  1. Will long acting insulin analogs influence the use of insulin pump therapy in type 1 diabetes?

    NARCIS (Netherlands)

    DeVries, J. Hans

    2005-01-01

    Insulin pump therapy enjoys a steadily growing number of users and is associated with an approximately 0.5% lower A1c as compared to flexible insulin injection therapy in type 1 diabetes patients. An important question is whether superiority of insulin pump therapy persists in the era of rapid

  2. An overview of insulin pump therapy: appropriate use of an ...

    African Journals Online (AJOL)

    2012-06-13

    Jun 13, 2012 ... Careful assessment of patients is vital, as pump therapy is an expensive treatment option and can be ... Intensive education of patients who meet the criteria is essential. .... to keep a food, blood glucose and insulin dose diary,.

  3. UK service level audit of insulin pump therapy in paediatrics.

    Science.gov (United States)

    Ghatak, A; Paul, P; Hawcutt, D B; White, H D; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Weston, P J

    2015-12-01

    To conduct an audit of insulin pump therapy in the UK after the issue of guidelines for the use of continuous subcutaneous insulin infusion by NICE in 2008 (Technology Appraisal 151). All centres in the UK, providing pump services to children and young people were invited to participate in an online audit. Audit metrics were aligned to NICE Technology Appraisal 151 and an electronic data collection tool was used. Of the 176 UK centres identified as providing pump services, 166 (94.3%) participated in the study. A total of 5094 children and young people were identified as using continuous subcutaneous insulin infusion (19% of all paediatric patients with Type 1 diabetes), with a median (range) of 16.9 (0.67-69.4)% per centre. Units had a median of 0.58 consultant sessions, 0.43 full-time equivalent diabetic specialist nurses, and 0.1 full-time equivalent dieticians delivering the pump service. The majority of this time was not formally funded. Families could access 24-h clinical and technical support (83% units), although the delivery varied between consultant, diabetic specialist nurse and company representatives. Only 53% of units ran, or accessed, structured education programmes for continuous subcutaneous insulin infusion use. Most units (86%) allowed continuous subcutaneous insulin infusion use for paediatric inpatients, but only 56% had written guidelines for this scenario. Nine percent of units had encountered funding refusal for a patient fulfilling NICE (Technology Appraisal 151) criteria. The number of children and young people on continuous subcutaneous insulin infusion therapy is consistent with numbers estimated by NICE. There is a worrying lack of funded healthcare professional time. The audit also identified gaps in the provision of structured education and absence of written inpatient guidelines. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  4. Management of insulin pump therapy in children with type 1 diabetes.

    Science.gov (United States)

    Abdullah, Nadeem; Pesterfield, Claire; Elleri, Daniela; Dunger, David B

    2014-12-01

    Insulin pump therapy is a current treatment option for children and adolescents with type 1 diabetes. Insulin pumps can provide a greater flexibility in insulin administration and meal planning, as compared with multiple insulin injections, and they may be particularly suitable for the paediatric age group. Many young people with diabetes have integrated insulin pumps into their daily practice. The use of insulin pumps can also be supplemented by the information retrieved from continuous glucose monitoring in the sensor-augmented pump therapy, which may improve glycaemic control. In this review, we describe the principles of pump therapy and summarise features of commercially available insulin pumps, with focus on practical management and the advantages and disadvantages of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. The SWITCH study (sensing with insulin pump therapy to control HbA(1c))

    DEFF Research Database (Denmark)

    Conget, Ignacio; Battelino, Tadej; Giménez, Marga

    2011-01-01

    studies investigating the effect of real-time continuous glucose monitoring (CGM) combined with pump therapy on glycemic outcomes in type 1 diabetes are increasing. Pump therapy is well established as a "gold standard" for insulin delivery, offering improvements over multiple daily insulin...

  6. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily inj...

  7. The role of insulin pump therapy for type 2 diabetes mellitus.

    Science.gov (United States)

    Landau, Zohar; Raz, Itamar; Wainstein, Julio; Bar-Dayan, Yosefa; Cahn, Avivit

    2017-01-01

    Many patients with type 2 diabetes fail to achieve adequate glucose control despite escalation of treatment and combinations of multiple therapies including insulin. Patients with long-standing type 2 diabetes often suffer from the combination of severe insulin deficiency in addition to insulin resistance, thereby requiring high doses of insulin delivered in multiple injections to attain adequate glycemic control. Insulin-pump therapy was first introduced in the 1970s as an approach to mimic physiological insulin delivery and attain normal glucose in patients with type 1 diabetes. The recent years have seen an increase in the use of this technology for patients with type 2 diabetes. This article summarizes the clinical studies evaluating insulin pump use in patients with type 2 diabetes and discusses the benefits and shortcomings of pump therapy in this population. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Insulin pump therapy in children with type 1 diabetes

    DEFF Research Database (Denmark)

    Szypowska, Agnieszka; Schwandt, Anke; Svensson, Jannet

    2016-01-01

    BACKGROUND: Intensified insulin delivery using multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) is recommended in children with type 1 diabetes (T1D) to achieve good metabolic control. OBJECTIVE: To examine the frequency of pump usage in T1D children treated...... in SWEET (Better control in Paediatric and Adolescent diabeteS: Working to crEate CEnTers of Reference) centers and to compare metabolic control between patients treated with CSII vs MDI. METHODS: This study included 16 570 T1D children participating in the SWEET prospective, multicenter, standardized...... is offered by most Sweet centers. The differences between centers affect the frequency of use of modern technology. Despite the heterogeneity of centers, T1D children achieve relatively good metabolic control, especially those treated with insulin pumps and those of younger age....

  9. A pilot study of factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy.

    Science.gov (United States)

    Wen, W; Frampton, R; Wright, K; Fattore, S; Shadbolt, B; Perampalam, S

    2016-02-01

    To identify the knowledge and management factors associated with glycaemic control among adults with Type 1 diabetes mellitus treated with insulin pump therapy. A cross-sectional study of adults with Type 1 diabetes mellitus on insulin pump therapy for at least 12 months (n = 50, 18-70 years old) was undertaken between December 2013 and May 2014. A new questionnaire was developed to evaluate participants' knowledge and management related to insulin pump therapy, and were correlated with insulin pump data, HbA1c and frequency of hypoglycaemia. Participants who changed their insulin pump settings when indicated had significantly better glycaemic control than those who did not (P = 0.04). Multivariate logistic regression analysis found that better overall insulin pump therapy management was a significant predictor of better glycaemic control (odds ratio 4.45, 95% confidence interval 1.61-12.3; P = 0.004) after adjusting for potential confounders including age, gender, duration of diabetes and insulin pump therapy. However, overall insulin pump therapy knowledge was not a significant predictor of glycaemic control (P = 0.058). There was no significant association between frequency of hypoglycaemia and insulin pump therapy knowledge or management. We identified some key knowledge and management factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy using a newly designed questionnaire. The pilot study assessed the clinical utility of this evaluation tool, which may facilitate provision of targeted education to insulin pump therapy users to achieve optimal glycaemic control. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  10. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy

    DEFF Research Database (Denmark)

    Battelino, T; Conget, I; Olsen, B

    2012-01-01

    The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes.......The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes....

  11. Association of Insulin Pump Therapy vs Insulin Injection Therapy With Severe Hypoglycemia, Ketoacidosis, and Glycemic Control Among Children, Adolescents, and Young Adults With Type 1 Diabetes.

    Science.gov (United States)

    Karges, Beate; Schwandt, Anke; Heidtmann, Bettina; Kordonouri, Olga; Binder, Elisabeth; Schierloh, Ulrike; Boettcher, Claudia; Kapellen, Thomas; Rosenbauer, Joachim; Holl, Reinhard W

    2017-10-10

    Insulin pump therapy may improve metabolic control in young patients with type 1 diabetes, but the association with short-term diabetes complications is unclear. To determine whether rates of severe hypoglycemia and diabetic ketoacidosis are lower with insulin pump therapy compared with insulin injection therapy in children, adolescents, and young adults with type 1 diabetes. Population-based cohort study conducted between January 2011 and December 2015 in 446 diabetes centers participating in the Diabetes Prospective Follow-up Initiative in Germany, Austria, and Luxembourg. Patients with type 1 diabetes younger than 20 years and diabetes duration of more than 1 year were identified. Propensity score matching and inverse probability of treatment weighting analyses with age, sex, diabetes duration, migration background (defined as place of birth outside of Germany or Austria), body mass index, and glycated hemoglobin as covariates were used to account for relevant confounders. Type 1 diabetes treated with insulin pump therapy or with multiple (≥4) daily insulin injections. Primary outcomes were rates of severe hypoglycemia and diabetic ketoacidosis during the most recent treatment year. Secondary outcomes included glycated hemoglobin levels, insulin dose, and body mass index. Of 30 579 patients (mean age, 14.1 years [SD, 4.0]; 53% male), 14 119 used pump therapy (median duration, 3.7 years) and 16 460 used insulin injections (median duration, 3.6 years). Patients using pump therapy (n = 9814) were matched with 9814 patients using injection therapy. Pump therapy, compared with injection therapy, was associated with lower rates of severe hypoglycemia (9.55 vs 13.97 per 100 patient-years; difference, -4.42 [95% CI, -6.15 to -2.69]; P young patients with type 1 diabetes, insulin pump therapy, compared with insulin injection therapy, was associated with lower risks of severe hypoglycemia and diabetic ketoacidosis and with better glycemic control during the

  12. Retinal characteristics during 1 year of insulin pump therapy in type 1 diabetes

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Hommel, Eva; Munch, Inger Christine

    2016-01-01

    of CSII led to an HbA1c reduction relative to continued MDI and a small increase in retinal thickness but not to early retinopathy worsening or to changes in retinal vascular, structural or functional characteristics. Longer duration of type 1 diabetes appears to be associated with lower macular venous......PURPOSE: To investigate changes in retinal metabolism, function, structure and morphology in relation to initiation of insulin pump therapy (continuous subcutaneous insulin infusion, CSII). METHODS: Visual acuity, retinopathy level, dark adaptation kinetics, retinal and subfoveal choroidal...... thickness, macular perfusion velocities, retinal vessel diameters and blood oxygen saturations were measured at baseline and after 1, 4, 16, 32 and 52 weeks in 31 patients with type 1 diabetes who started CSII and 20 patients who continued multiple daily insulin injections (MDI). RESULTS: One year of CSII...

  13. Use of case-based reasoning to enhance intensive management of patients on insulin pump therapy.

    Science.gov (United States)

    Schwartz, Frank L; Shubrook, Jay H; Marling, Cynthia R

    2008-07-01

    This study was conducted to develop case-based decision support software to improve glucose control in patients with type 1 diabetes mellitus (T1DM) on insulin pump therapy. While the benefits of good glucose control are well known, achieving and maintaining good glucose control remains a difficult task. Case-based decision support software may assist by recalling past problems in glucose control and their associated therapeutic adjustments. Twenty patients with T1DM on insulin pumps were enrolled in a 6-week study. Subjects performed self-glucose monitoring and provided daily logs via the Internet, tracking insulin dosages, work, sleep, exercise, meals, stress, illness, menstrual cycles, infusion set changes, pump problems, hypoglycemic episodes, and other events. Subjects wore a continuous glucose monitoring system at weeks 1, 3, and 6. Clinical data were interpreted by physicians, who explained the relationship between life events and observed glucose patterns as well as treatment rationales to knowledge engineers. Knowledge engineers built a prototypical system that contained cases of problems in glucose control together with their associated solutions. Twelve patients completed the study. Fifty cases of clinical problems and solutions were developed and stored in a case base. The prototypical system detected 12 distinct types of clinical problems. It displayed the stored problems that are most similar to the problems detected, and offered learned solutions as decision support to the physician. This software can screen large volumes of clinical data and glucose levels from patients with T1DM, identify clinical problems, and offer solutions. It has potential application in managing all forms of diabetes.

  14. Race, socioeconomic status, and treatment center are associated with insulin pump therapy in youth in the first year following diagnosis of type 1 diabetes

    Science.gov (United States)

    Increasing numbers of children and adolescents with type 1 diabetes (T1D) have been placed on insulin pump therapy. Nevertheless, data are limited regarding patterns of pump use during the first year of treatment and the clinical and socioeconomic factors associated with early use of pump therapy. T...

  15. Insulin pump therapy in children with diabetes mellitus: practice of Krasnoyarsk Krai

    Directory of Open Access Journals (Sweden)

    Tatiana Evgen'evna Taranushenko

    2012-12-01

    Full Text Available Aim. To summarize practical experience of insulin pump therapy (IPT in child population of Krasnoyarsk and to assess its efficacy for treatment of type 1 diabetes mellitus (T1DM in paediatrics. Materials and Methods. We performed a comparative analysis of clinical and laboratory data from 48 children with T1DM prior to and after 6-12 months of IPT. Results. IPT yielded fourfold decrease in complaints of hyperglycemia and labile glycemia without concurrent increase in reports of severe hypoglycemia.  We observed a trend for lowering of mean HbA1c levels, where 65% of patients showed positive dynamics in comparison with the period of multiple daily injection regimen. Interestingly, after 6-12 months of IPT, insulin requirement dropped in most patients. Conclusion. Our data support clinical efficiency and safety of IPT, as well as superiority of this treatment over multiple daily injection regimen. We conclude that IPT is a treatment of choice for children with T1DM.

  16. Routine sensor-augmented pump therapy in type 1 diabetes

    DEFF Research Database (Denmark)

    Nørgaard, Kirsten; Scaramuzza, Andrea; Bratina, Natasa

    2013-01-01

    Sensor-augmented pump (SAP) therapy can improve glycemic control, compared with multiple daily insulin injections or with insulin pump therapy alone, without increasing the risk of hypoglycemia.......Sensor-augmented pump (SAP) therapy can improve glycemic control, compared with multiple daily insulin injections or with insulin pump therapy alone, without increasing the risk of hypoglycemia....

  17. Fasting in Ramadan with an insulin pump.

    Science.gov (United States)

    Kesavadev, Jothydev

    2015-05-01

    A good majority of subjects with diabetes on insulin therapies observe fasting during Ramadan. The challenge for the physician and the patient is to manage diabetes without an interruption to fasting by avoiding hypoglycaemia and simultaneously ensuring that blood glucose remain at acceptable safe levels. Insulin Pumps differ from syringes and insulin pens in that it offers a variable basal rate, different type of boluses and associated calculators. The technological advances that pumps offer, help educated subjects pre-programme a reduced basal rate throughout the day. Pumps ensure avoidance of hypoglycaemia and hyperglycaemia and preserve quality of life and enhance confidence in patients during fasting. Due to multiple benefits, insulin pumps are considered the best delivery systems for insulin during the holy month of Ramadan, despite the prerequisites for its optimal output and cost concerns.

  18. Pitfalls of Insulin Pump Clocks

    Science.gov (United States)

    Reed, Amy J.

    2014-01-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713

  19. Efficacy of Insulin Pump Therapy on Diabetes Treatment Satisfaction and Glycemic Control Among Patients with Type 1 Diabetes Mellitus in Saudi Arabia: A Prospective Study

    OpenAIRE

    Al Hayek, Ayman A.; Robert, Asirvatham A.; Al Dawish, Mohamed A.; Braham, Rim B.; Goudeh, Hanouf S.; Al Sabaan, Fahad S.

    2015-01-01

    Introduction The aim of this study was to explore the impact of insulin pump therapy on diabetes treatment satisfaction and glycemic control among patients with type 1 diabetes mellitus (T1DM) in Saudi Arabia. Methods A 6-month, prospective study was conducted among 47 patients (aged 17?24?years) with T1DM who attended the Insulin Pump Clinic at Prince Sultan Military Medical City, Riyadh, Saudi Arabia, between April 2014 and November 2014. The respondents were purposively and conveniently se...

  20. Keeping Up with the Diabetes Technology: 2016 Endocrine Society Guidelines of Insulin Pump Therapy and Continuous Glucose Monitor Management of Diabetes.

    Science.gov (United States)

    Galderisi, Alfonso; Schlissel, Elise; Cengiz, Eda

    2017-09-23

    Decades after the invention of insulin pump, diabetes management has encountered a technology revolution with the introduction of continuous glucose monitoring, sensor-augmented insulin pump therapy and closed-loop/artificial pancreas systems. In this review, we discuss the significance of the 2016 Endocrine Society Guidelines for insulin pump therapy and continuous glucose monitoring and summarize findings from relevant diabetes technology studies that were conducted after the publication of the 2016 Endocrine Society Guidelines. The 2016 Endocrine Society Guidelines have been a great resource for clinicians managing diabetes in this new era of diabetes technology. There is good body of evidence indicating that using diabetes technology systems safely tightens glycemic control while managing both type 1 and type 2 diabetes. The first-generation diabetes technology systems will evolve as we gain more experience and collaboratively work to improve them with an ultimate goal of keeping people with diabetes complication and burden-free until the cure for diabetes becomes a reality.

  1. Changes in basal rates and bolus calculator settings in insulin pumps during pregnancy in women with type 1 diabetes

    DEFF Research Database (Denmark)

    Mathiesen, Jonathan M; Secher, Anna L; Ringholm, Lene

    2014-01-01

    OBJECTIVE: To explore insulin pump settings in a cohort of pregnant women with type 1 diabetes on insulin pump therapy with a bolus calculator. METHODS: Twenty-seven women with type 1 diabetes on insulin pump therapy were included in this study. At 8, 12, 21, 27 and 33 weeks, insulin pump setting...

  2. A review of the security of insulin pump infusion systems.

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  3. Valuing technology: A qualitative interview study with physicians about insulin pump therapy for children with type 1 diabetes.

    Science.gov (United States)

    Shulman, Rayzel; Miller, Fiona A; Daneman, Denis; Guttmann, Astrid

    2016-01-01

    Insulin pumps for children with type 1 diabetes have been broadly adopted despite equivocal evidence about comparative effectiveness. To understand why and inform policy related to public funding for new technologies, we explored how physicians interpret the value of pumps. We conducted open-ended, semi-structured interviews with 16 physicians from a pediatric diabetes network in Ontario, Canada, and analyzed the data using interpretive description. Respondents recognized that pumps fell short of expectations because they required hard work, as well as family and school support. Yet, pumps were valued for their status as new technologies and as a promising step in developing future technology. In addition, they were valued for their role within a therapeutic relationship, given the context of chronic childhood disease. These findings identify the types of beliefs that influence the adoption and diffusion of technologies. Some beliefs bear on hopes for new technology that may inappropriately hasten adoption, creating excess cost with little benefit. On the other hand, some beliefs identify potential benefits that are not captured in effectiveness studies, but may warrant consideration in resource allocation decisions. Still others suggest the need for remediation, such as those bearing on disparity in pump use by socioeconomic status. Understanding how technologies are valued can help stakeholders decide how to address such beliefs and expectations in funding decisions and implementation protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Depressive Symptoms, Emotion Dysregulation, and Bulimic Symptoms in Youth With Type 1 Diabetes: Varying Interactions at Diagnosis and During Transition to Insulin Pump Therapy.

    Science.gov (United States)

    Young-Hyman, Deborah L; Peterson, Claire M; Fischer, Sarah; Markowitz, Jessica T; Muir, Andrew B; Laffel, Lori M

    2016-07-01

    This study evaluated the associations between depressive symptoms, emotion dysregulation and bulimic symptoms in youth with type 1 diabetes (T1D) in the context of the diagnosis and treatment of T1D. Study participants were 103 youth in 2 distinct groups: newly diagnosed (New) or transitioning to pump therapy (continuous subcutaneous insulin infusion [CSII]; "Pump"), who completed questionnaires regarding symptoms of depression, emotion dysregulation, and bulimia. Glycemic control (A1c), height, weight, and questionnaires were evaluated within 10 days of diagnosis (n = 58) or at education/clinic visit before starting insulin utilizing CSII (n = 45). In the newly diagnosed group, only depression accounted for significant variance in bulimia scores (β = .47, P symptoms and emotion dysregulation were associated with greater bulimic symptoms. Depressive symptoms and emotion dysregulation, an indicator of poor coping/behavioral control, could help explain adoption of disordered eating behaviors in youth with T1D who are transitioning to pump therapy. © 2016 Diabetes Technology Society.

  5. Optimum bolus wizard settings in insulin pumps in children with Type 1 diabetes

    DEFF Research Database (Denmark)

    Andersen, A J B; Ostenfeld, A; Pipper, C B

    2016-01-01

    : Optimum insulin pump settings at pump initiation depend on both insulin requirements and use of the pump. Settings need to be individualized because the standardized calculation factors are not constant for children. There is a need to develop specific age- and insulin dose-dependent calculation factors.......AIM: To evaluate current insulin pump settings in an optimally regulated paediatric population using bolus wizard. METHODS: We used a retrospective study design to analyse data from 124 children on insulin pump therapy who had optimum HbA1c levels [

  6. Qualitative study into quality of life issues surrounding insulin pump use in type 1 diabetes

    DEFF Research Database (Denmark)

    Barnard, Katharine D.; Skinner, T. Chas

    2007-01-01

    Currently, there is a need for qualitative research about how insulin pump therapy changes quality of life, which is significant to people with type 1 diabetes. This study aimed to elicit thd experiences of current insulin pump users in order to discover the therapy's benefits, downsides and effe...

  7. Variability of Basal Rate Profiles in Insulin Pump Therapy and Association with Complications in Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Laimer, Markus; Melmer, Andreas; Mader, Julia K; Schütz-Fuhrmann, Ingrid; Engels, Heide-Rose; Götz, Gabriele; Pfeifer, Martin; Hermann, Julia M; Stettler, Christoph; Holl, Reinhard W

    2016-01-01

    Traditionally, basal rate profiles in continuous subcutaneous insulin infusion therapy are individually adapted to cover expected insulin requirements. However, whether this approach is indeed superior to a more constant BR profile has not been assessed so far. This study analysed the associations between variability of BR profiles and acute and chronic complications in adult type 1 diabetes mellitus. BR profiles of 3118 female and 2427 male patients from the "Diabetes-Patienten-Verlaufsdokumentation" registry from Germany and Austria were analysed. Acute and chronic complications were recorded 6 months prior and after the most recently documented basal rate. The "variability index" was calculated as variation of basal rate intervals in percent and describes the excursions of the basal rate intervals from the median basal rate. The variability Index correlated positively with severe hypoglycemia (r = .06; p1), hypoglycemic coma (r = .05; p = 0.002), and microalbuminuria (r = 0.05; p = 0.006). In addition, a higher variability index was associated with higher frequency of diabetic ketoacidosis (r = .04; p = 0.029) in male adult patients. Logistic regression analysis adjusted for age, gender, duration of disease and total basal insulin confirmed significant correlations of the variability index with severe hypoglycemia (β = 0.013; p1) and diabetic ketoacidosis (β = 0.012; p = 0.017). Basal rate profiles with higher variability are associated with an increased frequency of acute complications in adults with type 1 diabetes.

  8. Economic benefits of improved insulin stability in insulin pumps.

    Science.gov (United States)

    Weiss, Richard C; van Amerongen, Derek; Bazalo, Gary; Aagren, Mark; Bouchard, Jonathan R

    2011-05-01

    Insulin pump users discard unused medication and infusion sets according to labeling and manufacturer's instructions. The stability labeling for insulin aspart (rDNA origin] (Novolog) was increased from two days to six. The associated savings was modeled from the perspective of a hypothetical one-million member health plan and the total United States population. The discarded insulin volume and the number of infusion sets used under a two-day stability scenario versus six were modeled. A mix of insulin pumps of various reservoir capacities with a range of daily insulin dosages was used. Average daily insulin dose was 65 units ranging from 10 to 150 units. Costs of discarded insulin aspart [rDNA origin] were calculated using WAC (Average Wholesale Price minus 16.67%). The cost of pump supplies was computed for the two-day scenario assuming a complete infusion set change, including reservoirs, every two days. Under the six-day scenario complete infusion sets were discarded every six days while cannulas at the insertion site were changed midway between complete changes. AWP of least expensive supplies was used to compute their costs. For the hypothetical health plan (1,182 pump users) the annual reduction in discarded insulin volume between scenarios was 19.8 million units. The corresponding cost reduction for the plan due to drug and supply savings was $3.4 million. From the U.S. population perspective, savings of over $1 billion were estimated. Using insulin that is stable for six days in pump reservoirs can yield substantial savings to health plans and other payers, including patients.

  9. Use of telemedicine improves glycemic control and quality of life in type 1 diabetes children on insulin pump therapy

    Directory of Open Access Journals (Sweden)

    Dmitry N. Laptev

    2018-02-01

    Full Text Available Rationale: Healthcare access plays a significant role in the improvement and maintaining of glycemic control and quality of life in type 1 diabetes mellitus (T1DM patients on continuous subcutaneous insulin infusion (CSII. Aims: The aim of the study was to evaluate the feasibility of remote support in children and adolescents with type 1 diabetes mellitus (T1DM and its effect on glycemic control and quality of life. Materials and methods: In 40 children and adolescents (13±2,7 years, 18/22 m/f on CSII with inadequately controlled T1DM (HbA1c≥7,5% we evaluated the effectiveness of telemedical support (TS, as compared with conventional support (CS. Parameters of glycemic control (HbA1c, average glycemia, SD, etc. and quality of a life were obtained on follow-up visits. Patients and their parents in ТМ group twice a month sent their insulin pump data using to CSII center and diabetologists sent back their advice via e-mail, phone or Skype. The primary end point was the change from the baseline HbA1c level and the proportion of patients achieving HbA1c of less than 7.5%. Results: At 24 weeks, the baseline mean HbA1c (8.7% in the two study groups had decreased to 7.7% in the TS group, as compared with 8.4% in the CS group (P0,05. Conclusion: In children with inadequately controlled T1DM, telemedical support proved to be feasible and resulted in significant improvement in glucose control (HbA1c, glucose variability and quality of life without the increase in the incidence of DKA and severe glycemia.

  10. Bomba de infusão de insulina em diabetes melito tipo 1 Insulin pump therapy in type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Raphael Del Roio Liberatore Jr.

    2006-08-01

    ética.OBJECTIVE: To review the current experience with insulin pump therapy in children and adolescents in order to guide pediatricians regarding indications and complications. SOURCES OF DATA : Systematic review of articles published in the literature referring to the use of insulin pump therapy, indications, complications and response to treatment. All articles published between 1995 and 2005 and appearing in the MEDLINE and LILACS databases were reviewed. The keywords were: insulin pump, type 1 diabetes mellitus and diabetes mellitus. The articles covering the subject of interest and referring to children and adolescents were selected. SUMMARY OF THE FINDINGS : Insulin pump therapy is not required for all patients with type 1 diabetes, since intensive treatments produce very similar results in terms of glycated hemoglobin and control of complications over the medium and long terms. However, the pump allows for greater comfort for patients, with less rigid meal schedules and better quality of life. The first requirement for patients intending to use the pump is getting used to having a device attached to the body and following strict glucose control; otherwise, pump therapy is not advantageous. Complications are rare due to the technologies currently available. The cost, however, is greater than with conventional treatments. CONCLUSION: The development of infusion pumps and glucose monitors, including continuous monitoring systems, will lead to "intelligent pumps," so that a true "artificial pancreas" will be available, which can even be implanted in the patient, allowing non-diabetic persons to lead a normal life.

  11. Cost-Effectiveness of Sensor-Augmented Pump Therapy with Low Glucose Suspend Versus Standard Insulin Pump Therapy in Two Different Patient Populations with Type 1 Diabetes in France.

    Science.gov (United States)

    Roze, Stéphane; Smith-Palmer, Jayne; Valentine, William; Payet, Vincent; de Portu, Simona; Papo, Natalie; Cucherat, Michel; Hanaire, Helene

    2016-02-01

    Sensor-augmented pump therapy (SAP) provides a useful adjunct relative to continuous subcutaneous insulin infusion (CSII) alone. It can provide early warning of the onset of hyperglycemia and hypoglycemia and has the functionality to suspend insulin delivery if sensor glucose levels fall below a predefined threshold. The aim was to assess the cost-effectiveness of SAP with low glucose suspend (LGS) versus CSII alone in type 1 diabetes. Cost-effectiveness analysis was performed using the CORE Diabetes Model, using published clinical input data. The analysis was performed in two cohorts: one with uncontrolled glycated hemoglobin at baseline and one at elevated risk for hypoglycemic events. The analysis was conducted from a healthcare payer perspective over a lifetime time horizon; future costs and clinical outcomes were discounted at 4% per annum. In patients with uncontrolled glycated hemoglobin at baseline, SAP + LGS resulted in improved discounted quality-adjusted life expectancy (QALE) versus CSII (10.55 quality-adjusted life-years [QALYs] vs. 9.36 QALYs) but higher mean lifetime direct costs (€84,972 vs. €49,171) resulting in an incremental cost-effectiveness ratio (ICER) of €30,163 per QALY gained. In patients at elevated risk for hypoglycemia, the ICER was €22,005 per QALY gained for SAP + LGS versus CSII as lifetime costs were higher (€88,680 vs. €57,097), but QALE was also higher (18.46 QALYs vs. 18.30 QALYs). In France, projected improvements in outcomes with SAP + LGS versus CSII translated into an ICER generally considered as good value for money, particularly in patients who experience frequent and/or problematic hypoglycemic events.

  12. Feeding problems reported by parents of young children with type 1 diabetes on insulin pump therapy and their associations with children's glycemic control.

    Science.gov (United States)

    Patton, Susana R; Williams, Laura B; Dolan, Lawrence M; Chen, Ming; Powers, Scott W

    2009-11-01

    Previous research demonstrated high rates of perceived mealtime behavior problems in families of young children with type 1 diabetes who were managed with conventional therapy. Because of new insulin regimens that offer greater flexibility, reexamination of mealtime behaviors is required. We assessed parent-reported mealtime behaviors in a sample of young children using an insulin pump. An additional aim was to evaluate the associations of two measures of parental feeding behavior with children's glycemic control. Primary caregivers of 31 young children (mean age = 5.0 +/- 1.3 yr) completed the Child Feeding Questionnaire (CFQ) and the Behavioral Pediatric Feeding Assessment Scale (BPFAS). Hemoglobin A1c (HbA1c) was used as a surrogate marker for children's glycemic control. Children had a mean HbA1c of 7.8 +/- 0.64%. Mean CFQ - Restriction and Pressure to Eat scores were 3.1 +/- 0.94 and 2.0 +/- 0.88, respectively (range = 1-5). Mean BPFAS - Parent and Child scores were 16.0 +/- 4.3 (range = 10-50) and 44.9 +/- 9.3 (range = 25-125), respectively. Positive correlations were found between children's HbA1c levels and caregivers' reporting of frequency of child mealtime behavior problems. Caregivers of young children on pump therapy report relatively low rates of mealtime behavior problems. However, correlations with children's HbA1c suggest that parent-child mealtime behaviors continue to relate to children's health outcomes. Research is needed to determine if changing mealtime interactions can improve children's glycemic control; items from the BPFAS and CFQ can offer targets to guide interventions.

  13. Using Remote Communication Technology in Insulin Pump Training: A Feasibility Study.

    Science.gov (United States)

    Parks, Linda; Kim, Tae Youn

    2015-09-29

    This feasibility study was designed to examine if remote communication technology can be used in the technical training of an insulin pump in adults with diabetes who were familiar with insulin pump therapy. Surveys were emailed to 69 individuals who purchased an insulin pump and had been trained by the manufacturer's diabetes educators. In consultation with providers, participants were given the choice of receiving training in a face-to-face meeting or via remote communication technology. The survey consisted of 27 questions asking participants' characteristics, device proficiency, confidence, and their satisfaction with the insulin pump and the training method. Differences between the 2 groups were examined using bivariate analyses. There were 17 participants in the remote group and 20 participants in the face-to-face group. Participants had a mean age of 40.9 ± 14.3 years, had diabetes for 24.3 ± 13.8 years, and used an insulin pump for 9.8 ± 4.9 years. The participants in both groups were not statistically different in age, diabetes history, years on insulin pump, device proficiency, confidence, or satisfaction with the training method. The remote group reported less graduate-level education (P remote communication technology may be an effective tool to provide technical training to adults who are familiar with insulin pump therapy. Additional research is required to determine the effectiveness of the remote insulin pump training. © 2015 Diabetes Technology Society.

  14. Insulin Pump Malfunction During Hospitalization: Two Case Reports.

    Science.gov (United States)

    Faulds, Eileen R; Wyne, Kathleen L; Buschur, Elizabeth O; McDaniel, Jodi; Dungan, Kathleen

    2016-06-01

    Insulin pump malfunctions and failures continue to occur; however, more severe malfunctions such as the "runaway pump" phenomenon are rarely reported. This article describes two cases of pump malfunction in which pump users appear to have received an unsolicited bolus of insulin resulting in severe episodes of hypoglycemia during hospitalization. Both cases of insulin pump malfunction occurred in the inpatient setting at a large academic medical center in the United States. An analysis of the corresponding insulin pump downloads was performed. The Food and Drug Administration's (FDA's) Manufacturer and User Facility Device Experience (MAUDE) database was searched for similar cases involving Medtronic (Northridge, CA) insulin pumps using the terms "pump," "infusion," "insulin AND malfunction AND Medtronic." The two cases described show remarkable similarities, each demonstrating a severe hypoglycemic event preceded by an infusion site change followed by an alarm. In both cases a rapid spraying of insulin was reported. The insulin pump downloads validated much of the patients' and medical staff's descriptions of events. The FDA's MAUDE database search revealed 425 cases meeting our search term criteria. All cases were reviewed. Seven cases were identified involving independent movement of the reservoir piston. The cases detailed are the first to describe an insulin pump malfunction of this nature in the hospital setting involving unsolicited insulin boluses leading to severe hypoglycemia. The cases are particularly compelling in that they were witnessed by medical personnel. Providers and patients should receive instruction education on the recognition and management of insulin pump malfunction.

  15. Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study.

    Science.gov (United States)

    Bally, Lia; Thabit, Hood; Kojzar, Harald; Mader, Julia K; Qerimi-Hyseni, Jehona; Hartnell, Sara; Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Pieber, Thomas R; Evans, Mark L; Hovorka, Roman

    2017-04-01

    Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA 1c below 7·5% (58 mmol/mol). In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA 1c below 7·5% from Addenbrooke's Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2-4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2-4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9-10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT02727231, and is completed. Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. One participant withdrew during the first closed-loop period because of dissatisfaction with study devices and glucose control. The proportion of time when sensor glucose concentration was in target range was 10·5 percentage points higher (95% CI 7·6-13·4; pday-and-night hybrid closed-loop insulin delivery under unsupervised, free-living conditions for 4 weeks in adults with type 1 diabetes and HbA 1c below 7·5% is safe and well tolerated, improves glucose control, and reduces hypoglycaemia burden. Larger and longer studies

  16. Generic Safety Requirements for Developing Safe Insulin Pump Software

    Science.gov (United States)

    Zhang, Yi; Jetley, Raoul; Jones, Paul L; Ray, Arnab

    2011-01-01

    Background The authors previously introduced a highly abstract generic insulin infusion pump (GIIP) model that identified common features and hazards shared by most insulin pumps on the market. The aim of this article is to extend our previous work on the GIIP model by articulating safety requirements that address the identified GIIP hazards. These safety requirements can be validated by manufacturers, and may ultimately serve as a safety reference for insulin pump software. Together, these two publications can serve as a basis for discussing insulin pump safety in the diabetes community. Methods In our previous work, we established a generic insulin pump architecture that abstracts functions common to many insulin pumps currently on the market and near-future pump designs. We then carried out a preliminary hazard analysis based on this architecture that included consultations with many domain experts. Further consultation with domain experts resulted in the safety requirements used in the modeling work presented in this article. Results Generic safety requirements for the GIIP model are presented, as appropriate, in parameterized format to accommodate clinical practices or specific insulin pump criteria important to safe device performance. Conclusions We believe that there is considerable value in having the diabetes, academic, and manufacturing communities consider and discuss these generic safety requirements. We hope that the communities will extend and revise them, make them more representative and comprehensive, experiment with them, and use them as a means for assessing the safety of insulin pump software designs. One potential use of these requirements is to integrate them into model-based engineering (MBE) software development methods. We believe, based on our experiences, that implementing safety requirements using MBE methods holds promise in reducing design/implementation flaws in insulin pump development and evolutionary processes, therefore improving

  17. Effect of insulin pump infusion on comprehensive stress state of ...

    African Journals Online (AJOL)

    Effect of insulin pump infusion on comprehensive stress state of patients with diabetic ketoacidosis. ... Relevant diabetes-associated serum indices, oxidative stress and stress hormone levels were compared between the ... from 32 Countries:.

  18. [The use of continuous subcutaneous insulin infusion (CSII) with personal insulin pumps in the treatment of children and adolescents with diabetes type 1].

    Science.gov (United States)

    Jarosz-Chobot, Przemysława

    2004-01-01

    This paper sums up recently published researches on the continuous subcutaneous insulin infusion (CSII) with the use of insulin pump in children and adolescents with diabetes type 1. Obtaining a balance in the organism metabolism in childhood and adolescence diabetology is nowadays one of the most important rules of the diabetes management in children. One of the modern ways to achieve that goal is the intensive insulin therapy model with use of the insulin pump. In this paper the advantages and disadvantages as well as the indications and contraindications for the CSII in children and adolescents with diabetes are widely discussed.

  19. Continuous subcutaneous insulin infusion therapy for Type 1 diabetes mellitus in children.

    Science.gov (United States)

    Mavinkurve, M; Quinn, A; O'Gorman, C S

    2016-05-01

    Continuous subcutaneous insulin pump therapy (CSII or pump therapy) is a well-recognised treatment option for Type 1 diabetes mellitus (T1DM) in paediatrics. It is especially suited to children because it optimises control by improving flexibility across age-specific lifestyles. The NICE guidelines (2008) recognise that pump therapy is advantageous and that it should be utilised to deliver best practice. In Ireland, the National Clinical Program for Diabetes will increase the availability and uptake of CSII in children and thus more clinicians are likely to encounter children using CSII therapy. This is a narrative review which discusses the basic principles of pump therapy and focuses on aspects of practical management. Insulin pump management involves some basic yet important principles which optimise the care of diabetes in children. This review addresses the principles of insulin pump management in children which all health care professionals involved in caring for the child with diabetes, shoud be familiar with.

  20. Insulin pumps and insulin quality--requirements and problems.

    Science.gov (United States)

    Brange, J; Havelund, S

    1983-01-01

    In developing insulin solution suitable for delivery devices the chemical and biological stability, as well as the physical stability, must be taken into consideration. Addition of certain mono- and disaccharides increases the physical stability of neutral insulin solutions, but concurrently the chemical and biological stability decrease to an unacceptable degree. Addition of Ca-ions in low concentrations offers a physiologically acceptable method for stabilizing neutral insulin solutions against heat precipitation without affecting the quality, including the chemical and biological stability.

  1. Insulin Pump and CGM Usage in the United States and Germany

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Weber, Dietmar; Faber-Heinemann, Gabriele; Heinemann, Lutz

    2015-01-01

    Background: This survey collected and evaluated user responses about routine tasks and preferences regarding insulin pumps and infusion sets (IIS) with comparison of intercountry differences between the United States (US) and Germany (GER), chosen for their large insulin pump populations. Methods: A total of 985 subjects (534 US, 451 GER; 60% female) with type 1 diabetes on pump therapy anonymously answered 20 pump-related questions. US subjects also answered 11 questions about continuous glucose monitoring (CGM) usage. Results: Length of use of insulin cartridges is shorter in US than in GER, mean (SD) 4.3 (5.0) versus 5.3 (3.2) days (P 3 days vs 7.7% for <3 days; P < .01), and with use of an auto-insertion device (vs manual IIS insertion) in the US (7.2% vs 6.9%), but not in GER (7.7% vs 7.9%). Only 47% of pump wearers stated that they were “very satisfied” with their pump (49% US vs 45% GER, ns). However, 98% would recommend the pump to others (95% vs 93%, ns). Analysis of CGM questions showed that 297 (60%) of 496 US responders currently wore one. Of these, 84% said they would recommend CGM to others. CGM wearers who stated they were “very satisfied” with their CGM had lower HbA1c than those who said they were “partly satisfied” (6.9% vs 7.2%). Conclusions: This survey shows interesting differences in real-world use of insulin pumps in 2 large markets, and suggests areas where insulin pumps and CGMs might be improved. PMID:26071425

  2. Model-based sensor-augmented pump therapy.

    Science.gov (United States)

    Grosman, Benyamin; Voskanyan, Gayane; Loutseiko, Mikhail; Roy, Anirban; Mehta, Aloke; Kurtz, Natalie; Parikh, Neha; Kaufman, Francine R; Mastrototaro, John J; Keenan, Barry

    2013-03-01

    In insulin pump therapy, optimization of bolus and basal insulin dose settings is a challenge. We introduce a new algorithm that provides individualized basal rates and new carbohydrate ratio and correction factor recommendations. The algorithm utilizes a mathematical model of blood glucose (BG) as a function of carbohydrate intake and delivered insulin, which includes individualized parameters derived from sensor BG and insulin delivery data downloaded from a patient's pump. A mathematical model of BG as a function of carbohydrate intake and delivered insulin was developed. The model includes fixed parameters and several individualized parameters derived from the subject's BG measurements and pump data. Performance of the new algorithm was assessed using n = 4 diabetic canine experiments over a 32 h duration. In addition, 10 in silico adults from the University of Virginia/Padova type 1 diabetes mellitus metabolic simulator were tested. The percentage of time in glucose range 80-180 mg/dl was 86%, 85%, 61%, and 30% using model-based therapy and [78%, 100%] (brackets denote multiple experiments conducted under the same therapy and animal model), [75%, 67%], 47%, and 86% for the control experiments for dogs 1 to 4, respectively. The BG measurements obtained in the simulation using our individualized algorithm were in 61-231 mg/dl min-max envelope, whereas use of the simulator's default treatment resulted in BG measurements 90-210 mg/dl min-max envelope. The study results demonstrate the potential of this method, which could serve as a platform for improving, facilitating, and standardizing insulin pump therapy based on a single download of data. © 2013 Diabetes Technology Society.

  3. One-year efficacy and safety of Web-based follow-up using cellular phone in type 1 diabetic patients under insulin pump therapy: the PumpNet study.

    Science.gov (United States)

    Benhamou, P-Y; Melki, V; Boizel, R; Perreal, F; Quesada, J-L; Bessieres-Lacombe, S; Bosson, J-L; Halimi, S; Hanaire, H

    2007-06-01

    Conventional follow-up of type 1 diabetic patients treated with continuous subcutaneous insulin infusion (CSII) was compared with intensive coaching using the Web and the cellular phone network for retrospective data transmission and short message service (SMS). Thirty poorly controlled patients (HbA1c 7.5-10%) were enrolled in a bicenter, open-label, randomized, 12-month, two-period, crossover study. After a 1-month run-in period, 15 patients were randomly assigned to receive weekly medical support through SMS based upon weekly review of glucose values, while 15 patients continued to download self-monitored blood glucose (SMBG) values on a weekly basis without receiving SMS. After 6 months, patients crossed over to the alternate sequence for 6 additional months. Visits at the clinic were maintained every 3 months. Patients with long-standing inadequately controlled diabetes (24 +/- 13 years) were included. A non-significant trend to reduction in HbA(1c) (-0.25+/-0.94%, Psafety issue (hypoglycemia, glucose variability) was reported. Adherence to SMBG was not affected by the trial. Quality of life analysis suggests a significant improvement in DQOL global score, as well as the DQOL satisfaction with life subscale, during the SMS sequence. Long-term telemedical follow-up of insulin pump-treated patients using a cellular phone-, SMS- and Web-based platform is feasible, safe, does not alter quality of life and associated with a trend toward improved metabolic control.

  4. Intranasal insulin therapy: the clinical realities

    DEFF Research Database (Denmark)

    Hilsted, J; Madsbad, Sten; Hvidberg, A

    1995-01-01

    To evaluate metabolic control and safety parameters (hypoglycaemia frequency and nasal mucosa physiology), 31 insulin-dependent diabetic patients were treated with intranasal insulin at mealtimes for 1 month and with subcutaneous fast-acting insulin at meals for another month in an open, crossover...... randomized trial. During both treatment periods the patients were treated with intermediate-acting insulin at bedtime. Six of the patients were withdrawn from the study during intranasal insulin therapy due to metabolic dysregulation. Serum insulin concentrations increased more rapidly and decreased more...... quickly during intranasal as compared with subcutaneous insulin administration. Metabolic control deteriorated, as assessed by haemoglobin A1c concentrations, slightly but significantly after intranasal as compared with subcutaneous insulin therapy. The bioavailability of intranasally applied insulin...

  5. Evaluation of current trends and recent development in insulin therapy for management of diabetes mellitus.

    Science.gov (United States)

    Nawaz, Muhammad Sarfraz; Shah, Kifayat Ullah; Khan, Tahir Mehmood; Rehman, Asim Ur; Rashid, Haroon Ur; Mahmood, Sajid; Khan, Shahzeb; Farrukh, Muhammad Junaid

    2017-12-01

    Diabetes mellitus is a major health problem in developing countries. There are various insulin therapies to manage diabetes mellitus. This systematic review evaluates various insulin therapies for management of diabetes mellitus worldwide. This review also focuses on recent developments being explored for better management of diabetes mellitus. We reviewed a number of published articles from 2002 to 2016 to find out the appropriate management of diabetes mellitus. The paramount parameters of the selected studies include the insulin type & its dose, type of diabetes, duration and comparison of different insulin protocols. In addition, various newly developed approaches for insulin delivery with potential output have also been evaluated. A great variability was observed in managing diabetes mellitus through insulin therapy and the important controlling factors found for this therapy include; dose titration, duration of insulin use, type of insulin used and combination therapy of different insulin. A range of research articles on current trends and recent advances in insulin has been summarized, which led us to the conclusion that multiple daily insulin injections or continuous subcutaneous insulin infusion (insulin pump) is the best method to manage diabetes mellitus. In future perspectives, development of the oral and inhalant insulin would be a tremendous breakthrough in Insulin therapy. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  6. Comparative Dose Accuracy of Durable and Patch Insulin Infusion Pumps

    Science.gov (United States)

    Jahn, Luis G.; Capurro, Jorge J.; Levy, Brian L.

    2013-01-01

    Background: As all major insulin pump manufacturers comply with the international infusion pump standard EN 60601-2-24:1998, there may be a general assumption that all pumps are equal in insulin-delivery accuracy. This research investigates single-dose and averaged-dose accuracy of incremental basal deliveries for one patch model and three durable models of insulin pumps. Method: For each pump model, discrete single doses delivered during 0.5 U/h basal rate infusion over a 20 h period were measured using a time-stamped microgravimetric system. Dose accuracy was analyzed by comparing single doses and time-averaged doses to specific accuracy thresholds (±5% to ±30%). Results: The percentage of single doses delivered outside accuracy thresholds of ±5%, ±10%, and ±20% were as follows: Animas OneTouch® Ping® (43.2%, 14.3%, and 1.8%, respectively), Roche Accu-Chek® Combo (50.6%, 24.4%, and 5.5%), Medtronic Paradigm® RevelTM/VeoTM (54.2%, 26.7%, and 6.6%), and Insulet OmniPod® (79.1%, 60.5%, and 34.9%). For 30 min, 1 h, and 2 h averaging windows, the percentage of doses delivered outside a ±15% accuracy were as follows: OneTouch Ping (1.0%, 0.4%, and 0%, respectively), Accu-Chek Combo (4.2%, 3.5%, and 3.1%), Paradigm Revel/Veo (3.9%, 3.1%, and 2.2%), and OmniPod (33.9%, 19.9%, and 10.3%). Conclusions: This technical evaluation demonstrates significant differences in single-dose and averaged-dose accuracy among the insulin pumps tested. Differences in dose accuracy were most evident between the patch pump model and the group of durable pump models. Of the pumps studied, the Animas OneTouch Ping demonstrated the best single-dose and averaged-dose accuracy. Further research on the clinical relevance of these findings is warranted. PMID:23911184

  7. Influence of health locus of control and fear of hypoglycaemia on glycaemic control and treatment satisfaction in people with Type 1 diabetes on insulin pump therapy.

    Science.gov (United States)

    Indelicato, L; Mariano, V; Galasso, S; Boscari, F; Cipponeri, E; Negri, C; Frigo, A; Avogaro, A; Bonora, E; Trombetta, M; Bruttomesso, D

    2017-05-01

    To assess the influence of health locus of control and fear of hypoglycaemia on metabolic control and treatment satisfaction in people with Type 1 diabetes mellitus on continuous subcutaneous insulin infusion. People with Type 1 diabetes on continuous subcutaneous insulin infusion for at least 1 year, sub-classified as an 'acceptable glucose control' group [HbA 1c ≤ 58 mmol/mol (7.5%)] and a 'suboptimum glucose control' group [HbA 1c > 58 mmol/mol (7.5%)], were consecutively enrolled in a multicentre cross-sectional study. Questionnaires were administered to assess health locus of control [Multidimensional Health Locus of Control (MHLC) scale, with internal and external subscales], fear of hypoglycaemia [Hypoglycaemia Fear Survey II (HFS-II)] and treatment satisfaction [Diabetes Treatment Satisfaction Questionnaire (DTSQ)]. We enrolled 214 participants (mean ± sd age 43.4 ± 12.1 years). The suboptimum glucose control group (n = 127) had lower mean ± sd internal MHLC and DTSQ scores than the acceptable glucose control group (19.6 ± 5.2 vs 21.0 ± 5.0, P = 0.04 and 28.8 ± 4.8 vs 30.9 ± 4.5, P locus represents the most important locus of control pattern for achieving good metabolic control. © 2017 Diabetes UK.

  8. Comparison of rechargeable versus battery-operated insulin pumps: temperature fluctuations.

    Science.gov (United States)

    Vereshchetin, Paul; McCann, Thomas W; Ojha, Navdeep; Venugopalan, Ramakrishna; Levy, Brian L

    2016-01-01

    The role of continuous subcutaneous insulin infusion (insulin pumps) has become increasingly important in diabetes management, and many different types of these systems are currently available. This exploratory study focused on the reported heating issues that lithium-ion battery-powered pumps may have during charging compared with battery-operated pumps. It was found that pump temperature increased by 6.4°C during a long charging cycle of a lithiumion battery-operated pump under ambient temperatures. In an environmental-chamber kept at 35°C, the pump temperature increased by 4.4°C, which indicates that the pump temperature was above that of the recommended safety limit for insulin storage of 37°C. When designing new pumps, and when using currently available rechargeable pumps in warmer climates, the implications of these temperature increases should be taken into consideration. Future studies should also further examine insulin quality after charging.

  9. Comparison of different insulin pump makes under routine care conditions in adults with Type 1 diabetes.

    Science.gov (United States)

    Leelarathna, L; Roberts, S A; Hindle, A; Markakis, K; Alam, T; Chapman, A; Morris, J; Urwin, A; Jinadev, P; Rutter, M K

    2017-10-01

    To compare long-term HbA 1c changes associated with different insulin pumps during routine care in a large cohort of adults with Type 1 diabetes representative of other clinic populations. Observational, retrospective study of 508 individuals starting pump therapy between 1999 and 2014 (mean age, 40 years; 55% women; diabetes duration, 20 years; 94% Type 1 diabetes; median follow-up, 3.7 years). Mixed linear models compared covariate-adjusted HbA 1c changes associated with different pump makes. The pumps compared were: 50% Medtronic, 24% Omnipod, 14% Roche and 12% Animas. Overall HbA 1c levels improved and improvements were maintained during a follow-up extending to 10 years (HbA 1c : pre-continuous subcutaneous insulin infusion (pre-CSII) vs. 12 months post CSII, 71 (61, 82) vs. 66 (56, 74) mmol/mol; 8.7 (7.7, 9.6) vs. 8.2 (7.3, 8.9)%; P < 0.0001). The percentage of individuals with HbA 1c ≥ 64 mmol/mol (8.0%) reduced from a pre-CSII level of 68% to 55%. After adjusting for baseline confounders, there were no between-pump differences in HbA 1c lowering (P = 0.44), including a comparison of patch pumps with traditional catheter pumps (P = 0.63). There were no significant (P < 0.05) between-pump differences in HbA 1c lowering in pre-specified subgroups stratified by pre-pump HbA 1c , age or diabetes duration. HbA 1c lowering was positively related to baseline HbA 1c (P < 0.001) and diabetes duration (P = 0.017), and negatively related to the number of years of CSII use (P = 0.024). Under routine care conditions, there were no covariate-adjusted differences in HbA 1c lowering when comparing different pump makes, including a comparison of patch pumps vs. traditional catheter pumps. Therefore, the choice of CSII make should not be influenced by the desired degree of HbA 1c lowering. © 2017 Diabetes UK.

  10. A sophisticated programmable miniaturised pump for insulin delivery.

    Science.gov (United States)

    Klein, J C; Slama, G

    1980-09-01

    We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.

  11. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  12. Insulin appearance of subcutaneously infused insulin: influence of the basal rate pulse interval of the infusion pump.

    Science.gov (United States)

    Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J

    1985-05-01

    To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.

  13. Insulin regulation of Na/K pump activity in rat hepatoma cells

    International Nuclear Information System (INIS)

    Gelehrter, T.D.; Shreve, P.D.; Dilworth, V.M.

    1984-01-01

    Insulin rapidly increases Na/K pump activity in HTC rat hepatoma cells in tissue culture, as measured by the ouabain-sensitive influx of the potassium analogue 86Rb+. Increased influx is observed within minutes and is maximal (70% above control) within 1-2 h. The effect appears to be mediated by the insulin receptors, as: the concentration dependence on insulin is identical to that for insulin induction of tyrosine aminotransferase and stimulation of 2-aminoisobutyric acid transport, proinsulin is 6% as potent as insulin, and the effect is blocked by anti-receptor antibodies. The early stimulation of potassium influx is not blocked by cycloheximide and is not associated with an increased number of pump sites as measured by 3 H-ouabain binding. The insulin effect is blocked by amiloride, which blocks sodium influx, and is mimicked by the sodium ionophore monensin, which increases sodium influx and intracellular accumulation. Insulin also rapidly increases the initial rate of 22 Na+ influx, suggesting that insulin may enhance Na/K pump activity, in part, by increasing intracellular sodium concentration. Incubation of HTC cells with insulin for 24 h causes complete unresponsiveness to the insulin induction of transaminase and stimulation of amino acid transport, a phenomenon mediated by postbinding mechanisms. In contrast, similar incubation with insulin does not cause unresponsiveness to the insulin stimulation of Na/K pump activity. Therefore, the site of regulation of responsiveness to insulin must be distal to, or separate from, those events causing stimulation of ion fluxes

  14. Analysis of insulin pump settings in children and adolescents with type 1 diabetes mellitus.

    Science.gov (United States)

    Lau, Yu Ning; Korula, Sophy; Chan, Albert K; Heels, Kristine; Krass, Ines; Ambler, Geoffrey

    2016-08-01

    To characterize current insulin pump settings used in young patients with type 1 diabetes mellitus (T1DM) and to assess their relationship to glycemic control. This retrospective study included patients aged 18 yr old with T1DM >1 yr using a Medtronic pump device. Pump data including number of blood glucose (BG) tests per day, basal and bolus insulin parameters, carbohydrate ratio (CR), and insulin sensitivity factors (ISFs) were averaged over 14 d for statistical analyses. Anthropometric data and recent glycosylated hemoglobin A1c (HbA1c) were recorded. A total of 292 patients (144 males and 148 females) were included in the study. Participants had a median age (interquartile range, IQR) of 12.9 yr (10.0-15.1 yr) and pump duration of 2.8 yr (1.5-4.2 yr). No significant differences in median HbA1c (IQR) were observed in preschool [n = 14; HbA1c 7.8% (7.3-8.3%)], prepubertal [n = 105; HbA1c 8.1% (7.7-8.9%)], and adolescent subjects [n = 173; HbA1c 8.4% (7.7-9.0%)]. Adolescents took significantly fewer boluses and BG tests per day compared with younger children (p insulin delivery was noted. Additionally, stronger carbohydrate cover and weaker corrections were used in real-life compared with theoretical 500 and 100 rules, respectively. Lower HbA1c was associated with higher number of daily boluses, greater number of BG tests per day, lower average CR/500 rule ratio, and higher average ISF/100 rule ratio adjusted for age (R(2) = 0.22; p 1). Insulin pump therapy requires continuous adjustments and glycemic targets are achieved by a minority. We believe this is the first study in pediatric cohort looking at association between CR and ISF with glycemic control. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. The automatic regulation of the basal dose on the insulin pump for the treatment of patients that have Diabetes type 1.

    Science.gov (United States)

    Mehanović, Sifet; Mujić, Midhat

    2010-05-01

    Diabetes mellitus type 1 is a chronic metabolic disorder, and its main characteristic is Hyperglycemia. It usually occurs in the early years because of the absolute or relative absence of the active insulin that is caused by the autoimmune disease of the beta cells of the pancreas. Despite the numerous researches and efforts of the scientists, the therapy for Diabetes type 1 is based on the substitution of insulin. Even though the principles of the therapy have not changed so much, still some important changes have occurred in the production and usage of insulin. Lately, the insulin pumps are more frequent in the therapy for Diabetes type 1. The functioning of the pump is based on the continuing delivery of insulin in a small dose ("the basal dose"), that keeps the level of glycemia in the blood constant. The increase of glycemia during the meal is reduced with the additional dose of insulin ("the bolus dose"). The use of the insulin pumps and the continuing glucose sensors has provided an easier and more efficient monitoring of the diabetes, a better metabolic control and a better life quality for the patient and his/her family. This work presents the way of automatic regulation of the basal dose of insulin through the synthesis of the functions of the insulin pump and the continuing glucose sensor. The aim is to give a contribution to the development of the controlling algorithm on the insulin pump for the automatic regulation of the glucose concentration in the blood. This could be a step further which is closer to the delivery of the dose of insulin that is really needed for the basic needs of the organism, and a significant contribution is given to the development of the artificial pancreas.

  16. The Automatic Regulation of the Basal Dose on the Insulin Pump for the Treatment of Patients that have Diabetes Type 1

    Directory of Open Access Journals (Sweden)

    Sifet Mehanović

    2010-05-01

    Full Text Available Diabetes mellitus type 1 is a chronic metabolic disorder, and its main characteristic is Hyperglycemia. It usually occurs in the early years because of the absolute or relative absence of the active insulin that is caused by the autoimmune disease of the β cells of the pancreas. Despite the numerous researches and efforts of the scientists, the therapy for Diabetes type 1 is based on the substitution of insulin. Even though the principles of the therapy have not changed so much, still some important changes have occurred in the production and usage of insulin. Lately, the insulin pumps are more frequent in the therapy for Diabetes type 1. The functioning of the pump is based on the continuing delivery of insulin in a small dose (“the basal dose”, that keeps the level of glycemia in the blood constant. The increase of glycemia during the meal is reduced with the additional dose of insulin (“the bolus dose”. The use of the insulin pumps and the continuing glucose sensors has provided an easier and more efficient monitoring of the diabetes, a better metabolic control and a better life quality for the patient and his/her family.This work presents the way of automatic regulation of the basal dose of insulin through the synthesis of the functions of the insulin pump and the continuing glucose sensor. The aim is to give a contribution to the development of the controlling algorithm on the insulin pump for the automatic regulation of the glucose concentration in the blood. This could be a step further which is closer to the delivery of the dose of insulin that is really needed for the basic needs of the organism, and a significant contribution is given to the development of the artificial pancreas.

  17. Impact of insulin pump on quality of life of diabetic patients

    Directory of Open Access Journals (Sweden)

    Haider Ghazanfar

    2016-01-01

    Full Text Available Aim: Diabetes is an emerging health problem, both in developing and developed countries and has an enormous economic and social impact. The objective of our study was to find the impact of insulin pump on the quality of life of patients with type 2 diabetes (T2D and compare it to the quality of life of patients with T2D using an insulin pen. Subjects and Methods: This is a case–control study which was conducted among patients with T2D presenting between November 2014 and November 2015. A total of 83 patients with T2D, using insulin pump were enrolled in the study as cases and 322 patients with T2D not using insulin pump but using insulin pens were enrolled as controls. Short form-36 quality of life questionnaire was used for data collection. Results: Mean age of patients using insulin pump was 52.49 ± 9.28 while the mean age of patients not using insulin pump was 54.72 ± 16.87. Mean score of all domains in the questionnaire was found to be higher in patients using insulin pump as compared to patients not using insulin pumps (P < 0.05. In 81.1% of the patients, the insulin pump decreased the frequency of hypoglycemic episodes. Conclusion: Insulin pump has significantly improved the quality of life of patients in terms of better self-esteem, decreased stress, and better mood. It has resulted in improved physical health, meal time flexibility, and ease of travel. It allows patient to have more active participation in social and recreational activities improving their personal and family life.

  18. Intensive Insulin Therapy: Tight Blood Sugar Control

    Science.gov (United States)

    ... specific situation. McCulloch DK. General principles of insulin therapy in diabetes mellitus. http://www.uptodate.com/home. Accessed Dec. ... Diabetes Association. http://www.diabetes.org/living-with-diabetes/treatment-and-care/blood-glucose-control/checking-your-blood- ...

  19. Insulin Therapy in Diabetic Hyperglycemic Emergencies

    Directory of Open Access Journals (Sweden)

    Diana Machado Ramírez

    2014-09-01

    Full Text Available Background: diabetic ketoacidosis and hyperglycemic hyperosmolar nonketotic state are two of the most serious metabolic emergencies in diabetic patients. Objective: to identify the type of metabolic complications (diabetic ketoacidosis and hyperglycemic hyperosmolar nonketotic state in order to analyze the patients’ outcome considering the plasma pH levels, as well as the mode of insulin administration. Method: a cross-sectional descriptive study was conducted in 52 patients admitted to the intensive care unit of the Enrique Cabrera Hospital from 2000 to 2007. The variables analyzed included: type of diabetes mellitus, type of acute complication, mode of insulin administration, blood gas analysis and outcome. Results: diabetic ketoacidosis occurred in 57.5 % of the type 1 diabetic patients and in the 42.5 % of the type 2 diabetics. None of the type 1 diabetics developed hyperglycemic hyperosmolar nonketotic state and this complication was observed in 23.0 % of the patients with diabetes type 2. Microdosing was the mode of insulin administration that predominated in both ketoacidosis and hyperglycemic state cases. Mortality was higher in the hyperglycemic state (67 % and using microdoses in the insulin therapy. Conclusions: diabetic ketoacidosis was the major complication. Mortality from diabetic ketoacidosis and hyperglycemic hyperosmolar nonketotic state was high and the mode of insulin administration was inadequate in some patients.

  20. Sensor-augmented pump therapy at 36 months

    DEFF Research Database (Denmark)

    Schmidt, Signe; Nørgaard, Kirsten

    2012-01-01

    This follow-up study investigates the metabolic and psychosocial effects of sensor-augmented pump (SAP) therapy in adults with type 1 diabetes 36 months after therapy start.......This follow-up study investigates the metabolic and psychosocial effects of sensor-augmented pump (SAP) therapy in adults with type 1 diabetes 36 months after therapy start....

  1. ORIGINAL ARTICLES Barriers to initiating insulin therapy in patients ...

    African Journals Online (AJOL)

    Nicky

    opportunities for continuing medical education (CME) and poor patient ... related to insulin therapy, language barriers between doctor and patients, and fear of ..... of primary health care professionals regarding initiation of insulin in primary ...

  2. [Progress in the development of insulin pumps and their advanced automatic functions].

    Science.gov (United States)

    Prázný, Martin

    2015-04-01

    Patients with type 1 diabetes are exposed to permanent burden consisting of careful glucose self-monitoring and precise insulin dosage based on measured glucose values, carbohydrates content in the food and both planned and non-planned physical activity. Erroneous insulin dosing causes frequent both hypoglycemia and hyperglycemia. Hypoglycemia is, however, the most clinically significant complication limiting the optimal diabetes control. Automatic features for insulin dosage integrated in insulin pumps are thus very important. Low glucose suspend (LGS) and Predictive Low Glucose Management (PLGM) use glucose sensor values to prevent hypoglycemia, shorten the time spent in hypoglycemic range and present further step forward to fully closed-loop system of insulin treatment.

  3. Intensive insulin therapy improves insulin sensitivity and mitochondrial function in severely burned children.

    Science.gov (United States)

    Fram, Ricki Y; Cree, Melanie G; Wolfe, Robert R; Mlcak, Ronald P; Qian, Ting; Chinkes, David L; Herndon, David N

    2010-06-01

    To institute intensive insulin therapy protocol in an acute pediatric burn unit and study the mechanisms underlying its benefits. Prospective, randomized study. An acute pediatric burn unit in a tertiary teaching hospital. Children, 4-18 yrs old, with total body surface area burned > or =40% and who arrived within 1 wk after injury were enrolled in the study. Patients were randomized to one of two groups. Intensive insulin therapy maintained blood glucose levels between 80 and 110 mg/dL. Conventional insulin therapy maintained blood glucose patients were included in the data analysis consisting of resting energy expenditure, whole body and liver insulin sensitivity, and skeletal muscle mitochondrial function. Studies were performed at 7 days postburn (pretreatment) and at 21 days postburn (posttreatment). Resting energy expenditure significantly increased posttreatment (1476 +/- 124 to 1925 +/- 291 kcal/m(2) x day; p = .02) in conventional insulin therapy as compared with a decline in intensive insulin therapy. Glucose infusion rate was identical between groups before treatment (6.0 +/- 0.8 conventional insulin therapy vs. 6.8 +/- 0.9 mg/kg x min intensive insulin therapy; p = .5). Intensive insulin therapy displayed a significantly higher glucose clamp infusion rate posttreatment (9.1 +/- 1.3 intensive insulin therapy versus 4.8 +/- 0.6 mg/kg x min conventional insulin therapy, p = .005). Suppression of hepatic glucose release was significantly greater in the intensive insulin therapy after treatment compared with conventional insulin therapy (5.0 +/- 0.9 vs. 2.5 +/- 0.6 mg/kg x min; intensive insulin therapy vs. conventional insulin therapy; p = .03). States 3 and 4 mitochondrial oxidation of palmitate significantly improved in intensive insulin therapy (0.9 +/- 0.1 to 1.7 +/- 0.1 microm O(2)/CS/mg protein/min for state 3, p = .004; and 0.7 +/- 0.1 to 1.3 +/- 0.1 microm O(2)/CS/mg protein/min for state 4, p protocol improves insulin sensitivity and mitochondrial

  4. Adherence to Insulin Pump Behaviors in Young Children With Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Patton, Susana R; Driscoll, Kimberly A; Clements, Mark A

    2017-01-01

    Parents of young children are responsible for daily type 1 diabetes (T1DM) cares including insulin bolusing. For optimal insulin pump management, parents should enter a blood glucose result (SMBG) and a carbohydrate estimate (if food will be consumed) into the bolus advisor in their child's pump to assist in delivering the recommended insulin bolus. Previously, pump adherence behaviors were described in adolescents; we describe these behaviors in a sample of young children. Pump data covering between 14-30 consecutive days were obtained for 116 children. Assessed adherence to essential pump adherence behaviors (eg, SMBG, carbohydrate entry, and insulin use) and adherence to 3 Wizard/Bolus Advisor steps: SMBG-carbohydrate entry-insulin bolus delivered. Parents completed SMBG ≥4 times on 99% of days, bolused insulin ≥3 times on 95% of days, and entered carbohydrates ≥3 times on 93% of days, but they corrected for hyperglycemia (≥250 mg/dl or 13.9 mmol/l) only 63% of the time. Parents completed Wizard/Bolus Advisor steps (SMBG, carbohydrate entry, insulin bolus) within 30 minutes for 43% of boluses. Inverse correlations were found between children's mean daily glucose and the percentage of days with ≥4 SMBG and ≥3 carbohydrate entries as well as the percentage of boluses where all Wizard/Bolus Advisor steps were completed. Parents of young children adhered to individual pump behaviors, but showed some variability in their adherence to Wizard/Bolus Advisor steps. Parents showed low adherence to recommendations to correct for hyperglycemia. Like adolescents, targeting pump behaviors in young children may have the potential to optimize glycemic control.

  5. Comparison Between Individually and Group-Based Insulin Pump Initiation by Time-Driven Activity-Based Costing.

    Science.gov (United States)

    Ridderstråle, Martin

    2017-07-01

    Depending on available resources, competencies, and pedagogic preference, initiation of insulin pump therapy can be performed on either an individual or a group basis. Here we compared the two models with respect to resources used. Time-driven activity-based costing (TDABC) was used to compare initiating insulin pump treatment in groups (GT) to individual treatment (IT). Activities and cost drivers were identified, timed, or estimated at location. Medical quality and patient satisfaction were assumed to be noninferior and were not measured. GT was about 30% less time-consuming and 17% less cost driving per patient and activity compared to IT. As a batch driver (16 patients in one group) GT produced an upward jigsaw-shaped accumulative cost curve compared to the incremental increase incurred by IT. Taking the alternate cost for those not attending into account, and realizing the cost of opportunity gained, suggested that GT was cost neutral already when 5 of 16 patients attended, and that a second group could be initiated at no additional cost as the attendance rate reached 15:1. We found TDABC to be effective in comparing treatment alternatives, improving cost control and decision making. Everything else being equal, if the setup is available, our data suggest that initiating insulin pump treatment in groups is far more cost effective than on an individual basis and that TDABC may be used to find the balance point.

  6. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    Science.gov (United States)

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  7. Model Predictive Control Algorithms for Pen and Pump Insulin Administration

    DEFF Research Database (Denmark)

    Boiroux, Dimitri

    at mealtime, and the case where the insulin sensitivity increases during the night. This thesis consists of a summary report, glucose and insulin proles of the clinical studies and research papers submitted, peer-reviewed and/or published in the period September 2009 - September 2012....... of current closed-loop controllers. In this thesis, we present different control strategies based on Model Predictive Control (MPC) for an artificial pancreas. We use Nonlinear Model Predictive Control (NMPC) in order to determine the optimal insulin and blood glucose profiles. The optimal control problem...

  8. Effect of insulin pump infusion on comprehensive stress state of ...

    African Journals Online (AJOL)

    a control group (120 cases), administered continuous intravenous insulin, and a ... oxidative stress and stress hormone levels were compared between the ... metabolic acidosis and ketonuria, as a result of .... This resulting energy insufficiency.

  9. Design of insulin analogues for meal-related therapy.

    Science.gov (United States)

    Brange, J

    1993-01-01

    The human insulin in replacement therapy has a hexameric structure. Hexamerization of the insulin molecule facilitates biosynthesis and beta-cell storage of insulin, but is unnecessary for biologic activity and appears to contribute to delayed absorption of exogenous insulin from the subcutis. Insulin analogues with reduced self-association that are produced through recombinant DNA techniques have been shown to have in vivo activity comparable to that of human insulin and absorption kinetics characterized by higher and more constant rates of disappearance from the subcutaneous injection site. In preliminary studies in patients receiving insulin therapy, monomeric insulin analogues have been found to provide glycemic control in the postprandial period that is at least equivalent to that of human insulin. Findings in these studies suggest that the use of such analogues may provide meal-related insulin effects closer to those observed in the physiologic state by limiting excessive postprandial glucose excursions and decreasing the risk of late hypoglycemia. Banting and Best revolutionized diabetes therapy 70 years ago with the extraction of insulin from animal pancreas glands (J Lab Clin Med 7:464-472, 1922). Since that time, many refinements of the therapeutic properties of pharmaceutical preparations of the hormone have been introduced. Until recently, however, such advances have been limited to improvements in insulin purity, insulin species, and adjustment of the composition of the vehicle with respect to auxiliary substances and other additives. With the advent of recombinant DNA techniques, it has become possible to optimize the insulin molecule itself for purposes of replacement therapy.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. [Continuous insulin therapy versus multiple insulin injections in the management of type 1 diabetes: a longitutinal study].

    Science.gov (United States)

    Ribeiro, Maria Estela Bellini; Del Roio Liberatore Junior, Raphael; Custodio, Rodrigo; Martinelli Junior, Carlos Eduardo

    2016-01-01

    To compare multiple doses of insulin and continuous insulin infusion therapy as treatment for type 1 diabetes melito. 40 patients with type 1 diabetes melito (21 female) with ages between 10 and 20 years (mean=14.2) and mean duration of diabetes of 7 years used multiple doses of insulin for at least 6 months and after that, continuous insulin infusion therapy for at least 6 months. Each one of the patients has used multiple doses of insulin and continuous insulin infusion therapy. For analysis of HbA1c, mean glycated hemoglobin levels (mHbA1c) were obtained during each treatment period (multiple doses of insulin and continuous insulin infusion therapy period). Although mHbA1c levels were lower during continuous insulin infusion therapy the difference was not statistically significant. During multiple doses of insulin, 14.2% had mHbA1c values below 7.5% vs. 35.71% while on continuous insulin infusion therapy; demonstrating better glycemic control with the use of continuous insulin infusion therapy. During multiple doses of insulin, 15-40 patients have severe hypoglycemic events versus 5-40 continuous insulin infusion therapy. No episodes of ketoacidosis events were recorded. This is the first study with this design comparing multiple doses of insulin and continuous insulin infusion therapy in Brazil showing no significant difference in HbA1c; hypoglycemic events were less frequent during continuous insulin infusion therapy than during multiple doses of insulin and the percentage of patients who achieved a HbA1c less than 7.5% was greater during continuous insulin infusion therapy than multiple doses of insulin therapy. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  11. Pitfalls of insulin pump clocks: technical glitches that may potentially affect medical care in patients with diabetes.

    Science.gov (United States)

    Aldasouqi, Saleh A; Reed, Amy J

    2014-11-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients' visits, and should remind their patients to always verify these settings. © 2014 Diabetes Technology Society.

  12. Insulin and insulin-like growth factor-1 increased in preterm neonates following massage therapy.

    Science.gov (United States)

    Field, Tiffany; Diego, Miguel; Hernandez-Reif, Maria; Dieter, John N I; Kumar, Adarsh M; Schanberg, Saul; Kuhn, Cynthia

    2008-12-01

    To determine if massage therapy increased serum insulin and insulin-like growth factor-1 (IGF-1) in preterm neonates. Forty-two preterm neonates who averaged 34.6 weeks (M = 29.5 wk gestational age; M birth weight = 1237 g) and were in the "grower" (step-down) nursery were randomly assigned to a massage therapy group (body stroking and passive limb movements for three, 15-minute periods per day for 5 days) or a control group that received the standard nursery care without massage therapy. On Days 1 and 5, the serum collected by clinical heelsticks was also assayed for insulin and IGF-1, and weight gain and kilocalories consumed were recorded daily. Despite similar formula intake, the massaged preterm neonates showed greater increases during the 5-day period in (1) weight gain; (2) serum levels of insulin; and (3) IGF-1. Increased weight gain was significantly correlated with insulin and IGF-1. Previous data suggested that preterm infant weight gain following massage therapy related to increased vagal activity, which suggests decreased stress and gastric motility, which may contribute to more efficient food absorption. The data from this study suggest for the first time that weight gain was also related to increased serum insulin and IGF-1 levels following massage therapy. Preterm infants who received massage therapy not only showed greater weight gain but also a greater increase in serum insulin and IGF-1 levels, suggesting that massage therapy might be prescribed for all growing neonates.

  13. Chapter 10: Glucose control: insulin therapy*

    African Journals Online (AJOL)

    Insulin and its analogues lower blood glucose by stimulating peripheral glucose uptake, especially by skeletal muscle and fat, and by inhibiting hepatic glucose production. Insulin inhibits ... control on 2 or 3 oral glucose lowering drugs.

  14. Carbohydrate-to-insulin ratio is estimated from 300-400 divided by total daily insulin dose in type 1 diabetes patients who use the insulin pump.

    Science.gov (United States)

    Kuroda, Akio; Yasuda, Tetsuyuki; Takahara, Mitsuyoshi; Sakamoto, Fumie; Kasami, Ryuichi; Miyashita, Kazuyuki; Yoshida, Sumiko; Kondo, Eri; Aihara, Ken-ichi; Endo, Itsuro; Matsuoka, Taka-aki; Kaneto, Hideaki; Matsumoto, Toshio; Shimomura, Iichiro; Matsuhisa, Munehide

    2012-11-01

    To optimize insulin dose using insulin pump, basal and bolus insulin doses are widely calculated from total daily insulin dose (TDD). It is recommended that total daily basal insulin dose (TBD) is 50% of TDD and that the carbohydrate-to-insulin ratio (CIR) equals 500 divided by TDD. We recently reported that basal insulin requirement is approximately 30% of TDD. We therefore investigated CIR after adjustment of the proper basal insulin rate. Forty-five Japanese patients with type 1 diabetes were investigated during several weeks of hospitalization. The patients were served standard diabetes meals (25-30 kcal/kg of ideal body weight). Each meal omission was done to confirm basal insulin rate. Target blood glucose level was set at 100 and 150 mg/dL before and 2 h after each meal, respectively. After the basal insulin rate was fixed and target blood glucose levels were achieved, TBD, CIR, TDD, and their products were determined. Mean (±SD) blood glucose levels before and 2 h after meals were 121±47 and 150±61 mg/dL, respectively. TDD was 31.5±9.0 U, and TBD was 27.0±6.5% of TDD. CIR×TDD of breakfast was significantly lower than those of lunch and supper (288±73 vs. 408±92 and 387±83, respectively; Plunch and supper in type 1 diabetes patients. These results indicate that the insulin dose has been underestimated by using previously established calculations.

  15. Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.

    Science.gov (United States)

    Rosales, Nicolás; De Battista, Hernán; Vehí, Josep; Garelli, Fabricio

    2018-06-01

    Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus insulin infusion). This paper presents a method for automatic insulin bolus shaping based on insulin-on-board (IOB) as an alternative to conventional bolus dosing. The methodology presented allows the pump to generate the so-called super-bolus (SB) employing a two-compartment IOB dynamic model. The extra amount of insulin to boost the bolus and the basal cutoff time are computed using the duration of insulin action (DIA). In this way, the pump automatically re-establishes basal insulin when IOB reaches its basal level. Thus, detrimental transients caused by manual or a-priori computations are avoided. The potential of this method is illustrated via in-silico trials over a 30 patients cohort in single meal and single day scenarios. In the first ones, improvements were found (standard treatment vs. automatic SB) both in percentage time in euglycemia (75g meal: 81.9 ± 15.59 vs. 89.51 ± 11.95, ρ ≃ 0; 100g meal: 75.12 ± 18.23 vs. 85.46 ± 14.96, ρ ≃ 0) and time in hypoglecymia (75g meal: 5.92 ± 14.48 vs. 0.97 ± 4.15, ρ=0.008; 100g meal: 9.5 ± 17.02 vs. 1.85 ± 7.05, ρ=0.014). In a single day scenario, considering intra-patient variability, the time in hypoglycemia was reduced (9.57 ± 14.48 vs. 4.21 ± 6.18, ρ=0.028) and improved the time in euglycemia (79.46 ± 17.46 vs. 86.29 ± 11.73, ρ=0.007). The automatic IOB-based SB has the potential of a better performance in comparison with the standard treatment, particularly for high glycemic index meals with high carbohydrate content. Both glucose excursion and time spent in hypoglycemia were reduced. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Importance of manually entering blood glucose readings when wireless-compatible meters are not being used with an insulin pump.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Tang, Yuanyuan; Gill, Elizabeth C; Mitchell, Adela; Wright, Nancy; Deeb, Larry C

    2013-07-01

    The objective was to determine if there were differences in blood glucose monitoring (BGM) data downloaded from insulin pumps of patients who use meters that wirelessly transmit data to their insulin pumps (i.e., wireless group) and those who do not (i.e., nonwireless group). Blood glucose monitoring data were downloaded from the meters and insulin pumps of 47 children and adolescents with type 1 diabetes mellitus. Independent and paired t tests compared BGM data downloaded from meters and BGM data downloaded from insulin pumps. There were significant differences in BGM data downloaded from the insulin pumps of patients using wireless meters compared to those using nonwireless meters. Wireless patients appeared to engage in more BGM, had more low and in-range BG readings and fewer very high BG readingss than nonwireless patients. However, a comparison of BGM data downloaded from meters and insulin pumps of nonwireless patients indicated that their insulin pump data significantly underestimated the number of BGM readings conducted, as well as the number of low and in-range readings, while overestimating the number of very high BGM readings. Because patients who use nonwireless-compatible meters do not manually enter their low and in-range BGM readings into the insulin pump, BGM data downloaded only from pumps may provide an incomplete representation of BGM frequency or results. It is recommended that patients use meters that directly communicate with pumps or perform bolus calculations. Patients should be educated about the importance of manually entering all BGM readings if they do not use a wireless-compatible meter with their insulin pump. © 2013 Diabetes Technology Society.

  17. Effects of subcutaneous, low-dose glucagon on insulin-induced mild hypoglycaemia in patients with insulin pump treated type 1 diabetes

    DEFF Research Database (Denmark)

    Ranjan, Ajenthen; Schmidt, S; Madsbad, Sten

    2016-01-01

    AIM: To investigate the dose-response relationship of subcutaneous glucagon administration on plasma glucose and on counterregulatory hormone responses during subcutaneous insulin induced mild hypoglycaemia in patients with type 1 diabetes treated with insulin pumps. MATERIALS AND METHODS: Eight...... hypoglycaemia in patients with type 1 diabetes....... insulin pump treated patients completed a blinded, randomized, placebo-controlled study. Hypoglycaemia was induced in the fasting state by a subcutaneous insulin bolus and when plasma glucose reached 3.4 mmol/l (95%CI 3.2-3.5), a subcutaneous bolus of either 100, 200, 300 µg glucagon or saline...

  18. [Comparison between basal insulin glargine and NPH insulin in patients with diabetes type 1 on conventional intensive insulin therapy].

    Science.gov (United States)

    Pesić, Milica; Zivić, Sasa; Radenković, Sasa; Velojić, Milena; Dimić, Dragan; Antić, Slobodan

    2007-04-01

    Insulin glargine is a long-acting insulin analog that mimics normal basal insulin secretion without pronounced peaks. The aim of this study was to compare insulin glargine with isophane insulin (NPH insulin) for basal insulin supply in patients with type 1 diabetes. A total of 48 type 1 diabetics on long term conventional intensive insulin therapy (IT) were randomized to three different regimens of basal insulin substitution: 1. continuation of NPH insulin once daily at bedtime with more intensive selfmonitoring (n = 15); 2. NPH insulin twice daily (n = 15); 3. insulin glargine once daily (n = 18). Meal time insulin aspart was continued in all groups. Fasting blood glucose (FBG) was lower in the glargine group (7.30+/-0.98 mmol/1) than in the twice daily NPH group (7.47+/-1.06 mmol/1), but without significant difference. FBG was significantly higher in the once daily NPH group (8.44+/-0.85 mmol/l; p < 0.05). HbAlc after 3 months did not change in the once daily NPH group, but decreased in the glargine group (from 7.72+/-0.86% to 6.87+/-0.50%), as well as in the twice daily NPH group (from 7.80+/-0.83% to 7.01+/-0.63%). Total daily insulin doses were similar in all groups but only in the glargine group there was an increase of basal and decrease of meal related insulin doses. The frequency of mild hypoglycemia was significantly lower in the glargine group (6.56+/-2.09) than in both NPH groups (9.0+/-1.65 in twice daily NPH group and 8.13+/-1.30 in other NPH group) (episodes/patients-month, p < 0.05). Basal insulin supplementation in type 1 diabetes mellitus with either twice daily NPH insulin or glargine can result in similar glycemic control when combined with meal time insulin aspart. However, with glargine regimen FBG, HbAlc and frequency of hypoglycemic event are lower. These facts contribute to better patients satisfaction with insulin glargine versus NPH insulin in IIT in type 1 diabetics.

  19. Comparison between basal insulin glargine and NPH insulin in patients with diabetes type 1 on conventional intensive insulin therapy

    Directory of Open Access Journals (Sweden)

    Pešić Milica

    2007-01-01

    Full Text Available Background/Aim. Insulin glargine is a long-acting insulin analog that mimics normal basal insulin secretion without pronounced peaks. The aim of this study was to compare insulin glargine with isophane insulin (NPH insulin for basal insulin supply in patients with type 1 diabetes. Methods. A total of 48 type 1 diabetics on long term conventional intensive insulin therapy (IIT were randomized to three different regimens of basal insulin substitution: 1. continuation of NPH insulin once daily at bedtime with more intensive selfmonitoring (n = 15; 2. NPH insulin twice daily (n = 15; 3. insulin glargine once daily (n = 18. Meal time insulin aspart was continued in all groups. Results. Fasting blood glucose (FBG was lower in the glargine group (7.30±0.98 mmol/l than in the twice daily NPH group (7.47±1.06 mmol/l, but without significant difference. FBG was significantly higher in the once daily NPH group (8.44±0.85 mmol/l; p < 0.05. HbA1c after 3 months did not change in the once daily NPH group, but decreased in the glargine group (from 7.72±0.86% to 6.87±0.50%, as well as in the twice daily NPH group (from 7.80±0.83% to 7.01±0.63%. Total daily insulin doses were similar in all groups but only in the glargine group there was an increase of basal and decrease of meal related insulin doses. The frequency of mild hypoglycemia was significantly lower in the glargine group (6.56±2.09 than in both NPH groups (9.0±1.65 in twice daily NPH group and 8.13±1.30 in other NPH group (episodes/patients-month, p < 0.05. Conclusion. Basal insulin supplementation in type 1 diabetes mellitus with either twice daily NPH insulin or glargine can result in similar glycemic control when combined with meal time insulin aspart. However, with glargine regimen FBG, HbA1c and frequency of hypoglycemic event are lower. These facts contribute to better patients satisfaction with insulin glargine versus NPH insulin in IIT in type 1 diabetics.

  20. Metabolic control after years of completing a clinical trial on sensor-augmented pump therapy.

    Science.gov (United States)

    Quirós, Carmen; Giménez, Marga; Orois, Aida; Conget, Ignacio

    2015-11-01

    Sensor-augmented pump (SAP) therapy has been shown to be effective and safe for improving metabolic control in patients with type 1 diabetes mellitus (T1DM) in a number of trials. Our objective was to assess glycemic control in a group of T1DM patients on insulin pump or SAP therapy after years of participating in the SWITCH (Sensing With Insulin pump Therapy To Control HbA1c) trial and their return to routine medical monitoring. A retrospective, observational study of 20 patients who participated in the SWITCH trial at our hospital from 2008 to 2010. HbA1c values were compared at the start, during (at the end of the periods with/without SAP use - Sensor On/Sensor Off period respectively - of the cross-over design), and 3 years after study completion. HbA1c values of patients who continued SAP therapy (n=6) or only used insulin pump (n=14) were also compared. Twenty patients with T1DM (44.4±9.3 years, 60% women, baseline HbA1c level 8.43±0.55%) were enrolled into the SWITCH study). Three years after study completion, HbA1c level was 7.79±0.77 in patients on pump alone, with no significant change from the value at the end of the Off period of the study (7.85±0.57%; p=0.961). As compared to the end of the On period, HbA1c worsened less in patients who remained on SAP than in those on pump alone (0.18±0.42 vs. 0.55±0.71%; p=0.171), despite the fact that levels were similar at study start (8.41±0.60 vs. 8.47±0.45; p=0.831) and at the end of the On period (7.24±0.48 vs. 7.38±0.61; p=0.566). Frequency of CGM use in patients who continued SAP therapy was high (61.2% of the time in the last 3 months). Our study suggests that the additional benefit of SAP therapy achieved in a clinical trial may persist in the long term in routine clinical care of patients with T1DM. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  1. Clinical evaluation of the use of a multifunctional remotely controlled insulin pump: multicenter observational study.

    Science.gov (United States)

    Boizel, Robert; Pinget, Michel; Lachgar, Karim; Parkin, Christopher G; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-11-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system's advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. © 2014 Diabetes Technology Society.

  2. Clinical Evaluation of the Use of a Multifunctional Remotely Controlled Insulin Pump

    Science.gov (United States)

    Pinget, Michel; Lachgar, Karim; Parkin, Christopher G.; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-01-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system’s advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. PMID:25107708

  3. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  4. Insulin gene therapy for type 1 diabetes mellitus.

    Science.gov (United States)

    Handorf, Andrew M; Sollinger, Hans W; Alam, Tausif

    2015-04-01

    Type 1 diabetes mellitus is an autoimmune disease resulting from the destruction of pancreatic β cells. Current treatments for patients with type 1 diabetes mellitus include daily insulin injections or whole pancreas transplant, each of which are associated with profound drawbacks. Insulin gene therapy, which has shown great efficacy in correcting hyperglycemia in animal models, holds great promise as an alternative strategy to treat type 1 diabetes mellitus in humans. Insulin gene therapy refers to the targeted expression of insulin in non-β cells, with hepatocytes emerging as the primary therapeutic target. In this review, we present an overview of the current state of insulin gene therapy to treat type 1 diabetes mellitus, including the need for an alternative therapy, important features dictating the success of the therapy, and current obstacles preventing the translation of this treatment option to a clinical setting. In so doing, we hope to shed light on insulin gene therapy as a viable option to treat type 1 diabetes mellitus.

  5. Tolerance of centrifuge-simulated suborbital spaceflight in subjects with implanted insulin pumps.

    Science.gov (United States)

    Levin, Dana R; Blue, Rebecca S; Castleberry, Tarah L; Vanderploeg, James M

    2015-04-01

    With commercial spaceflight comes the possibility of spaceflight participants (SFPs) with significant medical conditions. Those with previously untested medical conditions, such as diabetes mellitus (DM) and the use of indwelling medical devices, represent a unique challenge. It is unclear how SFPs with such devices will react to the stresses of spaceflight. This case report describes two subjects with Type I DM using insulin pumps who underwent simulated dynamic phases of spaceflight via centrifuge G force exposure. Two Type I diabetic subjects with indwelling Humalog insulin pumps, a 23-yr-old man averaging 50 u of Humalog daily and a 27-yr-old man averaging 60 u of Humalog daily, underwent seven centrifuge runs over 48 h. Day 1 consisted of two +Gz runs (peak = +3.5 Gz, run 2) and two +Gx runs (peak = +6.0 Gx, run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +Gx and +Gz). Data collected included blood pressure, electrocardiogram, pulse oximetry, neurovestibular evaluation, and questionnaires regarding motion sickness, disorientation, greyout, and other symptoms. Neither subject experienced adverse clinical responses to the centrifuge exposure. Both maintained blood glucose levels between 110-206 mg · dl(-1). Potential risks to SFPs with insulin pump dependent DM include hypo/hyperglycemia, pump damage, neurovestibular dysfunction, skin breakdown, and abnormal stress responses. A search of prior literature did not reveal any previous studies of individuals with DM on insulin pumps exposed to prolonged accelerations. These cases suggest that individuals with conditions dependent on continuous medication delivery might tolerate the accelerations anticipated for commercial spaceflight.

  6. Effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with GDM

    Directory of Open Access Journals (Sweden)

    Liu Jie

    2017-05-01

    Full Text Available Objective: To study the effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with gestational diabetes mellitus (GDM. Methods: Patients with GDM who received insulin therapy between March 2013 and May 2016 were selected as the research subjects and randomly divided into multiple subcutaneous insulin injection (MSII group and continuous subcutaneous insulin pump infusion (CSII group. Before and after treatment, serum glucolipid metabolism as well as inflammation and oxidative stress inexes in placenta were determined respectively. Results: 2 weeks and 4 weeks after treatment, FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of both groups of patients were significantly lower than those before treatment and FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of CSII group were significantly lower than those of MSII group; after delivery, TNF-α, IL-6, ROS and AGEs levels in placenta of CSII group were significantly lower than those of MSII group. Conclusion: Continuous subcutaneous insulin infusion can more effectively improve the glucolipid metabolism and inhibit the inflammation and oxidative stress in placenta of patients with GDM than multiple subcutaneous insulin injection.

  7. Effect of insulin pump and continuous intravenous insulin on ketone body metabolism, blood gas indexes and stress state in patients with diabetic ketoacidosis

    Directory of Open Access Journals (Sweden)

    Hui-Jin Shi

    2017-09-01

    Full Text Available Objective: To study the effect of insulin pump and continuous intravenous insulin on ketone body metabolism, blood gas indexes and stress state in patients with diabetic ketoacidosis. Methods: Patients with diabetic ketoacidosis who were treated in Meizhou Maternal and Child Heath Hospital between May 2014 and March 2017 were selected as the research subjects and randomly divided into the group A who received subcutaneous insulin infusion by insulin pump and the group B who received intravenous small-dose insulin injection by micropump. The indexes of ketone body, blood gas and stress were measured before and after treatment. Results: 12 h and 24 h after treatment, serum β-hydroxybutyrate, MDA, NE, ACTH and Cor contents of both groups of patients were significantly lower than those before treatment while pH, HCO3 - and base excess levels as well as serum SOD, GSH-Px, CAT and TAC contents were significantly higher than those before treatment, and serum β-hydroxybutyrate, MDA, NE, ACTH and Cor contents of group A were significantly lower than those of group B while pH, HCO3 - and base excess levels as well as serum SOD, GSH-Px, CAT and TAC contents were significantly higher than those of group B. Conclusion: Subcutaneous insulin infusion by insulin pump can improve ketone body metabolism, acidosis status and stress state in patients with diabetic ketoacidosis.

  8. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  9. Insulin monotherapy compared with the addition of oral glucose-lowering agents to insulin for people with type 2 diabetes already on insulin therapy and inadequate glycaemic control

    NARCIS (Netherlands)

    Vos, Rimke C; van Avendonk, Mariëlle JP; Jansen, Hanneke; Goudswaard, Alexander N; van den Donk, Maureen; Gorter, Kees; Kerssen, Anneloes; Rutten, Guy EHM

    2016-01-01

    BACKGROUND: It is unclear whether people with type 2 diabetes mellitus on insulin monotherapy who do not achieve adequate glycaemic control should continue insulin as monotherapy or can benefit from adding oral glucose-lowering agents to the insulin therapy. OBJECTIVES: To assess the effects of

  10. [Prevalence of Dental Caries in Type 1 Diabetic Patients Treated with Insulin Pump].

    Science.gov (United States)

    Garcia, Rosana; Coelho, Ana; Paula, Anabela; Marques Ferreira, Manuel; Caramelo, Francisco; Barros, Luísa; Batista, Carla; Melo, Miguel; Silva, Mário Jorge; Carrilho, Eunice

    2016-08-01

    Type 1 diabetes mellitus and oral health are strictly related on a reciprocal basis, and an increased susceptibility to a wide variety of oral diseases is recognised in these patients. The aim of the present study was to establish a relationship between the prevalence of dental caries in Type 1 diabetic patients treated with insulin pump and that of non-diabetic patients. An observational clinical study of analytical and cross-sectional nature was conducted. The sample consisted of 30 adults with diabetes mellitus treated with insulin pump (selected from the Coimbra Hospital and Universitary Centre) and 30 nondiabetic adults (selected from the ones accompanying the diabetic patients). One dentist evaluated all of the patients between January and May of 2015 in the Faculty of Medicine of the University of Coimbra. During the clinical evaluation a case report form adapted to the objectives of the investigation was completed. Data analysis was performed and the significance level was set at 5%. Diabetic patients showed similar levels on the caries and plaque index to non-diabetic patients. There were no statistically significant differences between the two groups as regards oral hygiene habits and frequency of visits to the dentist. Discussão: Although diabetics' diet is less abundant in carbohydrates, which provides a smaller exposure to cariogenic food, the regularity of meals can increase the risk of caries since the critical pH for demineralization is reached frequently throughout the day. However, the existence of a chronic condition may determine a high concern for general preventive care, resulting in an overall improvement of their oral health, which could justify the results. Type 1 diabetic patients treated with insulin pump don't have a higher prevalence of dental caries.

  11. Hypoglycemia Prevention and User Acceptance of an Insulin Pump System with Predictive Low Glucose Management

    DEFF Research Database (Denmark)

    Choudhary, Pratik; Olsen, Birthe S; Conget, Ignacio

    2016-01-01

    was avoided with this strategy, as well as to assess user acceptance of the system and its insulin management features. SUBJECTS AND METHODS: Forty subjects with type 1 diabetes used the system for 4 weeks. We retrospectively evaluated performance of the system, using downloaded pump and sensor data......, and evaluated user acceptance via questionnaires. RESULTS: There were 2,322 suspend before low events (2.1 per subject-day). The mean (± SD) duration of pump suspension events was 56.4 ± 9.6 min, and the mean subsequent sensor glucose (SG) nadir was 71.8 ± 5.2 mg/dL. SG values following 1,930 (83...

  12. The effect of peer support in adults with insulin pump-treated type 1 diabetes

    DEFF Research Database (Denmark)

    Joensen, Lene Eide; Meldgaard Andersen, Merete; Jensen, Sabrina

    2017-01-01

    Aim: The aim of this study was to explore the effects of a flexible and participatory peer support intervention in a clinical setting for adults with type 1 diabetes treated with an insulin pump, focusing on enhancing diabetes-specific social capital. The key questions were as follows: 1) what...... empowerment, diabetes distress, diabetes-specific social support, and diabetes loneliness. HbA1c levels were compared before and after the intervention. Results: Participants experienced enhanced diabetes-specific social capital, diabetes motivation, awareness of personal diabetes practices, and serenity...

  13. A Review of Basal-Bolus Therapy Using Insulin Glargine and Insulin Lispro in the Management of Diabetes Mellitus.

    Science.gov (United States)

    Candido, Riccardo; Wyne, Kathleen; Romoli, Ester

    2018-04-13

    Basal-bolus therapy (BBT) refers to the combination of a long-acting basal insulin with a rapid-acting insulin at mealtimes. Basal insulin glargine 100 U/mL and prandial insulin lispro have been available for many years and there is a substantial evidence base to support the efficacy and safety of these agents when they are used in BBT or basal-plus therapy for patients with type 1 or type 2 diabetes mellitus (T1DM, T2DM). With the growing availability of alternative insulins for use in such regimens, it seems timely to review the data regarding BBT with insulin glargine 100 U/mL and insulin lispro. In patients with T1DM, BBT with insulin glargine plus insulin lispro provides similar or better glycemic control and leads to less nocturnal hypoglycemia compared to BBT using human insulin as the basal and/or prandial component, and generally provides similar glycemic control and rates of severe hypoglycemia to those achieved with insulin lispro administered by continuous subcutaneous insulin infusion (CSII). Studies evaluating BBT with insulin glargine plus insulin lispro in patients with T2DM also demonstrate the efficacy and safety of these insulins. Available data suggest that BBT with insulin glargine and insulin lispro provides similar levels of efficacy and safety in pediatric and adult populations with T1DM and in adult patients and those aged more than 65 years with T2DM. These insulin preparations also appear to be safe and effective for controlling T2DM in people of different ethnicities and in patients with T1DM or T2DM and comorbidities. Eli Lilly and Company.

  14. Myostatin inhibition therapy for insulin-deficient type 1 diabetes.

    Science.gov (United States)

    Coleman, Samantha K; Rebalka, Irena A; D'Souza, Donna M; Deodhare, Namita; Desjardins, Eric M; Hawke, Thomas J

    2016-09-01

    While Type 1 Diabetes Mellitus (T1DM) is characterized by hypoinsulinemia and hyperglycemia, persons with T1DM also develop insulin resistance. Recent studies have demonstrated that insulin resistance in T1DM is a primary mediator of the micro and macrovascular complications that invariably develop in this chronic disease. Myostatin acts to attenuate muscle growth and has been demonstrated to be elevated in streptozotocin-induced diabetic models. We hypothesized that a reduction in mRNA expression of myostatin within a genetic T1DM mouse model would improve skeletal muscle health, resulting in a larger, more insulin sensitive muscle mass. To that end, Akita diabetic mice were crossed with Myostatin(Ln/Ln) mice to ultimately generate a novel mouse line. Our data support the hypothesis that decreased skeletal muscle expression of myostatin mRNA prevented the loss of muscle mass observed in T1DM. Furthermore, reductions in myostatin mRNA increased Glut1 and Glut4 protein expression and glucose uptake in response to an insulin tolerance test (ITT). These positive changes lead to significant reductions in resting blood glucose levels as well as pronounced reductions in associated diabetic symptoms, even in the absence of exogenous insulin. Taken together, this study provides a foundation for considering myostatin inhibition as an adjuvant therapy in T1DM as a means to improve insulin sensitivity and blood glucose management.

  15. Insulin Pumps

    Science.gov (United States)

    ... Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home Food MyFoodAdvisor ... Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In My Community Home ...

  16. Role of insulin in regulation of Na+-/K+-dependent ATPase activity and pump function in corneal endothelial cells.

    Science.gov (United States)

    Hatou, Shin; Yamada, Masakazu; Akune, Yoko; Mochizuki, Hiroshi; Shiraishi, Atsushi; Joko, Takeshi; Nishida, Teruo; Tsubota, Kazuo

    2010-08-01

    The Na(+)-/K(+)-dependent ATPase (Na,K-ATPase) expressed in the basolateral membrane of corneal endothelial cells plays an important role in the pump function of the corneal endothelium. The role of insulin in the regulation of Na,K-ATPase activity and pump function in corneal endothelial cells was investigated. Confluent monolayers of mouse corneal endothelial cells were exposed to insulin. ATPase activity was evaluated by spectrophotometric measurement of phosphate released from ATP with the use of ammonium molybdate; Na,K-ATPase activity was defined as the portion of total ATPase activity sensitive to ouabain. Pump function was measured with the use of a Ussing chamber; pump function attributable to Na,K-ATPase activity was defined as the portion of the total short-circuit current sensitive to ouabain. Western blot analysis and immunocytochemistry were performed to measure the expression of the Na,K-ATPase alpha(1)-subunit. Insulin increased the Na,K-ATPase activity and pump function of cultured corneal endothelial cells. These effects were blocked by protein kinase C (PKC) inhibitors and protein phosphatases 1 and 2A inhibitor. Western blot analysis indicated that insulin decreased the ratio of the inactive Na,K-ATPase alpha(1)-subunit. Immunocytochemistry indicated that insulin increased the cell surface expression of the Na,K-ATPase alpha(1)-subunit. These results suggest that insulin increases the Na,K-ATPase activity and pump function of cultured corneal endothelial cells. The effect of insulin is mediated by PKC and presumably results in the activation of PP1, 2A, or both, which are essential for activating Na,K-ATPase by alpha(1)-subunit dephosphorylation.

  17. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  18. The nature and meaning of insulin pump use in emerging adults with type 1 diabetes.

    Science.gov (United States)

    Hood, Donna G; Duke, Gloria

    2015-05-01

    Objective. The purpose of this study is to investigate the meaning of living with an insulin pump for the management of type 1 diabetes during the period of emerging adulthood. Through a phenomenological narrative, this study contributes to the reflective understanding of the everyday life experiences of this population. Methods. A hermeneutic phenomenological design was used for this study of nine emerging adults (aged 19-24 years). Data were generated through face-to-face interviews and analyzed using the phenomenological approach of Max van Manen. Results. Four themes represent the essence of the day-to-day experiences of these emerging adults: seeking control, becoming responsible, staying connected, and accepting me. Conclusions. An in-depth understanding of the meaning of daily experiences with insulin pump technology has the potential to promote a developmentally appropriate approach to this age-group. The human understanding gained through this study is essential to the development of evidence-based practice guidelines and resources for this vulnerable population.

  19. Allergic contact dermatitis caused by isobornyl acrylate in OmniPod, an innovative tubeless insulin pump.

    Science.gov (United States)

    Raison-Peyron, Nadia; Mowitz, Martin; Bonardel, Nathalie; Aerts, Olivier; Bruze, Magnus

    2018-04-10

    The frequency of allergic contact dermatitis caused by (meth)acrylates is increasing worldwide, and isobornyl acrylate (IBOA) has been identified as a culprit sensitizer in FreeStyle Libre, a medical device used by diabetic patients. To report on 4 patients sensitized to IBOA contained in OmniPod, a new, tubeless insulin pump, and to describe the clinical and chemical analytical work-up. Four patients with eczematous skin eruptions after using OmniPod, including 2 with previous adverse skin reactions to FreeStyle Libre, were patch tested with a baseline series and additional (meth)acrylates, including IBOA in several concentrations and/or vehicles. Gas chromatography-mass spectrometry (GC-MS) was used to identify the presence of IBOA in OmniPod. All patients were shown to be sensitized to IBOA. GC-MS identified IBOA in OmniPod, with the highest concentrations being found in the unit itself and not in the adhesive patch. The OmniPod tubeless insulin pump is another source of IBOA, and its use may lead to primary sensitization to this acrylate, or may provoke elicitation of allergic contact dermatitis in previously sensitized patients. Our cases highlight the need to obtain satisfactory cooperation from pharmaceutical companies involved in the manufacture of these widely used medical devices. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Relative effectiveness of insulin pump treatment over multiple daily injections and structured education during flexible intensive insulin treatment for type 1 diabetes: cluster randomised trial (REPOSE).

    Science.gov (United States)

    2017-03-30

    Objective  To compare the effectiveness of insulin pumps with multiple daily injections for adults with type 1 diabetes, with both groups receiving equivalent training in flexible insulin treatment. Design  Pragmatic, multicentre, open label, parallel group, cluster randomised controlled trial (Relative Effectiveness of Pumps Over MDI and Structured Education (REPOSE) trial). Setting  Eight secondary care centres in England and Scotland. Participants  Adults with type 1 diabetes who were willing to undertake intensive insulin treatment, with no preference for pumps or multiple daily injections. Participants were allocated a place on established group training courses that taught flexible intensive insulin treatment ("dose adjustment for normal eating," DAFNE). The course groups (the clusters) were then randomly allocated in pairs to either pump or multiple daily injections. Interventions  Participants attended training in flexible insulin treatment (using insulin analogues) structured around the use of pump or injections, followed for two years. Main outcome measures  The primary outcomes were a change in glycated haemoglobin (HbA1c) values (%) at two years in participants with baseline HbA1c value of ≥7.5% (58 mmol/mol), and the proportion of participants achieving an HbA1c value of intention to treat analysis, of which 235 (119 pump and 116 injection) had baseline HbA1c values of ≥7.5%. Glycaemic control and rates of severe hypoglycaemia improved in both groups. The mean change in HbA1c at two years was -0.85% with pump treatment and -0.42% with multiple daily injections. Adjusting for course, centre, age, sex, and accounting for missing values, the difference was -0.24% (-2.7 mmol/mol) in favour of pump users (95% confidence interval -0.53 to 0.05, P=0.10). Most psychosocial measures showed no difference, but pump users showed greater improvement in treatment satisfaction and some quality of life domains (dietary freedom and daily hassle) at 12 and 24

  1. Insulin adherence behaviours and barriers in the multinational Global Attitudes of Patients and Physicians in Insulin Therapy study.

    Science.gov (United States)

    Peyrot, M; Barnett, A H; Meneghini, L F; Schumm-Draeger, P-M

    2012-05-01

    To examine patient and physician beliefs regarding insulin therapy and the degree to which patients adhere to their insulin regimens. Internet survey of 1250 physicians (600 specialists, 650 primary care physicians) who treat patients with diabetes and telephone survey of 1530 insulin-treated patients (180 with Type 1 diabetes, 1350 with Type 2 diabetes) in China, France, Japan, Germany, Spain, Turkey, the UK or the USA. One third (33.2%) of patients reported insulin omission/non-adherence at least 1 day in the last month, with an average of 3.3 days. Three quarters (72.5%) of physicians report that their typical patient does not take their insulin as prescribed, with a mean of 4.3 days per month of basal insulin omission/non-adherence and 5.7 days per month of prandial insulin omission/non-adherence. Patients and providers indicated the same five most common reasons for insulin omission/non-adherence: too busy; travelling; skipped meals; stress/emotional problems; public embarrassment. Physicians reported low patient success at initiating insulin in a timely fashion and adjusting insulin doses. Most physicians report that many insulin-treated patients do not have adequate glucose control (87.6%) and that they would treat more aggressively if not for concern about hypoglycaemia (75.5%). Although a majority of patients (and physicians) regard insulin treatment as restrictive, more patients see insulin treatment as having positive than negative impacts on their lives. Glucose control is inadequate among insulin-treated patients, in part attributable to insulin omission/non-adherence and lack of dose adjustment. There is a need for insulin regimens that are less restrictive and burdensome with lower risk of hypoglycaemia. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  2. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Results: Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = −5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = −2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. Conclusions: The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. PMID:25670847

  3. AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY 2018 POSITION STATEMENT ON INTEGRATION OF INSULIN PUMPS AND CONTINUOUS GLUCOSE MONITORING IN PATIENTS WITH DIABETES MELLITUS.

    Science.gov (United States)

    Grunberger, George; Handelsman, Yehuda; Bloomgarden, Zachary T; Fonseca, Vivian A; Garber, Alan J; Haas, Richard A; Roberts, Victor L; Umpierrez, Guillermo E

    2018-03-01

    This document represents the official position of the American Association of Clinical Endocrinologists and American College of Endocrinology. Where there are no randomized controlled trials or specific U.S. FDA labeling for issues in clinical practice, the participating clinical experts utilized their judgment and experience. Every effort was made to achieve consensus among the committee members. Position statements are meant to provide guidance, but they are not to be considered prescriptive for any individual patient and cannot replace the judgment of a clinician. AACE/ACE Task Force on Integration of Insulin Pumps and Continuous Glucose Monitoring in the Management of Patients With Diabetes Mellitus Chair George Grunberger, MD, FACP, FACE Task Force Members Yehuda Handelsman, MD, FACP, FNLA, MACE Zachary T. Bloomgarden, MD, MACE Vivian A. Fonseca, MD, FACE Alan J. Garber, MD, PhD, FACE Richard A. Haas, MD, FACE Victor L. Roberts, MD, MBA, FACP, FACE Guillermo E. Umpierrez, MD, CDE, FACP, FACE Abbreviations: AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology A1C = glycated hemoglobin BGM = blood glucose monitoring CGM = continuous glucose monitoring CSII = continuous subcutaneous insulin infusion DM = diabetes mellitus FDA = Food & Drug Administration MDI = multiple daily injections T1DM = type 1 diabetes mellitus T2DM = type 2 diabetes mellitus SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR 3 = Sensor-Augmented Pump Therapy for A1C Reduction phase 3 trial.

  4. Lixisenatide as add-on therapy to basal insulin

    Directory of Open Access Journals (Sweden)

    Brown DX

    2013-12-01

    Full Text Available Dominique Xavier Brown, Emma Louise Butler, Marc Evans Diabetes Department, University Hospital Llandough, Cardiff, UK Abstract: Many patients with type 2 diabetes mellitus do not achieve target glycosylated hemoglobin A1c levels despite optimally titrated basal insulin and satisfactory fasting plasma glucose levels. Current evidence suggests that HbA1c levels are dictated by both basal glucose and postprandial glucose levels. This has led to a consensus that postprandial glucose excursions contribute to poor glycemic control in these patients. Lixisenatide is a once-daily, prandial glucagon-like peptide 1 (GLP-1 receptor agonist with a four-fold affinity for the GLP-1 receptor compared with native GLP-1. Importantly, lixisenatide causes a significant delay in gastric emptying time, an important determinant of the once-daily dosing regimen. An exendin-4 mimetic with six lysine residues removed at the C-terminal, lixisenatide has pronounced postprandial glucose-lowering effects, making it a novel incretin agent for use in combination with optimally titrated basal insulin. Lixisenatide exerts profound effects on postprandial glucose through established mechanisms of glucose-dependent insulin secretion and glucagon suppression in combination with delayed gastric emptying. This review discusses the likely place that lixisenatide will occupy in clinical practice, given its profound effects on postprandial glucose and potential to reduce glycemic variability. Keywords: lixisenatide, add-on therapy, insulin, GLP-1 receptor agonist, postprandial glucose, pharmacodynamics

  5. Insulin pump treatment; increasing prevalence, and predictors for better metabolic outcome in Danish children and adolescents with type 1 diabetes

    DEFF Research Database (Denmark)

    Olsen, Birthe; Johannesen, J; Fredheim, S

    2015-01-01

    glucose (SMBG) measurements, a higher number of daily boluses, and a higher percentage of bolus insulin were all related to a lower HbA1c. CONCLUSION: The percentage of children on pumps (CSII) is CSII treatment is associated with a significantly lower Hba1c, achieved just after treatment initiation...

  6. Insulin Therapy for the Management of Hyperglycemia in Hospitalized Patients

    Science.gov (United States)

    McDonnell, Marie E.; Umpierrez, Guillermo E.

    2013-01-01

    It has long been established that hyperglycemia with or without a prior diagnosis of diabetes increases both mortality and disease-specific morbidity in hospitalized patients1–4 and that goal-directed insulin therapy can improve outcomes.5–9 During the past decade, since the widespread institutional adoption of intensified insulin protocols after the publication of a landmark trial,5,10 the pendulum in the inpatient diabetes literature has swung away from achieving intensive glucose control and toward more moderate and individualized glycemic targets.11,12 This change in clinical practice is the result of several factors, including challenges faced by hospitals to coordinate glycemic control across all levels of care,13,14 publication of negative prospective trials,15,16 revised recommendations from professional organizations,17,18 and increasing evidence on the deleterious effect of hypoglycemia.19–22 This article reviews the pathophysiology of hyperglycemia during illness, the mechanisms for increased complications and mortality due to hyperglycemia and hypoglycemia, beneficial mechanistic effects of insulin therapy and provides updated recommendations for the inpatient management of diabetes in the critical care setting and in the general medicine and surgical settings.23,24 PMID:22575413

  7. Managing insulin therapy during exercise in type 1 diabetes mellitus.

    Science.gov (United States)

    Toni, Sonia; Reali, Maria Francesca; Barni, Federica; Lenzi, Lorenzo; Festini, Filippo

    2006-01-01

    Exercise is integral to the life of T1DM subjects. Several factors influence the metabolic response to exercise in these patients. Despite physical and psychological benefits of exercise, its hypo- and hyperglycemic effects may cause discouragement from participation in sports and games. To use existing evidence from literature to provide practical indications for the management of insulin therapy in subjects with T1DM who practice sports or physical activities. Bibliographic research was performed on PubMed and the main Systematic Review and Guidelines database were also searched. Existing guidelines are useful but the exact adjustments of insulin dose must be made on an individual basis and these adjustments can be made only by "trial and error" approach. These clinical indications may be a starting point from which health care providers can find practical advices for each patient.

  8. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes: Results From a Pilot Study

    OpenAIRE

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This singl...

  9. Early intranasal insulin therapy halts progression of neurodegeneration: progress in Alzheimer's disease therapeutics.

    Science.gov (United States)

    de la Monte, Suzanne M

    Evaluation of Craft S, Baker LD, Montine TJ, Minoshima S, Watson GS, Claxton A, et al. Intranasal Insulin Therapy for Alzheimer Disease and Amnestic Mild Cognitive Impairment: A Pilot Clinical Trial. Arch Neurol . 2011 Sep 12. Alzheimer's disease is associated with brain insulin deficiency and insulin resistance, similar to the problems in diabetes. If insulin could be supplied to the brain in the early stages of Alzheimer's, subsequent neurodegeneration might be prevented. Administering systemic insulin to elderly non-diabetics poses unacceptable risks of inadvertant hypoglycemia. However, intranasal delivery directs the insulin into the brain, avoiding systemic side-effects. This pilot study demonstrates both efficacy and safety of using intranasal insulin to treat early Alzheimer's and mild cognitive impairment, i.e. the precursor to Alzheimer's. Significant improvements in learning, memory, and cognition occured within a few months, but without intranasal insulin, brain function continued to deteriorate in measurable degrees. Intranasal insulin therapy holds promise for halting progression of Alzheimer's disease.

  10. Continuous subcutaneous insulin infusion therapy and multiple daily insulin injections in type 1 diabetes mellitus: a comparative overview and future horizons.

    Science.gov (United States)

    Thabit, Hood; Hovorka, Roman

    2016-01-01

    Continuous subcutaneous insulin infusion (CSII) therapy is currently accepted as a treatment strategy for type 1 diabetes. Transition from multiple daily injection therapy (MDI; including basal-bolus regimens) to CSII is based on expectations of better metabolic control and fewer hypoglycaemic events. Evidence to date has not been always conclusive. Evidence for CSII and MDI in terms of glycaemic control, hypoglycaemia and psychosocial outcomes is reviewed in the adult and paediatric population with type 1 diabetes. Findings from studies on threshold-based insulin pump suspension and predictive low glucose management (PLGM) are outlined. Limitations of current CSII application and future technological developments are discussed. Glycaemic control and quality of life (QOL) may be improved by CSII compared to MDI depending on baseline HbA1c and hypoglycaemia rates. Future studies are expected to provide evidence on clinical and cost effectiveness in those who will benefit the most. Training, structured education and support are important to benefit from CSII. Novel technological approaches linking continuous glucose monitoring (CGM) and CSII may help mitigate against frequent hypoglycaemia in those at risk. Development of glucose-responsive automated closed-loop insulin delivery systems may reduce the burden of disease management and improve outcomes in type 1 diabetes.

  11. Is insulin the most effective injectable antihyperglycaemic therapy?

    Science.gov (United States)

    Buse, J B; Peters, A; Russell-Jones, D; Furber, S; Donsmark, M; Han, J; MacConell, L; Maggs, D; Diamant, M

    2015-02-01

    The recent type 2 diabetes American Diabetes Association/European Association for the Study of Diabetes (ADA/EASD) position statement suggested insulin is the most effective glucose-lowering therapy, especially when glycated haemoglobin (HbA1c) is very high. However, randomized studies comparing glucagon-like peptide-1 receptor agonists (GLP-1RAs) exenatide once-weekly [OW; DURATION-3 (Diabetes therapy Utilization: Researching changes in A1c, weight, and other factors Through Intervention with exenatide ONce-Weekly)] and liraglutide once-daily [OD; LEAD-5 (Liraglutide Effect and Action in Diabetes)] with insulin glargine documented greater HbA1c reduction with GLP-1RAs, from baseline HbA1c ∼8.3% (67 mmol/mol). This post hoc analysis of DURATION-3 and LEAD-5 examined changes in HbA1c, fasting glucose and weight with exenatide OW or liraglutide and glargine, by baseline HbA1c quartile. Descriptive statistics were provided for change in HbA1c, fasting glucose, weight, and insulin dose, and subjects (%) achieving HbA1c <7.0%, by baseline HbA1c quartile. Inferential statistical analysis on the effect of baseline HbA1c quartile was performed for change in HbA1c. An analysis of covariance (ANCOVA) model was used to evaluate similarity in change in HbA1c across HbA1c quartiles. At 26 weeks, in both studies, HbA1c reduction, and proportion of subjects reaching HbA1c <7.0%, were similar or numerically greater with the GLP-1RAs than glargine for all baseline HbA1c quartiles. Fasting glucose reduction was similar or numerically greater with glargine. Weight decreased with both GLP-1RAs across all quartiles; subjects taking glargine gained weight, more at higher baseline HbA1c. Adverse events were uncommon although gastrointestinal events occurred more frequently with GLP-1RAs. HbA1c reduction with the GLP-1RAs appears at least equivalent to that with basal insulin, irrespective of baseline HbA1c. This suggests that liraglutide and exenatide OW may be appropriate

  12. Early intranasal insulin therapy halts progression of neurodegeneration: progress in Alzheimer’s disease therapeutics

    OpenAIRE

    de la Monte, Suzanne M.

    2012-01-01

    Evaluation of Craft S, Baker LD, Montine TJ, Minoshima S, Watson GS, Claxton A, et al. Intranasal Insulin Therapy for Alzheimer Disease and Amnestic Mild Cognitive Impairment: A Pilot Clinical Trial. Arch Neurol. 2011 Sep 12. Alzheimer’s disease is associated with brain insulin deficiency and insulin resistance, similar to the problems in diabetes. If insulin could be supplied to the brain in the early stages of Alzheimer’s, subsequent neurodegeneration might be prevented. ...

  13. Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system.

    Science.gov (United States)

    Jones, Susan M; Quarry, Jill L; Caldwell-McMillan, Molly; Mauger, David T; Gabbay, Robert A

    2005-04-01

    We attempted to identify an optimal insulin pump meal bolus by comparing postprandial sensor glucose values following three methods of insulin pump meal bolusing for a consistent pizza meal. Twenty-four patients with type 1 diabetes participated in a study to compare postprandial glucose values following three meal bolus regimens for a consistent evening pizza meal. Each participant utilized the following insulin lispro regimens on consecutive evenings, and glucose values were tracked by the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA): (a) single-wave bolus (100% of insulin given immediately); (b) 4-h dual-wave bolus (50% of insulin given immediately and 50% given over a 4-h period); and (c) 8-h dual-wave bolus (50% of insulin given immediately and 50% given over a 8-h period). Total insulin bolus amount was kept constant for each pizza meal. Divergence in blood glucose among the regimens was greatest at 8-12 h. The 8-h dual-wave bolus provided the best glycemic control and lowest mean glucose values (singlewave bolus, 133 mg/dL; 4-h dual-wave bolus, 145 mg/dL; 8-h dual-wave bolus, 104 mg/dL), leading to a difference in mean glucose of 29 mg/dL for the single-wave bolus versus the 8-h dual-wave bolus and 42 mg/dL for the 4-h dual-wave bolus versus the 8-h dual-wave bolus. The lower mean glucose in the 8-h dual-wave bolus was not associated with any increased incidence of hypoglycemia. Use of a dual-wave bolus extended over an 8-h period following a pizza meal provided significantly less postprandial hyperglycemia in the late postprandial period (8-12 h) with no increased risk of hypoglycemia.

  14. Insulin therapy for type 2 diabetes - are we there yet? The d-Nav® story.

    Science.gov (United States)

    Hodish, I

    2018-01-01

    Insulin replacement therapy is mostly used by patients with type 2 diabetes who become insulin deficient and have failed other therapeutic options. They comprise about a quarter of those with diabetes, endures the majority of the complications and consumes the majority of the resources. Adequate insulin replacement therapy can prevent complications and reduce expenses, as long as therapy goals are achieved and maintained. Sadly, these therapy goals are seldom achieved and outcomes have not improved for decades despite advances in pharmacotherapy and technology. There is a growing recognition that the low success rate of insulin therapy results from intra-individual and inter-individual variations in insulin requirements. Total insulin requirements per day vary considerably between patients and constantly change without achieving a steady state. Thus, the key element in effective insulin therapy is unremitting and frequent dosage adjustments that can overcome those dynamics. In practice, insulin adjustments are done sporadically during outpatient clinic. Due to time constraints, providers are not able to deliver appropriate insulin dosage optimization. The d-Nav® Insulin Guidance Service has been developed to provide appropriate insulinization in insulin users without increasing the burden on healthcare systems. It relies on dedicated clinicians and a spectrum of technological solutions. Patients are provided with a handheld device called d-Nav® which advises them what dose of insulin to administer during each injection and automatically adjust insulin dosage when needed. The d-Nav care specialists periodically follow-up with users through telephone calls and in-person consultations to bestow user confidence, correct usage errors, triage, and identify uncharacteristic clinical courses. The following review provide details about the service and its clinical outcomes.

  15. Obscure bleeding colonic duplication responds to proton pump inhibitor therapy.

    Science.gov (United States)

    Jacques, Jérémie; Projetti, Fabrice; Legros, Romain; Valgueblasse, Virginie; Sarabi, Matthieu; Carrier, Paul; Fredon, Fabien; Bouvier, Stéphane; Loustaud-Ratti, Véronique; Sautereau, Denis

    2013-09-21

    We report the case of a 17-year-old male admitted to our academic hospital with massive rectal bleeding. Since childhood he had reported recurrent gastrointestinal bleeding and had two exploratory laparotomies 5 and 2 years previously. An emergency abdominal computed tomography scan, gastroscopy and colonoscopy, performed after hemodynamic stabilization, were considered normal. High-dose intravenous proton pump inhibitor (PPI) therapy was initiated and bleeding stopped spontaneously. Two other massive rectal bleeds occurred 8 h after each cessation of PPI which led to a hemostatic laparotomy after negative gastroscopy and small bowel capsule endoscopy. This showed long tubular duplication of the right colon, with fresh blood in the duplicated colon. Obscure lower gastrointestinal bleeding is a difficult medical situation and potentially life-threatening. The presence of ulcerated ectopic gastric mucosa in the colonic duplication explains the partial efficacy of PPI therapy. Obscure gastrointestinal bleeding responding to empiric anti-acid therapy should probably evoke the diagnosis of bleeding ectopic gastric mucosa such as Meckel's diverticulum or gastrointestinal duplication, and gastroenterologists should be aware of this potential medical situation.

  16. Lipid profiles, inflammatory markers, and insulin therapy in youth with type 2 diabetes

    Science.gov (United States)

    Data regarding atherogenic dyslipidemia and the inflammation profile in youth with type 2 diabetes is limited and the effect of insulin therapy on these variables has not previously been studied in youth. We determined the impact of insulin therapy on lipid and inflammatory markers in youth with poo...

  17. How efficient is sliding-scale insulin therapy? Problems with a 'cookbook' approach in hospitalized patients.

    Science.gov (United States)

    Katz, C M

    1991-04-01

    Sliding-scale insulin therapy is seldom the best way to treat hospitalized diabetic patients. In the few clinical situations in which it is appropriate, close attention to details and solidly based scientific principles is absolutely necessary. Well-organized alternative approaches to insulin therapy usually offer greater efficiency and effectiveness.

  18. Use of metformin earlier in pregnancy predicts supplemental insulin therapy in women with gestational diabetes.

    Science.gov (United States)

    McGrath, Rachel T; Glastras, Sarah J; Hocking, Samantha; Fulcher, Gregory R

    2016-06-01

    The use of metformin in gestational diabetes is safe and effective, yet some women require additional insulin therapy to achieve glycaemic targets. We found a significant association between earlier gestational age at initiation of metformin therapy and the necessity for supplemental insulin in women treated with metformin during pregnancy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Continuous subcutaneous insulin infusion (CSII) therapy at Derby Teaching Hospitals: sustained benefits in glucose control.

    Science.gov (United States)

    Anyanwagu, U; Olaoye, H; Jennings, P; Ashton-Cleary, S; Sugunendran, S; Hughes, D; Idris, I; Wilmot, E G

    2017-08-01

    In the short term, continuous subcutaneous insulin infusion (CSII) has been associated with improved glycaemic control, reduced hypoglycaemia and improved quality of life (QOL). However, limited data are available on its long-term benefits, particularly in the UK. We aimed to assess the impact of CSII on longer term outcomes. Patient-level data were obtained for CSII users at Derby Teaching Hospitals, UK. Patient confidence and satisfaction questionnaires using the Likert scale were used to assess confidence in self-management. Comparative statistics were conducted using Pearson's chi-square and Student's t-tests. Some 258 CSII users were identified (60.1% female, mean age 43.9 ± 13.4 years). Overall, there was significant decrease in HbA 1c from 78 mmol/mol (9.3 ± 2.0%) at baseline, to 69 mmol/mol (8.5 ± 1.3%) at 6 months [mean difference (md): -0.64; 95% confidence interval (95% CI): -0.91 to -0.37; P quality of care received in the insulin pump service. CSII therapy led to a sustained long-term improvement in glycaemic control in addition to a reduction in self-reported hypoglycaemia. © 2017 Diabetes UK.

  20. The effectiveness of continuous subcutaneous insulin pumps with continuous glucose monitoring in outpatient adolescents with type 1 diabetes: A systematic review.

    Science.gov (United States)

    Matsuda, Erin; Brennan, Patricia

    2012-01-01

    . Haemoglobin A1C is the most commonly used measurement for patients with type 1 diabetes . It refers to the measurement of the amount of glucose bound to haemoglobin. It is an average of blood glucose levels for the last 120 days, which is consistent with the average life span of a red blood cell (RBC).Compensation for the lack of insulin-secreting βeta-cells is accomplished through administration of insulin. For adolescents, insulin dosing is based on pubescent status, age, weight, activity level, and amount of carbohydrates consumed . Insulin administration, carbohydrate counting, and correction of hyperglycemia are necessary for maintaining glycemic control. Insulin can be administered through multiple daily injections (MDI) of rapid, intermediate and long-acting insulin .Another form of insulin delivery is the Continuous Subcutaneous Insulin Infusion (CSII), also known as an insulin pump, which is designed to meet physiological requirements through programmable basal rates and bolus doses . CSII's utilise rapid-acting insulin and establish a basal rate, which replaces the need for long-acting insulin. Bolus dosing is accomplished through adjusting the pump and is utilised to account for nutritional intake as well as hyperglycemia correction. Adjustments are also made for physical activity and exercise, as this can affect glucose levels . All patients considered in this systematic review will be utilising insulin pumps.In 2006, the United States had more than 35,000 patients, under the age of 21 years, receiving insulin therapy through an insulin pump . In Europe, the percentage of people with type 1 diabetes utilising a CSII is lower, potentially due to variation in health care coverage . There are various forms of insulin pumps, all with similar capabilities including a dose calculator for high blood glucose correction and carbohydrate ratios, programming software, and several other features . Software and programming is specific to each manufacturer. Basal rate

  1. The Rationale for Insulin Therapy in Alzheimer’s Disease

    Directory of Open Access Journals (Sweden)

    Samo Ribarič

    2016-05-01

    Full Text Available Alzheimer’s disease (AD is the most common form of dementia, with a prevalence that increases with age. By 2050, the worldwide number of patients with AD is projected to reach more than 140 million. The prominent signs of AD are progressive memory loss, accompanied by a gradual decline in cognitive function and premature death. AD is the clinical manifestation of altered proteostasis. The initiating step of altered proteostasis in most AD patients is not known. The progression of AD is accelerated by several chronic disorders, among which the contribution of diabetes to AD is well understood at the cell biology level. The pathological mechanisms of AD and diabetes interact and tend to reinforce each other, thus accelerating cognitive impairment. At present, only symptomatic interventions are available for treating AD. To optimise symptomatic treatment, a personalised therapy approach has been suggested. Intranasal insulin administration seems to open the possibility for a safe, and at least in the short term, effective symptomatic intervention that delays loss of cognition in AD patients. This review summarizes the interactions of AD and diabetes from the cell biology to the patient level and the clinical results of intranasal insulin treatment of cognitive decline in AD.

  2. Insulin initiation status of primary care physicians in Turkey, barriers to insulin initiation and knowledge levels about insulin therapy: A multicenter cross-sectional study.

    Science.gov (United States)

    Ates, Elif; Set, Turan; Saglam, Zuhal; Tekin, Nil; Karatas Eray, Irep; Yavuz, Erdinc; Sahin, Mustafa Kursat; Selcuk, Engin Burak; Cadirci, Dursun; Cubukcu, Mahcube

    2017-10-01

    Our aim was to evaluate the insulin initiation status, barriers to insulin initiation and knowledge levels about treatment administered by primary care physicians (PCP). We conducted our study in accordance with a multicenter, cross-sectional design in Turkey, between July 2015 and July 2016. A questionnaire inquiring demographic features, status of insulin initiation, obstacles to insulin initiation and knowledge about therapy of the PCPs was administered during face-to-face interviews. 84 PCPs (19%) (n=446, mean age=41.5±8.4years, 62.9% male and 90.0% ministry certified family physicians) initiated insulin therapy in the past. Most of the stated primary barriers (51.9%, n=230) were due to the physicians. The most relevant barrier was "lack of clinical experience" with a rate of 19% (n=84 of the total). The average total knowledge score was 5.7±2.0 for the family medicine specialist, and 3.8±2.1 for the ministry certified family physicians (p=0.000, maximum knowledge score could be 10). The status of insulin initiation in Turkey by the primary care physicians is inadequate. Medical education programs and health care systems may require restructuring to facilitate insulin initiation in primary care. Copyright © 2017 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  3. Bubble formation occurs in insulin pumps in response to changes in ambient temperature and atmospheric pressure but not as a result of vibration.

    Science.gov (United States)

    Lopez, Prudence E; King, Bruce R; Goss, Peter W; Chockalingam, Ganesh

    2014-01-01

    Bubble formation in insulin pump giving sets is a common problem. We studied change in temperature, change in atmospheric pressure, and vibration as potential mechanisms of bubble formation. 5 Animas 2020 pumps with 2 mL cartridges and Inset II infusion systems, 5 Medtronic Paradigm pumps with 1.8 mL cartridge and Quickset and 3 Roche Accu-chek pumps with 3.15 mL cartridges were used. Temperature study: insulin pumps were exposed to a temperature change from 4°C to 37°C. Pressure study: insulin pumps were taken to an altitude of 300 m. Vibration study: insulin pumps were vigorously shaken. All were observed for bubble formation. Bubble formation was observed with changes in temperature and atmospheric pressure. Bubble formation did not occur with vibration. Changes in insulin temperature and atmospheric pressure are common and may result in bubble formation. Vibration may distribute bubbles but does not cause bubble formation.

  4. Modern approach to basal-bolus therapy with glargine and glulisine insulin analoguesin various age groups

    Directory of Open Access Journals (Sweden)

    Natalya Nikitichna Volevodz

    2013-03-01

    Full Text Available DCCT (Diabetes Control and Complications Trial study established that intensified insulin therapy in multiple daily injections (MDI or continuous insulin infusion (CSII regimens substantially reduce both development and progression of complications in patients with type 1 diabetes mellitus (T1DM as compared to conventional insulin therapy. Insulin analogues possess better pharmacokinetic and pharmacodynamic characteristics than unmodified human insulin agents. These characteristics are beneficial for management of diabetes mellitus, allowing better glycemic outcomes with lower incidence of hypoglycemia.Current review discusses specifics of therapy with glargine (Lantus? and glulisine (Apidra? insulin analogues. Authors analyzed available to date results from corresponding clinical trials in children, adolescents and adults. Pharmacoeconomic aspects and matters of dosage of glargine and glulisine are further addressed.

  5. Effects of 12 weeks' treatment with a proton pump inhibitor on insulin secretion, glucose metabolism and markers of cardiovascular risk in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Hove, K D; Brøns, Charlotte; Færch, Kai Erik Vinther

    2013-01-01

    Recent studies suggest that proton pump inhibitor treatment may increase insulin secretion and improve glucose metabolism in type 2 diabetes. In a randomised double-blind prospective placebo-controlled 2 × 2 factorial study, we examined the effect of esomeprazole on insulin secretion, HbA(1c...

  6. Is reducing variability of blood glucose the real but hidden target of intensive insulin therapy?

    Science.gov (United States)

    Egi, Moritoki; Bellomo, Rinaldo; Reade, Michael C

    2009-01-01

    Since the first report that intensive insulin therapy reduced mortality in selected surgical critically ill patients, lowering of blood glucose levels has been recommended as a means of improving patient outcomes. In this initial Leuven trial, blood glucose control by protocol using insulin was applied to 98.7% of patients in the intensive group but to only 39.2% (P dimension of glucose management, a possible mechanism by which an intensive insulin protocol exerts its putative beneficial effects, and an important goal of glucose management in the intensive care unit. Clinicians need to be aware of this controversy when considering the application of intensive insulin therapy and interpreting future trials.

  7. Acceptance of insulin therapy: a long shot? Psychological insulin resistance in primary care

    NARCIS (Netherlands)

    Woudenberg, Y. J. C.; Lucas, C.; Latour, C.; Scholte Op Reimer, W. J. M.

    2012-01-01

    Diabet. Med. 29, 796802 (2012) Abstract Aim To explore which factors are associated with psychological insulin resistance in insulin-naive patients with Type 2 diabetes in primary care. Methods A sample of 101 insulin-naive patients with Type 2 diabetes completed self-administered questionnaires

  8. Insulin therapy refusal among type II diabetes mellitus patients in Kubang Pasu district, Kedah, Malaysia

    Science.gov (United States)

    Tan, Wei Leong; Asahar, Siti Fairus; Harun, Noor Liani

    2015-01-01

    INTRODUCTION Diabetes mellitus is a rising non-communicable disease in Malaysia. Insulin therapy refusal is a challenge for healthcare providers, as it results in delayed insulin initiation. This study was conducted to determine the prevalence of insulin therapy refusal and its associated factors. METHODS This cross-sectional study was conducted at seven public health clinics in Kubang Pasu district of Kedah, Malaysia, from March to October 2012. A newly developed and validated questionnaire was used and participants were selected via systematic random sampling. Only patients diagnosed with type II diabetes mellitus (T2DM) and under the public health clinic care in Kubang Pasu were included in the study. Multiple logistic regression was used to study the association between insulin therapy refusal and its associated factors. RESULTS There were 461 respondents and the response rate was 100%. Among these 461 patients with T2DM, 74.2% refused insulin therapy. The most common reason given for refusal was a lack of confidence in insulin injection (85.4%). Multiple logistic regression revealed that respondents who had secondary education were 55.0% less likely to refuse insulin therapy than those who had primary education or no formal education (adjusted odds ratio [OR] 0.45, 95% confidence interval [CI] 0.25–0.82, p = 0.009). There was also a significant inverse association between glycated haemoglobin (HbA1c) level and insulin therapy refusal (adjusted OR 0.87, 95% CI 0.76–1.00, p = 0.047). CONCLUSION Insulin therapy refusal is common in Kubang Pasu. Educational status and HbA1c level should be taken into consideration when counselling patients on insulin therapy initiation. PMID:25532511

  9. Intranasal Insulin Therapy for Cognitive Impairment and Neurodegeneration: Current State of the Art

    Science.gov (United States)

    de la Monte, Suzanne M.

    2015-01-01

    Introduction Growing evidence supports the concept that insulin resistance plays an important role in the pathogenesis of cognitive impairment and neurodegeneration, including in Alzheimer's disease (AD). The metabolic hypothesis has led to the development and utilization of insulin- and insulin agonist-based treatments. Therapeutic challenges faced include the ability to provide effective treatments that do not require repeated injections and also minimize potentially hazardous off-target effects. Areas covered This review covers the role of intra-nasal insulin therapy for cognitive impairment and neurodegeneration, particularly Alzheimer's disease. The literature reviewed focuses on data published within the past 5 years as this field is evolving rapidly. The author provides evidence that brain insulin resistance is an important and early abnormality in Alzheimer's disease, and that increasing brain supply and utilization of insulin improves cognition and memory. Emphasis was placed on discussing outcomes of clinical trials and interpreting discordant results to clarify the benefits and limitations of intranasal insulin therapy. Expert Opinion Intranasal insulin therapy can efficiently and directly target the brain to support energy metabolism, myelin maintenance, cell survival, and neuronal plasticity, which begin to fail in the early stages of neurodegeneration. Efforts must continue toward increasing the safety, efficacy, and specificity of intranasal insulin therapy. PMID:24215447

  10. Negative appraisals of insulin therapy are common among adults with Type 2 diabetes using insulin: Results from Diabetes MILES - Australia cross-sectional survey

    DEFF Research Database (Denmark)

    Holmes-Truscott, E.; Holmes-Truscott, E.; Skinner, T. C.

    2015-01-01

    Aim: To identify insulin therapy appraisals among adults with Type 2 diabetes using insulin and how negative appraisals relate to clinical, self-care and psychosocial outcomes. Methods: Diabetes MILES - Australia 2011 was a national survey of adults with diabetes, focused on behavioural...... and psychosocial issues. Subgroup analyses were conducted on the responses of 273 adults with Type 2 diabetes using insulin (46% women; mean ± sd age: 59 ± 9 years; diabetes duration: 12 ± 7 years; years using insulin: 4 ± 4). They completed validated measures of insulin therapy appraisals (ITAS), depression (PHQ......; 51% that insulin causes weight gain; 39% that they have 'failed to manage' their diabetes. Those with the greatest and least 'ITAS negative' scores did not differ by diabetes duration or years using insulin, or by average number of insulin injections or blood glucose checks per day. Those with more...

  11. Sensor Augmented Pump Therapy Use in Type 1 Diabetes Mellitus

    LENUS (Irish Health Repository)

    Carolan, E

    2016-11-01

    Tight metabolic control in Type 1 Diabetes Mellitus (T1DM) reduces incidence and delays progression of micro-vascular complications. Severe hypoglycaemia remains a significant barrier to achieving optimal diabetes control. Continuous subcutaneous insulin infusion (CSII) systems refine insulin delivery with programmable basal rates and mealtime bolusing

  12. Effectiveness of insulin therapy in people with Type 2 diabetes in the Hoorn Diabetes Care System

    NARCIS (Netherlands)

    Mast, M.R.; Walraven, I.; Hoekstra, T.; Jansen, A P D; van der Heijden, A.A.W.A.; Elders, Petra J M; Heine, Robert J; Dekker, J M; Nijpels, G.; Hugtenburg, J.G.

    AIMS: To identify HbA1c trajectories after the start of insulin treatment and to identify clinically applicable predictors of the response to insulin therapy. METHODS: The study population comprised 1203 people with Type 2 diabetes included in the Hoorn Diabetes Care System (n = 9849). Inclusion

  13. Effectiveness of insulin therapy in people with Type 2 diabetes in the Hoorn Diabetes Care System.

    NARCIS (Netherlands)

    Mast, M.R.; Walraven, L.; Hoekstra, T.; Jansen, A.P.D.; Heijden, A.A.W.A. van der; Elders, P.J.M.; Heine, R.J.; Dekker, J.M.; Nijpels, G.; Hugtenburg, J.G.

    2016-01-01

    Aims To identify HbA1c trajectories after the start of insulin treatment and to identify clinically applicable predictors of the response to insulin therapy. Methods The study population comprised 1203 people with Type 2 diabetes included in the Hoorn Diabetes Care System (n = 9849). Inclusion

  14. Glucose Control: non-insulin therapies* 9.1: Drug Summary ...

    African Journals Online (AJOL)

    Glucose Control: non-insulin therapies in 2017 SEMDSA Guideline for the Management of Type 2 Diabetes. Guideline ... Weight neutral or causes modest weight loss (-1.2kg). No weight ..... Older patients with multiple comorbidities. • Patients ...

  15. Examination of Psychosocial and Physiological Risk for Bulimic Symptoms in Youth With Type 1 Diabetes Transitioning to an Insulin Pump: A Pilot Study.

    Science.gov (United States)

    Peterson, Claire M; Young-Hyman, Deborah; Fischer, Sarah; Markowitz, Jessica T; Muir, Andrew B; Laffel, Lori M

    2018-01-01

    This study tested hypotheses drawn from a risk model positing that psychosocial risk plus disease-related and treatment factors contribute to bulimic symptoms in youth with type 1 diabetes (T1D) transitioning to an insulin pump. The goal of this study was to examine whether disease-related factors, particularly disease- and treatment-based disruption in hunger and satiety, contribute to report of bulimic symptoms in youth with T1D after accounting for psychosocial risk factors. 43 youth (ages 10-17, 54% female) with established T1D were recruited before transition from multiple daily injections to insulin-pump therapy from three tertiary pediatric diabetes centers. Participants completed measures of bulimic symptoms, depressive symptoms dietary restraint, and the Diabetes Treatment and Satiety Scale, a diabetes-specific questionnaire assessing hunger and satiety cues and eating behavior in response to blood glucose levels and treatment. Hierarchical multiple regression was used to assess contributions of psychosocial and disease-based risk to report of bulimic symptoms. After assessing the contributions of body mass index, body image dissatisfaction, and dietary restraint, a significant 2-way interaction emerged between depression and diabetes-related uncontrollable hunger related to bulimic symptoms (β = 1.82, p < .01). In addition to psychosocial risk, disease- and treatment-based hunger and satiety dysregulation appear to be important factors contributing to report of bulimic symptoms in youth with T1D. These preliminary findings have significant treatment implications for bulimic symptoms in youth with T1D. © The Author 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Terbutaline pump maintenance therapy after threatened preterm labour for reducing adverse neonatal outcomes.

    Science.gov (United States)

    Chawanpaiboon, Saifon; Laopaiboon, Malinee; Lumbiganon, Pisake; Sangkomkamhang, Ussanee S; Dowswell, Therese

    2014-03-23

    After successful inhibition of threatened preterm labour women are at high risk of recurrent preterm labour. Terbutaline pump maintenance therapy has been used to reduce adverse neonatal outcomes. This review replaces an earlier Cochrane review, published in 2002, which is no longer being updated by the team. To determine the effectiveness of terbutaline pump maintenance therapy after threatened preterm labour in reducing adverse neonatal outcomes. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2014) and reference lists of retrieved studies. Randomised controlled trials comparing terbutaline pump therapy with alternative therapy, placebo, or no therapy after arrest of threatened preterm labour. Two review authors independently assessed the studies for inclusion and then extracted data as eligible for inclusion in qualitative and quantitative synthesis (meta-analysis). Four studies were included with a total of 234 women randomised. The overall methodological quality of the included studies was mixed; two studies provided very little information on study methods, there was high sample attrition in one study and in three studies the risk of performance bias was high. We found no strong evidence that terbutaline maintenance therapy offered any advantages over saline placebo or oral terbutaline maintenance therapy in reducing adverse neonatal outcomes by prolonging pregnancy among women with arrested preterm labour. The mean difference (MD) for gestational age at birth was -0.14 weeks (95% confidence interval (CI) -1.66 to 1.38) for terbutaline pump therapy compared with saline placebo pump for two trials combined. One trial reported a risk ratio (RR) of 1.17 (95% CI 0.79 to 1.73) for preterm birth (less than 37 completed weeks) and a RR of 0.97 (95% CI 0.51 to 1.84) of very preterm birth (less than 34 completed weeks) for terbutaline pump compared with saline placebo pump. We found no evidence that terbutaline pump therapy was

  17. Initiating insulin therapy in children and adolescents with type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Subhash Kumar Wangnoo

    2015-01-01

    Full Text Available The primary clinical goals to be achieved with insulin initiation are elimination of ketosis and hyperglycemia with prevention of chronic complications. Insulin therapy is the mainstay in management of type 1 diabetes, which should be aimed at achieving good glycemic control, with achievement of hemoglobin A1c (HbA1c <7.5%, pre-meal self-monitored blood glucose (SMBG of 90-130 mg/dL, bed time SMBG of 100-140 mg/dL, mean blood glucose level of 120-160 mg/dL and no ketonuria. Two classes of insulin are available for use in T1DM viz. bolus/prandial insulins (rapid-acting insulins and short-acting insulins and basal insulins (intermediate-acting insulin and long-acting insulin. Insulin glargine and glulisine can be used in children above 6 years, lispro in children above 3 years and detemir and aspart in children above 2 years. The caution for hypoglycemia should be exercised while prescribing them. Degludec is currently not approved for pediatric use. The initial insulin regimen should comprise of ≥2 daily bolus and ≥1 basal insulin injections. Insulin intensification would be required if the initial regimen fails, which can be achieved by increasing frequency of long and rapid acting insulin analogues. The American Diabetes Association guidelines recommend HbA1c targets of <8.0% for children <6 years of age, ≤7.5% for children 6 to 12 years of age, and ≤7.0% for adolescents, 12-18 years of age. However, the evidence is now in favor of a single target HbA1c of ≤7.5% for all children and adolescents <19 years of age.

  18. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  19. Early insulin therapy in patients with type 2 diabetes mellitus

    African Journals Online (AJOL)

    Type 2 diabetes mellitus (T2DM) is an insulin-insufficient disease characterised ... complications.1–4 Early in the onset of T2DM there is development of relative insulin ..... position statement of the American Diabetes Association (ADA) and.

  20. Treatment duration (persistence) of basal insulin supported oral therapy (BOT) in Type-2 diabetic patients: comparison of insulin glargine with NPH insulin.

    Science.gov (United States)

    Quinzler, Renate; Ude, Miriam; Franzmann, Alexandra; Feldt, Sandra; Schüssel, Katrin; Leuner, Kristina; Müller, Walter E; Dippel, Franz-Werner; Schulz, Martin

    2012-01-01

    To compare the persistence (treatment duration) of basal insulin supported oral therapy (BOT) using insulin glargine (GLA) or NPH insulin (NPH) in Type-2 diabetic patients. This retrospective cohort study reports results from an analysis of claims data from prescriptions for ambulatory patients within the German Statutory Health Insurance scheme. The study is based on claims data from more than 80% of German community pharmacies. Treatment duration until switching to a basal bolus treatment regimen (intensified conventional insulin therapy: ICT) was determined in insulin-naïve patients who began treatment with BOT using GLA or NPH between 01/2003 and 12/2006. A total of 97,998 patients (61,070 GLA and 36,928 NPH) were included. Within the observation period, 23.5% of GLA patients and 28.0% of NPH patients switched from BOT to ICT. The upper quartile of probability of continuation of therapy (the 75th percentile) was reached after 769 days in GLA patients and after 517 days in NPH patients. Therefore, the risk of switching to ICT was significantly higher with NPH compared to GLA: hazard ratios were 1.34 (99% CI: 1.29-1.38; unadjusted) and 1.22 (99% CI: 1.18-1.27) after adjustment for predefined covariates. Various sensitivity analyses using modified inclusion criteria and endpoint definitions were applied and these confirmed the initial results. Type-2 diabetic patients under BOT with GLA stayed significantly longer on the initial therapy before switching to ICT than patients on BOT using NPH.

  1. Identifying and meeting the challenges of insulin therapy in type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Sorli C

    2014-07-01

    Full Text Available Christopher Sorli,1,* Michael K Heile2,*1Billings Clinic Research Center, Billings, MT, USA; 2The Family Medical Group Glenway, Cincinnati, OH, USA*Both authors contributed equally to this workAbstract: Type 2 diabetes mellitus (T2DM is a chronic illness that requires clinical recognition and treatment of the dual pathophysiologic entities of altered glycemic control and insulin resistance to reduce the risk of long-term micro- and macrovascular complications. Although insulin is one of the most effective and widely used therapeutic options in the management of diabetes, it is used by less than one-half of patients for whom it is recommended. Clinician-, patient-, and health care system-related challenges present numerous obstacles to insulin use in T2DM. Clinicians must remain informed about new insulin products, emerging technologies, and treatment options that have the potential to improve adherence to insulin therapy while optimizing glycemic control and mitigating the risks of therapy. Patient-related challenges may be overcome by actively listening to the patient's fears and concerns regarding insulin therapy and by educating patients about the importance, rationale, and evolving role of insulin in individualized self-treatment regimens. Enlisting the services of Certified Diabetes Educators and office personnel can help in addressing patient-related challenges. Self-management of diabetes requires improved patient awareness regarding the importance of lifestyle modifications, self-monitoring, and/or continuous glucose monitoring, improved methods of insulin delivery (eg, insulin pens, and the enhanced convenience and safety provided by insulin analogs. Health care system-related challenges may be improved through control of the rising cost of insulin therapy while making it available to patients. To increase the success rate of treatment of T2DM, the 2012 position statement from the American Diabetes Association and the European

  2. Prospective randomized study for optimal insulin therapy in type 2 diabetic patients with secondary failure

    Directory of Open Access Journals (Sweden)

    Tojo Katsuyoshi

    2008-05-01

    Full Text Available Abstract Background The large clinical trials proved that Basal-Bolus (BB insulin therapy was effective in the prevention of diabetic complications and their progression. However, BB therapy needs multiple insulin injections per a day. In this regard, a biphasic insulin analogue needs only twice-daily injections, and is able to correct postprandial hyperglycemia. Therefore it may achieve the blood glucose control as same as that of BB therapy and prevent the diabetic complications including macroangiopathy. Methods In PROBE (Prospective, Randomized, Open, Blinded-Endpoint design, forty-two type 2 diabetic patients (male: 73.8%, median(inter quartile range age: 64.5(56.8~71.0years with secondary failure of sulfonylurea (SU were randomly assigned to BB therapy with a thrice-daily insulin aspart and once-daily basal insulin (BB group or to conventional therapy with a twice-daily biphasic insulin analogue (30 Mix group, and were followed up for 6 months to compare changes in HbA1c, daily glycemic profile, intima-media thickness (IMT of carotid artery, adiponectin levels, amounts of insulin used, and QOL between the two groups. Results After 6 months, HbA1c was significantly reduced in both groups compared to baseline (30 Mix; 9.3(8.1~11.3 → 7.4(6.9~8.7%, p Conclusion Both BB and 30 mix group produced comparable reductions in HbA1c in type 2 diabetic patients with secondary failure. There was no significant change in IMT as an indicator of early atherosclerotic changes between the two groups. The basal-bolus insulin therapy may not be necessarily needed if the type 2 diabetic patients have become secondary failure. Trial registration Current Controlled Trials number, NCT00348231

  3. Reexamining the Hypoglycemia Fear Survey for Parents of Young Children in a Sample of Children Using Insulin Pumps.

    Science.gov (United States)

    Patton, Susana R; Noser, Amy E; Clements, Mark A; Dolan, Lawrence M; Powers, Scott W

    2017-02-01

    We update the psychometric properties of the Hypoglycemia Fear Survey-Parents of Young Children (HFS-PYC), a 26-item measure of parents' hypoglycemia fear for young children using an insulin pump. We combined three similar datasets for the analyses. The data analyzed included parents' responses to the HFS-PYC and a demographic form. For a subset of children (n = 91), we also analyzed self-monitoring of blood glucose data. We used confirmatory factor analysis (CFA) to confirm the measure's original factor structure. Additional analyses examined reliability and validity of a revised HFS-PYC for parents of young children using pumps. We analyzed data from 116 parents (93% mothers). Mean child age and HbA1c were 5.2 ± 1.3 years and 8.2% ± 1.1%, respectively. CFA identified a 22-item two-factor solution (χ 2 (208, n = 116) = 368.688, P 0.65). Correlations revealed significant negative associations between current HFS-PYC worry scores and children's mean daily blood glucose and percent of very high glucose levels per day, suggesting less fear among parents of young children with elevated glycemic levels. In addition, there was a positive association with the percent of glucose levels in target, suggesting greater hypoglycemia fear among parents of children who have better control. Results provide preliminary evidence for the reliability and validity of a reduced 22-item HFS-PYC for parents of children using insulin pumps.

  4. Combination therapy in type 2 diabetes mellitus: adding empagliflozin to basal insulin

    Directory of Open Access Journals (Sweden)

    Andrew Ahmann

    2015-11-01

    Full Text Available Type 2 diabetes mellitus (T2DM management is complex, with few patients successfully achieving recommended glycemic targets with monotherapy, most progressing to combination therapy, and many eventually requiring insulin. Sodium glucose cotransporter 2 (SGLT2 inhibitors are an emerging class of antidiabetes agents with an insulin-independent mechanism of action, making them suitable for use in combination with any other class of antidiabetes agents, including insulin. This review evaluates a 78-week, randomized, double-blind, placebo-controlled trial investigating the impact of empagliflozin, an SGLT2 inhibitor, as add-on to basal insulin in patients with inadequate glycemic control on basal insulin, with or without metformin and/or a sulfonylurea. Empagliflozin added on to basal insulin resulted in significant and sustained reductions in glycated hemoglobin (HbA1c levels compared with placebo. Empagliflozin has previously been shown to induce weight loss, and was associated with sustained weight loss in this study. This combination therapy was well tolerated, with similar levels of hypoglycemic adverse events in the empagliflozin and placebo groups over the 78-week treatment period. Urinary tract infections and genital infections, side effects associated with SGLT2 inhibitors, were reported more commonly in the empagliflozin group; however, such events led to treatment discontinuation in very few patients. These findings suggest that, with their complementary mechanisms of action, empagliflozin added on to basal insulin may be a useful treatment option in patients on basal insulin who need additional glycemic control without weight gain.

  5. Safety of the batteries and power units used in insulin pumps: A pilot cross-sectional study by the Association for the Study of Innovative Diabetes Treatment in Japan.

    Science.gov (United States)

    Murata, Takashi; Nirengi, Shinsuke; Sakane, Naoki; Kuroda, Akio; Hirota, Yushi; Matsuhisa, Munehide; Namba, Mitsuyoshi; Kobayashi, Tetsuro

    2017-10-21

    We investigated the safety of the batteries and power units used in insulin pumps in Japan. A self-administered questionnaire was sent to the 201 members of the Association for Innovative Diabetes Treatment in Japan. A total of 56 members responded, and among the 1,499 active devices, 66 had episodes of trouble related to the batteries and power units. The ratio of reported troubles to the number of insulin pumps was significantly higher in insulin pumps with a continuous glucose monitoring sensor compared with insulin pumps without a continuous glucose monitoring sensor (odds ratio 2.82, P batteries varied; alkaline batteries purchased at drug stores and other shops accounted for 19.7%. Termination of battery life within 72 h of use was reported most frequently (50.0%), suspension of the insulin pump (21.2%) and leakage of the battery fluid (4.5%) followed. A total of 53.2% of the reported insulin pumps needed to be replaced, and 37.1% of them recovered after replacement of the battery. As trouble related to the batteries and power units of insulin pumps was frequent, practical guidance should be provided to respective patients regarding the use of reliable batteries, and to be well prepared for unexpected insulin pump failure. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  6. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.

    Science.gov (United States)

    Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro

    2015-12-01

    Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  7. Insulin

    Science.gov (United States)

    ... For Consumers Home For Consumers Consumer Information by Audience For Women Women's Health Topics Insulin Share Tweet ... I start having side effects? What is my target blood sugar level? How often should I check ...

  8. Novel simple insulin delivery device reduces barriers to insulin therapy in type 2 diabetes: results from a pilot study.

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C; Mader, Julia K; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R

    2015-05-01

    The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = -5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = -2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. © 2015 Diabetes Technology Society.

  9. [Perception of insulin therapy in uncontrolled patients with type 2 diabetes mellitus].

    Science.gov (United States)

    Leyva Jiménez, Rafael; Hernández Zambrano, Gustavo; Ibarra Maldonado, Silvia; Ibarra Ramírez, Carlos Tomás

    2016-10-01

    To determine the perception of insulin therapy by patients with uncontrolled type2 diabetes mellitus, who have been treated with oral hypoglycaemic agents or insulin. Prospective comparative cross-sectional study. Family Medicine Unit No. 53 León, Guanajuato of Mexican Institute of Social Security. Patients between 40 and 80years old with uncontrolled type2 mellitus diabetes, treated with insulin or oral hypoglycaemic agents. Perception was assessed using the insulin treatment appraisal scale (ITAS). The rating of the survey is from 20 to 100 points, as such that when score increases the greater is the negative opinion. A sample of 459 diabetes patients were interviewed and split into 2 groups of patients according to their treatment. The OH group were patients treated with oral hypoglycaemic drugs only (56.9%), and the IN group were patients treated with insulin alone or combined with an oral hypoglycaemic (43.1%). Perception score was significantly higher in OH group (56.95±7.78 versus 49.55±8.89 points) than in the IN group (P1). The perception of insulin therapy was worse in patients treated with only oral hypoglycaemic agents than in patients using insulin. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  10. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  11. Sensor-Augmented Insulin Pumps and Hypoglycemia Prevention in Type 1 Diabetes

    DEFF Research Database (Denmark)

    Steineck, Isabelle; Ranjan, Ajenthen; Nørgaard, Kirsten

    2017-01-01

    prevention. We present evidence from randomized trials, observational studies, and meta-analyses including nonpregnant individuals with type 1 diabetes mellitus. We also outline concerns regarding SAPs with and without automated insulin suspension. There is evidence that SAP treatment reduces episodes...

  12. Barriers towards insulin therapy in type 2 diabetic patients: results of an observational longitudinal study

    Directory of Open Access Journals (Sweden)

    Kulzer Bernd

    2010-10-01

    Full Text Available Abstract Background The course of barriers towards insulin therapy was analysed in three different groups of type 2 diabetic patients. This observational longitudinal study surveyed a three-month follow-up. Methods Participants in this study totalled 130 type 2 diabetic patients. The first subgroup was on insulin therapy at baseline (group 1: n = 57, age 55.6 ± 8.7 yrs, disease duration 12.7 ± 7.2 yrs, HbA1c 8.5 ± 1.6% and remained on insulin at follow-up. Of an initial 73 insulin-naïve patients, 44 were switched to insulin therapy (group 2: age 58.1 ± 6.8 yrs, disease duration 7.7 ± 5.0 yrs, HbA1c 9.1 ± 1.7% and 29 patients remained on an oral regimen (group 3: age 52.7 ± 10.7 yrs, disease duration 5.3 ± 4.6 yrs, HbA1c 8.3 ± 1.4%. Barriers towards insulin therapy were measured using the Insulin Treatment Appraisal Scale (ITAS. As generic instruments of health related quality of life patients completed also the Problem Areas of Diabetes Questionnaire (PAID, the WHO-5 Well-Being Scale (WHO-5, the Centre for Epidemiologic Studies Depression Scale (CES-D and the Trait Version of the State Trait Anxiety Inventory (STAI at baseline and at three-month follow-up. Results At the three-month follow-up, HbA1c had improved in all three groups (7.7 ± 1.2% vs. 7.1 ± 1.1% vs. 6.7 ± 0.8%. The course of negative appraisal of insulin therapy was significantly different in the three groups (p > .003: the ITAS score increased in patients remained on oral antidiabetic drugs (51.2 ± 12.2 to 53.6 ± 12.3, whereas it decreased in patients switched to insulin therapy (49.2 ± 9.8 to 46.2 ± 9.9 or remained on insulin treatment (45.8 ± 8.3 to 44.5 ± 8.0. Diabetes-related distress, trait anxiety, and well-being, showed a similar course in all three groups. The depression score improved significantly in patients switched to insulin treatment compared with patients remaining on insulin therapy. Conclusions In summary, this study suggests that a negative

  13. Efficacy and safety of insulin pump treatment in adult T1DM patients--influence of age and social environment.

    Science.gov (United States)

    Grzanka, Małgorzata; Matejko, Bartłomiej; Cyganek, Katarzyna; Kozek, Elżbieta; Małecki, Maciej T; Klupa, Tomasz

    2012-01-01

    Continuous subcutaneous insulin infusion (CSII) via personal insulin pump is a valuable therapeutic tool in T1DM patients. However, adherence to recommended CSII-related behaviours may be of concern to young adults with intensive, variable daily activities (students, young professionals). The aim of this observational study was to estimate treatment outcomes in young adult patients with T1DM, and compare them with older individuals. Overall, 140 adults with T1DM on CSII were examined, divided into 2 subgroups: 77 patients younger than 26 years of age (mean 20.6 years) and 63 older subjects (mean 39.0). We compared the glycaemic control in both groups of T1DM subjects and analyzed treatment attitudes to identify potentially modifiable behaviours influencing the efficacy of the treatment. The younger individuals were characterized by significantly worse treatment outcomes, compared to the older ones: the mean HbA1c levels were 7.6 ± 1.3% and 6.9±1.3% (p=0.00001), while the mean glucose levels based on glucometer downloads were 161±33.6 mg/dL and 136±21.8 mg/dL (p=0.00001), respectively. The frequency of self-monitoring of blood glucose (SMBG) was lower in younger individuals (5.3±2.1 vs. 7.0±2.8 daily, p=0.0005, respectively); they were also less frequently used advanced pump functions, e.g. the bolus calculator (48% vs. 67% users, p=0.0014, respectively). The efficacy of CSII treatment observed in young T1DM adults was worse than in older patients. The reason for this phenomenon remains unclear, it may be due simply to age-dependend behaviours, to social environment, or both.

  14. Early insulin therapy in patients with type 2 diabetes mellitus ...

    African Journals Online (AJOL)

    Type 2 diabetes mellitus (T2DM) is a progressive disease characterised by beta cell dysfunction and insulin resistance. Beta cell dysfunction progresses to beta cell failure. Many patients with T2DM are managed with oral agents until complications develop. 'Clinical inertia' in T2DM, defined as lack of initiation or ...

  15. Insulin therapy and quality of life. A review

    DEFF Research Database (Denmark)

    Pouwer, Francois; Hermanns, Norbert

    2009-01-01

    Three central goals in the treatment of diabetes mellitus are (1) the avoidance of hyperglycaemia to prevent the development or progression of diabetes complications over time, (2) the avoidance of hypoglycaemia and (3) the maintenance or achievement of good quality of life. Insulin is the most...

  16. Glucose-Responsive Implantable Polymeric Microdevices for "Smart" Insulin Therapy of Diabetes

    Science.gov (United States)

    Chu, Michael Kok Loon

    Diabetes mellitus is a chronic illness manifested by improper blood glucose management, affecting over 350 million worldwide. As a result, all type 1 patients and roughly 20% of type 2 patients require exogenous insulin therapy to survive. Typically, daily multiple injections are taken to maintain normal glucose levels in response glucose spikes from meals. However, patient compliance and dosing accuracy can fluctuate with variation in meals, exercise, glucose metabolism or stress, leading to poor clinical outcomes. A 'smart', closed-loop insulin delivery system providing on-demand release kinetics responding to circulating glucose levels would be a boon for diabetes patients, replacing constant self monitoring and insulin. This thesis focuses on the development of a novel, 'smart' insulin microdevice that can provide on-demand insulin release in response to blood glucose levels. In the early stage, the feasibility of integrating a composite membrane with pH-responsive nanoparticles embedded in ethylcellulose membrane to provide pH-responsive in vitro release was examined and confirmed using a model drug, vitamin B12. In the second microdevice, glucose oxidase for generating pH signals from glucose oxidation, catalase and manganese dioxide nanoparticles, as peroxide scavengers, were used in a bioinorganic, albumin-based membrane cross-linked with a polydimethylsiloxane (PDMS) grid-microdevice system. This prototype device demonstrated insulin release in response to glucose levels in vitro and regulating plasma glucose in type 1 diabetic rats when implanted intraperitoneally. Advancement allowing for subcutaneous implantation and improved biocompatibility was achieved with surface modification of PDMS microdevices grafted with activated 20 kDa polyethylene glycol (PEG) chains, dramatically reducing immune response and local inflammation. When implanted subcutaneously in diabetic rats, glucose-responsive insulin delivery microdevices showed short and long

  17. Overweight, insulin resistance and type II diabetes in type I Gaucher disease patients in relation to enzyme replacement therapy

    NARCIS (Netherlands)

    Langeveld, M.; de Fost, M.; Aerts, J. M. F. G.; Sauerwein, H. P.; Hollak, C. E. M.

    2008-01-01

    Type I Gaucher disease, a lysosomal storage disorder is associated with metabolic abnormalities such as high resting energy expenditure, low circulating adiponectin and peripheral insulin resistance. Treatment with enzyme replacement therapy (enzyme therapy) leads to a decrease in resting energy

  18. Short-term oestrogen replacement therapy improves insulin resistance, lipids and fibrinolysis in postmenopausal women with NIDDM

    NARCIS (Netherlands)

    Brussaard, H.E.; Gevers Leuven, J.A.; Frölich, M.; Kluft, C.; Krans, H.M.J.

    1997-01-01

    Oestrogen replacement therapy is associated with a decreased risk of cardiovascular disease in postmenopausal women. Patients with non-insulin- dependent diabetes mellitus (NIDDM) have an increased cardiovascular risk. However, oestrogen replacement therapy is only reluctantly prescribed for

  19. Clearance of Hepatitis C Virus Improves Insulin Resistance During and After Peginterferon and Ribavirin Therapy.

    Science.gov (United States)

    Chien, Cheng-Hung; Lin, Chih-Lang; Hu, Ching-Chih; Chang, Jia-Jang; Chien, Rong-Nan

    2015-12-01

    Patients with chronic hepatitis C virus (HCV) infection are at a greater risk of developing insulin resistance (IR). However, little is known about when insulin sensitivity may improve during or after treatment for hepatitis C. In this study, we examined the effect of combination therapy with pegylated interferon-α and ribavirin on IR in patients with chronic HCV infection. We also analyzed factors associated with changes in insulin sensitivity. IR was estimated by homeostasis model assessment (HOMA-IR). HOMA-IR was measured before therapy, during therapy (12 and 24 weeks), and at the end of therapy (EOT; 24 or 48 weeks). We analyzed 78 HCV patients receiving combination therapy. Twenty-two patients (28.2%) exhibited pretreatment IR (HOMA-IR >2.5). In all patients, HOMA-IR was not significantly different from baseline values at 12 weeks (P = 0.823), 24 weeks (P = 0.417), or at EOT (P = 0.158). In patients with pretreatment IR, a significant decrease in HOMA-IR was observed at 12 weeks (P = 0.023), 24 weeks (P = 0.008), and at EOT (P = 0.002). Multivariate analysis using a logistic regression model showed that baseline HOMA-IR is the only factor associated with the decline in HOMA-IR during and after therapy. The eradication of HCV infection was associated with improved insulin sensitivity among patients with pretreatment IR. This significant improvement in insulin sensitivity may occur as early as 12 weeks after the initiation of antiviral therapy.

  20. Insulin therapy in patients with cystic fibrosis in the pre-diabetes stage: a systematic review.

    Science.gov (United States)

    Pu, Mariana Zorrón Mei Hsia; Christensen-Adad, Flávia Corrêa; Gonçalves, Aline Cristina; Minicucci, Walter José; Ribeiro, José Dirceu; Ribeiro, Antonio Fernando

    2016-09-01

    To elucidate whether insulin is effective or not in patients with cystic fibrosis before the diabetes mellitus phase. The study was performed according to the Prisma method between August and September 2014, using the PubMed, Embase, Lilacs and SciELO databases. Prospective studies published in English, Portuguese and Spanish from 2002 to 2014, evaluating the effect of insulin on weight parameters, body mass index and pulmonary function in patients with cystic fibrosis, with a mean age of 17.37 years before the diabetes mellitus phase were included. Eight articles were identified that included 180 patients undergoing insulin use. Sample size ranged from 4 to 54 patients, with a mean age ranging from 12.4 to 28 years. The type of follow-up, time of insulin use, the dose and implementation schedule were very heterogeneous between studies. There are theoretical reasons to believe that insulin has a beneficial effect in the studied population. The different methods and populations assessed in the studies do not allow us to state whether early insulin therapy should or should not be carried out in patients with cystic fibrosis prior to the diagnosis of diabetes. Therefore, studies with larger samples and insulin use standardization are required. Copyright © 2016 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  1. Insulin therapy in patients with cystic fibrosis in the pre-diabetes stage: a systematic review

    Directory of Open Access Journals (Sweden)

    Mariana Zorrón Mei Hsia Pu

    Full Text Available Abstract Objective: To elucidate whether insulin is effective or not in patients with cystic fibrosis before the diabetes mellitus phase. Data source: The study was performed according to the Prisma method between August and September 2014, using the PubMed, Embase, Lilacs and SciELO databases. Prospective studies published in English, Portuguese and Spanish from 2002 to 2014, evaluating the effect of insulin on weight parameters, body mass index and pulmonary function in patients with cystic fibrosis, with a mean age of 17.37 years before the diabetes mellitus phase were included. Data synthesis: Eight articles were identified that included 180 patients undergoing insulin use. Sample size ranged from 4 to 54 patients, with a mean age ranging from 12.4 to 28 years. The type of follow-up, time of insulin use, the dose and implementation schedule were very heterogeneous between studies. Conclusions: There are theoretical reasons to believe that insulin has a beneficial effect in the studied population. The different methods and populations assessed in the studies do not allow us to state whether early insulin therapy should or should not be carried out in patients with cystic fibrosis prior to the diagnosis of diabetes. Therefore, studies with larger samples and insulin use standardization are required.

  2. Long-term interdisciplinary therapy reduces endotoxin level and insulin resistance in obese adolescents.

    Science.gov (United States)

    Lira, Fábio S; Rosa, Jose C; Pimentel, Gustavo D; Santos, Ronaldo V; Carnier, June; Sanches, Priscila L; de Piano, Aline; de Souza, Claudio T; Tock, Lian; Tufik, Sergio; de Mello, Marco T; Seelaender, Marília; Oller do Nascimento, Claudia M; Oyama, Lila M; Dâmaso, Ana R

    2012-09-18

    The purpose of the present study was to assess the dietary fat intake, glucose, insulin, Homeostasis model assessment for insulin resistance HOMA-IR, and endotoxin levels and correlate them with adipokine serum concentrations in obese adolescents who had been admitted to long-term interdisciplinary weight-loss therapy. The present study was a longitudinal clinical intervention of interdisciplinary therapy. Adolescents (n = 18, aged 15-19 y) with a body mass index > 95th percentile were admitted and evaluated at baseline and again after 1 year of interdisciplinary therapy. We collected blood samples, and IL-6, adiponectin, and endotoxin concentrations were measured by ELISA. Food intake was measured using 3-day diet records. In addition, we assessed glucose and insulin levels as well as the homeostasis model assessment for insulin resistance (HOMA-IR). The most important finding from the present investigation was that the long-term interdisciplinary lifestyle therapy decreased dietary fat intake and endotoxin levels and improved HOMA-IR. We observed positive correlations between dietary fat intake and endotoxin levels, insulin levels, and the HOMA-IR. In addition, endotoxin levels showed positive correlations with IL-6 levels, insulin levels and the HOMA-IR. Interestingly, we observed a negative correlation between serum adiponectin and both dietary fat intake and endotoxin levels. The present results indicate an association between dietary fat intake and endotoxin level, which was highly correlated with a decreased pro-inflammatory state and an improvement in HOMA-IR. In addition, this benefits effect may be associated with an increased adiponectin level, which suggests that the interdisciplinary therapy was effective in improving inflammatory pathways.

  3. Long-term interdisciplinary therapy reduces endotoxin level and insulin resistance in obese adolescents

    Directory of Open Access Journals (Sweden)

    Lira Fábio S

    2012-09-01

    Full Text Available Abstract Aim The purpose of the present study was to assess the dietary fat intake, glucose, insulin, Homeostasis model assessment for insulin resistance HOMA-IR, and endotoxin levels and correlate them with adipokine serum concentrations in obese adolescents who had been admitted to long-term interdisciplinary weight-loss therapy. Design The present study was a longitudinal clinical intervention of interdisciplinary therapy. Adolescents (n = 18, aged 15–19 y with a body mass index > 95th percentile were admitted and evaluated at baseline and again after 1 year of interdisciplinary therapy. We collected blood samples, and IL-6, adiponectin, and endotoxin concentrations were measured by ELISA. Food intake was measured using 3-day diet records. In addition, we assessed glucose and insulin levels as well as the homeostasis model assessment for insulin resistance (HOMA-IR. Results The most important finding from the present investigation was that the long-term interdisciplinary lifestyle therapy decreased dietary fat intake and endotoxin levels and improved HOMA-IR. We observed positive correlations between dietary fat intake and endotoxin levels, insulin levels, and the HOMA-IR. In addition, endotoxin levels showed positive correlations with IL-6 levels, insulin levels and the HOMA-IR. Interestingly, we observed a negative correlation between serum adiponectin and both dietary fat intake and endotoxin levels. Conclusions The present results indicate an association between dietary fat intake and endotoxin level, which was highly correlated with a decreased pro-inflammatory state and an improvement in HOMA-IR. In addition, this benefits effect may be associated with an increased adiponectin level, which suggests that the interdisciplinary therapy was effective in improving inflammatory pathways.

  4. A Study of the Carbohydrate-to-Insulin Ratio in Pregnant Women with Type 1 Diabetes on Pump Treatment.

    Science.gov (United States)

    Bongiovanni, Marzia; Fresa, Raffaella; Visalli, Natalia; Bitterman, Olimpia; Suraci, Concetta; Napoli, Angela

    2016-06-01

    The aim of this study was to assess carbohydrate (CHO)-to-insulin ratio (CHO/IR) values in pregnant women with type 1 diabetes and to describe differences in CHO/IR across each week of pregnancy. This was a multicenter, retrospective, observational study (2006-2012) of 101 white pregnant women with a mean age of 32 (range, 18-43) years who had type 1 diabetes and were under continuous subcutaneous insulin infusion (CSII) therapy. These patients had the following characteristics: type 1 diabetes duration was 1 year (range, 1-31 years), the pregestational glycosylated hemoglobin level was 6.9% (range, 6.8-12.1%), the median weight gain during pregnancy was 14 kg (-3; 25 kg), with delivery at 37 weeks (range, 30-40 weeks), and the child had a birth weight of 3.530 kg (range, 1.480-5.250 kg). The CHO/IR was measured by dividing the CHO (in g) of each meal by insulin unit injected to acquire and maintain the following glycemic targets: fasting insulin and 300/total daily doses of insulin. Education and management before and during pregnancy were in agreement with Italian Association of Dietitians, Association of Medical Diabetologists, and Italian Society of Diabetology recommendations. Data were analyzed using SPSS software (version 20.0; SPSS, Inc., Chicago, IL). The CHO/IR decreased on average from 9.6 (5-18) to 5.4 (2.3-8) at breakfast, from 10 (3.5-16) to 8.4 (3.0-17.8) at lunch, and from 12.5 (8-20) to 6.1 (4.2-12) at dinner. The CHO/IR calculated using the "500 rule" decreased from 14.3 (10-20.3) to 8.6 (4.1-15.9). Using the "300 rule," the ratios decreased from 8.5 (6-12.1) to 5.2 (2.4-9.5). The bivariate correlation between the values calculated more appropriate values using the "300 rule" for breakfast and the "500 rule" for lunch and dinner across all weeks of pregnancy. CHO/IR reduction in pregnancy is likely due to an increase in insulin resistance.

  5. The effect of peer support in adults with insulin pump-treated type 1 diabetes: a pilot study of a flexible and participatory intervention

    Directory of Open Access Journals (Sweden)

    Joensen LE

    2017-11-01

    no need for peer support or felt that the group was not a unit or that important issues were not addressed. Conclusion: The study indicated that flexible and participatory peer support can strengthen diabetes-specific social capital and improve participants’ well-being and diabetes empowerment. Awareness of participants’ incentives for attending peer support, as well as the risk of people feeling isolated within peer support groups, is essential to creating effective diabetes-specific social support. Keywords: type 1 diabetes mellitus, insulin pump therapy, psychosocial support, psychological well-being, empowerment, exploratory research

  6. Role of Acid and Weakly Acidic Reflux in Gastroesophageal Reflux Disease Off Proton Pump Inhibitor Therapy

    OpenAIRE

    Sung, Hea Jung; Cho, Yu Kyung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-01-01

    Background/Aims Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. Methods We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. T...

  7. Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

    Science.gov (United States)

    Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal; Charpentier, Guillaume

    2014-11-01

    The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P pumps (-2.2 ± 5.6% vs -0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. © 2014 Diabetes Technology Society.

  8. Effect of metformin on plasma metabolite profile in the Copenhagen Insulin and Metformin Therapy (CIMT) trial

    DEFF Research Database (Denmark)

    Safai, N; Suvitaival, T; A, Ali

    2018-01-01

    of the Copenhagen Insulin and Metformin Therapy (CMIT) trial, a multicentre study from May 2008 to December 2012, was carried out. We used a non-target method to analyse 87 plasma metabolites in participants with Type 2 diabetes (n = 370) who were randomized in a 1 : 1 ratio to 18 months of metformin or placebo...

  9. Maternal insulin therapy does not restore foetoplacental endothelial dysfunction in gestational diabetes mellitus

    NARCIS (Netherlands)

    Subiabre, Mario; Silva, Luis; Villalobos-Labra, Roberto; Toledo, Fernando; Paublo, Mario; López, Marcia A.; Salsoso, Rocío; Pardo, Fabián; Leiva, Andrea; Sobrevia, Luis

    Pregnant women diagnosed with gestational diabetes mellitus subjected to diet (GDMd) that do not reach normal glycaemia are passed to insulin therapy (GDMi). GDMd associates with increased human cationic amino acid transporter 1 (hCAT-1)-mediated transport of L-arginine and nitric oxide synthase

  10. Determination of attitude and knowledge of type 2 diabetic patients towards insulin therapy in Northern Cyprus

    International Nuclear Information System (INIS)

    Yilmaz, U.D.; Tarhan, S.

    2017-01-01

    To determine the attitude and knowledge of type-2 diabetics related to insulin therapy. Methods: The descriptive cross-sectional study was conducted from January to March 2014 at the Dr. Burhan Nalbantoglu Public Hospital, Nicosia in the Turkish Republic of Northern Cyprus, and comprised patients with type-2 diabetes. The Likert scale was used to score participants' response to questions using the following scoring system: 0 (disagree), 1 (neutral) and 2 (agree). The minimum scoring value for all the questions combined was 0 whereas the maximum scoring value was 50. Patients' attitudes were classified as either high, medium or low based on scores between 0-16, 17-33 and 34-50, respectively. SPSS 16 was used for data analysis. Results: Of the 271 participants, 165(60.9%) were female and 106(39.1%) male. The overall mean age was 60.3+-32.4 years. Moreover, 136(50.3%) participants had a medium attitude and knowledge score towards insulin therapy. men scored significantly better than females (p<0.05). Only 25(9.2%) participants had a high score towards insulin therapy. Conclusion: The participants were found to have an inadequate attitude and knowledge response to insulin therapy. (author)

  11. Four-year evolution of insulin regimens, glycaemic control, hypoglycaemia and body weight after starting insulin therapy in type 2 diabetes across three continents.

    Science.gov (United States)

    Home, Philip D; Dain, Marie-Paule; Freemantle, Nick; Kawamori, Ryuzo; Pfohl, Martin; Brette, Sandrine; Pilorget, Valérie; Scherbaum, Werner A; Vespasiani, Giacomo; Vincent, Maya; Balkau, Beverley

    2015-05-01

    It is of interest to understand how insulin therapy currently evolves in clinical practice, in the years after starting insulin in people with type 2 diabetes. We aimed to describe this evolution prospectively over 4 years, to assist health care planning. People who had started any insulin were identified from 12 countries on three continents. Baseline, then yearly follow-up, data were extracted from clinical records over 4 years. Of the 2999 eligible people, 2272 were followed over 4 years. When starting insulin, mean (SD) duration of diabetes was 10.6 (7.8) years, HbA1c 9.5 (2.0)% (80 [22]mmol/mol) and BMI 29.3 (6.3)kg/m(2). Initial insulin therapy was basal 52%, premix 23%, mealtime+basal 14%, mealtime 8% and other 3%; at 4 years, 30%, 25%, 33%, 2% and 5%, respectively, with 5% not on insulin. Insulin dose was 20.2U/day at the start and 45.8U/day at year 4. There were 1258 people (55%) on their original regimen at 4 years, and this percentage differed according to baseline insulin regimen. HbA1c change was -2.0 (2.2)% (-22 [24]mmol/mol) and was similar by final insulin regimen. Hypoglycaemia prevalence was <20% in years 1-4. Body weight change was mostly in year 1, and was very variable, mean +2.7 (7.5)kg at year 4. Different insulin regimens were started in people with differing characteristics, and they evolved differently; insulin dose, hypoglycaemia and body weight change were diverse and largely independent of regimen. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  12. Exploring patients’ perceptions for insulin therapy in type 2 diabetes: a Brazilian and Canadian qualitative study

    Directory of Open Access Journals (Sweden)

    Camila Guimarães

    2010-06-01

    Full Text Available Camila Guimarães2, Carlo A Marra1, Sabrina Gill1, Graydon Meneilly1, Scot Simpson3, Ana LPC Godoy2, Maria Cristina Foss de Freitas2, Regina HC Queiroz2, Larry Lynd11The University of British Columbia, Canada; 2University of São Paulo, Brazil; 3The University of Alberta, CanadaObjective: To explore which attributes of insulin therapy drive patients’ preferences for management in Canada and Brazil.Methods: A qualitative design was implemented in which a total of 32 patients with type 2 diabetes from Canada and Brazil, were interviewed in one of the 4 focus groups, or 16 individual interviews. Eighteen participants (56% were women and fourteen participants (44% were men (15 insulin nonusers and 17 insulin users. Two focus groups of 4 participants each and 9 individual interviews were conducted in Brazil. In Canada, 2 focus groups of 4 participants each and 7 individual interviews were conducted. A framework analysis was used to analyse all data.Results: Brazilian participants, when considering two insulin treatments, would prefer the one that had fewer side-effects (specially hypoglycemia events, was noninjectable, had the lowest cost and was most effective. Meanwhile, Canadian participants would prefer a treatment that had fewer side-effects (specially weight gain, was less invasive, was more convenient and was most effective.Conclusions: Finding the insulin-delivery system and the attributes of insulin therapy that best meet patients’ preferences may lead to improved control, through improved compliance, which may ultimately reduce the financial burden of the disease and improve quality of life.Keywords: type 2 diabetes, insulin administration, glycemic control, weight gain, hypoglycemia, qualitative study, patients’ preferences

  13. SGLT2 inhibitors as adjunct therapy to insulin in type 1 diabetes: Meta analysis

    Directory of Open Access Journals (Sweden)

    Jiao CHEN

    2017-02-01

    Full Text Available Objective To evaluate the efficacy and safety of sodium glucose co-transporter-2 (SGLT-2 inhibitors as adjunct therapy to insulin in type 1 diabetes (T1DM. Methods The PubMed, The Cochrane Library, EMbase, CENTRRAI, CBM, CNKI, VIP and WangFang database were searched from inception to April 5, 2016 for systematic reviews, references screen was performed manually. The trials of SGLT2 inhibitors versus placebo add to insulin carried out in patients with T1DM were collected, and their bias risk was assessed and meta-analysis was conducted by using RevMan 5.3 software. Results Four randomized control trials (RCTs were yielded for meta-analysis, including 529 patients. Compared with control group, SGLT2 inhibitors as adjunct therapy to insulin significantly reduced fasting plasma glucose (FPG [weighted mean difference (WMD=–0.65mmol/L, 95% confidence interval (CI=–1.30 to –0.08, P<0.05], glycated hemoglobin A1C (HbA1c (WMD=–0.37%, 95%CI=–0.54 to –0.20, P<0.00001, body weight (WMD=–2.54kg, 95%CI=–3.48 to –1.60, P<0.0001 and total daily insulin dose (WMD=–6.23IU, 95% CI=–8.05 to –4.40, P<0.0001, but the total adverse events (AEs, hypoglycemia, genital and urinary infections showed no significant difference. Conclusions Based on current studies, SGLT-2 inhibitors are effective as adjunct therapy to insulin in T1DM, may improve glycemic control, reduce body weight and total daily insulin dose without increase of total AEs, hypoglycemia, and genital and urinary infections. DOI: 10.11855/j.issn.0577-7402.2016.12.15

  14. Insulin therapy refusal among type II diabetes mellitus patients in Kubang Pasu district, the state of Kedah, Malaysia.

    Science.gov (United States)

    Tan, Wei Leong; Asahar, Siti Fairus; Harun, Noor Liani

    2015-04-01

    Diabetes mellitus is a rising non-communicable disease in Malaysia. Insulin therapy refusal is a great challenge for healthcare providers, as it results in delayed insulin initiation. This study was conducted to determine the prevalence of insulin therapy refusal and its associated factors. This cross sectional study was conducted at seven public health clinics in Kubang Pasu district, Malaysia, from March to October 2012. A newly developed and validated questionnaire was used and participants were selected via systematic random sampling. Only patients diagnosed with type II diabetes mellitus (T2DM) and under the public health clinic care in Kubang Pasu were included in the study. Multiple logistic regressions were used to study the association between insulin therapy refusal and its associated factors. There were 461 respondents and the response rate was 100%. Among these 461 patients with T2DM, 74.2% refused insulin therapy. The most common reason given for refusal was a lack of confidence in insulin injection (85.4%). Multiple logistic regression revealed that respondents who had secondary education were 55.0% less likely to refuse insulin therapy than those who had primary or no formal education (p = 0.009, adjusted odds ratio [OR] = 0.45, 95% confidence interval [CI] = 0.25-0.82). There was also a significant inverse association between glycated haemoglobin (HbA1c) and insulin therapy refusal (p = 0.047, adjusted OR = 0.87, 95% CI = 0.76-1.00). Insulin therapy refusal is common in Kubang Pasu. Education status and HbA1c should be taken into consideration when counselling patients on insulin therapy initiation.

  15. Cortical thinning in type 2 diabetes mellitus and recovering effects of insulin therapy.

    Science.gov (United States)

    Chen, Zhiye; Sun, Jie; Yang, Yang; Lou, Xin; Wang, Yulin; Wang, Yan; Ma, Lin

    2015-02-01

    The purpose of this study was to explore the brain structural changes in type 2 diabetes and the effect of insulin on the brain using a surface-based cortical thickness analysis. High-resolution three-dimensional T1-weighted fast spoiled gradient recalled echo MRI were obtained from 11 patients with type 2 diabetes before and after insulin therapy. The cortical thickness over the entire brain was calculated, and cross-sectional and longitudinal surface-based cortical thickness analyses were also performed. Regional cortical thinning was demonstrated in the middle temporal gyrus, posterior cingulate gyrus, precuneus, right lateral occipital gyrus and entorhinal cortex bilaterally for patients with type 2 diabetes mellitus compared with normal controls. Cortical thickening was seen in the middle temporal gyrus, entorhinal cortex and left inferior temporal gyrus bilaterally after patients underwent 1 year of insulin therapy. These findings suggest that insulin therapy may have recovering effects on the brain cortex in type 2 diabetes mellitus. The precise mechanism should be investigated further. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Insulin therapy waste produced in the households of people with diabetes monitored in Primary Care

    Directory of Open Access Journals (Sweden)

    Gilmara Holanda da Cunha

    Full Text Available ABSTRACT Objective: To analyze the insulin therapy waste disposal produced in the households of people with diabetes mellitus (DM. Method: Cross-sectional study with 105 Primary Care patients. Socio-demographic and clinical variables and insulin therapy practice were analyzed through the absolute and relative frequencies, Fisher's exact test and prevalence ratio (PR. Results: The association between types of insulin (60.0%, administered with a disposable syringe attached to a needle (80.9%, and a high percentage of reuse and disposal in normal household waste (57.1% stood out. The professionals who most frequently provided guidance to people with diabetes were the nurses. Patients who had received instructions about disposal were 21 times more likely to dispose of waste properly than those who had not (PR 21.5; P 0.05. Conclusion: People with diabetes served in Primary Health Care require guidance and material resources to carry out the appropriate disposal of insulin therapy waste.

  17. Cost-effectiveness of insulin pumps compared with multiple daily injections both provided with structured education for adults with type 1 diabetes: a health economic analysis of the Relative Effectiveness of Pumps over Structured Education (REPOSE) randomised controlled trial.

    Science.gov (United States)

    Pollard, Daniel John; Brennan, Alan; Dixon, Simon; Waugh, Norman; Elliott, Jackie; Heller, Simon; Lee, Ellen; Campbell, Michael; Basarir, Hasan; White, David

    2018-04-07

    To assess the long-term cost-effectiveness of insulin pumps and Dose Adjustment for Normal Eating (pumps+DAFNE) compared with multiple daily insulin injections and DAFNE (MDI+DAFNE) for adults with type 1 diabetes mellitus (T1DM) in the UK. We undertook a cost-utility analysis using the Sheffield Type 1 Diabetes Policy Model and data from the Relative Effectiveness of Pumps over Structured Education (REPOSE) trial to estimate the lifetime incidence of diabetic complications, intervention-based resource use and associated effects on costs and quality-adjusted life years (QALYs). All economic analyses took a National Health Service and personal social services perspective and discounted costs and QALYs at 3.5% per annum. A probabilistic sensitivity analysis was performed on the base case. Further uncertainties in the cost of pumps and the evidence used to inform the model were explored using scenario analyses. Eight diabetes centres in England and Scotland. Adults with T1DM who were eligible to receive a structured education course and did not have a strong clinical indication or a preference for a pump. Pumps+DAFNE. MDI+DAFNE. Incremental costs, incremental QALYs gained and incremental cost-effectiveness ratios (ICERs). Compared with MDI+DAFNE, pumps+DAFNE was associated with an incremental discounted lifetime cost of +£18 853 (95% CI £6175 to £31 645) and a gain in discounted lifetime QALYs of +0.13 (95% CI -0.70 to +0.96). The base case mean ICER was £142 195 per QALY gained. The probability of pump+DAFNE being cost-effective using a cost-effectiveness threshold of £20 000 per QALY gained was 14.0%. All scenario and subgroup analyses examined indicated that the ICER was unlikely to fall below £30 000 per QALY gained. Our analysis of the REPOSE data suggests that routine use of pumps in adults without an immediate clinical need for a pump, as identified by National Institute for Health and Care Excellence, would not be cost-effective. ISRCTN61215213

  18. β3-Adrenoceptor activation relieves oxidative inhibition of the cardiac Na+-K+ pump in hyperglycemia induced by insulin receptor blockade.

    Science.gov (United States)

    Karimi Galougahi, Keyvan; Liu, Chia-Chi; Garcia, Alvaro; Fry, Natasha A; Hamilton, Elisha J; Figtree, Gemma A; Rasmussen, Helge H

    2015-09-01

    Dysregulated nitric oxide (NO)- and superoxide (O2 (·-))-dependent signaling contributes to the pathobiology of diabetes-induced cardiovascular complications. We examined if stimulation of β3-adrenergic receptors (β3-ARs), coupled to endothelial NO synthase (eNOS) activation, relieves oxidative inhibition of eNOS and the Na(+)-K(+) pump induced by hyperglycemia. Hyperglycemia was established in male New Zealand White rabbits by infusion of the insulin receptor antagonist S961 for 7 days. Hyperglycemia increased tissue and blood indexes of oxidative stress. It induced glutathionylation of the Na(+)-K(+) pump β1-subunit in cardiac myocytes, an oxidative modification causing pump inhibition, and reduced the electrogenic pump current in voltage-clamped myocytes. Hyperglycemia also increased glutathionylation of eNOS, which causes its uncoupling, and increased coimmunoprecipitation of cytosolic p47(phox) and membranous p22(phox) NADPH oxidase subunits, consistent with NADPH oxidase activation. Blocking translocation of p47(phox) to p22(phox) with the gp91ds-tat peptide in cardiac myocytes ex vivo abolished the hyperglycemia-induced increase in glutathionylation of the Na(+)-K(+) pump β1-subunit and decrease in pump current. In vivo treatment with the β3-AR agonist CL316243 for 3 days eliminated the increase in indexes of oxidative stress, decreased coimmunoprecipitation of p22(phox) with p47(phox), abolished the hyperglycemia-induced increase in glutathionylation of eNOS and the Na(+)-K(+) pump β1-subunit, and abolished the decrease in pump current. CL316243 also increased coimmunoprecipitation of glutaredoxin-1 with the Na(+)-K(+) pump β1-subunit, which may reflect facilitation of deglutathionylation. In vivo β3-AR activation relieves oxidative inhibition of key cardiac myocyte proteins in hyperglycemia and may be effective in targeting the deleterious cardiac effects of diabetes. Copyright © 2015 the American Physiological Society.

  19. Personality variables and compliance with insulin therapy in Type 2 diabetic subjects.

    Science.gov (United States)

    Gentili, P; Maldonato, A; Bloise, D; Burla, F; Coronel, G; Di Paolantonio, T

    2000-02-01

    Forty-five diabetic patients were studied to evaluate adaptation and coping strategies. The authors have also analysed personality traits mainly to study different behaviour in compliance conduct. The results revealed an important psychological dimension made up of difficulties in accepting insulin immediately, in fear of addiction and doubts about the therapy. On the basis of these results the sample was then divided into two subgroups, which were then tested and compared with the Adjective Check List. The subgroup that showed more fear, insecurity and initial resistance towards insulin therapy appeared to be more rigid and seemingly conforming. These people also revealed personality aspects compatible with the presence of passive-aggressive and avoidant traits.

  20. The Role of Insulin Therapy in Correcting Hepcidin Levels in Patients with Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Driton Vela

    2017-05-01

    Full Text Available Objectives: Iron overload can cause or contribute to the pathogenesis of type 2 diabetes mellitus (T2DM, but how the major parameters of iron metabolism change in different settings of diabetes are still unclear. The aim of this study was to determine the relationship between iron, ferritin, and hepcidin levels in diabetic patients and the effect of insulin treatment. Methods: The study included 80 subjects, 60 with T2DM and 20 without (control group. Serum hepcidin, insulin, ferritin, and iron levels were determined as well as other clinical parameters. The associations between these parameters were analyzed between both groups. Results: Hepcidin levels expressed as mean± standard deviation between groups showed no significant changes (14.4±6.7 ng/mL for the control group, and 18.4±7.9 ng/mL for patients with diabetes, p = 0.069. Parameters of iron metabolism showed modest correlation with the parameters of glucose metabolism. However, the correlation between ferritin and insulin in both groups was statistically significant (p = 0.032; ρ = 0.480 vs. p = 0.011; ρ = 0.328. Conclusions: Our study showed that hepcidin levels in patients with T2DM on insulin therapy do not change, which might be a result of treatment with insulin. In this context, insulin treatment can be used as a novel method for correction of hepcidin levels. By correcting hepcidin levels, we can prevent cellular iron overload and reduce the risk of diabetes.

  1. Effects of medical therapy on insulin resistance and the cardiovascular system in polycystic ovary syndrome.

    Science.gov (United States)

    Meyer, Caroline; McGrath, Barry P; Teede, Helena Jane

    2007-03-01

    We aimed to determine the impact of medical therapy for symptom management on insulin resistance, metabolic profiles, and surrogate markers of cardiovascular disease in polycystic ovary syndrome (PCOS), an insulin-resistant pre-diabetes condition. One hundred overweight women (BMI >27 kg/m2), average age 31 years, who were nonsmokers, were not pregnant, did not have diabetes, and were off relevant medications for 3 months completed this 6-month open-label controlled trial. Randomization was to a control group (higher-dose oral contraceptive [OCP] 35 microg ethinyl estradiol [EE]/2 mg cyproterone acetate, metformin [1 g b.d.] or low-dose OCP [20 microg EE/100 microg levonorgestrel + aldactone 50 mg b.d.]). Primary outcome measures were insulin resistance (area under curve on oral glucose tolerance test) and surrogate markers of cardiovascular disease including arterial stiffness (pulse wave velocity [PWV]) and endothelial function. All treatments similarly and significantly improved symptoms including hirsutism and menstrual cycle length. Insulin resistance was improved by metformin and worsened by the high-dose OCP. Arterial stiffness worsened in the higher-dose OCP group (PWV 7.46 vs. 8.03 m/s, P insulin resistance. In overweight women with PCOS, metformin and low- and high-dose OCP preparations have similar efficacy but differential effects on insulin resistance and arterial function. These findings suggest that a low-dose OCP preparation may be preferable if contraception is needed and that metformin should be considered for symptomatic management, particularly in women with additional metabolic and cardiovascular risk factors.

  2. Proton pump inhibitor step-down therapy for GERD: A multi-center study in Japan

    Science.gov (United States)

    Tsuzuki, Takao; Okada, Hiroyuki; Kawahara, Yoshiro; Takenaka, Ryuta; Nasu, Junichiro; Ishioka, Hidehiko; Fujiwara, Akiko; Yoshinaga, Fumiya; Yamamoto, Kazuhide

    2011-01-01

    AIM: To investigate the predictors of success in step-down of proton pump inhibitor and to assess the quality of life (QOL). METHODS: Patients who had heartburn twice a week or more were treated with 20 mg omeprazole (OPZ) once daily for 8 wk as an initial therapy (study 1). Patients whose heartburn decreased to once a week or less at the end of the initial therapy were enrolled in study 2 and treated with 10 mg OPZ as maintenance therapy for an additional 6 mo (study 2). QOL was investigated using the gastrointestinal symptom rating scale (GSRS) before initial therapy, after both 4 and 8 wk of initial therapy, and at 1, 2, 3, and 6 mo after starting maintenance therapy. RESULTS: In study 1, 108 patients were analyzed. Their characteristics were as follows; median age: 63 (range: 20-88) years, sex: 46 women and 62 men. The success rate of the initial therapy was 76%. In the patients with successful initial therapy, abdominal pain, indigestion and reflux GSRS scores were improved. In study 2, 83 patients were analyzed. Seventy of 83 patients completed the study 2 protocol. In the per-protocol analysis, 80% of 70 patients were successful for step-down. On multivariate analysis of baseline demographic data and clinical information, no previous treatment for gastroesophageal reflux disease (GERD) [odds ratio (OR) 0.255, 95% CI: 0.06-0.98] and a lower indigestion score in GSRS at the beginning of step-down therapy (OR 0.214, 95% CI: 0.06-0.73) were found to be the predictors of successful step-down therapy. The improved GSRS scores by initial therapy were maintained through the step-down therapy. CONCLUSION: OPZ was effective for most GERD patients. However, those who have had previous treatment for GERD and experience dyspepsia before step-down require particular monitoring for relapse. PMID:21472108

  3. Brain expansion in patients with type II diabetes following insulin therapy: a preliminary study with longitudinal voxel-based morphometry.

    Science.gov (United States)

    Chen, Zhiye; Li, Jinfeng; Sun, Jie; Ma, Lin

    2014-01-01

    We performed a longitudinal analysis based on magnetic resonance (MR) imaging to investigate the brain structural and perfusion changes caused by insulin therapy in patients with type II diabetes. High resolution three-dimensional T1-weighted fast spoiled gradient recalled echo images and flow-sensitive alternating inversion recovery (FAIR) images were obtained from 11 patients with type II diabetes before and 1 year after initiation of insulin therapy and 11 normal controls. Brain volume changes were investigated by a longitudinal voxel-based morphometry (VBM), and perfusion changes were evaluated by FAIR imaging between baseline and follow-up data. Significant regional gray matter (GM) expansion located in bilateral frontal, parietal, and left occipital lobes, and regional white matter (WM) expansion was shown in left precentral subcortical WM and right angular subcortical WM after insulin therapy (P Brain hyperperfusion was detected in bilateral frontal cortex, left occipital cortex, and right temporal cortex after insulin therapy (P brain expansion and hyperperfusion were demonstrated 1 year after initiation of insulin therapy, and insulin therapy could contribute to the brain volume gainment in the patients with type II diabetes. Copyright © 2013 by the American Society of Neuroimaging.

  4. Application of 3C insulin pump system in combination with non-invasive ventilation in the treatment of a patient with type 2 diabetes and obstructive sleep apnea syndrome.

    Science.gov (United States)

    Dong, Peng; Xu, Jing; Wang, Junhong; Zhang, Chunhong

    2018-03-01

    We observed the curative effect of the 3C insulin system in combination with non-invasive ventilation in a patient with type 2 diabetes and obstructive sleep apnea syndrome (OSAS). The 3C insulin pump is a system of devices that closely monitors and effectively regulates blood glucose levels. Non-invasive ventilation has been shown to be an effective treatment for OSAS. A type 2 diabetes patient with concomitant OSAS was treated with a 3C insulin pump system for real-time continuous glucose monitoring and nocturnal non-invasive ventilation for OSAS. Treatment-induced diabetic remission with improved sleep and reduced hypoglycemic episodes was achieved. Therefore, the 3C insulin pump system, in combination with non-invasive ventilation, is an effective treatment for type 2 diabetes patients with concomitant OSAS. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  5. Influence of insulin therapy on circulating ghrelin and insulin-like ghrelinowth factor-1(IGF-1) levels in children with type-1 diabetes mellitus

    International Nuclear Information System (INIS)

    Moawad, A.T.; Nassar, E.M.; Mostafa, A.M.; Mohammed, S.K.

    2009-01-01

    Diabetes mellitus type 1 (IDDM)is a chronic disease associated with alterations in the growth hormone/insulin -like growth factor (GH-IGF) system and ghrelin level which may lead to changes in metabolic control. This study aimed to evaluate the circulating levels of the gut-derived peptides (ghrelin and insulin-like growth factors (IGF s ) in children with IDDM and to link these two peptides with the glucose level in diabetic children at diagnoses and after insulin therapy. Design and methods: the studied group consisted of 30 newly diagnosed diabetic children (17 females and 13 males) diagnosed in paediatric diabetes unit, children's hospital, Ain shams university. Their age ranged from (6.2-11.8) years with mean of 10.10± 1.74 years. Twenty non diabetic healthy children matching in age and sex served as controls. Serum ghrelin was determined by enzyme linked immuno absorbanet assay (ELISA), while IGF-1 and insulin-like growth factors binding proteins -1 and 3 (IGFBP s ) were assessed by radioimmunoassay(RIA). Results: body mass index (BMI) in patients was significantly decreased in the diabetic group as compared to the healthy group at diagnosis. After insulin therapy BMI was significantly increase as compared to its value at diagnosis (p< 0.05) such increase was not significant on comparing to controls. Regarding blood glucose level there was very highly significant decrease in the level of HBAI (glycolated HB) in diabetic patients after insulin therapy (p<0.0001) than at diagnosis . The mean ghrelin level was highly significantly decreased in diabetic children at diagnosis and after insulin therapy as compared to controls (p<0.0001). No differences were found in the mean ghrelin levels in diabetic children at diagnosis or after insulin therapy.conclusions : the decrease in mean gherlin levels in this study at diagnosis and after therapy could reflect an attempt by the body to decrease the glucose level and thus may prevent hyperglycemia in diabetic patients

  6. Impact of targeted education on managing warning and error signals by children and adolescents with type 1 diabetes using the Accu-Chek Combo Insulin Pump System

    Directory of Open Access Journals (Sweden)

    Asma Deeb

    2017-09-01

    Full Text Available Purpose Insulin pumps are widely used in diabetes. They are equipped with safety alarms to alert users. Pump manuals contain alarm codes and how to troubleshoot them. However, these manuals are lengthy and difficult to use, particularly in emergencies. We aim to assess the impact of targeted education on warnings and errors in improving competency to troubleshoot the alarms. Methods Twenty-one patients, with a median age of 13, were recruited over a 5-month period. Each patient had 2 study visits. The frequencies and types of alarms were recorded, and patients were given a summary sheet that outlined common alarms encountered and troubleshooting tips. In visit 2, the frequencies and types of alarms were compared to those of visit 1. The patients were asked to fill a questionnaire and to rate the education session given in visit 1, their level of competency in decrypting alarm codes, and their promptness in responding to alarms. Results Low cartridge (W1, low battery (W2, and bolus cancelled (W8 were the commonest warnings. The most noted errors were occlusion (E4, power interruption (E8, empty battery (E2, set not primed (E11, and cartridge empty (E1. The numbers of warning and error signals markedly decreased after targeted education (P<0.05. The ability in decrypting warning signals significantly improved (P=0.02, and the frequency of response to pump alarms significantly increased (P=0.001. Conclusions Certain warnings and errors are more common than others in insulin pumps. Targeted education is useful in improving competency and response of patients in managing pump alarms.

  7. Improvement of insulin secretion in rat models of diabetes after ACEI/ARB therapy

    International Nuclear Information System (INIS)

    Tian Jingyan; Li Fengying; Liu Yun; Long Hongmei; Li Weiyi; Wang Xiao; Zhang Hongli; Li Guo; Luo Min

    2009-01-01

    Objective To study the effect of ACEI/ARB therapy on the secretion of insulin and glucagon as well as serum lipid peroxidation marker 8-iso PGF-2α levels in streptozoticin (STZ) induced diabetic rat models.Methods Twenty-four rat models of STZ induced diabetes were prepared (random blood sugar>16.7 mmol/L). Of which, 8 models were fed enalaprial 5mg/kg/d, 8 models were fed losartan 10μg/kg/d and 8 models left unterated. Fasting serum insulin,glucagon (with RIA) and 8-iso PGF-2α (with ELISA) levels were measured in these models and 8 control rats three weeks later. Intravenous glucose tolerance test (IVGTT) were performed in 12 rats (3 animals in each group) six weeks later. Results: Serum levels of insulin in the treated models were higher than those in the non-treated models but without significance (P>0.05). Serum levels of glucagon and 8-iso PGF-2α levels in the treated models were significantly lower than those in the non-treated models (P 6 x ) in the treated models. Conclusion: ACEI/ARB treatment could improve the secretion of insulin in rat models of diabetes, which might be beneficial for controlling the progression of the disease. This phenomenon is consistent with the result of clinical study. (authors)

  8. Adherence to Basal Insulin Therapy Among People with Type 2 Diabetes: A Retrospective Cohort Study of Costs and Patient Outcomes.

    Science.gov (United States)

    Perez-Nieves, Magaly; Boye, Kristina S; Kiljanski, Jacek; Cao, Dachung; Lage, Maureen J

    2018-04-11

    This research compares costs, resource utilization, and complications between adherent and nonadherent patients over the 3-year period post initiation on basal insulin therapy. The study utilized the US-based Truven Health MarketScan ® Research Databases from 2011 through 2015. Adults aged 18 years or older and identified with type 2 diabetes (T2D) who initiated therapy on basal insulin in 2012 were included. Patients were excluded if they were pregnant, filled their index basal insulin prescription via mail order, or were not continuously insured from 1 year before through 3 years following initiation of treatment with basal insulin. Instrumental variables were used to control for selection bias, and multivariable analyses were used to examine the associations between adherence to basal insulin therapy and costs, resource utilization, and acute complications. A total of 21,363 individuals were included in the study. Three years after initiating therapy on basal insulin, patients who were adherent over time to basal insulin treatment therapy (33.8% of patients) had significantly higher diabetes-related drug costs. However, patients' adherence was associated with significantly lower diabetes-related outpatient, acute care, and total costs. Results for all-cause costs were similar. Adherent patients also had significantly fewer all-cause and diabetes-related hospitalizations and emergency room visits and were significantly less likely to be diagnosed with an acute complication. Results of this study illustrate that despite higher drug costs, there are disease-specific and all-cause cost offsets and improved patient outcomes associated with adherence to basal insulin therapy for people with T2D. Eli Lilly and Company.

  9. Development of a booklet on insulin therapy for children with diabetes mellitus type 1.

    Science.gov (United States)

    Moura, Denizielle de Jesus Moreira; Moura, Nádya Dos Santos; Menezes, Luciana Catunda Gomes de; Barros, Ariane Alves; Guedes, Maria Vilani Cavalcante

    2017-01-01

    to describe the process of developing of an educational booklet on insulin therapy for children with diabetes mellitus type 1. methodological approach, in which the following steps were carried out: selecting of the content and type of technology to be developed (for this step, an integrative review, an analysis of the comments of blogs about Diabetes Mellitus type 1 and interviews with the children were performed), creation of images, formatting and layout composition. the work resulted in the production of the final version of the educational booklet, which was titled Aplicando a insulina: a aventura de Beto [Applying insulin: Beto's adventure]. The process of developing of the booklet was based on the active participation of the children and guided by the theoretical framework of Piagetian Constructivism. the resource is a facilitator for the improvement of the knowledge and practices of self care of children with Diabetes Mellitus type 1.

  10. [The optimal blood glucose target in critically ill patient: comparison of two intensive insulin therapy protocols].

    Science.gov (United States)

    Raurell Torredà, Marta; del Llano Serrano, César; Almirall Solsona, Dolors; Catalan Ibars, Rosa María; Nicolás Arfelis, José María

    2014-03-04

    Recent studies in critically ill patients receiving insulin intravenous therapy (IIT) have shown an increased incidence of severe hypoglycemia, while intermittent subcutaneous insulin «sliding scales» (conventional insulin therapy [CIT]) is associated with hyperglycemia. The objective of this study is to assess whether glycemic control range IIT can affect glucose levels and their variability and to compare it with CIT. Prospective comparative cohort study in intensive care unit, with 2 study periods: Period 1, IIT with glycemic target range 110-140 mg/dL, and Period 2, IIT of 140-180 mg/dL. In both periods CIT glycemic target was 110-180 mg/dL. We assessed severe hypoglycemia ( 216 mg/L) and the variability of blood glucose. We studied 221 patients with 12.825 blood glucose determinations. Twenty-six and 17% of patients required IIT for glycemic control in Period 1 and 2, respectively. Hypoglycemia was associated with a discontinuous nutritional intake, glycemic target 110-140 mg/dL and low body mass index (BMI) (P = .002). Hyperglycemia was exclusively associated with a history of diabetes mellitus (OR 2.6 [95% CI 1.6 to 4.5]). Glycemic variability was associated with a discontinuous nutritional intake, low BMI, CIT insulinization, diabetes mellitus, elderly and high APACHE II (P < .001). The use of IIT is useful to reduce the variability of blood glucose. Although the 140-180 mg/dL range would be more secure as to presenting greater variability and hyperglycemia, the 110-140 mg/dL range is most suitable. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  11. Performing a cure for schizophrenia: insulin coma therapy on the wards.

    Science.gov (United States)

    Doroshow, Deborah Blythe

    2007-04-01

    Most historians of psychiatry regard insulin coma therapy (ICT) either as an embarrassing stumble on the path to modern biological psychiatry or as one member of a long line of somatic therapies used to treat mental illness in the mid-twentieth century. This article explores the ICT era, roughly 1933-60, as a key moment in the development of American psychiatry. Developed only ten years after insulin had been embraced as a "miracle drug" for the treatment of diabetes, ICT was perceived by psychiatrists as a means of bringing their field closer to mainstream medicine, particularly to neurology. In addition, the story of ICT reveals how a treatment never quite proven on paper was unquestionably efficacious in the local world in which it was performed. An institutionally-based treatment, ICT was administered in a specific area of the mental hospital deemed the insulin unit, a room with its own staff, practices, and attitudes toward mental illness. There, psychiatrists often experienced wondrous recoveries of individual, formerly intractable patients. These intense personal experiences allowed psychiatrists to feel truly efficacious, enabling them to reinvent themselves as medical doctors rather than behavioral and disciplinary supervisors. The confidence they derived from this capacity, along with the operating room-like setting of the insulin unit, the unit's specialized staffing and group bond, and the availability of both risk-assessment tests and a medley of treatments that countered side effects and complications, allowed ICT to be understood as an efficacious treatment for schizophrenia within the local world in which it was administered.

  12. Are late-night eating habits and sleep duration associated with glycemic control in adult type 1 diabetes patients treated with insulin pumps?

    Science.gov (United States)

    Matejko, Bartlomiej; Kiec-Wilk, Beata; Szopa, Magdalena; Trznadel Morawska, Iwona; Malecki, Maciej T; Klupa, Tomasz

    2015-07-01

    Little is known about the impact of sleep duration and late-night snacking on glycemic control in patients with type 1 diabetes using insulin pumps. The aim of the present study was to examine whether late-night eating habits and short sleep duration are associated with glycemic control in continuous subcutaneous insulin infusion-treated type 1 diabetic patients. We included 148 consecutive adult type 1 diabetic subjects using an insulin pump (100 women and 48 men). Participants completed a questionnaire regarding sleep duration (classified as short if ≤6 h) and late-night snacking. Other sources of information included medical records and data from blood glucose meters. Glycemic control was assessed by glycated hemoglobin (HbA1c) levels and mean self-monitoring of blood glucose (SMBG) readings. The mean age of patients was 26 years, mean type 1 diabetes duration was 13.4 years and mean HbA1c level was 7.2%. In a univariate regression analysis, sleep duration was a predictor of both HbA1c (β = 0.51, P = 0.01) and SMBG levels (β = 11.4, P = 0.02). Additionally, an association was found between frequent late-night snacking and higher SMBG readings (often snacking β = 18.1, P = 0.05), but not with increased HbA1c levels. In the multivariate linear regression, independent predictors for HbA1c and SMBG were sleep duration and patient age. In a univariate logistic regression, sleep duration and frequency of late-night snacking were not predictors of whether HbA1c target levels were achieved. Short sleep duration, but not late-night snacking, seems to be associated with poorer glycemic control in type 1 diabetic patients treated with continuous subcutaneous insulin infusion.

  13. Prolonged Treatment Duration is Required for Successful Helicobacter pylori Eradication with Proton Pump Inhibitor Triple Therapy in Canada

    Directory of Open Access Journals (Sweden)

    Carlo A Fallone

    2013-01-01

    Full Text Available BACKGROUND: Traditional seven-day proton pump inhibitor triple therapy for Helicobacter pylori eradication has recently shown disappointing results outside of Canada. Prolonging therapy may be associated with poorer compliance and, hence, may not have a better outcome in a real-world setting.

  14. Epidemiological characterization of diabetic patients on therapy with continuous subcutaneous insulin infusion and continuous glucose monitoring in real time.

    Science.gov (United States)

    Aristizábal, Natalia; Ramírez, Alex; Hincapié-García, Jaime; Laiton, Estefany; Aristizábal, Carolina; Cuesta, Diana; Monsalve, Claudia; Hincapié, Gloria; Zapata, Eliana; Abad, Verónica; Delgado, Maria-Rocio; Torres, José-Luis; Palacio, Andrés; Botero, José

    2015-11-01

    To describe baseline characteristics of diabetic patients who were started on insulin pump and real time continuous glucose monitor (CSII-rtCGM) in a specialized center in Medellin, Colombia. All patients with diabetes with complete data who were started on CSII-rtCGM between February 2010 and May 2014 were included. This is a descriptive analysis of the sociodemographic and clinical characteristics. 141 of 174 patients attending the clinic were included. 90,1% had type 1diabetes (T1D). The average age of T1D patients at the beginning of therapy was 31,4 years (SD 14,1). 75.8% of patients had normal weight (BMI30). The median duration of T1D was 13 years (P25-P75=10.7-22.0). 14,2% of the patients were admitted at least once in the year preceding the start of CSII-rtCGM because of diabetes related complications. Mean A1c was 8.6%±1.46%. The main reasons for starting CSII-rtCGM were: poor glycemic control (50.2%); frequent hypoglycemia, nocturnal hypoglycemia, hypoglycemia related to exercise, asymptomatic hypoglycemia (30.2%); severe hypoglycemia (16.44%) and dawn phenomena (3.1%). Baseline characteristics of patients included in this study who were started on CSII-rtCGM are similar to those reported in the literature. The Clinic starts CSII-rtCGM mainly in T1D patients with poor glycemic control, frequent or severe hypoglycemia despite being on basal/bolus therapy. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  15. Proton pump inhibitors therapy vs H2 receptor antagonists therapy for upper gastrointestinal bleeding after endoscopy: A meta-analysis.

    Science.gov (United States)

    Zhang, Ying-Shi; Li, Qing; He, Bo-Sai; Liu, Ran; Li, Zuo-Jing

    2015-05-28

    To compare the therapeutic effects of proton pump inhibitors vs H₂ receptor antagonists for upper gastrointestinal bleeding in patients after successful endoscopy. We searched the Cochrane library, MEDLINE, EMBASE and PubMed for randomized controlled trials until July 2014 for this study. The risk of bias was evaluated by the Cochrane Collaboration's tool and all of the studies had acceptable quality. The main outcomes included mortality, re-bleeding, received surgery rate, blood transfusion units and hospital stay time. These outcomes were estimated using odds ratios (OR) and mean difference with 95% confidence interval (CI). RevMan 5.3.3 software and Stata 12.0 software were used for data analyses. Ten randomized controlled trials involving 1283 patients were included in this review; 678 subjects were in the proton pump inhibitors (PPI) group and the remaining 605 subjects were in the H₂ receptor antagonists (H₂RA) group. The meta-analysis results revealed that after successful endoscopic therapy, compared with H₂RA, PPI therapy had statistically significantly decreased the recurrent bleeding rate (OR = 0.36; 95%CI: 0.25-0.51) and receiving surgery rate (OR = 0.29; 95%CI: 0.09-0.96). There were no statistically significant differences in mortality (OR = 0.46; 95%CI: 0.17-1.23). However, significant heterogeneity was present in both the numbers of patients requiring blood transfusion after treatment [weighted mean difference (WMD), -0.70 unit; 95%CI: -1.64 - 0.25] and the time that patients remained hospitalized [WMD, -0.77 d; 95%CI: -1.87 - 0.34]. The Begg's test (P = 0.283) and Egger's test (P = 0.339) demonstrated that there was no publication bias in our meta-analysis. In patients with upper gastrointestinal bleeding after successful endoscopic therapy, compared with H₂RA, PPI may be a more effective therapy.

  16. Novas opções na terapia insulínica New options in insulin therapy

    Directory of Open Access Journals (Sweden)

    Helena Schmid

    2007-11-01

    Full Text Available OBJETIVO: Revisar as novas opções nas terapêuticas insulínicas para controlar o diabetes melito de crianças e adolescentes. FONTES DOS DADOS: Foram revisados artigos indexados no PubMed buscados conforme as palavras insulin analogs in children and adolescents e incluídas informações contidas nos consensos da American Diabetes Association e Sociedade Brasileira de Diabetes. SÍNTESE DOS DADOS: São apresentadas informações sobre os novos análogos da insulina e, para comparação, são também revisadas as outras diferentes modalidades de insulina que estão atualmente disponíveis, focalizando nas terapias insulínicas que tentam fornecer uma aproximação mais fisiológica das estratégias basal-bolos no tratamento. Com o objetivo de obter melhor controle metabólico, mais e mais crianças estão em regimes de múltiplas injeções diárias ou usando infusões subcutâneas contínuas de insulina. Atingir controle glicêmico ótimo nas crianças é difícil devido ao maior risco de hipoglicemia decorrente da grande variabilidade em hábitos de ingerir alimentos e em níveis de atividade física. Se aplicados em bolos, subcutâneos, no diabetes tipo 1, os análogos de ação rápida, comparados com insulina humana regular, geralmente reduzem os episódios de hipoglicemia e glicemia pós-prandial, enquanto os análogos basais tendem a reduzir particularmente a hipoglicemia noturna. CONCLUSÃO: Embora os benefícios nos desfechos individuais metabólicos e clínicos pareçam modestos, a maioria dos estudos demonstra benefícios quando são usados análogos de insulina no tratamento do diabetes tipo 1 ou 2.OBJECTIVE:To review the new options in insulin therapy for controlling diabetes mellitus in children and adolescents. SOURCES: Articles indexed in PubMed were located using the search terms insulin analogs in children and adolescents and reviewed. Information was also obtained from American Diabetes Association and Sociedade Brasileira

  17. Quality of life and impact of continuous subcutaneous insulin infusion for children and their parents

    DEFF Research Database (Denmark)

    Barnard, Katharine D.; Speight, Jane; Skinner, T. Chas

    2008-01-01

    This study aimed to identify key components of quality of life (QoL) and assess the impact of insulin pump therapy on children/adolescents with type 1 diabetes and their parents. The Schedule for the Evaluation of Individualised Quality of Life (SEIQoL) interview was adapted to be (1) insulin pum...

  18. Insulin Therapy

    Science.gov (United States)

    ... insert the strip into a machine called an electronic glucose meter. The results will tell you whether ... Article >>Allergy Shots: Could They Help Your Allergies?Plasma Viral Load TestingRead Article >>Plasma Viral Load TestingHow ...

  19. Identification of barriers to insulin therapy and approaches to overcoming them

    DEFF Research Database (Denmark)

    Russell-Jones, D; Pouwer, F; Khunti, K

    2018-01-01

    Poor glycaemic control in type 2 diabetes (T2D) is a global problem despite the availability of numerous glucose-lowering therapies and clear guidelines for T2D management. Tackling clinical or therapeutic inertia, where the person with diabetes and/or their healthcare providers do not intensify...... delayed for several years. Patient- and physician-related factors both contribute to this resistance at the stages of insulin initiation, titration and intensification, impeding achievement of optimal glycaemic control. This review evaluates the evidence and reasons for this delay, together with available...

  20. Lipid Rescue Therapy and High-Dose insulin Euglycemic Therapy are Effective for Severe Refractory Calcium Channel Blocker Overdose: Case Report and Review of Literature

    Directory of Open Access Journals (Sweden)

    Niko Bekjarovski

    2013-09-01

    How to cite this article: Bekjarovski NG. Lipid Rescue Therapy and High-Dose insulin Euglycemic Therapy are Effective for Severe Refractory Calcium Channel Blocker Overdose: Case Report and Review of Literature. Asia Pac J Med Toxicol 2013;2:114-6.

  1. Preliminary Evaluation of a New Semi-Closed-Loop Insulin Therapy System Over the Prandial Period in Adult Patients With Type 1 Diabetes

    Science.gov (United States)

    Quemerais, Marie Aude; Doron, Maeva; Dutrech, Florent; Melki, Vincent; Franc, Sylvia; Antonakios, Michel; Charpentier, Guillaume; Hanaire, Helene; Charpentier, Guillaume

    2014-01-01

    There is room for improvement in the algorithms used in closed-loop insulin therapy during the prandial period. This pilot study evaluated the efficacy and safety of the Diabeloop algorithm (model predictive control type) during the postprandial period. This 2-center clinical trial compared interstitial glucose levels over two 5-hour periods (with/without the algorithm) following a calibrated lunch. On the control day, the amount of insulin delivered by the pump was determined according to the patient’s usual parameters. On the test day, 50% or 75% of the theoretical bolus required was delivered, while the algorithm, informed of carbohydrate intake, proposed changes to insulin delivery every 15 minutes using modeling to forecast glucose levels. The primary endpoint was percentage of time spent at near normoglycemia (70-180 mg/dl). Twelve patients with type 1 diabetes (9 men, age 35.6 ± 12.7 years, HbA1c 7.3 ± 0.8%) were included. The percentage of time spent in the target range was 84.5 ± 20.8 (test day) versus 69.2 ± 33.9% (control day, P = .11). The percentage of time spent in hypoglycemia < 70 mg/dl was 0.2 ± 0.8 (test) versus 4.4 ± 8.2% (control, P = .18). Interstitial glucose at the end of the test (5 hours) was 127.5 ± 40.1 (test) versus 146 ± 53.5 mg/dl (control, P = .25). The insulin doses did not differ, and no differences were observed between the 50% and 75% boluses. In a semi-closed-loop configuration with manual priming boluses (25% or 50% reduction), the Diabeloop v1 algorithm was as successful as the manual method in determining the prandial bolus, without any exposure to excessive hypoglycemic risk. PMID:25097057

  2. Simulation and qualitative analysis of glucose variability, mean glucose, and hypoglycemia after subcutaneous insulin therapy for stress hyperglycemia.

    Science.gov (United States)

    Strilka, Richard J; Stull, Mamie C; Clemens, Michael S; McCaver, Stewart C; Armen, Scott B

    2016-01-27

    The critically ill can have persistent dysglycemia during the "subacute" recovery phase of their illness because of altered gene expression; it is also not uncommon for these patients to receive continuous enteral nutrition during this time. The optimal short-acting subcutaneous insulin therapy that should be used in this clinical scenario, however, is unknown. Our aim was to conduct a qualitative numerical study of the glucose-insulin dynamics within this patient population to answer the above question. This analysis may help clinicians design a relevant clinical trial. Eight virtual patients with stress hyperglycemia were simulated by means of a mathematical model. Each virtual patient had a different combination of insulin resistance and insulin deficiency that defined their unique stress hyperglycemia state; the rate of gluconeogenesis was also doubled. The patients received 25 injections of subcutaneous regular or Lispro insulin (0-6 U) with 3 rates of continuous nutrition. The main outcome measurements were the change in mean glucose concentration, the change in glucose variability, and hypoglycemic episodes. These end points were interpreted by how the ultradian oscillations of glucose concentration were affected by each insulin preparation. Subcutaneous regular insulin lowered both mean glucose concentrations and glucose variability in a linear fashion. No hypoglycemic episodes were noted. Although subcutaneous Lispro insulin lowered mean glucose concentrations, glucose variability increased in a nonlinear fashion. In patients with high insulin resistance and nutrition at goal, "rebound hyperglycemia" was noted after the insulin analog was rapidly metabolized. When the nutritional source was removed, hypoglycemia tended to occur at higher Lispro insulin doses. Finally, patients with severe insulin resistance seemed the most sensitive to insulin concentration changes. Subcutaneous regular insulin consistently lowered mean glucose concentrations and glucose

  3. Effect of Insulin Therapy using Hyper-insulinemic Normoglycemic Clamp on Inflammatory Response in Brain Dead Organ Donors.

    Science.gov (United States)

    Aljiffry, M; Hassanain, M; Schricker, T; Shaheen, M; Nouh, T; Lattermann, R; Salman, A; Wykes, L; Metrakos, P

    2016-05-01

    Brain death is a major stress that is associated with a massive inflammatory response and systemic hyperglycemia. Severe inflammation leads to increased graft immunogenicity and risk of graft dysfunction; while acute hyperglycemia aggravates the inflammatory response and increases the risk of morbidity and mortality. Insulin therapy not only controls hyperglycemia but also suppresses inflammation. The present study is to investigate the anti-inflammatory properties and the normoglycemia maintenance of high dose insulin on brain dead organ donors. 15 brain dead organ donors were divided into 2 groups, insulin treated (n=6) and controls (n=9). Insulin was provided for a minimum of 6 h using the hyperinsulinemic normoglycemic clamp technique. The changes of serum cytokines, including IL-6, IL-10, IL-1β, IL-8, TNFα, TGFα and MCP-1, were measured by suspension bead array immunoassay and glucose by a glucose monitor. Compared to controls, insulin treated donors had a significant lower blood glucose 4.8 (4-6.9) vs. 9 (5.6-11.7) mmol/L, pinsulin treated donors compared with those in controls. High dose insulin therapy decreases the concentrations of inflammatory cytokines in brain dead donors and preserves normoglycemia. High dose of insulin may have anti-inflammatory effects in brain dead organ donors and therefore, improve the quality of donor organs and potentially improve outcomes. © Georg Thieme Verlag KG Stuttgart · New York.

  4. The effect of functional insulin therapy on glycaemic parameters in children with diabetes mellitus type 1.

    Science.gov (United States)

    Štimjanin-Koldžo, Diana; Alajbegović, Salem; Štimjanin, Ena; Mehinagić, Jasmina

    2017-08-01

    Aim The aim of the study is to evaluate the effect of a prospectively conducted interactive 5-day education programme based on Düsseldorf model on glycated haemoglobin (A1C), and total daily dose of insulin in type 1 diabetes patients. Methods A total of 67 type 1 diabetes patients was analysed; mean age of 11±0.68 years, 43 females and 24 males. The programme was led by a trained team of diabetes specialist doctors and nurses. All subjects and their parents completed a knowledge test about diabetes at beginning, and at the end of education, and after 12 months (30 questions). Subjects were evaluated for total daily insulin, and HbA1c at baseline, as well as 3, 6, 9 and 12 months after the end of the education programme. Results Results of the knowledge test after the education have shown higher knowledge at baseline. At the end of the education programme an average of total daily insulin dose was significantly lower. There was a 3.17% reduction in HbA1c values over 9 months, and 1.8% over 12 months in the comparison to the baseline values (p1). Conclusions Structured education programme of functional insulin therapy was associated with improved glycaemic control in type 1 diabetes patients and their parents. It motivated patients and parents to improve glycaemic control. One year after the follow up, glycaemic control was worsening, due to lack of patients' motivation, therefore, there is a need for yearly re-education. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  5. Effectiveness of basal-supported oral therapy (BOT) using insulin glargine in patients with poorly controlled type 2 diabetes.

    Science.gov (United States)

    Suzuki, Daisuke; Umezono, Tomoya; Miyauchi, Masaaki; Kimura, Moritsugu; Yamamoto, Naoyuki; Tanaka, Eitaro; Kuriyama, Yusuke; Sato, Hiroki; Miyatake, Han; Kondo, Masumi; Toyoda, Masao; Fukagawa, Masafumi

    2012-07-20

    To determine the clinical usefulness of basal-supported oral therapy (BOT) using insulin glargine in Japanese patients with type 2 diabetes. We compared HbA1c levels, body weight, and insulin doses before the introduction of BOT and in the final month of the observation period in 122 patients with type 2 diabetes who received BOT with insulin glargine between October 2007 and July 2009. To exclude the possible effects of seasonal changes in glycemic control, 57 of the 122 patients were followed-up for one year and examined for changes in HbA1c levels, body weight, and insulin dose. Examination of all cases (n=122) showed a significant decrease in HbA1c (before BOT: 8.7±1.8, after: 7.1±1.1%), but no significant change in body weight (before: 63.1±16.1, after: 63.8±17.0 kg). The mean observation period was 10.5±6.4 months. Insulin doses were significantly increased during the study. HbA1c levels improved significantly in patients on non-insulin-secreting drugs (biguanide, α-glucosidase inhibitor and thiazolidine derivatives) than those on insulin-secreting drugs (SU agents and glinides). BOT with insulin glargine is a useful strategy that can achieve good glycemic control in clinical practice without causing serious hypoglycemia. The introduction of BOT before exhaustion of pancreatic β cells may increase its effectiveness.

  6. Glycemic control and adherence to basal insulin therapy in Taiwanese patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Chien, Ming-Nan; Chen, Yen-Ling; Hung, Yi-Jen; Wang, Shu-Yi; Lu, Wen-Tsung; Chen, Chih-Hung; Lin, Ching-Ling; Huang, Tze-Pao; Tsai, Ming-Han; Tseng, Wei-Kung; Wu, Ta-Jen; Ho, Cheng; Lin, Wen-Yu; Chen, Bill; Chuang, Lee-Ming

    2016-11-01

    The aim of the present study was to assess the glycemic control, adherence and treatment satisfaction in a real-world setting with basal insulin therapy in type 2 diabetes patients in Taiwan. This was a multicenter, prospective, observational registry. A total of 836 patients with type 2 diabetes taking oral antidiabetic drugs with glycated hemoglobin (HbA1c) >7% entered the study. Basal insulin was given for 24 weeks. All treatment choices and medical instructions were at the physician's discretion to reflect real-life practice. After 24-week treatment, 11.7% of patients reached set HbA1c goals without severe hypoglycemia (primary effectiveness end-point). HbA1c and fasting blood glucose were significantly decreased from (mean ± SD) 10.1 ± 1.9% to 8.7 ± 1.7% (-1.4 ± 2.1%, P 1) and from 230.6 ± 68.8 mg/dL to 159.1 ± 55.6 mg/dL (-67.4 ± 72.3 mg/dL, P 1), respectively. Patients received insulin therapy at a frequency of nearly one shot per day on average, whereas self-monitoring of blood glucose was carried out approximately four times a week. Hypoglycemia was reported by 11.4% of patients, and only 0.7% of patients experienced severe hypoglycemia. Slight changes in weight (0.7 ± 2.4 kg) and a low incidence of adverse drug reactions (0.4%) were also noted. The score of 7-point treatment satisfaction rated by patients was significantly improved by 1.9 ± 1.7 (P 1). Basal insulin therapy was associated with a decrease in HbA1c and fasting blood glucose, and an improved treatment satisfaction. Most patients complied with physicians' instructions. The treatment was generally well tolerated by patients with type 2 diabetes, but findings pointed out the need to reinforce the early and appropriate uptitration to achieve treatment targets. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  7. Determinants of renal potassium excretion in critically ill patients : The role of insulin therapy

    NARCIS (Netherlands)

    Hoekstra, Miriam; Yeh, Lu; Oude Lansink, Annemieke; Vogelzang, Mathijs; Stegeman, Coen A.; Rodgers, Michael G. G.; van der Horst, Iwan C. C.; Wietasch, Gotz; Zijlstra, Felix; Nijsten, Maarten W. N.

    Objectives: Insulin administration lowers plasma potassium concentration by augmenting intracellular uptake of potassium. The effect of insulin administration on renal potassium excretion is unclear. Some studies suggest that insulin has an antikaliuretic effect although plasma potassium levels were

  8. From the Cover: Cell-replacement therapy for diabetes: Generating functional insulin-producing tissue from adult human liver cells

    Science.gov (United States)

    Sapir, Tamar; Shternhall, Keren; Meivar-Levy, Irit; Blumenfeld, Tamar; Cohen, Hamutal; Skutelsky, Ehud; Eventov-Friedman, Smadar; Barshack, Iris; Goldberg, Iris; Pri-Chen, Sarah; Ben-Dor, Lya; Polak-Charcon, Sylvie; Karasik, Avraham; Shimon, Ilan; Mor, Eytan; Ferber, Sarah

    2005-05-01

    Shortage in tissue availability from cadaver donors and the need for life-long immunosuppression severely restrict the large-scale application of cell-replacement therapy for diabetic patients. This study suggests the potential use of adult human liver as alternate tissue for autologous beta-cell-replacement therapy. By using pancreatic and duodenal homeobox gene 1 (PDX-1) and soluble factors, we induced a comprehensive developmental shift of adult human liver cells into functional insulin-producing cells. PDX-1-treated human liver cells express insulin, store it in defined granules, and secrete the hormone in a glucose-regulated manner. When transplanted under the renal capsule of diabetic, immunodeficient mice, the cells ameliorated hyperglycemia for prolonged periods of time. Inducing developmental redirection of adult liver offers the potential of a cell-replacement therapy for diabetics by allowing the patient to be the donor of his own insulin-producing tissue. pancreas | transdifferentiation

  9. NASH Therapy: omega 3 supplementation, vitamin E, insulin sensitizers and statin drugs

    Directory of Open Access Journals (Sweden)

    Stephen Caldwell

    2017-06-01

    Full Text Available Non-alcoholic steatohepatitis (NASH is the more aggressive form of non-alcoholic fatty liver disease (NAFLD. NASH can progress to hepatic fibrosis, cirrhosis, portal hypertension and primary liver cancer. Therapy is evolving with a substantial number of trials of promising new agents now in progress. In this article however, we will examine data for several older forms of therapy which have been fairly extensively studied over the years: Polyunsaturated Fatty Acid (PUFA supplements, vitamin E, insulin sensitizing agents with a focus on pioglitazone and statin agents. Early interest in PUFA derived from their potential benefit in cardio-metabolic disease and the close association of NAFLD/NASH with Metabolic Syndrome. Results have been variable although most studies show reduction of liver fat without other major effects and their effects are influenced by concomitant weight loss and underlying genetic factors. Vitamin E has had some efficacy in pediatric NASH but questionable efficacy in even mild NASH among adults. Pioglitazone has shown significant histological benefit in a number of trials but concern over side-effects (especially weight gain have dampened enthusiasm. A newer insulin sensitizer, liraglutide, has also shown promise in a small randomized, controlled trial. Very limited data exists regarding the histological effects of the statins in NASH and these agents appear to be fairly neutral with neither clear cut benefit nor detriment. Their use is best guided by cardiovascular risks rather than liver histology.

  10. Heterogeneity of change in state affect following insulin therapy initiation in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Gruszczyńska Ewa

    2017-09-01

    Full Text Available The aim of the study was to explore heterogeneity of change in state affect following the introduction of insulin therapy in patients with type 2 diabetes. State affect was assessed twice among 305 patients: just before the introduction of insulin therapy and at 1-month follow-up. Latent class growth modeling showed that negative affect (NA increased in 78% of the sample, whereas positive affect (PA improved in only 17% of the participants. On the basis of cross-tabulation of these changes a 4-class model of emotional response to the new treatment was obtained. The largest subgroup of participants (57% manifested “threat response”, i.e. moderate-stable PA with increase in NA. Participants in the “challenge response” subgroup (11.8% showed increases in both NA and PA. The third class (10.2% characterized by “no response”, had low-stable NA and moderate-stable PA. The smallest “stress response” subgroup (9.8% showed increase in NA and high-stable PA. Gender, age and education level were significant covariates of group membership. Thus, the findings revealed heterogeneous emotional response to the new treatment, which may be of clinical relevance for improving diabetic patients’ adjustment through a more individual, person-centered approach.

  11. Survey of findings in patients having persistent heartburn on proton pump inhibitor therapy.

    Science.gov (United States)

    Mandaliya, R; DiMarino, A J; Cohen, S

    2016-01-01

    In patients with refractory heartburn while on proton pump inhibitor (PPI) therapy, changing drugs or increasing treatment to a twice a day (b.i.d.) dose has become a common practice. This study aims to study patients with persistent heartburn while on PPI therapy and to determine if persistent symptom indicates the need for more aggressive or different therapy. A retrospective review of impedance-pH tracings on PPI therapy (q.d. or b.i.d.) for patients with persistent heartburn was performed. DeMeester score, impedance, and symptom sensitive index (SSI) were used as indices. Statistical analyses were performed using chi-squared test with Yates correction and paired t-test. One hundred consecutive patients, (female 50%, male 50%, mean age 54 [range 16-83] years) were studied on q.d. (n = 45) or b.i.d. PPI (n = 55). Only 20% of the patients had abnormal DeMeester score; 41% had an abnormal impedance score and 56% had abnormal SSI; 29% had all indices normal. There was no difference between patients taking q.d. versus b.i.d. PPI for abnormal DeMeester score (22 vs. 18%), impedance (38 vs. 44%) and SSI (53 vs. 58%); P = 0.80, 0.69, and 0.77, respectively. In 56 patients with positive SSI, symptoms were due to acid reflux in 8 (14%) patients, nonacid reflux in 31 (55%) patients, and combined acid and nonacid reflux in 17 (30%) patients. Patients with persistent heartburn on PPI therapy show a variety of disorders: (i) acid reflux (20%); (ii) nonacid reflux (26%); (iii) positive SSI (56%); (iv) all normal indices (29%). These studies indicate that persistent heartburn on PPI therapy is a complex problem that may not respond to simply increasing acid inhibition. © 2014 International Society for Diseases of the Esophagus.

  12. THE MEANING OF INSULIN PUMPE THERAPY TO ADULT PATIENTS WITH TYPE 1 DIABETES

    DEFF Research Database (Denmark)

    Nissen, Heidi; Aagaard, Hanne

    on a semi-structured interview guide inspired by Van Manens four fundamental existentials. The interviews were analyzed according to 3 interpretation contexts as described by Kvale and Brinkmann. The first step paraphrases what the patients say. The second step analyses critically what patients say...

  13. Effect of intensive vs conventional insulin therapy on perioperative nutritional substrates metabolism in patients undergoing gastrectomy

    Institute of Scientific and Technical Information of China (English)

    Han-Cheng Liu; Yan-Bing Zhou; Dong Chen; Zhao-Jian Niu; Yang Yu

    2012-01-01

    AIM:To investigate the effect of intensive vs conventional insulin therapy on perioperative nutritional substrates metabolism in patients undergoing radical distal gastrectomy.METHODS:Within 24 h of intensive care unit management,patients with gastric cancer were enrolled after written informed consent and randomized to the intensive insulin therapy (IIT) group to keep glucose levels from 4.4 to 6.1 mmol/L or the conventional insulin therapy (CIT) group to keep levels less than 10 mmol/L.Resting energy expenditure (REE),respiratory quotient (RQ),resting energy expenditure per kilogram (REE/kg),and the lipid oxidation rate were monitored by the indirect calorimeter of calcium citrate malate nutrition metabolism investigation system.The changes in body composition were analyzed by multi-frequency bioimpedance analysis.Blood fasting glucose and insulin concentration were measured for assessment of Homeostasis model assessment of insulin resistance.RESULTS:Sixty patients were enrolled.Compared with preoperative baseline,postoperative REE increased by over 22.15% and 11.07%; REE/kg rose up to 27.22 ± 1.33 kcal/kg and 24.72 ± 1.43 kcal/kg; RQ decreased to 0.759 ± 0.034 and 0.791 ± 0.037; the lipid oxidation ratio was up to 78.25% ± 17.74% and 67.13% ± 12.76% supported by parenteral nutrition solutions from 37.56% ± 11.64% at the baseline; the level of Ln-HOMA-IR went up dramatically (P < 0.05,respectively) on postoperative days 1 and 3 in the IIT group.Meanwhile the concentration of total protein,albumin and triglyceride declined significantly on postoperative days 1 and 3 compared with pre-operative levels (P < 0.05,respectively).Compared with the CIT group,IIT reduced the REE/kg level (27.22 ± 1.33 kcal/kg vs 29.97 ± 1.47 kcal/kg,P =0.008; 24.72 ± 1.43 kcal/kg vs 25.66 ± 1.63 kcal/kg,P =0.013); and decreased the Ln-HOMA-IR score (P =0.019,0.028) on postoperative days 1 and 3; IIT decreased the level of CRP on postoperative days 1 and 3 (P

  14. Successful treatment of young infants presenting neonatal diabetes mellitus with continuous subcutaneous insulin infusion before genetic diagnosis.

    Science.gov (United States)

    Rabbone, Ivana; Barbetti, Fabrizio; Marigliano, Marco; Bonfanti, Riccardo; Piccinno, Elvira; Ortolani, Federica; Ignaccolo, Giovanna; Maffeis, Claudio; Confetto, Santino; Cerutti, Franco; Zanfardino, Angela; Iafusco, Dario

    2016-08-01

    Neonatal diabetes mellitus (NDM) is defined as hyperglycemia and impaired insulin secretion with onset within 6 months of birth. While rare, NDM presents complex challenges regarding the management of glycemic control. The availability of continuous subcutaneous insulin infusion pumps (CSII) in combination with continuous glucose monitoring systems (CGM) provides an opportunity to monitor glucose levels more closely and deliver insulin more safely. We report four cases of young infants with NDM successfully treated with CSII and CGM. Moreover, in two cases with Kir 6.2 mutation, we describe the use of CSII in switching therapy from insulin to sulfonylurea treatment. Insulin pump requirement for the 4 neonatal diabetes cases was the same regardless of disease pathogenesis and c-peptide levels. No dilution of insulin was needed. The use of an integrated CGM system helped in a more precise control of BG levels with the possibility of several modifications of insulin basal rates. Moreover, as showed in the first two case-reports, when the treatment was switched from insulin to glibenclamide, according to identification of Kir 6.2 mutation and diagnosis of NPDM, the CSII therapy demonstrated to be helpful in allowing gradual insulin suspension and progressive introduction of sulfonylurea. During the neonatal period, the use of CSII therapy is safe, more physiological, accurate and easier for the insulin administration management. Furthermore, CSII therapy is safe during the switch of therapy from insulin to glibenclamide for infants with permanent neonatal diabetes mellitus.

  15. Insulin delivery route for the artificial pancreas: subcutaneous, intraperitoneal, or intravenous? Pros and cons.

    Science.gov (United States)

    Renard, Eric

    2008-07-01

    Insulin delivery is a crucial component of a closed-loop system aiming at the development of an artificial pancreas. The intravenous route, which has been used in the bedside artificial pancreas model for 30 years, has clear advantages in terms of pharmacokinetics and pharmacodynamics, but cannot be used in any ambulatory system so far. Subcutaneous (SC) insulin infusion benefits from the broad expansion of insulin pump therapy that promoted the availability of constantly improving technology and fast-acting insulin analog use. However, persistent delays of insulin absorption and action, variability and shortterm stability of insulin infusion from SC-inserted catheters generate effectiveness and safety issues in view of an ambulatory, automated, glucose-controlled, artificial beta cell. Intraperitoneal insulin delivery, although still marginally used in diabetes care, may offer an interesting alternative because of its more-physiological plasma insulin profiles and sustained stability and reliability of insulin delivery.

  16. Esophageal mucosal breaks in gastroesophageal reflux disease partially responsive to proton pump inhibitor therapy.

    Science.gov (United States)

    Shaheen, Nicholas J; Denison, Hans; Björck, Karin; Silberg, Debra G

    2013-04-01

    Approximately 20-30% of patients with gastroesophageal reflux disease (GERD) do not experience complete symptom resolution during proton pump inhibitor (PPI) therapy. The aim of this study was to determine the prevalence of esophageal mucosal breaks among patients who have a partial response to PPI therapy. This was an analysis of data from a phase 2b clinical trial carried out to assess the efficacy and safety of a reflux inhibitor, lesogaberan (AZD3355), as an add-on to PPI therapy in this patient population (clinicaltrials.gov reference: NCT01005251). A total of 661 patients with persistent GERD symptoms who had received a minimum of 4 weeks of PPI therapy were included in the study. The prevalence of esophageal mucosal breaks was assessed according to (i) the most recent endoscopy results from within the previous 24 months, if available ("historical" endoscopies), and (ii) the results of endoscopies performed at study baseline ("baseline" endoscopies). Baseline endoscopies were not carried out in patients who had a historical endoscopy showing an absence of esophageal mucosal breaks. Historical endoscopy results were available for 244 patients, of whom 48 (19.7%) had esophageal mucosal breaks. Baseline endoscopies were carried out in 465 patients, of whom 146 (31.4%) had esophageal mucosal breaks. Sensitivity analyses showed a prevalence of esophageal mucosal breaks of 20-30%. In both the historical and baseline endoscopies, most esophageal mucosal breaks were Los Angeles grades A or B. In patients with GERD symptoms partially responsive to PPI therapy, mild-to-moderate severity esophageal mucosal breaks are common (prevalence 20-30%), and may contribute to symptom etiology.

  17. Factors associated with residual gastroesophageal reflux disease symptoms in patients receiving proton pump inhibitor maintenance therapy.

    Science.gov (United States)

    Kawara, Fumiaki; Fujita, Tsuyoshi; Morita, Yoshinori; Uda, Atsushi; Masuda, Atsuhiro; Saito, Masaya; Ooi, Makoto; Ishida, Tsukasa; Kondo, Yasuyuki; Yoshida, Shiei; Okuno, Tatsuya; Yano, Yoshihiko; Yoshida, Masaru; Kutsumi, Hiromu; Hayakumo, Takanobu; Yamashita, Kazuhiko; Hirano, Takeshi; Hirai, Midori; Azuma, Takeshi

    2017-03-21

    To elucidate the factors associated with residual gastroesophageal reflux disease (GERD) symptoms in patients receiving proton pump inhibitor (PPI) maintenance therapy in clinical practice. The study included 39 GERD patients receiving maintenance PPI therapy. Residual symptoms were assessed using the Frequency Scale for Symptoms of GERD (FSSG) questionnaire and the Gastrointestinal Symptom Rating Scale (GSRS). The relationships between the FSSG score and patient background factors, including the CYP2C19 genotype, were analyzed. The FSSG scores ranged from 1 to 28 points (median score: 7.5 points), and 19 patients (48.7%) had a score of 8 points or more. The patients' GSRS scores were significantly correlated with their FSSG scores (correlation coefficient = 0.47, P reflux-related symptom scores: 12 ± 1.9 vs 2.5 ± 0.8, P reflux disease patients were significantly lower than those of the other patients (total scores: 5.5 ± 1.0 vs 11.8 ± 6.3, P < 0.05; dysmotility symptom-related scores: 1.0 ± 0.4 vs 6.0 ± 0.8, P < 0.01). Approximately half of the GERD patients receiving maintenance PPI therapy had residual symptoms associated with a lower quality of life, and the CYP2C19 genotype appeared to be associated with these residual symptoms.

  18. [Adherence with proton pump inhibitor therapy, by continuously taking nonsteroidal anti-inflammatory drugs].

    Science.gov (United States)

    Pimanov, S I; Makarenko, E V; Dikareva, E A

    2015-01-01

    To estimate the impact of adherence with proton pump inhibitor (PPI) therapy on the incidence of nonsteroidal anti-inflammatory drug (NSAID)-induced gastropathy (NSAID gastropathy) in patients with rheumatoid arthritis (RA). PPI pharmacotherapy adherence was estimated using the Medication Adherence Questionnaire (MAQ) in 92 patients with RA, including 32 patients did not take a PPI and 60 used a PPI. The groups were matched for age, disease duration, and used NSAIDs. All those asked underwent video esophagogastroduodenoscopy. According to the data of MAQ survey, low, moderate, and high adherence subgroups could be identified among the patients treated with a PPI. NSAID gastropathy was detected in 43.8% of the patients taking no PPI, in 50% of those with low PPI treatment adherence, in 12.5% with moderate adherence, and in 4.5% with high adherence. In the patients with low adherence to PPI therapy, NSAID gastropathy was recorded 11 times more frequently than in those with high adherence (c2 = 7.77; p = 0.005). This condition occurred in 28.6% of the patients taking NSAID without preventively using a PPI in the absence of risk factors for NSAID gastropathy. Only 36.7% patients who had been recommended to use a PPI for the prevention of NSAID gastropathy strictly observed their doctor's directions. Low PPI pharmacotherapy adherence may serve as an additional risk factor for NSAID gastropathy in patients in whom preventive antisecretory therapy used in combination with NSAID is indicated.

  19. [Prospective observational study of insulin detemir in patients with poorly controlled type 2 diabetes mellitus initiating insulin therapy for the first time (SOLVE Study)].

    Science.gov (United States)

    Orozco-Beltrán, Domingo; Artola-Menéndez, Sara

    2016-02-01

    Describe the experience in the primary care setting with insulin detemir in patients with poorly controlled type2 diabetes mellitus that need to add-on insulin to their oral antidiabetic drug therapy. Prospective observational study of 6 months of follow up, performed in 10 countries. In Spain, participating sites were only from the primary care setting. Eligible patients were those with poorly controlled type2 diabetes mellitus adding-on once-daily insulin detemir to their existing oral antidiabetic therapy in the month prior to their enrollment. The change of Hb1Ac and of weight at the end of the study and the incidence of hypoglycemia and adverse reactions, were analyzed. We report the results obtained in the Spanish cohort. Overall 17,374 patients were included, 973 in Spain [mean age 64.8 years (SE 12); duration of diabetes 9.4 years (SE 6.2); Hb1Ac 8.9% (DE 1.4)]. In the sample analyzed for efficacy (n=474) the mean change of Hb1Ac was -1.6% (95%CI: -1.75 to -1.42; P<.001), mean change of weight was -2.9 kg (95%CI: -3.72 to -2.08; P<.001). Only one episode of severe hypoglycemia was reported, which was also the only serious adverse reaction reported in the study. The incidence rate of non-severe hypoglycemia was 2.44 events/patient-year. In this cohort of patients with type 2 diabetes mellitus receiving newly initiated insulin therapy, once-daily detemir improved the glycemic control, with low incidence of hypoglycemia and a significant reduction of the weight. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  20. Insulin Therapy for Adult Patients with Type 2 Diabetes Mellitus: A Position Statement of the Korean Diabetes Association, 2017.

    Science.gov (United States)

    Lee, Byung Wan; Kim, Jin Hwa; Ko, Seung Hyun; Hur, Kyu Yeon; Kim, Nan Hee; Rhee, Sang Youl; Kim, Hyun Jin; Moon, Min Kyong; Park, Seok O; Choi, Kyung Mook

    2017-10-01

    The Korean Diabetes Association (KDA) has regularly updated its Clinical Practice Guidelines. In 2017, the KDA published a position statement on the use of antihyperglycemic agents for patients with type 2 diabetes mellitus (T2DM). Growing evidence from new multinational clinical trials using novel and traditional insulin analogues has also been accumulated. Following global trends, many results of clinical trials, especially concerning the clinical efficacy and safety of insulin therapy, have been published about Korean patients with T2DM. After a systematic search of recent evidence, the KDA updated and modified its clinical practice recommendations regarding the initiation, choice, and intensification of insulin and created an insulin treatment algorithm for the first time to guide physicians caring for adult Korean patients with T2DM. Copyright © 2017 Korean Diabetes Association.

  1. Insulin Therapy for Adult Patients with Type 2 Diabetes Mellitus: A Position Statement of the Korean Diabetes Association, 2017

    Directory of Open Access Journals (Sweden)

    Byung-Wan Lee

    2017-10-01

    Full Text Available The Korean Diabetes Association (KDA has regularly updated its Clinical Practice Guidelines. In 2017, the KDA published a position statement on the use of antihyperglycemic agents for patients with type 2 diabetes mellitus (T2DM. Growing evidence from new multinational clinical trials using novel and traditional insulin analogues has also been accumulated. Following global trends, many results of clinical trials, especially concerning the clinical efficacy and safety of insulin therapy, have been published about Korean patients with T2DM. After a systematic search of recent evidence, the KDA updated and modified its clinical practice recommendations regarding the initiation, choice, and intensification of insulin and created an insulin treatment algorithm for the first time to guide physicians caring for adult Korean patients with T2DM.

  2. [Increasing cost of insulin therapy in Belgium. From a critical analysis of the situation to a search for practical solutions].

    Science.gov (United States)

    Scheen, A J

    2006-09-01

    Cost related to insulin therapy is markedly increasing in Belgium, as in other Eucopean countries. In the present paper, we will briefly analyze the main reasons for such aa increase, integrate such observation withIn the global context of diabetes management and suggest some solutions to provide best care to insulin-treated diabetic patients at a reasonable cost. The rise of the cost of insulin therapy has a multifactorial origin. It mainly results from an increase in the number of diabetic patients, a more intensive management, In both type 1 and type 2 diabetes, and a greater use of more expansive insulin analogues. It is important to analyze the increase of the cost of insulin therapy within the global burden of diabetes melitus. Only a better responsibility of all health care partners, patients, physicians, pharmaceutical companies, public health authorities, could provide solutions allowing diabetic people to profit from best treatments they should receive in order to prevent diabetic complications, by far the main cause of expenses.

  3. The Barbados Insulin Matters (BIM study: Barriers to insulin therapy among a population-based sample of people with type 2 diabetes in the Caribbean island of Barbados

    Directory of Open Access Journals (Sweden)

    Charles G. Taylor, Jr.

    2017-06-01

    Conclusions: Multiple factors related to patient beliefs and attitudes need to be considered and addressed when initiating insulin in order to minimise psychological insulin resistance and delay. Patients using insulin had less negative perceptions than those not on insulin.

  4. Failure to initiate early insulin therapy - A risk factor for diabetic retinopathy in insulin users with Type 2 diabetes mellitus: Sankara Nethralaya-Diabetic Retinopathy Epidemiology and Molecular Genetics Study (SN-DREAMS, Report number 35).

    Science.gov (United States)

    Gupta, Aditi; Delhiwala, Kushal S; Raman, Rajiv P G; Sharma, Tarun; Srinivasan, Sangeetha; Kulothungan, Vaitheeswaran

    2016-06-01

    Insulin users have been reported to have a higher incidence of diabetic retinopathy (DR). The aim was to elucidate the factors associated with DR among insulin users, especially association between duration, prior to initiating insulin for Type 2 diabetes mellitus (DM) and developing DR. Retrospective cross-sectional observational study included 1414 subjects having Type 2 DM. Insulin users were defined as subjects using insulin for glycemic control, and insulin nonusers as those either not using any antidiabetic treatment or using diet control or oral medications. The duration before initiating insulin after diagnosis was calculated by subtracting the duration of insulin usage from the duration of DM. DR was clinically graded using Klein's classification. SPSS (version 9.0) was used for statistical analysis. Insulin users had more incidence of DR (52.9% vs. 16.3%, P 1) and sight threatening DR (19.1% vs. 2.4%, P 1) in comparison to insulin nonusers. Among insulin users, longer duration of DM (odds ratio [OR] 1.12, 95% confidence interval [CI] 1.00-1.25, P = 0.044) and abdominal obesity (OR 1.15, 95% CI 1.02-1.29, P = 0.021) was associated with DR. The presence of DR was significantly associated with longer duration (≥5 years) prior to initiating insulin therapy, overall (38.0% vs. 62.0%, P = 0.013), and in subjects with suboptimal glycemic control (32.5% vs. 67.5%, P = 0.022). The presence of DR is significantly associated with longer duration of diabetes (>5 years) and sub-optimal glycemic control (glycosylated hemoglobin insulin users, abdominal obesity was found to be a significant predictor of DR; DR is associated with longer duration prior to initiating insulin therapy in Type 2 DM subjects with suboptimal glycemic control.

  5. Remission without insulin therapy on gluten-free diet in a 6-year old boy with type 1 diabetes mellitus

    DEFF Research Database (Denmark)

    Sildorf, Stine Møller; Fredheim, Siri; Svensson, Jannet

    2012-01-01

    A 5-year and 10-month old boy was diagnosed with classical type 1 diabetes mellitus (T1DM) without celiac disease. He started on a gluten-free diet after 2–3 week without need of insulin treatment. At the initiation of gluten-free diet, HbA1c was 7.8% and was stabilised at 5.8%–6.0% without insulin...... therapy. Fasting blood glucose was maintained at 4.0–5.0 mmol/l. At 16 months after diagnosis the fasting blood glucose was 4.1 mmol/l and after 20 months he is still without daily insulin therapy. There was no alteration in glutamic acid decarboxylase positivity. The gluten-free diet was safe and without...... side effects. The authors propose that the gluten-free diet has prolonged remission in this patient with T1DM and that further trials are indicated....

  6. Effects of switching from prandial premixed insulin therapy to basal plus two times bolus insulin therapy on glycemic control and quality of life in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Ito H

    2014-04-01

    Full Text Available Hiroyuki Ito, Mariko Abe, Shinichi Antoku, Takashi Omoto, Masahiro Shinozaki, Shinya Nishio, Mizuo Mifune, Michiko ToganeDepartment of Diabetes, Metabolism and Kidney Disease, Edogawa Hospital, Tokyo, JapanBackground: The effects of switching from prandial premixed insulin therapy (PPT injected three times a day to basal plus two times bolus insulin therapy (B2B on glycemic control and quality of life were investigated in patients with type 2 diabetes mellitus.Methods: The clinical course was prospectively observed during the first 16 weeks after switching to B2B (insulin glargine plus insulin glulisine before breakfast and dinner in 27 subjects previously treated with PPT using 50/50 premixed insulin. The Diabetes Treatment Satisfaction Questionnaire (DTSQ was administered at the start and end of the study.Results: The glycated hemoglobin (HbA1c level (8.3%±1.8% to 8.2%±1.1% and the DTSQ score did not change between the start and end of the study. An improvement in HbA1c level was found in nine (33% subjects. The change in HbA1c showed a significant negative correlation with baseline HbA1c, and was significantly better in patients with a baseline HbA1c >8.0% than in those with an HbA1c ≤8.0% (−0.9±2.0 versus 0.3±0.6, respectively, P=0.02. The change in DTSQ score representing treatment satisfaction was significantly greater in patients whose HbA1c level was improved than in those in whom it was not (2.7±3.6 versus −0.8±3.5, P=0.04.Conclusion: B2B was noninferior to PPT with regard to HbA1c levels in patients with type 2 diabetes mellitus. B2B should be considered particularly for subjects whose glycemic control is poor despite PPT.Keywords: type 2 diabetes mellitus, insulin therapy, basal plus two times bolus insulin therapy, prandial premixed insulin therapy, Diabetes Treatment Satisfaction Questionnaire

  7. Effect of Cardiac Resynchronization Therapy in Patients With Insulin-Treated Diabetes Mellitus

    DEFF Research Database (Denmark)

    Szepietowska, Barbara; Kutyifa, Valentina; Ruwald, Martin H

    2015-01-01

    Diabetes mellitus (DM) modify outcome in patients with heart failure (HF). We aimed to analyze the risk for death, HF alone, combined end point HF/death, and ventricular tachycardia/ventricular fibrillation (VT/VF) in patients with mild HF without DM and in those with DM, further stratified...... branch block in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy trial. Treatment with CRT-D versus implantable cardioverter defibrillator was associated with 76% risk reduction in all-cause mortality (hazard ratio 0.24; 95% confidence interval 0.08 to 0.......74, p = 0.012) in subgroup of diabetic patients treated with insulin only (interaction p = 0.043). Significant risk reduction in HF alone, HF/death, and the VT/VF after CRT-D was observed across investigated groups and similar left ventricular reverse remodeling to CRT-D. In conclusion, patients...

  8. Comparison of liraglutide plus basal insulin and basal-bolus insulin therapy (BBIT) for glycemic control, body weight stability, and treatment satisfaction in patients treated using BBIT for type 2 diabetes without severe insulin deficiency: A randomized prospective pilot study.

    Science.gov (United States)

    Yamamoto, Saki; Hayashi, Toshiyuki; Ohara, Makoto; Goto, Satoshi; Sato, Jun; Nagaike, Hiroe; Fukase, Ayako; Sato, Nobuko; Hiromura, Munenori; Tomoyasu, Masako; Nakanishi, Noriko; Lee, Soushou; Osamura, Anna; Yamamoto, Takeshi; Fukui, Tomoyasu; Hirano, Tsutomu

    2018-03-26

    We examined whether 0.9 mg/day liraglutide plus basal insulin (Lira-basal) is superior to basal-bolus insulin therapy (BBIT) for type 2 diabetes (T2DM) without severe insulin deficiency as determined by glucagon stimulation. Fifty patients receiving BBIT were enrolled in this 24-week, prospective, randomized, open-labeled study. After excluding subjects with fasting C-peptide immunoreactivity (CPR) basal (n = 12) or continued BBIT (n = 13). Primary endpoint was change in HbA1c. Secondary endpoints were changes in body weight (BW), 7-point self-monitored blood glucose (SMBG), and Diabetes Treatment Satisfaction Questionnaire status (DTSQs) scores. The Lira-basal group demonstrated reduced HbA1c, whereas the BBIT group showed no change. BW was reduced in the Lira-basal group but increased in the BBIT group. The Lira-basal group also exhibited significantly reduced pre-breakfast and pre-lunch SMBG. DTSQs scores improved in the Lira-basal group but not the BBIT group. Plasma lipids, liver function, and kidney function were not significantly changed in either group. Lira-basal therapy is superior to BBIT for T2DM without severe insulin deficiency. This study was registered with UMIN Clinical Trials Registry (UMIN000028313). Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Insulin glargine 300 U/mL for basal insulin therapy in type 1 and type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Lau IT

    2017-06-01

    Full Text Available Ip Tim Lau,1 Ka Fai Lee,2 Wing Yee So,3 Kathryn Tan,4 Vincent Tok Fai Yeung5 1Department of Medicine, Tseung Kwan O Hospital, 2Department of Medicine and Geriatrics, Kwong Wah Hospital, 3Department of Medicine and Therapeutics, Chinese University of Hong Kong, Prince of Wales Hospital, 4Department of Medicine, Queen Mary Hospital, University of Hong Kong, 5Department of Medicine and Geriatrics, Our Lady of Maryknoll Hospital, Hong Kong, China Objective: To review published clinical studies on the efficacy and safety of new insulin glargine 300 units/mL (Gla-300, a new long-acting insulin analog, for the treatment of type 1 and type 2 diabetes mellitus (T1DM, T2DMMaterials and methods: Data sources comprised primary research articles on Gla-300, including pharmacodynamic, pharmacokinetic, and clinical studies.Results: In pharmacodynamic and pharmacokinetic studies, Gla-300 showed a flatter time–action profile and longer duration of action than Gla-100. Noninferiority of Gla-300 versus Gla-100 for lowering of glycated hemoglobin was demonstrated in Phase III clinical studies covering a range of T1DM and T2DM patient populations. Over 6–12 months of follow-up, Gla-300 consistently showed comparable glycemic efficacy with less hypoglycemia vs Gla-100, even during the first 8 weeks of treatment. Although titrated insulin doses were 11%–17% higher with Gla-300 vs Gla-100, changes in body weight were similar or favored Gla-300.Conclusion: Clinical studies provide evidence that the pharmacodynamic and pharmacokinetic properties of Gla-300 may translate into clinical benefits in both T1DM and T2DM. Gla-300 may provide a new option for people initiating basal insulin, those requiring higher basal insulin doses, those with T1DM, and those who may be at increased risk for hypoglycemia, such as people with chronic kidney disease, the elderly, and those with cardiovascular comorbidities. Keywords: diabetes mellitus, long-acting insulin, insulin glargine

  10. Insulin requirement profiles of short-term intensive insulin therapy in patients with newly diagnosed type 2 diabetes and its association with long-term glycemic remission.

    Science.gov (United States)

    Liu, Liehua; Ke, Weijian; Wan, Xuesi; Zhang, Pengyuan; Cao, Xiaopei; Deng, Wanping; Li, Yanbing

    2015-05-01

    To investigate the insulin requirement profiles during short-term intensive continuous subcutaneous insulin infusion (CSII) in patients with newly diagnosed type 2 diabetes and its relationship with long-term glycemic remission. CSII was applied in 104 patients with newly diagnosed type 2 diabetes. Daily insulin doses were titrated and recorded to achieve and maintain euglycemia for 2 weeks. Measurements of blood glucose, lipid profiles as well as intravenous glucose tolerance tests were performed before and after the therapy. Afterwards, patients were followed up for 1 year. Total daily insulin dose (TDD) was 56.6±16.1IU at the first day when euglycemia was achieved (TDD-1). Thereafter, TDD progressively decreased at a rate of 1.4±1.0IU/day to 36.2±16.5IU at the end of the therapy. TDD-1 could be estimated with body weight, FPG, triglyceride and waist circumference in a multiple linear regression model. Decrement of TDD after euglycemia was achieved (ΔTDD) was associated with reduction of HOMA-IR (r=0.27, P=0.008) but not with improvement in β cell function. Patients in the lower tertile of ΔTDD had a significantly higher risk of hyperglycemia relapse than those in the upper tertile within 1 year (HR 3.4, 95%CI [1.4, 8.4], P=0.008). There is a steady decline of TDD after euglycemia is achieved in patients with newly diagnosed type 2 diabetes treated with CSII, and ΔTDD is associated with a better long-term glycemic outcome. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. [Ultrasonographic evaluation of selected parameters of the endothelial function in brachial arteries and IMT measurements in carotid arteries in children with diabetes type 1 using personal insulin pumps--preliminary report].

    Science.gov (United States)

    Tołwińska, Joanna; Głowińska-Olszewska, Barbara; Urban, Mirosława; Florys, Bozena; Peczyńska, Jadwiga

    2006-01-01

    Type 1 diabetes is a known risk factor for arterial atherosclerosis. The first symptoms can be found even in childhood. The ultrasonographic measurements of intimal plus medial thickness in carotid arteries (IMT) and flow mediated dilatation (FMD) evaluated in brachial arteries, play a known role in the detection in these cases. The diabetes treatment intensification is an important factor in delaying early atherosclerotic changes. Currently, intensive treatment of children's diabetes with use of continuous subcutaneous insulin infusion with personal insulin pumps is gaining more and more popularity. THE AIM OF THIS STUDY was the evaluation of IMT and FMD indexes in children suffering from type 1 diabetes in the context of treatment intensification (multidose insulin injections v. personal insulin pumps). We examined 64 children (29 boys and 35 girls) in the mean age 15.5 years treated with the multidose insulin injections method and 10 children using personal insulin pumps (4 girls and 6 boys) in the mean age 14.5 years. Using high resolution ultrasonography we evaluated IMT values in carotid arteries and FMD parameters in brachial arteries. In our analysis we estimated the blood concentration of lipid parameters, values of systolic and diastolic blood pressure, the age of diabetes onset, duration time of the illness and the values of HbA1c as a marker of metabolic control. We noticed significantly higher FMD values in patients treated with personal insulin pumps (13.7 vs. 5.5%, p=0.001). IMT values were similar in both groups (0.52 vs. 0.5 mm, p=0. 41). The level of HDL cholesterol was higher and triglycerides lower in the group with treatment intensification. The metabolic control was the same in both groups. In patients treated by the multidose insulin injections IMT correlated with systolic blood pressure values. We didn't notice any correlation between IMT and FMD in any group. 1. Treatment intensification (personal insulin pumps) influences better vascular

  12. Short-term intensive insulin therapy in type 2 diabetes mellitus: a systematic review and meta-analysis.

    Science.gov (United States)

    Kramer, Caroline Kaercher; Zinman, Bernard; Retnakaran, Ravi

    2013-09-01

    Studies have shown that, when implemented early in the course of type 2 diabetes mellitus, treatment with intensive insulin therapy for 2-3 weeks can induce a glycaemic remission, wherein patients are able to maintain normoglycaemia without any anti-diabetic medication. We thus did a systematic review and meta-analysis of interventional studies to assess the effect of short-term intensive insulin therapy on the pathophysiological defects underlying type 2 diabetes mellitus (pancreatic β-cell dysfunction and insulin resistance) and identify clinical predictors of remission. We identified studies published between 1950 and Nov 19, 2012, which assessed the effect of intensive insulin therapy on β-cell function or insulin resistance, or both, or assessed long-term drug-free glycaemic remission in adults aged 18 years or older with newly diagnosed type 2 diabetes mellitus. We calculated pooled estimates by random-effects model. This study is registered with International Prospective Register of Systematic Reviews, number CRD42012002829. We identified 1645 studies of which seven fulfilled inclusion criteria (n=839 participants). Five studies were non-randomised. A pooled analysis of the seven studies showed a post-intensive insulin therapy increase in Homeostasis Model Assessment of β-cell function as compared with baseline (1·13, 95% CI 1·02 to 1·25) and a decrease in Homeostasis Model Assessment of Insulin Resistance (-0·57, -0·84 to -0·29). In the four studies that assessed glycaemic remission (n=559 participants), the proportion of participants in drug-free remission was about 66·2% (292 of 441 patients) after 3 months of follow-up, about 58·9% (222 of 377 patients) after 6 months, about 46·3% (229 of 495 patients) after 12 months, and about 42·1% (53 of 126 patients) after 24 months. Patients who achieved remission had higher body-mass index than those who did not achieve remission (1·06 kg/m(2), 95% CI 0·55 to 1·58) and lower fasting plasma glucose

  13. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    Science.gov (United States)

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  14. Effects of Vildagliptin Add-on Insulin Therapy on Nocturnal Glycemic Variations in Uncontrolled Type 2 Diabetes.

    Science.gov (United States)

    Li, Feng-Fei; Shen, Yun; Sun, Rui; Zhang, Dan-Feng; Jin, Xing; Zhai, Xiao-Fang; Chen, Mao-Yuan; Su, Xiao-Fei; Wu, Jin-Dan; Ye, Lei; Ma, Jian-Hua

    2017-10-01

    To investigate whether vildagliptin add-on insulin therapy improves glycemic variations in patients with uncontrolled type 2 diabetes (T2D) compared to patients with placebo therapy. This was a 24-week, single-center, double-blind, placebo-controlled trial. Inadequately controlled T2D patients treated with insulin therapy were recruited between June 2012 and April 2013. The trial included a 2-week screening period and a 24-week randomized period. Subjects were randomly assigned to a vildagliptin add-on insulin therapy group (n = 17) or a matched placebo group (n = 16). Scheduled visits occurred at weeks 4, 8, 12, 16, 20, and 24. Continuous glucose monitoring (CGM) was performed before and at the endpoint of the study. A total of 33 subjects were admitted, with 1 patient withdrawing from the placebo group. After 24 weeks of therapy, HbA1c values were significantly reduced at the endpoint in the vildagliptin add-on group. CGM data showed that patients with vildagliptin add-on therapy had a significantly lower 24-h mean glucose concentration and mean amplitude of glycemic excursion (MAGE). At the endpoint of the study, patients in the vildagliptin add-on group had a significantly lower MAGE and standard deviation compared to the control patients during the nocturnal period (0000-0600). A severe hypoglycemic episode was not observed in either group. Vildagliptin add-on therapy to insulin has the ability to improve glycemic variations, especially during the nocturnal time period, in patients with uncontrolled T2D.

  15. Cross-sectional study into quality of life issues surrounding insulin pump use in type 1 diabetes

    DEFF Research Database (Denmark)

    Barnard, Katharine D.; Skinner, T. Chas

    2008-01-01

    This study aimed to determine whether continuous subcutaneous insulin infusion (CSII) is associated with improved quality of life (QoL) in routine care in the UK. We conducted a multiple cohort survey study of individuals with type 1 diabetes (matched for age, gender and frequency of blood glucose......-economic environment, individuals using CSII reported better QoL than a matched cohort of individuals managing their diabetes using MDI....

  16. Severe hypoglycemia rates and associated costs among type 2 diabetics starting basal insulin therapy in the United States.

    Science.gov (United States)

    Ganz, Michael L; Wintfeld, Neil S; Li, Qian; Lee, Yuan-Chi; Gatt, Elyse; Huang, Joanna C

    2014-10-01

    To derive current real-world data on the rates and costs of severe hypoglycemia (SH) for people with type 2 diabetes mellitus (T2D) who have initiated basal insulin therapy and to examine differences in SH rates and costs stratified by history of prior SH events. We used a nation-wide electronic health records database that included encounter and laboratory data, as well as clinical notes, to estimate the rates and costs of SH events among adults with T2D who initiated basal insulin between 2008 and 2011. Unadjusted and regression-adjusted rates and quarterly costs were calculated for all patients as well as stratified by history of a SH event before starting basal insulin and history of a SH event during the basal insulin titration period. We identified 7235 incident cases of basal insulin use among patients with T2D who did not use insulin during the previous 12 months. Regression-adjusted incidence and total event rates were 10.36 and 11.21 per 100 patient-years, respectively. A history of SH events during the pre-index baseline and post-index titration periods were statistically significantly associated with both the incidence and total event rates (p history of previous SH or SH events during the titration period were not statistically significantly associated with costs. These results suggest that the real-world burden of SH is high among people with T2D who start using basal insulin and that history of previous SH events, both before starting insulin and during the insulin titration period, influences future SH. These results can also provide insights into interventions that can prevent or delay SH. These results should, however, be interpreted in light of the key limitations of our study: not all SH events may have been captured or coded in the database, data on filled prescriptions were not available, and the post-titration follow-up period could have been divided into time units other than quarters (3 month blocks) resulting in potentially different

  17. Effects of Hormone Replacement Therapy on Insulin Resistance in Postmenopausal Diabetic Women

    Directory of Open Access Journals (Sweden)

    Iskra Bitoska

    2016-02-01

    CONCLUSION: HRT was associated with statistically signifficant increase of insulin sensitivity. Larger clinical trials will be necessary to understand whether HRT may improve insulin resistance and glucose homeostasis in women with diabetes, especially when given shortly after entering menopause.

  18. Skeletal Muscle Sorbitol Levels in Diabetic Rats with and without Insulin Therapy and Endurance Exercise Training

    Science.gov (United States)

    Sánchez, O. A.; Walseth, T. F.; Snow, L. M.; Serfass, R. C.; Thompson, L. V.

    2009-01-01

    Sorbitol accumulation is postulated to play a role in skeletal muscle dysfunction associated with diabetes. The purpose of this study was to determine the effects of insulin and of endurance exercise on skeletal muscle sorbitol levels in streptozotocin-induced diabetic rats. Rats were assigned to one experimental group (control sedentary, control exercise, diabetic sedentary, diabetic exercise, diabetic sedentary no-insulin). Diabetic rats received daily subcutaneous insulin. The exercise-trained rats ran on a treadmill (1 hour, 5X/wk, for 12 weeks). Skeletal muscle sorbitol levels were the highest in the diabetic sedentary no-insulin group. Diabetic sedentary rats receiving insulin had similar sorbitol levels to control sedentary rats. Endurance exercise did not significantly affect sorbitol levels. These results indicate that insulin treatment lowers sorbitol in skeletal muscle; therefore sorbitol accumulation is probably not related to muscle dysfunction in insulin-treated diabetic individuals. Endurance exercise did not influence intramuscular sorbitol values as strongly as insulin. PMID:20016800

  19. Efficacy and safety comparison between liraglutide as add-on therapy to insulin and insulin dose-increase in Chinese subjects with poorly controlled type 2 diabetes and abdominal obesity

    Directory of Open Access Journals (Sweden)

    Li Chun-jun

    2012-11-01

    Full Text Available Abstract Objective To assess the efficacy and safety of adding liraglutide to established insulin therapy in poorly controlled Chinese subjects with type 2 diabetes and abdominal obesity compared with increasing insulin dose. Methods A 12-week, randomized, parallel-group study was carried out. A total of 84 patients completed the trial who had been randomly assigned to either the liraglutide-added group or the insulin-increasing group while continuing current insulin based treatment. Insulin dose was reduced by 0-30% upon the initiation of liraglutide. Insulin doses were subsequently adjusted to optimized glycemic control. Glycosylated hemoglobin (HbA1c values, blood glucose, total daily insulin dose, body weight, waist circumference, and the number of hypoglycemic events and adverse events were evaluated. Results At the end of study, the mean reduction in HbA1c between the liraglutide-added group and the insulin-increasing group was not significantly different (1.9% vs. 1.77%, p>0.05. However, the percentage of subjects reaching the composite endpoint of HbA1c ≤ 7.0% with no weight gain and no hypoglycemia, was significantly higher in the liraglutide-added group than in the insulin-increasing group (67% vs. 19%, p2, p Conclusions Addition of liraglutide to abdominally obese, insulin-treated patients led to improvement in glycemic control similar to that achieved by increasing insulin dosage, but with a lower daily dose of insulin and fewer hypoglycemic events. Adding liraglutide to insulin also induced a significant reduction in body weight and waist circumference. Liraglutide combined with insulin may be the best treatment option for poorly controlled type 2 diabetes and abdominal obesity.

  20. Endurance training improves insulin sensitivity and body composition in prostate cancer patients treated with androgen deprivation therapy

    DEFF Research Database (Denmark)

    Hvid, Thine; Winding, Kamilla; Rinnov, Anders

    2013-01-01

    Insulin resistance and changes in body composition are side effects of androgen deprivation therapy (ADT) given to prostate cancer patients. The present study investigated whether endurance training improves insulin sensitivity and body composition in ADT-treated prostate cancer patients. Nine me...... and magnetic resonance imaging). The secondary endpoint was systemic inflammation. Statistical analysis was carried out using two-way ANOVA. Endurance training increased VO2max (ml(O2)/min per kg) by 11 and 13% in the patients and controls respectively (P...

  1. Sub-acute insulin therapy does not affect long-term visiospatial ...

    African Journals Online (AJOL)

    Insulin is a common hypoglycaemic agent used to treat diabetes, but it has also been reported to exert other effects on the body including modulation cognition. Reported findings on insulin effect on learning and memory are scanty and often conflicting. This study was aimed at evaluating the effect of sub-acute insulin ...

  2. Sleep architecture, insulin resistance and the nasal cycle: Implications for positive airway pressure therapy

    Directory of Open Access Journals (Sweden)

    Catherine A.P. Crofts

    2018-03-01

    Full Text Available Background: The global pandemic of metabolic disease is worsening. The metabolic theory of obesity proposes that hormonal changes, especially hyperinsulinaemia, precede metabolic disease development. Although quality sleep is recognised as a key factor for good health, less is known about disrupted sleep as a risk factor for hyperinsulinaemia.   Aim: To explore the relationship between sleep, especially sleep architecture and the nasal cycle, on insulin secretion in obstructive sleep apnoea (OSA with comorbid metabolic disease. This review includes a discussion of the potential role of Rest-Activity-Cycler positive airway pressure (RACer-PAP, a novel non-pharmacological OSA treatment strategy.   Methods: A narrative review of all the relevant papers known to the authors was conducted. This review also included results from a polysomnographic sleep clinic pilot study (n = 3 comparing sleep efficiency of RACer-PAP to nasal continuous positive airways pressure (n-CPAP in OSA patients.   Results: Metabolic disease is strongly associated with disturbed sleep. Sleep architecture influences cerebral hormonal secretion, lateral shifts in the autonomic nervous system and nasal airflow dominance. Disturbed sleep shortens short-wave sleep periods, decreasing insulin sensitivity and glucose tolerance. Improvements to metabolic function during n-CPAP treatment are inconsistent. If RACer-PAP demonstrates superior effects on sleep architecture and autonomic function, it may offer advantages in OSA patients with comorbid metabolic disease.   Conclusion: Improving sleep architecture by maintaining the nasal cycle proposes a novel non-pharmacological treatment paradigm for treating OSA with comorbid metabolic disease. Research is required to demonstrate if RACer-PAP therapy influences whole night sleep architecture, sympathovagal balance and markers of metabolic disease.

  3. Use and Effectiveness of Continuous Subcutaneous Insulin Infusion (CSII) and Multiple Daily Insulin Injection Therapy (MIT) in Children, Adolescents and Young Adults with Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Schiel, R; Burgard, D; Perenthaler, T; Stein, G; Kramer, G; Steveling, A

    2016-02-01

    Today continuous subcutaneous insulin infusion (CSII) is frequently used in children and adolescents with type 1 diabetes mellitus. The present cross-sectional trial aimed to document current practice, quality of diabetes control and incidence of acute complications in different age-groups under CSII vs. multiple daily insulin injection therapy (MIT). Moreover the survey analyzed socio-demographic backgrounds of the patients. A total of 901 patients (age 11.5±4.0, diabetes duration 4.0±3.6 years) was entered in the database. Clinical data, laboratory parameters and, using a standardized questionnaire, socio-demographic data were assessed. For age-related analyses patients were allocated to 4 groups: pre-school children (MIT. Patients with CSII vs. MIT had a longer diabetes duration, they used more frequently insulin analogues, performed more frequently blood-glucose self-tests and had a lower insulin dosage per kilogram body weight. In respect of HbA1c, the mean amplitude of blood-glucose excursions, but also of lipids, creatinine, microalbuminuria and blood pressure, there were no differences in neither age-group between patients with CSII and MIT. In patients with CSII and MIT, there was a tendency (pMIT there is an increase of HbA1c towards adolescence. It must also highlighted that CSII seems to be expansive and that CSII is more frequently used in patients with better educational levels and deriving from higher social classes. © Georg Thieme Verlag KG Stuttgart · New York.

  4. [Attitudes toward insulin prescription in type 2 diabetic patients non-compliant with diet therapy].

    Science.gov (United States)

    Mordenti, F; D'Angiolini, G; Murgia, F

    2000-01-01

    Investigate the compliance of type 2 diabetic patients with the prescription of insulin according to pre-existing ideas on insulin, and to personality traits. Twenty insulin-treated type 2 diabetic patients were selected on the basis of previous scarce compliance with diet and exercise and BMI > 28 kg/m2. The patients' attitudes toward insulin prescription were evaluated with a semi-structured interview and personality traits were evaluated with the ACL test(Adjective Check List). When insulin was first prescribed to these patients, 65% accepted immediately. However, 45% answered that their acquiescence to insulin treatment was accompanied by doubts or apprehension. The fear of insulin dependence was shared by 50%, with a much greater prevalence among those who resisted to insulin treatment (86% vs 31%) and those who recalled doubts and fears about insulin (73% vs 22%). Patients with a fear of dependence differed significantly from the others in five personality scales: greater opposition and ambiguity, less self-confidence, more inflexible, less demanding of others and more inclined to bargain. The irrational fear of dependence may, therefore, play a role in both the manifest acceptance/rejection of insulin and non-expressed doubts, and may in turn be influenced by personality traits. Specific patient education on insulin treatment in type 2 diabetes is necessary, and should be planned according to the personality factors that may influence the perception of facts and the patients' motivation.

  5. Role of Acid and Weakly Acidic Reflux in Gastroesophageal Reflux Disease Off Proton Pump Inhibitor Therapy

    Science.gov (United States)

    Sung, Hea Jung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-01-01

    Background/Aims Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. Methods We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Results Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. Conclusions In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus. PMID:22837877

  6. Role of Acid and weakly acidic reflux in gastroesophageal reflux disease off proton pump inhibitor therapy.

    Science.gov (United States)

    Sung, Hea Jung; Cho, Yu Kyung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-07-01

    Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [Acid reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus.

  7. Attenuation of Ca2+ homeostasis, oxidative stress, and mitochondrial dysfunctions in diabetic rat heart: insulin therapy or aerobic exercise?

    Science.gov (United States)

    da Silva, Márcia F; Natali, Antônio J; da Silva, Edson; Gomes, Gilton J; Teodoro, Bruno G; Cunha, Daise N Q; Drummond, Lucas R; Drummond, Filipe R; Moura, Anselmo G; Belfort, Felipe G; de Oliveira, Alessandro; Maldonado, Izabel R S C; Alberici, Luciane C

    2015-07-15

    We tested the effects of swimming training and insulin therapy, either alone or in combination, on the intracellular calcium ([Ca(2+)]i) homeostasis, oxidative stress, and mitochondrial functions in diabetic rat hearts. Male Wistar rats were separated into control, diabetic, or diabetic plus insulin groups. Type 1 diabetes mellitus was induced by streptozotocin (STZ). Insulin-treated groups received 1 to 4 UI of insulin daily for 8 wk. Each group was divided into sedentary or exercised rats. Trained groups were submitted to swimming (90 min/day, 5 days/wk, 8 wk). [Ca(2+)]i transient in left ventricular myocytes (LVM), oxidative stress in LV tissue, and mitochondrial functions in the heart were assessed. Diabetes reduced the amplitude and prolonged the times to peak and to half decay of the [Ca(2+)]i transient in LVM, increased NADPH oxidase-4 (Nox-4) expression, decreased superoxide dismutase (SOD), and increased carbonyl protein contents in LV tissue. In isolated mitochondria, diabetes increased Ca(2+) uptake, susceptibility to permeability transition pore (MPTP) opening, uncoupling protein-2 (UCP-2) expression, and oxygen consumption but reduced H2O2 release. Swimming training corrected the time course of the [Ca(2+)]i transient, UCP-2 expression, and mitochondrial Ca(2+) uptake. Insulin replacement further normalized [Ca(2+)]i transient amplitude, Nox-4 expression, and carbonyl content. Alongside these benefits, the combination of both therapies restored the LV tissue SOD and mitochondrial O2 consumption, H2O2 release, and MPTP opening. In conclusion, the combination of swimming training with insulin replacement was more effective in attenuating intracellular Ca(2+) disruptions, oxidative stress, and mitochondrial dysfunctions in STZ-induced diabetic rat hearts. Copyright © 2015 the American Physiological Society.

  8. Effects of insulin therapy on weight gain and fat distribution in the HF/HS-STZ rat model of type 2 diabetes

    DEFF Research Database (Denmark)

    Skovsø, Søs; Damgaard, J; Fels, J J

    2015-01-01

    insulin on fat distribution in the high-fat/high-sucrose fed rat treated with streptozotocin (HF/HS-STZ) rat model of type 2 diabetes. We also examined effects of insulin therapy on circulating CVD markers, including adiponectin, triglycerides (TGs), total cholesterol and high-density lipoprotein......-density lipoprotein (HDL) and adiponectin levels were elevated (Ptype 2 diabetes, we find that insulin therapy modulates fat distribution. Specifically, our data show that insulin has a relatively positive effect on CVD-associated parameters......BACKGROUND/OBJECTIVES: Insulin therapy is required for many patients with the obesity-related disorder type 2 diabetes, but is also associated with weight gain. The specific location of adipose tissue location matters to cardiovascular disease (CVD) risk. We investigated effects of exogenous...

  9. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  10. Long-term efficacy and safety of vildagliptin add-on therapy in type 2 diabetes mellitus with insulin treatment.

    Science.gov (United States)

    Kanazawa, Ippei; Tanaka, Ken-Ichiro; Notsu, Masakazu; Tanaka, Sayuri; Kiyohara, Nobuaki; Koike, Sayo; Yamane, Yuko; Tada, Yuko; Sasaki, Motofumi; Yamauchi, Mika; Sugimoto, Toshitsugu

    2017-01-01

    The use of dipeptidyl peptidase (DPP)-4 inhibitors in patients with type 2 diabetes treated with insulin may be beneficial. However, the long-term efficacy and safety of vildagliptin add-on therapy in these patients remains unclear. A total of 73 patients with type 2 diabetes treated with insulin were randomly assigned to receive either add-on therapy of vildagliptin (n=37) or conventional therapy without DPP-4 inhibitors (n=36) for glucose control. Hemoglobin A1c (HbA1c) levels, dose and number of insulin injections, number of hypoglycemia episodes, and liver and renal function were monitored for 2years. The baseline characteristics of subjects, including age, dose of insulin injections, or HbA1c levels, did not differ between the two groups. In the vildagliptin group, HbA1c levels significantly decreased and the significance of HbA1c reduction was maintained for 24months (from 8.0±1.2% to 7.4±1.0%, pinsulin injections significantly reduced (-5.6units, p1, and -0.9 times, p1). However, these parameters were unchanged in the control group. The number of patients who experienced three or more episodes of hypoglycemia per year was significantly lower in the vildagliptin group (n=4) than in the control group (n=11) (odds ratio, 0.28; 95% confidence interval, 0.08-0.97; pinsulin treatment for 24months was well tolerated and led to sustained reductions in HbA1c, the dose and number of insulin injections, and the risk of hypoglycemia. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Twenty-four-hour simultaneous subcutaneous basal-bolus administration of insulin and amylin in adolescents with type 1 diabetes decreases postprandial hyperglycemia

    Science.gov (United States)

    The purpose of this study was to examine the effect of continuous subcutaneous (sc) replacement of amylin and insulin for a 24-h period on glucose homeostasis in adolescents with type 1 diabetes. Thirteen adolescents with type 1 diabetes on insulin pump therapy participated in a randomized, controll...

  12. The effect of 30 months of low-dose replacement therapy with recombinant human growth hormone (rhGH) on insulin and C-peptide kinetics, insulin secretion, insulin sensitivity, glucose effectiveness, and body composition in GH-deficient adults

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Maghsoudi, S; Fisker, S

    2000-01-01

    The aim of the present study was to evaluate the long-term (30 months) metabolic effects of recombinant human GH (rhGH) given in a mean dose of 6.7 microg/kg x day (= 1.6 IU/day), in 11 patients with adult GH deficiency. Glucose metabolism was evaluated by an oral glucose tolerance test and an iv...... (frequently sampled iv glucose tolerance test) glucose tolerance test, and body composition was estimated by dual-energy x-ray absorptiometry. Treatment with rhGH induced persistent favorable changes in body composition, with a 10% increase in lean body mass (P ... in glucose tolerance, beta-cell response was still inappropriate. Our conclusion is that long-term rhGH-replacement therapy in GH deficiency adults induced a significant deterioration in glucose tolerance, profound changes in kinetics of C-peptide, and insulin and prehepatic insulin secretion, despite...

  13. Effects of switching from prandial premixed insulin therapy to basal plus two times bolus insulin therapy on glycemic control and quality of life in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Ito, Hiroyuki; Abe, Mariko; Antoku, Shinichi; Omoto, Takashi; Shinozaki, Masahiro; Nishio, Shinya; Mifune, Mizuo; Togane, Michiko

    2014-01-01

    The effects of switching from prandial premixed insulin therapy (PPT) injected three times a day to basal plus two times bolus insulin therapy (B2B) on glycemic control and quality of life were investigated in patients with type 2 diabetes mellitus. The clinical course was prospectively observed during the first 16 weeks after switching to B2B (insulin glargine plus insulin glulisine before breakfast and dinner) in 27 subjects previously treated with PPT using 50/50 premixed insulin. The Diabetes Treatment Satisfaction Questionnaire (DTSQ) was administered at the start and end of the study. The glycated hemoglobin (HbA1c) level (8.3% ± 1.8% to 8.2% ± 1.1%) and the DTSQ score did not change between the start and end of the study. An improvement in HbA1c level was found in nine (33%) subjects. The change in HbA1c showed a significant negative correlation with baseline HbA1c, and was significantly better in patients with a baseline HbA1c >8.0% than in those with an HbA1c ≤ 8.0% (-0.9 ± 2.0 versus 0.3 ± 0.6, respectively, P = 0.02). The change in DTSQ score representing treatment satisfaction was significantly greater in patients whose HbA1c level was improved than in those in whom it was not (2.7 ± 3.6 versus -0.8 ± 3.5, P = 0.04). B2B was noninferior to PPT with regard to HbA1c levels in patients with type 2 diabetes mellitus. B2B should be considered particularly for subjects whose glycemic control is poor despite PPT.

  14. Stimulation by ATP of proinsulin to insulin conversion in isolated rat pancreatic islet secretory granules. Association with the ATP-dependent proton pump

    International Nuclear Information System (INIS)

    Rhodes, C.J.; Lucas, C.A.; Mutkoski, R.L.; Orci, L.; Halban, P.A.

    1987-01-01

    Isolated rat pancreatic islets were pulse-labeled for 5 min with [ 3 H]leucine then chased for 25 min, during which time endogenously labeled [ 3 H]proinsulin becomes predominantly compartmented in immature secretory granules. The islets were then homogenized in isotonic sucrose (pH 7.4) and a beta-granule preparation obtained by differential centrifugation and discontinuous sucrose gradient ultracentrifugation. This preparation was enriched 8-fold in beta-granules. Aside from contamination with mitochondria and a limited number of lysosomes, the beta-granule preparation was essentially free of any other organelles involved in proinsulin synthesis and packaging (i.e. microsomal elements and, more particularly, Golgi complex). Conversion of endogenously labeled [ 3 H]proinsulin was followed in this beta-granule fraction for up to 2 h at 37 degrees C in a buffer (pH 7.3) that mimicked the cationic constituents of B-cell cytosol, during which time 92% of the beta-granules remained intact. Proinsulin conversion was analyzed by high performance liquid chromatography. The rate of proinsulin conversion to insulin was stimulated by 2.2 +/- 0.1-fold (n = 6) (at a 60-min incubation) in the presence of ATP (2 mM) and an ATP regenerating system compared to beta-granule preparations incubated without ATP. This ATP stimulation was abolished in the presence of beta-granule proton pump ATPase inhibitors (tributyltin, 2.5 microM, or 1,3-dicyclohexylcarbodiimide, 50 microM). Inhibitors of mitochondrial proton pump ATPases had no effect on the ATP stimulation of proinsulin conversion. When granules were incubated in a more acidic buffer, proinsulin conversion was increased relative to that at pH 7.3. At pH 5.5, ATP no longer stimulated conversion, and tributyltin and 1,3-dicyclohexylcarbodiimide had no effect

  15. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  16. Reliability and Validity of Modified Service Quality Instrument (SERVQUAL) in Patients' Motivation to Adhere to Insulin Therapy.

    Science.gov (United States)

    Jakupovic, Vedran; Solakovic, Suajb; Celebic, Nedim; Kulovic, Dzenan

    2018-03-01

    Diabetes is progressive condition which requires various ways of treatment. Adequate therapy prescribed in the right time helps patient to postpone development of complications. Adherence to complicated therapy is challenge for both patients and HCPs and is subject of research in many disciplines. Improvement in communication between HCP and patients is very important in patient's adherence to therapy. Aim of this research was to explore validity and reliability of modified SERVQUAL instrument in attempt to explore ways of motivating diabetic patient to accept prescribed insulin therapy. We used modified SERVQUAL questionnaire as instrument in the research. It was necessary to check validity and reliability of the new modified instrument. Results show that modified Servqual instrument has excellent reliability (α=0.908), so we could say that it measures precisely Expectations, Perceptions and Motivation at patients. Factor analysis (EFA method) with Varimax rotation extracted 4 factors which together explain 52.902% variance of the results on this subscale. Bifactorial solution could be seen on Scree-plot diagram (break at second factor). Results in this research show that modified Servqual instrument which is created in order to measure expectations and perceptions of the patients is valid and reliable. Reliability and validity are proven indeed in additional dimension which was created originally for this research - motivation to accept insulin therapy.

  17. Reliability and Validity of Modified Service Quality Instrument (SERVQUAL) in Patients’ Motivation to Adhere to Insulin Therapy

    Science.gov (United States)

    Jakupovic, Vedran; Solakovic, Suajb; Celebic, Nedim; Kulovic, Dzenan

    2018-01-01

    Introduction: Diabetes is progressive condition which requires various ways of treatment. Adequate therapy prescribed in the right time helps patient to postpone development of complications. Adherence to complicated therapy is challenge for both patients and HCPs and is subject of research in many disciplines. Improvement in communication between HCP and patients is very important in patient’s adherence to therapy. Aim: Aim of this research was to explore validity and reliability of modified SERVQUAL instrument in attempt to explore ways of motivating diabetic patient to accept prescribed insulin therapy. Material and Methods: We used modified SERVQUAL questionnaire as instrument in the research. It was necessary to check validity and reliability of the new modified instrument. Results: Results show that modified Servqual instrument has excellent reliability (α=0.908), so we could say that it measures precisely Expectations, Perceptions and Motivation at patients. Factor analysis (EFA method) with Varimax rotation extracted 4 factors which together explain 52.902% variance of the results on this subscale. Bifactorial solution could be seen on Scree-plot diagram (break at second factor). Conclusion: Results in this research show that modified Servqual instrument which is created in order to measure expectations and perceptions of the patients is valid and reliable. Reliability and validity are proven indeed in additional dimension which was created originally for this research - motivation to accept insulin therapy. PMID:29670478

  18. Consideration of Insulin Pumps or Continuous Glucose Monitors by Adolescents With Type 1 Diabetes and Their Parents: Stakeholder Engagement in the Design of Web-Based Decision Aids.

    Science.gov (United States)

    Wysocki, Tim; Hirschfeld, Fiona; Miller, Louis; Izenberg, Neil; Dowshen, Steven A; Taylor, Alex; Milkes, Amy; Shinseki, Michelle T; Bejarano, Carolina; Kozikowski, Chelsea; Kowal, Karen; Starr-Ashton, Penny; Ross, Judith L; Kummer, Mark; Carakushansky, Mauri; Lyness, D'Arcy; Brinkman, William; Pierce, Jessica; Fiks, Alexander; Christofferson, Jennifer; Rafalko, Jessica; Lawson, Margaret L

    2016-08-01

    This article describes the stakeholder-driven design, development, and testing of web-based, multimedia decision aids for youth with type 1 diabetes who are considering the insulin pump or continuous glucose monitoring and their parents. This is the initial phase of work designed to develop and evaluate the efficacy of these decision aids in promoting improved decision-making engagement with use of a selected device. Qualitative interviews of 36 parents and adolescents who had previously faced these decisions and 12 health care providers defined the content, format and structure of the decision aids. Experts in children's health media helped the research team to plan, create, and refine multimedia content and its presentation. A web development firm helped organize the content into a user-friendly interface and enabled tracking of decision aid utilization. Throughout, members of the research team, adolescents, parents, and 3 expert consultants offered perspectives about the website content, structure, and function until the design was complete. With the decision aid websites completed, the next phase of the project is a randomized controlled trial of usual clinical practice alone or augmented by use of the decision aid websites. Stakeholder-driven development of multimedia, web-based decision aids requires meticulous attention to detail but can yield exceptional resources for adolescents and parents contemplating major changes to their diabetes regimens. © 2016 The Author(s).

  19. Young people with type 1 diabetes mellitus: Attitudes, perceptions, and experiences of diabetes management and continuous subcutaneous insulin infusion therapy.

    Science.gov (United States)

    Perry, Lin; James, Steven; Steinbeck, Katharine; Dunbabin, Janet; Lowe, Julia

    2017-06-01

    Continuous subcutaneous insulin infusion (CSII; insulin pump) use is increasing. However, there is little information about how this technology is used compared with other insulin delivery methods (ie, injections) by young people with type 1 diabetes mellitus in Australia. This study explored young people's attitudes, perceptions, and experiences with diabetes management comparing those using with those not using CSII, and proportions likely to transition to adult services requiring initiation and/or support for CSII use. A survey was undertaken of young people (aged 12 to 18 years) with type 1 diabetes mellitus and their parents/guardians living in Hunter New England, Australia, using a questionnaire designed to collect quantitative, descriptive, and demographic data. Most questions were based on previously developed and validated instruments. In total, 107 respondents returned partially or fully completed questionnaires. Respondents had positive attitudes and perceptions of their self-efficacy and diabetes management, but were moderately disturbed by their diabetes and reported experiencing suboptimal management outcomes. Patterns of associations were demonstrated between knowledge, attitudes, and experiences of diabetes modeled by regression analysis. There were no statistically significant differences in responses between users and nonusers of CSII. Over 40% indicated their intention to use the technology as adults. Opportunities for enhanced diabetes service support were clear, and CSII did not appear to be used to its full potential. Service redesign could enhance support for this young population using all preferred insulin delivery methods and should align to patients' goals and preferences to maximize service and patient gain. © 2017 John Wiley & Sons, Ltd.

  20. Social, Organizational, and Contextual Characteristics of Clinical Decision Support Systems for Intensive Insulin Therapy: A Literature Review and Case Study

    Science.gov (United States)

    Campion, Thomas R.; Waitman, Lemuel R.; May, Addison K.; Ozdas, Asli; Lorenzi, Nancy M.; Gadd, Cynthia S.

    2009-01-01

    Introduction: Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. Results: This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Discussion: Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. Conclusion: This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. PMID:19815452

  1. Social, organizational, and contextual characteristics of clinical decision support systems for intensive insulin therapy: a literature review and case study.

    Science.gov (United States)

    Campion, Thomas R; Waitman, Lemuel R; May, Addison K; Ozdas, Asli; Lorenzi, Nancy M; Gadd, Cynthia S

    2010-01-01

    Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. Copyright (c) 2009. Published by Elsevier Ireland Ltd.

  2. The efficacy of therapy with DPP-4 inhibitors combined with insulin in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Alexander Sergeevich Ametov

    2011-12-01

    Full Text Available Recently, researchers started to pay increasingly more attention to the role of gastrointestinal hormones in regulation of insulin secretion, i.e. glucosehomeostasis. To-day, there are two approaches to the treatment of DM based on the use of GLP-1 effects. One takes advantage of DPP-4 inhibitorsthe other is combination of these agents with various drugs necessitated by heterogeneity of pathophysiological factors responsible for the developmentof DM2. The latter approach ensures multiple therapeutic effects on DM2 and its complications. Many on-going studies are focused on the use ofcombination of DPP-4 inhibitors and insulin. Vildagliptin (Galvus, Novartis Pharma, Switzerland is presently the sole DPP-4 inhibitor approvedfor application with insulin in Russia.Aim. To estimate the efficacy and safety of DPP-4 inhibitor combined with long-acting insulin in the treatment of DM2. Materials and methods. The study group included 18 patients (2 men and 16 women with DM2 treated with long-acting insulin (glargine, humulinNPH for at least 3 months at a mean daily dose of 31.96?4.95 U. The age of the patients averaged 59.9?2.84 years (46-75, DM2 duration8.9?1.18 years (2-15. Parameters of comprehensive glycemic control (FG, PPG, HbA1c, LMWH - low-molecular weight heparins CGM-continuousglucose monitoring were measured using a CGMS system in the beginning and end of the study. Functional activity of pancreatic betbeta-cells and insulinresistance (HOMA-IR, lipid metabolism, and anthropometric characteristics were estimated. Results. Combined therapy resulted in positive dynamics of carbohydrate metabolism within 12 weeks after onset. The functional activity of pancreaticbetbeta-cells significantly (by 157.96 U improved by the end of the study. Changes of HOMA-IR were insignificant. CGM showed that prescription ofvildagliptin to the patients who failed to reach compensation of DM2 with long-acting insulin alone significantly improved glycemic control

  3. Endurance training improves insulin sensitivity and body composition in prostate cancer patients treated with androgen deprivation therapy.

    Science.gov (United States)

    Hvid, Thine; Winding, Kamilla; Rinnov, Anders; Dejgaard, Thomas; Thomsen, Carsten; Iversen, Peter; Brasso, Klaus; Mikines, Kari J; van Hall, Gerrit; Lindegaard, Birgitte; Solomon, Thomas P J; Pedersen, Bente K

    2013-10-01

    Insulin resistance and changes in body composition are side effects of androgen deprivation therapy (ADT) given to prostate cancer patients. The present study investigated whether endurance training improves insulin sensitivity and body composition in ADT-treated prostate cancer patients. Nine men undergoing ADT for prostate cancer and ten healthy men with normal testosterone levels underwent 12 weeks of endurance training. Primary endpoints were insulin sensitivity (euglycemic-hyperinsulinemic clamps with concomitant glucose-tracer infusion) and body composition (dual-energy X-ray absorptiometry and magnetic resonance imaging). The secondary endpoint was systemic inflammation. Statistical analysis was carried out using two-way ANOVA. Endurance training increased VO2max (ml(O2)/min per kg) by 11 and 13% in the patients and controls respectively (PBody weight (Pbody fat mass (FM) (Pbody mass (P=0.99) was unchanged. Additionally, reductions were observed in abdominal (Pcancer patients exhibited improved insulin sensitivity and body composition to a similar degree as eugonadal men.

  4. Insulin and the Brain

    Directory of Open Access Journals (Sweden)

    Grosu Cristina

    2017-12-01

    Full Text Available The brain represents an important site for the action of insulin. Besides the traditionally known importance in glucoregulation, insulin has significant neurotrophic properties and influences the brain activity: insulin influences eating behavior, regulates the storage of energy and several aspects concerning memory and knowledge. Insulin resistance and hyperinsulinism could be associated with brain aging, vascular and metabolic pathologies. Elucidating the pathways and metabolism of brain insulin could have a major impact on future targeted therapies.

  5. Pharmacoeconomic analysis of clinical efficiency of combined metformin (Siofor - insulin therapy in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    I Yu Demidova

    2009-06-01

    Full Text Available Aim. To assess expedience of metformin combination with long-acting insulin, determine optimal doses of metformin for patients with type 2 diabetesmellitus (DM2, and accomplish pharmacoeconomic analysis of clinical efficiency of various therapeutic modalities. Materials and methods. Patients with decompensated DM2 (n=126 were under observation for 1 year during which they received rational hypoglycemictherapy with metformin and long-acting insulin (LAI at bedtime, with the dose being titrated until the desired level of glycemic control wasachieved. The patients were randomly allocated to the following 3 groups: group 1 (sulponylurea derivatives (SUD, LAI, and metformin at a doseof 1000 mg b.i.d., group 2 (SUD, LAI, and metformin at 500 mg b.i.d., group 3 (SUD and LAI. In case of postprandial glycemia >9 mmol/l at amaximum dose of SUD, it was replaced by short-acting insulin. Cost-effectiveness analysis of different therapeutic regimes was performed. Results. The cost of examination and treatment of patients given SUD and LAI in combination with metformin at a daily dose of 2000 mg to achievethe desired quality of glycemic control was lower compared with two other groups. Moreover, this therapy was most efficacious and ensured the desiredlevel of glycemic control in a greater number of patients. Cost-effectiveness analysis confirmed advantages of this treatment. Conclusion. Combined hypoglycemic therapy with SUD, LAI, and metformin (200 mg daily has the advantage of lowest cost and maximum efficiencycompared with other modalities.

  6. Avances en terapia insulínica en la diabetes mellitus tipo 1: Aciertos y desaciertos Advances in insulin-therapy in type 1 diabetes mellitus: Success and failures

    Directory of Open Access Journals (Sweden)

    Tania Mayvel Espinosa Reyes

    2007-04-01

    Full Text Available La historia del desarrollo del tratamiento farmacológico de la diabetes tuvo un capítulo esencial en el descubrimiento de la insulina y su introducción como terapia de la diabetes tipo 1. El conocimiento de sus complicaciones trajo consigo la necesidad de una terapia más sofisticada. Desde entonces, las preparaciones de insulina y las estrategias terapéuticas han ido desarrollándose inicialmente a expensas del origen de la insulina, y posteriormente con la incorporación de sustancias que modificaban su absorción. Ya en la década de los 90 surgieron entonces los análogos de la insulina, con una especial capacidad de cambio en su farmacocinética. Más adelante se introdujeron nuevas formas de liberación, que son, las bombas de infusión continua, los aerosoles y todo esto apoyado por nuevos sistemas de monitorización de la glucosa. En la última década el trasplante de islotes y la terapia génica con la obtención de células ß a partir de células madres pluripotenciales, aumentan las expectativas en este campo. Todos estos elementos confirman el interminable camino en la búsqueda de terapéuticas eficaces en el tratamiento de la diabetes mellitus tipo 1. Con este trabajo nos proponemos exponer los principales avances en materia de terapia insulínica y reflexionar sobre aciertos y desaciertos en su introducción.History of development of pharmacological treatment of diabetes had an essential chapter in descovery of insulin and its introduction as therapy of Type 1 diabetes. Knowledge of its complications, lead to the need of a more sophisticated therapy. Since then, insulin preparations and therapeutical strategies has been initially developing at the expense of insulin origin, and then with incorporation of substances modifying its absorption. As long as in 1990, emerged insulin analogues with an special change ability in its pharmacokinetics. Then, new ways of release were introduced, e.g. continuous infusion pumps, aerosols

  7. Exponential increase in postprandial blood-glucose exposure with increasing carbohydrate loads using a linear carbohydrate-to-insulin ratio.

    Science.gov (United States)

    Marran, K J; Davey, B; Lang, A; Segal, D G

    2013-04-10

    Postprandial glucose excursions contribute significantly to average blood glucose, glycaemic variability and cardiovascular risk. Carbohydrate counting is a method of insulin dosing that balances carbohydrate load to insulin dose using a fixed ratio. Many patients and current insulin pumps calculate insulin delivery for meals based on a linear carbohydrate-to-insulin relationship. It is our hypothesis that a non-linear relationship exists between the amounts of carbohydrate consumed and the insulin required to cover it. To document blood glucose exposure in response to increasing carbohydrate loads on fixed carbohydrate-to-insulin ratios. Five type 1 diabetic subjects receiving insulin pump therapy with good control were recruited. Morning basal rates and carbohydrate- to-insulin ratios were optimised. A Medtronic glucose sensor was used for 5 days to collect data for area-under-the-curve (AUC) analysis, during which standardised meals of increasing carbohydrate loads were consumed. Increasing carbohydrate loads using a fixed carbohydrate-to-insulin ratio resulted in increasing glucose AUC. The relationship was found to be exponential rather than linear. Late postprandial hypoglycaemia followed carbohydrate loads of >60 g and this was often followed by rebound hyperglycaemia that lasted >6 hours. A non-linear relationship exists between carbohydrates consumed and the insulin required to cover them. This has implications for control of postprandial blood sugars, especially when consuming large carbohydrate loads. Further studies are required to look at the optimal ratios, duration and type of insulin boluses required to cover increasing carbohydrate loads.

  8. Successful Management of Insulin Allergy and Autoimmune Polyendocrine Syndrome Type 4 with Desensitization Therapy and Glucocorticoid Treatment: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Joselyn Rojas

    2014-01-01

    Full Text Available Introduction. Insulin allergy is a rare complication of insulin therapy, especially in type 1 diabetes mellitus (T1DM. Key manifestations are hypersensitivity-related symptoms and poor metabolic control. T1DM, as well as insulin allergy, may develop in the context of autoimmune polyendocrine syndrome (APS, further complicating management. Case Report. A 17-year-old male patient, diagnosed with T1DM, was treated with various insulin therapy schemes over several months, which resulted in recurrent anaphylactoid reactions and poor glycemic control, after which he was referred to our Endocrinology and Immunology Department. A prick test was carried out for all commercially available insulin presentations and another insulin scheme was designed but proved unsuccessful. A desensitization protocol was started with Glargine alongside administration of Prednisone, which successfully induced tolerance. Observation of skin lesions typical of vitiligo prompted laboratory workup for other autoimmune disorders, which returned positive for autoimmune gastritis/pernicious anemia. These findings are compatible with APS type 4. Discussion. To our knowledge, this is the first documented case of insulin allergy in type 4 APS, as well as this particular combination in APS. Etiopathogenic components shared by insulin allergy and APS beg for further research in immunogenetics to further comprehend pathophysiologic aspects of these diseases.

  9. High Prevalence of Dyslipidemia and Insulin Resistance in HIV-infected Prepubertal African Children on Antiretroviral Therapy.

    Science.gov (United States)

    Innes, Steve; Abdullah, Kameelah L; Haubrich, Richard; Cotton, Mark F; Browne, Sara H

    2016-01-01

    Data describing the true extent of antiretroviral therapy (ART)-induced dyslipidemia and insulin resistance in perinatally infected children on ART in Africa are sparse. Fasting total cholesterol, low-density lipoprotein (LDL), high-density lipoprotein (HDL), triglycerides, insulin and glucose were performed on the first 100 of 190 pediatric ART clinic attendees. Diet assessment was performed by a trained dietician. Lipoatrophy was formally graded by consensus between 2 expert HIV pediatricians. Durations of previous ART exposures, clinical stage, pre-ART viral load, nadir and current CD4 were recorded. Dual-energy X-ray absorptiometry was performed on a subset of 42 patients selected semi-randomly. Prevalences of insulin resistance, abnormal total cholesterol, LDL, HDL and triglyceride were 10%, 13%, 12%, 13% and 9%, respectively. Overall, 40% had at least 1 lipid abnormality or insulin resistance. Adjusted mean LDL cholesterol increased by 0.24 mmol/L for each additional year of cumulative lopinavir/r exposure (P = 0.03) after correcting for age, gender, body mass index, previous stavudine exposure, age at ART initiation, dietary fat and refined carbohydrate, whereas adjusted mean LDL cholesterol was 0.9 mmol/L higher in children exposed to efavirenz within the previous 6 months (P = 0.02). Adjusting for age, gender and ethnicity, dual-energy X-ray absorptiometry revealed that greater trunk fat and lower peripheral subcutaneous fat were associated with elevated triglycerides but not with total cholesterol, LDL, HDL or homeostatic model assessment. Similarly, the presence of visually obvious lipoatrophy was associated with elevated triglycerides but not with total cholesterol, LDL, HDL, homeostatic model assessment or lactate. Prevalences of insulin resistance and dyslipidemia were high. Cumulative lopinavir is an independent risk factor for dyslipidemia, with efavirenz exposure having only transitory effect.

  10. Influence of dietary protein on postprandial blood glucose levels in individuals with Type 1 diabetes mellitus using intensive insulin therapy.

    Science.gov (United States)

    Paterson, M A; Smart, C E M; Lopez, P E; McElduff, P; Attia, J; Morbey, C; King, B R

    2016-05-01

    To determine the effects of protein alone (independent of fat and carbohydrate) on postprandial glycaemia in individuals with Type 1 diabetes mellitus using intensive insulin therapy. Participants with Type 1 diabetes mellitus aged 7-40 years consumed six 150 ml whey isolate protein drinks [0 g (control), 12.5, 25, 50, 75 and 100] and two 150 ml glucose drinks (10 and 20 g) without insulin, in randomized order over 8 days, 4 h after the evening meal. Continuous glucose monitoring was used to assess postprandial glycaemia. Data were collected from 27 participants. Protein loads of 12.5 and 50 g did not result in significant postprandial glycaemic excursions compared with control (water) throughout the 300 min study period (P > 0.05). Protein loads of 75 and 100 g resulted in lower glycaemic excursions than control in the 60-120 min postprandial interval, but higher excursions in the 180-300 min interval. In comparison with 20 g glucose, the large protein loads resulted in significantly delayed and sustained glucose excursions, commencing at 180 min and continuing to 5 h. Seventy-five grams or more of protein alone significantly increases postprandial glycaemia from 3 to 5 h in people with Type 1 diabetes mellitus using intensive insulin therapy. The glycaemic profiles resulting from high protein loads differ significantly from the excursion from glucose in terms of time to peak glucose and duration of the glycaemic excursion. This research supports recommendations for insulin dosing for large amounts of protein. © 2015 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  11. Insulin therapy does not interfere with venous endothelial function evaluation in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Antônio Marcos Vargas da Silva

    2010-01-01

    Full Text Available INTRODUCTION: Endothelium-dependent dilation is improved in insulin-treated diabetic patients, but this effect is probably due to improved glycemic control. The objective of the present study was to compare endothelium-dependent dilation in patients with well-controlled type 2 diabetes who are or are not using insulin as part of their therapy. METHODS: We studied 27 patients with type 2 diabetes (11 women, 60.3 years ± 6 years, with HbA1c < 7% and no nephropathy, including 16 patients treated with anti-diabetic agents (No-Ins, 8 women and 11 patients treated with insulin alone or in combination with anti-diabetic agents (Ins, 3 women. Endothelial function was evaluated by the dorsal hand vein technique, which measures changes in vein diameter in response to phenylephrine, acetylcholine (endothelium-dependent vasodilation and sodium nitroprusside (endothelium-independent vasodilation. RESULTS: Age, systolic blood pressure (No-Ins: 129.4 mmHg ± 11.8 mmHg, Ins: 134.8 mmHg ± 12.0 mmHg; P= 0.257, HbA1c, lipids and urinary albumin excretion rate [No-Ins: 9 mg/24 h (0-14.1 mg/24 h vs. Ins: 10.6 mg/24 h (7.5-14.4 mg/24 h, P=0.398] were similar between groups. There was no difference between endothelium-dependent vasodilation of the No-Ins group (59.3% ± 26.5% vs. the Ins group (54.0% ± 16.3%; P=0.526. Endothelium-independent vasodilation was also similar between the No-Ins (113.7% ± 35.3% and Ins groups (111.9% ± 28.5%; P=0.888. CONCLUSIONS: Subcutaneous insulin therapy does not interfere with venous endothelial function in type 2 diabetes when glycemic and blood pressure control are stable.

  12. Insulin therapy does not interfere with venous endothelial function evaluation in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Silva, Antônio Marcos Vargas da; Penno, Luciana de Moraes; Bertoluci, Marcello Casaccia; Irigoyen, Maria Cláudia; Schaan, Beatriz D'Agord

    2010-01-01

    Endothelium-dependent dilation is improved in insulin-treated diabetic patients, but this effect is probably due to improved glycemic control. The objective of the present study was to compare endothelium-dependent dilation in patients with well-controlled type 2 diabetes who are or are not using insulin as part of their therapy. We studied 27 patients with type 2 diabetes (11 women, 60.3 years ± 6 years, with HbA1c < 7% and no nephropathy), including 16 patients treated with anti-diabetic agents (No-Ins, 8 women) and 11 patients treated with insulin alone or in combination with anti-diabetic agents (Ins, 3 women). Endothelial function was evaluated by the dorsal hand vein technique, which measures changes in vein diameter in response to phenylephrine, acetylcholine (endothelium-dependent vasodilation) and sodium nitroprusside (endothelium-independent vasodilation). Age, systolic blood pressure (No-Ins: 129.4 mmHg ± 11.8 mmHg, Ins: 134.8 mmHg ± 12.0 mmHg; P= 0.257), HbA1c, lipids and urinary albumin excretion rate [No-Ins: 9 mg/24 h (0-14.1 mg/24 h) vs. Ins: 10.6 mg/24 h (7.5-14.4 mg/24 h), P=0.398] were similar between groups. There was no difference between endothelium-dependent vasodilation of the No-Ins group (59.3% ± 26.5%) vs. the Ins group (54.0% ± 16.3%; P=0.526). Endothelium-independent vasodilation was also similar between the No-Ins (113.7% ± 35.3%) and Ins groups (111.9% ± 28.5%; P=0.888). Subcutaneous insulin therapy does not interfere with venous endothelial function in type 2 diabetes when glycemic and blood pressure control are stable.

  13. Insulin biosimilars: the impact on rapid-acting analogue-based therapy.

    Science.gov (United States)

    Franzè, S; Cilurzo, F; Minghetti, P

    2015-04-01

    The impending expiration of patent protection for recombinant insulins provides the opportunity to introduce cost-saving copies, named biosimilars, onto the market. Although there is broad experience in the production and characterisation of insulins, the development of copies is still a challenge. In this paper, the main features of insulins and the EU regulatory framework for their biosimilar products are reviewed. The main focus is on rapid-acting insulin analogues (Humalog(®); Novolog(®)/NovoRapid(®); Apidra(®)). Since they differ by one or two amino acids in chain B, production of one biosimilar for all three drug products is not feasible. However, from post-marketing-collected clinical data, rapid-acting insulin analogues seem to have similar therapeutic efficacy. It is reasonable to suppose that, for prescription to treatment-naïve patients, the cheaper biosimilar would be the preferred choice of physicians, either spontaneously or induced by health insurance. Therefore, its introduction will affect the market share of all the other rapid-acting insulin analogues.

  14. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial

    NARCIS (Netherlands)

    Hermanides, J.; Nørgaard, K.; Bruttomesso, D.; Mathieu, C.; Frid, A.; Dayan, C. M.; Diem, P.; Fermon, C.; Wentholt, I. M. E.; Hoekstra, J. B. L.; DeVries, J. H.

    2011-01-01

    To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with

  15. Antibiotic stability related to temperature variations in elastomeric pumps used for outpatient parenteral antimicrobial therapy (OPAT).

    Science.gov (United States)

    Voumard, Rachel; Van Neyghem, Niklas; Cochet, Camille; Gardiol, Céline; Decosterd, Laurent; Buclin, Thierry; de Valliere, Serge

    2017-05-01

    Elastomeric pumps can be used for the continuous administration of antimicrobials in the outpatient setting. A potentially limiting factor in their use is the stability of antimicrobials. To investigate under real-life conditions the temperature variations of antibiotic solutions contained in elastomeric pumps, and to examine under such conditions the stability of five antibiotics. Healthy volunteers carried the elastomeric pumps in carry pouches during their daily activities. A thermologger measured the temperatures every 15 min over 24 h. Antibiotic concentrations were measured by HPLC coupled to tandem MS. During daytime, the temperature of solutions in the pumps increased steadily, warming to >30°C. During the night, when the pumps were kept attached to the waist, the temperatures reached up to 33°C. The use of white carry pouches avoided excessive temperature increases. Over seven experiments, cefazolin, cefepime, piperacillin and tazobactam were found to be stable over 24 h. Flucloxacillin showed a mean decrease in concentration of 11% ( P  = 0.001). Real-life situations can cause significant temperature rises in elastomeric pumps, thereby potentially increasing the risk of antibiotic degradation. Patients should be instructed to avoid situations causing excessive temperature increases. Despite these temperature variations, cefazolin, cefepime, piperacillin and tazobactam were found to be stable over 24 h. A moderate degradation was noticed for flucloxacillin, albeit most probably not to an extent that might impair anti-infective efficacy. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Professional continuous glucose monitoring for the identification of type 1 diabetes mellitus among subjects with insulin therapy.

    Science.gov (United States)

    Chen, Yin-Chun; Huang, Yu-Yao; Li, Hung-Yuan; Liu, Shih-Wei; Hsieh, Sheng-Hwu; Lin, Chia-Hung

    2015-01-01

    The identification of type 1 diabetes in diabetic subjects receiving insulin therapy is sometimes difficult. The purpose of this study is to evaluate whether results of professional continuous glucose monitoring can improve the identification of type 1 diabetes.From 2007 to 2012, 119 adults receiving at least twice-daily insulin therapy and professional continuous glucose monitoring were recruited. Type 1 diabetes was diagnosed by endocrinologists according to American Diabetes Association standards, including a very low C-peptide level (diabetic ketoacidosis. Continuous glucose monitoring was applied for 3 days.Among 119 subjects, 86 were diagnosed with type 1 diabetes. Subjects with type 1 diabetes were younger (33.8 vs 52.3 years old, P 1), had lower body mass index (BMI, 21.95 vs 24.42, P = 0.003), lower serum creatinine (61.77  vs 84.65 μmol/L, P = 0.001), and higher estimated glomerular filtration rate (108.71 vs 76.48 mg/mL/min/1.73m2, P 1) than subjects with type 2 diabetes. Predictive scores for identification of type 1 diabetes were constructed, including age, BMI, average mean amplitude of glucose excursion in days 2 and 3, and the area under the curve of nocturnal hyperglycemic and hypoglycemic states. The area under the receiver operating characteristic curve was 0.90. With the cutoff of 0.58, the sensitivity was 86.7% and the specificity was 80.8%. The good performance was validated by the leave-one-out method (sensitivity 83.3%, specificity 73.1%).Professional continuous glucose monitoring is a useful tool that improves identification of type 1 diabetes among diabetic patients receiving insulin therapy.

  17. Endothelial function and insulin resistance in polycystic ovary syndrome: the effects of medical therapy.

    Science.gov (United States)

    Teede, Helena J; Meyer, Caroline; Hutchison, Samantha K; Zoungas, Sophia; McGrath, Barry P; Moran, Lisa J

    2010-01-01

    To assess the interaction between insulin resistance and endothelial function and the optimal treatment strategy addressing cardiovascular risk in polycystic ovary syndrome. Randomized controlled trial. Controlled clinical study. Overweight age- and body mass index-matched women with polycystic ovary syndrome. Six months metformin (1 g two times per day, n = 36) or oral contraceptive pill (OCP) (35 microg ethinyl E(2)-2 mg cytoproterone acetate, n = 30). Fasting and oral glucose tolerance test glucose and insulin levels, endothelial function (flow-mediated dilation, asymmetric dimethylarginine, plasminogen activator inhibitor-1, von Willebrand factor), inflammatory markers (high-sensitivity C-reactive protein), lipids, and hyperandrogenism. The OCP increased levels of glucose and insulin on oral glucose tolerance test, high-sensitivity C-reactive protein, triglycerides, and sex-hormone binding globulin and decreased levels of low-density lipoprotein cholesterol and T. Metformin decreased levels of fasting insulin, oral glucose tolerance test insulin, high-density lipoprotein cholesterol, and high-sensitivity C-reactive protein. Flow-mediated dilation increased only with metformin (+2.2% +/- 4.8%), whereas asymmetric dimethylarginine decreased equivalently for OCP and metformin (-0.3 +/- 0.1 vs. -0.1 +/- 0.1 mmol/L). Greater decreases in plasminogen activator inhibitor-1 occurred for the OCP than for metformin (-1.8 +/- 1.6 vs. -0.7 +/- 1.7 U/mL). In polycystic ovary syndrome, metformin improves insulin resistance, inflammatory markers, and endothelial function. The OCP worsens insulin resistance and glucose homeostasis, inflammatory markers, and triglycerides and has neutral or positive endothelial effects. The effect of the OCP on cardiovascular risk in polycystic ovary syndrome is unclear. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Concentrated insulins: the new basal insulins

    Directory of Open Access Journals (Sweden)

    Lamos EM

    2016-03-01

    Full Text Available Elizabeth M Lamos,1 Lisa M Younk,2 Stephen N Davis3 1Division of Endocrinology, Diabetes and Nutrition, 2Department of Medicine, University of Maryland School of Medicine, 3Department of Medicine, University of Maryland Medical Center, Baltimore, MD, USA Introduction: Insulin therapy plays a critical role in the treatment of type 1 and type 2 diabetes mellitus. However, there is still a need to find basal insulins with 24-hour coverage and reduced risk of hypoglycemia. Additionally, with increasing obesity and insulin resistance, the ability to provide clinically necessary high doses of insulin at low volume is also needed. Areas covered: This review highlights the published reports of the pharmacokinetic (PK and glucodynamic properties of concentrated insulins: Humulin-R U500, insulin degludec U200, and insulin glargine U300, describes the clinical efficacy, risk of hypoglycemic, and metabolic changes observed, and finally, discusses observations about the complexity of introducing a new generation of concentrated insulins to the therapeutic market. Conclusion: Humulin-R U500 has a similar onset but longer duration of action compared with U100 regular insulin. Insulin glargine U300 has differential PK/pharmacodynamic effects when compared with insulin glargine U100. In noninferiority studies, glycemic control with degludec U200 and glargine U300 is similar to insulin glargine U100 and nocturnal hypoglycemia is reduced. Concentrated formulations appear to behave as separate molecular entities when compared with earlier U100 insulin analog compounds. In the review of available published data, newer concentrated basal insulins may offer an advantage in terms of reduced intraindividual variability as well as reducing the injection burden in individuals requiring high-dose and large volume insulin therapy. Understanding the PK and pharmacodynamic properties of this new generation of insulins is critical to safe dosing, dispensing, and administration

  19. Clinical and economic benefits of integrated pump/CGM technology therapy in patients with type 1 diabetes in Colombia.

    Science.gov (United States)

    Gomez, Ana Maria; Alfonso-Cristancho, Rafael; Orozco, John Jairo; Lynch, Peter Matthew; Prieto, Diana; Saunders, Rhodri; Roze, Stephane; Valencia, Juan Esteban

    2016-11-01

    To assess the long-term clinical and economic impact of integrated pump/CGM technology therapy as compared to multiple daily injections (MDI), for the treatment of type 1 diabetes (T1D) in Colombia. The CORE Diabetes Model was used to simulate a hypothetical cohort of patients with T1D. Mean baseline characteristics were taken from a clinical study conducted in Colombia and a healthcare payer perspective was adopted, with a 5% annual discount rate applied to both costs and outcomes. The integrated pump/CGM improved mean life expectancy by 3.51 years compared with MDI. A similar increase occurred in mean quality-adjusted life expectancy with an additional 3.81 quality-adjusted life years (QALYs). Onset of diabetes-related complications was also delayed as compared to MDI, and mean survival time free of complication increased by 1.74 years with integrated pump/CGM. Although this increased treatment costs of diabetes as compared to MDI, savings were achieved thanks to reduced expenditure on diabetes-related complications. The estimated incremental cost-effectiveness ratio (ICER) for SAP was Colombian Pesos (COP) 44,893,950 (approximately USD$23,200) per QALY gained. Improved blood glucose control associated to integrated pump/CGM results in a decreased incidence of diabetes-related complications and improves life expectancy as compared to MDI. Using recommended thresholds from the World Health Organization and previous coverage decisions about health technologies in Colombia, it is a cost-effective alternative to MDI for the treatment of type 1 diabetes in Colombia. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  1. Short-term intensive insulin therapy could be the preferred option for new onset Type 2 diabetes mellitus patients with HbA1c > 9.

    Science.gov (United States)

    Weng, Jianping

    2017-10-01

    Type 2 diabetes mellitus (T2DM) is a heterogeneous disease. Currently, the typical clinical therapeutic pathway for the disease consists of the stepwise addition of antihyperglycemic preparations over time, followed lastly by insulin therapy when functional β-cell capacity is severely deteriorated. Recognizing the complexity of disease management, personalized (precision) medicine approaches may enable the physician to tailor diabetes treatment based on HbA1c levels, body mass index (BMI), efficacy, risk of hypoglycemia, risk of weight gain, age, safety, cost, and even genetic characteristics. Although insulin therapy has traditionally been recommended as the last option in the sequential treatment algorithm of T2DM, it is notable that several guidelines and consensus statements suggest consideration of insulin as part of a first-line regimen. In the American Association of Clinical Endocrinologists (AACE)/American College of Endocrinology (ACE) comprehensive T2DM 2017 management algorithm, insulin is recommended for T2DM patients presenting with symptoms and an HbA1c >9.0%. In addition, the American Diabetes Association (ADA)/European Association for the Study of Diabetes (EASD) consensus statement recommends initial insulin therapy as an option when HbA1c ≥9%, and definite consideration with HbA1c ≥10-12%, and mentions that it may be possible to taper off insulin once initial glucotoxicity is reversed and to consider transfer to other types of non-insulin therapies. Based on accumulating evidence, an expert group has endorsed the concept of short-term intensive insulin (STII) therapy as an option for some patients with T2DM at the time of diagnosis. Notably, the latest Israeli guidelines suggest considering immediate, sometimes short-term, insulin treatment for patients with HbA1c >9% or with symptoms. It has been reported that nearly one-quarter (23%) of newly diagnosed T2DM patients in the US had an HbA1c ≥9.0% prior to initiation of treatment. For such

  2. Influence of orlistat therapy on serum insulin level and morphological and functional parameters of peripheral arterial circulation in obese patients

    Directory of Open Access Journals (Sweden)

    Hajduković Zoran

    2005-01-01

    Full Text Available Background/Aim. Insulin resistance is related to accelerated atherosclerosis, whereas weight loss is associated with the increasing insulin sensitivity, the improvement of functional and the morphological parameters of arterial circulation, and the reduction of cardiovascular morbidity and mortality. The aim of our study was to evaluate the influence of orlistat treatment on serum insulin level and functional and morphologic parameters of peripheral arterial circulation. Methods. We conducted a prospective, randomized, double − blind, placebo − controlled study. Thirty patients with body mass index over 30 kg/m2 normotensive, nonsmokers, without clinically manifested cardiovascular disease or diabetes were randomly assigned either orlistat (120 mg, 3 times daily; n = 20 or placebo (n = 10 in a double − blind manner. All of the patients were on individually calculated hypocaloric diet. The follow-up period was 24 weeks. Arterial pressure, fasting serum glucose and insulin level, triglycerides, total cholesterol and low density lipoprotein-cholesterol were determined at the beginning, following 3 and 6 months. Also, the intima − media thickness of right superficial femoral artery and the mean blood flow velocity were determined with ultrasonography. Results. Inside the period of 3 and 6 months, there were the greater reductions of body mass index, arterial pressure, fasting glucose and insulin level, total cholesterol, low density lipoproteins, as well as the greater reductions of mean velocity blood flow and peripheral pulse pressure in the orlistat group vs the placebo group (p < 0.01. Greater reductions in the waist circumference and intima − media thickness were registered following 6 months in the orlistat vs the placebo group (p < 0.01. Conclusion. In the group of obese patients orlistat therapy reduced risk factors, serum insulin level and improved early arterial functional changes as assessed with the reductions of the mean

  3. Symptoms of depression and diabetes-specific emotional distress are associated with a negative appraisal of insulin therapy in insulin-naive patients with Type 2 diabetes mellitus. A study from the European Depression in Diabetes [EDID] Research Consortium

    NARCIS (Netherlands)

    Makine, C.; Karsidag, C.; Kadioglu, P.; Ilkova, H.; Karsidag, K.; Skovlund, S.E.; Snoek, F.J.; Pouwer, F.

    2009-01-01

    Aims: A meta-analysis concluded that depression is associated with poor glycaemic control in Type 2 diabetes (DM2). In DM2 patients with deteriorating glycaemic control, the initiation of insulin therapy is often postponed. The aim of the present study was to determine whether symptoms of depression

  4. Insulin-like growth factor family and combined antisense approach in therapy of lung carcinoma.

    OpenAIRE

    Pavelić, Jasminka; Pavelić, Ljubomir; Karadza, Jerolim; Krizanac, Simun; Unesić, Josip; Spaventi, Sime; Pavelić, Kresimir

    2002-01-01

    BACKGROUND: Perturbation in a level of any peptide from insulin-like growth factor (IGF) family (ligands, receptors, and binding proteins) seems to be implicated in lung cancer formation; IGF ligands and IGF-I receptor through their mitogenic and anti-apoptotic action, and the mannose 6-phosphate/insulin-like growth factor II receptor (M6-P/IGF-IIR) possibly as a tumor suppressor. MATERIALS AND METHODS: To determine the identity, role, and mutual relationship of IGFs in lung cancer growth and...

  5. INSULIN AND INSULIN RESISTANCE: NEW MOLECULE MARKERS AND TARGET MOLECULE FOR THE DIAGNOSIS AND THERAPY OF DISEASES OF THE CENTRAL NERVOUS SYSTEM

    Directory of Open Access Journals (Sweden)

    A. B. Salmina

    2013-01-01

    Full Text Available The review summarizes current data on the role of insulin in the regulation of t glucose metabolism in the central nervous system at physiologic and pathologic conditions. For many years, the brain has been considered as an insulin-independent organ which utilizes glucose without insulin activity. However, it is become clear now that insulin not only regulates glucose transport and metabolism, but also has modulatory efftects in impact on excitability, proliferation and differentiation of brain progenitor cells, synaptic plasticity and memory formation, secretion of neurotransmitters, apoptosis. We have critically reviewed literature information and our own data on the role of insulin and insulin resistance in neuron-glia metabolic coupling, regulation of NAD+ metabolism and action of NAdependent enzymes, neurogenesis, brain development in (pathophysiological conditions. The paper clarifies interrelations between alterations in glucose homeostasis, development of insulin resistance and development of neurodegeneration (Alzheimer's disease and Parkinson's disease, autism, stroke, and depression. We discuss the application of novel molecular markers of insulin resistance (adipokines, α-hydroxybutyrate, BDNF, insulin-regulated aminopeptidase, provasopressin and molecular targets for diagnostics and treatment of brain disorders associated with insulin resistance.

  6. Position Statement on the management of continuous subcutaneous insulin infusion (CSII): The Italian Lazio experience.

    Science.gov (United States)

    Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella

    2016-01-01

    This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  7. Effect of intensive insulin therapy on macular biometrics, plasma VEGF and its soluble receptor in newly diagnosed diabetic patients.

    Science.gov (United States)

    Hernández, Cristina; Zapata, Miguel A; Losada, Eladio; Villarroel, Marta; García-Ramírez, Marta; García-Arumí, José; Simó, Rafael

    2010-07-01

    To evaluate whether intensive insulin therapy leads to changes in macular biometrics (volume and thickness) in newly diagnosed diabetic patients with acute hyperglycaemia and its relationship with serum levels of vascular endothelial growth factor (VEGF) and its soluble receptor (sFlt-1). Twenty-six newly diagnosed diabetic patients admitted to our hospital to initiate intensive insulin treatment were prospectively recruited. Examinations were performed on admission (day 1) and during follow-up (days 3, 10 and 21) and included a questionnaire regarding the presence of blurred vision, standardized refraction measurements and optical coherence tomography. Plasma VEGF and sFlt-1 were assessed by ELISA at baseline and during follow-up. At study entry seven patients (26.9%) complained of blurred vision and five (19.2%) developed burred vision during follow-up. Macular volume and thickness increased significantly (p = 0.008 and p = 0.04, respectively) in the group with blurred vision at day 3 and returned to the baseline value at 10 days. This pattern was present in 18 out of the 24 eyes from patients with blurred vision. By contrast, macular biometrics remained unchanged in the group without blurred vision. We did not detect any significant changes in VEGF levels during follow-up. By contrast, a significant reduction of sFlt-1 was observed in those patients with blurred vision at day 3 (p = 0.03) with normalization by day 10. Diabetic patients with blurred vision after starting insulin therapy present a significant transient increase in macular biometrics which is associated with a decrease in circulating sFlt-1. Copyright (c) 2010 John Wiley & Sons, Ltd.

  8. Diamel Therapy in Polycystic Ovary Syndrome Reduces Hyperinsulinaemia, Insulin Resistance, and Hyperandrogenaemia

    Directory of Open Access Journals (Sweden)

    Arturo Hernández-Yero

    2012-01-01

    Full Text Available For to determine the effect of Diamel on the insulin resistance, insulin sensitivity, and sexual hormones results in women with polycystic ovary syndrome (PCOS. A study was carried out on 37 patients with this disorder. A triple-blind clinical trial was designed in which the Diamel food supplement was compared with a placebo. The women with reproductive ages were randomly distributed in two groups, with 18 and 19 women respectively, and they took Diamel or placebo and were followed up during 6 months with clinical and biochemical evaluation. A significant decrease in the HOMA-IR from the initial value at six months was observed in the group with Diamel. The insulin sensitivity improved considerably in this group. The rate of menstrual recovery was higher in the group with Diamel, and two patients from this group obtained pregnancy. The hormone levels shows a significant decrease in testosterone at 3 months in the group with Diamel compared with the control group. The LH also decreases in the same group when comparing the start with 6 months.We concluded that the Diamel decreases insulin resistance and improves sensitivity to this hormone in women with PCOS, with improvement in the levels of LH and testosterone.

  9. Insulin resistance, role of metformin and other noninsulin therapies in pediatric type 1 diabetes

    Science.gov (United States)

    Type 1 diabetes mellitus (T1DM) in youth is a challenging chronic medical condition. Its management should address not only the glycemic control but also insulin resistance and cardiovascular disease risk factors which are increasingly recognized to be present in youth with TID. Current knowledge on...

  10. Refining basal insulin therapy: what have we learned in the age of analogues?

    NARCIS (Netherlands)

    DeVries, J. H.; Nattrass, M.; Pieber, T. R.

    2007-01-01

    BACKGROUND: The basal insulin analogues glargine and detemir have been subject to a series of trials comparing their clinical profiles to the conventional preparation, neutral protamine Hagedorn (NPH). Careful review of these trials provides opportunities to learn clinically useful lessons about

  11. Switching to multiple daily injection therapy with glulisine improves glycaemic control, vascular damage and treatment satisfaction in basal insulin glargine-injected diabetic patients.

    Science.gov (United States)

    Yanagisawa, Katsuyuki; Ashihara, Junya; Obara, Shinji; Wada, Norio; Takeuchi, Masayoshi; Nishino, Yuri; Maeda, Sayaka; Ishibashi, Yuji; Yamagishi, Sho-ichi

    2014-11-01

    Basal and bolus insulin therapy is required for strict blood control in diabetic patients, which could lead to prevention of vascular complications in diabetes. However, the optimal combination regimen is not well established. Fifty-nine diabetic patients (49 type 1 and 10 type 2; 52.9 ± 13.3 years old) whose blood glucose levels were uncontrolled (HbA1c  > 6.2%) by combination treatment of basal insulin glargine with multiple daily pre-meal injections of bolus short-acting insulin [aspart (n = 19), lispro (n = 37) and regular human insulin (n = 3)] for at least 8 weeks were enrolled in this study. We examined whether glycaemic control and vascular injury were improved by replacement of short-acting insulin with glulisine. Patient satisfaction was assessed with Diabetes Treatment Satisfaction Questionnaire. Although bolus and basal insulin doses were almost unchanged before and after replacement therapy, switching to glulisine insulin for 24 weeks significantly decreased level of HbA1c , advanced glycation end products (AGEs), soluble receptor for AGEs (sRAGE), monocyte chemoattractant protein-1 (MCP-1) and urinary albumin excretion. In multiple stepwise regression analysis, change in MCP-1 values from baseline (ΔMCP-1) was a sole determinant of log urinary albumin excretion. ΔAGEs and ΔsRAGE were independently correlated with each other. The relationship between ΔMCP-1 and ΔsRAGE was marginally significant (p = 0.05). Replacement of short-acting insulin by glulisine significantly increased Diabetes Treatment Satisfaction Questionnaire scores. Our present study suggests that combination therapy of glargine with multiple daily pre-meal injections of glulisine might show superior efficacy in controlling blood glucose, preventing vascular damage and improving treatment satisfaction in diabetic patients. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Protein and fat meal content increase insulin requirement in children with type 1 diabetes – Role of duration of diabetes

    Directory of Open Access Journals (Sweden)

    M. van der Hoogt

    2017-12-01

    Full Text Available Background and objective: Hyperglycaemia remains a challenge in type 1 diabetes since current regimes used to determine meal insulin requirements prove to be ineffective. This is particularly problematic for meals containing high amounts of protein and fat. We aimed to determine the post-prandial glycaemic response and total insulin need for mixed meals, using sensor-augmented insulin pumps in children with type 1 diabetes. Methods: Twenty-two children with type 1 diabetes, aged 4–17 years on insulin pump therapy completed this home-based, cross-over, randomised controlled trial. Two meals with identical carbohydrate content – one with low fat and protein (LFLP and one with high fat and protein (HFHP contents – were consumed using normal insulin boluses. Blood glucose monitoring was done for 10 h post-meal, with correction bolus insulin given two-hourly if required. Results: The HFHP meal required significantly more total insulin (3.48 vs. 2.7 units as a result of increased post-meal correction insulin requirement (1.2 vs. 0.15 units spread over a longer duration (6 vs. 3 h. The HFHP meals significantly increased the time spent above target glucose level. Duration of diabetes and total daily insulin use significantly influenced the post-prandial blood glucose response to the two meals. Conclusion: When consuming carbohydrate-based mixed meals, children with type 1 diabetes on insulin pump therapy, required significantly more insulin over a longer period of time than the insulin requirement calculated using current regimes. This additional amount required is influenced by the duration of diabetes and total daily insulin use. Keywords: Carbohydrate, Protein and fat, Type 1 diabetes, Glucose, Insulin infusion systems

  13. Long-term proton pump inhibitor therapy and falls and fractures in elderly women: a prospective cohort study.

    Science.gov (United States)

    Lewis, Joshua R; Barre, Deka; Zhu, Kun; Ivey, Kerry L; Lim, Ee Mun; Hughes, Jeff; Prince, Richard L

    2014-11-01

    Proton pump inhibitors (PPIs) are widely used in the elderly. Recent studies have suggested that long-term PPI therapy is associated with fractures in the elderly, however the mechanism remains unknown. We investigated the association between long-term PPI therapy ≥1 year and fracture risk factors including bone structure, falls, and balance-related function in a post hoc analysis of a longitudinal population-based prospective cohort of elderly postmenopausal women and replicated the findings in a second prospective study of falling in elderly postmenopausal women. Long-term PPI therapy was associated with increased risk of falls and fracture-related hospitalizations; adjusted odds ratio (AOR) 2.17; 95% CI, 1.25-3.77; p = 0.006 and 1.95; 95% CI, 1.20-3.16; p = 0.007, respectively. In the replication study, long-term PPI use was associated with an increased risk of self-reported falling; AOR, 1.51; 95% CI, 1.00-2.27; p = 0.049. No association of long-term PPI therapy with bone structure was observed; however, questionnaire-assessed falls-associated metrics such as limiting outdoor activity (p = 0.002) and indoor activity (p = 0.001) due to fear of falling, dizziness (p risk in subjects on long-term PPI therapy. This increase in fracture risk in elderly women, already at high risk of fracture, appears to be mediated via increased falls risk and falling rather than impaired bone structure and should be carefully considered when prescribing long-term PPI therapy. © 2014 American Society for Bone and Mineral Research.

  14. Using ultra-rapid insulin analogs in children and adolescents with type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    О.V. Bolshova

    2017-11-01

    Full Text Available Background. The purpose of the study was a retrospective comparative analysis of using insulin analogues of the prolonged and ultra-short action and human genetically engineered insulins of middle and short action in children and adolescents with type 1 diabetes mellitus (DM. Materials and methods. The influence of ultra-rapid insulin analog in comparison with human rapid-action insulin on the course of type 1 DM in 100 children and adolescents was studied. It was applied as basal-bolus regimen of insulin therapy. Analysis of parameters which reflect criteria of insulin therapy effectiveness, positive effect of ultra-rapid insulin analog on the course of DM has been performed. Results. Application of ultra-rapid insulin analog before each meal improved parameters of pre- and postprandial glycemia, decreased the range of fluctuations of blood sugar during the day, reduced and maintained HbA1c level without augmentation of frequency and intensity of hypoglycaemia, and also decreased the level of noctural hypoglycaemia. Conclusions. The ultra-rapid insulin analog is the drug of choice for the effective use in insulin pumps.

  15. Insulin resistance in multiple tissues in patients with type 1 diabetes mellitus on long-term continuous subcutaneous insulin infusion therapy

    NARCIS (Netherlands)

    Donga, Esther; van Dijk, Marieke [Leiden Univ., LUMC; Hoogma, Roel P. L. M.; Corssmit, Eleonora P. M.; Romijn, Johannes A.

    2013-01-01

    The aim of this study was to determine whether insulin resistance is present in lean patients with uncomplicated type 1 diabetes mellitus on long-term continuous subcutaneous insulin infusion (CSII), compared with matched healthy controls. We studied eight patients (four men and four women) with

  16. Adipose tissue NAD+ biology in obesity and insulin resistance: From mechanism to therapy.

    Science.gov (United States)

    Yamaguchi, Shintaro; Yoshino, Jun

    2017-05-01

    Nicotinamide adenine dinucleotide (NAD + ) biosynthetic pathway, mediated by nicotinamide phosphoribosyltransferase (NAMPT), a key NAD + biosynthetic enzyme, plays a pivotal role in controlling many biological processes, such as metabolism, circadian rhythm, inflammation, and aging. Over the past decade, NAMPT-mediated NAD + biosynthesis, together with its key downstream mediator, namely the NAD + -dependent protein deacetylase SIRT1, has been demonstrated to regulate glucose and lipid metabolism in a tissue-dependent manner. These discoveries have provided novel mechanistic and therapeutic insights into obesity and its metabolic complications, such as insulin resistance, an important risk factor for developing type 2 diabetes and cardiovascular disease. This review will focus on the importance of adipose tissue NAMPT-mediated NAD + biosynthesis and SIRT1 in the pathophysiology of obesity and insulin resistance. We will also critically explore translational and clinical aspects of adipose tissue NAD + biology. © 2017 WILEY Periodicals, Inc.

  17. Electroacupuncture and Rosiglitazone Combined Therapy as a Means of Treating Insulin Resistance and Type 2 Diabetes Mellitus: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Rong-Tsung Lin

    2013-01-01

    Full Text Available Aims. To evaluate the efficacy of rosiglitazone (TZD and electroacupuncture (EA combined therapy as a treatment for type 2 diabetes mellitus (T2DM patients by randomized single-blind placebo controlled clinical trial. Methods. A total of 31 newly diagnostic T2DM patients, who fulfilled the study's eligibility criteria, were recruited. The individuals were randomly assigned into two groups, the control group (TZD, N=15 and the experimental group (TZD + EA, N=16. Changes in their plasma free fatty acid (FFA, glucose, and insulin levels, together with their homeostasis model assessment (HOMA indices, were statistically compared before and after treatment. Hypoglycemic activity (% was also compared between these two groups. Results. There was no significant difference in hypoglycemic activity between the TZD and TZD + EA group. The effectiveness of the combined therapy seems to derive from an improvement in insulin resistance and a significant lowering of the secreted insulin rather than the effect of TZD alone on T2DM. The combined treatment had no significant adverse effects. A lower plasma FFA concentration is likely to be the mechanism that causes this effect. Conclusion. This combined therapy seems to suppress endogenous insulin secretion by improving insulin resistance via a mechanism involving a reduction in plasma FFA. This trial is registered with ClinicalTrials.gov NCT01577095.

  18. How and why do patients with Type 1 diabetes sustain their use of flexible intensive insulin therapy? A qualitative longitudinal investigation of patients' self-management practices following attendance at a Dose Adjustment for Normal Eating (DAFNE) course.

    Science.gov (United States)

    Rankin, D; Cooke, D D; Clark, M; Heller, S; Elliott, J; Lawton, J

    2011-05-01

    Conventional insulin therapy requires patients with Type 1 diabetes to adhere to rigid dietary and insulin injection practices. Recent trends towards flexible intensive insulin therapy enable patients to match insulin to dietary intake and lifestyle; however, little work has examined patients' experiences of incorporating these practices into real-life contexts. This qualitative longitudinal study explored patients' experiences of using flexible intensive insulin therapy to help inform the development of effective long-term support. Semi-structured interviews were conducted with 30 adult patients with Type 1 diabetes following participation in a structured education programme on using flexible intensive insulin therapy, and 6 and 12 months post-course. Longitudinal data analysis used an inductive, thematic approach. Patients consistently reported feeling committed to and wanting to sustain flexible intensive insulin therapy. This regimen was seen as a logical and effective method of self-management, as patients experienced improved blood glucose readings and/or reported feeling better. Implementing and sustaining flexible intensive insulin therapy was enhanced when patients had stable routines, with more challenges reported by those working irregular hours and during weekends/holidays. Some patients re-crafted their lives to make this approach work for them; for instance, by creating dietary routines or adjusting dietary choices. Clinical data have shown that flexible intensive insulin therapy can lead to improvement in glycaemic control. This study, drawing on patients' perspectives, provides further endorsement for flexible intensive insulin therapy by demonstrating patients' liking of, and their motivation to sustain, this approach over time. To help patients implement and sustain flexible intensive insulin therapy, follow-up support should encourage them to identify routines to better integrate this regimen into their lives. © 2011 The Authors. Diabetic

  19. Promising therapy of XDR-TB/MDR-TB with thioridazine an inhibitor of bacterial efflux pumps

    DEFF Research Database (Denmark)

    Amaral, L; Martins, M; Viveiros, M

    2008-01-01

    -TB) - a M. tuberculosis organism that is resistant to the most effective second line drugs available for the treatment of TB. This review provides detailed, significant evidence that supports the use of an old neuroleptic compound, thioridazine (TZ), for the management of MDR-TB and XDR-TB infections...... therapy predictably ineffective and death is inevitable, compassionate therapy with TZ should be contemplated. The risks are small and the rewards great....

  20. The impact of extended release exenatide as adjuvant therapy on hemoglobin A1C, weight, and total daily dose of insulin in patients with type 2 diabetes mellitus using U-500 insulin.

    Science.gov (United States)

    Farwig, Phillip A; Zielinski, Angela J; Accursi, Mallory L; Burant, Christopher J

    2017-12-01

    To evaluate the efficacy and safety of adjuvant exenatide extended release (ER) therapy in patients treated with regular U-500 insulin. In this retrospective chart review at an ambulatory care center in the Midwest, 18 patients with type 2 diabetes being treated with regular U-500 insulin and adjuvant exenatide ER were identified. These patients were evaluated for outcomes following the addition of exenatide ER. The primary outcome was change in HbA 1C from baseline to 3, 6, and 12months. Secondary outcomes included change in weight, total daily dose (TDD) of insulin, and hypoglycemia. Repeated measures ANOVA was performed to assess the differences in mean scores over four time periods. A total of 18 of 50 patients met inclusion criteria with sufficient data to be included in analysis. HbA 1C showed non-significant findings from baseline to 12months (8.08% vs. 8.23%; p=0.75). A non-significant, modest weight loss occurred (146.4kgvs. 144.2kg; -2.2kg; p=0.31). A significant decrease in TDD of insulin was observed (378 units vs. 326 units; p1). There was a trend towards hypoglycemia from baseline to month 3 post addition of exenatide ER (0.33 events vs. 1.33 events; p=0.055). In patients treated with regular U-500 insulin, adjuvant exenatide ER therapy showed no significant improvement in HbA 1C , but did show modest weight loss as well as decreased insulin requirements to achieve a HbA 1C that was comparable to baseline. Published by Elsevier B.V.

  1. Health Economic Evaluation of Home and Hospital-Based Care in T2D Patients on Insulin Therapy.

    Science.gov (United States)

    Janati, Ali; Sarabchian, Mohamad Ali; Mohaghegh, Bahram; Aghmohamadzadeh, Naser; Seyedin, Hesam; Gholizadeh, Masumeh; Hasanpoor, Edris

    2017-11-01

    Type 2 Diabetes is a main concern of public health in contemporary world with remarkable mortality, delayed complications and health costs. Governments are obliged to improve the quality of health care and consider appropriate strategies to reduce the costs. An alternative strategy for hospital services is care at home. Therefore, this study was aimed to evaluate the cost-effectiveness of home-based and hospital-based diabetes care. A quasi-experimental, pre-test and post-test design was conducted in Northwest Iran. Sixty subjects who were eligible insulin-treatment type 2 diabetes mellitus were randomly assigned into two equal groups to receive home-based or conventional hospital-based care. Data on glycosylated hemoglobin (HbA1c), hypoglycemia episodes, time needed to achieve glycemic control level, diabetes treatment satisfaction, diabetes knowledge and costs during three months were collected. The cost of home-based care in insulin therapy diabetes was 61% less compared with the hospital-based methods. The former strategy was cost-effective in terms of reduction in HbA1C and the time needed to achieve glycemic control. The patients in home care group were more satisfied and knowledgeable. The care at home approach for type 2 diabetic patients can be introduced and supported as a cost-effective care method in the country.

  2. Microwave pumped high-efficient thermoacoustic tumor therapy with single wall carbon nanotubes.

    Science.gov (United States)

    Wen, Liewei; Ding, Wenzheng; Yang, Sihua; Xing, Da

    2016-01-01

    The ultra-short pulse microwave could excite to the strong thermoacoustic (TA) shock wave and deeply penetrate in the biological tissues. Based on this, we developed a novel deep-seated tumor therapy modality with mitochondria-targeting single wall carbon nanotubes (SWNTs) as microwave absorbing agents, which act efficiently to convert ultra-short microwave energy into TA shock wave and selectively destroy the targeted mitochondria, thereby inducing apoptosis in cancer cells. After the treatment of SWNTs (40 μg/mL) and ultra-short microwave (40 Hz, 1 min), 77.5% of cancer cells were killed and the vast majority were caused by apoptosis that initiates from mitochondrial damage. The orthotopic liver cancer mice were established as deep-seated tumor model to investigate the anti-tumor effect of mitochondria-targeting TA therapy. The results suggested that TA therapy could effectively inhibit the tumor growth without any observable side effects, while it was difficult to achieve with photothermal or photoacoustic therapy. These discoveries implied the potential application of TA therapy in deep-seated tumor models and should be further tested for development into a promising therapeutic modality for cancer treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Reported Benefits of Insulin Therapy for Better Glycemic Control in Type 2 Diabetic Patients–-Is this Applicable in Saudi Patients?

    Directory of Open Access Journals (Sweden)

    Wafaa AlSaggaf

    2016-01-01

    Full Text Available Aim To compare the effect of different treatment regimens (oral hypoglycemic agents [OHGs], insulin therapy, and combination of both on glycemic control and other cardiometabolic risk factors in type 2 diabetes mellitus (T2DM patients in Saudi. Subjects and Methods Patients with T2DM, but no serious diabetic complications, were randomly recruited from the diabetes clinics at two large hospitals in Jeddah, Saudi Arabia, during June 2013 to July 2014. Only those without change in treatment modality for the last 18 months were included. Blood pressure and anthropometric measurements were measured. Treatment plan was recorded from the patients' files. Fasting blood sample was obtained to measure glucose, HbA1c, and lipid profile. Results A total of 197 patients were recruited; 41.1% were men and 58.9% were women. The mean (±SD age was 58.5 ± 10.5 years. Most patients (60.7% were on OHGs, 11.5% on insulin therapy, and 27.7% were using a combination of insulin and OHGs. The mean HbA1c was lower in patients using OHGs only, compared with means in those using insulin, or combined therapy in patients with disease duration of #10 years ( P = 0.001 and also in those with a longer duration of the disease ( P < 0.001. A lower mean diastolic and systolic blood pressure was found among patients on insulin alone ( P < 0.01. No significant differences were found in lipid profiles among the groups. Conclusion Insulin therapy, without adequate diabetes education, fails to control hyperglycemia adequately in Saudi T2DM patients. There is a challenge to find out reasons for poor control and the ways as to how to improve glycemic control in T2DM.

  4. Persistent gastro-oesophageal reflux symptoms despite proton pump inhibitor therapy.

    Science.gov (United States)

    Ang, Daphne; How, Choon How; Ang, Tiing Leong

    2016-10-01

    About one-third of patients with suspected gastro-oesophageal reflux disease (GERD) do not respond symptomatically to proton pump inhibitors (PPIs). Many of these patients do not suffer from GERD, but may have underlying functional heartburn or atypical chest pain. Other causes of failure to respond to PPIs include inadequate acid suppression, non-acid reflux, oesophageal hypersensitivity, oesophageal dysmotility and psychological comorbidities. Functional oesophageal tests can exclude cardiac and structural causes, as well as help to confi rm or exclude GERD. The use of PPIs should only be continued in the presence of acid reflux or oesophageal hypersensitivity for acid reflux-related events that is proven on functional oesophageal tests. Copyright: © Singapore Medical Association.

  5. [Effectiveness and safety of pulsatile GnRH pump therapy on female patients with IHH].

    Science.gov (United States)

    Liu, Zhaoxiang; Mao, Jiangfeng; Wu, Xueyan; Nie, Min; Huang, Bingkun; Xu, Hongli; Wang, Xi; Zheng, Junjie

    2015-11-10

    To investigate the therapeutic effect of pulsatile GnRH (gonadorelin) pump on female patients with idiopathic hypogonadotropic hypogonadism (IHH). In this retrospective study, five female IHH patients were recruited. Patients were treated with pulsatile gonadorelin (10 µg per 90 min) via a pump for at least 12 weeks. Serum gonadotropins and sex steroid levels were measured, and menses were recorded. After one-week treatment, luteinizing hormone (LH) level increased from (2.2 ± 2.0) U/L to (5.4 ± 2.5) U/L (P=0.028), follicle-stimulating hormone(FSH) level increased from (3.7 ± 2.7) U/L to(6.3 ± 1.0) U/L (P=0.162), and estradiol (E2) level increased from (58 ± 13) pmol/L to (260 ± 97) pmol/L (P=0.011). Menstrual bleeding was observed in 4 patients after starting treatment for 35-55 days and two natural pregnancies were reported. No menstrual bleeding was reported in another patient. The frequency of pulsatile GnRH had to be adjusted according to endogenous GnRH secretion during the follicular phase of normal women and regular menses were induced. Pulsatile GnRH is effective in treating female IHH. A constant frequency of pulsatile GnRH is suitable for most of IHH patients. However, for those who failed to produce regular menses, adjusting pulsatile frequency to imitate the physiological rhythm of GnRH may be an alternative option.

  6. Comparison between SGLT2 inhibitors and DPP4 inhibitors added to insulin therapy in type 2 diabetes: a systematic review with indirect comparison meta-analysis.

    Science.gov (United States)

    Min, Se Hee; Yoon, Jeong-Hwa; Hahn, Seokyung; Cho, Young Min

    2017-01-01

    Both sodium glucose cotransporter 2 (SGLT2) inhibitors and dipeptidyl peptidase-4 (DPP4) inhibitors can be used to treat patients with type 2 diabetes mellitus (T2DM) that is inadequately controlled with insulin therapy, and yet there has been no direct comparison of these two inhibitors. We searched MEDLINE, EMBASE, LILACS, the Cochrane Central Register of Controlled Trials and ClinicalTrials.gov through June 2015. Randomized controlled trials published in English that compare SGLT2 inhibitor plus insulin (SGLT2i/INS) with placebo plus insulin or DPP4 inhibitor plus insulin (DPP4i/INS) with placebo plus insulin in patients with T2DM were selected. Data on the study characteristics, efficacy and safety outcomes were extracted. We compared the efficacy and safety between SGLT2i/INS and DPP4i/INS indirectly with covariates adjustment. Risk of potential bias was assessed. Fourteen eligible randomized controlled trials comprising 6980 patients were included (five SGLT2 inhibitor studies and nine DPP4 inhibitor studies). Covariate-adjusted indirect comparison using meta-regression analyses revealed that SGLT2i/INS achieved greater reduction in HbA 1c [weighted mean difference (WMD) -0.24%, 95% confidence interval (CI) -0.43 to -0.05%], fasting plasma glucose (WMD -18.0 mg/dL, 95% CI -28.5 to -7.6 mg/dL) and body weight (WMD -2.38 kg, 95% CI -3.18 to -1.58 kg) from baseline than DPP4i/INS without increasing the risk of hypoglycaemia (relative risks 1.19, 95% CI 0.78 to 1.82). Sodium glucose cotransporter 2 inhibitors achieved better glycaemic control and greater weight reduction than DPP4 inhibitors without increasing the risk of hypoglycaemia in patients with T2DM that is inadequately controlled with insulin. There has been no direct comparison of SGLT2 inhibitors and DPP4 inhibitors in patients with T2DM inadequately controlled with insulin therapy. In this study, we performed indirect meta-analysis comparing SGLT2 inhibitors and DPP4 inhibitors added to insulin

  7. Effect of Continuous Positive Airway Pressure Therapy on Glycemic Excursions and Insulin Sensitivity in Patients with Obstructive Sleep Apnea-hypopnea Syndrome and Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Li-Xin Guo

    2015-01-01

    Conclusions: CPAP therapy may have a beneficial effect on improving not only blood glucose but also upon insulin sensitivity in T2DM patients with OSAHS. This suggests that CPAP may be an effective treatment for T2DM in addition to intensive diabetes management.

  8. Increased prandial air swallowing and postprandial gas-liquid reflux among patients refractory to proton pump inhibitor therapy.

    Science.gov (United States)

    Bravi, Ivana; Woodland, Philip; Gill, Ravinder S; Al-Zinaty, Mohannad; Bredenoord, Albert J; Sifrim, Daniel

    2013-07-01

    Many patients with gastroesophageal reflux disease (GERD) have persistent reflux despite treatment with proton pump inhibitors (PPIs). Mixed gas-liquid reflux events are more likely to be perceived as symptomatic. We used esophageal impedance monitoring to investigate whether esophageal gas is processed differently among patients with GERD who do and do not respond to PPI therapy. We performed a prospective study of 44 patients with typical reflux symptoms with high levels of esophageal acid exposure during a 24-hour period; 18 patients were fully responsive, and 26 did not respond to PPI therapy. Twenty-four-hour pH impedance recordings were analyzed for fasting and prandial air swallows and reflux characteristics, including the presence of gas in the refluxate. PPI-refractory patients had a higher number (83.1 ± 12.7 vs 47.8 ± 7.3, P gas-liquid reflux. Symptoms of PPI-refractory patients were more often preceded by mixed gas-liquid reflux events than those of PPI responders. Fasting air swallowing and other reflux characteristics did not differ between patients who did and did not respond to PPIs. Some patients with GERD who do not respond to PPI therapy swallow more air at mealtime than those who respond to PPIs and also have more reflux episodes that contain gas. These factors, combined with mucosal sensitization by previous exposure to acid, could affect perception of symptoms. These patients, who can be identified on standard 24-hour pH impedance monitoring, might be given behavioral therapy to reduce mealtime air swallowing. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  9. A two year observational study of nicotinamide and intensive insulin therapy in patients with recent onset type 1 diabetes mellitus.

    Science.gov (United States)

    Crinó, A; Schiaffini, R; Ciampalini, P; Suraci, M C; Manfrini, S; Visalli, N; Matteoli, M C; Patera, P; Buzzetti, R; Guglielmi, C; Spera, S; Costanza, F; Fioriti, E; Pitocco, D; Pozzilli, P

    2005-08-01

    A number of trials have evaluated residual beta-cell function in patients with recent onset type 1 diabetes mellitus (DM1) treated with nicotinamide in addition to intensive insulin therapy (IIT). In most studies, only a slight decline of C-peptide secretion was observed 12 months after diagnosis; however, no data is available on C-peptide secretion and metabolic control in patients continuing nicotinamide and IIT for up to 2 years after diagnosis. We retrospectively analysed data from 25 patients (mean age 14.7 years +/- 5 SD) with DM1 in whom nicotinamide at a dose of 25 mg/kg b. wt. was added from diagnosis (< 4 weeks) to IIT (three injections of regular insulin at meals + one NPH at bed time) and continued for up to 2 years after diagnosis. Data were also analysed from patients (n = 27) in whom IIT was introduced at diagnosis and who were similarly followed for 2 years. Baseline C-peptide as well as insulin dose and HbA1c levels were evaluated at 12 and 24 months after diagnosis. In the course of the follow-up, patients on nicotinamide + IIT or IIT alone did not significantly differ in terms of C-peptide secretion (values at 24 months in the two groups were 0.19 +/- 0.24 nM vs 0.19 +/- 0.13 nM, respectively). Insulin requirement (0.6 +/- 0.3 U/kg/day vs 0.7 +/- 0.2 U/kg/day at 24 months, respectively) did not differ between the two groups. However, HbA1c was significantly lower 2 years after diagnosis in patients treated with nicotinamide + IIT (6.09 +/- 0.9% vs 6.98 +/- 0.9%, respectively, p < 0.01). No adverse effects were observed in patients receiving nicotinamide for 2 years. Implementation of IIT with the addition of nicotinamide at diagnosis continued for 2 years improves metabolic control as assessed by HbA1c. In both nicotinamide and control patients, no decline in C-peptide was detected 2 years after diagnosis, indicating that IIT preserves C-peptide secretion. We conclude that nicotinamide + IIT at diagnosis of DM1 prolonged for up to 2 years can be

  10. Metformin versus placebo in combination with insulin analogues in patients with type 2 diabetes mellitus-the randomised, blinded Copenhagen Insulin and Metformin Therapy (CIMT) trial

    DEFF Research Database (Denmark)

    Lundby-Christensen, Louise; Tarnow, Lise; Boesgaard, Trine W

    2016-01-01

    OBJECTIVE: To assess the effect of metformin versus placebo both in combination with insulin analogue treatment on changes in carotid intima-media thickness (IMT) in patients with type 2 diabetes. DESIGN AND SETTING: Investigator-initiated, randomised, placebo-controlled trial with a 2×3 factorial...... design conducted at eight hospitals in Denmark. PARTICIPANTS AND INTERVENTIONS: 412 participants with type 2 diabetes (glycated haemoglobin (HbA1c) ≥7.5% (≥58 mmol/mol); body mass index >25 kg/m2) were in addition to open-labelled insulin treatment randomly assigned 1:1 to 18 months blinded metformin (1...... weight gain, and smaller insulin dose compared with placebo plus insulin. However, the trial only reached 46% of the planned sample size and lack of power may therefore have affected our results. TRIAL REGISTRATION NUMBER: NCT00657943; Results....

  11. InsuOnline, an Electronic Game for Medical Education on Insulin Therapy: A Randomized Controlled Trial With Primary Care Physicians.

    Science.gov (United States)

    Diehl, Leandro Arthur; Souza, Rodrigo Martins; Gordan, Pedro Alejandro; Esteves, Roberto Zonato; Coelho, Izabel Cristina Meister

    2017-03-09

    Most patients with diabetes mellitus (DM) are followed by primary care physicians, who often lack knowledge or confidence to prescribe insulin properly. This contributes to clinical inertia and poor glycemic control. Effectiveness of traditional continuing medical education (CME) to solve that is limited, so new approaches are required. Electronic games are a good option, as they can be very effective and easily disseminated. The objective of our study was to assess applicability, user acceptance, and educational effectiveness of InsuOnline, an electronic serious game for medical education on insulin therapy for DM, compared with a traditional CME activity. Primary care physicians (PCPs) from South of Brazil were invited by phone or email to participate in an unblinded randomized controlled trial and randomly allocated to play the game InsuOnline, installed as an app in their own computers, at the time of their choice, with minimal or no external guidance, or to participate in a traditional CME session, composed by onsite lectures and cases discussion. Both interventions had the same content and duration (~4 h). Applicability was assessed by the number of subjects who completed the assigned intervention in each group. Insulin-prescribing competence (factual knowledge, problem-solving skills, and attitudes) was self-assessed through a questionnaire applied before, immediately after, and 3 months after the interventions. Acceptance of the intervention (satisfaction and perceived importance for clinical practice) was also assessed immediately after and 3 months after the interventions, respectively. Subjects' characteristics were similar between groups (mean age 38, 51.4% [69/134] male). In the game group, 69 of 88 (78%) completed the intervention, compared with 65 of 73 (89%) in the control group, with no difference in applicability. Percentage of right answers in the competence subscale, which was 52% at the baseline in both groups, significantly improved

  12. InsuOnline, an Electronic Game for Medical Education on Insulin Therapy: A Randomized Controlled Trial With Primary Care Physicians

    Science.gov (United States)

    2017-01-01

    Background Most patients with diabetes mellitus (DM) are followed by primary care physicians, who often lack knowledge or confidence to prescribe insulin properly. This contributes to clinical inertia and poor glycemic control. Effectiveness of traditional continuing medical education (CME) to solve that is limited, so new approaches are required. Electronic games are a good option, as they can be very effective and easily disseminated. Objective The objective of our study was to assess applicability, user acceptance, and educational effectiveness of InsuOnline, an electronic serious game for medical education on insulin therapy for DM, compared with a traditional CME activity. Methods Primary care physicians (PCPs) from South of Brazil were invited by phone or email to participate in an unblinded randomized controlled trial and randomly allocated to play the game InsuOnline, installed as an app in their own computers, at the time of their choice, with minimal or no external guidance, or to participate in a traditional CME session, composed by onsite lectures and cases discussion. Both interventions had the same content and duration (~4 h). Applicability was assessed by the number of subjects who completed the assigned intervention in each group. Insulin-prescribing competence (factual knowledge, problem-solving skills, and attitudes) was self-assessed through a questionnaire applied before, immediately after, and 3 months after the interventions. Acceptance of the intervention (satisfaction and perceived importance for clinical practice) was also assessed immediately after and 3 months after the interventions, respectively. Results Subjects’ characteristics were similar between groups (mean age 38, 51.4% [69/134] male). In the game group, 69 of 88 (78%) completed the intervention, compared with 65 of 73 (89%) in the control group, with no difference in applicability. Percentage of right answers in the competence subscale, which was 52% at the baseline in both

  13. Prevalence and Geographical Distribution of Insulin Pump Therapy in the Central Denmark Region and its Association with Metabolic Parameters

    DEFF Research Database (Denmark)

    Kampmann, Ulla; Ring Madsen, Lene; Bjerg, Lasse

    2018-01-01

    /mol) versus 8.0 % (64 mmol/mol)) in unadjusted analyses. After adjustment for clinically relevant characteristics the difference between CSII and MDI-treated patients was attenuated, but remained statistically significant. CONCLUSION: The distribution of CSII differed markedly between hospitals and CSII users...

  14. Impact of gastro-oesophageal reflux disease on work productivity despite therapy with proton pump inhibitors in Germany

    Directory of Open Access Journals (Sweden)

    Gross M

    2010-03-01

    Full Text Available Abstract Background Gastro-oesophageal reflux disease (GERD is a common disorder with consequences for the patient's health-related quality of life (HRQoL. In Germany, few data are available on the impact of GERD on work-related productivity. Aim To study the impact of GERD on work productivity despite proton pump inhibitor (PPI therapy and the association between productivity and symptom duration, severity, and HRQoL. Methods Retrospective data from randomly selected patients with chronic GERD symptoms, treated by office-based general practitioners or general internists with routine clinical care, were analyzed together with information from self-administered instruments assessing work productivity (WPAI-GERD, symptoms (RDQ, and HRQoL (QOLRAD. Results Reduced productivity was reported by 152 of 249 patients (61.0%, although 89.5% of them were treated with PPI. The reduction in work productivity was 18.5% in all patients and 30.3% in those with reduced productivity. Patients with impaired productivity showed a significantly lower HRQoL and more-severe symptoms of reflux disease. In all patients, the mean sick leave attributable to reflux symptoms was 0.6 hours in the previous seven days and 1.4 work days in the previous three months. Conclusion GERD has a substantial impact on work productivity in Germany, even in patients receiving routine clinical care and PPI therapy.

  15. Clinical course after five years of insulin therapy in patients with type 2 diabetes in Spain: results of the EDIN study.

    Science.gov (United States)

    Rodríguez, Angel; Tofe, Santiago; Reviriego, Jesus

    2014-01-01

    The primary study objective was to assess the proportion of patients with type 2 diabetes and an HbA1c value ≤ 6.5% from the start of insulin therapy to five years later in the outpatient setting in Spain. This was an observational, multicenter, naturalistic study with retrospective collection of clinical data. Investigators were endocrinologists or internal medicine specialists from all over Spain. During standard clinical care, patients started insulin therapy, which was continued for at least 5 years. The clinical records of 405 patients were reviewed. The final analysis set included records from 346 patients. At baseline (start of insulin therapy), 51.2% of patients were female; mean (SD) age was 64.6 (9.0) years; body mass index, 29.8 (4-5) kg/m(2); time since diagnosis, 8.8 (6.8) years; HbA1c, 9.4% (1.5); fasting glucose, 223.7 (55.9) mg/dL; and mean 2-hour postprandial glucose, 293.6 (71.0) mg/dL. When insulin therapy was started, 1.0% of patients had an HbA1c value ≤ 6.5%. At 5 years, 10.3% of patients achieved the HbA1c goal of ≤ 6.5% (mean, 7.72%). All glucose parameters (HbA1c, fasting glucose, and 2-hour postprandial glucose) improved at 5 years as compared to values at the start of insulin therapy. Glucose parameters improved over time in patients with type 2 diabetes in this naturalistic study. However, blood glucose control exceeded the internationally recommended target values. These results therefore suggest that there is still some margin for improvement in outpatient care in Spain. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  16. State of the Art Review: Emerging Therapies: The Use of Insulin Sensitizers in the Treatment of Adolescents with Polycystic Ovary Syndrome (PCOS).

    Science.gov (United States)

    Geller, David H; Pacaud, Danièle; Gordon, Catherine M; Misra, Madhusmita

    2011-08-26

    PCOS, a heterogeneous disorder characterized by cystic ovarian morphology, androgen excess, and/or irregular periods, emerges during or shortly after puberty. Peri- and post-pubertal obesity, insulin resistance and consequent hyperinsulinemia are highly prevalent co-morbidities of PCOS and promote an ongoing state of excess androgen. Given the relationship of insulin to androgen excess, reduction of insulin secretion and/or improvement of its action at target tissues offer the possibility of improving the physical stigmata of androgen excess by correction of the reproductive dysfunction and preventing metabolic derangements from becoming entrenched. While lifestyle changes that concentrate on behavioral, dietary and exercise regimens should be considered as first line therapy for weight reduction and normalization of insulin levels in adolescents with PCOS, several therapeutic options are available and in wide use, including oral contraceptives, metformin, thiazolidenediones and spironolactone. Overwhelmingly, the data on the safety and efficacy of these medications derive from the adult PCOS literature. Despite the paucity of randomized control trials to adequately evaluate these modalities in adolescents, their use, particularly that of metformin, has gained popularity in the pediatric endocrine community. In this article, we present an overview of the use of insulin sensitizing medications in PCOS and review both the adult and (where available) adolescent literature, focusing specifically on the use of metformin in both mono- and combination therapy.

  17. State of the Art Review: Emerging Therapies: The Use of Insulin Sensitizers in the Treatment of Adolescents with Polycystic Ovary Syndrome (PCOS)

    Science.gov (United States)

    2011-01-01

    PCOS, a heterogeneous disorder characterized by cystic ovarian morphology, androgen excess, and/or irregular periods, emerges during or shortly after puberty. Peri- and post-pubertal obesity, insulin resistance and consequent hyperinsulinemia are highly prevalent co-morbidities of PCOS and promote an ongoing state of excess androgen. Given the relationship of insulin to androgen excess, reduction of insulin secretion and/or improvement of its action at target tissues offer the possibility of improving the physical stigmata of androgen excess by correction of the reproductive dysfunction and preventing metabolic derangements from becoming entrenched. While lifestyle changes that concentrate on behavioral, dietary and exercise regimens should be considered as first line therapy for weight reduction and normalization of insulin levels in adolescents with PCOS, several therapeutic options are available and in wide use, including oral contraceptives, metformin, thiazolidenediones and spironolactone. Overwhelmingly, the data on the safety and efficacy of these medications derive from the adult PCOS literature. Despite the paucity of randomized control trials to adequately evaluate these modalities in adolescents, their use, particularly that of metformin, has gained popularity in the pediatric endocrine community. In this article, we present an overview of the use of insulin sensitizing medications in PCOS and review both the adult and (where available) adolescent literature, focusing specifically on the use of metformin in both mono- and combination therapy. PMID:21899727

  18. State of the Art Review: Emerging Therapies: The Use of Insulin Sensitizers in the Treatment of Adolescents with Polycystic Ovary Syndrome (PCOS

    Directory of Open Access Journals (Sweden)

    Gordon Catherine M

    2011-08-01

    Full Text Available Abstract PCOS, a heterogeneous disorder characterized by cystic ovarian morphology, androgen excess, and/or irregular periods, emerges during or shortly after puberty. Peri- and post-pubertal obesity, insulin resistance and consequent hyperinsulinemia are highly prevalent co-morbidities of PCOS and promote an ongoing state of excess androgen. Given the relationship of insulin to androgen excess, reduction of insulin secretion and/or improvement of its action at target tissues offer the possibility of improving the physical stigmata of androgen excess by correction of the reproductive dysfunction and preventing metabolic derangements from becoming entrenched. While lifestyle changes that concentrate on behavioral, dietary and exercise regimens should be considered as first line therapy for weight reduction and normalization of insulin levels in adolescents with PCOS, several therapeutic options are available and in wide use, including oral contraceptives, metformin, thiazolidenediones and spironolactone. Overwhelmingly, the data on the safety and efficacy of these medications derive from the adult PCOS literature. Despite the paucity of randomized control trials to adequately evaluate these modalities in adolescents, their use, particularly that of metformin, has gained popularity in the pediatric endocrine community. In this article, we present an overview of the use of insulin sensitizing medications in PCOS and review both the adult and (where available adolescent literature, focusing specifically on the use of metformin in both mono- and combination therapy.

  19. Efficacy and safety of teneligliptin in addition to insulin therapy in type 2 diabetes mellitus patients on hemodialysis evaluated by continuous glucose monitoring.

    Science.gov (United States)

    Yajima, Takahiro; Yajima, Kumiko; Hayashi, Makoto; Takahashi, Hiroshi; Yasuda, Keigo

    2016-12-01

    Appropriate glycemic control without hypoglycemia is important in patients with type 2 diabetes on hemodialysis. Teneligliptin, a novel dipeptidyl peptidase-4 inhibitor, can be used without dose adjustment for these patients. Using continuous glucose monitoring (CGM), we evaluated the efficacy and safety of adding teneligliptin to insulin therapy. Twenty-one type 2 diabetes mellitus patients on hemodialysis treated with insulin were enrolled. After the adjustment of insulin dose, their blood glucose level was monitored by CGM. Insulin dose was reduced after teneligliptin administration. The median total daily insulin dose significantly reduced from 18 (9-24)U to 6 (0-14)U (p1). Maximum, mean, and standard deviation of blood glucose level on the hemodialysis and non-hemodialysis days did not change after teneligliptin administration. However, minimum blood glucose level was significantly elevated on the hemodialysis day after teneligliptin administration (from 3.9±1.0mmol/L to 4.4±0.9mmol/L, p=0.040). The incidence of asymptomatic hypoglycemia on the hemodialysis day detected by CGM significantly decreased from 38.1% to 19.0% (p=0.049). Teneligliptin may contribute toward reducing the total daily insulin dose and preventing hypoglycemic events on the hemodialysis day in type 2 diabetes mellitus patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Evidence-based support for the use of proton pump inhibitors in cancer therapy.

    Science.gov (United States)

    Fais, Stefano

    2015-11-24

    'We can only cure what we can understand first', said Otto H. Warburg, the 1931 Nobel laureate for his discovery on tumor metabolism. Unfortunately, we still don't know too much the mechanisms underlying of cancer development and progression. One of the unsolved mystery includes the strategies that cancer cells adopt to cope with an adverse microenvironment. However, we knew, from the Warburg's discovery, that through their metabolism based on sugar fermentation, cancer cells acidify their microenvironment and this progressive acidification induces a selective pressure, leading to development of very malignant cells entirely armed to survive in the hostile microenvironment generated by their own metabolism. One of the most mechanism to survive to the acidic tumor microenvironment are proton exchangers not allowing intracellular acidification through a continuous elimination of H(+) either outside the cells or within the internal vacuoles. This article wants to comment a translational process through which from the preclinical demonstration that a class of proton pump inhibitors (PPI) exploited worldwide for peptic ulcer treatment and gastroprotection are indeed chemosensitizers as well, we have got to the clinical proof of concept that PPI may well be included in new anti-cancer strategies, and with a solid background and rationale.

  1. Future of newer basal insulin

    OpenAIRE

    Madhu, S. V.; Velmurugan, M.

    2013-01-01

    Basal insulin have been developed over the years. In recent times newer analogues have been added to the armanentarium for diabetes therapy. This review specifically reviews the current status of different basal insulins

  2. Safety and Efficacy in Early Insulin Initiation as Comprehensive Therapy for Patients with Type 2 Diabetes in Primary Health Care Centers

    Directory of Open Access Journals (Sweden)

    Agung Pranoto

    2015-04-01

    Full Text Available Aim: to analyze the safety and efficacy of early insulin initiation therapy for patients with type 2 diabetes mellitus (T2DM in primary health care provided by general practitioners (GPs in Surabaya, East Java, Indonesia. Methods: pre-post study of ninety nine diabetic patients without previous insulin treatment with HbA1c levels >8% were involved in this study. The study was conducted in 10 primary health care centers in Surabaya between October 2011 to June 2012. Each patient received insulin therapy for 12 weeks. Laboratory examination was performed for each patient including fasting plasma glucose (FPG, 2 hours post-prandial plasma glucose (2hPPG and HbA1c examination before and after the study. Self monitoring blood glucose (SMBG examination was conducted in order to adjust the insulin dose and prevent the incidence of hypoglycemia. Data was statistically analyzed using paired-T test. Results: FPG level was decreased from baseline data (209 mg/dL to 152.07 mg/dL at the end of the study (Δ56.93 mg/dl; p=0.0001. The average of 2hPPG level was also decreased from 313.00 mg/dl to 220.72 mg/dL (Δ 92.28 mg/dL; p=0.0001. HbA1c was reduced from 11.60% at baseline to 8.95% at the end of study (Δ 2.65%; p=0.0001. Hypoglycemia was found in 6 patients (6.06% in this study, but all events were mild and did not need to be admitted to hospital. Conclusion: the safety of insulin therapy iniatiation might be provided by GPs at primary health centers with significant efficacy and minimal side effects. Key words: insulin, general practioner, primary health center.

  3. Insulin-like growth factor-I gene therapy reverses morphologic changes and reduces hyperprolactinemia in experimental rat prolactinomas

    Directory of Open Access Journals (Sweden)

    Bracamonte Maria I

    2008-01-01

    Full Text Available Abstract Background The implementation of gene therapy for the treatment of pituitary tumors emerges as a promising complement to surgery and may have distinct advantages over radiotherapy for this type of tumors. Up to now, suicide gene therapy has been the main experimental approach explored to treat experimental pituitary tumors. In the present study we assessed the effectiveness of insulin-like growth factor I (IGF-I gene therapy for the treatment of estrogen-induced prolactinomas in rats. Results Female Sprague Dawley rats were subcutaneously implanted with silastic capsules filled with 17-β estradiol (E2 in order to induce pituitary prolactinomas. Blood samples were taken at regular intervals in order to measure serum prolactin (PRL. As expected, serum PRL increased progressively and 23 days after implanting the E2 capsules (Experimental day 0, circulating PRL had undergone a 3–4 fold increase. On Experimental day 0 part of the E2-implanted animals received a bilateral intrapituitary injection of either an adenoviral vector expressing the gene for rat IGF-I (RAd-IGFI, or a vector (RAd-GFP expressing the gene for green fluorescent protein (GFP. Seven days post vector injection all animals were sacrificed and their pituitaries morphometrically analyzed to evaluate changes in the lactotroph population. RAd-IGFI but not RAd-GFP, induced a significant fall in serum PRL. Furthermore, RAd-IGFI but not RAd-GFP significantly reversed the increase in lactotroph size (CS and volume density (VD induced by E2 treatment. Conclusion We conclude that IGF-I gene therapy constitutes a potentially useful intervention for the treatment of prolactinomas and that bioactive peptide gene delivery may open novel therapeutic avenues for the treatment of pituitary tumors.

  4. Daily insulin requirement of children and adolescents with type 1 diabetes: effect of age, gender, body mass index and mode of therapy.

    Science.gov (United States)

    Wiegand, Susanna; Raile, Klemens; Reinehr, Thomas; Hofer, Sabine; Näke, Andrea; Rabl, Wolfgang; Holl, Reinhard W

    2008-04-01

    The purpose of this study was to generate insulin dose (ID) percentiles for children and adolescents with type 1 diabetes mellitus (DM1) having the opportunity to assess this important parameter in relation to age and sex. Daily IDs per weight (ID/kg) were recorded in 22,177 patients with DM1 (3-25 years of age, DM1 duration of more than 2 years, 48% female) and ID percentiles (ID-Perc) were created statistically. The ID-Perc were compared between male and female, and between multiple insulin injection therapy (MIT) and continuous s.c. insulin infusion (CSII). A multivariate regression analysis was performed for ID in the third year of DM1 with ID/kg, body weight, age, gender, and insulin delivery regimen as variables. The 50th ID-Perc (P50) varied among 0.67 IU/kg (age 3 years), 0.93 IU/kg (13 years), and 0.70 IU/kg (23 years) increasing from early childhood to adolescence and decreasing toward adulthood. Highest P50 ID was found at 12 years in females (0.94 IU/kg) and at 14 years in males (0.92 IU/kg). Using ICT, the ID was significantly higher compared with CSII (P50: 0.94 IU/kg versus 0.79 IU/kg at 13 years). In multivariate regression analysis, ID was significantly (P>0.001) associated with age, gender, and insulin delivery regime. The ID-Perc were significantly different during various periods of childhood and were influenced by gender, body weight, and insulin injection regimes. Therefore, the presented data 1) provide evidence to interpret individual ID in children and adolescents with DM1 and 2) more specifically identify children with unusually high (insulin resistance and non-compliance) or low (MODY and persistent remission) insulin requirement.

  5. High-Protein Intake during Weight Loss Therapy Eliminates the Weight-Loss-Induced Improvement in Insulin Action in Obese Postmenopausal Women

    OpenAIRE

    Gordon I. Smith; Jun Yoshino; Shannon C. Kelly; Dominic N. Reeds; Adewole Okunade; Bruce W. Patterson; Samuel Klein; Bettina Mittendorfer

    2016-01-01

    High-protein (HP) intake during weight loss (WL) therapy is often recommended because it reduces the loss of lean tissue mass. However, HP intake could have adverse effects on metabolic function, because protein ingestion reduces postprandial insulin sensitivity. In this study, we compared the effects of ∼10% WL with a hypocaloric diet containing 0.8 g protein/kg/day and a hypocaloric diet containing 1.2 g protein/kg/day on muscle insulin action in postmenopausal women with obesity. We found ...

  6. Proton-pump inhibitor therapy induces acid-related symptoms in healthy volunteers after withdrawal of therapy

    DEFF Research Database (Denmark)

    Reimer, Christina; Søndergaard, Bo; Hilsted, Linda

    2009-01-01

    -controlled trial with 120 healthy volunteers was conducted. Participants were randomized to 12 weeks of placebo or 8 weeks of esomeprazole 40 mg/d followed by 4 weeks with placebo. The Gastrointestinal Symptom Rating Scale (GSRS) was filled out weekly. A score of >2 on 1 of the questions regarding heartburn, acid...... dyspepsia, heartburn, or acid regurgitation in the PPI group was 13 of 59 (22%) at week 10, 13 of 59 (22%) at week 11, and 12 of 58 (21%) at week 12. Corresponding figures in the placebo group were 7% at week 10 (P = .034), 5% at week 11 (P = .013), and 2% at week 12 (P = .001). CONCLUSIONS: PPI therapy...

  7. Effects of insulin therapy on porosity, non-enzymatic glycation and mechanical competence in the bone of rats with type 2 diabetes mellitus.

    Science.gov (United States)

    Campbell, G M; Tiwari, S; Picke, A-K; Hofbauer, C; Rauner, M; Morlock, M M; Hofbauer, L C; Glüer, C-C

    2016-10-01

    Type 2 diabetes mellitus increases skeletal fragility; however, the contributing mechanisms and optimal treatment strategies remain unclear. We studied the effects of diabetes and insulin therapy on non-enzymatic glycation (NEG), cortical porosity (Ct.Po) and biomechanics of the bone tissue in Zucker Diabetic Fatty (ZDF) rats. Eleven-week old ZDF diabetic and non-diabetic rats were given insulin to achieve glycaemic control or vehicle seven days per week over twelve weeks (insulin dose adapted individually 0.5 international units (IU) at week 1 to 13.0IU at week 12). The right femora were excised, micro-CT scanned, and tested in 3-point bending to measure biomechanics. NEG of the midshaft was determined from bulk fluorescence. Diabetes led to increased NEG (+50.1%, p=0.001) and Ct.Po (+22.9%, p=0.004), as well as to reduced mechanical competence (max. stress: -14.2%, p=0.041, toughness: -29.7%, p=0.016) in the bone tissue. NEG and Ct.Po both correlated positively to serum glucose (NEG: R(2)=0.41, p1, Ct.Po: R(2)=0.34, p=0.003) and HbA1c (NEG: R(2)=0.42, p1, Ct.Po: R(2)=0.28, p=0.008) levels, while NEG correlated negatively with bone biomechanics (elastic modulus: R(2)=0.21, p=0.023, yield stress: R(2)=0.17, p=0.047). Twelve weeks of insulin therapy had no significant effect on NEG or Ct.Po, and was unable to improve the mechanical competence of the bone tissue. A reduction of mechanical competence was observed in the bone tissue of the diabetic rats, which was explained in part by increased collagen NEG. Twelve weeks of insulin therapy did not alter NEG, Ct.Po or bone biomechanics. However, significant correlations between NEG and serum glucose and HbA1c were observed, both of which were reduced with insulin therapy. This suggests that a longer duration of insulin therapy may be required to reduce the NEG of the bone collagen and restore the mechanical competence of diabetic bone. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Antiretroviral therapy-induced insulin resistance and oxidative deoxy nucleic acid damage in human immunodeficiency virus-1 patients

    Directory of Open Access Journals (Sweden)

    Vaishali Kolgiri Honnapurmath

    2017-01-01

    Full Text Available Background and Objectives: Insulin resistance (IR is frequent in human immunodeficiency virus (HIV infection and may be related to antiretroviral therapy (ART. Increased oxidative stress parameters and carbonyl protein are linked to insulin sensitivity. The present study is aimed to determine IR, its association with oxidative deoxy nucleic acid (DNA damage in HIV-1-infected patients with different ART status. Materials and Methods: In this case–control study, a total 600 subjects were included. We used plasma levels of the oxidized base, 8-hydroxy-2-deoxyguanosine (8-OHdG, as our biomarker of oxidative DNA damage. 8-OHdG was measured with the highly sensitive 8-OHdG check enzyme-linked immunosorbent assay kit. IR was determined using homeostasis model assessment. Results: All subjects were randomly selected and grouped as HIV-negative (control group (n = 300, HIV-positive without ART (n = 100, HIV-positive with ART first line (n = 100, and HIV-positive with ART second line (n = 100. IR and oxidative DNA damage were significantly higher in HIV-positive patients with second-line ART and HIV-positive patients with first-line ART than ART-naive patients. In a linear regression analysis, increased IR was positively associated with the increased DNA damage (odds ratio: 3.052, 95% confidence interval: 2.595–3.509 P < 0.001. Interpretation and Conclusions: In this study, we observed that ART plays a significant role in the development of IR and oxidative DNA damage in HIV-positive patients taking ART. Awareness and knowledge of these biomarkers may prove helpful to clinicians while prescribing ART to HIV/AIDS patients. Larger studies are warranted to determine the exact role of ART in the induction of IR and DNA damage.

  9. The effect of intensive insulin therapy on the insulin-regulatable glucose transporter (GLUT4) expression in skeletal muscle in type 1 diabetes

    DEFF Research Database (Denmark)

    Andersen, P H; Vestergaard, H; Lund, S

    1993-01-01

    h given to patients with Type 1 diabetes in poor metabolic control was associated with an adaptive regulation of GLUT4 mRNA and protein levels in vastus lateralis muscle. Nine Type 1 diabetic patients with a mean HbA1c of 10.3% were included in the protocol. After intensified treatment with soluble.......54). These results suggest, that in spite of evidence that high insulin levels affect GLUT4 expression in muscle, changes in serum insulin within the physiological range do not play a major role in the short-term regulation of GLUT4 expression in Type 1 diabetic patients....

  10. Possible applications of gliptins (dipeptidyl peptidase-4 inhibitors in patients with type 2 diabetes mellitus on the various modes of insulin therapy

    Directory of Open Access Journals (Sweden)

    Gagik Radikovich Galstyan

    2015-10-01

    Full Text Available The evidence for DPP-4 inhibitors effectiveness at the late stages of type 2 diabetes mellitus (T2DM are still growing. This is particularly important for those patients who receive insulin without adequately glycemic control. This publication provides the overview of studies which demonstrate high efficacy of Vildagliptin in reducing the blood glucose level in patients with hight duration of T2DM and insulin therapy. DPP-4 inhibitors normalize basal and postprandial glucagon secretion with pancreas α-cells that helps to provide better glycemic control and to reduce a risk of hypoglycemia. Besides, there are very interesting data for Vildagliptin to reduce insulin requirement in T2DM patients in addition to HbA1clevel decrease.

  11. Cost-effectiveness analysis of exenatide twice daily (BID) vs insulin glargine once daily (QD) as add-on therapy in Chinese patients with Type 2 diabetes mellitus inadequately controlled by oral therapies.

    Science.gov (United States)

    Deng, Jing; Gu, Shuyan; Shao, Hui; Dong, Hengjin; Zou, Dajin; Shi, Lizheng

    2015-01-01

    To estimate cost-effectiveness of exenatide twice daily (BID) vs insulin glargine once daily (QD) as add-on therapy in Chinese type 2 diabetes patients not well controlled by oral anti-diabetic (OAD) agents. The Cardiff model was populated with data synthesized from three head-to-head randomized clinical trials of up to 30 weeks in China comparing exenatide BID vs insulin glargine as add-on therapies to oral therapies in the Chinese population. The Cardiff model generated outputs including macrovascular and microvascular complications, diabetes-specific mortality, costs, and quality-adjusted life years (QALYs). Cost and QALYs were estimated with a time horizon of 40 years at a discount rate of 3% from a societal perspective. Compared with insulin glargine plus OAD treatments, patients on exenatide BID plus OAD gained 1.88 QALYs, at an incremental cost saving of Chinese Renminbi (RMB) 114,593 (i.e., cost saving of RMB 61078/QALY). The cost-effectiveness results were robust to various sensitivity analyses including probabilistic sensitivity analysis. The variables with the most impact on incremental cost-effectiveness ratio included HbA1c level at baseline, health utilities decrement, and BMI at baseline. Compared with insulin glargine QD, exenatide BID as add-on therapy to OAD is a cost-effective treatment in Chinese patients inadequately controlled by OAD treatments.

  12. Circadian hormone profiles and insulin sensitivity in patients with Addison's disease: a comparison of continuous subcutaneous hydrocortisone infusion with conventional glucocorticoid replacement therapy.

    Science.gov (United States)

    Björnsdottir, Sigridur; Øksnes, Marianne; Isaksson, Magnus; Methlie, Paal; Nilsen, Roy M; Hustad, Steinar; Kämpe, Olle; Hulting, Anna-Lena; Husebye, Eystein S; Løvås, Kristian; Nyström, Thomas; Bensing, Sophie

    2015-07-01

    Conventional glucocorticoid replacement therapy in patients with Addison's disease (AD) is unphysiological with possible adverse effects on mortality, morbidity and quality of life. The diurnal cortisol profile can likely be restored by continuous subcutaneous hydrocortisone infusion (CSHI). The aim of this study was to compare circadian hormone rhythms and insulin sensitivity in conventional thrice-daily regimen of glucocorticoid replacement therapy with CSHI treatment in patients with AD. An open, randomized, two-period, 12-week crossover multicentre trial in Norway and Sweden. Ten Norwegian patients were admitted for 24-h sampling of hormone profiles. Fifteen Swedish patients underwent euglycaemic-hyperinsulinaemic clamp. Thrice-daily regimen of oral hydrocortisone (OHC) and CSHI treatment. We measured the circadian rhythm of cortisol, adrenocorticotropic hormone (ACTH), growth hormone (GH), insulin-like growth factor-1, (IGF-1), IGF-binding protein-3 (IGFBP-3), glucose, insulin and triglycerides during OHC and CSHI treatment. Euglycaemic-hyperinsulinaemic clamp was used to assess insulin sensitivity. Continuous subcutaneous hydrocortisone infusion provided a more physiological circadian cortisol curve including a late-night cortisol surge. ACTH levels showed a near normal circadian variation for CSHI. CSHI prevented a continuous decrease in glucose during the night. No difference in insulin sensitivity was observed between the two treatment arms. Continuous subcutaneous hydrocortisone infusion replacement re-established a circadian cortisol rhythm and normalized the ACTH levels. Patients with CSHI replacement had a more stable night-time glucose level compared with OHC without compromising insulin sensitivity. Thus, restoring night-time cortisol levels might be advantageous for patients with AD. © 2015 John Wiley & Sons Ltd.

  13. Cost-effectiveness of exenatide twice daily vs insulin glargine as add-on therapy to oral antidiabetic agents in patients with type 2 diabetes in China.

    Science.gov (United States)

    Gu, Shuyan; Wang, Xiaoyong; Qiao, Qing; Gao, Weiguo; Wang, Jian; Dong, Hengjin

    2017-12-01

    To estimate the long-term cost-effectiveness of exenatide twice daily vs insulin glargine once daily as add-on therapy to oral antidiabetic agents (OADs) for Chinese patients with type 2 diabetes (T2DM). The Cardiff Diabetes Model was used to simulate disease progression and estimate the long-term effects of exenatide twice daily vs insulin glargine once daily. Patient profiles and treatment effects required for the model were obtained from literature reviews (English and Chinese databases) and from a meta-analysis of 8 randomized controlled trials comparing exenatide twice daily with insulin glargine once daily add-on to OADs for T2DM in China. Medical expenditure data were collected from 639 patients with T2DM (aged ≥18 years) with and without complications incurred between January 1, 2014 and December 31, 2015 from claims databases in Shandong, China. Costs (2014 Chinese Yuan [¥]) and benefits were estimated, from the payers' perspective, over 40 years at a discount rate of 3%. A series of sensitivity analyses were performed. Patients on exenatide twice daily + OAD had a lower predicted incidence of most cardiovascular and hypoglycaemic events and lower total costs compared with those on insulin glargine once daily + OAD. A greater number of quality-adjusted life years (QALYs; 1.94) at a cost saving of ¥117 706 gained was associated with exenatide twice daily vs insulin glargine once daily. (i.e. cost saving of ¥60 764/QALY) per patient. In Chinese patients with T2DM inadequately controlled by OADs, exenatide twice daily is a cost-effective add-on therapy alternative to insulin glargine once daily, and may address the problem of an excess of medical needs resulting from weight gain and hypoglycaemia in T2DM treatment. © 2017 John Wiley & Sons Ltd.

  14. Efficacy of Additional Canagliflozin Administration to Type 2 Diabetes Patients Receiving Insulin Therapy: Examination of Diurnal Glycemic Patterns Using Continuous Glucose Monitoring (CGM).

    Science.gov (United States)

    Matsumura, Mihoko; Nakatani, Yuki; Tanka, Seiichi; Aoki, Chie; Sagara, Masaaki; Yanagi, Kazunori; Suzuki, Kunihiro; Aso, Yoshimasa

    2017-08-01

    The efficacy of administering a sodium-glucose cotransporter 2 inhibitor during insulin therapy has not been established. In this study, we examined its effects based on diurnal glycemic patterns using continuous glucose monitoring (CGM). The subjects were 15 patients who had received insulin therapy for 1 year or more. A CGM device was attached to all subjects for 1 week. The administration of canagliflozin at 100 mg was started 4 days after attachment. The mean glucose concentrations, standard deviation (SD), mean amplitude of glycemic excursions (MAGE), mean of daily difference of blood glucose (MODD), and area under the curve (AUC) (≥180, glucose concentrations decreased from 161.1 to 139.1 mg/dL (P AUC of ≥180, i.e., the total area of blood glucose levels at or above 180 on the blood glucose curve of CGM, decreased from 339.1 to 113.6 mg/dL (P AUC of blood glucose levels below 70 on the blood glucose curve of CGM, slightly decreased from 1.6 to 0.3 mg/dL (P = 0.08). The total number of basal insulin units decreased from 128 to 76, and that of bolus insulin decreased from 266 to 154; the dose of insulin could be markedly decreased. In addition, the mean 8-OHdG level decreased from 11.4 to 10.8 ng/mg Cre (P blood glucose changes in type 2 diabetes using insulin. In addition, the results suggest its antioxidant actions. University Hospital Medical Information Network (UMIN no. 000019429).

  15. What Are the Safety Considerations for Insulin Control for Athletes?

    Science.gov (United States)

    McDaniel, Larry W.; Olson, Sara; Gaudet, Laura; Jackson, Allen

    2010-01-01

    Athletes diagnosed with diabetes may have difficulty with their blood sugar levels fluctuating during intense exercise. Considerations for athletes with insulin concerns may range anywhere from exercise rehabilitation to the use of an automatic insulin pump. The automatic insulin pump is a small battery-operated device about the size of a pager.…

  16. Clinical and hemodynamic effects of intra-aortic balloon pump therapy in chronic heart failure patients with cardiogenic shock.

    Science.gov (United States)

    Fried, Justin A; Nair, Abhinav; Takeda, Koji; Clerkin, Kevin; Topkara, Veli K; Masoumi, Amirali; Yuzefpolskaya, Melana; Takayama, Hiroo; Naka, Yoshifumi; Burkhoff, Daniel; Kirtane, Ajay; Dimitrios Karmpaliotis, S M; Moses, Jeffrey; Colombo, Paolo C; Garan, A Reshad

    2018-03-20

    The role of the intra-aortic balloon pump (IABP) in acute decompensated heart failure (HF) with cardiogenic shock (CS) is largely undefined. In this study we sought to assess the hemodynamic and clinical response to IABP in chronic HF patients with CS and identify predictors of response to this device. We retrospectively reviewed all patients undergoing IABP implantation from 2011 to 2016 at our institution to identify chronic HF patients with acute decompensation and CS (cardiac index <2.2 liters/min/m 2 and systolic blood pressure <90 mm Hg or need for vasoactive medications to maintain this level). Clinical deterioration on IABP was defined as failure to bridge to either discharge on medical therapy or durable heart replacement therapy (HRT; durable left ventricular assist device or heart transplant) with IABP alone. We identified 132 chronic HF patients with IABP placed after decompensation with hemodynamic evidence of CS. Overall 30-day survival was 84.1%, and 78.0% of patients were successfully bridged to HRT or discharge without need for escalation of device support. The complication rate during IABP support was 2.3%. Multivariable analysis identified ischemic cardiomyopathy (odds ratio [OR] 3.24, 95% confidence interval [CI] 1.16 to 9.06; p = 0.03) and pulmonary artery pulsatility index (PAPi) <2.0 (OR 5.04, 95% CI 1.86 to 13.63; p = 0.001) as predictors of clinical deterioration on IABP. Overall outcomes with IABP in acute decompensated chronic HF patients are encouraging, and IABP is a reasonable first-line device for chronic HF patients with CS. Baseline right ventricular function, as measured by PAPi, is a major predictor of outcomes with IABP in this population. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  17. Association between proton pump inhibitor therapy and clostridium difficile infection: a contemporary systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Imad M Tleyjeh

    Full Text Available INTRODUCTION: Emerging epidemiological evidence suggests that proton pump inhibitor (PPI acid-suppression therapy is associated with an increased risk of Clostridium difficile infection (CDI. METHODS: Ovid MEDLINE, EMBASE, ISI Web of Science, and Scopus were searched from 1990 to January 2012 for analytical studies that reported an adjusted effect estimate of the association between PPI use and CDI. We performed random-effect meta-analyses. We used the GRADE framework to interpret the findings. RESULTS: We identified 47 eligible citations (37 case-control and 14 cohort studies with corresponding 51 effect estimates. The pooled OR was 1.65, 95% CI (1.47, 1.85, I(2 = 89.9%, with evidence of publication bias suggested by a contour funnel plot. A novel regression based method was used to adjust for publication bias and resulted in an adjusted pooled OR of 1.51 (95% CI, 1.26-1.83. In a speculative analysis that assumes that this association is based on causality, and based on published baseline CDI incidence, the risk of CDI would be very low in the general population taking PPIs with an estimated NNH of 3925 at 1 year. CONCLUSIONS: In this rigorously conducted systemic review and meta-analysis, we found very low quality evidence (GRADE class for an association between PPI use and CDI that does not support a cause-effect relationship.

  18. [Evaluation of an original tool for carbohydrate counting, aimed at facilitating the implementation of functional insulin therapy].

    Science.gov (United States)

    Reach, Gérard; Choleau, Carine

    2013-01-01

    Carbohydrate counting is the most difficult component of functional insulin therapy. We thus designed a tool to facilitate carbohydrate counting of meals. The tool consists of an illustrated directory (16 x 10 cm, 119 pages) presenting 389 pictures of food, classified in 12 categories (breads, fruits, vegetables, etc.). For each photo, the name and mode of preparation of the foods are given, with the weight of the illustrated portion and its carbohydrate content as a multiple of 5 g. During the first phase of the study (3 days a week for 12 weeks), twelve patients with type 1 diabetes completed a precise food diary using a list and weight of all consumed foods. We were thus able to determine, for each of three meals (breakfast, lunch and dinner), the variability of their carbohydrate content. During the second phase of the study (2 weeks), the patients were given the possibility of using the illustrated food directory. We asked them first to estimate, from the photos, the global carbohydrate content of their meals, and then to weigh each food. This allowed us to calculate the true carbohydrate content of the meals from nutritional tables. During the first phase, the carbohydrate contents of breakfast, lunch and dinner were 67 +/- 29, 72 +/- 30 and 74 +/- 30 g, respectively (mean +/- SD, n = 12). For a given patient, the variability in the carbohydrate content of each meal was expressed by its standard deviation (SD). For the 12 patients, this variability was 18+/-+ 8, 25+/-+ 8 and 27+/-+ 11 g, respectively, for breakfast, lunch and dinner, and represented on the average about one-quarter of the total carbohydrate content. During the second phase, carbohydrate content, estimated by the patients using the illustrated food directory, correlated well with the retrospective evaluation based on nutritional tables (y = 0.95 x + 5 g, r2 = 0.8 ; n = 12, 235 meals). This new illustrated food repertory allows accurate evaluation of the highly variable carbohydrate content of

  19. Effects of preoperative aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in patients undergoing off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan

    2007-07-01

    Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.

  20. High-Protein Intake during Weight Loss Therapy Eliminates the Weight-Loss-Induced Improvement in Insulin Action in Obese Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    Gordon I. Smith

    2016-10-01

    Full Text Available High-protein (HP intake during weight loss (WL therapy is often recommended because it reduces the loss of lean tissue mass. However, HP intake could have adverse effects on metabolic function, because protein ingestion reduces postprandial insulin sensitivity. In this study, we compared the effects of ∼10% WL with a hypocaloric diet containing 0.8 g protein/kg/day and a hypocaloric diet containing 1.2 g protein/kg/day on muscle insulin action in postmenopausal women with obesity. We found that HP intake reduced the WL-induced decline in lean tissue mass by ∼45%. However, HP intake also prevented the WL-induced improvements in muscle insulin signaling and insulin-stimulated glucose uptake, as well as the WL-induced adaptations in oxidative stress and cell structural biology pathways. Our data demonstrate that the protein content of a WL diet can have profound effects on metabolic function and underscore the importance of considering dietary macronutrient composition during WL therapy for people with obesity.

  1. Insulin receptors

    International Nuclear Information System (INIS)

    Kahn, C.R.; Harrison, L.C.

    1988-01-01

    This book contains the proceedings on insulin receptors. Part A: Methods for the study of structure and function. Topics covered include: Method for purification and labeling of insulin receptors, the insulin receptor kinase, and insulin receptors on special tissues

  2. Knowledge Translation to Optimize Adult Inpatient Glycemic Management with Basal Bolus Insulin Therapy and Improve Patient Outcomes.

    Science.gov (United States)

    Helmle, Karmon E; Chacko, Sunita; Chan, Trevor; Drake, Alison; Edwards, Alun L; Moore, Glenda E; Philp, Leta C; Popeski, Naomi; Roedler, Rhonda L; Rogers, Edwin J R; Zimmermann, Gabrielle L; McKeen, Julie

    2017-12-27

    To develop and evaluate a Basal Bolus Insulin Therapy (BBIT) Knowledge Translation toolkit to address barriers to adoption of established best practice with BBIT in the care of adult inpatients. This study was conducted in 2 phases and focused on the hospitalist provider group across 4 acute care facilities in Calgary. Phase 1 involved a qualitative evaluation of provider and site specific barriers and facilitators, which were mapped to validated interventions using behaviour change theory. This informed the co-development and optimization of the BBIT Knowledge Translation toolkit, with each tool targeting a specific barrier to improved diabetes care practice, including BBIT ordering. In Phase 2, the BBIT Knowledge Translation toolkit was implemented and evaluated, focusing on BBIT ordering frequency, as well as secondary outcomes of hyperglycemia (patient-days with BG >14.0 mmol/L), hypoglycemia (patient-days with BG Knowledge Translation toolkit resulted in a significant 13% absolute increase in BBIT ordering. Hyperglycemic patient-days were significantly reduced, with no increase in hypoglycemia. There was a significant, absolute 14% reduction in length of stay. The implementation of an evidence-informed, multifaceted BBIT Knowledge Translation toolkit effectively reduced a deeply entrenched in-patient diabetes care gap. The resulting sustained practice change improved patient clinical and system resource utilization outcomes. This systemic approach to implementation will guide further scale and spread of glycemic optimization initiatives. Copyright © 2018 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  3. The effect of CPAP therapy on insulin-like growth factor and cognitive functions in obstructive sleep apnea patients.

    Science.gov (United States)

    Kanbay, Asiye; Demir, Neslihan Cerrah; Tutar, Nuri; Köstek, Osman; Özer Şimşek, Zuhal; Buyukoglan, Hakan; Demir, Ramazan; Parrino, Liborio

    2017-07-01

    Cognitive impairment is common among patients with obstructive sleep apnea syndrome (OSAS). In this study, we aimed to investigate the effect of continuous positive airway pressure (CPAP) therapy on serum insulin-like growth factor-1 (IGF-1) levels and cognitive functions in patients with OSAS. Thirty-three patients with newly diagnosed OSAS and 17 healthy-control subjects enrolled in the study. All individuals completed the mini-mental state examination (MMSE) to evaluate cognitive function. Blood samples were taken at the end of the polysomnography in the morning and the same procedures were repeated 3 months after starting CPAP treatment. In the OSAS group, the baseline MMSE score was 23.5 ± 3.6, and serum IGF-1 level was 79.1 ± 36.1 ng/mL. Both values were significantly lower compared with the control group (mean MMSE score = 28.1 ± 1.4, P = 0.0001; mean serum IGF-1 level = 147.1 ± 49.1 ng/mL, P < 0.0001). Three months after CPAP treatment, OSAS patients showed a significant improvement in MMSE scores (26.5 ± 2.8, P = 0.0001) and serum IGF-1 level (129.1 ± 58.2, P = 0.0001). In contrast, baseline and third-month measurements for IGF-1 levels and MMSE scores were not significantly different in the control group. The results indicate that effective CPAP therapy in OSAS patients leads to significant improvement in cognitive functions and IGF-1 even in a short-term follow-up. Cognitive function assessment might be a part of evaluation in OSAS patients. © 2015 John Wiley & Sons Ltd.

  4. [News and perspectives in insulin treatment].

    Science.gov (United States)

    Haluzík, Martin

    2014-09-01

    Insulin therapy is a therapeutic cornerstone in patients with type 1 diabetes and also in numerous patients with type 2 diabetes especially with longer history of diabetes. The initiation of insulin therapy in type 2 diabetes patients is often delayed which is at least partially due to suboptimal pharmacokinetic characteristics of available insulins. The development of novel insulins with more favorable characteristics than those of current insulins is therefore still ongoing. The aim of this paper is to review current knowledge of novel insulins that have been recently introduced to the market or are getting close to routine clinical use. We will also focus on the perspectives of insulin therapy in the long-term run including the alternative routes of insulin administration beyond its classical subcutaneous injection treatment.Key words: alternative routes of insulin administration - diabetes mellitus - hypoglycemia - insulin - insulin analogues.

  5. Continuation versus discontinuation of insulin secretagogues when initiating insulin in type 2 diabetes

    NARCIS (Netherlands)

    Swinnen, S. G.; Dain, M.-P.; Mauricio, D.; DeVries, J. H.; Hoekstra, J. B.; Holleman, F.

    2010-01-01

    We compared the combined use of basal insulin, metformin and insulin secretagogues with a combination of basal insulin and metformin in patients with type 2 diabetes starting basal insulin analogue therapy. This analysis was part of a 24-week trial, in which 964 insulin-naive patients with type 2

  6. A Combined Therapy with Myo-Inositol and D-Chiro-Inositol Improves Endocrine Parameters and Insulin Resistance in PCOS Young Overweight Women

    Directory of Open Access Journals (Sweden)

    Elena Benelli

    2016-01-01

    Full Text Available Introduction. We evaluated the effects of a therapy that combines myo-inositol (MI and D-chiro-inositol (DCI in young overweight women affected by polycystic ovary syndrome (PCOS, characterized by oligo- or anovulation and hyperandrogenism, correlated to insulin resistance. Methods. We enrolled 46 patients affected by PCOS and, randomly, we assigned them to two groups, A and B, treated, respectively, with the association of MI plus DCI, in a 40 : 1 ratio, or with placebo (folic acid for six months. Thus, we analyzed pretreatment and posttreatment FSH, LH, 17-beta-Estradiol, Sex Hormone Binding Globulin, androstenedione, free testosterone, dehydroepiandrosterone sulphate, HOMA index, and fasting glucose and insulin. Results. We recorded a statistically significant reduction of LH, free testosterone, fasting insulin, and HOMA index only in the group treated with the combined therapy of MI plus DCI; in the same patients, we observed a statistically significant increase of 17-beta-Estradiol levels. Conclusions. The combined therapy of MI plus DCI is effective in improving endocrine and metabolic parameters in young obese PCOS affected women.

  7. Insulin structure and stability.

    Science.gov (United States)

    Brange, J; Langkjoer, L

    1993-01-01

    Insulin is composed of 51 amino acids in two peptide chains (A and B) linked by two disulfide bonds. The three-dimensional structure of the insulin molecule (insulin monomer), essentially the same in solution and in solid phase, exists in two main conformations. These differ in the extent of helix in the B chain which is governed by the presence of phenol or its derivatives. In acid and neutral solutions, in concentrations relevant for pharmaceutical formulation, the insulin monomer assembles to dimers and at neutral pH, in the presence of zinc ions, further to hexamers. Many crystalline modifications of insulin have been identified but only those with the hexamer as the basic unit are utilized in preparations for therapy. The insulin hexamer forms a relatively stable unit but some flexibility remains within the individual molecules. The intrinsic flexibility at the ends of the B chain plays an important role in governing the physical and chemical stability of insulin. A variety of chemical changes of the primary structure (yielding insulin derivatives), and physical modifications of the secondary to quaternary structures (resulting in "denaturation," aggregation, and precipitation) are known to affect insulin and insulin preparations during storage and use (Fig. 8). The tendency of insulin to undergo structural transformation resulting in aggregation and formation of insoluble insulin fibrils has been one of the most intriguing and widely studied phenomena in relation to insulin stability. Although the exact mechanism of fibril formation is still obscure, it is now clear that the initial step is an exposure of certain hydrophobic residues, normally buried in the three-dimensional structure, to the surface of the insulin monomer. This requires displacement of the COOH-terminal B-chain residues from their normal position which can only be accomplished via monomerization of the insulin. Therefore, most methods stabilizing insulin against fibrillation share the

  8. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature.

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-08-15

    to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de

  9. Insulin provision therapy and mortality in older adults with diabetes mellitus and stable ischemic heart disease: Insights from BARI-2D trial.

    Science.gov (United States)

    Damluji, Abdulla A; Cohen, Erin R; Moscucci, Mauro; Myerburg, Robert J; Cohen, Mauricio G; Brooks, Maria M; Rich, Michael W; Forman, Daniel E

    2017-08-15

    Optimal strategies for glucose control in very old adults with diabetes and stable ischemic heart disease (SIHD) are unclear. To compare the effects of insulin provision (IP) therapy versus insulin sensitizing (IS) therapy for glycemic control in older (≥75years) and younger (type II diabetes (DM) and SIHD. Adults enrolled in the Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) were studied. The BARI 2D study population (all with type II DM and SIHD) was randomized twice: (1) between revascularization plus intensive medical therapy versus intensive medical therapy alone, and (2) between IP versus IS therapies. The primary endpoint was all-cause-mortality over five-year follow-up. In this substudy outcomes related to IP vs. IS are assessed in relation to age. Adults aged ≥75years who received IP versus IS are compared to those 182 (8%) were ≥75years. Compared to younger subjects, the older cohort had lower BMI, higher diuretic use, worse kidney function, and increased history of heart failure. Within the older cohort, the IP and IS subgroups were similar in respect to baseline cardiovascular risk factors, medications, and coronary artery disease severity. During follow-up, the older subjects receiving IP therapy had higher cardiovascular mortality compared to those receiving IS therapy (16% vs. 11%, p=0.040). Using Cox proportional hazards analysis, the older IP subjects were at increased risk for all-cause-mortality (hazard ratio 1.89, CI 1.1-3.2, p=0.020). No mortality difference between IP and IS was observed in those diabetes and SIHD aged ≥75years, IP therapy may be associated with increased mortality compared to IS therapy. Additional studies are needed to further refine optimal treatment strategies for diabetes and SIHD in old age. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  10. The Effect of Metformin and Standard Therapy Versus Standard Therapy Alone in Nondiabetic Patients with Insulin Resistance and Nonalcoholic Steatohepatitis (NASH): A Pilot Trial

    Science.gov (United States)

    2009-01-01

    histology in nondiabetic patients with insulin resistance and NASH. Decrease in BMI through diet and exercise significantly improved HOMA - IR scores, serum...BMI through diet and exercise significantly improved HOMA - IR scores, serum aminotransferases and liver histology. 15. SUBJECT TERMS 16. SECURITY...insulin resistance (or HOMA - IR ) score was calculated using the formula: fasting insulin (mIU/ml) fasting glu- cose (mg/dl)/405 [Matthews et al. 1985

  11. Algorithmic approach to patients presenting with heartburn and epigastric pain refractory to empiric proton pump inhibitor therapy.

    Science.gov (United States)

    Roorda, Andrew K; Marcus, Samuel N; Triadafilopoulos, George

    2011-10-01

    Reflux-like dyspepsia (RLD), where predominant epigastric pain is associated with heartburn and/or regurgitation, is a common clinical syndrome in both primary and specialty care. Because symptom frequency and severity vary, overlap among gastroesophageal reflux disease (GERD), non-erosive reflux disease (NERD), and RLD, is quite common. The chronic and recurrent nature of RLD and its variable response to proton pump inhibitor (PPI) therapy remain problematic. To examine the prevalence of GERD, NERD, and RLD in a community setting using an algorithmic approach and to assess the potential, reproducibility, and validity of a multi-factorial scoring system in discriminating patients with RLD from those with GERD or NERD. Using a novel algorithmic approach, we evaluated an outpatient, community-based cohort referred to a gastroenterologist because of epigastric pain and heartburn that were only partially relieved by PPI. After an initial symptom evaluation (for epigastric pain, heartburn, regurgitation, dysphagia), an endoscopy and distal esophageal biopsies were performed, followed by esophageal motility and 24-h ambulatory pH monitoring to assess esophageal function and pathological acid exposure. A scoring system based on presence of symptoms and severity of findings was devised. Data was collected in two stages: subjects in the first stage were designated as the derivation cohort; subjects in the second stage were labeled the validation cohort. The total cohort comprised 159 patients (59 males, 100 females; mean age 52). On endoscopy, 30 patients (19%) had complicated esophagitis (CE) and 11 (7%) had Barrett's esophagus (BE) and were classified collectively as patients with GERD. One-hundred and eighteen (74%) patients had normal esophagus. Of these, 94 (59%) had one or more of the following: hiatal hernia, positive biopsy, abnormal pH, and/or abnormal motility studies and were classified as patients with NERD. The remaining 24 patients (15%) had normal functional

  12. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  13. Basal-bolus insulin therapy reduces maternal triglycerides in gestational diabetes without modifying cholesteryl ester transfer protein activity.

    Science.gov (United States)

    Olmos, Pablo R; Borzone, Gisella R

    2017-09-01

    Macrosomia in the offspring of overweight/obese mothers with glucose-controlled gestational diabetes mellitus (GDM) is due to excessive rise of maternal triglycerides (TG). We aimed to ascertain whether basal-bolus insulin therapy (BBIT), or other components of the treatment, could reduce TG in GDM. We studied the records of 131 singleton pregnancies with GDM, using stepwise multiple linear regression, Mann-Whitney, χ 2 , and Jonckheere-Terpstra tests. As maternal TG increased steadily during normal pregnancy, these were transformed as z-scores. The atherogenic index of plasma (AIP) was calculated as a measure of cholesteryl ester transfer protein activity. Multiple regression showed that only BBIT (but neither limitation of weight gain nor metformin) reduced maternal TG z-scores (P = 0.011). When the 131 pregnancies were split into two groups - without BBIT (n = 58; HbA1c = 5.3 ± 0.3%) and with BBIT (n = 73; HbA1c = 5.4 ± 0.6; P = 0.2005) - we observed that BBIT (n = 73) reduced maternal TG z-scores in a dose-related fashion (Jonckheere-Terpstra P = 0.03817). The atherogenic index of plasma remained within normal range in both groups. BBIT (but not weight gain control nor metformin) reduced maternal TG in mothers with glucose-controlled GDM. This beneficial effect of BBIT was not related to changes in the cholesteryl ester transfer protein activity. © 2017 Japan Society of Obstetrics and Gynecology.

  14. Phenolic excipients of insulin formulations induce cell death, pro-inflammatory signaling and MCP-1 release

    Directory of Open Access Journals (Sweden)

    Claudia Weber

    2015-01-01

    Insulin solutions displayed cytotoxic and pro-inflammatory potential caused by phenol or m-cresol. We speculate that during insulin pump therapy phenol and m-cresol might induce cell death and inflammatory reactions at the infusion site in vivo. Inflammation is perpetuated by release of MCP-1 by activated monocytic cells leading to enhanced recruitment of inflammatory cells. To minimize acute skin complications caused by phenol/m-cresol accumulation, a frequent change of infusion sets and rotation of the infusion site is recommended.

  15. Short-acting glucagon-like peptide-1 receptor agonists as add-on to insulin therapy in type 1 diabetes

    DEFF Research Database (Denmark)

    Albèr, Anders; Brønden, Andreas; Knop, Filip K

    2017-01-01

    emptying in patients with type 1 diabetes, which could translate into effective lowering of postprandial glucose excursions; however, these observations regarding short-acting GLP-1RAs are all derived from small open-label trials and should thus be interpreted with caution. In the present paper we review......A large proportion of patients with type 1 diabetes do not reach their glycaemic target of glycated hemoglobin (HbA1c) type 1 diabetes are overweight and obese. Treatment of type 1 diabetes is based on insulin therapy......, which is associated with well-described and unfortunate adverse effects such as hypoglycaemia and increased body weight. Glucagon-like peptide-1 (GLP-1) receptor agonists (RAs) are the focus of increasing interest as a possible adjunctive treatment to insulin in type 1 diabetes because...

  16. [The myo-inositol is beneficial in the therapy of pregnancy with insulin-dependent type 2 diabetes and polycystic ovary syndrome].

    Science.gov (United States)

    Kun, Attila; Tornóczky, János

    2017-04-01

    Authors would like to demonstrate the beneficial effect of myo-inositol supplementation in a pregnant woman with insulin-dependent type 2 diabetes mellitus and polycystic ovary syndrome. Insulin and metformin treatment could not achieve normalization of glucose homeostasis for 3 years, and hypoglycemic episodes were frequent. Myo-inositol and folic acid supplementation added to the basic treatment resulted in improved glucose levels in 2 months. At this time she became pregnant. During pregnancy serum glucose levels still improved in the next 2 months. The amniotic membrane ruptured at the 19th gestational week, and pregnancy had to be finished. Developmental disturbances were excluded by the pathologist. She became pregnant again and gave birth to a premature male neonate at the 29th gestational week. The aim of the report was to demonstrate that myo-inositol supplementation may improve the efficacy of the therapy in type 2 diabetes mellitus. Orv. Hetil., 2017, 158(14), 541-545.

  17. Proton pump inhibitor co-prescription with dual antiplatelet therapy among patients with acute coronary syndrome in Qatar.

    Science.gov (United States)

    Awaisu, Ahmed; Hamou, Fatima; Mekideche, Lylia; El Muabby, Nisrine; Mahfouz, Ahmed; Mohammed, Shaban; Saad, Ahmad

    2016-04-01

    There are increasing concerns about clinically significant interactions between proton pump inhibitors (PPIs) and clopidogrel, resulting in adverse cardiovascular outcomes in patients with acute coronary syndromes (ACS). However, published evidence on the prevalence and predictors of PPI use with dual antiplatelet therapy (DAPT) is scarce. This study investigated the prevalence of PPI use among patients with ACS receiving DAPT and possible predictors of co-prescribing the PPIs with the DAPT. Heart Hospital, a specialized tertiary care center in Qatar. A retrospective observational study of a prescription database was conducted. Subjects included 626 patients admitted between January and December 2012 with the diagnosis of ACS who received DAPT and discharged with or without a PPI. Univariate analysis and multivariate binary logistic regression analysis were performed to determine the predictors of PPI-DAPT co-prescription. Prevalence of PPI co-prescribing with DAPT in proportions and percentages and odd ratios for the predictors of PPI-DAPT co-prescribing. A total of 626 patients were analyzed for PPI prevalence, with 200 patients (32 %) being prescribed PPI with DAPT upon discharge. After controlling for confounders, PPI use on admission (aOR 14.5; 95 % CI 7.6-27.6, p < 0.001), nationality (aOR 3.2; 95 % CI 1.1-9.9, p = 0.041), and having a history of diabetes (aOR 0.5; 95 % CI 0.24-0.99, p = 0.046) significantly influenced PPI-DAPT co-prescribing. Users of PPI on admission compared to nonusers were about 15 times more likely to be prescribed PPI with DAPT upon discharge; likewise, having Qatari nationality increased the likelihood of co-prescribing PPI with DAPT upon discharge by three folds. Lastly, patients with a history of diabetes were 50 % less likely to be prescribed PPIs upon discharge compared to those with no history of diabetes. The rate of PPI co-prescribing with DAPT in the population studied was relatively high. The strongest predictor of PPI co

  18. Symptoms of depression and diabetes-specific emotional distress are associated with a negative appraisal of insulin therapy in insulin-naïve patients with Type 2 diabetes mellitus. A study from the European Depression in Diabetes [EDID] Research Consortium

    DEFF Research Database (Denmark)

    Makine, Ceylan; Karşidağ, C; Kadioğlu, P

    2009-01-01

    AIMS: A meta-analysis concluded that depression is associated with poor glycaemic control in Type 2 diabetes (DM2). In DM2 patients with deteriorating glycaemic control, the initiation of insulin therapy is often postponed. The aim of the present study was to determine whether symptoms of depress......AIMS: A meta-analysis concluded that depression is associated with poor glycaemic control in Type 2 diabetes (DM2). In DM2 patients with deteriorating glycaemic control, the initiation of insulin therapy is often postponed. The aim of the present study was to determine whether symptoms...... of depression and diabetes-specific emotional distress are associated with a more negative appraisal of insulin therapy. METHODS: We collected cross-sectional data in two outpatient university clinics in Istanbul, Turkey. The study sample consisted of 154 insulin-naïve patients with DM2. A self...... scores. Multiple regression analyses showed that a negative appraisal of insulin therapy was significantly associated with higher depression and diabetes-distress scores and low education, but not with sex, age or duration of diabetes. CONCLUSIONS: Our results suggest that in insulin-naïve Type 2...

  19. Supervised Exercise Training Counterbalances the Adverse Effects of Insulin Therapy in Overweight/Obese Subjects With Type 2 Diabetes

    OpenAIRE

    Balducci, Stefano; Zanuso, Silvano; Cardelli, Patrizia; Salerno, Gerardo; Fallucca, Sara; Nicolucci, Antonio; Pugliese, Giuseppe

    2011-01-01

    OBJECTIVE To examine the effect of supervised exercise on traditional and nontraditional cardiovascular risk factors in sedentary, overweight/obese insulin-treated subjects with type 2 diabetes from the Italian Diabetes Exercise Study (IDES). RESEARCH DESIGN AND METHODS The study randomized 73 insulin-treated patients to twice weekly supervised aerobic and resistance training plus structured exercise counseling (EXE) or to counseling alone (CON) for 12 months. Clinical and laboratory paramete...

  20. Cost-effectiveness of liraglutide versus lixisenatide as add-on therapies to basal insulin in type 2 diabetes.

    Science.gov (United States)

    Ericsson, Åsa; Glah, Divina; Lorenzi, Maria; Jansen, Jeroen P; Fridhammar, Adam

    2018-01-01

    We assessed the cost-effectiveness of the glucagon-like peptide 1 receptor agonists liraglutide 1.8 mg and lixisenatide 20 μg (both added to basal insulin) in patients with type 2 diabetes (T2D) in Sweden. The Swedish Institute for Health Economics cohort model for T2D was used to compare liraglutide and lixisenatide (both added to basal insulin), with a societal perspective and with comparative treatment effects derived by indirect treatment comparison (ITC). Drug prices were 2016 values, and all other costs 2015 values. The cost-effectiveness of IDegLira (fixed-ratio combination of insulin degludec and liraglutide) versus lixisenatide plus basal insulin was also assessed, under different sets of assumptions. From the ITC, decreases in HbA1c were -1.32% and -0.43% with liraglutide and lixisenatide, respectively; decreases in BMI were -1.29 and -0.65 kg/m2, respectively. An estimated 2348 cases of retinopathy, 265 of neuropathy and 991 of nephropathy would be avoided with liraglutide compared with lixisenatide in a cohort of 10,000 patients aged over 40 years. In the base-case analysis, total direct costs were higher with liraglutide than lixisenatide, but costs associated with complications were lower. The cost/quality-adjusted life-year (QALY) for liraglutide added to basal insulin was SEK30,802. Base-case findings were robust in sensitivity analyses, except when glycated haemoglobin (HbA1c) differences for liraglutide added to basal insulin were abolished, suggesting these benefits were driving the cost/QALY. With liraglutide 1.2 mg instead of liraglutide 1.8 mg (adjusted for efficacy and cost), liraglutide added to basal insulin was dominant over lixisenatide 20μg.IDegLira was dominant versus lixisenatide plus basal insulin when a defined daily dose was used in the model. The costs/QALY for liraglutide, 1.8 or 1.2 mg, added to basal insulin, and for IDegLira (all compared with lixisenatide 20 μg added to basal insulin) were below the threshold considered low

  1. Cost-effectiveness of liraglutide versus lixisenatide as add-on therapies to basal insulin in type 2 diabetes

    Science.gov (United States)

    2018-01-01

    Background We assessed the cost-effectiveness of the glucagon-like peptide 1 receptor agonists liraglutide 1.8 mg and lixisenatide 20 μg (both added to basal insulin) in patients with type 2 diabetes (T2D) in Sweden. Methods The Swedish Institute for Health Economics cohort model for T2D was used to compare liraglutide and lixisenatide (both added to basal insulin), with a societal perspective and with comparative treatment effects derived by indirect treatment comparison (ITC). Drug prices were 2016 values, and all other costs 2015 values. The cost-effectiveness of IDegLira (fixed-ratio combination of insulin degludec and liraglutide) versus lixisenatide plus basal insulin was also assessed, under different sets of assumptions. Results From the ITC, decreases in HbA1c were –1.32% and –0.43% with liraglutide and lixisenatide, respectively; decreases in BMI were –1.29 and –0.65 kg/m2, respectively. An estimated 2348 cases of retinopathy, 265 of neuropathy and 991 of nephropathy would be avoided with liraglutide compared with lixisenatide in a cohort of 10,000 patients aged over 40 years. In the base-case analysis, total direct costs were higher with liraglutide than lixisenatide, but costs associated with complications were lower. The cost/quality-adjusted life-year (QALY) for liraglutide added to basal insulin was SEK30,802. Base-case findings were robust in sensitivity analyses, except when glycated haemoglobin (HbA1c) differences for liraglutide added to basal insulin were abolished, suggesting these benefits were driving the cost/QALY. With liraglutide 1.2 mg instead of liraglutide 1.8 mg (adjusted for efficacy and cost), liraglutide added to basal insulin was dominant over lixisenatide 20μg.IDegLira was dominant versus lixisenatide plus basal insulin when a defined daily dose was used in the model. Conclusions The costs/QALY for liraglutide, 1.8 or 1.2 mg, added to basal insulin, and for IDegLira (all compared with lixisenatide 20 μg added to basal

  2. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  3. Continuous intraperitoneal insulin infusion in the treatment of type 1 diabetes mellitus: Glycaemia and beyond

    OpenAIRE

    van Dijk, Peter R.

    2015-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a last-resort treatment option for selected patients with type 1 diabetes mellitus (T1DM). As compared to the most commonly used forms of insulin administration -injections and an externally placed pump- which deliver insulin in the subcutaneous (SC) tissue, CIPII delivers the insulin in the intraperitoneal space. CIPII using an implantable pump is an unique treatment which has been available for more than 30 year...

  4. Omega-3 fatty acid therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation, however, did not significantly improve insulin sensitivity in patients with hypertriglyceridemia.

    Science.gov (United States)

    Oh, Pyung Chun; Koh, Kwang Kon; Sakuma, Ichiro; Lim, Soo; Lee, Yonghee; Lee, Seungik; Lee, Kyounghoon; Han, Seung Hwan; Shin, Eak Kyun

    2014-10-20

    Experimental studies demonstrate that higher intake of omega-3 fatty acids (n-3 FA) improves insulin sensitivity, however, we reported that n-3 FA 2g therapy, most commonly used dosage did not significantly improve insulin sensitivity despite reducing triglycerides by 21% in patients. Therefore, we investigated the effects of different dosages of n-3 FA in patients with hypertriglyceridemia. This was a randomized, single-blind, placebo-controlled, parallel study. Age, sex, and body mass index were matched among groups. All patients were recommended to maintain a low fat diet. Forty-four patients (about 18 had metabolic syndrome/type 2 diabetes mellitus) in each group were given placebo, n-3 FA 1 (O1), 2 (O2), or 4 g (O4), respectively daily for 2 months. n-3 FA therapy dose-dependently and significantly decreased triglycerides and triglycerides/HDL cholesterol and improved flow-mediated dilation, compared with placebo (by ANOVA). However, each n-3 FA therapy did not significantly decrease high-sensitivity C-reactive protein and fibrinogen, compared with placebo. O1 significantly increased insulin levels and decreased insulin sensitivity (determined by QUICKI) and O2 significantly decreased plasma adiponectin levels relative to baseline measurements. Of note, when compared with placebo, each n-3 FA therapy did not significantly change insulin, glucose, adiponectin, glycated hemoglobin levels and insulin sensitivity (by ANOVA). We observed similar results in a subgroup of patients with the metabolic syndrome. n-3 FA therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation. Nonetheless, n-3 FA therapy did not significantly improve acute-phase reactants and insulin sensitivity in patients with hypertriglyceridemia, regardless of dosages. Copyright © 2014. Published by Elsevier Ireland Ltd.

  5. The efficacy of pharmaceutical combination of glucose, insulin, potassium, and magnesium along with thrombolytic therapy on the mortality of patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Mohammad Garakyaraghi

    2012-03-01

    Full Text Available BACKGROUND: Despite conventional treatment methods of acute myocardial infarction, its complications and mortality rates are still very high. Finding new cost-effective treatments like regulation of ischemic muscle metabolism at the time of thrombolytic therapy can meet this requirement to some extent. This study investigated the efficacy of the pharmaceutical combination of glucose, insulin, potassium (GIK and magnesium along with thrombolytic therapy.METHODS: In a double-blind, controlled clinical trial, 200 patients with acute myocardial infarction who had the indication for thrombolytic treatment were selected and divided to 6 groups of almost 30 people. A specific treatment protocol was designed for each group. The patients in the first 5 groups were compared with the ones in the sixth group as the control group in terms of frequency of complications and in-hospital mortality and also mortality during 3 and 6 months after the treatment.RESULTS: Mean age of the patients was 58.77 ± 2.6 years. Males constituted 77% of the study population. Heart failure, in-hospital arrhythmia and ejection fraction (EF at discharge showed favorable results in the five groups which received metabolic regulations as compared to the control group. In-hospital mortality of no groups was different from that of the control group (P > 0.05. Three months after the treatment, mortality of the group that received GIK and magnesium was lower than that of the control group (P < 0.05. After 6 months, none of the patients who received high-dose GIK and magnesium along with thrombolytic therapy died while the mortality rate of the control group was 44.4% (P < 0.05.CONCLUSION: The infusion of GIK and magnesium solution along with thrombolytic therapy can lead to a decrease in the long-term mortality and complications in patients with acute myocardial infarction.Keywords: Acute Myocardial Infarction, Glucose, Insulin, Potassium, Magnesium, Thrombolytic Therapy

  6. Effect of Acarbose, Sitagliptin and combination therapy on blood glucose, insulin, and incretin hormone concentrations in experimentally induced postprandial hyperglycemia of healthy cats.

    Science.gov (United States)

    Mori, Akihiro; Ueda, Kaori; Lee, Peter; Oda, Hitomi; Ishioka, Katsumi; Arai, Toshiro; Sako, Toshinori

    2016-06-01

    Acarbose (AC) and Sitagliptin (STGP) are oral hypoglycemic agents currently used either alone or in conjunction with human diabetic (Type 2) patients. AC has been used with diabetic cats, but not STGP thus far. Therefore, the objective of this study was to determine the potential use of AC or STGP alone and in combination for diabetic cats, by observing their effect on short-term post-prandial serum glucose, insulin, and incretin hormone (active glucagon-like peptide-1 (GLP-1) and total glucose dependent insulinotropic polypeptide (GIP)) concentrations in five healthy cats, following ingestion of a meal with maltose. All treatments tended (pglucose area under the curve (AUC), with an accompanying significant reduction (pAUC as compared to no treatment. Meanwhile, a significant increase (pAUC was observed with STGP (100% higher) and combined treatment (130% greater), as compared to either AC or no treatment. Lastly, a significant reduction (pAUC was observed with STGP (21% reduction) and combined treatment (7% reduction) as compared to control. Overall, AC, STGP, or combined treatment can significantly induce positive post-prandial changes to insulin and incretin hormone levels of healthy cats. Increasing active GLP-1 and reducing postprandial hyperglycemia appear to be the principal mechanisms of combined treatment. Considering the different, but complementary mechanisms of action by which AC and STGP induce lower glucose and insulin levels, combination therapy with both these agents offers great potential for treating diabetic cats in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Increased prandial air swallowing and postprandial gas-liquid reflux among patients refractory to proton pump inhibitor therapy

    NARCIS (Netherlands)

    Bravi, Ivana; Woodland, Philip; Gill, Ravinder S.; Al-Zinaty, Mohannad; Bredenoord, Albert J.; Sifrim, Daniel

    2013-01-01

    Many patients with gastroesophageal reflux disease (GERD) have persistent reflux despite treatment with proton pump inhibitors (PPIs). Mixed gas-liquid reflux events are more likely to be perceived as symptomatic. We used esophageal impedance monitoring to investigate whether esophageal gas is

  8. Progression to insulin for patients with diabetes mellitus on dual oral antidiabetic therapy using the US Department of Defense Database.

    Science.gov (United States)

    Rascati, K; Richards, K; Lopez, D; Cheng, L-I; Wilson, J

    2013-10-01

    To compare 'progression to insulin' for three cohorts on oral antidiabetic medication combinations: metformin/sulphonylurea (Met/SU), metformin/thiazolidinedione (Met/TZD) and sulphonylurea/thiazolidinedione (SU/TZD). Retrospective cohort analysis design was used. The subjects were US nationwide members of military and their families. A total of 5608 patients who were on antidiabetic monotherapy for at least 1 year before adding a second agent to their medication regimen between October 2001 and September 2008 participated in this study. Mean age ranged from 64 to 71 years among the cohorts. Cox regression compared the progression to insulin, adjusting for demographics, months of follow-up and co-morbidities [measured with Chronic Disease Score (CDS)]. By the end of the 2- to 6-year follow-up period, 14.3% of the Met/TZD cohort, 23.6% of the Met/SU cohort and 28.2% of the SU/TZD cohort had insulin added to their regimen. Those in the Met/SU cohort had a 1.8 times higher probability of progression to insulin than those in the Met/TZD cohort [odds ratio (OR) = 1.80, 95% confidence interval (CI) = 1.51-2.14), and those in the SU/TZD cohort had a 2.5 times higher probability of progression to insulin than those in the Met/TZD cohort (OR = 2.51, 95% CI = 2.04-3.08). When sensitizers were paired (Met/TZD), a lower percentage of patients progressed to insulin during the study period, as opposed to patients who used a combination of a secretagogue with a sensitizer (SU/TZD or Met/SU). © 2013 John Wiley & Sons Ltd.

  9. Renal function preservation with pioglitazone or with basal insulin as an add-on therapy for patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Chang, Yu-Hung; Hwu, Der-Wei; Chang, Dao-Ming; An, Ling-Wang; Hsieh, Chang-Hsun; Lee, Yau-Jiunn

    2017-06-01

    Clinical outcome may differ owing to the distinct pharmacological characteristics of insulin sensitizers and insulin. This study was performed to compare the metabolic and renal function changes with add-on pioglitazone treatment versus basal insulin in patients with type 2 diabetes mellitus (DM) in whom sulfonylurea and metformin regimens failed. Patients who were consecutively managed in the diabetes comprehensive program with add-on pioglitazone or detemir/glargine treatment for at least 2 years following sulfonylurea and metformin treatment failure were included. A total of 1002 patients were enrolled (pioglitazone: 559, detemir: 264, glargine: 179). After propensity score matching, there were 105 patients with matchable baseline characteristics in each group. After a mean of 3.5 years of follow-up, the pioglitazone group showed a greater HbA1c reduction than the detemir group and the glargine group. Despite patients in all three groups exhibiting significant body weight gain, those in the pioglitazone group and the glargine group showed greater body weight increases than the patients in the detemir group (2.1, 1.6 and 0.8 kg, respectively, p 1.79-3.88) and 3.13 (95% CI 2.01-4.87), respectively. Our study first showed that treatment with both pioglitazone and basal insulin improved glycemic control, while only pioglitazone treatment was observed to be advantageous in terms of preserving renal function when used as an add-on therapy for patients with type 2 DM in whom sulfonylurea and metformin regimens failed.

  10. IDegLira Versus Alternative Intensification Strategies in Patients with Type 2 Diabetes Inadequately Controlled on Basal Insulin Therapy

    DEFF Research Database (Denmark)

    Freemantle, Nick; Mamdani, Muhammad; Vilsbøll, Tina

    2015-01-01

    INTRODUCTION: IDegLira is a once-daily combination of insulin degludec (IDeg) and liraglutide. Trials directly comparing IDegLira with alternative strategies for intensifying basal insulin are ongoing. While awaiting results, this analysis compared indirectly how different strategies affected......Lira versus up-titrated IGlar. The supplementary analysis yielded similar results to the main analysis. Results with IDegLira were similar to those for the 'GLP-1RA add-on' arm. CONCLUSION: These results suggest that IDegLira may be more effective, with lower hypoglycemia rates and less weight gain, than up...

  11. Cost-effectiveness analysis of sensor-augmented pump therapy with low glucose-suspend in patients with type 1 diabetes mellitus and high risk of hypoglycemia in Spain.

    Science.gov (United States)

    Conget, Ignacio; Martín-Vaquero, Pilar; Roze, Stéphane; Elías, Isabel; Pineda, Cristina; Álvarez, María; Delbaere, Alexis; Ampudia-Blasco, Francisco Javier

    2018-05-19

    To compare the cost-effectiveness of sensor-augmented pump therapy (SAP) [continuous subcutaneous insulin infusion (CSII) plus real-time continuous glucose monitoring (RT-CGM)] with low glucose suspend (MiniMed™ Veo™) and CSII alone in patients with type 1 diabetes mellitus (T1DM) at high risk of hypoglycemia in Spain. The IQVIA CORE Diabetes Model was used to estimate healthcare outcomes as life-years gained (LYGs) and quality-adjusted life years (QALYs), and to project lifetime costs. Information about efficacy, resource utilization, and unit costs (€2016) was taken from published sources and validated by an expert panel. Analyses were performed from both the Spanish National Health System (NHS) perspective and the societal perspective. From the NHS perspective, SAP with low glucose suspend was associated to a €47,665 increase in direct healthcare costs and to increases of 0.19 LYGs and 1.88 QALYs, both discounted, which resulted in an incremental cost-effectiveness ratio (ICER) of €25,394/QALY. From the societal perspective, SAP with low glucose suspend increased total costs (including direct and indirect healthcare costs) by €41,036, with a resultant ICER of €21,862/QALY. Considering the willingness-to-pay threshold of €30,000/QALY in Spain, SAP with low glucose suspend represents a cost-effective option from both the NHS and societal perspectives. Sensitivity analyses confirmed the robustness of the model. From both the Spanish NHS perspective and the societal perspective, SAP with low glucose suspend is a cost-effective option for the treatment of T1DM patients at high risk of hypoglycemia. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. A model of insulin fibrils derived from the x-ray crystal structure of a monomeric insulin (despentapeptide insulin).

    Science.gov (United States)

    Brange, J; Dodson, G G; Edwards, D J; Holden, P H; Whittingham, J L

    1997-04-01

    The crystal structure of despentapeptide insulin, a monomeric insulin, has been refined at 1.3 A spacing and subsequently used to predict and model the organization in the insulin fibril. The model makes use of the contacts in the densely packed despentapeptide insulin crystal, and takes into account other experimental evidence, including binding studies with Congo red. The dimensions of this model fibril correspond well with those measured experimentally, and the monomer-monomer contacts within the fibril are in accordance with the known physical chemistry of insulin fibrils. Using this model, it may be possible to predict mutations in insulin that might alleviate problems associated with fibril formation during insulin therapy.

  13. Evaluation of costs accrued through inadvertent continuation of hospital-initiated proton pump inhibitor therapy for stress ulcer prophylaxis beyond hospital discharge: a retrospective chart review

    Directory of Open Access Journals (Sweden)

    Shin S

    2015-04-01

    Full Text Available Sooyoung Shin Ajou University College of Pharmacy, Yeongtong-gu, Suwon-si, Gyeonggi-do, South Korea Background: Stress ulcers and related upper gastrointestinal bleeding are well-known complications in intensive care unit (ICU patients. Proton pump inhibitor (PPI-based stress ulcer prophylaxis (SUP has been widely prescribed in noncritically ill patients who are at low risk for clinically significant bleeding, which is then injudiciously continued after hospital discharge. This study aimed to evaluate the incidence of inappropriate prescribing of PPI-based preventative therapy in ICU versus non-ICU patients that subsequently continued postdischarge, and to estimate the costs incurred by the unwarranted outpatient continuation of PPI therapy.Methods: A retrospective review of patient data at a major teaching hospital in Korea was performed. During the 4-year study period, adult patients who were newly initiated on PPI-based SUP during hospital admission and subsequently discharged on a PPI without a medical indication for such therapy were captured for data analysis. The incidence rates of inappropriate prescribing of PPIs were compared between ICU and non-ICU patients, and the costs associated with such therapy were also examined.Results: A total of 4,410 patients, more than half of the inpatient-initiated PPI users, were deemed to have been inadvertently prescribed a PPI at discharge in the absence of a medical need for acid suppression. The incidence of inappropriate outpatient continuation of the prophylaxis was higher among ICU patients compared with non-ICU patients (57.7% versus 52.2%, respectively; P=0.001. The total expenditure accrued through the continuation of nonindicated PPI therapy was approximately US$40,175.Conclusion: This study confirmed that excess usage of PPIs for SUP has spread to low-risk, non-ICU patients. The overuse of unwarranted PPI therapy can incur large health care expenditure, as well as clinical complications

  14. Insulin-like growth factor-binding protein 7 alters the sensitivity to interferon-based anticancer therapy in hepatocellular carcinoma cells.

    Science.gov (United States)

    Tomimaru, Y; Eguchi, H; Wada, H; Noda, T; Murakami, M; Kobayashi, S; Marubashi, S; Takeda, Y; Tanemura, M; Umeshita, K; Doki, Y; Mori, M; Nagano, H

    2010-05-11

    A striking efficiency of interferon (IFN)-based anticancer therapy for advanced hepatocellular carcinoma (HCC) has been reported. Because its clinical efficiency greatly depends on each patient's local response, prediction of local response is crucial. Continuous exposure of IFN-alpha to parental PLC/PRF/5 cells (PLC-P) and a limiting dilution method resulted in the establishment of IFN-resistant cell clones (PLC-Rs). Microarray analyses of PLC-P and PLC-Rs identified insulin-like growth factor-binding protein 7 (IGFBP7) as one of the most significantly downregulated genes in PLC-Rs. Changes in anticancer effects of IFN-alpha were examined in HCC cells after genetic manipulation of IGFBP7 expression. The correlation between immunohistochemically determined IGFBP7 expression and the response to IFN-alpha/5-fluorouracil (5-FU) therapy was investigated in surgically resected HCC specimens. PLC-R cells showed a remarkable downregulation of IGFBP7 and resistance to IFN-alpha, compared with PLC-P. Parental PLC/PRF/5 cells transfected with short hairpin RNA against IGFBP7 showed a significant resistance to IFN-alpha relative to control cells (IC(50) fold increase=14.38 times). Insulin-like growth factor-binding protein 7 transfection into PLC-R restored sensitivity to IFN-alpha. In resected specimens, IGFBP7 expression significantly correlated with the response to IFN-alpha/5-FU therapy. IGFBP7 could be a useful predictor of the response to IFN-based therapy in advanced HCC.

  15. Placebo-controlled comparison of captopril, metoprolol, and hydrochlorothiazide therapy in non-insulin-dependent diabetic patients with primary hypertension

    DEFF Research Database (Denmark)

    Gall, M A; Rossing, P; Skøtt, P

    1992-01-01

    The antihypertensive effect of captopril, metoprolol, and hydrochlorothiazide was compared in 23 non-insulin-dependent (NIDDM) diabetic patients less than or equal to 75 years of age, with borderline to moderate primary hypertension. In a double blind, placebo-controlled cross-over trial...

  16. Supervised exercise training counterbalances the adverse effects of insulin therapy in overweight/obese subjects with type 2 diabetes.

    Science.gov (United States)

    Balducci, Stefano; Zanuso, Silvano; Cardelli, Patrizia; Salerno, Gerardo; Fallucca, Sara; Nicolucci, Antonio; Pugliese, Giuseppe

    2012-01-01

    To examine the effect of supervised exercise on traditional and nontraditional cardiovascular risk factors in sedentary, overweight/obese insulin-treated subjects with type 2 diabetes from the Italian Diabetes Exercise Study (IDES). The study randomized 73 insulin-treated patients to twice weekly supervised aerobic and resistance training plus structured exercise counseling (EXE) or to counseling alone (CON) for 12 months. Clinical and laboratory parameters were assessed at baseline and at the end of the study. The volume of physical activity was significantly higher in the EXE versus the CON group. Values for hemoglobin A(1c), BMI, waist circumference, high-sensitivity C-reactive protein, blood pressure, LDL cholesterol, and the coronary heart disease risk score were significantly reduced only in the EXE group. No major adverse events were observed. In insulin-treated subjects with type 2 diabetes, supervised exercise is safe and effective in improving glycemic control and markers of adiposity and inflammation, thus counterbalancing the adverse effects of insulin on these parameters.

  17. Continuous subcutaneous insulin infusion in diabetes: patient populations, safety, efficacy, and pharmacoeconomics

    OpenAIRE

    Pozzilli, Paolo; Battelino, Tadej; Danne, Thomas; Hovorka, Roman; Jarosz?Chobot, Przemyslawa; Renard, Eric

    2015-01-01

    Summary The level of glycaemic control necessary to achieve optimal short?term and long?term outcomes in subjects with type 1 diabetes mellitus (T1DM) typically requires intensified insulin therapy using multiple daily injections or continuous subcutaneous insulin infusion. For continuous subcutaneous insulin infusion, the insulins of choice are the rapid?acting insulin analogues, insulin aspart, insulin lispro and insulin glulisine. The advantages of continuous subcutaneous insulin infusion ...

  18. Hyperparathyroidism Associated with Long-Term Proton Pump Inhibitors Independent of Concurrent Bisphosphonate Therapy in Elderly Adults.

    Science.gov (United States)

    Hinson, Andrew M; Wilkerson, Bekka M; Rothman-Fitts, Ivy; Riggs, Ann T; Stack, Brendan C; Bodenner, Donald L

    2015-10-01

    To measure the effect of proton pump inhibitors (PPIs), with and without concurrent bisphosphonates, on parathyroid hormone (PTH), vitamin D, and calcium. Retrospective chart review of individuals 60 years and older. Subjects with reduced renal function (creatinine >1.3 mg/dL) and low vitamin D (hyperparathyroidism regardless of concurrent oral BP administration. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  19. Insulin therapy in diabetes and cancer risk: current understanding and implications for future study: proceedings from a meeting of a European Insulin Safety Consensus Panel, convened and sponsored by Novo Nordisk, held Tuesday October 5, 2010 at The Radisson Edwardian Heathrow Hotel, Hayes, Middlesex, UK.

    Science.gov (United States)

    Gough, Stephen C L; Belda-Iniesta, Cristóbal; Poole, Christopher; Weber, Matthias; Russell-Jones, David; Hansen, Bo Falck; Mannucci, Edoardo; Tuomilehto, Jaakko

    2011-09-01

    Interest in the possibility of certain insulin treatments having the potential to modify cancer development and prognosis was reawakened in 2009, following publication of several epidemiological studies addressing this issue. This interest extends to how diabetes itself and cancer might be linked, and makes desirable an exchange of expert views and knowledge to enhance understanding in this subject among those treating diabetes and cancer, or those developing diabetes therapies. A European meeting was convened with participants invited based on known relevant interests in endocrinology, oncology, epidemiology, and insulin analog design and investigation. Experts in these fields were invited to present on relevant topics, with open discussions held after each presentation. Concern over the potential mitogenic properties of certain insulin analogs has arisen from some (but not all) epidemiological studies, although confounding factors render interpretation controversial. Future epidemiological studies are likely to strengthen confidence in drawing conclusions. Meanwhile, pharmacological studies, and a consideration of cancer pathophysiology, implicate increased insulin-like growth factor-1 receptor affinity, and/or deranged insulin receptor interaction/signaling properties as possible a priori causes for concern with some insulin analogs. Again, interpretation of the body of pharmacological evidence is confounded by the array of test systems and methodologies used, and by studies frequently succumbing to methodological pitfalls. Reassuringly, most available insulin analogs do not differ in their receptor interaction response profile to human insulin, and for those that do there are reasons to question any potential clinical relevance. Nevertheless, it is desirable that new experimental models are devised that can better determine the likely clinical consequences of any variance in receptor response profile versus human insulin. More data are required to increase our

  20. Phase III Study on Efficacy and Safety of Triple Combination (Exenatide/Metformin/Biphasic Insulin Aspart) Therapy for Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Su, Ke; Lv, Chunmei; Ji, Zongwen; Wang, Yishu; Wang, Haifeng; Bai, Ying; Liu, Yaping

    2016-02-03

    Exenatide, metformin (MET), and biphasic insulin aspart 30 (BIA30) have been widely used in the treatment of patients with type 2 diabetes mellitus (T2DM); however, each of these medications has significant adverse effects, which limit their utilization. This study aimed to evaluate the efficacy and safety of triple combination (exenatide/metformin/biphasic insulin aspart) therapy for T2DM. Two hundred patients with poorly controlled T2DM were randomly divided into the low-dose (0.5 μg exenatide, 0.05 U·kg·d BIA30, and 0.01 g MET twice daily) and normal-dose (2 μg exenatide, 0.2 U·kg·d BIA30, and 0.05 g MET twice daily) groups for 48 weeks of treatment. Of note, 82 and 90 individuals from the low-dose and normal-dose groups, respectively, completed the study. The levels of adiponectin, C-reactive protein, tumor necrosis factor-α, and resistin were measured. The normal-dose treatment was more effective at lowering hemoglobin A1c levels than the low-dose therapy (HbA1c changes of -2.5 ± 0.19% and -0.8 ± 0.07%, respectively) after 48 weeks. The maximum weight decrease was 0.9 kg in the low-dose group and 4.0 kg in the normal-dose group. The triple combination therapy increased the levels of insulin sensitivity and adiponectin and reduced the levels of C-reactive protein, resistin, and tumor necrosis factor-α. No significant difference in the adverse effects was found between the low-dose and normal-dose groups (P > 0.05). In conclusion, the investigated triple combination therapy for T2MD is therefore an effective and safe therapeutic strategy.This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND), which permits downloading and sharing the work provided it is properly cited. The work cannot be changed in any way or used commercially.

  1. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  2. Feasibility and efficacy of an isocaloric high-protein vs. standard diet on insulin requirement, body weight and metabolic parameters in patients with type 2 diabetes on insulin therapy

    DEFF Research Database (Denmark)

    Luger, M; Holstein, B; Schindler, K

    2013-01-01

    To determine the feasibility and efficacy of a high-protein diet compared with a standard diet aiming for weight maintenance in insulin treated type-2 diabetic patients on insulin requirement, body weight and metabolic parameters over 12 weeks.......To determine the feasibility and efficacy of a high-protein diet compared with a standard diet aiming for weight maintenance in insulin treated type-2 diabetic patients on insulin requirement, body weight and metabolic parameters over 12 weeks....

  3. Effect of non-surgical periodontal therapy on insulin resistance in patients with type II diabetes mellitus and chronic periodontitis, as assessed by C-peptide and the Homeostasis Assessment Index.

    Science.gov (United States)

    Mammen, Jerry; Vadakkekuttical, Rosamma Joseph; George, Joseraj Manaloor; Kaziyarakath, Jaishid Ahadal; Radhakrishnan, Chandni

    2017-08-01

    A bidirectional relationship exists between diabetes and periodontitis. In the present clinical trial, we evaluated the effects of non-surgical periodontal therapy (NSPT) on insulin resistance in patients with type II diabetes mellitus (DM) and chronic periodontitis. Forty chronic periodontitis patients with type II DM were selected and equally allocated to case and control groups. All patients were assessed for periodontal parameters and systemic parameters. The case group received NSPT, and both groups were re-evaluated after 3 months. All periodontal parameters were found to be significantly improved in the case group compared to the control group 3 months after NSPT. The mean differences in systemic parameters, such as fasting serum C-peptide, Homeostasis Assessment (HOMA) Index-insulin resistance, and HOMA-insulin sensitivity, from baseline to 3 months for the case group were 0.544 ± 0.73, 0.54 ± 0.63, and -25.44 ± 36.81, respectively; for the control group, they were significant at -1.66 ± 1.89, -1.48 ± 1.86, and 31.42 ± 38.82 respectively (P periodontal inflammation could affect glycemic control and insulin resistance. Effective periodontal therapy reduced insulin resistance and improved periodontal health status and insulin sensitivity in patients with type II DM and chronic periodontitis. © 2016 John Wiley & Sons Australia, Ltd.

  4. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  5. Insulin Secretagogues

    Science.gov (United States)

    ... than sulfonylureas. What are the side effects and disadvantages of insulin secretagogues? Both types of insulin-releasing ... help find the cause. Questions to ask your doctor What else can I do to keep my ...

  6. Vildagliptin as add-on therapy to insulin improves glycemic control without increasing risk of hypoglycemia in Asian, predominantly Chinese, patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Ning, Guang; Wang, Weiqing; Li, Ling; Ma, Jianhua; Lv, Xiaofeng; Yang, Ming; Wang, Wei; Woloschak, Michael; Lukashevich, Valentina; Kothny, Wolfgang

    2016-05-01

    The aim of the present study was to investigate the efficacy and safety of vildagliptin added onto insulin with or without metformin in an Asian, predominantly Chinese, population with type 2 diabetes mellitus (T2DM). In this 24-week, multicenter, double-blind, placebo-controlled trial, patients with T2DM inadequately controlled (HbA1c 7.5%-11.0%) on stable therapy with long-acting, intermediate-acting, or premixed insulin, with or without concomitant metformin, were randomized to receive vildagliptin 50 mg b.i.d. or placebo. Of 293 patients randomized, 146 received vildagliptin and 147 received placebo treatment. At baseline, the overall mean age of patients was 58.1 years, mean T2DM duration was 11.3 years, and mean HbA1c was 8.7%. The adjusted mean (±SE) change in HbA1c at Week 24 in the vildagliptin and placebo groups was -1.08 ± 0.12% and -0.38 ± 0.12%, respectively (between-treatment difference -0.70 ± 0.16%; P vildagliptin than with placebo (23.6% vs. 11.2%; P = 0.006). The incidence of adverse events in the vildagliptin and placebo groups was 43.8% and 46.3%, whereas that of serious adverse events was 3.4% and 6.8%, respectively. The frequency of hypoglycemia was lower in the vildagliptin than placebo group (2.7% vs. 5.4%). The addition of vildagliptin 50 mg b.i.d. significantly improved glycemic control without an increased risk of hypoglycemia in Asian, predominantly Chinese, patients with T2DM inadequately controlled on insulin, with or without metformin. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley Sons Australia, & Ltd.

  7. Budget impact of continuous subcutaneous insulin infusion therapy in patients with type 1 diabetes who experience severe recurrent hypoglycemic episodes in Spain.

    Science.gov (United States)

    Giménez, Marga; Elías, Isabel; Álvarez, María; Quirós, Carmen; Conget, Ignacio

    Hypoglycemia is one of the most common complications to achieve a good metabolic control, and has been listed by several scientific associations as a common indication to start treatment with continuous subcutaneous insulin infusion (CSII). Use of CSII is still residual in Spain as compared to neighbouring countries, and cost of acquisition cost is one of the main reasons. This study estimates the budget impact of treatment with CSII, as compared to multiple daily insulin injections, of patients with type 1 diabetes mellitus who experience recurrent severe hypoglycemia episodes from the National Healthcare System perspective. Budget impact was based on a retrospective, observational study evaluating the efficacy of CSII in patients with type 1 diabetes mellitus conducted at Hospital Clínic i Universitari in Barcelona, where one of the main indications for switching to CSII were recurrent severe hypoglycemia episodes. The mean number of annual episodes was 1.33 in the two years prior to CSII start and 0.08 in the last two years of follow up (p=0.003). Costs of treatment and major hypoglycemic events over a four-year period were considered. Costs were taken from different Spanish data sources and expressed in € of 2016. Treatment with CSII increased costs by €9,509 per patient as compared to multiple daily insulin injections (€11,902-€2,393). Cost associated to severe hypoglycemic events decreased by €19,330 per patient treated with CSIII (€1,371-€20,701). Results suggest mean total savings of €9,821 per patient during the four-year study period. The higher costs associated to CSII therapy may be totally offset by the severe hypoglycemic events prevented. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Impact of a Serious Videogame Designed for Flexible Insulin Therapy on the Knowledge and Behaviors of Children with Type 1 Diabetes: The LUDIDIAB Pilot Study.

    Science.gov (United States)

    Joubert, Michael; Armand, Coline; Morera, Julia; Tokayeva, Leyla; Guillaume, Aurore; Reznik, Yves

    2016-02-01

    Flexible (or functional) insulin therapy method is a self-management education approach for intensive insulin therapy in patients with type 1 diabetes. The serious game (or applied game) "L'Affaire Birman" ("Mr. Birman's File") (available at www.gluciweb.com ) was specifically designed as an educational tool for the flexible insulin therapy method. Its educational impact was evaluated in children with type 1 diabetes. This prospective multicenter pilot study evaluated the effect of this videogame on the therapeutic knowledge and behavior of children with type 1 diabetes. PedCarbQuiz (PCQ) and Diabetes Self-Management Profile (DSMP) questionnaires were used before (T0), immediately after (T1), and 6 months after (T2) the unstructured use of the videogame. The 38 children enrolled in the study were 42% boys and 58% girls; they had a mean age of 13.7 ± 2.1 years old, a diabetes duration of 6.0 ± 3.8 years, and hemoglobin A1c (HbA1c) levels of 8.5 ± 1.4% (69.4 ± 9.4 mmol/mol). The children connected to the game 3.3 ± 2.8 times during this 6-month study. Their PCQ score increased from 31.6 ± 4.9 at T0 to 36.0 ± 4.0 at T2 (P < 0.05). Two PCQ subscores also increased significantly: the insulin titration score at T1 and T2 and the carbohydrate quantification score at T2. Conversely, the DSMP score was not different at T0, T1, and T2 (59.1 ± 9.9, 60.2 ± 9.8, and 60.0 ± 10.0, respectively), and HbA1c levels also remained stable throughout the study (8.4 ± 1.3%, 8.4 ± 1.2%, and 8.5 ± 1.5% at T0, T1, and T2, respectively). Subgroup analysis found a greater impact of the game in children with poor glycemic control and low knowledge at baseline. Adherence to the game was rather low (half of the children played less than 2.5 bouts), but no criterion was found to be predictive of this low attractiveness. Nonsupervised usage of the serious game "L'Affaire Birman" was able to improve insulin titration and

  9. Sodium-glucose co-transporter 2 inhibitors in addition to insulin therapy for management of type 2 diabetes mellitus: A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Tang, Huilin; Cui, Wei; Li, Dandan; Wang, Tiansheng; Zhang, Jingjing; Zhai, Suodi; Song, Yiqing

    2017-01-01

    Given inconsistent trial results of sodium-glucose cotransporter 2 (SGLT2) inhibitors in addition to insulin therapy for treating type 2 diabetes mellitus (T2DM), a meta-analysis was performed to evaluate the efficacy and safety of this combination for T2DM by searching available randomized trials from PubMed, Embase, CENTRAL and ClinicalTrials.gov. Our meta-analysis included seven eligible placebo-controlled trials involving 4235 patients. Compared with placebo, SGLT2 inhibitor treatment was significantly associated with a mean reduction in HbA1c of -0.56%, fasting plasma glucose of -0.95 mmol/L, body weight of -2.63 kg and insulin dose of -8.79 IU, but an increased risk of drug-related adverse events by 36%, urinary tract infections by 29% and genital infections by 357%. No significant increase was observed in risk of overall adverse events [risk ratio (RR), 1.00], serious adverse events (RR, 0.90), adverse events leading to discontinuation (RR, 1.16), hypoglycaemia events (RR, 1.07) and severe hypoglycaemia events (RR, 1.24). No diabetic ketoacidosis events were reported. Further studies are needed to establish optimal combination type and dose. © 2016 John Wiley & Sons Ltd.

  10. Comparison of health care resource utilization and costs among patients with GERD on once-daily or twice-daily proton pump inhibitor therapy

    Directory of Open Access Journals (Sweden)

    Mody R

    2013-04-01

    Full Text Available Reema Mody,1 Debra Eisenberg,2 Likun Hou,2 Siddhesh Kamat,2 Joseph Singer,2 Lauren B Gerson3 1Takeda Pharmaceuticals International Inc, Deerfield, IL, 2HealthCore Inc, Wilmington, DE, 3Stanford University School of Medicine, Stanford, CA, USA Background: The purpose of this study was to assess differences in health care resource utilization and costs associated with once-daily and twice-daily proton pump inhibitor (PPI therapy. Most patients with gastroesophageal reflux disease (GERD achieve symptom control on once-daily PPI therapy, but approximately 20%–30% require twice-daily dosing. Methods: Patients were ≥18 years of age with at least one medical claim for GERD and at least two PPI claims from HealthCore's Integrated Research Database (HIRDSM during 2004–2009. Patients were continuously eligible for 12 months before and after the index date (date of first PPI claim. Based on PPI dosing throughout the post-index period (quantity of medication dispensed/number of days supply, patients were classified as once-daily (dose ≤ 1.5 pills per day or twice-daily (≥1.5 PPI users. Results: The study cohort included 248,386 patients with GERD (mean age 52.8 ± 13.93 years, 56% females of whom 90% were once-daily and 10% were twice-daily PPI users. The Deyo-Charlson Comorbidity Index for once-daily and twice-daily PPI users was 0.70 ± 1.37 and 0.89 ± 1.54, respectively (P < 0.05. More once-daily patients had claims for Barrett's esophagus (5% versus 2%, P < 0.0001 than twice-daily patients. Post-index, higher proportions of twice-daily patients had at least one GERD-related inpatient visit (7% versus 5%, outpatient visit (60% versus 49%, and office visit (48% versus 38% versus once-daily patients (P < 0.0001. Mean total GERD-related health care costs were $2065 ± $6636 versus $3749 ± $11,081 for once-daily and twice-daily PPI users, respectively (P < 0.0001. Conclusion: Patients receiving twice-daily PPI therapy were likely to have more

  11. Continuous subcutaneous insulin infusion versus multiple daily injections: the impact of baseline A1c

    NARCIS (Netherlands)

    Retnakaran, Ravi; Hochman, Jackie; DeVries, J. Hans; Hanaire-Broutin, Helene; Heine, Robert J.; Melki, Vincent; Zinman, Bernard

    2004-01-01

    Rapid-acting insulin analogs (insulin lispro and insulin aspart) have emerged as the meal insulin of choice in both multiple daily insulin injection (MDII) therapy and continuous subcutaneous insulin infusion (CSII) for type 1 diabetes. Thus, a comparison of efficacy between CSII and MDII should be

  12. Dapagliflozin as an adjunct therapy to insulin in the treatment of patients with type 1 diabetes mellitus

    OpenAIRE

    Tamez, Hector E.; Tamez, Alejandra L.; Garza, Lucas A.; Hernandez, Mayra I.; Polanco, Ana C.

    2015-01-01

    We have evaluated the efficacy of dapagliflozin in patients with type 1 diabetes mellitus (DM1) without adequate control. We expected that adding dapagliflozin to this population on top of their base treatment would lower their HbA1c levels. We conducted a pragmatic, open, 24-week study of treatment with 10 mg of oral dapagliflozin in patients with DM1 and chronic hyperglycemia. We evaluated glycemic control, lipid profile, weight, and insulin dose. Safety was assessed by adverse event report...

  13. Insulin resistance change and antiretroviral therapy exposure in HIV-infected and uninfected Rwandan women: a longitudinal analysis.

    Science.gov (United States)

    Mutimura, Eugene; Hoover, Donald R; Shi, Qiuhu; Dusingize, Jean Claude; Sinayobye, Jean D'Amour; Cohen, Mardge; Anastos, Kathryn

    2015-01-01

    We longitudinally assessed predictors of insulin resistance (IR) change among HIV-uninfected and HIV-infected (ART-initiators and ART-non-initiators) Rwandan women. HIV-infected (HIV+) and uninfected (HIV-) women provided demographic and clinical measures: age, body mass index (BMI) in Kg/(height in meters)2, Fat-Mass (FMI) and Fat-Free-Mass (FFMI) index, fasting serum glucose and insulin. Homeostasis Model Assessment (HOMA) was calculated to estimate IR change over time in log10 transformed HOMA measured at study enrollment or prior to ART initiation in 3 groups: HIV- (n = 194), HIV+ ART-non-initiators (n=95) and HIV+ ART-initiators (n=371). ANCOVA linear regression models of change in log10-HOMA were fit with all models included the first log10 HOMA as a predictor. Mean±SD log10-HOMA was -0.18±0.39 at the 1st and -0.21±0.41 at the 2nd measure, with mean change of 0.03±0.44. In the final model (all women) BMI at 1st HOMA measure (0.014; 95% CI=0.006-0.021 per kg/m2; pchange in BMI from 1st to 2nd measure (0.024; 95% CI=0.013-0.035 per kg/m2; pchange. When restricted to subjects with FMI measures, FMI at 1st HOMA measure (0.020; 95% CI=0.010-0.030 per kg/m2; pchange in FMI from 1st to 2nd measure (0.032; 95% CI=0.020-0.043 per kg/m2; pchange in HOMA. While ART use did not predict change in log10-HOMA, untreated HIV+ women had a significant decline in IR over time. Use or duration of AZT, d4T and EFV was not associated with HOMA change in HIV+ women. Baseline BMI and change in BMI, and in particular fat mass and change in fat mass predicted insulin resistance change over ~3 years in HIV-infected and uninfected Rwandan women. Exposure to specific ART (d4T, AZT, EFV) did not predict insulin resistance change in ART-treated HIV-infected Rwandan women.

  14. A novel reflux inhibitor lesogaberan (AZD3355) as add-on treatment in patients with GORD with persistent reflux symptoms despite proton pump inhibitor therapy: a randomised placebo-controlled trial

    NARCIS (Netherlands)

    Boeckxstaens, Guy E.; Beaumont, Hanneke; Hatlebakk, Jan G.; Silberg, Debra G.; Björck, Karin; Karlsson, Maria; Denison, Hans

    2011-01-01

    o evaluate the efficacy and tolerability of add-on treatment with lesogaberan (AZD3355), a novel reflux inhibitor, in patients with persistent gastro-oesophageal reflux disease (GORD) symptoms despite proton pump inhibitor (PPI) therapy. double-blind, placebo-controlled, randomised, parallel-group,

  15. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  16. Effectiveness of resistance exercise compared to aerobic exercise without insulin therapy in patients with type 2 diabetes mellitus: a meta-analysis.

    Science.gov (United States)

    Nery, Cybelle; Moraes, Silvia Regina Arruda De; Novaes, Karyne Albino; Bezerra, Márcio Almeida; Silveira, Patrícia Verçoza De Castro; Lemos, Andrea

    Physical exercise has been used to mitigate the metabolic effects of diabetes mellitus. To evaluate the effect of resistance exercise when compared to aerobic exercise without insulin therapy on metabolic and clinical outcomes in patients with type 2 diabetes mellitus. Papers were searched on the databases MEDLINE/PubMed, CINAHL, SPORTDiscus, LILACS, and SCIELO, without language or date of publication limits. Clinical trials that compared resistance exercise to aerobic exercise in adults with type 2 diabetes mellitus who did not use insulin therapy were included. The quality of evidence and risk of bias were assessed using the GRADE system and the Cochrane Risk of Bias tool, respectively. Meta-analysis was also used, whenever possible. Two reviewers extracted the data independently. Eight eligible articles were included in this study, with a total of 336 individuals, with a mean age of 48-58 years. The protocols of aerobic and resistance exercise varied in duration from eight to 22 weeks, 30-60min/day, three to five times/week. Overall the available evidence came from a very low quality of evidence and there was an increase in Maximal oxygen consumption (mean difference: -2.86; 95% CI: -3.90 to -1.81; random effect) for the resistance exercise and no difference was found in Glycated hemoglobin, Body mass index, High-density lipoprotein cholesterol, Low-density lipoprotein cholesterol, triglycerides, and total cholesterol. Resistance exercise appears to be more effective in promoting an increase in Maximal oxygen consumption in protocols longer than 12 weeks and there is no difference in the control of glycemic and lipid levels between the two types of exercise. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Changes in HbA1c and Weight Following Transition to Continuous Subcutaneous Insulin Infusion Therapy in Adults With Type 1 Diabetes.

    Science.gov (United States)

    Mehta, Sanjeev N; Andersen, Henrik Ullits; Abrahamson, Martin J; Wolpert, Howard A; Hommel, Eva E; McMullen, William; Ridderstråle, Martin

    2017-01-01

    Historically, intensive insulin therapy for type 1 diabetes (T1D) has improved glycemic control at the risk of adverse weight gain. The impact of continuous subcutaneous insulin infusion therapy (CSII) on weight in the current era remains unknown. We assessed changes in hemoglobin A1c (HbA1c) and weight in adults with T1D transitioning to CSII at 2 diabetes centers in Denmark and the United States. Patients with T1D, aged ≥18 years, managed with multiple daily injections (MDI) who transitioned to CSII between 2002 and 2013 were identified using electronic health record data from the Steno Diabetes Center (n = 600) and Joslin Diabetes Center (n = 658). Changes in HbA1c and weight after 1 year was assessed overall and by baseline HbA1c cut points. Multivariate regression assessed correlates of HbA1c reduction. In adults with T1D transitioning to CSII, clinically significant HbA1c reductions were found in patients with baseline HbA1c 8.0-8.9% (Steno, -0.7%; Joslin, -0.4%) and baseline HbA1c ≥9.0% (Steno, -1.1%; Joslin, -0.9%) ( P HbA1c ≥9% at Steno (1.1 ± 0.3 kg, P HbA1c reduction was associated with higher HbA1c, older age, female sex at Steno ( R 2 = .28, P HbA1c at Joslin ( R 2 = .19, P HbA1c without a negative impact on weight 1 year after transitioning from MDI to CSII.

  18. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  19. Diabetes Technology-Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Peters, Anne L; Ahmann, Andrew J; Battelino, Tadej; Evert, Alison; Hirsch, Irl B; Murad, M Hassan; Winter, William E; Wolpert, Howard

    2016-11-01

    To formulate clinical practice guidelines for the use of continuous glucose monitoring and continuous subcutaneous insulin infusion in adults with diabetes. The participants include an Endocrine Society-appointed Task Force of seven experts, a methodologist, and a medical writer. The American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology co-sponsored this guideline. The Task Force developed this evidence-based guideline using the Grading of Recommendations, Assessment, Development, and Evaluation system to describe the strength of recommendations and the quality of evidence. The Task Force commissioned one systematic review and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of the Endocrine Society, the American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Continuous subcutaneous insulin infusion and continuous glucose monitoring have an important role in the treatment of diabetes. Data from randomized controlled trials are limited on the use of medical devices, but existing studies support the use of diabetes technology for a wide variety of indications. This guideline presents a review of the literature and practice recommendations for appropriate device use.

  20. Glucose-responsive insulin delivery for type 1 diabetes: The artificial pancreas story.

    Science.gov (United States)

    Bally, Lia; Thabit, Hood; Hovorka, Roman

    2018-06-15

    Insulin replacement therapy is integral to the management of type 1 diabetes, which is characterised by absolute insulin deficiency. Optimal glycaemic control, as assessed by glycated haemoglobin, and avoidance of hyper- and hypoglycaemic excursions have been shown to prevent diabetes-related complications. Insulin pump use has increased considerably over the past decade with beneficial effects on glycaemic control, quality of life and treatment satisfaction. The advent and progress of ambulatory glucose sensor technology has enabled continuous glucose monitoring based on real-time glucose levels to be integrated with insulin therapy. Low glucose and predictive low glucose suspend systems are currently used in clinical practice to mitigate against hypoglycaemia, and provide the first step towards feedback glucose control. The more advanced technology approach, an artificial pancreas or a closed-loop system, gradually increases and decreases insulin delivery in a glucose-responsive fashion to mitigate against hyper- and hypoglycaemia. Randomised outpatient clinical trials over the past 5 years have demonstrated the feasibility, safety and efficacy of the approach, and the recent FDA approval of the first single hormone closed-loop system establishes a new standard of care for people with type 1 diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. [Acupuncture and Chinese medicine of artificial cycle therapy for insulin resistance of polycystic ovary syndrome with phlegm damp type and its mechanism].

    Science.gov (United States)

    Yang, Juan; Liu, Ying; Huang, Jian; Xu, Jinbang; You, Xiumi; Lin, Qiuping; Zhang, Junxin; Dun, Jingjing; Huang, Shan

    2017-11-12

    To explore the effect difference between acupuncture combined with Chinese medicine of artificial cycle therapy on the basis of western medication and simple western medication for polycystic ovarian syndrome (PCOS) of phlegm damp type with insulin resistance, and to explore its mechanism. Sixty patients were randomly assigned into an observation group and a control group, 30 cases in each group. Patients of the control group began to take letrozole and metformin orally on the third menstrual day. Patients of the observation group were treated with acupuncture combined with Chinese medicine of artificial cycle therapy on the basis of the treatment of the control group. The main acupoints were Guanyuan (CV 4), Qihai (CV 6) and bilateral Zigong (EX-CA 1), Luanchao (Extra), Fenglong (ST 40), Yinlingquan (SP 9), Zusanli (ST 36), Sanyinjiao (SP 6). Dahe (KI 12) was matched in the follicular phase, and warm acupuncture was applied at Guanyuan (CV 4) and Qihai (CV 6); Zhongji (CV 3) and Xuehai (SP 10) were matched in the ovulatory phase, and electroacupuncture were used at Qihai (CV 6) and Zhongji (CV 3), Xuehai (SP 10) and Yinlingquan (SP 9), 2 Hz and continuous wave; The acupoints in the luteal phase were the above main acupoints, at the same time, moxibustion was used at Guanyuan (CV 4) and Qihai (CV 6), the treatment was given once every other day, 30 min a time. There was no treatment in the menstrual phase. Chinese medicine was applied for tonifying kidney and nourishing blood, strengthening spleen and eliminating phlegm. The patients of the two groups were treated for continuous three menstrual cycles. The indexes before and after treatment were detected, including serum microRNA-29 (miR-29) expression, TCM symptom score, insulin (INS), blood-sugar content and homeostasis model assessment-insulin resistance (HOMA-IR) index, the endocrine hormone values of follicle stimulating hormone (FSH), luteinizing hormone (LH), testosterone (T), LH/FSH ratio, prolactin (PRL

  2. Predictive value of glucose-insulin ratio in PCOS and profile of women who will benefit from metformin therapy: obese, lean, hyper or normoinsulinemic?

    Science.gov (United States)

    Onalan, Gogsen; Goktolga, Umit; Ceyhan, Temel; Bagis, Tayfun; Onalan, Reside; Pabuçcu, Recai

    2005-12-01

    The aim of the present study is to evaluate sub-groups of PCOS patients who will benefit from metformin therapy and to find out any predictors of ovulation in PCOS sub-groups. In the current prospective-randomized, placebo-controlled, double-blind study, PCOS patients (n = 116) were divided into six main groups according to glucose to insulin ratio (G-I ratio mg/10(-4) U) and body mass index (BMI kg/m2) as: Group 1: normoinsulinemic (G-I ratio > or = 4.5 mg/10(-4) U), lean (BMI or = 30) (n = 18); Group 4: hyperinsulinemic (G-I ratio lean (n = 28); Group 5: hyperinsulinemic, overweight (n = 17); Group 6: hyperinsulinemic, obese (n = 20). Patients in each group were randomized onto placebo or metformin treatments (850 mg two to three times per day according to BMI). The rate of ovulation, biochemical profile, hormonal profile and clinical symptoms of hyperandrogenism were evaluated before and after 6 months of metformin and placebo treatments. We observed a significant decrease in WHR following metformin therapy in the normoinsulinemic overweight sub-group (P lean women (P lean hyperinsulinemic and normoinsulinemic groups (P lean hyperinsulinemic women (P PCOS patients.

  3. Treatment Discontinuation and Clinical Events in Type 2 Diabetes Patients Treated with Dipeptidyl Peptidase-4 Inhibitors or NPH Insulin as Third-Line Therapy

    Directory of Open Access Journals (Sweden)

    Cristiano S. Moura

    2018-01-01

    Full Text Available Objective. To compare dipeptidyl peptidase-4 (DPP-4 inhibitors with neutral protamine Hagedorn (NPH insulin, in terms of effectiveness and safety for the management of patients with type 2 diabetes mellitus (DM2 not controlled on metformin and sulfonylureas. Methods. A retrospective cohort study of individuals with DM2 newly dispensed with either DPP-4 inhibitors or NPH as third-line therapy, after metformin and sulfonylurea. Treatment discontinuation, macrovascular outcomes, and hypoglycemia were compared using multivariable Cox regression models, adjusted for sex, age, year of cohort entry, place of residence, hypertension, past history of hypoglycemia, diabetic ketoacidosis, comorbidities, and number of visits to emergency departments, outpatient physician, and hospitalizations. Results. Treatment discontinuation and hypoglycemia occurred more frequently with NPH than with DPP-4 inhibitor users. In the adjusted Cox model, the use of NPH compared to that of DPP-4 inhibitors was associated with a higher risk of discontinuation (HR: 1.33; 95% CI 1.27–1.40 and hypoglycemia (HR: 2.98; 95% CI 2.72–3.28. Risk of cardiovascular events was similar across groups. Conclusions. This real-world analysis suggests that DM2 patients initiating third-line therapy with NPH have poorer control of diabetes when compared to DPP-4 inhibitor initiators.

  4. Local myocardial insulin-like growth factor 1 (IGF-1) delivery with biotinylated peptide nanofibers improves cell therapy for myocardial infarction

    Science.gov (United States)

    Davis, Michael E.; Hsieh, Patrick C. H.; Takahashi, Tomosaburo; Song, Qing; Zhang, Shuguang; Kamm, Roger D.; Grodzinsky, Alan J.; Anversa, Piero; Lee, Richard T.

    2006-05-01

    Strategies for cardiac repair include injection of cells, but these approaches have been hampered by poor cell engraftment, survival, and differentiation. To address these shortcomings for the purpose of improving cardiac function after injury, we designed self-assembling peptide nanofibers for prolonged delivery of insulin-like growth factor 1 (IGF-1), a cardiomyocyte growth and differentiation factor, to the myocardium, using a "biotin sandwich" approach. Biotinylated IGF-1 was complexed with tetravalent streptavidin and then bound to biotinylated self-assembling peptides. This biotin sandwich strategy allowed binding of IGF-1 but did not prevent self-assembly of the peptides into nanofibers within the myocardium. IGF-1 that was bound to peptide nanofibers activated Akt, decreased activation of caspase-3, and increased expression of cardiac troponin I in cardiomyocytes. After injection into rat myocardium, biotinylated nanofibers provided sustained IGF-1 delivery for 28 days, and targeted delivery of IGF-1 in vivo increased activation of Akt in the myocardium. When combined with transplanted cardiomyocytes, IGF-1 delivery by biotinylated nanofibers decreased caspase-3 cleavage by 28% and increased the myocyte cross-sectional area by 25% compared with cells embedded within nanofibers alone or with untethered IGF-1. Finally, cell therapy with IGF-1 delivery by biotinylated nanofibers improved systolic function after experimental myocardial infarction, demonstrating how engineering the local cellular microenvironment can improve cell therapy. engineering | maturation | scaffold

  5. Assessment of feasibility and efficacy of Class IV laser therapy for postoperative pain relief in off-pump coronary artery bypass surgery patients: A pilot study

    Directory of Open Access Journals (Sweden)

    Anil Karlekar

    2015-01-01

    Full Text Available Background: Laser therapy, for its established analgesic properties with minimal side effects, has been used for the treatment of chronic pain. However, it has not been used for the treatment of acute postoperative pain. This pilot study was designed to assess the feasibility and efficacy of Class IV laser on postoperative pain relief following off-pump coronary artery bypass graft (OPCABG surgery, as a component of multimodal analgesia (MMA technique. Methods: This open observational prospective study comprised of 100 adult patients (84 male, 16 female who underwent OPCABG through sternotomy. For postoperative analgesia, they were subjected to laser therapy subjected to laser therapy in addition to the standard institutional pain management protocol comprising of IV infusion/bolus of tramadol and paracetamol and fentanyl bolus as rescue analgesic. Pain intensity was measured by Verbal Rating Scale (VRS. The laser therapy was scheduled as once a day regime for three consecutive postoperative days (PODs starting on POD 1, 30 min following tracheal extubation. The subsequent laser applications were also scheduled at the same time of the day as on day 1 if VRS was ≥5. 10 W Class IV laser was applied over 150 cm 2 sternal wound area for 150 s. VRS was used to assess pain severity and was recorded for statistical analysis using Friedman Test. Results: The mean (standard deviation [SD] VRS of all the 100 patients just before application of the first dose of laser was 7.31 (0.94 while on MMT; the same fell to 4.0 (1.279 and 3.40 (2.697 at 1 h and 24 h respectively following first dose of laser. The change of VRS over first 24 h among all the 100 patients was statistically significant (P = 0.000. Laser was re-applied in 40 patients whose VRS was ≥5 (mean [SD] - 6.38 [0.868] at 24 th h. After receiving the 2 nd dose of laser the VRS scores fell significantly (P = 0.000 and became 0 at 54 th h. No patients required 3 rd dose of the laser. No patient

  6. Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial.

    Science.gov (United States)

    Lind, Marcus; Polonsky, William; Hirsch, Irl B; Heise, Tim; Bolinder, Jan; Dahlqvist, Sofia; Schwarz, Erik; Ólafsdóttir, Arndís Finna; Frid, Anders; Wedel, Hans; Ahlén, Elsa; Nyström, Thomas; Hellman, Jarl

    2017-01-24

    The majority of individuals with type 1 diabetes do not meet recommended glycemic targets. To evaluate the effects of continuous glucose monitoring in adults with type 1 diabetes treated with multiple daily insulin injections. Open-label crossover randomized clinical trial conducted in 15 diabetes outpatient clinics in Sweden between February 24, 2014, and June 1, 2016 that included 161 individuals with type 1 diabetes and hemoglobin A1c (HbA1c) of at least 7.5% (58 mmol/mol) treated with multiple daily insulin injections. Participants were randomized to receive treatment using a continuous glucose monitoring system or conventional treatment for 26 weeks, separated by a washout period of 17 weeks. Difference in HbA1c between weeks 26 and 69 for the 2 treatments. Adverse events including severe hypoglycemia were also studied. Among 161 randomized participants, mean age was 43.7 years, 45.3% were women, and mean HbA1c was 8.6% (70 mmol/mol). A total of 142 participants had follow-up data in both treatment periods. Mean HbA1c was 7.92% (63 mmol/mol) during continuous glucose monitoring use and 8.35% (68 mmol/mol) during conventional treatment (mean difference, -0.43% [95% CI, -0.57% to -0.29%] or -4.7 [-6.3 to -3.1 mmol/mol]; P < .001). Of 19 secondary end points comprising psychosocial and various glycemic measures, 6 met the hierarchical testing criteria of statistical significance, favoring continuous glucose monitoring compared with conventional treatment. Five patients in the conventional treatment group and 1 patient in the continuous glucose monitoring group had severe hypoglycemia. During washout when patients used conventional therapy, 7 patients had severe hypoglycemia. Among patients with inadequately controlled type 1 diabetes treated with multiple daily insulin injections, the use of continuous glucose monitoring compared with conventional treatment for 26 weeks resulted in lower HbA1c. Further research is needed to assess clinical outcomes and longer

  7. Glycemia, Hypoglycemia, and Costs of Simultaneous Islet-Kidney or Islet After Kidney Transplantation Versus Intensive Insulin Therapy and Waiting List for Islet Transplantation.

    Science.gov (United States)

    Gerber, Philipp A; Locher, Rebecca; Zuellig, Richard A; Tschopp, Oliver; Ajdler-Schaeffler, Evelyne; Kron, Philipp; Oberkofler, Christian; Brändle, Michael; Spinas, Giatgen A; Lehmann, Roger

    2015-10-01

    Long-term data of patients with type 1 diabetes mellitus (T1D) after simultaneous islet-kidney (SIK) or islet-after-kidney transplantation (IAK) are rare and have never been compared to intensified insulin therapy (IIT). Twenty-two patients with T1D and end-stage renal failure undergoing islet transplantation were compared to 70 patients matched for age and diabetes duration treated with IIT and to 13 patients with kidney transplantation alone or simultaneous pancreas-kidney after loss of pancreas function (waiting list for IAK [WLI]). Glycemic control, severe hypoglycemia, insulin requirement, and direct medical costs were analyzed. Glycated hemoglobin decreased significantly from 8.2 ± 1.5 to 6.7 ± 0.9% at the end of follow-up (mean 7.2 ± 2.5 years) in the SIK/IAK and remained constant in IIT (7.8 ± 1.0% and 7.6 ± 1.0) and WLI (7.8 ± 0.8 and 7.9 ± 1.0%). Daily insulin requirement decreased from 0.53 ± 0.15 to 0.29 ± 0.26 U/kg and remained constant in IIT (0.59 ± 0.19 and 0.58 ± 0.23 U/kg) and in WLI (0.76 ± 0.28 and 0.73 ± 0.11 U/kg). Severe hypoglycemia dropped in SIK/IAK from 4.5 ± 9.7 to 0.3 ± 0.7/patient-year and remained constant in IIT (0.1 ± 0.7 and 0.2 ± 0.8/patient-year). Detailed cost analysis revealed US $57,525 of additional cost for islet transplantation 5 years after transplantation. Based on a 5- and 10-year analysis, cost neutrality is assumed to be achieved 15 years after transplantation. This long-term cohort with more than 7 years of follow-up shows that glycemic control in patients with T1D after SIK/IAK transplantation improved, and the rate of severe hypoglycemia decreased significantly as compared to control groups. Cost analysis revealed that islet transplantation is estimated to be cost neutral at 15 years after transplantation.

  8. New Insulin Delivery Recommendations.

    Science.gov (United States)

    Frid, Anders H; Kreugel, Gillian; Grassi, Giorgio; Halimi, Serge; Hicks, Debbie; Hirsch, Laurence J; Smith, Mike J; Wellhoener, Regine; Bode, Bruce W; Hirsch, Irl B; Kalra, Sanjay; Ji, Linong; Strauss, Kenneth W

    2016-09-01

    Many primary care professionals manage injection or infusion therapies in patients with diabetes. Few published guidelines have been available to help such professionals and their patients manage these therapies. Herein, we present new, practical, and comprehensive recommendations for diabetes injections and infusions. These recommendations were informed by a large international survey of current practice and were written and vetted by 183 diabetes experts from 54 countries at the Forum for Injection Technique and Therapy: Expert Recommendations (FITTER) workshop held in Rome, Italy, in 2015. Recommendations are organized around the themes of anatomy, physiology, pathology, psychology, and technology. Key among the recommendations are that the shortest needles (currently the 4-mm pen and 6-mm syringe needles) are safe, effective, and less painful and should be the first-line choice in all patient categories; intramuscular injections should be avoided, especially with long-acting insulins, because severe hypoglycemia may result; lipohypertrophy is a frequent complication of therapy that distorts insulin absorption, and, therefore, injections and infusions should not be given into these lesions and correct site rotation will help prevent them; effective long-term therapy with insulin is critically dependent on addressing psychological hurdles upstream, even before insulin has been started; inappropriate disposal of used sharps poses a risk of infection with blood-borne pathogens; and mitigation is possible with proper training, effective disposal strategies, and the use of safety devices. Adherence to these new recommendations should lead to more effective therapies, improved outcomes, and lower costs for patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  9. ASPIRE In-Home: rationale, design, and methods of a study to evaluate the safety and efficacy of automatic insulin suspension for nocturnal hypoglycemia.

    Science.gov (United States)

    Klonoff, David C; Bergenstal, Richard M; Garg, Satish K; Bode, Bruce W; Meredith, Melissa; Slover, Robert H; Ahmann, Andrew; Welsh, John B; Lee, Scott W

    2013-07-01

    Nocturnal hypoglycemia is a barrier to therapy intensification efforts in diabetes. The Paradigm® Veo™ system may mitigate nocturnal hypoglycemia by automatically suspending insulin when a prespecified sensor glucose threshold is reached. ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) In-Home (NCT01497938) was a multicenter, randomized, parallel, adaptive study of subjects with type 1 diabetes. The control arm used sensor-augmented pump therapy. The treatment arm used sensor-augmented pump therapy with threshold suspend, which automatically suspends the insulin pump in response to a sensor glucose value at or below a prespecified threshold. To be randomized, subjects had to have demonstrated ≥2 episodes of nocturnal hypoglycemia, defined as >20 consecutive minutes of sensor glucose values ≤65 mg/dl starting between 10:00 PM and 8:00 AM in the 2-week run-in phase. The 3-month study phase evaluated safety by comparing changes in glycated hemoglobin (A1C) values and evaluated efficacy by comparing the mean area under the glucose concentration time curves for nocturnal hypoglycemia events in the two groups. Other outcomes included the rate of nocturnal hypoglycemia events and the distribution of sensor glucose values. Data from the ASPIRE In-Home study should provide evidence on the safety of the threshold suspend feature with respect to A1C and its efficacy with respect to severity and duration of nocturnal hypoglycemia when used at home over a 3-month period. © 2013 Diabetes Technology Society.

  10. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  11. Effects of insulin-like growth factor-I deficiency and replacement therapy on the hematopoietic system in patients with Laron syndrome (primary growth hormone insensitivity).

    Science.gov (United States)

    Sivan, Bezalel; Lilos, Pearl; Laron, Zvi

    2003-01-01

    Primary insulin-like growth factor-I (IGF-I) deficiencies, such as in Laron syndrome (LS), are a unique model in man to study the consequences resulting from defects in growth hormone (GH) signal transmission. To assess retrospectively the effect of IGF-I deficiency and its therapy on the various cells of the hematopoietic system as reflected by peripheral blood counts. Two groups of patients were studied. The first group consisted of 11 untreated patients with LS, seven males and four females, who were followed from childhood into adult age. Average age at the time of data analysis was 45.4 +/- 9.6 years. The second group included ten children with LS, six males and four females, who received IGF-I replacement therapy for an average period of 6 years, ranging in age from 0.9-11 years. The mean age at initiation of therapy was 6.9 +/- 4.28 years. Only the seven children treated for 5 years or more were included in the analysis. Data on blood counts were collected from the patients' charts. Blood samples were drawn at baseline, weekly during the first month, once a month during the first year, and once every 3 months thereafter. Statistical analysis of the change over time was performed using repeated measures ANOVA. Children with LS had red cell indices in the lower normal range and an elevated monocyte count. A statistically significant rise in red blood cell (RBC) indices was seen in children during IGF-I therapy: RBC rose from 4.66 x 10(6)/ml to 4.93 x 10(6)/ml (p = 0.011); hemoglobin from 11.55 g/dl to 13.01 g/dl (p syndrome, confirms that IGF-I has a strong stimulatory effect on erythropoiesis. In addition, IGF-I therapy had a reducing effect on monocytes and platelets, an effect not previously described. The mechanism by which IGF-I mediates these effects needs further elucidation.

  12. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  13. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  14. Co-infusion of autologous adipose tissue derived insulin-secreting mesenchymal stem cells and bone marrow derived hematopoietic stem cells: Viable therapy for type III.C. a diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Umang G Thakkar

    2014-12-01

    Full Text Available Transition from acute pancreatitis to insulin-dependent diabetes mellitus (IDDM is a rare manifestation of primary hyperparathyroidism caused by parathyroid adenoma because of impaired glucose tolerance and suppresses insulin secretion. We report the case of a 26-year-old male with pancreatic diabetes caused by parathyroid adenoma induced chronic pancreatitis. He had serum C-peptide 0.12 ng/ml, glutamic acid decarboxylase antibody 5.0 IU/ml, and glycosylated hemoglobin (HbA1C 8.9%, and required 72 IU/day of biphasic-isophane insulin injection for uncontrolled hyperglycemia. We treated him with his own adipose tissue derived insulin-secreting mesenchymal stem-cells (IS-ADMSC along with his bone marrow derived hematopoietic stem cells (BM-HSC. Autologous IS-ADMSC + BM-HSC were infused into subcutaneous tissue, portal and thymic circulation without any conditioning. Over a follow-up of 27 months, the patient is maintaining fasting and postprandial blood sugar levels of 132 and 165 mg/dl, respectively, with HbA1C 6.8% and requiring 36 IU/day of biphasic-isophane insulin. Co-infusion of IS-ADMSC + BM-HSC offers a safe and viable therapy for type III.C.a Diabetes Mellitus.

  15. Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study.

    Science.gov (United States)

    Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J

    2017-07-31

    Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform

  16. Insulin analogues with improved absorption characteristics.

    Science.gov (United States)

    Brange, J; Hansen, J F; Langkjaer, L; Markussen, J; Ribel, U; Sørensen, A R

    1992-01-01

    The insulin preparations available today are not ideal for therapy as s.c. injection does not provide a physiological insulin profile. With the aim to improve the absorption properties recombinant DNA technology has been utilized to design novel insulin molecules with changed physico-chemical characteristics and hence altered subcutaneous absorption kinetics. Soluble, long-acting human insulin analogues in which the isoelectric point has been increased from 5.4 to approx. 7 are absorbed very slowly, providing a more constant basal insulin delivery with lower day-to-day variation than present protracted preparations. In addition they have better storage stability. Rapid-acting human insulin analogues with largely reduced self-association are absorbed substantially faster from subcutaneous tissue than current regular insulin and thus are better suited for bolus injection. The absorption kinetics of these analogues have been able to explain the mechanism behind the dose effect on insulin absorption rate.

  17. Exogenous insulin antibody syndrome (EIAS): a clinical syndrome associated with insulin antibodies induced by exogenous insulin in diabetic patients.

    Science.gov (United States)

    Hu, Xiaolei; Chen, Fengling

    2018-01-01

    Insulin has been used for diabetes therapy and has achieved significant therapeutic effect. In recent years, the use of purified and recombinant human insulin preparations has markedly reduced, but not completely suppressed, the incidence of insulin antibodies (IAs). IAs induced by exogenous insulin in diabetic patients is associated with clinical events, which is named exogenous insulin antibody syndrome (EIAS). The present review is based on our research and summarizes the characterization of IAs, the factors affecting IA development, the clinical significance of IAs and the treatments for EIAS. © 2018 The authors.

  18. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  19. Application of polymeric nanoparticles and micelles in insulin oral delivery

    Directory of Open Access Journals (Sweden)

    Milind Sadashiv Alai

    2015-09-01

    Full Text Available Diabetes mellitus is an endocrine disease in which the pancreas does not produce sufficient insulin or the body cannot effectively use the insulin it produces. Insulin therapy has been the best choice for the clinical management of diabetes mellitus. The current insulin therapy is via subcutaneous injection, which often fails to mimic the glucose homeostasis that occurs in normal individuals. This provokes numerous attempts to develop a safe and effective noninvasive route for insulin delivery. Oral delivery is the most convenient administration route. However, insulin cannot be well absorbed orally because of its rapid enzymatic degradation in the gastrointestinal tract. Therefore, nanoparticulate carriers such as polymeric nanoparticles and micelles are employed for the oral delivery of insulin. These nanocarriers protect insulin from degradation and facilitate insulin uptake via a transcellular and/or paracellular pathway. This review article focuses on the application of nanoparticles and micelles in insulin oral delivery. The recent advances in this topic are also reviewed.

  20. Acid and non-acid reflux in patients refractory to proton pump inhibitor therapy: is gastroparesis a factor?

    Science.gov (United States)

    Tavakkoli, Anna; Sayed, Bisma A; Talley, Nicholas J; Moshiree, Baharak

    2013-10-07

    To determine whether an increased number and duration of non-acid reflux events as measured using the multichannel intraluminal impedance pH (MII-pH) is linked to gastroparesis (GP). A case control study was conducted in which 42 patients undergoing clinical evaluation for continued symptoms of gastroesophageal reflux disease (both typical and atypical symptoms) despite acid suppression therapy. MII-pH technology was used over 24 h to detect reflux episodes and record patients' symptoms. Parameters evaluated in patients with documented GP and controls without GP by scintigraphy included total, upright, and supine number of acid and non-acid reflux episodes (pH 4, respectively), the duration of acid and non-acid reflux in a 24-h period, and the number of reflux episodes lasting longer than 5 min. No statistical difference was seen between the patients with GP and controls with respect to the total number or duration of acid reflux events, total number and duration of non-acid reflux events or the duration of longest reflux episodes. The number of non-acid reflux episodes with a pH > 7 was higher in subjects with GP than in controls. In addition, acid reflux episodes were more prolonged (lasting longer than 5 min) in the GP patients than in controls; however, these values did not reach statistical significance. Thirty-five patients had recorded symptoms during the 24 h study and of the 35 subjects, only 9% (n = 3) had a positive symptom association probability (SAP) for acid/non-acid reflux and 91% had a negative SAP. The evaluation of patients with a documented history of GP did not show an association between GP and more frequent episodes of non-acid reflux based on MII-pH testing.

  1. Limited Effect of Rebamipide in Addition to Proton Pump Inhibitor (PPI) in the Treatment of Post-Endoscopic Submucosal Dissection Gastric Ulcers: A Randomized Controlled Trial Comparing PPI Plus Rebamipide Combination Therapy with PPI Monotherapy

    OpenAIRE

    Nakamura, Kazuhiko; Ihara, Eikichi; Akiho, Hirotada; Akahoshi, Kazuya; Harada, Naohiko; Ochiai, Toshiaki; Nakamura, Norimoto; Ogino, Haruei; Iwasa, Tsutomu; Aso, Akira; Iboshi, Yoichiro; Takayanagi, Ryoichi

    2016-01-01

    Background/Aims The ability of endoscopic submucosal dissection (ESD) to resect large early gastric cancers (EGCs) results in the need to treat large artificial gastric ulcers. This study assessed whether the combination therapy of rebamipide plus a proton pump inhibitor (PPI) offered benefits over PPI monotherapy. Methods In this prospective, randomized, multicenter, open-label, and comparative study, patients who had undergone ESD for EGC or gastric adenoma were randomized into groups recei...

  2. Macronutrient Composition and Management of Non-Insulin-Dependent Diabetes Mellitus (NIDDM): A New Paradigm for Individualized Nutritional Therapy in Diabetes Patients.

    Science.gov (United States)

    Koloverou, Efi; Panagiotakos, Demosthenes B

    2016-01-01

    Medical nutrition therapy constitutes an important lifestyle intervention in diabetes management. Several nutrition patterns have been effective in improving diabetes control, but there has been a debate about the optimal macronutrient composition in diabetes meal planning. For many years, the recommended diets for persons with and without diabetes were similar, i.e. heart-healthy and low in fat. For almost three decades, carbohydrates have been lauded, lipids demonized, and proteins considered of little importance. However, in the past few years, this concept has been questioned and reassessed. Modern nutritional recommendations for people with diabetes are headed towards individualization, but lack specific guidelines. Nutritional algorithms may help nutritionists in diabetes meal planning. This review aims to discuss: 1) the effects of the three major macronutrients (carbohydrates, proteins, and lipids) on glucose levels, 2) current recommendations for macronutrient intake for people with diabetes, and 3) specific parameters that need to be taken into consideration when determining the macronutrient composition for a person with diabetes, for example body mass index, degree of insulin resistance, HbA1c value, and lipid profile (especially triglycerides and HDL cholesterol). These aspects are analyzed in the context of the results of recent studies, especially randomized controlled trials (RCTs). Finally, we introduce an individualized nutritional concept that proposes carbohydrate over lipid restriction, substitution of SFAs with MUFAs and PUFAs, and adequate intake of dietary fiber, which are key factors in optimizing diabetes management.

  3. Comparison of the Effects of Continuous Subcutaneous Insulin Infusion and Add-On Therapy with Sitagliptin in Patients with Newly Diagnosed Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Heng Wan

    2016-01-01

    Full Text Available To identify a new regimen to optimize treatment for patients with newly diagnosed type 2 diabetes (T2DM by short-term continuous subcutaneous insulin infusion (CSII alone. Methods. 60 patients with newly diagnosed T2DM were randomized into two groups (n=30 each and treated for 2 weeks with CSII alone (CSII group or with CSII plus sitagliptin (CSII + Sig group. The glycemic variability of the patients was measured using a continuous glucose monitoring system (CGMS for the last 72 hours. A standard meal test was performed before and after the interventions, and the levels of glycated albumin, fasting glucose, fasting C-peptide, postprandial 2 h blood glucose, and postprandial 2 h C-peptide were examined. Results. Compared with the CSII group, the indicators of glycemic variability, such as the mean amplitude of glycemic excursion (MAGE and the standard deviation of blood glucose (SDBG, were decreased significantly in the CSII + Sig group. The changes before and after treatment in the C-peptide reactivity index (ΔCPI and the secretory unit of islet in transplantation index (ΔSUIT indicated a significant improvement in the CSII + Sig group. Conclusions. Add-on therapy with sitagliptin may be an optimized treatment for patients with newly diagnosed T2DM compared with short-term CSII alone.

  4. Review and Update of Insulin Dependent Diabetes Mellitus

    OpenAIRE

    Gorrell, Jennifer Justice; Williams, Jennifer Schoelles; Powell, Paula

    2003-01-01

    The purpose of this article is to provide the health care practitioner with a comprehensive review of the pathophysiology and treatment of Type 1 Diabetes Mellitus. Traditionally, insulin has been administered via an insulin syringe. In the recent past, diabetes research has focused on developing more convenient insulin delivery devices and longer acting insulin's in hopes of increasing compliance with insulin therapy and improving the management of Type 1 diabetes in both children and adults...

  5. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  6. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  7. Mechanisms of insulin resistance in obesity

    Science.gov (United States)

    Ye, Jianping

    2014-01-01

    Obesity increases the risk for type 2 diabetes through induction of insulin resistance. Treatment of type 2 diabetes has been limited by little translational knowledge of insulin resistance although there have been several well-documented hypotheses for insulin resistance. In those hypotheses, inflammation, mitochondrial dysfunction, hyperinsulinemia and lipotoxicity have been the major concepts and have received a lot of attention. Oxidative stress, endoplasmic reticulum (ER) stress, genetic background, aging, fatty liver, hypoxia and lipodystrophy are active subjects in the study of these concepts. However, none of those concepts or views has led to an effective therapy for type 2 diabetes. The reason is that there has been no consensus for a unifying mechanism of insulin resistance. In this review article, literature is critically analyzed and reinterpreted for a new energy-based concept of insulin resistance, in which insulin resistance is a result of energy surplus in cells. The energy surplus signal is mediated by ATP and sensed by adenosine monophosphate-activated protein kinase (AMPK) signaling pathway. Decreasing ATP level by suppression of production or stimulation of utilization is a promising approach in the treatment of insulin resistance. In support, many of existing insulin sensitizing medicines inhibit ATP production in mitochondria. The effective therapies such as weight loss, exercise, and caloric restriction all reduce ATP in insulin sensitive cells. This new concept provides a unifying cellular and molecular mechanism of insulin resistance in obesity, which may apply to insulin resistance in aging and lipodystrophy. PMID:23471659

  8. Two Cases of Allergy to Insulin in Gestational Diabetes

    Directory of Open Access Journals (Sweden)

    Gi Jun Kim

    2015-09-01

    Full Text Available Allergic reaction to insulin is uncommon since the introduction of human recombinant insulin preparations and is more rare in pregnant than non-pregnant females due to altered immune reaction during pregnancy. Herein, we report two cases of allergic reaction to insulin in gestational diabetes that were successfully managed. One case was a 33-year-old female using isophane-neutral protamine Hagedorn human insulin and insulin lispro. She experienced dyspnea, cough, urticaria and itching sensation at the sites of insulin injection immediately after insulin administration. We discontinued insulin therapy and started oral hypoglycemic agents with metformin and glibenclamide. The other case was a 32-year-old female using insulin lispro and insulin detemer. She experienced pruritus and burning sensation and multiple nodules at the sites of insulin injection. We changed the insulin from insulin lispro to insulin aspart. Assessments including immunoglobulin E (IgE, IgG, eosinophil, insulin antibody level and skin biopsy were performed. In the two cases, the symptoms were resolved after changing the insulin to oral agents or other insulin preparations. We report two cases of allergic reaction to human insulin in gestational diabetes due to its rarity.

  9. Conflicting results between randomized trials and observational studies on the impact of proton pump inhibitors on cardiovascular events when coadministered with dual antiplatelet therapy: systematic review.

    Science.gov (United States)

    Melloni, Chiara; Washam, Jeffrey B; Jones, W Schuyler; Halim, Sharif A; Hasselblad, Victor; Mayer, Stephanie B; Heidenfelder, Brooke L; Dolor, Rowena J

    2015-01-01

    Discordant results have been reported on the effects of concomitant use of proton pump inhibitors (PPIs) and dual antiplatelet therapy (DAPT) for cardiovascular outcomes. We conducted a systematic review comparing the effectiveness and safety of concomitant use of PPIs and DAPT in the postdischarge treatment of unstable angina/non-ST-segment-elevation myocardial infarction patients. We searched for clinical studies in MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews, from 1995 to 2012. Reviewers screened and extracted data, assessed applicability and quality, and graded the strength of evidence. We performed meta-analyses of direct comparisons when outcomes and follow-up periods were comparable. Thirty-five studies were eligible. Five (4 randomized controlled trials and 1 observational) assessed the effect of omeprazole when added to DAPT; the other 30 (observational) assessed the effect of PPIs as a class when compared with no PPIs. Random-effects meta-analyses of the studies assessing PPIs as a class consistently reported higher event rates in patients receiving PPIs for various clinical outcomes at 1 year (composite ischemic end points, all-cause mortality, nonfatal MI, stroke, revascularization, and stent thrombosis). However, the results from randomized controlled trials evaluating omeprazole compared with placebo showed no difference in ischemic outcomes, despite a reduction in upper gastrointestinal bleeding with omeprazole. Large, well-conducted observational studies of PPIs and randomized controlled trials of omeprazole seem to provide conflicting results for the effect of PPIs on cardiovascular outcomes when coadministered with DAPT. Prospective trials that directly compare pharmacodynamic parameters and clinical events among specific PPI agents in patients with unstable angina/non-ST-segment-elevation myocardial infarction treated with DAPT are warranted. © 2015 American Heart Association, Inc.

  10. Connections between nutritional status and proton pump inhibitor therapy in patients scheduled for cardiovascular rehabilitation after treatment for ischaemic and valvular heart disease.

    Science.gov (United States)

    Boban, Marko; Persic, Viktor; Petricevic, Mate; Biocina, Bojan; Sipic, Tomislav; Pehar-Pejcnovic, Vesna; Balen, Sanja; Zulj, Marinko; Vcev, Aleksandar

    Multiple and yet uncertain connections exist between cardiovascular diseases and the nutritional status of patients, particularly in relation to cardiovascular treatments. Proton pump inhibitors (PPI) are among the most commonly used group of drugs. To analyse utilisation of PPI in association with nutritional risk of patients scheduled for rehabilitation after treatment for ischaemic and valvular heart disease. Retrospective analyses on a consecutive sample of patients, which included drug utilisation of PPI and nutritional risk screening, using a standardised NRS-2002 tool. The patients (n = 536) were divided into groups based on previous cardiovascular treatments and use of PPI. Nearly half of the patients (244, 46.1%) had PPI in their chronic therapy despite the clinically negligible prevalence of conditions that are their fundamental indications. The odds for using PPI in patients with increased nutritional risk, estimated by logistic regression, were 3.34 (95% confidence intervals [CI] 2.26-4.94), p 3: positive likelihood-ratio (LR) 2.35 (95% CI 2.10-2.60); negative LR 0.46 (95% CI 0.4-0.6); area under the curve (AUC) 0.720; p 6.36% (positive LR 2.22 [95% CI 2.00-2.50]; negative LR 0.41 [95% CI 0.30-0.50]; AUC 0.707; p < 0.001). Utilisation of PPI was found to be of relatively high prevalence and significantly associated with parameters of nutritional risk screening. Furthermore, it was in correlation with the age of patients and the existence of chronic kidney disease, which are well-established predispositions for poor nutritional status. Nutritional risk seems to be additionally negatively challenged by utilisation of PPI due to gastric malabsorption and anaemia.

  11. Intranasal Insulin Restores Metabolic Parameters and Insulin Sensitivity in Rats with Metabolic Syndrome.

    Science.gov (United States)

    Derkach, K V; Ivantsov, A O; Chistyakova, O V; Sukhov, I B; Buzanakov, D M; Kulikova, A A; Shpakov, A O

    2017-06-01

    We studied the effect of 10-week treatment with intranasal insulin (0.5 IU/day) on glucose tolerance, glucose utilization, lipid metabolism, functions of pancreatic β cells, and insulin system in the liver of rats with cafeteria diet-induced metabolic syndrome. The therapy reduced body weight and blood levels of insulin, triglycerides, and atherogenic cholesterol that are typically increased in metabolic syndrome, normalized glucose tolerance and its utilization, and increased activity of insulin signaling system in the liver, thus reducing insulin resistance. The therapy did not affect the number of pancreatic islets and β cells. The study demonstrates prospects of using intranasal insulin for correction of metabolic parameters and reduction of insulin resistance in metabolic syndrome.

  12. Assessment of use of specific features of subcutaneous insulin infusion systems and their relationship to metabolic control in patients with type 1 diabetes.

    Science.gov (United States)

    Quirós, Carmen; Patrascioiu, Ioana; Giménez, Marga; Vinagre, Irene; Vidal, Mercè; Jansà, Margarita; Conget, Ignacio

    2014-01-01

    Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c 7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  13. Insulin dependence and pancreatic enzyme replacement therapy are independent prognostic factors for long-term survival after operation for chronic pancreatitis.

    Science.gov (United States)

    Winny, Markus; Paroglou, Vagia; Bektas, Hüseyin; Kaltenborn, Alexander; Reichert, Benedikt; Zachau, Lea; Kleine, Moritz; Klempnauer, Jürgen; Schrem, Harald

    2014-02-01

    This retrospective, single-center, observational study on postoperative long-term results aims to define yet unknown factors for long-term outcome after operation for chronic pancreatitis. We analyzed 147 consecutive patients operated for chronic pancreatitis from 2000 to 2011. Mean follow-up was 5.3 years (range, 1 month to 12.7 years). Complete long-term survival data were provided by the German citizen registration authorities for all patients. A quality-of-life questionnaire was sent to surviving patients after a mean follow-up of 5.7 years. Surgical principles were resection (n = 86; 59%), decompression (n = 29; 20%), and hybrid procedures (n = 32; 21%). No significant influences of different surgical principles and operative procedures on survival, long-term quality of life and pain control could be detected. Overall 30-day mortality was 2.7%, 1-year survival 95.9%, and 3-year survival 90.8%. Multivariate Cox regression analysis revealed that only postoperative insulin dependence at the time of hospital discharge (P = .027; Exp(B) = 2.111; 95% confidence interval [CI], 1.089-4.090) and the absence of pancreas enzyme replacement therapy at the time of hospital discharge (P = .039; Exp(B) = 2.102; 95% CI, 1.037-4.262) were significant, independent risk factors for survival with significant hazard ratios for long-term survival. Long-term improvement in quality of life was reported by 55 of 76 long-term survivors (73%). Pancreatic enzyme replacement should be standard treatment after surgery for chronic pancreatitis at the time of hospital discharge, even when no clinical signs of exocrine pancreatic failure exist. This study underlines the potential importance of early operative intervention in chronic pancreatitis before irreversible endocrine dysfunction is present. Copyright © 2014 Mosby, Inc. All rights reserved.

  14. Human beta-cell precursors mature into functional insulin-producing cells in an immunoisolation device: implications for diabetes cell therapies.

    Science.gov (United States)

    Lee, Seung-Hee; Hao, Ergeng; Savinov, Alexei Y; Geron, Ifat; Strongin, Alex Y; Itkin-Ansari, Pamela

    2009-04-15

    Islet transplantation is limited by the need for chronic immunosuppression and the paucity of donor tissue. As new sources of human beta-cells are developed (e.g., stem cell-derived tissue), transplanting them in a durable device could obviate the need for immunosuppression, while also protecting the patient from any risk of tumorigenicity. Here, we studied (1) the survival and function of encapsulated human beta-cells and their progenitors and (2) the engraftment of encapsulated murine beta-cells in allo- and autoimmune settings. Human islets and human fetal pancreatic islet-like cell clusters were encapsulated in polytetrafluorethylene devices (TheraCyte) and transplanted into immunodeficient mice. Graft survival and function was measured by immunohistochemistry, circulating human C-peptide levels, and blood glucose levels. Bioluminescent imaging was used to monitor encapsulated neonatal murine islets. Encapsulated human islet-like cell clusters survived, replicated, and acquired a level of glucose responsive insulin secretion sufficient to ameliorate hyperglycemia in diabetic mice. Bioluminescent imaging of encapsulated murine neonatal islets revealed a dynamic process of cell death followed by regrowth, resulting in robust long-term allograft survival. Further, in the non-obese diabetic (NOD) mouse model of type I diabetes, encapsulated primary beta-cells ameliorated diabetes without stimulating a detectable T-cell response. We demonstrate for the first time that human beta-cells function is compatible with encapsulation in a durable, immunoprotective device. Moreover, our study suggests that encapsulation of beta-cells before terminal differentiation will be a successful approach for new cell-based therapies for diabetes, such as those derived from stem cells.

  15. Human β-cell Precursors Mature Into Functional Insulin-producing Cells in an Immunoisolation Device: Implications for Diabetes Cell Therapies

    Science.gov (United States)

    Lee, Seung-Hee; Hao, Ergeng; Savinov, Alexei Y.; Geron, Ifat; Strongin, Alex Y.; Itkin-Ansari, Pamela

    2009-01-01

    Background Islet transplantation is limited by the need for chronic immunosuppression and the paucity of donor tissue. As new sources of human β-cells are developed (e.g., stem cell-derived tissue), transplanting them in a durable device could obviate the need for immunosuppression, while also protecting the patient from any risk of tumorigenicity. Here, we studied (1) the survival and function of encapsulated human β-cells and their progenitors and (2) the engraftment of encapsulated murine β-cells in allo- and autoimmune settings. Methods Human islets and human fetal pancreatic islet-like cell clusters were encapsulated in polytetrafluorethylene devices (TheraCyte) and transplanted into immunodeficient mice. Graft survival and function was measured by immunohistochemistry, circulating human C-peptide levels, and blood glucose levels. Bioluminescent imaging was used to monitor encapsulated neonatal murine islets. Results Encapsulated human islet-like cell clusters survived, replicated, and acquired a level of glucose responsive insulin secretion sufficient to ameliorate hyperglycemia in diabetic mice. Bioluminescent imaging of encapsulated murine neonatal islets revealed a dynamic process of cell death followed by regrowth, resulting in robust long-term allograft survival. Further, in the non-obese diabetic (NOD) mouse model of type I diabetes, encapsulated primary β-cells ameliorated diabetes without stimulating a detectable T-cell response. Conclusions We demonstrate for the first time that human β-cells function is compatible with encapsulation in a durable, immunoprotective device. Moreover, our study suggests that encapsulation of β-cells before terminal differentiation will be a successful approach for new cell-based therapies for diabetes, such as those derived from stem cells. PMID:19352116

  16. Targeting insulin resistance in type 2 diabetes via immune modulation of cord blood-derived multipotent stem cells (CB-SCs) in stem cell educator therapy: phase I/II clinical trial.

    Science.gov (United States)

    Zhao, Yong; Jiang, Zhaoshun; Zhao, Tingbao; Ye, Mingliang; Hu, Chengjin; Zhou, Huimin; Yin, Zhaohui; Chen, Yana; Zhang, Ye; Wang, Shanfeng; Shen, Jie; Thaker, Hatim; Jain, Summit; Li, Yunxiang; Diao, Yalin; Chen, Yingjian; Sun, Xiaoming; Fisk, Mary Beth; Li, Heng

    2013-07-09

    The prevalence of type 2 diabetes (T2D) is increasing worldwide and creating a significant burden on health systems, highlighting the need for the development of innovative therapeutic approaches to overcome immune dysfunction, which is likely a key factor in the development of insulin resistance in T2D. It suggests that immune modulation may be a useful tool in treating the disease. In an open-label, phase 1/phase 2 study, patients (N=36) with long-standing T2D were divided into three groups (Group A, oral medications, n=18; Group B, oral medications+insulin injections, n=11; Group C having impaired β-cell function with oral medications+insulin injections, n=7). All patients received one treatment with the Stem Cell Educator therapy in which a patient's blood is circulated through a closed-loop system that separates mononuclear cells from the whole blood, briefly co-cultures them with adherent cord blood-derived multipotent stem cells (CB-SCs), and returns the educated autologous cells to the patient's circulation. Clinical findings indicate that T2D patients achieve improved metabolic control and reduced inflammation markers after receiving Stem Cell Educator therapy. Median glycated hemoglobin (HbA1C) in Group A and B was significantly reduced from 8.61%±1.12 at baseline to 7.25%±0.58 at 12 weeks (P=2.62E-06), and 7.33%±1.02 at one year post-treatment (P=0.0002). Homeostasis model assessment (HOMA) of insulin resistance (HOMA-IR) demonstrated that insulin sensitivity was improved post-treatment. Notably, the islet beta-cell function in Group C subjects was markedly recovered, as demonstrated by the restoration of C-peptide levels. Mechanistic studies revealed that Stem Cell Educator therapy reverses immune dysfunctions through immune modulation on monocytes and balancing Th1/Th2/Th3 cytokine production. Clinical data from the current phase 1/phase 2 study demonstrate that Stem Cell Educator therapy is a safe approach that produces lasting improvement in

  17. Update on insulin treatment for dogs and cats: insulin dosing pens and more

    Directory of Open Access Journals (Sweden)

    Thompson A

    2015-04-01

    Full Text Available Ann Thompson,1 Patty Lathan,2 Linda Fleeman3 1School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia; 2College of Veterinary Medicine Mississippi State University, Starkville, MS, USA; 3Animal Diabetes Australia, Melbourne, VIC, Australia Abstract: Insulin therapy is still the primary therapy for all diabetic dogs and cats. Several insulin options are available for each species, including veterinary registered products and human insulin preparations. The insulin chosen depends on the individual patient's requirements. Intermediate-acting insulin is usually the first choice for dogs, and longer-acting insulin is the first choice for cats. Once the insulin type is chosen, the best method of insulin administration should be considered. Traditionally, insulin vials and syringes have been used, but insulin pen devices have recently entered the veterinary market. Pens have different handling requirements when compared with standard insulin vials including: storage out of the refrigerator for some insulin preparations once pen cartridges are in use; priming of the pen to ensure a full dose of insulin is administered; and holding the pen device in place for several seconds during the injection. Many different types of pen devices are available, with features such as half-unit dosing, large dials for visually impaired people, and memory that can display the last time and dose of insulin administered. Insulin pens come in both reusable and disposable options. Pens have several benefits over syringes, including improved dose accuracy, especially for low insulin doses. Keywords: diabetes, mellitus, canine, feline, NPH, glargine, porcine lente

  18. Insulin analogs with improved pharmacokinetic profiles.

    Science.gov (United States)

    Brange; Vølund

    1999-02-01

    The aim of insulin replacement therapy is to normalize blood glucose in order to reduce the complications of diabetes. The pharmacokinetics of the traditional insulin preparations, however, do not match the profiles of physiological insulin secretion. The introduction of the rDNA technology 20 years ago opened new ways to create insulin analogs with altered properties. Fast-acting analogs are based on the idea that an insulin with less tendency to self-association than human insulin would be more readily absorbed into the systemic circulation. Protracted-acting analogs have been created to mimic the slow, steady rate of insulin secretion in the fasting state. The present paper provides a historical review of the efforts to change the physicochemical and pharmacological properties of insulin in order to improve insulin therapy. The available clinical studies of the new insulins are surveyed and show, together with modeling results, that new strategies for optimal basal-bolus treatment are required for utilization of the new fast-acting analogs.

  19. Changes in insulin and insulin signaling in Alzheimer’s disease: cause or consequence?

    Science.gov (United States)

    Stanley, Molly; Macauley, Shannon L.

    2016-01-01

    Individuals with type 2 diabetes have an increased risk for developing Alzheimer’s disease (AD), although the causal relationship remains poorly understood. Alterations in insulin signaling (IS) are reported in the AD brain. Moreover, oligomers/fibrils of amyloid-β (Aβ) can lead to neuronal insulin resistance and intranasal insulin is being explored as a potential therapy for AD. Conversely, elevated insulin levels (ins) are found in AD patients and high insulin has been reported to increase Aβ levels and tau phosphorylation, which could exacerbate AD pathology. Herein, we explore whether changes in ins and IS are a cause or consequence of AD. PMID:27432942

  20. Insulin Resistance

    DEFF Research Database (Denmark)

    Jensen, Benjamin Anderschou Holbech

    Insulin resistance (IR) is escalating with alarming pace and is no longer restricted to westernized countries. As a forerunner for some of the most serious threats to human health including metabolic syndrome, cardiovascular diseases, and type 2-diabetes, the need for new treatment modalities...... interventions. We further show that improving the inflammatory toning, using fish oil as fat source, protects mice against diet induced obesity and -inflammation while preserving insulin sensitivity, even in the absence of free fatty acid receptor 4. Conversely, HFD-induced intestinal dysbiosis is associated...

  1. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  2. Psychological insulin resistance in type 2 diabetes patients regarding oral antidiabetes treatment, subcutaneous insulin injections, or inhaled insulin.

    Science.gov (United States)

    Petrak, Frank; Herpertz, Stephan; Stridde, Elmar; Pfützner, Andreas

    2013-08-01

    "Psychological insulin resistance" (PIR) is an obstacle to insulin treatment in type 2 diabetes, and patients' expectations regarding alternative ways of insulin delivery are poorly understood. PIR and beliefs regarding treatment alternatives were analyzed in patients with type 2 diabetes (n=532; mean glycated hemoglobin, 68±12 mmol/mol [8.34±1.5%]) comparing oral antidiabetes treatment, subcutaneous insulin injections, or inhaled insulin. Questionnaires were used to assess barriers to insulin treatment (BIT), generic and diabetes-specific quality of life (Short Form 36 and Problem Areas in Diabetes, German version), diabetes knowledge, locus of control (Questionnaire for the Assessment of Diabetes-Specific Locus of Control, in German), coping styles (Freiburg Questionnaire of Illness Coping, 15-Items Short Form), self-esteem (Rosenberg Self-Esteem Scale, German version), and mental disorders (Patient Health Questionnaire, German version). Patients discussed treatment optimization options with a physician and were asked to make a choice about future diabetes therapy options in a two-step treatment choice scenario. Step 1 included oral antidiabetes drugs or subcutaneous insulin injection (SCI). Step 2 included an additional treatment alternative of inhaled insulin (INH). Subgroups were analyzed according to their treatment choice. Most patients perceived their own diabetes-related behavior as active, problem-focused, internally controlled, and oriented toward their doctors' recommendations, although their diabetes knowledge was limited. In Step 1, rejection of the recommended insulin was 82%, and in Step 2, it was 57%. Fear of hypoglycemia was the most important barrier to insulin treatment. Patients choosing INH (versus SCI) scored higher regarding fear of injection, expected hardship from insulin therapy, and BIT-Sumscore. The acceptance of insulin is very low in type 2 diabetes patients. The option to inhale insulin increases the acceptability for some but

  3. Oral insulin reloaded: a structured approach.

    Science.gov (United States)

    Zijlstra, Eric; Heinemann, Lutz; Plum-Mörschel, Leona

    2014-05-01

    Optimal coverage of insulin needs is the paramount aim of insulin replacement therapy in patients with diabetes mellitus. To apply insulin without breaking the skin barrier by a needle and/or to allow a more physiological provision of insulin are the main reasons triggering the continuous search for alternative routes of insulin administration. Despite numerous attempts over the past 9 decades to develop an insulin pill, no insulin for oral dosing is commercially available. By way of a structured approach, we aim to provide a systematic update on the most recent developments toward an orally available insulin formulation with a clear focus on data from clinical-experimental and clinical studies. Thirteen companies that claim to be working on oral insulin formulations were identified. However, only 6 of these companies published new clinical trial results within the past 5 years. Interestingly, these clinical data reports make up a mere 4% of the considerably high total number of publications on the development of oral insulin formulations within this time period. While this picture clearly reflects the rising research interest in orally bioavailable insulin formulations, it also highlights the fact that the lion's share of research efforts is still allocated to the preclinical stages. © 2014 Diabetes Technology Society.

  4. Het instellen op insuline van patiënten met diabetes mellitus type 2: In een transmurale organisatievorm minstens even effectief als poliklinisch; een retrospectief onderzoek met 4 jaar follow-up [Initiating insulin therapy in patients with diabetes mellitus type 2: In a transmural form of care at least as effective as an outpatients form; a retrospective study with a 4-year follow-up

    NARCIS (Netherlands)

    Rosendal, H.; Vondeling, H.; Witte, L.P. de; Hutubessy, R.C.W.; Beekum, W.T. van; Heine, R.J.

    2002-01-01

    Objective. Assessing whether the initiation of insulin therapy in patients with diabetes mellitus type 2 can be delivered as effectively in a structured transmural care model as in the more usual outpatients structure. Design. Retrospective comparative cohort study. Method. In 1997 data were

  5. Insulinoterapia na prenhez de ratas diabéticas: repercussões fetais e placentárias Effect of insulin therapy in on pregnancy of diabetic rats: fetal and placental repercussions

    Directory of Open Access Journals (Sweden)

    Marilza V.C. Rudge

    1998-02-01

    Full Text Available O objetivo deste trabalho foi estudar as repercussões feto-placentárias da insulinoterapia na prenhez de ratas diabéticas. A droga diabetogênica foi aloxana na dose de 42 mg/kg de peso por via intravenosa. Formaram-se cinco grupos experimentais: controle (G1, n=12; diabete moderado não-tratado (G2, n=10; diabete moderado tratado com insulina (G3, n=11; diabete grave não-tratado (G4, n=12 e diabete grave tratado com insulina (G5, n=10. Foram obtidos 634 recém-nascidos e respectivas placentas. O resultado perinatal do tratamento com insulina teve relação direta com a qualidade do controle glicêmico. O tratamento inadequado do diabete moderado determinou níveis de hiperglicemia moderada nos recém-nascidos, não interferiu com o peso corporal dos filhotes e diminuiu a proporção de recém-nascidos grandes para a idade da prenhez (GIP. O controle adequado do diabete grave normalizou a glicemia dos recém-nascidos, aumentou o peso dos filhotes e diminuiu a proporção de recém-nascidos pequenos para a idade da prenhez (PIP. A administração de doses adequadas de insulina no grupo de ratas diabéticas grave diminuiu o peso das placentas mas sem modificar o índice placentário.Fetal and placental effects of insulin therapy on pregnancy of diabetic rats were studied. Alloxan was administered intravenously at the dose of 42 mg/kg of body weight. Five experimental groups were formed: control (G1, n=12, non-treated rats with moderate diabetes (G2, n=10, insulin-treated rats with moderate diabetes (G3, n=11,non-treated rats with severe diabetes (G4, n=12 and insulin-treated rats with severe diabetes (G5, n=10. Six hundred and thirty-four newborn rats and placentas wereprocured. The perinatal result of insulin therapy was directly related to the quality of glycemia control. Thus, inadequate control of moderate diabetes produced levels of moderate hyperglycemia, did not interfere with the newborn rats' body weight and decreased the proportion

  6. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  7. Rotary piston blood pumps: past developments and future potential of a unique pump type.

    Science.gov (United States)

    Wappenschmidt, Johannes; Autschbach, Rüdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, Günter; Goetzenich, Andreas

    2016-08-01

    The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.

  8. Anti-insulin antibody test

    Science.gov (United States)

    Insulin antibodies - serum; Insulin Ab test; Insulin resistance - insulin antibodies; Diabetes - insulin antibodies ... Normally, there are no antibodies against insulin in your blood. ... different laboratories. Some labs use different measurements or ...

  9. Severe hypoglycaemia in a person with insulin autoimmune syndrome accompanied by insulin receptor anomaly type B.

    Science.gov (United States)

    Kato, T; Itoh, M; Hanashita, J; Itoi, T; Matsumoto, T; Ono, Y; Imamura, S; Hayakawa, N; Suzuki, A; Mizutani, Y; Uchigata, Y; Oda, N

    2007-11-01

    A rare case of the insulin autoimmune syndrome (IAS) accompanied by insulin receptor anomaly is reported. Antibodies to insulin and insulin receptor were determined in the patient with severe hypoglycaemia before and after the treatment with prednisolone. Titers of antibody to insulin and insulin receptors were 73.0% and 41.5%, respectively. Drug-induced lymphocyte stimulation tests were all negative for the suspicious drugs. Her HLA-DR was DRB1*0403/04051. Following steroid therapy, the formation of antibodies was suppressed and alleviated her symptoms. Scatchard analysis yielded findings specific to polyclonal antibodies. The changes in autoantibodies resulted in alleviation of the hypoglycemic symptoms as a result of steroid therapy.

  10. The effect of tubing dwell time on insulin adsorption during intravenous insulin infusions.

    Science.gov (United States)

    Thompson, Cecilia D; Vital-Carona, Jessica; Faustino, E Vincent S

    2012-10-01

    Insulin adsorbs to plastic tubing, which decreases the concentration of an insulin solution delivered from an intravenous infusion set. Dwelling insulin within tubing before starting the infusion decreases adsorption but delays treatment initiation and wastes time in infusion preparation. The lack of data on dwell time effects results in wide variability in practice. We aim to determine the effect of dwell time on insulin concentration from intravenous infusion tubing. In this in vitro study, we used insulin solutions with concentrations of 0.1 unit/mL, 1 unit/mL, and 10 units/mL. Each solution dwelled in intravenous infusion sets for 0, 15, 30, or 60 min. After the dwell, we measured insulin concentrations from the solution bags and tubing. We repeated each insulin concentration-dwell time combination five times. Comparisons were performed using analyses of variance. For each of the three insulin concentrations, the mean insulin concentrations from the tubing were not significantly different between dwell times. Duration of dwell time did not affect insulin adsorption in polypropylene intravenous infusion sets. We recommend that following a 20-mL flush, insulin infusions can be started without any dwell time. Removal of dwell times may improve clinical practice by minimizing preparation time and will allow faster initiation of insulin infusion therapy.

  11. Insulin inhalation for diabetic patients: Nursing considerations

    Directory of Open Access Journals (Sweden)

    Hanan Mohammed Mohammed

    2016-04-01

    Full Text Available Scientific knowledge has advanced to enable the development of inhaled insulin. It is a form of diabetes medication administered via the pulmonary system that studies have shown to be efficacious in the treatment of both type 1 and type 2 diabetes. Inhaled insulin is a new, safe means to deliver insulin that may increase patient compliance with insulin therapy, helping them to achieve optimal glycemic control and possibly reducing their risk of developing cardiovascular complications. However, diabetes is a chronic illness requiring lifetime intervention. Empowering patients with the knowledge of the diabetes disease process may give them the confidence to be more autonomous in managing their diabetes. HIIP gives nurse practitioners a new option that may improve their patients’ acceptance of insulin therapy, and improve glycemic control.

  12. Insulin analogues: have they changed insulin treatment and improved glycaemic control?

    DEFF Research Database (Denmark)

    Madsbad, Sten

    2002-01-01

    To improve insulin therapy, new insulin analogues have been developed. Two fast-acting analogues with a more rapid onset of effect and a shorter duration of action combined with a low day-to-day variation in absorption rate are now available. Despite this favourable time-action profile most studies....... This is probably the main explanation for the absence of improvement in overall glycaemic control when compared with regular human insulin. A tendency to a reduction in hypoglycaemic events during treatment with fast-acting analogues has been observed in most studies. Recent studies have indicated that NPH insulin...... administered several times daily at mealtimes can improve glycaemic control without increasing the risk of hypoglycaemia. The fast-acting analogues are now also available as insulin mixed with NPH. Insulin glargine is a new long-acting insulin which is soluble and precipitates after injection, resulting...

  13. Combining GLP-1 receptor agonists with insulin

    DEFF Research Database (Denmark)

    Holst, Jens Juul; Vilsbøll, T

    2013-01-01

    Due to the increasing prevalence of type 2 diabetes mellitus (T2DM), the emergent trend towards diagnosis in younger patients and the progressive nature of this disease, many more patients than before now require insulin to maintain glycaemic control. However, there is a degree of inertia among...... physicians and patients regarding the initiation and intensification of insulin therapy, in part due to concerns about the associated weight gain and increased risk of hypoglycaemia. Glucagon-like peptide-1 receptor agonists (GLP-1RAs) increase insulin release and suppress glucagon secretion in a glucose......, compared with insulin, the antihyperglycaemic efficacy of GLP-1RAs is limited. The combination of a GLP-1RA and insulin might thus be highly effective for optimal glucose control, ameliorating the adverse effects typically associated with insulin. Data from clinical studies support the therapeutic...

  14. Treatment of severe insulin resistance in pregnancy with 500 units per milliliter of concentrated insulin.

    Science.gov (United States)

    Mendez-Figueroa, Hector; Maggio, Lindsay; Dahlke, Joshua D; Daley, Julie; Lopes, Vrishali V; Coustan, Donald R; Rouse, Dwight J

    2013-07-01

    To evaluate glycemic control and pregnancy outcomes among pregnant women with severe insulin resistance treated with 500 units/mL concentrated insulin. Retrospective analysis of gravid women with severe insulin resistance (need for greater than 100 units of insulin per injection or greater than 200 units/d) treated with either 500 units/mL concentrated insulin or conventional insulin therapy. We performed a two-part analysis: 1) between gravid women treated with and without 500 units/mL concentrated insulin; and 2) among gravid women treated with 500 units/mL concentrated insulin, comparing glycemic control before and after its initiation. Seventy-three pregnant women with severe insulin resistance were treated with 500 units/mL concentrated insulin and 78 with conventional insulin regimens. Patients treated with 500 units/mL concentrated insulin were older and more likely to have type 2 diabetes mellitus. Average body mass index was comparable between both groups (38.6 compared with 40.4, P=.11) as were obstetric and perinatal outcomes and glycemic control during the last week of gestation. Within the 500 units/mL concentrated insulin cohort, after initiation of this medication, fasting and postprandial blood glucose concentrations improved. However, the rates of blood glucose values less than 60 mg/dL and less than 50 mg/dL were higher in the 500 units/mL concentrated insulin group after initiation than before, 4.8% compared with 2.0% (Pinsulin in severely obese insulin-resistant pregnant women confers similar glycemic control compared with traditional insulin regimens but may increase the risk of hypoglycemia. II.

  15. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  16. Successful transition to sulphonylurea therapy from insulin in a child with permanent neonatal diabetes due to a KCNJ11 gene mutation

    Directory of Open Access Journals (Sweden)

    Venkatesan Radha

    2018-01-01

    Full Text Available Neonatal diabetes mellitus (NDM is a monogenic form of diabetes mellitus that occurs in the first 6 months of life. It is a rare condition with a prevalence of 1 in 100,000–500,000 live births. We report a 3-month-old girl child with high blood glucose levels. She was diagnosed with diabetes mellitus during the 28th day of life and was on treatment with insulin. She was admitted for the control of high blood glucose levels during which she was started on multiple daily insulin treatment, but the control had been poor. As the age of onset is <6 months of life, genetic analysis has been done. It revealed the presence of a heterozygous mutation p. Gly334Val (p. G334V in KCNJ11 gene which confirmed the diagnosis of NDM. The child was successfully shifted from insulin to sulfonylureas, and the blood glucose levels are well maintained.

  17. Neutral insulin solutions physically stabilized by addition of Zn2+.

    Science.gov (United States)

    Brange, J; Havelund, S; Hommel, E; Sørensen, E; Kühl, C

    1986-01-01

    Commercial neutral insulin solutions, all of which contain 2-3 zinc atoms per hexameric unit of insulin, have a relatively limited physical stability when exposed to heat and movement, as for example in insulin infusion pumps. Physical stabilization of neutral insulin solutions has been obtained by addition of two extra Zn2+ per hexamer of insulin. This addition stabilizes porcine and human neutral solutions equally well and does not affect the chemical stability of the insulin. The stabilization is probably obtained by a further strengthening of the hexameric structure of insulin, so that the formation of insoluble insulin fibrils (via the dissociation into the insulin monomer or dimer) is impeded or prevented. The addition of an extra 2 Zn2+ has been shown to be without influence on the insulin immunogenicity in rabbits or on the rate of absorption after subcutaneous injection in diabetic patients. It is concluded that neutral insulin solution can be physically stabilized by addition of extra Zn2+ without affecting other qualities of the insulin preparation including chemical stability, immunogenicity, and duration of action after injection.

  18. The early use of insulin in type 2 diabetes

    Directory of Open Access Journals (Sweden)

    PHILIP LEVY

    2004-06-01

    Full Text Available 60?70% of all patients with Type 2 Diabetes Mellitus will ultimately require insulin therapy for the management of their diabetes. Irisulin may be used alone, or in combination with oral agents. The early use of insulin can be very important in decreasing the incidence of micro-vascular complications and in helping to delay the onset of macro-vascular complications. The United Kingdom Prospective Diabetes Study and the Kumamoto Study have shown the beneficial effects of good glucose control in type 2 diabetes mellitus. The DECODE study has related overall mortality to the level of glucose control and specifically to the postprandial glucose. The American Association of Clinical Endocrinologists has established a goal of 6.5% or less for HgbAlc. The appropriate use of insulin will allow us to achieve this goal without causing the patient any undue harm. There are many barriers to insulin therapy including psychological barriers of both the patient and the doctor, and unrealistic fears of both insulin therapy and therapy with self-administered injections. These barriers will be discussed as well as methods to overcome them. Insulin therapy is beneficial and has no long term adverse effects. The incidence of severe hypoglycemia is extremely low in type 2 diabetes. Weight gain is minimal. Insulin therapy by reducing glucose toxicity may also increase the effectiveness of oral anti-hyperglycemic agents. The physician taking care of patients with diabetes should be aggressive and should have no fears of initiating insulin therapy. Insulin dosage is flexible and good control is possible in most patients. The most common use of insulin in type 2 diabetes is as an add-on to oral agents if control with oral agents alone is unsatisfactory. Frequently this involves the use of a single dose of intermediate or long acting insulin or an insulin mixture in the evening. If control is not attained with a single dose, then the patient can be placed on an insulin

  19. The effects of calcitriol on improvement of insulin resistance, ovulation and comparison with metformin therapy in PCOS patients: a randomized placebo- controlled clinical trial.

    Science.gov (United States)

    Bonakdaran, Shokoufeh; Mazloom Khorasani, Zahra; Davachi, Behrooz; Mazloom Khorasani, Javad

    2012-09-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine disorder in females of reproductive age. Insulin resistance is a frequent metabolic disturbance in PCOS. Vitamin D deficiency is a common problem. Accumulating evidence suggests that vitamin D has a role on insulin sensitivity so may contribute to reduction of hyperandrogenemia. The aim was to determine the effects of vitamin D treatment in metabolic components and ovulation evidence in PCOS. Fifty one untreated PCOS patients were randomly divided into three groups and treated with calcitriol, metformin, or placebo. Before and 3 months after treatment, ovulation evidence was assessed by ovarian trans abdominal sonography. Plasma fasting glucose, insulin, homeostasis model assessment insulin resistance (HOMA-IR), 25-hydroxyvitamin D, parathyroid hormone and androgen levels were measured before and after treatment. A 75gr glucose test was performed before and after treatment and two set of results was compared. Three patients did not continue this study. Only 11 patient (22.9%) had sufficient vitamin D levels (>30 ng/ml). Metformin caused a significant decrease in weight (p=0.027), insulin level (p=0.043), and insulin resistance (p=0.048). Systolic blood pressure and PTH significantly improved after calcitriol (p=0.029, p=0.009 respectively). An improvement in ovulation was detected after calcitriol and seven patients, without evidence of ovulation before treatment, illustrated ovulation after 3 months. Difference with calcitriol in ovulation was significant versus other two methods (p=0.02). Calcitriol treatment in PCOS may be prior to metformin in ovulation induction.