%. This is followed by urge incontinence (10.8%, urinary incontinence (4.8%, and overflow incontinence (3.0%. None of the women afflicted sought medical help. Conclusively, this study has demonstrated that non-fistulous urinary leakage is a common problem among women of reproductive age in this environment.Keywords: non-fistulous urinary leakage, family planning, women, prevalence, types

  12. Geologic Carbon Sequestration Leakage Detection: A Physics-Guided Machine Learning Approach

    Science.gov (United States)

    Lin, Y.; Harp, D. R.; Chen, B.; Pawar, R.

    2017-12-01

    One of the risks of large-scale geologic carbon sequestration is the potential migration of fluids out of the storage formations. Accurate and fast detection of this fluids migration is not only important but also challenging, due to the large subsurface uncertainty and complex governing physics. Traditional leakage detection and monitoring techniques rely on geophysical observations including pressure. However, the resulting accuracy of these methods is limited because of indirect information they provide requiring expert interpretation, therefore yielding in-accurate estimates of leakage rates and locations. In this work, we develop a novel machine-learning technique based on support vector regression to effectively and efficiently predict the leakage locations and leakage rates based on limited number of pressure observations. Compared to the conventional data-driven approaches, which can be usually seem as a "black box" procedure, we develop a physics-guided machine learning method to incorporate the governing physics into the learning procedure. To validate the performance of our proposed leakage detection method, we employ our method to both 2D and 3D synthetic subsurface models. Our novel CO2 leakage detection method has shown high detection accuracy in the example problems.

  13. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  14. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  15. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  16. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    Directory of Open Access Journals (Sweden)

    Kazeem B. Adedeji

    2017-10-01

    Full Text Available Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s of the network and the exact leaking pipelines connected to this segment(s where higher background leakage outflow occurs is a challenging task. Background leakage concerns the outflow from small cracks or deteriorated joints. In addition, because they are diffuse flow, they are not characterised by quick pressure drop and are not detectable by measuring instruments. Consequently, they go unreported for a long period of time posing a threat to water loss volume. Most of the existing research focuses on the detection and localisation of burst type leakages which are characterised by a sudden pressure drop. In this work, an algorithm for detecting and estimating background leakage in water distribution networks is presented. The algorithm integrates a leakage model into a classical WDN hydraulic model for solving the network leakage flows. The applicability of the developed algorithm is demonstrated on two different water networks. The results of the tested networks are discussed and the solutions obtained show the benefits of the proposed algorithm. A noteworthy evidence is that the algorithm permits the detection of critical segments or pipes of the network experiencing higher leakage outflow and indicates the probable pipes of the network where pressure control can be performed. However, the possible position of pressure control elements along such critical pipes will be addressed in future work.

  17. Use of integrity control and automatic start of reserve in a multi-channel temperature and flow rate control device

    International Nuclear Information System (INIS)

    Strzalkowski, L.

    1975-01-01

    A way to increase reliability of process quantity control is control of the integrity of the control plants themselves. The possibilities of integrity control on control devices having simply duplicated control channels or working on the basis of the ''two-from-three'' principle are valued. A highly reliable integrity control is possible by use of test signals. For an appropriate control device, structure and function of the assemblies are described. The integrity control device may be used in the water coolant temperature and flow rate control system for all technological channels of the research reactor ''Maria''

  18. Integrating river incision rates over timescales in the Ecuadorian Andes: from uplift history to current erosion rates

    Science.gov (United States)

    Campforts, Benjamin; Govers, Gerard; Vanacker, Veerle; Tenorio, Gustavo

    2013-04-01

    River profile development is studied at different timescales, from the response to uplift over millions of years over steady state erosion rates over millennia to the response to a single event, such as a major landslide. At present, few attempts have been made to compare data obtained over various timescales. Therefore we do not know to what extent data and model results are compatible: do long-term river profile development models yield erosion rates that are compatible with information obtained over shorter time spans, both in terms of absolute rates and spatial patterns or not? Such comparisons could provide crucial insights into the nature of river development and allow us to assess the confidence we may have when predicting river response at different timescales (e.g. Kirchner et al., 2001). A major issue hampering such comparison is the uncertainty involved in the calibration of long-term river profile development models. Furthermore, calibration data on different timescales are rarely available for a specific region. In this research, we set up a river profile development model similar to the one used by Roberts & White (2010) and successfully calibrated it for the northern Ecuadorian Andes using detailed uplift and sedimentological data. Subsequently we used the calibrated model to simulate river profile development in the southern Ecuadorian Andes. The calibrated model allows to reconstruct the Andean uplift history in southern Ecuador, which is characterized by a very strong uplift phase during the last 5 My. Erosion rates derived from the modeled river incision rates were then compared with 10Be derived basin-wide erosion rates for a series of basins within the study area. We found that the model-inferred erosion rates for the last millennia are broadly compatible with the cosmogenic derived denudation rates, both in terms of absolute erosion rates as well as in terms of their spatial distribution. Hence, a relatively simple river profile development

  19. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    Science.gov (United States)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  20. Use of coliform bacteria for the detection of on-line leakage in drinking water

    International Nuclear Information System (INIS)

    Bibi, S.; Karim, H.M.A.; Mashiatullah, A.; Sajjad, I.

    1996-01-01

    In this method, rupture or leakage in under ground water pipes is detected simply by taking the water samples from the main supply lines of the houses and incubating them at 40 deg. C for sixteen hours, colonies (developed with yellow colour) are counted with colony counter. Thirteen samples (in triplicate) collected from different houses in the congested localities during repair work of the major supply line and all of them after test showed heavy rate of pollution. The experiment was repeated for the same locality and sampling sites after completion of repair work. This time the rate of pollution decreases very much showing drastically low growth of microorganisms except for two points. For two further investigation of the nearly leakages at these points, 13 samples (in triplicate) were again collected in serial wise number of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of he pipes. This method is useful and causes no health hazard to the population and gives best results where the water supply is on intermittent basis. The technique is specially useful in the remote areas of the country where research facilities are not available and the Pacqualab is a field instrument. So it is handy and rapid method for the detection of leakage in underground water supplies in the remote areas of the country. (author)

  1. An integrated supply chain model for the perishable items with fuzzy production rate and fuzzy demand rate

    Directory of Open Access Journals (Sweden)

    Singh Chaman

    2011-01-01

    Full Text Available In the changing market scenario, supply chain management is getting phenomenal importance amongst researchers. Studies on supply chain management have emphasized the importance of a long-term strategic relationship between the manufacturer, distributor and retailer. In the present paper, a model has been developed by assuming that the demand rate and production rate as triangular fuzzy numbers and items deteriorate at a constant rate. The expressions for the average inventory cost are obtained both in crisp and fuzzy sense. The fuzzy model is defuzzified using the fuzzy extension principle, and its optimization with respect to the decision variable is also carried out. Finally, an example is given to illustrate the model and sensitivity analysis is performed to study the effect of parameters.

  2. Poloidal field leakage optimization in ETE

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Carlos Shinya; Montes, Antonio

    1996-12-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs.

  3. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  5. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  6. Poloidal field leakage optimization in ETE

    International Nuclear Information System (INIS)

    Shibata, Carlos Shinya; Montes, Antonio.

    1996-01-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs

  7. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  8. Safe transport of radioactive materials - Leakage testing on packages. 1. ed.

    International Nuclear Information System (INIS)

    1996-01-01

    This International Standard describes a method for relating permissible activity release rates of the radioactive contents carried within a containment system to equivalent gas leakage rates under specified test conditions. This approach is called gas leakage test methodology. However, in this International Standard it is recognized that other methodologies might be acceptable. When other methodologies are to be used, it shall be shown that the methodology demonstrates that any release of the radioactive contents will not exceed the regulatory requirements. The use of any alternative methodology shall be by agreement with the competent authority. This International Standard provides both overall and detailed guidance on the complex relationships between an equivalent gas leakage test and a permissible activity release rate. Whereas the overall guidance is universally agreed upon, the use of the detailed guidance shall be agreed upon with the competent authority during the Type B package certification process. It should be noted that, for a given package, demonstration of compliance is not limited to a single methodology. While this International Standard does not require particular gas leakage test procedures, it does present minimum requirements for any test that is to be used. It is the responsibility of the package designer or consignor to estimate or determine the maximum permissible release rate of radioactivity to the environment and to select appropriate leakage test procedures that have adequate sensitivity. This International Standard pertains specifically to Type B packages for which the regulatory containment requirements are specified explicitly

  9. Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Jake Paul [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-12-01

    One primary goal of rendering today’s transmission grid “smarter” is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid’s true capacity. With the “Smarter Grid”, new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation’s energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL’s DLR development supports EERE and The Wind Energy Technology Office’s goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational

  10. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  12. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States); Shaffer, M. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  13. Leakage Reduction in Water Distribution Systems with Efficient Placement and Control of Pressure Reducing Valves Using Soft Computing Techniques

    Directory of Open Access Journals (Sweden)

    A. Gupta

    2017-04-01

    Full Text Available Reduction of leakages in a water distribution system (WDS is one of the major concerns of water industries. Leakages depend on pressure, hence installing pressure reducing valves (PRVs in the water network is a successful techniques for reducing leakages. Determining the number of valves, their locations, and optimal control setting are the challenges faced. This paper presents a new algorithm-based rule for determining the location of valves in a WDS having a variable demand pattern, which results in more favorable optimization of PRV localization than that caused by previous techniques. A multiobjective genetic algorithm (NSGA-II was used to determine the optimized control value of PRVs and to minimize the leakage rate in the WDS. Minimum required pressure was maintained at all nodes to avoid pressure deficiency at any node. Proposed methodology is applied in a benchmark WDS and after using PRVs, the average leakage rate was reduced by 6.05 l/s (20.64%, which is more favorable than the rate obtained with the existing techniques used for leakage control in the WDS. Compared with earlier studies, a lower number of PRVs was required for optimization, thus the proposed algorithm tends to provide a more cost-effective solution. In conclusion, the proposed algorithm leads to more favorable optimized localization and control of PRV with improved leakage reduction rate.

  14. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun [Radiation Eng. Center, Shihung (Korea, Republic of); Lee, Dongbum [Academic Support Dept., Seoul (Korea, Republic of)

    2013-05-15

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  15. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  16. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    International Nuclear Information System (INIS)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun; Lee, Dongbum

    2013-01-01

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  17. Fast breeder reactors secondary piping potential sodium leakage rate assessment

    International Nuclear Information System (INIS)

    Alicino, F.; Cardini, S.

    1989-01-01

    In the liquid metal fast breeder reactors (LMFBRs) it must always be taken under control any possible air-sodium contact, because of the elevated air-sodium reactivity. This requires that LMFBRs be carefully designed so that over the entire plant life such an event can't occur in an uncontrolled way. For these reactors the operating conditions usually impose that a lot of life be spent in the creep regime and moreover generally severe hot and cold thermal transients are anticipated, which increases the potential of crack propagation. Then, a useful means to ascertain if this event can occur is to adopt a fracture mechanics approach. This paper presents a computer program to perform fracture mechanics calculations

  18. Secret-key rates and privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.

    2009-01-01

    In this thesis both the generation of secret keys from biometric data and the binding of secret keys to biometric data are investigated. These secret keys can be used to regulate access to sensitive data, services, and environments. In a biometric secrecy system a secret key is generated or chosen

  19. Diagnoses, Intervention Strategies, and Rates of Functional Improvement in Integrated Behavioral Health Care Patients

    Science.gov (United States)

    Bridges, Ana J.; Gregus, Samantha J.; Rodriguez, Juventino Hernandez; Andrews, Arthur R.; Villalobos, Bianca T.; Pastrana, Freddie A.; Cavell, Timothy A.

    2016-01-01

    Objective Compared with more traditional mental health care, integrated behavioral health care (IBHC) offers greater access to services and earlier identification and intervention of behavioral and mental health difficulties. The current study examined demographic, diagnostic, and intervention factors that predict positive changes for IBHC patients. Method Participants were 1,150 consecutive patients (mean age = 30.10 years, 66.6% female, 60.1% Hispanic, 47.9% uninsured) seen for IBHC services at 2 primary care clinics over a 34-month period. Patients presented with depressive (23.2%), anxiety (18.6%), adjustment (11.3%), and childhood externalizing (7.6%) disorders, with 25.7% of patients receiving no diagnosis. Results The most commonly delivered interventions included behavioral activation (26.1%), behavioral medicine-specific consultation (14.6%), relaxation training (10.3%), and parent-management training (8.5%). There was high concordance between diagnoses and evidence-based intervention selection. We used latent growth curve modeling to explore predictors of baseline global assessment of functioning (GAF) and improvements in GAF across sessions, utilizing data from a subset of 117 patients who attended at least 3 behavioral health visits. Hispanic ethnicity and being insured predicted higher baseline GAF, while patients with an anxiety disorder had lower baseline GAF than patients with other diagnoses. Controlling for primary diagnosis, patients receiving behavioral activation or exposure therapy improved at faster rates than patients receiving other interventions. Demographic variables did not relate to rates of improvement. Conclusion Results suggest even brief IBHC interventions can be focused, targeting specific patient concerns with evidence-based treatment components. PMID:25774786

  20. AN ADVANCED LEAKAGE SCHEME FOR NEUTRINO TREATMENT IN ASTROPHYSICAL SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Perego, A. [Institut für Kernphysik, Technische Universität Darmstadt, Schlossgartenstraße 2, D-64289 Darmstadt (Germany); Cabezón, R. M. [Physics Department, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Käppeli, R., E-mail: albino.perego@physik.tu-darmstadt.de [Seminar for Applied Mathematics, ETH Zürich, Rämistrasse 101, 8092 Zürich (Switzerland)

    2016-04-15

    We present an Advanced Spectral Leakage (ASL) scheme to model neutrinos in the context of core-collapse supernovae (CCSNe) and compact binary mergers. Based on previous gray leakage schemes, the ASL scheme computes the neutrino cooling rates by interpolating local production and diffusion rates (relevant in optically thin and thick regimes, respectively) separately for discretized values of the neutrino energy. Neutrino trapped components are also modeled, based on equilibrium and timescale arguments. The better accuracy achieved by the spectral treatment allows a more reliable computation of neutrino heating rates in optically thin conditions. The scheme has been calibrated and tested against Boltzmann transport in the context of Newtonian spherically symmetric models of CCSNe. ASL shows a very good qualitative and a partial quantitative agreement for key quantities from collapse to a few hundreds of milliseconds after core bounce. We have proved the adaptability and flexibility of our ASL scheme, coupling it to an axisymmetric Eulerian and to a three-dimensional smoothed particle hydrodynamics code to simulate core collapse. Therefore, the neutrino treatment presented here is ideal for large parameter-space explorations, parametric studies, high-resolution tests, code developments, and long-term modeling of asymmetric configurations, where more detailed neutrino treatments are not available or are currently computationally too expensive.

  1. A Comparative Risk Assessment of Extended Integrated Leak Rate Testing Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji Yong; Hwang, Seok Won; Lee, Byung Sik [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2009-10-15

    This paper presents the risk impacts of extending the Integrated Leak Rate Testing (ILRT) intervals (from five years to ten years) of Yonggwang (YGN) Unit 1 and 2. These risk impacts depended on the annual variances of meteorological data and resident population. Main comparisons were performed between the initial risk assessment (2005) for the purpose of extending ILRT interval and risk reassessment (2009) where the changed plant internal configurations (core inventory and radioisotope release fraction) and plant external alterations (wind directions, rainfall and population distributions) were monitored. The reassessment showed that there was imperceptible risk increase when the ILRT interval was extended compared to the initial risk assessment. In addition, the increased value of the Large Early Release Frequency (LERF) also satisfied the acceptance guideline proposed on Reg. Guide 1.174. The MACCS II code was used for evaluating the offsite consequence analysis. The primary risk index were used as the Probabilistic Population Dose (PPD) by considering the early effects within 80 km. The Probabilistic Safety Assessment (PSA) of YGN 1 and 2 was applied to evaluate the accident frequency of each source term category and the used PSA scope was limited to internal event.

  2. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Multimedia

    Liberali, V; Rizzi, A; Re, V; Minuti, M; Pangaud, P; Barbero, M B; Pacher, L; Kluit, R; Hinchliffe, I; Manghisoni, M; Giubilato, P; Faccio, F; Pernegger, H; Krueger, H; Gensolen, F D; Bilei, G M; Da rocha rolo, M D; Prydderch, M L; Fanucci, L; Grillo, A A; Bellazzini, R; Palomo pinto, F R; Michelis, S; Huegging, F G; Kishishita, T; Marchiori, G; Christian, D C; Kaestli, H C; Meier, B; Andreazza, A; Key-charriere, M; Linssen, L; Dannheim, D; Conti, E; Hemperek, T; Menouni, M; Fougeron, D; Genat, J; Bomben, M; Marzocca, C; Demaria, N; Mazza, G; Van bakel, N A; Palla, F; Grippo, M T; Magazzu, G; Ratti, L; Abbaneo, D; Crescioli, F; Deptuch, G W; Neue, G; De robertis, G; Passeri, D; Placidi, P; Gromov, V; Morsani, F; Paccagnella, A; Christiansen, J; Dho, E; Wermes, N; Rymaszewski, P; Rozanov, A; Wang, A; Lipton, R J; Havranek, M; Neviani, A; Marconi, S; Karagounis, M; Godiot, S; Calderini, G; Seidel, S C; Horisberger, R P; Garcia-sciveres, M A; Stabile, A; Beccherle, R; Bacchetta, N

    The present hybrid pixel detectors in operation at the LHC represent a major achievement. They deployed a new technology on an unprecedented scale and their success firmly established pixel tracking as indispensable for future HEP experiments. However, extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. We propose a new RD collaboration specifically focused on the development of pixel readout Integrated Circuits (IC). The IC challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm$^{2}$), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. We propose a collaboration to design the next generation of hybrid pixel readout chips to enable the ATLAS and CMS Phase 2 pixel upgrades. This does not imply that ATLAS and CMS must use the same exact pixel readout chip, as most of the dev...

  3. Comparison of apical leakage between immediate versus delayed post space preparation using two resin sealers

    Directory of Open Access Journals (Sweden)

    Priyanka Kaushal Kalra

    2009-01-01

    Full Text Available Post & Core Procedures have became an integral part of a dentist′s arsenal. This study was carried out in order to assess the microleakage when immediate and delayed post space preparations were done using resin sealers. Immediate post space preparations showed lesser apical leakage as opposed to delayed post space preparation.

  4. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  5. Air-steam leakage through cracks in concrete

    International Nuclear Information System (INIS)

    Georges Nahas; Helene Simon

    2005-01-01

    Full text of publication follows: In the context of a severe accident in a Pressurised Water nuclear plant, the evaluation of the leakage rate through the containment wall remains a key point of the safety analysis, because it influences directly the consequences on the environment. During a severe accident, large amounts of steam could be released in the containment; internal pressure could rise beyond design limits causing cracks to appear in the internal concrete wall of the double-wall containment and fission products to leak towards the containment annulus. A research program led by the French Institute for Radiological Protection and Nuclear Safety aims to estimate this leakage. In the presence of cracks, most of the leak flows through them. Hence, a first phase of the program was to build a two-phase homogeneous model for the flow of an air-steam mixture through a idealized traversing crack, taking into account condensation phenomena, and considering crack openings from 25 μm to several hundred μm. A numerical model for the flow, coupled with heat transfer in the wall, was implemented in the Finite Element code CAST3M. This model was validated on a small scaled experiment which was made of two parallel glass plates. Comparison of the numerical and experimental results in this 'channel case' has shown good results for the total mass flow rate for channel openings greater than 100 μm. For the 50 μm opening the calculation gave a 50 % estimate of the experimental total mass flow rate. The second phase of the program is now to validate the model on cracks performed in a concrete specimen. In order to do so, we have simulated the experiment VK2/2 described in the article named 'Investigation of the leakage behavior of reinforced concrete walls' by N. Herrmann, C. Niklasch, M. Stegemann, L. Stempniewski. The reinforced concrete slab, 2.7 m long in the reinforcement direction and 1.2 m thick in the cracking direction, is placed in a mechanical set-up and an

  6. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  7. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  8. Examination of leakage aspects through concrete - steel interfaces at and around containment penetration assemblies

    International Nuclear Information System (INIS)

    Chakrabarti, S.K.; Sai, A.S.R.; Basu, P.C.

    1994-01-01

    Penetration assemblies are parts required to be provided in the containment wall/dome to permit piping, mechanical devices, equipments, electrical cables, personnel movements etc. Integrity of arrangements with respect to leak tightness at or around these penetration assemblies, is of utmost importance for achieving safe functioning of containment. Considering the feasibilities in controlling leakages along different possible paths, it has been found necessary to examine in detail the leakage possibilities at concrete - steel interfaces at and around penetration assemblies. The present paper addresses this issue with respect to the important related aspects like constructional details, testing conditions, normal operating conditions, and the accidental situation associated with containment structures. (author)

  9. Model-based monitoring techniques for leakage localization in distribution water networks

    OpenAIRE

    Meseguer Amela, Jordi; Mirats Tur, Josep Maria; Cembrano Gennari, Gabriela; Puig Cayuela, Vicenç

    2015-01-01

    This is an open access article under the CC BY-NC-ND license This paper describes an integrated model-based monitoring framework for leakage localization in district-metered areas (DMA) of water distribution networks, which takes advantage of the availability of a hydraulic model of the network. The leakage localization methodology is based on the use of flow and pressure sensors at the DMA inlets and a limited number of pressure sensors deployed inside the DMA. The placement of these sens...

  10. Accelerated fuel depreciation as an economic incentive for low-leakage fuel management

    International Nuclear Information System (INIS)

    Downar, T.J.

    1986-01-01

    An analysis is presented which evaluates the tax depreciation advantage which results from the increased rate of fuel depletion achieved in the current low-leakage fuel-management LWR core reload designs. An analytical fuel-cycle cost model is used to examine the important cost parameters which are then validated using the fuel-cycle cost code CINCAS and data from the Maine Yankee PWR. Results show that low-leakage fuel management, through the tax depreciation advantage from accelerated fuel depletion, provides an improvement of several percent in fuel-cycle costs compared to traditional out-in fuel management and a constant fuel depletion rate. (author)

  11. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  12. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection.

    Science.gov (United States)

    Martin, Douglas J; Rad, Arash Ehteshami; Kallmes, David F

    2012-06-01

    Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, postprocedure plain radiographs, and postprocedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and prevertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ(2) test. One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34%, 95% CI 28-42%) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P = 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n = 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and prevertebral venous (n = 32, 18%, 95% CI 13-24%). Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography.

  13. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection

    International Nuclear Information System (INIS)

    Martin, Douglas J.; Rad, Arash Ehteshami; Kallmes, David F.

    2012-01-01

    Background: Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. Purpose: To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, post procedure plain radiographs, and post procedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. Material and Methods: With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and pre vertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ 2 test. Results: One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34 %, 95 % CI 28-42 %) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and pre vertebral venous (n = 32, 18%, 95% CI 13-24%). Conclusion: Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography

  14. Rating Requirements of the UPQC to Integrate the FSIG Type Wind Generation to the Grid

    OpenAIRE

    Jayanti, N.; Basu, Malabika; Conlon, Michael; Gaughan, Kevin

    2009-01-01

    The ability of wind generation to remain connected to the grid in the event of system faults and dynamic reactive power compensation are two aspects of grid integration, which have received particular attention. The wind driven, fixed-speed induction generator (FSIG) on its own fails to fulfil these requirements of grid integration. The application of a unified power quality conditioner (UPQC) to overcome the grid integration problems of the FSIG is investigated. The role of the UPQC in enhan...

  15. Leakage current measurements on pixelated CdZnTe detectors

    International Nuclear Information System (INIS)

    Dirks, B.P.F.; Blondel, C.; Daly, F.; Gevin, O.; Limousin, O.; Lugiez, F.

    2006-01-01

    In the field of the R and D of a new generation hard X-ray cameras for space applications we focus on the use of pixelated CdTe or CdZnTe semiconductor detectors. They are covered with 64 (0.9x0.9 mm 2 ) or 256 (0.5x0.5 mm 2 ) pixels, surrounded by a guard ring and operate in the energy ranging from several keV to 1 MeV, at temperatures between -20 and +20 o C. A critical parameter in the characterisation of these detectors is the leakage current per pixel under polarisation (∼50-500 V/mm). In operation mode each pixel will be read-out by an integrated spectroscopy channel of the multi-channel IDeF-X ASIC currently developed in our lab. The design and functionality of the ASIC depends directly on the direction and value of the current. A dedicated and highly insulating electronics circuit is designed to automatically measure the current in each individual pixel, which is in the order of tens of pico-amperes. Leakage current maps of different CdZnTe detectors of 2 and 6 mm thick and at various temperatures are presented and discussed. Defect density diagnostics have been performed by calculation of the activation energy of the material

  16. Influence of radiation exposure rate on somatic mutation frequency and loss of reproductive integrity in tradescantia stamen hairs

    International Nuclear Information System (INIS)

    Ichikawa, S.; Nauman, C.H.; Sparrow, A.H.; Takahashi, C.S.

    1978-01-01

    Inflorescences of Tradescantia clone 02 (2n=12), hetero- or hemi-zygous for flower color, were exposed to a series of γ-ray exposures at two different exposure rates, 29.3 R/min and 0.026-0.52 R/min. Pink mutation-response curves, and survival curves based on reproductive integrity, were constructed for each of the exposure rates. Loss of reproductive integrity was also assessed at high (256 R/min) and low (0.52-4.17 R/min) γ-ray exposure rates in T. blossfeldiana (2n=72). All observations were made on stamen hairs. The higher exposure rate was 1.3-1.7 times more effective in inducing pink mutations in clone 02. A greater efficiency of the higher exposure rate was also found for both taxa at the loss of reproductive integrity endpoint. The D 0 values obtained at the higher exposure rates, 154 R for clone 02 and 720 R for T. blossfeldiana, were significantly lower than the corresponding values of 270 R and 1880 R obtained at the lower exposure rates. These D 0 's differ by factors of 1.75 and 2.61 for clone 02 and T. blossfeldiana, respectively. D 0 's for the two taxa were found to be inversely correlated with their interphase chromosome volumes. (Auth.)

  17. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  18. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  19. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  20. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  1. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  2. Anastomotic leakage after low anterior resection for rectal cancer. Facts, obscurity, and fiction

    International Nuclear Information System (INIS)

    Taflampas, P.; Christodoulakis, M.; Tsiftsis, D.D.

    2009-01-01

    The subject of anastomotic leakage after low anterior resection (LAR) for rectal cancer remains controversial. Risk factors have been discussed in several studies but the findings are often inconclusive. This review evaluates these studies and separates the known risk factors into those that are well documented, those that are obsolete, and those that require further research. We searched the Medline and PubMed databases using the keywords: leakage,' 'low anterior resection,' 'rectal cancer,' 'risk factors,' and their combinations. There were no language or publication year restrictions. References in published papers were also reviewed. Each risk factor was evaluated and discussed separately. The evidence suggests that low anastomoses are more prone to leakage. Other well-documented risk factors are male sex, smoking, and preoperative malnutrition. Routine mobilization of the splenic flexure and the use of a J-pouch seem to reduce the leakage rate. The effect of preoperative chemo-radiotherapy is under scrutiny. The indications for a protective stoma remain debatable. Omentoplasty, bowel preparation, the use of a drain, and tumor stage do not seem to affect the leakage rate. The type of operation (open or laparoscopic) and anastomosis (hand-sewn or stapled) is not crucial. (author)

  3. Monitoring device for radioactive leakage from steam system in nuclear power plant

    International Nuclear Information System (INIS)

    Ogawa, Tateo; Sato, Kohei

    1988-01-01

    Purpose: To improve the reliability for the monitor of radio-active leakage by accumulating small quantity of radioactivities each lower than the detectable level and increasing their dose rate. Constitution: Even if the steam system radiation monitor in the nuclear power plant is disposed for the detection of in-leak radioactivity, radioactive leakage can be monitored at high reliability by increasing the small quantity of radioactivities in the drains to a detectable sensitivity range of the monitor upon detection. In view of the above, in the present invention, radioactive material catching medium is incorporated to a radio-activity monitor spool piece for accumulating small quantity of radioactivities. Specifically as the catching medium, an ion exchange resin is used for the leakage of ionic radioactive material, while an ion exchange resin increased with the mixing ratio of a cationic resin or hollow thread membrane filter is used for crud-like radioactive material leakage. These catching media are incorporated into the spool piece, thereby enabling to catch even small quantity of radioactive leakage lower than the detectable sensitivity of the radiation monitor, if should occur, in the spool piece and enabling radioactive detection for the accumulated dose rate. (Horiuchi, T.)

  4. Reactor dosimetry integral reaction rate data in LMFBR Benchmark and standard neutron fields: status, accuracy and implications

    International Nuclear Information System (INIS)

    Fabry, A.; Ceulemans, H.; Vandeplas, P.; McElroy, W.N.; Lippincott, E.P.

    1977-01-01

    This paper provides conclusions that may be drawn regarding the consistency and accuracy of dosimetry cross-section files on the basis of integral reaction rate data measured in U.S. and European benchmark and standard neutron fields. In a discussion of the major experimental facilities CFRMF (Idaho Falls), BIGTEN (Los Alamos), ΣΣ (Mol, Bucharest), NISUS (London), TAPIRO (Roma), FISSION SPECTRA (NBS, Mol, PTB), attention is paid to quantifying the sensitivity of computed integral data relative to the presently evaluated accuracy of the various neutron spectral distributions. The status of available integral data is reviewed and the assigned uncertainties are appraised, including experience gained by interlaboratory comparisons. For all reactions studied and for the various neutron fields, the measured integral data are compared to the ones computed from the ENDF/B-IV and the SAND-II dosimetry cross-section libraries as well as to some other differential data in relevant cases. This comparison, together with the proposed sensitivity and accuracy assessments, is used, whenever possible, to establish how well the best cross-sections evaluated on the basis of differential measurements (category I dosimetry reactions) are reliable in terms of integral reaction rates prediction and, for those reactions for which discrepancies are indicated, in which energy range it is presumed that additional differential measurements might help. For the other reactions (category II), the inconsistencies and trends are examined. The need for further integral measurements and interlaboratory comparisons is also considered

  5. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  6. Exergy analysis of integrated photovoltaic thermal solar water heater under constant flow rate and constant collection temperature modes

    NARCIS (Netherlands)

    Tiwari, A.; Dubey, Swapnil; Sandhu, G.S.; Sodha, M.S.; Anwar, S.I.

    2009-01-01

    In this communication, an analytical expression for the water temperature of an integrated photovoltaic thermal solar (IPVTS) water heater under constant flow rate hot water withdrawal has been obtained. Analysis is based on basic energy balance for hybrid flat plate collector and storage tank,

  7. A bit-rate flexible and power efficient all-optical demultiplexer realised by monolithically integrated Michelson interferometer

    DEFF Research Database (Denmark)

    Vaa, Michael; Mikkelsen, Benny; Jepsen, Kim Stokholm

    1996-01-01

    A novel bit-rate flexible and very power efficient all-optical demultiplexer using differential optical control of a monolithically integrated Michelson interferometer with MQW SOAs is demonstrated at 40 to 10 Gbit/s. Gain switched DFB lasers provide ultra stable data and control signals....

  8. Cyclo-oxygenase 2 inhibitors and the risk of anastomotic leakage after fast-track colonic surgery

    DEFF Research Database (Denmark)

    Holte, K; Andersen, Jens; Jakobsen, D Hjort

    2009-01-01

    -oxygenase inhibitor for postoperative analgesia. METHODS: Patients with anastomotic leakage following a standard fast-track procotol between April 1997 and May 2006 were identified from a prospective, consecutive database. During this period there were two changes in perioperative management: cessation......BACKGROUND: Anastomotic leakage occurs after 3-6 per cent of colonic resections. The influence of analgesic agents is largely unknown. This study determined the rate of anastomotic leakage in a series of patients who had colonic surgery over a 9-year period with or without use of a cyclo...

  9. Change regularity of water quality parameters in leakage flow conditions and their relationship with iron release.

    Science.gov (United States)

    Liu, Jingqing; Shentu, Huabin; Chen, Huanyu; Ye, Ping; Xu, Bing; Zhang, Yifu; Bastani, Hamid; Peng, Hongxi; Chen, Lei; Zhang, Tuqiao

    2017-11-01

    The long-term stagnation in metal water supply pipes, usually caused by intermittent consumption patterns, will cause significant iron release and water quality deterioration, especially at the terminus of pipelines. Another common phenomenon at the terminus of pipelines is leakage, which is considered helpful by allowing seepage of low-quality drinking water resulting from long-term stagnation. In this study, the effect of laminar flow on alleviating water quality deterioration under different leakage conditions was investigated, and the potential thresholds of the flow rate, which can affect the iron release process, were discussed. Based on a galvanized pipe and ductile cast iron pipe pilot platform, which was established at the terminus of pipelines, this research was carried out by setting a series of leakage rate gradients to analyze the influence of different leakage flow rates on iron release, as well as the relationship with chemical and biological parameters. The results showed that the water quality parameters were obviously influenced by the change in flow velocity. Water quality was gradually improved with an increase in flow velocity, but its change regularity reflected a diversity under different flow rates (p water distribution system, when the bulk water was at the critical laminar flow velocity, the concentration of total iron, the quantity and rate of total iron release remain relatively in an ideal and safe situation. Copyright © 2017. Published by Elsevier Ltd.

  10. Numerical Modeling of Methane Leakage from a Faulty Natural Gas Well into Fractured Tight Formations.

    Science.gov (United States)

    Moortgat, Joachim; Schwartz, Franklin W; Darrah, Thomas H

    2018-03-01

    Horizontal drilling and hydraulic fracturing have enabled hydrocarbon recovery from unconventional reservoirs, but led to natural gas contamination of shallow groundwaters. We describe and apply numerical models of gas-phase migration associated with leaking natural gas wells. Three leakage scenarios are simulated: (1) high-pressure natural gas pulse released into a fractured aquifer; (2) continuous slow leakage into a tilted fractured formation; and (3) continuous slow leakage into an unfractured aquifer with fluvial channels, to facilitate a generalized evaluation of natural gas transport from faulty natural gas wells. High-pressure pulses of gas leakage into sparsely fractured media are needed to produce the extensive and rapid lateral spreading of free gas previously observed in field studies. Transport in fractures explains how methane can travel vastly different distances and directions laterally away from a leaking well, which leads to variable levels of methane contamination in nearby groundwater wells. Lower rates of methane leakage (≤1 Mcf/day) produce shorter length scales of gas transport than determined by the high-pressure scenario or field studies, unless aquifers have low vertical permeabilities (≤1 millidarcy) and fractures and bedding planes have sufficient tilt (∼10°) to allow a lateral buoyancy component. Similarly, in fractured rock aquifers or where permeability is controlled by channelized fluvial deposits, lateral flow is not sufficiently developed to explain fast-developing gas contamination (0-3 months) or large length scales (∼1 km) documented in field studies. Thus, current efforts to evaluate the frequency, mechanism, and impacts of natural gas leakage from faulty natural gas wells likely underestimate contributions from small-volume, low-pressure leakage events. © 2018, National Ground Water Association.

  11. Abdominal Drainage and Amylase Measurement for Detection of Leakage After Gastrectomy for Gastric Cancer.

    Science.gov (United States)

    Schots, Judith P M; Luyer, Misha D P; Nieuwenhuijzen, Grard A P

    2018-05-07

    To investigate the value of daily measurement of drain amylase for detecting leakage in gastric cancer surgery. This was a retrospective analysis including all patients who underwent a gastrectomy for gastric cancer. From January 2013 until December 2015, an intra-abdominal drain was routinely placed. Drain amylase was measured daily. Receiver operator characteristic curves were created to assess the ability of amylase to predict leakage. Sensitivity, specificity, and negative and positive predictive value of amylase in drain fluid were determined. Leakage of the gastrojejunostomy or esophagojejunostomy, enteroenterostomy, duodenal stump, or pancreas was diagnosed by CT scan, endoscopy, or during re-operation. From January 2016 until April 2017, no drain was inserted. Surgical outcome and postoperative complications were compared between both groups. Median drain amylase concentrations were higher for each postoperative day in patients with leakage. The optimal cutoff value was 1000 IU/L (sensitivity 77.8%, specificity 98.2%, negative predictive value 96.6%). Sixty-seven consecutive procedures were performed with a drain and 40 procedures without. No differences in group characteristics were observed except for gender. Fourteen patients (13.1%) had a leakage. The incidence and severity of leakage were not different between the patients with and without a drain. There was no significant difference in time to diagnosis (1 vs. 0 days; p 0.34), mortality rate (7.5 vs. 2.5%; p 0.41), and median length of hospital stay (9 days in both groups; p 0.46). Daily amylase measurement in drain fluid does not influence the early recognition and management of leakage in gastric cancer surgery.

  12. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  13. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Garcia-Sciveres, M; CERN. Geneva. The LHC experiments Committee; LHCC

    2013-01-01

    Letter of Intent for RD Collaboration Proposal focused on development of a next generation pixel readout integrated circuits needed for high luminosity LHC detector upgrades. Brings together ATLAS and CMS pixel chip design communities.

  14. Rapid measurement of blood leakage during regional chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, C. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Nuklearmedizin); Omlor, G.; Gross, G.; Feifel, G. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Allgemeine Chirurgie); Berberich, R. (Staedtische Klinik Wuppertal (Germany). Abt. fuer Nuklearmedizin)

    1993-03-01

    A method using technetium-99m in vivo red blood cell (RBC) labelling is reported that provides results within 3 min. Blood samples drawn from the systemic and the extracorporeal circulation were measured for [sup 99m]Tc activity using a mobile well counter, and the leakage values calculated. The mean result was 7.6%[+-]6.5%/15 min (n=209). The corresponding flow rate was 100.2[+-]85.7 ml/15 min. The values for isolation perfusion of the upper and the lower extremities are compared. The leakage results using [sup 99m]Tc RBC labelling were correlated with other blood pool markers. Iodine-125 human serum albumin and indium-113 m transferrin were administered in subgroups of 4 and 19 patients simultaneously. Using linear regression, the coefficient of correlation was 0.72 for [sup 99m]Tc/[sup 113m]In and 0.58 for [sup 99m]Tc/[sup 125]I. Comparison with the alternatives suggests that the method can be considered one of the most practicable and reliable methods available. (orig.).

  15. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  16. Antimicrobial Peptide Lactoferricin B-Induced Rapid Leakage of Internal Contents from Single Giant Unilamellar Vesicles.

    Science.gov (United States)

    Moniruzzaman, Md; Alam, Jahangir Md; Dohra, Hideo; Yamazaki, Masahito

    2015-09-29

    Enzymatic digestion of bovine lactoferrin generates lactoferricin B (Lfcin B), a 25-mer peptide with strong antimicrobial activity of unknown mechanism. To elucidate the mechanistic basis of Lfcin B bactericidal activity, we investigated the interaction of Lfcin B with Escherichia coli and liposomes of lipid membranes. Lfcin B induced the influx of a membrane-impermeant fluorescent probe, SYTOX green, from the outside of E. coli into its cytoplasm. Lfcin B induced gradual leakage of calcein from large unilamellar vesicles (LUVs) of dioleoylphosphatidylglycerol (DOPG)/dioleoylphosphatidylcholine (DOPC) membranes. To clarify the cause of Lfcin B-induced leakage of calcein from the LUVs, we used the single giant unilamellar vesicle (GUV) method to investigate the interaction of Lfcin B with calcein-containing DOPG/DOPC-GUVs. We observed that a rapid leakage of calcein from a GUV started stochastically; statistical analysis provided a rate constant for Lfcin B-induced pore formation, kp. On the other hand, phase-contrast microscopic images revealed that Lfcin B induced a rapid leakage of sucrose from the single GUVs with concomitant appearance of a spherical GUV of smaller diameter. Because of the very fast leakage, and at the present time resolution of the experiments (33 ms), we could not follow the evolution of pore nor the process of the structural changes of the GUV. Here we used the term "local rupture" to express the rapid leakage of sucrose and determined the rate constant of local rupture, kL. On the basis of the comparison between kp and kL, we concluded that the leakage of calcein from single GUVs occurred as a result of a local rupture in the GUVs and that smaller pores inducing leakage of calcein were not formed before the local rupture. The results of the effect of the surface charge density of lipid membranes and that of salt concentration in buffer on kp clearly show that kp increases with an increase in the extent of electrostatic interactions due to

  17. A planar PDMS micropump using in-contact minimized-leakage check valves

    International Nuclear Information System (INIS)

    Ni, Junhui; Li, Beizhi; Huang, Fengliang; Wang, Bin; Lin, Qiao

    2010-01-01

    We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap–stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e.g. chamber height) and operating parameters (e.g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 µL min −1 and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.

  18. Sourcing methane and carbon dioxide emissions from a small city: Influence of natural gas leakage and combustion.

    Science.gov (United States)

    Chamberlain, Samuel D; Ingraffea, Anthony R; Sparks, Jed P

    2016-11-01

    Natural gas leakage and combustion are major sources of methane (CH 4 ) and carbon dioxide (CO 2 ), respectively; however, our understanding of emissions from cities is limited. We mapped distribution pipeline leakage using a mobile CH 4 detection system, and continuously monitored atmospheric CO 2 and CH 4 concentrations and carbon isotopes (δ 13 C-CO 2 and δ 13 C-CH 4 ) for one-year above Ithaca, New York. Pipeline leakage rates were low (emission source in that wind sector. Our results demonstrate pipeline leakage rates are low in cities with a low extent of leak prone pipe, and natural gas power facilities may be an important source of urban and suburban emissions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Leakage detection algorithm integrating water distribution networks hydraulic model

    CSIR Research Space (South Africa)

    Adedeji, K

    2017-06-01

    Full Text Available Water loss through leaking pipes is inexorable in water distribution networks (WDNs) and has been recognized as a major challenge facing the operation of municipal water services. This is strongly linked with financial costs due to economic loss...

  20. Management of Anastomotic Leakage in a Nationwide Cohort of Colonic Cancer Patients

    DEFF Research Database (Denmark)

    Krarup, Peter-Martin; Jorgensen, Lars N; Harling, Henrik

    2014-01-01

    BACKGROUND: The mortality associated with anastomotic leakage (AL) after colonic cancer surgery is high and management often results in permanent fecal diversion. Preservation of bowel continuity in combination with proximal loop diversion (salvage) may reduce the number of permanent ostomies...... as anastomotic takedown with an end-ostomy or salvage. Thirty-day mortality, long-term mortality, and permanent ostomy rates were analyzed using multivariable logistic and Cox regression analyses. RESULTS: Anastomotic leakage occurred in 593 of 9,333 patients (6.4%), of whom 507 with grade C were included...

  1. Generalized peritonitis requiring re-operation after leakage of omental patch repair of perforated peptic ulcer.

    Science.gov (United States)

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention.

  2. Effect of crack size on gas leakage characteristics in a confined space

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kun Hyuk; Ryou, Hong Sun; Yoon, Kee Bong; Lee, Hy Uk; Bang, Joo Won [Chung-Ang University, Seoul (Korea, Republic of); Li, Longnan; Choi, Jin Wook; Kim, Dae Joong [Sogang University, Seoul (Korea, Republic of)

    2016-07-15

    We numerically investigated the influence of crack size on gas leakage characteristics in a confined space. The real scale model of underground Combined cycle power plant (CCPP) was taken for simulating gas leakage characteristics for different crack sizes such as 10 mm, 15 mm and 20 mm. The commercial code of Fluent (v.16.1) was used for three-dimensional simulation. In particular, a risk region showing such a probability of ignition was newly suggested with the concept of Lower flammable limit (LFL) of methane gas used in the present study to characterize the gas propagation and the damage area in space. From the results, the longitudinal and transverse leakage distances were estimated and analyzed for quantitative evaluation of risk area. The crack size was found to have a great impact on the longitudinal leakage distance, showing an increasing tendency with the crack size. In case of a crack size of 20 mm, the longitudinal leakage distance suddenly increased after 180 s, whereas it remained constant after 2 s in the other cases. This is because a confinement effect, which is caused by circulation flows in the whole space, increased the gas concentration near the gas flow released from the crack. The confinement effect is thus closely associated with the released mass flow rate changing with the crack size. This result would be useful in designing the gas detector system for preventing accidents in the confined space as like CCPP.

  3. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    Science.gov (United States)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  4. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  5. Leakage warning system for flexible underwater pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, E; Bernstein, L

    1985-08-01

    Underwater pipelines for unloading oil tankers, e.g. in 30 km distance from the harbour site, are required to be flexible and require supervision. This is done by implementation of oil sensitive sensors between the inner rubber tube and the following impregnated textile layer. The generated sensor signals, influenced by leak oil, have to be wireless transmitted from 150 meters under water to the supervisory station at the coast. Sensor configurations are described, to derive the point of the leakage from the topologized warning signals.

  6. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  7. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  8. Brine reuse in ion-exchange softening: salt discharge, hardness leakage, and capacity tradeoffs.

    Science.gov (United States)

    Flodman, Hunter R; Dvorak, Bruce I

    2012-06-01

    Ion-exchange water softening results in the discharge of excess sodium chloride to the aquatic environment during the regeneration cycle. In order to reduce sodium chloride use and subsequent discharge from ion-exchange processes, either brine reclaim operations can be implemented or salt application during regeneration can be reduced. Both result in tradeoffs related to loss of bed volumes treated per cycle and increased hardness leakage. An experimentally validated model was used to compare concurrent water softening operations at various salt application quantities with and without the direct reuse of waste brine for treated tap water of typical midwestern water quality. Both approaches were able to reduce salt use and subsequent discharge. Reducing salt use and discharge by lowering the salt application rate during regeneration consequently increased hardness leakage and decreased treatment capacity. Single or two tank brine recycling systems are capable of reducing salt use and discharge without increasing hardness leakage, although treatment capacity is reduced.

  9. The availability of the detection method of internal valve leakage using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Suzuki, Akio

    1989-01-01

    The purpose of this study is to estimate the availability of acoustic method to the internal leakage of the valves at power plants. The acoustic method was applied to the valves at the site, and the background noise was measured for the abnormal plantcondition. From the comparison of the background noise date with the experimental results as to relation between leakage flow and acoust signal, the minimum leakage flow rates that can be detected by the acoust signal was suggested. When the background levels are higher than the acoust signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given. (author)

  10. Germline contamination and leakage in whole genome somatic single nucleotide variant detection.

    Science.gov (United States)

    Sendorek, Dorota H; Caloian, Cristian; Ellrott, Kyle; Bare, J Christopher; Yamaguchi, Takafumi N; Ewing, Adam D; Houlahan, Kathleen E; Norman, Thea C; Margolin, Adam A; Stuart, Joshua M; Boutros, Paul C

    2018-01-31

    The clinical sequencing of cancer genomes to personalize therapy is becoming routine across the world. However, concerns over patient re-identification from these data lead to questions about how tightly access should be controlled. It is not thought to be possible to re-identify patients from somatic variant data. However, somatic variant detection pipelines can mistakenly identify germline variants as somatic ones, a process called "germline leakage". The rate of germline leakage across different somatic variant detection pipelines is not well-understood, and it is uncertain whether or not somatic variant calls should be considered re-identifiable. To fill this gap, we quantified germline leakage across 259 sets of whole-genome somatic single nucleotide variant (SNVs) predictions made by 21 teams as part of the ICGC-TCGA DREAM Somatic Mutation Calling Challenge. The median somatic SNV prediction set contained 4325 somatic SNVs and leaked one germline polymorphism. The level of germline leakage was inversely correlated with somatic SNV prediction accuracy and positively correlated with the amount of infiltrating normal cells. The specific germline variants leaked differed by tumour and algorithm. To aid in quantitation and correction of leakage, we created a tool, called GermlineFilter, for use in public-facing somatic SNV databases. The potential for patient re-identification from leaked germline variants in somatic SNV predictions has led to divergent open data access policies, based on different assessments of the risks. Indeed, a single, well-publicized re-identification event could reshape public perceptions of the values of genomic data sharing. We find that modern somatic SNV prediction pipelines have low germline-leakage rates, which can be further reduced, especially for cloud-sharing, using pre-filtering software.

  11. A comparative study of United States and China exchange rate behavior: A co integration analysis

    Directory of Open Access Journals (Sweden)

    Khuram Shafi

    2015-02-01

    Full Text Available Exchange rates always affect the prices of the imports and export of products and services in which countries are trading with other parts of the world. Therefore, exchange rate calculation is one of the essential issues for making appropriate policies. This research investigates the determinants of trade, i.e. import, export, industrial growth, consumption level and oil prices fluctuation, which bring changes in exchange rate and their influence eventually on balance of payments. Data of defined variables was collected on yearly basis for China and USA for thirty one years. By applying cointegration, it is estimated that there existed a long run relationship in both countries. USA and China had significant and correct signs on the short run dynamic and some of the factors did not. Exchange rate did not granger cause balance of payment and balance of payment did not granger cause exchange rate. In conclusion, we found that determinants of balance of trade could affect the exchange rates, also, these rates had considerable effect (positive or negative on balance of payments. In this twofold study, we found relationship of exchange rate with selected determinants of trade, and also examined their bilateral effect, and then made contrast of both countries.

  12. Substantial underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry.

    Science.gov (United States)

    Rutegård, Martin; Kverneng Hultberg, Daniel; Angenete, Eva; Lydrup, Marie-Louise

    2017-12-01

    The causes and effects of anastomotic leakage after anterior resection are difficult to study in small samples and have thus been evaluated using large population-based national registries. To assess the accuracy of such research, registries should be validated continuously. Patients who underwent anterior resection for rectal cancer during 2007-2013 in 15 different hospitals in three healthcare regions in Sweden were included in the study. Registry data and information from patient records were retrieved. Registered anastomotic leakage within 30 postoperative days was evaluated, using all available registry data and using only the main variable anastomotic insufficiency. With the consensus definition of anastomotic leakage developed by the International Study Group on Rectal Cancer as reference, validity measures were calculated. Some 1507 patients were included in the study. The negative and positive predictive values for registered anastomotic leakage were 96 and 88%, respectively, while the κ-value amounted to 0.76. The false-negative rate was 29%, whereas the false-positive rate reached 1.3% (the vast majority consisting of actual leaks, but occurring after postoperative day 30). Using the main variable anastomotic insufficiency only, the false-negative rate rose to 41%. There is considerable underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry. It is probable that this causes an underestimation of the true effects of leakage on patient outcomes, and further quality control is needed.

  13. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  14. Leakage in the Juelich research reactor

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    On August 17, 1978, a leakage occurred in the DIDO research reactor. Early in the afternoon of this day, the valves of the coolant loop had been checked with the reactor shut off. When the mechanics wanted to oil a tight valve and drilled a hole in the valve cover for this, heavy water started to leak (leakage in the valve membrane). The mechanics left the shielded valve space at once; directly after having a shower, they underwent a radiation protection examination. It was found that none of the mechanics had been exposed to an excessive dose. When other mechanics in protective suits had closed the leak in the valve, a total of 150 liters had leaked into the sump pump at the valve entrance. They were pumped back into the cooling system. About 5 liters of water were evaporated and, via the stack, escaped into the environment. The activity released was about 40 curie; this is less than the permissible amount of 60 curie per week during normal operation. Neither the KFA personnel nor the inhabitants of Juelich and its surroundings were in danger at any moment. Calculations so far yield a maximum radiation exposure below 1mrem at the point of maximum exposure. The cooling circuit could be entered again only one day after the incident. The present shut-off phase of the reactor is not unduly prolonged by this accident. (orig./HP) [de

  15. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  16. Leakage detection system in nuclear reactor container

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The present invention comprises an injection means for adding radioactive materials to coolants in a container cooler, a gamma ray amplitude analyzer connected to coolant pipelines and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to a drain water sump and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to various kinds of pipelines and a means for recording/transferring the data of the result of the measurement, and a data processing means for comparing and analyzing the measured data of each of the gamma ray amplitude analyzers inputted from each of date recording/transferring means. The gamma ray amplitude analysis for each of the pipelines and drain water sump are conducted at an appropriate frequency, and the measured data are compared and analyzed, to improve the detection accuracy for a trace amount of leakage from each of the pressure pipelines and the container cooler coolant pipelines, thereby enabling to specify the pipeline having leakage. Maintenance efficiency is improved, and severe rupture accident in each of pressure pipelines is prevented previously. (N.H.)

  17. Reduced-Order Model for the Geochemical Impacts of Carbon Dioxide, Brine and Trace Metal Leakage into an Unconfined, Oxidizing Carbonate Aquifer, Version 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Bacon, Diana H.

    2013-03-31

    The National Risk Assessment Partnership (NRAP) consists of 5 U.S DOE national laboratories collaborating to develop a framework for predicting the risks associated with carbon sequestration. The approach taken by NRAP is to divide the system into components, including injection target reservoirs, wellbores, natural pathways including faults and fractures, groundwater and the atmosphere. Next, develop a detailed, physics and chemistry-based model of each component. Using the results of the detailed models, develop efficient, simplified models, termed reduced order models (ROM) for each component. Finally, integrate the component ROMs into a system model that calculates risk profiles for the site. This report details the development of the Groundwater Geochemistry ROM for the Edwards Aquifer at PNNL. The Groundwater Geochemistry ROM for the Edwards Aquifer uses a Wellbore Leakage ROM developed at LANL as input. The detailed model, using the STOMP simulator, covers a 5x8 km area of the Edwards Aquifer near San Antonio, Texas. The model includes heterogeneous hydraulic properties, and equilibrium, kinetic and sorption reactions between groundwater, leaked CO2 gas, brine, and the aquifer carbonate and clay minerals. Latin Hypercube sampling was used to generate 1024 samples of input parameters. For each of these input samples, the STOMP simulator was used to predict the flux of CO2 to the atmosphere, and the volume, length and width of the aquifer where pH was less than the MCL standard, and TDS, arsenic, cadmium and lead exceeded MCL standards. In order to decouple the Wellbore Leakage ROM from the Groundwater Geochemistry ROM, the response surface was transformed to replace Wellbore Leakage ROM input parameters with instantaneous and cumulative CO2 and brine leakage rates. The most sensitive parameters proved to be the CO2 and brine leakage rates from the well, with equilibrium coefficients for calcite and dolomite, as well as the number of illite and kaolinite

  18. Modeling of leakage currents in high-k dielectrics

    International Nuclear Information System (INIS)

    Jegert, Gunther Christian

    2012-01-01

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO 2 material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO 2 /TiN capacitor structures were suggested and problem areas that may

  19. Modeling of leakage currents in high-k dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Jegert, Gunther Christian

    2012-03-15

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO{sub 2} material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO{sub 2}/TiN capacitor structures were suggested and problem areas

  20. On leakage and seepage from geological carbon sequestration sites

    Energy Technology Data Exchange (ETDEWEB)

    Oldenburg, C.M.; Unger, A.J.A.; Hepple, R.P.; Jordan, P.D.

    2002-07-18

    Geologic carbon sequestration is one strategy for reducing the rate of increase of global atmospheric carbon dioxide (CO{sub 2} ) concentrations (IEA, 1997; Reichle, 2000). As used here, the term geologic carbon sequestration refers to the direct injection of supercritical CO{sub 2} deep into subsurface target formations. These target formations will typically be either depleted oil and gas reservoirs, or brine-filled permeable formations referred to here as brine formations. Injected CO{sub 2} will tend to be trapped by one or more of the following mechanisms: (1) permeability trapping, for example when buoyant supercritical CO{sub 2} rises until trapped by a confining caprock; (2) solubility trapping, for example when CO{sub 2} dissolves into the aqueous phase in water-saturated formations, or (3) mineralogic trapping, such as occurs when CO{sub 2} reacts to produce stable carbonate minerals. When CO{sub 2} is trapped in the subsurface by any of these mechanisms, it is effectively sequestered away from the atmosphere where it would otherwise act as a greenhouse gas. The purpose of this report is to summarize our work aimed at quantifying potential CO{sub 2} seepage due to leakage from geologic carbon sequestration sites. The approach we take is to present first the relevant properties of CO{sub 2} over the range of conditions from the deep subsurface to the vadose zone (Section 2), and then discuss conceptual models for how leakage might occur (Section 3). The discussion includes consideration of gas reservoir and natural gas storage analogs, along with some simple estimates of seepage based on assumed leakage rates. The conceptual model discussion provides the background for the modeling approach wherein we focus on simulating transport in the vadose zone, the last potential barrier to CO{sub 2} seepage (Section 4). Because of the potentially wide range of possible properties of actual future geologic sequestration sites, we carry out sensitivity analyses by

  1. Application of a leakage model to assess exfiltration from sewers.

    Science.gov (United States)

    Karpf, C; Krebs, P

    2005-01-01

    The exfiltration of wastewater from sewer systems in urban areas causes a deterioration of soil and possibly groundwater quality. Beside the simulation of transport and degradation processes in the unsaturated zone and in the aquifer the analysis of the potential impact requires the estimation of quantity and temporal variation of wastewater exfiltration. Exfiltration can be assessed by the application of a leakage model. The hydrological approach was originally developed to simulate the interactions between the groundwater and surface water, it was adapted to allow for modelling of interactions between groundwater and sewer system. In order to approximate the exfiltration specific model parameters infiltration specific parameters were used as a basis. Scenario analysis of the exfiltration in the City of Dresden from 1997 to 1999 and during the flood event in August 2002 shows the variation and the extent of exfiltration rates.

  2. [Nuclear medicine diagnosis of pulmonary capillary protein leakage].

    Science.gov (United States)

    Creutzig, H; Sturm, J A; Schober, O; Nerlich, M L; Kant, C J

    1984-10-01

    Pulmonary extravascular albumin extravasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation of abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques.

  3. Integrating topography, hydrology and rock structure in weathering rate models of spring watersheds

    NARCIS (Netherlands)

    Pacheco, F.A.L.; Weijden, C.H. van der

    2012-01-01

    Weathering rate models designed for watersheds combine chemical data of discharging waters with morphologic and hydrologic parameters of the catchments. At the spring watershed scale, evaluation of morphologic parameters is subjective due to difficulties in conceiving the catchment geometry.

  4. Efficient video coding integrating MPEG-2 and picture-rate conversion

    NARCIS (Netherlands)

    Bruin, de F.J.; Bruls, W.H.A.; Burazerovic, D.; Haan, de G.

    2002-01-01

    We present an MPEG-2 compliant video codec using picture-rate upconversion during decoding. The upconversion autonomously regenerates major parts of frames without vectorial and residual data. Consequently, the bitrate is greatly reduced.

  5. An integrated pavement data management and feedback system (PAMS) : evaluation of pavement condition rating procedure.

    Science.gov (United States)

    1984-08-01

    This report describes an evaluation of a method for use in the Highway Needs Study pavement condition rating. The methods by which the Department generates and manages pavement condition data in the overall process of providing a network of highways ...

  6. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  7. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  8. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  9. [Greenhouse gas emissions, carbon leakage and net carbon sequestration from afforestation and forest management: A review.

    Science.gov (United States)

    Liu, Bo Jie; Lu, Fei; Wang, Xiao Ke; Liu, Wei Wei

    2017-02-01

    Forests play an important role in climate change mitigation and concentration of CO 2 reduction in the atmosphere. Forest management, especially afforestation and forest protection, could increase carbon stock of forests significantly. Carbon sequestration rate of afforestation ranges from 0.04 to 7.52 t C·hm -2 ·a -1 , while that of forest protection is 0.33-5.20 t C·hm -2 ·a -1 . At the same time, greenhouse gas (GHG) is generated within management boundary due to the production and transportation of the materials consumed in relevant activities of afforestation and forest management. In addition, carbon leakage is also generated outside boundary from activity shifting, market effects and change of environments induced by forest management. In this review, we summarized the definition of emission sources of GHG, monitoring methods, quantity and rate of greenhouse gas emissions within boundary of afforestation and forest management. In addition, types, monitoring methods and quantity of carbon leakage outside boundary of forest management were also analyzed. Based on the reviewed results of carbon sequestration, we introduced greenhouse gas emissions within boundary and carbon leakage, net carbon sequestration as well as the countervailing effects of greenhouse gas emissions and carbon leakage to carbon sequestration. Greenhouse gas emissions within management boundary counteract 0.01%-19.3% of carbon sequestration, and such counteraction could increase to as high as 95% considering carbon leakage. Afforestation and forest management have substantial net carbon sequestration benefits, when only taking direct greenhouse gas emissions within boundary and measurable carbon leakage from activity shifting into consideration. Compared with soil carbon sequestration measures in croplands, afforestation and forest management is more advantageous in net carbon sequestration and has better prospects for application in terms of net mitigation potential. Along with the

  10. Integration

    DEFF Research Database (Denmark)

    Emerek, Ruth

    2004-01-01

    Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration......Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration...

  11. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  12. Development of systems for detection, early warning, and control of pipeline leakage in drinking water distribution: a case study.

    Science.gov (United States)

    Li, Weifeng; Ling, Wencui; Liu, Suoxiang; Zhao, Jing; Liu, Ruiping; Chen, Qiuwen; Qiang, Zhimin; Qu, Jiuhui

    2011-01-01

    Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities. An integrated system for the detection, early warning, and control of pipeline leakage has been developed and successfully used to manage the pipeline networks in selected areas of Beijing. A method based on the geographic information system has been proposed to quickly and automatically optimize the layout of the instruments which detect leaks. Methods are also proposed to estimate the probability of each pipe segment leaking (on the basis of historic leakage data), and to assist in locating the leakage points (based on leakage signals). The district metering area (DMA) strategy is used. Guidelines and a flowchart for establishing a DMA to manage the large-scale looped networks in Beijing are proposed. These different functions have been implemented into a central software system to simplify the day-to-day use of the system. In 2007 the system detected 102 non-obvious leakages (i.e., 14.2% of the total detected in Beijing) in the selected areas, which was estimated to save a total volume of 2,385,000 m3 of water. These results indicate the feasibility, efficiency and wider applicability of this system.

  13. A Spinel-integrated P2-type Layered Composite: High-rate Cathode for Sodium-ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jianming; Yan, Pengfei; Kan, Wang Hay; Wang, Chong M.; Manthiram, Arumugam

    2016-01-14

    Sodium-ion batteries (SIB) are being intensively investigated, owing to the natural abundance and low cost of Na resources. However, the SIBs still suffer from poor rate capability due to the large ionic radius of Na+ ion and the significant kinetic barrier to Na+-ion transport. Here, we present an Fd-3m spinel-integrated P2-type layered composite (P2 + Fd-3m) material as a high-rate cathode for SIBs. The P2 + Fd-3m composite material Na0.50Ni1/6Co1/6Mn2/3O2 shows significantly enhanced discharge capacity, energy density, and rate capability as compared to the pure P2-type counterpart. The composite delivers a high capacity of 85 mA h g-1 when discharging at a very high current density of 1500 mA g-1 (10C rate) between 2.0 and 4.5 V, validating it as a promising cathode candidate for high-power SIBs. The superior performance is ascribed to the improved kinetics in the presence of the integrated-spinel phase, which facilitates fast electron transport to coordinate with the timely Na+-ion insertion/extraction. The findings of this work also shed light on the importance of developing lattice doping, surface coating, and electrolyte additives to further improve the structural and interfacial stability of P2-type cathode materials and fully realize their practical applications in sodium-ion batteries.

  14. Fluid leakage near the percolation threshold

    Science.gov (United States)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  15. Leakages and pressure relation: an experimental research

    Directory of Open Access Journals (Sweden)

    F. De Paola

    2012-11-01

    Full Text Available Leaks in water systems are presently a frequent and increasing event that involves cost increase and poor service, not compliant to quality standards and modern management criteria. The most recent data available in Italy, resumed into the report issued by Control Committee for Water Resources Use (CONVIRI, shows leakages with an average value of 37%. It is therefore important, for maintenance perspective, to investigate occurrence and evolution of water leaks and the analytical link between leaks Qp and network pressure P, for a reliable calibration of water networks quali-quantitative simulation models. The present work reports the first results of an experimental campaign started at Laboratory of Hydraulics of Department of Hydraulics, Geotechnical and Environmental Engineering of University of Naples Federico II in order to analyze the features of Qp(P relation, which are compared with other results issued in literature.

  16. The effect of European integration on exchange rate dependence: the Polish accession to the EU

    NARCIS (Netherlands)

    Thiel, J.H.; van Giersbergen, N.P.A.

    2010-01-01

    This paper investigates the effect of the Polish accession to the European Union (EU) on the dependence between the euro-US dollar and Polish zloty-US dollar exchange rate. The dependence is estimated by means of copulas as suggested by Patton (2006). This approach allows to first specify and

  17. Integrated mechanisms of anticipation and rate-of-change computations in cortical circuits.

    Directory of Open Access Journals (Sweden)

    Gabriel D Puccini

    2007-05-01

    Full Text Available Local neocortical circuits are characterized by stereotypical physiological and structural features that subserve generic computational operations. These basic computations of the cortical microcircuit emerge through the interplay of neuronal connectivity, cellular intrinsic properties, and synaptic plasticity dynamics. How these interacting mechanisms generate specific computational operations in the cortical circuit remains largely unknown. Here, we identify the neurophysiological basis of both the rate of change and anticipation computations on synaptic inputs in a cortical circuit. Through biophysically realistic computer simulations and neuronal recordings, we show that the rate-of-change computation is operated robustly in cortical networks through the combination of two ubiquitous brain mechanisms: short-term synaptic depression and spike-frequency adaptation. We then show how this rate-of-change circuit can be embedded in a convergently connected network to anticipate temporally incoming synaptic inputs, in quantitative agreement with experimental findings on anticipatory responses to moving stimuli in the primary visual cortex. Given the robustness of the mechanism and the widespread nature of the physiological machinery involved, we suggest that rate-of-change computation and temporal anticipation are principal, hard-wired functions of neural information processing in the cortical microcircuit.

  18. Study on the leakage flow through a clearance gap between two stationary walls

    Science.gov (United States)

    Zhao, W.; Billdal, J. T.; Nielsen, T. K.; Brekke, H.

    2012-11-01

    In the present paper, the leakage flow in the clearance gap between stationary walls was studied experimentally, theoretically and numerically by the computational fluid dynamics (CFD) in order to find the relationship between leakage flow, pressure difference and clearance gap. The experimental set-up of the clearance gap between two stationary walls is the simplification of the gap between the guide vane faces and facing plates in Francis turbines. This model was built in the Waterpower laboratory at Norwegian University of Science and Technology (NTNU). The empirical formula for calculating the leakage flow rate between the two stationary walls was derived from the empirical study. The experimental model is simulated by computational fluid dynamics employing the ANSYS CFX commercial software in order to study the flow structure. Both numerical simulation results and empirical formula results are in good agreement with the experimental results. The correction of the empirical formula is verified by experimental data and has been proven to be very useful in terms of quickly predicting the leakage flow rate in the guide vanes for hydraulic turbines.

  19. Evaluation of an integrated adherence program aimed to increase Medicare Part D star rating measures.

    Science.gov (United States)

    Leslie, R Scott; Tirado, Breanne; Patel, Bimal V; Rein, Philip J

    2014-12-01

    The Centers for Medicare Medicaid Services (CMS) Plan Quality and Performance Program, or Star Ratings Program, allows Medicare beneficiaries to compare quality of care among available Medicare Advantage prescription drug (MA-PD) plans and stand-alone prescription drug plans (PDPs). Health plans have increased intervention efforts and applied existing care management infrastructure as an approach to improving member medication adherence and subsequent Part D star rating performance. Independent Care Health Plan (iCare), an MA-PD plan; MedImpact Healthcare Systems, Inc. (MedImpact), a pharmacy benefits manager; and US MED, a mail order pharmacy, partnered to engage and enroll iCare's dual-eligible special needs population in an intervention designed to improve patient medication adherence and health plan performance for 3 Part D patient safety outcome measures: Medication Adherence for Oral Diabetes Medications (ODM), Medication Adherence for Hypertension (HTN), and Medication Adherence for Cholesterol (CHOL). To (a) assess the effectiveness of a coordinated member-directed medication adherence intervention and (b) determine the overall impact of the intervention on adherence rates and CMS Part D star rating adherence measures.  Administrative pharmacy claims and health plan eligibility data from MedImpact's databases were used to identify members using 3 target medication classes. Adherence was estimated by the proportion of days covered (PDC) for all members. Those members considered at high risk for nonadherence were prioritized for care management services. Risk factors were based on members' use of more than 1 target medication class, newly started therapy, and suboptimal adherence (PDC  less than  80%) in the most recent 6-month period. Data files listing member adherence rates and contact information were formatted and loaded monthly into iCare's care management system, which triggered an alert for care coordinators to counsel members on the importance

  20. Electrical leakage phenomenon in heteroepitaxial cubic silicon carbide on silicon

    Science.gov (United States)

    Pradeepkumar, Aiswarya; Zielinski, Marcin; Bosi, Matteo; Verzellesi, Giovanni; Gaskill, D. Kurt; Iacopi, Francesca

    2018-06-01

    Heteroepitaxial 3C-SiC films on silicon substrates are of technological interest as enablers to integrate the excellent electrical, electronic, mechanical, thermal, and epitaxial properties of bulk silicon carbide into well-established silicon technologies. One critical bottleneck of this integration is the establishment of a stable and reliable electronic junction at the heteroepitaxial interface of the n-type SiC with the silicon substrate. We have thus investigated in detail the electrical and transport properties of heteroepitaxial cubic silicon carbide films grown via different methods on low-doped and high-resistivity silicon substrates by using van der Pauw Hall and transfer length measurements as test vehicles. We have found that Si and C intermixing upon or after growth, particularly by the diffusion of carbon into the silicon matrix, creates extensive interstitial carbon traps and hampers the formation of a stable rectifying or insulating junction at the SiC/Si interface. Although a reliable p-n junction may not be realistic in the SiC/Si system, we can achieve, from a point of view of the electrical isolation of in-plane SiC structures, leakage suppression through the substrate by using a high-resistivity silicon substrate coupled with deep recess etching in between the SiC structures.

  1. The Effect of Freezing Stress on Percentage of Electrolytes Leakage and Survival of Flixweed (Descurainia sophia L. Seedlings

    Directory of Open Access Journals (Sweden)

    E Izadi-Darbandi

    2016-10-01

    Full Text Available Introduction Flixweed (Descurainia sophia L. is a medicinal plant from Brassicaceae family which also known as a weed for winter cereals and oil seed rape. Low temperatures are one of the most important abiotic stresses that threat Flixweed growth and productivity. Therefore it is important to recognize the freeze tolerance of Flixweed for successful planting and utilization in cold regions such as Mashhad in Khorasan Razavi Province (Iran’s north. east. Among many laboratory methods which have been developed to estimate and to evaluate plants response or their tolerance to freez ing temperatures, electrolyte leakage (EL test is widely used. This test is based on this principle that damage to the cell membranes results in enhanced leakage of solutes into the apoplastic water, hence recording the amount of leakage after stress treatments provides an estimation of tissue injury. Indeed continuing integration of plasma membrane is one important factor for survival of plants under freezing stress and any disturbance in membrane structure can lead to damage and death. So determination of LT50 point or critical temperature for electrolytes leakage and survival of plant is the most reliable, quantitative and simple methods for evaluating the cold tolerance of plants. The aim of this trial was to determine the LT50 according to the EL and SU% for Flixweed ecotypes. Materials and Methods In order to evaluate freeze tolerance in Flixweed, a factorial experiment based on completely randomized design with three replications was carried out in college of agriculture, Ferdowsi University of Mashhad. Experimental factors included five ecotypes of Flixweed (Eghlid, Sabzewar, Hamedan, Torbat-e-Jam and Neyshabour and 10 freezing temperature levels (0, -2,-4, -6, -8,-10,-12,-14,-16 and -18°C. Flixweed seeds were cultivated in pots in autumn of 2008 and were grown until 5-7 leaf stage under natural weather conditions for acclimation. Then to apply freezing

  2. Improved Adherence Rates and Clinical Outcomes of an Integrated, Closed-Loop, Pharmacist-Led Oral Chemotherapy Management Program.

    Science.gov (United States)

    Muluneh, Benyam; Schneider, Molly; Faso, Aimee; Amerine, Lindsey; Daniels, Rowell; Crisp, Brett; Valgus, John; Savage, Scott

    2018-06-01

    To address the growing use of oral anticancer therapy, an integrated, closed-loop, pharmacist-led oral chemotherapy management program was created within an academic medical center. An integrated, closed-loop, pharmacy-led oral chemotherapy management program was established. From September 2014 until June 2015, demographic information, rates of adherence, patient understanding of treatment, pharmacist interventions, patient and provider satisfaction, and molecular response rates in patients with chronic myeloid leukemia (CML) were collected. After full implementation, 107 patients were enrolled in our oral chemotherapy management program from September 2014 until June 2015. All patients were educated before starting oral chemotherapy, and using pre- and postassessment tests, comprehension of oral chemotherapy treatment increased from 43% to 95%. Patient-reported adherence was 86% and 94.7% for the GI/breast and malignant hematology patient populations, respectively, and these were validated with medication possession ratio, revealing adherence rates of 85% and 93.9% for the GI/breast and malignant hematology patient populations, respectively. A total of 350 encounters with a clinical pharmacist and 318 adverse effects were reported, which led to 235 interventions. This program led to a higher major molecular response rate (83%) in our CML population compared with published clinical trials (average major molecular response rates, 40% and 60% with 1- and 2-year follow-up, respectively). An innovative model was developed and resulted in improved patient knowledge regarding oral chemotherapy, improved adherence rates that exceeded nationally established thresholds, and superior major molecular response outcomes for patients with CML compared with published literature. As a result, this model has produced the gold standard in managing patients receiving oral chemotherapy.

  3. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    Science.gov (United States)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  4. Evidence for CP violation in time-integrated $D^0 \\rightarrow h^-h^+$ decay rates

    CERN Document Server

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Comerma-Montells, A; Constantin, F; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; Elsby, D; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koopman, R; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Mac Raighne, A; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Niess, V; Nikitin, N; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalorav Goicochea, J M; Owen, P; Pal, K; Palacios, J; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pie Valls, B; Pietrzyk, B; Pilař, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rosello, M; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, A C; Smith, N A; Smith, E; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Torr, N; Tournefier, E; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Voss, H; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    A search for time-integrated $CP$ violation in $D^0 \\rightarrow h^-h^+$ ($h=K$, $\\pi$) decays is presented using 0.62~fb$^{-1}$ of data collected by LHCb in 2011. The flavor of the charm meson is determined by the charge of the slow pion in the $D^{*+} \\rightarrow D^0 \\pi^+$ and $D^{*-} \\rightarrow \\overline{D}^0 \\pi^-$ decay chains. The difference in $CP$ asymmetry between $D^0 \\rightarrow K^- K^+$ and $D^0 \\rightarrow \\pi^- \\pi^+$, $\\Delta A_{CP} \\equiv A_{CP}(K^-K^+) \\, - \\, A_{CP}(\\pi^-\\pi^+)$, is measured to be $\\left[ -0.82 \\pm 0.21 (\\mathrm{stat.}) \\pm 0.11 (\\mathrm{syst.}) \\right]\\%$. This differs from the hypothesis of $CP$ conservation by $3.5$ standard deviations.

  5. Online dose rate monitoring: Better information by using the IRMA concept (Integral Radiological Multidetector Arrays)

    International Nuclear Information System (INIS)

    Genrich, V.

    1989-01-01

    A new GM detector system has been developed for online environmental monitoring. The approach is unorthodox, but simple: A) Take a set of radiological probes and feed all their information to an 'intelligent' front-end. B) Elaborate some algorithms, so that the system will give out just one gamma dose rate (running over more than nine decades). C) If necessary, associate some additional sensors, and the system will exhibit better discriminating qualities for the detection of artificial nuclides in the environment. (orig.)

  6. Effect of warming and flow rate conditions of blood warmers on red blood cell integrity.

    Science.gov (United States)

    Poder, T G; Pruneau, D; Dorval, J; Thibault, L; Fisette, J-F; Bédard, S K; Jacques, A; Beauregard, P

    2016-11-01

    Fluid warmers are routinely used to reduce the risk of hypothermia and cardiac complications associated with the infusion of cold blood products. However, warming blood products could generate haemolysis. This study was undertaken to compare the impact of temperature of blood warmers on the per cent haemolysis of packed red blood cells (RBCs) heated at different flow rates as well as non-flow conditions. Infusion warmers used were calibrated at 41·5°C ± 0·5°C and 37·5°C ± 0·5°C. Cold RBC units stored at 4°C in AS-3 (n = 30), aged 30-39 days old, were divided into half units before being allocated under two different scenarios (i.e. infusion pump or syringe). Blood warmers were effective to warm cold RBCs to 37·5°C or 41·5°C when used in conjunction with an infusion pump at flow rate up to 600 ml/h. However, when the warmed blood was held in a syringe for various periods of time, such as may occur in neonatal transfusions, the final temperature was below the expected requirements with measurement as low as 33·1°C. Increasing the flow with an infusion pump increased haemolysis in RBCs from 0·2% to up to 2·1% at a flow rate of 600 ml/h regardless of the warming device used (P < 0·05). No relevant increase of haemolysis was observed using a syringe. The use of a blood warmer adjusted to 41·5°C is probably the best choice for reducing the risk of hypothermia for the patient without generating haemolysis. However, we should be cautious with the use of an infusion pump for RBC transfusion, particularly at high flow rates. © 2016 International Society of Blood Transfusion.

  7. [Integrity].

    Science.gov (United States)

    Gómez Rodríguez, Rafael Ángel

    2014-01-01

    To say that someone possesses integrity is to claim that that person is almost predictable about responses to specific situations, that he or she can prudentially judge and to act correctly. There is a closed interrelationship between integrity and autonomy, and the autonomy rests on the deeper moral claim of all humans to integrity of the person. Integrity has two senses of significance for medical ethic: one sense refers to the integrity of the person in the bodily, psychosocial and intellectual elements; and in the second sense, the integrity is the virtue. Another facet of integrity of the person is la integrity of values we cherish and espouse. The physician must be a person of integrity if the integrity of the patient is to be safeguarded. The autonomy has reduced the violations in the past, but the character and virtues of the physician are the ultimate safeguard of autonomy of patient. A field very important in medicine is the scientific research. It is the character of the investigator that determines the moral quality of research. The problem arises when legitimate self-interests are replaced by selfish, particularly when human subjects are involved. The final safeguard of moral quality of research is the character and conscience of the investigator. Teaching must be relevant in the scientific field, but the most effective way to teach virtue ethics is through the example of the a respected scientist.

  8. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  9. An integral whole circuit of amplifying and discriminating suited to high counting rate

    International Nuclear Information System (INIS)

    Dong Chengfu; Su Hong; Wu Ming; Li Xiaogang; Peng Yu; Qian Yi; Liu Yicai; Xu Sijiu; Ma Xiaoli

    2007-01-01

    A hybrid circuit consists of charge sensitive preamplifier, main amplifier, discriminator and shaping circuit was described. This instrument has characteristics of low power consumption, small volume, high sensitivity, potable and so on, and is convenient for use in field. The output pulse of this instrument may directly consist with CMOS or TTL logic level. This instrument was mainly used for count measurement, for example, for high sensitive 3 He neutron detector, meanwhile also may used for other heavy ion detectors, the highest counting rate can reach 10 6 /s. (authors)

  10. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  11. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  12. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  13. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  14. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  15. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  16. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  17. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  18. Integrated system for recommending fertilization rates in pineapple (Ananas comosus (L. Merr. crop

    Directory of Open Access Journals (Sweden)

    Sergio Salgado García

    2017-10-01

    Full Text Available In recent years much attention has focused on the impacts of agriculture on climate change, due to this stage specialists in plant nutrition and soil fertility have achieved the task of generating adequate fertilization doses for pineapple to reduce effects on environment. A methodology for Integrated System for Recommending Fertilizer Dose (ISRFD was used. As a result, seven Thiessen polygons of the average annual rainfall, where rainfall ranged from 1640 to 2841 mm was correlated. Therefore, three major soil groups were defined and classified as subunit level. Likewise, eight doses of fertilizers were generated as follows: N, P2O5 and K2O, with a fertilizer dose, a map is generated according to the cultivar: 230-138-300 for Creole pineapple in Acrisol Cutanic (Chromic, Ferric; 460-161-480 for Cayenne and MD2 in Acrisol Cutanic (Endoclayic, Ferric; 345-161-450 for Cayenne and MD2, 253-138-450 for Creole in Acrisol Cutanic (Endoclayic, Hyperdystric, Ferric; 391-161-450 for Cayenne and MD2 in Acrisol Umbric Cutanic (Endoclayic, Hyperdystric and Acrisol Umbric Cutanic (Endoclayic, Hyperdystric, Ferric; 207-138-300 for Creole in Acrisol Umbric Cutanic (Endoclayic, Hyperdystric; 253-138-300 for Creole in Acrisol Umbric Cutanic (Endoclayic,Hyperdystric, Ferric; 253-138-360 for Creole in Acrisol Umbric Gleyic (Hyperdystric, Ferric; and 391-161-360 in Cambisol Endogleyic (Clayic, Eutric. These fertilizer doses were supplemented with micronutrients to obtain the expected results.

  19. An Integrated Assessment of Geochemical and Community Structure Determinants of Metal Reduction Rates in Subsurface Sediments

    International Nuclear Information System (INIS)

    Kostka, Joel E.

    2008-01-01

    This project represented a joint effort between Oak Ridge National Laboratory (ORNL), the University of Tennessee (UT), and Florida State University (FSU). ORNL served as the lead in-stitution with Dr. A.V. Palumbo responsible for project coordination, integration, and deliver-ables. In situ uranium bioremediation is focused on biostimulating indigenous microorganisms through a combination of pH neutralization and the addition of large amounts of electron donor. Successful biostimulation of U(VI) reduction has been demonstrated in the field and in the laboratory. However, little data is available on the dynamics of microbial populations capable of U(VI) reduction, and the differences in the microbial community dynamics between proposed electron donors have not been explored. In order to elucidate the potential mechanisms of U(VI) reduction for optimization of bioremediation strategies, structure-function relationships of microbial populations were investigated in microcosms of subsurface materials cocontaminated with radionuclides and nitrate from the Oak Ridge Field Research Center (ORFRC), Oak Ridge, Tennessee.

  20. Integrated experimental and computational studies of deformation of single crystal copper at high strain rates

    Science.gov (United States)

    Rawat, S.; Chandra, S.; Chavan, V. M.; Sharma, S.; Warrier, M.; Chaturvedi, S.; Patel, R. J.

    2014-12-01

    Quasi-static (0.0033 s-1) and dynamic (103 s-1) compression experiments were performed on single crystal copper along ⟨100⟩ and ⟨110⟩ directions and best-fit parameters for the Johnson-Cook (JC) material model, which is an important input to hydrodynamic simulations for shock induced fracture, have been obtained. The deformation of single crystal copper along the ⟨110⟩ direction showed high yield strength, more strain hardening, and less strain rate sensitivity as compared to the ⟨100⟩ direction. Although the JC model at the macro-scale is easy to apply and describes a general response of material deformation, it lacks physical mechanisms that describe the influence of texture and initial orientation on the material response. Hence, a crystal plasticity model based on the theory of thermally activated motion of dislocations was used at the meso-scale, in which the evolution equations permit one to study and quantify the influence of initial orientation on the material response. Hardening parameters of the crystal plasticity model show less strain rate sensitivity along the ⟨110⟩ orientation as compared to the ⟨100⟩ orientation, as also shown by the JC model. Since the deformation process is inherently multiscale in nature, the shape changes observed in the experiments due to loading along ⟨100⟩ and ⟨110⟩ directions are also validated by molecular dynamics simulations at the nano-scale.

  1. Topology and immersion depth of an integral membrane protein by paramagnetic rates from dissolved oxygen.

    Science.gov (United States)

    Al-Abdul-Wahid, M Sameer; Verardi, Raffaello; Veglia, Gianluigi; Prosser, R Scott

    2011-09-01

    In studies of membrane proteins, knowledge of protein topology can provide useful insight into both structure and function. In this work, we present a solution NMR method for the measurement the tilt angle and average immersion depth of alpha helices in membrane proteins, from analysis of the paramagnetic relaxation rate enhancements arising from dissolved oxygen. No modification to the micelle or protein is necessary, and the topology of both transmembrane and amphipathic helices are readily determined. We apply this method to the measure the topology of a monomeric mutant of phospholamban (AFA-PLN), a 52-residue membrane protein containing both an amphipathic and a transmembrane alpha helix. In dodecylphosphocholine micelles, the amphipathic helix of AFA-PLN was found to have a tilt angle of 87° ± 1° and an average immersion depth of 13.2 Å. The transmembrane helix was found to have an average immersion depth of 5.4 Å, indicating residues 41 and 42 are closest to the micelle centre. The resolution of paramagnetic relaxation rate enhancements from dissolved oxygen compares favourably to those from Ni (II), a hydrophilic paramagnetic species.

  2. Topology and immersion depth of an integral membrane protein by paramagnetic rates from dissolved oxygen

    International Nuclear Information System (INIS)

    Al-Abdul-Wahid, M. Sameer; Verardi, Raffaello; Veglia, Gianluigi; Prosser, R. Scott

    2011-01-01

    In studies of membrane proteins, knowledge of protein topology can provide useful insight into both structure and function. In this work, we present a solution NMR method for the measurement the tilt angle and average immersion depth of alpha helices in membrane proteins, from analysis of the paramagnetic relaxation rate enhancements arising from dissolved oxygen. No modification to the micelle or protein is necessary, and the topology of both transmembrane and amphipathic helices are readily determined. We apply this method to the measure the topology of a monomeric mutant of phospholamban (AFA-PLN), a 52-residue membrane protein containing both an amphipathic and a transmembrane alpha helix. In dodecylphosphocholine micelles, the amphipathic helix of AFA-PLN was found to have a tilt angle of 87° ± 1° and an average immersion depth of 13.2 Å. The transmembrane helix was found to have an average immersion depth of 5.4 Å, indicating residues 41 and 42 are closest to the micelle centre. The resolution of paramagnetic relaxation rate enhancements from dissolved oxygen compares favourably to those from Ni (II), a hydrophilic paramagnetic species.

  3. High rate of unplanned pregnancy in the context of integrated family planning and HIV care services in South Africa.

    Science.gov (United States)

    Adeniyi, Oladele Vincent; Ajayi, Anthony Idowu; Moyaki, Mayowa Gabriel; Goon, Daniel Ter; Avramovic, Gordana; Lambert, John

    2018-02-27

    Integration of family planning services into HIV care was implemented in South Africa as a core strategy aimed at reducing unintended pregnancies among childbearing women living with HIV. However, it is unclear whether this strategy has made any significant impact at the population level. This paper describes the prevalence and correlates of self-reported unplanned pregnancy among HIV-infected parturient women attending three large maternity centres in the Eastern Cape, South Africa. We also compare unplanned pregnancy rates between HIV-infected parturient women already in care (who have benefitted from services' integration) and newly diagnosed parturient women (who have not benefitted from services' integration). Drawing from the baseline data of the East London Prospective Cohort Study (ELPCS), data of 594 parturient women living with HIV in the Eastern Cape were included. Chi-square statistics and binary logistics regression were employed to determine the correlates of unplanned pregnancy among the cohort. The prevalence of unplanned pregnancy was 71% (n = 422) with a higher rate among parturient women newly diagnosed during the index pregnancy (87%). Unplanned pregnancy was significantly associated with younger age, single status, HIV diagnosis at booking, high parity and previous abortion. Women who reported unplanned pregnancy were more likely to book late and have lower CD4 counts. After adjusting for confounding variables, having one child and five to seven children (AOR = 2.2; CI = 1.3-3.1), age less than 21 years (AOR = 3.3; CI = 1.1-9.8), late booking after 27 weeks (AOR = 2.7; CI = 1.5-5.0), not married (AOR = 4.3; CI = 2.7-6.8) and HIV diagnosis at booking (AOR = 3.0; CI = 1.6-5.8) were the significant correlates of unplanned pregnancy in the cohort. Unplanned pregnancy remains high overall among parturient women living with HIV in the region, however, with significant reduction among those who were

  4. The Prediction of Exchange Rates with the Use of Auto-Regressive Integrated Moving-Average Models

    Directory of Open Access Journals (Sweden)

    Daniela Spiesová

    2014-10-01

    Full Text Available Currency market is recently the largest world market during the existence of which there have been many theories regarding the prediction of the development of exchange rates based on macroeconomic, microeconomic, statistic and other models. The aim of this paper is to identify the adequate model for the prediction of non-stationary time series of exchange rates and then use this model to predict the trend of the development of European currencies against Euro. The uniqueness of this paper is in the fact that there are many expert studies dealing with the prediction of the currency pairs rates of the American dollar with other currency but there is only a limited number of scientific studies concerned with the long-term prediction of European currencies with the help of the integrated ARMA models even though the development of exchange rates has a crucial impact on all levels of economy and its prediction is an important indicator for individual countries, banks, companies and businessmen as well as for investors. The results of this study confirm that to predict the conditional variance and then to estimate the future values of exchange rates, it is adequate to use the ARIMA (1,1,1 model without constant, or ARIMA [(1,7,1,(1,7] model, where in the long-term, the square root of the conditional variance inclines towards stable value.

  5. Rubber contact mechanics: adhesion, friction and leakage of seals.

    Science.gov (United States)

    Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J

    2017-12-13

    We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.

  6. Exploring relationships among social integration, social isolation, self-rated health, and demographics among Latino day laborers.

    Science.gov (United States)

    Steel, Kenneth C; Fernandez-Esquer, Maria Eugenia; Atkinson, John S; Taylor, Wendell C

    2018-05-01

    Research indicates social integration and social isolation are related to health, and Latino day laborers (LDLs) tend to be socially isolated and, thus, at high risk for adverse health consequences. relationships among social isolation, social integration, self-rated health (SRH), and demographics were examined in a sample of LDLs to contribute to the literature on social networks and health in this and other migrant populations. We analyzed data from 324 LDLs who participated in Proyecto SHILOS (Salud del Hombre Inmigrante Latino), a Houston-based survey of Latino immigrant men's health. Based on the literature, we hypothesized SRH would be (1) positively associated with social integration and (2) negatively associated with social isolation. All proposed measures were first entered into a correlation matrix to identify significant bivariate relationships (p ≤ .05, two-tailed). Associations between variables that were directly correlated with SRH and variables that were, in turn, proximally associated with these variables were then used to develop a structural equation path model of SRH. Individual paths in the model were measured for significance, and goodness of fit was assessed by the model chi-square, the Comparative Fit Index, and the Root Mean Square Error of Approximation. Inconsistent with the first hypothesis, SRH was negatively associated with social integration, as measured by the number of trusted friends. Consistent with the second hypothesis, SRH was negatively associated with social isolation, as measured by needing someone to talk to. More frequent contact with family was also negatively associated with social isolation. Our findings suggest social integration may not always protect and promote health. Therefore, assessing the quality of LDLs' different relationships, not just the quantity, is vital. Future studies should further analyze the effects that social resources have on perceptions of social isolation and health in LDLs and other

  7. Numerical analysis of gas leakage in the piston-cylinder clearance of reciprocating compressors considering compressibility effects

    Science.gov (United States)

    Braga, V. M.; Deschamps, C. J.

    2017-08-01

    Leakage is a major source of inefficiency in low-capacity reciprocating compressors. Not only does it lower the mass flow rate provided by the compressor, reducing its volumetric efficiency, but also gives rise to outflux of energy that decreases the isentropic efficiency. Leakage in the piston-cylinder clearance of reciprocating compressors is driven by the piston motion and pressure difference between the compression chamber and the shell internal environment. In compressors adopted for domestic refrigeration, such a clearance is usually filled by a mixture of refrigerant and lubricating oil. Besides its lubricating function, the oil also acts as sealing element for the piston-cylinder clearance, and hence leakage is expected to be more detrimental to oil-free compressors. This paper presents a model based on the Reynolds equation for compressible fluid flow to predict leakage in oil-free reciprocating compressors. The model is solved throughout the compression cycle so as to assess the effect of the clearance geometry and piston velocity on leakage and compressor efficiency. The results show that compressible fluid flow formulation must be considered for predictions of gas leakage in the cylinder-piston clearance.

  8. Failure analysis of leakage current in plastic encapsulated packages

    International Nuclear Information System (INIS)

    Hu, S.J.; Cheang, F.T.

    1989-12-01

    Plastic encapsulated packages exhibit high leakage current after a few hundred hours steam pressure pot test. The present study investigates two possible sources of leakage current, the mold compound and the lead frame tape used for taping the lead frame fingers. The results of the study indicate that the leakage current is independent of the frame and is not caused by the mold compound. The data further indicates that it is the ionic contents and acrylic-based adhesive layer of the lead frame tapes which cause the leakage current. To eliminate the leakage current, lead frame tape with low ionic contents and non acrylic-based adhesive should be used. (author). 1 fig., 2 tabs, 3 graphs

  9. PERFORMANCE OF LEAKAGE POWER MINIMIZATION TECHNIQUE FOR CMOS VLSI TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    T. Tharaneeswaran

    2012-06-01

    Full Text Available Leakage power of CMOS VLSI Technology is a great concern. To reduce leakage power in CMOS circuits, a Leakage Power Minimiza-tion Technique (LPMT is implemented in this paper. Leakage cur-rents are monitored and compared. The Comparator kicks the charge pump to give body voltage (Vbody. Simulations of these circuits are done using TSMC 0.35µm technology with various operating temper-atures. Current steering Digital-to-Analog Converter (CSDAC is used as test core to validate the idea. The Test core (eg.8-bit CSDAC had power consumption of 347.63 mW. LPMT circuit alone consumes power of 6.3405 mW. This technique results in reduction of leakage power of 8-bit CSDAC by 5.51mW and increases the reliability of test core. Mentor Graphics ELDO and EZ-wave are used for simulations.

  10. Leakage current characteristics of the multiple metal alloy nanodot memory

    International Nuclear Information System (INIS)

    Lee, Gae Hun; Lee, Jung Min; Yang, Hyung Jun; Song, Yun Heub; Bea, Ji Chel; Tanaka, Tetsu

    2010-01-01

    The leakage current characteristics of a multiple metal alloy nanodot device for a nonvolatile random access memory using FePt materials are investigated. Several annealing conditions are evaluated and optimized to suppress the leakage current and to better the memory characterisctics. This work confirmed that the annealing condition of 700 .deg. C in a high vacuum ambience (under 1 x 10 -5 Pa) simultaneously provided good cell characteristics from a high dot density of over 1 x 10 13 /cm 2 and a low leakage current. In addition, a smaller nanodot diameter was found to give a lower leakage current for the multiple nanodot memory. Finally, for the proposed annealing condition, the quadruple FePt multiple nanodot memory with a 2-nm dot diameter provided good leakage current characteristics, showing a threshold voltage shift of under 5% at an initial retention stage of 1000 sec.

  11. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  12. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  13. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    -secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol......In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... against continual memory leakage, under the Bilinear Decisional Diffie-Hellman and $2$-linear assumptions. Our schemes have the following properties: 1. Our DPKE and DIBE schemes tolerate leakage at all times, including during refresh. During refresh the tolerated leakage is a (1/2-o (1),1)-fraction...

  14. RD Collaboration Proposal: Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Chistiansen, J (CERN)

    2013-01-01

    This proposal describes a new RD collaboration to develop the next genrration of hybrid pixel readout chips for use in ATLAS and CMS PHase 2 upgrades. extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. Challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm2 ), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. This collaboration is specifically focused on design of hybrid pixel readout chips, and not on more general chip design or on other aspects of hybrid pixel technology. Participants include 7 institutes on ATLAS and 7 on CMS, plus 2 on both experiments.

  15. Aquaponics: integrating fish feeding rates and ion waste production for strawberry hydroponics

    International Nuclear Information System (INIS)

    Villarroel, M.; Alvarino, J. M. R.; Duran, J. M.

    2011-01-01

    Aquaponics is the science of integrating intensive fish aquaculture with plant production in recirculating water systems. Although ion waste production by f ish cannot satisfy all plant requirements, less is known about the relationship between total feed provided for f ish and the production of milliequivalents (mEq) of different macronutrients for plants, especially for nutrient flow hydroponics used for strawberry production in Spain. That knowledge is essential to consider the amount of macronutrients available in aquaculture systems so that farmers can estimate how much nutrient needs to be supplemented in the waste water from fish, to produce viable plant growth. In the present experiment, tilapia (Oreochromis niloticus L.) were grown in a small-scale recirculating system at two different densities while growth and feed consumption were noted every week for five weeks. At the same time points, water samples were taken to measure pH, EC 2 5, HCO3 - , Cl - , NH + 4 , NO 2 - , NO 3 - , H 2 PO 4 - , SO 4 2 -, Na + , K + , Ca 2 + and Mg 2 + build up. The total increase in mEq of each ion per kg of feed provided to the fish was highest for NO 3 - , followed, in decreasing order, by Ca 2 +, H 2 PO 4 - , K + , Mg 2 + and SO 4 2 -. The total amount of feed required per mEq ranged from 1.61- 13.1 kg for the four most abundant ions (NO 3 - , Ca 2 +, H 2 PO 4 - and K + ) at a density of 2 kg fish m3, suggesting that it would be rather easy to maintain small populations of fish to reduce the cost of hydroponic solution supplementation for strawberries. (Author) 16 refs.

  16. Concrete containment integrity program at EPRI

    International Nuclear Information System (INIS)

    Winkleblack, R.K.; Tang, Y.K.

    1984-01-01

    Many in the nuclear power plant business believe that the catastrophic failure mode for reactor containment structures is unrealistic. One of the goals of the EPRI containment integrity program is to demonstrate that this is true. The objective of the program is to provide the utility industry with an experimental data base and a test-validated analytical method for realistically evaluating the actual over-pressure capability of concrete containment buildings and to predict leakage behavior if higher pressures were to occur. The ultimate goal of this research effort is to characterize the containment leakage mode and rate as a function of internal pressure and time so that the risk can be realistically assessed for hypothetical degraded core accidents. Progress in the first and second phases of the three-phase analytical and testing efforts is discussed

  17. Leakage Performance of the GM + CCL Liner System for the MSW Landfill

    Directory of Open Access Journals (Sweden)

    Fan Jingjing

    2014-01-01

    Full Text Available The contaminants in the landfill leachate press pose a grave threat to environment of the soil and the groundwater beneath the landfill. Despite there being strict requirements in relevant provisions of both domestic and foreign countries for the design of the bottom liner system. Pollution of the soil and the groundwater still took place in a number of landfills because of the leakage. To investigate the leakage rate of the liner systems, the minimum design requirements of the liner systems are summarized according to the provisions of four countries, including China, USA, Germany, and Japan. Comparative analyses using one-dimensional transport model are conducted to study the leakage performance of these liner systems composed of geomembrance (GM and compacted clay layer (CCL meeting the relevant minimum design requirements. Then parametric analyses are conducted to study the effects of the hydraulic head, the thickness of GM, the hydraulic conductivity of CCL, and so forth on the leakage performance of the liner system. It is concluded that the liner system designed according to the minimum design requirements of Germany provide the best antileakage performance, while that of Japan performs the lowest. The key parameters affecting the failure time of the liner system are summarized. Finally, some suggestions for the design of the liner systems are made according to the analyses.

  18. Aquaponics: integrating fish feeding rates and ion waste production for strawberry hydroponics

    Energy Technology Data Exchange (ETDEWEB)

    Villarroel, M; Alvarino, J M. R.; Duran, J M

    2011-07-01

    Aquaponics is the science of integrating intensive fish aquaculture with plant production in recirculating water systems. Although ion waste production by fish cannot satisfy all plant requirements, less is known about the relationship between total feed provided for fish and the production of milliequivalents (mEq) of different macronutrients for plants, especially for nutrient flow hydroponics used for strawberry production in Spain. That knowledge is essential to consider the amount of macronutrients available in aquaculture systems so that farmers can estimate how much nutrient needs to be supplemented in the waste water from fish, to produce viable plant growth. In the present experiment, tilapia (Oreochromis niloticus L.) were grown in a small-scale recirculating system at two different densities while growth and feed consumption were noted every week for five weeks. At the same time points, water samples were taken to measure pH, EC25, HCO3{sup -}, Cl{sup -}, NH{sup +}{sub 4}, NO{sub 2}{sup -}, NO{sub 3}{sup -}, H{sub 2}PO{sub 4}{sup -}, SO{sub 4}{sup 2}-, Na{sup +}, K{sup +}, Ca{sup 2}+ and Mg{sup 2}+ build up. The total increase in mEq of each ion per kg of feed provided to the fish was highest for NO{sub 3}{sup -}, followed, in decreasing order, by Ca{sup 2}+, H{sub 2}PO{sub 4}{sup -}, K{sup +}, Mg{sup 2}+ and SO{sub 4}{sup 2}-. The total amount of feed required per mEq ranged from 1.61 - 13.1 kg for the four most abundant ions (NO{sub 3}{sup -}, Ca{sup 2}+, H{sub 2}PO{sub 4}{sup -} and K{sup +}) at a density of 2 kg fish m{sup -3}, suggesting that it would be rather easy to maintain small populations of fish to reduce the cost of hydroponic solution supplementation for strawberries. (Author) 16 refs.

  19. Influence of Chemical, Mechanical, and Transport Processes on Wellbore Leakage from Geologic CO2 Storage Reservoirs.

    Science.gov (United States)

    Carroll, Susan A; Iyer, Jaisree; Walsh, Stuart D C

    2017-08-15

    Wells are considered to be high-risk pathways for fluid leakage from geologic CO 2 storage reservoirs, because breaches in this engineered system have the potential to connect the reservoir to groundwater resources and the atmosphere. Given these concerns, a few studies have assessed leakage risk by evaluating regulatory records, often self-reported, documenting leakage in gas fields. Leakage is thought to be governed largely by initial well-construction quality and the method of well abandonment. The geologic carbon storage community has raised further concerns because acidic fluids in the CO 2 storage reservoir, alkaline cement meant to isolate the reservoir fluids from the overlying strata, and steel casings in wells are inherently reactive systems. This is of particular concern for storage of CO 2 in depleted oil and gas reservoirs with numerous legacy wells engineered to variable standards. Research suggests that leakage risks are not as great as initially perceived because chemical and mechanical alteration of cement has the capacity to seal damaged zones. Our work centers on defining the coupled chemical and mechanical processes governing flow in damaged zones in wells. We have developed process-based models, constrained by experiments, to better understand and forecast leakage risk. Leakage pathways can be sealed by precipitation of carbonate minerals in the fractures and deformation of the reacted cement. High reactivity of cement hydroxides releases excess calcium that can precipitate as carbonate solids in the fracture network under low brine flow rates. If the flow is fast, then the brine remains undersaturated with respect to the solubility of calcium carbonate minerals, and zones depleted in calcium hydroxides, enriched in calcium carbonate precipitates, and made of amorphous silicates leached of original cement minerals are formed. Under confining pressure, the reacted cement is compressed, which reduces permeability and lowers leakage risks. The

  20. Radiation leakage from linac electron applicator assembly

    International Nuclear Information System (INIS)

    Keys, R.A.; Purdy, J.A.

    1984-01-01

    The electron beam applicator system currently in use on the linear accelerator is constructed of light-weight fiberglass and aluminum. With an applicator in place on the accelerator, the photon collimator jaws are automatically set several centimeters greater than the electron field size projected at the patient's surface. To ensure that no regions of high dose levels exist outside the useful beam, ionization and film measurements were made to quantitate the amount of leakage radiation through the 10 cm x 10 cm and 25 cm x 25 cm applicators. In most regions, the ionization levels at the patient's surface were below 5% of the central axis dose. In one area for the 25 cm applicator, the percentage ionization was 8.5%, which could be reduced by the addition of a small piece of 1/8 inch thick lead. However, ionization levels on the outside surface of the applicator were found to be considerably higher at certain locations for the 25 cm applicator. Results for 6, 9, 12 and 20 MeV electrons are reported here

  1. Integrated load distribution and production planning in series-parallel multi-state systems with failure rate depending on load

    International Nuclear Information System (INIS)

    Nourelfath, Mustapha; Yalaoui, Farouk

    2012-01-01

    A production system containing a set of machines (also called components) arranged according to a series-parallel configuration is addressed. A set of products must be produced in lots on this production system during a specified finite planning horizon. This paper presents a method for integrating load distribution decisions, and tactical production planning considering the costs of capacity change and the costs of unused capacity. The objective is to minimize the sum of capacity change costs, unused capacity costs, setup costs, holding costs, backorder costs, and production costs. The main constraints consist in satisfying the demand for all products over the entire horizon, and in not exceeding available repair resource. The production series-parallel system is modeled as a multi-state system with binary-state components. The proposed model takes into account the dependence of machines' failure rates on their load. Universal generating function technique can be used in the optimization algorithm for evaluating the expected system production rate in each period. We show how the formulated problem can be solved by comparing the results of several multi-product lot-sizing problems with capacity associated costs. The importance of integrating load distribution decisions and production planning is illustrated through numerical examples.

  2. Hospital admission and mortality rates in anorexia nervosa: experience from an integrated medical-psychiatric outpatient treatment.

    Science.gov (United States)

    De Filippo, E; Signorini, A; Bracale, R; Pasanisi, F; Contaldo, F

    2000-12-01

    To evaluate the effectiveness of an integrated medical-psychiatric treatment of major eating disorders. Historical cohort study. Outpatient Unit for Protein Energy Malnutrition of the Department of Clinical and Experimental Medicine, "Federico II" University of Naples, time of study: January 1994 to December 1997 PARTICIPANTS: 147 female patients with restrictive or bulimic anorexia nervosa (mean age 19.8 +/- 13.7, BMI 14.7 +/- 2.1 Kg/m2) consecutively attending the outpatient unit between January 1994 and December 1997. Hospitalization and mortality rates were evaluated up to Jan 1999 with a minimum follow-up of 18 months. There were 23 admissions to the Clinical Nutrition ward for 19 patients (i.e. 12.9%) mostly due to severe protein energy malnutrition, and 2 deaths, only 1 strictly related to anorexia (mortality rate 0.7%). Integrated outpatient medical-psychiatric treatment for major eating disorders is an effective and inexpensive procedure that reduces mortality and admissions due to medical complications in the medium term.

  3. SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

    Energy Technology Data Exchange (ETDEWEB)

    Goggin, L; Kilby, W; Noll, M; Maurer, C [Accuray Inc, Sunnyvale, CA (United States)

    2015-06-15

    Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional

  4. A healthy heart is not a metronome: An integrative review of the heart’s anatomy and heart rate variability

    Directory of Open Access Journals (Sweden)

    Fredric Bruce Shaffer

    2014-09-01

    Full Text Available Heart rate variability (HRV, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF, very-low-frequency (VLF, low-frequency (LF, and high-frequency (HF bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges’ polyvagal theory, Thayer and colleagues’ neurovisceral integration model, Lehrer, Vaschillo, and Vaschillo’s resonance frequency model, and the Institute of HeartMath’s coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  5. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    Science.gov (United States)

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  6. Synchronization of nonidentical chaotic neural networks with leakage delay and mixed time-varying delays

    Directory of Open Access Journals (Sweden)

    Cao Jinde

    2011-01-01

    Full Text Available Abstract In this paper, an integral sliding mode control approach is presented to investigate synchronization of nonidentical chaotic neural networks with discrete and distributed time-varying delays as well as leakage delay. By considering a proper sliding surface and constructing Lyapunov-Krasovskii functional, as well as employing a combination of the free-weighting matrix method, Newton-Leibniz formulation and inequality technique, a sliding mode controller is designed to achieve the asymptotical synchronization of the addressed nonidentical neural networks. Moreover, a sliding mode control law is also synthesized to guarantee the reachability of the specified sliding surface. The provided conditions are expressed in terms of linear matrix inequalities, and are dependent on the discrete and distributed time delays as well as leakage delay. A simulation example is given to verify the theoretical results.

  7. Transcytosis Involvement in Transport System and Endothelial Permeability of Vascular Leakage during Dengue Virus Infection

    Directory of Open Access Journals (Sweden)

    Chanettee Chanthick

    2018-02-01

    Full Text Available The major role of endothelial cells is to maintain homeostasis of vascular permeability and to preserve the integrity of vascular vessels to prevent fluid leakage. Properly functioning endothelial cells promote physiological balance and stability for blood circulation and fluid components. A monolayer of endothelial cells has the ability to regulate paracellular and transcellular pathways for transport proteins, solutes, and fluid. In addition to the paracellular pathway, the transcellular pathway is another route of endothelial permeability that mediates vascular permeability under physiologic conditions. The transcellular pathway was found to be associated with an assortment of disease pathogeneses. The clinical manifestation of severe dengue infection in humans is vascular leakage and hemorrhagic diatheses. This review explores and describes the transcellular pathway, which is an alternate route of vascular permeability during dengue infection that corresponds with the pathologic finding of intact tight junction. This pathway may be the route of albumin transport that causes endothelial dysfunction during dengue virus infection.

  8. An Analytical Model for Prediction of Magnetic Flux Leakage from Surface Defects in Ferromagnetic Tubes

    Directory of Open Access Journals (Sweden)

    Suresh V.

    2016-02-01

    Full Text Available In this paper, an analytical model is proposed to predict magnetic flux leakage (MFL signals from the surface defects in ferromagnetic tubes. The analytical expression consists of elliptic integrals of first kind based on the magnetic dipole model. The radial (Bz component of leakage fields is computed from the cylindrical holes in ferromagnetic tubes. The effectiveness of the model has been studied by analyzing MFL signals as a function of the defect parameters and lift-off. The model predicted results are verified with experimental results and a good agreement is observed between the analytical and the experimental results. This analytical expression could be used for quick prediction of MFL signals and also input data for defect reconstructions in inverse MFL problem.

  9. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  10. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  11. Developement of leakage localization technique by using acoustic signal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Jeon, J. H.; Seo, D. H.; Kim, K. W. [KAIST, Daejeon (Korea, Republic of)

    2010-07-15

    The objective of this research is to develop a leakage monitoring system for pipelines or valves in the secondary water system of a nuclear power plant. The system aims to detect the existence of leakage and to estimate the leak location, especially by utilizing the noise generated from the leak. It is safe, precise real-time alert system compared with the previous monitoring methods and tools such as the visual test and the thermal imaging camera. When there exists leakage in the pipeline or valves of nuclear power plant, the noise due to gas flow is radiated through leak region. That is, the secondary water system with leakage generates different noise from the system without leakage. This motivates us to measure and analyze the noise generated from the secondary water system, so as firstly to detect the existence of leakage, and secondly to estimate the leak location by using the noise source identification technique such as beamforming and acoustic holography. Especially the beamforming method models the signal from the noise source to estimate the location of source. Therefore, it is necessary to model the noise due to leakage which is dependent upon parameters. In the process of leak localization, the reflected wave due to interior walls and the measurement noise should be removed for the precise estimation. Therefore, we attempt to characterize the reflected wave and the measurement noise by modeling the interior sound field, thus to remove them and to localize the leak location with high precision

  12. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  13. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    Science.gov (United States)

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  14. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  15. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  16. Space Vector Modulation Technique to Reduce Leakage Current of a Transformerless Three-Phase Four-Leg Photovoltaic System

    Directory of Open Access Journals (Sweden)

    F. Hasanzad

    2017-06-01

    Full Text Available Photovoltaic systems integrated to the grid have received considerable attention around the world. They can be connected to the electrical grid via galvanic isolation (transformer or without it (transformerless. Despite making galvanic isolation, low frequency transformer increases size, cost and losses. On the other hand, transformerless PV systems increase the leakage current (common-mode current, (CMC through the parasitic capacitors of the PV array. Inverter topology and switching technique are the most important parameters the leakage current depends on. As there is no need to extra hardware for switching scheme modification, it's an economical method for reducing leakage current. This paper evaluates the effect of different space vector modulation techniques on leakage current for a two-level three-phase four-leg inverter used in PV system. It proposes an efficient space vector modulation method which decreases the leakage current to below the quantity specified in VDE-0126-1-1 standard. furthermore, some other characteristics of the space vector modulation schemes that have not been significantly discussed for four-leg inverter, are considered, such as, modulation index, switching actions per period, common-mode voltage (CMV, and total harmonic distortion (THD. An extend software simulation using MATLAB/Simulink is performed to verify the effectiveness of the modulation technique.

  17. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  18. Designing adaptive integral sliding mode control for heart rate regulation during cycle-ergometer exercise using bio-feedback.

    Science.gov (United States)

    Argha, Ahmadreza; Su, Steven W; Nguyen, Hung; Celler, Branko G

    2015-01-01

    This paper considers our developed control system which aims to regulate the exercising subjects' heart rate (HR) to a predefined profile. The controller would be an adaptive integral sliding mode controller. Here it is assumed that the controller commands are interpreted as biofeedback auditory commands. These commands can be heard and implemented by the exercising subject as a part of the control-loop. However, transmitting a feedback signal while the pedals are not in the appropriate position to efficiently exert force may lead to a cognitive disengagement of the user from the feedback controller. To address this problem this paper will employ a different form of control system regarding as "actuator-based event-driven control system". This paper will claim that the developed event-driven controller makes it possible to effectively regulate HR to a predetermined HR profile.

  19. Extracting rephase-invariant CP and CPT violating parameters from asymmetries of time-ordered integrated rates of correlated decays of entangled mesons

    International Nuclear Information System (INIS)

    Huang, Zhijie; Shi, Yu.

    2012-01-01

    We present a general model-independent formalism of measuring CP and CPT violating parameters through time-ordered integrated rates of correlated decays of C=±1 entangled states of neutral pseudoscalar mesons. We give the general formulae of CP and CPT violating parameters in terms of four measurable asymmetries defined for the time-ordered integrated rates, applicable to all kinds of decay product. Two special cases which are often realized in experiments are discussed specifically. (orig.)

  20. Development and validation of a new global well-being outcomes rating scale for integrative medicine research

    Directory of Open Access Journals (Sweden)

    Bell Iris R

    2004-01-01

    Full Text Available Abstract Background Researchers are finding limitations of currently available disease-focused questionnaire tools for outcome studies in complementary and alternative medicine/integrative medicine (CAM/IM. Methods Three substudies investigated the new one-item visual analogue Arizona Integrative Outcomes Scale (AIOS, which assesses self-rated global sense of spiritual, social, mental, emotional, and physical well-being over the past 24 hours and the past month. The first study tested the scale's ability to discriminate unhealthy individuals (n = 50 from healthy individuals (n = 50 in a rehabilitation outpatient clinic sample. The second study examined the concurrent validity of the AIOS by comparing ratings of global well-being to degree of psychological distress as measured by the Brief Symptom Inventory (BSI in undergraduate college students (N = 458. The third study evaluated the relationships between the AIOS and positively- and negatively-valenced tools (Positive and Negative Affect Scale and the Positive States of Mind Scale in a different sample of undergraduate students (N = 62. Results Substudy (i Rehabilitation patients scored significantly lower than the healthy controls on both forms of the AIOS and a current global health rating. The AIOS 24-hours correlated moderately and significantly with global health (patients r = 0.50; controls r = 0.45. AIOS 1-month correlations with global health were stronger within the controls (patients r = 0.36; controls r = 0.50. Controls (r = 0.64 had a higher correlation between the AIOS 24-hour and 1-month forms than did the patients (r = 0.33, which is consistent with the presumptive improvement in the patients' condition over the previous 30 days in rehabilitation. Substudy (ii In undergraduate students, AIOS scores were inversely related to distress ratings, as measured by the global severity index on the BSI (rAIOS24h = -0.42, rAIOS1month = -0.40. Substudy (iii AIOS scores were significantly

  1. N13 - based reactor coolant pressure boundary leakage system

    International Nuclear Information System (INIS)

    Dissing, E.; Marbaeck, L.; Sandell, S.; Svansson, L.

    1980-05-01

    A system for the monitoring of leakage of coolant from the reactor coolant pressure boundary and auxiliary systems to the reactor containment, based on the detection of the N13 content in the atmosphere, has been tested. N13 is produced from the oxyegen of the reactor water via the recoil photon nuclear process H1 + 016 + He4. The generation of N13 is therefore independent of fuel element leakage and of the corrosion product content in the water. In the US AEC regulatory guide 1.45 has a leakage increase of 4 liter/ min been suggested as the response limit. The experiments carried out in Ringhals indicate, that with the accomplishment of minor improvements in the installation, a 4 liter/min leakage to the containment will give rise to a signal with a random error range of +- 0.25 liter/min, 99.7 % confidence level. (author)

  2. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  3. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  4. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  5. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  6. Leakage Testing for Different Adhesive Systems and Composites to ...

    African Journals Online (AJOL)

    2015-11-16

    Nov 16, 2015 ... resin composite, the fifth group – two‑stage SE adhesive applied and cavities filled with ... KEYWORDS: Adhesives, composite, evaluation, leakage ... the glass ionomers. ... systems are realized in one or two clinical step(s).[5].

  7. Containment long-term operational integrity

    International Nuclear Information System (INIS)

    Sammataro, R.F.

    1990-01-01

    Periodic integrated leak rate tests are required to assure that containments continue to meet allowable leakage limits. Although overall performance has been quite good to date, several major containment aging and degradation mechanisms have been identified. Two pilot plant life extension (PLEX) studies serve as models for extending the operational integrity of present containments for light-water cooled nuclear power plants in the United States. One study is for a Boiling-Water Reactor (BWR) and the second is for a Pressurized-Water Reactor (PWR). Research and testing programs for determining the ultimate pressure capacity and failure mechanisms for containments under severe loading conditions and studies for extending the life of current plants beyond the present 40-year licensed lifetime are under way. This paper presents an overview of containment designs in the United States. Also presented are a discussion of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) and regulatory authority requirements for the design, construction, inservice inspection, leakage testing and repair of steel and concrete containments. Findings for containments from the pilot PLEX studies and continuing containment integrity research and testing programs are discussed. The ASME Code and regulatory requirements together with recommendations from the PLEX studies and containment integrity research and testing provide a basis for continued containment long-term operational integrity. (orig./GL)

  8. Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery.

    Science.gov (United States)

    Varenika, Vanja; Dickinson, Peter; Bringas, John; LeCouteur, Richard; Higgins, Robert; Park, John; Fiandaca, Massimo; Berger, Mitchel; Sampson, John; Bankiewicz, Krystof

    2008-11-01

    The authors have shown that convection-enhanced delivery (CED) of gadoteridol-loaded liposomes (GDLs) into different regions of normal monkey brain results in predictable, widespread distribution of this tracking agent as detected by real-time MR imaging. They also have found that this tracking technique allows monitoring of the distribution of similar nanosized agents such as therapeutic liposomes and viral vectors. A limitation of this procedure is the unexpected leakage of liposomes out of targeted parenchyma or malignancies into sulci and ventricles. The aim of the present study was to evaluate the efficacy of CED after the onset of these types of leakage. The authors documented this phenomenon in a study of 5 nonhuman primates and 7 canines, comprising 54 CED infusion sessions. Approximately 20% of these infusions resulted in leakage into cerebral ventricles or sulci. All of the infusions and leakage events were monitored with real-time MR imaging. The authors created volume-distributed versus volume-infused graphs for each infusion session. These graphs revealed the rate of distribution of GDL over the course of each infusion and allowed the authors to evaluate the progress of CED before and after leakage. The distribution of therapeutics within the target structure ceased to increase or resulted in significant attenuation after the onset of leakage. An analysis of the cases in this study revealed that leakage undermines the efficacy of CED. These findings reiterate the importance of real-time MR imaging visualization during CED to ensure an accurate, robust distribution of therapeutic agents.

  9. Highly conducting leakage-free electrolyte for SrCoOx-based non-volatile memory device

    Science.gov (United States)

    Katase, Takayoshi; Suzuki, Yuki; Ohta, Hiromichi

    2017-10-01

    The electrochemical switching of SrCoOx-based non-volatile memory with a thin-film-transistor structure was examined by using liquid-leakage-free electrolytes with different conductivities (σ) as the gate insulator. We first examined leakage-free water, which is incorporated in the amorphous (a-) 12CaO.7Al2O3 film with a nanoporous structure (Calcium Aluminate with Nanopore), but the electrochemical oxidation/reduction of the SrCoOx layer required the application of a high gate voltage (Vg) up to 20 V for a very long current-flowing-time (t) ˜40 min, primarily due to the low σ [2.0 × 10-8 S cm-1 at room temperature (RT)] of leakage-free water. We then controlled the σ of the leakage-free electrolyte, infiltrated in the a-NaxTaO3 film with a nanopillar array structure, from 8.0 × 10-8 S cm-1 to 2.5 × 10-6 S cm-1 at RT by changing the x = 0.01-1.0. As the result, the t, required for the metallization of the SrCoOx layer under small Vg = -3 V, becomes two orders of magnitude shorter with increase of the σ of the a-NaxTaO3 leakage-free electrolyte. These results indicate that the ion migration in the leakage-free electrolyte is the rate-determining step for the electrochemical switching, compared to the other electrochemical process, and the high σ of the leakage-free electrolyte is the key factor for the development of the non-volatile SrCoOx-based electro-magnetic phase switching device.

  10. Detecting the leakage source of a reservoir using isotopes.

    Science.gov (United States)

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. LMFBR technology. FFTF cover-gas leakage calculation

    International Nuclear Information System (INIS)

    Deboi, H.

    1974-01-01

    The FFTF LMFBR is intended to have a near zero release of radioactive gases during normal reactor operation with 1% failed fuel. This report presents calculations which provide an approximation of these cover gas leakages. Data from ongoing static and dynamic seal leak tests at AI are utilized. Leakage through both elastomeric and metallic seals in all sub-assemblies and penetrations comprising the reactor cover gas containment during reactor operation system are included

  12. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  13. Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements

    Directory of Open Access Journals (Sweden)

    Borodinecs Anatolijs

    2016-01-01

    Full Text Available In addition to transmission heat loses the infiltration of outdoor air can cause significant heat losses. The external building envelope should be airtight in order to prevent uncontrolled cold air infiltration. The article analysis modern building materials and structures influence on airtightness. The practical measurements of renovated buildings’ airtightness are presented and compared to non-renovated buildings. In addition paper presents data on airtightness measurements of whole multi apartment building and single apartment in analyzed building taking inco accout properties of building materials. The airtightness of single apartment was evaluated with support pressure in neighbor apartments. The results show that the airtightness measurements of multi apartment building can be evaluated by measuring single apartment on last floor with support pressure in neighbor apartments. The practical measurement of renovated buildings had shown the air leakage rate q50 of typical Latvian construction after renovation is between 2.5 and 2.9 m3/(m2·h. Since the building envelope has to minimize the heat loses (transmission and infiltration and ventilation system either mechanical or natural has to provide necessary air exchange, the building envelope airtightness shouldn’t be dependent on type of ventilation systems.

  14. Detecting fluid leakage of a reservoir dam based on streaming self-potential measurements

    Science.gov (United States)

    Song, Seo Young; Kim, Bitnarae; Nam, Myung Jin; Lim, Sung Keun

    2015-04-01

    Between many reservoir dams for agriculture in suburban area of South Korea, water leakage has been reported several times. The dam under consideration in this study, which is located in Gyeong-buk, in the south-east of the Korean Peninsula, was reported to have a large leakage at the right foot of downstream side of the reservoir dam. For the detection of the leakage, not only geological survey but also geophysical explorations have been made for precision safety diagnosis, since the leakage can lead to dam failure. Geophysical exploration includes both electrical-resistivity and self-potential surveys, while geological surveys water permeability test, standard penetration test, and sampling for undisturbed sample during the course of the drilling investigation. The geophysical explorations were made not only along the top of dam but also transverse the heel of dam. The leakage of water installations can change the known-heterogeneous structure of the dam body but also cause streaming spontaneous (self) potential (SP) anomaly, which can be detected by electrical resistivity and SP measurements, respectively. For the interpretation of streaming SP, we used trial-and-error method by comparing synthetic SP data with field SP data for model update. For the computation, we first invert the resistivity data to obtain the distorted resistivity structure of the dam levee then make three-dimensional electrical-resistivity modeling for the streaming potential distribution of the dam levee. Our simulation algorithm of streaming SP distribution based on the integrated finite difference scheme computes two-dimensional (2D) SP distribution based on the distribution of calculated flow velocities of fluid for a given permeability structure together with physical properties. This permeability is repeatedly updated based on error between synthetic and field SP data, until the synthetic data match the field data. Through this trial-and-error-based SP interpretation, we locate the

  15. Management and prevention of chylous leakage after laparoscopic lymphadenectomy.

    Science.gov (United States)

    Han, L-P; Zhang, H-M; Abha, H-D; Liu, T; Zhang, X-P

    2014-01-01

    To investigate the development and management of chylous leakage after laparoscopic retroperitoneal lymphadenectomy. From July 2006 to September 2013, 13 cases of chylous leakage after the laparoscopic lymphadenectomy (6 cases of renal cell carcinoma, 4 cases of gastric cancer, 2 cases of ovarian cancer, 1 case of endometrial cancer) were studied to analyze the occurrence, development and management of chylous leakage. In 3 cases (2 cases of renal cell carcinoma, 1 case of gastric cancer) massive amount of milky fluid drainage was be seen after the first two days post operation. Dietary intervention, TPN (total parenteral nutrition), somatostatin therapy, maintenance of continuous drainage helped to successfully manage the condition in about 1 month duration. In the remaining 10 cases, chylous leakage appeared after restoring normal diet. Managed with changes in diet and maintenance of unobstructed drainage, they were cured in about 2 weeks after treatment. There was significant reduction in drain output, ultrasonography did not reveal presence of free fluid collection in abdomen, and the patients were in good condition without signs and symptoms of infections. Chylous leakage is a rare complication of retroperitoneal lymph node dissection. Surgeons should be familiar with laparoscopic techniques, relevant anatomy and be aware of the fact that the effect of CO2 pressure and use of ultrasonic knife to occlude the lymphatic vessel can transiently block the leakage making the surgeon overlook them. Routine placement of indwelling drainage tube, immediate diagnosis, dietary modification, TPN, somatostatin and drainage are the modalities of conservative management.

  16. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  17. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  18. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  19. Zero-Point Energy Leakage in Quantum Thermal Bath Molecular Dynamics Simulations.

    Science.gov (United States)

    Brieuc, Fabien; Bronstein, Yael; Dammak, Hichem; Depondt, Philippe; Finocchi, Fabio; Hayoun, Marc

    2016-12-13

    The quantum thermal bath (QTB) has been presented as an alternative to path-integral-based methods to introduce nuclear quantum effects in molecular dynamics simulations. The method has proved to be efficient, yielding accurate results for various systems. However, the QTB method is prone to zero-point energy leakage (ZPEL) in highly anharmonic systems. This is a well-known problem in methods based on classical trajectories where part of the energy of the high-frequency modes is transferred to the low-frequency modes leading to a wrong energy distribution. In some cases, the ZPEL can have dramatic consequences on the properties of the system. Thus, we investigate the ZPEL by testing the QTB method on selected systems with increasing complexity in order to study the conditions and the parameters that influence the leakage. We also analyze the consequences of the ZPEL on the structural and vibrational properties of the system. We find that the leakage is particularly dependent on the damping coefficient and that increasing its value can reduce and, in some cases, completely remove the ZPEL. When using sufficiently high values for the damping coefficient, the expected energy distribution among the vibrational modes is ensured. In this case, the QTB method gives very encouraging results. In particular, the structural properties are well-reproduced. The dynamical properties should be regarded with caution although valuable information can still be extracted from the vibrational spectrum, even for large values of the damping term.

  20. Internal Leakage Fault Detection and Tolerant Control of Single-Rod Hydraulic Actuators

    Directory of Open Access Journals (Sweden)

    Jianyong Yao

    2014-01-01

    Full Text Available The integration of internal leakage fault detection and tolerant control for single-rod hydraulic actuators is present in this paper. Fault detection is a potential technique to provide efficient condition monitoring and/or preventive maintenance, and fault tolerant control is a critical method to improve the safety and reliability of hydraulic servo systems. Based on quadratic Lyapunov functions, a performance-oriented fault detection method is proposed, which has a simple structure and is prone to implement in practice. The main feature is that, when a prescribed performance index is satisfied (even a slight fault has occurred, there is no fault alarmed; otherwise (i.e., a severe fault has occurred, the fault is detected and then a fault tolerant controller is activated. The proposed tolerant controller, which is based on the parameter adaptive methodology, is also prone to realize, and the learning mechanism is simple since only the internal leakage is considered in parameter adaptation and thus the persistent exciting (PE condition is easily satisfied. After the activation of the fault tolerant controller, the control performance is gradually recovered. Simulation results on a hydraulic servo system with both abrupt and incipient internal leakage fault demonstrate the effectiveness of the proposed fault detection and tolerant control method.

  1. A direct-conversion WLAN transceiver baseband with DC offset compensation and carrier leakage reduction

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Fang; Yan Jun; Ma Heping; Shi Yin [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Foster, Dai Fa, E-mail: fyuan@sci-inc.com.c [Department of Electrical and Computer Engineering, Auburn University, Auburn, AL 36849-5201 (United States)

    2010-10-15

    A dual-band direct-conversion WLAN transceiver baseband compliant with the IEEE 802.11a/b/g standards is described. Several critical techniques for receiver DC offset compensation and transmitter carrier leakage rejection calibration are presented that enable the direct-conversion architecture to meet all WLAN specifications. The receiver baseband VGA provides 62 dB gain range with steps of 2 dB and a DC offset cancellation circuit is introduced to remove the offset from layout and self-mixing. The calibration loop achieves constant high-pass pole when gain changes; and a fast response time by programming the pole to 1 MHz during preamble and to 30 kHz during receiving data. The transmitter baseband employs an auto-calibration loop with on-chip AD and DA to suppress the carrier leakage, and AD can be powered down after calibration to save power consumption. The chip consumes 17.52 mA for RX baseband VGA and DCOC, and 8.3 mA for TX carrier leakage calibration (5.88 mA after calibration) from 2.85 V supply. Implemented in a 0.35 {mu}m SiGe technology, they occupy 0.68 mm{sup 2} and 0.18 mm{sup 2} die size respectively. (semiconductor integrated circuits)

  2. Modeling the effect of seal leakage on spontaneous heating in a longwall gob area

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.C.; Yuan, L. [National Inst. for Occupational Safety and Health, Pittsburgh, PA (United States). Office of Mine Safety and Health Research

    2010-07-01

    Three coal mines in the United States with a history of spontaneous combustion use a bleederless ventilation system as a control measure. In a bleederless system, one of the headgate entries is used as the tailgate entry of the succeeding panel and is isolated from the gob of the active panel by gob seals that are installed in the headgate entry as the face advances. An active longwall panel using a Y-type bleederless ventilation system was simulated in this study. As longwall mining progresses, some seals are known to leak. Computational fluid dynamics (CFD) simulations were performed to study the effect of seal leakage on spontaneous heating of coal in the longwall gob area. The simulation results showed that under typical bleederless ventilation conditions, the maximum temperature in the gob increased with an increase in leakage rate. The maximum temperature occurred at the headgate side corner at the back end of the panel. When only 1 or 2 seals were leaking, the maximum temperature occurred around the seal. The results demonstrate that complex interactions between pressure differential and gob permeability at different locations in the gob cause ventilation pathways. The interactions depend greatly on gob permeability and seal leakage rates. 8 refs., 1 tab., 14 figs.

  3. Leakage Currents in Low-Voltage PME and BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2015-01-01

    Introduction of BME capacitors to high-reliability electronics as a replacement for PME capacitors requires better understanding of changes in performance and reliability of MLCCs to set justified screening and qualification requirements. In this work, absorption and leakage currents in various lots of commercial and military grade X7R MLCCs rated to 100V and less have been measured to reveal difference in behavior of PME and BME capacitors in a wide range of voltages and temperatures. Degradation of leakage currents and failures in virgin capacitors and capacitors with introduced cracks has been studied at different voltages and temperatures during step stress highly accelerated life testing. Mechanisms of charge absorption, conduction and degradation have been discussed and a failure model in capacitors with defects suggested.

  4. Determination of limits for smallest detectable and largest subcritical leakage cracks in piping systems

    International Nuclear Information System (INIS)

    Bieselt, R.; Wolf, M.

    1995-01-01

    Nuclear power plant piping systems - those still in their original as-built condition as well as upgraded designs - are subject to safety analysis. In order to limit the consequences of postulated piping failures, the basic safety concept incorporating rupture preclusion criteria is applied to specific high-energy piping systems. Leak-before-break analyses are also conducted within the framework of this concept. These analyses serve to determine the potential consequences of jet and reaction forces due to maximum subcritical leakage cracks while also establishing the minimum crack sizes that would be reliably detectable by the leakage rates resulting from these cracks. The boundary conditions for these analyses are not clearly defined. Using various examples as a basis, this paper presents and discusses how the leak-before-break concept can be applied. (orig.)

  5. Power crowbar system coupled by a current transformer with very low leakage inductance

    International Nuclear Information System (INIS)

    Kitagawa, S.; Hirano, K.I.

    1976-01-01

    A reliable, efficient power crowbar system has been developed for fast pinch experiments. In order to reduce the effective impedance of series capacitor system, a current transformer with extremely low leakage inductance has been designed and used. Primary and secondary windings of the transformer are alternately arranged as closely as possible. As a result, the leakage inductance is reduced to 2 nH. It is demonstrated that a current of 390 kA, the rise time of which is 4.5 μsec, is sustained for 100 μsec. Much larger system is being built, which maintains a current of 1 MA over 1 msec. The life of crowbar gap switches is prolonged by the aid of a mechanically-driven metal-to-metal contact switch. Another crowbar switch system with a high coulomb rating is under consideration, in which a gap switch is used together with a saturable reactor and a current transformer

  6. CFD study of leakage flows in shroud cavities of a compressor impeller

    Science.gov (United States)

    Soldatova, K.

    2017-08-01

    The flow character in a gap between shroud disc of an impeller and a stator surface (shroud cavity) influences disc friction loss, labyrinth seal loss (parasitic losses) and thrust force. Flow calculations inside the shroud cavity of a model of centrifugal compressor stage and its labyrinth seal in a range of flow rates and axial width and radial gap are presented. The results are presented in terms of non-dimensional coefficients of flow, disc friction and seal leakage losses coefficients and pressure coefficient. The distributions meridional and tangential flow velocities correspond to the continuity and equilibrium equations - flow radial circulation exists in wide cavity and is absent in narrow cavities. The radial pressure distributions as measured and calculated are not fully comparable. The possible reason is that CFD-calculated leakage coefficient is less than calculated by A.Stodola formula. The influence of a cavity width on the losses and the thrust force requires a balanced design.

  7. Development of monitoring system using acoustic emission for detection of helium gas leakage for primary cooling system and flow-induced vibration for heat transfer tube of heat exchangers for the High Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    Tachibana, Yukio; Kunitomi, Kazuhiko; Furusawa, Takayuki; Shinozaki, Masayuki; Satoh, Yoshiyuki; Yanagibashi, Minoru

    1998-10-01

    The High Temperature Engineering Test Reactor (HTTR) uses helium gas for its primary coolant, whose leakage inside reactor containment vessel is considered in design of the HTTR. It is necessary to detect leakage of helium gas at an early stage so that total amount of the leakage should be as small as possible. On the other hand, heat transfer tubes of heat exchangers of the HTTR are designed not to vibrate at normal operation, but the flow-induced vibration is to be monitored to provide against an emergency. Thus monitoring system of acoustic emission for detection of primary coolant leakage and vibration of heat transfer tubes was developed and applied to the HTTR. Before the application to the HTTR, leakage detection test was performed using 1/4 scaled model of outer tube of primary concentric hot gas duct. Result of the test covers detectable minimum leakage rate and effect of difference in gas, pressure, shape of leakage path and distance from the leaking point. Detectable minimum leakage rate was about 5 Ncc/sec. The monitoring system is promising in leakage detection, though countermeasure to noise is to be needed after the HTTR starts operating. (author)

  8. Estimation of probability density functions of damage parameter for valve leakage detection in reciprocating pump used in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Kyeom; Kim, Tae Yun; Kim, Hyun Su; Chai, Jang Bom; Lee, Jin Woo [Div. of Mechanical Engineering, Ajou University, Suwon (Korea, Republic of)

    2016-10-15

    This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

  9. Endoscopic vacuum-assisted closure of anastomotic leakage following anterior resection of the rectum: a new method.

    Science.gov (United States)

    Weidenhagen, Rolf; Gruetzner, Klaus Uwe; Wiecken, Timm; Spelsberg, Fritz; Jauch, Karl-Walter

    2008-08-01

    Conservative treatment of anastomotic leakage after anterior resection of the rectum seems to be possible in patients who have no occurrence of generalized peritonitis. This report describes a new method of endoscopic management of large anastomotic leakage in these patients. The main feature of this new method is the endoscopically assisted placement of an open-cell sponge connected to a vacuum device into the abscess cavity via an introducer device. The sponge system is changed every 48-72 h. Twenty-nine patients with an anastomotic leakage after anterior resection were treated with the endoscopic vacuum therapy. The total duration of endovac therapy was 34.4 +/- 19.4 days. The total number of endoscopic sessions per patient was 11.4 +/- 6.3. In 21 of the 29 patients, a protecting stoma was created at the primary operation. Four patients were treated successfully without the need of a secondary stoma. Definitive healing was achieved in 28 of the 29 patients. Endoscopic vacuum-assisted closure is a new efficacious modality for treating anastomotic leakage following anterior resection due to an effective control of the septic focus. Further studies will show if it is possible to reduce the high mortality rate of patients with anastomotic leakage through the avoidance of surgical reinterventions while at the same time preserving the sphincter function.

  10. Estimation of probability density functions of damage parameter for valve leakage detection in reciprocating pump used in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Jong Kyeom; Kim, Tae Yun; Kim, Hyun Su; Chai, Jang Bom; Lee, Jin Woo

    2016-01-01

    This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage

  11. Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Jong Kyeom Lee

    2016-10-01

    Full Text Available This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

  12. Sensitivity Analysis of Core Damage from Reactor Coolant Pump Seal Leakage during Extended Loss of All AC Power

    Energy Technology Data Exchange (ETDEWEB)

    Park, Da Hee; Kim, Min Gi; Lee, Kyung Jin; Hwang, Su hyun; Lee, Byung Chul [FNC Technology Co. Ltd., Yongin (Korea, Republic of); Yoon, Duk Joo; Lee, Seung Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    In this study, in order to comprehend the Fukushima accident, the sensitivity analysis was performed to analyze the behavior of Reactor Coolant System (RCS) during ELAP using the RELAP5/MOD3.3 code. The Fukushima accident was caused by tsunami resulted in Station Black Out (SBO) followed by the reactor core melt-down and release of radioactive materials. After the accident, the equipment and strategies for the Extended Loss of All AC Power (ELAP) were recommended strongly. In this analysis, sensitivity studies for the RCP seal failure of the OPR1000 type NPP were performed by using RELAP5/MOD3.3 code. Six cases with different leakage rate of RCP seal were studied for ELAP with operator action or not. The main findings are summarized as follows: (1) Without the operator action, the core uncovery time is determined by the leakage rate of RCP seal. When the leakage rate per RCP seal are 5 gpm, 50 gpm, and 300 gpm respectively, the core uncovery time are 1.62 hr, 1.58 hr, and 1.29 hr respectively. Namely, If the leakage rate of RCP seal was much bigger, the uncover time of core would be shorter. (2) In case that the cooling by SG secondary side was performed using the TDAFP and SG ADV, the core uncovery time was significantly extended.

  13. A Study of the Mechanical Behavior of OFHC Copper in Tension at Various Strain Rates and Heating Rates Using the Two-Dimensional Integrated Speckle Measuring System

    National Research Council Canada - National Science Library

    Durant, Brian

    2000-01-01

    .... A modified dog bone specimen was heated using resistive heating techniques. The effects of high temperature, medium strain rates, and high heating rates on the stress-strain results were observed...

  14. Basin-Scale Leakage Risks from Geologic Carbon Sequestration: Impact on Carbon Capture and Storage Energy Market Competitiveness

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Catherine; Fitts, Jeffrey; Wilson, Elizabeth; Pollak, Melisa; Bielicki, Jeffrey; Bhatt, Vatsal

    2013-03-13

    This three-year project, performed by Princeton University in partnership with the University of Minnesota and Brookhaven National Laboratory, examined geologic carbon sequestration in regard to CO{sub 2} leakage and potential subsurface liabilities. The research resulted in basin-scale analyses of CO{sub 2} and brine leakage in light of uncertainties in the characteristics of leakage processes, and generated frameworks to monetize the risks of leakage interference with competing subsurface resources. The geographic focus was the Michigan sedimentary basin, for which a 3D topographical model was constructed to represent the hydrostratigraphy. Specifically for Ottawa County, a statistical analysis of the hydraulic properties of underlying sedimentary formations was conducted. For plausible scenarios of injection into the Mt. Simon sandstone, leakage rates were estimated and fluxes into shallow drinking-water aquifers were found to be less than natural analogs of CO{sub 2} fluxes. We developed the Leakage Impact Valuation (LIV) model in which we identified stakeholders and estimated costs associated with leakage events. It was found that costs could be incurred even in the absence of legal action or other subsurface interference because there are substantial costs of finding and fixing the leak and from injection interruption. We developed a model framework called RISCS, which can be used to predict monetized risk of interference with subsurface resources by combining basin-scale leakage predictions with the LIV method. The project has also developed a cost calculator called the Economic and Policy Drivers Module (EPDM), which comprehensively calculates the costs of carbon sequestration and leakage, and can be used to examine major drivers for subsurface leakage liabilities in relation to specific injection scenarios and leakage events. Finally, we examined the competiveness of CCS in the energy market. This analysis, though qualitative, shows that financial

  15. Thoracic air-leakage syndrome in allogeneic stem cell transplant recipients as a late complication of chronic graft-versus-host disease: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Wook; Kim, Song Soo; Jo, Daeg Yeon; Yun, Hwan Jung; Lee, Hyo Jin; Kim, Jin Hwan [Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2016-08-15

    Air-leakage syndrome associated with graft-versus-host disease (GVHD) is a rare complication, but it is also reported as an independent predictor of a worse survival rate after stem cell transplantation. We report two cases of air-leakage syndrome associated with GVHD after allogeneic stem cell transplantation in acute leukemia patients who presented with spontaneous pneumomediastinum and subcutaneous emphysema, and finally death due to respiratory failure seven to eight months later.

  16. 'Integration'

    DEFF Research Database (Denmark)

    Olwig, Karen Fog

    2011-01-01

    , while the countries have adopted disparate policies and ideologies, differences in the actual treatment and attitudes towards immigrants and refugees in everyday life are less clear, due to parallel integration programmes based on strong similarities in the welfare systems and in cultural notions...... of equality in the three societies. Finally, it shows that family relations play a central role in immigrants’ and refugees’ establishment of a new life in the receiving societies, even though the welfare society takes on many of the social and economic functions of the family....

  17. A calculation technique to improve continuous monitoring of containment integrity

    International Nuclear Information System (INIS)

    Dick, J.E.

    1990-01-01

    The containment envelope of nuclear plants is a passive and extremely effective safety feature. World experience indicates, however, that inadvertent breaches of envelope integrity can go undetected for substantial time periods. Consequently, continuous monitoring of integrity is being closely examined by many containment designers and operators. The most promising approach is to use sensors and systems that automatically measure changes in the mass of air in containment, time integrate any known air mass flow rates across containment boundaries, and perform a mass balance to obtain the air mass leaked. As fluctuations in such measurements are typically too large to enable leakage to be calculated to the desired precision, filtering and statistical techniques must be used to filter out random and time-dependent fluctuations. Current approaches cannot easily deal with nonrandom or systematic fluctuations in the measurements, including pressure changes within the containment. As a result, sampling periods must be kept short, or data measured during periods of varying containment pressure must be discarded. The technique described allows for much longer sampling periods under conditions of fluctuating containment pressure and eliminates the invalidation of data when the containment pressure fluctuation is nonrandom. It should therefore yield a much more precise value for the containment leakage characteristic. It also promises to be able to distinguish the presence of systematic errors unrelated to systematic pressure changes and to establish whether the containment leakage characteristic is laminar or turbulent

  18. Reduced-Order Model for Leakage Through an Open Wellbore from the Reservoir due to Carbon Dioxide Injection

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Lehua [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Oldenburg, Curtis M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-07-26

    Potential CO2 leakage through existing open wellbores is one of the most significant hazards that need to be addressed in geologic carbon sequestration (GCS) projects. In the framework of the National Risk Assessment Partnership (NRAP) which requires fast computations for uncertainty analysis, rigorous simulation of the coupled wellbore-reservoir system is not practical. We have developed a 7,200-point look-up table reduced-order model (ROM) for estimating the potential leakage rate up open wellbores in response to CO2 injection nearby. The ROM is based on coupled simulations using T2Well/ECO2H which was run repeatedly for representative conditions relevant to NRAP to create a look-up table response-surface ROM. The ROM applies to a wellbore that fully penetrates a 20-m thick reservoir that is used for CO2 storage. The radially symmetric reservoir is assumed to have initially uniform pressure, temperature, gas saturation, and brine salinity, and it is assumed these conditions are held constant at the far-field boundary (100 m away from the wellbore). In such a system, the leakage can quickly reach quasi-steady state. The ROM table can be used to estimate both the free-phase CO2 and brine leakage rates through an open well as a function of wellbore and reservoir conditions. Results show that injection-induced pressure and reservoir gas saturation play important roles in controlling leakage. Caution must be used in the application of this ROM because well leakage is formally transient and the ROM lookup table was populated using quasi-steady simulation output after 1000 time steps which may correspond to different physical times for the various parameter combinations of the coupled wellbore-reservoir system.

  19. Direct lymphangiography as treatment option of lymphatic leakage: Indications, outcomes and role in patient's management

    Energy Technology Data Exchange (ETDEWEB)

    Gruber-Rouh, Tatjana, E-mail: tgruberrouh@googlemail.com [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N.N. [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Department of Radiology, Faculty of Medicine, Alexandria University, Alexandria (Egypt); Lehnert, Thomas; Harth, Marc; Thalhammer, Axel; Beeres, Martin [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Tsaur, Igor [Department of Urology, Johann Wolfgang Goethe University Frankfurt, Frankfurt am Main (Germany); Hammersting, Renate; Wichmann, Julian L.; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-12-15

    Background: To evaluate the effectiveness of lymphography as a minimally invasive treatment option of lymphatic leakage in terms of local control and to investigate which parameters influence the success rate. Method: This retrospective study protocol was approved by the ethic committee. Patient history, imaging data, therapeutic options and follow-up were recorded and retrospectively analyzed. Between June 1998 and February 2013, 71 patients (m:w = 42:29, mean age, 52.4; range 42–75 years) with lymphatic leakage in form of lymphatic fistulas (n = 37), lymphocele (n = 11), chylothorax (n = 13) and chylous ascites (n = 10) underwent lymphography. Sixty-four patients (90.1%) underwent successful lymphography while lymphography failed in 7 cases. Therapeutic success was evaluated and correlated to the volume of lymphatic leakage and to the volume of the applied iodized oil. Result: Signs of leakage or contrast extravasation were directly detected in 64 patients. Of 64 patients, 45 patients (70.3%) were treated and cured after lymphography. Based on the lymphography findings, 19 patients (29.7%) underwent surgical intervention with a completely occlusion of lymphatic leakage. The lymphatic leak could be completely occluded in 96.8% of patients when the lymphatic drainage volume was less than 200 mL/day (n = 33). Even when lymphatic drainage was higher than 200 mL/day (n = 31), therapeutic lymphography was still successful in 58.1% of the patients. Conclusion: Lymphography is an effective, minimally invasive method in the detection and treatment of lymphatic leakage. The volume of lymphatic drainage per day is a significant predictor of the therapeutic success rate.

  20. Redo coloanal anastomosis for anastomotic leakage after low anterior resection for rectal cancer: an analysis of 59 cases.

    Science.gov (United States)

    Westerduin, E; Borstlap, W A A; Musters, G D; Westerterp, M; van Geloven, A A W; Tanis, P J; Wolthuis, A M; Bemelman, W A; D'Hoore, A

    2018-01-01

    The construction of a new coloanal anastomosis (CAA) following anastomotic leakage after low anterior resection (LAR) is challenging. The available literature on this topic is scarce. The aim of this two-centre study was to determine the clinical success and morbidity after redo CAA. This retrospective cohort study included all patients with anastomotic leakage after LAR for rectal cancer who underwent a redo CAA between 2010 and 2014 in two tertiary referral centres. Short- and long-term morbidity were analysed, including both anastomotic leakage and permanent stoma rates on completion of follow-up. A total of 59 patients were included, of whom 45 (76%) were men, with a mean age of 59 years (SD ± 9.4). The median interval between index and redo surgery was 14 months [interquartile range (IQR) 8-27]. The median duration of follow-up was 27 months (IQR 17-36). The most frequent complication was anastomotic leakage of the redo CAA occurring in 24 patients (41%), resulting in a median of three reinterventions (IQR 2-4) per patient. At the end of follow-up, bowel continuity was restored in 39/59 (66%) patients. Fourteen (24%) patients received a definitive colostomy and six (10%) still had a diverting ileostomy. In a multivariable model, leakage of the redo CAA was the only risk factor for permanent stoma (OR 0.022; 95% CI 0.004-0.122). Redo CAA is a viable option in selected patients with persisting leakage after LAR for rectal cancer who want their bowel continuity restored. However, patients should be fully informed about the relatively high morbidity and reintervention rates. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  1. Direct lymphangiography as treatment option of lymphatic leakage: Indications, outcomes and role in patient's management

    International Nuclear Information System (INIS)

    Gruber-Rouh, Tatjana; Naguib, Nagy N.N.; Lehnert, Thomas; Harth, Marc; Thalhammer, Axel; Beeres, Martin; Tsaur, Igor; Hammersting, Renate; Wichmann, Julian L.; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    Background: To evaluate the effectiveness of lymphography as a minimally invasive treatment option of lymphatic leakage in terms of local control and to investigate which parameters influence the success rate. Method: This retrospective study protocol was approved by the ethic committee. Patient history, imaging data, therapeutic options and follow-up were recorded and retrospectively analyzed. Between June 1998 and February 2013, 71 patients (m:w = 42:29, mean age, 52.4; range 42–75 years) with lymphatic leakage in form of lymphatic fistulas (n = 37), lymphocele (n = 11), chylothorax (n = 13) and chylous ascites (n = 10) underwent lymphography. Sixty-four patients (90.1%) underwent successful lymphography while lymphography failed in 7 cases. Therapeutic success was evaluated and correlated to the volume of lymphatic leakage and to the volume of the applied iodized oil. Result: Signs of leakage or contrast extravasation were directly detected in 64 patients. Of 64 patients, 45 patients (70.3%) were treated and cured after lymphography. Based on the lymphography findings, 19 patients (29.7%) underwent surgical intervention with a completely occlusion of lymphatic leakage. The lymphatic leak could be completely occluded in 96.8% of patients when the lymphatic drainage volume was less than 200 mL/day (n = 33). Even when lymphatic drainage was higher than 200 mL/day (n = 31), therapeutic lymphography was still successful in 58.1% of the patients. Conclusion: Lymphography is an effective, minimally invasive method in the detection and treatment of lymphatic leakage. The volume of lymphatic drainage per day is a significant predictor of the therapeutic success rate

  2. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    Science.gov (United States)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier

  3. Leakage evaluation in the PCV (Primary Containment Vessel) using chemical and radiochemical data

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nagasawa, Katsumi

    1998-01-01

    Keeping the reliability of nuclear power plant operation, the primary coolant leakage in the PCV is strictly restricted by the Technical Specifications. It is very important to detect an indication of leakage and estimate the source of leakage to provide countermeasures. Usually the indication of leakage will be detected by increase of drain flow in the PCV sump. There are some possibilities of leakage sources in the PCV, such as reactor water, main steam, condensate, feedwater and closed cooling water. The leakage source contain different chemical and radiochemical species. This means that the leakage source can be presumed and detected by using chemical information from the PCV atmosphere and sump water. To detect the leakage indication and the source quickly and exactly, the PCV Leakage Detection Expert System has been developed. This paper describes how to evaluate the leakage indication and source in the PCV by using chemical and radiochemical data. (author)

  4. Hydrogeochemical impact of CO{sub 2} leakage from geological sequestration on shallow potable aquifers

    Energy Technology Data Exchange (ETDEWEB)

    Cahill, A.G.

    2013-09-15

    Over the past 10 years scientists have worked in earnest to understand the potential effects of leakage in order that an informed decision on CCGS implementation can be made. This research can be broadly described as aiming to answer two key questions; how deleterious is leakage of CCGS to groundwater resources? and can it be detected geochemically? Some common hydrochemical development is apparent from the literature however many aspects of hydrogeological and hydrogeochemical impact of leakage into shallow aquifers used in water supply remain unclear. In this Ph.D. study an integrated approach was employed in order to answer the two key questions regarding leakage of CO{sub 2} into shallow aquifers. Consequently a combination of laboratory and field investigations were conducted supported by numerical geochemical modeling in order to identify, constrain and quantify processes controlling groundwater chemistry evolution. The output is 4 journal articles and 3 technical reports. In paper I and technical report I simple batch reactors were employed coupled to comprehensive sediment characterization to determine the likely effects of CO{sub 2} on water chemistry in a range of shallow aquifers. Results showed aquifers can be broadly divided into three types; carbonate dominated, silicate dominated and mixed. Each aquifer type showed distinct water chemistry evolution thus inherent risks vary. These studies also highlighted the complexity of risk assessment and detection caused by the range of formation types potentially overlying storage reservoirs. Investigations described in Papers II, III and technical report II increase applicability to real leakage by observing in situ effects including groundwater flow. A silicate dominated shallow aquifer in Vroegum, western Denmark forms the focus of study upon which a series of investigations were conducted. The main field study involved injection of 1600 kg of gas phase CO{sub 2} into the shallow Vroegum aquifer over 72 days

  5. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  6. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  7. New Method for Leakage Detection by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Attari

    2018-03-01

    Full Text Available Nowadays water loss has been turned into a global concern and on the other hand the demand for water is increasing. This problem has made the demand management and consumption pattern reform necessary. One of the most important methods for managing water consumption is to decrease the water loss. In this study by using neural networks, a new method is presented to specify the location and quantity of leakages in water distribution networks.  In this method, by producing the training data and applying it to neural network, the network is able to determine approximate location and quantity of nodal leakage with receiving the nodal pressure. Production of training data is carried out by applying assumed leakage to specific nodes in the network and calculating the new nodal pressures. The results show that by minimum use of hydraulic data taken from pressures, not only this method can determine the location of nodal leakages, but also it can specify the amount of leakage on each node with reasonable accuracy.

  8. Gas-path leakage seal for a gas turbine

    Science.gov (United States)

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  9. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  10. Maximizing Storage Rate and Capacity and Insuring the Environmental Integrity of Carbon Dioxide Sequestration in Geological Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    L.A. Davis; A.L. Graham; H.W. Parker; J.R. Abbott; M.S. Ingber; A.A. Mammoli; L.A. Mondy; Quanxin Guo; Ahmed Abou-Sayed

    2005-12-07

    Maximizing Storage Rate and Capacity and Insuring the Environmental Integrity of Carbon Dioxide Sequestration in Geological Formations The U.S. and other countries may enter into an agreement that will require a significant reduction in CO2 emissions in the medium to long term. In order to achieve such goals without drastic reductions in fossil fuel usage, CO2 must be removed from the atmosphere and be stored in acceptable reservoirs. The research outlined in this proposal deals with developing a methodology to determine the suitability of a particular geologic formation for the long-term storage of CO2 and technologies for the economical transfer and storage of CO2 in these formations. A novel well-logging technique using nuclear-magnetic resonance (NMR) will be developed to characterize the geologic formation including the integrity and quality of the reservoir seal (cap rock). Well-logging using NMR does not require coring, and hence, can be performed much more quickly and efficiently. The key element in the economical transfer and storage of the CO2 is hydraulic fracturing the formation to achieve greater lateral spreads and higher throughputs of CO2. Transport, compression, and drilling represent the main costs in CO2 sequestration. The combination of well-logging and hydraulic fracturing has the potential of minimizing these costs. It is possible through hydraulic fracturing to reduce the number of injection wells by an order of magnitude. Many issues will be addressed as part of the proposed research to maximize the storage rate and capacity and insure the environmental integrity of CO2 sequestration in geological formations. First, correlations between formation properties and NMR relaxation times will be firmly established. A detailed experimental program will be conducted to determine these correlations. Second, improved hydraulic fracturing models will be developed which are suitable for CO2 sequestration as opposed to enhanced oil recovery (EOR

  11. Theoretical study and control optimization of an integrated pest management predator-prey model with power growth rate.

    Science.gov (United States)

    Sun, Kaibiao; Zhang, Tonghua; Tian, Yuan

    2016-09-01

    This work presents a pest control predator-prey model, where rate of change in prey density follows a scaling law with exponent less than one and the control is by an integrated management strategy. The aim is to investigate the change in system dynamics and determine a pest control level with minimum control price. First, the dynamics of the proposed model without control is investigated by taking the exponent as an index parameter. And then, to determine the frequency of spraying chemical pesticide and yield releases of the predator, the existence of the order-1 periodic orbit of the control system is discussed in cases. Furthermore, to ensure a certain robustness of the adopted control, i.e., for an inaccurately detected species density or a deviation, the control system could be stabilized at the order-1 periodic orbit, the stability of the order-1 periodic orbit is verified by an stability criterion for a general semi-continuous dynamical system. In addition, to minimize the total cost input in pest control, an optimization problem is formulated and the optimum pest control level is obtained. At last, the numerical simulations with a specific model are carried out to complement the theoretical results. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Integrated Supply Chain Cooperative Inventory Model with Payment Period Being Dependent on Purchasing Price under Defective Rate Condition

    Directory of Open Access Journals (Sweden)

    Ming-Feng Yang

    2015-01-01

    Full Text Available In most commercial transactions, the buyer and vendor may usually agree to postpone payment deadline. During such delayed period, the buyer is entitled to keep the products without having to pay the sale price. However, the vendor usually hopes to receive full payment as soon as possible, especially when the transaction involves valuable items; yet, the buyer would offer a higher purchasing price in exchange of a longer postponement. Therefore, we assumed such permissible delayed period is dependent on the purchasing price. As for the manufacturing side, defective products are inevitable from time to time, and not all of those defective products can be repaired. Hence, we would like to add defective production and repair rate to our proposed model and discuss how these factors may affect profits. In addition, holding cost, ordering cost, and transportation cost will also be considered as we develop the integrated inventory model with price-dependent payment period under the possible condition of defective products. We would like to find the maximum of the joint expected total profit for our model and come up with a suitable inventory policy accordingly. In the end, we have also provided a numerical example to clearly illustrate possible solutions.

  13. Financial Risk Factor Analysis for Facility Gas Leakages of H2 and NG

    Directory of Open Access Journals (Sweden)

    In-Bok Lee

    2016-09-01

    Full Text Available Fuel cells may be the key to a more environmentally-friendly future because they emit low carbon dioxide per unit of energy supplied. However, little work has investigated the potential financial risks pertaining to fuel cell systems. Often used in the analysis of the safety of systems involving flammable or hazardous materials, risk factor analysis has recently been used to analyze the potential financial losses that may occur from industrial hazards. Therefore, this work undertakes a financial risk factor analysis to determine the costs of leakages of hydrogen and natural gas, which are used in fuel cell systems. Total leakage was calculated from an analysis of several leakage rates and modes. The impact of applying appropriate detection and prevention systems was also investigated. The findings were then used to analyze the consequences for various sections of the system and to calculate the overall cost based on facility outage or damage, and the cost of taking safety precautions. This provides a basis for comparison among proposed potential reactionary measures.

  14. Geochemical Implications of CO2 Leakage Associated with Geologic Storage: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Omar R.; Qafoku, Nikolla; Cantrell, Kirk J.; Brown, Christopher F.

    2012-07-09

    Leakage from deep storage reservoirs is a major risk factor associated with geologic sequestration of carbon dioxide (CO2). Different scientific theories exist concerning the potential implications of such leakage for near-surface environments. The authors of this report reviewed the current literature on how CO2 leakage (from storage reservoirs) would likely impact the geochemistry of near surface environments such as potable water aquifers and the vadose zone. Experimental and modeling studies highlighted the potential for both beneficial (e.g., CO2 re sequestration or contaminant immobilization) and deleterious (e.g., contaminant mobilization) consequences of CO2 intrusion in these systems. Current knowledge gaps, including the role of CO2-induced changes in redox conditions, the influence of CO2 influx rate, gas composition, organic matter content and microorganisms are discussed in terms of their potential influence on pertinent geochemical processes and the potential for beneficial or deleterious outcomes. Geochemical modeling was used to systematically highlight why closing these knowledge gaps are pivotal. A framework for studying and assessing consequences associated with each factor is also presented in Section 5.6.

  15. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent

    2012-01-01

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t’am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  16. Eddy covariance observations of surface leakage during shallow subsurface CO2 releases

    Science.gov (United States)

    Lewicki, Jennifer L.; Hilley, George E.; Fischer, Marc L.; Pan, Lehua; Oldenburg, Curtis M.; Dobeck, Laura; Spangler, Lee

    2009-06-01

    We tested the ability of eddy covariance (EC) to detect, locate, and quantify surface CO2 flux leakage signals within a background ecosystem. For 10 days starting on 9 July 2007, and for 7 days starting on 3 August 2007, 0.1 (Release 1) and 0.3 (Release 2) t CO2 d-1, respectively, were released from a horizontal well ˜100 m in length and ˜2.5 m in depth located in an agricultural field in Bozeman, Montana. An EC station measured net CO2 flux (Fc) from 8 June 2006 to 4 September 2006 (mean and standard deviation = -12.4 and 28.1 g m-2 d-1, respectively) and from 28 May 2007 to 4 September 2007 (mean and standard deviation = -12.0 and 28.1 g m-2 d-1, respectively). The Release 2 leakage signal was visible in the Fc time series, whereas the Release 1 signal was difficult to detect within variability of ecosystem fluxes. To improve detection ability, we calculated residual fluxes (Fcr) by subtracting fluxes corresponding to a model for net ecosystem exchange from Fc. Fcr had reduced variability and lacked the negative bias seen in corresponding Fc distributions. Plotting the upper 90th percentile Fcr versus time enhanced the Release 2 leakage signal. However, values measured during Release 1 fell within the variability assumed to be related to unmodeled natural processes. Fcr measurements and corresponding footprint functions were inverted using a least squares approach to infer the spatial distribution of surface CO2 fluxes during Release 2. When combined with flux source area evaluation, inversion results roughly located the CO2 leak, while resolution was insufficient to quantify leakage rate.

  17. Risk factors, treatment and impact on outcomes of bile leakage after hemihepatectomy.

    Science.gov (United States)

    Zheng, Si-Ming; Li, Hong; Li, Gen-Cong; Yu, Dan-Song; Ying, Dong-Jian; Zhang, Bin; Lu, Cai-De; Zhou, Xin-Hua

    2017-07-01

    Risk factors for bile leakage after hemihepatectomy are unknown. A prospectively maintained database review identified patients undergoing hemihepatectomy between 1 January 2009 and 30 September 2014. Patients were divided into B/C and non-B/C bile leakage groups. Risk factors for bile leakage were predicted and assessments of their impact on patients were made. Bile leakage occurred in 91 of the 297 patients (30.6%); 64 cases were classified as grade B bile leakage (21.5%) and three cases as grade C bile leakage (1.0%). Multivariate analysis confirmed that elevated preoperative alanine transaminase (ALT), positive bile culture during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery were risk factors for B/C grade bile leakage (P bile leakage (P bile leakage (P bile leakage group were higher than those in the non-B/C bile leakage group (P bile leakage group also required prolonged hospitalization (P 0.05). Patient with elevated preoperative ALT, positive bile cultures during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery are more likely to complicate bile leakage. We should use biliary drainage such as preoperative PTBD, ENBD or intraoperative Kehr's T-tube drainage to reduce and treat bile leakage in patients with high risk of bile leakage. © 2015 Royal Australasian College of Surgeons.

  18. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  19. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  20. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.