WorldWideScience

Sample records for instruments viii catheters

  1. Safety Research Experiment Facility Project. Conceptual design report. Volume VIII. Instrumentation and control

    International Nuclear Information System (INIS)

    1975-01-01

    Included are sections dealing with the following: nuclear instrumentation system, reactor control system, plant protection system, plant annunciator system, data acquisition system, and reactor cooling system instrumentation and control

  2. Planck 2015 results: VIII. High Frequency Instrument data processing: Calibration and maps

    DEFF Research Database (Denmark)

    Adam, R.; Ade, P. A R; Aghanim, N.

    2016-01-01

    This paper describes the processing applied to the cleaned, time-ordered information obtained from the Planck High Frequency Instrument (HFI) with the aim of producing photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5-year HFI....... Using a CMB temperature of TCMB = 2.7255 ± 0.0006 K, it permits an independent measurement of the amplitude of the CMB solar dipole (3364.3 ± 1.5 μK), which is approximatively 1σ higher than the WMAP measurement with a direction that is consistent between the two experiments. We describe the pipeline...... used to produce the maps ofintensity and linear polarization from the HFI timelines, and the scheme used to set the zero level of the maps a posteriori. We also summarize the noise characteristics of the HFI maps in the 2015 Planck data release and present some null tests to assess their quality...

  3. Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps

    CERN Document Server

    Adam, R.; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bertincourt, B.; Bielewicz, P.; Bock, J.J.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bucher, M.; Burigana, C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, H.C.; Christensen, P.R.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Falgarone, E.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Ghosh, T.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Le Jeune, M.; Leahy, J.P.; Lellouch, E.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Moreno, R.; Morgante, G.; Mortlock, D.; Moss, A.; Mottet, S.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Pearson, T.J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Watson, R.; Wehus, I.K.; Yvon, D.; Zacchei, A.

    2016-01-01

    This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the 2.5 year full mission include almost five independent full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system and permits an independent measurement of the amplitude of the CMB solar dipole (3364.5 +/- 0.8 \\mu K) which is 1\\sigma\\ higher than the WMAP measurement wit...

  4. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  6. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    Science.gov (United States)

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  12. Factor VIII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003678.htm Factor VIII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  6. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  7. Blood coagulation factor VIII

    Indian Academy of Sciences (India)

    Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  10. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  7. The vestibulocochlear nerve (VIII).

    Science.gov (United States)

    Benoudiba, F; Toulgoat, F; Sarrazin, J-L

    2013-10-01

    The vestibulocochlear nerve (8th cranial nerve) is a sensory nerve. It is made up of two nerves, the cochlear, which transmits sound and the vestibular which controls balance. It is an intracranial nerve which runs from the sensory receptors in the internal ear to the brain stem nuclei and finally to the auditory areas: the post-central gyrus and superior temporal auditory cortex. The most common lesions responsible for damage to VIII are vestibular Schwannomas. This report reviews the anatomy and various investigations of the nerve. Copyright © 2013. Published by Elsevier Masson SAS.

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  11. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  12. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  13. Structural Instability in Ice VIII under Pressure

    International Nuclear Information System (INIS)

    Besson, J.; Klotz, S.; Hamel, G.; Marshall, W.; Nelmes, R.; Loveday, J.

    1997-01-01

    Below 125K, tetragonal ice VIII remains in a metastable form at ambient pressure. This form has long been considered to be identical to ice VIII, although unexplained discrepancies exist between their vibrational spectra. Neutron diffraction studies reveal an isostructural phase transformation below 2GPa related to a weakening of the bonds between the two D 2 O sublattices of ice VIII. In this new phase, ice VIII ' , the tetragonal distortion is 20% larger than in ice VIII, which accounts for the differences between the vibrational frequencies of the two phases. copyright 1997 The American Physical Society

  14. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  15. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  16. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  17. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  18. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  1. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  2. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  3. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  4. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  5. VIII International Congress of Engineering Physics

    International Nuclear Information System (INIS)

    2017-01-01

    The Physicist Engineering is a multidisciplinary profession in which an undergraduate student integrates and applies their knowledge of Physics, Mathematics, and Computing to adapt and innovate all kind of technologies, as well as to development and apply theoretical knowledge to different fields of science and engineering. A Physicist Engineer, supported by a solid preparation in science and engineering is available to study, analyze, identify, and solve problems in different fields of science and technology for industries, hospitals, research laboratories, institutes and governmental organizations focused on metrology, optics, energy, materials, instrumentation of sophisticated equipment. The Physicist Engineering bachelor degree is a national and international reference to encouraging all those students to apply knowledge through active participation in the operation, planning, and management of projects. The technological and scientific impact of a Physicist Engineering undergraduate and graduate students, as well as the tutorial of the research professor that are interested in Physics and Physics Engineering, may be found in a biennial event like the International Conference on Physicist Engineering, through the diffusion of both experimental and theoretical research and teaching. In order to promote and encourage strength academic goals among universities and research institutions, the International Conference on Physics Engineering Committee, integrated by a faculty meeting of the Universidad Autónoma Metropolitana, Campus Azcapotzalco, has decided to grant the VIII International Congress of Physics Engineering to the Universidad Autónoma de Yucatán, which is going to take place on Mérida, November 7 th to 11 th , 2016. This conference considers different topics as: Renewables Energies Engineering Materials Technology Nanotechnology Medical Physics Education in Physics Engineering Nuclear Engineering High Precision Instrumentation Atmosphere Physics

  6. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  7. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  8. 77 FR 64401 - Order of Succession for HUD Region VIII

    Science.gov (United States)

    2012-10-19

    ... Region VIII AGENCY: Office of Field Policy and Management, HUD. ACTION: Notice of Order of Succession... Field Offices (Region VIII). This Order of Succession supersedes all previous Orders of Succession for HUD Region VIII. DATES: Effective Date: October 9, 2012. FOR FURTHER INFORMATION CONTACT: Lawrence D...

  9. [Ehler-Danlos syndrome type VIII].

    Science.gov (United States)

    Ciarloni, L; Perrigouard, C; Lipsker, D; Cribier, B

    2010-03-01

    Ehlers-Danlos syndrome (EDS) comprises a heterogeneous group of diseases involving genetic collagen fibre impairment. We describe a case of a patient presenting the rare type VIII, in which dermatitis ocre was associated with parodontal disease, and which was diagnosed late. A 29-year-old man consulted for a pretibial ulcer present for seven years, resulting from a post-traumatic haematoma that had failed to heal. In view of the longiliner morphology, it had previously been diagnosed as Marfan syndrome. Subsequently, edentation was observed as well as "alveolar bone fragility". Examination revealed a marfanoid morphotype, a pretibial ulcer set within long-standing bilateral dermatitis ocre and papyraceous scars, but no joint hyperlaxity or cutaneous hyperelasticity. The diagnosis was consequently corrected to EDS type VIII. Type VIII is a rare form of EDS, and the molecular mechanism is poorly understood. The involvement of parodontal connective tissue suggests impairment of collagen I and III proteins. It is important to identify this type of the disease since it involves parodontal disease for which early treatment is required in order to try to prevent edentation. The present case demonstrates the importance of diagnosis, which may be based upon appearance of bilateral dermatitis ocre from the age of 15 years associated with skin fragility. This sign is not part of the classical picture of Marfan syndrome, with which EDS type VIII is often confounded. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  10. Catheter-associated UTI

    Science.gov (United States)

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  11. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  12. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  13. Distributed pressure sensors for a urethral catheter.

    Science.gov (United States)

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S

    2015-01-01

    A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi.

  14. Influence of Problem Based Learning on Critical Thinking Skills and Competence Class VIII SMPN 1 Gunuang Omeh, 2016/2017

    Science.gov (United States)

    Aswan, D. M.; Lufri, L.; Sumarmin, R.

    2018-04-01

    This research intends to determine the effect of Problem Based Learning models on students' critical thinking skills and competences. This study was a quasi-experimental research. The population of the study was the students of class VIII SMPN 1 Subdistrict Gunuang Omeh. Random sample selection is done by randomizing the class. Sample class that was chosen VIII3 as an experimental class given that treatment study based on problems and class VIII1 as control class that treatment usually given study. Instrument that used to consist of critical thinking test, cognitive tests, observation sheet of affective and psychomotor. Independent t-test and Mann Whitney U test was used for the analysis. Results showed that there was significant difference (sig competences.

  15. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  16. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.

    Science.gov (United States)

    Kesner, Samuel B; Howe, Robert D

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.

  17. Development and characterization of recombinant ovine coagulation factor VIII.

    Directory of Open Access Journals (Sweden)

    Philip M Zakas

    Full Text Available Animal models of the bleeding disorder, hemophilia A, have been an integral component of the biopharmaceutical development process and have facilitated the development of recombinant coagulation factor VIII (fVIII products capable of restoring median survival of persons with hemophilia A to that of the general population. However, there remain several limitations to recombinant fVIII as a biotherapeutic, including invasiveness of intravenous infusion, short half-life, immunogenicity, and lack of availability to the majority of the world's population. The recently described ovine model of hemophilia A is the largest and most accurate phenocopy. Affected sheep die prematurely due to bleeding-related pathogenesis and display robust adaptive humoral immunity to non-ovine fVIII. Herein, we describe the development and characterization of recombinant ovine fVIII (ofVIII to support further the utility of the ovine hemophilia A model. Full-length and B-domain deleted (BDD ofVIII cDNAs were generated and demonstrated to facilitate greater biosynthetic rates than their human fVIII counterparts while both BDD constructs showed greater expression rates than the same-species full-length versions. A top recombinant BDD ofVIII producing baby hamster kidney clone was identified and used to biosynthesize raw material for purification and biochemical characterization. Highly purified recombinant BDD ofVIII preparations possess a specific activity nearly 2-fold higher than recombinant BDD human fVIII and display a differential glycosylation pattern. However, binding to the carrier protein, von Willebrand factor, which is critical for stability of fVIII in circulation, is indistinguishable. Decay of thrombin-activated ofVIIIa is 2-fold slower than human fVIII indicating greater intrinsic stability. Furthermore, intravenous administration of ofVIII effectively reverses the bleeding phenotype in the murine model of hemophilia A. Recombinant ofVIII should facilitate

  18. The influence of prophylactic factor VIII in severe hemophilia A

    Science.gov (United States)

    Gissel, Matthew; Whelihan, Matthew F; Ferris, Lauren A; Mann, Kenneth G; Rivard, Georges E; Brummel-Ziedins, Kathleen E

    2013-01-01

    Introduction Hemophilia A individuals displaying a similar genetic defect have heterogeneous clinical phenotypes. Aim To evaluate the underlying effect of exogenous factor (f)VIII on tissue factor (Tf)-initiated blood coagulation in severe hemophilia utilizing both empirical and computational models. Methods We investigated twenty-five clinically severe hemophilia A patients. All individuals were on fVIII prophylaxis and had not received fVIII from 0.25 to 4 days prior to phlebotomy. Coagulation was initiated by the addition of Tf to contact-pathway inhibited whole blood ± an anti-fVIII antibody. Aliquots were quenched over 20 min and analyzed for thrombin generation and fibrin formation. Coagulation factor levels were obtained and used to computationally predict thrombin generation with fVIII set to either zero or its value at the time of the draw. Results Due to prophylactic fVIII, at the time of the blood draw, the individuals had fVIII levels that ranged from hemophilia A. The combination of each individual's coagulation factors (outside of fVIII) determine each individual's baseline thrombin potential and may affect bleeding risk. PMID:21899664

  19. The labour ward analgesic service at King Edward VIII Hospital ...

    African Journals Online (AJOL)

    The labour ward analgesic service at King Edward VIII. Hospital, Durban. D. A. ROCKE, C. C. ROUT, H. D. RUSSELL, S. SINGH. Abstract The provision of analgesic services to the labour ward at King Edward VIII Hospital was studied during a I-week period. Of249 patients, 113 (45%) received no analgesia whatsoever.

  20. One-electron spectrum of Xe VIII

    International Nuclear Information System (INIS)

    Roberts, J.R.; Knystautas, E.J.; Sugar, J.

    1979-01-01

    The spectrum of Xe VIII has been observed in a theta-pinch discharge. New line identifications were made that determine the energies of the 6s, 7s, 6p, and 5f terms relative to the 5s 2 S ground state and confirm the previously known 5p and 5d terms. An independent system of levels derived from the observed 4f-ng (n = 5,6) transitions was found. Its position relative to the ground state is obtained from a predicted value for the 5g effective quantum number n*. From the ns series (n=5--7) a value for the ionization enegy of 105.91 +- 0.05 eV was derived

  1. VIII International Meeting on Lorentzian Geometry

    CERN Document Server

    Flores, José; Palomo, Francisco; GeLoMa 2016; Lorentzian geometry and related topics

    2017-01-01

    This volume contains a collection of research papers and useful surveys by experts in the field which provide a representative picture of the current status of this fascinating area. Based on contributions from the VIII International Meeting on Lorentzian Geometry, held at the University of Málaga, Spain, this volume covers topics such as distinguished (maximal, trapped, null, spacelike, constant mean curvature, umbilical...) submanifolds, causal completion of spacetimes, stationary regions and horizons in spacetimes, solitons in semi-Riemannian manifolds, relation between Lorentzian and Finslerian geometries and the oscillator spacetime. In the last decades Lorentzian geometry has experienced a significant impulse, which has transformed it from just a mathematical tool for general relativity to a consolidated branch of differential geometry, interesting in and of itself. Nowadays, this field provides a framework where many different mathematical techniques arise with applications to multiple parts of mathem...

  2. VIII Brazilian Meeting on Simulational Physics (BMSP)

    International Nuclear Information System (INIS)

    Branco, N. S.; Figueiredo, W.; Plascak, J. A.; Santos, M.

    2016-01-01

    This special issue includes invited and selected articles of the VIII Brazilian Meeting on Simulational Physics (BMSP), held in Florianópolis, Santa Catarina, Brazil, from 3rd to 8th August, 2015. This is the eighth such meeting, and the second one to have contributed papers published in Journal of Physics: Conference Series (the other was the VII BMSP). The previous meetings in the BMSP series took place in the mountains of Minas Gerais, in the region of the Brazilian Pantanal, and in the shores of Paraíba. Now, for the first time, the Meeting was held in Florianópolis, with its pleasing shores, the capital of Santa Catarina state. The VIII BMSP brought together about 50 researchers from all over the world for a vibrant and productive conference. As in the previous meetings, the talks and posters highlighted recent advances in applications, algorithms, and implementation of computer simulation methods for the study of condensed matter, materials, and out of equilibrium, quantum and biologically motivated systems. We are sure that this meeting series will continue to be an important occasion for people working in simulational physics to exchange ideas and discuss the state of the art of this always expanding field. We are very glad to put together this special issue, and are most appreciative of the efforts of the editors of the Journal of Physics: Conference Series for making this publication possible. We are grateful for the outstanding work of the Florianopolis team, for the financial support of the Brazilian agencies CAPES and CNPq, and of the Federal Universities UFPB and UFSC. At last, but not least, we would like to acknowledge all of the authors for their written submissions. (paper)

  3. Factoring in Factor VIII With Acute Ischemic Stroke.

    Science.gov (United States)

    Siegler, James E; Samai, Alyana; Albright, Karen C; Boehme, Amelia K; Martin-Schild, Sheryl

    2015-10-01

    There is growing research interest into the etiologies of cryptogenic stroke, in particular as it relates to hypercoagulable states. An elevation in serum levels of the procoagulant factor VIII is recognized as one such culprit of occult cerebral infarctions. It is the objective of the present review to summarize the molecular role of factor VIII in thrombogenesis and its clinical use in the diagnosis and prognosis of acute ischemic stroke. We also discuss the utility of screening for serum factor VIII levels among patients at risk for, or those who have experienced, ischemic stroke. © The Author(s) 2015.

  4. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  5. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  6. Interventional MRA: concepts for active visualization of catheters and stents

    International Nuclear Information System (INIS)

    Quick, H.H.; Ladd, M.E.

    2003-01-01

    A precondition to safe guidance of vascular guidewires and catheters during the course of magnetic resonance (MR)-guided vascular intervention is a high-contrast visualization of the instruments. The integration of miniature radiofrequency (RF) coils and coaxial cables into guidewires and catheters enables the reception of RF signal from the lumen of blood vessels, and thus the active visualization of the instruments. Moreover, metallic vascular implants (stents) can be modified to act as intravascular RF antennas that inductively couple their RF signal to a conventional surface RF coil. Such stent resonators show signal amplification inside the lumen of the stent and thus can be visualized with high contrast in MR images. Furthermore, once such a device has been implanted, the method offers the potential for non-invasive long-term follow-up of the stent patency. (orig.) [de

  7. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  8. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  9. Translumbar aortography by catheter technique

    International Nuclear Information System (INIS)

    Hagen, B.; Honemeyer, U.; Meier-Duis, H.

    1982-01-01

    400 examinations performed during the last three years by TLA (only catheter technique) were subjected to critical analysis and studied particularly in respect to the rate of complications. We observed 13 complications (3.25%) of moderate severity, including 3 large hematomas (documented by CT), 3 paravasations and 7 dissections, but no fatal complication. Two (0.5%) of these complications had clinical evidence. The advantages of the catheter technique of TLA are described. Injections through rigid metal cannula should be avoided because of the high incidence of complications (mainly the increased risk of dissection). Downstream injection resulted in excellent visualization of peripheral occluding vascular disease. Upstream injection should be preferred to demonstrate the major abdominal arteries as well as supraceliac collateral circulation in the case of high Leriche syndrome. The low or intermediate puncture of the aorta is preferable to facilitate caudad direction of the catheter and to diminish the risk of damaging other vessels or puncturing an organ. (orig.) [de

  10. PENGARUH PENGUASAAN KONSEP TEOREMA PYTHAGORAS TERHADAP KEMAMPUAN MENYELESAIKAN SOAL-SOAL BANGUN RUANG SISI DATAR PADA SISWA KELAS VIII MTS NEGERI BALANG-BALANG

    Directory of Open Access Journals (Sweden)

    Syahrida Zaerani

    2017-12-01

    Abstract: This study aims to determine the impact of the mastery of Pythagoras Theorem concepts on the ability of MTs Negeri Balang-Balang grade VIII students to solve polyhedron problems. This study is a quantitative research with ex post facto design. Statistical population consists of all grade VIII students in MTs Negeri Balang-Balang which was 204 students. The number of sampling used is 102 respondents taken by simple random sampling technique. The research instrument was a test related to Pythagorean an polyhedron problems. Descriptive and inferential statistics were performed as the statistical analysis. The descriptive analysis result shows that the mastery of Pythagoras Theorem concepts is within the category of ‘high’ and the ability of solving polyhedron problems is as well. The inferential statistical analysis using simple linear regression shows that there is an impact of the mastery of Pythagoras Theorem concepts on polyhedron problem solving ability of Grade VIII students of MTs Negeri Balang-Balang.

  11. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  12. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  13. AAV5-Factor VIII Gene Transfer in Severe Hemophilia A.

    Science.gov (United States)

    Rangarajan, Savita; Walsh, Liron; Lester, Will; Perry, David; Madan, Bella; Laffan, Michael; Yu, Hua; Vettermann, Christian; Pierce, Glenn F; Wong, Wing Y; Pasi, K John

    2017-12-28

    Patients with hemophilia A rely on exogenous factor VIII to prevent bleeding in joints, soft tissue, and the central nervous system. Although successful gene transfer has been reported in patients with hemophilia B, the large size of the factor VIII coding region has precluded improved outcomes with gene therapy in patients with hemophilia A. We infused a single intravenous dose of a codon-optimized adeno-associated virus serotype 5 (AAV5) vector encoding a B-domain-deleted human factor VIII (AAV5-hFVIII-SQ) in nine men with severe hemophilia A. Participants were enrolled sequentially into one of three dose cohorts (low dose [one participant], intermediate dose [one participant], and high dose [seven participants]) and were followed through 52 weeks. Factor VIII activity levels remained at 3 IU or less per deciliter in the recipients of the low or intermediate dose. In the high-dose cohort, the factor VIII activity level was more than 5 IU per deciliter between weeks 2 and 9 after gene transfer in all seven participants, and the level in six participants increased to a normal value (>50 IU per deciliter) that was maintained at 1 year after receipt of the dose. In the high-dose cohort, the median annualized bleeding rate among participants who had previously received prophylactic therapy decreased from 16 events before the study to 1 event after gene transfer, and factor VIII use for participant-reported bleeding ceased in all the participants in this cohort by week 22. The primary adverse event was an elevation in the serum alanine aminotransferase level to 1.5 times the upper limit of the normal range or less. Progression of preexisting chronic arthropathy in one participant was the only serious adverse event. No neutralizing antibodies to factor VIII were detected. The infusion of AAV5-hFVIII-SQ was associated with the sustained normalization of factor VIII activity level over a period of 1 year in six of seven participants who received a high dose, with

  14. Idiopathic Acquired Hemophilia A with Undetectable Factor VIII Inhibitor

    Directory of Open Access Journals (Sweden)

    Nicholas B. Abt

    2014-01-01

    Full Text Available Objective. We present the case of a 73-year-old female, with no family or personal history of a bleeding disorder, who had a classic presentation for acquired hemophilia A. Factor VIII activity was low but detectable and a factor VIII inhibitor was undetectable. Methods. The patient’s plasma was comprehensively studied to determine the cause of the acquired coagulopathy. Using the Nijmegen modification of the Bethesda assay, no factor VIII autoantibody was measureable despite varying the incubation time from 1 to 3 hours. Results. The aPTT was prolonged at 46.8 seconds, which did not correct in the 4 : 1 mix but did with 1 : 1 mix. Using a one stage factor VIII activity assay, the FVIII activity was 16% and chromogenic FVIII activity was also 16%. The patient was treated with recombinant FVII and transfusion, significantly reducing bleeding. Long-term therapy was initiated with cyclophosphamide and prednisone with normalization of FVIII activity. Conclusions. Physicians can be presented with the challenging clinical picture of an acquired factor VIII inhibitor without a detectable inhibitor by the Bethesda assay. Standard therapy for an acquired hemophilia A should be considered.

  15. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  16. Acquired high titre factor VIII inhibitor with underlying polyarteritis nodosa.

    Science.gov (United States)

    Snowden, J A; Hutchings, M; Spearing, R; Patton, W N

    1997-05-01

    We here present the case of a 70-year-old woman referred to our unit for investigation of bleeding. Investigations confirmed a high titre acquired Factor VIII inhibitor. In association there was relapse of systemic illness associated with anti-neutrophil cytoplasmic antibodies (atypical pattern) for which she had been treated five years previously. Immunosuppression was attempted, but it failed to have an impact both on the inhibitor titre and on the underlying disorder. The patient died from multi-organ failure and massive chest hemorrhage. Post-mortem showed necrotizing vasculitis of medium sized vessels at several sites, including the kidney, consistent with a diagnosis of polyarteritis nodosa. Although it is well recognised that Factor VIII inhibitors are found in conjunction with autoimmune disorders, this case is significant in that it is the first associated with histologically proven polyarteritis nodosa type vasculitis. The case illustrates the difficulties in the investigation and management of patients with acquired high titre Factor VIII inhibitors.

  17. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  18. Improving attitudes toward mathematics learning with problem posing in class VIII

    Science.gov (United States)

    Vionita, Alfha; Purboningsih, Dyah

    2017-08-01

    This research is classroom action research which is collaborated to improve student's behavior toward math and mathematics learning at class VIII by using problem posing approach. The subject of research is all of students grade VIIIA which consist of 32 students. This research has been held on two period, first period is about 3 times meeting, and second period is about 4 times meeting. The instrument of this research is implementation of learning observation's guidance by using problem posing approach. Cycle test has been used to measure cognitive competence, and questionnaire to measure the students' behavior in mathematics learning process. The result of research shows the students' behavior has been improving after using problem posing approach. It is showed by the behavior's criteria of students that has increasing result from the average in first period to high in second period. Furthermore, the percentage of test result is also improve from 68,75% in first period to 78,13% in second period. On the other hand, the implementation of learning observation by using problem posing approach has also improving and it is showed by the average percentage of teacher's achievement in first period is 89,2% and student's achievement 85,8%. These results get increase in second period for both teacher and students' achievement which are 94,4% and 91,11%. As a result, students' behavior toward math learning process in class VIII has been improving by using problem posing approach.

  19. The catheter and its use from Hippocrates to Galen.

    Science.gov (United States)

    Moog, Ferdinand Peter; Karenberg, Axel; Moll, Friedrich

    2005-10-01

    We comprehensively reviewed the history and use of the bladder catheter in Western medicine from 500 BC to 200 AD. Greek and Latin texts were key word searched to identify descriptions of contemporary instruments and their uses. The catheter and its use were mentioned by about 10 ancient authors in more than a total of 20 texts dating to the end of the second century AD. The authors include Hippocrates, Celsus, Soranus, Rufus, Aretaeus and Galen. They described the use of the instrument in reference to contemporary anatomy and physiology, and indications and contraindications in regard to certain conditions, such as urinary retention, bladder stones and intravesical blood clots. Technical details and particularities of use were also reviewed, as were pharmacological considerations and underlying physical principles. Knowledge of the urinary catheter, and its usefulness and risks in ancient medicine can be dated from the 5th century BC. Our study of European texts documents its broad use. Because catheterization was perceived as a practical measure, it generated little scientific controversy.

  20. Peripheral intravenous and central catheter algorithm: a proactive quality initiative.

    Science.gov (United States)

    Wilder, Kerry A; Kuehn, Susan C; Moore, James E

    2014-12-01

    Peripheral intravenous (PIV) infiltrations causing tissue damage is a global issue surrounded by situations that make vascular access decisions difficult. The purpose of this quality improvement project was to develop an algorithm and assess its effectiveness in reducing PIV infiltrations in neonates. The targeted subjects were all infants in our neonatal intensive care unit (NICU) with a PIV catheter. We completed a retrospective chart review of the electronic medical record to collect 4th quarter 2012 baseline data. Following adoption of the algorithm, we also performed a daily manual count of all PIV catheters in the 1st and 2nd quarters 2013. Daily PIV days were defined as follows: 1 patient with a PIV catheter equals 1 PIV day. An infant with 2 PIV catheters in place was counted as 2 PIV days. Our rate of infiltration or tissue damage was determined by counting the number of events and dividing by the number of PIV days. The rate of infiltration or tissue damage was reported as the number of events per 100 PIV days. The number of infiltrations and PIV catheters was collected from the electronic medical record and also verified manually by daily assessment after adoption of the algorithm. To reduce the rate of PIV infiltrations leading to grade 4 infiltration and tissue damage by at least 30% in the NICU population. Incidence of PIV infiltrations/100 catheter days. The baseline rate for total infiltrations increased slightly from 5.4 to 5.68/100 PIV days (P = .397) for the NICU. We attributed this increase to heightened awareness and better reporting. Grade 4 infiltrations decreased from 2.8 to 0.83/100 PIV catheter days (P = .00021) after the algorithm was implemented. Tissue damage also decreased from 0.68 to 0.3/100 PIV days (P = .11). Statistical analysis used the Fisher exact test and reported as statistically significant at P < .05. Our findings suggest that utilization of our standardized decision pathway was instrumental in providing guidance for

  1. Igor Zabel 14. VIII 1958 - 23. VII 2005

    Index Scriptorium Estoniae

    2005-01-01

    Igor Zabel oli Ida-Euroopa tuntumaid kunstiteoreetikuid ja kuraatoreid. Töötas 1986. aastast Ljubljana moodsa kunsti muuseumi kuraatorina. 9. VIII avatakse seal viimane I. Zabeli kureeritud näitus "Territories, Identities, Nets-Slovene Art 1995-2005"

  2. Extended analyses of Se VII and Se VIII

    International Nuclear Information System (INIS)

    Vankleef, Th.A.M.; Joshi, Y.N.

    1984-01-01

    Joshi et al. (1984) have conducted an analysis of the 3d8 4s-3d8 4p transitions in As VII. The present investigation is concerned with an analysis of similar transitions in Se VIII. The selenium spectrum was photographed in the 400-1200-A wavelength region on a variety of normal-incidence spectrographs. Attention is given to least-squares-fit (LSF) and Hartree-Fock (HF) parameter values for the 3d9 4d configuration of Se VII, LSF and HF parameter values for the 3d8 4s and 3d8 4p configurations of Se VIII, the energy and composition of the levels of the 3d9 4d configuration of Se VII, classified lines in Se VII, energy levels and composition of the 3d8 4s configuration and the revised and newly determined levels of the 3d8 4p configuration of Se VIII, and newly classified lines of Se VIII. 15 references

  3. Factor VIII-associated antigen in human lymphatic endothelium.

    Science.gov (United States)

    Nagle, R B; Witte, M H; Martinez, A P; Witte, C L; Hendrix, M J; Way, D; Reed, K

    1987-03-01

    Lymphatic vascular endothelium both on tissue section and in culture exhibits positivity for Factor VIII-associated antigen although staining is generally less intense and more spotty than in comparable blood vascular endothelium. Lymphatic endothelium also exhibits Weibel-Palade bodies. Neither marker, therefore, reliably distinguishes blood vascular endothelium from lymphatic endothelium.

  4. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  5. Lung abscess; Percutaneous catheter therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ha, H.K. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Kang, M.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Park, J.M. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Yang, W.J. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Shinn, K.S. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Bahk, Y.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of))

    1993-07-01

    Lung abscess was successfully treated with percutaneous drainage in 5 of 6 patients. Complete abscess resolution occurred in 4 patients, partial resolution in one, and no response in one. The duration of drainage ranged from 7 to 18 days (mean 15.5 days) in successful cases. The failure of drainage in one neurologicall impaired patient was attributed to persistent aspiration. In 2 patients, concurrent pleural empyema was also cured. CT provided the anatomic details necessary for choosing the puncture site and avoiding puncture of the lung parenchyma. Percutaneous catheter drainage is a safe and effective method for treating lung abscess. (orig.).

  6. New study on the XeVIII spectrum

    International Nuclear Information System (INIS)

    Gallardo, M.; Raineri, M.; Giuliani, M.; Lagorio, C.; Padilla, S.; Sarmiento, R.; Reyna Almandos, J.G.

    2005-01-01

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters

  7. Evidence for the formation of sodium hassate(VIII)

    International Nuclear Information System (INIS)

    Zweidorf, A. von; Angert, R.; Bruechle, W.; Buerger, S.; Eberhardt, K.; Eichler, R.; Hummrich, H.; Jaeger, E.; Kling, H.O.; Kratz, J.V.; Kuczewski, B.; Langrock, G.; Mendel, M.; Rieth, U.; Schaedel, M.; Schausten, B.; Schimpf, E.; Thoerle, P.; Trautmann, N.; Tsukada, K.; Wiehl, N.; Wirth, G.

    2004-01-01

    Hassium, element 108, was produced in the fusion reaction between 26 Mg and 248 Cm. The hassium recoils were oxidized in-situ to a highly volatile oxide, presumably HsO 4 , and were transported in a mixture of He and O 2 to a deposition and detection system. The latter consisted of 16 silicon PIN-photodiodes facing a layer of NaOH, which served, in the presence of a certain partial pressure of water in the transport gas, as reactive surface for the deposition of the volatile tetroxides. Six correlated α-decay chains of Hs were detected in the first 5 detectors centred around detection position 3. In analogy to OsO 4 , which forms Na 2 [OsO 4 (OH) 2 ], an osmate(VIII), with aqueous NaOH, HsO 4 presumably was deposited as Na 2 [HsO 4 (OH) 2 ], a hassate(VIII). (orig.)

  8. Henry VIII, McLeod syndrome and Jacquetta's curse.

    Science.gov (United States)

    Stride, P; Lopes Floro, K

    2013-01-01

    The mental decline of King Henry VIII from being a jovial, charismatic and athletic young man into an increasingly paranoid, brutal tyrant in later life, ever more concerned at his lack of one or more male heirs, has attracted many medical diagnostic theories. Previous hypotheses have included diabetes, syphilis and hypothyroidism, among others. However, these inadequately explain Henry's failure to produce a male heir, despite multiple pairings. The latest postulated diagnoses for Henry are the coexistence of both Kell blood group antigenicity (possibly inherited from Jacquetta Woodville, Henry's maternal great grandmother) causing related impaired fertility, and McLeod syndrome, causing psychotic changes. As the mutated McLeod protein of the syndrome significantly reduces the expression, effectively inactivating the Kell antigen, we critically review this theory, examining in detail the pathophysiology of these conditions and assessing the genealogy of Henry VIII and its effect in subsequent generations.

  9. New study on the XeVIII spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: gallardom@ciop.unlp.edu.ar; Raineri, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: monicar@ciop.unlp.edu.ar; Giuliani, M. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Lagorio, C. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Padilla, S. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Sarmiento, R. [Dto. De Fisica, Universidad del Atlantico, A.A 1890 Barranquilla (Colombia); Reyna Almandos, J.G. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: jreyna@ciop.unlp.edu.ar

    2005-10-15

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters.

  10. The spectrum and term system of S VIII

    International Nuclear Information System (INIS)

    Bengtsson, P.; Jupen, C.; Engstroem, L.; Redfors, A.; Westerlind, M.

    1993-01-01

    The spectrum of seven times ionized sulfur, S VIII, has been observed in the wavelength range 50-1200 A. Both beam-foil and laser-produced plasma light sources have been used. 71 new lines representing the transitions 2p 5 -2p 4 3d, 2p 4 3s-3p, 3p-3d, 3d-4f, 4f-5g and 5g-6h have been identified and 100 energy levels, of which 46 are new, are now accurately established. The spectral analysis is supported by isoelectronic comparisons along the F I-sequence and by parametric least-squares fits of Slater integrals to the observed levels. The ionization potential in S VIII is determined to 2 651 899 ± 60 cm -1 and estimated ionization energies are derived for the isoelectronic elements between F I and Ar X. (orig.)

  11. Progress toward inducing immunologic tolerance to factor VIII

    OpenAIRE

    Scott, David W.; Pratt, Kathleen P.; Miao, Carol H.

    2013-01-01

    A major problem in treating hemophilia A patients with therapeutic factor VIII (FVIII) is that 20% to 30% of these patients produce neutralizing anti-FVIII antibodies. These antibodies block (inhibit) the procoagulant function of FVIII and thus are termed “inhibitors.” The currently accepted clinical method to attempt to eliminate inhibitors is immune tolerance induction (ITI) via a protocol requiring intensive FVIII treatment until inhibitor titers drop. Although often successful, ITI is ext...

  12. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  13. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  14. Characterization of five partial deletions of the factor VIII gene

    International Nuclear Information System (INIS)

    Youssoufian, H.; Antonarakis, S.E.; Aronis, S.; Tsiftis, G.; Phillips, D.G.; Kazazian, H.H. Jr.

    1987-01-01

    Hemophilia A is an X-linked disorder of coagulation caused by a deficiency of factor VIII. By using cloned DNA probes, the authors have characterized the following five different partial deletions of the factor VIII gene from a panel of 83 patients with hemophilia A: (i) a 7-kilobase (kb) deletion that eliminates exon 6; (ii) a 2.5-kb deletion that eliminates 5' sequences of exon 14; (iii) a deletion of at least 7 kb that eliminates exons 24 and 25; (iv) a deletion of at least 16 kb that eliminates exons 23-25; and (v) a 5.5-kb deletion that eliminates exon 22. The first four deletions are associated with severe hemophilia A. By contrast, the last deletion is associated with moderate disease, possibly because of in-frame splicing from adjacent exons. None of those patients with partial gene deletions had circulating inhibitors to factor VIII. One deletion occurred de novo in a germ cell of the maternal grandmother, while a second deletion occurred in a germ cell of the maternal grandfather. These observations demonstrate that de novo deletions of X-linked genes can occur in either male or female gametes

  15. Chromogenic Factor VIII Assays for Improved Diagnosis of Hemophilia A.

    Science.gov (United States)

    Rodgers, Susan; Duncan, Elizabeth

    2017-01-01

    Hemophilia A is an inherited bleeding disorder caused by a reduced level of factor VIII coagulant activity (FVIII:C) in blood. Bleeding episodes may occur spontaneously in the severe form of hemophilia or after trauma in the milder forms. It is important that patients are diagnosed correctly, which includes placing them into the correct severity category of the disorder so that appropriate treatment can be given. Diagnosis is made by determination of the amount of FVIII:C in the blood, usually using a one-stage factor VIII:C assay. However, approximately one third of patients with mild or moderate hemophilia will have much lower results by the chromogenic assay, with some of them having normal results by the one-stage assay. The chromogenic factor VIII assay is used in some specialized hemophilia reference centers and is recommended for the diagnosis of mild hemophilia A, as this assay is considered to better reflect the severity status of hemophilia patients than the one-stage assay.

  16. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  17. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  18. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  19. Ehlers-Danlos Syndrome Type VIII: A Rare Cause of Leg Ulcers in Young Patients

    Directory of Open Access Journals (Sweden)

    Sophie Ronceray

    2013-01-01

    Full Text Available Ehlers-Danlos syndrome type VIII (EDS-VIII is a very rare autosomal dominant disease characterized by early-onset periodontitis associated with features of Ehlers-Danlos syndrome. We report a 32-year-old man whose chronic leg ulcer led to the diagnosis of EDS-VIII. He had severe periodontitis with complete loss of permanent teeth and skin fragility with thin skin, atrophic scars, and brownish atrophic pretibial plaques. Leg ulcer is not a prominent feature of EDS-VIII. We suggest adding EDS-VIII to the list of rare diseases accounting for chronic leg ulcers, if this case report prompts others to report leg ulcers associated with EDS-VIII.

  20. [Venous catheter-related infections].

    Science.gov (United States)

    Ferrer, Carmen; Almirante, Benito

    2014-02-01

    Venous catheter-related infections are a problem of particular importance, due to their frequency, morbidity and mortality, and because they are potentially preventable clinical processes. At present, the majority of hospitalized patients and a considerable number of outpatients are carriers of these devices. There has been a remarkable growth of knowledge of the epidemiology of these infections, the most appropriate methodology for diagnosis, the therapeutic and, in particular, the preventive strategies. Multimodal strategies, including educational programs directed at staff and a bundle of simple measures for implementation, applied to high-risk patients have demonstrated great effectiveness for their prevention. In this review the epidemiology, the diagnosis, and the therapeutic and preventive aspects of these infections are updated. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  1. Differential proteolytic activation of factor VIII-von Willebrand factor complex by thrombin

    International Nuclear Information System (INIS)

    Hill-Eubanks, D.C.; Parker, C.G.; Lollar, P.

    1989-01-01

    Blood coagulation factor VIII (fVIII) is a plasma protein that is decreased or absent in hemophilia A. It is isolated as a mixture of heterodimers that contain a variably sized heavy chain and a common light chain. Thrombin catalyzes the activation of fVIII in a reaction that is associated with cleavages in both types of chain. The authors isolated a serine protease from Bothrops jararacussu snake venom that catalyzes thrombin-like heavy-chain cleavage but not light-chain cleavage in porcine fVIII as judged by NaDodSO 4 /PAGE and N-terminal sequence analysis. Using a plasma-free assay of the ability of activated 125 I-fVIII to function as a cofactor in the activation of factor X by factor IXa, they found that fVIII is activated by the venom enzyme. The venom enzyme-activated fVIII was isolated in stable form by cation-exchange HPLC. von Willebrand factor inhibited venom enzyme-activated fVIII but not thrombin-activated fVIII. These results suggest that the binding of fVIII to von Willebrand factor depends on the presence of an intact light chain and that activated fVIII must dissociate from von Willebrand factor to exert its cofactor effect. Thus, proteolytic activation of fVIII-von Willebrand factor complex appears to be differentially regulated by light-chain cleavage to dissociate the complex and heavy-chain cleavage to activate the cofactor function

  2. 40 CFR Appendix Viii to Part 600 - Fuel Economy Label Formats

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Fuel Economy Label Formats VIII... POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Pt. 600, App. VIII Appendix VIII to Part 600—Fuel Economy Label Formats EC01MY92.117 EC01MY92.118 EC01MY92.119 EC01MY92.120...

  3. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  4. Thermoelectrical properties of the compounds ScM{sup VIII}Sb and YM{sup VIII}Sb (M{sup VIII} = Ni, Pd, Pt)

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, J; Probst, U; Richardt, F; Bucher, E [University of Konstanz, PO Box X916, D-78457 Konstanz (Germany)

    2003-02-05

    The research into new materials with good thermoelectric properties has revealed new compounds consisting of metallic elements (Bando Y, Suemitsu T, Takagi K, Tokushima H, Echizen Y, Katoh K, Umeo K, Maeda Y and Takabatake T 2000 J. Alloys Compounds 313 1-6, Ghelani N, Loo S, Chung D, Sportouch S, Nardi S, Kanatzidis M, Hogan T and Nolas G 2000 Mater. Res. Soc. 626 Z8.6.1). The half-Heusler compound ZrNiSn, in particular, shows promising thermoelectric properties and has been studied by many scientists during recent years (Uher C, Hu S, Yang J, Meisner G P and Morelli D T 1997 Proc. ICT'97: 16th Int. Conf. on Thermoelectrics pp 485-8, Romaka L P, Stadnyk Yu V, Goryn A M, Gorelenko Yu K and Skolozdra R V 1997 Proc. ICT'97: 16th Int. Conf. on Thermoelectrics pp 516-19, Hohl H, Ramirez A P, Goldmann C, Ernst G, Woelfing B and Bucher E 1998 J. Phys.: Condens. Matter 11 1697-709, Oestreich J, Kaefer W, Richardt F, Probst U and Bucher E 1999 Proc. 5th European Workshop on Thermoelectrics pp 192-5). In an effort to find new thermoelectric materials, the half-Heusler compounds of the groups ScM{sup VIII}Sb and YM{sup VIII}Sb (M{sup VIII} = Ni, Pd, Pt) were synthesized by arc melting and the thermoelectric properties were examined by standard characterization methods. Doping experiments showed that it is possible to change the electrical properties of the compounds while retaining the half-Heusler structure. Within the two groups, YPtSb showed the best thermoelectrical properties. At a temperature of 400 K the electrical conductivity of YPtSb is 748{omega}{sup -1} cm{sup -1} and the Seebeck coefficient is 116.3{mu}V K{sup -1}. The thermal conductivity at 400 K extrapolated using the Wiedemann-Franz law is 2.87 W K{sup -1} m{sup -1}. This leads to a dimensionless figure of merit of 0.14.

  5. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  6. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  7. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  8. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  9. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  10. Catheter-Associated Urinary Tract Infections

    Science.gov (United States)

    ... Duodenoscope Sampling Method Interim Duodenoscope Culture Method Multiplex Real-Time PCR Detection of KPC & NDM-1 genes Quinolones ... The most commonly used external catheter is a soft flexible sheath that fits over the penis (“condom” ...

  11. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  12. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  13. Factor VIII gene (F8) mutation and risk of inhibitor development in nonsevere hemophilia a

    NARCIS (Netherlands)

    C.L. Eckhardt (Corien); A.S. van Velzen (Alice); M.A.D. Peters (Marjolein); J. Astermark (Jan); P.P. Brons; G. Castaman (Giancarlo); M.H. Cnossen (Marjon); N. Dors (N.); C. Escuriola-Ettingshausen (Carmen); K. Hamulyák (K.); D.P. Hart (Daniel); C.R.M. Hay (Charles R.); S. Haya (Saturnino); W.L. van Heerde; C. Hermans (Cédric); M. Holmström (Margareta); V. Jimenez-Yuste (Victor); R.D. Keenan (Russell); R. Klamroth (Robert); B.A.P. Laros-Van Gorkom (Britta); F.W.G. Leebeek (Frank); R. Liesner (Ri); A. Mäkipernaa (Anne); C. Male (Christoph); E.P. Mauser-Bunschoten (Eveline); M.G. Mazzucconi (Maria); S. McRae (Simon); K. Meijer (K.); M. Mitchell (Michael); M. Morfini (Massimo); M.R. Nijziel (Marten); J. Oldenburg (Jan); K. Peerlinck; P. Petrini (Pia); H. Platokouki (Helena); S.E. Reitter-Pfoertner (Sylvia); E. Santagostino (Elena); P. Schinco (Piercarla); F.J.W. Smiers (Frans); K.D. Siegmund (Kimberly); A. Tagliaferri (Annarita); T.T. Yee (Thynn); P.W. Kamphuisen (Pieter Willem); J.G. van der Bom (Anske); K. Fijnvandraat

    2013-01-01

    textabstractNeutralizing antibodies (inhibitors) toward factor VIII form a severe complication in nonsevere hemophilia A, profoundly aggravating the bleeding pattern. Identification of high-risk patients is hampered by lack of data that take exposure days to therapeutic factor VIII concentrates into

  14. 40 CFR Appendix Viii to Part 266 - Organic Compounds for Which Residues Must Be Analyzed

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Pt. 266, App. VIII Appendix VIII to Part 266... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Organic Compounds for Which Residues...

  15. 40 CFR Appendix Viii to Part 268 - LDR Effective Dates of Injected Prohibited Hazardous Wastes

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false LDR Effective Dates of Injected Prohibited Hazardous Wastes VIII Appendix VIII to Part 268 Protection of Environment ENVIRONMENTAL PROTECTION... to Part 268—LDR Effective Dates of Injected Prohibited Hazardous Wastes National Capacity LDR...

  16. Type VIII collagen is elevated in diseases associated with angiogenesis and vascular remodeling

    DEFF Research Database (Denmark)

    Hansen, N. U. B.; Willumsen, N.; Bülow Sand, Jannie Marie

    2016-01-01

    Objectives Type VIII collagen is involved in angiogenesis and remodeling of arteries. We hypothesized that type VIII collagen was upregulated in diseases associated with vascular remodeling, e.g. pulmonary fibrosis and cancer. In this paper we present the development and validation of a competitive...

  17. Effectiveness of Mind Mapping in English Teaching among VIII Standard Students

    Science.gov (United States)

    Hallen, D.; Sangeetha, N.

    2015-01-01

    The aim of the study is to find out the effectiveness of mind mapping technique over conventional method in teaching English at high school level (VIII), in terms of Control and Experimental group. The sample of the study comprised, 60 VIII Standard students in Tiruchendur Taluk. Mind Maps and Achievement Test (Pretest & Posttest) were…

  18. 4p-5s transitions in YVII, VIII, ZrVIII, IX, NbIX, X and MoX, XI

    International Nuclear Information System (INIS)

    Rahimullah, K.; Chaghtai, M.S.Z.; Khatoon, S.

    1976-01-01

    The spectra of Y VII, VIII, Zr VIII, IX, Nb X and Mo X, XI are studied for the first time and the 1971 analysis of Nb IX is improved. By analyses of the transitions 4s 2 4psup(k)-4s 2 4psup(k-1)5s all the levels of the configurations 4p 3 , 4p 2 5s, 4p 2 and 4p5s are established in the spectra concerned. (Auth.)

  19. Effectiveness of Adaptive Contextual Learning Model of Integrated Science by Integrating Digital Age Literacy on Grade VIII Students

    Science.gov (United States)

    Asrizal, A.; Amran, A.; Ananda, A.; Festiyed, F.

    2018-04-01

    Educational graduates should have good competencies to compete in the 21st century. Integrated learning is a good way to develop competence of students in this century. Besides that, literacy skills are very important for students to get success in their learning and daily life. For this reason, integrated science learning and literacy skills are important in 2013 curriculum. However, integrated science learning and integration of literacy in learning can’t be implemented well. Solution of this problem is to develop adaptive contextual learning model by integrating digital age literacy. The purpose of the research is to determine the effectiveness of adaptive contextual learning model to improve competence of grade VIII students in junior high school. This research is a part of the research and development or R&D. Research design which used in limited field testing was before and after treatment. The research instruments consist of three parts namely test sheet of learning outcome for assessing knowledge competence, observation sheet for assessing attitudes, and performance sheet for assessing skills of students. Data of student’s competence were analyzed by three kinds of analysis, namely descriptive statistics, normality test and homogeneity test, and paired comparison test. From the data analysis result, it can be stated that the implementation of adaptive contextual learning model of integrated science by integrating digital age literacy is effective to improve the knowledge, attitude, and literacy skills competences of grade VIII students in junior high school at 95% confidence level.

  20. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  2. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  3. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  4. Efeitos de humor no poema VIII de Catulo

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio Vasconcellos

    1997-12-01

    Full Text Available Neste artigo apresenta-se uma contribuição ao estudo dos efeitos de humor no poema VIII de Catulo; de fato, além do metro dessa composição e de outros elementos criadores de distanciamento irônico que os estudiosos têm apontado, um outro aspecto de sua forma, ainda pouco percebido, guia a leitura para essa interpretação: o jogo, a maneira de anagrama imperfeito (o “hipograma”, ou, mais precisamente, “criptograma”, de Saussure, com os sons do nome da amada, aparentemente calado. E mais uma das maneiras com que o poeta elabora a jocosa diferença entre o que se diz e o que, sentido e reprimido, deixa-se, porém, transparecer.

  5. Acquired factor VIII inhibitor syndrome: A rare cause of hematuria

    Directory of Open Access Journals (Sweden)

    Muthuvel Seral Kannan

    2015-01-01

    Full Text Available A 50-year-old woman presented with gross hematuria for 1 month. Clinical examinations, laboratory investigations, ultrasound and contrast computed tomography were normal, except anemia. Cystoscopy revealed bloody efflux from the right side. Retrograde pyelogram showed filling defect in the renal pelvis and biopsy was inconclusive. Renal angiogram was normal. She developed ecchymosis on the right thigh and arm with elevated activated partial thromboplastin time. The partial thromboplastin time correction study and Bethesda study confirmed the presence of acquired factor VIII inhibitor (acquired hemophilia. With flexible ureterorenoscopy, the mass in the renal pelvis was removed and its histopathology revealed clotted blood. The patient was subsequently managed with steroids and Factor eight inhibitor bypass activity.

  6. Energies and lifetimes of excited states in copperlike Kr VIII

    International Nuclear Information System (INIS)

    Livingston, A.E.; Curtis, L.J.; Schectman, R.M.; Berry, H.G.

    1980-01-01

    The spectrum of Kr VIII has been observed between 180 and 2000 A by using foil excitation of 2.5--3.5-MeV krypton ions. Twenty new transitions have been classified and eleven new excited-state energies have been determined within the n=4 --7 shells. The ionization potential is derived to be 1 015 800 +- 200 cm -1 . The excited-state energies and fine structures are compared with recent relativistic Hartree-Fock calculations. The 4p-state lifetime has been measured by performing a simultaneous analysis of decay data for the 4p level and for its dominant cascade-repopulating levels. The 4p lifetime is found to be 30% shorter than previously measured values and is in excellent agreement with the result of a recent multiconfiguration Hartree-Fock calculation. The source of the discrepancy between this result and earlier measurements is discussed

  7. A pilot study of chest tube versus pigtail catheter drainage of acute hemothorax in swine.

    Science.gov (United States)

    Russo, Rachel M; Zakaluzny, Scott A; Neff, Lucas P; Grayson, J Kevin; Hight, Rachel A; Galante, Joseph M; Shatz, David V

    2015-12-01

    Evacuation of traumatic hemothorax (HTx) is typically accomplished with large-bore (28-40 Fr) chest tubes, often resulting in patient discomfort. Management of HTx with smaller (14 Fr) pigtail catheters has not been widely adopted because of concerns about tube occlusion and blood evacuation rates. We compared pigtail catheters with chest tubes for the drainage of acute HTx in a swine model. Six Yorkshire cross-bred swine (44-54 kg) were anesthetized, instrumented, and mechanically ventilated. A 32 Fr chest tube was placed in one randomly assigned hemithorax; a 14 Fr pigtail catheter was placed in the other. Each was connected to a chest drainage system at -20 cm H2O suction and clamped. Over 15 minutes, 1,500 mL of arterial blood was withdrawn via femoral artery catheters. Seven hundred fifty milliliters of the withdrawn blood was instilled into each pleural space, and fluid resuscitation with colloid was initiated. The chest drains were then unclamped. Output from each drain was measured every minute for 5 minutes and then every 5 minutes for 40 minutes. The swine were euthanized, and thoracotomies were performed to quantify the volume of blood remaining in each pleural space and to examine the position of each tube. Blood drainage was more rapid from the chest tube during the first 3 minutes compared with the pigtail catheter (348 ± 109 mL/min vs. 176 ± 53 mL/min), but this difference was not statistically significant (p = 0.19). Thereafter, the rates of drainage between the two tubes were not substantially different. The chest tube drained a higher total percentage of the blood from the chest (87.3% vs. 70.3%), but this difference did not reach statistical significance (p = 0.21). We found no statistically significant difference in the volume of blood drained by a 14 Fr pigtail catheter compared with a 32 Fr chest tube.

  8. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  9. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  10. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  11. Navigation of guidewires and catheters in the body during intervention procedures : A review of computer-based models

    NARCIS (Netherlands)

    Sharei Amarghan, H.; Alderliesten, Tanja; van den Dobbelsteen, J.J.; Dankelman, J.

    2018-01-01

    Guidewires and catheters are used during minimally invasive interventional procedures to traverse in vascular system and access the desired position. Computer models are increasingly being used to predict the behavior of these instruments. This information can be used to choose the right

  12. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  13. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially

  14. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  15. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  16. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  17. Urinary catheterization diary – A useful tool in tracking causes of non-deflating Foley catheter

    Directory of Open Access Journals (Sweden)

    C.O. Okorie

    2015-06-01

    Conclusions: Most urinary catheters marketed in developing countries are unidentifiable after unpacking. A catheterization diary is a useful tool for solving catheter-related problems, and its application in health-care facilities should be encouraged. Companies marketing Foley catheters should print the catheter name on both the catheter packaging and on the catheter itself.

  18. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  19. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  20. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  1. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  2. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  3. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  4. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  5. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  7. OCCASIONAL REVIEW 'Map and zap' - electrode catheter ...

    African Journals Online (AJOL)

    Where does this leave surgical treatment of WPW syndrome? Despite the high success rates reported, ·it is acknowledged that not all patients can be successfully treated by catheter ablation. The treatment of those with multiple accessory pathways and associated defects such as Ebstein's anomaly of the tricuspid valve is ...

  8. Thoracoscopic retrieval of a fractured thoracentesis catheter.

    Science.gov (United States)

    Albrink, M H; McAllister, E W

    1994-08-01

    With the resurgence of laparoscopic surgical procedures, thorascopic procedures have followed close behind. Many procedures which in the past have required formal thoracotomy may now be performed via less invasive methods. Presented herein is a report and description of thoracoscopic retrieval of a fractured thoracentesis catheter.

  9. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  10. Time Transfer Experiment by TCE on the ETS-VIII Satellite

    National Research Council Canada - National Science Library

    Nakagawa, Fumimaru; Takahashi, Yasuhiro; Amagai, Jun; Tabuchi, Ryo; Hama, Shin'ichi; Hosokawa, Mizuhiko

    2007-01-01

    .... At NICT, we developed Time Comparison Equipment (TCE) both onboard ETS-VIII and in the Earth station for precise time transfer between the atomic clocks on the satellite and a ground reference clock...

  11. Class VIII Medical Materiel Controls in the U.S. European Command

    National Research Council Canada - National Science Library

    1991-01-01

    .... Class VIII medical materiel inventories are maintained as part of the U.S. war reserve stocks to ensure military readiness and to provide needed health care during wartime or contingencies. The U.S...

  12. Mechanistic aspects of Os(VIII) catalysed oxidation of loop diuretic ...

    Indian Academy of Sciences (India)

    furosemide by Ag(III) periodate complex in aqueous alkaline medium. SHWETA J .... Os(VIII) catalysed DPA oxidation, the order in [OH. −. ] ... Victoria-3170, Australia) connected to a rapid ..... follows. The furosemide, periodate and hydroxide ion.

  13. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  14. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  15. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  16. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. Spectra of the W VIII isoelectronic sequence: III. Re IX

    International Nuclear Information System (INIS)

    Ryabtsev, A N; Kononov, E Ya; Kildiyarova, R R; Tchang-Brillet, W-Ü L; Wyart, J-F; Champion, N; Blaess, C

    2015-01-01

    Rhenium spectra excited in vacuum spark sources of different setups and electric circuits were recorded on two high resolution vacuum spectrographs: a 10 m normal incidence spectrograph with a 3600 l mm −1 grating in the Meudon Observatory and a 3 m grazing incidence spectrograph with a 3600 l mm −1 grating in the Institute of Spectroscopy in Troitsk. A total of 112 lines in the region 146–244 Å were identified as transitions from the interacting excited even configurations 4f 12 5s 2 5p 6 5d + 4f 13 5s 2 5p 5 (5d + 6s) + 4f 14 5s 2 5p 4 (5d + 6s) to the low-lying odd configurations 4f 13 5s 2 5p 6 and 4f 14 5s 2 5p 5 . A change of the ground configuration from 4f 13 5s 2 5p 6 to 4f 14 5s 2 5p 5 in a comparison with the previous spectra of the isoelectronic sequence Hf VI–W VIII was observed. Fine structure splittings and relative positions of the odd terms were established, and 83 levels of the excited even configurations were found. (paper)

  19. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  20. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  1. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  2. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  3. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  4. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  5. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  6. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  7. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  8. Percutaneous catheter drainage of tuberculous psoas abscesses

    International Nuclear Information System (INIS)

    Pombo, F.; Martin-Egana, R.; Cela, A.; Diaz, J.L.; Linares-Mondejar, P.; Freire, M.

    1993-01-01

    Six patients with 7 tuberculous psoas or ilio-psoas abscesses were treated by CT-guided catheter drainage and chemotherapy. The abscesses (5 unilateral and 1 bilateral) were completely drained using a posterior or lateral approach. The abscess volume was 70 to 700 ml (mean 300 ml) and the duration of drainage 5 to 11 days (mean 7 days). Immediate local symptomatic improvement was achieved in all patients, and there were no procedural complications. CT follow-up at 3 to 9 months showed normalization in 5 patients, 2 of whom are still in medical therapy. One patient, who did not take the medication regularly, had a recurrent abscess requiring new catheter drainage after which the fluid collection disappeared. Percutaneous drainage represents an efficient and attractive alternative to surgical drainage as a supplement to medical therapy in the management of patients with large tuberculous psoas abscesses. (orig.)

  9. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  10. Lights, camera and action in the implementation of central venous catheter dressing1

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters. PMID:26626011

  11. Lights, camera and action in the implementation of central venous catheter dressing.

    Science.gov (United States)

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    To develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. This is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. The items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. The educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  12. Lights, camera and action in the implementation of central venous catheter dressing

    Directory of Open Access Journals (Sweden)

    Maria Verônica Ferrareze Ferreira

    2015-12-01

    Full Text Available Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  13. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  14. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  15. Retrograde prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    The authors performed retrograde prostatic urethroplasty in 18 patients using a 25-mm urethroplasty balloon catheter. The procedure was performed on an outpatient basis under local anesthesia. Voiding cystourethrography, retrograde urethrography, rectal US, and MRE imaging were performed before and immediately after the procedure and at 2 weeks and 3, 6, 12, and 18 months. Long-term results at 18 months and possible clinical implications are discussed

  16. Agnostic stacking of intergalactic doublet absorption: measuring the Ne VIII population

    Science.gov (United States)

    Frank, Stephan; Pieri, Matthew M.; Mathur, Smita; Danforth, Charles W.; Shull, J. Michael

    2018-05-01

    We present a blind search for doublet intergalactic metal absorption with a method dubbed `agnostic stacking'. Using a forward-modelling framework, we combine this with direct detections in the literature to measure the overall metal population. We apply this novel approach to the search for Ne VIII absorption in a set of 26 high-quality COS spectra. We probe to an unprecedented low limit of log N>12.3 at 0.47≤z ≤1.34 over a path-length Δz = 7.36. This method selects apparent absorption without requiring knowledge of its source. Stacking this mixed population dilutes doublet features in composite spectra in a deterministic manner, allowing us to measure the proportion corresponding to Ne VIII absorption. We stack potential Ne VIII absorption in two regimes: absorption too weak to be significant in direct line studies (12.3 13.7). We do not detect Ne VIII absorption in either regime. Combining our measurements with direct detections, we find that the Ne VIII population is reproduced with a power-law column density distribution function with slope β = -1.86 ^{+0.18 }_{ -0.26} and normalization log f_{13.7} = -13.99 ^{+0.20 }_{ -0.23}, leading to an incidence rate of strong Ne VIII absorbers dn/dz =1.38 ^{+0.97 }_{ -0.82}. We infer a cosmic mass density for Ne VIII gas with 12.3 value significantly lower that than predicted by recent simulations. We translate this density into an estimate of the baryon density Ωb ≈ 1.8 × 10-3, constituting 4 per cent of the total baryonic mass.

  17. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  18. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  19. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  20. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  1. On existence and properties of plutonium(VIII) derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Kiselev, Yu.M.; Dolzhenko, V.D.; Ermilov, A.Yu. [Moscow State Univ. (Russian Federation). Chemistry Dept.; Nikonov, M.V.; Myasoedov, B.F. [Russian Academy of Science, Moscow (Russian Federation). Inst. of Geochemistry and Analytical Chemistry; Tananaev, I.G. [Russian Academy of Science, Moscow (Russian Federation). Inst. of Physical Chemistry and Electrochemistry

    2014-04-01

    The existence of Pu(VIII) was shown in alkaline solutions and in nonpolar solvents (CCl{sub 4} and CHCl{sub 3}) on the ground of such experimental facts like extraction of plutonium species, obtained by means of ozonization of Pu(VI) alkaline solutions into CCl{sub 4} and CHCl{sub 3}; volatility of Pu compounds out of aqueous alkaline solutions, and the mentioned solvents. The product of interaction between PuO{sub 3}.0.8H{sub 2}O and XeF{sub 2} in CCl{sub 4} and CHCl{sub 3} was of the same chemical form for both cases and identical with the form of the product of volatility of Pu out of these organic solutions. The electronic absorbance spectra of these products in CCl{sub 4} and CHCl{sub 3} were fairly similar to the ones for OsO{sub 4} and RuO{sub 4}. The band of absorption in these spectra with the maximum at 332 nm corresponds to the charge transfer of metal-ligand type [π(O)→Pu], as the value of molar extinction coefficient e was found to be higher than 2 x 10{sup 3} L/mole cm. A satisfactory agreement between the energies for the transitions of PuO{sub 4} molecule designed by X{sub α}-SW method and experimental data was observed. A similar accordance was observed for the designed vibration frequency (DFT-method) with the one found as result of analysis of the vibration structure of the experimental spectra. (orig.)

  2. Current status of endovascular catheter robotics.

    Science.gov (United States)

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  3. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  4. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  5. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  6. Myosin VIII regulates protonemal patterning and developmental timing in the moss Physcomitrella patens.

    Science.gov (United States)

    Wu, Shu-Zon; Ritchie, Julie A; Pan, Ai-Hong; Quatrano, Ralph S; Bezanilla, Magdalena

    2011-09-01

    Plants have two classes of myosins. While recent work has focused on class XI myosins showing that myosin XI is responsible for organelle motility and cytoplasmic streaming, much less is known about the role of myosin VIII in plant growth and development. We have used a combination of RNAi and insertional knockouts to probe myosin VIII function in the moss Physcomitrella patens. We isolated Δmyo8ABCDE plants demonstrating that myosin VIII is not required for plant viability. However, myosin VIII mutants are smaller than wild-type plants in part due to a defect in cell size. Additionally, Δmyo8ABCDE plants produce more side branches and form gametophores much earlier than wild-type plants. In the absence of nutrient media, Δmyo8ABCDE plants exhibit significant protonemal patterning defects, including highly curved protonemal filaments, morphologically defective side branches, as well as an increase in the number of branches. Exogenous auxin partially rescues protonemal defects in Δmyo8ABCDE plants grown in the absence of nutrients. This result, together with defects in protonemal branching, smaller caulonemal cells, and accelerated development in the Δmyo8ABCDE plants, suggests that myosin VIII is involved in hormone homeostasis in P. patens.

  7. The F309S mutation increases factor VIII secretion in human cell line

    Directory of Open Access Journals (Sweden)

    Daianne Maciely Carvalho Fantacini

    2016-06-01

    Full Text Available ABSTRACT OBJECTIVES: The capacity of a human cell line to secrete recombinant factor VIII with a F309S point mutation was investigated, as was the effect of the addition of chemical chaperones (betaine and sodium-4-phenylbutyrate on the secretion of factor VIII. METHODS: This work used a vector with a F309S mutation in the A1 domain to investigate FVIII production in the HEK 293 human cell line. Factor VIII activity was measured by chromogenic assay. Furthermore, the effects of chemical drugs on the culture were evaluated. RESULTS: The addition of the F309S mutation to a previously described FVIII variant increased FVIII secretion by 4.5 fold. Moreover, the addition of betaine or sodium-4-phenylbutyrate increased the secretion rate of FVIIIΔB proteins in HEK 293 cells, but the same effect was not seen for FVIIIΔB-F309S indicating that all the recombinant protein produced had been efficiently secreted. CONCLUSION: Bioengineering factor VIII expressed in human cells may lead to an efficient production of recombinant factor VIII and contribute toward low-cost coagulation factor replacement therapy for hemophilia A. FVIII-F309S produced in human cells can be effective in vivo.

  8. Practical experience and lessons learned through implementation of Appendix VIII performance demonstration requirements

    International Nuclear Information System (INIS)

    Ashwin, P.J.; Becker, F.L.; Latiolais, C.L.; Spanner, J.C.

    1996-01-01

    To provide the US nuclear industry with a uniform implementation of the Performance Demonstration requirements within the 1989 edition of ASME Section XI, Appendix VIII, representatives from all US nuclear utilities formed the Performance Demonstration Initiative (PDI). The PDI recognized the potential benefits that Appendix VIII offered the nuclear industry and initiated a proactive approach to implement the requirements. In doing so it was expected that performance demonstration of ultrasonic examination procedures would allow for improvement in the efficiency and credibility of inservice inspection to be realized. Explicit within the performance demonstration requirements of Appendix VIII is the need for a Performance Demonstration Administrator, a difficult requirement to fulfill. Not only must the administrator exhibit the attributes of understanding the demonstration requirements, but also have solid technical knowledge, integrity and be able to interface with the industry at all levels, from operations to regulatory. For the nuclear industry, the EPRI NDE Center is an obvious choice to fulfill this position. This paper provides a brief background of the PDI, a nuclear industry-wide initiative to implement the performance demonstration requirements of Appendix VIII. Even though the consensus approach adopted by the PDI is discussed, the paper's primary objective is to provide examples of the lessons learned by the Center through the specific requirements of Appendix VIII

  9. Diagnostic accuracy study of a factor VIII ELISA for detection of factor VIII antibodies in congenital and acquired haemophilia A.

    Science.gov (United States)

    Batty, Paul; Moore, Gary W; Platton, Sean; Maloney, James C; Palmer, Ben; Bowles, Louise; Pasi, K John; Rangarajan, Savita; Hart, Daniel P

    2015-10-01

    Antibody formation to factor VIII (FVIII) remains the greatest clinical and diagnostic challenge to the haemophilia-treating physician. Current guidance for testing for inhibitory FVIII antibodies (inhibitors) recommends the functional Nijmegen-Bethesda assay (NBA). A FVIII ELISA offers a complementary, immunological approach for FVIII antibody testing. It was the aim of this study to retrospectively evaluate the performance of a FVIII ELISA (index) for detection of FVIII antibodies, compared with the NBA (reference). All samples sent for routine FVIII antibody testing at two haemophilia Comprehensive Care Centres, were tested in parallel using the NBA and a solid-phase, indirect FVIII ELISA kit (Immucor). A total of 497 samples from 239 patients (severe haemophilia A=140, non-severe haemophilia A=85, acquired haemophilia A=14) were available for analysis. Sixty-three samples tested positive by the NBA (prevalence 12.7%, 95% confidence interval [CI], 9.9-15.9 %), with a median inhibitor titre of 1.2 BU/ml (range 0.7-978.0). The FVIII ELISA demonstrated a specificity of 94.0% (95%CI, 91.3-96.0), sensitivity of 77.8% (95%CI, 65.5-87.3), negative predictive value of 96.7% (95%CI, 94.5-98.2), positive predictive value 65.3% (95%CI, 53.5-76.0), negative likelihood ratio 0.2 (95%CI, 0.1-0.4), positive likelihood ratio 13.0 (95%CI, 8.7-19.3) and a diagnostic odds ratio of 54.9 (95%CI, 27.0-112.0). Strong positive correlation (r=0.77, pNBA (log adjusted) and FVIII ELISA optical density. In conclusion, FVIII ELISA offers a simple, specific, surveillance method enabling batch testing of non-urgent samples for the presence of FVIII antibodies.

  10. Embolization of brain arteriovenous malformations using tracker catheter

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Son, Mi Young; Jang, Jae Chun; Hwang, Mi Soo; Park, Bok Hwan

    1990-01-01

    With the recent advance in micro catheters, steerable guide wires, balloons, embolic materials and digital subtraction angiography (DSA), as well as technical refinements in endovascular surgery, there has been a revolution in therapeutic strategies for cerebral arteriovenous malformations (AVMs). We have performed super selective angiography and embolization with Tracker micro catheter about 12 cases of brain AVMs for therapeutic and preoperative aims. This micro catheter and guide wire provided high selectivity of feeding artery, greater maneuverability and useful for deliver various embolus materials

  11. Successful Use of Modified Suprapubic Catheter to Rescue Prostatorectal Fistula

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chiu

    2008-06-01

    Full Text Available Prostatorectal fistula is a complication following radiotherapy. It remains a clinical challenge to treat because most patients experience a poor quality of life. This case report discusses a modified suprapubic catheter for use in a patient with a prostatorectal fistula that developed after radiotherapy for localized prostate cancer. It is an inexpensive, easily available, and more patient-tolerable catheter that improves quality of life. Herein, we describe the development of this catheter.

  12. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  13. Hemodialysis in a patient with severe hemophilia A and factor VIII inhibitor.

    Science.gov (United States)

    Gopalakrishnan, Natarajan; Usha, Thiruvengadam; Thopalan, Balasubramaniyan; Dhanapriya, Jeyachandran; Dineshkumar, Thanigachalam; Thirumalvalavan, Kaliaperumal; Sakthirajan, Ramanathan

    2016-10-01

    Hemophilia A is a hereditary X-linked recessive disease caused by mutations in the gene encoding factor VIII (FVIII), occurring in 1 out of 10,000 persons. Life expectancy and quality of life have dramatically improved recently in patients with hemophilia. Chronic kidney disease and need for renal replacement therapy in these patients are rare. The development of inhibitors to FVIII is the most serious complication of hemophilia and makes treatment of bleeds very challenging. We describe here a 28-year-old male patient with severe hemophilia A with presence of factor VIII inhibitor, who had end stage renal disease. Central venous access device was inserted along with infusion of factor eight inhibitor bypass activity before and after the procedure. He is currently on thrice weekly hemodialysis and doing well for 6 months without bleeding episodes. To our knowledge, hemophilia A with factor VIII inhibitor managed with hemodialysis has not been reported so far. © 2016 International Society for Hemodialysis.

  14. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  15. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Spectrophotometric determination of hydrogen peroxide with osmium(VIII) and m-carboxyphenylfluorone.

    Science.gov (United States)

    Hoshino, Mitsuru; Kamino, Shinichiro; Doi, Mitsunobu; Takada, Shingo; Mitani, Shota; Yanagihara, Rika; Asano, Mamiko; Yamaguchi, Takako; Fujita, Yoshikazu

    2014-01-03

    Spectrophotometric determination of hydrogen peroxide was accomplished with osmium(VIII) and m-carboxyphenylfluorone (MCPF) in the presence of cetyltrimethylammonium chloride (CTAC). In the determination of hydrogen peroxide based on the fading of the color of osmium(VIII)-MCPF complex, Beer's law was obeyed in the range 20-406 ng mL(-1), with an effective molar absorption coefficient (at 580 nm) of 5.21×10(4) L mol(-1) cm(-1) and a relative standard deviation of 0.33% (n=6). Further, we performed the characterization of MCPF and obtained the crystal structure. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Lacerations to Zones VIII and IX: It Is Not Just a Tendon Injury

    Directory of Open Access Journals (Sweden)

    Charla R. Fischer

    2011-01-01

    Full Text Available Extensor tendon injuries are widely believed to be straightforward problems that are relatively simple to manage. However, these injuries can be complex and demand a thorough understanding of anatomy to achieve the best functional outcomes. When lacerations occur in the forearm as in Zones VIII and IX injury, the repair of the extensor tendon and muscle, and posterior interosseous nerve (PIN is often challenging. A review of the literature shows little guidance and attention for these injuries. We present four patients with injuries to Zones VIII and IX as well as a review of surgical technique, postoperative rehabilitation, and pearls that may be of benefit to those managing these injuries.

  18. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  19. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  20. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  1. Implantable electrolyte conductance-based pressure sensing catheter, II. Device construction and testing.

    Science.gov (United States)

    Tan, Robert; Benharash, Peyman; Schulam, Peter; Schmidt, Jacob J

    2013-12-01

    Direct measurements of arterial blood pressure most commonly use bulky external instrumentation containing a pressure transducer connected to an ex vivo fluid-filled arterial line, which is subject to several sensing artifacts. In situ blood pressure sensors, typically solid state piezoresistive, capacitive, and interferometric sensors, are unaffected by these artifacts, but can be expensive to produce and miniaturize. We have developed an alternative approach to blood pressure measurement based on deformation of an elastic tube filled with electrolyte solution. Simple measurement of the electrical conductance of this solution as the tube dimensions change allows determination of the external pressure. The sensor is made from inexpensive materials and its miniaturization is straightforward. In vitro static testing of initial sensor prototypes mounted on a catheter tip showed a linear response with applied pressure and a resolution of 1 mmHg. In vivo sensing followed catheterization of the sensor into the femoral artery of a porcine model through a 7F catheter port. The sensor performed comparably to a commercial pressure transducer also connected to the catheter port. Due to its scalability and cost, this sensor has the potential for use in a range of pressure sensing applications, such as measurement of intracranial, spinal, or interstitial pressures.

  2. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  3. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  5. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  6. Comparison of Foley catheter and prostaglandin E2 tablets for the induction of labor at term

    Directory of Open Access Journals (Sweden)

    Ana Daneva Markova

    2013-12-01

    Full Text Available The aim of the paper was to assess success rates and associated maternal and fetal risks, to determine the different methods of induction for labor at term, compare induction with Foley catheter and induction with naturally occurring prostaglandin E2 (PGE2 tablets in women with gestational age at term. Two hundred and twelve women at term were included into the study, one group with Foley catheter, the second group with PGE2 tablets, with a maximum of two doses. The primary outcome measures were the admission-to-delivery interval and the induction-to-delivery interval. Secondary outcomes included cesarean section rate, mode of delivery, and maternal and neonatal safety outcome. Results were calculated by applying the Fisher’s exact test, c2-test, t-test and calculating the P-value using an alpha level of 0.05 for Type I errors. The mean time from admission to delivery was 13.53h in the Foley catheter group and 12.30h in the PGE2 group (P=0.090. The induction-to-delivery interval was also comparable between the groups (10.75h vs 9.37h, while the cesarean section rate did not differ significantly between them (7.61% vs 15.30%. More women in the misoprostol group had an instrumental delivery (12.38% vs 2.94%. The only significant difference in neonatal outcome was a larger number of babies born with Apgar score < 7 at 1 min in the Foley group. Maternal outcomes were not significantly different, except for a higher number of digital examinations in the Foley group. Foley catheter is equally efficacious in labor induction and demonstrates a similar fetal and maternal safety profile to PGE2.

  7. Prolonged use of indwelling urinary catheter following acute urinary ...

    African Journals Online (AJOL)

    J.O. Bello

    prolonged use of urinary catheters following acute urinary retention secondary to benign prostate enlarge- ment (BPE) and urethral ... indwelling urinary catheter for >3 months following acute urinary retention due to BPE or USD. The study .... the major health-care financing strategy in Nigeria and accounts for more than ...

  8. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  9. Management of retained encrusted urethral catheter with extracorporeal shockwave lithotripsy

    Directory of Open Access Journals (Sweden)

    Sameh Anwar Kunzman

    2002-01-01

    Full Text Available We report a case of non-deflating heavily encrusted Foley catheter successfully removed by extracorporeal shockwave lithotripsy (ESWL. To our knowledge this is the first case of using ESWL to remove encrusted foley catheter retained in the bladder.

  10. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  11. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  12. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    Urinary bladder catheter encrustations are known complications of long-term urinary catheterisation, which is commonly seen in clinical practice. These encrustations can impede deflation of the balloon and therefore cause problems in the removal of the catheter. The options in managing an encrusted and incarcerated ...

  13. Detection of electrophysiology catheters in noisy fluoroscopy images

    NARCIS (Netherlands)

    Franken, E.M.; Rongen, P.M.J.; Almsick, van M.A.; Haar Romenij, ter B.M.

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust

  14. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Background Peritoneal dialysis catheter (PDC) failure still remains a common clinical problem in pediatric patients despite advancements in catheter placement and dialysis techniques. Our aim was to determine the risk factors that may lead to PDC failure, especially those factors that could be potentially modified to ...

  15. Unusual migration of ventriculo peritoneal distal catheter into vagina

    Directory of Open Access Journals (Sweden)

    Sghavamedin Tavallaee

    2015-04-01

    Full Text Available VP shunt is one of the most popular methods for ICP reduction and treatment of hydrocephalus. Various complications of this method are not uncommon such as shunt malfunction, infection and unusual migration of distal catheter. I present a case of migration of the peritoneal catheter out of the vagina.

  16. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  17. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  18. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... prevented. ... blood from both the catheter and a peripheral site, may ... Given the important role of cutaneous microflora in the ... valvular heart disease (especially prosthetic valves) and ... be explained by high arterial flow around the catheter, ... vena cava or right atrium via the cephalic and basilar veins of ...

  19. Predicting success of catheter drainage in infected necrotizing pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; Van Brunschot, Sandra; Bakker, Olaf J.; Ali, Usama Ahmed; Van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; Van Santvoort, Hjalmar C.

    2016-01-01

    Introduction: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. Methods: This was a

  20. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; van Brunschot, Sandra; Bakker, Olaf J.; Ahmed Ali, Usama; van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; van Santvoort, Hjalmar C.

    2016-01-01

    At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. This was a post hoc analysis of 130

  1. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, R.A.; Bollen, T.L.; Brunschot, S. van; Bakker, O.J.; Ali, U. Ahmed; Goor, H. van; Boermeester, M.A.; Gooszen, H.G.; Besselink, M.G.; Santvoort, H.C. van

    2016-01-01

    INTRODUCTION: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. METHODS: This was a

  2. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    2010-11-25

    Nov 25, 2010 ... cases of extraluminal encrusted urethral catheters. Extracorporeal shock wave lithotripsy (ESWL) has been utilised in the treatment of the bladder stones. Borrowing this principle, Kunzman et al. (12) has even used ESWL to fragment the stone-like encrustation over the retained Foley catheter balloon.

  3. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  4. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  5. Innovating urinary catheter design: An introduction to the engineering challenge.

    Science.gov (United States)

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  6. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  7. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  9. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  10. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  11. Analysis of mutations in the entire coding sequence of the factor VIII gene

    Energy Technology Data Exchange (ETDEWEB)

    Bidichadani, S.I.; Lanyon, W.G.; Connor, J.M. [Glascow Univ. (United Kingdom)] [and others

    1994-09-01

    Hemophilia A is a common X-linked recessive disorder of bleeding caused by deleterious mutations in the gene for clotting factor VIII. The large size of the factor VIII gene, the high frequency of de novo mutations and its tissue-specific expression complicate the detection of mutations. We have used a combination of RT-PCR of ectopic factor VIII transcripts and genomic DNA-PCRs to amplify the entire essential sequence of the factor VIII gene. This is followed by chemical mismatch cleavage analysis and direct sequencing in order to facilitate a comprehensive search for mutations. We describe the characterization of nine potentially pathogenic mutations, six of which are novel. In each case, a correlation of the genotype with the observed phenotype is presented. In order to evaluate the pathogenicity of the five missense mutations detected, we have analyzed them for evolutionary sequence conservation and for their involvement of sequence motifs catalogued in the PROSITE database of protein sites and patterns.

  12. Idiopathic factor VIII inhibitor autoantibody in a man presented after accident.

    NARCIS (Netherlands)

    Mansouritorghabeh, H.; Lak, M.; Heerde, W.L. van

    2009-01-01

    Acquired hemophilia A is a rare but severe autoimmune bleeding disorder caused by autoantibodies against factor VIII activity and is a potentially life-threatening hemorrhagic disorder. The incidence of acquired hemophilia A has been estimated as 1.48 cases per million per year. The overall rate of

  13. Factor VIII and von Willebrand factor co-delivery by endothelial cells

    NARCIS (Netherlands)

    Bouwens, E.A.M.|info:eu-repo/dai/nl/314061894

    2011-01-01

    A defect in coagulation factor VIII (FVIII) results in the inherited bleeding disorder hemophilia A. Current treatment of hemophilia A is hampered by the need of frequent administration of costly FVIII products. Therefore gene therapy is an attractive alternative for protein replacement to treat

  14. Living in a physical world VIII. Gravity and life in water

    Indian Academy of Sciences (India)

    2006-07-31

    Jul 31, 2006 ... Home; Journals; Journal of Biosciences; Volume 31; Issue 3. Living in a physical world VIII. Gravity and life in water. Steven Vogel. Series Volume 31 Issue 3 September 2006 pp 309-322. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/jbsc/031/03/0309-0322 ...

  15. Visualizing the Life and Legacy of Henry VIII: Guiding Students with Eight Types of Graphic Organizers

    Science.gov (United States)

    Gallavan, Nancy P.; Kottler, Ellen

    2010-01-01

    Delving into the life and legacy of Henry VIII is both complex and captivating. People seem compelled to learn more abut his critical contributions and controversial conduct that range from the significant to the scandalous. Reflecting on the history of the world would be incomplete without investigating the events and escapades associated with…

  16. Quark matter coupled to domain walls in Bianchi types II, VIII and IX ...

    Indian Academy of Sciences (India)

    In this study of Bianchi types II, VIII and IX Universes, quark matter coupled to domain walls in the ... The self-bound state appears to be at ρ ... The observations suggest that the Hubble expansion of the Universe ... Taking motivation from.

  17. Storage and regulated secretion of factor VIII in blood outgrowth endothelial cells

    NARCIS (Netherlands)

    van den Biggelaar, M.; Bouwens, E.A.M.; Kootstra, N.A.; Hebbel, R.P.; Voorberg, J.; Mertens, K.

    2009-01-01

    Background Gene therapy provides an attractive alternative for protein replacement therapy in hemophilia A patients. Recent studies have shown the potential benefit of directing factor (F)VIII gene delivery to cells that also express its natural carrier protein von Willebrand factor (VWF). In this

  18. Storage and regulated secretion of factor VIII in blood outgrowth endothelial cells

    NARCIS (Netherlands)

    van den Biggelaar, Maartje; Bouwens, Eveline A. M.; Kootstra, Neeltje A.; Hebbel, Robert P.; Voorberg, Jan; Mertens, Koen

    2009-01-01

    Gene therapy provides an attractive alternative for protein replacement therapy in hemophilia A patients. Recent studies have shown the potential benefit of directing factor (F)VIII gene delivery to cells that also express its natural carrier protein von Willebrand factor (VWF). In this study, we

  19. Successful Pregnancy in a Patient with Combined Deficiency of Factor V and Factor VIII.

    Science.gov (United States)

    El Adib, Ahmed Ghassan; Majdi, Farah; Dilai, Mohamed Othmane; Asmouki, Hamid; Bassir, Ahlam; Harou, Karam; Soumani, Abderraouf; Younous, Said; Mahmal, Lahoucine

    2014-01-01

    Inherited combined factor V and factor VIII deficiency (F5F8D) is autosomal recessive transmission disorder. Epistaxis, postsurgical bleeding, and menorrhagia are the most common symptoms. The risk of miscarriage and placental abruption is consequent. We report a case of successful pregnancy in a patient with F5F8D. 20-year-old woman, born of consanguineous parents, third gestate, first parity, two miscarriages, admitted for child birth of a spontaneous pregnancy estimated at 38 weeks and was diagnosed with F5F8D. At admission, patient was hemodynamically stable, with good obstetric conditions. The biologic results showed low levels of PT (52%), factor V (7%), and factor VIII (5%), and the activated partial thromboplastin time was prolonged (68,6%). Parturient was admitted in intensive care unit, maternal and fetal monitoring was performed. Fresh frozen plasma (FFP) and factor VIII concentrates were perfused at the induction of labor. Analgesia used fentanyl titration. The delivery gave birth to a newborn male, with Apgar 10/10 and 3000 g. The puerperium was simple without any important bleeding. Laboratory tests for the newborn were acceptable. Little literature is available on this subject and there are no guidelines available concerning pregnancy; we chose to prescribe a combination of factor VIII concentrate and FFP in pre-, per- and postpartum. The same protocol was successfully used in a patient before dental extraction and prostatectomy. Vaginal delivery is possible, as our case. Management by multidisciplinary team is recommended.

  20. Glioneuronal Heterotopia Presenting As a Cerebellopontine angle Tumor of the cranial Nerve VIII, Case Report.

    Science.gov (United States)

    Peris-Celda, M; Giannini, C; Diehn, F E; Eckel, L J; Neff, B A; Van Gompel, J J

    2018-04-03

    Vestibular schwannomas and meningiomas account for the great majority of lesions arising in the cerebellopontine angle (CPA). In this report, we present a case of glioneuronal heterotopia, also known as glioneuronal hamartoma, arising from the VIII cranial nerve, which is an extremely uncommon lesion. Important radiologic and surgical aspects are reviewed, which may help in early recognition and intraoperative decision making when these lesions are encountered. A healthy 29-year-old female presented with intermittent right facial numbness. Magnetic resonance imaging (MRI) showed an incidental minimally enhancing cerebellopontine angle lesion on the right VII-VIII cranial nerve complex. The patient declined serial observation and opted for operative intervention for resection. Intraoperatively, the lesion resembled neural tissue and was continuous with the VIII cranial nerve. Pathological analysis demonstrated mature glioneuronal tissue consistent with hamartomatous brain tissue. The patient maintained normal hearing and facial nerve function after surgery. Radiologic, surgical and pathological characteristics are described. Ectopic glioneuronal tissue of the VIII cranial nerve is a rare non-neoplastic lesion, and should be considered in the differential diagnosis of unusual appearing intracanalicular and cerebellopontine angle lesions. The congenital and benign nature of this entity makes observation a valid option for these cases, although they are so infrequent that they are often presumptively managed as vestibular schwannomas. Attempts to radically resect these lesions may result in higher rates of hearing loss or facial palsy due to their continuity with the cranial nerves. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Home therapy with continuous infusion of factor VIII after minor surgery or serious haemorrhage.

    Science.gov (United States)

    Varon, D; Schulman, S; Bashari, D; Martinowitz, U

    1996-10-01

    Administration of factor VIII (F VIII) concentrates by continuous infusion is now routinely used at several haemophilia centers but almost exclusively for hospitalized patients. We evaluated various aspects of home therapy with continuous infusion of an immunoaffinity purified F VIII concentrate (Monoclate P®, Armour) in patients who would normally have been treated with high doses in bolus injections or with continuous infusion as in-patients. Twenty haemophilia A patients, eight after minor surgery and 12 for serious haemorrhage, received continuous infusion with undiluted F VIII by a minipump for a mean of 0.9 days in the hospital, followed by 3.3 days at home. Infusion bags were exchanged every 2.5 days. No haemorrhagic complications occurred, and five haemorrhages that had been resistant to treatment with bolus injections responded promptly to the continuous infusion. There were no technical problems and patient compliance and acceptance was good. We find this mode of therapy safe, efficacious and convenient for the patients as well as for the staff.

  2. Synthesization of the Ar VIII 3s-3p beam-foil decay curve

    International Nuclear Information System (INIS)

    Lindgaard, A.; Veje, E.

    1981-01-01

    The beam-foil decay curve for the 3s-3p transition in Ar VIII has been simulated from experimentally determined relative initial level populations and transition probabilities calculated in the numerical Coulomb approximation. Good agreement is observed between simulated and measured decay curves. A discussion of the simulation is given. (Auth.)

  3. Quark matter coupled to domain walls in Bianchi types II, VIII and IX ...

    Indian Academy of Sciences (India)

    In this study of Bianchi types II, VIII and IX Universes, quark matter coupled to domain walls in the context of general relativity are explored. To obtain deterministic solution of the Einstein's field equations, various techniques are adopted. The features of the obtained solution are discussed.

  4. Chaos in long-term behavior of some Bianchi-type VIII models

    Energy Technology Data Exchange (ETDEWEB)

    Halpern, P

    1987-01-01

    The long-term behavior of Bianchi-type VIII models with three different types of stress-energy tensors are examined and compared. The vacuum model, a matter-filled model, and a model with an electromagnetic field are considered. In each case the existence of chaotic behavior and transitions to chaotic behavior are discussed.

  5. Absorption signatures of warm-hot gas at low redshift : Ne VIII

    NARCIS (Netherlands)

    Tepper-García, T

    2013-01-01

    At z {lt} 1 a large fraction of the baryons is thought to reside in diffuse gas that has been shock-heated to high temperatures (10$^{5}$-10$^{6}$ K). Absorption by the 770.41, 780.32 å doublet of Ne VIII in quasar spectra represents a unique tool to study this elusive warm-hot phase. We have

  6. In vivo recovery and safety of human factor VIII product AAFACT in patients with haemophilia A

    NARCIS (Netherlands)

    Vossebeld, P. J. M.; Tissing, M. H.; van den Berg, H. M.; Leebeek, F. W. G.; de Goede-Bolder, A.; Novakova, I. R. O.; Gerrits, W. B. J.; Peters, M.; Koopman, M. M. W.; Faber, A.; Hiemstra, H.; Grob, P.; Strengers, P. F. W.

    2003-01-01

    AAFACT, a monoclonal purified, solvent/detergent treated human plasma-derived coagulation factor VIII concentrate obtained from plasma of voluntary, non-remunerated blood donors, is manufactured and marketed in the Netherlands by Sanquin Plasma Products since 1995. In a postmarketing surveillance

  7. Safety and Efficacy of BAY 94-9027, a Prolonged-Half-Life Factor VIII

    DEFF Research Database (Denmark)

    Reding, M T; Ng, H J; Poulsen, Lone Hvitfeldt

    2017-01-01

    BACKGROUND: BAY 94-9027 is a B-domain-deleted prolonged-half-life recombinant factor VIII (FVIII) conjugates in a site-specific manner with polyethylene glycol. OBJECTIVE: Assess efficacy and safety of BAY 94-9027 for prophylaxis and treatment of bleeds in patients with severe hemophilia A PATIEN...

  8. Lithium ionophore VIII as an extraordinarily effective receptor for the strontium cation: Experimental and theoretical study

    Czech Academy of Sciences Publication Activity Database

    Makrlík, E.; Novák, Vít; Vaňura, P.; Bouř, Petr

    2014-01-01

    Roč. 1061, Mar 5 (2014), s. 110-113 ISSN 0022-2860 Institutional support: RVO:61388963 Keywords : strontium cation * lithium ionophore VIII * complexation * extraction and stability constants * DFT calculations * structures Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.602, year: 2014

  9. Complexation of the cesium cation with lithium ionophore VIII: extraction and DFT study

    Czech Academy of Sciences Publication Activity Database

    Makrlík, E.; Novák, Vít; Vaňura, P.; Bouř, Petr

    2013-01-01

    Roč. 298, č. 3 (2013), s. 2065-2068 ISSN 0236-5731 Institutional support: RVO:61388963 Keywords : cesium cation * lithium ionophore VIII * complexation * extraction and stability constants * water-nitrobenzene system * DFT calculations * structures Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 1.415, year: 2013

  10. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  11. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  12. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  13. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  14. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  15. RELATIONSHIP OF INTEREST, LEARNING MOTIVATION AND ATTITUDE WITH RESULTS LEARNING CLASS VIII SMP STATE 13 MAKASSAR

    Directory of Open Access Journals (Sweden)

    Putri Athirah Azis

    2016-12-01

    Full Text Available The study aims at examining (1 the correlation of learning interest towards learning result of grade students, (2 the correlation of learning motivation towards learning result of grade students, (3 the correlation of students attitude towards learning result, (4 the correlationof interest, learning motivation, and attitude collaboratively towards learning result. The study is an ex post facto. The population of the study was grade VIII at SMPN 13 Makassar. Samples were 105 students taken by employing random sampling technique. Data were collected through questionnaire and documentation. Data were analyzed using regression test. The result of study reveal that (1 there is significant correlation (p<0,01 of interest towards learning result of grade VIII students at SMPN 13 Makassar. Co-efficient correlation (r is 0,718 and its effectiveness contribution (R2 is 51,5%, (2 there is significant correlation (p<0,01 of motivation towards learning result of grade VIII students at SMPN 13 Makassar. Co-efficient correlation (r is 0,775 and its effectiveness contribution (R2 is 60,1%, (3 there is significant correlation (p<0,01 of attitude towards learning result of grade VIII students at SMPN 13 Makassar. Co-efficient correlation (r is 0,737 and its effectiveness contribution (R2 is 54,4%, (4 there is significant correlation (p<0,01 of interest, motivation and attitude collaboratively towards learning result of grade VIII students at SMPN 13 Makassar. Co-efficient correlation (r is 0,861 and its effectiveness contribution (R2 is 74,1%,

  16. VIII Olimpíada Brasileira de Astronomia e Astronáutica

    Science.gov (United States)

    Garcia Canalle, João Batista; Villas da Rocha, Jaime Fernando; Wuensche de Souza, Carlos Alexandre; Pereira Ortiz, Roberto; Aguilera, Nuricel Villalonga; Padilha, Maria De Fátima Catta Preta; Pessoa Filho, José Bezerra; Soares Rodrigues, Ivette Maria

    2007-07-01

    Neste trabalho apresentamos as motivações pelas quais organizamos, em conjunto, pela primeira vez, a Olimpíada Brasileira de Astronomia incluindo a Astronáutica, em colaboração com a Agência Espacial Brasileira. Esta ampliação contribuiu para atrair ainda mais alunos, professores, escolas e patrocinadores para participarem desta Olimpíada. Em 2005 participaram da VIII Olimpíada Brasileira de Astronomia e Astronáutica (VIII OBA) 187.726 alunos distribuídos por 3.229 escolas, pertencentes a todos os estados brasileiros, incluindo o Distrito Federal. O crescimento em número de alunos participantes foi 52,4% maior do que em 2004. Em abril de 2005 organizamos, em Itapecerica da Serra, SP, um curso para os 50 alunos previamente selecionados e participantes da VII OBA e ao final selecionamos, dentre eles, uma equipe de 5 alunos, os quais representaram o Brasil na X Olimpíada Internacional de Astronomia, na China, em outubro de 2005. Ganhamos, pela primeira vez, uma medalha de ouro naquele evento. Em Agosto de 2005, organizamos a VIII Escola de Agosto para 50 alunos e respectivos professores, em Águas de Lindóia, SP, juntamente com a XXXI reunião anual da Sociedade Astronômica Brasileira (SAB). Em novembro de 2005 realizamos a I Jornada Espacial, em São José dos Campos, com 22 alunos e 22 professores selecionados dentre os participantes que melhores resultados obtiveram nas questões de Astronáutica da VIII OBA. Neste trabalho detalhamos os resultados da VIII OBA bem como as ações subseqüentes.

  17. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  18. VIII. Safety and method of work in ionizing radiation applications

    International Nuclear Information System (INIS)

    1984-01-01

    Ionizing radiation may damage the organism in two ways: the damage may be chronic or acute. The characteristics of the two types of damage are described. The Czechoslovak State Standard allows the level of 50 mSv as the maximum permissible dose for whole-body exposure for personnel working with radiation. In case of sources incorporated in the body of the workers the maximum permissible dose should not exceed the value of 2.8 μSv/h during decay. Precautions are given for operation with X-ray instruments. In the X-ray room good ventilation must be provided in view of the presence of ozone and oxides. Diagnostic and therapeutical instruments are placed in a separate room from control instruments. The walls are reinforced with barite concrete. Tables are given showing excitation voltage in kV of primary radiation at which the shortest wavelengths and corresponding voltage would be o.enerated scattered at different angles and with minimum wavelength. Also given are thicknesses of the lead layer in mm for different distances from the source and for different voltages in kV at 10 mA. Corrections are given for other current intensities. Radiation protection of personnel working with sealed sources may be achieved by shielding, shortening the time required for handling and the distance at which the source is operated. For operating unsealed radioactive sources various types of shieldings are used depending on the type of radiation. Workplaces are classified into three categories and hygiene regulations are summed up for work with unsealed sources. (E.S.)

  19. Innovations in Balloon Catheter Technology in Rhinology.

    Science.gov (United States)

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  1. Specific membrane binding of factor VIII is mediated by O-phospho-L-serine, a moiety of phosphatidylserine.

    Science.gov (United States)

    Gilbert, G E; Drinkwater, D

    1993-09-21

    Phosphatidylserine, a negatively charged lipid, is exposed on the platelet membrane following cell stimulation, correlating with the expression of factor VIII receptors. We have explored the importance of the negative electrostatic potential of phosphatidylserine vs chemical moieties of phosphatidylserine for specific membrane binding of factor VIII. Fluorescein-labeled factor VIII bound to membranes containing 15% phosphatidic acid, a negatively charged phospholipid, with low affinity compared to phosphatidylserine-containing membranes. Binding was not specific as it was inhibited by other proteins in plasma. Factor VIII bound to membranes containing 10% phosphatidylserine in spite of a varying net charge provided by 0-15% stearylamine, a positively charged lipid. The soluble phosphatidylserine moiety, O-phospho-L-serine, inhibited factor VIII binding to phosphatidylserine-containing membranes with a Ki of 20 mM, but the stereoisomer, O-phospho-D-serine, was 5-fold less effective. Furthermore, binding of factor VIII to membranes containing synthetic phosphatidyl-D-serine was 5-fold less than binding to membranes containing phosphatidyl-L-serine. Membranes containing synthetic phosphatidyl-L-homoserine, differing from phosphatidylserine by a single methylene, supported high-affinity binding, but it was not specific as factor VIII was displaced by other plasma proteins. O-Phospho-L-serine also inhibited the binding of factor VIII to platelet-derived microparticles with a Ki of 20 mM, and the stereoisomer was 4-fold less effective. These results indicate that membrane binding of factor VIII is mediated by a stereoselective recognition O-phospho-L-serine of phosphatidylserine and that negative electrostatic potential is of lesser importance.

  2. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  3. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  4. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  5. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  6. Population pharmacokinetics of recombinant coagulation factor VIII-SingleChain in patients with severe hemophilia A.

    Science.gov (United States)

    Zhang, Y; Roberts, J; Tortorici, M; Veldman, A; St Ledger, K; Feussner, A; Sidhu, J

    2017-06-01

    Essentials rVIII-SingleChain is a unique recombinant factor VIII (FVIII) molecule. A population pharmacokinetic model was based on FVIII activity of severe hemophilia A patients. The model was used to simulate factor VIII activity-time profiles for various dosing scenarios. The model supports prolonged dosing of rVIII-SingleChain with intervals of up to twice per week. Background Single-chain recombinant coagulation factor VIII (rVIII-SingleChain) is a unique recombinant coagulation factor VIII molecule. Objectives To: (i) characterize the population pharmacokinetics (PK) of rVIII-SingleChain in patients with severe hemophilia A; (ii) identify correlates of variability in rVIII-SingleChain PK; and (iii) simulate various dosing scenarios of rVIII-SingleChain. Patients/Methods A population PK model was developed, based on FVIII activity levels of 130 patients with severe hemophilia A (n = 91 for ≥ 12-65 years; n = 39 for  85% and > 93% of patients were predicted to maintain FVIII activity level above 1 IU dL -1 , at all times with three-times-weekly dosing (given on days 0, 2, and 4.5) at the lowest (20 IU kg -1 ) and highest (50 IU kg -1 ) doses, respectively. For twice weekly dosing (days 0 and 3.5) of 50 IU kg -1 rVIII-SingleChain, 62-80% of patients across all ages were predicted to maintain a FVIII activity level above 1 IU dL -1 at day 7. Conclusions The population PK model adequately characterized rVIII-SingleChain PK, and the model can be utilized to simulate FVIII activity-time profiles for various dosing scenarios. © 2017 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.

  7. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  8. Hickman catheter embolism in a child during stem cell transplantation

    International Nuclear Information System (INIS)

    Ahmed, P.; Khan, B.; Ullah, K.; Ahmed, W.; Hussain, I.; Khan, A.A.; Anwar, M.

    2003-01-01

    The majority of stem cell recipients rely on indwelling central venous catheters situated in superior vena cava or right atrium. Semi-permanent tunneled silicone rubber Hickman catheters are widely used to provide durable central venous access for patients undergoing stem cell transplantation. A case of 5 years old child with diagnosis of severe aplastic anemia is reported. The patient received peripheral blood stem cells (PBSC) and had successful engraftment with complete hematological recovery. He had Hickman catheter embolism in the pulmonary circulation following unsuccessful attempt to remove the line. The catherter was successfully removed by midsternostomy operation. The child is normal with sustained remission on day +218 post stem cell transplant. (author)

  9. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  10. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  11. Percutaneous untying of a knot in a retained Swan-Ganz catheter

    International Nuclear Information System (INIS)

    Bhatti, Waqar A.; Sinha, Sankar; Rowlands, Peter

    2000-01-01

    A patient was referred to us with a tightly knotted Swan-Ganz catheter. The catheter could not be removed by conventional simple methods. We describe a minimally invasive means of removal of the catheter using an Amplatz gooseneck snare and an angioplasty balloon. This allowed the Catheter to be removed without trauma.

  12. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  13. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  14. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  15. Instrumental aspects

    Directory of Open Access Journals (Sweden)

    Qureshi Navid

    2017-01-01

    Full Text Available Every neutron scattering experiment requires the choice of a suited neutron diffractometer (or spectrometer in the case of inelastic scattering with its optimal configuration in order to accomplish the experimental tasks in the most successful way. Most generally, the compromise between the incident neutron flux and the instrumental resolution has to be considered, which is depending on a number of optical devices which are positioned in the neutron beam path. In this chapter the basic instrumental principles of neutron diffraction will be explained. Examples of different types of experiments and their respective expectable results will be shown. Furthermore, the production and use of polarized neutrons will be stressed.

  16. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  17. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  18. Surgical Instrument

    NARCIS (Netherlands)

    Dankelman, J.; Horeman, T.

    2009-01-01

    The present invention relates to a surgical instrument for minimall-invasive surgery, comprising a handle, a shaft and an actuating part, characterised by a gastight cover surrounding the shaft, wherein the cover is provided with a coupler that has a feed- through opening with a loskable seal,

  19. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  20. Catheter Calibration Using Template Matching Line Interpolation Algorithm

    National Research Council Canada - National Science Library

    Nagy, L

    2001-01-01

    ..., such as: image resolution, type of the calibration, algorithm used for contour detection, size of the FOV, other parameters of the image The studied calibration method is the one using catheter size...

  1. Experience with the Bonanno Catheter in the Management of OHSS ...

    African Journals Online (AJOL)

    : A retrospective study of all IVF ... Result: Within the period under review, 234 patients had controlled ... (six intrauterine, one ectopic and one heterotopic pregnancies), giving a clinical ... The Bonanno catheter is a medical device described by.

  2. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  3. Catheter ablation in the treatment of electrical storm: Integrative review

    Directory of Open Access Journals (Sweden)

    Ricardo Teixeira Leal

    2017-09-01

    Conclusion: Catheter ablation is the initial therapy for patients with ischemic cardiomyopathy (ICM and ES. The endocardial approach presents more relevant success rates than the other therapeutic methods presented.

  4. Catheter-Related Sepsis Due to Rhodotorula glutinis

    Science.gov (United States)

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  5. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  6. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  7. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  8. Urinary catheter with polyurethane coating modified by ion implantation

    International Nuclear Information System (INIS)

    Kondyurina, I.; Nechitailo, G.S.; Svistkov, A.L.; Kondyurin, A.; Bilek, M.

    2015-01-01

    A low friction urinary catheter that could be used without a lubricant is proposed in this work. A polyurethane coating was synthesised on the surface of a metal guide wire catheter. Ion implantation was applied to surface modify the polyurethane coating. FTIR ATR, wetting angle, AFM and friction tests were used for analysis. Low friction was found to be provided by the formation of a hard carbonised layer on the polyurethane surface

  9. False coronary dissection with the new Monorail angioplasty balloon catheter.

    Science.gov (United States)

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  10. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    OpenAIRE

    Zhou J; Zamdborg L; Sebastian E

    2015-01-01

    Jun Zhou,1,2 Leonid Zamdborg,1 Evelyn Sebastian1 1Department of Radiation Oncology, Beaumont Health System, 2Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA Abstract: The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy ...

  11. Massive hydrothorax with malpositioned central venous catheter – Ultrasound detection

    Directory of Open Access Journals (Sweden)

    Neha Hasija

    2016-04-01

    Full Text Available Radioimaging is the gold standard for confirmation of the position of central venous catheter as well as its related complications. Use of ultrasound has been proven in guiding central venous cannulations, and it can also be used in detecting related complications. We report a case of a 2 year old child with hydrothorax causing desaturation due to malpositioned central venous catheter diagnosed by ultrasound in the delay for getting a radiograph.

  12. Compact invariant sets of the Bianchi VIII and Bianchi IX Hamiltonian systems

    International Nuclear Information System (INIS)

    Starkov, Konstantin E.

    2011-01-01

    In this Letter we prove that all compact invariant sets of the Bianchi VIII Hamiltonian system are contained in the set described by several simple linear equalities and inequalities. Moreover, we describe invariant domains in which the phase flow of this system has no recurrence property and show that there are no periodic orbits and neither homoclinic, nor heteroclinic orbits contained in the zero level set of its Hamiltonian. Similar results are obtained for the Bianchi IX Hamiltonian system. -- Highlights: → Zero level set of Hamiltonian of Bianchi VIII/IX systems contains no periodic orbits. → Similar conditions for homoclinic/heteroclinic orbits are given. → General nonexistence conditions of compact invariant sets are got.

  13. Compact invariant sets of the Bianchi VIII and Bianchi IX Hamiltonian systems

    Energy Technology Data Exchange (ETDEWEB)

    Starkov, Konstantin E., E-mail: konst@citedi.mx [CITEDI-IPN, Av. del Parque 1310, Mesa de Otay, Tijuana, BC (Mexico)

    2011-08-22

    In this Letter we prove that all compact invariant sets of the Bianchi VIII Hamiltonian system are contained in the set described by several simple linear equalities and inequalities. Moreover, we describe invariant domains in which the phase flow of this system has no recurrence property and show that there are no periodic orbits and neither homoclinic, nor heteroclinic orbits contained in the zero level set of its Hamiltonian. Similar results are obtained for the Bianchi IX Hamiltonian system. -- Highlights: → Zero level set of Hamiltonian of Bianchi VIII/IX systems contains no periodic orbits. → Similar conditions for homoclinic/heteroclinic orbits are given. → General nonexistence conditions of compact invariant sets are got.

  14. Haemophilia A: Database of nucleotide substitutions, deletions, insertions and rearrangements of the factor VIII gene

    Energy Technology Data Exchange (ETDEWEB)

    Tuddenham, E.G.D. (Clinical Research Centre, Harrow (United Kingdom)); Cooper, D.N. (Thrombosis Research Inst., London (United Kingdom)); Gitschier, J. (Univ. of California, San Francisco (United States)); Higuchi, M.; Kazazian, H.H.; Antonarakis, S.E. (Johns Hopkins Univ., Baltimore (United States)); Hoyer, L.W. (American Red Cross, Rockville (United States)); Yoshioka, A. (Nara Medical Coll., Kashihara City (Japan)); Peake, I.R. (Royal Hallamshire Hospital, Sheffield (United Kingdom)); Schwaab, R. (Inst. fuer Klinische Biochemie der Univ. Bonn (West Germany)); Lavergne, J.M. (Hopital de Bicetre (France)); Giannelli, F. (Guy' s Hospital, London (United Kingdom))

    1991-09-25

    Mutations at the factor VIII gene locus causing Haemophilia A have now been identified in many patients from a many ethnic groups. Earlier studies used biased methods which detected repetitive mutations at a few CG dinucleotides. More recently rapid gene scanning methods have uncovered an extreme diversity of mutations. Over 80 different point mutations, 6 insertions, 7 small deletions, and 60 large deletions have been characterized. Repetitive mutation has been proved for at least 16 CpG sites. All nonsense mutations cause severe disease. Most missense mutations appear to cause instability of the protein, but some are associated with production of dysfunctional factor VIII molecules, thereby localizing functionally critical regions of the cofactor. Variable phenotype has been observed in association with three of the latter class of genotype. This catalogue of gene lesions in Haemophilia A will be updated annually.

  15. Detection of Intracellular Factor VIII Protein in Peripheral Blood Mononuclear Cells by Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Gouri Shankar Pandey

    2013-01-01

    Full Text Available Flow cytometry is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. Detection of specific host proteins for diagnosis predominantly uses quantitative PCR and western blotting assays. In this study, we optimized a flow cytometry-based detection assay for Factor VIII protein in peripheral blood mononuclear cells (PBMCs. An indirect intracellular staining (ICS method was standardized using monoclonal antibodies to different domains of human Factor VIII protein. The FVIII protein expression level was estimated by calculating the mean and median fluorescence intensities (MFI values for each monoclonal antibody. ICS staining of transiently transfected cell lines supported the method's specificity. Intracellular FVIII protein expression was also detected by the monoclonal antibodies used in the study in PBMCs of five blood donors. In summary, our data suggest that intracellular FVIII detection in PBMCs of hemophilia A patients can be a rapid and reliable method to detect intracellular FVIII levels.

  16. PENGARUH KEMANDIRIAN BELAJAR DAN PENGGUNAAN UANG SAKU TERHADAP PRESTASI BELAJAR KOMPETENSI DASAR EKONOMI KELAS VII DAN VIII

    OpenAIRE

    Apri Dwi Astuti

    2012-01-01

    Kemandirian belajar membantu siswa untuk bertanggung jawab dan menumbuhkan kesadaran belajar. Penggunaan uang saku menumbuhkan jiwa mandiri, jujur dan komitmen. Adapun hasil observasi awal menunjukkan masih ada siswa kels VII dan VIII SMP Semesta untuk kompetensi dasar ekonomi dibawah KKM. Tujuan penelitian ini untuk mengetahui pengaruh kemandirian belajar dn penggunaan uang saku terhadap prestasi belajar kompetensi dasar ekonomi kelas VII dan VIII SMP Semesta. Populasi penelitian ini adalah ...

  17. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  18. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  19. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  20. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  1. Construction of a mouse model of factor VIII deficiency by gene targeting

    Energy Technology Data Exchange (ETDEWEB)

    Bi, L.; Lawler, A.; Gearhart, J. [Univ. of Pennsylvania School of Medicine, Philadelphia, PA (United States)] [and others

    1994-09-01

    To develop a small animal model of hemophilia A for gene therapy experiments, we set out to construct a mouse model for factor VIII deficiency by gene targeting. First, we screened a mouse liver cDNA library using a human FVIII cDNA probe. We cloned a 2.6 Kb partial mouse factor VIII cDNA which extends from 800 base pairs of the 3{prime} end of exon 14 to the 5{prime} end of exon 26. A mouse genomic library made from strain 129 was then screened to obtain genomic fragments covering the exons desired for homologous recombination. Two genomic clones were obtained, and one covering exon 15 through 22 was used for gene targeting. To make gene targeting constructs, a 5.8 Kb genomic DNA fragment covering exons 15 to 19 of the mouse FVIII gene was subcloned, and the neo expression cassette was inserted into exons 16 and 17 separately by different strategies. These two constructs were named MFVIIIC-16 and MFVIIIC-17. The constructs were linearized and transfected into strain 129 mouse ES cells by electroporation. Factor VIII gene-knockout ES cell lines were selected by G-418 and screened by genomic Southern blots. Eight exon 16 targeted cell lines and five exon 17 targeted cell lines were obtained. Three cell lines from each construct were injected into blastocysts and surgically transferred into foster mothers. Multiple chimeric mice with 70-90% hair color derived from the ES-cell genotype were seen with both constructs. Germ line transmission of the ES-cell genotype has been obtained for the MFVIIIC-16 construct, and multiple hemophilia A carrier females have been identified. Factor VIII-deficient males will be conceived soon.

  2. Structural Mimics of the [Fe]-Hydrogenase: A Complete Set for Group VIII Metals.

    Science.gov (United States)

    Barik, Chandan Kr; Ganguly, Rakesh; Li, Yongxin; Leong, Weng Kee

    2018-06-18

    A set of structural mimics of the [Fe]-hydrogenase active site comprising all the group VIII metals, viz., [M(2-NHC(O)C 5 H 4 N)(CO) 2 (2-S-C 5 H 4 N)], has been synthesized. They exist as a mixture of isomers in solution, and the relative stability of the isomers depends on the nature of the metal and the substituent at the 6-position of the pyridine ligand.

  3. Historical intensity VIII earthquakes along the Rhone valley (Valais, Switzerland): primary and secondary effects

    Energy Technology Data Exchange (ETDEWEB)

    Fritsche, S.; Faeh, D.; Schwarz-Zanetti, G.

    2012-06-15

    In recent years the upper Rhone Valley has been one of the most intensively investigated regions by the Swiss Seismological Service. The high seismicity in the region encourages research in the seismological field and one main focus has been historical seismology. This report presents the state of the art of our historical investigations by giving an overview of the effects of four damaging earthquakes with intensity larger than VII, for which a fairly large number of documents could be found and analyzed. The overview includes the events of 1584 (Aigle, epicentral intensity VIII), 1755 (Brig, epicentral intensity VIII), 1855 (Visp, epicentral intensity VIII), and 1946 (Sierre, epicentral intensity VIII for the main shock and intensity VII for the largest aftershock). The paper focuses mainly on primary and secondary effects in the epicentral region, providing the key data and a general characterization of the event. Generally, primary effects such as the reaction of the population and impact on buildings took more focus in the past. Thus building damage is more frequently described in historic documents. However, we also found a number of sources describing secondary effects such as landslides, snow avalanches, and liquefaction. Since the sources may be useful, we include citations of these documents. The 1584 Aigle event, for example, produced exceptional movements in the Lake of Geneva, which can be explained by an expanded sub aquatic slide with resultant tsunami and seiche. The strongest of the aftershocks of the 1584 event triggered a destructive landslide covering the villages Corbeyrier and Yvorne, Vaud. All macroseismic data on the discussed events are accessible through the web page of the Swiss Seismological Service (http://www.seismo.ethz.ch). (authors)

  4. VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis. Program. Summary of reports

    International Nuclear Information System (INIS)

    2001-01-01

    Program and summary of reports of the VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis are performed. The meeting took place 15-19 October, 2001 in Moscow. Many problems of liquid and ion exchange chromatography, capillary electrophoresis, thin-layer chromatography have been discussed extensively. Reports covering properties of sorbents and devices for chromatography are incorporated in the collection [ru

  5. Circumventing furin enhances factor VIII biological activity and ameliorates bleeding phenotypes in hemophilia models

    OpenAIRE

    Siner, Joshua I.; Samelson-Jones, Benjamin J.; Crudele, Julie M.; French, Robert A.; Lee, Benjamin J.; Zhou, Shanzhen; Merricks, Elizabeth; Raymer, Robin; Nichols, Timothy C.; Camire, Rodney M.; Arruda, Valder R.

    2016-01-01

    Processing by the proprotein convertase furin is believed to be critical for the biological activity of multiple proteins involved in hemostasis, including coagulation factor VIII (FVIII). This belief prompted the retention of the furin recognition motif (amino acids 1645–1648) in the design of B-domain–deleted FVIII (FVIII-BDD) products in current clinical use and in the drug development pipeline, as well as in experimental FVIII gene therapy strategies. Here, we report that processing by fu...

  6. Structural characterization of the novel aminoglycoside phosphotransferase AphVIII from Streptomyces rimosus with enzymatic activity modulated by phosphorylation

    Energy Technology Data Exchange (ETDEWEB)

    Boyko, Konstantin M., E-mail: kmb@inbi.ras.ru [Bach Institute of Biochemistry, Federal Research Centre of Biotechnology of the Russian Academy of Sciences, Leninsky Prospekt. 33, Bld. 2, 119071, Moscow (Russian Federation); National Research Center “Kurchatov Institute”, Kurchatov Complex of NBICS-technologies, Akad. Kurchatova sqr., 1, Moscow, 123182 (Russian Federation); Gorbacheva, Marina A.; Korzhenevskiy, Dmitry A. [National Research Center “Kurchatov Institute”, Kurchatov Complex of NBICS-technologies, Akad. Kurchatova sqr., 1, Moscow, 123182 (Russian Federation); Alekseeva, Maria G.; Mavletova, Dilara A.; Zakharevich, Natalia V.; Elizarov, Sergey M.; Rudakova, Natalia N.; Danilenko, Valery N. [Vavilov Institute of General Genetics, Russian Academy of Sciences, Gubkina str. 3, Moscow, 119333 (Russian Federation); Popov, Vladimir O. [Bach Institute of Biochemistry, Federal Research Centre of Biotechnology of the Russian Academy of Sciences, Leninsky Prospekt. 33, Bld. 2, 119071, Moscow (Russian Federation); National Research Center “Kurchatov Institute”, Kurchatov Complex of NBICS-technologies, Akad. Kurchatova sqr., 1, Moscow, 123182 (Russian Federation)

    2016-09-02

    Aminoglycoside phosphotransferases represent a broad class of enzymes that promote bacterial resistance to aminoglycoside antibiotics via the phosphorylation of hydroxyl groups in the latter. Here we report the spatial structure of the 3′-aminoglycoside phosphotransferase of novel VIII class (AphVIII) solved by X-ray diffraction method with a resolution of 2.15 Å. Deep analysis of APHVIII structure and its comparison with known structures of aminoglycoside phosphotransferases of various types reveals that AphVIII has a typical two-domain fold and, however, possesses some unique characteristics that distinguish the enzyme from its known homologues. The most important difference is the presence of the activation loop with unique Ser146 residue. We demonstrate that in the apo-state of the enzyme the activation loop does not interact with other parts of the enzyme and seems to adopt catalytically competent state only after substrate binding. - Highlights: • 3D structure of the novel aminoglycoside phosphotransferase AphVIII was obtained. • AphVIII activation loop is clearly identified in the electron density. • AphVIII has some unique structural features in its substrate C-ring binding pocket.

  7. PERSEPSI SISWA KELAS VIII TENTANG KESEHATAN REPRODUKSI REMAJA DAN PENYAKIT MENULAR SEKSUAL

    Directory of Open Access Journals (Sweden)

    Omega Rianda Rustian

    2015-06-01

    This study is based on interviews conducted in one of the BK school teacher. This study aimed to determine the perception class VIII student perceptions on adolescent reproductive health and sexually transmitted diseases in SMP Islam Sultan Agung 1 Semarang. The method used in this research is descriptive quantitative survey methods. Population in this research is class VIII SMP Islam Sultan Agung 1 Semarang totaling 151 students with a sampling technique used is accidental to obtain a sample of 60. Data collection tools in the form of a psychological scale with data analysis techniques using descriptive analysis percentage. The average result of students' perceptions on adolescent reproductive health in the high category (74% and perceptions of students about sexually transmitted diseases in the very high category (76%. That class VIII SMP Islam Sultan Agung 1 Semarang already have an idea of the meaning of adolescent reproductive health is a state of good health both physically healthy, functioning, as well as reproductive performance in adolescent and the  meaning of sexually transmitted diseases are caused by viruses, parasites, or function as a result of sexual intercourse.

  8. A close insight to factor VIII inhibitor in the congenital hemophilia A.

    Science.gov (United States)

    Tabriznia-Tabrizi, Shamsoreza; Gholampour, Marzie; Mansouritorghabeh, Hassan

    2016-09-01

    Hemophilia A (HA) has an X-linked pattern of inheritance and is the most common of the hemorrhagic disorders. HA is caused by a decreased or deficiency of the functional clotting factor VIII (FVIII) and effects 1 in 5000-10,000 male births. The common treatment for hemophilia is replacement therapy by plasma-derived or recombinant FVIII. Approximately 20-30% of people with a severe type of HA develop an inhibitor and this phenomenon is the main challenge in the management of these patients. Genetic factors and environmental determinants contribute to inhibitor development. Here, the roles of various genetic and environmental factors such as the type of FVIII concentrate used, the number of exposure days, and peak treatment time will be discussed in detail. It seems this information is helpful for hematologists. A literature review was done in January 2016 on PubMed and Scopus using the following keywords:' h(a)emophilia A & factor VIII inhibitor', 'h(a)emophilia A & factor VIII alloantibody', 'h(a)emophilia A & inhibitor'. There was no time limitation; however, there was an English language limitation placed on the articles selected. Expert commentary: Influential genetic and environmental factors in developing inhibitors have been discussed. Most of the risk factors are related to previously untreated patients with hemophili.

  9. Mechanism of prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Maynar, M.; Hulbert, J.

    1988-01-01

    A series of 60 patients have undergone prostatic urethroplasty with balloon catheters at our institution. The follow-up of these patients has ranged from more than 3 years to not less than 6 months. The preliminary results have been excellent, with a success rate of 75% in patients with predominant lateral lobe hypertrophy. This success rate drops to 25% in patients with predominant middle lobe hypertrophy. In previous communications the authors have proposed that the mechanism of prostatic urethral relief of obstruction is due to stretching of the prostatic capsule, tissue compression, and possible subsequent atrophy, as suggested by findings of transrectal US, MR imaging, voiding and retrograde urethrography, and urinary flow studies. Recent clinical information that has led to further animal research has shown that in addition to the previously supposed mechanism of action, separation of the prostatic lobes occurs by splitting of the anterior and posterior commissures of the prostatic gland tissue. This separation of the prostatic lobes is therefore the goal of the procedure. As more experience is gained, the already high success rate can probably be improved

  10. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Bighi, G.

    1988-01-01

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  11. Pulsatile flow in ventricular catheters for hydrocephalus

    Science.gov (United States)

    Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.

    2017-05-01

    The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.

  12. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  13. Divided Instruments

    Science.gov (United States)

    Chapman, A.; Murdin, P.

    2000-11-01

    Although the division of the zodiac into 360° probably derives from Egypt or Assyria around 2000 BC, there is no surviving evidence of Mesopotamian cultures embodying this division into a mathematical instrument. Almost certainly, however, it was from Babylonia that the Greek geometers learned of the 360° circle, and by c. 80 BC they had incorporated it into that remarkably elaborate device gener...

  14. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  15. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  16. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  17. Intracardiac Echocardiography Guided Transeptal Catheter Injection of Microspheres for Assessment of Cerebral Microcirculation in Experimental Models

    Directory of Open Access Journals (Sweden)

    Judith Bellapart

    2013-01-01

    Full Text Available The use of microspheres for the determination of regional microvascular blood flow (RMBF has previously used different approaches. This study presents for the first time the intracardiac injection of microspheres using transeptal puncture under intracardiac echocardiography guidance. Five Merino sheep were instrumented and cardiovascularly supported according to local guidelines. Two catheter sheaths into the internal jugular vein facilitated the introduction of an intracardiac probe and transeptal catheter, respectively. Five million colour coded microspheres were injected into the left atrium via this catheter. After euthanasia the brain was used as proof of principle and the endpoint for determination of microcirculation at different time points. Homogeneous allocation of microspheres to different regions of the brain was found over time. Alternate slices from both hemispheres showed the following flow ranges: for slice 02; 0.57–1.02 mL/min/g, slice 04; 0.45–1.42 mL/min/g, slice 06; 0.35–1.87 mL/min/g, slice 08; 0.46–1.77 mL/min/g, slice 10; 0.34–1.28 mL/min/g. A mixed effect regression model demonstrated that the confidence interval did include zero suggesting that the apparent variability intra- and intersubject was not statistically significant, supporting the stability and reproducibility of the injection technique. This study demonstrates the feasibility of the transeptal injection of microspheres, showing a homogeneous distribution of blood flow through the brain unchanged over time and has established a new interventional model for the measurement of RMBF in ovine models.

  18. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  19. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  20. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  1. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    Science.gov (United States)

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  2. Development of the evaluation instrument use CIPP on the implementation of project assessment topic optik

    Science.gov (United States)

    Asfaroh, Jati Aurum; Rosana, Dadan; Supahar

    2017-08-01

    This research aims to develop an evaluation instrument models CIPP valid and reliable as well as determine the feasibility and practicality of an evaluation instrument models CIPP. An evaluation instrument models CIPP to evaluate the implementation of the project assessment topic optik to measure problem-solving skills of junior high school class VIII in the Yogyakarta region. This research is a model of development that uses 4-D. Subject of product trials are students in class VIII SMP N 1 Galur and SMP N 1 Sleman. Data collection techniques in this research using non-test techniques include interviews, questionnaires and observations. Validity in this research was analyzed using V'Aikens. Reliability analyzed using ICC. This research uses 7 raters are derived from two lecturers expert (expert judgment), two practitioners (science teacher) and three colleagues. The results of this research is the evaluation's instrument model of CIPP is used to evaluate the implementation of the implementation of the project assessment instruments. The validity result of evaluation instrument have V'Aikens values between 0.86 to 1, which means a valid and 0.836 reliability values into categories so well that it has been worth used as an evaluation instrument.

  3. Factor VIII levels and the risk of pre-eclampsia, HELLP syndrome, pregnancy related hypertension and severe intrauterine growth retardation.

    Science.gov (United States)

    Witsenburg, C P J; Rosendaal, F R; Middeldorp, J M; Van der Meer, F J M; Scherjon, S A

    2005-01-01

    Recently, acquired as well as genetic prothrombotic factors are associated with thrombotic events. These factors have also been related to conditions of uteroplacental insufficiency such as pre-eclampsia, HELLP syndrome and severe intrauterine growth restriction (IUGR). The aim of this study was to determine whether elevated factor VIII levels are associated with uteroplacental insufficiency, in particular pre-eclampsia, HELLP syndrome or pregnancy-induced hypertension and intrauterine growth retardation. Plasma samples of 75 women with a history of pregnancy complicated by pre-eclampsia, HELLP syndrome, pregnancy induced hypertension or intrauterine growth restriction were tested for factor VIII:C (FVIII:C) levels at a minimum of 10 weeks post-partum. Laboratory results were compared to factor VIII:C levels found in a healthy control group of 272 women. Mean factor VIII:C levels were similar at 123 IU/dl in both the patient group and the controls. In a logistic regression model, after adjusting for age and blood group, no effect of factor VIII:C levels on the risk of pregnancy complications was observed, with the exception of IUGR with (OR 2.9, CI 1.0-8.7) or without hypertension (OR 2.0, CI 0.7-6.4). If the elevated level of factor VIII would be the sole factor responsible for the increased risk observed, one would expect to find an effect of blood group on risk as well (blood group being an important determinant of FVIII:C). While no such effect could be shown a causal relationship between elevated levels of factor VIII and conditions of uteroplacental insufficiency such as pre-eclampsia, HELLP syndrome, pregnancy-induced hypertension and IUGR is not very likely.

  4. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  5. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  6. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  7. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  8. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  9. Peripheral intravenous catheter-related phlebitis and related risk factors.

    Science.gov (United States)

    Nassaji-Zavareh, M; Ghorbani, R

    2007-08-01

    Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.

  10. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  11. Performance analysis of the T-DOC® air-charged catheters: An alternate technology for urodynamics.

    Science.gov (United States)

    Couri, Bruna M; Bitzos, Stephanie; Bhardwaj, Deepak; Lockhart, Emily; Yue, Andy; Goping, Ing

    2018-02-01

    Urodynamics (UDS) is widely used for the diagnosis of lower urinary tract dysfunction. Air-Charged catheters (ACC), one of the newer technologies for UDS pressure recording, has been adopted in growing numbers around the world for the past 15 years. Currently, there is a lack of published studies characterizing specific performance of the ACC. Since linearity, hysteresis, pressure drift, and frequency response are important components in characterizing accuracy for catheter-manometer systems; this study aimed to assess these four aspects in ACC. A total of 180 T-DOC® ACC were used in three different laboratory settings to assess pressure linearity and hysteresis (15 dual-sensor vesical and urethral and 30 single-sensor abdominal), pressure drift over 2 h (115 single-sensor), and frequency response (20 single-sensor). Data are presented as mean ± standard deviation. ACC showed linearity of 0.99 ± 0.01, 0.99 ± 0.01, and 1.01 ± 0.01; and hysteresis of 0.57 ± 0.3%, 0.76 ± 0.48%, and 1 ± 0.89% for the abdominal, vesical, and urethral sensors, respectively. A pressure drift of 2.2 ± 1.4% at 1 h and 4.4 ± 2.5% at 2 h were observed when compared to baseline pressures. The catheters did not show any amplification factor during the sweep from 1 to 30 Hz, and recorded signals up to 5 Hz attenuating higher frequency signals. In this study the T-DOC® ACC showed a linear performance with minimal hysteresis associated with acceptable pressure drift, and adequate frequency response to capture clinically relevant pressures. The accurate results observed in this study suggest that these catheters are technically suitable to be used as a measuring instrument for UDS. © 2017 Wiley Periodicals, Inc.

  12. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  13. Measurement of peripheral venous catheter-related phlebitis: a cross-sectional study.

    Science.gov (United States)

    Göransson, Katarina; Förberg, Ulrika; Johansson, Eva; Unbeck, Maria

    2017-09-01

    Many instruments for measurement of peripheral venous catheter (PVC)-related phlebitis are available, but no consensus exists on their applicability in clinical practice. This absence of consensus affects the ability to identify and compare proportions of PVCs causing phlebitis within and across hospitals as the range varies between 2% and 62% in previous studies. We hypothesised that the instruments' ability to identify phlebitis varies. The aim of this study is to illustrate the complexity of application of phlebitis instruments to a clinical dataset. In this cross-sectional study, we applied 17 instruments for phlebitis identification (divided into three groups [instruments using definitions, severity rating systems, and scoring systems]) to PVCs in adult patients admitted to 12 inpatient units at Karolinska University Hospital in Sweden. We calculated the proportion of PVCs causing phlebitis on the basis of each instrument's minimum criterion for phlebitis. We also analysed each instrument's face validity. We compared proportions using the Z test. On the basis of data collected between Feb 2, 2009, and Feb 20, 2009, May 18, 2009, and June 5, 2009, and Feb 8, 2010, and Feb 26, 2010, we applied 17 instruments for phlebitis identification (eight instruments using definitions, seven severity rating systems, and two scoring systems) to 1175 observed PVCs in 1032 patients. The highest number of PVCs causing phlebitis generated by definitions was 137 (11·7%), by severity rating systems was 395 (33·6%), and by scoring systems was 363 (30·9%). The proportion generated by instruments using definitions was significantly different to that of both the severity rating (difference 21·9% [95% CI 18·6-25·2]; pphlebitis published in the scientific community. From a work environment and patient safety perspective, clinical staff engaged in PVC management should be aware of the absence of adequately validated instruments for phlebitis assessment. We suggest that researchers

  14. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  15. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  16. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  17. Penile gangrene following condom catheter urinary drainage : A case report

    Directory of Open Access Journals (Sweden)

    Sandhya Gupta

    2016-04-01

    Full Text Available External urine collecting devices have been a boon to patients of urinary incontinence since their invention in late 90s. They have replaced the need for uncomfortable indwelling catheters in these patients. As safe as they may be, ghastly complications have occurred infrequently, mostly due to their inappropriate application. Such penile and urethral complications add to the morbidity of the patients significantly. They can be easily avoided by following few simple steps of catheter care, thus emphasizing the need to aware clinicians and health care workers about the correct application methods. Here we discuss a case of 60 year old male who developed penile skin necrosis and urethral fistula due to chronic use of condom catheter.

  18. Suicide by severing the arterio-venous subclavian dialysis catheter.

    Science.gov (United States)

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  19. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  20. Crystal Structure of Human Factor VIII: Implications for the Formation of the Factor IXa-Factor VIIIa Complex

    Energy Technology Data Exchange (ETDEWEB)

    Ngo, J.C.; Huang, M.; Roth, D.A.; Furie, B.C.; Furie, B. (Wyeth); (MBL)

    2008-06-03

    Factor VIII is a procofactor that plays a critical role in blood coagulation, and is missing or defective in hemophilia A. We determined the X-ray crystal structure of B domain-deleted human factor VIII. This protein is composed of five globular domains and contains one Ca{sup 2+} and two Cu{sup 2+} ions. The three homologous A domains form a triangular heterotrimer where the A1 and A3 domains serve as the base and interact with the C2 and C1 domains, respectively. The structurally homologous C1 and C2 domains reveal membrane binding features. Based on biochemical studies, a model of the factor IXa-factor VIIIa complex was constructed by in silico docking. Factor IXa wraps across the side of factor VIII, and an extended interface spans the factor VIII heavy and light chains. This model provides insight into the activation of factor VIII and the interaction of factor VIIIa with factor IXa on the membrane surface.

  1. Crystal Structure of Human Factor VIII: Implications for the Formation of the Factor IXa-Factor VIIIa Complex

    Energy Technology Data Exchange (ETDEWEB)

    Chi Ki Ngo,J.; Huang, M.; Roth, D.; Furie, B.; Furie, B.

    2008-01-01

    Factor VIII is a procofactor that plays a critical role in blood coagulation, and is missing or defective in hemophilia A. We determined the X-ray crystal structure of B domain-deleted human factor VIII. This protein is composed of five globular domains and contains one Ca(2+) and two Cu(2+) ions. The three homologous A domains form a triangular heterotrimer where the A1 and A3 domains serve as the base and interact with the C2 and C1 domains, respectively. The structurally homologous C1 and C2 domains reveal membrane binding features. Based on biochemical studies, a model of the factor IXa-factor VIIIa complex was constructed by in silico docking. Factor IXa wraps across the side of factor VIII, and an extended interface spans the factor VIII heavy and light chains. This model provides insight into the activation of factor VIII and the interaction of factor VIIIa with factor IXa on the membrane surface.

  2. Hydrophilic-coated catheter appreciation study in a pediatric population

    Science.gov (United States)

    Boucher, Andréanne; Cloutier, Jonathan; Lebel, Sylvie; Hamel, Micheline; Lamontagne, Pascale; Bolduc, Stéphane

    2010-01-01

    Objective: The objective of the paper was to compare the satisfaction of hydrophilic-coated catheters (HC) (SpeediCath, Coloplast Canada, Mississauga, ON) versus uncoated catheters in a pediatric neurogenic bladder population, in order to identify a target group for HC. The main hypothesis was that our patients, with regard to their limitations, might have difficulties using the HC. Material and methods: A comparative prospective study was initiated in one pediatric rehabilitation centre. Out of the 39 patients who tried the HC during a routine clinic visit, 31 patients/parents accepted to participate in a 1-week trial and to answer a satisfaction questionnaire. Their medical records were reviewed for age, neurological disease, intellectual deficit, impaired dexterity and method of catheterization (Mitrofanoff/urethra). Results: Thirty of the 31 patients answered the satisfaction questionnaire. The median age for the 30 patients was 13.5 years (range 6–20 years). Of these patients, 19 were females (63%), 26 performed self-catheterization (87%), and 6 had Mitrofanoff (20%). Ten children (33%) would be ready to proceed with HC and all 10 children would receive catheterization by the urethra. Of these, 9 were females (90%), 8 used compact-HC (80%) and all were self-sufficient. Patients using compact-HC would continue with this catheter. In the patient comments, males catheterizing per-urethra and patients using a continent stoma requiring long catheters had problems with the excess of lubricant. Conclusion: Most children preferred their usual uncoated catheter and would not change for HC. Female patients catheterizing per-urethra with a compact-HC seem to benefit most from this catheter. PMID:21749816

  3. Analysis of inversions in the factor VIII gene in Spanish hemophilia A patients and families

    Energy Technology Data Exchange (ETDEWEB)

    Domenech, M.; Tizzano, E.; Baiget, M. [Hospital de Sant Pau, Barcelona (Spain); Altisent, C. [Hospital Vall d`Hebron, Barcelona (Spain)

    1994-09-01

    Intron 22 is the largest intron of the factor VIII gene and contains a CpG island from which two additional transcripts originate. One of these transcripts corresponds to the F8A gene which have telomeric extragenic copies in the X chromosome. An inversion involving homologous recombination between the intragenic and the distal or proximal copies of the F8A gene has been recently described as a common cause of severe hemophilia A (HA). We analyzed intron 22 rearrangements in 195 HA patients (123 familial and 72 sporadic cases). According to factor VIII levels, our sample was classified as severe in 114 cases, moderate in 29 cases and mild in 52 cases. An intron 22 (F8A) probe was hybridized to Southern blots of BcII digested DNA obtained from peripheral blood. A clear pattern of altered bands identifies distal or proximal inversions. We detected an abnormal pattern identifying an inversion in 49 (25%) of the analyzed cases. 43% of severe HA patients (49 cases) showed an inversion. As expected, no inversion was found in the moderate and mild group of patients. We found a high proportion (78%) of the distal rearrangement. From 49 identified inversions, 33 were found in familial cases (27%), while the remaining 15 were detected in sporadic patients (22%) in support that this mutational event occurs with a similar frequency in familial or sporadic cases. In addition, we detected a significant tendency of distal inversion to occur more frequently in familial cases than in sporadic cases. Inhibitor development to factor VIII was documented in approximately 1/3 of the patients with inversion. The identification of such a frequent molecular event in severe hemophilia A patients has been applied in our families to carrier and prenatal diagnosis, to determine the origin of the mutation in the sporadic cases and to detect the presence of germinal mosaicism.

  4. AKTIVITAS FISIK, ASUPAN ENERGI DAN STATUS GIZI WANITA PEMETIK TEH DI PTPN VIII BANDUNG, JAWA BARAT

    Directory of Open Access Journals (Sweden)

    Venny Agustiani Mahardikawati

    2012-03-01

    Full Text Available 800x600 Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Quality of human resources is very important to improve productivity. The worker productivity is correlated with nutritional status and health status. The objective of the research is to analyze physical activity, energy intake, nutritional status, of women workers at Tea Plantation PTPN VIII Bandung, West Java. The cross sectional design was used in this study to elaborate physical activity, nutritional status, and productivity of tea picker’s women. The criteria of study sample were tea picker’s women at cluster area of Malabar tea plantation of PTPN VIII Bandung, having infant and they were willing to be interviewed. The total number of 92 women sample was chosen randomly. Primary data consisted of physical activity recall (2x24 hours, food consumption recall (2x24 hours, anthropometry data (weight and height, and productivity (passage of tea sprout. Secondary data were included data of PT Perkebunan Nusantara VIII Bandung, West Java. The result showed that more than a half of samples having active or moderate physical activity level (PAL. The physical activity level of samples during work day (average PAL=1.87 was higher than holiday (average PAL=1.69 (p2362 kcal and 2134 kcal. The average energy adequacy level during workday and day off according to Schofield and Oxford equation were not significantly different, respectively 97,2% and 103,3%. The majority of samples had normal nutritional status, and 30.4% of the sample was overweight. The energy adequacy level according to Schofield and Oxford equation are related to nutritional status of women workers. Keywords: physical activity, energy expenditure, nutritional status, plantation women

  5. Prospects and Challenges of Implementing the Hydrographic Region VIII Basin Plan

    Directory of Open Access Journals (Sweden)

    Nathalia Silva Duarte

    2011-12-01

    Full Text Available The current “National Water Law” states that water resources plans must be elaborated by basins, states, and for the country. This essay discusses the water management process considering federal and state legislations and their interrelations, for the purpose of elucidating the gaps found in them , aiming at their applicability to the system of water resources management within the CBH- Macaé and Ostras scope. It also discusses the construction and evolution process of the above-mentioned committee, and developments in the implementation of the Basin Plan of Hydrographic Region VIII.

  6. Leonor Plantagenet y la consolidación castellana en el reinado de Alfonso VIII

    Directory of Open Access Journals (Sweden)

    Cerda, José Manuel

    2012-12-01

    Full Text Available The kingdom of Castile experienced a process of political and territorial consolidation between the death of Sancho III in 1158 and the Curia of Carrión de los Condes in 1188, leaving behind the troublesome minority of Alfonso VIII and the subordination to the kingdom of Leon, and thus becoming a dominant power within the peninsula, and one that achieved considerable success in the Reconquest. The following article is part of a biographical approach to Eleanor Plantagenet, queen consort of Alfonso VIII, and by means of a specifi c focus offers an analysis of the role played by the English queen in this process of political consolidation of Castile. As we approach the eighth centenary of her death, the life and work of this little-studied woman emerges as a testimony to the important diplomatic and cultural tasks assumed by queens in twelfth-century Europe.

    Desde la muerte de Sancho III en 1158 a la Curia de Carrión de los Condes en 1188, el reino castellano experimentó una consolidación política y territorial que dejó atrás la problemática minoría de Alfonso VIII y la subordinación al reino de León, que lo constituyó en un poder dominante dentro de la península y que logró un avance importante en la empresa reconquistadora. El presente trabajo es parte de un acercamiento biográfico a Leonor Plantagenet, consorte de Alfonso VIII, y que por medio de un enfoque particular ofrece un análisis de la incidencia que tuvo la reina inglesa en este proceso de afianzamiento político de Castilla. En las vísperas del octavo centenario de su muerte, la vida y obra de esta mujer hasta ahora poco estudiada, surge como un testimonio importante a la labor diplomática y cultural que asumían las reinas en la Europa del siglo XII.

  7. IMPLIKASI YURIDIS PUTUSAN MK NOMOR 46/PUU- VIII/ 2010 TERHADAP AKTA KELAHIRAN ANAK LUAR KAWIN

    Directory of Open Access Journals (Sweden)

    Djumikasih Djumikasih

    2014-08-01

    Full Text Available Abstract This paper aims to identify and analyze what the juridical implications of the publication of the decision of the Constitutional Court No. 46/PUU-VIII / 2010 on Child Outside Marriage Deed which has been published by the Department of Population and Civil Registration prior to the establishment of the Constitutional Court's decision . The method used in this study is a normative juridical approach legislation. From the discussion, it can be concluded that the Constitutional Court 46/PUU-VIII/2010 Number of Tests on Article 43 paragraph ( 1 Marriage Act ( Act No. 1 of 1974 when viewed from the angle of legal certainty it will lead to legal certainty . But the decision will not have any juridical implications of the child's birth certificate that has been published outside of marriage and illegitimate child who was born before the date of February 17, 2012, as if enacted would be contrary to the principle of legality is interpreted Article 47 of the Law on the Constitutional Court and Article 28 ( i of the 1945 Constitution . Likewise, if the terms of the fairness and usefulness , especially for justice seekers / applicant , the timing of this decision is not fair and not useful , because although the Court granted the petition but the Constitutional Court can not be applied to her .   Key words: yuridical implication, birth certificate, children who are born outside of marriage   Abstrak   Tulisan ini bertujuan untuk mengetahui dan menganalisis apa implikasi yuridis dari terbitnya putusan MK Nomor 46/PUU-VIII/ 2010 terhadap Akta Anak Luar Kawin yang sudah diterbitkan oleh Dinas Kependudukan dan Catatan Sipil sebelum lahirnya putusan MK tersebut. Metode yang digunakan dalam penelitian ini adalah yuridis normative dengan pendekatan perundang-undangan. Dari pembahasan dapat disimpulkan bahwa Putusan MK Nomer 46/PUU-VIII/2010 tentang Pengujian terhadap Pasal 43 ayat (1 UU Perkawinan (UU NO 1 Tahun 1974 jika dilihat dari sudut kepastian

  8. Grotrian diagrams for highly ionized cobalt Co VIII through Co XXVII

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, Toshizo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sugar, J.; Wiese, W.L.

    1997-07-01

    Grotrian diagrams are presented to provide graphical overviews for 1,247 spectral lines of highly ionized cobalt, Co VIII through Co XXVII. In the usual diagram display such as that by Bashkin and Stoner (North-Holland, Amsterdam, 1975), the density of transitions is often too high to allow each transition to be drawn separately. Here in our modified diagrams, the transitions are also represented by lines connecting the upper and lower energy levels, but the lower energy levels are extended and repeated for successive configurations as needed. As a sequence, dense packing is avoided and all lines in a multiplet can be accommodated. (author)

  9. Comercio Internacional mediterráneo en el siglo VIII a.C.

    Directory of Open Access Journals (Sweden)

    Paloma Cabrera Bonet

    2018-01-01

    Full Text Available The VIII century B.C. saw, for the first time after the breakdown of the system in the Late Bronze Age, the revival of a true intemational trade at a growing scale, especíally protagonized by Phoenicians and Greeks. In this article we analyze sorne aspects of this phenomenon, from the Aegean to the Far West, which made possíble, through a vaste network of trading routes, a large multinational ínteractíon. We understand the international trade as a key factor in the proccess of economic, social and political changes of the Mediterranean areas submerged in this complex "world-system".

  10. Underground Test Area Subproject Phase I Data Analysis Task. Volume VIII - Risk Assessment Documentation Package

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-12-01

    Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

  11. Isidore of Seville and comici ueteres. Ad Isid., Orig. VIII 7.7

    Directory of Open Access Journals (Sweden)

    Krzysztof Rzepkowski

    2012-12-01

    Full Text Available In chapter 7 of book VIII of Etymologies dedicated to Roman poets (De poetis, Isidore draws a dividing line between the so-called ueteres and noui comici. Among ueteres he counts Plautus, Accius, Terentius, although Accius, according to our knowledge, composed only tragedies and can hardly be considered a comic playwright. In this paper I try to prove that all the palaeographic, phonetic, historical, and literary arguments speak in favour of emending in the discussed passage the peculiar «Accius» to the expected «Caecilius» (i.e. Caecilius Statius.

  12. Molecular characterization of a novel family VIII esterase from burkholderia multivorans UWC10

    CSIR Research Space (South Africa)

    Rashamuse, KJ

    2007-02-01

    Full Text Available et al., 1992). Here we report the cloning, purification, and 3D model of a novel family VIII esterase from Burkholderia multivorans UWC10. To our knowledge no report of esterolytic activity from B. multivorans is currently available. METHODOLOGY... stream_source_info Rashamuse1_2007_d.pdf.txt stream_content_type text/plain stream_size 9884 Content-Encoding UTF-8 stream_name Rashamuse1_2007_d.pdf.txt Content-Type text/plain; charset=UTF-8 Molecular Characterization...

  13. Estudo da articulação temporomandibular em camundongos deficientes de fator VIII

    OpenAIRE

    Patricia do Socorro Queiroz Feio

    2010-01-01

    Resumo: A hemofilia é uma doença hemorrágica hereditária ligada ao cromossomo X, decorrente da ausência ou da baixa quantidade no plasma dos fatores de coagulação Fator VIII (hemofilia A) ou do Fator IX (hemofilia B). Clinicamente, a hemofilia se caracteriza por episódios recorrentes de sangramentos profundos, que podem ocorrer espontaneamente ou em decorrência de traumatismos. O sistema músculo-esquelético é freqüentemente afetado pelos eventos hemorrágicos nos pacientes portadores de hemofi...

  14. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    Science.gov (United States)

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  15. Spontaneous migration of central venous catheter tip following extubation

    Directory of Open Access Journals (Sweden)

    Balaji Prabaharan

    2014-01-01

    Full Text Available Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

  16. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    Science.gov (United States)

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  17. CT imaging of complications of catheter ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Shroff, G.S.; Guirguis, M.S.; Ferguson, E.C.; Oldham, S.A.A.; Kantharia, B.K.

    2014-01-01

    The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation

  18. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  19. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won

    1996-01-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications

  20. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  1. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  2. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  3. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  4. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  5. Seismic instrumentation

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The aim of this RFS is to define the type, location and operating conditions for seismic instrumentation needed to determine promptly the seismic response of nuclear power plants features important to safety to permit comparison of such response with that used as the design basis

  6. Meteorological instrumentation

    International Nuclear Information System (INIS)

    1982-06-01

    RFS or ''Regles Fondamentales de Surete'' (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety , while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the ''Service Central de Surete des Installations Nucleaires'' or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The purpose of this RFS is to specify the meteorological instrumentation required at the site of each nuclear power plant equipped with at least one pressurized water reactor

  7. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  8. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  9. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  10. Role of VI/II ratio on the growth of ZnO nanostructures using chemical bath deposition

    Energy Technology Data Exchange (ETDEWEB)

    Urgessa, Z.N., E-mail: zelalem.urgessa@nmmu.ac.za [Department of Physics, P.O. Box 77000, Nelson Mandela Metropolitan University, Port Elizabeth 6031 (South Africa); Oluwafemi, O.S. [Department of Chemistry and Chemical Technology, Walter Sisulu University, Mthatha Campus, Private Bag XI, 5117 (South Africa); Botha, J.R. [Department of Physics, P.O. Box 77000, Nelson Mandela Metropolitan University, Port Elizabeth 6031 (South Africa)

    2012-05-15

    In this paper the growth process and morphological evolution of ZnO nanostructures were investigated in a series of experiments using chemical bath deposition. The experimental results indicate that the morphological evolution depends on the reaction conditions, particularly on OH{sup -} to Zn{sup 2+} ratio (which directly affects the pH). For low VI/II ratios, quasi-spherical nanoparticles of an average diameter 30 nm are obtained, whereas for larger VI/II ratios, nanorods with an average diameter less than 100 nm are produced, which indicates that by systematically controlling the VI/II ratio, it is possible to produce different shapes and sizes of ZnO nanostructures. A possible mechanism for the nanostructural change of the as-synthesized ZnO from particle to rod was elucidated based on the relative densities of H{sup +} and OH{sup -} in the solution.

  11. Role of VI/II ratio on the growth of ZnO nanostructures using chemical bath deposition

    International Nuclear Information System (INIS)

    Urgessa, Z.N.; Oluwafemi, O.S.; Botha, J.R.

    2012-01-01

    In this paper the growth process and morphological evolution of ZnO nanostructures were investigated in a series of experiments using chemical bath deposition. The experimental results indicate that the morphological evolution depends on the reaction conditions, particularly on OH − to Zn 2+ ratio (which directly affects the pH). For low VI/II ratios, quasi-spherical nanoparticles of an average diameter 30 nm are obtained, whereas for larger VI/II ratios, nanorods with an average diameter less than 100 nm are produced, which indicates that by systematically controlling the VI/II ratio, it is possible to produce different shapes and sizes of ZnO nanostructures. A possible mechanism for the nanostructural change of the as-synthesized ZnO from particle to rod was elucidated based on the relative densities of H + and OH − in the solution.

  12. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  13. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  14. Peripherally inserted central catheters in infants and children - indications, techniques, complications and clinical recommendations

    DEFF Research Database (Denmark)

    Westergaard, B; Classen, V; Walther-Larsen, S

    2013-01-01

    of perioperative complications. Assisted visualisation, preferably with ultrasound, yields high rates of insertion success. With good catheter care, rates of mechanical, infectious and thrombotic complications are low and compare favourably with those of traditional central venous catheters. Even in the case...... of occlusion or infection, fibrinolytics and antibiotic locks often allow the catheter to be retained....

  15. Percutaneous transvenous retrieval of CVP catheter emboli in S. V. C.-A case report-

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Lee, Deock Hee; Kim, Hong; Kim, Ok Bae

    1987-01-01

    The increasing use of the indwelling venous catheters and cardiovascular catheters has led to many iatrogenic complications. One of the most serious complications is catheter embolization, caused by inadvertent fracture of a fragment of catheter remaining within cardiovascular systems. In the catheter embolization, there are serious consequence such as thromboembolism, sepsis, cardiac arrhythmia and others. Fisher and Ferreyro (1978) reported a 71% incidence of serious morbidity or death following to intravascular foreign bodies in patients without removal. The authors experienced a case of retained central venous pressure monitoring catheter (CVP catheter) fragment extending from superior vena cava to hepatic segment of inferior vena cava. CVP catheter wa introduced into right subclavian venous route for hyperalimentation, because of poor general condition for operation of afferent loop syndrome following to resection of the gastric carcinoma with Billoth II operation (5 years age). On attempting removal of CVP catheter on recovery from afferent loop syndrome, a large portion of the CVP catheter was cut off in S.V.C. Percutaneous puncture of right femoral vein with Seldinger technique was done and 9F introducer sheath was indwelled. The helical basket of Dotter intravascular retriever set was advance through the sheath up to retained CVP catheter, and it was grasped. The retrieved CVP catheter fragment showed several tiny blood clots on surface. The patient was uneventfully recovered and was discharged asymptomatic on second day of the procedure.

  16. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  17. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal.

    Science.gov (United States)

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-08-08

    to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. investigar a incidência de flebites e a associação de fatores de risco com a sua ocorrência durante o uso e após a retirada do cateter intravenoso periférico - CIP (Flebite pós-infusão) em adultos hospitalizados. estudo de coorte com 171 pacientes com CIP, totalizando 361 punções. Foram coletadas variáveis sociodemográficas e relacionadas ao cateter. Análise estatística descritiva e analítica. dos pacientes, 51,5% eram homens e a média de idade foi de 56,96 anos. A incidência de flebites durante o uso do CIP foi de 1,25% e a pós-infusão foi de 1,38%. Associou-se à flebite durante o uso do CIP ao tempo de permanência do

  18. The sliding rail system (monorail): description of a new technique for intravascular instrumentation and its application to coronary angioplasty.

    Science.gov (United States)

    Bonzel, T; Wollschläger, H; Kasper, W; Meinertz, T; Just, H

    1987-01-01

    The sliding rail technique is a new technique for intravascular instrumentation, especially coronary stenosis dilatation. The so-called monorail balloon catheter is the first device which can be used according to this technique. The monorail catheter has a single lumen shaft and only a short central tube within the distal balloon part. With the guidewire inserted into the tube, the balloon can be advanced or retracted on the guidewire as on a sliding rail. The most relevant improvements for coronary dilatation are steerability, contrast flow and rapid and easy exchangeability of balloon catheters and other intracoronary devices. These characteristics are felt to result in a more simple and time- and fluoroscopy-saving dilatation procedure. A special transfusion catheter may also improve procedural safety. The first clinical results in 69 patients with a success rate of 96%, an emergency bypass rate of two patients (one infarction) and a stenosis improvement of 58% confirm the theoretically conceived advantages.

  19. Radiological instrument

    International Nuclear Information System (INIS)

    Kronenberg, S.; McLaughlin, W.L.; Seibentritt, C.R. Jr.

    1986-01-01

    An instrument is described for measuring radiation, particularly nuclear radiation, comprising: a radiation sensitive structure pivoted toward one end and including a pair of elongated solid members contiguously joined together along their length dimensions and having a common planar interface therebetween. One of the pairs of members is comprised of radiochromic material whose index of refraction changes due to anomolous dispersion as a result of being exposed to nuclear radiation. The pair of members further has mutually different indices of refraction with the member having the larger index of refraction further being transparent for the passage of light and of energy therethrough; means located toward the other end of the structure for varying the angle of longitudinal elevation of the pair of members; means for generating and projecting a beam of light into one end of the member having the larger index of refraction. The beam of light is projected toward the planar interface where it is reflected out of the other end of the same member as a first output beam; means projecting a portion of the beam of light into one end of the member having the larger index of refraction where it traverses therethrough without reflection and out of the other end of the same member as a second output beam; and means adjacent the structure for receiving the first and second output beams, whereby a calibrated change in the angle of elevation of the structure between positions of equal intensity of the first and second output beams prior to and following exposure provides a measure of the radiation sensed due to a change of refraction of the radiochromic material

  20. KEANEKARAGAMAN HYMENOPTERA PARASITOID PADA PERKEBUNAN KELAPA SAWIT PTPN VIII CINDALI, BOGOR

    Directory of Open Access Journals (Sweden)

    Ichsan Luqmana Indra Putra

    2016-09-01

    Full Text Available Diversity of parasitic Hymenoptera in PTPN VIII oil palm plantation Cindali, Bogor. One group of important natural enemies in oil palm plantation is parasitic Hymenoptera. The purpose of this research is to know the diversity and fluctuation of parasitic Hymenoptera PTPN VIII Cindali oil palm plantation. This research was conducted in 6 blocks of oil palm in September 2014 – June 2015. There were 5 plots in every observation blocks 39.2 x 39.2 m in size, and used direct and indirect method. Direct method done by 5 plants in every plots was taken randomized to observed and taken the herbivore insects to reared until the parasitic Hymenoptera came out. Observation of cover crops conducted by 3 subplots determined diagonally in every plots 9.8 x 9.8 m in size and herbivore insects was observed and collected. Indirect methods used sweep net and yellow pan trap. The result of this research, 26 parasitic Hymenoptera families was found, with the Braconidae was the most morphospecies found and the most individual amount was Scelionidae. The abundance of parasitoid in every month fluctuated.

  1. Innovative Approaches for Immune Tolerance to Factor VIII in the Treatment of Hemophilia A

    Science.gov (United States)

    Sherman, Alexandra; Biswas, Moanaro; Herzog, Roland W.

    2017-01-01

    Hemophilia A (coagulation factor VIII deficiency) is a debilitating genetic disorder that is primarily treated with intravenous replacement therapy. Despite a variety of factor VIII protein formulations available, the risk of developing anti-dug antibodies (“inhibitors”) remains. Overall, 20–30% of patients with severe disease develop inhibitors. Current clinical immune tolerance induction protocols to eliminate inhibitors are not effective in all patients, and there are no prophylactic protocols to prevent the immune response. New experimental therapies, such as gene and cell therapies, show promising results in pre-clinical studies in animal models of hemophilia. Examples include hepatic gene transfer with viral vectors, genetically engineered regulatory T cells (Treg), in vivo Treg induction using immune modulatory drugs, and maternal antigen transfer. Furthermore, an oral tolerance protocol is being developed based on transgenic lettuce plants, which suppressed inhibitor formation in hemophilic mice and dogs. Hopefully, some of these innovative approaches will reduce the risk of and/or more effectively eliminate inhibitor formation in future treatment of hemophilia A. PMID:29225598

  2. PENERAPAN MODEL PEMBELAJARAN BAKULIKAN UNTUK MENINGKATKAN KEMAMPUAN BERSIKAP ILMIAH PADA KONSEP PEMANTULAN CAHAYA KELAS VIII

    Directory of Open Access Journals (Sweden)

    N. A. Shofiah

    2012-01-01

    Full Text Available Penelitian tindakan kelas yang bertujuan untuk meningkatkan kemampuan bersikap ilmiah, telah dilakukan di kelas VIII semester IIpada sub pokok bahasan pemantulan cahaya. Untuk meningkatkan kemampuan bersikap ilmiah diterapkan model pembelajaranbakulikan. Penelitian tindakan kelas ini terdiri dari tiga sikus, dengan masing-masing siklus terdiri dari empat tahapan yaituperencanaan, pelaksanaan, observasi dan refleksi. Data sikap ilmiah siswa diambil dari lembar angket dan lembar observasi. Datahasil belajar kognitif diambil dari evaluasi yang ada di LKS tiap akhir siklus dan data hasil belajar psikomotorik diambil dari lembarobservasi tiap akhir siklus. Hasil penelitian menyatakan bahwa sikap ilmiah siswa mengalami peningkatan walaupun tidaksignifikan. Hasil belajar kognitif dan keterampilan psikomotorik siswa mengalami peningkatan tiap siklus dan mencapai ketuntasanpada siklus III. A classroom action research aimed to improve scientific attitude skill had been done in second semester of grade VIII MTs on thesubtopic light reflection. The 'bakulikan' learning model was chosen for improving the scientific attitude skills of the students. Thisaction research consisted of three cycles, and each cycle has four stages, namely, planning, conducting, observation andreflection. The data obtained through questionnaire and observation sheets. The cognitive achievement drawn from the evaluationon each worksheet at the end of each cycle, and the psychometrics recorded from observation sheet. The study concludes that thescientific attitude skill improved significantly. The achievement on cognitive and psychometrics increase gradually on each cycleand get mastery at the end of the last cycle.Keywords: bakulikan; classroom action research; scientific attitude

  3. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  4. Chronic Obstructive Pulmonary Disease in Patients with Catheter ...

    African Journals Online (AJOL)

    of COPD in CAD patients. Methods: A cross sectional study that included consecutive adults with catheter diagnosed CAD recruited from two cardiac centers. Patients completed a COPD diagnosis validated questionnaire and performed spirometry using an electronic spirometer. COPD was diagnosed if patient score placed ...

  5. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  6. EVALUATION OF A NEW CATHETER FOR ESOPHAGEAL PH MONITORING

    NARCIS (Netherlands)

    KUIT, JA; SCHEPEL, SJ; BIJLEVELD, CMA; KLEIBEUKER, JH

    A new catheter, provided with an Ion Sensitive Field Effect Transistor as a pH sensor and incorporating a reference electrode, was evaluated for esophageal pH recording. The pH-sensitivity was 54 mV/pH in vitro, with a linear response between pH 2 and pH 9. Clinical semi-ambulatory 24-hour

  7. Anatomical and procedural determinants of catheter-based renal denervation

    NARCIS (Netherlands)

    Ewen, Sebastian; Ukena, Christian; Lüscher, Thomas Felix; Bergmann, Martin; Blankestijn, Peter J; Blessing, Erwin; Cremers, Bodo; Dörr, Oliver; Hering, Dagmara; Kaiser, Lukas; Nef, Holger; Noory, Elias; Schlaich, Markus; Sharif, Faisal; Sudano, Isabella; Vogel, Britta; Voskuil, Michiel; Zeller, Thomas; Tzafriri, Abraham R; Edelman, Elazer R; Lauder, Lucas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2016-01-01

    BACKGROUND/PURPOSE: Catheter-based renal sympathetic denervation (RDN) can reduce blood pressure (BP) and sympathetic activity in certain patients with uncontrolled hypertension. Less is known about the impact of renal anatomy and procedural parameters on subsequent BP response. METHODS/MATERIALS: A

  8. Prophylactic ciprofloxacin for catheter-associated urinary-tract infection

    NARCIS (Netherlands)

    Wall, E. van der; Verkooyen, R.P.; Mintjes-de Groot, J.; Oostinga, J.; Dijk, Arie van; Hustinx, W.N.M.; Verbrugh, H.A.

    1992-01-01

    Patients receiving antibiotics during bladder drainage have a lower incidence of urinary-tract infections compared with similar patients not on antibiotics. However, antibiotic prophylaxis in patients with a urinary catheter is opposed because of the fear of inducing resistant bacterial strains. We

  9. Bi-layer sandwich film for antibacterial catheters.

    Science.gov (United States)

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  10. Bi-layer sandwich film for antibacterial catheters

    Directory of Open Access Journals (Sweden)

    Gerhard Franz

    2017-09-01

    Full Text Available Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters.Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene. This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition.Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier.

  11. A Tight Spot After Pulmonary Vein Catheter Ablation

    NARCIS (Netherlands)

    Amir, Rabia; Yeh, Lu; Montealegre-Gallegos, Mario; Saraf, Rabya; Matyal, Robina; Mahmood, Feroze

    2016-01-01

    A 52-YEAR-OLD woman with a history of embolic stroke due to paroxysmal atrial fibrillation was referred to the authors’ institution for epicardial surgical pulmonary vein isolation with left atrial appendage resection. The patient had 2 previous failed pulmonary vein catheter ablations. Dense

  12. Use of urethral catheters for diagnostic peritoneal lavage in blunt ...

    African Journals Online (AJOL)

    Background: Diagnostic peritoneal lavage (DPL) has been reported to be a reliable diagnostic tool in assessing the need for liparotomy in blunt abdominal trauma (BAT) with a diagnostic accuracy of more thin 95% when using a peritoneal lavage catheter (PLC). The aim of this study was to determine the diagnostic ...

  13. Management of non-catheter-associated complicated urinary tract infection.

    Science.gov (United States)

    Dielubanza, Elodi J; Mazur, Daniel J; Schaeffer, Anthony J

    2014-03-01

    This article presents an overview of non-catheter-associated complicated urinary tract infection (UTI) from a urologic point of view. Discussion includes the evaluation and workup a complicated UTI through history, physical examination, laboratory analysis, and radiographic studies. Specific types of complicated UTI, such as urinary obstruction and renal abscess, are reviewed. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  15. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... They have been shown to lower the risk of catheter colonisation and CRBSI in critically ill patients.42,43 The anti-infective effect is short-lived, however, as the collagen to which the silver ions are chelated is biodegradable. Other drawbacks include cost and the need for specialised training. Antiseptic hubs.

  16. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  17. 21 CFR 870.1210 - Continuous flush catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... that permits continuous intravascular flushing at a slow infusion rate for the purpose of eliminating...

  18. Preventing Inadvertent Placement of Foley Catheter into Prostatic ...

    African Journals Online (AJOL)

    Percutaneous suprapubic trocar cystostomy (SPC) is often needed to drain the bladder when urethral catheterization either fails or is not advisable.[1] It is ... vertical or slightly tilting its tip toward umbilicus during foley placement, prevents the inadvertent migration of catheter into prostatic urethra and further complications.

  19. Catheter ablation as a treatment of atrioventricular block.

    Science.gov (United States)

    Tuohy, Stephen; Saliba, Walid; Pai, Manjunath; Tchou, Patrick

    2018-01-01

    Symptomatic second-degree atrioventricular (AV) block is typically treated by implantation of a pacemaker. An otherwise healthy AV conduction system can nevertheless develop AV block due to interference from junctional extrasystoles. When present with a high burden, these can produce debilitating symptoms from AV block despite an underlying normal AV node and His-Purkinje system properties. The purpose of this study was to describe a catheter ablation approach for alleviating symptomatic AV block due to a ventricular nodal pathway interfering with AV conduction. Common clinical monitoring techniques such as Holter and event recorders were used. Standard electrophysiological study techniques using multipolar recording and ablation catheters were utilized during procedures. A 55-year-old woman presented with highly symptomatic, high-burden second-degree AV block due to concealed and manifest junctional premature beats. Electrophysiological characteristics indicated interference of AV conduction due to a concealed ventricular nodal pathway as the cause of the AV block. The patient's AV nodal and His-Purkinje system conduction characteristics were otherwise normal. Radiofrequency catheter ablation of the pathway was successful in restoring normal AV conduction and eliminating her clinical symptoms. Pathways inserting into the AV junction can interfere with AV conduction. When present at a high burden, this type of AV block can be highly symptomatic. Catheter ablation techniques can be used to alleviate this type of AV block and restore normal AV conduction. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. 21 CFR 884.6110 - Assisted reproduction catheters.

    Science.gov (United States)

    2010-04-01

    ... vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction catheters. 884.6110 Section 884.6110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  1. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    Jul 5, 2012 ... Successful management of parotid duct injury depends on early diagnosis and appropriate intervention, failing of ... Mansarovar Dental College Hospital and Research Centre,. Kolar Road ... A 42-year-old male patient presented to maxillofacial .... catheter, catgut suture, and pediatric intravascular cannula.

  2. Anchor balloons assisted deep intubation of 5F catheters for ...

    African Journals Online (AJOL)

    2015-07-24

    Jul 24, 2015 ... However, cardiologists still encounter some difficult scenarios such as variant coronary artery origins, severely calcified and ... Medical University, 300, Guangzhou Road, Nanjing,. Jiangsu .... (l) The ST segment elevated while the 5F catheter was inserted into the proximal left anterior descending artery d.

  3. 46 CFR 54.01-2 - Adoption of division 1 of section VIII of the ASME Boiler and Pressure Vessel Code.

    Science.gov (United States)

    2010-10-01

    ... Boiler and Pressure Vessel Code. 54.01-2 Section 54.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND... division 1 of section VIII of the ASME Boiler and Pressure Vessel Code. (a) Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the ASME Boiler and Pressure Vessel...

  4. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  5. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  6. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Reinnervation following catheter-based radio-frequency renal denervation.

    Science.gov (United States)

    Booth, Lindsea C; Nishi, Erika E; Yao, Song T; Ramchandra, Rohit; Lambert, Gavin W; Schlaich, Markus P; May, Clive N

    2015-04-20

    What is the topic of this review? Does catheter-based renal denervation effectively denervate the afferent and efferent renal nerves and does reinnervation occur? What advances does it highlight? Following catheter-based renal denervation, the afferent and efferent responses to electrical stimulation were abolished, renal sympathetic nerve activity was absent, and levels of renal noradrenaline and immunohistochemistry for tyrosine hydroxylase and calcitonin gene-related peptide were significantly reduced. By 11 months after renal denervation, both the functional responses and anatomical markers of afferent and efferent renal nerves had returned to normal, indicating reinnervation. Renal denervation reduces blood pressure in animals with experimental hypertension and, recently, catheter-based renal denervation was shown to cause a prolonged decrease in blood pressure in patients with resistant hypertension. The randomized, sham-controlled Symplicity HTN-3 trial failed to meet its primary efficacy end-point, but there is evidence that renal denervation was incomplete in many patients. Currently, there is little information regarding the effectiveness of catheter-based renal denervation and the extent of reinnervation. We assessed the effectiveness of renal nerve denervation with the Symplicity Flex catheter and the functional and anatomical reinnervation at 5.5 and 11 months postdenervation. In anaesthetized, non-denervated sheep, there was a high level of renal sympathetic nerve activity, and electrical stimulation of the renal nerve increased blood pressure and reduced heart rate (afferent response) and caused renal vasoconstriction and reduced renal blood flow (efferent response). Immediately after renal denervation, renal sympathetic nerve activity and the responses to electrical stimulation were absent, indicating effective denervation. By 11 months after denervation, renal sympathetic nerve activity was present and the responses to electrical stimulation

  8. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. CENTRAL VENOUS CATHETER AS A VASCULAR APPROACH TO HEMODIALYSTS

    Directory of Open Access Journals (Sweden)

    Verica Djordjevic

    2001-03-01

    Full Text Available The application of the central venous catheter (CVC as a temporary orpermanent vascular approach to hemodialysis has been practiced in our Center since1994. So far 30 (12,6% patients have been thus treated. The primary application hasbeen done in 25 patients, namely: the first making of the A V fistula has been done in16, the ABT in 6, while the vascular approach correction in 3 patients. The secondaryapplication has been done in 5 patients. The infection episode incidence concerningthe CVC application is 20 infections per 1.000 patients. This is the upper limitaccording to the data given in the literature (5, rang 3-20. The average duration of thecatheter is 21 + - 13 days (rang 1-47. Two-volume catheters have been used for ajugular approach though less often for a femoral one. The unsuccessful placing due tothe catheter thrombosis has occurred in 4 patients, the catheter drop-out and itsreplacing have been done in 2 patients, while no replacement has happened in onečaše. The treatment has been stopped in one patient. Tn four patients the cerebrovascularinsult has happened after placing the CVC. The mortality rate is 26,6%,that is, K patients, namely: 4 due to cerebrovascular insult, one due to lung emboly,one due to heart weakness and one due to the sepsis from the V fistula. One patientdied at home for unknown reason. A high infection episode incidence rate is related toinadequate patients' placing so that their location in the rooms for intensive care is away of reducing it. It is necessary to provide for general aseptic procedure at work aswell as for betterment of the accompanying procedures (hemoculture, antibiograms,sterilization in order to maintain a safe catheter function.

  10. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  11. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter.

    Science.gov (United States)

    Wasmer, K; Foraita, P; Leitz, P; Güner, F; Pott, C; Lange, P S; Eckardt, L; Mönnig, G

    2016-01-01

    Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode 1 and 10 interaction and uninterrupted anticoagulation, whereas contact force sensing for iRF might minimize pericardial effusion. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  12. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  13. Purification and characterization of factor VIII 1,689-Cys: a nonfunctional cofactor occurring in a patient with severe hemophilia A.

    Science.gov (United States)

    O'Brien, D P; Tuddenham, E G

    1989-06-01

    We have purified the factor VIII from a CRM+ Hemophilia A plasma (90 U/dL VIII:Ag but 0 U/dL VIII:C) and analyzed the protein before and after thrombin activation by Western blotting with monoclonal antibodies (MoAbs). Normal or patient citrated plasma was ultracentrifuged, cryo-ethanol-precipitated and chromatographed on Sepharose 6B. The void volume fractions were reduced and subjected to ion exchange chromatography yielding material of specific activity approximately 1,000 U/mg protein (VIII:C or VIII:Ag). Factor VIII purified in this way from normal plasma is fully activatable by thrombin with proteolytic fragmentation as previously described by F. Rotblat et al (Biochemistry 24: 4294, 1985). Factor VIII 1,689-Cys has the normal distribution of factor VIII light and heavy chains prior to thrombin activation. After exposure to thrombin the heavy chain polypeptides were fully proteolysed but the light chain was totally resistant to cleavage. This is consistent with the demonstration in the patient's leucocyte DNA of a C to T transition in codon 1,689 converting Arg to Cys at the light chain thrombin cleavage site as previously described by J. Gitschier et al (Blood 72:1022, 1988). Uncleaved light chain of Factor VIII 1,689-Cys is not released from von Willebrand factor (vWF) by thrombin, but this is not the sole cause of the functional defect since the protein purified free of vWF has no coagulant activity. We conclude that the functional defect in factor VIII 1,689-Cys is a consequence of failure to release the acidic peptide from the light chain upon thrombin activation.

  14. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    Science.gov (United States)

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  15. Accuracy of image-guided radiotherapy of prostate cancer based on the BeamCath urethral catheter technique

    DEFF Research Database (Denmark)

    Poulsen, Per Rugaard; Fokdal, Lars; Petersen, Jørgen B.B.

    2007-01-01

    BACKGROUND AND PURPOSE: To examine the accuracy of the BeamCath urethral catheter technique for prostate localization during radiotherapy. MATERIALS AND METHODS: Sixty-four patients were CT scanned twice with the BeamCath catheter, and once without the catheter. The catheter contains radiopaque...

  16. Analysis of factor VIII gene inversions in 164 unrelated hemophilia A families

    Energy Technology Data Exchange (ETDEWEB)

    Vnencak-Jones, L.; Phillips, J.A. III; Janco, R.L. [Vanderbilt Univ. School of Medicine, Nashville, TN (United States)] [and others

    1994-09-01

    Hemophilia A is an X-linked recessive disease with variable phenotype and both heterogeneous and wide spread mutations in the factor VIII (F8) gene. As a result, diagnostic carrier or prenatal testing often relies upon laborious DNA linkage analysis. Recently, inversion mutations resulting from an intrachromosomal recombination between DNA sequences in one of two A genes {approximately}500 kb upstream from the F8 gene and a homologous A gene in intron 22 of the F8 gene were identified and found in 45% of severe hemophiliacs. We have analyzed banked DNA collected since 1986 from affected males or obligate carrier females representing 164 unrelated hemophilia A families. The disease was sporadic in 37%, familial in 54% and in 10% of families incomplete information was given. A unique deletion was identified in 1/164, a normal pattern was observed in 110/164 (67%), and 53/164 (32%) families had inversion mutations with 43/53 (81%) involving the distal A gene (R3 pattern) and 10/53 (19%) involving the proximal A gene (R2 pattern). While 19% of all rearrangements were R2, in 35 families with severe disease (< 1% VIII:C activity) all 16 rearrangements seen were R3. In 18 families with the R3 pattern and known activities, 16 (89%) had levels < 1%, with the remaining 2 families having {le} 2.4% activity. Further, 18 referrals specifically noted the production of inhibitors and 8/18 (45%) had the R3 pattern. Our findings demonstrate that the R3 inversion mutation patterns is (1) only seen with VIII:C activity levels of {le} 2.4%, (2) seen in 46% of families with severe hemophilia, (3) seen in 45% of hemophiliacs known to have inhibitors, (4) not correlated with sporadic or familial disease and (5) not in disequilibrium with the Bcl I or Taq I intron 18 or ST14 polymorphisms. Finally, in families positive for an inversion mutation, direct testing offers a highly accurate and less expensive alternative to DNA linkage analysis.

  17. Keefektifan Experiential Learning Berbantuan Origami Terhadap Kemampuan Keruangan Siswa Kelas VIII

    Directory of Open Access Journals (Sweden)

    Isnaeni Umi Machromah

    2014-11-01

    Full Text Available AbstrakPenelitian eksperimen ini bertujuan untuk mengetahui keefektifan pembelajaran Experiential Learning berbantuan origami terhadap kemampuan keruangan siswa dengan kualifikasi keefektifan yang telah ditentukan. Populasi yaitu siswa kelas VIII SMP Negeri 3 Colomadu tahun pelajaran 2012/2013. Sampel diambil secara simple random sampling. Hasil penelitian ini yaitu: (1 Uji proporsi ketuntasan belajar menunjukkan siswa kelompok eksperimen telah mencapai ketuntasan belajar; (2 Uji perbedaan dua rata-rata menghasilkan simpulan bahwa rata-rata hasil post-test kemam-puan keruangan siswa kelompok eksperimen lebih dari kelompok kontrol; (3 Analisis re-gresi menunjukkan bahwa motivasi belajar siswa memberikan pengaruh positif sebesar 49,3% terhadap kemampuan keruangan siswa; (4 Uji gain ternormalisasi menunjukkan terdapat peningkatan kemampuan keruangan siswa secara signifikan pada kategaori sedang untuk kelompok eksperimen dan kategori rendah untuk kelompok kontrol. Simpulan yang diperoleh yaitu Experiential Learning berbantuan origami efektif terhadap kemampuan keruangan siswa kelas VIII. AbstractThis experiment research aims to determine the effectiveness of Experiential Learning with Origami to the students’s spatial abilities by the criteria of effectiveness. The population of this research is students of grade VIII of SMP Negeri 3 Colomadu 2012/2013 academic year. Independent variables used in this research are learning by Experiential Learning with origami and student’s motivation. While the dependent variable is the student’s spatial abilities. This research is using documentation, spatial abilities’s test, dan motivation’s scale for collecting data method. Result of this research are: (1 proportion test show that the experiment group has reached mastering of learning clasically and personally; (2 result of spatial ablities’s post test in experiment group better than control group; (3 result of regretion shows that student

  18. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  19. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  20. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  1. Factor VIII S373L: mutation at P1' site confers thrombin cleavage resistance, causing mild haemophilia A.

    Science.gov (United States)

    Johnson, D J; Pemberton, S; Acquila, M; Mori, P G; Tuddenham, E G; O'Brien, D P

    1994-04-01

    A novel CRM+ mutation, factor VIII position 373 serine to leucine substitution (FVIII 373-Leu) was identified during a survey of Factor VIII (FVIII) mutations. We have purified the variant protein from the patient's plasma in order to allow further characterisation of the molecule. The CRM+ plasma contained 120% Factor VIII antigen (FVIII:Ag) and 6% Factor VIII coagulant activity (FVIII:C). After purification the mutant FVIII was subjected to thrombin proteolysis, and was thereby activated 5.6-fold compared with 7-fold for wild type molecule. Subsequently, spontaneous inactivation of the mutant was much slower than noted for wild type FVIII. Western blot analysis using monoclonal antibodies demonstrated that thrombin cleavage of FVIII 373-Leu at positions 740 and 1689 were normal but that cleavage at position 372 was completely absent. Crystallographic coordinates of the active site of thrombin complexed to fibrinopeptide A were used to explore possible mechanistic reasons for the failure of thrombin to cleave the mutant FVIII at position 372. Steric hindrance between the mutant side chain and the side chain of the P1 residue was apparent. We conclude that the functional defect of FVIII 373-Leu results from the inability of thrombin to cleave the mutant at position 372-373, and propose that this is due to steric hindrance by the side chain of leucine 373, preventing correct formation of the enzyme substrate complex.

  2. The new albumin-free recombinant factor VIII concentrates for treatment of hemophilia: do they represent an actual incremental improvement?

    Science.gov (United States)

    Josephson, Cassandra D; Abshire, Thomas

    2004-07-01

    The goal of eliminating the low levels of infectious disease risk from hemophilia treatment has resulted in the development of multiple generations of recombinant factor VIII (rFVIII) products. The ideal product should be devoid of human and animal proteins, which may transmit infectious agents. These products should also maintain molecular integrity, hemostatic efficacy, similar immunogenicity, and acceptable side effect profiles as compared to plasma-derived factor VIII. Currently available first-, second-, and third-generation rFVIII products include Recombinate; Kogenate FS/Helixate FS and ReFacto; and Advate, respectively. During the evolution of rFVIII products, either full-length or B-domain-deleted factor VIII were transfected into immortalized cell lines. The B-domain-deleted product, ReFacto, has resulted in an additional method to monitor factor VIII levels. The third-generation products offer the theoretical advantage of being produced without human and/or animal proteins. Upon initial introduction into the marketplace, the newer products have a higher cost. However, when analyzing historical trends, the prices of these products are almost equivalent to first-generation products within 3 years of licensure. Thus, the initial cost of the product may be a minimal issue in the medical decision process when selecting rFVIII replacement therapy.

  3. Break-through bleeding in relation to predicted factor VIII levels in patients receiving prophylactic treatment for severe hemophilia A

    NARCIS (Netherlands)

    Collins, P. W.; Blanchette, V. S.; Fischer, K.; Bjorkman, S.; Oh, M.; Fritsch, S.; Schroth, P.; Spotts, G.; Astermark, J.; Ewenstein, B.

    Background: The role of prophylactic factor VIII (FVIII) to decrease hemophilic bleeding and arthropathy is well established. The rationale for this strategy is to convert patients with severe hemophilia A to a moderate clinical phenotype by reducing time spent with a FVIII level <1 IU dL(-1).

  4. Tranexamic acid combined with recombinant factor VIII increases clot resistance to accelerated fibrinolysis in severe hemophilia A

    DEFF Research Database (Denmark)

    Hvas, Anne-Mette; Sørensen, Hanne Thykjær; Norengaard, Lisbeth

    2007-01-01

    examined whether the clot stability in hemophiliacs could be improved by treatment with tranexamic acid (TXA) in combination with recombinant factor VIII (rFVIII). PATIENTS/METHODS: Baseline blood samples were obtained from eight males with severe hemophilia A. Thereafter, a bolus injection of r...

  5. 75 FR 36426 - Legislative Changes to Nursing Student Loan Program Authorized Under Title VIII of the Public...

    Science.gov (United States)

    2010-06-25

    ... Changes to Nursing Student Loan Program Authorized Under Title VIII of the Public Health Service Act....) 111-148. Section 5202 of the ACA changes the Nursing Student Loan (NSL) program by: (1) Increasing the... degree in nursing. Below are details on how the ACA changes Sections 836(a), 836(b)(1), and 836(b)(3) of...

  6. Chromosome VIII disomy influences the nonsense suppression efficiency and transition metal tolerance of the yeast Saccharomyces cerevisiae.

    Science.gov (United States)

    Zadorsky, S P; Sopova, Y V; Andreichuk, D Y; Startsev, V A; Medvedeva, V P; Inge-Vechtomov, S G

    2015-06-01

    The SUP35 gene of the yeast Saccharomyces cerevisiae encodes the translation termination factor eRF3. Mutations in this gene lead to the suppression of nonsense mutations and a number of other pleiotropic phenotypes, one of which is impaired chromosome segregation during cell division. Similar effects result from replacing the S. cerevisiae SUP35 gene with its orthologues. A number of genetic and epigenetic changes that occur in the sup35 background result in partial compensation for this suppressor effect. In this study we showed that in S. cerevisiae strains in which the SUP35 orthologue from the yeast Pichia methanolica replaces the S. cerevisiae SUP35 gene, chromosome VIII disomy results in decreased efficiency of nonsense suppression. This antisuppressor effect is not associated with decreased stop codon read-through. We identified SBP1, a gene that localizes to chromosome VIII, as a dosage-dependent antisuppressor that strongly contributes to the overall antisuppressor effect of chromosome VIII disomy. Disomy of chromosome VIII also leads to a change in the yeast strains' tolerance of a number of transition metal salts. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Evaluation of the biological differences of canine and human factor VIII in gene delivery: Implications in human hemophilia treatment

    Science.gov (United States)

    The canine is the most important large animal model for testing novel hemophilia A(HA) treatment. It is often necessary to use canine factor VIII (cFIII) gene or protein for the evaluation of HA treatment in the canine model. However, the different biological properties between cFVIII and human FVII...

  8. Successful Retrieval of a Dismembered Central Venous Catheter Stuck to the Right Pulmonary Artery Using a Stepwise Approach

    Directory of Open Access Journals (Sweden)

    Keisuke Nakabayashi

    2016-01-01

    Full Text Available Recent advances in anticancer chemotherapy have resulted in an increase in the number of patients requiring a central venous port catheter, and the incidence of catheter pinch-off syndrome has been increasing. Catheter pinch-off syndrome is a rare and unusual complication. It is difficult to retrieve dislodged catheters from the pulmonary artery, especially if the catheter is stuck to the peripheral pulmonary artery. We herein describe the successful removal of a catheter stuck in the pulmonary artery with a stepwise approach. First, a pigtail catheter was used to tug the dislodged catheter in order to free the unilateral end. Then, a gooseneck snare was used to catch and pull the catheter out of the patient. The key to success is to free the end of the catheter.

  9. Evaluation of Neutron Reactions on Iron Isotopes for CIELO and ENDF/B-VIII.0

    Science.gov (United States)

    Herman, M.; Trkov, A.; Capote, R.; Nobre, G. P. A.; Brown, D. A.; Arcilla, R.; Danon, Y.; Plompen, A.; Mughabghab, S. F.; Jing, Q.; Zhigang, G.; Tingjin, L.; Hanlin, L.; Xichao, R.; Leal, L.; Carlson, B. V.; Kawano, T.; Sin, M.; Simakov, S. P.; Guber, K.

    2018-02-01

    A new suite of evaluations for 54,56,57,58Fe has been developed in the framework of the CIELO international collaboration. New resolved resonance ranges were evaluated for 54Fe and 57Fe, while modifications were applied to resonances in 56Fe. The low energy part of the 56Fe file is almost totally based on measurements. At higher energies in 56Fe and in the whole fast neutron range for minor isotopes the evaluation consists of model predictions carefully adjusted to available experimental data. We also make use of the high quality and well experimentally-constrained dosimetry evaluations from the IRDFF library. Special attention was dedicated to the elastic angular distributions, which were found to affect results of the integral benchmarking. The new set of iron evaluations was developed in concert with other CIELO evaluations and they were tested together in the integral experiments before being adopted for the ENDF/B-VIII.0 library.

  10. MENINGKATKAN TANGGUNG JAWAB SOSIAL SISWA KELAS VIII MELALUI LAYANAN BIMBINGAN KELOMPOK

    Directory of Open Access Journals (Sweden)

    Ummi Farikhatun Nisa

    2012-12-01

    Full Text Available The purpose of this research was to determine the efforts and success in improving students' social responsibility through group counseling services. Type of research used action research. Subjects were 12 students who had low social responsibility and being. Data collection technique used were psychological scales and observation. Data analysis techniques used are non-parametric statistics with the Wilcoxon test. Based on the calculations for the Wilcoxon test, a small amount of levels or Z value was 78.0. While Ztabel for n = 12 with an error level of 5% value is 14. So Z 78.0> 14.0 Ztabel or imply hypothesis accepted. These results demonstrate social responsibility of students prior to obtaining counseling services group at 51.93% (low. After following the guidance services at 81.51% (high. Conclusions from this research is a social responsibility to the students of class VIII SMP Putra Bangsa Bantarkawung increase after getting tutoring services group.

  11. X-ray spectral line coincidences between fluorine VIII (and IX) and transition metal lines

    International Nuclear Information System (INIS)

    Charatis, G.; Rockett, P.D.; Burkhalter, P.G.

    1983-01-01

    X-ray spectroscopy was performed in the 12 to 15 A region, recording L-shell lines from selected laser-irradiated transition metals. Line coincidences and near coincidences were identified between Fe, Cr, Mn, and Ni L-spectra, and F VIII and F IX K-shell lines. Wavelengths were determined to accuracies of 1 to 3 mA and will be utilized in selecting potential pumping candidates in future x-ray lasing schemes. High-resolution x-ray spectra were collected under controlled illumination and target conditions using 1.05 μm and 0.527 μm laser excitation with the KMS CHROMA laser

  12. Symposium by NATO Defense Research Group Panel VIII on Computer-Based Instruction in Military Environments

    CERN Document Server

    Weddle, Peter

    1987-01-01

    This collection of papers is the result of a symposium sponsored by NATO's Defense Research Group Panel VIII in the Spring of 1985. The symposium came into being when it became obvious to the NATO countries that research, development and utilization of advanced technologies for training was the best means of increasing both training effectiveness and efficiency. This symposium was the second in a series of three devoted to training. The series was structured to cover all aspects of training. The first series addressed the value of training, the second one dealt with the application of training technologies and the third and last of the series focused on academic issues concerned with the effect of prior learning on subsequent learning. The fact that a major American publisher has determined that computer based instruction is the technology of greatest interest to the NATO community is not surprising. Advances in microprocessor technology have revolutionized both how and where we train. During this symposium t...

  13. PENERAPAN PENDEKATAN CINEMATHERAPY UNTUK MENINGKATKAN PERILAKU PROSOSIAL PADA SISWA KELAS VIII DI BOSOWA INTERNATIONAL SCHOOL MAKASSAR

    Directory of Open Access Journals (Sweden)

    Haeruddin Niva

    2016-06-01

    Full Text Available The objectives of the research are: (i to know the prosocial behavioral level of the students in Bosowa International School Makassar before and after giving cinematography approach, and (ii to know whether or not the approach is able to enhance the prosocial behavior of the students in Bosowa International School Makassar. The research is a quantitative research using experimental method. The research design used is quasi experimental design with non-equivalent control group design. The data collection technique applied is scale and FGD (Focus Group Discussion. The findings shows that (i the prosocial behavioral level of the students was low in pretest while after giving treatment there were significant increase to the prosocial behavior in the experimental group, and (ii the cinematography approach was able to increase the prosocial behavior of the Grade VIII students in Bosowa Internatinal School Makassar. 

  14. Assessing patients' and caregivers' perspectives on stability of factor VIII products for haemophilia A

    DEFF Research Database (Denmark)

    DiBenedetti, D B; Coles, T M; Sharma, T

    2014-01-01

    Haemophilia A is a rare inherited bleeding disorder characterized by an inability of the blood to clot normally. Patients can experience spontaneous or trauma-induced joint and soft tissue bleeding and must keep coagulation factor VIII (FVIII) accessible at all times; thus, FVIII product storage...... challenges with storing FVIII products, especially storage away from home. More than half preferred storing FVIII products at room temperature vs. in the refrigerator for long periods of time. FVIII product accessibility, usage and storage affect disease management. Results support the need for more...... convenient and accessible FVIII products for patients in daily life and while travelling. In addition, the use of social media has potential value in recruiting this population....

  15. The transitions 4p-5s in Y VI, Zr VII, Nb VIII and Mo IX

    International Nuclear Information System (INIS)

    Chaghtai, M.S.Z.; Rahimullah, K.; Khatoon, S.

    1976-01-01

    With the help of the spectra recorded in the Physics Department of Lund University, Y VI, Zr VII, Nb VIII and Mo IX are freshly analysed. The five 4s 2 4p 4 ground levels and the ten 4s 2 4p 3 5s levels of previous analyses are confirmed in the first three spectra, except for revising in Y VI the 4p 4 1 S 0 and 4p 3 5s( 4 Ssub(3/2)) 2 levels and interchanging 5s( 2 Dsub(3/2)) 1 with 5s( 2 Dsub(3/2)) 2 . All level values are improved due to the new measurements. A new analysis of Mo IX establishing all the 4p 4 and 4p 3 5s levels is being reported. (Auth.)

  16. Factor VIII brand and the incidence of factor VIII inhibitors in previously untreated UK children with severe hemophilia A, 2000-2011

    Science.gov (United States)

    Palmer, Benedict P.; Chalmers, Elizabeth A.; Hart, Daniel P.; Liesner, Ri; Rangarajan, Savita; Talks, Katherine; Williams, Michael; Hay, Charles R. M.

    2014-01-01

    The effect of recombinant factor VIII (rFVIII) brand on inhibitor development was investigated in all 407 severe hemophilia A previously untreated patients born in the United Kingdom (UK) between 1 January 2000 and 31 December 2011. Eighty-eight (22%) had been in the RODIN study. Information was extracted from the National Haemophilia Database. Because exposure days (EDs) were not known for some patients, time from first treatment was used as a surrogate for rFVIII exposure. An inhibitor developed in 118 (29%) patients, 60 high and 58 low titer, after a median (interquartile range) of 7.8 (3.3-13.5) months from first exposure and 16 (9-30) EDs. Of 128 patients treated with Kogenate Bayer/Helixate NexGen, 45 (35.2%, 95% confidence interval [CI] 27.4-43.8) developed an inhibitor compared with 42/172 (24.4%, 95% CI 18.6% to 31.4%) with Advate (P = .04). The adjusted hazard ratio (HR) (95% CI) for Kogenate Bayer/Helixate NexGen compared with Advate was 2.14 (1.12-4.10) (P = .02) for high titer and 1.75 (1.11-2.76) (P = .02) for all inhibitors. When excluding UK-RODIN patients, the adjusted HR (95% CI) for high-titer inhibitors was 2.00 (0.93-4.34) (P = .08). ReFacto AF was associated with a higher incidence of all, but not high-titer, inhibitors than Advate. These results will help inform debate around the relative immunogenicity and use of rFVIII brands. PMID:25339360

  17. [A new port catheter system of aluminum oxide ceramics].

    Science.gov (United States)

    Haindl, H; Schmoll, E; Willmann, G

    1995-03-01

    Implantable port catheter systems are becoming increasingly important, as they often permit out-patient treatment for many indications that would otherwise require hospitalization. Moreover, they also increase the safety/reliability of infusion therapy in critical inpatients. For a variety of reasons, the materials used so far, i.e. steel, titanium and various plastics have not been completely satisfactory. The main disadvantage of metallic systems is the formation of artefacts in tomographic images, while the shortcomings of plastics are mechanical, e.g. chip formation and early membrane failure. Against this background, a port catheter system made of alumina ceramic, which is largely free of the disadvantages of the other materials, was developed. The expected advantages in terms of complication rate and radiological artefacts, were fully confirmed by the evaluation of 160 monitored patients.

  18. The missing foley catheter: an unusual finding in vesicouterine fistula.

    Science.gov (United States)

    Shephard, Steven N; Lengmang, Sunday J

    2013-12-18

    A 28-year-old G1P1 presented complaining of urine leakage per vaginum following caesarean delivery, accompanied by amenorrhoea, cyclic haematuria and cyclic pelvic pain. Examination findings were suggestive of vesicouterine fistula and the patient was taken for exploratory laparotomy, during which the foley catheter could not be identified within the bladder. During separation of the bladder from the uterus, the catheter was found to be traversing the fistulous tract into the uterine cavity. Vesicouterine fistula is a fairly uncommon type of urogenital fistula that is frequently associated with caesarean section. Surgical treatment remains the mainstay and successfully cured this patient. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2013.

  19. [Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].

    Science.gov (United States)

    Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J

    1989-01-01

    We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.

  20. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  1. A catheter malpositioned patient with pain and paresthesia

    Directory of Open Access Journals (Sweden)

    Akbar Fadaei Haghi

    2017-01-01

    Full Text Available We report a 54-year-old woman with the history of end-stage renal disease (ESRD who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ray showed the catheter tip was accidently pushed from right internal jugular vein into right subclavian vein during hemodialysis by the dialysis center nurse. Therefore, we believe that the physician should be aware of any changes in the catheter size after insertion. And a chest x-ray should ensure the catheter’s correct position in any patient who develops complications.

  2. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    Multiple lumen umbilical venous catheters (ML-UVCs) instead of single lumen UVCs (SL-UVCs) may decrease the need for additional venous lines. Although it seems self-evident that ML-UVCs would reduce the need of additional venous lines, the rates of associated complications might be different. To compare the effectiveness and the safety of ML-UVCs versus SL-UVCs in terms of need of additional vascular access, rates of complications, morbidity and mortality in newborn infants. Randomized and quasi-randomized trials were identified by searching the MEDLINE (1966 - February 2005), EMBASE (1980- February 2005), CINAHL (1982 - February 2005), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2004) and Science Direct (subject area: medicine, journal and abstract database; 1967 to February 2005). Literature search also included a manual search of the abstracts of scientific meetings published in Pediatric Research (1990-2004). Additional citations were sought using references in articles retrieved from searches. Subject experts were contacted to identify the unpublished and ongoing studies. Randomized and quasi-randomized controlled clinical trials comparing safety and efficacy of multiple versus single lumen umbilical venous catheter in neonates (both term and preterm) who were in need of umbilical venous catheter insertion for vascular access in first four weeks of life. Each review author performed data extraction independently and differences were resolved by discussion. The following outcomes were determined: total number of additional peripheral intravenous lines per baby in first week and first four weeks of life, total number of additional percutaneously and surgically placed central venous lines per baby in first four weeks of life, and other safety and efficacy measures. The treatment effect estimators used were RR, RD, and WMD when appropriate along with their 95% CI. If RD was statistically significant, then number

  3. Development of a Novel Shock Wave Catheter Ablation System

    Science.gov (United States)

    Yamamoto, H.; Hasebe, Yuhi; Kondo, Masateru; Fukuda, Koji; Takayama, Kazuyoshi; Shimokawa, Hiroaki

    Although radio-frequency catheter ablation (RFCA) is quite effective for the treatment tachyarrhythmias, it possesses two fundamental limitations, including limited efficacy for the treatment of ventricular tachyarrhythmias of epicardial origin and the risk of thromboembolism. Consequently, new method is required, which can eradicate arrhythmia source in deep part of cardiac muscle without heating. On the other hand, for a medical application of shock waves, extracorporeal shock wave lithotripter (ESWL) has been established [1]. It was demonstrated that the underwater shock focusing is one of most efficient method to generate a controlled high pressure in a small region [2]. In order to overcome limitations of existing methods, we aimed to develop a new catheter ablation system with underwater shock waves that can treat myocardium at arbitrary depth without causing heat.

  4. A comparison between two types of central venous catheters in the prevention of catheter-related infections: the importance of performing all the relevant cultures

    NARCIS (Netherlands)

    van Vliet, J.; Leusink, J.A.; de Jongh, B.M.; de Boer, A.

    2001-01-01

    Objective: to determine the efficacy of double-lumen central venous catheters coated with chlorhexidine and silver-sulfadiazine in reducing the incidence of catheter-related infections. Design: a randomized controlled trial. Setting: medical-surgical intensive care unit of a 600-bed teaching

  5. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  6. Cardiac pacemaker dysfunction in children after thoracic drainage catheter manipulation.

    Science.gov (United States)

    Lobdell, K W; Walters, H L; Hudson, C; Hakimi, M

    1997-05-01

    Two children underwent placement of permanent, epicardial-lead, dual-chamber, unipolar pacemaker systems for complete heart block. Postoperatively, both patients demonstrated subcutaneous emphysema-in the area of their pulse generators-temporally related to thoracic catheter manipulation. Acutely, each situation was managed with manual compression of the pulse generator, ascertaining appropriate pacemaker sensing and pacing. Maintenance of compression with pressure dressings, vigilant observation/monitoring, and education of the care givers resulted in satisfactory pacemaker function without invasive intervention.

  7. Radiologically-guided catheter drainage of intrathoracic abscesses and empyemas

    International Nuclear Information System (INIS)

    Berger, H.; Steiner, W.; Bergman, C.; Anthuber, M.; Dienemann, H.

    1993-01-01

    Radiologically guided percutaneous catheter drainage was used in 38 patients to treat pleural empyemas (35 patients) and pulmonary abscesses (3 patients). Drainage was successful in 85.7% of empyemas including 11 cases with fistulous communications. Three percutaneously drained pulmonary abscesses required subsequent lobectomy. One patient died during the drainage procedure due to sepsis. No major complications related to the drainage procedure were observed. Guided percutaneous drainage proved to be a safe and successful alternative to closed drainage of pleural fluid collections. (orig.)

  8. COST ANALYSIS OF PERIPHERALLY INSERTED CENTRAL CATHETER IN PEDIATRIC PATIENTS.

    Science.gov (United States)

    Dong, Zhaoxin; Connolly, Bairbre L; Ungar, Wendy J; Coyte, Peter C

    2018-01-01

    A peripherally inserted central catheter (PICC) is a useful option in providing secure venous access, which enables patients to be discharged earlier with the provision of home care. The objective was to identify the costs associated with having a PICC from a societal perspective, and to identify factors that are associated with total PICC costs. Data were obtained from a retrospective cohort of 469 hospitalized pediatric patients with PICCs inserted. Both direct and indirect costs were estimated from a societal perspective. Insertion costs, complication costs, nurse and physician assessment costs, inpatient ward costs, catheter removal costs, home care costs, travel costs, and the cost associated with productivity losses incurred by parents were included in this study. Based on catheter dwell time, the median total cost associated with a PICC per patient per day (including inpatient hospital costs) was $3,133.5 ($2,210.7-$9,627.0) in 2017 Canadian dollars ($1.00USD = $1.25CAD in 2017). The adjusted mean cost per patient per day was $2,648.2 ($2,402.4-$2,920.4). Excluding inpatient ward costs, the median total and adjusted costs per patient per day were $198.8 ($91.8-$2,475.8) and $362.7($341.0-$386.0), respectively. Younger age, occurrence of complications, more catheter dwell days, wards with more intensive care, and the absence of home care were significant factors associated with higher total PICC costs. This study has demonstrated the costs associated with PICCs. This information may be helpful for healthcare providers to understand PICC related cost in children and resource implications.

  9. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    Science.gov (United States)

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.

  10. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  11. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  12. [Complications associated to central venous catheters in hematology patients].

    Science.gov (United States)

    García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia

    2015-01-01

    To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  13. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  14. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  15. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  16. Development of A MEMS Based Manometric Catheter for Diagnosis of Functional Swallowing Disorders

    International Nuclear Information System (INIS)

    Hsu, H Y; Hariz, A J; Omari, T; Teng, M F; Sii, D; Chan, S; Lau, L; Tan, S; Lin, G; Haskard, M; Mulcahy, D; Bakewell, M

    2006-01-01

    Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is used in a feasibility study of developing a manometric catheter for functional swallowing disorders diagnosis. The function of a manometric catheter is to measure the peak and intrabolus pressures along the esophageal segment during the swallowing action. Previous manometric catheters used the water perfusion technique to measure the pressure changes. This type of catheter is reusable, large in size and the pressure reading is recorded by an external transducer. Current manometric catheters use a solid state pressure sensor on the catheter itself to measure the pressure changes. This type of catheter reduces the discomfort to the patient but it is reusable and is very expensive. We carried out several studies and experiments on the MEMS-based pressure sensor die, and the results show the MEMS-based pressure sensors have a good stability and a good linearity output response, together with the advantage of low excitation biasing voltage and extremely small size. The MEMS-based sensor is the best device to use in the new generation of manometric catheters. The concept of the new MEMS-based manometric catheter consists of a pressure sensing sensor, supporting ring, the catheter tube and a data connector. Laboratory testing shows that the new calibrated catheter is capable of measuring pressure in the range from 0 to 100mmHg and maintaining stable condition on the zero baseline setting when no pressure is applied. In-vivo tests are carried out to compare the new MEMS based catheter with the current version of catheters used in the hospital

  17. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  18. Pacemaker implantation after catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  19. Quantitative evaluation of catheter radiopacity by fiber optic scanning densitometry

    International Nuclear Information System (INIS)

    Solomon, D.D.; Byron, M.P.; Lipton, M.J.

    1989-01-01

    A rapid accurate method has been developed utilizing fiber optic scanning densitometry to quantify the radiopacity of vascular catheters. The technique provides for computerized calculation of relative catheter radiopacity and an appropriate control standard. A densitometer with a 180 degree collection angle for diffuse transmission density measurements was selected based on the diffusing nature of X-ray film (Q-factor 1.80). A benchmark catheter and 2 mil thick brass shim stock were selected as control standards for evaluation of mono-and multilumen tubing using standard X-ray conditions and an aluminum block attenuator. The authors present results from reproducibility studies which show scan-to-scan repeatability is within ±1%, and day-to-day variability is less than 5%. Application studies demonstrate a linear relationship between percent barium sulfate loading and the radiopaqueness of 16 gauge monolumen tubing. Results were also obtained from a clinical chest X-ray film showing good in-vivo/in-vitro correlation

  20. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    Science.gov (United States)

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P phlebitis included pain (P phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  1. Surgical Management of Multiple Valve Endocarditis Associated with Dialysis Catheter

    Directory of Open Access Journals (Sweden)

    R. Zea-Vera

    2016-01-01

    Full Text Available Endocarditis associated with dialysis catheter is a disease that must be suspected in every patient with hemodialysis who develops fever. Multiple valve disease is a severe complication of endocarditis that needs to be managed in a different way. There is very limited data for treatment and every case must be considered individually. We present a patient with this complication and describe the medical treatment and surgical management. We report the case of a 15-year-old patient with acute renal failure that develops trivalvular endocarditis after the hemodialysis catheter was placed, with multiple positive blood culture for Staphylococcus aureus. Transesophageal echocardiography was done and aortic and tricuspid valvular vegetations and mitral insufficiency were reported. Patient was successfully treated by surgery on the three valves, including aortic valve replacement. There is limited data about the appropriate treatment for multiple valvular endocarditis; it is important to consider this complication in the setting of hemodialysis patients that develop endocarditis and, despite the appropriate treatment, have a torpid evolution. In countries where endovenous drug abuse is uncommon, right sided endocarditis is commonly associated with vascular catheters. Aggressive surgical management should be the treatment of choice in these kinds of patients.

  2. A Dynamical Training and Design Simulator for Active Catheters

    Directory of Open Access Journals (Sweden)

    Georges Dumont

    2008-11-01

    Full Text Available This work addresses the design of an active multi-link micro-catheter actuated by Shape Memory Alloy (SMA micro actuators. This may be a response to one medical major demand on such devices, which will be useful for surgical explorations and interventions. In this paper, we focus on a training and design simulator dedicated to such catheters. This simulator is based on an original simulation platform (OpenMASK. The catheter is a robotic system, which is evaluated by a dynamical simulation addressing a navigation task in its environment. The design of the prototype and its mechanical model are presented. We develop an interaction model for contact. This model uses a real medical database for which distance cartography is proposed. Then we focus on an autonomous control model based on a multi-agent approach and including the behaviour description of the SMA actuators. Results of mechanical simulations including interaction with the ducts are presented. Furthermore, the interest of such a simulator is presented by applying virtual prototyping techniques for the design optimization. This optimization process is achieved by using genetic algorithms at different stages with respect to the specified task.

  3. Using central venous catheter for suprapubic catheterization in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Bilehjani E

    2017-01-01

    Full Text Available Eissa Bilehjani,1 Solmaz Fakhari2 1Department of Cardiovascular Anesthesia, Tabriz University of Medical Sciences, Madani Heart Hospital, 2Department of Anesthesiology, Tabriz University of Medical Sciences, Madani Heart Hospital, Tabriz, Iran Abstract: Suprapubic catheterization is an alternative method for urinary drainage that is used when transurethral catheterization fails. Traditionally, inserted large-bore suprapubic catheters may cause fatal complications. During the past decade, we used a small central venous catheter (CVC suprapubicly in 16 male patients for the purpose of urinary drainage, when transurethral catheterization failed. The procedure is performed in no more than 10 minutes. Success rate was 100% and this approach did not lead to any complications. In conclusion, placing a CVC for suprapubic drainage is a safe method with a high success rate and we recommend it in patients with failed transurethral catheterization after a few attempts (2–3 attempts. Keywords: suprapubic catheterization complication, urethral catheterization, central venous catheter, Seldinger’s technique, cardiac surgery

  4. A Dynamical Training and Design Simulator for Active Catheters

    Directory of Open Access Journals (Sweden)

    Georges Dumont

    2004-12-01

    Full Text Available This work addresses the design of an active multi-link micro-catheter actuated by Shape Memory Alloy (SMA micro actuators. This may be a response to one medical major demand on such devices, which will be useful for surgical explorations and interventions. In this paper, we focus on a training and design simulator dedicated to such catheters. This simulator is based on an original simulation platform (OpenMASK. The catheter is a robotic system, which is evaluated by a dynamical simulation addressing a navigation task in its environment. The design of the prototype and its mechanical model are presented. We develop an interaction model for contact. This model uses a real medical database for which distance cartography is proposed. Then we focus on an autonomous control model based on a multi-agent approach and including the behaviour description of the SMA actuators. Results of mechanical simulations including interaction with the ducts are presented. Furthermore, the interest of such a simulator is presented by applying virtual prototyping techniques for the design optimization. This optimization process is achieved by using genetic algorithms at different stages with respect to the specified task.

  5. CO laser angioplasty system: efficacy of manipulatable laser angioscope catheter

    Science.gov (United States)

    Arai, Tsunenori; Kikuchi, Makoto; Mizuno, Kyoichi; Sakurada, Masami; Miyamoto, Akira; Arakawa, Koh; Kurita, Akira; Nakamura, Haruo; Takeuchi, Kiyoshi; Utsumi, Atsushi; Akai, Yoshiro

    1992-08-01

    A percutaneous transluminal coronary angioplasty system using a unique combination of CO laser (5 micrometers ) and As-S infrared glass fiber under the guidance of a manipulatable laser angioscope catheter is described. The ablation and guidance functions of this system are evaluated. The angioplasty treatment procedure under angioscope guidance was studied by in vitro model experiment and in vivo animal experiment. The whole angioplasty system is newly developed. That is, a transportable compact medical CO laser device which can emit up to 10 W, a 5 F manipulatable laser angioscope catheter, a thin CO laser cable of which the diameter is 0.6 mm, an angioscope imaging system for laser ablation guidance, and a system controller were developed. Anesthetized adult mongrel dogs (n equals 5) with an artificial complete occlusion in the femoral artery and an artificial human vessel model including occluded or stenotic coronary artery were used. The manipulatability of the catheter was drastically improved (both rotation and bending), therefore, precise control of ablation to expand stenosis was obtained. A 90% artificial stenosis made of human yellow plaque in 4.0 mm diameter in the vessel was expanded to 70% stenosis by repetitive CO laser ablations of which total energy was 220 J. All procedures were performed and controlled under angioscope visualization.

  6. Central venous catheter-related bloodstream infections in cancer patients

    International Nuclear Information System (INIS)

    Butt, T.; Afzal, R.K.; Ahmad, R.N.; Hussain, I.; Anwar, M.

    2004-01-01

    Objective: To determine the frequency of central venous catheter-related bloodstream infections (CR-BSI) in cancer patients and the antimicrobial susceptibility pattern of the isolates. Subjects and Methods: Cancer patients requiring short or long-term central venous catheterization at the time of admission or thereafter were included. Catheter tips on removal were cultured quantitatively; specimens of blood and pus were cultured qualitatively. Isolates were identified and antimicrobial susceptibility testing was performed by standard techniques. Results: Eighty-nine patients were included in the study. The frequency of CR-BSI was 17%. Out of the 19 organisms isolated, 10 (53%) were Gram-positive cocci, 8 (42%) were Gram-negative rods and 1 (5%) was a fungus. Coagulase negative staphylococci (27%) were the predominant pathogens. Among the staphylococci, 46% of the isolates were methicillin-resistant. All Gram-positive isolates were susceptive to glycopeptides. Gram-negative rods were resistant to most of the commonly used antimicrobial groups. Conclusion: Central venous catheter is an important source of bloodstream infections in cancer patients. Most of the infections are caused by Gram-positive cocci. Rigorous infection control measures and continuous surveillance is required to curb the frequency of these infections. (author)

  7. Immediate Catheter Directed Thrombolysis for Thromboembolic Stroke During Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    E. Fletcher

    Full Text Available : Background: Carotid artery endarterectomy (CEA is a common procedure undertaken by vascular surgeons with over 5,000 procedures performed annually worldwide. Published rates of perioperative stroke range from 1.3% to 6.3%. Case report: A case is presented in which on-table intra-cranial angiography and catheter directed thrombolysis were used for a thromboembolic occlusion of the distal internal carotid artery (ICA and proximal middle cerebral artery (MCA. An 83-year-old lady developed a dense right hemiparesis while undergoing a CEA under local anaesthetic (LA. Immediate re-exploration of the endarterectomy did not reveal technical error. Intraoperative duplex scanning of the internal carotid artery revealed no detectable diastolic flow. On-table angiogram showed complete occlusion of the distal ICA and proximal MCA. Catheter directed administration of TPA was undertaken. The entire ICA and MCA were completely clear on a completion angiogram. The patient made a full neurological recovery. Discussion and conclusion: Prompt diagnosis and treatment with intraoperative catheter directed thrombolysis can resolve thromboembolic occlusion of the ICA/MCA. It is argued that performing CEA under LA is useful for immediate recognition of perioperative stroke. Furthermore, the advantage is highlighted of vascular surgeons having both the resources and skillset to perform on-table angiography and thrombolysis. Keywords: Carotid endarterectomy, Stroke, Thrombolysis, Thromboembolus, Local anaesthetic

  8. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate......We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...

  9. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  10. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  11. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  12. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978

  13. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  14. Using an indwelling catheter for the domiciliary management of malignant effusions

    Directory of Open Access Journals (Sweden)

    Ramkumar P

    2003-01-01

    Full Text Available Background: Many patients with malignant pleural effusions and ascites require repeated hospital visits for paracentesis. Materials and Methods: Patients and caregivers were taught to drain malignant effusions at home, using an indwelling catheter inserted into the pleural/ peritoneal cavity. The catheter, (ARROW 14 wire gauge with three additional side holes made to prevent blockage was inserted using the Seldenger technique for central venous cannulation and secured with a stitch. A three way stopcock was used to regulate fluid drainage. The caregiver was taught to do biweekly dressings with antiseptic ointment. Results: The catheter has been used in 200 patients over a period of five years. Two patients developed infections in the pleural cavity, which were managed with antibiotics. Two patients needed catheter change because of blockage. Other patients retained the catheter till last follow up or death. The procedure can be carried out as a day case. This article describes practical guidelines for inserting and maintaining the catheter.

  15. A simple method of using a Foley catheter to drain pleural effusion.

    Science.gov (United States)

    Ben-Nun, Alon; Best, Lael Anson

    2008-01-01

    Pleural effusion is a common problem, and various techniques of pleural fluid drainage have been described. We report our experience of using a Foley-type catheter to drain pleural effusion. After the injection of local anesthesia, the catheter is inserted, usually through the 7th intercostal space, with the patient sitting upright. The size of the catheter is selected according to the predicted fluid characteristics, and ranges from 18 to 24 F. Once the catheter is positioned in the pleural space, the balloon is inflated with diluted soluble contrast material and connected to a urine collection bag. During the last 10 years, we have used 3500 catheters for this purpose. The catheter site can be used as a port for various procedures, including needle biopsy of the parietal pleura, talc-slurry pleurodesis, and intra-pleural fibrinolysis. This method of pleural drainage is simple, reliable, and inexpensive.

  16. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  17. Missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

    Directory of Open Access Journals (Sweden)

    Biswajit Majumder

    2016-01-01

    Full Text Available Coronary angiography by right radial artery route using Optitorque Tiger catheter is on the rise given the low rate of local complications and feasibility to perform it as a day-care procedure. We report here a case of coronary angiography performed using Optitorque Tiger catheter (5-French which resulted in a diagnostic error, missing the ostio-proximal left main coronary artery disease which was later detected using EBU 3.5 guide catheter (7-French while performing angioplasty.

  18. Ultrasound-guided Placement of a Foley Catheter Using a Hydrophilic Guide Wire

    Directory of Open Access Journals (Sweden)

    Mark Huber

    2018-03-01

    Full Text Available Acute urinary retention is a common problem in the emergency department. Patients can present in significant distress, necessitating the placement of a urinary catheter. Foley catheter placement can be difficult to accomplish depending on the etiology of the retention and the degree of the obstruction. In the case presented here, we used ultrasound guidance, a guidewire, and a Foley catheter to successfully relieve a patient’s urinary retention after multiple failed attempts.

  19. Catheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis

    Directory of Open Access Journals (Sweden)

    Noriko Hattori

    2012-01-01

    Full Text Available Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter insertion—namely, catheter displacement into the inferior epigastric vein.

  20. A unique case of pulmonary artery catheter bleeding from the oximetry connection port

    Directory of Open Access Journals (Sweden)

    Suman Rajagopalan

    2014-12-01

    Full Text Available Pulmonary artery catheter is an invasive monitor usually placed in high-risk cardiac surgical patients to optimize the cardiac functions. We present this case of blood oozing from the oximetry connection port of the pulmonary artery catheter that resulted in the inability to monitor continuous cardiac output requiring replacement of the catheter. The cause of this abnormal bleeding was later confirmed to be due to a manufacturing defect.