WorldWideScience

Sample records for integrated goggle head

  1. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  2. Three-dimensional biomimetic head model as a platform for thermal testing of protective goggles for prevention of eye injuries.

    Science.gov (United States)

    Friedman, Rinat; Haimy, Ayelet; Gefen, Amit; Epstein, Yoram

    2018-04-22

    The rate of eye injury is steadily rising during military conflicts of the century, with thermal burns being the most common type of injury to the eyes. The present study focuses on assessing the heat resistance properties of military protective goggles using three-dimensional (3D) finite element head modeling fitted with the tested protective gear. A computational thermal impact was applied onto a 3D biomimetic human head model fitted with two goggle models - sports (Type 1) and square (Type 2). The resultant temperature of the eye tissues and the thermal injury thresholds were calculated by using the modeling, hence allowing to determine the protective efficacy of the goggles objectively, in a standardized, quantitative and cost-effective manner. Both types of goggles had a dramatic protective effect on the eyes. The specific goggle geometry had no notable effect on the level of protection to the inner tissues against the thermal insult. At the skin level goggles reduced temperatures by ~64% under the impact zone, with only a mild difference (10 °C) between the goggles. Little limitations on the shape and geometry of goggles were observed and any structure of goggles can provide an adequate protection against a thermal insult (per se) to inner cranial tissues, assuming the lenses are wide and thick enough to block direct skin contact of the heat insult. It was shown that our 3D biomimetic human head model provides a practical and cost-effective tool for determining the performance level of goggles with different attributed (i.e., shapes and thermal properties). Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. A goggle navigation system for cancer resection surgery

    Science.gov (United States)

    Xu, Junbin; Shao, Pengfei; Yue, Ting; Zhang, Shiwu; Ding, Houzhu; Wang, Jinkun; Xu, Ronald

    2014-02-01

    We describe a portable fluorescence goggle navigation system for cancer margin assessment during oncologic surgeries. The system consists of a computer, a head mount display (HMD) device, a near infrared (NIR) CCD camera, a miniature CMOS camera, and a 780 nm laser diode excitation light source. The fluorescence and the background images of the surgical scene are acquired by the CCD camera and the CMOS camera respectively, co-registered, and displayed on the HMD device in real-time. The spatial resolution and the co-registration deviation of the goggle navigation system are evaluated quantitatively. The technical feasibility of the proposed goggle system is tested in an ex vivo tumor model. Our experiments demonstrate the feasibility of using a goggle navigation system for intraoperative margin detection and surgical guidance.

  4. Do swimming goggles limit microbial contamination of contact lenses?

    Science.gov (United States)

    Wu, Yvonne T; Tran, Jess; Truong, Michelle; Harmis, Najat; Zhu, Hua; Stapleton, Fiona

    2011-04-01

    Wearing goggles over contact lenses while swimming is often recommended by eye care professionals. Limited data are available to assess this recommendation. The purpose of this study was to examine whether wearing goggles while swimming limits bacterial colonization on contact lenses and whether the type of lens worn affects contamination rates. Twenty-three subjects underwent two swimming sessions at an ocean (salt water) pool (Maroubra beach Rock Pool, Sydney, Australia). Silicone hydrogel (Ciba Focus Night and Day) or hydrogel lenses (Ciba Focus Daily) were inserted into subjects' eyes before 30 min of swimming sessions, and subjects used modified goggles to mimic goggled and non-goggled conditions. At the end of each session, lenses were collected for microbial investigation. Viable bacterial colonies were classified as gram positive and gram negative and enumerated. The level of bacterial colonization on contact lenses between goggled and non-goggled conditions and between the two lens materials were compared. The range of colony forming units recovered from goggled lenses were 0 to 930 compared with 0 to 1210 on non-goggled lenses. The majority of subjects (16/23) had more microorganisms in the non-goggled condition than when wearing goggles (p = 0.03). Gram negative organisms were found in three non-goggled lenses. No significant difference was shown in the number of bacteria isolated from silicone hydrogel and hydrogel lenses (p > 0.6) irrespective of wearing goggles. Water samples had consistently higher numbers of bacterial counts than those adhered to the lenses; however, no association was found between the number of bacteria in the water sample and those found on the contact lenses. Consistently, fewer bacterial colonies were found on the goggled contact lens, thus suggesting goggles offer some protection against bacterial colonization of contact lenses while swimming. These data would support the recommendation encouraging lens wearers to use goggles

  5. Gunner Goggles: Implementing Augmented Reality into Medical Education.

    Science.gov (United States)

    Wang, Leo L; Wu, Hao-Hua; Bilici, Nadir; Tenney-Soeiro, Rebecca

    2016-01-01

    There is evidence that both smartphone and tablet integration into medical education has been lacking. At the same time, there is a niche for augmented reality (AR) to improve this process through the enhancement of textbook learning. Gunner Goggles is an attempt to enhance textbook learning in shelf exam preparatory review with augmented reality. Here we describe our initial prototype and detail the process by which augmented reality was implemented into our textbook through Layar. We describe the unique functionalities of our textbook pages upon augmented reality implementation, which includes links, videos and 3D figures, and surveyed 24 third year medical students for their impression of the technology. Upon demonstrating an initial prototype textbook chapter, 100% (24/24) of students felt that augmented reality improved the quality of our textbook chapter as a learning tool. Of these students, 92% (22/24) agreed that their shelf exam review was inadequate and 19/24 (79%) felt that a completed Gunner Goggles product would have been a viable alternative to their shelf exam review. Thus, while students report interest in the integration of AR into medical education test prep, future investigation into how the use of AR can improve performance on exams is warranted.

  6. Integration of visual and non-visual self-motion cues during voluntary head movements in the human brain.

    Science.gov (United States)

    Schindler, Andreas; Bartels, Andreas

    2018-05-15

    Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. A Comparison of the AVS-9 and the Panoramic Night Vision Goggles During Rotorcraft Hover and Landing

    Science.gov (United States)

    Szoboszlay, Zoltan; Haworth, Loran; Simpson, Carol

    2000-01-01

    A flight test was conducted to assess any differences in pilot-vehicle performance and pilot opinion between the use of a current generation night vision goggle (the AVS-9) and one variant of the prototype panoramic night vision goggle (the PNVGII). The panoramic goggle has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. Overall the panoramic goggles compared well to the AVS-9 goggles. However, pilot comment and data are consistent with the assertion that some of the benefits of additional field-of-view with the panoramic goggles were negated by the reduced image quality of the particular variant of the panoramic goggles tested.

  8. PLZT thermal/flash protective goggles: device concepts and constraints

    International Nuclear Information System (INIS)

    Cutchen, J.T.

    1979-01-01

    In 1975 Sandia Laboratories began the design and development of PLZT Goggles for the US Air Force to provide protection from temporary flashblindness and permanent retinal burns caused by the brilliant flash of nuclear explosions. The user requirements, system and physical constraints, and use/storage environments were all considered in arriving at the final design goals. When the program began, there was no industrial capability to manufacture large-aperture PLZT materials or bonded lens assemblies. The technology has been established from a laboratory baseline in a brief period, and operational testing and evaluation by the Air Force has been completed. The goggles, identified as the EEU-2/P,, are now in production

  9. Stroboscopic Goggles for Reduction of Motion Sickness

    Science.gov (United States)

    Reschke, M. F.; Somers, Jeffrey T.

    2005-01-01

    A device built around a pair of electronic shutters has been demonstrated to be effective as a prototype of stroboscopic goggles or eyeglasses for preventing or reducing motion sickness. The momentary opening of the shutters helps to suppress a phenomenon that is known in the art as retinal slip and is described more fully below. While a number of different environmental factors can induce motion sickness, a common factor associated with every known motion environment is sensory confusion or sensory mismatch. Motion sickness is a product of misinformation arriving at a central point in the nervous system from the senses from which one determines one s spatial orientation. When information from the eyes, ears, joints, and pressure receptors are all in agreement as to one s orientation, there is no motion sickness. When one or more sensory input(s) to the brain is not expected, or conflicts with what is anticipated, the end product is motion sickness. Normally, an observer s eye moves, compensating for the anticipated effect of motion, in such a manner that the image of an object moving relatively to an observer is held stationary on the retina. In almost every known environment that induces motion sickness, a change in the gain (in the signal-processing sense of gain ) of the vestibular system causes the motion of the eye to fail to hold images stationary on the retina, and the resulting motion of the images is termed retinal slip. The present concept of stroboscopic goggles or eyeglasses (see figure) is based on the proposition that prevention of retinal slip, and hence, the prevention of sensory mismatch, can be expected to reduce the tendency toward motion sickness. A device according to this concept helps to prevent retinal slip by providing snapshots of the visual environment through electronic shutters that are brief enough that each snapshot freezes the image on each retina. The exposure time for each snapshot is less than 5 ms. In the event that a higher

  10. New weather depiction technology for night vision goggle (NVG) training: 3D virtual/augmented reality scene-weather-atmosphere-target simulation

    Science.gov (United States)

    Folaron, Michelle; Deacutis, Martin; Hegarty, Jennifer; Vollmerhausen, Richard; Schroeder, John; Colby, Frank P.

    2007-04-01

    US Navy and Marine Corps pilots receive Night Vision Goggle (NVG) training as part of their overall training to maintain the superiority of our forces. This training must incorporate realistic targets; backgrounds; and representative atmospheric and weather effects they may encounter under operational conditions. An approach for pilot NVG training is to use the Night Imaging and Threat Evaluation Laboratory (NITE Lab) concept. The NITE Labs utilize a 10' by 10' static terrain model equipped with both natural and cultural lighting that are used to demonstrate various illumination conditions, and visual phenomena which might be experienced when utilizing night vision goggles. With this technology, the military can safely, systematically, and reliably expose pilots to the large number of potentially dangerous environmental conditions that will be experienced in their NVG training flights. A previous SPIE presentation described our work for NAVAIR to add realistic atmospheric and weather effects to the NVG NITE Lab training facility using the NVG - WDT(Weather Depiction Technology) system (Colby, et al.). NVG -WDT consist of a high end multiprocessor server with weather simulation software, and several fixed and goggle mounted Heads Up Displays (HUDs). Atmospheric and weather effects are simulated using state-of-the-art computer codes such as the WRF (Weather Research μ Forecasting) model; and the US Air Force Research Laboratory MODTRAN radiative transport model. Imagery for a variety of natural and man-made obscurations (e.g. rain, clouds, snow, dust, smoke, chemical releases) are being calculated and injected into the scene observed through the NVG via the fixed and goggle mounted HUDs. This paper expands on the work described in the previous presentation and will describe the 3D Virtual/Augmented Reality Scene - Weather - Atmosphere - Target Simulation part of the NVG - WDT. The 3D virtual reality software is a complete simulation system to generate realistic

  11. Feasibility of articulated arm mounted Oculus Rift Virtual Reality goggles for adjunctive pain control during occupational therapy in pediatric burn patients.

    Science.gov (United States)

    Hoffman, Hunter G; Meyer, Walter J; Ramirez, Maribel; Roberts, Linda; Seibel, Eric J; Atzori, Barbara; Sharar, Sam R; Patterson, David R

    2014-06-01

    For daily burn wound care and therapeutic physical therapy skin stretching procedures, powerful pain medications alone are often inadequate. This feasibility study provides the first evidence that entering an immersive virtual environment using very inexpensive (∼$400) wide field of view Oculus Rift Virtual Reality (VR) goggles can elicit a strong illusion of presence and reduce pain during VR. The patient was an 11-year-old male with severe electrical and flash burns on his head, shoulders, arms, and feet (36 percent total body surface area (TBSA), 27 percent TBSA were third-degree burns). He spent one 20-minute occupational therapy session with no VR, one with VR on day 2, and a final session with no VR on day 3. His rating of pain intensity during therapy dropped from severely painful during no VR to moderately painful during VR. Pain unpleasantness dropped from moderately unpleasant during no VR to mildly unpleasant during VR. He reported going "completely inside the computer generated world", and had more fun during VR. Results are consistent with a growing literature showing reductions in pain during VR. Although case studies are scientifically inconclusive by nature, these preliminary results suggest that the Oculus Rift VR goggles merit more attention as a potential treatment for acute procedural pain of burn patients. Availability of inexpensive but highly immersive VR goggles would significantly improve cost effectiveness and increase dissemination of VR pain distraction, making VR available to many more patients, potentially even at home, for pain control as well as a wide range of other VR therapy applications. This is the first clinical data on PubMed to show the use of Oculus Rift for any medical application.

  12. Heading-vector navigation based on head-direction cells and path integration.

    Science.gov (United States)

    Kubie, John L; Fenton, André A

    2009-05-01

    Insect navigation is guided by heading vectors that are computed by path integration. Mammalian navigation models, on the other hand, are typically based on map-like place representations provided by hippocampal place cells. Such models compute optimal routes as a continuous series of locations that connect the current location to a goal. We propose a "heading-vector" model in which head-direction cells or their derivatives serve both as key elements in constructing the optimal route and as the straight-line guidance during route execution. The model is based on a memory structure termed the "shortcut matrix," which is constructed during the initial exploration of an environment when a set of shortcut vectors between sequential pairs of visited waypoint locations is stored. A mechanism is proposed for calculating and storing these vectors that relies on a hypothesized cell type termed an "accumulating head-direction cell." Following exploration, shortcut vectors connecting all pairs of waypoint locations are computed by vector arithmetic and stored in the shortcut matrix. On re-entry, when local view or place representations query the shortcut matrix with a current waypoint and goal, a shortcut trajectory is retrieved. Since the trajectory direction is in head-direction compass coordinates, navigation is accomplished by tracking the firing of head-direction cells that are tuned to the heading angle. Section 1 of the manuscript describes the properties of accumulating head-direction cells. It then shows how accumulating head-direction cells can store local vectors and perform vector arithmetic to perform path-integration-based homing. Section 2 describes the construction and use of the shortcut matrix for computing direct paths between any pair of locations that have been registered in the shortcut matrix. In the discussion, we analyze the advantages of heading-based navigation over map-based navigation. Finally, we survey behavioral evidence that nonhippocampal

  13. Head-up and head-down displays integration in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gómez, Gilberto; Agudelo, J. David

    2014-06-01

    In automotive industry, the dashboard has been ergonomically developed in order to keep the driver focused on the horizon while driving, but the possibility to access external electronic devices constraints the driver to turn away his face, generating dangerous situations in spite of the short periods of time. Therefore, this work explores the integration of Head-Up Displays and Head-Down Displays in automobiles, proposing configurations that give to drivers the facility to driving focused. In this way, some of the main ergonomic comments about those configurations are proposed; and also, some technical comments regarding the implemented arrangements are given.

  14. Integrated head area design of KNGR to reduce refueling outage duration

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Woo Tae; Park, Chi Yong; Kim, In Hwan; Kim, Dae Woong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    In the design of KNGR (Korea Next Generation Reactor), we believe that economy is one of the most important factors to be considered. Thus, we reviewed and evaluated the consequences of designing the head area into an integrated package from an economical point of view. The refueling outage durations of the nuclear power plants currently in operation in Korea, some having and others not having integrated head package, are compared. This paper discusses the characteristics of head area design and the critical design issues of KNGR head area to evaluate the effect of the head area characteristics on the outage duration. 8 refs., 4 figs. (Author)

  15. Integrated head area design of KNGR to reduce refueling outage duration

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Woo Tae; Park, Chi Yong; Kim, In Hwan; Kim, Dae Woong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    In the design of KNGR (Korea Next Generation Reactor), we believe that economy is one of the most important factors to be considered. Thus, we reviewed and evaluated the consequences of designing the head area into an integrated package from an economical point of view. The refueling outage durations of the nuclear power plants currently in operation in Korea, some having and others not having integrated head package, are compared. This paper discusses the characteristics of head area design and the critical design issues of KNGR head area to evaluate the effect of the head area characteristics on the outage duration. 8 refs., 4 figs. (Author)

  16. A Comparison of the AVS-9 and the Panoramic Night Vision Goggle During Rotorcraft Hover and Landing

    Science.gov (United States)

    Szoboszlay, Zoltan; Haworth, Loran; Simpson, Carol; Rutkowski, Michael (Technical Monitor)

    2001-01-01

    The purpose of this flight test was to measure any differences in pilot-vehicle performance and pilot opinion between the use of the current generation AVS-9 Night Vision Goggle and one variant of the prototype Panoramic Night Vision Goggle (the PNV.GII). The PNVGII has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. The flight path of the AH-1S helicopter was used as a measure of pilot-vehicle performance. Also recorded were subjective measures of flying qualities, physical reserves of the pilot, situational awareness, and display usability. Pilot comment and data indicate that the benefits of additional FOV with the PNVGIIs are to some extent negated by the reduced image quality of the PNVGIIs.

  17. Night-vision goggles for night-blind subjects : subjective evaluation after 2 years of use

    NARCIS (Netherlands)

    Hartong, D. T.; Kooijman, A. C.

    Purpose: To evaluate the usefulness of night-vision goggles (NVG) for night-blind subjects after 1 and 2 years of use. Methods: Eleven night-blind subjects with retinitis pigmentosa used NVG for a 2-year period. At the end of each year, they were requested to fill-in two questionnaires regarding

  18. Manufacturing and properties of closure head forging integrated with flange for PWR reactor pressure vessel

    International Nuclear Information System (INIS)

    Tomoharu Sasaki; Iku Kurihara; Etsuo Murai; Yasuhiko Tanaka; Koumei Suzuki

    2003-01-01

    Closure head forging (SA508, Gr.3 Cl.1) integrated with flange for PWR reactor pressure vessel has been developed. This is intended to enhance structural integrity of closure head resulted in elimination of ISI, by eliminating weld joint between closure head and flange in the conventional design. Manufacturing procedures have been established so that homogeneity and isotropy of the material properties can be assured in the closure head forging integrated with flange. Acceptance tensile and impact test specimens are taken and tested regarding the closure head forging integrated with flange as very thick and complex forgings. This paper describes the manufacturing technologies and material properties of the closure head forging integrated with flange. (orig.)

  19. Visual-vestibular cue integration for heading perception: applications of optimal cue integration theory.

    Science.gov (United States)

    Fetsch, Christopher R; Deangelis, Gregory C; Angelaki, Dora E

    2010-05-01

    The perception of self-motion is crucial for navigation, spatial orientation and motor control. In particular, estimation of one's direction of translation, or heading, relies heavily on multisensory integration in most natural situations. Visual and nonvisual (e.g., vestibular) information can be used to judge heading, but each modality alone is often insufficient for accurate performance. It is not surprising, then, that visual and vestibular signals converge frequently in the nervous system, and that these signals interact in powerful ways at the level of behavior and perception. Early behavioral studies of visual-vestibular interactions consisted mainly of descriptive accounts of perceptual illusions and qualitative estimation tasks, often with conflicting results. In contrast, cue integration research in other modalities has benefited from the application of rigorous psychophysical techniques, guided by normative models that rest on the foundation of ideal-observer analysis and Bayesian decision theory. Here we review recent experiments that have attempted to harness these so-called optimal cue integration models for the study of self-motion perception. Some of these studies used nonhuman primate subjects, enabling direct comparisons between behavioral performance and simultaneously recorded neuronal activity. The results indicate that humans and monkeys can integrate visual and vestibular heading cues in a manner consistent with optimal integration theory, and that single neurons in the dorsal medial superior temporal area show striking correlates of the behavioral effects. This line of research and other applications of normative cue combination models should continue to shed light on mechanisms of self-motion perception and the neuronal basis of multisensory integration.

  20. Self-organizing path integration using a linked continuous attractor and competitive network: path integration of head direction.

    Science.gov (United States)

    Stringer, Simon M; Rolls, Edmund T

    2006-12-01

    A key issue is how networks in the brain learn to perform path integration, that is update a represented position using a velocity signal. Using head direction cells as an example, we show that a competitive network could self-organize to learn to respond to combinations of head direction and angular head rotation velocity. These combination cells can then be used to drive a continuous attractor network to the next head direction based on the incoming rotation signal. An associative synaptic modification rule with a short term memory trace enables preceding combination cell activity during training to be associated with the next position in the continuous attractor network. The network accounts for the presence of neurons found in the brain that respond to combinations of head direction and angular head rotation velocity. Analogous networks in the hippocampal system could self-organize to perform path integration of place and spatial view representations.

  1. Head-motion-controlled video goggles: preliminary concept for an interactive laparoscopic image display (i-LID).

    Science.gov (United States)

    Aidlen, Jeremy T; Glick, Sara; Silverman, Kenneth; Silverman, Harvey F; Luks, Francois I

    2009-08-01

    Light-weight, low-profile, and high-resolution head-mounted displays (HMDs) now allow personalized viewing, of a laparoscopic image. The advantages include unobstructed viewing, regardless of position at the operating table, and the possibility to customize the image (i.e., enhanced reality, picture-in-picture, etc.). The bright image display allows use in daylight surroundings and the low profile of the HMD provides adequate peripheral vision. Theoretic disadvantages include reliance for all on the same image capture and anticues (i.e., reality disconnect) when the projected image remains static, despite changes in head position. This can lead to discomfort and even nausea. We have developed a prototype of interactive laparoscopic image display that allows hands-free control of the displayed image by changes in spatial orientation of the operator's head. The prototype consists of an HMD, a spatial orientation device, and computer software to enable hands-free panning and zooming of a video-endoscopic image display. The spatial orientation device uses magnetic fields created by a transmitter and receiver, each containing three orthogonal coils. The transmitter coils are efficiently driven, using USB power only, by a newly developed circuit, each at a unique frequency. The HMD-mounted receiver system links to a commercially available PC-interface PCI-bus sound card (M-Audiocard Delta 44; Avid Technology, Tewksbury, MA). Analog signals at the receiver are filtered, amplified, and converted to digital signals, which are processed to control the image display. The prototype uses a proprietary static fish-eye lens and software for the distortion-free reconstitution of any portion of the captured image. Left-right and up-down motions of the head (and HMD) produce real-time panning of the displayed image. Motion of the head toward, or away from, the transmitter causes real-time zooming in or out, respectively, of the displayed image. This prototype of the interactive HMD

  2. Multifocal visual evoked responses to dichoptic stimulation using virtual reality goggles: Multifocal VER to dichoptic stimulation.

    Science.gov (United States)

    Arvind, Hemamalini; Klistorner, Alexander; Graham, Stuart L; Grigg, John R

    2006-05-01

    Multifocal visual evoked potentials (mfVEPs) have demonstrated good diagnostic capabilities in glaucoma and optic neuritis. This study aimed at evaluating the possibility of simultaneously recording mfVEP for both eyes with dichoptic stimulation using virtual reality goggles and also to determine the stimulus characteristics that yield maximum amplitude. ten healthy volunteers were recruited and temporally sparse pattern pulse stimuli were presented dichoptically using virtual reality goggles. Experiment 1 involved recording responses to dichoptically presented checkerboard stimuli and also confirming true topographic representation by switching off specific segments. Experiment 2 involved monocular stimulation and comparison of amplitude with Experiment 1. In Experiment 3, orthogonally oriented gratings were dichoptically presented. Experiment 4 involved dichoptic presentation of checkerboard stimuli at different levels of sparseness (5.0 times/s, 2.5 times/s, 1.66 times/s and 1.25 times/s), where stimulation of corresponding segments of two eyes were separated by 16.7, 66.7,116.7 & 166.7 ms respectively. Experiment 1 demonstrated good traces in all regions and confirmed topographic representation. However, there was suppression of amplitude of responses to dichoptic stimulation by 17.9+/-5.4% compared to monocular stimulation. Experiment 3 demonstrated similar suppression between orthogonal and checkerboard stimuli (p = 0.08). Experiment 4 demonstrated maximum amplitude and least suppression (4.8%) with stimulation at 1.25 times/s with 166.7 ms separation between eyes. It is possible to record mfVEP for both eyes during dichoptic stimulation using virtual reality goggles, which present binocular simultaneous patterns driven by independent sequences. Interocular suppression can be almost eliminated by using a temporally sparse stimulus of 1.25 times/s with a separation of 166.7 ms between stimulation of corresponding segments of the two eyes.

  3. The study and development of magnetic recording heads. A thin film integrated magnetic head

    International Nuclear Information System (INIS)

    Lazzari, Jean-Pierre

    1970-01-01

    A new integrated magnetic head is described. The head was made by vacuum deposition using a mask. A magnetically coupled multilayer construction led to high performance. The results obtained indicate that the device functions equally well, for reading and writing. A set of calculations was developed which could simulate and optimize the behavior of the recording head. The results obtained with the writing were in good agreement with those obtained from experiments and quite different from results which have been several times previously published. In addition a new method was developed for measuring high fields in confined spaces; a 1000 A diameter probe was used in conjunction with a low angle diffraction procedure. The measurements give results which are very different from those obtained by current theories based on the magnetic potentials at the surface. (author) [fr

  4. Human Papillomavirus Genome Integration and Head and Neck Cancer.

    Science.gov (United States)

    Pinatti, L M; Walline, H M; Carey, T E

    2018-06-01

    We conducted a critical review of human papillomavirus (HPV) integration into the host genome in oral/oropharyngeal cancer, reviewed the literature for HPV-induced cancers, and obtained current data for HPV-related oral and oropharyngeal cancers. In addition, we performed studies to identify HPV integration sites and the relationship of integration to viral-host fusion transcripts and whether integration is required for HPV-associated oncogenesis. Viral integration of HPV into the host genome is not required for the viral life cycle and might not be necessary for cellular transformation, yet HPV integration is frequently reported in cervical and head and neck cancer specimens. Studies of large numbers of early cervical lesions revealed frequent viral integration into gene-poor regions of the host genome with comparatively rare integration into cellular genes, suggesting that integration is a stochastic event and that site of integration may be largely a function of chance. However, more recent studies of head and neck squamous cell carcinomas (HNSCCs) suggest that integration may represent an additional oncogenic mechanism through direct effects on cancer-related gene expression and generation of hybrid viral-host fusion transcripts. In HNSCC cell lines as well as primary tumors, integration into cancer-related genes leading to gene disruption has been reported. The studies have shown that integration-induced altered gene expression may be associated with tumor recurrence. Evidence from several studies indicates that viral integration into genic regions is accompanied by local amplification, increased expression in some cases, interruption of gene expression, and likely additional oncogenic effects. Similarly, reported examples of viral integration near microRNAs suggest that altered expression of these regulatory molecules may also contribute to oncogenesis. Future work is indicated to identify the mechanisms of these events on cancer cell behavior.

  5. Lower head integrity under steam explosion loads

    Energy Technology Data Exchange (ETDEWEB)

    Theofanous, T.G.; Yuen, W.W.; Angelini, S.; Freeman, K.; Chen, X.; Salmassi, T. [Center for Risk Studies and Safety, Univ. of California, Santa Barbara, CA (United States); Sienicki, J.J.

    1998-01-01

    Lower head integrity under steam explosion loads in an AP600-like reactor design is considered. The assessment is the second part of an evaluation of the in-vessel retention idea as a severe accident management concept, the first part (DOE/ID-10460) dealing with thermal loads. The assessment is conducted in terms of the Risk Oriented Accident Analysis Methodology (ROAAM), and includes the comprehensive evaluation of all relevant severe accident scenarios, melt conditions and timing of release from the core region, fully 3D mixing and explosion wave dynamics, and lower head fragility under local, dynamic loading. All of these factors and brought together in a ROAAM Probabilistic Framework to evaluate failure likelihood. The conclusion is that failure is `physically unreasonable`. (author)

  6. Design Formulae for Hydraulic Stability and Structural Integrity of Dolos Breakwater Round-Heads

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Jensen, Jacob Birk; Liu, Z.

    1995-01-01

    A rational design of Dolos armour unit should incorporate both the hydraulic stability and the structural integrity. The previous tests performed by Aalborg University (AU) resulted in design formulae for the trunk of a 1:1.5 slope Dolos breakwater without superstructure including both...... the hydraulic stability and the structural integrity. The objective of the round-head tests is to produce similar design formulae for Dolos armour in around-head. The tests will also include examinations of the hydraulic stability and run-up for a trunk section adjacent to the round-head. A run-up formula...

  7. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  8. Path integration of head direction: updating a packet of neural activity at the correct speed using axonal conduction delays.

    Science.gov (United States)

    Walters, Daniel; Stringer, Simon; Rolls, Edmund

    2013-01-01

    The head direction cell system is capable of accurately updating its current representation of head direction in the absence of visual input. This is known as the path integration of head direction. An important question is how the head direction cell system learns to perform accurate path integration of head direction. In this paper we propose a model of velocity path integration of head direction in which the natural time delay of axonal transmission between a linked continuous attractor network and competitive network acts as a timing mechanism to facilitate the correct speed of path integration. The model effectively learns a "look-up" table for the correct speed of path integration. In simulation, we show that the model is able to successfully learn two different speeds of path integration across two different axonal conduction delays, and without the need to alter any other model parameters. An implication of this model is that, by learning look-up tables for each speed of path integration, the model should exhibit a degree of robustness to damage. In simulations, we show that the speed of path integration is not significantly affected by degrading the network through removing a proportion of the cells that signal rotational velocity.

  9. Phototherapy and orange-tinted goggles for night-shift adaptation of police officers on patrol.

    Science.gov (United States)

    Boivin, Diane B; Boudreau, Philippe; Tremblay, Geneviève M

    2012-06-01

    The aim of the present combined field and laboratory study was to assess circadian entrainment in two groups of police officers working seven consecutive 8/8.5-h night shifts as part of a rotating schedule. Eight full-time police officers on patrol (mean age ± SD: 29.8 ± 6.5 yrs) were provided an intervention consisting of intermittent exposure to wide-spectrum bright light at night, orange-tinted goggles at sunrise, and maintenance of a regular sleep/darkness episode in the day. Orange-tinted goggles have been shown to block the melatonin-suppressing effect of light significantly more than neutral gray density goggles. Nine control group police officers (mean age ± SD: 30.3 ± 4.1 yrs) working the same schedule were enrolled. Police officers were studied before, after (in the laboratory), and during (ambulatory) a series of seven consecutive nights. Urine samples were collected at wake time and bedtime throughout the week of night work and during laboratory visits (1 × /3 h) preceding and following the work week to measure urinary 6-sulfatoxymelatonin (UaMT6s) excretion rate. Subjective alertness was assessed at the start, middle, and end of night shifts. A 10-min psychomotor vigilance task was performed at the start and end of each shift. Both laboratory visits consisted of two 8-h sleep episodes based on the prior schedule. Saliva samples were collected 2 × /h during waking episodes to assay their melatonin content. Subjective alertness (3 × /h) and performance (1 × /2 h) were assessed during wake periods in the laboratory. A mixed linear model was used to analyze the progression of UaMt6s excreted during daytime sleep episodes at home, as well as psychomotor performance and subjective alertness during night shifts. Two-way analysis of variance (ANOVA) (factors: laboratory visit and group) were used to compare peak salivary melatonin and UaMT6s excretion rate in the laboratory. In both groups of police officers, the excretion rate of UaMT6s at home was

  10. Assessment of the Effectiveness of Combat Eyewear Protection Against Blast Overpressure.

    Science.gov (United States)

    Sundaramurthy, A; Skotak, M; Alay, E; Unnikrishnan, G; Mao, H; Duan, X; Williams, S T; Harding, T H; Chandra, N; Reifman, J

    2018-07-01

    It is unclear whether combat eyewear used by U. S. Service members is protective against blast overpressures (BOPs) caused by explosive devices. Here, we investigated the mechanisms by which BOP bypasses eyewear and increases eye surface pressure. We performed experiments and developed three-dimensional (3D) finite element (FE) models of a head form (HF) equipped with an advanced combat helmet (ACH) and with no eyewear, spectacles, or goggles in a shock tube at three BOPs and five head orientations relative to the blast wave. Overall, we observed good agreement between experimental and computational results, with average discrepancies in impulse and peak-pressure values of less than 15% over 90 comparisons. In the absence of eyewear and depending on the head orientation, we identified three mechanisms that contributed to pressure loading on the eyes. Eyewear was most effective at 0 deg orientation, with pressure attenuation ranging from 50 (spectacles) to 80% (goggles) of the peak pressures observed in the no-eyewear configuration. Spectacles and goggles were considerably less effective when we rotated the HF in the counter-clockwise direction around the superior-inferior axis of the head. Surprisingly, at certain orientations, spectacles yielded higher maximum pressures (80%) and goggles yielded larger impulses (150%) than those observed without eyewear. The findings from this study will aid in the design of eyewear that provides better protection against BOP.

  11. Integrity evaluation of Alloy 600 RV head penetration tubes in Korean PWR plants

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Park, Sung Ho; Hong, Sung Yull; Choi, Kwang Hee

    1995-01-01

    The structural integrity assessment of Alloy 600 RV head penetration tubes has been an important issue for the economical and reliable operation of power plants. In this paper, an overview of the integrity evaluation program for the RV head penetration tubes in Korean nuclear power plants is presented. Since the crack growth mechanism of the penetration tube is due to the primary water stress corrosion cracking (PWSCC) which is mainly related to the stress at the tube, the present paper consists of three primary activities: the stress evaluation, the flaw evaluation, and data generation through material and mechanical tests. (author). 5 refs, 2 figs, 1 tab

  12. WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mittauer, K; Yan, G; Lu, B; Barraclough, B; Li, J; Liu, C [University of Florida, Gainesville, FL (United States)

    2014-06-15

    Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The

  13. [Oral maxillofacial-head and neck tumor and holistic integrative medicine].

    Science.gov (United States)

    Zhang, C P

    2017-08-09

    The advance of clinical diagnosis and treatment in oral and maxillofacial-head and neck tumors has been through the process of specialization and multidisciplinary cooperation. In most cases, a single discipline cannot meet the requirements of diagnosis and treatment, which needs the cooperation of oral and maxillofacial surgery, otolaryngology and oncology approach and therapeutic method such as surgery, radiotherapy and chemotherapy. Holistic integrative medicine aims at integrating the most effective clinical practice experience and patients' individual situation and prognosis, establishing new medical mode conforming to the modern concept and fulfilling the medical system adapting to the specific characteristics of the diseases.

  14. Integration of visual and inertial cues in perceived heading of self-motion

    NARCIS (Netherlands)

    Winkel, K.N. de; Weesie, H.M.; Werkhoven, P.J.; Groen, E.L.

    2010-01-01

    In the present study, we investigated whether the perception of heading of linear self-motion can be explained by Maximum Likelihood Integration (MLI) of visual and non-visual sensory cues. MLI predicts smaller variance for multisensory judgments compared to unisensory judgments. Nine participants

  15. A homolog of Drosophila grainy head is essential for epidermal integrity in mice.

    Science.gov (United States)

    Ting, Stephen B; Caddy, Jacinta; Hislop, Nikki; Wilanowski, Tomasz; Auden, Alana; Zhao, Lin-Lin; Ellis, Sarah; Kaur, Pritinder; Uchida, Yoshikazu; Holleran, Walter M; Elias, Peter M; Cunningham, John M; Jane, Stephen M

    2005-04-15

    The Drosophila cuticle is essential for maintaining the surface barrier defenses of the fly. Integral to cuticle resilience is the transcription factor grainy head, which regulates production of the enzyme required for covalent cross-linking of the cuticular structural components. We report that formation and maintenance of the epidermal barrier in mice are dependent on a mammalian homolog of grainy head, Grainy head-like 3. Mice lacking this factor display defective skin barrier function and deficient wound repair, accompanied by reduced expression of transglutaminase 1, the key enzyme involved in cross-linking the structural components of the superficial epidermis. These findings suggest that the functional mechanisms involving protein cross-linking that maintain the epidermal barrier and induce tissue repair are conserved across 700 million years of evolution.

  16. Neck Kinematics and Electromyography While Wearing Head Supported Mass During Running.

    Science.gov (United States)

    Hanks, Matthew M; Sefton, JoEllen M; Oliver, Gretchen D

    2018-01-01

    Advanced combat helmets (ACH) coupled with night-vision goggles (NVG) are required for tactical athletes during training and service. Head and neck injuries due to head supported mass (HSM) are a common occurrence in military personnel. The current study aimed to investigate the effects of HSM on neck muscle fatigue that may lead to chronic stress and injury of the head and neck. Subjects wore an ACH and were affixed with electromagnetic sensors to obtain kinematic data, as well as EMG electrodes to obtain muscle activations of bilateral sternocleidomastoid, upper trapezius, and paraspinal muscles while running on a treadmill. Subjects performed a 2-min warmup at a walking pace, a 5-min warmup jog, running at a pace equal to 90% maximum heart rate until absolute fatigue, and lastly a 2-min cooldown at a walking pace. Kinematic and EMG data were collected over each 2-min interval. Days later, the same subjects wore the same ACH in addition to the NVG and performed the same protocol as the first session. This study showed significant differences in muscle activation of the right upper trapezius [F(1,31) = 10.100] and both sternocleidomastoid [F(1,31) = 12.280] muscles from pre-fatigue to absolute fatigue. There were no significant differences noted in the kinematic variables. This study suggests that HSM can fatigue bilateral neck flexors and rotators, as well as fatigue the neck extensors and rotators on the contralateral side of the mounted NVG.Hanks MM, Sefton JM, Oliver GD. Neck kinematics and electromyography while wearing head supported mass during running. Aerosp Med Hum Perform. 2018; 89(1):9-13.

  17. CFD Analysis for Advanced Integrated Head Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Won Ho; Kang, Tae Kyo; Cho, Yeon Ho; Kim, Hyun Min [KEPCO Engineering and Construction Co., Daejeon (Korea, Republic of)

    2016-10-15

    The Integrated Head Assembly (IHA) is permanently installed on the reactor vessel closure head during the normal plant operation and refueling operation. It consists of a number of systems and components such as the head lifting system, seismic support system, Control Element Drive Mechanism (CEDM) cooling system, cable support system, cooling shroud assemblies. With the operating experiences of the IHA, the needs for the design change to the current APR1400 IHA arouse to improve the seismic resistance and to accommodate the convenient maintenance. In this paper, the effects of the design changes were rigorously studied for the various sizes of the inlet openings to assure the proper cooling of the CEDMs. And the system pressure differentials and required flow rate for the CEDM cooling fan were analyzed regarding the various operating conditions for determining the capacity of the fan. As a part of the design process of the AIHA, the number of air inlets and baffle regions are reduced by simplifying the design of the APR1400 IHA. The design change of the baffle regions has been made such that the maximum possible space are occupied inside the IHA cooling shroud shell while avoiding the interference with CEDMs. So, only the air inlet opening was studied for the design change to supply a sufficient cooling air flow for each CEDM. The size and location of the air inlets in middle cooling shroud assembly were determined by the CFD analyses of the AIHA. And the case CFD analyses were performed depending on the ambient air temperature and fan operating conditions. The size of the air inlet openings is increased by comparison with the initial AIHA design, and it is confirmed that the cooling air flow rate for each CEDM meet the design requirement of 800 SCFM ± 10% with the increased air inlets. At the initial analysis, the fan outlet flow rate was assumed as 48.3 lbm/s, but the result revealed that the less outflow rate at the fan is enough to meet the design requirement

  18. The Effects of the Personal Armor System for Ground Troops (PASGT) and the Advanced Combat Helmet (ACH) with and without PVS-14 Night Vision Goggles (NVG) on Neck Biomechanics During Dismounted Soldier Movements

    National Research Council Canada - National Science Library

    LaFiandra, Michael; Harman, Everett; Cornelius, Nancy; Frykman, Peter; Gutekunst, David; Nelson, Gabe

    2007-01-01

    Kevlar helmets provide the soldier with basic ballistic and impact protection. However, the helmet has recently become a mounting platform for devices such as night-vision goggles, drop down displays, weapon-aiming systems, etc...

  19. Development of an Automatic Testing Platform for Aviator’s Night Vision Goggle Honeycomb Defect Inspection

    Directory of Open Access Journals (Sweden)

    Bo-Lin Jian

    2017-06-01

    Full Text Available Due to the direct influence of night vision equipment availability on the safety of night-time aerial reconnaissance, maintenance needs to be carried out regularly. Unfortunately, some defects are not easy to observe or are not even detectable by human eyes. As a consequence, this study proposed a novel automatic defect detection system for aviator’s night vision imaging systems AN/AVS-6(V1 and AN/AVS-6(V2. An auto-focusing process consisting of a sharpness calculation and a gradient-based variable step search method is applied to achieve an automatic detection system for honeycomb defects. This work also developed a test platform for sharpness measurement. It demonstrates that the honeycomb defects can be precisely recognized and the number of the defects can also be determined automatically during the inspection. Most importantly, the proposed approach significantly reduces the time consumption, as well as human assessment error during the night vision goggle inspection procedures.

  20. Toward integration of genomic selection with crop modelling: the development of an integrated approach to predicting rice heading dates.

    Science.gov (United States)

    Onogi, Akio; Watanabe, Maya; Mochizuki, Toshihiro; Hayashi, Takeshi; Nakagawa, Hiroshi; Hasegawa, Toshihiro; Iwata, Hiroyoshi

    2016-04-01

    It is suggested that accuracy in predicting plant phenotypes can be improved by integrating genomic prediction with crop modelling in a single hierarchical model. Accurate prediction of phenotypes is important for plant breeding and management. Although genomic prediction/selection aims to predict phenotypes on the basis of whole-genome marker information, it is often difficult to predict phenotypes of complex traits in diverse environments, because plant phenotypes are often influenced by genotype-environment interaction. A possible remedy is to integrate genomic prediction with crop/ecophysiological modelling, which enables us to predict plant phenotypes using environmental and management information. To this end, in the present study, we developed a novel method for integrating genomic prediction with phenological modelling of Asian rice (Oryza sativa, L.), allowing the heading date of untested genotypes in untested environments to be predicted. The method simultaneously infers the phenological model parameters and whole-genome marker effects on the parameters in a Bayesian framework. By cultivating backcross inbred lines of Koshihikari × Kasalath in nine environments, we evaluated the potential of the proposed method in comparison with conventional genomic prediction, phenological modelling, and two-step methods that applied genomic prediction to phenological model parameters inferred from Nelder-Mead or Markov chain Monte Carlo algorithms. In predicting heading dates of untested lines in untested environments, the proposed and two-step methods tended to provide more accurate predictions than the conventional genomic prediction methods, particularly in environments where phenotypes from environments similar to the target environment were unavailable for training genomic prediction. The proposed method showed greater accuracy in prediction than the two-step methods in all cross-validation schemes tested, suggesting the potential of the integrated approach in

  1. Integration Head Mounted Display Device and Hand Motion Gesture Device for Virtual Reality Laboratory

    Science.gov (United States)

    Rengganis, Y. A.; Safrodin, M.; Sukaridhoto, S.

    2018-01-01

    Virtual Reality Laboratory (VR Lab) is an innovation for conventional learning media which show us whole learning process in laboratory. There are many tools and materials are needed by user for doing practical in it, so user could feel new learning atmosphere by using this innovation. Nowadays, technologies more sophisticated than before. So it would carry in education and it will be more effective, efficient. The Supported technologies are needed us for making VR Lab such as head mounted display device and hand motion gesture device. The integration among them will be used us for making this research. Head mounted display device for viewing 3D environment of virtual reality laboratory. Hand motion gesture device for catching user real hand and it will be visualized in virtual reality laboratory. Virtual Reality will show us, if using the newest technologies in learning process it could make more interesting and easy to understand.

  2. Perceiving where another person is looking: The integration of head and body information in estimating another person’s gaze.

    Directory of Open Access Journals (Sweden)

    Pieter eMoors

    2015-06-01

    Full Text Available The process through which an observer allocates his/her attention based on the attention of another person is known as joint attention. To be able to do this, the observer effectively has to compute where the other person is looking. It has been shown that observers integrate information from the head and the eyes to determine the gaze of another person. Most studies have documented that observers show a bias called the overshoot effect when eyes and head are misaligned. The present study addresses whether body information is also used as a cue to compute perceived gaze direction. In Experiment 1, we observed a similar overshoot effect in both behavioral and saccadic responses when manipulating body orientation. In Experiment 2, we explored whether the overshoot effect was due to observers assuming that the eyes are oriented further than the head when head and body orientation are misaligned. We removed horizontal eye information by presenting the stimulus from a side view. Head orientation was now manipulated in a vertical direction and the overshoot effect was replicated. In summary, this study shows that body orientation is indeed used as a cue to determine where another person is looking.

  3. Raman laser spectrometer optical head: qualification model assembly and integration verification

    Science.gov (United States)

    Ramos, G.; Sanz-Palomino, M.; Moral, A. G.; Canora, C. P.; Belenguer, T.; Canchal, R.; Prieto, J. A. R.; Santiago, A.; Gordillo, C.; Escribano, D.; Lopez-Reyes, G.; Rull, F.

    2017-08-01

    Raman Laser Spectrometer (RLS) is the Pasteur Payload instrument of the ExoMars mission, within the ESA's Aurora Exploration Programme, that will perform for the first time in an out planetary mission Raman spectroscopy. RLS is composed by SPU (Spectrometer Unit), iOH (Internal Optical Head), and ICEU (Instrument Control and Excitation Unit). iOH focuses the excitation laser on the samples (excitation path), and collects the Raman emission from the sample (collection path, composed on collimation system and filtering system). Its original design presented a high laser trace reaching to the detector, and although a certain level of laser trace was required for calibration purposes, the high level degrades the Signal to Noise Ratio confounding some Raman peaks. So, after the bread board campaign, some light design modifications were implemented in order to fix the desired amount of laser trace, and after the fabrication and the commitment of the commercial elements, the assembly and integration verification process was carried out. A brief description of the iOH design update for the engineering and qualification model (iOH EQM) as well as the assembly process are briefly described in this papers. In addition, the integration verification and the first functional tests, carried out with the RLS calibration target (CT), results are reported on.

  4. A self-report critical incident assessment tool for army night vision goggle helicopter operations.

    Science.gov (United States)

    Renshaw, Peter F; Wiggins, Mark W

    2007-04-01

    The present study sought to examine the utility of a self-report tool that was designed as a partial substitute for a face-to-face cognitive interview for critical incidents involving night vision goggles (NVGs). The use of NVGs remains problematic within the military environment, as these devices have been identified as a factor in a significant proportion of aircraft accidents and incidents. The self-report tool was structured to identify some of the cognitive features of human performance that were associated with critical incidents involving NVGs. The tool incorporated a number of different levels of analysis, ranging from specific behavioral responses to broader cognitive constructs. Reports were received from 30 active pilots within the Australian Army using the NVG Critical Incident Assessment Tool (NVGCIAT). The results revealed a correspondence between specific types of NVG-related errors and elements of the Human Factors Analysis and Classification System (HFACS). In addition, uncertainty emerged as a significant factor associated with the critical incidents that were recalled by operators. These results were broadly consistent with previous research and provide some support for the utility of subjective assessment tools as a means of extracting critical incident-related data when face-to-face cognitive interviews are not possible. In some circumstances, the NVGCIAT might be regarded as a substitute cognitive interview protocol with some level of diagnosticity.

  5. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients

    International Nuclear Information System (INIS)

    Penoncello, Gregory P.; Ding, George X.

    2016-01-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2 cm"3 for head and neck plans and brain plans and a contiguous volume of 5 cm"3 for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens.

  6. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients.

    Science.gov (United States)

    Penoncello, Gregory P; Ding, George X

    2016-01-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2cm(3) for head and neck plans and brain plans and a contiguous volume of 5cm(3) for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens. Copyright © 2016 American Association of Medical Dosimetrists. Published by

  7. Integrated Model of the Eye/Optic Nerve Head Biomechanical Environment

    Science.gov (United States)

    Ethier, C. R.; Feola, A.; Myers, J. G.; Nelson, E.; Raykin, J.; Samuels, B.

    2017-01-01

    Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Previously, it has been suggested that ocular changes observed in VIIP syndrome are related to the cephalad fluid shift that results in altered fluid pressures [1]. We are investigating the impact of changes in intracranial pressure (ICP) using a combination of numerical models, which simulate the effects of various environment conditions, including finite element (FE) models of the posterior eye. The specific interest is to understand how altered pressures due to gravitational changes affect the biomechanical environment of tissues of the posterior eye and optic nerve sheath. METHODS: Additional description of the numerical modeling is provided in the IWS abstract by Nelson et al. In brief, to simulate the effects of a cephalad fluid shift on the cardiovascular and ocular systems, we utilized a lumped-parameter compartment model of these systems. The outputs of this lumped-parameter model then inform boundary conditions (pressures) for a finite element model of the optic nerve head (Figure 1). As an example, we show here a simulation of postural change from supine to 15 degree head-down tilt (HDT), with primary outcomes being the predicted change in strains at the optic nerve head (ONH) region, specifically in the lamina cribrosa (LC), retrolaminar optic nerve, and prelaminar neural tissue (PLNT). The strain field can be decomposed into three orthogonal components, denoted as the first, second and third principal strains. We compare the peak tensile (first principal) and compressive (third principal) strains, since elevated strain alters cell phenotype and induces tissue remodeling. RESULTS AND CONCLUSIONS: Our lumped-parameter model predicted an IOP increase of c. 7 mmHg after 21 minutes of 15 degree HDT, which agreed with previous reports of IOP in HDT [1]. The corresponding FEM simulations predicted a relative increase in the magnitudes of the peak tensile

  8. Measuring How the Head of Department Measures Up: Development of an Evaluation Framework for the Head of Department Role

    Science.gov (United States)

    London, Chad

    2011-01-01

    The head of department position has been an integral role in the organisational structure of colleges and universities for over a hundred years. Recently, many institutions of higher education have called on department heads to provide advancing quality management and leadership to academic units in response to an increasingly complex and…

  9. Advances and trends of head-up and head-down display systems in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gomez, Gilberto; Agudelo, J. David

    2014-06-01

    Currently, in the automotive industry the interaction between drivers and Augmented Reality (AR) systems is a subject of analysis, especially the identification of advantages and risks that this kind of interaction represents. Consequently, this paper attempts to put in evidence the potential applications of Head-Up (Display (HUD) and Head-Down Display (HDD) systems in automotive vehicles, showing applications and trends under study. In general, automotive advances related to AR devices suggest the partial integration of the HUD and HDD in automobiles; however, the right way to do it is still a moot point.

  10. [Duodenum-preserving total pancreatic head resection and pancreatic head resection with segmental duodenostomy].

    Science.gov (United States)

    Takada, Tadahiro; Yasuda, Hideki; Nagashima, Ikuo; Amano, Hodaka; Yoshiada, Masahiro; Toyota, Naoyuki

    2003-06-01

    A duodenum-preserving pancreatic head resection (DPPHR) was first reported by Beger et al. in 1980. However, its application has been limited to chronic pancreatitis because of it is a subtotal pancreatic head resection. In 1990, we reported duodenum-preserving total pancreatic head resection (DPTPHR) in 26 cases. This opened the way for total pancreatic head resection, expanding the application of this approach to tumorigenic morbidities such as intraductal papillary mucinous tumor (IMPT), other benign tumors, and small pancreatic cancers. On the other hand, Nakao et al. reported pancreatic head resection with segmental duodenectomy (PHRSD) as an alternative pylorus-preserving pancreatoduodenectomy technique in 24 cases. Hirata et al. also reported this technique as a new pylorus-preserving pancreatoduodenostomy with increased vessel preservation. When performing DPTPHR, the surgeon should ensure adequate duodenal blood supply. Avoidance of duodenal ischemia is very important in this operation, and thus it is necessary to maintain blood flow in the posterior pancreatoduodenal artery and to preserve the mesoduodenal vessels. Postoperative pancreatic functional tests reveal that DPTPHR is superior to PPPD, including PHSRD, because the entire duodenum and duodenal integrity is very important for postoperative pancreatic function.

  11. Integrated approach for stress analysis of high performance diesel engine cylinder head

    Science.gov (United States)

    Chainov, N. D.; Myagkov, L. L.; Malastowski, N. S.; Blinov, A. S.

    2018-03-01

    Growing thermal and mechanical loads due to development of engines with high level of a mean effective pressure determine requirements to cylinder head durability. In this paper, computational schemes for thermal and mechanical stress analysis of a high performance diesel engine cylinder head were described. The most important aspects in this approach are the account of temperature fields of conjugated details (valves and saddles), heat transfer modeling in a cooling jacket of a cylinder head and topology optimization of the detail force scheme. Simulation results are shown and analyzed.

  12. Path integration of head direction: updating a packet of neural activity at the correct speed using neuronal time constants.

    Science.gov (United States)

    Walters, D M; Stringer, S M

    2010-07-01

    A key question in understanding the neural basis of path integration is how individual, spatially responsive, neurons may self-organize into networks that can, through learning, integrate velocity signals to update a continuous representation of location within an environment. It is of vital importance that this internal representation of position is updated at the correct speed, and in real time, to accurately reflect the motion of the animal. In this article, we present a biologically plausible model of velocity path integration of head direction that can solve this problem using neuronal time constants to effect natural time delays, over which associations can be learned through associative Hebbian learning rules. The model comprises a linked continuous attractor network and competitive network. In simulation, we show that the same model is able to learn two different speeds of rotation when implemented with two different values for the time constant, and without the need to alter any other model parameters. The proposed model could be extended to path integration of place in the environment, and path integration of spatial view.

  13. Latency requirements for head-worn display S/EVS applications

    Science.gov (United States)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  14. Heads First: Visual Aftereffects Reveal Hierarchical Integration of Cues to Social Attention.

    Directory of Open Access Journals (Sweden)

    Sarah Cooney

    Full Text Available Determining where another person is attending is an important skill for social interaction that relies on various visual cues, including the turning direction of the head and body. This study reports a novel high-level visual aftereffect that addresses the important question of how these sources of information are combined in gauging social attention. We show that adapting to images of heads turned 25° to the right or left produces a perceptual bias in judging the turning direction of subsequently presented bodies. In contrast, little to no change in the judgment of head orientation occurs after adapting to extremely oriented bodies. The unidirectional nature of the aftereffect suggests that cues from the human body signaling social attention are combined in a hierarchical fashion and is consistent with evidence from single-cell recording studies in nonhuman primates showing that information about head orientation can override information about body posture when both are visible.

  15. Night vision goggle stimulation using LCoS and DLP projection technology, which is better?

    Science.gov (United States)

    Ali, Masoud H.; Lyon, Paul; De Meerleer, Peter

    2014-06-01

    High fidelity night-vision training has become important for many of the simulation systems being procured today. The end-users of these simulation-training systems prefer using their actual night-vision goggle (NVG) headsets. This requires that the visual display system stimulate the NVGs in a realistic way. Historically NVG stimulation was done with cathode-ray tube (CRT) projectors. However, this technology became obsolete and in recent years training simulators do NVG stimulation with laser, LCoS and DLP projectors. The LCoS and DLP projection technologies have emerged as the preferred approach for the stimulation of NVGs. Both LCoS and DLP technologies have advantages and disadvantages for stimulating NVGs. LCoS projectors can have more than 5-10 times the contrast capability of DLP projectors. The larger the difference between the projected black level and the brightest object in a scene, the better the NVG stimulation effects can be. This is an advantage of LCoS technology, especially when the proper NVG wavelengths are used. Single-chip DLP projectors, even though they have much reduced contrast compared to LCoS projectors, can use LED illuminators in a sequential red-green-blue fashion to create a projected image. It is straightforward to add an extra infrared (NVG wavelength) LED into this sequential chain of LED illumination. The content of this NVG channel can be independent of the visible scene, which allows effects to be added that can compensate for the lack of contrast inherent in a DLP device. This paper will expand on the differences between LCoS and DLP projectors for stimulating NVGs and summarize the benefits of both in night-vision simulation training systems.

  16. Design of an integral missile shield in integrated head assembly for pressurized water reactor at commercial nuclear plants

    International Nuclear Information System (INIS)

    Baliga, Ravi; Watts, Tom Neal; Kamath, Harish

    2015-01-01

    In ICONE22, the authors presented the Integrated Head Assembly (IHA) design concept implemented at Callaway Nuclear Power Plant in Missouri, USA. The IHA concept is implemented to reduce the outage duration and the associated radiation exposure to the workers by reducing critical path time during Plant Refueling Outage. One of the head area components in the IHA is a steel missile shield designed to protect the Control Rod Drive Mechanism (CRDM) assembly from damaging other safety-related components in the vicinity in the Containment. Per Federally implemented General Design Criteria for commercial nuclear plants in the USA, the design of Nuclear Steam Supply System (NSSS) must provide protection from the damages caused by a postulated event of CRDM housing units and their associated parts disengaging from the reactor vessel assembly. This event is considered as a Loss of Coolant Accident (LOCA) and assumes that once the CRDM housing unit and their associated parts disengage from the reactor vessel internals assembly, they travel upward by the water jet with the following sequence of events: Per Reference 1, the drive shaft and control rod cluster are forced out of the reactor core by the differential pressure across the drive shaft with the assumption that the drive shaft and control rod cluster, latched together, are fully inserted when the accident occurs. After the travel, the rod cluster control spider will impact the lower side of the upper support plate inside the reactor vessel fracturing the flexure arms in the joint freeing the drive shaft from the control rod cluster. The control rod cluster is stopped by the upper support plate and will remain below the upper support plate during this accident. However, the drive shaft will continue to accelerate in the upward direction until it is stopped by a safety feature in the IHA. The integral missile shield as a safety feature in the IHA is designed to stop the CRDM drive shaft from moving further up in the

  17. Planning and Reviewing for Success. Training Guides for the Head Start Learning Community.

    Science.gov (United States)

    Aspen Systems Corp., Rockville, MD.

    This guide offers Head Start staff a blueprint for developing the skills and methods necessary for a Head Start program's planning and review process. The guide stresses the need for Head Start administrative and managerial leadership to maintain a holistic, integrated approach; use the strength and resources of Head Start team members; identify…

  18. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography

    Science.gov (United States)

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S.; Kuo, Anthony N.; Toth, Cynthia A.; Izatt, Joseph A.

    2016-01-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes. PMID:27231616

  19. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography.

    Science.gov (United States)

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes.

  20. CTOD-based acceptance criteria for heat exchanger head staybolts

    International Nuclear Information System (INIS)

    Lam, P.S.; Sindelar, R.L.; Barnes, D.M.; Awadalla, N.G.

    1992-01-01

    The primary coolant piping system of the Savannah River Site (SRS) reactors contains twelve heat exchangers to remove the waste heat from the nuclear materials production. A large break at the inlet or outlet heads of the heat exchangers would occur if the restraint members of the heads become inactive. The heat exchanger head is attached to the tubesheet by 84 staybolts. The structural integrity of the heads is demonstrated by showing the redundant capacity of the staybolts to restrain the head at design conditions and under seismic loadings. The beat exchanger head is analyzed with a three- dimensional finite element model. The restraint provided by the staybolts is evaluated for several postulated cases of inactive or missing staybolts, that is, bolts that have a flaw exceeding the ultrasonic testing (UT) threshold depth of 25% of the bolt diameter. A limit of 6 inactive staybolts is reached with a fracture criterion based on the maximum allowable local displacement at the active staybolts which corresponds to the crack tip opening displacement (CTOD) of 0.032 inches. An acceptance criteria methodology has been developed to disposition flaws reported in the staybolt inspections while ensuring adequate restraint capacity of the staybolts to maintain integrity of the heat exchanger heads against collapse. The methodology includes an approach for the baseline and periodic inspections of the staybolts. A total of up to 6 staybolts, reported as containing flaws with depths at or exceeding 25% would be acceptable in the heat exchanger

  1. Integrated pressure sensor systems in the cylinder-head gasket; Integrierte Drucksensorik in der Zylinderkopfdichtung

    Energy Technology Data Exchange (ETDEWEB)

    Diez, A.; Maier, U. [ElringKlinger AG (Germany); Eifler, G. [ElringKlinger Motortechnik GmbH (Germany); Schnepf, M. [Kistler Instrumente AG, Winterthur (Switzerland)

    2004-01-01

    The optimisation of engine management plays a major role in the development of modern engines. A significant contribution to this optimisation will be made by a cylinder-head gasket with integrated pressure sensors of the quality required to measure in-cylinder pressure, which ElringKlinger AG together with Kistler Instrumente AG are currently working on. The goal is to provide the automotive industry with a system that makes it possible to optimally control combustion in each individual cylinder. (orig.) [German] Die Optimierung des Motormanagements spielt bei der Entwicklung moderner Motoren eine zentrale Rolle. Eine Zylinderkopfdichtung mit integrierten Druckaufnehmern in Indizierqualitaet, an der die Elring-Klinger AG und die Kistler Instrumente AG derzeit gemeinsam arbeiten, soll hierzu einen entscheidenden Beitrag leisten. Ziel ist es, der Automobilindustrie ein System zur Verfuegung zu stellen, das eine optimierte und zylinderindividuelle Steuerung der Verbrennung ermoeglicht. (orig.)

  2. Heading Estimation of Robot Combine Harvesters during Turning Maneuveres.

    Science.gov (United States)

    Rahman, Md Mostafizar; Ishii, Kazunobu

    2018-05-01

    Absolute heading is an important parameter for a robot combine harvester or a robot tracked combine harvester, especially while it is turning, but due to the rapid turning of robot combine harvesters, its inertial measurement unit gives a gyro measurement bias that causes heading drift. Our research goal is to estimate the absolute heading of robot combine harvesters by compensating this gyro measurement bias during non-linear turning maneuvers. A sensor fusion method like the extended Kalman filter combined with the tracked combine harvester dynamic model and sensor measurements was used to estimate the absolute heading of a robot combine harvester. Circular, sinusoidal and concave shapes were used to evaluate the estimated heading produced by the sensor fusion method. The results indicate that the estimated heading is better than measured heading which was calculated from the integration of yaw rate gyro measurements, and the root mean square errors (RMSEs) for estimated headings are smaller than the measured headings. In practics, the target of this paper is thus the estimation of a heading or absolute heading that is bias compensated, and can be further used to calculate the exact crop periphery for automatic path planning of robot combine harvesters.

  3. A prototype for a mammographic head and related developments

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L

    2004-02-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni.

  4. A prototype for a mammographic head and related developments

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L.

    2004-01-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni

  5. AR goggles make crime scene investigation a desk job

    OpenAIRE

    Aron, Jacob; NORTHFIELD, Dean

    2012-01-01

    CRIME scene investigators could one day help solve murders without leaving the office. A pair of augmented reality glasses could allow local police to virtually tag objects in a crime scene, and build a clean record of the scene in 3D video before evidence is removed for processing.\\ud The system, being developed by Oytun Akman and colleagues at the Delft University of Technology in the Netherlands, consists of a head-mounted display receiving 3D video from a pair of attached cameras controll...

  6. Added value of integrated circuit detector in head CT: objective and subjective image quality in comparison to conventional detector design.

    Science.gov (United States)

    Korn, Andreas; Bender, Benjamin; Spira, Daniel; Schabel, Christoph; Bhadelia, Rafeeque; Claussen, Claus; Ernemann, Ulrike; Brodoefel, Harald

    2014-12-01

    A new computed tomography (CT) detector with integrated electric components and shorter conducting pathways has recently been introduced to decrease system inherent electronic noise. The purpose of this study was to assess the potential benefit of such integrated circuit detector (ICD) in head CT by comparing objective and subjective image quality in low-dose examinations with a conventional detector design. Using a conventional detector, reduced-dose noncontrast head CT (255 mAs; effective dose, 1.7 mSv) was performed in 25 consecutive patients. Following transition to ICD, 25 consecutive patients were scanned using identical imaging parameters. Images in both groups were reconstructed with iterative reconstruction (IR) and filtered back projection (FBP) and assessed in terms of quantitative and qualitative image quality. Acquisition of head CT using ICD increased signal-to-noise ratio of gray and white matter by 14% (10.0 ± 1.6 vs. 11.4 ± 2.5; P = .02) and 17% (8.2 ± 0.8 vs. 9.6 ± 1.5; P = .000). The associated improvement in contrast-to-noise ratio was 12% (2.0 ± 0.5 vs. 2.2 ± 0.6; P = .121). In addition, there was a 51% increase in objective image sharpness (582 ± 85 vs. 884.5 ± 191; change in HU/Pixel; P < .000). Compared to standard acquisitions, subjective grading of noise and overall image quality scores were significantly improved with ICD (2.1 ± 0.3 vs. 1.6 ± 0.3; P < .000; 2.0 ± 0.5 vs. 1.6 ± 0.3; P = .001). Moreover, streak artifacts in the posterior fossa were substantially reduced (2.3 ± 0.7 vs. 1.7 ± 0.5; P = .004). At the same radiation level, acquisition of head CT with ICD achieves superior objective and subjective image quality and provides potential for significant dose reduction. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  7. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  8. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Keall, Paul J.; Wu Qiuwen; Williamson, Jeffrey F.; Schmidt-Ullrich, Rupert K.

    2005-01-01

    Purpose: The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. Methods and Materials: Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errors of σ = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with Σ = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for σ = Σ = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D 98 ), clinical target volume (CTV) D 90 , nodes D 90 , cord D 2 , and parotid D 50 and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. Results: Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error σ exceeded 3 mm. Simulated systematic setup errors with Σ = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a Σ = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error

  9. Objective Assessment of Activity Limitation in Glaucoma with Smartphone Virtual Reality Goggles: A Pilot Study.

    Science.gov (United States)

    Goh, Rachel L Z; Kong, Yu Xiang George; McAlinden, Colm; Liu, John; Crowston, Jonathan G; Skalicky, Simon E

    2018-01-01

    To evaluate the use of smartphone-based virtual reality to objectively assess activity limitation in glaucoma. Cross-sectional study of 93 patients (54 mild, 22 moderate, 17 severe glaucoma). Sociodemographics, visual parameters, Glaucoma Activity Limitation-9 and Visual Function Questionnaire - Utility Index (VFQ-UI) were collected. Mean age was 67.4 ± 13.2 years; 52.7% were male; 65.6% were driving. A smartphone placed inside virtual reality goggles was used to administer the Virtual Reality Glaucoma Visual Function Test (VR-GVFT) to participants, consisting of three parts: stationary, moving ball, driving. Rasch analysis and classical validity tests were conducted to assess performance of VR-GVFT. Twenty-four of 28 stationary test items showed acceptable fit to the Rasch model (person separation 3.02, targeting 0). Eleven of 12 moving ball test items showed acceptable fit (person separation 3.05, targeting 0). No driving test items showed acceptable fit. Stationary test person scores showed good criterion validity, differentiating between glaucoma severity groups ( P = 0.014); modest convergence validity, with mild to moderate correlation with VFQ-UI, better eye (BE) mean deviation, BE pattern deviation, BE central scotoma, worse eye (WE) visual acuity, and contrast sensitivity (CS) in both eyes ( R = 0.243-0.381); and suboptimal divergent validity. Multivariate analysis showed that lower WE CS ( P = 0.044) and greater age ( P = 0.009) were associated with worse stationary test person scores. Smartphone-based virtual reality may be a portable objective simulation test of activity limitation related to glaucomatous visual loss. The use of simulated virtual environments could help better understand the activity limitations that affect patients with glaucoma.

  10. Heading Estimation of Robot Combine Harvesters during Turning Maneuveres

    Directory of Open Access Journals (Sweden)

    Md Mostafizar Rahman

    2018-05-01

    Full Text Available Absolute heading is an important parameter for a robot combine harvester or a robot tracked combine harvester, especially while it is turning, but due to the rapid turning of robot combine harvesters, its inertial measurement unit gives a gyro measurement bias that causes heading drift. Our research goal is to estimate the absolute heading of robot combine harvesters by compensating this gyro measurement bias during non-linear turning maneuvers. A sensor fusion method like the extended Kalman filter combined with the tracked combine harvester dynamic model and sensor measurements was used to estimate the absolute heading of a robot combine harvester. Circular, sinusoidal and concave shapes were used to evaluate the estimated heading produced by the sensor fusion method. The results indicate that the estimated heading is better than measured heading which was calculated from the integration of yaw rate gyro measurements, and the root mean square errors (RMSEs for estimated headings are smaller than the measured headings. In practics, the target of this paper is thus the estimation of a heading or absolute heading that is bias compensated, and can be further used to calculate the exact crop periphery for automatic path planning of robot combine harvesters.

  11. Characterization of HPV and host genome interactions in primary head and neck cancers

    Science.gov (United States)

    Parfenov, Michael; Pedamallu, Chandra Sekhar; Gehlenborg, Nils; Freeman, Samuel S.; Danilova, Ludmila; Bristow, Christopher A.; Lee, Semin; Hadjipanayis, Angela G.; Ivanova, Elena V.; Wilkerson, Matthew D.; Protopopov, Alexei; Yang, Lixing; Seth, Sahil; Song, Xingzhi; Tang, Jiabin; Ren, Xiaojia; Zhang, Jianhua; Pantazi, Angeliki; Santoso, Netty; Xu, Andrew W.; Mahadeshwar, Harshad; Wheeler, David A.; Haddad, Robert I.; Jung, Joonil; Ojesina, Akinyemi I.; Issaeva, Natalia; Yarbrough, Wendell G.; Hayes, D. Neil; Grandis, Jennifer R.; El-Naggar, Adel K.; Meyerson, Matthew; Park, Peter J.; Chin, Lynda; Seidman, J. G.; Hammerman, Peter S.; Kucherlapati, Raju; Ally, Adrian; Balasundaram, Miruna; Birol, Inanc; Bowlby, Reanne; Butterfield, Yaron S.N.; Carlsen, Rebecca; Cheng, Dean; Chu, Andy; Dhalla, Noreen; Guin, Ranabir; Holt, Robert A.; Jones, Steven J.M.; Lee, Darlene; Li, Haiyan I.; Marra, Marco A.; Mayo, Michael; Moore, Richard A.; Mungall, Andrew J.; Robertson, A. Gordon; Schein, Jacqueline E.; Sipahimalani, Payal; Tam, Angela; Thiessen, Nina; Wong, Tina; Protopopov, Alexei; Santoso, Netty; Lee, Semin; Parfenov, Michael; Zhang, Jianhua; Mahadeshwar, Harshad S.; Tang, Jiabin; Ren, Xiaojia; Seth, Sahil; Haseley, Psalm; Zeng, Dong; Yang, Lixing; Xu, Andrew W.; Song, Xingzhi; Pantazi, Angeliki; Bristow, Christopher; Hadjipanayis, Angela; Seidman, Jonathan; Chin, Lynda; Park, Peter J.; Kucherlapati, Raju; Akbani, Rehan; Casasent, Tod; Liu, Wenbin; Lu, Yiling; Mills, Gordon; Motter, Thomas; Weinstein, John; Diao, Lixia; Wang, Jing; Fan, You Hong; Liu, Jinze; Wang, Kai; Auman, J. Todd; Balu, Saianand; Bodenheimer, Tom; Buda, Elizabeth; Hayes, D. Neil; Hoadley, Katherine A.; Hoyle, Alan P.; Jefferys, Stuart R.; Jones, Corbin D.; Kimes, Patrick K.; Marron, J.S.; Meng, Shaowu; Mieczkowski, Piotr A.; Mose, Lisle E.; Parker, Joel S.; Perou, Charles M.; Prins, Jan F.; Roach, Jeffrey; Shi, Yan; Simons, Janae V.; Singh, Darshan; Soloway, Mathew G.; Tan, Donghui; Veluvolu, Umadevi; Walter, Vonn; Waring, Scot; Wilkerson, Matthew D.; Wu, Junyuan; Zhao, Ni; Cherniack, Andrew D.; Hammerman, Peter S.; Tward, Aaron D.; Pedamallu, Chandra Sekhar; Saksena, Gordon; Jung, Joonil; Ojesina, Akinyemi I.; Carter, Scott L.; Zack, Travis I.; Schumacher, Steven E.; Beroukhim, Rameen; Freeman, Samuel S.; Meyerson, Matthew; Cho, Juok; Chin, Lynda; Getz, Gad; Noble, Michael S.; DiCara, Daniel; Zhang, Hailei; Heiman, David I.; Gehlenborg, Nils; Voet, Doug; Lin, Pei; Frazer, Scott; Stojanov, Petar; Liu, Yingchun; Zou, Lihua; Kim, Jaegil; Lawrence, Michael S.; Sougnez, Carrie; Lichtenstein, Lee; Cibulskis, Kristian; Lander, Eric; Gabriel, Stacey B.; Muzny, Donna; Doddapaneni, HarshaVardhan; Kovar, Christie; Reid, Jeff; Morton, Donna; Han, Yi; Hale, Walker; Chao, Hsu; Chang, Kyle; Drummond, Jennifer A.; Gibbs, Richard A.; Kakkar, Nipun; Wheeler, David; Xi, Liu; Ciriello, Giovanni; Ladanyi, Marc; Lee, William; Ramirez, Ricardo; Sander, Chris; Shen, Ronglai; Sinha, Rileen; Weinhold, Nils; Taylor, Barry S.; Aksoy, B. Arman; Dresdner, Gideon; Gao, Jianjiong; Gross, Benjamin; Jacobsen, Anders; Reva, Boris; Schultz, Nikolaus; Sumer, S. Onur; Sun, Yichao; Chan, Timothy; Morris, Luc; Stuart, Joshua; Benz, Stephen; Ng, Sam; Benz, Christopher; Yau, Christina; Baylin, Stephen B.; Cope, Leslie; Danilova, Ludmila; Herman, James G.; Bootwalla, Moiz; Maglinte, Dennis T.; Laird, Peter W.; Triche, Timothy; Weisenberger, Daniel J.; Van Den Berg, David J.; Agrawal, Nishant; Bishop, Justin; Boutros, Paul C.; Bruce, Jeff P; Byers, Lauren Averett; Califano, Joseph; Carey, Thomas E.; Chen, Zhong; Cheng, Hui; Chiosea, Simion I.; Cohen, Ezra; Diergaarde, Brenda; Egloff, Ann Marie; El-Naggar, Adel K.; Ferris, Robert L.; Frederick, Mitchell J.; Grandis, Jennifer R.; Guo, Yan; Haddad, Robert I.; Hammerman, Peter S.; Harris, Thomas; Hayes, D. Neil; Hui, Angela BY; Lee, J. Jack; Lippman, Scott M.; Liu, Fei-Fei; McHugh, Jonathan B.; Myers, Jeff; Ng, Patrick Kwok Shing; Perez-Ordonez, Bayardo; Pickering, Curtis R.; Prystowsky, Michael; Romkes, Marjorie; Saleh, Anthony D.; Sartor, Maureen A.; Seethala, Raja; Seiwert, Tanguy Y.; Si, Han; Tward, Aaron D.; Van Waes, Carter; Waggott, Daryl M.; Wiznerowicz, Maciej; Yarbrough, Wendell; Zhang, Jiexin; Zuo, Zhixiang; Burnett, Ken; Crain, Daniel; Gardner, Johanna; Lau, Kevin; Mallery, David; Morris, Scott; Paulauskis, Joseph; Penny, Robert; Shelton, Candance; Shelton, Troy; Sherman, Mark; Yena, Peggy; Black, Aaron D.; Bowen, Jay; Frick, Jessica; Gastier-Foster, Julie M.; Harper, Hollie A.; Lichtenberg, Tara M.; Ramirez, Nilsa C.; Wise, Lisa; Zmuda, Erik; Baboud, Julien; Jensen, Mark A.; Kahn, Ari B.; Pihl, Todd D.; Pot, David A.; Srinivasan, Deepak; Walton, Jessica S.; Wan, Yunhu; Burton, Robert; Davidsen, Tanja; Demchok, John A.; Eley, Greg; Ferguson, Martin L.; Shaw, Kenna R. Mills; Ozenberger, Bradley A.; Sheth, Margi; Sofia, Heidi J.; Tarnuzzer, Roy; Wang, Zhining; Yang, Liming; Zenklusen, Jean Claude; Saller, Charles; Tarvin, Katherine; Chen, Chu; Bollag, Roni; Weinberger, Paul; Golusiński, Wojciech; Golusiński, Paweł; Ibbs, Matthiew; Korski, Konstanty; Mackiewicz, Andrzej; Suchorska, Wiktoria; Szybiak, Bartosz; Wiznerowicz, Maciej; Burnett, Ken; Curley, Erin; Gardner, Johanna; Mallery, David; Penny, Robert; Shelton, Troy; Yena, Peggy; Beard, Christina; Mitchell, Colleen; Sandusky, George; Agrawal, Nishant; Ahn, Julie; Bishop, Justin; Califano, Joseph; Khan, Zubair; Bruce, Jeff P; Hui, Angela BY; Irish, Jonathan; Liu, Fei-Fei; Perez-Ordonez, Bayardo; Waldron, John; Boutros, Paul C.; Waggott, Daryl M.; Myers, Jeff; Lippman, Scott M.; Egea, Sophie; Gomez-Fernandez, Carmen; Herbert, Lynn; Bradford, Carol R.; Carey, Thomas E.; Chepeha, Douglas B.; Haddad, Andrea S.; Jones, Tamara R.; Komarck, Christine M.; Malakh, Mayya; McHugh, Jonathan B.; Moyer, Jeffrey S.; Nguyen, Ariane; Peterson, Lisa A.; Prince, Mark E.; Rozek, Laura S.; Sartor, Maureen A.; Taylor, Evan G.; Walline, Heather M.; Wolf, Gregory T.; Boice, Lori; Chera, Bhishamjit S.; Funkhouser, William K.; Gulley, Margaret L.; Hackman, Trevor G.; Hayes, D. Neil; Hayward, Michele C.; Huang, Mei; Rathmell, W. Kimryn; Salazar, Ashley H.; Shockley, William W.; Shores, Carol G.; Thorne, Leigh; Weissler, Mark C.; Wrenn, Sylvia; Zanation, Adam M.; Chiosea, Simion I.; Diergaarde, Brenda; Egloff, Ann Marie; Ferris, Robert L.; Romkes, Marjorie; Seethala, Raja; Brown, Brandee T.; Guo, Yan; Pham, Michelle; Yarbrough, Wendell G.

    2014-01-01

    Previous studies have established that a subset of head and neck tumors contains human papillomavirus (HPV) sequences and that HPV-driven head and neck cancers display distinct biological and clinical features. HPV is known to drive cancer by the actions of the E6 and E7 oncoproteins, but the molecular architecture of HPV infection and its interaction with the host genome in head and neck cancers have not been comprehensively described. We profiled a cohort of 279 head and neck cancers with next generation RNA and DNA sequencing and show that 35 (12.5%) tumors displayed evidence of high-risk HPV types 16, 33, or 35. Twenty-five cases had integration of the viral genome into one or more locations in the human genome with statistical enrichment for genic regions. Integrations had a marked impact on the human genome and were associated with alterations in DNA copy number, mRNA transcript abundance and splicing, and both inter- and intrachromosomal rearrangements. Many of these events involved genes with documented roles in cancer. Cancers with integrated vs. nonintegrated HPV displayed different patterns of DNA methylation and both human and viral gene expressions. Together, these data provide insight into the mechanisms by which HPV interacts with the human genome beyond expression of viral oncoproteins and suggest that specific integration events are an integral component of viral oncogenesis. PMID:25313082

  12. SU-E-T-166: Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient

    Energy Technology Data Exchange (ETDEWEB)

    Al-Basheer, A; Hunag, J; Kaminski, J; Dasher, B; Howington, J; Stewart, J; Martin, D; Kong, F; Jin, J [Georgia Regents University, Augusta, GA (Georgia)

    2014-06-01

    Purpose: Volumetric Modulated Arc Therapy (VMAT) usually achieves higher conformity of radiation doses to targets and less delivery time than Intensity Modulated Radiation Therapy (IMRT). We hypothesized that VMAT will increase integral dose (ID) to patients which will decrease the count of white blood count (WBC) lymphocytes, and consequently has a subsequent impact on the immune system. The purpose of this study is to evaluate the ID to patients undergoing IMRT and VMAT for Head and Neck cancers and its impact on the immune system. Methods: As a pilot study, 30 head and neck patients who received 9-fields IMRT or 3-arcs Radip-Arcbased VMAT were included in this study. Ten of these patients who received the VMAT plans were re-planned using IMRT with the same objectives. ID was calculated for all cases. All patients also had a baseline WBC obtained prior to treatment, and 3 sets of labs drawn during the course of radiation treatment. Results: For the 10 re-planned patients, the mean ID was 13.3 Gy/voxel (range 10.2–17.5 Gy/voxel) for the 9-fields IMRT plans, and was 15.9 Gy/voxel (range 12.4-20.9 Gy/voxel) for the 3-Arc VMAT plan (p=0.01). The integral dose was significant correlated with reducing WBC count during RT even when controlling for concurrent chemotherapy (R square =0.56, p=0.008). Conclusion: Although VMAT can deliver higher radiation dose conformality to targets, this benefit is achieved generally at the cost of greater integral doses to normal tissue outside the planning target volume (PTV). Lower WBC counts during RT were associated with higher Integral doses even when controlling for concurrent chemotherapy. This study is ongoing in our Institution to exam the impact of integral doses and WBC on overall survival.

  13. Visual perception of axes of head rotation

    Science.gov (United States)

    Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.

    2013-01-01

    Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is

  14. Visual perception of axes of head rotation

    Directory of Open Access Journals (Sweden)

    David Mattijs Arnoldussen

    2013-02-01

    Full Text Available Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. 1. Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit.We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow’s rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals.2. Do transformed visual self-rotation signals reflect the arrangement of the semicircular canals (SCC? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those BOLD signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes.3. We investigated if subject’s sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into

  15. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  16. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  17. HoloR: Interactive Mixed-Reality Rooms

    OpenAIRE

    Schwede, Carsten; Hermann, Thomas

    2015-01-01

    Existing virtual reality technologies only cover certain areas of the mixed-reality spectrum: Augmented reality goggles are unable to provide immersion while head-mounted displays make it difficult to interact with the real world. In this paper we introduce HoloR - short for Holographic Room: A stereoscopic, multi-person, multi-viewer, spatial projected augmented reality system, which enables applications to fade between different parts of the mixed-reality spectrum. By using web-technologies...

  18. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) PET/MRI in patients with head and neck cancer. This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4±13.4 years) with histologically proven head and neck tumors were enrolled.Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared. Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron

  19. IMRT With Simultaneous Integrated Boost and Concurrent Chemotherapy for Locoregionally Advanced Squamous Cell Carcinoma of the Head and Neck

    Energy Technology Data Exchange (ETDEWEB)

    Montejo, Michael E.; Shrieve, Dennis C. [Department of Radiation Oncology, Huntsman Cancer Hospital, University of Utah, Salt Lake City, Utah (United States); Bentz, Brandon G.; Hunt, Jason P.; Buchman, Luke O. [Division of Otolaryngology-Head Neck Surgery, Department of Surgery, Huntsman Cancer Hospital, University of Utah, Salt Lake City, Utah (United States); Agarwal, Neeraj [Department of Internal Medicine, Oncology Division, Huntsman Cancer Hospital, University of Utah, Salt Lake City, Utah (United States); Hitchcock, Ying J., E-mail: ying.hitchcock@hci.utah.edu [Department of Radiation Oncology, Huntsman Cancer Hospital, University of Utah, Salt Lake City, Utah (United States)

    2011-12-01

    Purpose: To evaluate the efficacy and toxicity of accelerated radiotherapy with concurrent chemotherapy in advanced head-and-neck squamous cell carcinoma. Methods and Materials: Between April 2003 and May 2008, 43 consecutive patients with advanced head-and-neck squamous cell carcinoma received accelerated chemoradiation with concurrent cisplatin or cetuximab. The doses for intensity-modulated radiotherapy with simultaneous integrated boost were 67.5, 60.0, and 54 Gy in 30 daily fractions of 2.25, 2.0, and 1.8 Gy to the planning target volumes for gross disease, high-risk nodes, and low-risk nodes, respectively. Results: Of the patients, 90.7% completed chemoradiotherapy as prescribed. The median treatment duration was 43 days (range, 38-55 days). The complete response rate was 74.4%. With median follow-up of 36.7 months (range, 16.8-78.1 months) in living patients, the estimated 1-, 2-, and 5-year locoregional control, overall survival, and disease-free survival rates were 82%, 82%, and 82%; 73%, 65%, and 61%; and 73%, 73%, and 70%, respectively. One treatment-related death occurred from renal failure. Grade 3 mucositis and dermatitis occurred in 13 patients (30.2%) and 3 patients (6.9%), respectively. Grade 2 xerostomia occurred in 12 patients (27.9%). In patients with adequate follow-up, 82% were feeding tube free by 6 months after therapy; 13% remained feeding tube dependent at 1 year. Grade 3 soft-tissue fibrosis, esophageal stricture, osteoradionecrosis, and trismus occurred in 3 patients (6.9%), 5 patients (11.6%), 1 patient (2.3%), and 3 patients (6.9%), respectively. Conclusions: Our results show that intensity-modulated radiotherapy with simultaneous integrated boost with concurrent chemotherapy improved local and regional control. Acute and late toxicities were tolerable and acceptable. A prospective trial of this fractionation regimen is necessary for further assessment of its efficacy and toxicity compared with other approaches.

  20. IMRT With Simultaneous Integrated Boost and Concurrent Chemotherapy for Locoregionally Advanced Squamous Cell Carcinoma of the Head and Neck

    International Nuclear Information System (INIS)

    Montejo, Michael E.; Shrieve, Dennis C.; Bentz, Brandon G.; Hunt, Jason P.; Buchman, Luke O.; Agarwal, Neeraj; Hitchcock, Ying J.

    2011-01-01

    Purpose: To evaluate the efficacy and toxicity of accelerated radiotherapy with concurrent chemotherapy in advanced head-and-neck squamous cell carcinoma. Methods and Materials: Between April 2003 and May 2008, 43 consecutive patients with advanced head-and-neck squamous cell carcinoma received accelerated chemoradiation with concurrent cisplatin or cetuximab. The doses for intensity-modulated radiotherapy with simultaneous integrated boost were 67.5, 60.0, and 54 Gy in 30 daily fractions of 2.25, 2.0, and 1.8 Gy to the planning target volumes for gross disease, high-risk nodes, and low-risk nodes, respectively. Results: Of the patients, 90.7% completed chemoradiotherapy as prescribed. The median treatment duration was 43 days (range, 38–55 days). The complete response rate was 74.4%. With median follow-up of 36.7 months (range, 16.8–78.1 months) in living patients, the estimated 1-, 2-, and 5-year locoregional control, overall survival, and disease-free survival rates were 82%, 82%, and 82%; 73%, 65%, and 61%; and 73%, 73%, and 70%, respectively. One treatment-related death occurred from renal failure. Grade 3 mucositis and dermatitis occurred in 13 patients (30.2%) and 3 patients (6.9%), respectively. Grade 2 xerostomia occurred in 12 patients (27.9%). In patients with adequate follow-up, 82% were feeding tube free by 6 months after therapy; 13% remained feeding tube dependent at 1 year. Grade 3 soft-tissue fibrosis, esophageal stricture, osteoradionecrosis, and trismus occurred in 3 patients (6.9%), 5 patients (11.6%), 1 patient (2.3%), and 3 patients (6.9%), respectively. Conclusions: Our results show that intensity-modulated radiotherapy with simultaneous integrated boost with concurrent chemotherapy improved local and regional control. Acute and late toxicities were tolerable and acceptable. A prospective trial of this fractionation regimen is necessary for further assessment of its efficacy and toxicity compared with other approaches.

  1. Pictorial essay: Vascular interventions in extra cranial head and neck

    OpenAIRE

    Suyash S Kulkarni; Nitin S Shetty; Tejas P Dharia; Ashwin M Polnaya

    2012-01-01

    Medicine is an ever changing field and interventional radiology (IR) procedures are becoming increasingly popular because of high efficacy and its minimally invasive nature of the procedure. Management of disease processes in the extra cranial head and neck (ECHN) has always been a challenge due to the complex anatomy of the region. Cross sectional imaging of the ECHN has grown and evolved tremendously and occupies a pivotal and integral position in the clinical management of variety of head ...

  2. Integrated sensors for robotic laser welding

    NARCIS (Netherlands)

    Iakovou, D.; Aarts, Ronald G.K.M.; Meijer, J.; Beyer, E.; Dausinger, F; Ostendorf, A; Otto, A.

    2005-01-01

    A welding head is under development with integrated sensory systems for robotic laser welding applications. Robotic laser welding requires sensory systems that are capable to accurately guide the welding head over a seam in three-dimensional space and provide information about the welding process as

  3. Quantifying the association between white matter integrity changes and subconcussive head impact exposure from a single season of youth and high school football using 3D convolutional neural networks

    Science.gov (United States)

    Saghafi, Behrouz; Murugesan, Gowtham; Davenport, Elizabeth; Wagner, Ben; Urban, Jillian; Kelley, Mireille; Jones, Derek; Powers, Alexander; Whitlow, Christopher; Stitzel, Joel; Maldjian, Joseph; Montillo, Albert

    2018-02-01

    The effect of subconcussive head impact exposure during contact sports, including American football, on brain health is poorly understood particularly in young and adolescent players, who may be more vulnerable to brain injury during periods of rapid brain maturation. This study aims to quantify the association between cumulative effects of head impact exposure from a single season of football on white matter (WM) integrity as measured with diffusion MRI. The study targets football players aged 9-18 years old. All players were imaged pre- and post-season with structural MRI and diffusion tensor MRI (DTI). Fractional Anisotropy (FA) maps, shown to be closely correlated with WM integrity, were computed for each subject, co-registered and subtracted to compute the change in FA per subject. Biomechanical metrics were collected at every practice and game using helmet mounted accelerometers. Each head impact was converted into a risk of concussion, and the risk of concussion-weighted cumulative exposure (RWE) was computed for each player for the season. Athletes with high and low RWE were selected for a two-category classification task. This task was addressed by developing a 3D Convolutional Neural Network (CNN) to automatically classify players into high and low impact exposure groups from the change in FA maps. Using the proposed model, high classification performance, including ROC Area Under Curve score of 85.71% and F1 score of 83.33% was achieved. This work adds to the growing body of evidence for the presence of detectable neuroimaging brain changes in white matter integrity from a single season of contact sports play, even in the absence of a clinically diagnosed concussion.

  4. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 2: Reactor pressure vessel embrittlement and thermal annealing; Reactor vessel lower head integrity; Evaluation and projection of steam generator tube condition and integrity

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1997-02-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This volume is divided into the following sections: reactor pressure vessel embrittlement and thermal annealing; reactor vessel lower head integrity; and evaluation and projection of steam generator tube condition and integrity. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  5. Proceedings of the twenty-fourth water reactor safety information meeting. Volume 2: Reactor pressure vessel embrittlement and thermal annealing; Reactor vessel lower head integrity; Evaluation and projection of steam generator tube condition and integrity

    International Nuclear Information System (INIS)

    Monteleone, S.

    1997-02-01

    This three-volume report contains papers presented at the Twenty-Fourth Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 21--23, 1996. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from Czech Republic, Finland, France, Japan, Norway, Russia and United Kingdom. This volume is divided into the following sections: reactor pressure vessel embrittlement and thermal annealing; reactor vessel lower head integrity; and evaluation and projection of steam generator tube condition and integrity. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  6. Analysis of real-time head accelerations in collegiate football players.

    Science.gov (United States)

    Duma, Stefan M; Manoogian, Sarah J; Bussone, William R; Brolinson, P Gunnar; Goforth, Mike W; Donnenwerth, Jesse J; Greenwald, Richard M; Chu, Jeffrey J; Crisco, Joseph J

    2005-01-01

    To measure and analyze head accelerations during American collegiate football practices and games. A newly developed in-helmet 6-accelerometer system that transmits data via radio frequency to a sideline receiver and laptop computer system was implemented. From the data transfer of these accelerometer traces, the sideline staff has real-time data including the head acceleration, the head injury criteria value, the severity index value, and the impact location. Data are presented for instrumented players for the entire 2003 football season, including practices and games. American collegiate football. Thirty-eight players from Virginia Tech's varsity football team. Accelerations and pathomechanics of head impacts. : A total of 3312 impacts were recorded over 35 practices and 10 games for 38 players. The average peak head acceleration, Gadd Severity Index, and Head Injury Criteria were 32 g +/- 25 g, 36 g +/- 91 g, and 26 g +/- 64 g, respectively. One concussive event was observed with a peak acceleration of 81 g, a 267 Gadd Severity Index, and 200 Head Injury Criteria. Because the concussion was not reported until the day after of the event, a retrospective diagnosis based on his history and clinical evaluation suggested a mild concussion. The primary finding of this study is that the helmet-mounted accelerometer system proved effective at collecting thousands of head impact events and providing contemporaneous head impact parameters that can be integrated with existing clinical evaluation techniques.

  7. Studies on core melt behaviour in a BWR pressure vessel lower head

    International Nuclear Information System (INIS)

    Lindholm, I.; Ikonen, K.; Hedberg, K.

    1999-01-01

    Core debris behaviour in the Nordic BWR lower head was investigated numerically using MELCOR and MAAP4 codes. Lower head failure due to penetration failure was studied with more detailed PASULA code taking thermal boundary conditions from MELCOR calculations. Creep rupture failure mode was examined with the two integral codes. Also, the possibility to prevent vessel failure by late reflooding was assessed in this study. (authors)

  8. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    Directory of Open Access Journals (Sweden)

    Dariusz Wroblewski

    2014-01-01

    Full Text Available Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1 manual, with patient response registered with a mouse click, and (2 visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1 minimal systematic differences between measurements taken in visual grasp and manual modes, (2 the average standard deviation of the difference distributions of about 5 dB, and (3 a systematic shift (of 4–6 dB to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients’ acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  9. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    Science.gov (United States)

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  10. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  11. Gender differences in head-neck segment dynamic stabilization during head acceleration.

    Science.gov (United States)

    Tierney, Ryan T; Sitler, Michael R; Swanik, C Buz; Swanik, Kathleen A; Higgins, Michael; Torg, Joseph

    2005-02-01

    Recent epidemiological research has revealed that gender differences exist in concussion incidence but no study has investigated why females may be at greater risk of concussion. Our purpose was to determine whether gender differences existed in head-neck segment kinematic and neuromuscular control variables responses to an external force application with and without neck muscle preactivation. Forty (20 females and 20 males) physically active volunteers participated in the study. The independent variables were gender, force application (known vs unknown), and force direction (forced flexion vs forced extension). The dependent variables were kinematic and EMG variables, head-neck segment stiffness, and head-neck segment flexor and extensor isometric strength. Statistical analyses consisted of multiple multivariate and univariate analyses of variance, follow-up univariate analyses of variance, and t-tests (P Gender differences existed in head-neck segment dynamic stabilization during head angular acceleration. Females exhibited significantly greater head-neck segment peak angular acceleration (50%) and displacement (39%) than males despite initiating muscle activity significantly earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity (79% peak activity and 117% muscle activity area). The head-neck segment angular acceleration differences may be because females exhibited significantly less isometric strength (49%), neck girth (30%), and head mass (43%), resulting in lower levels of head-neck segment stiffness (29%). For our subject demographic, the results revealed gender differences in head-neck segment dynamic stabilization during head acceleration in response to an external force application. Females exhibited significantly greater head-neck segment peak angular acceleration and displacement than males despite initiating muscle activity earlier (SCM only) and using a greater percentage of their maximum head-neck segment

  12. Proteome reference map of Drosophila melanogaster head.

    Science.gov (United States)

    Lee, Tian-Ren; Huang, Shun-Hong; Lee, Chi-Ching; Lee, Hsiao-Yun; Chan, Hsin-Tzu; Lin, Kuo-Sen; Chan, Hong-Lin; Lyu, Ping-Chiang

    2012-06-01

    Drosophila melanogaster has been used as a genetic model organism to understand the fundamental molecular mechanisms in human biology including memory formation that has been reported involving protein synthesis and/or post-translational modification. In this study, we employed a proteomic platform based on fluorescent 2DE and MALDI-TOF MS to build a standard D. melanogaster head proteome map for proteome-proteome comparison. In order to facilitate the comparison, an interactive database has been constructed for systematically integrating and analyzing the proteomes from different conditions and further implicated to study human diseases related to D. melanogaster model. In summary, the fundamental head proteomic database and bioinformatic analysis will be useful for further elucidating the biological mechanisms such as memory formation and neurodegenerative diseases. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. [Evaluation of visualization of biological stains with the use of alternative light source (ALS) for the purpose of genetic identification. Part I. Blood and saliva stains analysis].

    Science.gov (United States)

    Szeremeta, Michał; Pepiński, Witold; Niemcunowicz-Janica, Anna; Skawrońska, Małgorzata; Sackiewicz, Adam; Ptaszyńska-Sarosiek, Iwona; Okłota, Magdalena

    2010-01-01

    The objective of the investigation was evaluation of visualization of human blood and saliva stains with the use of alternative light source for the purpose of genetic identification. Experimental bloodstains on the bright base were the most clearly seen in the natural light and white light, up to blood dilution of 1:600. Complete typeability of AmpFISTR SGM Plus kit profiles was obtained from bloodstains at dilution 1:1500. Partial AmpFISTR SGM Plus kit profiles were typed from bloodstains at dilutions 1:1750 and 1:2000. Experimental saliva stains on the light-colored base were completely invisible in the natural light and white light, while they were visualized at wavelength range 300-415 nm through yellow goggles, and at wavelength range 300-455 nm through orange goggles at saliva dilution 1: 600. Complete typeability of AmpFISTR SGM Plus kit loci was obtained from saliva stains at dilution 1:1750. Partial AmpFISTR SGM Plus kit profiles were typed from saliva stains at dilution 1:2000. The wavelength of 455 nm and orange goggles were the optimal set for visualization of bloodstains on various, noncontrasting materials. Other useful wavelength/combinations of goggles were CSS light/red goggles. In case of saliva, the most useful general condition for visualization of stains on various, non-contrasting materials was with the wavelength set to 300-415 nm, while wearing yellow goggles. Other useful combinations of wavelength/goggles were 300-455 nm/orange or red goggles, and also CSS light/orange or red goggles.

  14. Spatial Updating Strategy Affects the Reference Frame in Path Integration.

    Science.gov (United States)

    He, Qiliang; McNamara, Timothy P

    2018-06-01

    This study investigated how spatial updating strategies affected the selection of reference frames in path integration. Participants walked an outbound path consisting of three successive waypoints in a featureless environment and then pointed to the first waypoint. We manipulated the alignment of participants' final heading at the end of the outbound path with their initial heading to examine the adopted reference frame. We assumed that the initial heading defined the principal reference direction in an allocentric reference frame. In Experiment 1, participants were instructed to use a configural updating strategy and to monitor the shape of the outbound path while they walked it. Pointing performance was best when the final heading was aligned with the initial heading, indicating the use of an allocentric reference frame. In Experiment 2, participants were instructed to use a continuous updating strategy and to keep track of the location of the first waypoint while walking the outbound path. Pointing performance was equivalent regardless of the alignment between the final and the initial headings, indicating the use of an egocentric reference frame. These results confirmed that people could employ different spatial updating strategies in path integration (Wiener, Berthoz, & Wolbers Experimental Brain Research 208(1) 61-71, 2011), and suggested that these strategies could affect the selection of the reference frame for path integration.

  15. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  16. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  17. A new optimization approach for nozzle selection and component allocation in multi-head beam-type SMD placement machines

    NARCIS (Netherlands)

    Torabi, S.A.; Hamedi, M.; Ashayeri, J.

    2013-01-01

    This paper addresses a highly challenging scheduling problem faced in multi-head beam-type surface mounting devices (SMD) machines. An integrated mathematical model is formulated aiming to balance workloads over multiple heads as well as improving the traveling speed of the robotic arm by

  18. Imaging of head and neck venous malformations

    International Nuclear Information System (INIS)

    Flis, Christine M.; Connor, Stephen E.

    2005-01-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team. (orig.)

  19. Three-Dimensional Facial Adaptation for MPEG-4 Talking Heads

    Directory of Open Access Journals (Sweden)

    Nikos Grammalidis

    2002-10-01

    Full Text Available This paper studies a new method for three-dimensional (3D facial model adaptation and its integration into a text-to-speech (TTS system. The 3D facial adaptation requires a set of two orthogonal views of the user′s face with a number of feature points located on both views. Based on the correspondences of the feature points′ positions, a generic face model is deformed nonrigidly treating every facial part as a separate entity. A cylindrical texture map is then built from the two image views. The generated head models are compared to corresponding models obtained by the commonly used adaptation method that utilizes 3D radial bases functions. The generated 3D models are integrated into a talking head system, which consists of two distinct parts: a multilingual text to speech sub-system and an MPEG-4 compliant facial animation sub-system. Support for the Greek language has been added, while preserving lip and speech synchronization.

  20. Human Papillomavirus Induced Transformation in Cervical and Head and Neck Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Allie K. [Cancer and Blood Diseases Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229 (United States); Wise-Draper, Trisha M. [Division of Hematology/Oncology, University of Cincinnati Medical Center, University of Cincinnati, Cincinnati, OH 45229 (United States); Wells, Susanne I., E-mail: Susanne.Wells@cchmc.org [Cancer and Blood Diseases Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229 (United States)

    2014-09-15

    Human papillomavirus (HPV) is one of the most widely publicized and researched pathogenic DNA viruses. For decades, HPV research has focused on transforming viral activities in cervical cancer. During the past 15 years, however, HPV has also emerged as a major etiological agent in cancers of the head and neck, in particular squamous cell carcinoma. Even with significant strides achieved towards the screening and treatment of cervical cancer, and preventive vaccines, cervical cancer remains the leading cause of cancer-associated deaths for women in developing countries. Furthermore, routine screens are not available for those at risk of head and neck cancer. The current expectation is that HPV vaccination will prevent not only cervical, but also head and neck cancers. In order to determine if previous cervical cancer models for HPV infection and transformation are directly applicable to head and neck cancer, clinical and molecular disease aspects must be carefully compared. In this review, we briefly discuss the cervical and head and neck cancer literature to highlight clinical and genomic commonalities. Differences in prognosis, staging and treatment, as well as comparisons of mutational profiles, viral integration patterns, and alterations in gene expression will be addressed.

  1. Human Papillomavirus Induced Transformation in Cervical and Head and Neck Cancers

    International Nuclear Information System (INIS)

    Adams, Allie K.; Wise-Draper, Trisha M.; Wells, Susanne I.

    2014-01-01

    Human papillomavirus (HPV) is one of the most widely publicized and researched pathogenic DNA viruses. For decades, HPV research has focused on transforming viral activities in cervical cancer. During the past 15 years, however, HPV has also emerged as a major etiological agent in cancers of the head and neck, in particular squamous cell carcinoma. Even with significant strides achieved towards the screening and treatment of cervical cancer, and preventive vaccines, cervical cancer remains the leading cause of cancer-associated deaths for women in developing countries. Furthermore, routine screens are not available for those at risk of head and neck cancer. The current expectation is that HPV vaccination will prevent not only cervical, but also head and neck cancers. In order to determine if previous cervical cancer models for HPV infection and transformation are directly applicable to head and neck cancer, clinical and molecular disease aspects must be carefully compared. In this review, we briefly discuss the cervical and head and neck cancer literature to highlight clinical and genomic commonalities. Differences in prognosis, staging and treatment, as well as comparisons of mutational profiles, viral integration patterns, and alterations in gene expression will be addressed

  2. What are Head Cavities? - A History of Studies on Vertebrate Head Segmentation.

    Science.gov (United States)

    Kuratani, Shigeru; Adachi, Noritaka

    2016-06-01

    Motivated by the discovery of segmental epithelial coeloms, or "head cavities," in elasmobranch embryos toward the end of the 19th century, the debate over the presence of mesodermal segments in the vertebrate head became a central problem in comparative embryology. The classical segmental view assumed only one type of metamerism in the vertebrate head, in which each metamere was thought to contain one head somite and one pharyngeal arch, innervated by a set of cranial nerves serially homologous to dorsal and ventral roots of spinal nerves. The non-segmental view, on the other hand, rejected the somite-like properties of head cavities. A series of small mesodermal cysts in early Torpedo embryos, which were thought to represent true somite homologs, provided a third possible view on the nature of the vertebrate head. Recent molecular developmental data have shed new light on the vertebrate head problem, explaining that head mesoderm evolved, not by the modification of rostral somites of an amphioxus-like ancestor, but through the polarization of unspecified paraxial mesoderm into head mesoderm anteriorly and trunk somites posteriorly.

  3. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  4. Investigation into the verification of the Synapsys videonystagmography (VNG) Ulmer calibration system.

    Science.gov (United States)

    Corless, Natalie; Goggins, Susannah

    2014-09-01

    To assess the accuracy and stability of the Synapsys VNG Ulmer calibration system when the goggles and infrared camera are repositioned, and the accuracy of the equipment's geometric calibration system. Prospective data collection involved participants conducting the system's horizontal calibration test. Eye measurements were then recorded for a 60° deviation (looking from 30° right to -30° left) and repeated after the goggles and infrared camera were removed/repositioned. Participants' eye measurements were also recorded after the geometric calibration had been activated. Twenty-two participants with no history of visual or vestibular pathology were recruited for this study. No significant differences were found when the goggles were removed and replaced (p = 0.21); when the infrared camera was repositioned within the goggles (p = 0.50); or when the goggles were removed and the camera repositioned (p = 0.18) after horizontal calibration. A significant difference was found during the assessment of geometric calibration (p < 0.01). Calibration is not affected by removal or repositioning of the goggles and/or infrared camera within the goggles, therefore suggesting recalibration may not be necessary. Caution should be exercised when using the equipment's geometric calibration and should only be used when the patient is unable to conduct the system's horizontal calibration test.

  5. SCDAP/RELAP5 modeling of movement of melted material through porous debris in lower head

    International Nuclear Information System (INIS)

    Siefken, L. J.; Harvego, E. A.

    2000-01-01

    A model is described for the movement of melted metallic material through a ceramic porous debris bed. The model is designed for the analysis of severe accidents in LWRs, wherein melted core plate material may slump onto the top of a porous bed of relocated core material supported by the lower head. The permeation of the melted core plate material into the porous debris bed influences the heatup of the debris bed and the heatup of the lower head supporting the debris. A model for mass transport of melted metallic material is applied that includes terms for viscosity and turbulence but neglects inertial and capillary terms because of their small value relative to gravity and viscous terms in the momentum equation. The relative permeability and passability of the porous debris are calculated as functions of debris porosity, particle size, and effective saturation. An iterative numerical solution is used to solve the set of nonlinear equations for mass transport. The effective thermal conductivity of the debris is calculated as a function of porosity, particle size, and saturation. The model integrates the equations for mass transport with a model for the two-dimensional conduction of heat through porous debris. The integrated model has been implemented into the SCDAP/RELAP5 code for the analysis of the integrity of LWR lower heads during severe accidents. The results of the model indicate that melted core plate material may permeate to near the bottom of a 1m deep hot porous debris bed supported by the lower head. The presence of the relocated core plate material was calculated to cause a 12% increase in the heat flux on the external surface of the lower head

  6. Epidemiology and Molecular Biology of Head and Neck Cancer.

    Science.gov (United States)

    Jou, Adriana; Hess, Jochen

    2017-01-01

    Head and neck cancer is a common and aggressive malignancy with a high morbidity and mortality profile. Although the large majority of cases resemble head and neck squamous cell carcinoma (HNSCC), the current classification based on anatomic site and tumor stage fails to capture the high level of biologic heterogeneity, and appropriate clinical management remains a major challenge. Hence, a better understanding of the molecular biology of HNSCC is urgently needed to support biomarker development and personalized care for patients. This review focuses on recent findings based on integrative genomics analysis and multi-scale modeling approaches and how they are beginning to provide more sophisticated clues as to the biological and clinical diversity of HNSCC. © 2017 S. Karger GmbH, Freiburg.

  7. Head injury: audit of a clinical guideline to justify head CT

    International Nuclear Information System (INIS)

    Haydon, Nicholas B.

    2013-01-01

    Head injury causes significant morbidity and mortality, and there is contention about which patients to scan. The UK National Health Service Clinical Guideline (CG) 56 provides criteria for selecting patients with clinically important brain injury who may benefit from a head CT scan, while minimising the radiation and economic burden of scanning patients without significant injury. This study aims to audit the documentation of the use of these guidelines in a busy UK trauma hospital and discusses the comparison with an Australian (New South Wales (NSW) ) head injury guideline. A retrospective cohort study of 480 patients presenting with head injury to the emergency department over 2 months was performed. The patient notes were assessed for documentation of each aspect of the clinical guidelines. Criteria were established to assess the utilisation of the CG 56. A database of clinical data was amalgamated with the head CT scan results for each patient. For the UK CG 56, 73% of the criteria were documented, with the least documented being 'signs of basal skull fracture' and 'amnesia of events'. Thirty-two per cent of patients received head CT and of these, 24% (37 patients) were reported to have pathology. Twenty-four patients underwent head CT without clinical justification being documented, none of which had reported pathology on CT. The study shows that the head injury guidelines are not being fully utilised at a major UK trauma hospital, resulting in 5% of patients being exposed to ionising radiation without apparent documented clinical justification. The NSW guideline has distinct differences to the CG 56, with a more complex algorithm and an absence of specific time frames for head CT completion. The results suggest a need for further education and awareness of head injury clinical guidelines.

  8. 78 FR 22848 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-04-17

    ... Spare Guidance Sections, 18 AN/AVS-9(V) Night Vision Goggles, H-764G with GEM V Selective Availability... Simulator (PASIS), 10 AMRAAM Spare Guidance Sections, 18 AN/AVS-9(V) Night Vision Goggles, H-764G with GEM V... other documentation up to Secret. 2. The AN/AVS-9 Night Vision Goggles (NVG) are 3rd generation aviation...

  9. Head Trauma: First Aid

    Science.gov (United States)

    First aid Head trauma: First aid Head trauma: First aid By Mayo Clinic Staff Most head trauma involves injuries that are minor and don't require ... 21, 2015 Original article: http://www.mayoclinic.org/first-aid/first-aid-head-trauma/basics/ART-20056626 . Mayo ...

  10. Head and neck cancer

    International Nuclear Information System (INIS)

    Vogl, S.E.

    1988-01-01

    This book contains 10 chapters. Some of the titles are: Combined Surgical Resection and Irradiation for Head and Neck Cancers; Analysis of Radiation Therapy Oncology Group Head and Neck Database: Identification of Prognostic Factors and the Re-evaluation of American Joint Committee Stages; Combined Modality Approach to Head and Neck Cancer; Induction Combination Chemotherapy of Regionally Advanced Head and Neck Cancer; and Outcome after Complete Remission to Induction Chemotherapy in Head and Neck Cancer

  11. Effect of head restraint backset on head-neck kinematics in whiplash.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2006-03-01

    Although head restraints were introduced in the 1960s as a countermeasure for whiplash, their limited effectiveness has been attributed to incorrect positioning. The effect of backset on cervical segmental angulations, which were previously correlated with spinal injury, has not been delineated. Therefore, the practical restraint position to minimize injury remains unclear. A parametric study of increasing head restraint backset between 0 and 140mm was conducted using a comprehensively validated computational model. Head retraction values increased with increasing backset, reaching a maximum value of 53.5mm for backsets greater than 60mm. Segmental angulation magnitudes, greatest at levels C5-C6 and C6-C7, reached maximum values during the retraction phase and increased with increasing backset. Results were compared to a previously published head restraint rating system, wherein lower cervical extension magnitudes from this study exceeded mean physiologic limits for restraint positions rated good, acceptable, marginal, and poor. As head restraint contact was the limiting factor in head retraction and segmental angulations, the present study indicates that minimizing whiplash injury may be accomplished by limiting head restraint backset to less than 60mm either passively or actively after impact.

  12. Contribution of Head Position, Standing Surface, and Vision to Postural Control in Community-Dwelling Older Adults.

    Science.gov (United States)

    Pociask, Fredrick D; DiZazzo-Miller, Rosanne; Goldberg, Allon; Adamo, Diane E

    2016-01-01

    Postural control requires the integration of sensorimotor information to maintain balance and to properly position and orient the body in response to external stimuli. Age-related declines in peripheral and central sensory and motor function contribute to postural instability and falls. This study investigated the contribution of head position, standing surface, and vision on postural sway in 26 community-dwelling older adults. Participants were asked to maintain a stable posture under conditions that varied standing surface, head position, and the availability of visual information. Significant main and interaction effects were found for all three factors. Findings from this study suggest that postural sway responses require the integration of available sources of sensory information. These results have important implications for fall risks in older adults and suggest that when standing with the head extended and eyes closed, older adults may place themselves at risk for postural disequilibrium and loss of balance. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  13. High Speed Solution of Spacecraft Trajectory Problems Using Taylor Series Integration

    Science.gov (United States)

    Scott, James R.; Martini, Michael C.

    2008-01-01

    Taylor series integration is implemented in a spacecraft trajectory analysis code-the Spacecraft N-body Analysis Program (SNAP) - and compared with the code s existing eighth-order Runge-Kutta Fehlberg time integration scheme. Nine trajectory problems, including near Earth, lunar, Mars and Europa missions, are analyzed. Head-to-head comparison at five different error tolerances shows that, on average, Taylor series is faster than Runge-Kutta Fehlberg by a factor of 15.8. Results further show that Taylor series has superior convergence properties. Taylor series integration proves that it can provide rapid, highly accurate solutions to spacecraft trajectory problems.

  14. Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

    International Nuclear Information System (INIS)

    Nishikido, F.; Obata, T.; Shimizu, K.; Suga, M.; Inadama, N.; Tachibana, A.; Yoshida, E.; Ito, H.; Yamaya, T.

    2014-01-01

    We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images. The prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu 1.8 Gd 0.2 SiO 5 :Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements. Energy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15–18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and

  15. Head and neck position sense.

    Science.gov (United States)

    Armstrong, Bridget; McNair, Peter; Taylor, Denise

    2008-01-01

    Traumatic minor cervical strains are common place in high-impact sports (e.g. tackling) and premature degenerative changes have been documented in sports people exposed to recurrent impact trauma (e.g. scrummaging in rugby) or repetitive forces (e.g. Formula 1 racing drivers, jockeys). While proprioceptive exercises have been an integral part of rehabilitation of injuries in the lower limb, they have not featured as prominently in the treatment of cervical injuries. However, head and neck position sense (HNPS) testing and re-training may have relevance in the management of minor sports-related neck injuries, and play a role in reducing the incidence of ongoing pain and problems with function. For efficacious programmes to be developed and tested, fundamental principles associated with proprioception in the cervical spine should be considered. Hence, this article highlights the importance of anatomical structures in the cervical spine responsible for position sense, and how their interaction with the CNS affects our ability to plan and execute effective purposeful movements. This article includes a review of studies examining position sense in subjects with and without pathology and describes the effects of rehabilitation programmes that have sought to improve position sense. In respect to the receptors providing proprioceptive information for the CNS, the high densities and complex arrays of spindles found in cervical muscles suggest that these receptors play a key role. There is some evidence suggesting that ensemble encoding of discharge patterns from muscle spindles is relayed to the CNS and that a pattern recognition system is used to establish joint position and movement. Sensory information from neck proprioceptive receptors is processed in tandem with information from the vestibular system. There are extensive anatomical connections between neck proprioceptive inputs and vestibular inputs. If positional information from the vestibular system is inaccurate or

  16. Application Of Reinforcement Learning In Heading Control Of A Fixed Wing UAV Using X-Plane Platform

    Directory of Open Access Journals (Sweden)

    Kimathi

    2017-02-01

    Full Text Available Heading control of an Unmanned Aerial Vehicle UAV is a vital operation of an autopilot system. It is executed by employing a design of control algorithms that control its direction and navigation. Most commonly available autopilots exploit Proportional-Integral-Derivative PID based heading controllers. In this paper we propose an online adaptive reinforcement learning heading controller. The autopilot heading controller will be designed in MatlabSimulink for controlling a UAV in X-Plane test platform. Through this platform the performance of the controller is shown using real time simulations. The performance of this controller is compared to that of a PID controller. The results show that the proposed method performs better than a well tuned PID controller.

  17. Person-Independent Head Pose Estimation Using Biased Manifold Embedding

    Directory of Open Access Journals (Sweden)

    Sethuraman Panchanathan

    2008-02-01

    Full Text Available Head pose estimation has been an integral problem in the study of face recognition systems and human-computer interfaces, as part of biometric applications. A fine estimate of the head pose angle is necessary and useful for several face analysis applications. To determine the head pose, face images with varying pose angles can be considered to be lying on a smooth low-dimensional manifold in high-dimensional image feature space. However, when there are face images of multiple individuals with varying pose angles, manifold learning techniques often do not give accurate results. In this work, we propose a framework for a supervised form of manifold learning called Biased Manifold Embedding to obtain improved performance in head pose angle estimation. This framework goes beyond pose estimation, and can be applied to all regression applications. This framework, although formulated for a regression scenario, unifies other supervised approaches to manifold learning that have been proposed so far. Detailed studies of the proposed method are carried out on the FacePix database, which contains 181 face images each of 30 individuals with pose angle variations at a granularity of 1∘. Since biometric applications in the real world may not contain this level of granularity in training data, an analysis of the methodology is performed on sparsely sampled data to validate its effectiveness. We obtained up to 2∘ average pose angle estimation error in the results from our experiments, which matched the best results obtained for head pose estimation using related approaches.

  18. Averaging hydraulic head, pressure head, and gravitational head in subsurface hydrology, and implications for averaged fluxes, and hydraulic conductivity

    Directory of Open Access Journals (Sweden)

    G. H. de Rooij

    2009-07-01

    Full Text Available Current theories for water flow in porous media are valid for scales much smaller than those at which problem of public interest manifest themselves. This provides a drive for upscaled flow equations with their associated upscaled parameters. Upscaling is often achieved through volume averaging, but the solution to the resulting closure problem imposes severe restrictions to the flow conditions that limit the practical applicability. Here, the derivation of a closed expression of the effective hydraulic conductivity is forfeited to circumvent the closure problem. Thus, more limited but practical results can be derived. At the Representative Elementary Volume scale and larger scales, the gravitational potential and fluid pressure are treated as additive potentials. The necessary requirement that the superposition be maintained across scales is combined with conservation of energy during volume integration to establish consistent upscaling equations for the various heads. The power of these upscaling equations is demonstrated by the derivation of upscaled water content-matric head relationships and the resolution of an apparent paradox reported in the literature that is shown to have arisen from a violation of the superposition principle. Applying the upscaling procedure to Darcy's Law leads to the general definition of an upscaled hydraulic conductivity. By examining this definition in detail for porous media with different degrees of heterogeneity, a series of criteria is derived that must be satisfied for Darcy's Law to remain valid at a larger scale.

  19. Updates in Head and Neck Reconstruction.

    Science.gov (United States)

    Largo, Rene D; Garvey, Patrick B

    2018-02-01

    After reading this article, the participant should be able to: 1. Have a basic understanding of virtual planning, rapid prototype modeling, three-dimensional printing, and computer-assisted design and manufacture. 2. Understand the principles of combining virtual planning and vascular mapping. 3. Understand principles of flap choice and design in preoperative planning of free osteocutaneous flaps in mandible and midface reconstruction. 4. Discuss advantages and disadvantages of computer-assisted design and manufacture in reconstruction of advanced oncologic mandible and midface defects. Virtual planning and rapid prototype modeling are increasingly used in head and neck reconstruction with the aim of achieving superior surgical outcomes in functionally and aesthetically critical areas of the head and neck compared with conventional reconstruction. The reconstructive surgeon must be able to understand this rapidly-advancing technology, along with its advantages and disadvantages. There is no limit to the degree to which patient-specific data may be integrated into the virtual planning process. For example, vascular mapping can be incorporated into virtual planning of mandible or midface reconstruction. Representative mandible and midface cases are presented to illustrate the process of virtual planning. Although virtual planning has become helpful in head and neck reconstruction, its routine use may be limited by logistic challenges, increased acquisition costs, and limited flexibility for intraoperative modifications. Nevertheless, the authors believe that the superior functional and aesthetic results realized with virtual planning outweigh the limitations.

  20. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    Science.gov (United States)

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  1. Head Lice

    Science.gov (United States)

    ... nits. You should also use hot water to wash any bed linens, towels, and clothing recently worn by the person who had head lice. Vacuum anything that can’t be washed, such as the couch, carpets, your child’s car seat, and any stuffed animals. Because head lice ...

  2. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    International Nuclear Information System (INIS)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y.; Hibbard, Roberta A.; Hicks, Ralph A.

    2017-01-01

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  3. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Hibbard, Roberta A.; Hicks, Ralph A. [Indiana University School of Medicine, Department of Pediatrics, Section of Child Protection Programs, Indianapolis, IN (United States)

    2017-07-15

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  4. Non-invasive head fixation for external irradiation of tumors of the head and neck

    International Nuclear Information System (INIS)

    Bale, R.J.; Sweeney, R.; Nevinny, M.; Auer, T.; Bluhm, A.; Lukas, P.; Vogele, M.; Thumfart, W.F.

    1998-01-01

    Purpose: To fully utilize the technical capabilities of radiation diagnostics and planning, a precise and reproducible method of head fixation is a prerequisite. Method: We have adapted the Vogele-Bale-Hohner (VBH) head holder (Wellhoefer Dosimetrie, Schwarzenbruck, Germany), originally designed for frameless stereotactic operations, to the requirements of external beam radiotherapy. A precise and reproducible head fixation is attained by an individualized vacuum upper-dental cast which is connected over 2 hydraulic arms to an adjustable head- and rigid base-plate. Radiation field and patient alignment lasers are marked on a relocatable clear PVC localization box. Results: The possibility of craniocaudal adjustment of the head plate on the base plate allows the system to adapt to the actucal position of the patient on the raditherapy couch granting tensionless repositioning. The VBH head holder has proven itself to be a precise yet practicable method of head fixation. Duration of mouthpiece production and daily repositioning is comparable to that of the thermoplastic mask. Conclusion: The new head holder is in routine use at our hospital and quite suitable for external beam radiation of patients with tumors of the head and neck. (orig.) [de

  5. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  7. Current assessment of integrated content of long-lived radionuclides in soils of the head part of the East Ural Radioactive Trace

    International Nuclear Information System (INIS)

    Molchanova, I.; Mikhailovskaya, L.; Antonov, K.; Pozolotina, V.; Antonova, E.

    2014-01-01

    Based on the datasets obtained during investigations from 2003 to 2012, the spatial distributions of 90 Sr, 137 Cs, and 239,240 Pu content in the soils of the head part of the East Ural Radioactive Trace (EURT) were mapped using the geographic information system ArcGIS. Taking into account the presence of spatial autocorrelation and anisotropy in the source data, an ordinary kriging method was applied to interpolate values of radionuclide contamination density at unsampled places. Further geostatistical data analysis was performed to determine the basic parameters of spatial dependencies and to integrally assess the contamination by long-lived radionuclides in soils of the central, east peripheral, and west peripheral parts of the trace. This analysis was based on simplified geometric models (sector- and rectangle-shaped areas). The Monte Carlo method was used to quantitatively assess the uncertainty of the values for the integrated quantities resulting from the statistical errors of the source data approximation. - Highlights: • We investigated 102 soil samples in 2003–2012 at different distances from PA Mayak. • We mapped spatial distribution of 90 Sr, 137 Cs, and 239,240 Pu at this area by ArcGIS. • Integrated content based on sector- and rectangle-shaped models are similar. • The studied area clearly split into central, west, and east parts. • Radionuclide content of the central part is higher two orders than of west and east. - Capsule abstract: The spatial distribution of 90 Sr, 137 Cs, and 239,240 Pu at the EURT area by ArcGIS

  8. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  9. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  10. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  11. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  12. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players.

    Science.gov (United States)

    Stewart, Walter F; Kim, Namhee; Ifrah, Chloe; Sliwinski, Martin; Zimmerman, Molly E; Kim, Mimi; Lipton, Richard B; Lipton, Michael L

    2018-01-01

    Compared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost) in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS) symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP) test performance. Active adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire ("HeadCount-2w"), reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests) at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE) linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing. 308 players (78% male) completed 741 HeadCount-2w. Mean (median) heading/2-weeks was 50 (17) for men and 26 (7) for women. Heading was significantly associated with poorer performance on psychomotor speed ( p  impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms. Poorer NP test performance was consistently related to frequent heading during soccer practice and competition in the 2 weeks before testing. In contrast, unintentional head impacts incurred

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  14. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  15. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  16. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players

    Directory of Open Access Journals (Sweden)

    Walter F. Stewart

    2018-04-01

    Full Text Available ObjectiveCompared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP test performance.MethodActive adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire (“HeadCount-2w”, reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing.Results308 players (78% male completed 741 HeadCount-2w. Mean (median heading/2-weeks was 50 (17 for men and 26 (7 for women. Heading was significantly associated with poorer performance on psychomotor speed (p < 0.001 and attention (p = 0.02 tasks and was borderline significant with poorer performance on the working memory (p = 0.06 task. Unintentional head impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms

  17. Design of the PET–MR system for head imaging of the DREAM Project

    International Nuclear Information System (INIS)

    González, A.J.; Conde, P.; Hernández, L.; Herrero, V.; Moliner, L.; Monzó, J.M.; Orero, A.; Peiró, A.; Rodríguez-Álvarez, M.J.; Ros, A.; Sánchez, F.; Soriano, A.; Vidal, L.F.; Benlloch, J.M.

    2013-01-01

    In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems

  18. Pictorial essay: Vascular interventions in extra cranial head and neck

    Directory of Open Access Journals (Sweden)

    Suyash S Kulkarni

    2012-01-01

    Full Text Available Medicine is an ever changing field and interventional radiology (IR procedures are becoming increasingly popular because of high efficacy and its minimally invasive nature of the procedure. Management of disease processes in the extra cranial head and neck (ECHN has always been a challenge due to the complex anatomy of the region. Cross sectional imaging of the ECHN has grown and evolved tremendously and occupies a pivotal and integral position in the clinical management of variety of head and neck pathologies. Advances in angiographic technologies including flat panel detector systems, biplane, and 3-dimensional rotational angiography have consolidated and expanded the role of IR in the management of various ECHN pathologies. The ECHN is at cross roads between the origins of great vessels and the cerebral vasculature. Thorough knowledge of functional and technical aspects of neuroangiography is essential before embarking on head and neck vascular interventions. The vessels of the head and neck can be involved by infectious and inflammatory conditions, get irradiated during radiotherapy and injured due to trauma or iatrogenic cause. The ECHN is also a common site for various hypervascular neoplasms and vascular malformations, which can be treated with endovascular and percutaneous embolization. This pictorial essay provides a review of variety of ECHN pathologies which were managed by various IR procedures using different approaches.

  19. Medieval times' influencing figure Rhaze's approach to head injuries in Liber Almansoris.

    Science.gov (United States)

    Acıduman, Ahmet; Aşkit, Cağatay; Belen, Deniz

    2014-12-01

    To present the chapter "On wound of the head and fracture of the head bone" of Kitāb al-Manṣūrī / Liber Almansoris, which was one of the early works of Rhazes. Both Arabic (Süleymaniye Manuscript Library, Ayasofya collection, Nr. 3751 and Millet Library, Feyzullah Efendi collection, Nr. 1327) and the Latin (Basileae, 1544) texts of Kitāb al-Manṣūrī / Liber Almansoris were studied, and the 26th section of the 7th chapter, entitled "Fī al-shajja kasr al-'aẓm al-ra's / De plagis capitis et fractura cranei / On wound of the head and fracture of the head bone" was translated into English and English text created. Rhazes underlined removing bone fragments in depressed and separated fractures of cranium along with protection of the dura, but he did not describe any surgical technique in this chapter. Galen's contemplation for the care of the dura with its integrity and as well his proposal to remove the bone fragments for preventing the dura from injury were the golden standards at the time that Rhazes also followed in the treatment of skull fractures. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    Science.gov (United States)

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    medical history and careful physical examination, clinically important diseases including neoplasms and Paget's disease are observed in patients diagnosed with osteoarthritis prior to total hip arthroplasty. Histological examination plays an integral role in quality assurance in femoral head banking, and it also represents a possible early diagnostic test for bone and bone-marrow-related diseases in patients undergoing total hip arthroplasty.

  1. Modeling with finite element of the upper head spring; Modelizacion con elementos finitos del resorte del cabezal superior

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Cardador, J.; Cerrain Arranz, A.

    2013-07-01

    The objective of this work is the development of a model of finite element of the upper head spring so that it can be used as a tool in the design of the same. For this purpose, simulates the behavior to compression spring of the integrated head 17 x 17 using a numerical model and are validated with experimental results obtained in tests conducted by ENUSA. The validated model is a new tool to the spring design of the upper head whose use can extend both for the evaluation of current designs as for the evaluation of new modifications.

  2. Selective pathologies of the head and neck in children: a developmental perspective.

    Science.gov (United States)

    Ozolek, John A

    2009-09-01

    The range of pathology seen in the head and neck region is truly amazing and to a large extent probably mirrors the complex signaling pathways and careful orchestration of events that occurs between the primordial germ layers during the development of this region. As is true in general for the entire discipline of pediatric pathology, the head and neck pathology within this age group is as diverse and different as its adult counterpart. Cases that come across the pediatric head and neck surgical pathology bench are more heavily weighted toward developmental and congenital lesions such as branchial cleft anomalies, thyroglossal duct cysts, ectopias, heterotopias, choristomas, and primitive tumors. Many congenital "benign" lesions can cause significant morbidity and even mortality if they compress the airway or other vital structures. Exciting investigations into the molecular embryology of craniofacial development have begun to shed light on the pathogenesis of craniofacial developmental lesions and syndromes. Much more investigation is needed, however, to intertwine aberrations in the molecular ontogeny and development of the head and neck regions to the represented pathology. This review will integrate traditional morphologic embryology with some of the recent advances in the molecular pathways of head and neck development followed by a discussion of a variety of developmental lesions finishing with tumors presumed to be derived from pluripotent/progenitor cells and tumors that show anomalous or aborted development.

  3. GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    Krmasek, J.; Novosad, K.

    1981-01-01

    This article evaluates performance tests of the Soviet made GPK heading machine carried out in 4 coal mines in Czechoslovakia (Ostrava-Karvina region and Kladno mines). GPK works in coal seams and rocks with compression strength of 40 to 50 MPa. Dimensions of the tunnel are height 1.8 to 3.8 m and width 2.6 to 4.7 m, tunnel gradient plus to minus 10 degrees. GPK weighs 16 t, its conical shaped cutting head equipped with RKS-1 cutting tools is driven by an electric motor with 55 kW capacity. Undercarriage of the GPK, gathering-arm loader, hydraulic system, electric system and dust supression system (water spraying or pneumatic section) are characterized. Specifications of GPK heading machines are compared with PK-3r and F8 heading machines. Reliability, number of failures, dust level, noise, productivity depending on compression strength of rocks, heading rate in coal and in rocks, energy consumption, performance in inclined tunnels, and cutting tool wear are evaluated. Tests show that GPK can be used to drive tunnels in coal with rock constituting up to 50% of the tunnel crosscut, as long as rock compression strength does not exceed 50 MPa. In rocks characterized by higher compression strength cutting tool wear sharply increases. GPK is characterized by higher productivity than that of the PK-3r heading machine. Among the weak points of the GPK are: unsatisfactory reliability and excessive wear of its elements. (4 refs.) (In Czech)

  4. Representation of heading direction in far and near head space

    NARCIS (Netherlands)

    Poljac, E.; Berg, A.V. van den

    2003-01-01

    Manipulation of objects around the head requires an accurate and stable internal representation of their locations in space, also during movements such as that of the eye or head. For far space, the representation of visual stimuli for goal-directed arm movements relies on retinal updating, if eye

  5. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  6. Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical.

    Science.gov (United States)

    Migliaccio, Americo A; Schubert, Michael C; Clendaniel, Richard A; Carey, John P; Della Santina, Charles C; Minor, Lloyd B; Zee, David S

    2006-06-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) "impulses" about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30 degrees nose down, 15 degrees nose down, 0 degrees, 15 degrees nose up, 30 degrees nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 80 degrees /s, and peak-acceleration of approximately 1000 degrees /s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 150 degrees /s, and peak-acceleration of approximately 3000 degrees /s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 +/- 0.09), to the starting pitch head orientation (P rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR.

  7. A miniature shoe-mounted orientation determination system for accurate indoor heading and trajectory tracking.

    Science.gov (United States)

    Zhang, Shengzhi; Yu, Shuai; Liu, Chaojun; Liu, Sheng

    2016-06-01

    Tracking the position of pedestrian is urgently demanded when the most commonly used GPS (Global Position System) is unavailable. Benefited from the small size, low-power consumption, and relatively high reliability, micro-electro-mechanical system sensors are well suited for GPS-denied indoor pedestrian heading estimation. In this paper, a real-time miniature orientation determination system (MODS) was developed for indoor heading and trajectory tracking based on a novel dual-linear Kalman filter. The proposed filter precludes the impact of geomagnetic distortions on pitch and roll that the heading is subjected to. A robust calibration approach was designed to improve the accuracy of sensors measurements based on a unified sensor model. Online tests were performed on the MODS with an improved turntable. The results demonstrate that the average RMSE (root-mean-square error) of heading estimation is less than 1°. Indoor heading experiments were carried out with the MODS mounted on the shoe of pedestrian. Besides, we integrated the existing MODS into an indoor pedestrian dead reckoning application as an example of its utility in realistic actions. A human attitude-based walking model was developed to calculate the walking distance. Test results indicate that mean percentage error of indoor trajectory tracking achieves 2% of the total walking distance. This paper provides a feasible alternative for accurate indoor heading and trajectory tracking.

  8. Dynamic genome wide expression profiling of Drosophila head development reveals a novel role of Hunchback in retinal glia cell development and blood-brain barrier integrity.

    Directory of Open Access Journals (Sweden)

    Montserrat Torres-Oliva

    2018-01-01

    Full Text Available Drosophila melanogaster head development represents a valuable process to study the developmental control of various organs, such as the antennae, the dorsal ocelli and the compound eyes from a common precursor, the eye-antennal imaginal disc. While the gene regulatory network underlying compound eye development has been extensively studied, the key transcription factors regulating the formation of other head structures from the same imaginal disc are largely unknown. We obtained the developmental transcriptome of the eye-antennal discs covering late patterning processes at the late 2nd larval instar stage to the onset and progression of differentiation at the end of larval development. We revealed the expression profiles of all genes expressed during eye-antennal disc development and we determined temporally co-expressed genes by hierarchical clustering. Since co-expressed genes may be regulated by common transcriptional regulators, we combined our transcriptome dataset with publicly available ChIP-seq data to identify central transcription factors that co-regulate genes during head development. Besides the identification of already known and well-described transcription factors, we show that the transcription factor Hunchback (Hb regulates a significant number of genes that are expressed during late differentiation stages. We confirm that hb is expressed in two polyploid subperineurial glia cells (carpet cells and a thorough functional analysis shows that loss of Hb function results in a loss of carpet cells in the eye-antennal disc. Additionally, we provide for the first time functional data indicating that carpet cells are an integral part of the blood-brain barrier. Eventually, we combined our expression data with a de novo Hb motif search to reveal stage specific putative target genes of which we find a significant number indeed expressed in carpet cells.

  9. Dynamic genome wide expression profiling of Drosophila head development reveals a novel role of Hunchback in retinal glia cell development and blood-brain barrier integrity

    Science.gov (United States)

    Torres-Oliva, Montserrat; Schneider, Julia; Wiegleb, Gordon

    2018-01-01

    Drosophila melanogaster head development represents a valuable process to study the developmental control of various organs, such as the antennae, the dorsal ocelli and the compound eyes from a common precursor, the eye-antennal imaginal disc. While the gene regulatory network underlying compound eye development has been extensively studied, the key transcription factors regulating the formation of other head structures from the same imaginal disc are largely unknown. We obtained the developmental transcriptome of the eye-antennal discs covering late patterning processes at the late 2nd larval instar stage to the onset and progression of differentiation at the end of larval development. We revealed the expression profiles of all genes expressed during eye-antennal disc development and we determined temporally co-expressed genes by hierarchical clustering. Since co-expressed genes may be regulated by common transcriptional regulators, we combined our transcriptome dataset with publicly available ChIP-seq data to identify central transcription factors that co-regulate genes during head development. Besides the identification of already known and well-described transcription factors, we show that the transcription factor Hunchback (Hb) regulates a significant number of genes that are expressed during late differentiation stages. We confirm that hb is expressed in two polyploid subperineurial glia cells (carpet cells) and a thorough functional analysis shows that loss of Hb function results in a loss of carpet cells in the eye-antennal disc. Additionally, we provide for the first time functional data indicating that carpet cells are an integral part of the blood-brain barrier. Eventually, we combined our expression data with a de novo Hb motif search to reveal stage specific putative target genes of which we find a significant number indeed expressed in carpet cells. PMID:29360820

  10. Head trauma and CT with special reference to diagnosis of complications of head trauma

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitose

    1979-01-01

    Cases in which CT was useful for the diagnosis of complications of head trauma were reported. First, complications of head trauma were given an outline, and then, cases of protrusion of the brain, traumatic pneumocephalus, and cerebro-vascular disorders caused by head trauma were mentioned. (Tsunoda, M.)

  11. Exploding head syndrome.

    Science.gov (United States)

    Sharpless, Brian A

    2014-12-01

    Exploding head syndrome is characterized by the perception of abrupt, loud noises when going to sleep or waking up. They are usually painless, but associated with fear and distress. In spite of the fact that its characteristic symptomatology was first described approximately 150 y ago, exploding head syndrome has received relatively little empirical and clinical attention. Therefore, a comprehensive review of the scientific literature using Medline, PsycINFO, Google Scholar, and PubMed was undertaken. After first discussing the history, prevalence, and associated features, the available polysomnography data and five main etiological theories for exploding head syndrome are summarized. None of these theories has yet reached dominance in the field. Next, the various methods used to assess and treat exploding head syndrome are discussed, as well as the limited outcome data. Finally, recommendations for future measure construction, treatment options, and differential diagnosis are provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Impact of radiation protection means on the dose to the lens of the eye while handling radionuclides in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Bruchmann, Iris; Szermerski, Bastian; Geworski, Lilli [Medical School Hannover (Germany). Dept. for Radiation Protection and Medical Physics; Behrens, Rolf [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany)

    2016-07-01

    The human eye lens appears to be more radiosensitive than previously assumed. The reduction of the limit for the dose to the lens of the eye to 20 mSv per year has been passed in the current Euratom Directives (2013). Therefore, in this work the impact of laboratory glasses and X-ray protective goggles was investigated and reciprocal attenuation factors (i.e. transmission factors) for different nuclides (Tc-99m, I-131, Y-90, F-18 and Ga-68) were determined. The radionuclides in typical geometry (syringe, applicator) were positioned at a distance of 50 cm to the eyes of four Alderson-Head-Phantoms. Different dosemeters measuring H{sub p}(3) respective H{sub p}(0.07) were fixed to the eyes of the phantoms, either behind the glasses or without any protection means, respectively. The mean reciprocal attenuation factors were determined to be between unity for F-18 and I-131 using laboratory glasses (no attenuation effect) and < 0.01 for Y-90 using X-ray protective goggles. All other results were between these extremes. It has been shown, that prospective doses to the lens of the eye can be reduced significantly by using appropriate radiation protection means, especially for those dose-relevant beta radiation emitting nuclides such as Y-90.

  13. Hyperfractionated accelerated radiotherapy with concomitant integrated boost of 70-75 Gy in 5 weeks for advanced head and neck cancer. A phase I dose escalation study

    Energy Technology Data Exchange (ETDEWEB)

    Cvek, J.; Skacelikova, E.; Otahal, B.; Halamka, M.; Feltl, D. [University Hospital Ostrava (Czech Republic). Dept. of Oncology; Kubes, J. [University Hospital Bulovka, Prague (Czech Republic). Dept. of Radiation Oncology; Kominek, P. [University Hospital Ostrava (Czech Republic). Dept. of Otolaryngology

    2012-08-15

    Background and purpose: The present study was performed to evaluate the feasibility of a new, 5-week regimen of 70-75 Gy hyperfractionated accelerated radiotherapy with concomitant integrated boost (HARTCIB) for locally advanced, inoperable head and neck cancer. Methods and materials: A total of 39 patients with very advanced, stage IV nonmetastatic head and neck squamous cell carcinoma (median gross tumor volume 72 ml) were included in this phase I dose escalation study. A total of 50 fractions intensity-modulated radiotherapy (IMRT) were administered twice daily over 5 weeks. Prescribed total dose/dose per fraction for planning target volume (PTV{sub tumor}) were 70 Gy in 1.4 Gy fractions, 72.5 Gy in 1.45 Gy fractions, and 75 Gy in 1.5 Gy fractions for 10, 13, and 16 patients, respectively. Uninvolved lymphatic nodes (PTV{sub uninvolved}) were irradiated with 55 Gy in 1.1 Gy fractions using the concomitant integrated boost. Results: Acute toxicity was evaluated according to the RTOG/EORTC scale; the incidence of grade 3 mucositis was 51% in the oral cavity/pharynx and 0% in skin and the recovery time was {<=} 9 weeks for all patients. Late toxicity was evaluated in patients in complete remission according to the RTOG/EORTC scale. No grade 3/4 late toxicity was observed. The 1-year locoregional progression-free survival was 50% and overall survival was 55%. Conclusion: HARTCIB (75 Gy in 5 weeks) is feasible for patients deemed unsuitable for chemoradiation. Acute toxicity was lower than predicted from radiobiological models; duration of dysphagia and confluent mucositis were particularly short. Better conformity of radiotherapy allows the use of more intensive altered fractionation schedules compared with older studies. These results suggest that further dose escalation might be possible when highly conformal techniques (e.g., stereotactic radiotherapy) are used.

  14. The association of temporomandibular disorder pain with history of head and neck injury in adolescents.

    Science.gov (United States)

    Fischer, Dena J; Mueller, Beth A; Critchlow, Cathy W; LeResche, Linda

    2006-01-01

    To evaluate the risk of self-reported temporomandibular disorder (TMD) pain among adolescents in relation to previous head and/or neck injury. 3,101 enrollees (11 to 17 years of age) of a nonprofit integrated health-care system were interviewed by telephone. Two hundred four cases with self-reported TMD pain and 194 controls without self-reported TMD pain frequency-matched to the cases by age and gender completed standardized in-person interviews and physical examinations in which reports of previous head/neck injuries were recorded. Odds ratio (OR) estimates and 95% confidence intervals (CIs) of the relative risks of TMD pain associated with prior head and/or neck injuries were calculated using logistic regression. A greater proportion of subjects reporting TMD pain (36%) than controls (25%) had a history of head and/or neck injuries (OR = 1.8, 95% CI, 1.1-2.8). In a separate analysis, the presence of TMD based upon the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) was assessed in relation to prior head and/or neck injury. Cases reporting TMD pain and meeting the RDC/TMD criteria for myofascial pain and/or arthralgia or arthritis were 2.0 (CI, 1.0-3.8) times more likely to have had a prior head injury than were controls with neither self-reported nor RDC/TMD pain diagnoses. The results suggest a modest association of prior head injuries with both self-reported and clinically diagnosed TMD pain in adolescents.

  15. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  16. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2009-01-01

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  17. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E. [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia 5000 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Division of Medical Imaging, Women' s and Children' s Hospital, North Adelaide, South Australia 5006 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia)

    2009-09-15

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  18. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  19. Development of integral type forgings for steam generator of nuclear power plant

    International Nuclear Information System (INIS)

    Suzuki, Komei; Sato, Ikuo; Murai, Etsuo

    1992-01-01

    The use of integral type steel forgings for the construction of pressure vessel enhances the structural integrity of components and makes the fabrication of components and the execution of in-service inspection (ISI) easier than those fabrication from plate and casting materials. Such steel forgings have been realized for steam generator (SG) for nuclear power plant as follows : (1) Forged shell ring : change from welding fabrication of formed plates to forging ; (2) Forged conical shell ring : ditto ; (3) Forged head integral with nozzles (s) : (i) Primary head : change from casting to forging ; (ii) Secondary head : change from welding fabrication of formed plates to forging. These steel forgings have been realized by recent development in manufacturing technologies, such as steel making, forging processes and heat treatment which are vital to the quality of steel forgings. Some examples of recent typical high quality steel forgings developed by the Japan Steel Works, Ltd. (JSW) are introduced, and the main points of the manufacturing technique and the quality attained are also described. (author)

  20. Multi-head Watson-Crick automata

    OpenAIRE

    Chatterjee, Kingshuk; Ray, Kumar Sankar

    2015-01-01

    Inspired by multi-head finite automata and Watson-Crick automata in this paper, we introduce new structure namely multi-head Watson-Crick automata where we replace the single tape of multi-head finite automaton by a DNA double strand. The content of the second tape is determined using a complementarity relation similar to Watson-Crick complementarity relation. We establish the superiority of our model over multi-head finite automata and also show that both the deterministic and non-determinis...

  1. Head Worn Display System for Equivalent Visual Operations

    Science.gov (United States)

    Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob

    2009-01-01

    Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.

  2. Natural head position: An overview.

    Science.gov (United States)

    Meiyappan, N; Tamizharasi, S; Senthilkumar, K P; Janardhanan, K

    2015-08-01

    Cephalometrics has given us a different perspective of interpreting various skeletal problems in the dentofacial complex. Natural head position (NHP) is a reproducible, physiologically determined aspect of function. To determine NHP, a horizontal or vertical reference line outside the crania was used, but preference was given generally to the horizontal. Various intra and extracranial cephalometric horizontal reference planes have been used to formulate diagnosis and plan individualized treatment for an integrated correction of the malocclusion cephalometrics is constantly undergoing refinements in its techniques and analyses to improve the clinical applications. Even though various methods for establishing NHP have been proposed, still it remains a challenge to the clinicians to implement the concept of NHP thoroughly in all the stages of treatment because of practical difficulties in the clinical scenario.

  3. Development of a helmet-mounted PLZT thermal/flash protection system

    International Nuclear Information System (INIS)

    Harris, J.O. Jr.; Cutchen, J.T.; Pfoff, B.J.

    1976-01-01

    Sandia Laboratories is developing PLZT thermal/flash protective devices (TFPD's) goggles to prevent exposure and resultant eye damage from nuclear weapon detonations. The primary emphasis of the present program is to transfer technology and establish production capability for helmet-mounted PLZT/TFPD goggles for USAF flight crews, with a non-helmet-mounted configuration to follow. The first production units are anticipated in the fall of 1977. The operating principles of the PLZT/TFPD goggle device are briefly outlined, and the device configuration and operational characteristics are described

  4. 45 CFR 1308.21 - Parent participation and transition of children into Head Start and from Head Start to public...

    Science.gov (United States)

    2010-10-01

    ... into Head Start and from Head Start to public school. 1308.21 Section 1308.21 Public Welfare... AND HUMAN SERVICES THE ADMINISTRATION FOR CHILDREN, YOUTH AND FAMILIES, HEAD START PROGRAM HEAD START... Standards § 1308.21 Parent participation and transition of children into Head Start and from Head Start to...

  5. The equivalent square concept for the head scatter factor based on scatter from flattening filter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Siyong; Palta, Jatinder R.; Zhu, Timothy C. [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida (United States)

    1998-06-01

    The equivalent field relationship between square and circular fields for the head scatter factor was evaluated at the source plane. The method was based on integrating the head scatter parameter for projected shaped fields in the source plane and finding a field that produced the same ratio of head scatter to primary dose on the central axis. A value of {sigma}/R{approx_equal}0.9 was obtained, where {sigma} was one-half of the side length of the equivalent square and R was the radius of the circular field. The assumptions were that the equivalent field relationship for head scatter depends primarily on the characteristics of scatter from the flattening filter, and that the differential scatter-to-primary ratio of scatter from the flattening filter decreases linearly with the radius, within the physical radius of the flattening filter. Lam and co-workers showed empirically that the area-to-perimeter ratio formula, when applied to an equivalent square formula at the flattening filter plane, gave an accurate prediction of the head scatter factor. We have analytically investigated the validity of the area-to-perimeter ratio formula. Our results support the fact that the area-to-perimeter ratio formula can also be used as the equivalent field formula for head scatter at the source plane. The equivalent field relationships for wedge and tertiary collimator scatter were also evaluated. (author)

  6. The equivalent square concept for the head scatter factor based on scatter from flattening filter

    International Nuclear Information System (INIS)

    Kim, Siyong; Palta, Jatinder R.; Zhu, Timothy C.

    1998-01-01

    The equivalent field relationship between square and circular fields for the head scatter factor was evaluated at the source plane. The method was based on integrating the head scatter parameter for projected shaped fields in the source plane and finding a field that produced the same ratio of head scatter to primary dose on the central axis. A value of σ/R≅0.9 was obtained, where σ was one-half of the side length of the equivalent square and R was the radius of the circular field. The assumptions were that the equivalent field relationship for head scatter depends primarily on the characteristics of scatter from the flattening filter, and that the differential scatter-to-primary ratio of scatter from the flattening filter decreases linearly with the radius, within the physical radius of the flattening filter. Lam and co-workers showed empirically that the area-to-perimeter ratio formula, when applied to an equivalent square formula at the flattening filter plane, gave an accurate prediction of the head scatter factor. We have analytically investigated the validity of the area-to-perimeter ratio formula. Our results support the fact that the area-to-perimeter ratio formula can also be used as the equivalent field formula for head scatter at the source plane. The equivalent field relationships for wedge and tertiary collimator scatter were also evaluated. (author)

  7. Modeling heading and path perception from optic flow in the case of independently moving objects

    Science.gov (United States)

    Raudies, Florian; Neumann, Heiko

    2013-01-01

    Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMOs) in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE) in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion/deletion, expansion/contraction, acceleration/deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans' heading and path perception robust in the presence of such IMOs. PMID:23554589

  8. Modeling Heading and Path Perception from Optic Flow in the Case of Independently Moving Objects

    Directory of Open Access Journals (Sweden)

    Florian eRaudies

    2013-04-01

    Full Text Available Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMO in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion / deletion, expansion / contraction, acceleration / deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans’ heading and path perception robust in the presence of such IMOs.

  9. Novel Smart Glove Technology as a Biomechanical Monitoring Tool

    Directory of Open Access Journals (Sweden)

    Brendan O’FLYNN

    2015-10-01

    Full Text Available Developments in Virtual Reality (VR technology and its overall market have been occurring since the 1960s when Ivan Sutherland created the world’s first tracked head-mounted display (HMD – a goggle type head gear. In society today, consumers are expecting a more immersive experience and associated tools to bridge the cyber-physical divide. This paper presents the development of a next generation smart glove microsystem to facilitate Human Computer Interaction through the integration of sensors, processors and wireless technology. The objective of the glove is to measure the range of hand joint movements, in real time and empirically in a quantitative manner. This includes accurate measurement of flexion, extension, adduction and abduction of the metacarpophalangeal (MCP, Proximal interphalangeal (PIP and Distal interphalangeal (DIP joints of the fingers and thumb in degrees, together with thumb-index web space movement. This system enables full real-time monitoring of complex hand movements. Commercially available gloves are not fitted with sufficient sensors for full data capture, and require calibration for each glove wearer. Unlike these current state-of-the-art data gloves, the UU / Tyndall Inertial Measurement Unit (IMU glove uses a combination of novel stretchable substrate material and 9 degree of freedom (DOF inertial sensors in conjunction with complex data analytics to detect joint movement. Our novel IMU data glove requires minimal calibration and is therefore particularly suited to multiple application domains such as Human Computer interfacing, Virtual reality, the healthcare environment..

  10. Information architecture for a patient-specific dashboard in head and neck tumor boards.

    Science.gov (United States)

    Oeser, Alexander; Gaebel, Jan; Dietz, Andreas; Wiegand, Susanne; Oeltze-Jafra, Steffen

    2018-03-28

    Overcoming the flaws of current data management conditions in head and neck oncology could enable integrated information systems specifically tailored to the needs of medical experts in a tumor board meeting. Clinical dashboards are a promising method to assist various aspects of the decision-making process in such cognitively demanding scenarios. However, in order to provide extensive and intuitive assistance to the participating physicians, the design and development of such a system have to be user-centric. To accomplish this task, conceptual methods need to be performed prior to the technical development and integration stages. We have conducted a qualitative survey including eight clinical experts with different levels of expertise in the field of head and neck oncology. According to the principles of information architecture, the survey focused on the identification and causal interconnection of necessary metrics for information assessment in the tumor board. Based on the feedback by the clinical experts, we have constructed a detailed map of the required information items for a tumor board dashboard in head and neck oncology. Furthermore, we have identified three distinct groups of metrics (patient, disease and therapy metrics) as well as specific recommendations for their structural and graphical implementation. By using the information architecture, we were able to gather valuable feedback about the requirements and cognitive processes of the tumor board members. Those insights have helped us to develop a dashboard application that closely adapts to the specified needs and characteristics, and thus is primarily user-centric.

  11. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  12. Heading for a fall? Management of head injury in infants.

    LENUS (Irish Health Repository)

    Williamson, M

    2010-09-01

    Head injury is one of the commonest reasons for infants (< 1 year) to attend the Emergency Department (ED). Clinical management varies considerably and concern about non accidental injury results in a high admission rate in some hospitals. Information was obtained on 103 children under one year of age presenting to the ED with head injury in a prospective study. The average age was 6.7 months and 57% of patients were male. Twenty eight babies had skull x rays with 1 skull fracture diagnosed. None required CT brain scan. Ninety eight (94%) were discharged home from the ED. There were no unplanned returns, readmissions or adverse events. The incidence of traumatic brain injury in children under one year of age presenting with head injury is low and the majority can be safely discharged home.

  13. Anatomic and dosimetric changes in patients with head and neck cancer treated with an integrated MRI-tri-60Co teletherapy device.

    Science.gov (United States)

    Raghavan, Govind; Kishan, Amar U; Cao, Minsong; Chen, Allen M

    2016-11-01

    Prior studies have relied on CT to assess alterations in anatomy among patients undergoing radiation for head and neck cancer. We sought to determine the feasibility of using MRI-based image-guided radiotherapy to quantify these changes and to ascertain their potential dosimetric implications. 6 patients with head and neck cancer were treated with intensity-modulated radiotherapy (IMRT) on a novel tri- 60 Co teletherapy system equipped with a 0.35-T MRI (VR, ViewRay Incorporated, Oakwood Village, OH) to 66-70 Gy in 33 fractions (fx). Pre-treatment MRIs on Fx 1, 5, 10, 15, 20, 25, 30 and 33 were imported into a contouring interface, where the primary gross tumour volume (GTV) and parotid glands were delineated. The centre of mass (COM) shifts for these structures were assessed relative to Day 1. Dosimetric data were co-registered with the MRIs, and doses to the GTV and parotid glands were assessed. Primary GTVs decreased significantly over the course of IMRT (median % volume loss, 38.7%; range, 29.5-72.0%; p < 0.05) at a median rate of 1.2%/fx (range, 0.92-2.2%/fx). Both the ipsilateral and contralateral parotid glands experienced significant volume loss (p < 0.05, for all) and shifted medially during IMRT. Weight loss correlated significantly with parotid gland volume loss and medial COM shift (p < 0.05). Integrated on-board MRI can be used to accurately contour and analyze primary GTVs and parotid glands over the course of IMRT. COM shifts and significant volume reductions were observed, confirming the results of prior CT-based exercises. Advances in knowledge: The superior resolution of on-board MRI may facilitate online adaptive replanning in the future.

  14. Brush head composition, wear profile, and cleaning efficacy: an assessment of three electric brush heads using in vitro methods.

    Science.gov (United States)

    Kaiser, Eva; Meyners, Michael; Markgraf, Dirk; Stoerkel, Ulrich; von Koppenfels, Roxana; Adam, Ralf; Soukup, Martin; Wehrbein, Heinrich; Erbe, Christina

    2014-01-01

    The objective of this research was to evaluate a current store brand (SB) brush head for composition/physical characteristics, Wear Index (WI), and cleaning efficacy versus the previous SB brush head refill design (SB control) and the Oral-B Precision Clean brush head (positive control, PC). This research consisted of three parts: 1) Analytical analysis using Fourier Transform Infrared (FT-IR) spectrometry to evaluate the chemical composition of the current SB brush head bristles relative to the SB control. In addition, physical parameters such as bristle count and diameter were determined. 2) Wear Index (WI) investigation to determine the Wear Index scores of in vitro-aged brush heads at four weeks (one month) and 13 weeks (three months) by a trained investigator. To "age" the brush heads, a robot system was used as a new alternative in vitro method to simulate aging by consumer use. 3) Robot testing to determine the cleaning performance of in vitro-aged brush heads, comparing one month-aged current SB brush heads with the SB control (one and three months-aged) and the PC brush heads (three months-aged) in a standardized fashion. 1) FT-IR analysis revealed that the chemical composition of the current and control SB refill brush heads is identical. In terms of physical parameters, the current SB brush head has 12% more bristles and a slightly oval brush head compared to the round brush head of the SB control. 2) Wear Index analysis showed there was no difference in the one month-aged current SB brush head versus the one month-aged SB control (1.67 vs. 1.50, p = 0.65) or versus the three months-aged PC brush head (1.67 vs. 1.50, p = 0.65). The one month-aged current SB brush head demonstrated statistically significantly less wear than the three months-aged SB control (1.67 vs. 2.67, p = 0.01). 3) Analysis of cleaning efficacy shows that the one month-aged current SB brush head had improved cleaning performance over the one month-aged SB control brush head (p < 0

  15. Is Heading in Youth Soccer Dangerous Play?

    Science.gov (United States)

    O'Kane, John W

    2016-01-01

    Soccer is among the most popular youth sports with over 3 million youth players registered in the U.S. Soccer is unique in that players intentionally use their head to strike the ball, leading to concerns that heading could cause acute or chronic brain injury, especially in the immature brains of children. Pub Med search without date restriction was conducted in November 2014 and August 2015 using the terms soccer and concussion, heading and concussion, and youth soccer and concussion. 310 articles were identified and reviewed for applicable content specifically relating to youth athletes, heading, and/or acute or chronic brain injury from soccer. Soccer is a low-risk sport for catastrophic head injury, but concussions are relatively common and heading often plays a role. At all levels of play, concussions are more likely to occur in the act of heading than with other facets of the game. While concussion from heading the ball without other contact to the head appears rare in adult players, some data suggests children are more susceptible to concussion from heading primarily in game situations. Contributing factors include biomechanical forces, less developed technique, and the immature brain's susceptibility to injury. There is no evidence that heading in youth soccer causes any permanent brain injury and there is limited evidence that heading in youth soccer can cause concussion. A reasonable approach based on U.S. Youth Soccer recommendations is to teach heading after age 10 in controlled settings, and heading in games should be delayed until skill acquisition and physical maturity allow the youth player to head correctly with confidence.

  16. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  17. 77 FR 37879 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-06-25

    ... Detecting Sets, 26 M240H Machine Guns, and 26 AN/AVS-6 Night Vision Goggles. Also included are M206 infrared... Guns, and 26 AN/AVS-6 Night Vision Goggles. Also included are M206 infrared countermeasure flares, M211...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other ... aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  2. Shivering heat production and core cooling during head-in and head-out immersion in 17 degrees C water.

    Science.gov (United States)

    Pretorius, Thea; Cahill, Farrell; Kocay, Sheila; Giesbrecht, Gordon G

    2008-05-01

    Many cold-water scenarios cause the head to be partially or fully immersed (e.g., ship wreck survival, scuba diving, cold-water adventure swim racing, cold-water drowning, etc.). However, the specific effects of head cold exposure are minimally understood. This study isolated the effect of whole-head submersion in cold water on surface heat loss and body core cooling when the protective shivering mechanism was intact. Eight healthy men were studied in 17 degrees C water under four conditions: the body was either insulated or exposed, with the head either out of the water or completely submersed under the water within each insulated/exposed subcondition. Submersion of the head (7% of the body surface area) in the body-exposed condition increased total heat loss by 11% (P < 0.05). After 45 min, head-submersion increased core cooling by 343% in the body-insulated subcondition (head-out: 0.13 +/- 0.2 degree C, head-in: 0.47 +/- 0.3 degree C; P < 0.05) and by 56% in the body-exposed subcondition (head-out: 0.40 +/- 0.3 degree C and head-in: 0.73 +/- 0.6 degree C; P < 0.05). In both body-exposed and body-insulated subconditions, head submersion increased the rate of core cooling disproportionally more than the relative increase in total heat loss. This exaggerated core-cooling effect is consistent with a head cooling induced reduction of the thermal core, which could be stimulated by cooling of thermosensitive and/or trigeminal receptors in the scalp, neck, and face. These cooling effects of head submersion are not prevented by shivering heat production.

  3. A patient positioning system in head and neck irradiation

    International Nuclear Information System (INIS)

    Bormann, U.; Strauch, B.; Schmitt, G.

    1986-01-01

    A holding system is presented which allows a good, easy, and reproducable positioning of the patient in percutanous head and neck radiotherapy. The patients are lying comfortably on a neck support and are fixed in such a way that they are not able to turn in a lateral or longitudinal direction. The distance chin-jugulum can be easily determined by an integrated measuring tape. Due to the use of UV ink and UV lamps, the field marking of the patient's skin cannot be seen in the spectrum of visible light. (orig.) [de

  4. Pigeons (C. livia Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight

    Directory of Open Access Journals (Sweden)

    Ivo G. Ros

    2017-12-01

    Full Text Available Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades, and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.

  5. Stereotactic Body Radiotherapy for Head and Neck Tumors

    Science.gov (United States)

    2016-04-18

    Squamous Cell Carcinoma of the Head and Neck; Nasopharyngeal Carcinoma; Salivary Gland Cancer; Head and Neck Sarcoma; Paraganglioma of Head and Neck; Chordoma of Head and Neck; Chondrosarcoma of Head and Neck; Angiofibroma of Head and Neck

  6. Radiation heat transfer in a pressurized water reactor lower head filled with molten corium

    International Nuclear Information System (INIS)

    Šadek, Siniša; Grgić, Davor; Debrecin, Nenad

    2013-01-01

    Highlights: ► We develop radiation heat exchange model for a reactor pressure vessel lower head. ► Model is used during a late in-vessel phase of severe accidents. ► View factors are calculated automatically for a time-dependent enclosure. ► Model is included in the RELAP5/SCDAPSIM computer code. ► Inclusion of heat radiation causes faster heat-up rate of RPV lower head structures. - Abstract: Following a core melt, molten material may slump to the lower head of a reactor pressure vessel (RPV). In that case, some structures like lower parts of fuel elements and a core support plate would remain intact. Since the melt is at high temperature and there are no obstacles between the melt and the supporting plate, the plate is exposed to an intense radiation heating. The radiation heat exchange model of the lower head was developed and applied to a finite element code COUPLE which is a part of the detailed mechanistic code RELAP5/SCDAPSIM. The radiation enclosure consisted of three surfaces: the upper surface of the relocated material, the inner surface of the RPV wall above the relocated material and the lower surface of the core support plate. View factors were calculated for the enclosure geometry that is changing in time because of intermittent accumulation of molten material. The enclosure surfaces were covered by mesh of polygonal areas and view factors were calculated, for each pair of the element areas, by solving the definite integrals using the algorithms for adaptive integrations by means of Gaussian quadrature. Algebraic equations for radiosity and irradiation vectors were solved by LU decomposition and the radiation model was explicitly coupled with the heat conduction model. The results show that there is a possibility of the core support plate failure after being heated up due to radiation heat exchange with the melt.

  7. Protective head of sensors

    International Nuclear Information System (INIS)

    Liska, K.; Anton, P.

    1987-01-01

    The discovery concerns the protective heads of diagnostic assemblies of nuclear power plants for conductors of the sensors from the fuel and control parts of the said assemblies. A detailed description is presented of the design of the protective head which, as compared with the previous design, allows quick and simple assembly with reduced risk of damaging the sensors. The protective head may be used for diagnostic assemblies both in power and in research reactors and it will be used for WWER reactor assemblies. (A.K.). 3 figs

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  9. Modular reactor head shielding system

    International Nuclear Information System (INIS)

    Jacobson, E. B.

    1985-01-01

    An improved modular reactor head shielding system is provided that includes a frame which is removably assembled on a reactor head such that no structural or mechanical alteration of the head is required. The shielding system also includes hanging assemblies to mount flexible shielding pads on trolleys which can be moved along the frame. The assemblies allow individual pivoting movement of the pads. The pivoting movement along with the movement allowed by the trolleys provides ease of access to any point on the reactor head. The assemblies also facilitate safe and efficient mounting of the pads directly to and from storage containers such that workers have additional shielding throughout virtually the entire installation and removal process. The flexible shielding pads are designed to interleave with one another when assembled around the reactor head for substantially improved containment of radiation leakage

  10. Development of steel head joints with fiberglass sucker rod on the base of contact stresses investigation

    Energy Technology Data Exchange (ETDEWEB)

    Kopey, B.V.; Kopey, L.B. [Ivano-Frankivsk State Technical Oil and Gas University (Ukraine); Maksymuk, A.V.; Shcherbyna, N.M. [National Ukrainian Academy of Sciences (Ukraine)

    1998-12-31

    The methods of calculation of contact stresses during cylinder shell tube - steel bandage interaction are presented. Tymoshenko`s generalized theory of shells serves as a basis for investigating steel head to fiberglass sucker rod joint strength. This theory allows to consider mechanical performance of composite materials. The problem is reduced to solving Fredholm integral equation of second degree. The numeric analysis is performed. Several joints of composite body with steel head are proposed. The full-size sucker rod fatigue tests are performed to determine the fatigue limit under the bending and axial cyclic loads in the medium of oil well fluids. (orig.)

  11. HYDROïD humanoid robot head with perception and emotion capabilities :Modeling, Design and Experimental Results

    Directory of Open Access Journals (Sweden)

    Samer eAlfayad

    2016-04-01

    Full Text Available In the framework of the HYDROïD humanoid robot project, this paper describes the modeling and design of an electrically actuated head mechanism. Perception and emotion capabilities are considered in the design process. Since HYDROïD humanoid robot is hydraulically actuated, the choice of electrical actuation for the head mechanism addressed in this paper is justified. Considering perception and emotion capabilities leads to a total number of 15 degrees of freedom for the head mechanism which are split on four main sub-mechanisms: the neck, the mouth, the eyes and the eyebrows. Biological data and kinematics performances of human head are taken as inputs of the design process. A new solution of uncoupled eyes is developed to possibly address the master-slave process that links the human eyes as well as vergence capabilities. Modeling each sub-system is carried out in order to get equations of motion, their frequency responses and their transfer functions. The neck pitch rotation is given as a study example. Then, the head mechanism performances are presented through a comparison between model and experimental results validating the hardware capabilities. Finally, the head mechanism is integrated on the HYDROïD upper-body. An object tracking experiment coupled with emotional expressions is carried out to validate the synchronization of the eye rotations with the body motions.

  12. Multi-headed comparatives in Portuguese

    Directory of Open Access Journals (Sweden)

    Rui Marques

    2005-06-01

    Full Text Available This paper aims at offering a global picture of the subtype of comparative constructions known as ‘multi-headed comparatives’ (from the fact that they exhibit more than one comparative operator in semantic interdependence. As a prerequisite to the fulfilment of his goal, an attempt will be made to clarify the scope of the notion ‘comparative construction’ and to draw a general typology of such constructions. The boundaries of the notion ‘comparative construction’ are defined by contrasting a “genuine” class of comparative constructions with others that hold some syntactic or semantic resemblance to them. Different typologies will be taken into consideration. As for multi-headed comparatives, even though different examples of these constructions have been identified in the scarce literature on the matter, the discussion on their syntactic patterns and meaning is still embryonic. This paper suggests that the expressive power of these comparatives, which seem to provide a particular strategy of information compression, is higher than has been assumed. Four sub-kinds of multi-headed comparatives are identified, based on meaning differences, namely: multi-headed comparatives with a distributive reading, multi-headed comparatives with a cumulative reading, multi-headed comparatives with a comparison of ‘ratios’ reading, and multi-headed comparatives with a comparison of differences reading. While resorting to some classic English examples, the object language will predominantly be Portuguese.

  13. Validation and calibration of HeadCount, a self-report measure for quantifying heading exposure in soccer players.

    Science.gov (United States)

    Catenaccio, E; Caccese, J; Wakschlag, N; Fleysher, R; Kim, N; Kim, M; Buckley, T A; Stewart, W F; Lipton, R B; Kaminski, T; Lipton, M L

    2016-01-01

    The long-term effects of repetitive head impacts due to heading are an area of increasing concern, and exposure must be accurately measured; however, the validity of self-report of cumulative soccer heading is not known. In order to validate HeadCount, a 2-week recall questionnaire, the number of player-reported headers was compared to the number of headers observed by trained raters for a men's and a women's collegiate soccer teams during an entire season of competitive play using Spearman's correlations and intraclass correlation coefficients (ICCs), and calibrated using a generalized estimating equation. The average Spearman's rho was 0.85 for men and 0.79 for women. The average ICC was 0.75 in men and 0.38 in women. The calibration analysis demonstrated that men tend to report heading accurately while women tend to overestimate. HeadCount is a valid instrument for tracking heading behaviour, but may have to be calibrated in women.

  14. Merkel cell carcinoma of the head and neck: poorer prognosis than non-head and neck sites.

    Science.gov (United States)

    Morand, G B; Madana, J; Da Silva, S D; Hier, M P; Mlynarek, A M; Black, M J

    2016-04-01

    Merkel cell carcinoma is a rare, aggressive neurocutaneous malignancy. This study investigated whether patients with Merkel cell carcinoma in the head and neck had poorer outcomes than patients with Merkel cell carcinoma located elsewhere. A retrospective study was performed of patients with Merkel cell carcinoma treated at the Jewish General Hospital in Montréal, Canada, from 1993 to 2013. Associations between clinicopathological characteristics and disease-free and disease-specific survival rates were examined according to the Kaplan-Meier method. Twenty-seven patients were identified. Although basic clinicopathological characteristics and treatments were similar between head and neck and non-head and neck Merkel cell carcinoma groups, disease-free and disease-specific survival rates were significantly lower in the head and neck Merkel cell carcinoma group (log-rank test; p = 0.043 and p = 0.001, respectively). Mortality was mainly due to distant metastasis. Patients with head and neck Merkel cell carcinoma had poorer survival rates than patients with non-head and neck Merkel cell carcinoma in our study. The tendency to obtain close margins, a less predictable metastatic pattern, and/or intrinsic tumour factors related to the head and neck may explain this discrepancy.

  15. Very Low Head Turbine Deployment in Canada

    International Nuclear Information System (INIS)

    Kemp, P; Williams, C; Sasseville, Remi; Anderson, N

    2014-01-01

    The Very Low Head (VLH) turbine is a recent turbine technology developed in Europe for low head sites in the 1.4 - 4.2 m range. The VLH turbine is primarily targeted for installation at existing hydraulic structures to provide a low impact, low cost, yet highly efficient solution. Over 35 VLH turbines have been successfully installed in Europe and the first VLH deployment for North America is underway at Wasdell Falls in Ontario, Canada. Deployment opportunities abound in Canada with an estimated 80,000 existing structures within North America for possible low-head hydro development. There are several new considerations and challenges for the deployment of the VLH turbine technology in Canada in adapting to the hydraulic, environmental, electrical and social requirements. Several studies were completed to determine suitable approaches and design modifications to mitigate risk and confirm turbine performance. Diverse types of existing weirs and spillways pose certain hydraulic design challenges. Physical and numerical modelling of the VLH deployment alternatives provided for performance optimization. For this application, studies characterizing the influence of upstream obstacles using water tunnel model testing as well as full-scale prototype flow dynamics testing were completed. A Cold Climate Adaptation Package (CCA) was developed to allow year-round turbine operation in ice covered rivers. The CCA package facilitates turbine extraction and accommodates ice forces, frazil ice, ad-freezing and cold temperatures that are not present at the European sites. The Permanent Magnet Generator (PMG) presents some unique challenges in meeting Canadian utility interconnection requirements. Specific attention to the frequency driver control and protection requirements resulted in a driver design with greater over-voltage capability for the PMG as well as other key attributes. Environmental studies in Europe included fish friendliness testing comprised of multiple in

  16. Very Low Head Turbine Deployment in Canada

    Science.gov (United States)

    Kemp, P.; Williams, C.; Sasseville, Remi; Anderson, N.

    2014-03-01

    The Very Low Head (VLH) turbine is a recent turbine technology developed in Europe for low head sites in the 1.4 - 4.2 m range. The VLH turbine is primarily targeted for installation at existing hydraulic structures to provide a low impact, low cost, yet highly efficient solution. Over 35 VLH turbines have been successfully installed in Europe and the first VLH deployment for North America is underway at Wasdell Falls in Ontario, Canada. Deployment opportunities abound in Canada with an estimated 80,000 existing structures within North America for possible low-head hydro development. There are several new considerations and challenges for the deployment of the VLH turbine technology in Canada in adapting to the hydraulic, environmental, electrical and social requirements. Several studies were completed to determine suitable approaches and design modifications to mitigate risk and confirm turbine performance. Diverse types of existing weirs and spillways pose certain hydraulic design challenges. Physical and numerical modelling of the VLH deployment alternatives provided for performance optimization. For this application, studies characterizing the influence of upstream obstacles using water tunnel model testing as well as full-scale prototype flow dynamics testing were completed. A Cold Climate Adaptation Package (CCA) was developed to allow year-round turbine operation in ice covered rivers. The CCA package facilitates turbine extraction and accommodates ice forces, frazil ice, ad-freezing and cold temperatures that are not present at the European sites. The Permanent Magnet Generator (PMG) presents some unique challenges in meeting Canadian utility interconnection requirements. Specific attention to the frequency driver control and protection requirements resulted in a driver design with greater over-voltage capability for the PMG as well as other key attributes. Environmental studies in Europe included fish friendliness testing comprised of multiple in

  17. [Virtual audiovisual talking heads: articulatory data and models--applications].

    Science.gov (United States)

    Badin, P; Elisei, F; Bailly, G; Savariaux, C; Serrurier, A; Tarabalka, Y

    2007-01-01

    In the framework of experimental phonetics, our approach to the study of speech production is based on the measurement, the analysis and the modeling of orofacial articulators such as the jaw, the face and the lips, the tongue or the velum. Therefore, we present in this article experimental techniques that allow characterising the shape and movement of speech articulators (static and dynamic MRI, computed tomodensitometry, electromagnetic articulography, video recording). We then describe the linear models of the various organs that we can elaborate from speaker-specific articulatory data. We show that these models, that exhibit a good geometrical resolution, can be controlled from articulatory data with a good temporal resolution and can thus permit the reconstruction of high quality animation of the articulators. These models, that we have integrated in a virtual talking head, can produce augmented audiovisual speech. In this framework, we have assessed the natural tongue reading capabilities of human subjects by means of audiovisual perception tests. We conclude by suggesting a number of other applications of talking heads.

  18. AHP 47: YELLOW-HEAD HORSE

    Directory of Open Access Journals (Sweden)

    Sangs rgyas bkra shis སངས་རྒྱས་བཀྲ་ཤིས།

    2017-04-01

    Full Text Available My family had a stallion we called Rta mgo ser 'Yellow-Head Horse'. Father and two of his brothers occasionally rode it. Father said that Yellow-Head was very wild when it was taken to join local horseraces. I didn't believe that because Yellow-Head was very gentle when Mother rode it to the local monastery and also when I rode it.

  19. Systematic biases in human heading estimation.

    Directory of Open Access Journals (Sweden)

    Luigi F Cuturi

    Full Text Available Heading estimation is vital to everyday navigation and locomotion. Despite extensive behavioral and physiological research on both visual and vestibular heading estimation over more than two decades, the accuracy of heading estimation has not yet been systematically evaluated. Therefore human visual and vestibular heading estimation was assessed in the horizontal plane using a motion platform and stereo visual display. Heading angle was overestimated during forward movements and underestimated during backward movements in response to both visual and vestibular stimuli, indicating an overall multimodal bias toward lateral directions. Lateral biases are consistent with the overrepresentation of lateral preferred directions observed in neural populations that carry visual and vestibular heading information, including MSTd and otolith afferent populations. Due to this overrepresentation, population vector decoding yields patterns of bias remarkably similar to those observed behaviorally. Lateral biases are inconsistent with standard bayesian accounts which predict that estimates should be biased toward the most common straight forward heading direction. Nevertheless, lateral biases may be functionally relevant. They effectively constitute a perceptual scale expansion around straight ahead which could allow for more precise estimation and provide a high gain feedback signal to facilitate maintenance of straight-forward heading during everyday navigation and locomotion.

  20. Shortened outage duration and increased safety with head assembly upgrade packages

    International Nuclear Information System (INIS)

    Leanne, M.; Lisien, P.E.; Plute, K.; Duran, J.

    2007-01-01

    To significantly reduce outage critical path duration and personnel radiation exposure, and to increase personnel safety, Westinghouse Electric Co., LLC has designed and installed upgrades to the existing head assemblies of operating pressurized water reactors. These upgrades are known as Head Assembly Upgrade Packages (HAUPs) or Simplified Head Assemblies (SHAs). Custom configurations are created from a set of standard elements to optimize the design for each unique containment, head assembly configuration, and licensing basis. Two primary options are available for implementation: a full HAUP or targeted component and system upgrades. Plants may achieve much of the outage savings, dose reduction, and safety improvements even with a more limited hardware scope. A range of improvements can be offered from integral missile shields, to redesigned duct work, radiation shields, and cable layout and connection optimization. The hardware changes are customized to target the scope that adds the most value for a given plant. While combining upgrades with a reactor vessel head (RVH) replacement adds some flexibility, it is not necessary. Some plants have chosen to implement targeted upgrades prior to a replacement RVH outage and then complete the remainder of the full HAUP during the replacement RVH outage. Three-dimensional computer aided design tools are used in the conceptual and detailed design phases to identify and avoid interferences between existing and replacement plant components. State-of-the-art computational fluid dynamics models for control drive mechanism (CDM) cooling systems are used to demonstrate the ability to maintain or improve the original design performance while greatly simplifying the disassembly/re-assembly activities. Likewise, state-of-the-art finite element analysis methods allow optimization of structural components while meeting code limits for design basis accident conditions. (authors)

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  2. Profitability of Integrated Management of Fusarium Head Blight in North Carolina Winter Wheat.

    Science.gov (United States)

    Cowger, Christina; Weisz, Randy; Arellano, Consuelo; Murphy, Paul

    2016-08-01

    Fusarium head blight (FHB) is one of the most difficult small-grain diseases to manage, due to the partial effectiveness of management techniques and the narrow window of time in which to apply fungicides profitably. The most effective management approach is to integrate cultivar resistance with FHB-specific fungicide applications; yet, when forecasted risk is intermediate, it is often unclear whether such an application will be profitable. To model the profitability of FHB management under varying conditions, we conducted a 2-year split-plot field experiment having as main plots high-yielding soft red winter wheat cultivars, four moderately resistant (MR) and three susceptible (S) to FHB. Subplots were sprayed at flowering with Prosaro or Caramba, or left untreated. The experiment was planted in seven North Carolina environments (location-year combinations); three were irrigated to promote FHB development and four were not irrigated. Response variables were yield, test weight, disease incidence, disease severity, deoxynivalenol (DON), Fusarium-damaged kernels, and percent infected kernels. Partial profits were compared in two ways: first, across low-, medium-, or high-DON environments; and second, across environment-cultivar combinations divided by risk forecast into "do spray" and "do not spray" categories. After surveying DON and test weight dockage among 21 North Carolina wheat purchasers, three typical market scenarios were used for modeling profitability: feed-wheat, flexible (feed or flour), and the flour market. A major finding was that, on average, MR cultivars were at least as profitable as S cultivars, regardless of epidemic severity or market. Fungicides were profitable in the feed-grain and flexible markets when DON was high, with MR cultivars in the flexible or flour markets when DON was intermediate, and on S cultivars aimed at the flexible market. The flour market was only profitable when FHB was present if DON levels were intermediate and cultivar

  3. Lower extremity work is associated with club head velocity during the golf swing in experienced golfers.

    Science.gov (United States)

    McNally, M P; Yontz, N; Chaudhari, A M

    2014-08-01

    While the golf swing is a complex whole body movement requiring coordination of all joints to achieve maximum ball velocity, the kinetic contribution of the lower extremities to club head velocity has not been quantified, despite the perception that the legs are a primary source of power during the swing. Mechanical power at the hips, knees, and ankles was estimated during the downswing phase of a full swing with a driver using a passive optical motion capture system and 2 force plates for adult males across a range of age and self-reported skill levels. Total work by the lower extremities was calculated by integrating the powers of all 6 joints over the downswing. Regression analyses showed that total lower extremity work was a strong predictor of club head velocity (R=0.63). Secondary analyses showed different relationships to club head velocity in lead and trail leg lower extremity joints, but none of these were as predictive of club head velocity as the total work performed by the lower extremities. These results provide quantitative evidence that the lower body's kinetic contribution may be an important factor in achieving greater club head velocity, contributing to greater driving distance and overall golf performance. © Georg Thieme Verlag KG Stuttgart · New York.

  4. DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration.

    Science.gov (United States)

    Dryden, Michael D M; Wheeler, Aaron R

    2015-01-01

    Most electroanalytical techniques require the precise control of the potentials in an electrochemical cell using a potentiostat. Commercial potentiostats function as "black boxes," giving limited information about their circuitry and behaviour which can make development of new measurement techniques and integration with other instruments challenging. Recently, a number of lab-built potentiostats have emerged with various design goals including low manufacturing cost and field-portability, but notably lacking is an accessible potentiostat designed for general lab use, focusing on measurement quality combined with ease of use and versatility. To fill this gap, we introduce DStat (http://microfluidics.utoronto.ca/dstat), an open-source, general-purpose potentiostat for use alone or integrated with other instruments. DStat offers picoampere current measurement capabilities, a compact USB-powered design, and user-friendly cross-platform software. DStat is easy and inexpensive to build, may be modified freely, and achieves good performance at low current levels not accessible to other lab-built instruments. In head-to-head tests, DStat's voltammetric measurements are much more sensitive than those of "CheapStat" (a popular open-source potentiostat described previously), and are comparable to those of a compact commercial "black box" potentiostat. Likewise, in head-to-head tests, DStat's potentiometric precision is similar to that of a commercial pH meter. Most importantly, the versatility of DStat was demonstrated through integration with the open-source DropBot digital microfluidics platform. In sum, we propose that DStat is a valuable contribution to the "open source" movement in analytical science, which is allowing users to adapt their tools to their experiments rather than alter their experiments to be compatible with their tools.

  5. DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration.

    Directory of Open Access Journals (Sweden)

    Michael D M Dryden

    Full Text Available Most electroanalytical techniques require the precise control of the potentials in an electrochemical cell using a potentiostat. Commercial potentiostats function as "black boxes," giving limited information about their circuitry and behaviour which can make development of new measurement techniques and integration with other instruments challenging. Recently, a number of lab-built potentiostats have emerged with various design goals including low manufacturing cost and field-portability, but notably lacking is an accessible potentiostat designed for general lab use, focusing on measurement quality combined with ease of use and versatility. To fill this gap, we introduce DStat (http://microfluidics.utoronto.ca/dstat, an open-source, general-purpose potentiostat for use alone or integrated with other instruments. DStat offers picoampere current measurement capabilities, a compact USB-powered design, and user-friendly cross-platform software. DStat is easy and inexpensive to build, may be modified freely, and achieves good performance at low current levels not accessible to other lab-built instruments. In head-to-head tests, DStat's voltammetric measurements are much more sensitive than those of "CheapStat" (a popular open-source potentiostat described previously, and are comparable to those of a compact commercial "black box" potentiostat. Likewise, in head-to-head tests, DStat's potentiometric precision is similar to that of a commercial pH meter. Most importantly, the versatility of DStat was demonstrated through integration with the open-source DropBot digital microfluidics platform. In sum, we propose that DStat is a valuable contribution to the "open source" movement in analytical science, which is allowing users to adapt their tools to their experiments rather than alter their experiments to be compatible with their tools.

  6. Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Wu Binbin, E-mail: binbin.wu@gunet.georgetown.edu [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Zahurak, Marianna [Department of Oncology Biostatistics, Johns Hopkins University, Baltimore, Maryland (United States); Simari, Patricio [Autodesk Research, Toronto, ON (Canada); Pang, Dalong [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Taylor, Russell [Department of Computer Science, Johns Hopkins University, Baltimore, Maryland (United States); Sanguineti, Giuseppe [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States)

    2012-12-01

    Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

  7. Fully Automated Simultaneous Integrated Boosted–Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

    International Nuclear Information System (INIS)

    Wu Binbin; McNutt, Todd; Zahurak, Marianna; Simari, Patricio; Pang, Dalong; Taylor, Russell; Sanguineti, Giuseppe

    2012-01-01

    Purpose: To prospectively determine whether overlap volume histogram (OVH)–driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

  8. HEAD MOVEMENT DURING WALKING IN THE CAT

    Science.gov (United States)

    ZUBAIR, HUMZA N.; BELOOZEROVA, IRINA N.; SUN, HAI; MARLINSKI, VLADIMIR

    2016-01-01

    Knowledge of how the head moves during locomotion is essential for understanding how locomotion is controlled by sensory systems of the head. We have analyzed head movements of the cat walking along a straight flat pathway in the darkness and light. We found that cats' head left-right translations, and roll and yaw rotations oscillated once per stride, while fore-aft and vertical translations, and pitch rotations oscillated twice. The head reached its highest vertical positions during second half of each forelimb swing, following maxima of the shoulder/trunk by 20–90°. Nose-up rotation followed head upward translation by another 40–90° delay. The peak-to-peak amplitude of vertical translation was ~1.5 cm and amplitude of pitch rotation was ~3°. Amplitudes of lateral translation and roll rotation were ~1 cm and 1.5–3°, respectively. Overall, cats' heads were neutral in roll and 10–30° nose-down, maintaining horizontal semicircular canals and utriculi within 10° of the earth horizontal. The head longitudinal velocity was 0.5–1 m/s, maximal upward and downward linear velocities were ~0.05 and ~0.1 m/s, respectively, and maximal lateral velocity was ~0.05 m/s. Maximal velocities of head pitch rotation were 20–50 °/s. During walking in light, cats stood 0.3–0.5 cm taller and held their head 0.5–2 cm higher than in darkness. Forward acceleration was 25–100% higher and peak-to-peak amplitude of head pitch oscillations was ~20 °/s larger. We concluded that, during walking, the head of the cat is held actively. Reflexes appear to play only a partial role in determining head movement, and vision might further diminish their role. PMID:27339731

  9. Synthetic Aperture Computation as the Head is Turned in Binaural Direction Finding

    Directory of Open Access Journals (Sweden)

    Duncan Tamsett

    2017-03-01

    Full Text Available Binaural systems measure instantaneous time/level differences between acoustic signals received at the ears to determine angles λ between the auditory axis and directions to acoustic sources. An angle λ locates a source on a small circle of colatitude (a lamda circle on a sphere symmetric about the auditory axis. As the head is turned while listening to a sound, acoustic energy over successive instantaneous lamda circles is integrated in a virtual/subconscious field of audition. The directions in azimuth and elevation to maxima in integrated acoustic energy, or to points of intersection of lamda circles, are the directions to acoustic sources. This process in a robotic system, or in nature in a neural implementation equivalent to it, delivers its solutions to the aurally informed worldview. The process is analogous to migration applied to seismic profiler data, and to that in synthetic aperture radar/sonar systems. A slanting auditory axis, e.g., possessed by species of owl, leads to the auditory axis sweeping the surface of a cone as the head is turned about a single axis. Thus, the plane in which the auditory axis turns continuously changes, enabling robustly unambiguous directions to acoustic sources to be determined.

  10. Validation of a noninvasive system for measuring head acceleration for use during boxing competition.

    Science.gov (United States)

    Beckwith, Jonathan G; Chu, Jeffrey J; Greenwald, Richard M

    2007-08-01

    Although the epidemiology and mechanics of concussion in sports have been investigated for many years, the biomechanical factors that contribute to mild traumatic brain injury remain unclear because of the difficulties in measuring impact events in the field. The purpose of this study was to validate an instrumented boxing headgear (IBH) that can be used to measure impact severity and location during play. The instrumented boxing headgear data were processed to determine linear and rotational acceleration at the head center of gravity, impact location, and impact severity metrics, such as the Head Injury Criterion (HIC) and Gadd Severity Index (GSI). The instrumented boxing headgear was fitted to a Hybrid III (HIII) head form and impacted with a weighted pendulum to characterize accuracy and repeatability. Fifty-six impacts over 3 speeds and 5 locations were used to simulate blows most commonly observed in boxing. A high correlation between the HIII and instrumented boxing headgear was established for peak linear and rotational acceleration (r2= 0.91), HIC (r2 = 0.88), and GSI (r2 = 0.89). Mean location error was 9.7 +/- 5.2 masculine. Based on this study, the IBH is a valid system for measuring head acceleration and impact location that can be integrated into training and competition.

  11. Effects of visual control training on the shooting performance of elite female basketball players

    NARCIS (Netherlands)

    Oudejans, R.R.D.

    2012-01-01

    In the current study, a method was tested to train visual control in basketball shooting. Using a sender/receiver system, Plato liquid-crystal goggles were wirelessly and manually controlled by the experimenter to manipulate vision of players while they were shooting. During the training the goggles

  12. Boxing-related head injuries.

    Science.gov (United States)

    Jayarao, Mayur; Chin, Lawrence S; Cantu, Robert C

    2010-10-01

    Fatalities in boxing are most often due to traumatic brain injury that occurs in the ring. In the past 30 years, significant improvements in ringside and medical equipment, safety, and regulations have resulted in a dramatic reduction in the fatality rate. Nonetheless, the rate of boxing-related head injuries, particularly concussions, remains unknown, due in large part to its variability in clinical presentation. Furthermore, the significance of repeat concussions sustained when boxing is just now being understood. In this article, we identify the clinical manifestations, pathophysiology, and management of boxing-related head injuries, and discuss preventive strategies to reduce head injuries sustained by boxers.

  13. Design improvement for partial penetration welds of Pressurizer heater sleeves to head junctures

    International Nuclear Information System (INIS)

    Kim, Jin-Seon; Lee, Kyoung-Jin; Park, Tae-Jung; Kim, Moo-Yong

    2007-01-01

    ASME Code, Section III allows partial penetration welds for openings for instrumentation on which there are substantially no piping reactions and requires to have interference fit or limited diametral clearance between nozzles and vessel penetrations for the partial penetration welds. Pressurizer heater sleeves are nonaxisymmetrically attached on the hill-side of bottom head by partial penetration welds. The excessive stresses in the partial penetration weld regions of the heater sleeves are induced by pressure and thermal transient loads and also by the deformation due to manual welding process. The purpose of this study is 1) to improve design for the partial penetration welds between heater sleeves to head junctures, 2) to demonstrate the structural integrity according to the requirements of ASME Code, Section III and 3) to improve welding procedure considering the proposed design

  14. Positron emission tomography-computed tomography protocol considerations for head and neck cancer imaging.

    Science.gov (United States)

    Escott, Edward J

    2008-08-01

    Positron emission tomographic-computed tomographic (PET-CT) imaging of patients with primary head and neck cancers has become an established approach for staging and restaging, as well as radiation therapy planning. The inherent co-registration of PET and CT images made possible by the integrated PET-CT scanner is particularly valuable in head and neck cancer imaging due to the complex and closely situated anatomy in this part of the body, the varied sources of physiologic and benign 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) tracer uptake that occurs in the neck, and the varied and complex posttreatment appearance of the neck. Careful optimization of both the CT and the PET portion of the examination is essential to insure the most accurate and clinically valuable interpretation of these examinations.

  15. A novel apparatus for interocular interaction evaluation in children with and without anisometropic amblyopia.

    Science.gov (United States)

    Lai, Xin Jie Angela; Alexander, Jack; He, Ming Guang; Yang, Zhi Kuan; Suttle, Catherine

    2012-07-01

    Dichoptic visual stimulation may be achieved using shutter goggles and mirror systems. These methods vary in their feasibility for use in children. This study aims to investigate the feasibility of use of a simple trial frame-based system to evaluate interactions in children. Low contrast acuity, contrast sensitivity and alignment sensitivity were measured in the non-dominant eye of 10 normally-sighted children, 14 anisometropic children without amblyopia and 14 anisometropic amblyopic children (aged 5-11 years) using goggles and a trial frame apparatus (TFA). The dominant eye was either fully or partially occluded. The difference in visual functions in the non-dominant eye between the full and partial occlusion conditions was termed the 'interaction index'. Agreement between the TFA and goggles in terms of visual functions and interactions was assessed in anisometropic children with and without amblyopia using the Bland-Altman method and t-test. Training sessions allowed subjects to become accustomed to the systems and tasks. The duration of training, the number of breaks requested by subjects and their willingness to attend further experiments were recorded in 10 subjects from each group and were compared between groups and between systems. Both Bland-Altman and t-test methods indicated acceptable agreement between the TFA and goggles in visual function and interaction measures (p > 0.05), except for contrast sensitivity measured in anisometropic children without amblyopia (p = 0.042). For all subject groups, contrast sensitivity training was significantly longer using goggles than using the TFA (p ≤ 0.001). Significantly more breaks were requested in acuity and contrast sensitivity testing, when goggles were used than when the TFA was used (p amblyopia showed a significantly greater willingness to attend more experiments using the TFA than using goggles (p = 0.025). The TFA may be a useful tool in studies of interactions in amblyopes, particularly in studies

  16. Design of a high-resolution optoelectronic retinal prosthesis.

    Science.gov (United States)

    Palanker, Daniel; Vankov, Alexander; Huie, Phil; Baccus, Stephen

    2005-03-01

    It has been demonstrated that electrical stimulation of the retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. However, current retinal implants provide very low resolution (just a few electrodes), whereas at least several thousand pixels would be required for functional restoration of sight. This paper presents the design of an optoelectronic retinal prosthetic system with a stimulating pixel density of up to 2500 pix mm(-2) (corresponding geometrically to a maximum visual acuity of 20/80). Requirements on proximity of neural cells to the stimulation electrodes are described as a function of the desired resolution. Two basic geometries of sub-retinal implants providing required proximity are presented: perforated membranes and protruding electrode arrays. To provide for natural eye scanning of the scene, rather than scanning with a head-mounted camera, the system operates similar to 'virtual reality' devices. An image from a video camera is projected by a goggle-mounted collimated infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. The goggles are transparent to visible light, thus allowing for the simultaneous use of remaining natural vision along with prosthetic stimulation. Optical delivery of visual information to the implant allows for real-time image processing adjustable to retinal architecture, as well as flexible control of image processing algorithms and stimulation parameters.

  17. Design of a high-resolution optoelectronic retinal prosthesis

    Science.gov (United States)

    Palanker, Daniel; Vankov, Alexander; Huie, Phil; Baccus, Stephen

    2005-03-01

    It has been demonstrated that electrical stimulation of the retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. However, current retinal implants provide very low resolution (just a few electrodes), whereas at least several thousand pixels would be required for functional restoration of sight. This paper presents the design of an optoelectronic retinal prosthetic system with a stimulating pixel density of up to 2500 pix mm-2 (corresponding geometrically to a maximum visual acuity of 20/80). Requirements on proximity of neural cells to the stimulation electrodes are described as a function of the desired resolution. Two basic geometries of sub-retinal implants providing required proximity are presented: perforated membranes and protruding electrode arrays. To provide for natural eye scanning of the scene, rather than scanning with a head-mounted camera, the system operates similar to 'virtual reality' devices. An image from a video camera is projected by a goggle-mounted collimated infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. The goggles are transparent to visible light, thus allowing for the simultaneous use of remaining natural vision along with prosthetic stimulation. Optical delivery of visual information to the implant allows for real-time image processing adjustable to retinal architecture, as well as flexible control of image processing algorithms and stimulation parameters.

  18. Tackler’s head position relative to the ball carrier is highly correlated with head and neck injuries in rugby

    Science.gov (United States)

    Hasegawa, Yoshinori; Shiota, Yuki; Ota, Chihiro; Yoneda, Takeshi; Tahara, Shigeyuki; Maki, Nobukazu; Matsuura, Takahiro; Sekiguchi, Masahiro; Itoigawa, Yoshiaki; Tateishi, Tomohiko; Kaneko, Kazuo

    2018-01-01

    Objectives To characterise the tackler’s head position during one-on-one tackling in rugby and to determine the incidence of head, neck and shoulder injuries through analysis of game videos, injury records and a questionnaire completed by the tacklers themselves. Methods We randomly selected 28 game videos featuring two university teams in competitions held in 2015 and 2016. Tackles were categorised according to tackler’s head position. The ‘pre-contact phase’ was defined; its duration and the number of steps taken by the ball carrier prior to a tackle were evaluated. Results In total, 3970 tackles, including 317 (8.0%) with the tackler’s head incorrectly positioned (ie, in front of the ball carrier) were examined. Thirty-two head, neck or shoulder injuries occurred for an injury incidence of 0.8% (32/3970). The incidence of injury in tackles with incorrect head positioning was 69.4/1000 tackles; the injury incidence with correct head positioning (ie, behind or to one side of the ball carrier) was 2.7/1000 tackles. Concussions, neck injuries, ‘stingers’ and nasal fractures occurred significantly more often during tackles with incorrect head positioning than during tackles with correct head positioning. Significantly fewer steps were taken before tackles with incorrect head positioning that resulted in injury than before tackles that did not result in injury. Conclusion Tackling with incorrect head position relative to the ball carrier resulted in a significantly higher incidence of concussions, neck injuries, stingers and nasal fractures than tackling with correct head position. Tackles with shorter duration and distance before contact resulted in more injuries. PMID:29162618

  19. Perspectives about family meals from single-headed and dual-headed households: a qualitative analysis.

    Science.gov (United States)

    Berge, Jerica M; Hoppmann, Caroline; Hanson, Carrie; Neumark-Sztainer, Dianne

    2013-12-01

    Cross-sectional and longitudinal research has shown that family meals are protective for adolescent healthful eating behaviors. However, little is known about what parents think of these findings and whether parents from single- vs dual-headed households have differing perspectives about the findings. In addition, parents' perspectives regarding barriers to applying the findings on family meals in their own homes and suggestions for more widespread adoption of the findings are unknown. The current study aimed to identify single- and dual-headed household parents' perspectives regarding the research findings on family meals, barriers to applying the findings in their own homes, and suggestions for helping families have more family meals. The current qualitative study included 59 parents who participated in substudy of two linked multilevel studies-EAT 2010 (Eating and Activity in Teens) and Families and Eating and Activity in Teens (F-EAT). Parents (91.5% female) were racially/ethnically and socioeconomically diverse. Data were analyzed using a grounded theory approach. Results from the current study suggest that parents from both single- and dual-headed households have similar perspectives regarding why family meals are protective for healthful eating habits for adolescents (eg, provides structure/routine, opportunities for communication, connection), but provide similar and different reasons for barriers to family meals (eg, single-headed=cost vs dual-headed=lack of creativity) and ideas and suggestions for how to increase the frequency of family meals (eg, single-headed=give fewer options vs dual-headed=include children in the meal preparation). Findings can help inform public health intervention researchers and providers who work with adolescents and their families to understand how to approach discussions regarding reasons for having family meals, barriers to carrying out family meals, and ways to increase family meals depending on family structure. Copyright

  20. Can ultrasound elastography distinguish metastatic from reactive lymph nodes in patients with primary head and neck cancers?

    Directory of Open Access Journals (Sweden)

    Mohamed Mohamed Hefeda

    2014-09-01

    Conclusions: The accuracy of sonoelastography is higher than usual B mode and power Doppler ultrasound parameters in differentiation between benign and malignant nodes. The integration of lymph node sonoelastography in the follow up of patients with known head and neck cancer may reduce the number of biopsies.

  1. Preschool Facilities - MDC_HeadStart

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — A label (point) feature class of Head Start / Early Head Start/ Delegate Agencies/ Child Care Partnership & Family Day Care Homes Programs location in Miami-Dade...

  2. Tissue integration in oral and maxillo-facial reconstruction

    International Nuclear Information System (INIS)

    Van Steenberghe, D.

    1986-01-01

    These proceedings on tissue-integrated prostheses in the rehabilitation of the head and neck area cover both basic scientific and clinical aspects in intra- as well as extra-oral applications. Also the discussions and conclusions of the 'State-of-the-Art' meeting are included. (Auth.)

  3. 29 CFR 1620.21 - Head of household.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Head of household. 1620.21 Section 1620.21 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION THE EQUAL PAY ACT § 1620.21 Head of household. Since a “head of household” or “head of family” status bears no relationship to the...

  4. Get a head in telepresence: active vision for remote intervention

    International Nuclear Information System (INIS)

    Pretlove, J.

    1996-01-01

    Despite advances in robotic systems, many tasks needing to be undertaken in hazardous environments require human control. The risk to human life can be reduced or minimised using an integrated control system comprising an active controllable stereo vision system and a virtual reality head-mounted display. The human operator is then immersed in and can interact with the remote environment in complete safety. An overview is presented of the design and development of just such an advanced, dynamic telepresence system, developed at the Department of Mechanical Engineering at the University of Surrey. (UK)

  5. 21 CFR 868.1930 - Stethoscope head.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stethoscope head. 868.1930 Section 868.1930 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1930 Stethoscope head. (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and...

  6. 29 CFR 1918.103 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1918.103 Section 1918.103 Labor... must ensure that head protection complies with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  7. 29 CFR 1915.155 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1915.155 Section 1915.155 Labor... helmets. (1) Head protection must comply with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  8. 29 CFR 1910.135 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Head protection. 1910.135 Section 1910.135 Labor... head protection. (1) Head protection must comply with any of the following consensus standards: (i... consensus standards will be deemed to be in compliance with the requirements of this section. [59 FR 16362...

  9. 29 CFR 1926.100 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Head protection. 1926.100 Section 1926.100 Labor... § 1926.100 Head protection. (a) Employees working in areas where there is a possible danger of head... protected by protective helmets. (b) Helmets for the protection of employees against impact and penetration...

  10. Head impact in a snowboarding accident.

    Science.gov (United States)

    Bailly, N; Llari, M; Donnadieu, T; Masson, C; Arnoux, P J

    2017-09-01

    To effectively prevent sport traumatic brain injury (TBI), means of protection need to be designed and tested in relation to the reality of head impact. This study quantifies head impacts during a typical snowboarding accident to evaluate helmet standards. A snowboarder numerical model was proposed, validated against experimental data, and used to quantify the influence of accident conditions (speed, snow stiffness, morphology, and position) on head impacts (locations, velocities, and accelerations) and injury risk during snowboarding backward falls. Three hundred twenty-four scenarios were simulated: 70% presented a high risk of mild TBI (head peak acceleration >80 g) and 15% presented a high risk of severe TBI (head injury criterion >1000). Snow stiffness, speed, and snowboarder morphology were the main factors influencing head impact metrics. Mean normal head impact speed (28 ± 6 km/h) was higher than equivalent impact speed used in American standard helmet test (ASTM F2040), and mean tangential impact speed, not included in standard tests, was 13.8 (±7 km/h). In 97% of simulated impacts, the peak head acceleration was below 300 g, which is the pass/fail criteria used in standard tests. Results suggest that initial speed, impacted surface, and pass/fail criteria used in helmet standard performance tests do not fully reflect magnitude and variability of snowboarding backward-fall impacts. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Posture of the head and pharyngeal swallowing

    International Nuclear Information System (INIS)

    Ekberg, O.

    1986-01-01

    Closure of the laryngeal vestibule during swallowing is important for protection of the airways. The present investigation included 53 patients with dysphagia examined cineradiographically with the head held in resting posture, flexion and extension. The ability to protect the airways by the downward movement of the epiglottis and by obliteration of the laryngeal vestibule was studied in different postures of the head. Of 35 patients with normal laryngeal obliteration with the head in resting position 10 showed a defective closure at swallowing in extension. In 18 patients with defective closure of the laryngeal vestibule in resting position 9 were improved on flexion and two on extension of the head. In one patient with defectie closure of the laryngeal vestibule in resting position swallowing in flexion showed an aggravated dysfunction. In our other patients the defective closure became more marked on extension. Four patients had less effective downward movement of the epiglottis with the head in extension. Of 10 patients with defective epiglottic movement with the head in resting position two were improved on tilting the head forwards. The results show that the position of the head influences the closure of the airways during swallowing. Patients with defective protection of the laryngeal vestibule should be instructed to swallow with the head tilted forwards. (orig.)

  12. Dental and nutritional management of the head and neck cancer patient

    International Nuclear Information System (INIS)

    Lee, W. Robert; Sandow, Pamela L.; Moore, Giselle J.

    1995-01-01

    This course will examine the expected acute and late normal tissue toxicities associated with the delivery of high dose radiation therapy to the head and neck region. The purpose of this course will be to identify strategies to reduce radiotherapy-related toxicity without compromising adequate tumor treatment. A multidisciplinary approach will be emphasized and the following topics will be addressed: 1) Appropriate dental evaluation prior to the institution of treatment, oral care during radiation therapy and management of dental complications following completion of treatment. 2) Treatment techniques that accurately localize the target tissue, displace normal tissues from high dose volume and reduce the volume of normal tissue included in the radiation portals. 3) The investigative use of radioprotective agents. 4) Optimal integration of radiotherapy with surgery and/or chemotherapy. 5) The nutritional management of head and neck cancer patients including enteral and parenteral nutrition. 6) The use of medications to reduce the severity of acute symptomatology before, during and after radiation therapy

  13. A Practical Method for Implementing an Attitude and Heading Reference System

    Directory of Open Access Journals (Sweden)

    Rodrigo Munguía

    2014-04-01

    Full Text Available This paper describes a practical and reliable algorithm for implementing an Attitude and Heading Reference System (AHRS. This kind of system is essential for real time vehicle navigation, guidance and control applications. When low cost sensors are used, efficient and robust algorithms are required for performance to be acceptable. The proposed method is based on an Extended Kalman Filter (EKF in a direct configuration. In this case, the filter is explicitly derived from both the kinematic and error models. The selection of this kind of EKF configuration can help in ensuring a tight integration of the method for its use in filter-based localization and mapping systems in autonomous vehicles. Experiments with real data show that the proposed method is able to maintain an accurate and drift-free attitude and heading estimation. An additional result is to show that there is no ostensible reason for preferring that the filter have an indirect configuration over a direct configuration for implementing an AHRS system.

  14. Unilateral otolith centrifugation by head tilt.

    Science.gov (United States)

    Winters, Stephanie M; Bos, Jelte E; Klis, Sjaak F L

    2014-01-01

    To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. To test a new, more simple method of unilateral stimulation with head tilt and the body remaining on axis. During stationary and during 360 deg/s rotation, 12 healthy blindfolded subjects had their heads tilted 30 degrees sideways, positioning one otolithic organ on the axis of rotation after the other. The haptic subjective vertical (SV) was recorded several times by means of a manually adjustable rod. It was found that during stationary the SV tilted about 4 degrees on average in the direction of the head. During rotation, the SV tilted about 9 degrees on average. We therefore estimate the effect of eccentric otolith rotation to be 5 degrees on average. Tilt of the subjective vertical induced by head tilt during on-axis body rotation can provide a relatively uncomplicated alternative to test unilateral otolithic function as compared to body and head translation during rotation. Moreover, unlike eccentric rotation of the entire body, somatosensory cues are minimized by keeping the body fixed on axis and by subtracting the effect of head tilt per se.

  15. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  16. Additional value of integrated PET/CT over PET alone in the initial staging and follow up of head and neck malignancy

    International Nuclear Information System (INIS)

    Ishikita, Tomohiro; Oriuchi, Noboru; Higuchi, Tetsuya

    2010-01-01

    Clinical application of fluorodeoxyglucose (FDG)-positron emission tomography (PET) in head and neck cancer includes identification of metastases, unknown primary head and neck malignancy, or second primary carcinoma, and also recurrent tumor after treatment. In this study, the additional value of PET/CT fusion images over PET images alone was evaluated in patients with initial staging and follow up of head and neck malignancy. Forty patients with suspected primary head and neck malignancy and 129 patients with suspected relapse after treatment of head and neck malignancy were included. FDG-PET/CT study was performed after the intravenous administration of FDG (5 MBq/kg). Target of evaluation was set at primary tumor, cervical lymph node, and whole body. PET images and PET with CT fusion images were compared. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results of PET and PET/CT were compared with postoperative histopathological examination, and case by case comparison of PET and PET/CT results for each region was performed. The additional value of CT images over PET only images was assessed. Statistical differences in sensitivity and specificity were evaluated. In the comparative evaluation of 507 targets by PET alone and PET/CT, 401 targets showed agreement of the results. Of the 106 discordant targets, 103 showed a positive result on PET alone and negative result on PET/CT. These results showed a significant difference (p<0.01). Sensitivity of PET/CT was slightly higher than that of PET without statistical significance, while specificity of PET/CT was significantly higher than that of PET alone (Initial Staging: 90.5% vs. 62.2%, p<0.01; Follow up: 97.2% vs. 74.4%, p<0.01). In Fisher's direct probability test, a significant difference was noted in the sensitivity (Initial staging: 91.3% vs. 87.0%, p<0.01; Follow up: 93.9% vs. 91.4%, p<0.01). Combined PET/CT showed improved diagnostic

  17. First Class Call Stacks: Exploring Head Reduction

    Directory of Open Access Journals (Sweden)

    Philip Johnson-Freyd

    2016-06-01

    Full Text Available Weak-head normalization is inconsistent with functional extensionality in the call-by-name λ-calculus. We explore this problem from a new angle via the conflict between extensionality and effects. Leveraging ideas from work on the λ-calculus with control, we derive and justify alternative operational semantics and a sequence of abstract machines for performing head reduction. Head reduction avoids the problems with weak-head reduction and extensionality, while our operational semantics and associated abstract machines show us how to retain weak-head reduction's ease of implementation.

  18. Recent results of cetuximab use in the treatment of squamous cell carcinoma of the head and neck

    Directory of Open Access Journals (Sweden)

    Francesco Perri

    2009-08-01

    Full Text Available Francesco Perri1, Francesco Longo2, Franco Ionna2, Francesco Caponigro11Head and Neck Medical Oncology Unit, 2Head and Neck Surgery Unit, National Tumor Institute of Naples, Naples, ItalyAbstract: Cetuximab is a chimeric monoclonal antibody that targets the epidermal growth factor receptor. The role of cetuximab is paramount in several subsets of head and neck cancer. In particular, the EXTREME study has indicated cetuximab as the only drug to improve survival when associated with cisplatin and 5-fluorouracil in patients with recurrent/metastatic disease. Furthermore, cetuximab, both alone and in combination with cisplatin, is active in patients with recurrent/metastatic disease who have failed prior platinum-based chemotherapy. Cetuximab, given in association with radiation therapy, is a treatment of choice in first-line therapy of patients with locally advanced inoperable disease. In the same setting, the role of induction chemotherapy has gained considerable interest over the last few years and a number of efforts are being pursued to optimally integrate induction chemotherapy with radiation therapy plus cetuximab. The combination of cetuximab and other targeted therapies is among the most promising new perspectives for patients with head and neck cancer.Keywords: cetuximab, head and neck cancer, locally advanced, recurrent/metastatic

  19. Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy?

    International Nuclear Information System (INIS)

    Georg, Dietmar; Bogner, Joachim; Dieckmann, Karin; Poetter, Richard

    2006-01-01

    Background: The aim of this study was to compare setup accuracy and reproducibility of a stereotactic head and a head-and-neck fixation system, both based on thermoplastic material. Methods and Material: Ten patients were immobilized with a head and a head-and-neck fixation system (both BrainLAB, Germany). Both mask systems were modified with a custom-made mouthpiece and a strip of thermoplastic material attached to the lower part of the mask. During the first treatment session, after positioning patients using room lasers, two orthogonal portal images were taken as reference. Later on, at least five sets of orthogonal portal images were acquired for each patient. The isocentric setup accuracy was determined by comparing field edges and anatomic landmarks and the repositioning accuracy in the mask was obtained by comparing individual anatomic landmarks with respect to the metal balls, fixed on the masks. Systematic and random deviations and resulting three-dimensional (3D) vectors were calculated. Additionally, margins were derived from the systematic and random component of the isocentric setup accuracy. Finally, inter- and intraobserver variations were analyzed. Results: The systematic variation of the isocentric setup accuracy was very similar for the two mask systems, but the random variations were slightly larger for the head-and-neck system, resulting in a 0.4-mm larger 3D vector. The repositioning variations for the head mask were smaller compared with the head-and-neck mask, resulting in smaller 3D vectors for the random (∼0.4 mm) and systematic variations (∼0.6 mm). For both mask systems, a 2-mm margin can be used in lateral and anteroposterior direction, whereas in craniocaudal direction, this margin should be extended to 2.5 mm for the head mask and to 3 mm for the head-and-neck mask. The average absolute differences between two observers were within 0.5 mm, maximum deviations around 1 mm. Conclusion: Thermoplastic mask-based stereotactic head

  20. Precision Medicine in Head and Neck Cancer: Myth or Reality?

    Science.gov (United States)

    Malone, Eoghan; Siu, Lillian L

    2018-01-01

    Standard treatment in head and neck squamous cell carcinoma (HNSCC) is limited currently with decisions being made primarily based on tumor location, histology, and stage. The role of the human papillomavirus in risk stratification is actively under clinical trial evaluations. The molecular complexity and intratumoral heterogeneity of the disease are not actively integrated into management decisions of HNSCC, despite a growing body of knowledge in these areas. The advent of the genomic era has delivered vast amounts of information regarding different cancer subtypes and is providing new therapeutic targets, which can potentially be elucidated using next-generation sequencing and other modern technologies. The task ahead is to expand beyond the existent armamentarium by exploiting beyond the genome and perform integrative analysis using innovative systems biology methods, with the goal to deliver effective precision medicine-based theragnostic options in HNSCC.

  1. Experimental Creep Life Assessment for the Advanced Stirling Convertor Heater Head

    Science.gov (United States)

    Krause, David L.; Kalluri, Sreeramesh; Shah, Ashwin R.; Korovaichuk, Igor

    2010-01-01

    The United States Department of Energy is planning to develop the Advanced Stirling Radioisotope Generator (ASRG) for the National Aeronautics and Space Administration (NASA) for potential use on future space missions. The ASRG provides substantial efficiency and specific power improvements over radioisotope power systems of heritage designs. The ASRG would use General Purpose Heat Source modules as energy sources and the free-piston Advanced Stirling Convertor (ASC) to convert heat into electrical energy. Lockheed Martin Corporation of Valley Forge, Pennsylvania, is integrating the ASRG systems, and Sunpower, Inc., of Athens, Ohio, is designing and building the ASC. NASA Glenn Research Center of Cleveland, Ohio, manages the Sunpower contract and provides technology development in several areas for the ASC. One area is reliability assessment for the ASC heater head, a critical pressure vessel within which heat is converted into mechanical oscillation of a displacer piston. For high system efficiency, the ASC heater head operates at very high temperature (850 C) and therefore is fabricated from an advanced heat-resistant nickel-based superalloy Microcast MarM-247. Since use of MarM-247 in a thin-walled pressure vessel is atypical, much effort is required to assure that the system will operate reliably for its design life of 17 years. One life-limiting structural response for this application is creep; creep deformation is the accumulation of time-dependent inelastic strain under sustained loading over time. If allowed to progress, the deformation eventually results in creep rupture. Since creep material properties are not available in the open literature, a detailed creep life assessment of the ASC heater head effort is underway. This paper presents an overview of that creep life assessment approach, including the reliability-based creep criteria developed from coupon testing, and the associated heater head deterministic and probabilistic analyses. The approach also

  2. Current Assessment of Integrated Content of Long-Lived Radionuclides in Soils of the Head Part of the East Ural Radioactive Trace - Current Assessment of Integrated Stocks of Long-Lived Radionuclides in Soils of the Head Part of the East-Ural Radioactive Trace

    Energy Technology Data Exchange (ETDEWEB)

    Antonov, Konstantin L. [Institute of Industrial Ecology UB RAS, 620990 Kovalevskoy St., 20, Ekaterinburg (Russian Federation); Molchanova, Inna V.; Mikhailovskaya, Lyudmila N.; Pozolotina, Vera N.; Antonova, Elena V. [Institute of Plant and Animal Ecology UB RAS, 8 Marta St., 202, 620144 Ekaterinburg (Russian Federation)

    2014-07-01

    The East Ural Radioactive Trace is a result of the accident at the Production Association Mayak in 1957(the Kyshtym accident). The {sup 90}Sr was the main contaminant among long-lived radionuclides. Most of it was concentrated in the zone closest to the accident epicentre to the north-west (a narrow sector of about 15 deg., 35 km long). Later, in 1967, the EURT area was contaminated again with air-borne radioactive sediments from Lake Karachay, which had been used by the PA Mayak for storage of liquid radioactive waste. At this case the primary contaminant was {sup 137}Cs most of which was spread within 60 deg. sector oriented in the same direction (Aarkrog et al., 1997; Romanov et al., 1990). Our earlier radioecological studies included the assessment of integrated quantities of {sup 90}Sr, {sup 137}Cs, and {sup 239,240}Pu within the central axis of the trace (Pozolotina et al., 2008; Molchanova et al., 2009). The aim of this investigation was the current assessment of integrated stocks of {sup 90}Sr, {sup 137}Cs, and {sup 239,240}Pu in soils of the head part of the EURT along the central axis and the adjacent areas, to map the contamination data of the studied area using established geostatistical models by ArcGIS 9.3 (ESRI, USA). An inventory of the existing data (38 sampling locations) was performed earlier (Molchanova et al., 2009). Currently the database has information on 102 soil profile cuts. Taking into account the presence of global trends and anisotropy in the source data, ordinary kriging interpolation method was used. Geostatistical data analysis was performed for the determination of the basic parameters of spatial dependencies and the integral assessment of long-lived radionuclides in soils of the central, east peripheral, and west one parts of the trace. This analysis employed simplified geometric models (sector- and rectangle-shaped areas). The Monte Carlo technique was used for quantitatively assesses the uncertainty of the integrated stocks to

  3. Head flexion angle while using a smartphone.

    Science.gov (United States)

    Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob

    2015-01-01

    Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.

  4. Prediction value of the Canadian CT head rule and the New Orleans criteria for positive head CT scan and acute neurosurgical procedures in minor head trauma: a multicenter external validation study.

    Science.gov (United States)

    Bouida, Wahid; Marghli, Soudani; Souissi, Sami; Ksibi, Hichem; Methammem, Mehdi; Haguiga, Habib; Khedher, Sonia; Boubaker, Hamdi; Beltaief, Kaouthar; Grissa, Mohamed Habib; Trimech, Mohamed Naceur; Kerkeni, Wiem; Chebili, Nawfel; Halila, Imen; Rejeb, Imen; Boukef, Riadh; Rekik, Noureddine; Bouhaja, Bechir; Letaief, Mondher; Nouira, Semir

    2013-05-01

    The New Orleans Criteria and the Canadian CT Head Rule have been developed to decrease the number of normal computed tomography (CT) results in mild head injury. We compare the performance of both decision rules for identifying patients with intracranial traumatic lesions and those who require an urgent neurosurgical intervention after mild head injury. This was an observational cohort study performed between 2008 and 2011 on patients with mild head injury who were aged 10 years or older. We collected prospectively clinical head CT scan findings and outcome. Primary outcome was need for neurosurgical intervention, defined as either death or craniotomy, or the need of intubation within 15 days of the traumatic event. Secondary outcome was the presence of traumatic lesions on head CT scan. New Orleans Criteria and Canadian CT Head Rule decision rules were compared by using sensitivity specifications and positive and negative predictive value. We enrolled 1,582 patients. Neurosurgical intervention was performed in 34 patients (2.1%) and positive CT findings were demonstrated in 218 patients (13.8%). Sensitivity and specificity for need for neurosurgical intervention were 100% (95% confidence interval [CI] 90% to 100%) and 60% (95% CI 44% to 76%) for the Canadian CT Head Rule and 82% (95% CI 69% to 95%) and 26% (95% CI 24% to 28%) for the New Orleans Criteria. Negative predictive values for the above-mentioned clinical decision rules were 100% and 99% and positive values were 5% and 2%, respectively, for the Canadian CT Head Rule and New Orleans Criteria. Sensitivity and specificity for clinical significant head CT findings were 95% (95% CI 92% to 98%) and 65% (95% CI 62% to 68%) for the Canadian CT Head Rule and 86% (95% CI 81% to 91%) and 28% (95% CI 26% to 30%) for the New Orleans Criteria. A similar trend of results was found in the subgroup of patients with a Glasgow Coma Scale score of 15. For patients with mild head injury, the Canadian CT Head Rule had higher

  5. Head and Neck Cancer Treatment

    Science.gov (United States)

    ... Professions Site Index A-Z Head and Neck Cancer Treatment Head and neck cancer overview What are my ... and neck cancer. For updated information on new cancer treatments that are available, you should discuss these issues ...

  6. Head Lice: Prevention and Control

    Science.gov (United States)

    ... and General Public. Contact Us Parasites Home Prevention & Control Language: English (US) Español (Spanish) Recommend on Facebook ... that can be taken to help prevent and control the spread of head lice: Avoid head-to- ...

  7. Anaphylaxis due to head injury.

    Science.gov (United States)

    Bruner, Heather C; Bruner, David I

    2015-05-01

    Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury.

  8. Intensity-modulated radiotherapy using simultaneous-integrated boost for definitive treatment of locally advanced mucosal head and neck cancer: outcomes from a single-institution series

    International Nuclear Information System (INIS)

    Johnston, Meredith; Guo, Linxin; Hanna, Catherine; Back, Michael; Guminski, Alex; Lee, Adrian; Eade, Thomas; Veivers, David; Wignall, Andrew

    2013-01-01

    The study aims to report outcomes for patients treated using intensity-modulated radiotherapy (IMRT) with simultaneous-integrated boost and weekly cisplatin for American Joint Committee on Cancer stage III/IV mucosal head and neck squamous cell carcinomas (HNSCCs). Records for 67 patients treated definitively with IMRT for HNSCC were reviewed. By including only those treated with weekly cisplatin, 45 patients were eligible for analysis. Treatment outcomes, effect of patient, tumour and treatment characteristics on disease recurrence were analysed. All patients completed IMRT to 7000cGy in 35 fractions, with concurrent weekly cisplatin 40mg/m 2 (median 6 cycles). Median follow-up was 28 months for living patients. Two-year loco-regional recurrence-free, metastasis-free and overall survival were 85.4, 81.0 and 87.4%, respectively. Local recurrence occurred in three patients, and distant recurrence in eight patients. Our results show efficacy of IMRT and weekly cisplatin in the treatment of stage III/IV HNSCC at our institution with respect to loco-regional control.

  9. The impact of Chinese cultural values on Taiwan nursing leadership styles: comparing the self-assessments of staff nurses and head nurses.

    Science.gov (United States)

    Chang, Yuanmay

    2008-06-01

    The purpose of this study was to investigate the influence of Chinese culture on nursing leadership behavior in Taiwan nurses. A descriptive study compared staff nurses' assessment of Chinese value in the leadership behavior of their head nurses. Data analysis was made on a convenience sample in Taiwan of 214 head nurses and 2,127 staff nurses who had worked with their head nurse for at least one year. Six medical centers and regional hospitals in northern (Taipei), central (Taichung) and southern (Kaohsiung) Taiwan were recruited for this study. Instruments included the demographic questionnaire, Chinese Value Survey, and Kang's Chinese Leadership Behaviors Module Scale. Results indicated that head nurses scored significantly higher than staff nurses in terms of all cultural values and leadership behaviors. Both staff nurses and head nurses scored the highest mean scores in personal integrity (Yi) and human connectedness (Ren) and the lowest in moral discipline (Li). Staff nurse perceptions of leadership behavior indicated the role of parent to be higher than either the role of director or mentor. Head nurses perceptions of leadership behavior emphasized the role of the director more than either parent or mentor. There were no significant differences between the staff nurses and head nurses in terms of expectative leadership behavior, which gave the role of director higher mean scores than those of either the parent or mentor. Positive and significant associations (r = .266 to r = .334) were found between cultural values and perceptions of leadership behavior. Cultural values predicted 10.6% of leadership behavior variance. The three demographic characteristics of location in northern Taiwan (beta = .09), intention to leave (beta = -.14), and general unit (beta = .10) and the two cultural values of human connectedness (Ren) (beta = .16) and personal integrity (Yi) (beta = .16) together reported a cumulative R2 of 14.6% to explain variance in leadership behavior

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  11. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ...

  12. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

    Science.gov (United States)

    Chen, Kevin T; Izquierdo-Garcia, David; Poynton, Clare B; Chonde, Daniel B; Catana, Ciprian

    2017-03-01

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.

  13. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Kevin T. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts Institute of Technology, Division of Health Sciences and Technology, Cambridge, MA (United States); Izquierdo-Garcia, David; Catana, Ciprian [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Poynton, Clare B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Massachusetts General Hospital, Department of Psychiatry, Boston, MA (United States); University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Chonde, Daniel B. [Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, MA (United States); Harvard University, Program in Biophysics, Cambridge, MA (United States)

    2017-03-15

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps (''μ-maps'') were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map (''PAC-map'') generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach. (orig.)

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  15. Navigating Motherhood and the Role of the Head Athletic Trainer in the Collegiate Setting.

    Science.gov (United States)

    Mazerolle, Stephanie M; Eason, Christianne M

    2016-07-01

    Motherhood has been identified as a barrier to the head athletic trainer (AT) position. Role models have been cited as a possible facilitator for increasing the number of women who pursue and maintain this role in the collegiate setting. To examine the experiences of female ATs balancing motherhood and head AT positions in the National Collegiate Athletic Association Division II and III and National Association of Intercollegiate Athletics settings. Qualitative study. National Collegiate Athletic Association Divisions II and III and National Association of Intercollegiate Athletics. A total of 22 female head ATs (average age = 40 ± 8 years) who were married with children completed our study. Our participants had been certified for 15.5 ± 7.5 years and in their current positions as head ATs for 9 ± 8 years. We conducted online interviews with all participants. Participants journaled their reflections on a series of open-ended questions pertaining to their experiences as head ATs. Data were analyzed following a general inductive approach. Credibility was confirmed through peer review and researcher triangulation. We identified 3 major contributors to work-life conflict. Two speak to organizational influences on conflict: work demands and time of year. The role of motherhood, which was more of a personal contributor, also precipitated conflict for our ATs. Four themes emerged as work-life balance facilitators: planning, attitude and perspective, support networks, and workplace integration. Support was defined at both the personal and professional levels. In terms of the organization, our participants juggled long work hours, travel, and administrative tasks. Individually and socioculturally, they overcame their guilt and their need to be present and an active part of the parenting process. These mothers demonstrated the ability to cope with their demanding roles as both moms and head ATs.

  16. Small head size after atomic irradiation

    International Nuclear Information System (INIS)

    Miller, R.W.; Mulvihill, J.J.

    1975-01-01

    A study of children exposed to nuclear explosions in Hiroshima and Nagasaki showed small head size and mental retardation when exposure occurred less than 18 weeks of gestational age. Increased frequency of small head size occurred when maternal exposure was 10 to 19 rad. Tables and graphs are presented to show relationships between dose, gestational age, and frequency of small head size

  17. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  18. Kinematics of the human mandible for different head postures.

    Science.gov (United States)

    Visscher, C M; Huddleston Slater, J J; Lobbezoo, F; Naeije, M

    2000-04-01

    The influence of head posture on movement paths of the incisal point (IP) and of the mandibular condyles during free open-close movements was studied. Ten persons, without craniomandibular or cervical spine disorders, participated in the study. Open close mandibular movements were recorded with the head in five postures, viz., natural head posture, forward head posture, military posture, and lateroflexion to the right and to the left side, using the Oral Kinesiologic Analysis System (OKAS-3D). This study showed that in a military head posture, the opening movement path of the incisal point is shifted anteriorly relative to the path in a natural head posture. In a forward head posture, the movement path is shifted posteriorly whereas during lateroflexion, it deviates to the side the head has moved to. Moreover, the intra-articular distance in the temporomandibular joint during closing is smaller with the head in military posture and greater in forward head posture, as compared to the natural head posture. During lateroflexion, the intra-articular distance on the ipsilateral side is smaller. The influence of head posture upon the kinematics of the mandible is probably a manifestation of differences in mandibular loading in the different head postures.

  19. Customizable rigid head fixation for infants: technical note.

    Science.gov (United States)

    Udayakumaran, Suhas; Onyia, Chiazor U

    2016-01-01

    The need and advantages of rigid fixation of the head in cranial surgeries are well documented (Berryhill et al., Otolaryngol Head Neck Surg 121:269-273, 1999). Head fixation for neurosurgical procedures in infants and in early years has been a challenge and is fraught with risk. Despite the fact that pediatric pins are designed, rigid head fixation involving direct application of pins to the head of infants and slightly older children is still generally not safe (Agrawal and Steinbok, Childs Nerv Syst 22:1473-1474, 2006). Yet, there are some surgeries in which some form of rigid fixation is required (Agrawal and Steinbok, Childs Nerv Syst 22:1473-1474, 2006). We describe a simple technique to achieve rigid fixation of the head in infants for neurosurgical procedures. This involves applying a head band made of Plaster of Paris (POP) around the head and then applying the fixation pins of the fixation frame directly on to the POP. We have used this technique of head fixation successfully for infants with no complications.

  20. Head and neck cancer in South Asia: Macroeconomic consequences and the role of the head and neck surgeon.

    Science.gov (United States)

    Alkire, Blake C; Bergmark, Regan W; Chambers, Kyle; Lin, Derrick T; Deschler, Daniel G; Cheney, Mack L; Meara, John G

    2016-08-01

    Head and neck cancer constitutes a substantial portion of the burden of disease in South Asia, and there is an undersupply of surgical capacity in this region. The purpose of this study was to estimate the economic welfare losses due to head and neck cancer in India, Pakistan, and Bangladesh in 2010. We used publicly available estimates of head and neck cancer morbidity and mortality along with a concept termed the value of a statistical life to estimate economic welfare losses in the aforementioned countries in 2010. Economic losses because of head and neck cancer in India, Pakistan, and Bangladesh totaled $16.9 billion (2010 US dollars [USD]), equivalent to 0.26% of the region's economic output. Bangladesh, the poorest country, experienced the greatest proportional losses. The economic consequences of head and neck cancer in South Asia are significant, and building surgical capacity is essential to begin to address this burden. © 2016 Wiley Periodicals, Inc. Head Neck 38:1242-1247, 2016. © 2016 Wiley Periodicals, Inc.

  1. Head injury in children

    International Nuclear Information System (INIS)

    Sugiura, Makoto; Mori, Nobuhiko; Yokosuka, Reiko; Yamamoto, Masaaki; Imanaga, Hirohisa

    1981-01-01

    Findings of computerized tomography (CT) in 183 cases of head injury in children were investigated with special reference to CT findings of mild head injury. As was expected, CT findings of mild head injury fell within the normal range, in almost all cases. However, abnormal findings were noticed in 4 out of 34 cases (12%) in acute stage and 7 out of 76 cases (9%) in chronic stage. They were 3 cases of localized low density area in acute stage and 6 cases of mild cerebral atrophy in chronic stage, etc. There were some cases of mild head injury in which CT findings were normal while EEG examination revealed abnormality. Also in some cases, x-ray study demonstrated linear skull fracture which CT failed to show. These conventional techniques could be still remained as useful adjunct aid in diagnosis of head injury. CT findings of cases of cerebral contusion in their acute stage were divided as follows; normal, low density, small ventricle and ventricular and/or cisternal hemorrhage, frequency of incidence being 38, 17, 22, 11% respectively. These findings were invariably converted to cerebral atrophy from 10 days to 2 months after the impacts. In the cases with intracranial hematoma revealed by CT, only 32% of them showed clinical signs of Araki's type IV in their acute stage and 63% of them showed no neurological defects, that is Araki's type I and II. A case of extreme diffuse cerebral atrophy which followed acute subdural hematoma caused by tear of bridging veins without cortical contusion was presented. (author)

  2. The exploding head syndrome.

    Science.gov (United States)

    Green, M W

    2001-06-01

    This article reviews the features of an uncommon malady termed "the exploding head syndrome." Sufferers describe terrorizing attacks of a painless explosion within their head. Attacks tend to occur at the onset of sleep. The etiology of attacks is unknown, although they are considered to be benign. Treatment with clomipramine has been suggested, although most sufferers require only reassurance that the spells are benign in nature.

  3. Nanomedicines for inflammatory arthritis : head-to-head comparison of glucocorticoid-containing polymers, micelles, and liposomes

    NARCIS (Netherlands)

    Quan, Lingdong; Zhang, Yijia; Crielaard, Bart J; Dusad, Anand; Lele, Subodh M; Rijcken, Cristianne J F; Metselaar, Josbert M; Kostková, Hana; Etrych, Tomáš; Ulbrich, Karel; Kiessling, Fabian; Mikuls, Ted R; Hennink, Wim E; Storm, Gert; Lammers, Twan; Wang, Dong

    2014-01-01

    As an emerging research direction, nanomedicine has been increasingly utilized to treat inflammatory diseases. In this head-to-head comparison study, four established nanomedicine formulations of dexamethasone, including liposomes (L-Dex), core-cross-linked micelles (M-Dex), slow releasing polymeric

  4. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.

    Science.gov (United States)

    Gu, Wenbo; O'Connor, Daniel; Nguyen, Dan; Yu, Victoria Y; Ruan, Dan; Dong, Lei; Sheng, Ke

    2018-04-01

    Intensity-Modulated Proton Therapy (IMPT) is the state-of-the-art method of delivering proton radiotherapy. Previous research has been mainly focused on optimization of scanning spots with manually selected beam angles. Due to the computational complexity, the potential benefit of simultaneously optimizing beam orientations and spot pattern could not be realized. In this study, we developed a novel integrated beam orientation optimization (BOO) and scanning-spot optimization algorithm for intensity-modulated proton therapy (IMPT). A brain chordoma and three unilateral head-and-neck patients with a maximal target size of 112.49 cm 3 were included in this study. A total number of 1162 noncoplanar candidate beams evenly distributed across 4π steradians were included in the optimization. For each candidate beam, the pencil-beam doses of all scanning spots covering the PTV and a margin were calculated. The beam angle selection and spot intensity optimization problem was formulated to include three terms: a dose fidelity term to penalize the deviation of PTV and OAR doses from ideal dose distribution; an L1-norm sparsity term to reduce the number of active spots and improve delivery efficiency; a group sparsity term to control the number of active beams between 2 and 4. For the group sparsity term, convex L2,1-norm and nonconvex L2,1/2-norm were tested. For the dose fidelity term, both quadratic function and linearized equivalent uniform dose (LEUD) cost function were implemented. The optimization problem was solved using the Fast Iterative Shrinkage-Thresholding Algorithm (FISTA). The IMPT BOO method was tested on three head-and-neck patients and one skull base chordoma patient. The results were compared with IMPT plans created using column generation selected beams or manually selected beams. The L2,1-norm plan selected spatially aggregated beams, indicating potential degeneracy using this norm. L2,1/2-norm was able to select spatially separated beams and achieve

  5. Data assimilation in integrated hydrological modeling using ensemble Kalman filtering

    DEFF Research Database (Denmark)

    Rasmussen, Jørn; Madsen, H.; Jensen, Karsten Høgh

    2015-01-01

    Groundwater head and stream discharge is assimilated using the ensemble transform Kalman filter in an integrated hydrological model with the aim of studying the relationship between the filter performance and the ensemble size. In an attempt to reduce the required number of ensemble members...... and estimating parameters requires a much larger ensemble size than just assimilating groundwater head observations. However, the required ensemble size can be greatly reduced with the use of adaptive localization, which by far outperforms distance-based localization. The study is conducted using synthetic data...

  6. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    Science.gov (United States)

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to

  7. Visual-Auditory Integration during Speech Imitation in Autism

    Science.gov (United States)

    Williams, Justin H. G.; Massaro, Dominic W.; Peel, Natalie J.; Bosseler, Alexis; Suddendorf, Thomas

    2004-01-01

    Children with autistic spectrum disorder (ASD) may have poor audio-visual integration, possibly reflecting dysfunctional "mirror neuron" systems which have been hypothesised to be at the core of the condition. In the present study, a computer program, utilizing speech synthesizer software and a "virtual" head (Baldi), delivered speech stimuli for…

  8. Anaphylaxis Due to Head Injury

    Directory of Open Access Journals (Sweden)

    Bruner, Heather C.

    2015-05-01

    Full Text Available Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury. [West J Emerg Med. 2015;16(3:435–437.

  9. Head first rails a learner's companion to ruby on rails

    CERN Document Server

    Griffiths, David

    2009-01-01

    Ready to transport your web applications into the Web 2.0 era? Head First Rails takes your programming -- and productivity -- to the max. You'll learn everything from the fundamentals of Rails scaffolding to building customized interactive web apps using Rails' rich set of tools and the MVC framework. By the time you're finished, you'll have learned more than just another web framework. You'll master database interactions, integration with Ajax and XML, rich content, and even dynamic graphing of your data -- all in a fraction of the time it takes to build the same apps with Java, PHP, ASP.NE

  10. Surgical Management of Perineural Spread of Head and Neck Cancers.

    Science.gov (United States)

    Solares, C Arturo; Mason, Eric; Panizza, Benedict J

    2016-04-01

    The surgical management of perineural spread of head and neck cancers has become an integral part in the contemporary treatment of this pathology. We now understand that tumour spreads within the epineurium and in a continuous fashion. We also can rely on the accuracy of magnetic resonance neurography in detecting and defining the extent of disease. With modern skull base techniques and a greater understanding of the anatomy in this region, specific operations can be designed to help eradicate disease. We review the current approaches and techniques used that enable us to better obtain tumour free margins and hence improve survival.

  11. Head Injuries

    Science.gov (United States)

    ... a severe blow to the head can still knock the brain into the side of the skull ... following certain precautions and taking a break from sports and other activities that make symptoms worse. Playing ...

  12. Debris interactions in reactor vessel lower plena during a severe accident. II. Integral analysis

    International Nuclear Information System (INIS)

    Suh, K.Y.; Henry, R.E.

    1996-01-01

    For pt.I see ibid., p.147-63, 1996. The integral physico-numerical model for the reactor vessel lower head response has been exercised for the TMI-2 accident and possible severe accident scenarios in PWR and BWR designs. The proposed inherent cooling mechanism of the reactor material creep and subsequent water ingression implemented in this predictive model provides a consistent representation of how the debris was finally cooled in the TMI-2 accident and how the reactor lower head integrity was maintained during the course of the incident. It should be recalled that in order for this strain to occur, the vessel lower head had to achieve temperatures in excess of 1000 C. This is certainly in agreement with the temperatures determined by metallographic examinations during the TMI-2 vessel inspection program. The integral model was also applied to typical PWR and BWR lower plena with and without structures under pressurized conditions spanning the first relocation of core material to the reactor vessel failure due to creep without recovery actions. The design application results are presented with particular attention being focused on water ingression into the debris bed through the gap formed between the debris and the vessel wall. As an illustration of the accident management application, the lower plenum with structures was recovered after an extensive amount of creep had damaged the vessel wall. The computed lower head temperatures were found to be significantly lower (by more than 300 K in this particular example) with recovery relative to the case without recovery. This clearly demonstrates the potential for in-vessel cooling of the reactor vessel without a need to externally submerge the lower head should such a severe accident occur as core melting and relocation. (orig.)

  13. [The family. The poorest households with female heads].

    Science.gov (United States)

    Acosta Diaz, F

    1992-01-01

    Data from the household questionnaire of the 1987 Mexican Fertility and Health Survey were the basis for an analysis of the characteristics of households headed by women. 14.1% of households were headed by women in 1987, of which 14% were in rural and 86% in urban areas. 41.9% of the households headed by women contained only a woman and her children. Child care responsibilities are the main determinant of discrimination in the labor market for these women and oblige them to accept jobs that are not adequately paid. The social disadvantage of households headed by women is also related to their age and marital and educational status. Among male and female household heads respectively, 16.3% and 36.5% were over age 60, 16.4% and 27.5% were illiterate, and 92.7% and 8.4% were married or in union. 15.5% of the female heads were single, 24.7% were divorced or separated, and 51.4% were widows. Among employed female household heads, 49.2% were salaried, 36.5% were self-employed, and 10.1% were domestic workers. 63.8% of female and 46.3% of male household heads earned one minimum salary or less per month. The average size of households headed by women was 3.9 members, compared to 5.4 for households headed by men.

  14. Head trauma in female professional wrestlers

    International Nuclear Information System (INIS)

    Nomoto, Jun; Seiki, Yoshikatsu; Nemoto, Masaaki

    2007-01-01

    The clinical characteristics of head trauma were evaluated in 18 wrestlers belonging to a female professional wrestling organization, 13 regular members and five trainees aged 15-34 years. Medical examinations for head trauma were performed in all wrestlers, and wrestlers treated at our emergency outpatient department were clinically evaluated. In addition, the relationships of head trauma with duration of the wrestling career of 1-16 years (mean 8 years) in the regular members, and less than 1 year in the five trainees, and body mass index (BMI) of 21.0-32.0 in the 16 subjects, excluding two trainees, was evaluated. Chronic symptoms were noted in four of the 18 wrestlers with long wrestling careers (16 years in 1, 13 years in 1, and 5 years in 2). Three wrestlers with symptoms immediately after head trauma showed recurrent retrograde amnesia and had low BMI (21.6, 21.6, and 23.1). Five wrestlers were treated at our emergency outpatient clinic, three required hospitalization and two showed intracranial traumatic changes on computed tomography (acute subdural hematoma in 1 and diffuse brain swelling in 1). Head trauma in female professional wrestlers is associated with longer wrestling career and low BMI. Periodic medical examinations are recommended to monitor for signs of head trauma. (author)

  15. Posterior-only spinal fusion without rib head resection for treating type I neurofibromatosis with intra-canal rib head dislocation

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2013-12-01

    Full Text Available OBJECTIVES: Patients with Type I neurofibromatosis scoliosis with intra-canal rib head protrusion are extremely rare. Current knowledge regarding the diagnosis and treatment for this situation are insufficient. The purpose of this study is to share our experience in the diagnosis and surgical treatments for such unique deformities. METHODS: Six patients with Type I neurofibromatosis scoliosis with rib head dislocation into the spinal canal were diagnosed at our institution. Posterior instrumentation and spinal fusion without intra-canal rib head resection via a posterior-only approach was performed for deformity correction and rib head extraction. The efficacy and outcomes of the surgery were evaluated by measurements before, immediately and 24 months after the surgery using the following parameters: coronal spinal Cobb angle, apex rotation and kyphosis of the spine and the intra-canal rib head position. Post-operative complications, surgery time and blood loss were also evaluated. RESULTS: Patients were followed up for at least 24 months post-operatively. The three dimensional spinal deformity was significantly improved and the intra-canal rib head was significantly extracted from the canal immediately after the surgery. At follow-up 24 months after surgery, solid fusions were achieved along the fusion segments, and the deformity corrections and rib head positions were well maintained. There were no surgery-related complications any time after the surgery. CONCLUSIONS: Systematic examinations are needed to identify patients with Type I neurofibromatosis scoliosis with rib head dislocation into the canal who can be treated by posterior-only spinal fusion without rib head resection.

  16. A customized head and neck support system

    International Nuclear Information System (INIS)

    Bentel, Gunilla C.; Marks, Lawrence B.; Sherouse, George W.; Spencer, David P.

    1995-01-01

    Purpose: To describe a customized head and neck immobilization system for patients receiving radiotherapy including a head support that conforms to the posterior contour of the head and neck. Methods: The system includes a customized headrest to support the posterior head and neck. This is fixed to a thermoplastic face mask that molds to the anterior head/face contours. The shape of these customized head and neck supports were compared to 'standard' supports. Results: This system is comfortable for the patients and appears to be effective in reproducing the setup of the treatment. Conclusions: The variability in the size and shape of the customized posterior supports exceeded that of 'standard' headrests. It is our clinical impression that the customized supports improve reproducibility and are now a standard part of our immobilization system. The quantitative analysis of the customized headrests and some commonly used 'standard' headrests suggests that the customized supports are better able to address variabilities in patient shape

  17. Ulnar nerve entrapment complicating radial head excision

    Directory of Open Access Journals (Sweden)

    Kevin Parfait Bienvenu Bouhelo-Pam

    Full Text Available Introduction: Several mechanisms are involved in ischemia or mechanical compression of ulnar nerve at the elbow. Presentation of case: We hereby present the case of a road accident victim, who received a radial head excision for an isolated fracture of the radial head and complicated by onset of cubital tunnel syndrome. This outcome could be the consequence of an iatrogenic valgus of the elbow due to excision of the radial head. Hitherto the surgical treatment of choice it is gradually been abandoned due to development of radial head implant arthroplasty. However, this management option is still being performed in some rural centers with low resources. Discussion: The radial head plays an important role in the stability of the elbow and his iatrogenic deformity can be complicated by cubital tunnel syndrome. Conclusion: An ulnar nerve release was performed with favorable outcome. Keywords: Cubital tunnel syndrome, Peripheral nerve palsy, Radial head excision, Elbow valgus

  18. Behavioral integrity for safety, priority of safety, psychological safety, and patient safety : a team-level study

    NARCIS (Netherlands)

    Leroy, H.; Dierynck, B.; Anseel, F.; Simons, T.; Halbesleben, J.R.; McCaughey, D.; Savage, G.T.; Sels, L.

    2012-01-01

    This article clarifies how leader behavioral integrity for safety helps solve follower's double bind between adhering to safety protocols and speaking up about mistakes against protocols. Path modeling of survey data in 54 nursing teams showed that head nurse behavioral integrity for safety

  19. Closure head for a nuclear reactor

    International Nuclear Information System (INIS)

    Wade, E.E.

    1980-01-01

    A closure head for a nuclear reactor includes a stationary outer ring integral with the reactor vessel with a first rotatable plug disposed within the stationary outer ring and supported from the stationary outer ring by a bearing assembly. A sealing system is associated with the bearing assembly to seal the annulus defined between the first rotatable plug and the stationary outer ring. The sealing system comprises tubular seal elements disposed in the annulus with load springs contacting the tubular seal elements so as to force the tubular seal elements against the annulus in a manner to seal the annulus. The sealing system also comprises a sealing fluid which is pumped through the annulus and over the tubular seal elements causing the load springs to compress thereby reducing the friction between the tubular seal elements and the rotatable components while maintaining a gas-tight seal therebetween

  20. Head Rotation Detection in Marmoset Monkeys

    Science.gov (United States)

    Simhadri, Sravanthi

    Head movement is known to have the benefit of improving the accuracy of sound localization for humans and animals. Marmoset is a small bodied New World monkey species and it has become an emerging model for studying the auditory functions. This thesis aims to detect the horizontal and vertical rotation of head movement in marmoset monkeys. Experiments were conducted in a sound-attenuated acoustic chamber. Head movement of marmoset monkey was studied under various auditory and visual stimulation conditions. With increasing complexity, these conditions are (1) idle, (2) sound-alone, (3) sound and visual signals, and (4) alert signal by opening and closing of the chamber door. All of these conditions were tested with either house light on or off. Infra-red camera with a frame rate of 90 Hz was used to capture of the head movement of monkeys. To assist the signal detection, two circular markers were attached to the top of monkey head. The data analysis used an image-based marker detection scheme. Images were processed using the Computation Vision Toolbox in Matlab. The markers and their positions were detected using blob detection techniques. Based on the frame-by-frame information of marker positions, the angular position, velocity and acceleration were extracted in horizontal and vertical planes. Adaptive Otsu Thresholding, Kalman filtering and bound setting for marker properties were used to overcome a number of challenges encountered during this analysis, such as finding image segmentation threshold, continuously tracking markers during large head movement, and false alarm detection. The results show that the blob detection method together with Kalman filtering yielded better performances than other image based techniques like optical flow and SURF features .The median of the maximal head turn in the horizontal plane was in the range of 20 to 70 degrees and the median of the maximal velocity in horizontal plane was in the range of a few hundreds of degrees per

  1. Subchondral insufficiency fractures of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M.; Cassar-Pullicino, V.N. [Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom); Darby, A.J. [Department of Pathology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom)

    2004-02-01

    The aim of this study was to increase awareness of, and to show the variable clinical and radiological features of, subchondral insufficiency fractures of the femoral head. The clinical and radiological findings in 7 patients with subchondral insufficiency fractures of the femoral head were reviewed retrospectively. The diagnosis was confirmed histologically in 4 patients. Radiographs were performed in all patients, MRI in 5 and scintigraphy in 4 patients. Radiographs showed varying degrees of femoral head collapse in 4 patients. In the remaining 3 patients radiographs showed a normal femoral head, regional osteoporosis and focal sclerosis, respectively. Magnetic resonance imaging showed a low-signal band on T1- and T2-weighted images in the subchondral bone adjacent or parallel to the articular surface associated with bone marrow oedema. Scintigraphy showed increased uptake in the femoral head. Insufficiency fractures of the femoral head are easily overlooked or confused with avascular necrosis and, when there is significant joint destruction, osteoarthritis. Unsuspected insufficiency fracture of the femoral head can lead to significant and rapid loss of bone stock in osteoporotic patients waiting for arthroplasty for osteoarthritis. Increased awareness of this condition will hopefully lead to earlier diagnosis and a successful outcome of conservative treatment. (orig.)

  2. Head-Impact–Measurement Devices: A Systematic Review

    Science.gov (United States)

    O'Connor, Kathryn L.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.

    2017-01-01

    Context: With an estimated 3.8 million sport- and recreation-related concussions occurring annually, targeted prevention and diagnostic methods are needed. Biomechanical analysis of head impacts may provide quantitative information that can inform both prevention and diagnostic strategies. Objective: To assess available head-impact devices and their clinical utility. Data Sources: We performed a systematic search of the electronic database PubMed for peer-reviewed publications, using the following phrases: accelerometer and concussion, head impact telemetry, head impacts and concussion and sensor, head impacts and sensor, impact sensor and concussion, linear acceleration and concussion, rotational acceleration and concussion, and xpatch concussion. In addition to the literature review, a Google search for head impact monitor and concussion monitor yielded 15 more devices. Study Selection: Included studies were performed in vivo, used commercially available devices, and focused on sport-related concussion. Data Extraction: One author reviewed the title and abstract of each study for inclusion and exclusion criteria and then reviewed each full-text article to confirm inclusion criteria. Controversial articles were reviewed by all authors to reach consensus. Data Synthesis: In total, 61 peer-reviewed articles involving 4 head-impact devices were included. Participants in boxing, football, ice hockey, soccer, or snow sports ranged in age from 6 to 24 years; 18% (n = 11) of the studies included female athletes. The Head Impact Telemetry System was the most widely used device (n = 53). Fourteen additional commercially available devices were presented. Conclusions: Measurements collected by impact monitors provided real-time data to estimate player exposure but did not have the requisite sensitivity to concussion. Proper interpretation of previously reported head-impact kinematics across age, sport, and position may inform future research and enable staff clinicians

  3. Kinematics of a Head-Neck Model Simulating Whiplash

    Science.gov (United States)

    Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan

    2008-01-01

    A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that…

  4. Hydro-thermal power flow scheduling accounting for head variations

    International Nuclear Information System (INIS)

    El-Hawary, M.E.; Ravindranath, K.M.

    1992-01-01

    In this paper the authors treat the problem of optimal economic operation of hydrothermal electric power systems with variable head hydro plants employing the power flow equations to represent the network. Newton's method is used to solve the problem for a number of test systems. A comparison with solutions with fixed head is presented. In general the optimal schedule requires higher slack bus and thermal power generation and cost in the case of variable head hydro plant than that required by the fixed head hydro plant in all demand periods. Correspondingly, the hydro generation is less in the case of variable head hydro plant compared to fixed head hydro plant. A negligible difference in voltage magnitudes in all the time intervals, but it is observed that slightly higher voltages occur in the case of the fixed head hydro plant. Higher power and energy losses occur in the case of variable head hydro plants compared to the fixed head hydro plants

  5. Public knowledge of head and neck cancer.

    LENUS (Irish Health Repository)

    O'Connor, T E

    2010-04-01

    Studies show 60% of patients with newly diagnosed Head & Neck Squamous Cell Cancer in Ireland, present with advanced disease. A poor level of knowledge and awareness among the public of Head & Neck Cancer, is an important consideration in the often delayed presentation for medical attention in many of these cases. Our study surveyed 200 members of the public to assess their knowledge and awareness of Head & Neck Cancer. One hundred and forty (70%) of respondents had never encountered the term "Head & Neck Cancer". One hundred and forty six (73%) failed to identify excessive alcohol consumption as a risk factor. Less than 100 (50%) would have concern about persisting hoarseness or a prolonged oral ulcer. An urgent need exists to raise awareness of Head & Neck Cancer among the public in Ireland.

  6. Heads Up to High School Sports

    Science.gov (United States)

    ... submit" value="Submit" /> HEADS UP to School Sports Recommend on Facebook Tweet Share Compartir To help ... organizations, developed the HEADS UP: Concussion in School Sports initiative and materials. Specific Concussion Information for... Coaches ...

  7. Head first Ajax

    CERN Document Server

    Riordan, Rebecca M

    2008-01-01

    Ajax is no longer an experimental approach to website development, but the key to building browser-based applications that form the cornerstone of Web 2.0. Head First Ajax gives you an up-to-date perspective that lets you see exactly what you can do -- and has been done -- with Ajax. With it, you get a highly practical, in-depth, and mature view of what is now a mature development approach. Using the unique and highly effective visual format that has turned Head First titles into runaway bestsellers, this book offers a big picture overview to introduce Ajax, and then explores the use of ind

  8. Fully automated whole-head segmentation with improved smoothness and continuity, with theory reviewed.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Individualized current-flow models are needed for precise targeting of brain structures using transcranial electrical or magnetic stimulation (TES/TMS. The same is true for current-source reconstruction in electroencephalography and magnetoencephalography (EEG/MEG. The first step in generating such models is to obtain an accurate segmentation of individual head anatomy, including not only brain but also cerebrospinal fluid (CSF, skull and soft tissues, with a field of view (FOV that covers the whole head. Currently available automated segmentation tools only provide results for brain tissues, have a limited FOV, and do not guarantee continuity and smoothness of tissues, which is crucially important for accurate current-flow estimates. Here we present a tool that addresses these needs. It is based on a rigorous Bayesian inference framework that combines image intensity model, anatomical prior (atlas and morphological constraints using Markov random fields (MRF. The method is evaluated on 20 simulated and 8 real head volumes acquired with magnetic resonance imaging (MRI at 1 mm3 resolution. We find improved surface smoothness and continuity as compared to the segmentation algorithms currently implemented in Statistical Parametric Mapping (SPM. With this tool, accurate and morphologically correct modeling of the whole-head anatomy for individual subjects may now be feasible on a routine basis. Code and data are fully integrated into SPM software tool and are made publicly available. In addition, a review on the MRI segmentation using atlas and the MRF over the last 20 years is also provided, with the general mathematical framework clearly derived.

  9. Fully automated whole-head segmentation with improved smoothness and continuity, with theory reviewed.

    Science.gov (United States)

    Huang, Yu; Parra, Lucas C

    2015-01-01

    Individualized current-flow models are needed for precise targeting of brain structures using transcranial electrical or magnetic stimulation (TES/TMS). The same is true for current-source reconstruction in electroencephalography and magnetoencephalography (EEG/MEG). The first step in generating such models is to obtain an accurate segmentation of individual head anatomy, including not only brain but also cerebrospinal fluid (CSF), skull and soft tissues, with a field of view (FOV) that covers the whole head. Currently available automated segmentation tools only provide results for brain tissues, have a limited FOV, and do not guarantee continuity and smoothness of tissues, which is crucially important for accurate current-flow estimates. Here we present a tool that addresses these needs. It is based on a rigorous Bayesian inference framework that combines image intensity model, anatomical prior (atlas) and morphological constraints using Markov random fields (MRF). The method is evaluated on 20 simulated and 8 real head volumes acquired with magnetic resonance imaging (MRI) at 1 mm3 resolution. We find improved surface smoothness and continuity as compared to the segmentation algorithms currently implemented in Statistical Parametric Mapping (SPM). With this tool, accurate and morphologically correct modeling of the whole-head anatomy for individual subjects may now be feasible on a routine basis. Code and data are fully integrated into SPM software tool and are made publicly available. In addition, a review on the MRI segmentation using atlas and the MRF over the last 20 years is also provided, with the general mathematical framework clearly derived.

  10. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Training course: This page has moved Recommend on Facebook Tweet Share Compartir This training course has been ... with HEADS UP & CDC's Injury Center HEADS UP Resources ... HHS/Open USA.gov Top

  11. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1984-12-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training the head was safely removed and stored and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  12. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1985-09-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 (TMI-2) reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training, the head was safely removed and stored; and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  13. Achieving Consensus Through Professionalized Head Nods

    DEFF Research Database (Denmark)

    Oshima, Sae

    2014-01-01

    of nodding in a particular professional-client setting, namely, hair salon interactions. My interest specifically lies in the frequent occurrence of synchronized head nods during the “service-assessment sequence,” where both service provider and customer inspect and determine whether the completed work...... is adequate. I pursue mechanisms of synchronized head nods by revealing exactly how participants collaborate in producing a nod, and how their verbal actions may at times be designed accordingly. In doing so, the study provides insight into what consensus may look like at service encounters in Japan......While the interactional functions of head nodding in everyday Japanese conversation have been frequently studied, a discourse on head nodding as a professional communicative practice has yet to be explored. With the method of multimodal conversation analysis, the current study examines the role...

  14. Health Coordination Manual. Head Start Health Services.

    Science.gov (United States)

    Administration for Children, Youth, and Families (DHHS), Washington, DC. Head Start Bureau.

    Part 1 of this manual on coordinating health care services for Head Start children provides an overview of what Head Start health staff should do to meet the medical, mental health, nutritional, and/or dental needs of Head Start children, staff, and family members. Offering examples, lists, action steps, and charts for clarification, part 2…

  15. Measurement of flow inside a vacuum cleaner head

    Science.gov (United States)

    Iguchi, Ryotaro; Ban, Hisataka; Sakakibara, Jun

    2017-11-01

    Vacuum cleaner head with rotating brushes is widely used as a home appliance. Although it efficiently collects dusts from the floor, flow field of the air and motion of the dust inside the head have not been fully investigated. In this study, we performed 3D-PIV (particle tracking velocimetry) measurement of velocity field inside the head. Water was used as working fluid, which allows a use of fluorescent particle to reduce unwanted reflection from the brushes and inner surface of the head. Mean velocity field and turbulence statistics in the head with and without the brush will be presented.

  16. "Head up and eyes out" advances in head mounted displays capabilities

    Science.gov (United States)

    Cameron, Alex

    2013-06-01

    There are a host of helmet and head mounted displays, flooding the market place with displays which provide what is essentially a mobile computer display. What sets aviators HMDs apart is that they provide the user with accurate conformal information embedded in the pilots real world view (see through display) where the information presented is intuitive and easy to use because it overlays the real world (mix of sensor imagery, symbolic information and synthetic imagery) and enables them to stay head up, eyes out, - improving their effectiveness, reducing workload and improving safety. Such systems are an enabling technology in the provision of enhanced Situation Awareness (SA) and reducing user workload in high intensity situations. Safety Is Key; so the addition of these HMD functions cannot detract from the aircrew protection functions of conventional aircrew helmets which also include life support and audio communications. These capabilities are finding much wider application in new types of compact man mounted audio/visual products enabled by the emergence of new families of micro displays, novel optical concepts and ultra-compact low power processing solutions. This papers attempts to capture the key drivers and needs for future head mounted systems for aviation applications.

  17. Head of detector for multi-element analysis

    International Nuclear Information System (INIS)

    Frynta, Z.

    1983-01-01

    The detector head mounted on the scintillation counter consists of a hollow hexagonal rotary support axially arranged with the photomultiplier of the scintillation counter. In the walls of the hexagonal rotary support there are openings in which are inserted absorption filters. The mounting of the absorption filters on the rotary support allows the analysis of a greater number of elements without the dismantling of the head and the replacement of filters. The suitable geometry of the head is retained so that it is possible to insert the head into the hollows similarly as the scintillation counter. (J.P.)

  18. Handling and carrying head for nuclear fuel assemblies and installation including this head

    International Nuclear Information System (INIS)

    Artaud, R.; Cransac, J.P.; Jogand, P.

    1986-01-01

    The present invention proposes a handling and carrying head ensuring efficiently the cooling of the nuclear fuel asemblies it transports so that any storage in liquid metal in a drum within or adjacent the reactor vessel is suppressed. The invention claims also a nuclear fuel handling installation including the head; it allows a longer time between loading and unloading campaigns and the space surrounding the reactor vessel keeps free without occupying a storage zone within the vessel [fr

  19. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do I view different ... 6348 Email CDC-INFO U.S. Department of Health & Human Services HHS/Open USA.gov Top

  20. Low head hydro market assessment : main report : vol. 1

    International Nuclear Information System (INIS)

    2008-03-01

    Hydroelectric power is a predictable renewable energy source that produces no greenhouse gases (GHGs) and has low maintenance costs. In addition to river resources, low head hydro is available in sluice gates, irrigation canals, drinking water pressure release valves, and municipal wastewater outfalls. Canada's potential for low head hydro has been estimated at 5000 MW at 2000 different sites across the country. Sites of up to 50 MW have been identified in Ontario and Manitoba. This study performed a market assessment on low head hydro developments. Available and emerging technologies for developing low head hydro were identified. The economics of low head hydro in Canada were explored, and barriers to low head hydro development were identified. Strategies to promote low head hydro development were also explored, and the impact of different incentive types on the low head hydropower market were estimated using a simple economic model. It was concluded that a reduced, streamlined, and standardized environmental assessment process will significantly benefit low head hydro development in Canada. 5 refs., 14 tabs., 17 figs

  1. [Assessment of functioning in patients with head and neck cancer based on the international classification of functioning, disability and health (ICF)].

    Science.gov (United States)

    Tschiesner, U

    2011-09-01

    The article approaches with the question how preservation of function after treatment of head and neck cancer (HNC) can be defined and measured across treatment approaches. On the basis of the "International Classification of Functioning, Disability and Health (ICF)" a series of efforts are summarized how all relevant aspects of the interdisciplinary team can be integrated into a common concept.Different efforts on the development, validation and implementation of ICF Core Sets for head and neck cancer (ICF-HNC) are discussed. The ICF-HNC covers organ-based problems with food ingestion, breathing, and speech, as well as psychosocial difficulties.Relationships between the ICF-HNC and well-established outcome measures are illustrated. This enables the user to integrate different aspects of functional outcome into a consolidated approach towards preservation/rehabilitation of functioning after HNC - applicable for a variety of treatment-approaches and health-professions. George Thieme Verlag KG Stuttgart · New York.

  2. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Submit Button Connect with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do ... Page last updated: April 24, 2017 Content source: Centers for Disease Control and Prevention , National Center for ...

  3. New Dimensions in Movement and Fitness through Integration

    Science.gov (United States)

    Dean, Blair

    2005-01-01

    In this article, the author presents a number of ways to integrate academic content with physical activities. Among the activities are: (1) Paint the Alphabet, where students use different body parts (arms, legs, and head) as large paint brushes to paint the entire alphabet on an imaginary canvas; (2) Sequence Race, where students are placed into…

  4. NUMERICAL ANALYSIS OF INFLUENCE OF EXOGENOUS FIRE IN DOG HEADING ON PARAMETERS OF THE AIR STREAM FLOWING THROUGH THIS HEADING

    Directory of Open Access Journals (Sweden)

    Magdalena TUTAK

    2014-04-01

    Full Text Available Flow of ventilation air stream through the dog heading with a fire centre is the flow with complex character, during which as a result of emission of fire gases into the mining atmosphere, there occur to disturbances of its flow. In the paper there is presented a numerical analysis of an influence of exogenous fire in a dog heading, on the parameters of the ventilation air stream flowing through this heading. Modeling tests were carried out with a use of ANSYS software, basing on the Finite Volume Method. For the made assumptions, there were determined physical parameters of air stream flowing through the heading with a fire centre, and also changes in mass fraction of gases in this stream during its flow through the analyzed heading: oxygen, carbon monoxide and carbon dioxide. As a result of performed analysis over the fire centre, the local increase of velocity and temperature and violent decrease of static pressure were recorded. Model of heading presented in the paper gives possibilities for development, and then the analysis of more complicated problems in a range of ventilation of mining headings.

  5. Navigating Motherhood and the Role of the Head Athletic Trainer in the Collegiate Setting

    Science.gov (United States)

    Mazerolle, Stephanie M.; Eason, Christianne M.

    2016-01-01

    Context:  Motherhood has been identified as a barrier to the head athletic trainer (AT) position. Role models have been cited as a possible facilitator for increasing the number of women who pursue and maintain this role in the collegiate setting. Objective:  To examine the experiences of female ATs balancing motherhood and head AT positions in the National Collegiate Athletic Association Division II and III and National Association of Intercollegiate Athletics settings. Design:  Qualitative study. Setting:  National Collegiate Athletic Association Divisions II and III and National Association of Intercollegiate Athletics. Patients or Other Participants:  A total of 22 female head ATs (average age = 40 ± 8 years) who were married with children completed our study. Our participants had been certified for 15.5 ± 7.5 years and in their current positions as head ATs for 9 ± 8 years. Data Collection and Analysis:  We conducted online interviews with all participants. Participants journaled their reflections on a series of open-ended questions pertaining to their experiences as head ATs. Data were analyzed following a general inductive approach. Credibility was confirmed through peer review and researcher triangulation. Results:  We identified 3 major contributors to work-life conflict. Two speak to organizational influences on conflict: work demands and time of year. The role of motherhood, which was more of a personal contributor, also precipitated conflict for our ATs. Four themes emerged as work-life balance facilitators: planning, attitude and perspective, support networks, and workplace integration. Support was defined at both the personal and professional levels. Conclusions:  In terms of the organization, our participants juggled long work hours, travel, and administrative tasks. Individually and socioculturally, they overcame their guilt and their need to be present and an active part of the parenting process. These mothers demonstrated the

  6. Theory of the interaction of flat sensing organ with the head of the sugar beet root

    Directory of Open Access Journals (Sweden)

    Volodymyr Bulgakov

    2017-12-01

    sensing organ with a fixed sugar beet root head. There was also selected and arranged the axis of coordinates, and determined the active forces and angle parameters. Using the basic law of dynamics there was made up a new system of differential equations and the integration of which has made it possible to find the laws of variation of the speed of movement and of the movement of the flat passive sensing organ on the head of sugar beet root head at the beginning of the contact. After determining the initial values of force and design parameters it is possible to solve them on PC to optimise kinematic and structural parameters of the sensing mechanism.

  7. Head injuries in snowboarders compared with head injuries in skiers. A prospective analysis of 1076 patients from 1994 to 1999 in Niigata, Japan.

    Science.gov (United States)

    Fukuda, O; Takaba, M; Saito, T; Endo, S

    2001-01-01

    We investigated snowboarding-related head injury cases and skiing-related head injury cases during five ski seasons at one resort area. There were 634 snowboarding-related head injuries and 442 skiing-related head injuries. The number of snowboarding head injuries increased rapidly over the study period. More male snowboarders than female snowboarders suffered head injuries. For both snowboarders and skiers, head injuries frequently occurred on the easy and middle slopes. Falls were the most frequent causes of injury in both groups. Jumping was a more frequent cause of injury in the snowboarders (30%) than in the skiers (2.5%). Injury to the occipital region predominated in the snowboarders as compared with the skiers. There were 49 organic lesions in 37 snowboarders and 46 organic lesions in 33 skiers. Subdural hematoma was frequent in the snowboarding head injury group, and fracture was frequent in the skiing head injury group compared with the snowboarding group (not significant). Subdural hematoma was likely to be caused by a fall rather than by a collision, and bone fracture was likely to be caused by a collision rather than by a fall. Four snowboarders and one skier died as a result of their head injuries. Our data suggest that snowboarding head injuries may be prevented by protection of the occipital region and refraining from jumping by beginners.

  8. Accelerating image reconstruction in dual-head PET system by GPU and symmetry properties.

    Directory of Open Access Journals (Sweden)

    Cheng-Ying Chou

    Full Text Available Positron emission tomography (PET is an important imaging modality in both clinical usage and research studies. We have developed a compact high-sensitivity PET system that consisted of two large-area panel PET detector heads, which produce more than 224 million lines of response and thus request dramatic computational demands. In this work, we employed a state-of-the-art graphics processing unit (GPU, NVIDIA Tesla C2070, to yield an efficient reconstruction process. Our approaches ingeniously integrate the distinguished features of the symmetry properties of the imaging system and GPU architectures, including block/warp/thread assignments and effective memory usage, to accelerate the computations for ordered subset expectation maximization (OSEM image reconstruction. The OSEM reconstruction algorithms were implemented employing both CPU-based and GPU-based codes, and their computational performance was quantitatively analyzed and compared. The results showed that the GPU-accelerated scheme can drastically reduce the reconstruction time and thus can largely expand the applicability of the dual-head PET system.

  9. Development of a unique phantom to assess dose error of metal artifact in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Young; Kang, Sang Won; Suh, Tae Suk [Dept. of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Jeong Woo [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Park, Ji Yeon [Dept. of Pediatrics and Molecular Imaging Program at Stanford, Stanford University, Stanford (United States)

    2016-04-15

    The artifacts not only blur the CT images and lead to inaccuracies in diagnosis, but also make the delineation of anatomical structures intractable, which is important in image-guided intervention procedures. These artifacts obscure the underlying anatomy, leading to uncertainty in the delineation of the target volumes and compromising the integrity of the density representation that is crucial for accurate dose calculation. Because head and neck cancer patients tend to be over the age of 50 years, they constitute a group likely to have dental prostheses. This kind of side effects considerably disturbs the therapeutic procedure. Radiation scatter from high atomic number (Z) materials is established to cause both soft tissue and bony complications in the oral cavity, making scattered radiation an important factor in head and neck region radiotherapy planning. In this study, we carried out theoretical analysis of the metal artifact, that is, streak artifact and dark artifact, and also critical analysis of dosimetric effect which cause by dental implants in CT images of head and neck cancer patients with the genuine teeth and implants inserted humanoid phantom. The phantom provides a unique and useful tool in head and neck dosimetry research. It can be used in the development of new imaging instrumentation, image acquisition strategies, and image processing and reconstruction methods.

  10. Late effects of radiation therapy in the head and neck region

    International Nuclear Information System (INIS)

    Cooper, Jay S.; Fu, Karen; Marks, James; Silverman, Sol

    1995-01-01

    The head and neck region is composed of numerous structures, each with an inherent response to radiation that is largely governed by the presence or absence of mucosa, salivary glands, or specialized organs within that site. Irradiated mucocutaneous tissues demonstrate increased vascular permeability that leads to fibrin deposition, subsequent collagen formation, and eventual fibrosis. Irradiated salivary tissue degenerates after relatively small doses, leading to markedly diminished salivary output. This, in turn, effects the teeth by promoting dental decay which, in turn, effects the integrity of the mandible. Details of these changes are presented, including their pathophysiology, clinical syndromes, and potential treatment

  11. Infrared Non-Contact Head Sensor for Control of Wheelchair Movements

    DEFF Research Database (Denmark)

    Christensen, Henrik Vie; Garcia, Juan Carlos

    2005-01-01

    This paper presents a new human-machine interface for controlling a wheelchair by head movements. The position of the head is determined by use of infrared sensors, with no parts attached to the head of the user. The placement of the infrared sensors are behind the head of the user, so that the f......This paper presents a new human-machine interface for controlling a wheelchair by head movements. The position of the head is determined by use of infrared sensors, with no parts attached to the head of the user. The placement of the infrared sensors are behind the head of the user, so...

  12. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  13. Effects of Soccer Heading on Brain Structure and Function

    Science.gov (United States)

    Rodrigues, Ana Carolina; Lasmar, Rodrigo Pace; Caramelli, Paulo

    2016-01-01

    Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered as an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of 6–12 incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years, some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the establishment of safety

  14. Effects of soccer heading on brain structure and function

    Directory of Open Access Journals (Sweden)

    Ana Carolina Oliveira Rodrigues

    2016-03-01

    Full Text Available Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of six to twelve incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the

  15. 49 CFR 214.113 - Head protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Head protection. 214.113 Section 214.113 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... conform to the national consensus standards for industrial head protection (American National Standards...

  16. Head and Neck Cancer—Patient Version

    Science.gov (United States)

    Head and neck cancers include cancers in the larynx (voice box), throat, lips, mouth, nose, and salivary glands. Start here to find information on head and neck cancer treatment in adults and children, causes and prevention, screening, research, and statistics.

  17. The head problem. The organizational significance of segmentation in head development.

    Science.gov (United States)

    Horder, Tim J; Presley, Robert; Slípka, Jaroslav

    2010-01-01

    This review argues for the segmental basis of chordate head organization which, like somite-based segmental organization in the trunk, takes its origin from early mesodermal development. The review builds on, and brings up to date, Goodrich's well-known scheme of head organization. It surveys recent data in support of this scheme and shows how evidence and arguments supposedly in conflict with it can be accommodated. Many of the arguments revolve around matters of methodology; the limitations of older LM, SEM (on which the concept of "somitomeres" is based) and recent molecular evidence (which has sometimes been seen as allocating the central role in head organization to the CNS and the neural crest) are highlighted and shown to explain a number of claims contrary to Goodrich's. We provide (in Part 2) a new, comparative survey of the best available evidence most directly relevant to the Goodrich Bauplan, with a special emphasis on stem chordates. The postotic region has commonly been seen as segmentally organized: the critical issues concern the preotic region. There are many reasons why Goodrich's three preotic segments may become specialized during evolution and why the underlying initial segmental organization may be overridden in later stages during embryonic development; we refer to a number of these. We conclude that the preotic segmental Bauplan is remarkably conserved and most explicitly demonstrated among stem forms, but we also suggest that the concept of the prechordal plate requires careful reexamination. Central to our overall analysis is the importance of the epigenetic nature of embryogenesis; its implications are made clear. Finally we speculate on evolutionary implications for the origin of the head and its specialized features. The review is intended to serve as a resource giving access to references to a wealth of now neglected, older data on anamniote embryology.

  18. Migration from full‐head mask to “open‐face” mask for immobilization of patients with head and neck cancer

    Science.gov (United States)

    Lovelock, D. Michael; Mechalakos, James; Rao, Shyam; Della‐Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-01-01

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an “open‐face” thermoplastic mask was evaluated using video‐based optical surface imaging (OSI) and kilovoltage (kV) X‐ray radiography. A three‐point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real‐time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15 minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open‐face and full‐head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open‐face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real‐time OSI. With the open‐face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre‐/post‐treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask‐locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open‐face and full‐head masks were found to be similar. Most (80%) of the volunteers preferred the open‐face mask to the full‐head mask, while claustrophobic patients could only tolerate the open‐face mask. The open‐face mask is characterized for its immobilization capability and can immobilize patients sufficiently (face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full‐head mask. PACS numbers: 87.19.xj, 87.63.L‐, 87.59.‐e, 87.55.tg, 87.55.‐x PMID:24036878

  19. Integrative miRNA-Gene Expression Analysis Enables Refinement of Associated Biology and Prediction of Response to Cetuximab in Head and Neck Squamous Cell Cancer

    Directory of Open Access Journals (Sweden)

    Loris De Cecco

    2017-01-01

    Full Text Available This paper documents the process by which we, through gene and miRNA expression profiling of the same samples of head and neck squamous cell carcinomas (HNSCC and an integrative miRNA-mRNA expression analysis, were able to identify candidate biomarkers of progression-free survival (PFS in patients treated with cetuximab-based approaches. Through sparse partial least square–discriminant analysis (sPLS-DA and supervised analysis, 36 miRNAs were identified in two components that clearly separated long- and short-PFS patients. Gene set enrichment analysis identified a significant correlation between the miRNA first-component and EGFR signaling, keratinocyte differentiation, and p53. Another significant correlation was identified between the second component and RAS, NOTCH, immune/inflammatory response, epithelial–mesenchymal transition (EMT, and angiogenesis pathways. Regularized canonical correlation analysis of sPLS-DA miRNA and gene data combined with the MAGIA2 web-tool highlighted 16 miRNAs and 84 genes that were interconnected in a total of 245 interactions. After feature selection by a smoothed t-statistic support vector machine, we identified three miRNAs and five genes in the miRNA-gene network whose expression result was the most relevant in predicting PFS (Area Under the Curve, AUC = 0.992. Overall, using a well-defined clinical setting and up-to-date bioinformatics tools, we are able to give the proof of principle that an integrative miRNA-mRNA expression could greatly contribute to the refinement of the biology behind a predictive model.

  20. Darlington NGD fuel handling head eight acceptance program

    International Nuclear Information System (INIS)

    Skelton, P.H.; Sie, T.

    1996-01-01

    Darlington NGD requires eight fuelling machine heads to fuel the four 932 MW reactors. Six heads are used on the three fuelling machine trolleys for normal fuelling operations. A further two heads are required to allow for maintenance and to provide for such reactor face activities as PIPE and CIGAR. Seven heads were successfully delivered to site from the head supplier. During acceptance testing, stalls on the charge tube screw assembly of the eighth and final head prevented its delivery to site. Replacement of the charge tube screw with a spare screw did not alleviate the problem. An in depth series of tests were undertaken at site, at the supplier and at the screw sub-supplier to determine the root cause of the problem. These tests included taking torque measurements under different operating conditions and using different components to assess the effects of the changes on torque levels. An assessment of the effects of changing chemical conditions (particularly crud levels) was also made. To ensure that the results of the testing were well understood, additional torque testing was also completed on a head and screw assembly at site that was known to work well. Based on all of the above series of tests, a recommendation was made to re-machine the charge tube screw(s). The original charge tube screw from Head eight was subsequently returned to the sub-supplier for re-work. Follow-up torque measurements and acceptance testing showed that the screw rework was effective and that Head eight could be successfully delivered to site. This paper focuses on the results of the head/screw test program. Results of the acceptance testing are also discussed. (author). 2 refs., 4 figs

  1. Darlington NGD fuel handling head eight acceptance program

    Energy Technology Data Exchange (ETDEWEB)

    Skelton, P H; Sie, T [Ontario Hydro, Bowmanville (Canada). Darlington Nuclear Generating Station; Pilgrim, J [Canadian General Electric Co. Ltd., Toronto, ON (Canada)

    1997-12-31

    Darlington NGD requires eight fuelling machine heads to fuel the four 932 MW reactors. Six heads are used on the three fuelling machine trolleys for normal fuelling operations. A further two heads are required to allow for maintenance and to provide for such reactor face activities as PIPE and CIGAR. Seven heads were successfully delivered to site from the head supplier. During acceptance testing, stalls on the charge tube screw assembly of the eighth and final head prevented its delivery to site. Replacement of the charge tube screw with a spare screw did not alleviate the problem. An in depth series of tests were undertaken at site, at the supplier and at the screw sub-supplier to determine the root cause of the problem. These tests included taking torque measurements under different operating conditions and using different components to assess the effects of the changes on torque levels. An assessment of the effects of changing chemical conditions (particularly crud levels) was also made. To ensure that the results of the testing were well understood, additional torque testing was also completed on a head and screw assembly at site that was known to work well. Based on all of the above series of tests, a recommendation was made to re-machine the charge tube screw(s). The original charge tube screw from Head eight was subsequently returned to the sub-supplier for re-work. Follow-up torque measurements and acceptance testing showed that the screw rework was effective and that Head eight could be successfully delivered to site. This paper focuses on the results of the head/screw test program. Results of the acceptance testing are also discussed. (author). 2 refs., 4 figs.

  2. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  3. Humeral head size in shoulder arthroplasty

    DEFF Research Database (Denmark)

    Vaesel, M T; Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole

    1998-01-01

    Changes in kinematics after hemiarthroplasty of the glenohumeral joint were investigated in nine cadaveric specimens. During experiments the influence of the humeral head size on glenohumeral kinematics was evaluated. A modular prosthesis with five different head sizes and press-fit stems was use...

  4. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  5. Real-Time Head Pose Estimation on Mobile Platforms

    Directory of Open Access Journals (Sweden)

    Jianfeng Ren

    2010-06-01

    Full Text Available Many computer vision applications such as augmented reality require head pose estimation. As far as the real-time implementation of head pose estimation on relatively resource limited mobile platforms is concerned, it is required to satisfy real-time constraints while maintaining reasonable head pose estimation accuracy. The introduced head pose estimation approach in this paper is an attempt to meet this objective. The approach consists of the following components: Viola-Jones face detection, color-based face tracking using an online calibration procedure, and head pose estimation using Hu moment features and Fisher linear discriminant. Experimental results running on an actual mobile device are reported exhibiting both the real- time and accuracy aspects of the developed approach.

  6. Head movements encode emotions during speech and song.

    Science.gov (United States)

    Livingstone, Steven R; Palmer, Caroline

    2016-04-01

    When speaking or singing, vocalists often move their heads in an expressive fashion, yet the influence of emotion on vocalists' head motion is unknown. Using a comparative speech/song task, we examined whether vocalists' intended emotions influence head movements and whether those movements influence the perceived emotion. In Experiment 1, vocalists were recorded with motion capture while speaking and singing each statement with different emotional intentions (very happy, happy, neutral, sad, very sad). Functional data analyses showed that head movements differed in translational and rotational displacement across emotional intentions, yet were similar across speech and song, transcending differences in F0 (varied freely in speech, fixed in song) and lexical variability. Head motion specific to emotional state occurred before and after vocalizations, as well as during sound production, confirming that some aspects of movement were not simply a by-product of sound production. In Experiment 2, observers accurately identified vocalists' intended emotion on the basis of silent, face-occluded videos of head movements during speech and song. These results provide the first evidence that head movements encode a vocalist's emotional intent and that observers decode emotional information from these movements. We discuss implications for models of head motion during vocalizations and applied outcomes in social robotics and automated emotion recognition. (c) 2016 APA, all rights reserved).

  7. A modification to the Gill-Thomas-Cosman (GTC) head frame for stereotactic radiosurgery of head and neck and cervical spine sites

    International Nuclear Information System (INIS)

    Qian, G.; Hasala, P.; Rashid, H.; Costantino, T.; Cangiane, L.; Lombardi, E.; Arbit, E; Lederman, G.

    1996-01-01

    PURPOSE/OBJECTIVE: Fractionated Stereotactic Radiosurgery (FSR) is used primarily to treat intracranial lesions. Many tumors which arise at or inferior to the base of skull and about the cervical spine area were not amenable to radiosurgery. Presented is a modification to the GTC head frame which permits stereotactic radiosurgery to be directed at head and neck tumors with accurate reproducible precision. MATERIALS AND METHODS: The original GTC head frame has two fixation points; an anterior individualized dental impression and a posterior occipital plate with a mold contoured to the occipital pertuberance. The height of the occipital plate is adjustable in its vertical plane. However, the position of the dental piece is fixed and, therefore, limits treatment to regions superior. Treatment of head and neck and cervical spine tumors has been accomplished with a modification of the dental apparatus. Presented is our new device; a bracket extension which attaches to the dental piece and allows the head frame to be lowered to multiple desired positions. The occipital plate is elevated accordingly to support the occipital pertuberance. The depth helmet is also modified for quality assurance. A Rando phantom was used to test the accuracy and reproducibility of the new equipment. Bracket extensions lowering the head frame by 3 cm and 8 cm, respectively, were tested for accuracy of relocation on the Rando Phantom. Each extension was tested 20 times and for each individual test 18 depth helmet positions were obtained. RESULTS: The standard deviation of the modified head frame for each depth helmet measurement ranged from 0.05 to 0.35mm (mean 0.20) as compared to the standard deviation for the original GTC head frame which was 0.13 to 0.34mm (mean 0.24). The new device maintains the accuracy and reproducibility of the original GTC head frame. CONCLUSION: The GTC relocatable head frame for FSR has been modified to treat tumors of the head and neck and cervical spine sites

  8. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  9. Head orientation prediction: delta quaternions versus quaternions.

    Science.gov (United States)

    Himberg, Henry; Motai, Yuichi

    2009-12-01

    Display lag in simulation environments with helmet-mounted displays causes a loss of immersion that degrades the value of virtual/augmented reality training simulators. Simulators use predictive tracking to compensate for display lag, preparing display updates based on the anticipated head motion. This paper proposes a new method for predicting head orientation using a delta quaternion (DQ)-based extended Kalman filter (EKF) and compares the performance to a quaternion EKF. The proposed framework operates on the change in quaternion between consecutive data frames (the DQ), which avoids the heavy computational burden of the quaternion motion equation. Head velocity is estimated from the DQ by an EKF and then used to predict future head orientation. We have tested the new framework with captured head motion data and compared it with the computationally expensive quaternion filter. Experimental results indicate that the proposed DQ method provides the accuracy of the quaternion method without the heavy computational burden.

  10. Head-head interactions of resting myosin crossbridges in intact frog skeletal muscles, revealed by synchrotron x-ray fiber diffraction.

    Directory of Open Access Journals (Sweden)

    Kanji Oshima

    Full Text Available The intensities of the myosin-based layer lines in the x-ray diffraction patterns from live resting frog skeletal muscles with full thick-thin filament overlap from which partial lattice sampling effects had been removed were analyzed to elucidate the configurations of myosin crossbridges around the thick filament backbone to nanometer resolution. The repeat of myosin binding protein C (C-protein molecules on the thick filaments was determined to be 45.33 nm, slightly longer than that of myosin crossbridges. With the inclusion of structural information for C-proteins and a pre-powerstroke head shape, modeling in terms of a mixed population of regular and perturbed regions of myosin crown repeats along the filament revealed that the myosin filament had azimuthal perturbations of crossbridges in addition to axial perturbations in the perturbed region, producing pseudo-six-fold rotational symmetry in the structure projected down the filament axis. Myosin crossbridges had a different organization about the filament axis in each of the regular and perturbed regions. In the regular region that lacks C-proteins, there were inter-molecular interactions between the myosin heads in axially adjacent crown levels. In the perturbed region that contains C-proteins, in addition to inter-molecular interactions between the myosin heads in the closest adjacent crown levels, there were also intra-molecular interactions between the paired heads on the same crown level. Common features of the interactions in both regions were interactions between a portion of the 50-kDa-domain and part of the converter domain of the myosin heads, similar to those found in the phosphorylation-regulated invertebrate myosin. These interactions are primarily electrostatic and the converter domain is responsible for the head-head interactions. Thus multiple head-head interactions of myosin crossbridges also characterize the switched-off state and have an important role in the regulation

  11. Accidental head injuries in children under 5 years of age

    International Nuclear Information System (INIS)

    Johnson, K.; Fischer, T.; Chapman, S.; Wilson, B.

    2005-01-01

    AIM: To evaluate the type and nature of head injuries sustained by children under the age of 5 years who present to a busy accident and emergency (A and E) department following an accidental fall. MATERIALS AND METHODS: This study included all children under the age of 5 years, who over an 8-month period were referred to our A and E Department with head injury following an accidental fall. Data were collected regarding the height of the fall, whether or not stairs were involved, the type of surface that the child landed on and the height of the child. This was correlated with any soft-tissue injury or skull fracture. RESULTS: A total of 72 children (aged 4 months to 4.75 years) fulfilled all the criteria for an accidental fall. The heights of the falls ranged from less than 50 cm to over 3 m, with the majority below 1 m. Of the falls, 49 were onto a hard surface and 23 were onto a soft surface. Of the 72 children, 52 had visible evidence of head injury, 35 (71%) of 49 being the result of falls onto hard surfaces and 17 (74%) of 23 onto soft (carpeted) surfaces. There was no significant difference in the type of surface that resulted in a visible head injury. A visible head injury was seen in all children who fell from a height of over 1.5 m and in 95% of children who fell over 1 m. Of the 72 children, 32 (44%) had skull radiographs performed in accordance with established guidelines and 4 (12.5%) were identified as having a fracture. Of the 3 linear parietal fractures 2 were inflicted by falls of just over 1 m (from a work surface) and 1 by a fall of 80 to 90 cm onto the hard-edged surface of a stone fire surround. The 4th was a fracture of the base of skull following a fall from more than 3 m (from a first-storey window). CONCLUSIONS: In the vast majority of domestic accidents children do not suffer significant harm. Skull fractures are rare and probably occur in less than 5% of cases. To cause a skull fracture the fall needs to be from over 1 m or, if from a

  12. Are patient specific meshes required for EIT head imaging?

    Science.gov (United States)

    Jehl, Markus; Aristovich, Kirill; Faulkner, Mayo; Holder, David

    2016-06-01

    Head imaging with electrical impedance tomography (EIT) is usually done with time-differential measurements, to reduce time-invariant modelling errors. Previous research suggested that more accurate head models improved image quality, but no thorough analysis has been done on the required accuracy. We propose a novel pipeline for creation of precise head meshes from magnetic resonance imaging and computed tomography scans, which was applied to four different heads. Voltages were simulated on all four heads for perturbations of different magnitude, haemorrhage and ischaemia, in five different positions and for three levels of instrumentation noise. Statistical analysis showed that reconstructions on the correct mesh were on average 25% better than on the other meshes. However, the stroke detection rates were not improved. We conclude that a generic head mesh is sufficient for monitoring patients for secondary strokes following head trauma.

  13. The development of remote controlled linear guide and mast vertical guide of repair robot for RV head CRDM nozzle region in NPP

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Seo, Yong Chil; Shin, Ho Cheol; Lee, Sung Uk; Jung, Kyung Min

    2006-11-01

    Reactor vessel which is core instrument in NPP must maintains integrity in the high temperature, high pressure and high radiation environment. Therefore RV must be inspected periodically. If there is defect, the RV must be repaired. A remote controlled linear guide and a vertical guide were developed for a welding repair robot of the RV head CRDM nozzle region. During inspection/maintenance, the RV head is placed RV head storage which is a double circled concrete structure. A linear guide was developed to provide a linear motion to the repair robot, which locates the robot under the RV head. The linear guide also provides a strong support to the robot not to overturn when the robot repairs the RV head. The robot needs lifting about 2m to reach the CRDM nozzle, therefore a vertical guide was developed. For easy traveling, the linear guide is designed 4 parts and the vertical guide is designed 3 parts. A control system was developed to remotely control the guide system which is composed of a connecter box, cables, control box, a computer and a control program. A monitoring system was developed to monitor operation of the guide system

  14. The development of remote controlled linear guide and mast vertical guide of repair robot for RV head CRDM nozzle region in NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Seo, Yong Chil; Shin, Ho Cheol; Lee, Sung Uk; Jung, Kyung Min

    2006-11-15

    Reactor vessel which is core instrument in NPP must maintains integrity in the high temperature, high pressure and high radiation environment. Therefore RV must be inspected periodically. If there is defect, the RV must be repaired. A remote controlled linear guide and a vertical guide were developed for a welding repair robot of the RV head CRDM nozzle region. During inspection/maintenance, the RV head is placed RV head storage which is a double circled concrete structure. A linear guide was developed to provide a linear motion to the repair robot, which locates the robot under the RV head. The linear guide also provides a strong support to the robot not to overturn when the robot repairs the RV head. The robot needs lifting about 2m to reach the CRDM nozzle, therefore a vertical guide was developed. For easy traveling, the linear guide is designed 4 parts and the vertical guide is designed 3 parts. A control system was developed to remotely control the guide system which is composed of a connecter box, cables, control box, a computer and a control program. A monitoring system was developed to monitor operation of the guide system.

  15. Protection against ionizing radiation by leaded glass googles during interventional cardiology

    International Nuclear Information System (INIS)

    Zett-Lobos, Claudio; Vera Munoz, Felipe; Arriola Alvarez, Katerina; Diaz Ramos, Oscar; Gamarra, Jorge; Fernandez Palomo, Cristian; Merello, Lorenzo; Mora D, Alex; Gutierrez, Alejandro; Catalan Reyes, Monica; Ramos Avasola, Sergio

    2013-01-01

    Background: It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP). Aim: To assess if the degree of attenuation of the secondary ionizing radiation achieved by the use of 0.25 mm Pb leaded glass goggles, in occupationally exposed workers in interventional cardiology procedures, meets the latest ICRP recommendations. Material and Methods : A prospective investigation was carried out to compare the eye exposure to secondary ionizing radiation received by occupationally exposed personnel in a 9 months period. A set of two thermo luminescent dosimeters was arranged in the front and back of leaded glass goggles in a cohort of seven members of an interventional cardiology service, exposed to 1057 consecutive procedures. Results:The monthly dose equivalent measurement performed in front of the goggles ranged between 1.1 and 6.5 mSv,for paramedics and interventional cardiologists. The radiation measured in the back of the glass varied between 0.66 and 2.75 mSv,respectively.The degree of attenuation of the dose at eye level ranged from 40% to 57.7%,respectively. The projected annual exposure would reach 33 mSv for the interventional cardiologist. Conclusions: With a similar load of work and wearing 0.25 mm Pb equivalent glass goggles, interventional cardiologists will exceed the crystalline equivalent dose limit recommended by the ICRP (20 mSv/year averaged over the past 5 years)

  16. Integrated Metabolo-Transcriptomics Reveals Fusarium Head Blight Candidate Resistance Genes in Wheat QTL-Fhb2.

    Directory of Open Access Journals (Sweden)

    Dhananjay Dhokane

    Full Text Available Fusarium head blight (FHB caused by Fusarium graminearum not only causes severe losses in yield, but also reduces quality of wheat grain by accumulating mycotoxins. Breeding for host plant resistance is considered as the best strategy to manage FHB. Resistance in wheat to FHB is quantitative in nature, involving cumulative effects of many genes governing resistance. The poor understanding of genetics and lack of precise phenotyping has hindered the development of FHB resistant cultivars. Though more than 100 QTLs imparting FHB resistance have been reported, none discovered the specific genes localized within the QTL region, nor the underlying mechanisms of resistance.In our study recombinant inbred lines (RILs carrying resistant (R-RIL and susceptible (S-RIL alleles of QTL-Fhb2 were subjected to metabolome and transcriptome profiling to discover the candidate genes. Metabolome profiling detected a higher abundance of metabolites belonging to phenylpropanoid, lignin, glycerophospholipid, flavonoid, fatty acid, and terpenoid biosynthetic pathways in R-RIL than in S-RIL. Transcriptome analysis revealed up-regulation of several receptor kinases, transcription factors, signaling, mycotoxin detoxification and resistance related genes. The dissection of QTL-Fhb2 using flanking marker sequences, integrating metabolomic and transcriptomic datasets, identified 4-Coumarate: CoA ligase (4CL, callose synthase (CS, basic Helix Loop Helix (bHLH041 transcription factor, glutathione S-transferase (GST, ABC transporter-4 (ABC4 and cinnamyl alcohol dehydrogenase (CAD as putative resistance genes localized within the QTL-Fhb2 region.Some of the identified genes within the QTL region are associated with structural resistance through cell wall reinforcement, reducing the spread of pathogen through rachis within a spike and few other genes that detoxify DON, the virulence factor, thus eventually reducing disease severity. In conclusion, we report that the wheat

  17. Remediation of attention deficits in head injury.

    OpenAIRE

    Nag S; Rao S

    1999-01-01

    Head injury is associated with psychological sequelae which impair the patient′s psychosocial functioning. Information processing, attention and memory deficits are seen in head injuries of all severity. We attempted to improve deficits of focused, sustained and divided attention. The principle of overlapping sources of attention resource pools was utilised in devising the remediation programme. Tasks used simple inexpensive materials. Four head injured young adult males with post conc...

  18. Head Impact Biomechanics in Women's College Soccer.

    Science.gov (United States)

    Lynall, Robert C; Clark, Michael D; Grand, Erin E; Stucker, Jaclyn C; Littleton, Ashley C; Aguilar, Alain J; Petschauer, Meredith A; Teel, Elizabeth F; Mihalik, Jason P

    2016-09-01

    There are limited nonlaboratory soccer head impact biomechanics data. This is surprising given soccer's global popularity. Epidemiological data suggest that female college soccer players are at a greater concussion injury risk than their male counterparts. Therefore, the purposes of our study were to quantify head impact frequency and magnitude during women's soccer practices and games in the National Collegiate Athletic Association and to characterize these data across event type, playing position, year on the team, and segment of game (first and second halves). Head impact biomechanics were collected from female college soccer players (n = 22; mean ± SD age = 19.1 ± 0.1 yr, height = 168.0 ± 3.5 cm, mass = 63.7 ± 6.0 kg). We employed a helmetless head impact measurement device (X2 Biosystems xPatch) before each competition and practice across a single season. Peak linear and rotational accelerations were categorized based on impact magnitude and subsequently analyzed using appropriate nonparametric analyses. Overall, women's college soccer players experience approximately seven impacts per 90 min of game play. The overwhelming majority (~90%) of all head impacts were categorized into our mildest linear acceleration impact classification (10g-20g). Interestingly, a higher percentage of practice impacts in the 20g-40g range compared with games (11% vs 7%) was observed. Head impact biomechanics studies have provided valuable insights into understanding collision sports and for informing evidence-based rule and policy changes. These have included changing the football kickoff, ice hockey body checking ages, and head-to-head hits in both sports. Given soccer's global popularity, and the growing public concern for the potential long-term neurological implications of collision and contact sports, studying soccer has the potential to impact many athletes and the sports medicine professionals caring for them.

  19. Live Speech Driven Head-and-Eye Motion Generators.

    Science.gov (United States)

    Le, Binh H; Ma, Xiaohan; Deng, Zhigang

    2012-11-01

    This paper describes a fully automated framework to generate realistic head motion, eye gaze, and eyelid motion simultaneously based on live (or recorded) speech input. Its central idea is to learn separate yet interrelated statistical models for each component (head motion, gaze, or eyelid motion) from a prerecorded facial motion data set: 1) Gaussian Mixture Models and gradient descent optimization algorithm are employed to generate head motion from speech features; 2) Nonlinear Dynamic Canonical Correlation Analysis model is used to synthesize eye gaze from head motion and speech features, and 3) nonnegative linear regression is used to model voluntary eye lid motion and log-normal distribution is used to describe involuntary eye blinks. Several user studies are conducted to evaluate the effectiveness of the proposed speech-driven head and eye motion generator using the well-established paired comparison methodology. Our evaluation results clearly show that this approach can significantly outperform the state-of-the-art head and eye motion generation algorithms. In addition, a novel mocap+video hybrid data acquisition technique is introduced to record high-fidelity head movement, eye gaze, and eyelid motion simultaneously.

  20. OCULAR MANIFESTATIONS OF HEAD INJURIES

    Directory of Open Access Journals (Sweden)

    Kanukollu Venkata Madusudana Rao

    2016-12-01

    Full Text Available BACKGROUND This prospective study aimed to evaluate the incidence of ocular manifestations in head injury and their correlation with the intracranial lesions. MATERIALS AND METHODS A total of 108 consecutive cases of closed head injury admitted in the neurosurgical ward of a tertiary teaching hospital underwent a thorough ophthalmic assessment. Clinical examination, radiological imaging and Glasgow Coma Scale (GCS were applied to grade the severity of injury. RESULTS Total number of 108 patients of head injury were examined of which 38 patients had ocular manifestations (35.18%. Of these, 85.18% were males, 84% of injuries were due to road traffic accidents and 16% were due to fall from a height. The ocular manifestations were as follows- Orbital complications were seen in 6 patients (15.8%. Anterior segment manifestations included black eyes seen in 10 patients (26.3%, subconjunctival haemorrhage in 10.5% of patients (4 patients, corneal involvement in 21% of patients (8 patients and pupillary involvement in 50% of patients (19 patients. Posterior segment manifestations were seen in 26.3% of patients (10 patients and were as follows- Purtscher’s retinopathy in 2 patients and optic atrophy in 5 patients. Cranial nerve palsies were seen in 15 patients (39.47% and supranuclear movement disorders were seen in 3 patients (8%. CONCLUSION Even though, neurosurgeons perform comprehensive clinical examination including eye examination, the main purpose is limited to aid topical diagnosis of neurological lesions. This study emphasises the importance of a detailed eye examination by an ophthalmologist to prevent irreversible visual loss in addition to aiding in the neurological diagnosis. Pupillary involvement, papilloedema and ocular motor paresis pointed to a more severe head injury. This observational prospective study helped us to correlate the severity of head injuries in association with ocular findings in patients admitted in neurosurgical ward

  1. Annotated Bibliography of the Army Research Institute’s Training Research Supporting the Land Warrior and Ground Soldier Systems: 1998-2009

    Science.gov (United States)

    2009-07-01

    AN/ PAQ -4C and AN-PEQ-2A) which were used in conjunction with night vision goggles (NVGs, AN/PVS-7B), the thermal weapon sight (TWS, AN/PAS-13), and...lights (AN/ PAQ -4C and AN-PEQ-2A) which were used in conjunction with night vision goggles (NVGs, AN/PVS-7B), and the thermal weapon sight (TWS, AN/PAS

  2. The Effect of Head Positioning and Head Tilting on the Incidence of Intraventricular Hemorrhage in Very Preterm Infants: A Systematic Review.

    Science.gov (United States)

    de Bijl-Marcus, Karen A; Brouwer, Annemieke J; de Vries, Linda S; van Wezel-Meijler, Gerda

    2017-01-01

    Despite advances in neonatal intensive care, germinal matrix-intraventricular hemorrhage (GMH-IVH) remains a frequent, serious complication of premature birth. Neutral head position and head tilting have been suggested to reduce the risk of GMH-IVH in preterm infants during the first 72 h of life. The aim of this study was to provide a systematic review of the effect of neutral head positioning and head tilting on the incidence of GMH-IVH in very preterm infants (gestational age ≤30 weeks). In addition, we reviewed their effect on cerebral hemodynamics and oxygenation. Literature was searched (June 2016) in the following electronic databases: CINAHL, Embase, Medline, SCOPUS, and several trial registers. One underpowered trial studied the effect of head positioning on the incidence of GMH-IVH. This randomized controlled trial enrolled 48 preterm infants and found no effect on the occurrence of GMH-IVH. Three observational studies investigated the effect of head rotation and/or tilting on cerebral oxygenation in 68 preterm infants in total. Their results suggest that cerebral oxygenation is not significantly affected by changes in head positioning. The effect of head positioning and/or tilting on cerebral hemodynamics was described in 2 observational studies of 28 preterm infants and found no significant effect. There is insufficient evidence regarding the effect of head positioning and tilting on the incidence of GMH-IVH and cerebral hemodynamics and oxygenation in preterm infants. We recommend further research in this field, especially in extremely preterm and clinically unstable infants during the first postnatal days. © 2016 S. Karger AG, Basel.

  3. Head Start Instructional Professionals' Inclusion Perceptions and Practices

    Science.gov (United States)

    Muccio, Leah S.; Kidd, Julie K.; White, C. Stephen; Burns, M. Susan

    2014-01-01

    This study considered the facilitators and barriers of successful inclusion in Head Start classrooms by examining the perspectives and practices of instructional professionals. A cross-sectional survey design was combined with direct observation in inclusive Head Start classrooms. Survey data were collected from 71 Head Start instructional…

  4. [Natural head position's reproducibility on photographs].

    Science.gov (United States)

    Eddo, Marie-Line; El Hayeck, Émilie; Hoyeck, Maha; Khoury, Élie; Ghoubril, Joseph

    2017-12-01

    The purpose of this study is to evaluate the reproducibility of natural head position with time on profile photographs. Our sample is composed of 96 students (20-30 years old) at the department of dentistry of Saint Joseph University in Beirut. Two profile photographs were taken in natural head position about a week apart. No significant differences were found between T0 and T1 (E = 1.065°). Many studies confirmed this reproducibility with time. Natural head position can be adopted as an orientation for profile photographs in orthodontics. © EDP Sciences, SFODF, 2017.

  5. BIOMECHANICS OF HEAD INJURY IN OLYMPIC TAEKWONDO AND BOXING

    Science.gov (United States)

    Fife, G.P.; Pieter, W.

    2013-01-01

    Objective The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. Methods For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Results Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Conclusions Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC. PMID:24744497

  6. Neuroimaging of nonaccidental head trauma: pitfalls and controversies

    Energy Technology Data Exchange (ETDEWEB)

    Fernando, Sujan [University of Missouri-Kansas School of Medicine, Department of Medicine, Kansas City, MO (United States); Obaldo, Ruby E. [The University of Kansas Medical Center, Department of Radiology, Kansas City, MO (United States); Walsh, Irene R. [The University of Missouri-Kansas City, Children' s Mercy Hospitals and Clinics, Department of Emergency Medicine, Kansas City, MO (United States); Lowe, Lisa H. [The University of Missouri-Kansas City, Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States)

    2008-08-15

    Although certain neuroimaging appearances are highly suggestive of abuse, radiological findings are often nonspecific. The objective of this review is to discuss pitfalls, controversies, and mimics occurring in neuroimaging of nonaccidental head trauma in order to allow the reader to establish an increased level of comfort in distinguishing between nonaccidental and accidental head trauma. Specific topics discussed include risk factors, general biomechanics and imaging strategies in nonaccidental head trauma, followed by the characteristics of skull fractures, normal prominent tentorium and falx versus subdural hematoma, birth trauma versus nonaccidental head trauma, hyperacute versus acute on chronic subdural hematomas, expanded subarachnoid space versus subdural hemorrhage, controversy regarding subdural hematomas associated with benign enlarged subarachnoid spaces, controversy regarding hypoxia as a cause of subdural hematoma and/or retinal hemorrhages without trauma, controversy regarding the significance of retinal hemorrhages related to nonaccidental head trauma, controversy regarding the significance of subdural hematomas in general, and pitfalls of glutaric aciduria type 1 and hemophagocytic lymphohistiocytosis mimicking nonaccidental head trauma. (orig.)

  7. Neuroimaging of nonaccidental head trauma: pitfalls and controversies

    International Nuclear Information System (INIS)

    Fernando, Sujan; Obaldo, Ruby E.; Walsh, Irene R.; Lowe, Lisa H.

    2008-01-01

    Although certain neuroimaging appearances are highly suggestive of abuse, radiological findings are often nonspecific. The objective of this review is to discuss pitfalls, controversies, and mimics occurring in neuroimaging of nonaccidental head trauma in order to allow the reader to establish an increased level of comfort in distinguishing between nonaccidental and accidental head trauma. Specific topics discussed include risk factors, general biomechanics and imaging strategies in nonaccidental head trauma, followed by the characteristics of skull fractures, normal prominent tentorium and falx versus subdural hematoma, birth trauma versus nonaccidental head trauma, hyperacute versus acute on chronic subdural hematomas, expanded subarachnoid space versus subdural hemorrhage, controversy regarding subdural hematomas associated with benign enlarged subarachnoid spaces, controversy regarding hypoxia as a cause of subdural hematoma and/or retinal hemorrhages without trauma, controversy regarding the significance of retinal hemorrhages related to nonaccidental head trauma, controversy regarding the significance of subdural hematomas in general, and pitfalls of glutaric aciduria type 1 and hemophagocytic lymphohistiocytosis mimicking nonaccidental head trauma. (orig.)

  8. Wheelchair control by head motion

    Directory of Open Access Journals (Sweden)

    Pajkanović Aleksandar

    2013-01-01

    Full Text Available Electric wheelchairs are designed to aid paraplegics. Unfortunately, these can not be used by persons with higher degree of impairment, such as quadriplegics, i.e. persons that, due to age or illness, can not move any of the body parts, except of the head. Medical devices designed to help them are very complicated, rare and expensive. In this paper a microcontroller system that enables standard electric wheelchair control by head motion is presented. The system comprises electronic and mechanic components. A novel head motion recognition technique based on accelerometer data processing is designed. The wheelchair joystick is controlled by the system’s mechanical actuator. The system can be used with several different types of standard electric wheelchairs. It is tested and verified through an experiment performed within this paper.

  9. Evaluation of head-free eye tracking as an input device for air traffic control.

    Science.gov (United States)

    Alonso, Roland; Causse, Mickaël; Vachon, François; Parise, Robert; Dehais, Frédéric; Terrier, Patrice

    2013-01-01

    The purpose of this study was to investigate the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC) activity. Sixteen participants used an eye tracker to select targets displayed on a screen as quickly and accurately as possible. We assessed the impact of the presence of visual feedback about gaze position and the method of target selection on selection performance under different difficulty levels induced by variations in target size and target-to-target separation. We tend to consider that the combined use of gaze dwell-time selection and continuous eye-gaze feedback was the best condition as it suits naturally with gaze displacement over the ATC display and free the hands of the controller, despite a small cost in terms of selection speed. In addition, target size had a greater impact on accuracy and selection time than target distance. These findings provide guidelines on possible further implementation of eye tracking in ATC everyday activity. We investigated the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC). We found that the combined use of gaze dwell-time selection and continuous eye-gaze feedback allowed the best performance and that target size had a greater impact on performance than target distance.

  10. Long-Term Follow-up of Modular Metallic Radial Head Replacement: Commentary on an article by Jonathan P. Marsh, MD, FRCSC, et al.: "Radial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years".

    OpenAIRE

    Mansat, Pierre

    2016-01-01

    Radial head arthroplasty is used to stabilize the joint after a complex acute radial head fracture that is not amenable for fixation or to treat sequelae of radial head fractures. Most of the currently used radial head prostheses are metallic monoblock implants that are not consistently adaptable and raise technical challenges since their implantation requires lateral elbow subluxation. Metallic modular radial head arthroplasty implants available in various head and stem sizes have been devel...

  11. Metamerism in cephalochordates and the problem of the vertebrate head.

    Science.gov (United States)

    Onai, Takayuki; Adachi, Noritaka; Kuratani, Shigeru

    2017-01-01

    The vertebrate head characteristically exhibits a complex pattern with sense organs, brain, paired eyes and jaw muscles, and the brain case is not found in other chordates. How the extant vertebrate head has evolved remains enigmatic. Historically, there have been two conflicting views on the origin of the vertebrate head, segmental and non-segmental views. According to the segmentalists, the vertebrate head is organized as a metameric structure composed of segments equivalent to those in the trunk; a metamere in the vertebrate head was assumed to consist of a somite, a branchial arch and a set of cranial nerves, considering that the head evolved from rostral segments of amphioxus-like ancestral vertebrates. Non-segmentalists, however, considered that the vertebrate head was not segmental. In that case, the ancestral state of the vertebrate head may be non-segmented, and rostral segments in amphioxus might have been secondarily gained, or extant vertebrates might have evolved through radical modifications of amphioxus-like ancestral vertebrate head. Comparative studies of mesodermal development in amphioxus and vertebrate gastrula embryos have revealed that mesodermal gene expressions become segregated into two domains anteroposteriorly to specify the head mesoderm and trunk mesoderm only in vertebrates; in this segregation, key genes such as delta and hairy, involved in segment formation, are expressed in the trunk mesoderm, but not in the head mesoderm, strongly suggesting that the head mesoderm of extant vertebrates is not segmented. Taken together, the above finding possibly adds a new insight into the origin of the vertebrate head; the vertebrate head mesoderm would have evolved through an anteroposterior polarization of the paraxial mesoderm if the ancestral vertebrate had been amphioxus-like.

  12. Multigenerational Head Start Participation: An Unexpected Marker of Progress

    Science.gov (United States)

    Chor, Elise

    2018-01-01

    One-quarter of the Head Start population has a mother who participated in the program as a child. This study uses experimental Head Start Impact Study (HSIS) data on 3- and 4-year-olds (N = 2,849) to describe multigenerational Head Start families and their program experiences. In sharp contrast to full-sample HSIS findings, Head Start has large,…

  13. Recognition and Evaluation of Clinical Section Headings in Clinical Documents Using Token-Based Formulation with Conditional Random Fields

    Directory of Open Access Journals (Sweden)

    Hong-Jie Dai

    2015-01-01

    Full Text Available Electronic health record (EHR is a digital data format that collects electronic health information about an individual patient or population. To enhance the meaningful use of EHRs, information extraction techniques have been developed to recognize clinical concepts mentioned in EHRs. Nevertheless, the clinical judgment of an EHR cannot be known solely based on the recognized concepts without considering its contextual information. In order to improve the readability and accessibility of EHRs, this work developed a section heading recognition system for clinical documents. In contrast to formulating the section heading recognition task as a sentence classification problem, this work proposed a token-based formulation with the conditional random field (CRF model. A standard section heading recognition corpus was compiled by annotators with clinical experience to evaluate the performance and compare it with sentence classification and dictionary-based approaches. The results of the experiments showed that the proposed method achieved a satisfactory F-score of 0.942, which outperformed the sentence-based approach and the best dictionary-based system by 0.087 and 0.096, respectively. One important advantage of our formulation over the sentence-based approach is that it presented an integrated solution without the need to develop additional heuristics rules for isolating the headings from the surrounding section contents.

  14. New strategy for the optimal design and manufacture of high performance milling heads

    Directory of Open Access Journals (Sweden)

    Bustillo, A.

    2011-12-01

    Full Text Available High-performance mechanical-transmission heads are one of the most complex, costly and problematic parts of a milling machine, owing to the large amount of piping required for transporting fluids and to the high level of mechanical performance that is required from them. This study proposes a strategy for optimising the design and manufacture of head bodies by using aluminium alloys and by integrating tubular stainless steel inserts in the casting of the head. These tubular inserts that are integrated into the aluminium mass are an alternative to cooling conduits currently made by machine drilling. As demonstrated in the experimental validation of the first prototype, the new method has created a design that retains the same mechanical performance, increases its reliability and reduces the weight of the milling machine’s moving parts.

    Los cabezales de transmisión mecánica de altas prestaciones son una de las partes más complejas, costosas y problemáticas de una maquina fresadora. Esto es debido a la gran cantidad de canalizaciones para la transmisión de fluidos que deben de contener y a las altas prestaciones mecánicas que se les exigen. En este trabajo se presenta una estrategia para optimizar el diseño y la fabricación de los cuerpos de estos cabezales basada en la incorporación de aleaciones de aluminio y la inclusión de insertos tubulares de acero en la propia fundición que conforma el cabezal. Los insertos tubulares sustituyen a los canales de refrigeración realizados actualmente por taladros de mecanizado y quedan integrados en la masa de aluminio. La nueva metodología ha permitido realizar un diseño que mantiene las prestaciones mecánicas, aumenta la fiabilidad y reduce la masa de estos elementos móviles de fresadoras como ha demostrado la validación experimental de un primer prototipo.

  15. The Head to Head That Had to Happen: A Case Study of Television Sport and Entrepreneurship.

    Science.gov (United States)

    Whannel, Garry

    The race between Mary Decker and Zola Budd, a head to head confrontation in the 1985 Olympic Games, is examined within the broader context of the transformation taking place in sports as a result of the combined efforts of television and the economic forces of sponsorship. Athletics is going through this process of transformation both economically…

  16. Interpersonal Coordination of Head Motion in Distressed Couples

    Science.gov (United States)

    Hammal, Zakia; Cohn, Jeffrey F.; George, David T.

    2015-01-01

    In automatic emotional expression analysis, head motion has been considered mostly a nuisance variable, something to control when extracting features for action unit or expression detection. As an initial step toward understanding the contribution of head motion to emotion communication, we investigated the interpersonal coordination of rigid head motion in intimate couples with a history of interpersonal violence. Episodes of conflict and non-conflict were elicited in dyadic interaction tasks and validated using linguistic criteria. Head motion parameters were analyzed using Student’s paired t-tests; actor-partner analyses to model mutual influence within couples; and windowed cross-correlation to reveal dynamics of change in direction of influence over time. Partners’ RMS angular displacement for yaw and RMS angular velocity for pitch and yaw each demonstrated strong mutual influence between partners. Partners’ RMS angular displacement for pitch was higher during conflict. In both conflict and non-conflict, head angular displacement and angular velocity for pitch and yaw were strongly correlated, with frequent shifts in lead-lag relationships. The overall amount of coordination between partners’ head movement was more highly correlated during non-conflict compared with conflict interaction. While conflict increased head motion, it served to attenuate interpersonal coordination. PMID:26167256

  17. Do Head Start Impacts Vary by Neighborhood Context?

    Science.gov (United States)

    Morris, Pamela A.; Connors, Maia C.; McCoy, Dana Charles; Gomez, Celia J.; Yoshikawa, Hiro; Aber, J. Lawrence

    2014-01-01

    This paper capitalizes on the addition of geocodes for Head Start centers in which children were randomly assigned to address questions about the role of neighborhood characteristics in moderating impacts of assignment to the Head Start program. Researchers explore the extent to which impacts of assignment to Head Start on outcomes for children…

  18. Maccoby's Head/Heart Traits: Marketing versus Accounting Students.

    Science.gov (United States)

    Kochunny, C. M.; And Others

    1992-01-01

    Nineteen head/heart traits derived from Maccoby's business ethics work were rated on importance to future careers by 148 marketing and 178 accounting students. Both groups rated head traits as most important. Marketing majors are not as "games" oriented as social stereotypes would indicate. The apparent imbalance between head and heart traits…

  19. Tridimensional pose estimation of a person head

    International Nuclear Information System (INIS)

    Perez Berenguer, Elisa; Soria, Carlos; Nasisi, Oscar; Mut, Vicente

    2007-01-01

    In this work, we present a method for estimating 3-D motion parameters; this method provides an alternative way for 3D head pose estimation from image sequence in the current computer vision literature. This method is robust over extended sequences and large head motions and accurately extracts the orientation angles of head from a single view. Experimental results show that this tracking system works well for development a human-computer interface for people that possess severe motor incapacity

  20. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  1. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  2. Antipredatory function of head shape for vipers and their mimics.

    Directory of Open Access Journals (Sweden)

    Janne K Valkonen

    Full Text Available Most research into the adaptive significance of warning signals has focused on the colouration and patterns of prey animals. However, behaviour, odour and body shape can also have signal functions and thereby reduce predators' willingness to attack defended prey. European vipers all have a distinctive triangular head shape; and they are all venomous. Several non-venomous snakes, including the subfamily Natricinae, commonly flatten their heads (also known as head triangulation when disturbed. The adaptive significance of this potential behavioural mimicry has never been investigated.We experimentally tested if the triangular head shape typical of vipers offers protection against predation. We compared the predation pressure of free-ranging predators on artificial snakes with triangular-shaped heads against the pressure on replicas with narrow heads. Snakes of both head types had either zigzag patterned bodies, typical of European vipers, or plain (patternless bodies. Plain snakes with narrower Colubrid-like heads suffered significantly higher predation by raptors than snakes with triangular-shaped heads. Head shape did not, however, have an additive effect on survival in zigzag-patterned snakes, suggesting that species which differ from vipers in colouration and pattern would benefit most from behavioural mimicry. Our results demonstrate that the triangular head shape typical of vipers can act as a warning signal to predators. We suggest that head-shape mimicry may be a more common phenomenon among more diverse taxa than is currently recognised.

  3. The Impact of Head Start on Children, Families and Communities. Final Report of the Head Start Evaluation, Synthesis and Utilization Project.

    Science.gov (United States)

    McKey, Ruth Hubbell; And Others

    Including all Head Start research (both published and unpublished) and using, when possible, the statistical technique of meta-analysis, this final report of the Head Start Evaluation, Synthesis, and Utilization Project presents findings on the impact of Head Start on children's cognitive and socioemotional development, on child health and health…

  4. Nintendo Wii remote controllers for head posture measurement: accuracy, validity, and reliability of the infrared optical head tracker.

    Science.gov (United States)

    Kim, Jongshin; Nam, Kyoung Won; Jang, Ik Gyu; Yang, Hee Kyung; Kim, Kwang Gi; Hwang, Jeong-Min

    2012-03-15

    To evaluate the accuracy, validity, and reliability of a newly developed infrared optical head tracker (IOHT) using Nintendo Wii remote controllers (WiiMote; Nintendo Co. Ltd., Kyoto, Japan) for measurement of the angle of head posture. The IOHT consists of two infrared (IR) receivers (WiiMote) that are fixed to a mechanical frame and connected to a monitoring computer via a Bluetooth communication channel and an IR beacon that consists of four IR light-emitting diodes (LEDs). With the use of the Cervical Range of Motion (CROM; Performance Attainment Associates, St. Paul, MN) as a reference, one- and three-dimensional (1- and 3-D) head postures of 20 normal adult subjects (20-37 years of age; 9 women and 11 men) were recorded with the IOHT. In comparison with the data from the CROM, the IOHT-derived results showed high consistency. The measurements of 1- and 3-D positions of the human head with the IOHT were very close to those of the CROM. The correlation coefficients of 1- and 3-D positions between the IOHT and the CROM were more than 0.99 and 0.96 (P < 0.05, Pearson's correlation test), respectively. Reliability tests of the IOHT for the normal adult subjects for 1- and 3-D positions of the human head had 95% limits of agreement angles of approximately ±4.5° and ±8.0°, respectively. The IOHT showed strong concordance with the CROM and relatively good test-retest reliability, thus proving its validity and reliability as a head-posture-measuring device. Considering its high performance, ease of use, and low cost, the IOHT has the potential to be widely used as a head-posture-measuring device in clinical practice.

  5. Design verification for reactor head replacement

    International Nuclear Information System (INIS)

    Dwivedy, K.K.; Whitt, M.S.; Lee, R.

    2005-01-01

    This paper outlines the challenges of design verification for reactor head replacement for PWR plants and the program for qualification from the prospective of the utility design engineering group. This paper is based on the experience with the design confirmation of four reactor head replacements for two plants, and their interfacing components, parts, appurtenances, and support structures. The reactor head replacement falls under the jurisdiction of the applicable edition of the ASME Section XI code, with particular reference to repair/replacement activities. Under any repair/replacement activities, demands may be encountered in the development of program and plan for replacement due to the vintage of the original design/construction Code and the design reports governing the component qualifications. Because of the obvious importance of the reactor vessel, these challenges take on an added significance. Additional complexities are introduced to the project, when the replacement components are fabricated by vendors different from the original vendor. Specific attention is needed with respect to compatibility with the original design and construction of the part and interfacing components. The program for reactor head replacement requires evaluation of welding procedures, applicable examination, test, and acceptance criteria for material, welds, and the components. Also, the design needs to take into consideration the life of the replacement components with respect to the extended period of operation of the plant after license renewal and other plant improvements. Thus, the verification of acceptability of reactor head replacement provides challenges for development and maintenance of a program and plan, design specification, design report, manufacturer's data report and material certification, and a report of reconciliation. The technical need may also be compounded by other challenges such as widely scattered global activities and organizational barriers, which

  6. Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom

    International Nuclear Information System (INIS)

    Evans, Jeffrey F.; Blue, Thomas E.; Gupta, Nilendu

    2001-01-01

    The purpose of this article is to demonstrate the viability of using a high-resolution 3-D head phantom in Monte Carlo N-Particle (MCNP) for boron neutron capture therapy (BNCT) structure dosimetry. This work describes a high-resolution voxel-based model of a human head and its use for calculating absorbed doses to the structures of the brain. The Zubal head phantom is a 3-D model of a human head that can be displayed and manipulated on a computer. Several changes were made to the original head phantom which now contains over 29 critical structures of the brain and head. The modified phantom is a 85x109x120 lattice of voxels, where each voxel is 2.2x2.2x1.4 mm 3 . This model was translated into MCNP lattice format. As a proof of principle study, two MCNP absorbed dose calculations were made (left and right lateral irradiations) using a uniformly distributed neutron disk source with an 1/E energy spectrum. Additionally, the results of these two calculations were combined to estimate the absorbed doses from a bilateral irradiation. Radiobiologically equivalent (RBE) doses were calculated for all structures and were normalized to 12.8 Gy-Eq. For a left lateral irradiation, the left motor cortex receives the limiting RBE dose. For a bilateral irradiation, the insula cortices receive the limiting dose. Among the nonencephalic structures, the parotid glands receive RBE doses that were within 15% of the limiting dose

  7. Head capsule, chephalic central nervous system and head circulatory system of an aberrant orthopteran, Prosarthria teretrirostris (Caelifera, Hexapoda).

    Science.gov (United States)

    Baum, Eileen; Hertel, Wieland; Beutel, Rolf Georg

    2007-01-01

    The head capsule, the circulatory system and the central nervous system of the head of Prosarthria teretrirostris (Proscopiidae) is described in detail, with special consideration of modifications resulting from the aberrant head shape. The transformations of the head are completely different from those found in phasmatodeans, which are also characterised by twig mimesis. The circulatory system is distinctly modified. A hitherto undescribed additional structure in the posterior head region very likely functions as a pulsatile organ. The cephalic central nervous system is strongly elongated, with changes in the position of the suboesophageal ganglion, the corpora cardiaca and the course of the nervus mandibularis. Three-dimensional reconstructions of these two organ systems in combination with the pharynx were made using Alias Maya 6.0 software. Comparisons with other representatives of Caelifera suggest a clade comprising Proscopiidae and Morabinae. The presence of a transverse muscle connecting the antennal ampullae in Prosarthria shows that this structure likely belongs to the groundplan of Orthoptera, even though it is missing in different representatives of this group. The transverse ampullary muscle is a potential synapomorphy of Orthoptera, Phasmatodea and Dictyoptera.

  8. [Abnormal head turn in a patient with Brown's syndrome].

    Science.gov (United States)

    van Waveren, M; Krzizok, T; Besch, D

    2008-08-01

    We report on an eight-year-old boy, who was presented in our clinic because of head turn. The cause of the tortecollis (ocular or general) in this case was and still cannot be explained. Only by applying extensive prism adaptation tests it was possible to prove the ocular character of the head turn. An eight-year-old boy with Brown's syndrome was referred to us because of a head tilt to the left side. Six months previously surgery on the M. obl. superior of the right eye was performed in another clinic. No improvement of the head tilt could be observed after the operation. In addition, an exotropia became decompensated. Under a 3-day occlusion of one eye, no change of the head turn and the squint could be measured. No other cause of the head turn could be found by an orthopaedist and a paediatrist. Under a prism of 20 cm/m basis in and 10 cm/m basis against the positive vertical deviation, the head tilt decreased, so that we decided to do a second surgery. The head tilting had not resumed at one year after the surgery. Although the initial diagnostic findings ruled out an ocular cause, it was possible to lessen the head tilting with the aid of the prism adaptation test. This case study emphasises the usefulness of a prism adaptation test of several days duration in order to validate an ocular cause of head turn and to determine an adequate indication for surgery.

  9. PRACTICAL MANAGEMENT OF HEAD INJURY | Shehu | Annals of ...

    African Journals Online (AJOL)

    For an effective practical management of head injury, a clear knowledge of the various causes and mechanism of head injury is essential. The concept of the brain in a rigid cranial cavity makes the pathophysiological mechanism of head trauma unique. Most problems occur due to poor handling of patients at the site of ...

  10. Modelling of waves propagation on irregular surfaces using ray tracing and GTD approaches: Application to head waves simulation in TOFD inspections for NDT

    Science.gov (United States)

    Ferrand, Adrien; Darmon, Michel; Chatillon, Sylvain; Deschamps, Marc

    2014-04-01

    The Time of Flight Diffraction (TOFD) technique is a classical ultrasonic method used in ultrasonic non-destructive evaluation, which allows a precise positioning and a quantitative size evaluation of cracks in the inspected material. Among the typical phenomena arising in the current TOFD inspection, the so-called "head wave" is the first contribution reaching the receiver. The head wave propagation on a planar interface is well known and identified as a critical refraction taking place on the material surface. On irregular surfaces, it has been shown that the head wave results from the melting of surface and bulk waves mechanisms and that surface irregularities are responsible for numerous diffractions of the incident head wave. To simulate such behaviour, a model has been developed using a ray tracing technique based on time of flight minimization (generalized Fermat's principle). It enables the calculation of the ray path and the corresponding time of flight of all waves propagating in the material, including the head wave. To obtain a complete propagation model for these waves (both trajectory and amplitude), the integration of Geometrical Theory of Diffraction (GTD) models is currently performed by coupling them with the ray-based approach discussed above.

  11. Avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1990-01-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author)

  12. Allocation of Attention with Head-Up Displays

    National Research Council Canada - National Science Library

    Wickens, C

    1998-01-01

    Two experiments examined the effects of display location (head up vs. head down) and image intensity/clutter on flight path performance and mid-air target detection in a general aviation cruise flight environment...

  13. Pocket Proteins Suppress Head and Neck Cancer

    Science.gov (United States)

    Shin, Myeong-Kyun; Pitot, Henry C.; Lambert, Paul F.

    2012-01-01

    Head and neck squamous cell carcinomas (HNSCC) is a common cancer in humans long known to be caused by tobacco and alcohol use, but now an increasing percentage of HNSCC is recognized to be caused by the same human papillomaviruses (HPVs) that cause cervical and other anogenital cancers. HPV-positive HNSCCs differ remarkably from HPV-negative HNSCCs in their clinical response and molecular properties. From studies in mice, we know that E7 is the dominant HPV oncoprotein in head and neck cancer. E7 is best known for its ability to inactivate pRb, the product of the retinoblastoma tumor susceptibility gene. However loss of pRb function does not fully account for E7’s potency in causing head and neck cancer. In this study, we characterized the cancer susceptibility of mice deficient in the expression of pRb and either of two related “pocket” proteins, p107 and p130, that are also inactivated by E7. pRb/p107 deficient mice developed head and neck cancer as frequently as do HPV16 E7 transgenic mice. The head and neck epithelia of the pRb/p107 deficient mice also displayed the same acute phenotypes and biomarker readouts as observed in the epithelia of E7 transgenic mice. Mice deficient for pRb and p130 in their head and neck epithelia showed intermediate acute and tumor phenotypes. We conclude that pRb and p107 act together to efficiently suppress head and neck cancer, and are therefore highly relevant targets of HPV16 E7 in its contribution to HPV-positive HNSCC. PMID:22237625

  14. Facial preservation following extreme mummification: Shrunken heads.

    Science.gov (United States)

    Houlton, Tobias M R; Wilkinson, Caroline

    2018-05-01

    Shrunken heads are a mummification phenomenon unique to South America. Ceremonial tsantsa are ritually reduced heads from enemy victims of the Shuar, Achuar, Awajún (Aguaruna), Wampís (Huambisa), and Candoshi-Shapra cultures. Commercial shrunken heads are comparatively modern and fraudulently produced for the curio-market, often using stolen bodies from hospital mortuaries and graves. To achieve shrinkage and desiccation, heads undergo skinning, simmering (in water) and drying. Considering the intensive treatments applied, this research aims to identify how the facial structure can alter and impact identification using post-mortem depiction. Sixty-five human shrunken heads were assessed: 6 ceremonial, 36 commercial, and 23 ambiguous. Investigations included manual inspection, multi-detector computerised tomography, infrared reflectography, ultraviolet fluorescence and microscopic hair analysis. The mummification process disfigures the outer face, cheeks, nasal root and bridge form, including brow ridge, eyes, ears, mouth, and nose projection. Melanin depletion, epidermal degeneration, and any applied staining changes the natural skin complexion. Papillary and reticular dermis separation is possible. Normal hair structure (cuticle, cortex, medulla) is retained. Hair appears longer (unless cut) and more profuse following shrinkage. Significant features retained include skin defects, facial creases, hairlines and earlobe form. Hair conditions that only affect living scalps are preserved (e.g. nits, hair casts). Ear and nose cartilage helps to retain some morphological information. Commercial heads appear less distorted than ceremonial tsantsa, often presenting a definable eyebrow shape, vermillion lip shape, lip thickness (if mouth is open), philtrum form, and palpebral slit angle. Facial identification capabilities are considered limited, and only perceived possible for commercial heads. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. 21 CFR 868.5560 - Gas mask head strap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  16. Dairy production in some selected integrated farms in Sokoto State ...

    African Journals Online (AJOL)

    A survey of eight integrated farms in four local government areas of Sokoto state in north-western Nigeria revealed the following about dairy production on such farms:breed of cattle kept, Sokoto Gudali, Friesian, and Sahiwal; average dairy herd size,69.4 head; husbandry system was largely semi-intensive; milking was ...

  17. 76 FR 70009 - Head Start Program

    Science.gov (United States)

    2011-11-09

    ... importance of the early years of a child's growth and development. On December 12, 2007, the Improving Head... education, serving nearly one million of our nation's most vulnerable young children and their families. It... Administration for Children and Families 45 CFR Part 1307 Head Start Program; Final Rule #0;#0;Federal Register...

  18. Validating a Method to Assess Lipreading, Audiovisual Gain, and Integration During Speech Reception With Cochlear-Implanted and Normal-Hearing Subjects Using a Talking Head.

    Science.gov (United States)

    Schreitmüller, Stefan; Frenken, Miriam; Bentz, Lüder; Ortmann, Magdalene; Walger, Martin; Meister, Hartmut

    Watching a talker's mouth is beneficial for speech reception (SR) in many communication settings, especially in noise and when hearing is impaired. Measures for audiovisual (AV) SR can be valuable in the framework of diagnosing or treating hearing disorders. This study addresses the lack of standardized methods in many languages for assessing lipreading, AV gain, and integration. A new method is validated that supplements a German speech audiometric test with visualizations of the synthetic articulation of an avatar that was used, for it is feasible to lip-sync auditory speech in a highly standardized way. Three hypotheses were formed according to the literature on AV SR that used live or filmed talkers. It was tested whether respective effects could be reproduced with synthetic articulation: (1) cochlear implant (CI) users have a higher visual-only SR than normal-hearing (NH) individuals, and younger individuals obtain higher lipreading scores than older persons. (2) Both CI and NH gain from presenting AV over unimodal (auditory or visual) sentences in noise. (3) Both CI and NH listeners efficiently integrate complementary auditory and visual speech features. In a controlled, cross-sectional study with 14 experienced CI users (mean age 47.4) and 14 NH individuals (mean age 46.3, similar broad age distribution), lipreading, AV gain, and integration of a German matrix sentence test were assessed. Visual speech stimuli were synthesized by the articulation of the Talking Head system "MASSY" (Modular Audiovisual Speech Synthesizer), which displayed standardized articulation with respect to the visibility of German phones. In line with the hypotheses and previous literature, CI users had a higher mean visual-only SR than NH individuals (CI, 38%; NH, 12%; p < 0.001). Age was correlated with lipreading such that within each group, younger individuals obtained higher visual-only scores than older persons (rCI = -0.54; p = 0.046; rNH = -0.78; p < 0.001). Both CI and NH

  19. Head Start at ages 3 and 4 versus Head Start followed by state pre-k: Which is more effective?

    Science.gov (United States)

    Jenkins, Jade Marcus; Farkas, George; Duncan, Greg J.; Burchinal, Margaret; Vandell, Deborah Lowe

    2016-01-01

    As policy-makers contemplate expanding preschool opportunities for low-income children, one possibility is to fund two, rather than one year of Head Start for children at ages 3 and 4. Another option is to offer one year of Head Start followed by one year of pre-k. We ask which of these options is more effective. We use data from the Oklahoma pre-k study to examine these two ‘pathways’ into kindergarten using regression discontinuity to estimate the effects of each age-4 program, and propensity score weighting to address selection. We find that children attending Head Start at age 3 develop stronger pre-reading skills in a high quality pre-kindergarten at age 4 compared with attending Head Start at age 4. Pre-k and Head Start were not differentially linked to improvements in children’s pre-writing skills or pre-math skills. This suggests that some impacts of early learning programs may be related to the sequencing of learning experiences to more academic programming. PMID:27076692

  20. Supporting Optimal Child Development through Early Head Start and Head Start Programs: Reflections on Secondary Data Analyses of FACES and EHSREP

    Science.gov (United States)

    Chazan-Cohen, Rachel; Halle, Tamara G.; Barton, Lauren R.; Winsler, Adam

    2012-01-01

    We are delighted to reflect on the 10 papers highlighted in this important special issue of "Early Childhood Research Quarterly" devoted to recent secondary data analyses of the FACES and EHSREP datasets. First, we provide some background on Head Start research and give an overview of the large-scale Head Start and Early Head Start…

  1. HPV Integration in HNSCC Correlates with Survival Outcomes, Immune Response Signatures, and Candidate Drivers.

    Science.gov (United States)

    Koneva, Lada A; Zhang, Yanxiao; Virani, Shama; Hall, Pelle B; McHugh, Jonathan B; Chepeha, Douglas B; Wolf, Gregory T; Carey, Thomas E; Rozek, Laura S; Sartor, Maureen A

    2018-01-01

    The incidence of human papillomavirus (HPV)-related oropharynx cancer has steadily increased over the past two decades and now represents a majority of oropharyngeal cancer cases. Integration of the HPV genome into the host genome is a common event during carcinogenesis that has clinically relevant effects if the viral early genes are transcribed. Understanding the impact of HPV integration on clinical outcomes of head and neck squamous cell carcinoma (HNSCC) is critical for implementing deescalated treatment approaches for HPV + HNSCC patients. RNA sequencing (RNA-seq) data from HNSCC tumors ( n = 84) were used to identify and characterize expressed integration events, which were overrepresented near known head and neck, lung, and urogenital cancer genes. Five genes were recurrent, including CD274 (PD-L1) A significant number of genes detected to have integration events were found to interact with Tp63, ETS, and/or FOX1A. Patients with no detected integration had better survival than integration-positive and HPV - patients. Furthermore, integration-negative tumors were characterized by strongly heightened signatures for immune cells, including CD4 + , CD3 + , regulatory, CD8 + T cells, NK cells, and B cells, compared with integration-positive tumors. Finally, genes with elevated expression in integration-negative specimens were strongly enriched with immune-related gene ontology terms, while upregulated genes in integration-positive tumors were enriched for keratinization, RNA metabolism, and translation. Implications: These findings demonstrate the clinical relevancy of expressed HPV integration, which is characterized by a change in immune response and/or aberrant expression of the integration-harboring cancer-related genes, and suggest strong natural selection for tumor cells with expressed integration events in key carcinogenic genes. Mol Cancer Res; 16(1); 90-102. ©2017 AACR . ©2017 American Association for Cancer Research.

  2. Magnetic resonance imaging of the femoral head necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro and others

    1986-06-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T/sub 1/ relaxation time was 160 +- 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T/sub 1/ relaxation time, while the reactive fibrous area had more prolonged T/sub 1/ relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning.

  3. Magnetic resonance imaging of the femoral head necrosis

    International Nuclear Information System (INIS)

    Narita, Shinya; Asada, Kanji; Yoshida, Kenjiro

    1986-01-01

    Ten patients with avascular femoral head necrosis and four normal adults were examined by magnetic resonance imaging (MRI). In addition, the relationship between MRI and pathophysiology of three operated-on avascular femoral heads was evaluated. The medullary cavities of the normal femoral heads had a strong signal intensity on the saturation recovery (SR) image due to fat marrow, and the T 1 relaxation time was 160 ± 11 msec. In avascular femoral head necrosis, the necrotic area had a low signal intensity on the SR image and a prolonged T 1 relaxation time, while the reactive fibrous area had more prolonged T 1 relaxation time. For these reasons, MRI was found to show the pathological changes of avascular femoral head necrosis and can be expected to be useful for making early diagnoses and operation planning. (author)

  4. Eliminating drift of the head gesture reference to enhance Google Glass-based control of an NAO humanoid robot

    Directory of Open Access Journals (Sweden)

    Xiaoqian Mao

    2017-03-01

    Full Text Available This article presents a strategy for hand-free control of an NAO humanoid robot via head gesture detected by Google Glass-based multi-sensor fusion. First, we introduce a Google Glass-based robot system by integrating the Google Glass and the NAO humanoid robot, which is able to send robot commands through Wi-Fi communications between the Google Glass and the robot. Second, we detect the operator’s head gestures by processing data from multiple sensors including accelerometers, geomagnetic sensors and gyroscopes. Next, we use a complementary filter to eliminate drift of the head gesture reference, which greatly improves the control performance. This is accomplished by the high-pass filter component on the control signal. Finally, we conduct obstacle avoidance experiments while navigating the robot to validate the effectiveness and reliability of this system. The experimental results show that the robot is smoothly navigated from its initial position to its destination with obstacle avoidance via the Google Glass. This hands-free control system can benefit those with paralysed limbs.

  5. Head stabilization in whooping cranes

    Science.gov (United States)

    Kinloch, M.R.; Cronin, T.W.; Olsen, Glenn H.; Chavez-Ramirez, Felipe

    2005-01-01

    The whooping crane (Grus americana) is the tallest bird in North America, yet not much is known about its visual ecology. How these birds overcome their unusual height to identify, locate, track, and capture prey items is not well understood. There have been many studies on head and eye stabilization in large wading birds (herons and egrets), but the pattern of head movement and stabilization during foraging is unclear. Patterns of head movement and stabilization during walking were examined in whooping cranes at Patuxent Wildlife Research Center, Laurel, Maryland USA. Four whooping cranes (1 male and 3 females) were videotaped for this study. All birds were already acclimated to the presence of people and to food rewards. Whooping cranes were videotaped using both digital and Hi-8 Sony video cameras (Sony Corporation, 7-35 Kitashinagawa, 6-Chome, Shinagawa-ku, Tokyo, Japan), placed on a tripod and set at bird height in the cranes' home pens. The cranes were videotaped repeatedly, at different locations in the pens and while walking (or running) at different speeds. Rewards (meal worms, smelt, crickets and corn) were used to entice the cranes to walk across the camera's view plane. The resulting videotape was analyzed at the University of Maryland at Baltimore County. Briefly, we used a computerized reduced graphic model of a crane superimposed over each frame of analyzed tape segments by means of a custom written program (T. W. Cronin, using C++) with the ability to combine video and computer graphic input. The speed of the birds in analyzed segments ranged from 0.30 m/s to 2.64 m/s, and the proportion of time the head was stabilized ranged from 79% to 0%, respectively. The speed at which the proportion reached 0% was 1.83 m/s. The analyses suggest that the proportion of time the head is stable decreases as speed of the bird increases. In all cases, birds were able to reach their target prey with little difficulty. Thus when cranes are walking searching for food

  6. Head Start Impact Study. Technical Report

    Science.gov (United States)

    Puma, Michael; Bell, Stephen; Cook, Ronna; Heid, Camilla; Shapiro, Gary; Broene, Pam; Jenkins, Frank; Fletcher, Philip; Quinn, Liz; Friedman, Janet; Ciarico, Janet; Rohacek, Monica; Adams, Gina; Spier, Elizabeth

    2010-01-01

    This Technical Report is designed to provide technical detail to support the analysis and findings presented in the "Head Start Impact Study Final Report" (U.S. Department of Health and Human Services, January 2010). Chapter 1 provides an overview of the Head Start Impact Study and its findings. Chapter 2 provides technical information on the…

  7. Electromagnetic interference-induced instability in CPP-GMR read heads

    International Nuclear Information System (INIS)

    Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A.; Mewes, T.; Mewes, C.K.A.; Kruesubthaworn, A.

    2016-01-01

    Electromagnetic interference (EMI) has been a significant issue for the current perpendicular-to-the-plane giant magnetoresistance (CPP-GMR) read heads because it can cause magnetic failure. Furthermore, the magnetic noise induced by the spin transfer torque (STT) effect has played an important role in the CPP read heads because it can affect the stability of the heads. Accordingly, this work proposed an investigation of the magnetic instabilities induced by EMI through the STT effect in a CPP-GMR read head via micromagnetic simulations. The magnetization fluctuation caused by EMI was examined, and then, magnetic noise was evaluated by using power spectral density analysis. It was found that the magnetization orientation can be fluctuated by EMI in close proximity to the head. The results also showed a multimode spectral density. The main contributions of the spectral density were found to originate at the edges of the stripe height sides due to the characteristics of the demagnetization field inside the free layer. Hence, the magnetic instabilities produced by EMI become a significant factor that essentially impacts the reliability of the CPP-GMR read heads. - Highlights: • The instability induced by electromagnetic interference in read head is examined. • The magnetization orientation can be fluctuated by electromagnetic interference. • The electromagnetic interference can induce additional noise spectra to the system. • The noise is mainly located at stripe height of the read head. • The noise induced by electromagnetic interference is a crucial factor for the head.

  8. Electromagnetic interference-induced instability in CPP-GMR read heads

    Energy Technology Data Exchange (ETDEWEB)

    Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A. [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Mewes, T.; Mewes, C.K.A. [Department of Physics and Astronomy, MINT Center, University of Alabama, Tuscaloosa, AL 35487 (United States); Kruesubthaworn, A., E-mail: anankr@kku.ac.th [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand)

    2016-08-15

    Electromagnetic interference (EMI) has been a significant issue for the current perpendicular-to-the-plane giant magnetoresistance (CPP-GMR) read heads because it can cause magnetic failure. Furthermore, the magnetic noise induced by the spin transfer torque (STT) effect has played an important role in the CPP read heads because it can affect the stability of the heads. Accordingly, this work proposed an investigation of the magnetic instabilities induced by EMI through the STT effect in a CPP-GMR read head via micromagnetic simulations. The magnetization fluctuation caused by EMI was examined, and then, magnetic noise was evaluated by using power spectral density analysis. It was found that the magnetization orientation can be fluctuated by EMI in close proximity to the head. The results also showed a multimode spectral density. The main contributions of the spectral density were found to originate at the edges of the stripe height sides due to the characteristics of the demagnetization field inside the free layer. Hence, the magnetic instabilities produced by EMI become a significant factor that essentially impacts the reliability of the CPP-GMR read heads. - Highlights: • The instability induced by electromagnetic interference in read head is examined. • The magnetization orientation can be fluctuated by electromagnetic interference. • The electromagnetic interference can induce additional noise spectra to the system. • The noise is mainly located at stripe height of the read head. • The noise induced by electromagnetic interference is a crucial factor for the head.

  9. Sexual dimorphism of head morphology in three-spined stickleback Gasterosteus aculeatus.

    Science.gov (United States)

    Aguirre, W E; Akinpelu, O

    2010-09-01

    This study examined sexual dimorphism of head morphology in the ecologically diverse three-spined stickleback Gasterosteus aculeatus. Male G. aculeatus had longer heads than female G. aculeatus in all 10 anadromous, stream and lake populations examined, and head length growth rates were significantly higher in males in half of the populations sampled, indicating that differences in head size increased with body size in many populations. Despite consistently larger heads in males, there was significant variation in size-adjusted head length among populations, suggesting that the relationship between head length and body length was flexible. Inter-population differences in head length were correlated between sexes, thus population-level factors influenced head length in both sexes despite the sexual dimorphism present. Head shape variation between lake and anadromous populations was greater than that between sexes. The common divergence in head shape between sexes across populations was about twice as important as the sexual dimorphism unique to each population. Finally, much of the sexual dimorphism in head length was due to divergence in the anterior region of the head, where the primary trophic structures were found. It is unclear whether the sexual dimorphism was due to natural selection for niche divergence between sexes or sexual selection. This study improves knowledge of the magnitude, growth rate divergence, inter-population variation and location of sexual dimorphism in G. aculeatus head morphology. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  10. Analysis of linear head accelerations from collegiate football impacts.

    Science.gov (United States)

    Brolinson, P Gunnar; Manoogian, Sarah; McNeely, David; Goforth, Mike; Greenwald, Richard; Duma, Stefan

    2006-02-01

    Sports-related concussions result in 300,000 brain injuries in the United States each year. We conducted a study utilizing an in-helmet system that measures and records linear head accelerations to analyze head impacts in collegiate football. The Head Impact Telemetry (HIT) System is an in-helmet system with six spring-mounted accelerometers and an antenna that transmits data via radio frequency to a sideline receiver and laptop computer system. A total of 11,604 head impacts were recorded from the Virginia Tech football team throughout the 2003 and 2004 football seasons during 22 games and 62 practices from a total of 52 players. Although the incidence of injury data are limited, this study presents an extremely large data set from human head impacts that provides valuable insight into the lower limits of head acceleration that cause mild traumatic brain injuries.

  11. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  12. Artificial neural networks: Predicting head CT findings in elderly patients presenting with minor head injury after a fall.

    Science.gov (United States)

    Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L

    2017-02-01

    To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline.

  14. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline

  15. Pattern of head and neck cancers among patients attending ...

    African Journals Online (AJOL)

    Lack of baseline data in Tanzania concerning head and ... that there is a synergistic effect of alcohol consumption and tobacco use in causing head and neck cancers ... risk factors, while radiation around the head and neck is associated with ...

  16. Biomechanics of Heading a Soccer Ball: Implications for Player Safety

    Directory of Open Access Journals (Sweden)

    Charles F. Babbs

    2001-01-01

    Full Text Available To better understand the risk and safety of heading a soccer ball, the author created a set of simple mathematical models based upon Newton�s second law of motion to describe the physics of heading. These models describe the player, the ball, the flight of the ball before impact, the motion of the head and ball during impact, and the effects of all of these upon the intensity and the duration of acceleration of the head. The calculated head accelerations were compared to those during presumably safe daily activities of jumping, dancing, and head nodding and also were related to established criteria for serious head injury from the motor vehicle crash literature. The results suggest heading is usually safe but occasionally dangerous, depending on key characteristics of both the player and the ball. Safety is greatly improved when players head the ball with greater effective body mass, which is determined by a player�s size, strength, and technique. Smaller youth players, because of their lesser body mass, are more at risk of potentially dangerous headers than are adults, even when using current youth size balls. Lower ball inflation pressure reduces risk of dangerous head accelerations. Lower pressure balls also have greater “touch” and “playability”, measured in terms of contact time and contact area between foot and ball during a kick. Focus on teaching proper technique, the re-design of age-appropriate balls for young players with reduced weight and inflation pressure, and avoidance of head contact with fast, rising balls kicked at close range can substantially reduce risk of subtle brain injury in players who head soccer balls.

  17. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Science.gov (United States)

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  18. Docetaxel in the treatment of squamous cell carcinoma of the head and neck

    Directory of Open Access Journals (Sweden)

    Alexander Rapidis

    2008-11-01

    Full Text Available Alexander Rapidis1, Nicholas Sarlis2, Jean-Louis Lefebvre3, Merrill Kies41Department of Maxillofacial Surgery, Greek Anticancer Institute, Saint Savvas Hospital, Athens, Greece; 2Department of Medical Affairs, Oncology – US Sanofi-Aventis, Bridgewater, NJ, USA; 3Head and Neck Department, Centre Régional de Lutte Contre le Cancer de Lille, Lille, France; 4Department of Thoracic/Head and Neck Medical Oncology, The University of Texas – M.D. Anderson Cancer Center, Houston, TX, USAAbstract: Squamous cell carcinoma of the head and neck (SCCHN presents at a locally advanced (LA stage in many patients. Chemotherapy has been successfully integrated into first-line treatment programs, either during or prior to radiotherapy (RT – the cornerstone modality for local disease control of inoperable disease or when organ preservation is desired. Concomitant chemoradiotherapy (CCRT provides an absolute survival benefit when compared with other types of locoregional therapy that exclude chemotherapy. Nonetheless, distant metastases still represent the most common cause of treatment failure. Consequently, adding induction chemotherapy (ICT to definitive non-surgical local therapies with a curative intent has been vigorously explored in LA SCCHN. Recently, it has been shown that ICT using the combination of the taxane docetaxel with cisplatin–5-fluorouracil provides significant survival benefit over cisplatin–5-FU, when used before either definitive RT (TAX323 trial or carboplatin-based CCRT (TAX324 trial. Docetaxel is also being investigated in metastatic or recurrent (M/R disease, with promising initial results. It is very likely that the future management strategies of SCCHN will incorporate biologic agents as an add-on to docetaxel-containing schemas, administered either as ICT prior to CCRT in the LA setting or for the management of M/R disease.Keywords: chemoradiotherapy, chemotherapy, docetaxel, head and neck carcinoma, induction, locally

  19. Association between temporomandibular disorders and abnormal head postures

    Directory of Open Access Journals (Sweden)

    Evandro Francisco FAULIN

    2015-01-01

    Full Text Available This study examines the possible correlation between the prevalence of temporomandibular disorders (TMD and different head postures in the frontal and sagittal planes using photographs of undergraduate students in the School of Dentistry at the Universidade de Brasília - UnB, Brazil. In this nonrandomized, cross-sectional study, the diagnoses of TMD were made with the Research Diagnostic Criteria (RDC/TMD axis I. The craniovertebral angle was used to evaluate forward head posture in the sagittal plane, and the interpupillary line was used to measure head tilt in the frontal plane. The measurements to evaluate head posture were made using the Software for the Assessment of Posture (SAPO. Students were divided into two study groups, based on the presence or absence of TMD. The study group comprised 46 students and the control group comprised 80 students. Data about head posture and TMD were analyzed with the Statistical Package for the Social Sciences, version 13. Most cases of TMD were classified as degenerative processes (group III, followed by disk displacement (group II and muscle disorders (group I. There was no sex predominance for the type of disorder. No association was found between prevalence rates for head postures in the frontal plane and the occurrence of TMD. The same result was found for the association of TMD diagnosis with craniovertebral angle among men and women, and the group that contained both men and women. Abnormal head postures were common among individuals both with and without TMD. No association was found between head posture evaluated in the frontal and sagittal planes and TMD diagnosis with the use of RDC/TMD.

  20. The ultimate intrinsic signal-to-noise ratio of loop- and dipole-like current patterns in a realistic human head model.

    Science.gov (United States)

    Pfrommer, Andreas; Henning, Anke

    2018-03-13

    The ultimate intrinsic signal-to-noise ratio (UISNR) represents an upper bound for the achievable SNR of any receive coil. To reach this threshold a complete basis set of equivalent surface currents is required. This study systematically investigated to what extent either loop- or dipole-like current patterns are able to reach the UISNR threshold in a realistic human head model between 1.5 T and 11.7 T. Based on this analysis, we derived guidelines for coil designers to choose the best array element at a given field strength. Moreover, we present ideal current patterns yielding the UISNR in a realistic body model. We distributed generic current patterns on a cylindrical and helmet-shaped surface around a realistic human head model. We excited electromagnetic fields in the human head by using eigenfunctions of the spherical and cylindrical Helmholtz operator. The electromagnetic field problem was solved by a fast volume integral equation solver. At 7 T and above, adding curl-free current patterns to divergence-free current patterns substantially increased the SNR in the human head (locally >20%). This was true for the helmet-shaped and the cylindrical surface. On the cylindrical surface, dipole-like current patterns had high SNR performance in central regions at ultra-high field strength. The UISNR increased superlinearly with B0 in most parts of the cerebrum but only sublinearly in the periphery of the human head. The combination of loop and dipole elements could enhance the SNR performance in the human head at ultra-high field strength. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Effectiveness of isopropyl myristate/cyclomethicone D5 solution of removing cuticular hydrocarbons from human head lice (Pediculus humanus capitis

    Directory of Open Access Journals (Sweden)

    Barnett Eric

    2012-09-01

    Full Text Available Abstract Background In the treatment of human head lice infestation, healthcare providers are increasingly concerned about lice becoming resistant to existing pesticide treatments. Traditional pesticides, used to control these pests, have a neurological mechanism of action. This publication describes a topical solution with a non-traditional mechanism of action, based on physical disruption of the wax layer that covers the cuticle of the louse exoskeleton. This topical solution has been shown clinically to cure 82% of patients with only a 10-minute treatment time, repeated once after 7 days. All insects, including human head lice, have a wax-covered exoskeleton. This wax, composed of hydrocarbons, provides the insect with protection against water loss and is therefore critical to its survival. When the protective wax is disrupted, water loss becomes uncontrollable and irreversible, leading to dehydration and death. A specific pattern of hydrocarbons has been found in all of the head louse cuticular wax studied. Iso-octane effectively removes these hydrocarbons from human head lice’s cuticular wax. Methods A method of head louse cuticle wax extraction and analysis by gas chromatography was developed. Human head lice (Pediculus humanus capitis were collected from infested patients and subjected to any of three extraction solvents comprising either the test product or one of two solvents introduced as controls. A gas chromatograph equipped with a flame ionization detector (GC/FID was used to determine the presence of hydrocarbons in the three head lice extracts. Results In the study reported herein, the test product isopropyl myristate/cyclomethicone D5 (IPM/D5 was shown to perform comparably with iso-octane, effectively extracting the target hydrocarbons from the cuticular wax that coats the human head louse exoskeleton. Conclusions Disruption of the integrity of the insect cuticle by removal of specific hydrocarbons found in the cuticular wax

  2. Actors with Multi-Headed Message Receive Patterns

    DEFF Research Database (Denmark)

    Sulzmann, Martin; Lam, Edmund Soon Lee; Van Weert, Peter

    2008-01-01

    style actors with receive clauses containing multi-headed message patterns. Patterns may be non-linear and constrained by guards. We provide a number of examples to show the usefulness of the extension. We also explore the design space for multi-headed message matching semantics, for example first-match......The actor model provides high-level concurrency abstractions to coordinate simultaneous computations by message passing. Languages implementing the actor model such as Erlang commonly only support single-headed pattern matching over received messages. We propose and design an extension of Erlang...... and rule priority-match semantics. The various semantics are inspired by the multi-set constraint matching semantics found in Constraint Handling Rules. This provides us with a formal model to study actors with multi-headed message receive patterns. The system can be implemented efficiently and we have...

  3. TMI-2 Vessel Investigation Project integration report

    International Nuclear Information System (INIS)

    Wolf, J.R.; Rempe, J.L.; Stickler, L.A.; Korth, G.E.; Diercks, D.R.; Neimark, L.A.; Akers, D.W.; Schuetz, B.K.; Shearer, T.L.; Chavez, S.A.; Thinnes, G.L.; Witt, R.J.; Corradini, M.L.; Kos, J.A.

    1994-03-01

    The Three Mile Island Unit 2 (TMI-2) Vessel Investigation Project (VIP) was an international effort that was sponsored by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development. The primary objectives of the VIP were to extract and examine samples from the lower head and to evaluate the potential modes of failure and the margin of structural integrity that remained in the TMI-2 reactor vessel during the accident. This report presents a summary of the major findings and conclusions that were developed from research during the VIP. Results from the various elements of the project are integrated to form a cohesive understanding of the vessel's condition after the accident

  4. TMI-2 Vessel Investigation Project integration report

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J. R.; Rempe, J. L.; Stickler, L. A.; Korth, G. E.; Diercks, D. R.; Neimark, L. A.; Akers, D W; Schuetz, B. K.; Shearer, T L; Chavez, S. A.; Thinnes, G. L.; Witt, R. J.; Corradini, M L; Kos, J. A. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-03-01

    The Three Mile Island Unit 2 (TMI-2) Vessel Investigation Project (VIP) was an international effort that was sponsored by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development. The primary objectives of the VIP were to extract and examine samples from the lower head and to evaluate the potential modes of failure and the margin of structural integrity that remained in the TMI-2 reactor vessel during the accident. This report presents a summary of the major findings and conclusions that were developed from research during the VIP. Results from the various elements of the project are integrated to form a cohesive understanding of the vessel`s condition after the accident.

  5. Head Trauma in Mixed Martial Arts.

    Science.gov (United States)

    Hutchison, Michael G; Lawrence, David W; Cusimano, Michael D; Schweizer, Tom A

    2014-06-01

    Mixed martial arts (MMA) is a full combative sport with a recent global increase in popularity despite significant scrutiny from medical associations. To date, the empirical research of the risk of head injuries associated with this sport is limited. Youth and amateur participation is growing, warranting investigation into the burden and mechanism of injuries associated with this sport. (1) To determine the incidence, risk factors, and characteristics of knockouts (KOs) and technical knockouts (TKOs) from repetitive strikes in professional MMA; and (2) to identify the mechanisms of head trauma and the situational factors that lead to KOs and TKOs secondary to repetitive strikes through video analysis. Descriptive epidemiology study. Competition data and video records for all KOs and TKOs from numbered Ultimate Fighting Championship MMA events (n = 844) between 2006 to 2012. Analyses included (1) multivariate logistic regression to investigate factors associated with an increased risk of sustaining a KO or TKO secondary to repetitive strikes and (2) video analysis of all KOs and TKOs secondary to repetitive strikes with descriptive statistics. During the study period, the KO rate was 6.4 per 100 athlete-exposures (AEs) (12.7% of matches), and the rate of TKOs secondary to repetitive strikes was 9.5 per 100 AEs (19.1% of matches), for a combined incidence of match-ending head trauma of 15.9 per 100 AEs (31.9% of matches). Logistic regression identified that weight class, earlier time in a round, earlier round in a match, and older age were risk factors for both KOs and TKOs secondary to repetitive strikes. Match significance and previously sustained KOs or TKOs were also risk factors for KOs. Video analysis identified that all KOs were the result of direct impact to the head, most frequently a strike to the mandibular region (53.9%). The average time between the KO-strike and match stoppage was 3.5 seconds (range, 0-20 seconds), with losers sustaining an average of 2

  6. Head and Neck Cancer—Health Professional Version

    Science.gov (United States)

    Head and neck cancers include hypopharyngeal, laryngeal, lip and oral cavity, metastatic squamous neck, nasopharyngeal, oropharyngeal, paranasal sinus, and salivary gland cancers. Find evidence-based information on head and neck cancer treatment, causes and prevention, research, screening, and statistics.

  7. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head.

    Science.gov (United States)

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure. A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13 th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

  8. Topiramate Responsive Exploding Head Syndrome

    OpenAIRE

    Palikh, Gaurang M.; Vaughn, Bradley V.

    2010-01-01

    Exploding head syndrome is a rare phenomenon but can be a significant disruption to quality of life. We describe a 39-year-old female with symptoms of a loud bang and buzz at sleep onset for 3 years. EEG monitoring confirmed these events occurred in transition from stage 1 sleep. This patient reported improvement in intensity of events with topiramate medication. Based on these results, topiramate may be an alternative method to reduce the intensity of events in exploding head syndrome.

  9. Topiramate responsive exploding head syndrome.

    Science.gov (United States)

    Palikh, Gaurang M; Vaughn, Bradley V

    2010-08-15

    Exploding head syndrome is a rare phenomenon but can be a significant disruption to quality of life. We describe a 39-year-old female with symptoms of a loud bang and buzz at sleep onset for 3 years. EEG monitoring confirmed these events occurred in transition from stage 1 sleep. This patient reported improvement in intensity of events with topiramate medication. Based on these results, topiramate may be an alternative method to reduce the intensity of events in exploding head syndrome.

  10. Interpretation of Gamma Index for Quality Assurance of Simultaneously Integrated Boost (SIB) IMRT Plans for Head and Neck Carcinoma

    Science.gov (United States)

    Atiq, Maria; Atiq, Atia; Iqbal, Khalid; Shamsi, Quratul ain; Andleeb, Farah; Buzdar, Saeed Ahmad

    2017-12-01

    Objective: The Gamma Index is prerequisite to estimate point-by-point difference between measured and calculated dose distribution in terms of both Distance to Agreement (DTA) and Dose Difference (DD). This study aims to inquire what percentage of pixels passing a certain criteria assure a good quality plan and suggest gamma index as efficient mechanism for dose verification of Simultaneous Integrated Boost Intensity Modulated Radiotherapy plans. Method: In this study, dose was calculated for 14 head and neck patients and IMRT Quality Assurance was performed with portal dosimetry using the Eclipse treatment planning system. Eclipse software has a Gamma analysis function to compare measured and calculated dose distribution. Plans of this study were deemed acceptable when passing rate was 95% using tolerance for Distance to agreement (DTA) as 3mm and Dose Difference (DD) as 5%. Result and Conclusion: Thirteen cases pass tolerance criteria of 95% set by our institution. Confidence Limit for DD is 9.3% and for gamma criteria our local CL came out to be 2.0% (i.e., 98.0% passing). Lack of correlation was found between DD and γ passing rate with R2 of 0.0509. Our findings underline the importance of gamma analysis method to predict the quality of dose calculation. Passing rate of 95% is achieved in 93% of cases which is adequate level of accuracy for analyzed plans thus assuring the robustness of SIB IMRT treatment technique. This study can be extended to investigate gamma criteria of 5%/3mm for different tumor localities and to explore confidence limit on target volumes of small extent and simple geometry.

  11. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].

    Science.gov (United States)

    Miyajima, Ryuichi; Fujibuchi, Toshioh; Miyachi, Yusuke; Tateishi, Satoshi; Uno, Yoshinori; Amakawa, Kazutoshi; Ohura, Hiroki; Orita, Shinichi

    2018-01-01

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm during abdominal CT. The maximum dose to the crystalline lens was approximately 600 μSv during head CT. We found that the use of volumetric CT scanning and X-ray protective goggles, and face direction toward the gantry reduced the exposure dose, particularly to the crystalline lens, for which lower equivalent dose during CT scan has been recently recommended in the International Commission on Radiological Protection Publication 118.

  12. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  13. Mechanical analysis of ceramic head for modular hip prosthesis

    International Nuclear Information System (INIS)

    Ravagli, E.

    1995-03-01

    A study, performed with the department of orthopaedics of the Rome Catholic University, has found out the two possible parameters mainly responsible for head breaking, i. e. errors in conical mating between head and stem, and cracks in the heads. This study has been continued in the frame of the STRIDE-CETMA project, aimed at founding and developing a centre for technologically advanced materials in Brindisi Technology Park (Italy). This report starts a systematic mechanical analysis of the above mentioned head, with the purpose of characterizing it exhaustively. The evaluations made lead to the conclusion that in nomimal conditions, the head is largely overdimensioned, taking into account the maximum load applied to the prosthesis

  14. Prismatic TIR (total internal reflection) low-concentration PV (photovoltaics)-integrated façade for low latitudes

    International Nuclear Information System (INIS)

    Sabry, Mohamed

    2016-01-01

    Low-concentration Façade-integrated Photovoltaic system in the form of TIR (total internal reflection) prismatic segmented façade could play an effective role in reducing the direct component of solar radiation transmitting through buildings, hence reducing both cooling and artificial lighting load on such buildings. A prismatic segmented façade is capable of allowing diffused skylight to transmit through it to the building interior, while preventing most of the direct solar radiation and converting it into clean energy by means of the integrated PV (​photovoltaics) cells. A range of prismatic TIR segmented façades with different head angles has been designed based on the geographical latitude of the chosen location. Each façade configuration is simulated by ray-tracing technique and its performance is investigated against realistic direct solar radiation data in two clear sky days representing summer and winter of the targeted location. Ray tracing simulations revealed that all of the selected configurations could collect most of the direct solar radiation in summer. In contrary, larger head angle of the segmented façade could collect wider intervals around the noon time till reaching a head angle of 23° at which most of the incident direct solar radiation could be collected. - Highlights: • 5 different head angles of prismatic segmented PV-integrated Façade are ray-traced. • Transmitted and PV-collected solar radiation percentages are determined. • DNI daily profiles with associated solar altitudes and azimuth data are simulated. • Expected transmitted and PV collected solar radiation are calculated for the proposed segments.

  15. Eye and head movements shape gaze shifts in Indian peafowl.

    Science.gov (United States)

    Yorzinski, Jessica L; Patricelli, Gail L; Platt, Michael L; Land, Michael F

    2015-12-01

    Animals selectively direct their visual attention toward relevant aspects of their environments. They can shift their attention using a combination of eye, head and body movements. While we have a growing understanding of eye and head movements in mammals, we know little about these processes in birds. We therefore measured the eye and head movements of freely behaving Indian peafowl (Pavo cristatus) using a telemetric eye-tracker. Both eye and head movements contributed to gaze changes in peafowl. When gaze shifts were smaller, eye movements played a larger role than when gaze shifts were larger. The duration and velocity of eye and head movements were positively related to the size of the eye and head movements, respectively. In addition, the coordination of eye and head movements in peafowl differed from that in mammals; peafowl exhibited a near-absence of the vestibulo-ocular reflex, which may partly result from the peafowl's ability to move their heads as quickly as their eyes. © 2015. Published by The Company of Biologists Ltd.

  16. A new 3-dimensional head fixation device for brain imaging

    International Nuclear Information System (INIS)

    Goto, Ryoi; Kawashima, Ryuta; Yoshioka, Seiro; Ono, Shuichi; Ito, Hiroshi; Sato, Kazunori; Akaizawa, Takashi; Koyama, Masamichi; Fukuda, Hiroshi

    1995-01-01

    We have developed a new head fixation device for studies of brain function. This device was designed to immobilize subject's heads during image scanning and to precisely reproduce the head position for two different imaging modalities such as MRI and PET. The device consists of a plastic frame, a pillow filled with beads of styrene foam, and a face mask of thermoplastic resin which was originally intended for application in radiotherapy. A bridge for biting was incorporated into the mask for stable fixation. The device enables immobilization of subject's heads with good reproducibility of position at the practical level. Our results indicate that this head fixation system is useful for fixation of head during activation studies using PET. (author)

  17. Interwoven fluctuations during intermodal perception: fractality in head sway supports the use of visual feedback in haptic perceptual judgments by manual wielding.

    Science.gov (United States)

    Kelty-Stephen, Damian G; Dixon, James A

    2014-12-01

    Intermodal integration required for perceptual learning tasks is rife with individual differences. Participants vary in how they use perceptual information to one modality. One participant alone might change her own response over time. Participants vary further in their use of feedback through one modality to inform another modality. Two experiments test the general hypothesis that perceptual-motor fluctuations reveal both information use within modality and coordination among modalities. Experiment 1 focuses on perceptual learning in dynamic touch, in which participants use exploratory hand-wielding of unseen objects to make visually guided length judgments and use visual feedback to rescale their judgments of the same mechanical information. Previous research found that the degree of fractal temporal scaling (i.e., "fractality") in hand-wielding moderates the use of mechanical information. Experiment 1 shows that head-sway fractality moderates the use of visual information. Further, experience with feedback increases head-sway fractality and prolongs its effect on later hand-wielding fractality. Experiment 2 replicates effects of head-sway fractality moderating use of visual information in a purely visual-judgment task. Together, these findings suggest that fractal fluctuations may provide a modal-general window onto not just how participants use perceptual information but also how well they may integrate information among different modalities. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  18. SmoothMoves : Smooth pursuits head movements for augmented reality

    NARCIS (Netherlands)

    Esteves, Augusto; Verweij, David; Suraiya, Liza; Islam, Rasel; Lee, Youryang; Oakley, Ian

    2017-01-01

    SmoothMoves is an interaction technique for augmented reality (AR) based on smooth pursuits head movements. It works by computing correlations between the movements of on-screen targets and the user's head while tracking those targets. The paper presents three studies. The first suggests that head

  19. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  20. Magnetic Force Microscopy Observation of Perpendicular Recording Head Remanence

    Science.gov (United States)

    Dilekrojanavuti, P.; Saengkaew, K.; Cheowanish, I.; Damrongsak, B.

    2017-09-01

    In this work, magnetic force microscopy (MFM) was utilized to observe the magnetic write head remanence, which is the remaining out-of-plane magnetic field on magnetic write heads after a write current is turned off. This remnant field can write unwanted tracks or erase written tracks on a magnetic media. The write head remanence can also occur from device and slider fabrication, either by applying current to the write coil during the inspection or biasing the external magnetic field to magnetic recording heads. This remanence can attract magnetic nanoparticles, which is suspended in cleaning water or surrounding air, and cause device contamination. MFM images were used to examine locations of the remnant field on the surface of magnetic recording heads. Experimental results revealed that the remanence occurred mostly on the shield and is dependent on the initial direction of magnetic moments. In addition, we demonstrated a potential use of MFM imaging to investigate effects of different etching gases on the head remanence.

  1. PEDIATRIC HEAD INJURIES, MECHANISM TO MANAGEMENT: EXPERIENCE OF A SINGLE CENTER

    Directory of Open Access Journals (Sweden)

    Pankaj

    2016-01-01

    Full Text Available INTRODUCTION Head injury is very common in modern life. Patients of any age group may have head injury however mechanism of head injury, pathophysiology and outcome of head injury is quite different in adults as compared to children. Road traffic accident is a common mode of head injury in adults while fall from height and household abuse is common mode in children. In Western countries, there is a separate registry system for pediatric head injury but there is no such system exist in india. Our present study is focused on pediatric head injury and evaluation of factors that affect the final outcome in pediatric patients.

  2. Scientific Integrity Policy Creation and Implementation.

    Science.gov (United States)

    Koizumi, K.

    2017-12-01

    Ensuring the integrity of science was a priority for the Obama Administration. In March 2009, President Obama issued a Presidential Memorandum that recognized the need for the public to be able to trust the science and scientific process informing public policy decisions. In 2010, the White House Office of Science and Technology Policy (OSTP) issued a Memorandum providing guidelines for Federal departments and agencies to follow in developing scientific integrity policies. This Memorandum describes minimum standards for: (1) strengthening the foundations of scientific integrity in government, including by shielding scientific data and analysis from inappropriate political influence; (2) improving public communication about science and technology by promoting openness and transparency; (3) enhancing the ability of Federal Advisory Committees to provide independent scientific advice; and (4) supporting the professional development of government scientists and engineers. The Memorandum called upon the heads of departments and agencies to develop scientific integrity policies that meet these requirements. At the end of the Obama Administration, 24 Federal departments and agencies had developed and implemented scientific integrity policies consistent with the OSTP guidelines. This year, there are significant questions as to the Trump Administration's commitment to these scientific integrity policies and interest in the Congress in codifying these policies in law. The session will provide an update on the status of agency scientific integrity policies and legislation.

  3. Development of simplified 1D and 2D models for studying a PWR lower head failure under severe accident conditions

    International Nuclear Information System (INIS)

    Koundy, V.; Dupas, J.; Bonneville, H.; Cormeau, I.

    2005-01-01

    In the study of severe accidents of nuclear pressurized water reactors, the scenarios that describe the relocation of significant quantities of liquid corium at the bottom of the lower head are investigated from the mechanical point of view. In these scenarios, the risk of a breach and the possibility of a large quantity of corium being released from the lower head exist. This may lead to direct heating of the containment or outer vessel steam explosion. These issues are important due to their early containment failure potential. Since the TMI-2 accident, many theoretical and experimental investigations, relating to lower head mechanical behaviour under severe thermo-mechanical loading in the event of a core meltdown accident have been performed. IRSN participated actively in the one-fifth scale USNRC/SNL LHF and OECD LHF (OLHF) programs. Within the framework of these programs, two simplified models were developed by IRSN: the first is a simplified 1D approach based on the theory of pressurized spherical shells and the second is a simplified 2D model based on the theory of shells of revolution under symmetric loading. The mathematical formulation of both models and the creep constitutive equations used are presented in detail in this paper. The corresponding models were used to interpret some of the OLHF program experiments and the calculation results were quite consistent with the experimental data. The two simplified models have been used to simulate the thermo-mechanical behaviour of a 900 MWe pressurized water reactor lower head under severe accident conditions leading to failure. The average transient heat flux produced by the corium relocated at the bottom of the lower head has been determined using the IRSN HARAR code. Two different methods, both taking into account the ablation of the internal surface, are used to determine the temperature profiles across the lower head wall and their effect on the time to failure is discussed. Using these simplified models

  4. Transfer Pricing; Charging of head office costs

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Joergen

    1998-07-01

    The key issues discussed in this presentation are (1) What are head office costs?, (2) Why is the charging an area of concern for international companies?, (3) Which part of head office costs should be charged?, (4) OECD guidelines on charging. Head office costs are classified as Shareholder costs, Stewardship costs, Costs related to a specific subsidiary or group of subsidiaries (on call), and Costs related to operational activities in the parent company. The OECD reports of 1984 and 1996 are discussed. In Norsk Hydro's experience, the practising of the OECD guidelines by national authorities are confusing and not consistent over time or across borders. To get a better understanding of how charging of corporate head office costs are dealt with on an international level, Norsk Hydro asked Deloitte and Touche in London to carry out a study on international companies' behaviour. Their conclusions are included.

  5. Challenges in the management of support and care programmes for child-headed households in South Africa.

    Science.gov (United States)

    Human, Sarie P; van Rensburg, Gisela H

    2011-10-01

    The present study reports on data collected in a larger study on 'A situational analysis of child-headed households in South Africa'. The purpose of this study was to explore the management and control of available and required services, resources and safety nets for children in child-headed households. The significance of having a better understanding of the challenges, limitations but importance for government structures to manage and control programmes will enhance the implementation and maintenance of focused and sustainable support structures and programmes which will effectively address the needs of child-headed households. An exploratory and descriptive, quantitative survey was conducted to provide information on government structures at a national level and the nine provinces in South Africa. The population consisted of the Departments of Social Development, Education, Health and Agriculture, at both national and provincial levels. The main findings included a lack of clarity regarding the concept and definition of a child-headed household, lack of empirical data, a diversity of needs and challenges in terms of location and geographical distribution of available infrastructure and support systems; programmes that are not inclusive and integrated; and contradictions in the stipulations and implementation of existing policies and capacity and human resources shortages. It was concluded that the magnitude, uniqueness and complexity of the phenomenon necessitate effective and sound scientific management principles. This is achieved by providing legal clarity of the concept; developing relevant policies and ensuring effective implementation thereof; rigorous monitoring and evaluation based on comprehensive empirical data; and protecting the rights and safety of these children and ensuring an enabling environment for all stakeholders to address needs and challenges. The role of the nurse manager is to ensure a holistic approach to children living in child-headed

  6. An Integrated Intrusion Detection Model of Cluster-Based Wireless Sensor Network.

    Science.gov (United States)

    Sun, Xuemei; Yan, Bo; Zhang, Xinzhong; Rong, Chuitian

    2015-01-01

    Considering wireless sensor network characteristics, this paper combines anomaly and mis-use detection and proposes an integrated detection model of cluster-based wireless sensor network, aiming at enhancing detection rate and reducing false rate. Adaboost algorithm with hierarchical structures is used for anomaly detection of sensor nodes, cluster-head nodes and Sink nodes. Cultural-Algorithm and Artificial-Fish-Swarm-Algorithm optimized Back Propagation is applied to mis-use detection of Sink node. Plenty of simulation demonstrates that this integrated model has a strong performance of intrusion detection.

  7. Parallel Solver for Diffuse Optical Tomography on Realistic Head Models With Scattering and Clear Regions.

    Science.gov (United States)

    Placati, Silvio; Guermandi, Marco; Samore, Andrea; Scarselli, Eleonora Franchi; Guerrieri, Roberto

    2016-09-01

    Diffuse optical tomography is an imaging technique, based on evaluation of how light propagates within the human head to obtain the functional information about the brain. Precision in reconstructing such an optical properties map is highly affected by the accuracy of the light propagation model implemented, which needs to take into account the presence of clear and scattering tissues. We present a numerical solver based on the radiosity-diffusion model, integrating the anatomical information provided by a structural MRI. The solver is designed to run on parallel heterogeneous platforms based on multiple GPUs and CPUs. We demonstrate how the solver provides a 7 times speed-up over an isotropic-scattered parallel Monte Carlo engine based on a radiative transport equation for a domain composed of 2 million voxels, along with a significant improvement in accuracy. The speed-up greatly increases for larger domains, allowing us to compute the light distribution of a full human head ( ≈ 3 million voxels) in 116 s for the platform used.

  8. Adaptive algorithm of magnetic heading detection

    Science.gov (United States)

    Liu, Gong-Xu; Shi, Ling-Feng

    2017-11-01

    Magnetic data obtained from a magnetic sensor usually fluctuate in a certain range, which makes it difficult to estimate the magnetic heading accurately. In fact, magnetic heading information is usually submerged in noise because of all kinds of electromagnetic interference and the diversity of the pedestrian’s motion states. In order to solve this problem, a new adaptive algorithm based on the (typically) right-angled corridors of a building or residential buildings is put forward to process heading information. First, a 3D indoor localization platform is set up based on MPU9250. Then, several groups of data are measured by changing the experimental environment and pedestrian’s motion pace. The raw data from the attached inertial measurement unit are calibrated and arranged into a time-stamped array and written to a data file. Later, the data file is imported into MATLAB for processing and analysis using the proposed adaptive algorithm. Finally, the algorithm is verified by comparison with the existing algorithm. The experimental results show that the algorithm has strong robustness and good fault tolerance, which can detect the heading information accurately and in real-time.

  9. Unusual head and neck injury in elevator: autopsy study.

    Science.gov (United States)

    Eren, B; Türkmen, N; Dokgöz, H

    2012-10-01

    Industrial injuries related to auto-load-carrying vehicles were not frequently reported in the literature. Presented case was, 31-year-old male furniture worker. Deceased was found in awkward position in furniture workshop. Victim was observed on his knees in front of the elevator, head and neck lodged within openings of the elevator, and head and neck structures compressed-guillotined by the lower platform of the elevator were detected. We presented rare case of head and neck compression by elevator. Key words: head - neck - accidents - elevator - autopsy.

  10. Development of head and trunk mesoderm in the dogfish, Scyliorhinus torazame: I. Embryology and morphology of the head cavities and related structures.

    Science.gov (United States)

    Adachi, Noritaka; Kuratani, Shigeru

    2012-01-01

    Vertebrate head segmentation has attracted the attention of comparative and evolutionary morphologists for centuries, given its importance for understanding the developmental body plan of vertebrates and its evolutionary origin. In particular, the segmentation of the mesoderm is central to the problem. The shark embryo has provided a canonical morphological scheme of the head, with its epithelialized coelomic cavities (head cavities), which have often been regarded as head somites. To understand the evolutionary significance of the head cavities, the embryonic development of the mesoderm was investigated at the morphological and histological levels in the shark, Scyliorhinus torazame. Unlike somites and some enterocoelic mesodermal components in other vertebrates, the head cavities in S. torazame appeared as irregular cyst(s) in the originally unsegmented mesenchymal head mesoderm, and not via segmentation of an undivided coelom. The mandibular cavity appeared first in the paraxial part of the mandibular mesoderm, followed by the hyoid cavity, and the premandibular cavity was the last to form. The prechordal plate was recognized as a rhomboid roof of the preoral gut, continuous with the rostral notochord, and was divided anteroposteriorly into two parts by the growth of the hypothalamic primordium. Of those, the posterior part was likely to differentiate into the premandibular cavity, and the anterior part disappeared later. The head cavities and somites in the trunk exhibited significant differences, in terms of histological appearance and timing of differentiation. The mandibular cavity developed a rostral process secondarily; its homology to the anterior cavity reported in some elasmobranch embryos is discussed. © 2012 Wiley Periodicals, Inc.

  11. Primary tendinitis of the long head of the biceps.

    Science.gov (United States)

    Post, M; Benca, P

    1989-09-01

    Seventeen patients with chronic painful shoulders who showed evidence of isolated bicipital tendinitis involving only the extracapsular, intertubercular portion of the long head of the biceps were chosen for surgical treatment when conservative treatment failed. The patients were thought to have primary bicipital tendinitis. The latter condition is secondary to other shoulder pathologies. Thirteen patients had tenodeses and four patients had transfer of the long head of the biceps to the origin of the conjoined tendon. Overall, excellent and good results were noted in 94% of both groups of patients when the long head of the biceps was tenodesed or transferred. Whether or not the long head of the biceps is a significant depressor of the humeral head requires further investigation.

  12. Toward high-resolution optoelectronic retinal prosthesis

    Science.gov (United States)

    Palanker, Daniel; Huie, Philip; Vankov, Alexander; Asher, Alon; Baccus, Steven

    2005-04-01

    It has been already demonstrated that electrical stimulation of retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. Current retinal implants provide very low resolution (just a few electrodes), while several thousand pixels are required for functional restoration of sight. We present a design of the optoelectronic retinal prosthetic system that can activate a retinal stimulating array with pixel density up to 2,500 pix/mm2 (geometrically corresponding to a visual acuity of 20/80), and allows for natural eye scanning rather than scanning with a head-mounted camera. The system operates similarly to "virtual reality" imaging devices used in military and medical applications. An image from a video camera is projected by a goggle-mounted infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. Such a system provides a broad field of vision by allowing for natural eye scanning. The goggles are transparent to visible light, thus allowing for simultaneous utilization of remaining natural vision along with prosthetic stimulation. Optical control of the implant allows for simple adjustment of image processing algorithms and for learning. A major prerequisite for high resolution stimulation is the proximity of neural cells to the stimulation sites. This can be achieved with sub-retinal implants constructed in a manner that directs migration of retinal cells to target areas. Two basic implant geometries are described: perforated membranes and protruding electrode arrays. Possibility of the tactile neural stimulation is also examined.

  13. Nutrition Education Resources in North Carolina-Based Head Start Preschool Programs: Administrator and Teacher Perceptions of Availability and Use.

    Science.gov (United States)

    Lisson, Sarah; Goodell, L Suzanne; Dev, Dipti; Wilkerson, Kristi; Hegde, Archana V; Stage, Virginia C

    2016-10-01

    The purpose of this study was to provide new insight into common barriers to the availability and use of nutrition education (NE) resources in Head Start preschool programs based on administrator and teacher perceptions. In-depth, semistructured phone interviews (n = 63) were conducted with administrators (n = 31) and teachers (n = 32) from North Carolina-based Head Start programs. Interviews were audio-recorded and transcribed verbatim. Data were analyzed qualitatively using content analysis to identify common themes. Five emergent themes were identified within the areas of NE resource availability and use and barriers to NE resource availability and use. Participants expressed desire for greater organization of existing NE material resources, increased community support, and professional development opportunities for teachers specific to NE. Funding and time constraints were reported as affecting NE resources. Creative strategies for addressing NE resource availability and use and barriers (eg, NE integration with educational standards) in Head Start are needed. Copyright © 2016 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  14. "Head versus heart"

    Directory of Open Access Journals (Sweden)

    Paul Rozin

    2007-08-01

    Full Text Available Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this study that American adults and undergraduates are substantially less likely to acknowledge magical effects when the judgments involve money (amount willing to pay to avoid an ``unpleasant'' magical contact than they are when using preference or rating measures. We conclude that in ``head-heart'' conflicts of this type, money tips the balance towards the former, or, in other words, that money makes the mind less magical.

  15. Head-Disk Interface Technology: Challenges and Approaches

    Science.gov (United States)

    Liu, Bo

    Magnetic hard disk drive (HDD) technology is believed to be one of the most successful examples of modern mechatronics systems. The mechanical beauty of magnetic HDD includes simple but super high accuracy positioning head, positioning technology, high speed and stability spindle motor technology, and head-disk interface technology which keeps the millimeter sized slider flying over a disk surface at nanometer level slider-disk spacing. This paper addresses the challenges and possible approaches on how to further reduce the slider disk spacing whilst retaining the stability and robustness level of head-disk systems for future advanced magnetic disk drives.

  16. High-magnitude head impact exposure in youth football

    Science.gov (United States)

    Campolettano, Eamon T.; Gellner, Ryan A.; Rowson, Steven

    2018-01-01

    OBJECTIVE Even in the absence of a clinically diagnosed concussion, research suggests that neurocognitive changes may develop in football players as a result of frequent head impacts that occur during football games and practices. The objectives of this study were to determine the specific situations in which high-magnitude impacts (accelerations exceeding 40g) occur in youth football games and practices and to assess how representative practice activities are of games with regard to high-magnitude head impact exposure. METHODS A total of 45 players (mean age 10.7 ± 1.1 years) on 2 youth teams (Juniors [mean age 9.9 ± 0.6 years; mean body mass 38.9 ± 9.9 kg] and Seniors [mean age 11.9 ± 0.6 years; mean body mass 51.4 ± 11.8 kg]) wore helmets instrumented with accelerometer arrays to record head impact accelerations for all practices and games. Video recordings from practices and games were used to verify all high-magnitude head impacts, identify specific impact characteristics, and determine the amount of time spent in each activity. RESULTS A total of 7590 impacts were recorded, of which 571 resulted in high-magnitude head impact accelerations exceeding 40g (8%). Impacts were characterized based on the position played by the team member who received the impact, the part of the field where the impact occurred, whether the impact occurred during a game or practice play, and the cause of the impact. High-magnitude impacts occurred most frequently in the open field in both games (59.4%) and practices (67.5%). “Back” position players experienced a greater proportion of high-magnitude head impacts than players at other positions. The 2 teams in this study structured their practice sessions similarly with respect to time spent in each drill, but impact rates differed for each drill between the teams. CONCLUSIONS High-magnitude head impact exposure in games and practice drills was quantified and used as the basis for comparison of exposure in the 2 settings. In

  17. Heat exchanger, head and shell acceptance criteria

    International Nuclear Information System (INIS)

    Lam, P.S.; Sindelar, R.L.

    1992-09-01

    Instability of postulated flaws in the head component of the heat exchanger could not produce a large break, equivalent to a DEGB in the PWS piping, due to the configuration of the head and restraint provided by the staybolts. Rather, leakage from throughwall flaws in the head would increase with flaw length with finite leakage areas that are bounded by a post-instability flaw configuration. Postulated flaws at instability in the shell of the heat exchanger or in the cooling water nozzles could produce a large break in the Cooling Water System (CWS) pressure boundary. An initial analysis of flaw stability for postulated flaws in the heat exchanger head was performed in January 1992. This present report updates that analysis and, additionally, provides acceptable flaw configurations to maintain defined structural or safety margins against flaw instability of the external pressure boundary components of the heat exchanger, namely the head, shell, and cooling water nozzles. Structural and flaw stability analyses of the heat exchanger tubes, the internal pressure boundary of the heat exchangers or interface boundary between the PWS and CWS, were previously completed in February 1992 as part of the heat exchanger restart evaluation and are not covered in this report

  18. Catalogue of tooth brush head designs.

    Science.gov (United States)

    Voelker, Marsha A; Bayne, Stephen C; Liu, Ying; Walker, Mary P

    2013-06-01

    Manual toothbrushes (MTBs) and power toothbrushes (PTBs) are effective oral physiotherapy aids for plaque removal. End-rounded bristles are safer and reduce damage to oral tissues. Nylon bristles are more effective in plaque removal because the bristle is stiffer than natural bristles. In the last 10 years the number of options for MTBs and PTBs has expanded significantly and there is very little information providing a reference frame for the design characteristics of the heads. The present in vitro study characterized a variety of MTB and PTB heads to provide a reference library for other research comparisons which might be made. Various commercial MTB and PTB heads were used to characterize the following: bristle size, shape, diameter, number of tufts, number of bristles per tuft and surface characteristics. Photographs were collected from the side, at 45 degrees and the top of each toothbrush (TB) head using a scanning electron microscope and digital camera. Images were analyzed (Soft Imaging System) for bristle features and designs. One-way ANOVA (p ≤ 0.05) was performed to detect differences among TB types within MTB and PTB groups and between pooled values for MTB and PTB groups. There were significant differences (p ≤ 0.05) in toothbrush bristle diameter and bristle shape. In contrast, there were no significant differences between PTB vs. MTB in regards to bristle diameter, bristle count and tuft count. The results suggest that although there are wide variations in toothbrush head designs, significant differences were found only in relation to bristle diameter and shape.

  19. 49 CFR 572.142 - Head assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ... acceleration versus time history curve shall be unimodal, and the oscillations occurring after the main pulse... for testing. (3) Suspend the head assembly with its midsagittal plane in vertical orientation as shown... head in transverse alignment with the CG, shall be used to ensure that the head transverse plane is...

  20. Further observations on the "bobble-headed doll syndrome".

    OpenAIRE

    Dell, S

    1981-01-01

    Two patients are presented with a head-bobblng "tic" classically associated with a suprasellar cyst. The first of these showed hypothalamic, neuroendocrinological and limbic abnormalities not previously described, although with a classic arachnoidal suprasellar cyst. The second of these patients showed head-bobbling behaviour during the first years of life as a manifestation of one out of many episodes of ventricular shunt obstruction. This case is therefore the first reported whose head bobb...

  1. Modelling of waves propagation on irregular surfaces using ray tracing and GTD approaches: Application to head waves simulation in TOFD inspections for NDT

    International Nuclear Information System (INIS)

    Ferrand, Adrien; Darmon, Michel; Chatillon, Sylvain; Deschamps, Marc

    2014-01-01

    The Time of Flight Diffraction (TOFD) technique is a classical ultrasonic method used in ultrasonic non-destructive evaluation, which allows a precise positioning and a quantitative size evaluation of cracks in the inspected material. Among the typical phenomena arising in the current TOFD inspection, the so-called 'head wave' is the first contribution reaching the receiver. The head wave propagation on a planar interface is well known and identified as a critical refraction taking place on the material surface. On irregular surfaces, it has been shown that the head wave results from the melting of surface and bulk waves mechanisms and that surface irregularities are responsible for numerous diffractions of the incident head wave. To simulate such behaviour, a model has been developed using a ray tracing technique based on time of flight minimization (generalized Fermat's principle). It enables the calculation of the ray path and the corresponding time of flight of all waves propagating in the material, including the head wave. To obtain a complete propagation model for these waves (both trajectory and amplitude), the integration of Geometrical Theory of Diffraction (GTD) models is currently performed by coupling them with the ray-based approach discussed above.

  2. [Management abilities of the head surgeon: essential for survival!].

    Science.gov (United States)

    Jähne, J

    2012-04-01

    Due to increased economic challenges in the management of hospitals head surgeons do not only need excellent surgical expertise but also significant management qualities. The personality of head surgeons should include authenticity, sincerity, fairness and the ability to cooperate. Visionary leadership, strategic thinking and strategic management of the personnel are further prerequisites for success. Besides good abilities in communication head surgeons need knowledge of the operating figures for interpretation. To keep up with the own capabilities time and self-management is essential. A survival as head surgeon is likely if these qualities and abilities exist.

  3. Development and field performance of indy race car head impact padding.

    Science.gov (United States)

    Melvin, J W; Bock, H; Anderson, K; Gideon, T

    2001-11-01

    The close-fitting cockpit of the modern Indy car single seat race car has the potential to provide a high level of head and neck impact protection in rear and side impacts. Crash investigation has shown that a wide variety of materials have been used as the padding for these cockpits and, as a result, produced varying outcomes in crashes. Additionally, these pads have not always been positioned for optimal performance. The purpose of this study was to investigate the head impact performance of a variety of energy-absorbing padding materials under impact conditions typical of Indy car rear impacts and to identify superior materials and methods of improving their performance as race car head pads. An extensive series of tests with the helmeted Hybrid III test dummy head and neck on an impact mini-sled was conducted to explore head padding concepts. Following this, a performance specification for a simplified impact test using a rigid headform that simulates the helmeted head was developed and recommendations for performance levels of head padding based on biomechanical data on helmeted head impacts were made. In 1997, during the time that the head pad research was being performed, the Indy Racing League introduced a new chassis specification for their cars. There were a number of rear- and side-impact crashes during that season that resulted in seven severe head injuries. Examples of the head padding in those cars were included in the experimental study. The results of the head pad research were used to specify new padding materials that met the new biomechanical criteria. The placement of the head pads was also changed for better location of the padding. These changes instituted in 1998 have reduced the number of head injuries in crashes similar to or more severe than those of 1997 and have resulted in only occasional moderate head injuries (concussions) in the 1998 and 1999 seasons.

  4. A comparative study of the morphometry of sperm head components in cattle, sheep, and pigs with a computer-assisted fluorescence method

    Directory of Open Access Journals (Sweden)

    Jesús L Yániz

    2016-01-01

    Full Text Available The aim of this study was to compare the sperm nuclear and acrosomal morphometry of three species of domestic artiodactyls; cattle (Bos taurus, sheep (Ovis aries, and pigs (Sus scrofa. Semen smears of twenty ejaculates from each species were fixed and labeled with a propidium iodide-Pisum sativum agglutinin (PI/PSA combination. Digital images of the sperm nucleus, acrosome, and whole sperm head were captured and analyzed. The use of the PI/PSA combination and CASA-Morph fluorescence-based method allowed the capture, morphometric analysis, and differentiation of most sperm nuclei, acrosomes and whole heads, and the assessment of acrosomal integrity with a high precision in the three species studied. For the size of the head and nuclear area, the relationship between the three species may be summarized as bull > ram > boar. However, for the other morphometric parameters (length, width, and perimeter, there were differences in the relationships between species for sperm nuclei and whole sperm heads. Bull sperm acrosomes were clearly smaller than those in the other species studied and covered a smaller proportion of the sperm head. The acrosomal morphology, small in the bull, large and broad in the sheep, and large, long, and with a pronounced equatorial segment curve in the boar, was species-characteristic. It was concluded that there are clear variations in the size and shape of the sperm head components between the three species studied, the acrosome being the structure showing the most variability, allowing a clear distinction of the spermatozoa of each species.

  5. Replacement of Pork Meat with Pork Head Meat for Frankfurters

    Science.gov (United States)

    Choi, Yun-Sang; Hwang, Ko-Eun; Kim, Hyun-Wook; Song, Dong-Heon; Jeon, Ki-Hong; Park, Jong-Dae; Sung, Jung-Min; Kim, Young-Boong; Kim, Cheon-Jei

    2016-01-01

    The effect of reducing pork meat concentrations from 50% to 30% and replacing it with up to 20% pork head meat on chemical composition, cooking characteristics, physicochemical and textural properties, apparent viscosity, and sensory characteristics of frankfurters was determined. The highest moisture content in frankfurters was found in the control and T1 (frankfurter with 45% pork meat + 5% pork head). Protein and fat contents in frankfurters with pork head meat added were significantly (ppork head meat was increased from 0% to 20%, cooking loss, total expressible fluid separation, fat separation, and pH of frankfurters were increased, while the lightness, redness, yellowness, and apparent viscosity of frankfurters were decreased. Ash contents, cohesiveness, color, and tenderness of sensory characteristics of frankfurters added with different amounts of pork meat or pork head meat were not significantly (p>0.05) different from those of the control or there treatments. Frankfurters in T4 (frankfurter with 30% pork meat + 20% pork head) had the lowest (p0.05) from that in the control. Frankfurters with higher pork head meat concentrations had lower flavor, juiciness, and overall acceptability scores. Therefore, replacing pork meat with pork head meat in the formulation could successfully produce results similar to those of control frankfurters. The best results were obtained when 10% pork head meat was used to replace pork meat. PMID:27621683

  6. Modeling transient streaming potentials in falling-head permeameter tests.

    Science.gov (United States)

    Malama, Bwalya; Revil, André

    2014-01-01

    We present transient streaming potential data collected during falling-head permeameter tests performed on samples of two sands with different physical and chemical properties. The objective of the work is to estimate hydraulic conductivity (K) and the electrokinetic coupling coefficient (Cl ) of the sand samples. A semi-empirical model based on the falling-head permeameter flow model and electrokinetic coupling is used to analyze the streaming potential data and to estimate K and Cl . The values of K estimated from head data are used to validate the streaming potential method. Estimates of K from streaming potential data closely match those obtained from the associated head data, with less than 10% deviation. The electrokinetic coupling coefficient was estimated from streaming potential vs. (1) time and (2) head data for both sands. The results indicate that, within limits of experimental error, the values of Cl estimated by the two methods are essentially the same. The results of this work demonstrate that a temporal record of the streaming potential response in falling-head permeameter tests can be used to estimate both K and Cl . They further indicate the potential for using transient streaming potential data as a proxy for hydraulic head in hydrogeology applications. © 2013, National Ground Water Association.

  7. Sentence comprehension following moderate closed head injury in adults.

    Science.gov (United States)

    Leikin, Mark; Ibrahim, Raphiq; Aharon-Peretz, Judith

    2012-09-01

    The current study explores sentence comprehension impairments among adults following moderate closed head injury. It was hypothesized that if the factor of syntactic complexity significantly affects sentence comprehension in these patients, it would testify to the existence of syntactic processing deficit along with working-memory problems. Thirty-six adults (18 closed head injury patients and 18 healthy controls matched in age, gender, and IQ) participated in the study. A picture-sentence matching task together with various tests for memory, language, and reading abilities were used to explore whether sentence comprehension impairments exist as a result of a deficit in syntactic processing or of working-memory dysfunction. Results indicate significant impairment in sentence comprehension among adults with closed head injury compared with their non-head-injured peers. Results also reveal that closed head injury patients demonstrate considerable decline in working memory, short-term memory, and semantic knowledge. Analysis of the results shows that memory impairment and syntactic complexity contribute significantly to sentence comprehension difficulties in closed head injury patients. At the same time, the presentation mode (spoken or written language) was found to have no effect on comprehension among adults with closed head injury, and their reading abilities appear to be relatively intact.

  8. Exploding head syndrome: a case report.

    Science.gov (United States)

    Ganguly, Gautam; Mridha, Banshari; Khan, Asif; Rison, Richard Alan

    2013-01-01

    Exploding head syndrome (EHS) is a rare parasomnia in which affected individuals awaken from sleep with the sensation of a loud bang. The etiology is unknown, but other conditions including primary and secondary headache disorders and nocturnal seizures need to be excluded. A 57-year-old Indian male presented with four separate episodes of awakening from sleep at night after hearing a flashing sound on the right side of his head over the last 2 years. These events were described 'as if there are explosions in my head'. A neurologic examination, imaging studies, and a polysomnogram ensued, and the results led to the diagnosis of EHS. EHS is a benign, uncommon, predominately nocturnal disorder that is self-limited. No treatment is generally required. Reassurance to the patient is often all that is needed.

  9. Computerised tomographic patterns in patients with head injury at ...

    African Journals Online (AJOL)

    2011-04-15

    Apr 15, 2011 ... The clinical severity of head injury is classified based on ... head injury include road traffic accidents (RTA), assaults, ... information in the management of patients with head ... Materials and Methods ... The right cerebral hemisphere was involved in 13 cases .... Nerve palsies – 3rd, 5th, 6th cranial nerves. 3.

  10. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  11. Leadership styles in ethical dilemmas when head nurses make decisions.

    Science.gov (United States)

    Zydziunaite, V; Lepaite, D; Suominen, T

    2013-06-01

    The overlooked aspect in Lithuania is the dearth of leaders among head nurses, who bear the responsibility for decisions in ethical dilemmas. Understanding the application of leadership styles is fundamental to ensuring head nurses' abilities to influence outcomes for healthcare providers and patients. To identify the leadership styles applied by head nurses in decision making in ethical dilemmas on hospital wards. The data were collected by questionnaires completed by head nurses (n = 278) working in five major state-funded hospitals in each of the five regions of Lithuania. The data were analysed using SPSS 16.0, calculating descriptive statistics and analysis of variance. Head nurses apply democratic, affiliative, transformational and sustainable leadership styles when resolving ethical dilemmas. The application of leadership styles is associated not only with specific situations, but also with certain background factors, such as years of experience in a head nurse's position, ward specialization and the incidence of ethical dilemmas. Nurses having been in a head nurse's position over 10 years use primitive leadership styles, notably bureaucratic leadership, more often than do those head nurses with only a few years of experience in such a position. The results highlight the need for head nurses to reflect on their practices and to find new ways of learning from practice, colleagues and patients. Head nurses' managerial decisions due to their 'executive power' can turn into a new state-of-the-art leadership in nursing. © 2013 The Authors. International Nursing Review © 2013 International Council of Nurses.

  12. Effectiveness of eye armor during blast loading.

    Science.gov (United States)

    Bailoor, Shantanu; Bhardwaj, Rajneesh; Nguyen, Thao D

    2015-11-01

    Ocular trauma is one of the most common types of combat injuries resulting from the interaction of military personnel with improvised explosive devices. Ocular blast injury mechanisms are complex, and trauma may occur through various injury mechanisms. However, primary blast injuries (PBI) are an important cause of ocular trauma that may go unnoticed and result in significant damage to internal ocular tissues and visual impairment. Further, the effectiveness of commonly employed eye armor, designed for ballistic and laser protection, in lessening the severity of adverse blast overpressures (BOP) is unknown. In this paper, we employed a three-dimensional (3D) fluid-structure interaction computational model for assessing effectiveness of the eye armor during blast loading on human eyes and validated results against free field blast measurements by Bentz and Grimm (2013). Numerical simulations show that the blast waves focused on the ocular region because of reflections from surrounding facial features and resulted in considerable increase in BOP. We evaluated the effectiveness of spectacles and goggles in mitigating the pressure loading using the computational model. Our results corroborate experimental measurements showing that the goggles were more effective than spectacles in mitigating BOP loading on the eye. Numerical results confirmed that the goggles significantly reduced blast wave penetration in the space between the armor and the eyes and provided larger clearance space for blast wave expansion after penetration than the spectacles. The spectacles as well as the goggles were more effective in reducing reflected BOP at higher charge mass because of the larger decrease in dynamic pressures after the impact. The goggles provided greater benefit of reducing the peak pressure than the spectacles for lower charge mass. However, the goggles resulted in moderate, sustained elevated pressure loading on the eye, that became 50-100% larger than the pressure loading

  13. Porcine head response to blast.

    Science.gov (United States)

    Shridharani, Jay K; Wood, Garrett W; Panzer, Matthew B; Capehart, Bruce P; Nyein, Michelle K; Radovitzky, Raul A; Bass, Cameron R 'dale'

    2012-01-01

    Recent studies have shown an increase in the frequency of traumatic brain injuries related to blast exposure. However, the mechanisms that cause blast neurotrauma are unknown. Blast neurotrauma research using computational models has been one method to elucidate that response of the brain in blast, and to identify possible mechanical correlates of injury. However, model validation against experimental data is required to ensure that the model output is representative of in vivo biomechanical response. This study exposes porcine subjects to primary blast overpressures generated using a compressed-gas shock tube. Shock tube blasts were directed to the unprotected head of each animal while the lungs and thorax were protected using ballistic protective vests similar to those employed in theater. The test conditions ranged from 110 to 740 kPa peak incident overpressure with scaled durations from 1.3 to 6.9 ms and correspond approximately with a 50% injury risk for brain bleeding and apnea in a ferret model scaled to porcine exposure. Instrumentation was placed on the porcine head to measure bulk acceleration, pressure at the surface of the head, and pressure inside the cranial cavity. Immediately after the blast, 5 of the 20 animals tested were apneic. Three subjects recovered without intervention within 30 s and the remaining two recovered within 8 min following respiratory assistance and administration of the respiratory stimulant doxapram. Gross examination of the brain revealed no indication of bleeding. Intracranial pressures ranged from 80 to 390 kPa as a result of the blast and were notably lower than the shock tube reflected pressures of 300-2830 kPa, indicating pressure attenuation by the skull up to a factor of 8.4. Peak head accelerations were measured from 385 to 3845 G's and were well correlated with peak incident overpressure (R(2) = 0.90). One SD corridors for the surface pressure, intracranial pressure (ICP), and head acceleration are

  14. Optimised intake stroke analysis for flat and dome head pistons ...

    African Journals Online (AJOL)

    Optimised intake stroke analysis for flat and dome head pistons. ... in understanding the performance characteristics optioned between flat head and dome head pistons in engine design. ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. Effect of different head-neck-jaw postures on cervicocephalic kinesthetic sense.

    Science.gov (United States)

    Zafar, H; Alghadir, A H; Iqbal, Z A

    2017-12-01

    To investigate the effect of different induced head-neck-jaw postures on head-neck relocation error among healthy subjects. 30 healthy adult male subjects participated in this study. Cervicocephalic kinesthetic sense was measured while standing, habitual sitting, habitual sitting with clenched jaw and habitual sitting with forward head posture during right rotation, left rotation, flexion and extension using kinesthetic sensibility test. Head-neck relocation error was least while standing, followed by habitual sitting, habitual sitting with forward head posture and habitual sitting with jaw clenched. However, there was no significant difference in error between different tested postures during all the movements. To the best of our knowledge, this is the first study to see the effect of different induced head-neck-jaw postures on head-neck position sense among healthy subjects. Assuming a posture for a short duration of time doesn't affect head-neck relocation error in normal healthy subjects.

  16. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  17. Fall detection in the elderly by head-tracking

    OpenAIRE

    Yu, Miao; Naqvi, Syed Mohsen; Chambers, Jonathan

    2009-01-01

    In the paper, we propose a fall detection method based on head tracking within a smart home environment equipped with video cameras. A motion history image and code-book background subtraction are combined to determine whether large movement occurs within the scene. Based on the magnitude of the movement information, particle filters with different state models are used to track the head. The head tracking procedure is performed in two video streams taken bytwoseparatecamerasandthree-dimension...

  18. Head Start Participants, Programs, Families and Staff in 2013

    Science.gov (United States)

    Walker, Christina

    2014-01-01

    Head Start programs provide poor children and their families with comprehensive early education and support services. Each year, programs are required to submit a Program Information Report (PIR) to the Office of Head Start on participating children, pregnant women, and families, as well as the staff serving the Head Start population. In 2013, the…

  19. Topographic Pattern Distribution of Head And Neck Squamous Cell ...

    African Journals Online (AJOL)

    FINEPRINT

    value of 71% of SCC in Turkey. Nevertheless a similar report documented a relatively lower value especially in. Yemen where head and neck SCC constituted only 8% of all head and neck cancers. Reports from Yemen revealed that oral cavity SCC was the most common topographic site of all head and. 3 neck cancers.

  20. The Role of the Primary School Head.

    Science.gov (United States)

    Davies, Lester

    1987-01-01

    This study uses Henry Mintzberg's structural observation method to examine British primary school head teachers' work patterns and determine the nature of their role. Head teachers' days were characterized by brevity, variety, and fragmentation similar to those discussed in findings of other empirical managerial studies. Leadership roles stressed…

  1. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  2. Three-dimensional interactive and stereotactic atlas of head muscles and glands correlated with cranial nerves and surface and sectional neuroanatomy.

    Science.gov (United States)

    Nowinski, Wieslaw L; Chua, Beng Choon; Johnson, Aleksandra; Qian, Guoyu; Poh, Lan Eng; Yi, Su Hnin Wut; Bivi, Aminah; Nowinska, Natalia G

    2013-04-30

    Three-dimensional (3D) relationships between head muscles and cranial nerves innervating them are complicated. Existing sources present these relationships in illustrations, radiologic scans, or autopsy photographs, which are limited for learning and use. Developed electronic atlases are limited in content, quality, functionality, and/or presentation. We create a truly 3D interactive, stereotactic and high quality atlas, which provides spatial relationships among head muscles, glands and cranial nerves, and correlates them to surface and sectional neuroanatomy. The head muscles and glands were created from a 3T scan by contouring them and generating 3D models. They were named and structured according to Terminologia anatomica. The muscles were divided into: extra-ocular, facial, masticatory and other muscles, and glands into mouth and other glands. The muscles, glands (and also head) were placed in a stereotactic coordinate system. This content was integrated with cranial nerves and neuroanatomy created earlier. To explore this complex content, a scalable user interface was designed with 12 modules including central nervous system (cerebrum, cerebellum, brainstem, spinal cord), cranial nerves, muscles, glands, arterial system, venous system, tracts, deep gray nuclei, ventricles, white matter, visual system, head. Anatomy exploration operations include compositing/decompositing, individual/group selection, 3D view-index mapping, 3D labeling, highlighting, distance measuring, 3D brain cutting, and axial/coronal/sagittal triplanar display. To our best knowledge, this is the first truly 3D, stereotactic, interactive, fairly complete atlas of head muscles, and the first attempt to create a 3D stereotactic atlas of glands. Its use ranges from education of students and patients to research to potential clinical applications. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  3. Assessment of New Marksmanship Strategies in 2010

    Science.gov (United States)

    2012-03-01

    and 4N (CCO used during the day; Night vision device/goggles and AN/ PAQ -4 aiming light used at night)   DAY FIRING PRONE SUPPORTED  PRONE...Boresighting/zeroing an aiming light ( PAQ / PEQ) Y N Did not perform b. Boresighting/zeroing a CCO % Soldiers responding to each option OSUT 1 OSUT...magazines while engaging targets Y N g. Engaging targets at night with an aiming light ( PAQ /PEQ) and night vision goggles/device Y N h. Engaging

  4. Schwannomas of the head and neck

    Directory of Open Access Journals (Sweden)

    Anastasios Kanatas

    2011-12-01

    Full Text Available Schwannomas are benign encapsulated nerve sheath tumors composed of Schwann cells. Malignant change in head and neck schwannomas is rare, with the incidence varying between 8 and 13.9%. In this review, we discuss the presentation and the management of head and neck schwannomas. The issues and difficulties based on our own experience as well as the experience of published reports from the literature are presented.

  5. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  6. Evaluation of head movement periodicity and irregularity during locomotion of Caenorhabditis elegans

    Directory of Open Access Journals (Sweden)

    Ryuzo eShingai

    2013-03-01

    Full Text Available Caenorhabditis elegans is suitable for studying the nervous system, which controls behavior. C. elegans shows sinusoidal locomotion on an agar plate. The head moves not only sinusoidally but also more complexly, which reflects regulation of the head muscles by the nervous system. The head movement becomes more irregular with senescence. To date, the head movement complexity has not been quantitatively analyzed. We propose two simple methods for evaluation of the head movement regularity on an agar plate using image analysis. The methods calculate metrics that are a measure of how the head end movement is correlated with body movement. In the first method, the length along the trace of the head end on the agar plate between adjacent intersecting points of the head trace and the quasi-midline of the head trace, which was made by sliding an averaging window of 1/2 the body wavelength, was obtained. Histograms of the lengths showed periodic movement of the head and deviation from it. In the second method, the intersections between the trace of the head end and the trace of the 5 (near the pharynx or 50% (the mid-body point from the head end in the centerline length of the worm image were marked. The length of the head trace between adjacent intersections was measured, and a histogram of the lengths was produced. The histogram for the 5% point showed deviation of the head end movement from the movement near the pharynx. The histogram for the 50% point showed deviation of the head movement from the sinusoidal movement of the body center. Application of these methods to wild type and several mutant strains enabled evaluation of their head movement periodicity and irregularity, and revealed a difference in the age-dependence of head movement irregularity between the strains. A set of five parameters obtained from the histograms reliably identifies differences in head movement between strains.

  7. Head movements and postures as pain behavior

    Science.gov (United States)

    Al-Hamadi, Ayoub; Limbrecht-Ecklundt, Kerstin; Walter, Steffen; Traue, Harald C.

    2018-01-01

    Pain assessment can benefit from observation of pain behaviors, such as guarding or facial expression, and observational pain scales are widely used in clinical practice with nonverbal patients. However, little is known about head movements and postures in the context of pain. In this regard, we analyze videos of three publically available datasets. The BioVid dataset was recorded with healthy participants subjected to painful heat stimuli. In the BP4D dataset, healthy participants performed a cold-pressor test and several other tasks (meant to elicit emotion). The UNBC dataset videos show shoulder pain patients during range-of-motion tests to their affected and unaffected limbs. In all videos, participants were sitting in an upright position. We studied head movements and postures that occurred during the painful and control trials by measuring head orientation from video over time, followed by analyzing posture and movement summary statistics and occurrence frequencies of typical postures and movements. We found significant differences between pain and control trials with analyses of variance and binomial tests. In BioVid and BP4D, pain was accompanied by head movements and postures that tend to be oriented downwards or towards the pain site. We also found differences in movement range and speed in all three datasets. The results suggest that head movements and postures should be considered for pain assessment and research. As additional pain indicators, they possibly might improve pain management whenever behavior is assessed, especially in nonverbal individuals such as infants or patients with dementia. However, in advance more research is needed to identify specific head movements and postures in pain patients. PMID:29444153

  8. Heading perception in patients with advanced retinitis pigmentosa

    Science.gov (United States)

    Li, Li; Peli, Eli; Warren, William H.

    2002-01-01

    PURPOSE: We investigated whether retinis pigmentosa (RP) patients with residual visual field of < 100 degrees could perceive heading from optic flow. METHODS: Four RP patients and four age-matched normally sighted control subjects viewed displays simulating an observer walking over a ground. In experiment 1, subjects viewed either the entire display with free fixation (full-field condition) or through an aperture with a fixation point at the center (aperture condition). In experiment 2, patients viewed displays of different durations. RESULTS: RP patients' performance was comparable to that of the age-matched control subjects: heading judgment was better in the full-field condition than in the aperture condition. Increasing display duration from 0.5 s to 1 s improved patients' heading performance, but giving them more time (3 s) to gather more visual information did not consistently further improve their performance. CONCLUSIONS: RP patients use active scanning eye movements to compensate for their visual field loss in heading perception; they might be able to gather sufficient optic flow information for heading perception in about 1 s.

  9. Risk factors for head injury events in professional rugby union: a video analysis of 464 head injury events to inform proposed injury prevention strategies.

    Science.gov (United States)

    Tucker, Ross; Raftery, Martin; Kemp, Simon; Brown, James; Fuller, Gordon; Hester, Ben; Cross, Matthew; Quarrie, Ken

    2017-08-01

    The tackle is responsible for the majority of head injuries during rugby union. In order to address head injury risk, risk factors during the tackle must first be identified. This study analysed tackle characteristics in the professional game in order to inform potential interventions. 464 tackles resulting in a head injury assessment (HIA) were analysed in detail, with tackle type, direction, speed, acceleration, nature of head contact and player body position the characteristics of interest. Propensity to cause an HIA was significantly greater for active shoulder tackles, front-on tackles, high speeder tackles and an accelerating tackler. Head contact between a tackler's head and ball carrier's head or shoulder was significantly more likely to cause an HIA than contact below the level of the shoulder (incident rate ratio (IRR) 4.25, 95%-CI 3.38 to 5.35). The tackler experiences the majority (78%) of HIAs when head-to-head contact occurs. An upright tackler was 1.5 times more likely to experience an HIA than a bent at the waist tackler (IRR 1.44, 95% CI 1.18 to 1.76). This study confirms that energy transfer in the tackle is a risk factor for head injury, since direction, type and speed all influence HIA propensity. The study provides evidence that body position and the height of tackles should be a focus for interventions, since lowering height and adopting a bent at the waist body position is associated with reduced risk for both tacklers and ball carriers. To this end, World Rugby has implemented law change based on the present data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    Science.gov (United States)

    Hirpara, Kieran Michael; O'Halloran, Emily; O'Sullivan, Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA's (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  11. Progress and status of the Integral Fast Reactor (IFR) development program

    International Nuclear Information System (INIS)

    Chang, Yoon I.

    1992-01-01

    In the Integral Fast Reactor (IFR) development program, the entire reactor system -- reactor, fuel cycle, and waste process is being developed and optimized at the same time as a single integral entity. The ALMR reactor plant design is being developed by an industrial team headed by General Electric and is presented in a companion paper. Detailed discussions on the present status of the IFR technology development activities in the areas of fuels, pyroprocessing, safety, core design, and fuel cycle demonstration are presented in the other two companion papers that follows this

  12. Progress and status of the Integral Fast Reactor (IFR) development program

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yoon I.

    1992-04-01

    In the Integral Fast Reactor (IFR) development program, the entire reactor system -- reactor, fuel cycle, and waste process is being developed and optimized at the same time as a single integral entity. The ALMR reactor plant design is being developed by an industrial team headed by General Electric and is presented in a companion paper. Detailed discussions on the present status of the IFR technology development activities in the areas of fuels, pyroprocessing, safety, core design, and fuel cycle demonstration are presented in the other two companion papers that follows this.

  13. Progress and status of the Integral Fast Reactor (IFR) development program

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yoon I.

    1992-01-01

    In the Integral Fast Reactor (IFR) development program, the entire reactor system -- reactor, fuel cycle, and waste process is being developed and optimized at the same time as a single integral entity. The ALMR reactor plant design is being developed by an industrial team headed by General Electric and is presented in a companion paper. Detailed discussions on the present status of the IFR technology development activities in the areas of fuels, pyroprocessing, safety, core design, and fuel cycle demonstration are presented in the other two companion papers that follows this.

  14. Stepladder Reconstructive Options in Post-Ablative Complex Surgical Defects in the Head and Neck

    International Nuclear Information System (INIS)

    EL MARAKBY, H.H.; NAGUIB, Sh.F.; EL-SAWY, A.F.; AMIN, A.A.

    2008-01-01

    Background: Reconstruction of head and neck defects can pose many challenges to the reconstructive head and neck surgeon. Achieving the best cosmetic and functional results without compromising the safety of oncologic surgery are the primary reconstructive goals. Speech and articulation are particularly important in oral reconstructive procedures. In addition, preservation of the integrity and function of the donor sites should always be considered in all reconstructive procedures. Aim of the Study: The aim of the study is to evaluate different reconstructive options in complex defects of the head and neck region after resection of malignant tumours. The feasibility of the reconstructive ladder starting from simple techniques such as local flaps and skin grafts up to free flaps will be assessed. Patients and Methods: In this study we evaluated different reconstructive procedures used in 50 patients with complex head and neck defects undertaken at the department of surgery at the National Cancer Institute between July 2003 and December 2007. Results: The average age of patients was 52 years and the range was 26-67 years. Most of the tumours were either squamous cell carcinoma (74%) or Basal cell carcinoma (20%). Tumour sites included the nose (6%), lip (10%), cheek (12%) scalp (6%) as well as mucosal defects of the oral cavity (40%) and the hypopharynx (20%). We used local flaps and skin grafts in reconstruction in 36% of cases and pedicled flaps in 32% while free flaps were used in 32% of cases. Complications occurred in 32% of patients of which total flaps loss constituted 6% and partial flap loss 4%. Minor complications such as oro-cutaneous fistulae, wound infection, seroma and haematoma were noticed in 22% and all of them were treated conservatively. The final functional and aesthetic results were satisfactory in 60% of cases while poor results were encountered in patients who suffered some degree of flap loss.

  15. Video incident analysis of head injuries in high school girls' lacrosse.

    Science.gov (United States)

    Caswell, Shane V; Lincoln, Andrew E; Almquist, Jon L; Dunn, Reginald E; Hinton, Richard Y

    2012-04-01

    Knowledge of injury mechanisms and game situations associated with head injuries in girls' high school lacrosse is necessary to target prevention efforts. To use video analysis and injury data to provide an objective and comprehensive visual record to identify mechanisms of injury, game characteristics, and penalties associated with head injury in girls' high school lacrosse. Descriptive epidemiology study. In the 25 public high schools of 1 school system, 529 varsity and junior varsity girls' lacrosse games were videotaped by trained videographers during the 2008 and 2009 seasons. Video of head injury incidents was examined to identify associated mechanisms and game characteristics using a lacrosse-specific coding instrument. Of the 25 head injuries (21 concussions and 4 contusions) recorded as game-related incidents by athletic trainers during the 2 seasons, 20 head injuries were captured on video, and 14 incidents had sufficient image quality for analysis. All 14 incidents of head injury (11 concussions, 3 contusions) involved varsity-level athletes. Most head injuries resulted from stick-to-head contact (n = 8), followed by body-to-head contact (n = 4). The most frequent player activities were defending a shot (n = 4) and competing for a loose ball (n = 4). Ten of the 14 head injuries occurred inside the 12-m arc and in front of the goal, and no penalty was called in 12 injury incidents. All injuries involved 2 players, and most resulted from unintentional actions. Turf versus grass did not appear to influence number of head injuries. Comprehensive video analysis suggests that play near the goal at the varsity high school level is associated with head injuries. Absence of penalty calls on most of these plays suggests an area for exploration, such as the extent to which current rules are enforced and the effectiveness of existing rules for the prevention of head injury.

  16. Exploding head syndrome is common in college students.

    Science.gov (United States)

    Sharpless, Brian A

    2015-08-01

    Exploding head syndrome is characterized by the perception of loud noises during sleep-wake or wake-sleep transitions. Although episodes by themselves are relatively harmless, it is a frightening phenomenon that may result in clinical consequences. At present there are little systematic data on exploding head syndrome, and prevalence rates are unknown. It has been hypothesized to be rare and to occur primarily in older (i.e. 50+ years) individuals, females, and those suffering from isolated sleep paralysis. In order to test these hypotheses, 211 undergraduate students were assessed for both exploding head syndrome and isolated sleep paralysis using semi-structured diagnostic interviews: 18.00% of the sample experienced lifetime exploding head syndrome, this reduced to 16.60% for recurrent cases. Though not more common in females, it was found in 36.89% of those diagnosed with isolated sleep paralysis. Exploding head syndrome episodes were accompanied by clinically significant levels of fear, and a minority (2.80%) experienced it to such a degree that it was associated with clinically significant distress and/or impairment. Contrary to some earlier theorizing, exploding head syndrome was found to be a relatively common experience in younger individuals. Given the potential clinical impacts, it is recommended that it be assessed more regularly in research and clinical settings. © 2015 European Sleep Research Society.

  17. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  18. A three dimensional children head database for acoustical research and development

    DEFF Research Database (Denmark)

    Harder, Stine; Paulsen, Rasmus Reinhold; Larsen, Martin

    2013-01-01

    Most computational-acoustic work within spatial hearing relies on head-related transfer functions from databases of measurements taken on adult humans or dummy heads. We aim to provide a set of 3D digital heads including children, from which head-related transfer functions can be computed instead...

  19. The importance of rotational kinematics in pedestrian head to windshield impacts

    NARCIS (Netherlands)

    Mordaka, J.; Kleiven, S.; Schijndel-de Nooij, M. van; Lange, R. de; Casanova, L.J.G.; Carter, E.L.; Holst, H. von

    2007-01-01

    The objective of the present study was to analyze the effect of angular kinematics on head injury in pedestrian head-to-windshield impacts. Three cases of pedestrian head impacts were simulated with FE head and windshield models. The initial impact conditions were obtained from pedestrian accident

  20. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...... patients. Young patients reported that smoking, alcohol, illegal drugs, sexuality, and contraception were addressed significantly more at adult clinics in comparison to pediatric clinics. After controlling for age, gender and duration of illness, according to young patients, adjusted odds ratios...

  1. MRI in head trauma

    International Nuclear Information System (INIS)

    Hong, Jin Kyo

    1986-01-01

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  2. MRI in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo [Shin Wha Hospital, Seoul (Korea, Republic of)

    1986-02-15

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  3. Where is Russia heading?

    Directory of Open Access Journals (Sweden)

    Natalija Pliskevič

    1999-10-01

    Full Text Available The author examines the proceedings from the collection Where is Russia Heading? (= Куда идёт Россия?, published between 1994 and 1998 in connection with the international symposium held under this name each year in Moscow. The symposia and their proceeding, involving leading Russian and foreign experts, were significant in that they encompassed a wide range of themes – social, economic, political, legislative, cultural and other transformations that have been occurring in Russia during the past decades. The author, however, limits her review to contributions dealing with ethno-political and socio-cultural transformations in Russia. She concludes that the question – “Where is Russia heading?” – still remains open to answers.

  4. Is there a relationship between head posture and craniomandibular pain?

    Science.gov (United States)

    Visscher, C M; De Boer, W; Lobbezoo, F; Habets, L L M H; Naeije, M

    2002-11-01

    An often-suggested factor in the aetiology of craniomandibular disorders (CMD) is an anteroposition of the head. However, the results of clinical studies to the relationship between CMD and head posture are contradictory. Therefore, the first aim of this study was to determine differences in head posture between well-defined CMD pain patients with or without a painful cervical spine disorder and healthy controls. The second aim was to determine differences in head posture between myogenous and arthrogenous CMD pain patients and controls. Two hundred and fifty persons entered the study. From each person, a standardized oral history was taken and blind physical examinations of the masticatory system and of the neck were performed. The participants were only included into one of the subgroups when the presence or absence of their symptoms was confirmed by the results of the physical examination. Head posture was quantified using lateral photographs and a lateral radiograph of the head and the cervical spine. After correction for age and gender effects, no difference in head posture was found between any of the patient and non-patient groups (P > 0.27). Therefore, this study does not support the suggestion that painful craniomandibular disorders, with or without a painful cervical spine disorder, are related to head posture.

  5. Evaluation of a pig femoral head osteonecrosis model

    Directory of Open Access Journals (Sweden)

    Kim Harry

    2010-03-01

    Full Text Available Abstract Background A major cause of osteonecrosis of the femoral head is interruption of a blood supply to the proximal femur. In order to evaluate blood circulation and pathogenetic alterations, a pig femoral head osteonecrosis model was examined to address whether ligature of the femoral neck (vasculature deprivation induces a reduction of blood circulation in the femoral head, and whether transphyseal vessels exist for communications between the epiphysis and the metaphysis. We also tested the hypothesis that the vessels surrounding the femoral neck and the ligamentum teres represent the primary source of blood flow to the femoral head. Methods Avascular osteonecrosis of the femoral head was induced in Yorkshire pigs by transecting the ligamentum teres and placing two ligatures around the femoral neck. After heparinized saline infusion and microfil perfusion via the abdominal aorta, blood circulation in the femoral head was evaluated by optical and CT imaging. Results An angiogram of the microfil casted sample allowed identification of the major blood vessels to the proximal femur including the iliac, common femoral, superficial femoral, deep femoral and circumflex arteries. Optical imaging in the femoral neck showed that a microfil stained vessel network was visible in control sections but less noticeable in necrotic sections. CT images showed a lack of microfil staining in the epiphysis. Furthermore, no transphyseal vessels were observed to link the epiphysis to the metaphysis. Conclusion Optical and CT imaging analyses revealed that in this present pig model the ligatures around the femoral neck were the primary cause of induction of avascular osteonecrosis. Since the vessels surrounding the femoral neck are comprised of the branches of the medial and the lateral femoral circumflex vessels, together with the extracapsular arterial ring and the lateral epiphyseal arteries, augmentation of blood circulation in those arteries will improve

  6. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  7. Nutrition in Patients with Head Trauma

    Directory of Open Access Journals (Sweden)

    Burcu Totur

    2013-01-01

    Full Text Available The need of energy increases by 40% in patients with a head trauma, when compared to people who are living a normal life. This ratio reaches to 200% in some cases. It is important to give a nutrition support which can satisfy the energy need resulted from the hypermetabolic and hypercatabolic states and that is enough to help to fix the immunologic state and achieve a better result in healing the injury. When oral nutrition is not possible in the patient with a head trauma, their energy need is satisfied through enteral and parenteral nutrition. Though parenteral nutrition had held an important role in feeding patients with head trauma, enteral nutrition is applied much more widely today. Enteral and parenteral nutrition both has their own advantages and disadvantages. In the clinical and laboratory studies that had been held, it was found that enteral nutrition improved the systemic immunity, decreased the incidence of the major infectious complications, decreased the metabolic response to trauma, protected the intestinal mucosa, and protected the ecologic balance of the microflora. In this article, it is investigated through the importance of the feeding in patients with a head trauma and reasons to chose enteral nutrition

  8. The Science of Racing against Opponents: Affordance Competition and the Regulation of Exercise Intensity in Head-to-Head Competition.

    Science.gov (United States)

    Hettinga, Florentina J; Konings, Marco J; Pepping, Gert-Jan

    2017-01-01

    Athlete-environment interactions are crucial factors in understanding the regulation of exercise intensity in head-to-head competitions. Previously, we have proposed a framework based on the interdependence of perception and action, which allows us to explore athletic behavior in the more complex pacing situations occurring when athletes need to respond to actions of their opponents. In the present perspective we will further explore whether opponents, crucial external factors in competitive sports, could indeed be perceived as social invitations for action. Decisions regarding how to expend energy over the race are based on internal factors such as the physiological/biomechanical capacity of the athlete in relation to external factors such as those presented by opponents. For example: Is the athlete able to overtake competitors, or not? We present several experimental studies that demonstrate that athletes regulate their exercise intensity differently in head-to-head competition compared to time-trial exercises: Relational athlete-environment aspects seem to outweigh benefits of the individual optimal energy distribution. Also, the behavior of the opponents has been shown to influence pacing strategies of competing athletes, again demonstrating the importance of relational athlete-environment aspects in addition to strictly internal factors. An ecological perspective is presented in which opponents are proposed to present social affordances, and decision-making is conceptualized as a resultant of affordance-competition. This approach will provide novel insights in tactical decision-making and pacing behavior in head-to-head competitions. Future research should not only focus on the athlete's internal state, but also try to understand opponents in the context of the social affordances they provide.

  9. HEAD CIRCUMFERENCE REFERENCES FOR SCHOOL AGE CHILDREN IN WESTERN ROMANIA.

    Science.gov (United States)

    Chirita-Emandi, Adela; Doros, Gabriela; Simina, Iulia Jurca; Gafencu, Mihai; Puiu, Maria

    2015-01-01

    To provide head circumference references for school-aged children in western Romania, and compare them with references from other European countries. A total of 2742 children, aged 6-19 years, from Timis county, were examined by medical students, between February 2010-June 2011. Head circumference references were constructed by Cole's LMS method with LMSChartMaker software. The Romanian 3rd, 50th and 97th percentiles for head circumference were compared with recent references from Belgium and Germany. Generally, boys show significantly larger head circumference compared to girls at any age. The head circumference increments between 6 and 19 years are Romania to those from Germany and Belgium, we found lower median head circumference in Romanian boys and girls, that could be explained by a taller stature of boys and girls in Germany and Belgium compared to Romania.

  10. Operation of the AM-50 cutting head under different cutting conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Kusz, F; Fels, M

    1988-02-01

    Presents results of investigations into operation of the AM-50 heading machine. About 50% of headings, i.e. about 800 km/a, are driven by about 400 heading machines. It has been found that energy consumption depends on compression strength of rock and is 6 times higher for sandstone than for clayey shale. Power consumed by cutting heads depends mainly on the web used (30-150 mm depending on rock strength). Wear of cutting tools is 1-30 pieces per meter of heading advance at a working cross-section area of 15 m/sup 2/. The AM-50 machine uses cutting speeds of 1.1-3.5 m/s. Higher speeds negatively affect the resistance to cutting. Nonuniform tool wear on the cutting head circumference is an indication of improper head design that requires remedying.

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  13. Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques

    OpenAIRE

    MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an ...

  14. Muslim dress and the head-scarf debate

    NARCIS (Netherlands)

    Moors, A.; Skov, L.

    2010-01-01

    Debates about the presence of students wearing head scarves in public schools in West Europe started in the late 1980s; about a decade later, the employment of women wearing head scarves also became the focus of attention. These debates need to be seen within a context in which a new generation of

  15. Motion control of the Twente humanoid head

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Stramigioli, Stefano

    2009-01-01

    In this work, we present the design and the realization of the motion control algorithm implemented in the Twente hu- manoid head, a seven degrees of freedom (dof) robotic sys- tem. The aim of the project is to have a humanoid head that can serve as a research platform for human-machine interac-

  16. Thermal effects of dorsal head immersion in cold water on nonshivering humans.

    Science.gov (United States)

    Giesbrecht, Gordon G; Lockhart, Tamara L; Bristow, Gerald K; Steinman, Allan M

    2005-11-01

    Personal floatation devices maintain either a semirecumbent flotation posture with the head and upper chest out of the water or a horizontal flotation posture with the dorsal head and whole body immersed. The contribution of dorsal head and upper chest immersion to core cooling in cold water was isolated when the confounding effect of shivering heat production was inhibited with meperidine (Demerol, 2.5 mg/kg). Six male volunteers were immersed four times for up to 60 min, or until esophageal temperature = 34 degrees C. An insulated hoodless dry suit or two different personal floatation devices were used to create four conditions: 1) body insulated, head out; 2) body insulated, dorsal head immersed; 3) body exposed, head (and upper chest) out; and 4) body exposed, dorsal head (and upper chest) immersed. When the body was insulated, dorsal head immersion did not affect core cooling rate (1.1 degrees C/h) compared with head-out conditions (0.7 degrees C/h). When the body was exposed, however, the rate of core cooling increased by 40% from 3.6 degrees C/h with the head out to 5.0 degrees C/h with the dorsal head and upper chest immersed (P immersed (approximately 10%). The exaggerated core cooling during dorsal head immersion (40% increase) may result from the extra heat loss affecting a smaller thermal core due to intense thermal stimulation of the body and head and resultant peripheral vasoconstriction. Dorsal head and upper chest immersion in cold water increases the rate of core cooling and decreases potential survival time.

  17. Visual-auditory integration for visual search: a behavioral study in barn owls

    Directory of Open Access Journals (Sweden)

    Yael eHazan

    2015-02-01

    Full Text Available Barn owls are nocturnal predators that rely on both vision and hearing for survival. The optic tectum of barn owls, a midbrain structure involved in selective attention, has been used as a model for studying visual- auditory integration at the neuronal level. However, behavioral data on visual- auditory integration in barn owls are lacking. The goal of this study was to examine if the integration of visual and auditory signals contributes to the process of guiding attention towards salient stimuli. We attached miniature wireless video cameras on barn owls' heads (OwlCam to track their target of gaze. We first provide evidence that the area centralis (a retinal area with a maximal density of photoreceptors is used as a functional fovea in barn owls. Thus, by mapping the projection of the area centralis on the OwlCam's video frame, it is possible to extract the target of gaze. For the experiment, owls were positioned on a high perch and four food items were scattered in a large arena on the floor. In addition, a hidden loudspeaker was positioned in the arena. The positions of the food items and speaker were changed every session. Video sequences from the OwlCam were saved for offline analysis while the owls spontaneously scanned the room and the food items with abrupt gaze shifts (head saccades. From time to time during the experiment, a brief sound was emitted from the speaker. The fixation points immediately following the sounds were extracted and the distances between the gaze position and the nearest items and loudspeaker were measured. The head saccades were rarely towards the location of the sound source but to salient visual features in the room, such as the door knob or the food items. However, among the food items, the one closest to the loudspeaker had the highest probability of attracting a gaze shift. This result supports the notion that auditory signals are integrated with visual information for the selection of the next visual search

  18. Ophthalmic manifestations of head injury.

    Science.gov (United States)

    Kowal, L

    1992-02-01

    Head injuries are frequently associated with ophthalmic problems. The commonest problems seen in this series of 161 patients with head injury were problems with poor accommodation (16% of patients; 58% of these persisted), convergence (14% of patients; 35% of these persisted), pseudomyopia (19%; 55% persisted) and optic atrophy (26% of the patients; 78% of these were mild and easily missed on routine testing, and 22% were severe). Motility disorders were common, especially cranial nerve palsies. Other less frequent motility disturbances included apparent inferior oblique palsy, comitant esotropia, and exotropia which was often of the convergence insufficiency type.

  19. Head First 2D Geometry

    CERN Document Server

    Fallow), Stray

    2009-01-01

    Having trouble with geometry? Do Pi, The Pythagorean Theorem, and angle calculations just make your head spin? Relax. With Head First 2D Geometry, you'll master everything from triangles, quads and polygons to the time-saving secrets of similar and congruent angles -- and it'll be quick, painless, and fun. Through entertaining stories and practical examples from the world around you, this book takes you beyond boring problems. You'll actually use what you learn to make real-life decisions, like using angles and parallel lines to crack a mysterious CSI case. Put geometry to work for you, and

  20. "Female-Headed Families: Why Are They So Poor?"

    OpenAIRE

    Joan R. Rodgers

    1991-01-01

    Over the last few decades in the United States, the poverty rate for female-headed families (with no husband present) has been about three times the poverty rate for male-headed families (with no wife present) and about six times the poverty rate for married- couple families. This paper addresses the question of why, in general, female-headed families are so much poorer than other families. A decomposition of poverty rates and a set of probit models are used to identify the factors which dete...