WorldWideScience

Sample records for instruments major section

  1. SSCL RFQ-DTL Matching Section instrumentation

    International Nuclear Information System (INIS)

    Datte, P.; Aielo, R.; Hayworth, M.

    1993-11-01

    A description of the SSCL RFQ-DTL Matching Section instrumentation is presented with emphasis on design issues and early instrumentation commissioning results. The H - beam energy through the RFQ-DTL matching section is 2.5 MeV, the beam current is 27 mA with a pulse width of 35 Its. The typical beam diameter is 3 mm. The instrumentation consists of three beam position monitors (BPM), a wire scanner, beam loss monitors (BLM), a slit and collector emittance measurement unit (EMU), a current toroid, and a Faraday cup. The instruments were designed to accommodate high current densities, have a large dynamic range with moderate bandwidths, and fit congested spaces

  2. Instrument ampersand controls section (IA) improvements

    International Nuclear Information System (INIS)

    Kramer, C.; Paul, J.

    1993-01-01

    This portion of the panel session briefly delineates improvements in the Instrument and Controls (IA) Section over the past few years. These improvements are listed briefly in summary form. The status of publication of the IA Section of AG-1 is reviewed

  3. 26 CFR 1.1274-1 - Debt instruments to which section 1274 applies.

    Science.gov (United States)

    2010-04-01

    ... includes debt instruments and investment units, but does not include money, services, or the right to use... nonfunctional currency is treated as money rather than as property. (b) Exceptions—(1) Debt instrument with....1273-2. (3) Other exceptions to section 1274—(i) Holders of certain below-market instruments. Section...

  4. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  5. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  6. 28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...

  7. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.

    Science.gov (United States)

    Kim, H C; Kim, H J; Lee, C J; Kim, B M; Park, J K; Versluis, A

    2009-07-01

    To evaluate how different cross-sectional designs affect stress distribution in nickel-titanium (NiTi) instruments during bending, torsion and simulated shaping of a curved canal. Four NiTi rotary instruments with different cross-sectional geometries were selected: ProFile and HeroShaper systems with a common triangle-based cross section, Mtwo with an S-shaped rectangle-based design and NRT with a modified rectangle-based design. The geometries of the selected files were scanned in a micro-CT and three-dimensional finite-element models were created for each system. Stiffness characteristics for each file system were determined in a series of bending and torsional conditions. Canal shaping was simulated by inserting models of the rotating file into a 45 degrees curved canal model. Stress distribution in the instruments was recorded during simulated shaping. After the instruments were retracted from the canal, residual stresses and permanent bending of their tips due to plastic deformation were determined. The greatest bending and torsional stiffness occurred in the NRT file. During simulated shaping, the instruments with triangle-based cross-sectional geometry had more even stress distributions along their length and had lower stress concentrations than the instruments with rectangle-based cross sections. Higher residual stresses and plastic deformations were found in the Mtwo and NRT with rectangle-based cross-sectional geometries. Nickel-titanium instruments with rectangle-based cross-sectional designs created higher stress differentials during simulated canal shaping and may encounter higher residual stress and plastic deformation than instruments with triangle-based cross sections.

  8. Risk factors for cesarean section and instrumental vaginal delivery after successful external cephalic version.

    Science.gov (United States)

    de Hundt, Marcella; Vlemmix, Floortje; Bais, Joke M J; de Groot, Christianne J; Mol, Ben Willem; Kok, Marjolein

    2016-01-01

    Aim of this article is to examine if we could identify factors that predict cesarean section and instrumental vaginal delivery in women who had a successful external cephalic version. We used data from a previous randomized trial among 25 hospitals and their referring midwife practices in the Netherlands. With the data of this trial, we performed a cohort study among women attempting vaginal delivery after successful ECV. We evaluated whether maternal age, gestational age, parity, time interval between ECV and delivery, birth weight, neonatal gender, and induction of labor were predictive for a vaginal delivery on one hand or a CS or instrumental vaginal delivery on the other hand. Unadjusted and adjusted odds ratios were calculated with univariate and multivariate logistic regression analysis. Among 301 women who attempted vaginal delivery after a successful external cephalic version attempt, the cesarean section rate was 13% and the instrumental vaginal delivery rate 6%, resulting in a combined instrumental delivery rate of 19%. Nulliparity increased the risk of cesarean section (OR 2.7 (95% CI 1.2-6.1)) and instrumental delivery (OR 4.2 (95% CI 2.1-8.6)). Maternal age, gestational age at delivery, time interval between external cephalic version and delivery, birth weight and neonatal gender did not contribute to the prediction of failed spontaneous vaginal delivery. In our cohort of 301 women with a successful external cephalic version, nulliparity was the only one of seven factors that predicted the risk for cesarean section and instrumental vaginal delivery.

  9. Regulatory instrument review: Management of aging of LWR [light water reactor] major safety-related components

    International Nuclear Information System (INIS)

    Werry, E.V.

    1990-10-01

    This report comprises Volume 1 of a review of US nuclear plant regulatory instruments to determine the amount and kind of information they contain on managing the aging of safety-related components in US nuclear power plants. The review was conducted for the US Nuclear Regulatory Commission (NRC) by the Pacific Northwest Laboratory (PNL) under the NRC Nuclear Plant Aging Research (NPAR) Program. Eight selected regulatory instruments, e.g., NRC Regulatory Guides and the Code of Federal Regulations, were reviewed for safety-related information on five selected components: reactor pressure vessels, steam generators, primary piping, pressurizers, and emergency diesel generators. Volume 2 will be concluded in FY 1991 and will also cover selected major safety-related components, e.g., pumps, valves and cables. The focus of the review was on 26 NPAR-defined safety-related aging issues, including examination, inspection, and maintenance and repair; excessive/harsh testing; and irradiation embrittlement. The major conclusion of the review is that safety-related regulatory instruments do provide implicit guidance for aging management, but include little explicit guidance. The major recommendation is that the instruments be revised or augmented to explicitly address the management of aging

  10. A Comparison of the Basic Song Repertoire of Vocal/Choral and Instrumental Music Education Majors.

    Science.gov (United States)

    Prickett, Carol A.; Bridges, Madeline S.

    2000-01-01

    Explores whether the basic song repertoire of vocal/choral music education majors is significantly better than instrumental music education majors. Participants attempted to identify 25 standard songs. Reveals no significant difference between the two groups, indicating that neither had developed a strong repertoire of songs. (CMK)

  11. An Observational Study of Score Study Practices among Undergraduate Instrumental Music Education Majors

    Science.gov (United States)

    Silvey, Brian A.; Montemayor, Mark; Baumgartner, Christopher M.

    2017-01-01

    The purpose of this study was to investigate undergraduate instrumental music education majors' score study practices as they related to the effectiveness of their simulated conducting. Participants (N = 30) were video recorded in two sessions in which they completed a 20-min score study session and a simulated conducting performance. In the first…

  12. Cannula has lip seal movingly coupled to proximal section, to facilitate relative movement of instrument shaft between seal and proximal section and to maintain sealing engagement between shaft and proximal portion

    OpenAIRE

    Bonadio, Frank; Vaugh, Trevor

    2007-01-01

    The cannula (1) has an instrument insertion section (3) and a tube (2) with an access channel (7) for extension of an instrument. A lip seal (4) movingly couples to a proximal section to engage with an instrument shaft (5). The seal facilitates a lateral movement of the instrument, and maintains the sealing engagement between the seal and the instrument shaft. A coupling portion made of gelatinous elastomeric material with plasticizer consisting of naturally derived oils, synthetic oils and l...

  13. Caesarean Section at Full Dilatation and Risk of Major Obstetric Haemorrhage

    LENUS (Irish Health Repository)

    O’Dwyer, V

    2018-03-01

    The purpose of the study was to examine the risk factors for caesarean section (CS) at full dilatation and to assess the risk and management of haemorrhage. The study took place in a tertiary referral maternity hospital. Women who had a CS at full dilatation were included. Clinical and demographic details were recorded. There were 199 cases. The average age was 30.3 years and average BMI was 25.8kg\\/m2. There were 79.9 % (159) primigravidas and 20.1% (40) multigravidas. The average gestation at delivery was 39.4 weeks. Labour was induced in 46.9 % (92) and spontaneous in 53.8% (107). Oxytocin was used in 67.8 % (135). An instrumental delivery was attempted in 46.7 % (93). The rate of malposition was 46.5 % (92). The average birthweight was 3,629g and 9 babies weighed ≥4.5kg. The average estimated blood loss (EBL) was 665mls and 34 had EBL>1L. Most had an oxytocin infusion (141). Other uterotonic agents were used in 70 women. Seven women had blood transfusions. The highest rate of CS at full dilatation was in primigravidas due to malposition. There was a low rate of major obstetric haemorrhage.

  14. Neutron cross section standards and instrumentation. Annual report

    Energy Technology Data Exchange (ETDEWEB)

    Wasson, O.A.

    1993-07-01

    The objective of this interagency program is to provide accurate neutron interaction measurements for the US Department of Energy nuclear programs which include waste disposal, fusion, safeguards, defense, fission, and personnel protection. These measurements are also useful to other energy programs which indirectly use the unique properties of the neutron for diagnostic and analytical purposes. The work includes the measurement of reference cross sections and related neutron data employing unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; the preservation of standard reference deposits and the development of improved neutron detectors and measurement methods. A related and essential element of the program is critical evaluation of neutron interaction data including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology. This report from the National Institute of Standards and Technology contains a summary of the accomplishments of the Neutron Cross Section Standards and Instrumentation Project during the third year of this three-year interagency agreement. The proposed program and required budget for the following three years are also presented. The program continues the shifts in priority instituted in order to broaden the program base.

  15. Neutron cross section standards and instrumentation. Annual report

    International Nuclear Information System (INIS)

    Wasson, O.A.

    1993-01-01

    The objective of this interagency program is to provide accurate neutron interaction measurements for the US Department of Energy nuclear programs which include waste disposal, fusion, safeguards, defense, fission, and personnel protection. These measurements are also useful to other energy programs which indirectly use the unique properties of the neutron for diagnostic and analytical purposes. The work includes the measurement of reference cross sections and related neutron data employing unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; the preservation of standard reference deposits and the development of improved neutron detectors and measurement methods. A related and essential element of the program is critical evaluation of neutron interaction data including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology. This report from the National Institute of Standards and Technology contains a summary of the accomplishments of the Neutron Cross Section Standards and Instrumentation Project during the third year of this three-year interagency agreement. The proposed program and required budget for the following three years are also presented. The program continues the shifts in priority instituted in order to broaden the program base

  16. The Science Teaching Self-Efficacy of Prospective Elementary Education Majors Enrolled in Introductory Geology Lab Sections

    Science.gov (United States)

    Baldwin, Kathryn A.

    2014-01-01

    This study examined prospective elementary education majors' science teaching self-efficacy while they were enrolled in an introductory geology lab course for elementary education majors. The Science Teaching Efficacy Belief Instrument Form B (STEBI-B) was administered during the first and last lab class sessions. Additionally, students were…

  17. Neutron cross section standards and instrumentation: Annual report

    International Nuclear Information System (INIS)

    1987-01-01

    This annual report from the National Bureau of Standards contains a summary of the results of the Neutron Cross Section Standards and Instrumentation Program. The technical measurements for the past year are given along with the proposed program and budget needs for the next three years. The neutron standards measurements have concentrated on the most important 235 U(n,f) cross section in the thermal to 20 MeV energy range along with the development of neutron detectors required for these measurements. The NBS measurements have made a significant contribution to the improvement in the understanding of this reaction. Measurements were performed with numerous neutron detectors at overlapping energies and at different neutron sources in order to reduce the systematic errors to achieve the required accuracy in this important neutron standard. Significant progress was also made in the development of a detector to utilize the 3 He(n,p) reaction as a standard in the eV to MeV energy region. Improvements in data acquisition systems as well as additional studies of advanced neutron sources were accomplished. Contacts with private industry were maintained and coordination of the neutron standards evaluation was continued. The report also includes biographical listings of the research staff along with copies of a few of our recent publications. 13 figs., 1 tab

  18. Risk factors for cesarean section and instrumental vaginal delivery after successful external cephalic version

    NARCIS (Netherlands)

    de Hundt, Marcella; Vlemmix, Floortje; Bais, Joke M. J.; de Groot, Christianne J.; Mol, Ben Willem; Kok, Marjolein

    2016-01-01

    Aim of this article is to examine if we could identify factors that predict cesarean section and instrumental vaginal delivery in women who had a successful external cephalic version. We used data from a previous randomized trial among 25 hospitals and their referring midwife practices in the

  19. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  20. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  1. Creation and validation of the self-efficacy instrument for physical education teacher education majors toward inclusion.

    Science.gov (United States)

    Block, Martin E; Hutzler, Yeshayahu; Barak, Sharon; Klavina, Aija

    2013-04-01

    The purpose was to validate a self-efficacy (SE) instrument toward including students with disability in physical education (PE). Three scales referring to intellectual disabilities (ID), physical disabilities (PD), or visual impairments (VI) were administered to 486 physical education teacher education (PETE) majors. The sample was randomly split, and exploratory and confirmatory factor analyses (EFA and CFA, respectively) were conducted. After deleting items that did not meet inclusion criteria, EFA item loadings ranged from 0.53 to 0.91, and Cronbach's alpha reliability was high (for ID = .86, PD = .90, and VI = .92). CFA showed that the ID scale demonstrated good goodness-of-fit, whereas in the PD and in the VI scales demonstrated moderate fit. Thus, the content and construct validity of the instrument was supported.

  2. Assessment and management of ageing of major nuclear power plant components important to safety: In-containment instrumentation and control cables. Volume I

    International Nuclear Information System (INIS)

    2000-12-01

    and technical support organizations dealing with specific plant components addressed in the reports. The component addressed in the present report is the in-containment instrumentation and control (I and C) cables. The report presents, in two volumes, results of a Co-ordinated Research Project (CRP) on the Management of Ageing of In-containment Instrumentation and Control cables. Part I, Volume 1 presents information on current methods for assessing and managing ageing degradation of Instrumentation and Control cables in real NPP environments prepared by the CRP team. An important complement of this information is user perspectives on the application of these methods which are presented in Part II, Volume 1. Volume 2 contains annexes supporting the guidance of Volume 1 with more detailed information and examples provided by individual CRP participants. For a quick overview, readers should see Section 8 of Part I, Volume 1, which describes a systematic ageing management programme for Instrumentation and Control cables utilizing methods presented in the report; Section 9 of Part I, Volume 1, which presents CRP conclusions and recommendations; and Part II providing the application guidance from the user's perspective

  3. Assessment and management of ageing of major nuclear power plant components important to safety: In-containment instrumentation and control cables. Volume II

    International Nuclear Information System (INIS)

    2000-12-01

    and technical support organizations dealing with specific plant components addressed in the reports. The component addressed in the present report is the in-containment instrumentation and control (I and C) cables. The report presents, in two volumes, results of a Co-ordinated Research Project (CRP) on the Management of Ageing of In-containment Instrumentation and Control cables. Part I, Volume 1 presents information on current methods for assessing and managing ageing degradation of Instrumentation and Control cables in real NPP environments prepared by the CRP team. An important complement of this information is user perspectives on the application of these methods which are presented in Part II, Volume 1. Volume 2 contains annexes supporting the guidance of Volume 1 with more detailed information and examples provided by individual CRP participants. For a quick overview, readers should see Section 8 of Part I, Volume 1, which describes a systematic ageing management programme for Instrumentation and Control cables utilizing methods presented in the report; Section 9 of Part I, Volume 1, which presents CRP conclusions and recommendations; and Part II providing the application guidance from the user's perspective

  4. Hematogenous candida pneumonia in major burn patients: plain chest radiograph and thin-section CT findings

    International Nuclear Information System (INIS)

    Kim, Hyo Heon; Lee, Eil Seong; Shim, Ya Seong; Kim, Ji Hun; Suh, Hong Kil; Cho, Sin Young; Kim, Dae Sun; Lee, Kil Woo; Kang, Ik Won

    1995-01-01

    To describe plain radiographic and thin-section CT findings of hematogenous candida pneumonia in major burn patients. We reviewed nine cases of hematogenous candida pneumonia in major burn patients who had positive blood culture for candida and findings of pneumonia on plain chest radiograph. On five of nine cases, thin-section CT was done. We evaluated retrospectively nine cases for onset, the pattern, distribution, and size of lesions on plain chest radiograph and thin-section CT. On plain chest radiograph, randomly distributed 2-10 mm nodules were seen in six cases(66%) and randomly distributed 10-15 mm consolidations in remaining three cases(33%). Lesion occurred in 11th to 75th post-burn day(average, 34th post-burn day). Other findings were cardiomegaly in three cases, atelectasis in three cases, and pulmonary edema in one case. Thin-section CT showed variable shaped subpleural nodules in all five cases. The size of nodules were 1-5 mm in two cases(40%) and 5-10 mm(60%) in three cases. Feeding vessel signs were seen in two cases. Other findings were atelectasis in three cases, cardiomegaly in three cases, ground-glass opacity and interlobular septal thickenings by pulmonary edema in two cases. Plain chest radiographic findings of hematogenous candida pneumonia in major burn patients are randomly distributed nodules or consolidations of variable size. Thin-section CT findings are variable shaped subpleural nodules less than 1 cm

  5. Measuring post-secondary stem majors' engagement in sustainability: The creation, assessment, and validation of an instrument for sustainability curricula evaluation

    Science.gov (United States)

    Little, David L., II

    Ongoing changes in values, pedagogy, and curriculum concerning sustainability education necessitate that strong curricular elements are identified in sustainability education. However, quantitative research in sustainability education is largely undeveloped or relies on outdated instruments. In part, this is because no widespread quantitative instrument for measuring related educational outcomes has been developed for the field, though their development is pivotal for future efforts in sustainability education related to STEM majors. This research study details the creation, evaluation, and validation of an instrument -- the STEM Sustainability Engagement Instrument (STEMSEI) -- designed to measure sustainability engagement in post-secondary STEM majors. The study was conducted in three phases, using qualitative methods in phase 1, a concurrent mixed methods design in phase 2, and a sequential mixed methods design in phase 3. The STEMSEI was able to successfully predict statistically significant differences in the sample (n= 1017) that were predicted by prior research in environmental education. The STEMSEI also revealed statistically significant differences between STEM majors' sustainability engagement with a large effect size (.203 ≤ eta2 ≤ .211). As hypothesized, statistically significant differences were found on the environmental scales across gender and present religion. With respect to gender, self-perceived measures of emotional engagement with environmental sustainability was higher with females while males had higher measures in cognitive engagement with respect to knowing information related to environmental sustainability. With respect to present religion, self-perceived measures of general engagement and emotional engagement in environmental sustainability were higher for non-Christians as compared to Christians. On the economic scales, statistically significant differences were found across gender. Specifically, measures of males' self

  6. SMAP Instrument Mechanical System Engineering

    Science.gov (United States)

    Slimko, Eric; French, Richard; Riggs, Benjamin

    2013-01-01

    The Soil Moisture Active Passive (SMAP) mission, scheduled for launch by the end of 2014, is being developed to measure the soil moisture and soil freeze/thaw state on a global scale over a three-year period. The accuracy, resolution, and global coverage of SMAP measurements are invaluable across many science and applications disciplines including hydrology, climate, carbon cycle, and the meteorological, environment, and ecology applications communities. The SMAP observatory is composed of a despun bus and a spinning instrument platform that includes both a deployable 6 meter aperture low structural frequency Astromesh reflector and a spin control system. The instrument section has engendered challenging mechanical system issues associated with the antenna deployment, flexible antenna pointing in the context of a multitude of disturbances, spun section mass properties, spin control system development, and overall integration with the flight system on both mechanical and control system levels. Moreover, the multitude of organizations involved, including two major vendors providing the spin subsystem and reflector boom assembly plus the flight system mechanical and guidance, navigation, and control teams, has led to several unique system engineering challenges. Capturing the key physics associated with the function of the flight system has been challenging due to the many different domains that are applicable. Key interfaces and operational concepts have led to complex negotiations because of the large number of organizations that integrate with the instrument mechanical system. Additionally, the verification and validation concerns associated with the mechanical system have had required far-reaching involvement from both the flight system and other subsystems. The SMAP instrument mechanical systems engineering issues and their solutions are described in this paper.

  7. A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue.

    Science.gov (United States)

    Oh, So-Ram; Chang, Seok-Woo; Lee, Yoon; Gu, Yu; Son, Won-Jun; Lee, Woocheol; Baek, Seung-Ho; Bae, Kwang-Shik; Choi, Gi-Woon; Lim, Sang-Min; Kum, Kee-Yeon

    2010-04-01

    This study examined the effect of the manufacturing methods (ground, electropolished, and twisted) and the cross-sectional area (CSA) of nickel-titanium (NiTi) rotary instruments on their cyclic fatigue resistance. A total of 80 NiTi rotary instruments (ISO 25/.06 taper) from 4 brands (K3, ProFile, RaCe, and TF) were rotated in a simulated root canal with pecking motion until fracture. The number of cycles to failure (NCF) was calculated. The CSA at 3 mm from the tip of new instruments of each brand was calculated. The correlation between the CSA and NCF was evaluated. All fractured surfaces were analyzed using a scanning electron microscope to determine the fracture mode. The TF instruments were the most resistant to fatigue failure. The resistance to cyclic failure increased with decreasing CSA. All fractured surfaces showed the coexistence of ductile and brittle properties. The CSA had a significant effect on the fatigue resistance of NiTi rotary instruments. Copyright 2010 Mosby, Inc. All rights reserved.

  8. A performance improvement program applied to the Perry Nuclear Power Plant instrumentation and control section

    International Nuclear Information System (INIS)

    Anderson, G.R.

    1987-01-01

    The management at Cleveland Electric Illuminating Company sought to avoid problems typically encountered in the start-up of new nuclear generating units. In response to early indications that such problems may have been developing at their Perry Nuclear Power Plant, several performance improvement initiatives were undertaken. One of these initiatives was a performance improvement evaluation (PIE) for the instrumentation and control (IandC) section at Perry. The IandC PIE, which used a method designed to be adaptable to other disciplines as well, had important results that are applicable to other nuclear power plants

  9. Technical Support Section Instrument Support Program for nuclear and nonnuclear facilities with safety requirements

    International Nuclear Information System (INIS)

    Adkisson, B.P.; Allison, K.L.

    1995-01-01

    This document describes requirements, procedures, and supervisory responsibilities of the Oak Ridge National Laboratory (ORNL) Instrumentation and Controls (I ampersand C) Division's Technical Support Section (TSS) for instrument surveillance and maintenance in nonreactor nuclear facilities having identified Operational Safety Requirements (OSRs) or Limiting Conditions Document (LCDs). Implementation of requirements comply with the requirements of U.S. Department of Energy (DOE) Orders 5480.5, 5480.22, and 5481.1B; Martin Marietta Energy Systems, Inc. (Energy Systems), Policy Procedure ESS-FS-201; and ORNL SPP X-ESH-15. OSRs and LCDs constitute an agreement or contract between DOE and the facility operating management regarding the safe operation of the facility. One basic difference between OSRs and LCDs is that violation of an OSR is considered a Category II occurrence, whereas violation of an LCD requirement is considered a Category III occurrence (see Energy Systems Standard ESS-OP-301 and ORNL SPP X-GP-13). OSRs are required for high- and moderate-hazard nuclear facilities, whereas the less-rigorous LCDs are required for low-hazard nuclear facilities and selected open-quotes generally acceptedclose quotes operations. Hazard classifications are determined through a hazard screening process, which each division conducts for its facilities

  10. Organizational justice and major depressive episodes in Japanese employees: a cross-sectional study.

    Science.gov (United States)

    Inoue, Akiomi; Kawakami, Norito; Tsuno, Kanami; Tomioka, Kimiko; Nakanishi, Mayuko

    2013-01-01

    Several European studies showed that low organizational justice (i.e., procedural justice and interactional justice) was associated with major depressive disorders. In these studies, however, the diagnosis of major depressive disorders may be underestimated because they identified only individuals who visited a doctor and received a diagnosis. Moreover, these studies did not consider neurotic personality traits, which can affect the occurrence of major depressive disorders. The purpose of the present study was to investigate the cross-sectional association of organizational justice with major depressive episodes in the past 12 months more precisely in Japanese employees. A total of 425 males and 708 females from five branches of a manufacturing company in Japan completed self-administered questionnaires measuring organizational justice, other job stressors (i.e., job strain, social support at work, and effort-reward imbalance), neuroticism, and demographic characteristics. A web-based self-administered version of the computerized Composite International Diagnostic Interview Version 3.0 (CIDI 3.0) was used to assess major depressive episodes. Logistic regression analyses were conducted. In the univariate analysis, low procedural justice and low interactional justice were significantly associated with major depressive episodes in the past 12 months. After adjusting for other job stressors and demographic characteristics, only the association of interactional justice remained significant. The moderating effect of neuroticism on the association of organizational justice with major depressive episodes in the past 12 months was not significant. Low interactional justice may be associated with major depressive disorders regardless or other job stressors or neurotic personality traits.

  11. On the structural logic of curriculum system for the optical instrument major

    Science.gov (United States)

    Yan, Yufeng; Yan, Juncen; Li, Yang; Shi, Lixia

    2017-08-01

    The theories of optical instrument are the Interdisciplinary of Optical Engineering and Instrument Science and Technology. The undergraduates should study the knowledge about the optics, precision machine and electronics. The courses such as Theory of Machine, Engineering Optics, even include some courses about Accuracy Analysis of Instrument are offered in the college. There are a lot of correlatives among these courses. This paper focuses on the structural logic of these courses. The order of these courses is researched, The aims of all the courses are clear completely to avoid the same topics to be taught twice in different courses. Therefore, the undergraduates would get the main line of the knowledge, and the professors would teach efficiently.

  12. A comparison of instrumentation using Naviflex and Profile nickel-titanium engine-driven rotary instruments.

    Science.gov (United States)

    Ottosen, S R; Nicholls, J I; Steiner, J C

    1999-06-01

    This study was designed to compare the changes in canal configuration resulting from instrumentation by either Profile or Naviflex instruments. Forty mesial canals in extracted human molar teeth were embedded and sectioned at two root levels. Reassembled teeth were instrumented with a modified crown-down technique as described in the Profile training video for Profile files and in a similar manner for Naviflex instruments. Superimposed pre- and postinstrumented cross-sectional root images were projected, traced, and scanned into a computer for analysis. Canal movement, in relation to the furca, and canal area change were recorded. The results showed no significant difference in canal center movement or canal area change between the Profile or Naviflex groups. The degree of canal curvature had no effect on canal center movement or canal area change.

  13. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  14. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  15. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  16. ACRF Instrumentation Status and Information September 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  17. ACRF Instrumentation Status and Information April 2009

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2009-05-07

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  18. ACRF Instrumentation Status and Information August 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-09-09

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  19. ACRF Instrumentation Status and Information July 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-08-13

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  20. ACRF Instrumentation Status and Information - June 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-06-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  1. ACRF Instrumentation Status and Information May 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  2. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  3. The quality of informed consent in Croatia-a cross-sectional study and instrument development.

    Science.gov (United States)

    Vučemilo, Luka; Milošević, Milan; Dodig, Doris; Grabušić, Bruno; Đapić, Biljana; Borovečki, Ana

    2016-03-01

    To examine the informed consent process implementation and quality in Croatia using a specially developed instrument. A cross-sectional questionnaire study was conducted in 300 patients (response rate 73%) from six hospitals in Croatia, along with psychometric evaluation of the questionnaire. Signing the informed consent form was a formality for 64% of patients, 54% of patients did not give their written consent, and in 39% of cases physicians made treatment decisions by themselves. The overall informed consent process score was 4.06±0.60 (of 5.00). Physician-patient relationship score was 4.61±0.57, Verbal information 3.99±0.98, Decision making 3.94±0.75, and Written information 3.60±1.42. The overall Cronbach's alpha coefficient was 0.890. Significant correlations were found in relation to Physician-patient relationship and education levels (OR=0.43, 95% CI=0.18-0.99, p=0.048), and Verbal information and duration of health problems (OR=1.83, 95% CI=1.02-3.25, p=0.041). The developed questionnaire is reliable and valid. The informed consent process quality in Croatia was reasonably high, although insufficient and inadequate written materials represent a weak spot that require enhancement. The study contributes to the development of suitable measuring instrument for assessment of the informed consent process quality in clinical practice. The questionnaire could be of use in the hospital accreditation process. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. 21 CFR 872.4565 - Dental hand instrument.

    Science.gov (United States)

    2010-04-01

    ... chisel, endodontic broach, dental wax carver, endodontic pulp canal file, hand instrument for calculus... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A...

  5. Diagnostic performance of major depression disorder case-finding instruments used among mothers of young children in the United States: A systematic review.

    Science.gov (United States)

    Owora, Arthur H; Carabin, Hélène; Reese, Jessica; Garwe, Tabitha

    2016-09-01

    Growing recognition of the interrelated negative outcomes associated with major depression disorder (MDD) among mothers and their children has led to renewed public health interest in the early identification and treatment of maternal MDD. Healthcare providers, however, remain unsure of the validity of existing case-finding instruments. We conducted a systematic review to identify the most valid maternal MDD case-finding instrument used in the United States. We identified articles reporting the sensitivity and specificity of MDD case-finding instruments based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) by systematically searching through three electronic bibliographic databases, PubMed, PsycINFO, and EMBASE, from 1994 to 2014. Study eligibility and quality were evaluated using the Standards for the Reporting of Diagnostic Accuracy studies and Quality Assessment of Diagnostic Accuracy Studies guidelines respectively. Overall, we retrieved 996 unduplicated articles and selected 74 for full-text review. Of these, 14 articles examining 21 different instruments were included in the systematic review. The 10 item Edinburgh Postnatal Depression Scale and Postpartum Depression Screening Scale had the most stable (lowest variation) and highest diagnostic performance during the antepartum and postpartum periods (sensitivity range: 0.63-0.94 and 0.67-0.95; specificity range: 0.83-0.98 and 0.68-0.97 respectively). Greater variation in diagnostic performance was observed among studies with higher MDD prevalence. Factors that explain greater variation in instrument diagnostic performance in study populations with higher MDD prevalence were not examined. Findings suggest that the diagnostic performance of maternal MDD case-finding instruments is peripartum period-specific. Published by Elsevier B.V.

  6. 46 CFR 67.209 - No original instrument requirement.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false No original instrument requirement. 67.209 Section 67... original instrument requirement. A copy of the original signed and acknowledged instrument must be presented. The original instrument itself may be presented but is not required. The copy may be delivered to...

  7. Fatigue behavior of lubricated Ni-Ti endodontic rotary instruments

    Directory of Open Access Journals (Sweden)

    A. Brotzu

    2014-04-01

    Full Text Available The use of Ni-Ti alloys in the practice of endodontic comes from their important properties such as shape memory and superelasticity phenomena, good corrosion resistance and high compatibility with biological tissues. In the last twenty years a great variety of nickel-titanium rotary instruments, with various sections and taper, have been developed and marketed. Although they have many advantages and despite their increasing popularity, a major concern with the use of Ni-Ti rotary instruments is the possibility of unexpected failure in use due to several reasons: novice operator handling, presence manufacturing defects, fatigue etc. Recently, the use of an aqueous gel during experimental tests showed a longer duration of the instruments. The aim of the present work is to contribute to the study of the fracture behavior of these endodontic rotary instruments particularly assessing whether the use of the aqueous lubricant gel can extend their operative life stating its reasons. A finite element model (FEM has been developed to support the experimental results. The results were rather contradictory, also because the Perspex (Poly-methyl methacrylate, PMMA cannot simulate completely the dentin mechanical behavior; however the results highlight some interesting points which are discussed in the paper.

  8. 21 CFR 882.4275 - Dowel cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dowel cutting instrument. 882.4275 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4275 Dowel cutting instrument. (a) Identification. A dowel cutting instrument is a device used to cut dowels of bone for bone grafting. (b...

  9. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  10. Distortion product otoacoustic emissions in college music majors and nonmusic majors

    Directory of Open Access Journals (Sweden)

    Rebecca L. Warner Henning

    2016-01-01

    Full Text Available The presence and absence of distortion product otoacoustic emissions (DPOAEs as well as DPOAE amplitudes were compared between college music majors and a control group of nonmusic majors. Participants included 28 music majors and 35 nonmusic majors enrolled at a university with ages ranging from 18-25 years. DPOAEs and hearing thresholds were measured bilaterally on all the participants. DPOAE amplitudes were analyzed at the following f2 frequencies: 1,187 Hz, 1,500 Hz, 1,906 Hz, 2,531 Hz, 3,031 Hz, 3812 Hz, 4,812 Hz, and 6,031 Hz. Significantly more music majors (7/28 than nonmusic majors (0/35 exhibited absent DPOAEs for at least one frequency in at least one ear. Both groups of students reported similar histories of recreational and occupational noise exposures that were unrelated to studying music, and none of the students reported high levels of noise exposure within the previous 48 h. There were no differences in audiometric thresholds between the groups at any frequency. At DPOAE f2 frequencies from 3,031 Hz to 6,031 Hz, nonsignificantly lower amplitudes of 2-4 dB were seen in the right ears of music majors versus nonmajors, and in the right ears of music majors playing brass instruments compared to music majors playing nonbrass instruments. Given the greater prevalence of absent DPOAEs in university music majors compared to nonmusic majors, it appears that early stages of cochlear damage may be occurring in this population. Additional research, preferably longitudinal and across multiple colleges/universities, would be beneficial to more definitively determine when the music students begin to show signs of cochlear damage, and to identify whether any particular subgroups of music majors are at a greater risk of cochlear damage.

  11. 3rd Symposium on Space Optical Instruments and Applications

    CERN Document Server

    Zhang, Guangjun

    2017-01-01

    This volume contains selected and expanded contributions presented at the 3rd Symposium on Space Optical Instruments and Applications in Beijing, China June 28 – 29, 2016. This conference series is organised by the Sino-Holland Space Optical Instruments Laboratory, a cooperation platform between China and the Netherlands. The symposium focused on key technological problems of optical instruments and their applications in a space context. It covered the latest developments, experiments and results regarding theory, instrumentation and applications in space optics. The book is split across five topical sections. The first section covers space optical remote sensing system design, the second advanced optical system design, the third remote sensor calibration and measurement. Remote sensing data processing and information extraction is then presented, followed by a final section on remote sensing data applications. .

  12. Instruments for radiation measurement in biosciences. Series 3. radioluminography. 1. Results of questionnaires to the scientists using radioluminographic techniques

    International Nuclear Information System (INIS)

    Kurihara, Norio; Nakajima, Eiichi; Takahashi, Sentaro

    1998-01-01

    Radioluminography (RLG) is a method to detect radioactivity with its photostimulated luminescence phenomenon. This paper describes major results of questionnaires to the scientists using RLG technique which was performed by the technical subcommittee for research instruments for isotope tracer of Life Science Section, Japan Radioisotope Association. The main purpose was to find the advantage and problems of RLG recognized by users. Questionnaires were sent to 271 users and 101 answers were obtained from pharmaceutical companies, universities and other public research facilities. RLG was found mainly used in gel electrophoresis in the molecular biology field, thin layer chromatography and quantitative whole body autoradiography. RLG technology itself of the instrument, imaging plate and standard usage was found to be in progress as well. Problems were those on the fundamental handling (e.g., ROI definition), on instruments, on quantitativeness, on different nuclides, on value for formal data and on radiation control. The major instrument manufacturers were Fuji Film Co., BioRad Co. and Molecular Dynamics Co. Results of the questionnaire will be published in more detailed form in future. (K.H.)

  13. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  14. 26 CFR 1.1275-7 - Inflation-indexed debt instruments.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Inflation-indexed debt instruments. 1.1275-7... Inflation-indexed debt instruments. (a) Overview. This section provides rules for the Federal income tax treatment of an inflation-indexed debt instrument. If a debt instrument is an inflation-indexed debt...

  15. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Klobe, L.E.E. (ed.)

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed. (WHK)

  16. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    International Nuclear Information System (INIS)

    Klobe, L.E.E.

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced #betta# and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed

  17. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...

  18. ACRF Instrumentation Status: New, Current, and Future January 2007

    Energy Technology Data Exchange (ETDEWEB)

    Liljegren, JC

    2007-01-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  19. ACRF Instrumentation Status: New, Current, and Future October 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  20. ACRF Instrumentation Status: New, Current, and Future May 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  1. ACRF Instrumentation Status: New, Current, and Future February 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-02-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development

  2. ACRF Instrumentation Status: New, Current, and Future May 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-04-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  3. ACRF Instrumentation Status: New, Current, and Future March 2007

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2007-03-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  4. ACRF Instrumentation Status: New, Current, and Future - February 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-03-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  5. ACRF Instrumentation Status: New, Current, and Future - March 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-04-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  6. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    In nine sections, 48 chapters cover 1) analytical chemistry and the environment 2) environmental radiochemistry 3) automated instrumentation 4) advances in analytical mass spectrometry 5) fourier transform spectroscopy 6) analytical chemistry of plutonium 7) nuclear analytical chemistry 8) chemometrics and 9) nuclear fuel technology

  7. Comparison of removed dentin thickness with hand and rotary instruments

    Science.gov (United States)

    Shahriari, Shahriar; Abedi, Hasan; Hashemi, Mahdi; Jalalzadeh, Seyed Mohsen

    2009-01-01

    INTRODUCTION: The aim of this study was to evaluate the amount of dentine removed after canal preparation using stainless steel (SS) hand instruments or rotary ProFile instruments. MATERIALS AND METHODS: Thirty-six extracted human teeth with root canal curvatures less than 30º were embedded in clear polyester resin. The roots were cut horizontally at apical 2, 4 and 7 mm. Dentin thickness was measured at each section and the sections were accurately reassembled using a muffle. Root canals were randomly prepared by SS hand instruments or rotary ProFile instruments. Root sections were again separated, and the remaining dentin thickness was measured. Mann-Whitney U and t tests were performed for analytic comparison of the results. RESULTS: The thickness of removed dentin was significantly different between the two used methods (Pinstrumentation group (Protary instrumentation prepares root canals with a greater conservation of tooth structure. PMID:23940489

  8. Major depression, fibromyalgia and labour force participation: A population-based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Patten Scott B

    2006-01-01

    Full Text Available Abstract Background Previous studies have documented an elevated frequency of depressive symptoms and disorders in fibromyalgia, but have not examined the association between this comorbidity and occupational status. The purpose of this study was to describe these epidemiological associations using a national probability sample. Methods Data from iteration 1.1 of the Canadian Community Health Survey (CCHS were used. The CCHS 1.1 was a large-scale national general health survey. The prevalence of major depression in subjects reporting that they had been diagnosed with fibromyalgia by a health professional was estimated, and then stratified by demographic variables. Logistic regression models predicting labour force participation were also examined. Results The annual prevalence of major depression was three times higher in subjects with fibromyalgia: 22.2% (95% CI 19.4 – 24.9, than in those without this condition: 7.2% (95% CI 7.0 – 7.4. The association persisted despite stratification for demographic variables. Logistic regression models predicting labour force participation indicated that both conditions had an independent (negative effect on labour force participation. Conclusion Fibromyalgia and major depression commonly co-occur and may be related to each other at a pathophysiological level. However, each syndrome is independently and negatively associated with labour force participation. A strength of this study is that it was conducted in a large probability sample from the general population. The main limitations are its cross-sectional nature, and its reliance on self-reported diagnoses of fibromyalgia.

  9. A cross-sectional study of metabolic and endocrine complications in beta-thalassemia major

    International Nuclear Information System (INIS)

    Najafipour, F.; Aliasgarzadeh, A.; Aghamohamadzadeh, N.; Bahrami, A.; Mobasri, M.; Niafar, M.; Khoshbaten, M.

    2008-01-01

    Iron overload is a major problem in patients with beta-thalassemia major, and it has many structural and metabolic consequences. The aim of this study was evaluation of endocrine disturbances in patients with beta-thalassemia major who were older than 10 years of age. In this cross-sectional study, investigator collected demographic data and medical histories, as well as menstrual history in females, from the medical records of 56 patients with beta-thalassemia major. Patients were examined to determine their pubertal status and the standard deviation score for height for evaluation of short stature. For evaluation of glucose tolerance, a fasting blood glucose and oral glucose tolerance tests were performed. Evidence for diabetes mellitus was based on American Diabetes Association and World Health Organization criteria. Serum levels of calcium, phosphorous, thyroid-stimulating hormone, free thyroxin, luteinizing hormone and follicular-stimulating hormone and estradiol in girls and testosterone in boys were measured. The mean and standard deviation for age in the 56 patients (36 males and 20 females) was 15.62+-4.44 years. Diabetes mellitus was present in 5 patients (8.9%), impaired fasting glucose was found in 16 patients (28.6%) and an impaired glucose tolerance test was found in 4 patients (7.1%). Short stature (standard deviation score <-2) was seen in 25 (70%) boys and 14 (73%) girls. Impaired puberty was found in 40 patients (71%). Hypocalcaemia and primary overt hyperthyroidism were present in 23 (41%) and 9 patients (16%), respectively. Only eight patients (14.3%) had no endocrine abnormalities. Despite therapy with deferoxamine to treat iron overload, the risk of secondary endocrine dysfunction remained high. Hypogonadism was one of the most frequent endocrine complications. Impaired glucose tolerance, short stature, hypocalcemia, subclinical and overt hypothyroidism are also frequent. (author)

  10. ARM Climate Research Facility Monthly Instrument Report August 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-09-28

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  11. ACRF Instrumentation Status: New, Current, and Future - April 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  12. ACRF Instrumentation Status: New, Current, and Future - December 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-01-15

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  13. ACRF Instrumentation Status: New, Current, and Future February 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-02-15

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  14. ACRF Instrumentation Status: New, Current, and Future - September 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-10-15

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  15. ACRF Instrumentation Status: New, Current, and Future - July 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-07-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  16. ACRF Instrumentation Status: New, Current, and Future - August 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-09-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  17. ACRF Instrumentation Status: New, Current, and Future - June 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-07-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  18. ACRF Instrumentation Status: New, Current, and Future - October 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  19. ARM Climate Research Facility Monthly Instrument Report September 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-10-18

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  20. ACRF Instrumentation Status: New, Current, and Future March 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-03-15

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  1. ACRF Instrumentation Status: New, Current, and Future - May 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  2. ACRF Instrumentation Status: New, Current, and Future - January 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-03-02

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  3. ARM Climate Research Facility Monthly Instrument Report May 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-06-21

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  4. ACRF Instrumentation Status: New, Current, and Future - November 2008

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-12-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  5. ARM Climate Research Facility Monthly Instrument Report June 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-07-13

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  6. ARM Climate Research Facility Monthly Instrument Report July 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-08-18

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  7. Carbon Footprint Reduction Instruments

    Science.gov (United States)

    This page outlines the major differences between Renewable Energy Certificates (REC) and Project Offsets and what types of claims each instrument allows the organization to make in regards to environmental emissions claims.

  8. MAJOR: AN ASPECT WEAVER WITH FULL COVERAGE SUPPORT

    Directory of Open Access Journals (Sweden)

    Alex Villazón

    2011-01-01

    In this article we present MAJOR, an aspect weaver with full coverage support. That is, MAJOR ensures that aspects are woven into all classes loaded in a Java Virtual Machine, including those in the standard Java class library. We describe the intricacies of instrumentation of the Java class library and present an extended instrumentation approach allowing the user to choose between a pure Java weaving solution based on a two-phases instrumentation scheme, or a single-phase one requiring a tiny native code layer. The single-phase approach allows to better isolate the weaving process from the execution of the woven code.

  9. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs

  10. ACRF Instrumentation Status: New, Current, and Future July 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-07-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

  11. ACRF Instrumentation Status: New, Current, and Future September 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-09-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

  12. ACRF Instrumentation Status: New, Current, and Future August 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-08-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development. New information is highlighted in blue text.

  13. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  14. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  15. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  16. A cross-sectional study of knife injuries at a London major trauma centre.

    Science.gov (United States)

    Pallett, J R; Sutherland, E; Glucksman, E; Tunnicliff, M; Keep, J W

    2014-01-01

    No national recording systems for knife injuries exist in the UK. Understanding the true size and nature of the problem of knife injuries is the first stage in reducing the burden of this injury. The aim of this study was to survey every knife injury seen in a single inner city emergency department (ED) over a one-year period. A cross-sectional observational study was performed of all patients attending with a knife injury to the ED of a London major trauma centre in 2011. Demographic characteristics, patterns of injury, morbidity and mortality data were collected. A total of 938 knife injuries were identified from 127,191 attendances (0.77% of all visits) with a case fatality rate of 0.53%. A quarter (24%) of the major trauma team's caseload was for knife injuries. Overall, 44% of injuries were selfreported as assaults, 49% as accidents and 8% as deliberate self-harm. The highest age specific incident rate occurred in the 16-24 year age category (263/100,000). Multiple injuries were seen in 19% of cases, of which only 81% were recorded as assaults. The mean length of stay for those admitted to hospital was 3.04 days. Intrathoracic injury was seen in 26% of cases of chest trauma and 24% of abdominal injuries had a second additional chest injury. Violent intentional injuries are a significant contributory factor to the workload of the major trauma team at this centre. This paper contributes to a more comprehensive understanding of the nature of these injuries seen in the ED.

  17. ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

    Science.gov (United States)

    1990-01-01

    In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its

  18. 21 CFR 886.4150 - Vitreous aspiration and cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vitreous aspiration and cutting instrument. 886.4150 Section 886.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... cutting instrument. (a) Identification. A vitreous aspiration and cutting instrument is an electrically...

  19. ACRF Instrumentation Status: New, Current, and Future November-December 2006

    Energy Technology Data Exchange (ETDEWEB)

    JC Liljegren

    2006-12-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Program Climate Research Facility instrumentation status. The report is divided into four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  20. Instrumentation in elementary particle physics

    Energy Technology Data Exchange (ETDEWEB)

    Fabjan, C W [European Organization for Nuclear Research, Geneva (Switzerland); Pilcher, J E [Chicago Univ., IL (United States); eds.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs.

  1. Instrumentation in elementary particle physics

    International Nuclear Information System (INIS)

    Fabjan, C.W.; Pilcher, J.E.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs

  2. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  3. Operator/instrumentation interactions during the Three Mile Island incident

    International Nuclear Information System (INIS)

    Cummings, G.E.

    1979-10-01

    A discussion is presented of the operator/instrumentation interactions which had an effect on the course of the incident at the Three Mile Island-2 Nuclear Power Plant. A brief review of the sequence of occurrences at TMI-2 over the first 16 hours of the incident is given with particular emphasis on operator/instrumentation interactions. A breakdown of the six major items that seemed to have contributed to the characteristics of the incident is then given and also an outline of some of the currently proposed operator/instrumentation improvements. The six major items involve water level indication in the reactor, electromatic relief valve operation, auxiliary feed-water flow indication, containment isolation, extended range instrumentation, and computer readout

  4. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  5. ARM Climate Research Facility Instrumentation Status and Information October 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  6. ARM Climate Research Facility Instrumentation Status and Information April 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-05-15

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  7. ARM Climate Research Facility Instrumentation Status and Information January 2010

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2010-02-28

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  8. ARM Climate Research Facility Instrumentation Status and Information March 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-04-19

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  9. ARM Climate Research Facility Instrumentation Status and Information February 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2010-03-25

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  10. ARM Climate Research Facility Instrumentation Status and Information December 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2010-12-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  11. Instrumentation for Air Pollution Monitoring

    Science.gov (United States)

    Hollowell, Craig D.; McLaughlin, Ralph D.

    1973-01-01

    Describes the techniques which form the basis of current commercial instrumentation for monitoring five major gaseous atmospheric pollutants (sulfur dioxide, oxides of nitrogen, oxidants, carbon monoxide, and hydrocarbons). (JR)

  12. Policy instruments for energy conservation and environmental policy in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Bovenberg, A.L. [Tinbergen Inst., Rotterdam (Netherlands)

    1992-03-01

    In this paper it is assumed that the policy objective is not so much to economize on energy as to reduce pollution. In particular, to curb the emissions of carbon dioxide. A number of environmental policy instruments pertaining to fossil fuels are analyzed, mainly in the context of the Dutch economy: regulation, subsidies, voluntary agreements with industry, and taxation. At the moment, most industrial countries, including the Netherlands, rely almost entirely on the first three instruments. More recently, however, there has been a growing interest in environmental taxation. The theory that taxation is always and everywhere the best instrument assumes, however, perfect markets and a closed economy. Most economies, including the Dutch one, are riddled with market imperfections. Hence, policy makers confront a second best case. This implies that in selecting policy instruments, they have to resort to a more pragmatic `case-by-case` approach. A diversified diet is advocated. Taxation is part of that diet. Section 2 explores a number of important advantages of the tax instrument. Section 3 discusses a number of problems if a small open economy like the Netherlands would unilaterally adopt such a tax, especially if that tax would include energy-intensive firms that are subject to international competition. In this connection, some alternative policy instruments are analyzed in Section 4. Section 5 proceeds by investigating the case of international coordination and explores the conditions under which coordinated taxes could be successful. Section 6 analyzes policies targeted at households and at firms that are not subject to international competition. 13 refs.

  13. NASA Instrument Cost Model for Explorer-Like Mission Instruments (NICM-E)

    Science.gov (United States)

    Habib-Agahi, Hamid; Fox, George; Mrozinski, Joe; Ball, Gary

    2013-01-01

    NICM-E is a cost estimating relationship that supplements the traditional NICM System Level CERs for instruments flown on NASA Explorer-like missions that have the following three characteristics: 1) fly on Class C missions, 2) major development led and performed by universities or research foundations, and 3) have significant level of inheritance.

  14. Assessment of the Cross-Sectional Areas of the Psoas Major and Multifidus Muscles in Patients With Adult Spinal Deformity: A Case-Control Study.

    Science.gov (United States)

    Banno, Tomohiro; Yamato, Yu; Hasegawa, Tomohiko; Kobayashi, Sho; Togawa, Daisuke; Oe, Shin; Mihara, Yuki; Kurosu, Kenta; Yamamoto, Naoto; Matsuyama, Yukihiro

    2017-08-01

    This is a case-control study. The present study aimed to compare the cross-sectional areas of the psoas major and multifidus muscles between elderly patients with adult spinal deformity (ASD) and age-matched and body weight-matched controls, and to evaluate the associations between the cross-sectional areas of these muscles and the severity of spinal deformity. The study included 49 female kyphosis patients with mild scoliosis (Cobb angle muscles were calculated using preoperative L4/L5 axial computed tomography images. In group D, the following spinopelvic parameters were assessed: sagittal vertical axis, pelvic tilt, pelvic incidence, lumbar lordosis, and thoracic kyphosis. The relationships between the muscle cross-sectional areas and spinopelvic parameters were evaluated. The cross-sectional area of the multifidus muscle was lower in group D than in group C. However, the cross-sectional area of the psoas major muscle was not different between the 2 groups. In multiple regression analysis, the cross-sectional area of the multifidus muscle was significantly associated with all spinopelvic parameters. The cross-sectional area of the multifidus muscle might be lower in elderly patients with ASD than in controls. In the elderly population, the severity of sagittal spinal deformity might be correlated with the cross-sectional area of the multifidus muscle. Therefore, muscle imbalances between the flexors and extensors of the spine could participate in the pathology of ASD.

  15. ACRF Instrumentation Status: New, Current, and Future - November – December 2007

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2007-12-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  16. ACRF Instrumentation Status: New, Current, and Future - October – November 2007

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2007-11-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.

  17. 21 CFR 886.1360 - Visual field laser instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual field laser instrument. 886.1360 Section 886.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument...

  18. Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments.

    Science.gov (United States)

    Vaudt, J; Bitter, K; Neumann, K; Kielbassa, A M

    2009-01-01

    To investigate instrumentation time, working safety and the shaping ability of two rotary nickel-titanium (NiTi) systems (Alpha System and ProTaper Universal) in comparison to stainless steel hand instruments. A total of 45 mesial root canals of extracted human mandibular molars were selected. On the basis of the degree of curvature the matched teeth were allocated randomly into three groups of 15 teeth each. In group 1 root canals were prepared to size 30 using a standardized manual preparation technique; in group 2 and 3 rotary NiTi instruments were used following the manufacturers' instructions. Instrumentation time and procedural errors were recorded. With the aid of pre- and postoperative radiographs, apical straightening of the canal curvature was determined. Photographs of the coronal, middle and apical cross-sections of the pre- and postoperative canals were taken, and superimposed using a standard software. Based on these composite images the portion of uninstrumented canal walls was evaluated. Active instrumentation time of the Alpha System was significantly reduced compared with ProTaper Universal and hand instrumentation (P < 0.05; anova). No instrument fractures occurred in any of the groups. The Alpha System revealed significantly less apical straightening compared with the other instruments (P < 0.05; Mann-Whitney U test). In the apical cross-sections Alpha System resulted in significantly less uninstrumented canal walls compared with stainless steel files (P < 0.05; chi-squared test). Despite the demonstrated differences between the systems, an apical straightening effect could not be prevented; areas of uninstrumented root canal wall were left in all regions using the various systems.

  19. Azimuthal Signature of Coincidental Brightness Temperature and Normalized Radar Cross-Section Obtained Using Airborne PALS Instrument

    Science.gov (United States)

    Colliander, Andreas; Kim, Seungbum; Yueh, Simon; Cosh, Mike; Jackson, Tom; Njoku, Eni

    2010-01-01

    Coincidental airborne brightness temperature (TB) and normalized radar-cross section (NRCS) measurements were carried out with the PALS (Passive and Active L- and S-band) instrument in the SMAPVEX08 (SMAP Validation Experiment 2008) field campaign. This paper describes results obtained from a set of flights which measured a field in 45(sup o) steps over the azimuth angle. The field contained mature soy beans with distinct row structure. The measurement shows that both TB and NRCS experience modulation effects over the azimuth as expected based on the theory. The result is useful in development and validation of land surface parameter forward models and retrieval algorithms, such as the soil moisture algorithm for NASA's SMAP (Soil Moisture Active and Passive) mission. Although the footprint of the SMAP will not be sensitive to the small resolution scale effects as the one presented in this paper, it is nevertheless important to understand the effects at smaller scale.

  20. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  1. IAEA programme on maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1986-01-01

    The Medical Applications Section in the Division of Life Sciences of the International Atomic Energy Agency has been engaged since 1975 in activities aimed at the more effective use of nuclear instruments. Activities and achievements are described concerning the conditioning of laboratories, preventive maintenance and repair of instruments, the management thereof, space parts and the promotion of local training in these subjects. (author)

  2. 26 CFR 1.508-3 - Governing instruments.

    Science.gov (United States)

    2010-04-01

    ... foundation shall not be exempt from taxation under section 501(a) for a taxable year unless by the end of... described in section 4947(a)) that its governing instrument contains no mandatory directions which conflict...(e), such organization will not be exempt from taxation. (6) Retroactive application to grants or...

  3. Commissioning of the STAR test section for experimental simulation of loss of coolant accident using the EC-208 instrumented fuel assembly of the IEA-R1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maprelian, Eduardo; Torres, Walmir M.; Prado, Adelk C.; Umbehaun, Pedro E.; Franca, Renato L.; Santos, Samuel C.; Macedo, Luiz A.; Sabundjian, Gaiane, E-mail: emaprel@ipen.br, E-mail: wmtorres@ipen.br, E-mail: acprado@ipen.br, E-mail: umbehaun@ipen.br, E-mail: rlfranca@ipen.br, E-mail: samuelcs@ipen.br, E-mail: lamacedo@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SO (Brazil)

    2015-07-01

    The three basic safety functions of Research Reactors (RR) are the safe shutdown of the reactor, the proper cooling of the decay heat of the fuel elements and the confinement of radioactive materials. Compared to Nuclear Power Reactors, RR power release is small, yet its three safety functions must be met to ensure the integrity of the reactor. During a loss of coolant accident (LOCA) in pool type RR, partial or complete loss of pool water may occur, with consequent partial or complete uncovering of the fuel assemblies. In such an accident, the decay heat removal safety function must not be compromised. The Test Section for Experimental Simulation of Loss of Coolant Accident (STAR) is in commissioning phase. This test section will provide experimental data on partial and total uncovering of the EC-208 instrumented fuel assembly (IFA) irradiated in the IEA-R1. Experimental results will be useful in validation of computer codes for RR safety analysis, particularly on heat removal efficiency aspects (safety function) in accident conditions. STAR comprises a base on which is installed the IFA, the cylindrical stainless steel hull, the compressed air system for the test section emptying and refilling, and the instrumentation for temperature and level measurements. The commissioning tests or pre-operational check, consist of several preliminary tests to verify experimental procedures, the difficulties during assembling of STAR in the pool, the difficulties in control the emptying and refilling velocities, as well as, the repeatability capacity, tests of equipment, valves and systems and tests of instrumentation and data acquisition system. Safety, accuracy and easiness of operation will be checked. (author)

  4. Upgrade of Instrumentation for Purdue Reactor PUR-1

    International Nuclear Information System (INIS)

    Revankar, S.T.; Merritt, E.; Bean, R.

    2000-01-01

    The major objective of this program was to upgrade and replace instruments and equipment that significantly improve the performance, control and operational capability of the Purdue University nuclear reactor (PUR-1). Under this major objective two projects on instrument upgrade were implemented. The first one was to convert the vacuum tube control and safety amplifiers (CSA) to solid state electronics, and the other was to upgrade the electrical and electronic shielding. This report is the annual report and gives the efforts and progress achieved on these two projects from July 1999 to June 2000

  5. 78 FR 55118 - Seismic Instrumentation for Nuclear Power Plants

    Science.gov (United States)

    2013-09-09

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0202] Seismic Instrumentation for Nuclear Power Plants... Reports for Nuclear Power Plants: LWR Edition,'' Section 3.7.4, ``Seismic Instrumentation.'' DATES: Submit... Nuclear Power Plants: LWR Edition'' (SRP, from the current Revision 2 to a new Revision 3). The proposed...

  6. Apical instrumentation in endodontic therapy

    Directory of Open Access Journals (Sweden)

    Kurniasri Darliana

    2007-07-01

    Full Text Available Cleaning and shaping of the root canal as the foundation for successful endodontic therapy. Cleaning of the root canal as the removal of all the contents of the root canal systems before and during shaping. Mechanical cleaning as the most important part of the root canal therapy. Instrumentation of the apical region has long been considered to be an essential component in the cleaning and shaping process. The apical area as the critical zone for instrumentation. The apical portion of the root canal system can retain microorganisms that could potentially cause periradicular inflammation. The nickel-titanium rotary instrumentation system to facilitate the cleaning and shaping process. Larger instrumentation sizes not only allow proper irrigation but also significantly decrease remaining bacteria in the canal system. How the larger apical sizes preparation must be achieved to clinical success. This paper will describe the major factors impacting the selection of final apical size, the factors are the anatomy of the apical constriction, root canal diameter, apical instrumentation, and bacteria in dentin tubuli.

  7. Mechanical properties of ProTaper Gold nickel-titanium rotary instruments.

    Science.gov (United States)

    Elnaghy, A M; Elsaka, S E

    2016-11-01

    To evaluate and compare the resistance to cyclic fatigue and torsional stress, flexibility and surface microhardness of ProTaper Gold (PTG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) system with ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). PTG and PTU instruments were rotated in simulated canals and the number of cycles to failure was recorded to assess their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing firmly the apical 3 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the broken instruments. The instruments were tested for bending resistance using cantilever-bending test. Vickers microhardness was measured on the cross section of instruments with 300 g load and 15 s dwell time. Data were analysed statistically using independent t-tests. Statistical significance was set at P hand, PTU instruments were associated with higher resistance to torsional stress and microhardness than PTG instruments (P < 0.001). After torsional tests, the fractured cross-sectional surfaces revealed skewed dimples near the centre of the fracture surfaces and circular abrasion streaks. The PTG instrument had improved resistance to cyclic fatigue and flexibility compared with PTU. PTU instruments had improved resistance to torsional stress and microhardness compared with PTG. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Basics of radiation physics and instrumentation

    International Nuclear Information System (INIS)

    Royal, H.D.

    1985-01-01

    Continued technical developments are greatly changing medical diagnosis and medical care. In the field of cardiology, a number of new imaging techniques are currently available. This chapter reviews several topics that are important in the practice of nuclear cardiology. The first section discusses some of the basics of nuclear physics. Familiarity with these fundamentals is essential for an in-depth understanding of nuclear cardiology. The second section presents information on radiotracers and provides dosimetry estimates for commonly performed studies. The third section reviews the instruments used to detect radioactivity. The final section discusses computers and their applications and limitations in nuclear cardiology

  9. Sulfur Dioxide Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, Stephen R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-05-01

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

  10. Research on Web-Based Networked Virtual Instrument System

    International Nuclear Information System (INIS)

    Tang, B P; Xu, C; He, Q Y; Lu, D

    2006-01-01

    The web-based networked virtual instrument (NVI) system is designed by using the object oriented methodology (OOM). The architecture of the NVI system consists of two major parts: client-web server interaction and instrument server-virtual instrument (VI) communication. The web server communicates with the instrument server and the clients connected to it over the Internet, and it handles identifying the user's name, managing the connection between the user and the instrument server, adding, removing and configuring VI's information. The instrument server handles setting the parameters of VI, confirming the condition of VI and saving the VI's condition information into the database. The NVI system is required to be a general-purpose measurement system that is easy to maintain, adapt and extend. Virtual instruments are connected to the instrument server and clients can remotely configure and operate these virtual instruments. An application of The NVI system is given in the end of the paper

  11. An introduction to biomedical instrumentation

    CERN Document Server

    Dewhurst, D J

    1976-01-01

    An Introduction to Biomedical Instrumentation presents a course of study and applications covering the basic principles of medical and biological instrumentation, as well as the typical features of its design and construction. The book aims to aid not only the cognitive domain of the readers, but also their psychomotor domain as well. Aside from the seminar topics provided, which are divided into 27 chapters, the book complements these topics with practical applications of the discussions. Figures and mathematical formulas are also given. Major topics discussed include the construction, handli

  12. The Role of Accompaniment Quality in the Evaluation of Solo Instrumental Performance

    Science.gov (United States)

    Springer, D. Gregory; Silvey, Brian A.

    2018-01-01

    The purpose of this study was to examine the effect of accompaniment quality on the evaluation of solo instrumental performance. Undergraduate instrumental music education majors (N = 71) listened to and evaluated the accuracy and expressivity of six excerpts of Haydn's "Concerto for Trumpet in E-Flat Major," which we created by…

  13. Interference between work and nonwork roles: The development of a new South African instrument

    Directory of Open Access Journals (Sweden)

    Eileen Koekemoer

    2010-10-01

    Research purpose: The purpose of this study was to, (1 develop new items for a more comprehensive work−nonwork interference instrument, (2 evaluate the newly developed items to retain those items that accurately capture the different dimensions and (3 eliminate undesirable items from the different subscales in the instrument. Motivation for the study: Although the interaction between work and personal life has received extensive attention in the work−family fields of research, various theoretical, empirical and measurement issues need to be addressed. Research design, approach and method: A cross-sectional survey design was used to collect the data. Main findings: Initially, 89 items were developed. During the pilot study among mineworkers (n = 245, 41 poor items were eliminated on the basis of descriptive statistics, inter-item correlations, item-total correlations and the qualitative investigation of items highly redundant in terms of wording. Thereafter, the instrument (48 items was administered to 366 support and academic personnel at a tertiary institution. Using Rasch analyses and item correlations, 18 additional items were eliminated, resulting in a 30-item instrument (15 items were retained to measure work-nonwork interference and 15 items to measure nonwork-work interference. Practical/managerial implications: A major theoretical limitation to the measurement of work−family interference relates to the dimensionality and inconsistent measurement of the directionality of interference. Contribution/value-add: With the development of this new instrument, several of the theoretical and measurement limitations voiced by previous researchers have been addressed, providing this instrument with distinct advantages over previous work−family instruments.

  14. Instrumental systematics and weak gravitational lensing

    International Nuclear Information System (INIS)

    Mandelbaum, R.

    2015-01-01

    We present a pedagogical review of the weak gravitational lensing measurement process and its connection to major scientific questions such as dark matter and dark energy. Then we describe common ways of parametrizing systematic errors and understanding how they affect weak lensing measurements. Finally, we discuss several instrumental systematics and how they fit into this context, and conclude with some future perspective on how progress can be made in understanding the impact of instrumental systematics on weak lensing measurements

  15. 26 CFR 1.1275-5 - Variable rate debt instruments.

    Science.gov (United States)

    2010-04-01

    ... nonpublicly traded property. A debt instrument (other than a tax-exempt obligation) that would otherwise... variations in the cost of newly borrowed funds in the currency in which the debt instrument is denominated... on the yield of actively traded personal property (within the meaning of section 1092(d)(1)). (ii...

  16. Safeguards instrumentation: past, present, future

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    1982-01-01

    Instruments are essential for accounting, for surveillance and for protection of nuclear materials. The development and application of such instrumentation is reviewed, with special attention to international safeguards applications. Active and passive nondestructive assay techniques are some 25 years of age. The important advances have been in learning how to use them effectively for specific applications, accompanied by major advances in radiation detectors, electronics, and, more recently, in mini-computers. The progress in seals has been disappointingly slow. Surveillance cameras have been widely used for many applications other than safeguards. The revolution in TV technology will have important implications. More sophisticated containment/surveillance equipment is being developed but has yet to be exploited. On the basis of this history, some expectations for instrumentation in the near future are presented

  17. Instrument for track linear element recognition

    International Nuclear Information System (INIS)

    Krupnov, V.E.; Fedotov, O.P.

    1977-01-01

    Described is the construction of instrument for recognizing linear elements of tracks. For designing this instrument use has been made of the algorithm for conversion of the point data into a set of linear elements. The flowsheet of the instrument shows its major units such as data converter, data representation register unit, local computers, interface with the central computer. The data representation register unit comprises sixteen registers and is capable of presenting data from sixteen lines when raster scanning of a picture taken from a track chamber. The maximum capacity of the code of the coordinate of a point recorded on a picture is up to 16 digits. The time of the inner operating cycle of the instrument is 1.3 μs. The average time required for processing data containing sixteen scanning lines is 250 μs

  18. Atmospheric Radiation Measurement Climate Research Facility (ACRF Instrumentation Status: New, Current, and Future)

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2008-01-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  19. Activities of Radiation Standard Section

    International Nuclear Information System (INIS)

    Kannan, A.; Rao, P.S.; Sachadev, R.N.; Shaha, V.V.; Sharma, D.; Srivastava, P.K.

    1992-01-01

    A brief account of the various facilities and services provided by the Radiation Standards Section (RSS) of the Bhabha Atomic Research Centre, Bombay is given. RSS maintains the primary and secondary standards of various parameters of radiation measurements. It ensures accurate radiological measurements as per international requirements, through periodic international intercomparisons of national standards. It also provides calibration services to various users of radiation sources and instruments. The activities of RSS are described under the headings: (1) Radiological Metrology Standards, (2) Radionuclide Standards, Neutron Metrology, (4) Instruments Calibration, (5) Non-ionizing Radiations, and (6) Instrumentation. (author). figs., tabs

  20. Advances in instrumentation for nuclear astrophysics

    Directory of Open Access Journals (Sweden)

    S. D. Pain

    2014-04-01

    Full Text Available The study of the nuclear physics properties which govern energy generation and nucleosynthesis in the astrophysical phenomena we observe in the universe is crucial to understanding how these objects behave and how the chemical history of the universe evolved to its present state. The low cross sections and short nuclear lifetimes involved in many of these reactions make their experimental determination challenging, requiring developments in beams and instrumentation. A selection of developments in nuclear astrophysics instrumentation is discussed, using as examples projects involving the nuclear astrophysics group at Oak Ridge National Laboratory. These developments will be key to the instrumentation necessary to fully exploit nuclear astrophysics opportunities at the Facility for Rare Isotope Beams which is currently under construction.

  1. Cross-sectional validation of the Aging Perceptions Questionnaire: a multidimensional instrument for assessing self-perceptions of aging.

    LENUS (Irish Health Repository)

    Barker, Maja

    2007-01-01

    BACKGROUND: Self-perceptions of aging have been implicated as independent predictors of functional disability and mortality in older adults. In spite of this, research on self-perceptions of aging is limited. One reason for this is the absence of adequate measures. Specifically, there is a need to develop a measure that is theoretically-derived, has good psychometric properties, and is multidimensional in nature. The present research seeks to address this need by adopting the Self-Regulation Model as a framework and using it to develop a comprehensive, multi-dimensional instrument for assessing self-perceptions of aging. This study describes the validation of this newly-developed instrument, the Aging Perceptions Questionnaire (APQ). METHODS: Participants were 2,033 randomly selected community-dwelling older (+65 yrs) Irish adults who completed the APQ alongside measures of physical and psychological health. The APQ assesses self-perceptions of aging along eight distinct domains or subscales; seven of these examine views about own aging, these are: timeline chronic, timeline cyclical, consequences positive, consequences negative, control positive, control negative, and emotional representations; the eighth domain is the identity domain and this examines the experience of health-related changes. RESULTS: Mokken scale analysis showed that the majority of items within the views about aging subscales were strongly scalable. Confirmatory factor analysis also indicated that the model provided a good fit for the data. Overall, subscales had good internal reliabilities. Hierarchical linear regression was conducted to investigate the independent contribution of APQ subscales to physical and psychological health and in doing so determine the construct validity of the APQ. Results showed that self-perceptions of aging were independently related to physical and psychological health. Mediation testing also supported a role for self-perceptions of aging as partial mediators in

  2. Reactor instrumentation experience at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, A.J.

    1997-01-01

    The Instituto de Pesquisas Energeticas e Nucleares (IPEN) in Sao Paulo started in 1977 development of nuclear instrumentation. In 1982 two groups were established, one responsible for maintenance of electronic equipment and the other, the Nuclear Instrumentation Section (NIS), for new projects, such as a light water moderated critical facility (IPEN/MB-0). The NIS had the responsibility to execute all necessary activities to develop the ''nonconventional'' instrumentation systems: control, protection and radiation monitoring for the IPEN/MB-01 facility. After the commissioning of the critical facility the NIS group started the development of instrumentation systems for a power reactor. As a first step an overall review of the quality assurance programme was implemented. In parallel the development of self powered detectors was carried out. (author). 7 figs

  3. Instrumental analytical techniques in geochemistry: Requirements and applications

    International Nuclear Information System (INIS)

    Willis, J.P.

    1986-01-01

    Geochemists must analyse an extremely wide range of terrestrial and planetary materials. The instrumental techniques necessary to cope with this difficult task are considered. The most important analytical techniques in use by the geochemist today are AAS, ICP-OES, INAA, MSID and XRFS, and the electron microscope for in situ mineral analysis. Some applications of these techniques to solving major problems in geochemistry are discussed. The importance of certified reference materials and of high quality geochemical data are emphasized. It is concluded that the general quality of trace element data has improved over the past 25 years, as a direct result of the application of modern instrumental techniques. Surprisingly, the quality of data reported for certain major elements has deteriorated over that time, when compared with data obtainable by classical chemical methods. Predictions are made concerning the instrumentation needs of the next generation of geochemists. (orig.) [de

  4. Major, trace and rate earth elements in sediments of the Julian Adame-Alatorre dam by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mireles, F.; Pinedo, J. L.; Davila, J. I.; Oliva, J. E.; Speakman, R. J.; Glascock, M. D.

    2010-10-01

    The rapid industrial development in regions of Mexico during recent years has had the side effect of introducing toxic metals, fertilizers, and pesticides into the ecosystem. Sediment cores were collected from eight locations around the Julian Adame-Alatorre dam located in Municipality of Villanueva in the Zacatecas State, Mexico. The cores were analyzed for 32 major, trace, and rare earth elements (As, La, Lu, Nd, Sm, U, Yb, Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Ta, Tb, Th, Zn, Zr, Al, Ba, Ca, Dy, K, Mn, Na, Ti, V) in order to estimate the health risk. The samples were analyzed by instrument neutron activation analysis using thermal neutron fluxes of 8 x 10 13 and 5 x 10 13 n cm -2 s -1 for short and long irradiations, respectively. The results of the contamination levels for elements such as As, Ba, Cr, Fe, Mn, Ta, V, and Zn were compared with the Mexican regulations and the guidelines of US EPA. (Author)

  5. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  6. Integrated Instrumentation for Light-Emitting Polymers Development

    National Research Council Canada - National Science Library

    Jen, Alex

    2000-01-01

    The major objective of this project is to develop an integrated instrumentation that combines the capability of performing spin coating of uniform polymer thin films under an oxygen and moisture free...

  7. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  8. Safety Research Experiment Facility Project. Conceptual design report. Volume VIII. Instrumentation and control

    International Nuclear Information System (INIS)

    1975-01-01

    Included are sections dealing with the following: nuclear instrumentation system, reactor control system, plant protection system, plant annunciator system, data acquisition system, and reactor cooling system instrumentation and control

  9. High-Performance Operational and Instrumentation Amplifiers

    NARCIS (Netherlands)

    Shahi, B.

    2015-01-01

    This thesis describes techniques to reduce the offset error in precision instrumentation and operational amplifiers. The offset error which is considered a major error source associated with gain blocks, together with other errors are reviewed. Conventional and newer approaches to remove offset and

  10. 21 CFR 864.5400 - Coagulation instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  11. Handbook on care, handling and protection of nuclear medicine instruments

    International Nuclear Information System (INIS)

    2000-11-01

    Instruments are fundamental to successful nuclear medicine practice. They must be properly installed in an environment in which they can give accurate and uninterrupted service. They have to be properly and carefully operated and supported throughout their life by regular care and maintenance. If something is wrong with a key instrument all well trained staff members are idle and all purchased radiopharmaceuticals become useless. Overall responsibility for instrumentation rests with the directors of nuclear medicine centres. They should support their electronic engineers, medical physicists, technologists and physicians to plan and implement the care and protection of nuclear medicine instruments, see that they are properly maintained, and kept in optimum working condition by regular checks. Protection should be considered, and provided for, before installing any new instrument. The protective devices are part of the new installation and should be well maintained along with the instrument throughout its life. Thus protection needs careful planning, particularly at the beginning of a new instrumentation programme. It can affect selection, procurement, acceptance testing, and the design of quality control and maintenance routines. These activities should be considered as important in their own right. They should not be mixed in with other functions or left to take care of themselves in the daily rush to get through routine work. Experience suggests that more than half of all failures of electronic equipment are due to damage by external electrical disturbances. Section 2 of this handbook aims to help instrument users in nuclear medicine centres to understand the nature of the various types of disturbance, and to protect against them. Section 3 shows how air conditioning can help to protect instrumentation. Section 4 lists some practical tips to avoid accidental damage due to mishandling. A computer program for use with Personal Computers, ''EPC Expert'' is described

  12. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Science.gov (United States)

    2010-04-01

    ... replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... § 874.3540 Prosthesis modification instrument for ossicular replacement surgery. (a) Identification. A prosthesis modification instrument for ossicular replacement surgery is a device intended for use by a...

  13. Technical memorandum: instrumentation for APT and LTPP

    CSIR Research Space (South Africa)

    Steyn, WJvdM

    2006-01-01

    Full Text Available . In these phases, the parameters to be monitored on APT and LTPP sections have been identified, appropriate instruments and sensors for monitoring these parameters have been identified, and recommendations made regarding new developments, required upgrading...

  14. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research. A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones. This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties. We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care integration (33%) and patient

  15. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research.A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones.This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties.We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Context Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Methods Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. Findings From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care

  16. Quality Assurance for Space Instruments Built with COTS

    DEFF Research Database (Denmark)

    Guldager, Peter Buch; Thuesen, Gøsta Guldbæk; Jørgensen, John Leif

    2005-01-01

    be changed at any time and have major consequences to the components ability to survive the space environment. A safe way to protect to components, which are not Latch-Up immune, is to protect the components with a Latch-Up protection circuit. A strict control has to be established, when procuring COTS......Instruments for space can be built with COTS. However no radiation data are available for COTS, so the only way to ensure that the components can survive the space environment is to irradiate each component. Samples from each Lot have to be irradiated, because the manufac-turing process can...... component, testing and manufacturing the instrument before the instrument is qualified for space. By having a strict control with instrument built with COTS, it is possible to manufacture a reliable instrument as with Rad-Hard components....

  17. Determinants of The Application of Macro Prudential Instruments

    Directory of Open Access Journals (Sweden)

    Zakaria Firano

    2017-09-01

    Full Text Available The use of macro prudential instruments today gives rise to a major debate within the walls of central banks and other authorities in charge of financial stability. Contrary to micro prudential instruments, whose effects remain limited, macro prudential instruments are different in nature and can affect the stability of the financial system. By influencing the financial cycle and the financial structure of financial institutions, the use of such instruments should be conducted with great vigilance as well as macroeconomic and financial expertise. But the experiences of central banks in this area are sketchy, and only some emerging countries have experience using these types of instruments in different ways. This paper presents an analysis of instruments of macro prudential policy and attempts to empirically demonstrate that these instruments should be used only in specific economic and financial situations. Indeed, the results obtained, using modeling bivariate panel, confirm that these instruments are more effective when used to mitigate the euphoria of financial and economic cycles. In this sense, the output gap, describing the economic cycle, and the Z-score are the intermediate variables for the activation of capital instruments. Moreover, the liquidity ratio and changes in bank profitability are the two early warning indicators for activation of liquidity instruments.

  18. Prevalence and relationship between major depressive disorder and lung cancer: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Maneeton B

    2014-05-01

    Full Text Available Benchalak Maneeton,1 Narong Maneeton,1 Jirayu Reungyos,1 Suthi Intaprasert,1 Samornsri Leelarphat,1 Sumitra Thongprasert21Department of Psychiatry, 2Department of Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, ThailandObjective: The aims of this study were to estimate the prevalence and examine the factors associated with major depressive disorder (MDD in lung cancer patients.Materials and methods: This cross-sectional study was carried out in the oncology clinic of the University Hospital, Chiang Mai University, Thailand. Patients with all stages of lung cancer were included in this study. Demographic data of eligible patients were gathered. The Mini-International Neuropsychiatric Interview, Thai version 5.0.0 was used to identify MDD. The Thai version of the Personal Health Questionnaire Depression Scale was used to assess depression severity.Results: A total of 146 lung cancer patients from the outpatient clinic from July to December 2012 were approached. The 104 patients were included and analyzed in this study. Based on the Mini-International Neuropsychiatric Interview, 14.4% of them were defined as having MDD. Multiple linear regression analysis revealed that Chalder Fatigue Scale, Functional Assessment of Cancer Therapy – Lung, and Pittsburgh Sleep Quality Index scores were significantly correlated with MDD in lung cancer patients.Conclusion: The results suggest that MDD is more prevalent in lung cancer patients. In addition, fatigue, poor quality of life, and sleep disturbance may increase associated MDD. Because of the small sample size, further studies should be conducted to confirm these results.Keywords: lung cancer, major depressive disorder, prevalence

  19. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  20. Image reconstruction design of industrial CT instrument for teaching

    International Nuclear Information System (INIS)

    Zou Yongning; Cai Yufang

    2009-01-01

    Industrial CT instrument for teaching is applied to teaching and study in field of physics and radiology major, image reconstruction is an important part of software on CT instrument. The paper expatiate on CT physical theory and first generation CT reconstruction algorithm, describe scan process of industrial CT instrument for teaching; analyze image artifact as result of displacement of rotation center, implement method of center displacement correcting, design and complete image reconstruction software, application shows that reconstructed image is very clear and qualitatively high. (authors)

  1. Evaluation of robotically controlled advanced endoscopic instruments

    NARCIS (Netherlands)

    Reilink, Rob; Kappers, Astrid M.L.; Stramigioli, Stefano; Misra, Sarthak

    Background Advanced flexible endoscopes and instruments with multiple degrees of freedom enable physicians to perform challenging procedures such as the removal of large sections of mucosal tissue. However, these advanced endoscopes are difficult to control and require several physicians to

  2. Finite Element Study on Continuous Rotating versus Reciprocating Nickel-Titanium Instruments.

    Science.gov (United States)

    El-Anwar, Mohamed I; Yousief, Salah A; Kataia, Engy M; El-Wahab, Tarek M Abd

    2016-01-01

    In the present study, GTX and ProTaper as continuous rotating endodontic files were numerically compared with WaveOne reciprocating file using finite element analysis, aiming at having a low cost, accurate/trustworthy comparison as well as finding out the effect of instrument design and manufacturing material on its lifespan. Two 3D finite element models were especially prepared for this comparison. Commercial engineering CAD/CAM package was used to model full detailed flute geometries of the instruments. Multi-linear materials were defined in analysis by using real strain-stress data of NiTi and M-Wire. Non-linear static analysis was performed to simulate the instrument inside root canal at a 45° angle in the apical portion and subjected to 0.3 N.cm torsion. The three simulations in this study showed that M-Wire is slightly more resistant to failure than conventional NiTi. On the other hand, both materials are fairly similar in case of severe locking conditions. For the same instrument geometry, M-Wire instruments may have longer lifespan than the conventional NiTi ones. In case of severe locking conditions both materials will fail similarly. Larger cross sectional area (function of instrument taper) resisted better to failure than the smaller ones, while the cross sectional shape and its cutting angles could affect instrument cutting efficiency.

  3. Large electron capture-cross-section of the major nonradiative recombination centers in Mg-doped GaN epilayers grown on a GaN substrate

    Science.gov (United States)

    Chichibu, S. F.; Shima, K.; Kojima, K.; Takashima, S.; Edo, M.; Ueno, K.; Ishibashi, S.; Uedono, A.

    2018-05-01

    Complementary time-resolved photoluminescence and positron annihilation measurements were carried out at room temperature on Mg-doped p-type GaN homoepitaxial films for identifying the origin and estimating the electron capture-cross-section ( σ n ) of the major nonradiative recombination centers (NRCs). To eliminate any influence by threading dislocations, free-standing GaN substrates were used. In Mg-doped p-type GaN, defect complexes composed of a Ga-vacancy (VGa) and multiple N-vacancies (VNs), namely, VGa(VN)2 [or even VGa(VN)3], are identified as the major intrinsic NRCs. Different from the case of 4H-SiC, atomic structures of intrinsic NRCs in p-type and n-type GaN are different: VGaVN divacancies are the major NRCs in n-type GaN. The σ n value approximately the middle of 10-13 cm2 is obtained for VGa(VN)n, which is larger than the hole capture-cross-section (σp = 7 × 10-14 cm2) of VGaVN in n-type GaN. Combined with larger thermal velocity of an electron, minority carrier lifetime in Mg-doped GaN becomes much shorter than that of n-type GaN.

  4. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  5. ARM Climate Research Facility Quarterly Instrument Report Fourth Quarter: October 1–December 30, 2010

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2011-01-17

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

  6. Major, trace and rate earth elements in sediments of the Julian Adame-Alatorre dam by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mireles, F.; Pinedo, J. L.; Davila, J. I.; Oliva, J. E. [Universidad Autonoma de Zacatecas, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Speakman, R. J. [Museum Conservation Institute, Smithsonian Institution, Suitland, MD 20746 (United States); Glascock, M. D., E-mail: fmireles@uaz.edu.m [Research Reactor Center, University of Missouri, Columbia, MO 65211 (United States)

    2010-10-15

    The rapid industrial development in regions of Mexico during recent years has had the side effect of introducing toxic metals, fertilizers, and pesticides into the ecosystem. Sediment cores were collected from eight locations around the Julian Adame-Alatorre dam located in Municipality of Villanueva in the Zacatecas State, Mexico. The cores were analyzed for 32 major, trace, and rare earth elements (As, La, Lu, Nd, Sm, U, Yb, Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Ta, Tb, Th, Zn, Zr, Al, Ba, Ca, Dy, K, Mn, Na, Ti, V) in order to estimate the health risk. The samples were analyzed by instrument neutron activation analysis using thermal neutron fluxes of 8 x 10{sup 13} and 5 x 10{sup 13} n cm{sup -2} s{sup -1} for short and long irradiations, respectively. The results of the contamination levels for elements such as As, Ba, Cr, Fe, Mn, Ta, V, and Zn were compared with the Mexican regulations and the guidelines of US EPA. (Author)

  7. Instrumentation of steam cycle HTR's up to 900 MWe

    International Nuclear Information System (INIS)

    Leithner, D.E.; Winkenbach, B.

    1982-06-01

    Due to basic design features and inherent safety qualities in-core instrumentation is not needed in an HTR. Reactor safety requirements can be met by integral measurements. A modest spatial resolving power of the out-of-core instrumentation is sufficient for all operational purposes in small and medium sized steam cycle HTR's. Thus, the instrumentation concept of the THTR 300 MWe prototype reactor can be adopted without major changes for the HTR 450 MWe reactor project, as is demonstrated here for the neutron flux and temperature measurements. (author)

  8. New instruments for radiation protection

    International Nuclear Information System (INIS)

    Bartos, D.; Ciobanu, M.; Constantin, F.; Petcu, M.; Plostinaru, V.D.; Rusu, Al.; Lupu, A.C.; Lupu, F.

    2003-01-01

    Though a century old, the radiation protection is actual by its purpose: a dose as low as reasonable achievable is to be received either by involved professionals or population. This threshold is dependent on the technical progress. Some major developments like surface mounted device technology, consumer almost ideal operational amplifiers, microcontrollers and the news signal digital processing techniques, offer the opportunity to design improved instruments for radioprotection. To put in a light portable instrument both the whole measuring system and the 'intelligence' - a microcontroller and the associated software - are the main ideas applied by the authors. The result is presented: a family of eight members, at least, based on two parents. (authors)

  9. 78 FR 13860 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2013-03-01

    ... Scientific Instruments Pursuant to Section 6(c) of the Educational, Scientific and Cultural Materials... invite comments on the question of whether instruments of equivalent scientific value, for the purposes... conformational change of assemblies involved in biological processes such as ATP production, signal transduction...

  10. 76 FR 56156 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2011-09-12

    ... Scientific Instruments Pursuant to Section 6(c) of the Educational, Scientific and Cultural Materials... invite comments on the question of whether instruments of equivalent scientific value, for the purposes... materials for energy production. The experiments will involve structural and chemical analyses of materials...

  11. Modernization of ILL instrument electronics

    International Nuclear Information System (INIS)

    Descamps, F.

    1999-01-01

    We have built new general purpose cards for data acquisition taking advantage of recent developments in electronics. At the end of the year, most scheduled instruments at the ILL will be running under UNIX with VME electronics front-end. As the VME electronics of the ILL was designed at the beginning of the eighties, the instrument control section (SCI) at ILL has prepared a renewal plan for two reasons: - first, all the processor cards of the Institute are based on MIZAR processor boards and MIZAR stopped the production of this card last year, as the market was shrinking; - in addition, processors and programmable electronics are now 10 times faster. The electronics services want to take full advantage of these new performances. (author)

  12. [Torque resistance of three different types of nickel-titanium rotary instruments].

    Science.gov (United States)

    Sun, Wei; Hou, Ben-xiang

    2010-10-01

    To compare torsional fracture of three different types of nickel-titanium rotary instruments ProTaper, Hero642 and Mtwo by making a stimulate models in vitro. Through the establishment of model in vitro, compared the different time with 3 kinds of nickel titanium file in cutting-edge bound occurs, and to observe the section of fractured instruments by scanning electron microscope. The resistence to torque was different from three types of nickel titanium instruments. The time to fracture of Mtwo was significantly longer than ProTaper's and Hero642's, but ProTaper's and Hero642's had no significant difference. Three kinds cross-sectional design were different, a lot of toughness nests were seen in broken surface. Most of them were ductile fracture. Time to fracture was influenced by the quality disfigurement. The resistance to torque of Mtwo was better than ProTaper and Hero642. The lifespan was influenced by the design of cross-section. The quality disfigurement of the files reduced the resistance to flexual fatigue.

  13. Plans for the CIT [Compact Ignition Tokamak] instrumentation and control system

    International Nuclear Information System (INIS)

    Preckshot, G.G.

    1987-01-01

    Extensive experience with previous fusion experiments (TFTR, MFTF-B and others) is driving the design of the Instrumentation and Control System (I and C) for the Compact Ignition Tokamak (CIT) to be built at Princeton. The new design will reuse much equipment from TFTR and will be subdivided into six major parts: machine control, machine data acquisition, plasma diagnostic instrument control and instrument data acquisition, the database, shot sequencing and safety interlocks. In a major departure from previous fusion experiment control systems, the CIT machine control system will be a commercial process control system. Since the machine control system will be purchased as a completely functional product, we will be able to concentrate development manpower in plasma diagnostic instrument control, data acquisition, data processing and analysis, and database systems. We will discuss the issues driving the design, give a design overview and state the requirements upon any prospective commercial process control system

  14. Section for Standard and Patents - Standardization and Patents

    International Nuclear Information System (INIS)

    Wojtowicz, S.; Trechcinski, R.; Rybka, M.; Ryszkowska, A.; Wardaszko, J.

    1997-01-01

    Full text: The most important tasks of the Section in 1996 were: preparation of national standards and program of future work on standards for nuclear instrumentation and electronic equipment in nuclear engineering; organization of activities and participation in the meetings of the Commissions for Standardization No 173 Microprocessor Systems, No 266 Nuclear Instrumentation; giving opinions and expertises on national and international standards for equipment in nuclear engineering; cooperation with the Commission for Standardization No 246 Radiological Protection; control of inventiveness activity; The quality of the technical products is being improved by: a) selection of the proper types of interface systems, technical coordination and quality control; b) creation of standards at a high technical level; The Section works mainly for the Polish Committee for Standardization, the National Atomic Energy Agency, Association of Polish Electrical Engineers and Research Institutes in Poland. The activity of the Section is useful for all national institutions where backplane busses and nuclear electronic equipment is produced or used. The Section participates in the following international organizations: IEC (International Electrotechnical Commission) TC 45 (Nuclear Instrumentation); ISO/IEC Joint Technical Committee ISO/IEC JTCl SC26 (Microprocessor systems); ESONE (European Studies on Norms for Electronics); The section takes part in popularization of nuclear technology and instrumentation in the following ways: distribution of standards and technical documentation to national institutions dealing with nuclear apparatus; collecting and distributing technical information from international organizations (e.g. ESONE); organization of technical and scientific, national and international conferences (New Generation Nuclear Power Plants - September 96, QNX in Real World - January 96); participation in the technical conference organized by the Polish Committee for

  15. Instrumentation Needs for Integral Primary System Reactors (IPSRs) - Task 1 Final Report

    International Nuclear Information System (INIS)

    Gary D Storrick; Bojan Petrovic; Luca Oriani; Lawrence E Conway; Diego Conti

    2005-01-01

    This report presents the results of the Westinghouse work performed under Task 1 of this Financial Assistance Award and satisfies a Level 2 Milestone for the project. While most of the signals required for control of IPSRs are typical of other PWRs, the integral configuration poses some new challenges in the design or deployment of the sensors/instrumentation and, in some cases, requires completely new approaches. In response to this consideration, the overall objective of Task 1 was to establish the instrumentation needs for integral reactors, provide a review of the existing solutions where available, and, identify research and development needs to be addressed to enable successful deployment of IPSRs. The starting point for this study was to review and synthesize general characteristics of integral reactors, and then to focus on a specific design. Due to the maturity of its design and availability of design information to Westinghouse, IRIS (International Reactor Innovative and Secure) was selected for this purpose. The report is organized as follows. Section 1 is an overview. Section 2 provides background information on several representative IPSRs, including IRIS. A review of the IRIS safety features and its protection and control systems is used as a mechanism to ensure that all critical safety-related instrumentation needs are addressed in this study. Additionally, IRIS systems are compared against those of current advanced PWRs. The scope of this study is then limited to those systems where differences exist, since, otherwise, the current technology already provides an acceptable solution. Section 3 provides a detailed discussion on instrumentation needs for the representative IPSR (IRIS) with detailed qualitative and quantitative requirements summarized in the exhaustive table included as Appendix A. Section 3 also provides an evaluation of the current technology and the instrumentation used for measurement of required parameters in current PWRs. Section 4

  16. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  17. 78 FR 27186 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2013-05-09

    ... Scientific Instruments Pursuant to Section 6(c) of the Educational, Scientific and Cultural Materials...: New Mexico Institute of Mining and Technology, 801 Leroy Place, Socorro, NM 87801. Instrument: Delay... dimensions. The experiments depend on this fast 3D scanning to capture sufficient data from the dendrites of...

  18. Determination of As by instrumental neutron activation analysis in sectioned hair samples for forensic purposes: chronic or acute poisoning?

    International Nuclear Information System (INIS)

    Kucera, J.; Kofronova, K.

    2011-01-01

    Autopsy of 29-year old woman suspicious of committing suicide by the ingestion of As 2 O 3 yielded contradictory findings. All pathological findings as well as clinical symptoms suggested acute poisoning, while a highly elevated As level of 26.4 μg g -1 in her hair collected at the autopsy, which was determined with inductively coupled plasma mass spectrometry indicated chronic poisoning. To elucidate this discrepancy, instrumental neutron activation analysis (INAA) with proven accuracy was performed of another set of sectioned hair samples. Levels of As found by INAA in the range of 0.16-0.26 μg g -1 excluded chronic poisoning, because the person died after approximately 14 h after the As 2 O 3 ingestion. Two reasons for the discordant As results obtained by ICP-MS and INAA are considered: (1) accidental, non-removed contamination of hair on the As 2 O 3 ingestion; (2) erroneous performance of ICP-MS. (author)

  19. 21 CFR 864.5600 - Automated hematocrit instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated hematocrit instrument. 864.5600 Section 864.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  20. Relationship between mobility, violence and major depression among female sex workers: a cross-sectional study in southern India.

    Science.gov (United States)

    Patel, Sangram Kishor; Ganju, Deepika; Prabhakar, Parimi; Adhikary, Rajatashuvra

    2016-09-09

    The relationship between mobility, violence and mental health has largely been unexplored in developing countries. This study screens for signs of major depression, and assesses its association with mobility and violence among female sex workers (FSWs) in southern India. Data (N=2400) for this study were used from a cross-sectional Behavioral Tracking Survey (BTS-2014) conducted among FSWs from a southern state of India as part of the Avahan programme. Major depression of FSWs was assessed using the Patient Health Questionnaire-2 depression scale. Descriptive statistics, frequency, bivariate, interaction effect and multivariate logistic regression techniques were used for the analysis. More than one-fourth of FSWs (29%) screened positive for major depression. The likelihood of screening positive for major depression was 6 times higher among FSWs who were both mobile for sex work outside their district of residence and had experienced any violence (combined association) during the past 1 year (62% vs 19%, adjusted OR 6.1, 95% CI 4.4 to 8.6) compared with those who reported neither. The individual association results show that FSWs who reported being mobile outside the district, and FSWs who were beaten or raped in the past 1 year, were 3 times more likely to screen positive for major depression. The findings indicate that violence and mobility are independently associated with major depression among FSWs. The combined association of mobility and violence poses a greater risk to the mental health of FSWs than their independent association. These results point to the need for creating an enabling environment for FSWs to enhance existing efforts to reduce the spread of HIV and mental health problems. The study highlights that HIV prevention efforts among FSWs in India require evidence-based research and integrated programme approaches to address mental health issues. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted

  1. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  2. A GC Instrument Simulator

    Science.gov (United States)

    Armitage, D. Bruce

    1999-02-01

    This simulator was developed to help students beginning the study of gas chromatographic instruments to understand their operation. It is not meant to teach chromatographic theory. The instrument simulator is divided into 5 sections. One is for sample preparation. Another is used to manage carrier gases and choose a detector and column. The third sets the conditions for either isothermal or programmed temperature operation. A fourth section models manual injections, and the fifth is the autosampler. The operator has a choice among 6 columns of differing diameters and packing polarities and a choice of either isothermal or simple one-stage temperature programming. The simulator can be operated in either single-sample mode or as a 10-sample autosampler. The integrator has two modes of operation, a "dumb" mode in which only the retention time, area of the peak, and percentage area are listed and a "smart" mode that also lists the components' identities. The identities are obtained from a list of names and retention times created by the operator. Without this list only the percentages and areas are listed. The percentages are based on the areas obtained from the chromatogram and not on the actual percentages assigned during sample preparation. The data files for the compounds used in the simulator are ASCII files and can be edited easily to add more compounds than the 11 included with the simulator. A maximum of 10 components can be used in any one sample. Sample mixtures can be made on a percent-by-volume basis, but not by mass of sample per volume of solvent. A maximum of 30 compounds can be present in any one file, but the number of files is limited only by the operating system. (I suggest that not more than 20 compounds be used in any one file, as scrolling through large numbers of compounds is annoying to say the least.) File construction and layout are discussed in detail in the User's Manual. Chromatograms are generated by calculating a retention time based on

  3. Instrumentation and Controls Division biennial progress report, September 1, 1978-September 1, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Sadowski, G.S. (comp.)

    1981-06-01

    Brief summaries of research work are presented in the following section: overview of the ORNL Instrumentation and Controls Division activities; new developments and methods; reactor instrumentation and controls; measurement and control engineering; electronic engineering; maintenance; studies; services; and development; and division achievements.

  4. Instrumentation and Controls Division biennial progress report, September 1, 1978-September 1, 1980

    International Nuclear Information System (INIS)

    Sadowski, G.S.

    1981-06-01

    Brief summaries of research work are presented in the following section: overview of the ORNL Instrumentation and Controls Division activities; new developments and methods; reactor instrumentation and controls; measurement and control engineering; electronic engineering; maintenance; studies; services; and development; and division achievements

  5. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  6. Instrumentation qualification. Seismic qualification of C-E instrumentation equipment. Part One

    International Nuclear Information System (INIS)

    1977-05-01

    A summary of the C-E seismic qualification program utilized to demonstrate the seismic design adequacy of the instrumentation and control equipment used in C-E supplied Nuclear Steam Supply Systems (NSSS) is presented. The report is divided into two parts. Part One includes the equipment seismic requirements and a description of the qualification methods. Part Two lists the specific equipment by nuclear station in which it is used and the equipment test results are summarized in a standard data sheet format to facilitate review. The seismic requirements are based on individual contract commitments with C-E customers and the NRC Standard Review Plan, Section 3.10 ''Seismic Qualification of Category I Instrumentation and Electrical Equipment.'' Equipment is qualified for use in a seismic environment where damage potential to the equipment is less than or equal to that simulated seismic environment to which it has been qualified. The anticipated Safe Shutdown Earthquake (SSE) environment at the inservice location of equipment should be confirmed by each applicant as not exceeding that to which it is qualified

  7. Food Sanitation and Safety Self-assessment Instrument for Family Day-Care Homes.

    Science.gov (United States)

    1990

    This self-assessment instrument for family day care providers is designed to help caregivers provide safe food to children. The eight sections of the instrument, presented in checklist format, concern: (1) personal hygiene; (2) purchasing and inspecting of food; (3) food storage; (4) kitchen equipment; (5) food preparation; (6) infant food…

  8. [Adapting and validating the generic instrument CollaboRATE™ to measure women's participation in health related decision-making during the reproductive process].

    Science.gov (United States)

    Bravo, Paulina; Contreras, Aixa; Dois, Angelina; Villarroel, Luis

    2018-05-01

    There is a worldwide interest in involving patients in health related decisions, so patients can actively search for therapeutic options and choose course of action that allows them to have better quality of life and wellbeing. The majority of the instruments available to capture the degree of participation in medical decision-making are in English and have been developed in high income countries. To adapt and validate for the Chilean context the instrument CollaboRATE™, to measure women's participation in medical decisions during the reproductive process. Cross-sectional study to adapt and validate the instrument CollaboRATE™. Maternity units in Santiago, Chile. Puerperal women in maternity units of three public hospitals. Translation and back-translation, cultural and linguistic relevance with service users and final revision by experts. Study for validation with 90 puerperal women. The Chilean version of CollaboRATE™ demonstrated to be a reliable instrument to capture the degree of patients' participation in medical decision-making. Cronbach alpha was above 0.89. This study provides the first instrument to capture the prevalence of SDM in a Latin American country. This instrument will be critical in future research efforts that seek to explore to what extent people are being involved in the decisions related to their healthcare. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  9. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  10. Nuclear instrument maintenance and technical training in Nuclear Energy Unit

    International Nuclear Information System (INIS)

    Mohamad Nasir Abdul Wahid

    1987-01-01

    Instrument maintenance service is a necessity in a Nuclear Research Institute, such as the Nuclear Energy Unit (NEU) to ensure the smooth running of our research activities. However, realising that maintenance back-up service for either nuclear or other scientific equipment is a major problem in developing countries such as Malaysia, NEU has set up an Instrumentation and Control Department to assist in rectifying the maintenance problem. Beside supporting in house activities in NEU, the Instrumentation and Control Department (I and C) is also geared into providing services to other organisations in Malaysia. This paper will briefly outline the activities of NEU in nuclear instrument maintenance as well as in technical training. (author)

  11. The New Superfluid Helium Cryostats for the Short Straight Sections of the CERN Large Hadron Collider (LHC)

    CERN Document Server

    Cameron, W; Kurtyka, T; Parma, Vittorio; Renaglia, T; Rifflet, J M; Rohmig, P; Skoczen, Blazej; Tortschanoff, Theodor; Trilhe, P; Védrine, P; Vincent, D

    1998-01-01

    The lattice of the CERN Large Hadron Collider (LHC) contains 364 Short Straight Section (SSS) units, one in every 53 m long half-cell. An SSS consists of three major assemblies: the standard cryostat section, the cryogenic service module, and the jumper connection. The standard cryostat section of an SSS contains the twin aperture high-gradient superconducting quadrupole and two pairs of superconducting corrector magnets, operating in pressurized helium II at 1.9 K. Components for isolating cryostat insulation vacuum, and the cryogenic supply lines, have to be foreseen. Special emphasis is given to the design changes of the SSS following adoption of an external cryogenic supply line (QRL). A jumper connection connects the SSS to the QRL, linking all the cryogenic tubes necessary for the local full-cell cooling loop [at every second SSS]. The jumper is connected to one end of the standard cryostat section via the cryogenic service module, which also houses beam diagnostics, current feedthroughs, and instrument...

  12. Reboot: Revisiting Factors Influencing Female Selection of the CIS Major

    Science.gov (United States)

    Hodges, Darin; Corley, Ken

    2017-01-01

    A concern among many universities, this study reflects and continues research on the changing attitude and intent of selecting a Computer Information Systems major. Focusing on the gender gap for selection of major for women in this field, studies indicate instrumental beliefs and subjective norms can influence behavior and indicate how selection…

  13. Two Swedish screening instruments for exhaustion disorder: cross-sectional associations with burnout, work stress, private life stress, and personality traits.

    Science.gov (United States)

    Persson, Roger; Österberg, Kai; Viborg, Njördur; Jönsson, Peter; Tenenbaum, Artur

    2017-06-01

    To examine the relationships of two screening instruments recently developed for assessment of exhaustion disorder (ED) with some other well-known inventories intended to assess ED-related concepts and self-reports of job demands, job control, job support, private life stressors, and personality factors. A cross-sectional population sample ( n = 1355) completed: the Karolinska Exhaustion Disorder Scale (KEDS), Self-reported Exhaustion Disorder Scale (s-ED), Shirom-Melamed Burnout Questionnaire (SMBQ), Utrecht Work Engagement Scale (UWES-9), Job Content Questionnaire (JCQ), Big Five Inventory (BFI), and items concerning family-to-work interference and stress in private life. Compared to participants without any indication of ED, participants classified as having ED on KEDS or s-ED had higher scores on all four SMBQ subscales, lower scores on the UWES-9 subscales vigor and dedication, higher JCQ job demands scores, lower JCQ job support scores, higher degrees of family-to-work interference and stress in private life, and higher BFI neuroticism and openness scores. In addition, participants classified as having ED on KEDS had lower scores on the UWES-9 absorption subscale, the JCQ job control scale, and lower BFI extraversion, agreeableness and conscientiousness scores, compared to the subgroup not classified as having ED. As expected, we observed an overall pattern of associations between the ED screening inventories KEDS and s-ED and measures of burnout, work engagement, job demands-control-support, stress in private life, family-to-work interference, and personality factors. The results suggest that instruments designed to assess burnout, work engagement, and ED share common ground, despite their conceptual differences.

  14. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  15. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  16. Instrumentation for tomograph positioning

    International Nuclear Information System (INIS)

    Frenkel, A.D.B.; Castello Branco, L.M.; Reznik, D.S.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The COPPE's Nuclear Instrumentation Lab. has been developing researches directed towards the implementation of a Computer-Based Tomography System. Basically, the system reported in this paper can be divided into three major parts: the mechanical part, responsible for the physical movement (Stepper-Motors, table, etc.); the electronic part, which controls the mechanical part and handles the data-acquisition process (microcomputer, interfaces, etc.); and finally, the support of a software-oriented system, including control programs and information processing routines. (Author) [pt

  17. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  18. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  19. 32 CFR 37.110 - What type of instruments are technology investment agreements (TIAs)?

    Science.gov (United States)

    2010-07-01

    ... investment agreements (TIAs)? 37.110 Section 37.110 National Defense Department of Defense OFFICE OF THE... What type of instruments are technology investment agreements (TIAs)? TIAs are assistance instruments used to stimulate or support research. As discussed in appendix B to this part, a TIA may be either a...

  20. Flow karyotyping and flow instrumentation development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    GEngh, G.J. van den

    1997-11-01

    The project had three major aims: improvement of technology for high-speed cell and chromosome sorting; the use of such instrumentation in genome analysis; applying the principles developed and the lessons learned to automated processes for the genome program. The work was a continuation of studies that were started at the Lawrence Livermore National Laboratory before the PI moved to the University of Washington. At Livermore, a high-speed sorter for the selection of human chromosomes was built. The instrument incorporated Livermore`s advanced sorter technology. The engineering focused on improving robustness and reliability so that the full potential of high-speed sorting would become available to the biological research laboratory. The new instrument, dubbed MoFlo for modular flow cytometer, proved to be a very practical and efficient tool during the chromosome isolation phase of the gene-library project. Its reliability and ease of operation exceeded that of the commercial instruments. The technology was licensed to two companies.

  1. 21 CFR 892.1940 - Radiologic quality assurance instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940 Section 892.1940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance...

  2. Concurrent validation of two key health literacy instruments in a South Eastern European population.

    Science.gov (United States)

    Toçi, Ervin; Burazeri, Genc; Sørensen, Kristine; Kamberi, Haxhi; Brand, Helmut

    2015-06-01

    Public health practice has come to increasing recognition of health promotion and the central role of knowledge, attitude, beliefs and practices in achieving health promotion. Health literacy (HL) is an under-explored topic in South Eastern European countries. There are no HL reports from Albania to date. The aim of this study was to assess the concurrent validity of the European Health Literacy Survey Questionnaire (HLS-EU-Q) and the Test of Functional Health Literacy in Adults (TOFHLA) in a population-based sample of adults in Albania. A cross-sectional study was conducted in 2013 in Tirana, Albania, including 239 individuals aged ≥ 18 years (61% women; 87% response). A structured interviewer-administered questionnaire was applied twice (test and retest procedure after 2 weeks) including HLS-EU-Q and TOFHLA instruments. The internal consistency was high for both instruments (Cronbach's alpha for the test procedure was 0.92 for TOFHLA and 0.98 for HLS-EU-Q). Both tools exhibited a high stability over time (Spearman's rho: 0.88 for TOFHLA and 0.87 for HLS-EU). Mean values of both instruments were similar in men and women (mean score for TOFHLA: 76.0 vs. 76.5, P = 0.83; mean score for HLS-EU-Q: 32.2 vs. 32.6, P = 0.63). For both instruments, higher HL scores were significantly associated with younger age, higher educational and economic level and lower body mass index. Our study provides valuable novel evidence on concurrent validation of two major HL instruments in a South Eastern European population-based sample. Future studies should be conducted in order to confirm and expand our findings. © The Author 2014. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  3. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  4. Consanguinity and major genetic disorders in Saudi children: Acommunity-based cross-sectional study

    International Nuclear Information System (INIS)

    El-Mouzan, Mohammad I.; Al-Salloum, Abdullah A.; Al-Herbish, Abdullah S.; Qurachi, Mansour M.; Al-Omar, Ahmad A.

    2008-01-01

    There is a high rate of consanguinity in Saudi Arabia; however,information on its relationship with genetic disorders is limited. Theobjective of this cross-sectional study was to explore the role ofconsanguinity in genetic disorders. The study sample was determined by amultistage probability random sampling procedure. Primary care physiciansperformed a history and physical examination of all children and adolescentsyounger than 19 years and all cases of genetic diseases were recorded. Thechi-square test was used to compare proportions. During the two-year studyperiod (2004-2005), 11554 of 11874 (97%) mothers answered the question onconsanguinity and 6470 of 11554 (56%) were consanguineous. There was nosignificant association between first-cousin consanguinity and Down syndrome(P=0.55). Similarly, there was no significant association with either sicklecell disease (P=0.97) or glucose-6-phosphate dehydrogenase deficiency(P=0.67) for-cousin in consanguinity. A borderline statistical significancewas found for major congenital malformations (P=0.05). However, the mostsignificant association with first-cousin consanguinity was congenital heartdisease (CHD) (P=0.01). Finally, no significant association was found fortype 1 diabetes mellitus (P=0.92). For all types of consanguinity, similartrends of association were found, with a definite statistically significantassociation only with CHD (P=0.003). The data suggest a significant role ofparental consanguinity in CHD. However, a relationship between consanguinityand other genetic diseases could not be established. The effect ofconsanguinity on genetic diseases is not uniform and this should be takeninto consideration in genetic counseling. (author)

  5. Consideration of learning orientations as an application of achievement goals in evaluating life science majors in introductory physics

    Science.gov (United States)

    Mason, Andrew J.; Bertram, Charles A.

    2018-06-01

    When considering performing an Introductory Physics for Life Sciences course transformation for one's own institution, life science majors' achievement goals are a necessary consideration to ensure the pedagogical transformation will be effective. However, achievement goals are rarely an explicit consideration in physics education research topics such as metacognition. We investigate a sample population of 218 students in a first-semester introductory algebra-based physics course, drawn from 14 laboratory sections within six semesters of course sections, to determine the influence of achievement goals on life science majors' attitudes towards physics. Learning orientations that, respectively, pertain to mastery goals and performance goals, in addition to a learning orientation that does not report a performance goal, were recorded from students in the specific context of learning a problem-solving framework during an in-class exercise. Students' learning orientations, defined within the context of students' self-reported statements in the specific context of a problem-solving-related research-based course implementation, are compared to pre-post results on physics problem-solving items in a well-established attitudinal survey instrument, in order to establish the categories' validity. In addition, mastery-related and performance-related orientations appear to extend to overall pre-post attitudinal shifts, but not to force and motion concepts or to overall course grade, within the scope of an introductory physics course. There also appears to be differentiation regarding overall course performance within health science majors, but not within biology majors, in terms of learning orientations; however, health science majors generally appear to fare less well on all measurements in the study than do biology majors, regardless of learning orientations.

  6. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  7. Estimating discharge using multi-level velocity data from acoustic doppler instruments

    DEFF Research Database (Denmark)

    Poulsen, Jane Bang; Rasmussen, Keld Rømer; Ovesen, Niels Bering

    In the majority of Danish streams, weed growth affects the effective stream width and bed roughness thus imposes temporal variations on the stage-discharge relationship. Small stream-gradients and firm ecology based restrictions prevent that hydraulic structures are made at the discharge stations...... increases to more than 3 m. The Doppler instruments (Nortek) are placed on a vertical pole about 2 m off the right bank at three fixed elevations above the streambed (0.3, 0.6, and 1.3 m); the beams point horizontally towards the left bank perpendicularly to the average flow direction. At each depth......, the Doppler sensor records 10 minute average stream velocities in the central 10 m section of the stream. During summer periods with low flow, stream velocity has only been recorded at two depths since the water table drops below the uppermost sensor. A pressure transducer is also placed at the pole where...

  8. 7 CFR 987.104 - Major marketing promotion.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Major marketing promotion. 987.104 Section 987.104... IN RIVERSIDE COUNTY, CALIFORNIA Administrative Rules Definitions § 987.104 Major marketing promotion. A major marketing promotion program is one requiring the expenditure of more than $500 of Committee...

  9. Association of translocator protein total distribution volume with duration of untreated major depressive disorder: a cross-sectional study.

    Science.gov (United States)

    Setiawan, Elaine; Attwells, Sophia; Wilson, Alan A; Mizrahi, Romina; Rusjan, Pablo M; Miler, Laura; Xu, Cynthia; Sharma, Sarita; Kish, Stephen; Houle, Sylvain; Meyer, Jeffrey H

    2018-04-01

    People with major depressive disorder frequently exhibit increasing persistence of major depressive episodes. However, evidence for neuroprogression (ie, increasing brain pathology with longer duration of illness) is scarce. Microglial activation, which is an important component of neuroinflammation, is implicated in neuroprogression. We examined the relationship of translocator protein (TSPO) total distribution volume (V T ), a marker of microglial activation, with duration of untreated major depressive disorder, and with total illness duration and antidepressant exposure. In this cross-sectional study, we recruited participants aged 18-75 years from the Toronto area and the Centre for Addiction and Mental Health (Toronto, ON, Canada). Participants either had major depressive episodes secondary to major depressive disorder or were healthy, as confirmed with a structured clinical interview and consultation with a study psychiatrist. To be enrolled, participants with major depressive episodes had to score a minimum of 17 on the 17-item Hamilton Depression Rating Scale, and had to be medication free or taking a stable dose of medication for at least 4 weeks before PET scanning. Eligible participants were non-smokers; had no history of or concurrent alcohol or substance dependence, neurological illness, autoimmune disorder, or severe medical problems; and were free from acute medical illnesses for the previous 2 weeks before PET scanning. Participants were excluded if they had used brain stimulation treatments within the 6 months before scanning, had used anti-inflammatory drugs lasting at least 1 week within the past month, were taking hormone replacement therapy, had psychotic symptoms, had bipolar disorder (type I or II) or borderline antisocial personality disorder, or were pregnant or breastfeeding. We scanned three primary grey-matter regions of interest (prefrontal cortex, anterior cingulate cortex, and insula) and 12 additional regions and subregions using 18

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  11. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  12. Major operations and activities

    Energy Technology Data Exchange (ETDEWEB)

    Black, D.G.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the major operations and activities on the site. These operations and activities include site management, waste management, environmental restoration and corrective actions, and research and technology development.

  13. Major operations and activities

    International Nuclear Information System (INIS)

    Black, D.G.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the major operations and activities on the site. These operations and activities include site management, waste management, environmental restoration and corrective actions, and research and technology development

  14. Social relationship correlates of major depressive disorder and depressive symptoms in Switzerland: nationally representative cross sectional study.

    Science.gov (United States)

    Barger, Steven D; Messerli-Bürgy, Nadine; Barth, Jürgen

    2014-03-24

    The quality and quantity of social relationships are associated with depression but there is less evidence regarding which aspects of social relationships are most predictive. We evaluated the relative magnitude and independence of the association of four social relationship domains with major depressive disorder and depressive symptoms. We analyzed a cross-sectional telephone interview and postal survey of a probability sample of adults living in Switzerland (N=12,286). Twelve-month major depressive disorder was assessed via structured interview over the telephone using the Composite International Diagnostic Interview (CIDI). The postal survey assessed depressive symptoms as well as variables representing emotional support, tangible support, social integration, and loneliness. Each individual social relationship domain was associated with both outcome measures, but in multivariate models being lonely and perceiving unmet emotional support had the largest and most consistent associations across depression outcomes (incidence rate ratios ranging from 1.55-9.97 for loneliness and from 1.23-1.40 for unmet support, p'sdepressive symptoms whereas only loneliness and unmet support were associated with depressive disorder. Perceived quality and frequency of social relationships are associated with clinical depression and depressive symptoms across a wide adult age spectrum. This study extends prior work linking loneliness to depression by showing that a broad range of social relationship domains are associated with psychological well-being.

  15. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests

    Directory of Open Access Journals (Sweden)

    Pantaleo SCELZA

    2015-01-01

    Full Text Available The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland 25-08 and Reciproc (VDW, Munich, Germany 25-08 instruments. A total of 60 nickel-titanium (NiTi instruments (30 Reciproc and 30 WaveOne from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05. The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05. The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments’ geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  16. Instruments for measuring mental health recovery: a systematic review.

    Science.gov (United States)

    Sklar, Marisa; Groessl, Erik J; O'Connell, Maria; Davidson, Larry; Aarons, Gregory A

    2013-12-01

    Persons in recovery, providers, and policymakers alike are advocating for recovery-oriented mental health care, with the promotion of recovery becoming a prominent feature of mental health policy in the United States and internationally. One step toward creating a recovery-oriented system of care is to use recovery-oriented outcome measures. Numerous instruments have been developed to assess progress towards mental health recovery. This review identifies instruments of mental health recovery and evaluates the appropriateness of their use including their psychometric properties, ease of administration, and service-user involvement in their development. A literature search using the Medline and Psych-INFO databases was conducted, identifying 21 instruments for potential inclusion in this review, of which thirteen met inclusion criteria. Results suggest only three instruments (25%) have had their psychometric properties assessed in three or more unique samples of participants. Ease of administration varied between instruments, and for the majority of instruments, development included service user involvement. This review updates and expands previous reviews of instruments to assess mental health recovery. As mental health care continues to transform to a recovery-oriented model of service delivery, this review may facilitate selection of appropriate assessments of mental health recovery for systems to use in evaluating and improving the care they provide. © 2013.

  17. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.

    Science.gov (United States)

    Bürklein, Sebastian; Tsotsis, Polymnia; Schäfer, Edgar

    2013-04-01

    The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Reciproc and WaveOne and the full-sequence rotary Mtwo and ProTaper instruments. One group was left unprepared as control. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex and evaluated under a microscope by using 25-fold magnification. The presence of dentinal defects (complete/incomplete cracks and craze lines) was noted and analyzed by using the chi-square test. No defects were observed in the controls. All canal preparation created dentinal defects. Overall, instrumentation with Reciproc was associated with more complete cracks than the full-sequence files (P = .021). Although both reciprocating files produced more incomplete cracks apically (3 mm) compared with the rotary files (P = .001), no statistically significant differences were obtained concerning the summarized values of all cross sections (P > .05). Under the conditions of this study, root canal preparation with both rotary and reciprocating instruments resulted in dentinal defects. At the apical level of the canals, reciprocating files produced significantly more incomplete dentinal cracks than full-sequence rotary systems (P < .05). Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Differential diagnosis of bipolar disorder and major depressive disorder.

    Science.gov (United States)

    Hirschfeld, R M

    2014-12-01

    Patients with bipolar disorder spend approximately half of their lives symptomatic and the majority of that time suffering from symptoms of depression, which complicates the accurate diagnosis of bipolar disorder. Challenges in the differential diagnosis of bipolar disorder and major depressive disorder are reviewed, and the clinical utility of several screening instruments is evaluated. The estimated lifetime prevalence of major depressive disorder (i.e., unipolar depression) is over 3 and one-half times that of bipolar spectrum disorders. The clinical presentation of a major depressive episode in a bipolar disorder patient does not differ substantially from that of a patient with major depressive disorder (unipolar depression). Therefore, it is not surprising that without proper screening and comprehensive evaluation many patients with bipolar disorder may be misdiagnosed with major depressive disorder (unipolar depression). In general, antidepressants have demonstrated little or no efficacy for depressive episodes associated with bipolar disorder, and treatment guidelines recommend using antidepressants only as an adjunct to mood stabilizers for patients with bipolar disorder. Thus, correct identification of bipolar disorder among patients who present with depression is critical for providing appropriate treatment and improving patient outcomes. Clinical characteristics indicative of bipolar disorder versus major depressive disorder identified in this review are based on group differences and may not apply to each individual patient. The overview of demographic and clinical characteristics provided by this review may help medical professionals distinguish between major depressive disorder and bipolar disorder. Several validated, easily administered screening instruments are available and can greatly improve the recognition of bipolar disorder in patients with depression. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  20. Purging sensitive science instruments with nitrogen in the STS environment

    Science.gov (United States)

    Lumsden, J. M.; Noel, M. B.

    1983-01-01

    Potential contamination of extremely sensitive science instruments during prelaunch, launch, and earth orbit operations are a major concern to the Galileo and International Solar Polar Mission (ISPM) Programs. The Galileo Program is developing a system to purify Shuttle supplied nitrogen gas for in-flight purging of seven imaging and non-imaging science instruments. Monolayers of contamination deposited on critical surfaces can degrade some instrument sensitivities as much as fifty percent. The purging system provides a reliable supply of filtered and fried nitrogen gas during these critical phases of the mission when the contamination potential is highest. The Galileo and ISPM Programs are including the system as Airborne Support Equipment (ASE).

  1. Instrumental variables estimation under a structural Cox model

    DEFF Research Database (Denmark)

    Martinussen, Torben; Nørbo Sørensen, Ditte; Vansteelandt, Stijn

    2017-01-01

    Instrumental variable (IV) analysis is an increasingly popular tool for inferring the effect of an exposure on an outcome, as witnessed by the growing number of IV applications in epidemiology, for instance. The majority of IV analyses of time-to-event endpoints are, however, dominated by heurist...

  2. How is the instrumental color of meat measured?

    Science.gov (United States)

    Tapp, W N; Yancey, J W S; Apple, J K

    2011-09-01

    Peer-reviewed journal articles (n=1068) were used to gather instrumental color measurement information in meat science research. The majority of articles, published in 10 peer-reviewed journals, originated from European countries (44.8%) and North America (38.5%). The predominant species was pork (44.2%), and most researchers used Minolta (60.0%) over Hunter (31.6%) colorimeters. Much of the research was done using illuminant D65 (32.3%); nevertheless, almost half (48.9%) of the articles did not report the illuminant. Moreover, a majority of the articles did not report aperture size (73.6%) or the number of readings per sample (52.4%). Many factors influence meat color, and a considerable proportion of the peer-reviewed, published research articles failed to include information necessary to replicate and/or interpret instrumental color results; therefore, a standardized set of minimum reportable parameters for meat color evaluation should be identified. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. 47 CFR 76.51 - Major television markets.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Major television markets. 76.51 Section 76.51... CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.51 Major television markets. For purposes of the cable television rules, the following is a list of the major television markets and their...

  4. Utility of the three-dimensional reconstruction by means of helical scanography in the study of stringed instruments

    International Nuclear Information System (INIS)

    Morillo Zarate, Anibal Jose; Uriza Carrasco, Luis Felipe

    1998-01-01

    The evaluation of stringed instruments with axial computerized tomography (CT) sections has been described as a reliable method for the study of its internal components and for the detection of damaged instruments. We present the application of helical CT with thin sections and 3-D reconstructions in a series of violins, for an anatomical study of the instrument. The 3-D images offer complementary information and permit a better evaluation of the internal structure of the violin that can be useful for the understanding of the secrets of its construction and for the diagnosis of structural lesions that can affect its acoustic performance

  5. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  6. An asthma-related quality of life instrument is unable to identify asthmatic children with major psychosocial problems.

    NARCIS (Netherlands)

    Tibosch, M.M.; Reidsma, C.; Landstra, A.; Hugen, C.A.C.; Gerrits, P.; Brouwer, M.; Gent, R. van; Merkus, P.J.F.M.; Verhaak, C.M.

    2010-01-01

    Evidence shows that psychosocial problems among children and adolescents with asthma interfere with adherence to treatment and therefore need attention in asthma care. It is unknown whether the already frequently implemented asthma-related quality of life (QoL) instruments reflect psychosocial

  7. Spatial interpolation of point velocities in stream cross-section

    Directory of Open Access Journals (Sweden)

    Hasníková Eliška

    2015-03-01

    Full Text Available The most frequently used instrument for measuring velocity distribution in the cross-section of small rivers is the propeller-type current meter. Output of measuring using this instrument is point data of a tiny bulk. Spatial interpolation of measured data should produce a dense velocity profile, which is not available from the measuring itself. This paper describes the preparation of interpolation models.

  8. Affordances of Instrumentation in General Chemistry Laboratories

    Science.gov (United States)

    Sherman, Kristin Mary Daniels

    2010-01-01

    The purpose of this study is to find out what students in the first chemistry course at the undergraduate level (general chemistry for science majors) know about the affordances of instrumentation used in the general chemistry laboratory and how their knowledge develops over time. Overall, students see the PASCO(TM) system as a useful and accurate…

  9. Psychological ownership: Development of an instrument

    Directory of Open Access Journals (Sweden)

    Chantal Olckers

    2013-10-01

    Purpose: The purpose of this study was to develop an instrument to measure psychological ownership in a South African context. Motivation for the study: It was found that previous instruments for the measurement of psychological ownership lacked the ability to grasp the extensive reach of psychological ownership. Research design, approach and method: A quantitative cross-sectional survey was conducted on a non-probability convenience sample of 713 skilled, highly-skilled and professional employees from various organisations in both the private and public sectors in South Africa. Main findings: Although a 69-item measurement instrument was developed in order to capture the proposed seven-dimensional psychological ownership construct, it became evident when analysing the data that a four-factor model comprising 35 items was suitable. Practical/managerial implications: If a sense of psychological ownership toward an organisation could be established amongst its employees by addressing the factors as measured by the South African Psychological Ownership Questionnaire, organisations could become enhanced workplaces and, as a result, sustainable performance could be promoted and staff could be retained. Contribution/value-add: The instrument for measuring psychological ownership in a South African context could serve as a diagnostic tool that would allow human resource professionals and managers to determine employees’ sense of psychological ownership regarding their organisation and to focus specifically on weak dimensional areas that could be improved.

  10. Advance on solar instrumentation in China

    Science.gov (United States)

    Yan, Yihua

    2015-08-01

    The solar observing facilities in China are introduced with the emphasis on the development in recent years and future plans for both ground and space-based solar instrumentations. The recent solar instruments are as follows: A new generation Chinese Spectral Radioreliograph (CSRH) has been constructed at Mingantu Observing Station in Zhengxiangbaiqi, inner Mongolia of China since 2013 and is in test observations now. CSRH has two arrays with 40 × 4.5 m and 60 × 2 m parabolic antennas covering 0.4-2 GHz and 2-15 GHz frequency range. CSRH is renamed as MUSER (Mingantu Ultrawide Spectral Radiheliograph) after its accomplishment. A new 1 m vacuum solar telescope (NVST) has been installed in 2010 at Fuxian lake, 60 km away from Kunming, Yunana. At present it is the best seeing place in China. A new telescope called ONSET (Optical and NIR Solar Eruption Tracer) has been established at the same site as NVST in 2011. ONSET has been put into operation since 2013. For future ground-based plans, Chinese Giant Solar Telescope (CGST) with spatial resolution equivalent to 8m and effective area of 5m full-aperture telescope has been proposed and was formally listed into the National Plans of Major Science & Technology Infrastructures in China. The pre-study and site survey for CGST have been pursued. A 1-meter mid-infrared telescope for precise measurement of the solar magnetic field has been funded by NSFC in 2014 as a national major scientific instrument development project. This project will develop the first mid-infrared solar magnetic observation instrument in the world aiming at increasing the precision of the transverse magnetic field measurement by one order of magnitude. For future ground-based plans, we promote the Deep-space Solar Observatory (DSO) with 1-m aperture telescope to be formally funded. The ASO-S (an Advanced Space-based Solar Observatory) has been supported in background phase by Space Science Program as a small mission. Other related space solar

  11. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  12. Proceedings of the 1978 symposium on instrumentation and control for fossil demonstration plants

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    The 1978 symposium on instrumentation and control for fossil demonstration plants was held at Newport Beach, California, June 19--21, 1978. It was sponsored by Argonne National Laboratory, the U.S. Department of Energy - Fossil Energy, and the Instrument Society of America - Orange County Section. Thirty-nine papers have been entered individually into the data base. (LTN)

  13. 17 CFR 229.1115 - (Item 1115) Certain derivatives instruments.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false (Item 1115) Certain derivatives instruments. 229.1115 Section 229.1115 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF...

  14. Authentication of nuclear-material assays made with in-plant instruments

    International Nuclear Information System (INIS)

    Hatcher, C.R.; Hsue, S.T.; Russo, P.A.

    1982-01-01

    This paper develops a general approach for International Atomic Energy Agency (IAEA) authentication of nuclear material assays made with in-plant instruments under facility operator control. The IAEA is evaluating the use of in-plant instruments as a part of international safeguards at large bulk-handling facilities, such as reprocessing plants, fuel fabrication plants, and enrichment plants. One of the major technical problems associated with IAEA use of data from in-plant instruments is the need to show that there has been no tampering with the measurements. Two fundamentally different methods are discussed that can be used by IAEA inspectors to independently verify (or authenticate) measurements made with in-plant instruments. Method 1, called external authentication, uses a protected IAEA measurement technique to compare in-plant instrument results with IAEA results. Method 2, called internal authentication, uses protected IAEA standards, known physical constants, and special test procedures to determine the performance characteristics of the in-plant instrument. The importance of measurement control programs to detect normally expected instrument failures and procedural errors is also addressed. The paper concludes with a brief discussion of factors that should be considered by the designers of new in-plant instruments in order to facilitate IAEA authentication procedures

  15. Assessing apical transportation in curved canals: comparison between cross-sections and micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Laila Gonzales Freire

    2012-06-01

    Full Text Available The aim of this study was to compare two methods of assessing apical transportation in curved canals after rotary instrumentation, namely, cross-sections and micro-computed tomography (µCT. Thirty mandibular molars were divided into two groups and prepared according to the requirements of each method. In G1 (cross-sections, teeth were embedded in resin blocks and sectioned at 2.0, 3.5, and 5.0 mm from the anatomic apex. Pre- and postoperative sections were photographed and analyzed. In G2 (µCT, teeth were embedded in a rubber-base impression material and scanned before and after instrumentation. Mesiobuccal canals were instrumented with the Twisted File (TF system (SybronEndo, Orange, USA, and mesiolingual canals, with the EndoSequence (ES system (Brasseler, Savannah, USA. Images were reconstructed, and sections corresponding to distances 2.0, 3.5, and 5.0 mm from the anatomic apex were selected for comparison. Data were analyzed using Mann-Whitney's test at a 5% significance level. The TF and ES instruments produced little deviation from the root canal center, with no statistical difference between them (P > 0.05. The canal transportation results were significantly lower (0.056 mm in G2 than in G1 (0.089 mm (p = 0.0012. The µCT method was superior to the cross-section method, especially in view of its ability to preserve specimens and provide results that are more closely related to clinical situations.

  16. Musical instruments depicted in medieval Serbian art under oriental and western influences

    Directory of Open Access Journals (Sweden)

    Pejović Roksanda

    2005-01-01

    Full Text Available Researching musical instruments on frescoes, miniatures, icons and sculptural decorations of mediaeval Serbian art, painted and sculptured in the manner of Byzantine art, we discover Oriental and Western influences. Musical instruments arriving from the Orient were unchanged for centuries and those from West Europe were mainly used in the Middle Ages or the Renaissance. Oriental and Western influences can be observed on instruments of all families-idiophones, membranophones, bowed and string instruments, as well as on aero phones. The same form of some crotales and cymbals can be found both in Oriental and Western art, the majority of membranophones are of Oriental origin, but the tambourine on Bodani frescoes originated in West Europe. Lyres and angular harps are close to Antique tradition. Some bowed instruments, psalteries, lutes, harps, short horns, business and shawms have Oriental patterns and other instruments of these families accepted Western shapes. There are, as well, same kinds of bowed instruments and S-trumpets peculiar for both continents.

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. Design and interpretation of experiments to measure the effective removal section.

    CERN Document Server

    Desdin, L

    2001-01-01

    Paper is devoted to develop a single analytical instrument to design and interpret experiment to measure the neutron removal cross sections. There were analyzed the influence of the geometrical and nuclear parameters into the neutron removal cross sections values measured

  19. Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production.

    Science.gov (United States)

    Wada, Junichiro; Hideshima, Masayuki; Inukai, Shusuke; Matsuura, Hiroshi; Wakabayashi, Noriyuki

    2014-01-01

    To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate. © 2015 S. Karger AG, Basel.

  20. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can

  1. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  2. Social relationship correlates of major depressive disorder and depressive symptoms in Switzerland: nationally representative cross sectional study

    Science.gov (United States)

    2014-01-01

    Background The quality and quantity of social relationships are associated with depression but there is less evidence regarding which aspects of social relationships are most predictive. We evaluated the relative magnitude and independence of the association of four social relationship domains with major depressive disorder and depressive symptoms. Methods We analyzed a cross-sectional telephone interview and postal survey of a probability sample of adults living in Switzerland (N = 12,286). Twelve-month major depressive disorder was assessed via structured interview over the telephone using the Composite International Diagnostic Interview (CIDI). The postal survey assessed depressive symptoms as well as variables representing emotional support, tangible support, social integration, and loneliness. Results Each individual social relationship domain was associated with both outcome measures, but in multivariate models being lonely and perceiving unmet emotional support had the largest and most consistent associations across depression outcomes (incidence rate ratios ranging from 1.55-9.97 for loneliness and from 1.23-1.40 for unmet support, p’s social relationship domains except marital status were independently associated with depressive symptoms whereas only loneliness and unmet support were associated with depressive disorder. Conclusions Perceived quality and frequency of social relationships are associated with clinical depression and depressive symptoms across a wide adult age spectrum. This study extends prior work linking loneliness to depression by showing that a broad range of social relationship domains are associated with psychological well-being. PMID:24656048

  3. The 1997 HST Calibration Workshop with a New Generation of Instruments

    Science.gov (United States)

    Casertano, S. (Editor); Jedrzejewski, R. (Editor); Keyes, T. (Editor); Stevens, M. (Editor)

    1997-01-01

    The Second Servicing mission in early 1997 has brought major changes to the Hubble Space Telescope (HST). Two of the original instruments, Faint Object Spectrograph (FOS) and Goddard High Resolution Spectrograph (GHRS), were taken out, and replaced by completely new instruments, the Space Telescope Imaging Spectrograph (STIS) and the Near Infrared Camera Multi-Object Spectrograph (NICMOS). Two new types of detectors were installed, and for the first time, HST gained infrared capabilities. A new Fine Guidance Sensor (FGS) was installed, with an alignment mechanism that could improve substantially both guiding and astrometric capabilities. With all these changes come new challenges. The characterization of the new instruments has required a major effort, both by their respective Investigation Definition Teams and at the Space Telescope Science Institute. All necessary final calibrations for the retired spectrographs needed to be carried out, and their properties definitively characterized. At the same time, work has continued to improve our understanding of the instruments that have remained on board. The results of these activities were discussed in the 1997 HST (Hubble Space Telescope) Calibration Workshop. The main focus of the Workshop was to provide users with the tools and the understanding they need to use HST's instruments and archival data to the best of their possibilities. This book contains the written record of the Workshop. As such, it should provide a valuable tool to all interested in using existing HST data or in proposing for new observations.

  4. 26 CFR 1.1274-2 - Issue price of debt instruments to which section 1274 applies.

    Science.gov (United States)

    2010-04-01

    ... of the applicable qualified floating rate as of the date on which the sale or exchange occurs. (ii... ignored. (f) Treatment of variable rate debt instruments—(1) Stated interest at a qualified floating rate... qualified floating rate (or rates) is determined by assuming that the instrument provides for a fixed rate...

  5. Inquisitive learning as a basis for instrumental teaching: : an essay on four underpinning principles of the Prince Claus Conservatoire’s instrumental teacher education

    NARCIS (Netherlands)

    Stolte, Tine; Dons, Karolien

    2016-01-01

    Up until 2005 Peter Mak was involved as pedagogy teacher in the instrumental teacher education of the Bachelor of Music of the Prince Claus Conservatoire. The programme’s pedagogy section consisted of modules developed by Peter including ‘Didactics’, ‘Learning processes’, ‘Study skills’, and

  6. Evaluation the complex lithologies in the oil well using spectral density instrument

    International Nuclear Information System (INIS)

    Zivanov, M.; Martinovic, S.; Jakovljevic, B.

    1991-01-01

    Spectral density instrument for logging in the oil wells, beside density, measure photo electrical cross section. The principles of logging are discussed of modern spectral density. Results of logging are used dor determining the complex lithology in the oil well. With this instrument are obtained the more accurate and reliable logging results and better lithology rate and reliable logging results and better lithology determination in the formations. (author)

  7. The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments

    Directory of Open Access Journals (Sweden)

    Gianluca Gambarini

    2010-12-01

    Full Text Available The goal of the study is to evaluate if the use of rotary nickel-titanium (RNT instruments, as Hedstroem files, is safe. Twelve twisted files (TF RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments were used as control. Group B (test instruments were clinically used only as Hedstroem files in a canal that had been previously instrumented to the working length with other 06-25 RNT instruments. Group B instruments were used only in the straight portion of the canal (1 minute at 1000 rpm. A cyclic fatigue test was performed for each instrument of groups. Data were statistically analyzed (Student's t-test. Results showed no significant difference (P > 0.05 between groups A and B. Data confirmed that the use of TF instruments as Hedstroem files is a safe procedure. Cross section images and volumes of the same instrument, before and after cyclic fatigue testing, have been obtained by means of microtomographic analysis to evaluate possible microstructure alterations.

  8. Fabrication of the instrumented fuel rods for the 3-Pin Fuel Test Loop at HANARO

    International Nuclear Information System (INIS)

    Sohn, Jae Min; Park, Sung Jae; Shin, Yoon Tag; Lee, Jong Min; Ahn, Sung Ho; Kim, Soo Sung; Kim, Bong Goo; Kim, Young Ki; Lee, Ki Hong; Kim, Kwan Hyun

    2008-09-01

    The 3-Pin Fuel Test Loop(hereinafter referred to as the '3-Pin FTL') facility has been installed at HANARO(High-flux Advanced Neutron Application Reactor) and the 3-Pin FTL is under a test operation. The purpose of this report is to fabricate the instrumented fuel rods for the 3-Pin FTL. The fabrication of these fuel rods was based on experiences and technologies of the instrumented fuel rods for an irradiation fuel capsule. The three instrumented fuel rods of the 3-Pin FTL have been designed. The one fuel rod(180 .deg. ) was designed to measure the centerline temperature of the nuclear fuels and the internal pressure of the fuel rod, and others(60 .deg. and 300 .deg. ) were designed to measure the centerline temperature of the fuel pellets. The claddings were made of the reference material 1 and 2 and new material 1 and 2. And nuclear fuel was used UO 2 (2.0w/o) pellet type with large grain and standard grain. The major procedures of fabrication are followings: (1) the assembling and weld of fuel rods with the pellet mockups and the sensor mockups for the qualification tests, (2) the qualification tests(dimension measurements, tensile tests, metallography examinations and helium leak tests) of weld, (3) the assembling and weld of instrumented fuel rods with the nuclear pellets and the sensors for the irradiation test, and (4) the qualification tests(the helium leak test, the dimensional measurement, electric resistance measurements of sensors) of test fuel rods. Satisfactory results were obtained for all the qualification tests of the instrumented fuel rods for the 3-Pin FTL. Therefore the three instrumented fuel rods for the 3-Pin FTL have been fabricated successfully. These will be installed in the In-Pile Section of 3-Pin FTL. And the irradiation test of these fuel rods is planned from the early next year for about 3 years at HANARO

  9. Authentication method for safeguards instruments securing data transmission

    International Nuclear Information System (INIS)

    Richter, B.; Stein, G.; Neumann, G.; Gartner, K.J.

    1986-01-01

    Because of the worldwide increase in nuclear fuel cycle activities, the need arises to reduce inspection effort by increasing the inspection efficiency per facility. Therefore, more and more advanced safeguards instruments will be designed for automatic operation. In addition, sensoring and recording devices may be well separated from each other within the facility, while the data transmission medium is a cable. The basic problem is the authenticity of the transmitted information. It has to be ensured that no potential adversary is able to falsify the transmitted safeguards data, i.e. the data transmission is secured. At present, predominantly C/S-devices are designed for automatic and remote interrogation. Also in other areas of safeguards instrumentation authentication will become a major issue, in particular, where the facility operator may offer his process instrumentation to be used also for safeguards purposes. In this paper possibilities to solve the problem of authentication are analysed

  10. Satellite-instrument system engineering best practices and lessons

    Science.gov (United States)

    Schueler, Carl F.

    2009-08-01

    This paper focuses on system engineering development issues driving satellite remote sensing instrumentation cost and schedule. A key best practice is early assessment of mission and instrumentation requirements priorities driving performance trades among major instrumentation measurements: Radiometry, spatial field of view and image quality, and spectral performance. Key lessons include attention to technology availability and applicability to prioritized requirements, care in applying heritage, approaching fixed-price and cost-plus contracts with appropriate attention to risk, and assessing design options with attention to customer preference as well as design performance, and development cost and schedule. A key element of success either in contract competition or execution is team experience. Perhaps the most crucial aspect of success, however, is thorough requirements analysis and flowdown to specifications driving design performance with sufficient parameter margin to allow for mistakes or oversights - the province of system engineering from design inception to development, test and delivery.

  11. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  12. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    Science.gov (United States)

    Atkins, Rahshida

    2015-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis. PMID:25626225

  13. Evaluation of photonuclear reaction cross-sections using the reduction method for large systematic uncertainties

    International Nuclear Information System (INIS)

    Varlamov, V.V.; Efimkin, N.G.; Ishkhanov, B.S.; Sapunenko, V.V.

    1994-12-01

    The authors describe a method based on the reduction method for the evaluation of photonuclear reaction cross-sections obtained under conditions where there are large systematic uncertainties (different instrumental functions, calibration and normalization errors). The evaluation method involves using the actual instrumental function (photon spectrum) of each individual experiment to reduce the data to a representation generated by an instrumental function of better quality. The objective is to find the most reasonably achievable monoenergetic representation of the information on the reaction cross-section derived from the results of various experiments and to take into account the calibration and normalization errors in these experiments. The method was used to obtain the evaluated total photoneutron reaction cross-section (γ,xn) for a large number of nuclei. Data obtained for 16 O and 208 Pb are presented. (author). 36 refs, 6 figs, 4 tabs

  14. A mathematical model for describing the mechanical behaviour of root canal instruments.

    Science.gov (United States)

    Zhang, E W; Cheung, G S P; Zheng, Y F

    2011-01-01

    The purpose of this study was to establish a general mathematical model for describing the mechanical behaviour of root canal instruments by combining a theoretical analytical approach with a numerical finite-element method. Mathematical formulas representing the longitudinal (taper, helical angle and pitch) and cross-sectional configurations and area, the bending and torsional inertia, the curvature of the boundary point and the (geometry of) loading condition were derived. Torsional and bending stresses and the resultant deformation were expressed mathematically as a function of these geometric parameters, modulus of elasticity of the material and the applied load. As illustrations, three brands of NiTi endodontic files of different cross-sectional configurations (ProTaper, Hero 642, and Mani NRT) were analysed under pure torsion and pure bending situation by entering the model into a finite-element analysis package (ANSYS). Numerical results confirmed that mathematical models were a feasible method to analyse the mechanical properties and predict the stress and deformation for root canal instruments during root canal preparation. Mathematical and numerical model can be a suitable way to examine mechanical behaviours as a criterion of the instrument design and to predict the stress and strain experienced by the endodontic instruments during root canal preparation. © 2010 International Endodontic Journal.

  15. Development and Validation of a Multidimensional Expectation Questionnaire for Thalassaemia Major Patients

    OpenAIRE

    Koutelekos, Ioannis G.; Kyritsi, Helen; Makis, Alexandros; Vassalos, Constantine M; Ktenas, Eftychios; Polikandrioti, Maria; Tzoumaka-Bakoula, Chryssa; Chaliasos, Nikolaos

    2015-01-01

    Nowadays, thalassaemia major (TM) patients are surviving into mature young adulthood; however, no published instrument exists to measure the expectations? dimensionality among older TM patients in their thirties. This study seeks to validate a novel multidimensional expectation questionnaire suitable for TM patients (MEQ-TMP) reaching their fourth decade of life. In order to establish the psychometric properties of the instrument, data analysis was carried out. The principal component analysi...

  16. SOFIA science instruments: commissioning, upgrades and future opportunities

    Science.gov (United States)

    Smith, Erin C.; Miles, John W.; Helton, L. Andrew; Sankrit, Ravi; Andersson, B. G.; Becklin, Eric E.; De Buizer, James M.; Dowell, C. D.; Dunham, Edward W.; Güsten, Rolf; Harper, Doyal A.; Herter, Terry L.; Keller, Luke D.; Klein, Randolf; Krabbe, Alfred; Logsdon, Sarah; Marcum, Pamela M.; McLean, Ian S.; Reach, William T.; Richter, Matthew J.; Roellig, Thomas L.; Sandell, Göran; Savage, Maureen L.; Temi, Pasquale; Vacca, William D.; Vaillancourt, John E.; Van Cleve, Jeffrey E.; Young, Erick T.

    2014-07-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter effective aperture telescope housed in the aft section of a Boeing 747SP aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1μm imager built by Lowell Observatory; GREAT (German Receiver for Astronomy at Terahertz Frequencies), a multichannel heterodyne spectrometer from 60-240 μm, developed by a consortium led by the Max Planck Institute for Radio Astronomy; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 μm wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-200 μm IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross-Echelle Spectrograph), a 5-28 μm highresolution spectrometer designed at the University of Texas and being completed by UC Davis and NASA Ames Research Center. HAWC+ (High-resolution Airborne Wideband Camera) is a 50-240 μm imager that was originally developed at the University of Chicago as a first-generation instrument (HAWC), and is being upgraded at JPL to add polarimetry and new detectors developed at Goddard Space Flight Center (GSFC). SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details the current instrument capabilities and status, as well as the plans for future instrumentation.

  17. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  18. Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Woo-Jin Lee

    2011-05-01

    Full Text Available Objectives The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file hand file, ProFile and LightSpeed using microcomputed tomography (MCT. Materials and Methods Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1- , 2- , 3- , and 5- mm level from the apex. Data were statistically analyzed according to' repeated nested design'and Mann-Whitney test (p = 0.05. Results In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

  19. The Instrumentation Channel for the MUCOOL Experiment

    International Nuclear Information System (INIS)

    Kahn, S. A.; Guler, H.; Lu, C.; McDonald, K. T.; Prebys, E. J.; Vahsen, S. E.

    1999-01-01

    The MUCOOL facility is proposed to examine cooling techniques that could be used in a muon collider. The solenoidal beam channel before and after the cooling test section are instrumented to measure the beam emittance. This instrumentation channel includes a bent solenoid to provide dispersion and time projection chambers to measure the beam variables before and after the bend. The momentum of the muons is obtained from a measurement of the drift of the muon trajectory in the bent solenoid. The timing measurement is made by determining the phase from the momentum of the muon before and after it traverses RF cavities or by the use of a fast Cherenkov chamber. A computer simulation of the muon solenoidal channel is performed using GEANT. This study evaluates the resolution of the beam emittance measurement for MUCOOL

  20. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  1. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  3. Assessing hospitals' clinical risk management: Development of a monitoring instrument

    Directory of Open Access Journals (Sweden)

    Pfeiffer Yvonne

    2010-12-01

    Full Text Available Abstract Background Clinical risk management (CRM plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. Methods The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. Results The monitoring instrument consists of 28 main questions organized in three sections: 1 Implementation and organizational integration of CRM, 2 Strategic objectives and operational implementation of CRM at hospital level, and 3 Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian. It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. Conclusions We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  4. Assessing hospitals' clinical risk management: Development of a monitoring instrument.

    Science.gov (United States)

    Briner, Matthias; Kessler, Oliver; Pfeiffer, Yvonne; Wehner, Theo; Manser, Tanja

    2010-12-13

    Clinical risk management (CRM) plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals) was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. The monitoring instrument consists of 28 main questions organized in three sections: 1) Implementation and organizational integration of CRM, 2) Strategic objectives and operational implementation of CRM at hospital level, and 3) Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian). It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  5. Summary Report of the Technical Meeting on Inelastic Scattering and Capture Cross-section Data of Major Actinides in the Fast Neutron Region

    International Nuclear Information System (INIS)

    Plompen, Arjan; Kawano, Toshihiko; Capote Noy, Roberto

    2012-05-01

    Recently, tight target uncertainties on the capture and inelastic scattering data for major actinides were derived from advanced reactor sensitivity studies. A Technical Meeting on 'Inelastic Scattering and Capture Cross-section Data of Major Actinides in the Fast Neutron Region' was held at IAEA Headquarters, Vienna, Austria to review the status of nuclear data libraries for these cross sections, the status of the experimental results by which these can be tested and to evaluate what advances in nuclear modeling and measurement technique may bring to improve the knowledge of these cross sections. The participants compared recent evaluations with various modeling approaches that have not yet been adopted in data libraries. Several points of interest were found. First, different evaluations may show very similar performance for macroscopic benchmarks. Second, recent modeling improvements from different communities and using different codes tend to converge on the principles in the case of coupled channel calculations. In particular, it was shown that meaningful results require convergence with respect to the number of coupled channels and the use of the dispersive coupled channels potential based with an isospin dependent term to treat neutrons and protons in a coherent manner appears to be uncontested. Also, the issue regarding the use of transmission coefficients from coupled channels calculations in the Hauser Feshbach model was tackled. Recent and ongoing experimental efforts were presented for capture and inelastic scattering on the major actinides. Results from these are likely to become available in a period from 2 to 5 years. A discussion on the representation of the data in EXFOR revealed that care must be taken interpreting the numbers given in the case of inelastic scattering. It has been a long time since capture data were obtained for fissile nuclei and it is exciting to find new efforts are being considered at LANL, CERN and CENBG/IRMM. It was finally

  6. The Sound Access Parent Outcomes Instrument (SAPOI): Construction of a new instrument for children with severe multiple disabilities who use cochlear implants or hearing aids.

    Science.gov (United States)

    Hayward, Denyse V; Ritter, Kathryn; Mousavi, Amin; Vatanapour, Shabnam

    2016-01-01

    To report on the Phase 2 development of the Sound Access Parent Outcomes Instrument (SAPOI), a new instrument focused on formalizing outcomes that parents of children with severe multiple disabilities (SMD) who use amplification prioritize as important. Phase 2 of this project involved item selection and refinement of the SAPOI based on (a) Phase 1 study participant input, (b) clinical specialist feedback, and (c) test-retest instrument reliability. Phase 1 participant responses were utilized to construct a draft version of the SAPOI. Next, clinical specialists examined the instrument for content validity and utility and instrument reliability was examined through a test-retest process with parents of children with SMD. The draft SAPOI was constructed based on Phase 1 participant input. Clinical specialists supported content validity and utility of the instrument and the inclusion of 19 additional items across four categories, namely Child Affect, Child Interaction, Parent Well-being, and Child's Device Use. The SAPOI was completed twice at one-month intervals by parents of children with SMD to examine instrument reliability across the four categories (Child Affect, Child Interaction, Parent Well-being, and Child's Device Use). Instrument reliability was strong-to-excellent across all four sections. The SAPOI shows promise as a much-needed addition to the assessment battery currently used for children with SMD who use cochlear implants and hearing aids. It provides valuable information regarding outcomes resulting from access to sound in this population that currently used assessments do not identify.

  7. Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper Universal system: Histological analysis.

    Science.gov (United States)

    da Frota, Matheus Franco; Filho, Idomeo Bonetti; Berbert, Fábio Luiz Camargo Villela; Sponchiado, Emilio Carlos; Marques, André Augusto Franco; Garcia, Lucas da Fonseca Roberti

    2013-01-01

    The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.

  8. UPGRADE OF INSTRUMENTATION FOR PURDUE REACTOR PUR-1, PHASE 3

    International Nuclear Information System (INIS)

    Revankar, S. T.

    2004-01-01

    The major objective of this program is to upgrade and replace instruments and equipment that significantly improve the performance, control and operational capability of the Purdue University nuclear reactor (PUR-1). Under this major objective one project on design and installation of interface cards for channel four detector was considered. This report is the final report and gives the efforts and progress achieved on these projects from August 2002 to July 2004

  9. A rating instrument for fear of hospitalisation.

    Science.gov (United States)

    Jankovic, Slobodan M; Antonijevic, Gordana V; Vasic, Ivana R; Zivkovic-Radojevic, Marija N; Mirkovic, Snjezana N; Nikolic, Bosko V; Opancina, Valentina D; Putnik, Srdjan S; Radoicic, Ljiljana R; Raspopovic, Katarina M; Stanojevic, Dragan R; Teofilov, Sladjana D; Tomasevic, Katarina V; Radonjic, Vesela

    2018-04-01

    To develop and validate a reliable instrument that can measure fear of hospitalisation experienced by outpatients. After having a diagnosis established, some patients experience sense of fear, unpleasantness and embarrassment due to the possibility to be admitted to a hospital. Currently, there is no available instrument for measuring fear of hospitalisation. Cross-sectional study for assessing reliability and validity of a questionnaire. The questionnaire with 17 items and answers according to the Likert scale was developed during two brainstorming sessions of the research team. Its reliability, validity and temporal stability were tested on the sample of 330 outpatients. The study was multicentric, involving patients from seven cities and three countries. Fear of hospitalisation scale showed satisfactory reliability, when rated both by the investigators (Cronbach's alpha .799) and by the patients themselves (Cronbach's alpha .760). It is temporally stable, and both divergent and convergent validity tests had good results. Factorial analysis revealed three domains: fear of being injured, trust to medical staff and fear of losing privacy or autonomy. This study developed new reliable and valid instrument for measuring fear of hospitalisation. Identification of patients with high level of fear of hospitalisation by this instrument should help clinicians to administer measures which may decrease fear and prevent avoidance of healthcare utilisation. © 2018 John Wiley & Sons Ltd.

  10. Measurement of arsenic in sectioned hair samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.; Gavrilas-Guinn, M.; Demiralp, R.

    1994-01-01

    In a recent Texas murder case, bundles of head hair from the female victim (aligned with all root ends together) were washed, cut into 7 mm sections, air-dried and weighed, activated in a nuclear reactor neutron flux, and then counted with a Ge(Li) detector/4096-channel gamma-ray spectrometer. In each of the 15 samples, the 559 keV gamma-ray peak of 26.3 hour 76 As was measured. In the section closest to the scalp, an arsenic concentration of 107 ppm was found (cf. a 'normal' level of about 1 ppm As). Barium ingestion was also possible so Ba was looked for, but not found. The victim's husband was found guilty of murder by chronic arsenic poisoning. (author) 2 refs.; 1 fig.; 1 tab

  11. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  12. Major plant retrofits at Monticello nuclear generating plant

    International Nuclear Information System (INIS)

    Larsen, D.E.; Hogg, C.B.

    1986-01-01

    For the past several years, Northern States Power (NSP) has been making major plant retrofits to Monticello Nuclear generating Station in order to improve plant availability and upgrade the plant components for the potential extension of the operating license (life extension). This paper discusses in detail three major retrofits that have been completed or in the process of completion; recirculation loop piping replacement, reactor pressure vessel (RPV) water level-instrumentation modification, core spray piping replacement, the authors will address the scope of work, design and installation concerns, and life extension considerations during the design and procurement process for these three projects

  13. Validation of Yoon's Critical Thinking Disposition Instrument.

    Science.gov (United States)

    Shin, Hyunsook; Park, Chang Gi; Kim, Hyojin

    2015-12-01

    The lack of reliable and valid evaluation tools targeting Korean nursing students' critical thinking (CT) abilities has been reported as one of the barriers to instructing and evaluating students in undergraduate programs. Yoon's Critical Thinking Disposition (YCTD) instrument was developed for Korean nursing students, but few studies have assessed its validity. This study aimed to validate the YCTD. Specifically, the YCTD was assessed to identify its cross-sectional and longitudinal measurement invariance. This was a validation study in which a cross-sectional and longitudinal (prenursing and postnursing practicum) survey was used to validate the YCTD using 345 nursing students at three universities in Seoul, Korea. The participants' CT abilities were assessed using the YCTD before and after completing an established pediatric nursing practicum. The validity of the YCTD was estimated and then group invariance test using multigroup confirmatory factor analysis was performed to confirm the measurement compatibility of multigroups. A test of the seven-factor model showed that the YCTD demonstrated good construct validity. Multigroup confirmatory factor analysis findings for the measurement invariance suggested that this model structure demonstrated strong invariance between groups (i.e., configural, factor loading, and intercept combined) but weak invariance within a group (i.e., configural and factor loading combined). In general, traditional methods for assessing instrument validity have been less than thorough. In this study, multigroup confirmatory factor analysis using cross-sectional and longitudinal measurement data allowed validation of the YCTD. This study concluded that the YCTD can be used for evaluating Korean nursing students' CT abilities. Copyright © 2015. Published by Elsevier B.V.

  14. A new method based on low background instrumental neutron activation analysis for major, trace and ultra-trace element determination in atmospheric mineral dust from polar ice cores

    Energy Technology Data Exchange (ETDEWEB)

    Baccolo, Giovanni, E-mail: giovanni.baccolo@mib.infn.it [Graduate School in Polar Sciences, University of Siena, Via Laterina 8, 53100, Siena (Italy); Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Clemenza, Massimiliano [INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Department of Physics, University of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Delmonte, Barbara [Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); Maffezzoli, Niccolò [Centre for Ice and Climate, Niels Bohr Institute, Juliane Maries Vej, 30, 2100, Copenhagen (Denmark); Nastasi, Massimiliano; Previtali, Ezio [INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Department of Physics, University of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Prata, Michele; Salvini, Andrea [LENA, University of Pavia, Pavia (Italy); Maggi, Valter [Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy)

    2016-05-30

    Dust found in polar ice core samples present extremely low concentrations, in addition the availability of such samples is usually strictly limited. For these reasons the chemical and physical analysis of polar ice cores is an analytical challenge. In this work a new method based on low background instrumental neutron activation analysis (LB-INAA) for the multi-elemental characterization of the insoluble fraction of dust from polar ice cores is presented. Thanks to an accurate selection of the most proper materials and procedures it was possible to reach unprecedented analytical performances, suitable for ice core analyses. The method was applied to Antarctic ice core samples. Five samples of atmospheric dust (μg size) from ice sections of the Antarctic Talos Dome ice core were prepared and analyzed. A set of 37 elements was quantified, spanning from all the major elements (Na, Mg, Al, Si, K, Ca, Ti, Mn and Fe) to trace ones, including 10 (La, Ce, Nd, Sm, Eu, Tb, Ho, Tm, Yb and Lu) of the 14 natural occurring lanthanides. The detection limits are in the range of 10{sup −13}–10{sup −6} g, improving previous results of 1–3 orders of magnitude depending on the element; uncertainties lies between 4% and 60%. - Highlights: • A new method based on neutron activation for the multi-elemental characterization of atmospheric dust entrapped in polar ice cores is proposed. • 37 elements were quantified in μg size dust samples with detection limits ranging from 10{sup −13} to 10{sup −6} g. • A low background approach and a clean analytical protocol improved INAA performances to unprecedented levels for multi-elemental analyses.

  15. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  16. The quality of instruments to assess the process of shared decision making: A systematic review

    Science.gov (United States)

    Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.

    2018-01-01

    Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of

  17. An Ethic of Care in High School Instrumental Music

    Science.gov (United States)

    Edgar, Scott N.

    2014-01-01

    The purpose of this paper is to apply Noddings' ethic of care to a qualitative inquiry of select instrumental music educators. In the first section I describe and define an ethic of care, considering specifically who is involved in a caring relationship, how an ethic of care can be taught, and strategies for educational implementation and…

  18. 17 CFR 1.28 - Appraisal of instruments purchased with customer funds.

    Science.gov (United States)

    2010-04-01

    ... purchased with customer funds. 1.28 Section 1.28 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION GENERAL REGULATIONS UNDER THE COMMODITY EXCHANGE ACT Customers' Money, Securities, and Property § 1.28 Appraisal of instruments purchased with customer funds. Futures commission merchants who...

  19. Design of in-pile section monitoring system in fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Sim, B. S.; Park, K. N.; Park, S. K.; Chi, D. Y.; Lee, J. M.; Ahn, S. H.; Lee, C. Y.; Kim, Y. J. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2005-07-01

    In this paper a brief summary of the monitoring system of In-Pile Section(IPS) is described. To meet the user requirements on the test fuel and irradiation conditions, various instruments are installed on the test fuel pin itself and the appropriate locations in IPS. The requirements and descriptions for instruments, gas supply system, and the data acquisition system to sample and record parameters are described.

  20. Assessment of cognitive function in children with beta-thalassemia major: a cross-sectional study.

    Science.gov (United States)

    Raafat, Nelly; El Safy, Usama; Khater, Nahed; Hassan, Tamer; Hassan, Basheir; Siam, Ahmed; Youssef, Amira; El Shabrawy, Amany

    2015-03-01

    Multiple risk factors contribute to cognitive impairment in children with β-thalassemia major. For a more refined understanding of this issue, we attempted to evaluate cognitive function in β-thalassemia major patients and identify the relationship between possible cognitive dysfunction and the following: demography, transfusion and chelation characteristics, iron overload, and disease complications. We studied 100 β-thalassemia major children and 100 healthy controls who matched well in terms of age, sex, and socioeconomic status. All participants underwent psychometric assessment using Wechsler Intelligence Scale for Children-Third Edition, Arabic version. The mean Full-Scale IQ and Performance IQ of patients were significantly lower than those of controls, whereas no significant difference was found for Verbal IQ. No significant relationship existed between IQ and any of the assessed parameters. We concluded that Performance IQ, not Verbal IQ, was significantly affected in β-thalassemia major patients, but there was no clear association between IQ and any of the parameters. © The Author(s) 2014.

  1. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  2. LAMMA 500 principle and technical description of the instrument

    International Nuclear Information System (INIS)

    Vogt, H.; Heinen, H.J.; Meier, S.; Wechsung, R.

    1981-01-01

    The Laser Microprobe Mass Analyzer LAMMA 500 originally had been designed for the analysis of biomedical samples, especially thin sections, with high lateral resolution and extreme detection sensitivity. The principle of LAMMA is based on the excitation of a microvolume of the sample to an ionized state by a focused laser beam. The analytical information is derived from mass spectrometry of these ions. It is obvious that all elements of the periodic table and their isotopes can be detected. Various applications have demonstrated that besides element detection the instrument can also be used for the detection of organic and inorganic compounds. A detailed description of the LAMMA 500 instrument is given. (orig./RB)

  3. The Construct Validity of an Instrument for Measuring Type 2 ...

    African Journals Online (AJOL)

    Abstract. Purpose: To develop an instrument (DSCKQ-30) for measuring type 2 diabetic patients' knowledge of self-care practices. Methods: A 30-item questionnaire (DSCKQ-30) consisting of close ended questions was developed for this study. DSCKQ-30 was self administered to a cross-section of randomly selected 400 ...

  4. Surgical Instrument Sets for Special Operations Expeditionary Surgical Teams.

    Science.gov (United States)

    Hale, Diane F; Sexton, Justin C; Benavides, Linda C; Benavides, Jerry M; Lundy, Jonathan B

    The deployment of surgical assets has been driven by mission demands throughout years of military operations in Iraq and Afghanistan. The transition to the highly expeditious Golden Hour Offset Surgical Transport Team (GHOST- T) now offers highly mobile surgical assets in nontraditional operating rooms; the content of the surgical instrument sets has also transformed to accommodate this change. The 102nd Forward Surgical Team (FST) was attached to Special Operations assigned to southern Afghanistan from June 2015 to March 2016. The focus was to decrease overall size and weight of FST instrument sets without decreasing surgical capability of the GHOST-T. Each instrument set was evaluated and modified to include essential instruments to perform damage control surgery. The overall number of main instrument sets was decreased from eight to four; simplified augmentation sets have been added, which expand the capabilities of any main set. The overall size was decreased by 40% and overall weight decreased by 58%. The cardiothoracic, thoracotomy, and emergency thoracotomy trays were condensed to thoracic set. The orthopedic and amputation sets were replaced with an augmentation set of a prepackaged orthopedic external fixator set). An augmentation set to the major or minor basic sets, specifically for vascular injuries, was created. Through the reorganization of conventional FST surgical instrument sets to maintain damage control capabilities and mobility, the 102nd GHOST-T reduced surgical equipment volume and weight, providing a lesson learned for future surgical teams operating in austere environments. 2017.

  5. The NSTX Central Instrumentation and Control System

    International Nuclear Information System (INIS)

    G. Oliaro; J. Dong; K. Tindall; P. Sichta

    1999-01-01

    Earlier this year the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory achieved ''first plasma''. The Central Instrumentation and Control System was used to support plasma operations. Major elements of the system include the Process Control System, Plasma Control System, Network System, Data Acquisition System, and Synchronization System. This paper will focus on the Process Control System. Topics include the architecture, hardware interface, operator interface, data management, and system performance

  6. Histological analysis of cleaning efficacy of hand and rotary instruments in the apical third of the root canal: A comparative study.

    Science.gov (United States)

    Arya, Ashtha; Bali, Dildeep; Grewal, Mandeep S

    2011-07-01

    To compare the cleaning efficiency of manual and rotary instrumentation in the apical third of the root canal system. In group 1 (n=10), instrumentation was performed with stainless steel K-file; in group 2 (n=10), it was done with hand ProTaper files; and in group 3 (n=10), instrumentation was done with ProTaper rotary. Distilled water was used for irrigation. The apical third was sectioned transversally and histologically processed. The cross sections were examined under optic microscope and debris was measured using Motic software. Instrumentation with stainless steel K-files showed minimum amount of debris, followed by ProTaper hand files, and rotary ProTaper files were least effective with maximum amount of debris; however, there were no significant differences between the three experimental groups. Both the manual and rotary instrumentation are relatively efficient in cleaning the apical third of the root canal system and the choice between manual and rotary instrumentation should depend on case to case basis.

  7. Governing towards renewable energy in the EU: competences, instruments and procedures

    NARCIS (Netherlands)

    Peeters, M.G.W.M.

    2014-01-01

    ABSTRACT Th is contribution maps new questions and explores potential problems in EU renewable energy law, focusing on competences, regulatory instruments and administrative procedures. The transition towards renewable energy concerns a major transformation of society, which cannot be done on a

  8. 17 CFR 1.26 - Deposit of instruments purchased with customer funds.

    Science.gov (United States)

    2010-04-01

    ... purchased with customer funds. 1.26 Section 1.26 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION GENERAL REGULATIONS UNDER THE COMMODITY EXCHANGE ACT Customers' Money, Securities, and Property § 1.26 Deposit of instruments purchased with customer funds. (a) Each futures commission merchant...

  9. Residential greenness and prevalence of major depressive disorders: a cross-sectional, observational, associational study of 94 879 adult UK Biobank participants

    Directory of Open Access Journals (Sweden)

    Chinmoy Sarkar, PhD

    2018-04-01

    Full Text Available Summary: Background: Increased urbanisation and the associated reduced contact of individuals with natural environments have led to a rise in mental disorders, including depression. Residential greenness, a fundamental component of urban design, has been shown to reduce the public health burden of mental disorders. The present study investigates the association between residential green exposure and prevalence of major depressive disorders using a large and diverse cross-sectional dataset from the UK Biobank. Methods: In this cross-sectional, observational, associational study, we used baseline data from the UK Biobank cohort of participants aged 37–73 years from across the UK. Environmental exposure data were derived from a modelled and linked built environment database. Residential greenness was assessed with a 0·5 m resolution Normalised Difference Vegetation Index, which is derived from spectral reflectance measurements in remotely sensed colour infrared data and measured within geocoded dwelling catchments. Other environment metrics included street-level movement density, terrain, and fine particulate exposures. A series of logistic models examined associations between residential greenness and odds of major depressive disorder after adjusting for activity-influencing environments and individual covariates. Findings: Of 122 993 participants with data on major depressive disorder, the study analytical sample comprised 94 879 (77·1% participants recruited across ten UK Biobank assessment centres between April 29, 2009, and Oct 1, 2010. A protective effect of greenness on depression was consistently observed, with 4·0% lower odds of major depressive disorder per interquartile increment in Normalised Difference Vegetation Index greenness (odds ratio 0·960, 95% CI 0·93–0·99; p=0·0044. Interaction analyses indicated that the beneficial effects of greenness were more pronounced among women, participants younger than 60 years, and

  10. Comparative Study of Three Rotary Instruments for root canal Preparation using Computed Tomography

    International Nuclear Information System (INIS)

    Mohamed, A.M.E.

    2015-01-01

    Cleaning and shaping the root canal is a key to success in root canal treatment. This includes the removal of organic substrate from the root canal system by chemo mechanical methods, and the shaping of the root canal system into a continuously tapered preparation. This should be done while maintaining the original path of the root canal. Although instruments for root canal preparation have been progressively developed and optimized, a complete mechanical debridement of the root canal system is rarely achievable. One of the main reasons is the geometrical dis symmetry between the root canal and preparation instruments. Rotary instruments regardless of their type and form produce a preparation with a round outline if they are used in a simple linear filing motion, which in most of the cases do not coincide with the outline of the root canal. Root canal preparation in narrow, curved canals is a challenge even for experienced endodontists. Shaping of curved canals became more effective after the introduction of nickel-titanium (Ni-Ti) endodontic instruments. Despite the advantages of Ni-Ti rotary instruments, intra canal fracture is the most common procedural accident that occurs with these instruments during clinical use. It is a common experience between clinicians that Ni-Ti rotary instruments may undergo unexpected fracture without any visible warning, such as any previous permanent defect or deformation. Pro Taper Ni-Ti instruments were introduced with a unique design of variable taper within one instrument and continuously changing helical angles. Pro Taper rotary instruments are claimed to generate lower torque values during their use because of their modified nonradial landed cross-section that increases the cutting efficiency and reduces contact areas. On the other hand, the variable taper within one instrument is believed to reduce the ‘taper lock’ effect (torsional failure) in comparison with similarly tapered instruments. Nevertheless, Pro Taper

  11. Pulse Wave Velocity Measuring System using Virtual Instrumentation on Mobile Device

    Directory of Open Access Journals (Sweden)

    Razvan Alin Ciobotariu

    2013-03-01

    Full Text Available Virtual instrumentation is a concept that permits customizable modular software measurement and the development of the user-defined tools for control, process and visualization of data, creating versatile systems, using modular programming, intuitive and easy to use. In this paper we investigate a possibility of using virtual instrumentation in the development of two physiological parameters monitoring system, in order to assess a cardiovascular parameter, the Pulse Wave Velocity (PWV. We choose to monitor this parameter due to major incidence and impact of cardiovascular diseases (CVD.

  12. Optimization criteria for control and instrumentation systems in nuclear power plants

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    1978-01-01

    The system of dose limitation recently recommended by the International Commission on Radiation Protection includes, as a base for deciding what is reasonably achievable in dose reduction, the optimization of radioprotection systems. This paper, after compiling relevant points in the new system, discusses the application of optimization to control and instrumentation of radioprotection systems in nuclear power plants. Furthermore, an extension of the optimization criterion to nuclear safety systems is also presented and its application to control and instrumentation is discussed; systems including majority logics are particularly scrutinized. Finally, eventual regulatory implications are described. (author)

  13. Analysis of in-core coolant temperatures of FFTF instrumented fuels tests at full power

    International Nuclear Information System (INIS)

    Hoth, C.W.

    1981-01-01

    Two full size highly instrumented fuel assemblies were inserted into the core of the Fast Flux Test Facility in December of 1979. The major objectives of these instrumented tests are to provide verification of the FFTF core conditions and to characterize temperature patterns within FFTF driver fuel assemblies. A review is presented of the results obtained during the power ascents and during irradiation at a constant reactor power of 400 MWt. The results obtained from these instrumented tests verify the conservative nature of the design methods used to establish core conditions in FFTF. The success of these tests also demonstrates the ability to design, fabricate, install and irradiate complex, instrumented fuel tests in FFTF using commercially procured components

  14. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    radioactive shipment. Response summaries in the form of a pass/fail listing for isotope identification for each of the three classes of gamma emitters (SNM, medical, and industrial) were recorded. Each instrument was then tested for response to the neutron source, Cf-252, a spontaneous fission isotope. Each instrument's ability to identify several pairs of isotopes was determined. This test was intended to verify if the instrument could detect SNM when accompanied by a masking isotope. Finally, each instrument's dose rate response to different energy gamma emitters was measured. One section of this test was conducted at a very low exposure rate, 10 microR/hr above background, and the second section conducted at 2 mR/hr above background. The latter dose rate represented the expected maximum exposure rate for a properly packaged medical isotope shipment. A third dose rate, 200mR/hr, was also used. Tests also were conducted to determine the instrument's display visibility, audio alarms, and operational characteristics in electromagnetic fields and high humidity conditions. (author)

  15. 76 FR 39234 - Federal Acquisition Regulation; Unique Procurement Instrument Identifier

    Science.gov (United States)

    2011-07-05

    ..., therefore, was not subject to review under section 6(b) of E.O. 12866, Regulatory Planning and Review, dated... for procurement actions, such as delivery and task orders or basic ordering agreements, the order or... Instrument Identifier (PIID). Agencies shall have in place a process that ensures that each PIID reported to...

  16. Toward Development of a Generalized Instrument to Measure Andragogy

    Science.gov (United States)

    Holton, Elwood F., III; Wilson, Lynda Swanson; Bates, Reid A.

    2009-01-01

    Andragogy has emerged as one of the dominant frameworks for teaching adults during the past 40 years. A major and glaring gap in andragogy research is the lack of a measurement instrument that adequately measures both andragogical principles and process design elements. As a result, no definitive empirical test of the theory has been possible. The…

  17. Machine and plasma diagnostic instrumentation systems for the Tandem Mirror Experiment Upgrade

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Lang, D.D.; Hornady, R.S.

    1981-01-01

    To evaluate performance of a second generation Tandem Mirror Machine, an extensive instrumentation system is being designed and installed as part of the major device fabrication. The systems listed will be operational during the start-up phase of the TMX Upgrade machine and provide bench marks for future performance data. In addition to plasma diagnostic instrumentation, machine parameter monitoring systems will be installed prior to machine operation. Simultaneous recording of machine parameters will permit evaluation of plasma parameters sensitive to machine conditions

  18. Instrumentation and Controls Division, Technical Support Department Management Plan, FY 1993--FY 1996

    Energy Technology Data Exchange (ETDEWEB)

    Adkisson, B.P.; Kunselman, C.W.; Effler, R.P.; Miller, D.R.; Millet, A.J.; Stansberry, C.T.

    1993-08-01

    This report describes the organization, key functions, and major activities of the Technical Support Department The Department is the programmatic support element of the Instrumentation and Controls Division. The Department`s primary focus is the support of existing equipment and systems at Oak Ridge National Laboratory that are generally characterized as instrumentation and controls. The support takes the form of repair, calibration, fabrication, field engineering, preventive maintenance, software support, and record keeping.

  19. Instrumentation in high energy physics

    International Nuclear Information System (INIS)

    Serin, L.

    2007-01-01

    The instrumentation in high energy physics is a wide and advanced domain which cannot be covered in a single lesson. The main basic physics processes for charged and neutral particles are recalled with the definition of a few concepts needed to understand or design a detector. The application of these principles to charged particle measurement devices (momentum), light detection or energy measurement are presented mostly with examples from collider experiments. The particle identification which is often the combination of different techniques in a same experiment is also discussed. Finally in a very short section, a few considerations about electronics/processing with their impact on the detector performance are given

  20. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    Science.gov (United States)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  1. Investigation on Motorcyclist Riding Behaviour at Curve Entry Using Instrumented Motorcycle

    Science.gov (United States)

    Yuen, Choon Wah; Karim, Mohamed Rehan; Saifizul, Ahmad

    2014-01-01

    This paper details the study on the changes in riding behaviour, such as changes in speed as well as the brake force and throttle force applied, when motorcyclists ride over a curve section road using an instrumented motorcycle. In this study, an instrumented motorcycle equipped with various types of sensors, on-board cameras, and data loggers, was developed in order to collect the riding data on the study site. Results from the statistical analysis showed that riding characteristics, such as changes in speed, brake force, and throttle force applied, are influenced by the distance from the curve entry, riding experience, and travel mileage of the riders. A structural equation modeling was used to study the impact of these variables on the change of riding behaviour in curve entry section. Four regression equations are formed to study the relationship between four dependent variables, which are speed, throttle force, front brake force, and rear brake force applied with the independent variables. PMID:24523660

  2. Evaluation of surface characteristics of rotary nickel-titanium instruments produced by different manufacturing methods.

    Science.gov (United States)

    Inan, U; Gurel, M

    2017-02-01

    Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).

  3. Nuclear instrument engineering - the measuring and informative basis of nuclear science and technology

    International Nuclear Information System (INIS)

    Matveev, V.V.; Krasheninnikov, I.S.; Murin, I.D.; Stas', K.N.

    1977-01-01

    The cornerstones of developing nuclear instrument engineering in the USSR are shortly discussed. The industry is based on a well developed theory. A system approach is a characteristic feature of the present-day measuring and control systems engineering. Major functions of reactor instruments measuring different types of ionizing radiation are discussed at greater length. Nuclear measuring and control instruments and methods are widely used in different fields of science and technoloay and in different industries in the USSR. The efficient and safe operation of a nuclear facility is underlined to depend strongly upon a correlation between a technological process and the information and control system of the facility

  4. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  5. Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-01-01

    Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 - 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.

  6. High degree modes and instrumental effects

    Energy Technology Data Exchange (ETDEWEB)

    Korzennik, S G [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Rabello-Soares, M C; Schou, J [Stanford University, Stanford, CA (United States)], E-mail: skorzennik@cfa.harvard.edu

    2008-10-15

    Full-disk observations taken with the Michelson Doppler Imager (MDI) on board the Solar and Heliospheric Observatory (SOHO) spacecraft, or the upgraded Global Oscillations Network Group (GONG) instruments, have enough spatial resolution to resolve modes up to {iota} = 1000 if not {iota} = 1500. The inclusion of such high-degree modes (i.e., {iota} {<=} 1000) improves dramatically inferences near the surface. Unfortunately, observational and instrumental effects cause the characterization of high degree modes to be quite complicated. Indeed, the characteristics of the solar acoustic spectrum are such that, for a given order, mode lifetimes get shorter and spatial leaks get closer in frequency as the degree of a mode increases. A direct consequence of this property is that individual modes are resolved only at low and intermediate degrees. At high degrees the individual modes blend into ridges and the power distribution of the ridge defines the ridge central frequency, masking the underlying mode frequency. An accurate model of the amplitude of the peaks that contribute to the ridge power distribution is needed to recover the underlying mode frequency from fitting the ridge. We present a detailed discussion of the modeling of the ridge power distribution, and the contribution of the various observational and instrumental effects on the spatial leakage, in the context of the MDI instrument. We have constructed a physically motivated model (rather than an ad hoc correction scheme) that results in a methodology that can produce unbiased estimates of high-degree modes. This requires that the instrumental characteristics are well understood, a task that has turned out to pose a major challenge. We also present our latest results, where most of the known instrumental and observational effects that affect specifically high-degree modes were removed. These new results allow us to focus our attention on changes with solar activity. Finally, we present variations of mode

  7. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    Science.gov (United States)

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  8. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  9. Complication of cesarean section: pregnancy on the cicatrix of a previous cesarean section.

    Science.gov (United States)

    Wang, Weimin; Long, Wenqing; Yu, Qunhuan

    2002-02-01

    To probe into the clinical manifestation, diagnosis, as well as treatment of pregnancy on the cicatrix of a previous cesarean section at the uterine isthmus in the first trimester. Analysis of 14 patients with pregnancy on the cicatrix of a previous cesarean section at the uterine isthmus in the first trimester was made after conservative treatment by drugs from January 1996 to December 1999. The 14 patients with a pregnancy on the cicatrix of a previous cesarean section at the uterine isthmus in the first trimester were painless, had slight vaginal bleeding, and concurrently had increased serum beta-subunit human chorionic gonadotropin (beta-HCG). Doppler ultrasonic examination revealed an obvious enlargement of the previous cesarean section cicatrix in the uterine isthmus, and found a gestational sac or mixed mass attached to the cicatrice, with a very thin myometrium between the gestational sac and bladder walls. Among the 14 patients, 12 patients had crystalline trichosanthes injected into the cervix, mifepristone taken orally, or methotrexate in the form of intramuscular injection. Following this procedure, their serum beta-HCG dropped to normal. The other 2 patients had a total hysterectomy. Pregnancy on the cicatrix of a previous cesarean section at the uterine isthmus in the first trimester is a complication of cesarean section. Early diagnosis and effective conservative treatment by drugs are instrumental in decreasing the potential occurrence of uterine rupture, which is also conducive to preserving the patient's future fertility.

  10. Frequency of instrumental vaginal delivery in patients with and without receiving epidural analgesia

    International Nuclear Information System (INIS)

    Phool, B.

    2013-01-01

    Aims and Objectives: Frequency of instrumental vaginal delivery in women receiving epidural analgesia and those who are not receiving.Study Design: It was a cohort study. Duration: 6th month. Results: Majority of the patients were found between 20 - 25 years of age in both A and B groups, in Group - A 46.11% (n = 83) and in Group - B 52.22% (n = 94), mean and standard deviation was calculated 26.21 +- 3.56 in Group - A and 27.34 +- 3.78 in Group - B, comparison of instrumental vaginal delivery reveals 10.55% (n = 19) in Group - A were with instrumental delivery while in Group - B only 2.78% (n = 5) cases were found delivered with instruments.Conclusion: Epidural analgesia is considered to be an effective method of pain relief during labor but due to the higher risk of increased duration of 2nd stage of labour it increases the possibility of instrumental delivery. (author)

  11. 40 CFR 65.104 - Instrument and sensory monitoring for leaks.

    Science.gov (United States)

    2010-07-01

    ... the representative composition of the process fluid not each individual organic compound in the stream...)(ii) of this section. (i) Mixtures of methane in air at a concentration no more than 2,000 parts per... calibration gas other than methane in air may be used if the instrument does not respond to methane or if the...

  12. Instrumental vaginal delivery - an assessment of use in a tertiary ...

    African Journals Online (AJOL)

    Background: Majority of women in sub-Saharan Africa expect to achieve spontaneous vaginal delivery at the end of pregnancy. This is usually possible, but, a few women will receive one form of assistance or another (forceps or vacuum) to avert maternal or foetal morbidity or mortality. Training and research in instrumental ...

  13. The Characterization of Biosignatures in Caves Using an Instrument Suite

    Science.gov (United States)

    Uckert, Kyle; Chanover, Nancy J.; Getty, Stephanie; Voelz, David G.; Brinckerhoff, William B.; McMillan, Nancy; Xiao, Xifeng; Boston, Penelope J.; Li, Xiang; McAdam, Amy; Glenar, David A.; Chavez, Arriana

    2017-12-01

    The search for life and habitable environments on other Solar System bodies is a major motivator for planetary exploration. Due to the difficulty and significance of detecting extant or extinct extraterrestrial life in situ, several independent measurements from multiple instrument techniques will bolster the community's confidence in making any such claim. We demonstrate the detection of subsurface biosignatures using a suite of instrument techniques including IR reflectance spectroscopy, laser-induced breakdown spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy. We focus our measurements on subterranean calcium carbonate field samples, whose biosignatures are analogous to those that might be expected on some high-interest astrobiology targets. In this work, we discuss the feasibility and advantages of using each of the aforementioned instrument techniques for the in situ search for biosignatures and present results on the autonomous characterization of biosignatures using multivariate statistical analysis techniques.

  14. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  15. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  16. A Report on The Data Acquisition and On-line Instrument Technique Development for FTL

    International Nuclear Information System (INIS)

    Sim, B. S.; Chi, D. Y.; Lee, C. Y.; Park, S. K.; Lee, J. M.; Ahn, S. H.; Kim, Y. K.

    2009-01-01

    Documents produced during the design, procurement manufacturing, and commissioning stage for the instruments such as SPND, Thermocouple, and LVDT which are installed on the In-pile section(IPS) of the fuel test loop(FTL) are gathered together. The values measured by the instruments are stored on the database of the data acquisition system(DAS) and displayed through both DAS and remote monitoring system installed on the users office. The commissioning status and the problems and items to be improved which are revealed during the commissioning stage are described. The report will be used for the development and operation of the instruments in the near future

  17. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  18. Agri-Environmental Policy Measures in Israel: The Potential of Using Market-Oriented Instruments

    Science.gov (United States)

    Amdur, Liron; Bertke, Elke; Freese, Jan; Marggraf, Rainer

    2011-05-01

    This paper examines the possibilities of developing agri-environmental policy measures in Israel, focusing on market-oriented instruments. A conceptual framework for developing agri-environmental policy measures is presented, first in very broad lines (mandatory regulations, economic instruments and advisory measures) and subsequently focusing on economic instruments, and specifically, on market-oriented ones. Two criteria of choice between the measures are suggested: their contribution to improving the effectiveness of the policy; and the feasibility of their implementation. This is the framework used for analyzing agri-environmental measures in Israel. Israel currently implements a mix of mandatory regulations, economic instruments and advisory measures to promote the agri-environment. The use of additional economic instruments may improve the effectiveness of the policy. When comparing the effectiveness of various economic measures, we found that the feasibility of implementation of market-oriented instruments is greater, due to the Israeli public's preference for strengthening market orientation in the agricultural sector. Four market-oriented instruments were practiced in a pilot project conducted in an Israeli rural area. We found that in this case study, the institutional feasibility and acceptance by stakeholders were the major parameters influencing the implementation of the market-oriented instruments, whereas the instruments' contribution to enhancing the ecological or economic effectiveness were hardly considered by the stakeholders as arguments in favor of their use.

  19. Exploring the Cosmic Frontier Astrophysical Instruments for the 21st Century

    CERN Document Server

    Lobanov, Andrei P; Cesarsky, Catherine; Diamond, Phillip J

    2007-01-01

    In the coming decades, astrophysical science will benefit enormously from the construction and operation of several major international ground- and space based facilities, such as ALMA, Herschel/Planck, and SKA in the far infrared to radio band, Extremely Large Telescopes, JWST and GAIA in the optical to near infrared regime, XEUS and Constellation-X in the X-ray, and GLAST in the Gamma-ray regime. These and other new instruments will have a major impact in a wide range of scientific topics including the cosmological epoch of reionization, galactic dynamics and nuclear activity, stellar astronomy, extra-solar planets, gamma-ray bursts, X-ray binaries, and many others. On May 18-21, 2004, the Max-Planck-Society’s Harnack-Haus in Dahlem, Berlin hosted the international symposium "Exploring the Cosmic Frontier: Astrophysical Instruments for the 21st Century". The symposium in Berlin was dedicated to exploring the complementarity and synergies between different branches of astrophysical research, by presenting ...

  20. 15 CFR 301.3 - Application for duty-free entry of scientific instruments.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Application for duty-free entry of scientific instruments. 301.3 Section 301.3 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE MISCELLANEOUS...

  1. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  2. Optimization of an analytical electron microscope for x-ray microanalysis: instrumental problems

    International Nuclear Information System (INIS)

    Bentley, J.; Zaluzec, N.J.; Kenik, E.A.; Carpenter, R.W.

    1979-01-01

    The addition of an energy dispersive x-ray spectrometer to a modern transmission or scanning transmission electron microscope can provide a powerful tool in the characterization of the materials. Unfortunately this seemingly simple modification can lead to a host of instrumental problems with respect to the accuracy, validity, and quality of the recorded information. This tutorial reviews the complications which can arise in performing x-ray microanalysis in current analytical electron microscopes. The first topic treated in depth is fluorescence by uncollimated radiation. The source, distinguishing characteristics, effects on quantitative analysis and schemes for elimination or minimization as applicable to TEM/STEMs, D-STEMs and HVEMs are discussed. The local specimen environment is considered in the second major section where again detrimental effects on quantitative analysis and remedial procedures, particularly the use of low-background specimen holers, are highlighted. Finally, the detrimental aspects of specimen contamination, insofar as they affect x-ray microanalysis, are discussed. It is concluded that if the described preventive measures are implemented, reliable quantitative analysis is possible

  3. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  4. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  5. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    Science.gov (United States)

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  6. Identifying instruments to quantify financial management skills in adults with acquired cognitive impairments.

    Science.gov (United States)

    Engel, Lisa; Bar, Yael; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2016-01-01

    Financial management skills-that is, the skills needed to handle personal finances such as banking and paying bills-are essential to a person's autonomy, independence, and community living. To date, no comprehensive review of financial management skills instruments exists, making it difficult for clinicians and researchers to choose relevant instruments. The objectives of this review are to: (a) identify all available instruments containing financial management skill items that have been used with adults with acquired cognitive impairments; (b) categorize the instruments by source (i.e., observation based, self-report, proxy report); and (c) describe observation-based performance instruments by populations, overarching concepts measured, and comprehensiveness of financial management items. Objective (c) focuses on observation-based performance instruments as these measures can aid in situations where the person with cognitive impairment has poor self-awareness or where the proxy has poor knowledge of the person's current abilities. Two reviewers completed two systematic searches of five databases. Instruments were categorized by reviewing published literature, copies of the instruments, and/or communication with instrument authors. Comprehensiveness of items was based on nine key domains of financial management skills developed by the authors. A total of 88 discrete instruments were identified. Of these, 44 were categorized as observation-based performance and 44 as self- and/or proxy-reports. Of the 44 observation-based performance instruments, 8 had been developed for acquired brain injury populations and 24 for aging and dementia populations. Only 7 of the observation-based performance instruments had items spanning 6 or more of the 9 financial management skills domains. The majority of instruments were developed for aging and dementia populations, and few were comprehensive. This review provides foundation for future instrument psychometric and clinimetric

  7. Reactor safety instrumentation of Paks NPP (experience and perspective)

    International Nuclear Information System (INIS)

    Elo, S.; Hamar, K.

    1993-01-01

    The majority of the existing control and protection systems in nuclear power plants use old analog technology and design philosophy. Maintenance and the procurement of spare parts is becoming increasingly difficult. In general there is an age degradation concern. Aging degradation in nuclear power plants must be effectively managed to avoid a loss of vital safety function, shutdown of the station, a reduced power generation, or any failure leading to expensive repair. Even with the best efforts in developing reliable and long life instrumentation and control systems for nuclear power plants it is expected that these systems for most plants will require replacements during the life of the plants. The instrumentation and control system of the nuclear power plants designed during the 70's and constructed in the 80's went out-of-date since nuclear safety is not a static concept and the digital computer technology has undergone rapid improvements during the 70's and 80's. Simultaneously the operation and the maintenance of the I ampersand C system of those plants described above becomes more and more difficult and expensive. In this context the pure quality of the former Soviet designed process instrumentation system increases the needs of upgrading this system. The author reviews the main design characteristics of the reactor safety instrumentation of the Paks NPP. Further he attempts to convey the perspective on upgrading the reactor safety instrumentation as seen by the HAEC and its Nuclear Safety Inspectorate

  8. Review of the Tandem Mirror Experiment-Upgrade (TMX-U) machine-parameter-instrumentation system

    International Nuclear Information System (INIS)

    Kane, R.J.; Coffield, F.E.; Coutts, G.W.; Hornady, R.S.

    1983-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) machine consists of seven major machine subsystems: magnet system, neutral beam system, microwave heating (ECRH), ion heating (ICRH), gas fueling, stream guns, and vacuum system. Satisfactory performance of these subsystems is necessary to achieve the experimental objectives planned for TMX-U operations. Since the performance quality of the subsystem is important and can greatly affect plasma parameters, a 233-channel instrumentation system has been installed. Data from the instrumentation system are acquired and stored with the plasma diagnostic information. Thus, the details of the machine performance are available during post-shot analysis. This paper describes all the machine-parameter-instrumentation hardware, presents some typical data, and outlines how the data are used

  9. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  10. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  11. Lessons Learned From the Analysis of the SAFOD Downhole Instrument Package.

    Science.gov (United States)

    Johnson, Wade; Mencin, David; Mattioli, Glen

    2013-04-01

    In September of 2008 a downhole instrument package (DIP) consisting of a string of seismometers and tilt meters in isolated pressure vessels (PODs) was installed in the SAFOD main borehole. This package was designed to protect the sensors from the corrosive borehole environment and to operate for two years. The SAFOD borehole is not sealed at the bottom allowing borehole gasses and fluids infiltratration. Previous short-term installations of instruments in the SAFOD main borehole had also failed as a result of corrosion of the wireline cable head. The average failure time for these installations was two weeks. The use of stainless steel tubing connected to the pressure vessels through gas tight fittings was designed to block borehole fluid and gas infiltration of the individual instruments within the PODs. Unfortunately, the DIP completely failed within a month of its installation. In October of 2010, the DIP was removed from the borehole and a failure analysis was performed. This analysis involved to following steps: 1. Analysis of data to understand timeline of failure 2. Remove instrument safely, maintaining integrity of spliced section and documenting any external clues. Test instrument at surface 3. Open PODs in a way that allows for sampling and avoids damaging instruments. 4. Chemical analysis of fluids recovered from splices and PODs. 5. Instrument failure analysis by the instrument manufacturers. The analysis found that there were several design flaws in the DIP. This included the use of motor oil to take up air space in the individual PODs, use of a large number of gas tight seals, lack of internal seals, poorly done solder joints, use of non-temperature rated sensors, and lack of management oversight. The lessons learned from the attempts to instrument the SAFOD borehole are critical to the success of future deep borehole projects.

  12. The Atacama Cosmology Telescope: The Receiver and Instrumentation

    Science.gov (United States)

    Swetz, D. S.; Ade, P. A. R.; Amiri, M.; Appel, J. W.; Burger, B.; Devlin, M. J.; Dicker, S. R.; Doriese, W. B.; Essinger-Hileman, T.; Fisher, R. P.; hide

    2010-01-01

    The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the Cosmic Microwave Background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Taco in the Atacama Desert, at an altitude of 5190 meters. A six-met.er off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The receiver features three WOO-element arrays of transition-edge sensor bolometers for observations at 148 GHz, 218 GHz, and 277 GHz. Each detector array is fed by free space mm-wave optics. Each frequency band has a field of view of approximately 22' x 26'. The telescope was commissioned in 2007 and has completed its third year of operations. We discuss the major components of the telescope, camera, and related systems, and summarize the instrument performance.

  13. Profiles of Motivated Self-Regulation in College Computer Science Courses: Differences in Major versus Required Non-Major Courses

    Science.gov (United States)

    Shell, Duane F.; Soh, Leen-Kiat

    2013-12-01

    The goal of the present study was to utilize a profiling approach to understand differences in motivation and strategic self-regulation among post-secondary STEM students in major versus required non-major computer science courses. Participants were 233 students from required introductory computer science courses (194 men; 35 women; 4 unknown) at a large Midwestern state university. Cluster analysis identified five profiles: (1) a strategic profile of a highly motivated by-any-means good strategy user; (2) a knowledge-building profile of an intrinsically motivated autonomous, mastery-oriented student; (3) a surface learning profile of a utility motivated minimally engaged student; (4) an apathetic profile of an amotivational disengaged student; and (5) a learned helpless profile of a motivated but unable to effectively self-regulate student. Among CS majors and students in courses in their major field, the strategic and knowledge-building profiles were the most prevalent. Among non-CS majors and students in required non-major courses, the learned helpless, surface learning, and apathetic profiles were the most prevalent. Students in the strategic and knowledge-building profiles had significantly higher retention of computational thinking knowledge than students in other profiles. Students in the apathetic and surface learning profiles saw little instrumentality of the course for their future academic and career objectives. Findings show that students in STEM fields taking required computer science courses exhibit the same constellation of motivated strategic self-regulation profiles found in other post-secondary and K-12 settings.

  14. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

    Science.gov (United States)

    Haïkel, Y; Serfaty, R; Bateman, G; Senger, B; Allemann, C

    1999-06-01

    The absence of adequate testing standards for engine-driven nickel-titanium (NiTi) instruments necessitates further study of these instruments in all areas. This study examined three groups of engine-driven rotary NiTi endodontic instruments (Profile, Hero, and Quantec) and assessed the times for dynamic fracture in relation to the radius of curvature to which the instruments were subjected during preparation, with the instrument diameter determined by size and taper and the mode by which the fracture occurred. Ten instruments were randomly selected representing each size and taper for each group and for each radius of curvature: 600 in total. The instruments were rotated at 350 rpm and introduced into a tempered steel curve that simulated a canal. Two radii of curvature of canals were used: 5 and 10 mm. Time at fracture was noted for all files, and the fracture faces of each file were analyzed with scanning electron microscopy. Radius of curvature was found to be the most significant factor in determining the fatigue resistance of the files. As radius of curvature decreased, fracture time decreased. Taper of files was found to be significant in determining fracture time. As diameter increased, fracture time decreased. In all cases, fracture was found to be of a ductile nature, thus implicating cyclic fatigue as a major cause of failure and necessitating further analyses and setting of standards in this area.

  15. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders

    NARCIS (Netherlands)

    Abma, F.I.; van der Klink, J.J.L.; Terwee, C.B.; Amick, B.C.; Bultmann, U.

    2012-01-01

    Objectives During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in

  16. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  17. Evaluation of a screening instrument for essential tremor

    DEFF Research Database (Denmark)

    Lorenz, Delia; Papengut, Frank; Frederiksen, Henrik

    2008-01-01

    To evaluate a screening instrument for essential tremor (ET) consisting of a seven-item questionnaire and a spiral drawing. A total of 2,448 Danish twins aged 70 years or more and a second sample aged 60 years or more (n = 1,684) from a population-based northern German cross-sectional study (Pop....... Definite or probable ET was diagnosed in 104 patients, possible in 86 and other tremors in 98 patients. The sensitivity of the screening instrument was 70.5%, the positive predictive value was 64.9%, the specificity was 68.2%, and the negative predictive value was 73.5%. Tremor severity correlated...... significantly with higher spiral scores and more positive items. More patients were identified by spiral drawing in all tremor groups. The interrater and intrarater reliability for spirals ranged from 0.7 to 0.8 using intraclass coefficient. A cluster analysis revealed that the questionnaire can be reduced...

  18. Nuclear medicine and imaging research (instrumentation and quantitative methods of evaluation)

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.; Chen, C.T.

    1992-07-01

    This document is the annual progress report for project entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Progress is reported in separate sections individually abstracted and indexed for the database. Subject areas reported include theoretical studies of imaging systems and methods, hardware developments, quantitative methods of evaluation, and knowledge transfer: education in quantitative nuclear medicine imaging

  19. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  20. The Impact of Instrument-Specific Musical Training on Rhythm Perception and Production.

    Science.gov (United States)

    Matthews, Tomas E; Thibodeau, Joseph N L; Gunther, Brian P; Penhune, Virginia B

    2016-01-01

    Studies comparing musicians and non-musicians have shown that musical training can improve rhythmic perception and production. These findings tell us that training can result in rhythm processing advantages, but they do not tell us whether practicing a particular instrument could lead to specific effects on rhythm perception or production. The current study used a battery of four rhythm perception and production tasks that were designed to test both higher- and lower-level aspects of rhythm processing. Four groups of musicians (drummers, singers, pianists, string players) and a control group of non-musicians were tested. Within-task differences in performance showed that factors such as meter, metrical complexity, tempo, and beat phase significantly affected the ability to perceive and synchronize taps to a rhythm or beat. Musicians showed better performance on all rhythm tasks compared to non-musicians. Interestingly, our results revealed no significant differences between musician groups for the vast majority of task measures. This was despite the fact that all musicians were selected to have the majority of their training on the target instrument, had on average more than 10 years of experience on their instrument, and were currently practicing. These results suggest that general musical experience is more important than specialized musical experience with regards to perception and production of rhythms.

  1. The impact of instrument-specific musical training on rhythm perception and production

    Directory of Open Access Journals (Sweden)

    Tomas Edward Matthews

    2016-02-01

    Full Text Available Various studies have shown that musical training can improve rhythmic perception and production. These findings tell us that music training can result in rhythm processing advantages but they do not tell us whether practicing a particular instrument could lead to specific effects on rhythm perception or production. The current study used a battery of four rhythm perception and production tasks that were designed to test both higher- and lower-level aspects of rhythm processing. Four groups of musicians (drummers, singers, pianists, string players and a control group of non-musicians were tested. Within-task differences in performance showed that factors such as meter, metrical complexity, tempo and beat phase significantly affected the ability to perceive and synchronize taps to a rhythm or beat. Musicians showed better performance on all rhythm tasks compared to non-musicians. Interestingly, our results revealed no significant differences between musician groups for the vast majority of task measures. This is despite the fact that all musicians were selected to have the majority of their training on the target instrument, had on average more than ten years of experience on their instrument, and were currently practicing. These results suggest that general musical experience is more important than specialized musical experience with regards to perception and production of rhythms.

  2. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    Science.gov (United States)

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  3. FMIT diagnostic instrumentation

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Chamberlin, D.D.

    1985-01-01

    The Fusion Materials Irradiation Test facility (FMIT) cw prototype accelerator has noninterceptive beamline instrumentation to measure beam parameters. The transverse emittances and beam profiles are measured with an array of photodiode sensors viewing light emitted from the beam region. Tomographic reconstructions of both spatial-density distributions and of transverse-emittance distributions are performed throughout a quadrupole focusing section. Beam bunches passing through capacitive probes produce bipolar waveforms whose zero crossing corresponds to the bunch's longitudinal centroid. By measuring the time required for a bunch to travel the known distance between two probes, velocity and energy are determined. A toroidal transformer measures the average ac beam current. Beam spill is measured by a set of movable jaws that intercept the beam edges. Each jaw contains a water flow channel whose flow rate and differential temperature are measured to derive a transverse power distribution. Beam centroid position is measured by a four-lobe, magnetic-loop pickup. 5 refs., 6 figs

  4. Sociodemographic Correlates of Unipolar Major Depression among the Chinese Elderly in Klang Valley, Malaysia: An Epidemiological Study

    Science.gov (United States)

    Verma, Rohit Kumar; Chakravarthy, Srikumar; Barua, Ankur

    2014-01-01

    Background. Depression, as one of the most disabling diseases around the world, had caught the global concern with its rising prevalence rate. There is a growing need of detecting depression, particularly in the old age population which is often left being overlooked. Methods. We conducted a cross-sectional community-based study which included 150 Chinese elderly aged 60 and above within Klang Valley area. We obtained the sociodemographic profiles and assessed the status of well-being, depression, and cognitive function of the participants with the help of instruments: WHO Five-Item Well-Being Index, Major (ICD-10) Depression Inventory, and 6-Item Cognitive Impairment Test. Results. We found that the prevalence of depression among the Chinese elderly within Klang Valley region was 10.7%. With multiple logistic regression, decision to consult doctor on depressed mood or memory problem and presence of cognitive impairment were shown to be significantly associated with unipolar major depression, whereas wellbeing status was also found to be statistically correlated with depression in univariate analysis. Conclusion. The prevalence of unipolar depression among Chinese elderly within Klang Valley, Malaysia presented that there was an increased trend compared to the previous studies. PMID:25544962

  5. Sociodemographic correlates of unipolar major depression among the Chinese elderly in Klang Valley, Malaysia: an epidemiological study.

    Science.gov (United States)

    Verma, Rohit Kumar; Min, Tan Hui; Chakravarthy, Srikumar; Barua, Ankur; Kar, Nilamadhab

    2014-01-01

    Depression, as one of the most disabling diseases around the world, had caught the global concern with its rising prevalence rate. There is a growing need of detecting depression, particularly in the old age population which is often left being overlooked. We conducted a cross-sectional community-based study which included 150 Chinese elderly aged 60 and above within Klang Valley area. We obtained the sociodemographic profiles and assessed the status of well-being, depression, and cognitive function of the participants with the help of instruments: WHO Five-Item Well-Being Index, Major (ICD-10) Depression Inventory, and 6-Item Cognitive Impairment Test. We found that the prevalence of depression among the Chinese elderly within Klang Valley region was 10.7%. With multiple logistic regression, decision to consult doctor on depressed mood or memory problem and presence of cognitive impairment were shown to be significantly associated with unipolar major depression, whereas wellbeing status was also found to be statistically correlated with depression in univariate analysis. The prevalence of unipolar depression among Chinese elderly within Klang Valley, Malaysia presented that there was an increased trend compared to the previous studies.

  6. Sociodemographic Correlates of Unipolar Major Depression among the Chinese Elderly in Klang Valley, Malaysia: An Epidemiological Study

    Directory of Open Access Journals (Sweden)

    Rohit Kumar Verma

    2014-01-01

    Full Text Available Background. Depression, as one of the most disabling diseases around the world, had caught the global concern with its rising prevalence rate. There is a growing need of detecting depression, particularly in the old age population which is often left being overlooked. Methods. We conducted a cross-sectional community-based study which included 150 Chinese elderly aged 60 and above within Klang Valley area. We obtained the sociodemographic profiles and assessed the status of well-being, depression, and cognitive function of the participants with the help of instruments: WHO Five-Item Well-Being Index, Major (ICD-10 Depression Inventory, and 6-Item Cognitive Impairment Test. Results. We found that the prevalence of depression among the Chinese elderly within Klang Valley region was 10.7%. With multiple logistic regression, decision to consult doctor on depressed mood or memory problem and presence of cognitive impairment were shown to be significantly associated with unipolar major depression, whereas wellbeing status was also found to be statistically correlated with depression in univariate analysis. Conclusion. The prevalence of unipolar depression among Chinese elderly within Klang Valley, Malaysia presented that there was an increased trend compared to the previous studies.

  7. Instrument design and automation

    International Nuclear Information System (INIS)

    Wernlund, R.F.

    1984-01-01

    The ion mobility spectrometer-mass spectrometer (IMS-MS) is described and consists of two separate instruments coupled in tandem: an ion mobility spectrometer coupled to a quadrupole mass spectrometer. The two insturments operate at different pressures in a synergistic manner, supplying both drift time and mass information about ions which are formed at atmospheric pressure in the ion mobility spectrometer tube. Two types of ion intensity signals are presented to the data processor. The IMS produces an analog voltage with major components from dc to 5 KHz. The mass spectrometer signal output resides in the pulse count rate derived from a series of TTL level pulses where each pulse represents the arrival of a single ion. The hardware, software, interfacing capabilities and basic data acquisition program are described in detail

  8. Exploring the cosmic frontier. Astrophysical instruments for the 21st century

    International Nuclear Information System (INIS)

    Lobanov, A.P.; Zensus, J.A.; Cesarsky, C.; Diamond, P.

    2007-01-01

    In the coming decades, astrophysical science will benefit enormously from the construction and operation of several major international ground- and space based facilities, such as ALMA, Herschel/Planck, and SKA in the far infrared to radio band, Extremely Large Telescopes, JWST and GAIA in the optical to near infrared regime, XEUS and Constellation-X in the X-ray, and GLAST in the Gamma-ray regime. These and other new instruments will have a major impact in a wide range of scientific topics including the cosmological epoch of reionization, galactic dynamics and nuclear activity, stellar astronomy, extra-solar planets, gamma-ray bursts, X-ray binaries, and many others. On May 18-21, 2004, the Max-Planck-Society's Harnack-Haus in Dahlem, Berlin hosted the international symposium ''Exploring the Cosmic Frontier: Astrophysical Instruments for the 21st Century''. The symposium in Berlin was dedicated to exploring the complementarity and synergies between different branches of astrophysical research, by presenting and discussing the fundamental scientific problems that will be addressed by major future astrophysical facilities in the next few decades. This book contains 70 papers from the meeting and is intended to give a lasting account of a snapshot of an evolving scientific discourse and interaction throughout our field of research. (orig.)

  9. A cross-sectional pilot study of the Scottish early development instrument: a tool for addressing inequality

    Science.gov (United States)

    2013-01-01

    Background Early childhood is recognised as a key developmental phase with implications for social, academic, health and wellbeing outcomes in later childhood and indeed throughout the adult lifespan. Community level data on inequalities in early child development are therefore required to establish the impact of government early years’ policies and programmes on children’s strengths and vulnerabilities at local and national level. This would allow local leaders to target tailored interventions according to community needs to improve children’s readiness for the transition to school. The challenge is collecting valid data on sufficient samples of children entering school to derive robust inferences about each local birth cohort’s developmental status. This information needs to be presented in a way that allows community stakeholders to understand the results, expediting the improvement of preschool programming to improve future cohorts’ development in the early years. The aim of the study was to carry out a pilot to test the feasibility and ease of use in Scotland of the 104-item teacher-administered Early Development Instrument, an internationally validated measure of children’s global development at school entry developed in Canada. Methods Phase 1 was piloted in an education district with 14 Primary 1 teachers assessing a cohort of 154 children, following which the instrument was adapted for the Scottish context (Scottish Early Development Instrument: SEDI). Phase 2 was then carried out using the SEDI. Data were analysed from a larger sample of 1090 participants, comprising all Primary 1 children within this school district, evaluated by 68 teachers. Results The SEDI displayed adequate psychometric and discriminatory properties and is appropriate for use across Scotland without any further modifications. Children in the lowest socioeconomic status quintiles were 2–3 times more likely than children in the most affluent quintile to score low in at

  10. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping and Instrumentation Control (PIC) skid ''M''. The Scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Service's (SFS) shop upon completion of construction of the PIC skid

  11. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping Instrumentation and Control (PIC) skid ''V''. The scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Services (SFS) shop upon completion of the construction of the PIC skid

  12. Deformation and fracture of K3 rotary nickel-titanium endodontic instruments after clinical use.

    Science.gov (United States)

    Shen, S M; Deng, M; Wang, P P; Chen, X M; Zheng, L W; Li, H L

    2016-11-01

    The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P  0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  14. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

    Science.gov (United States)

    Scelza, Pantaleo; Harry, Davidowicz; Silva, Licinio Esmeraldo da; Barbosa, Igor Bastos; Scelza, Miriam Zaccaro

    2015-01-01

    The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p fatigue tests (p ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  15. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  16. The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

    Science.gov (United States)

    Ustun, Yakup; Aslan, Tugrul; Sagsen, Burak; Kesim, Bertan

    2015-01-01

    The aim of the present study was to investigate the incidence of dentinal microcracks caused by different preparation techniques. 120 extracted human mandibular incisor teeth were divided into five experimental groups and one control group (n = 20): Group 1: Hand preparation with balanced force technique up to #25 K-file. Group 2: Preparation with only ProTaper F2 instrument in a reciprocating movement. Group 3: Preparation with Reciproc R25 instrument in a reciprocating movement. Group 4: Preparation with ProTaper instruments up to F2 instrument. Group 5: Preparation with ProTaper Next instruments up to X2 instrument. No procedure was applied to control group. The roots were sectioned horizontally at 3, 6 and 9 mm from the apex and examined. Absence or presence of dentinal microcracks was noted. The Chi-square test was performed to compare the appearance of cracked roots between all groups. There were no significant differences among the groups (P > 0.05). In conclusion, except the hand file and control group, all experimental groups showed microcrack formations.

  17. Wound Infection following Caesarean Section in a University ...

    African Journals Online (AJOL)

    Background: Caesarean section is a common operation in obstetric practice, but there is a general aversion to caesarean section amongst Nigerian women due to a myriad of reasons amongst which are its associated morbidity and mortality. Surgical site infection following caesarean section is both a major cause of ...

  18. Group fellowship training in nuclear spectroscopy instrumentation maintenance at the Seibersdorf Laboratories

    International Nuclear Information System (INIS)

    Xie, Y.; Abdel-Rassoul, A.A.

    1989-01-01

    Nuclear spectroscopy instruments are important tools for nuclear research and applications. Several types of nuclear spectrometers are being sent to numerous laboratories in developing countries through technical co-operation projects. These are mostly sophisticated systems based on different radiation detectors, analogue and digital circuitry. In most cases, they use microprocessor or computer techniques involving software and hardware. Maintenance service and repair of these systems is a major problem in many developing countries because suppliers do not set up service stations. The Agency's Laboratories at Seibersdorf started conducting group fellowship training on nuclear spectroscopy instrumentation maintenance in 1987. This article describes the training programme

  19. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  20. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  1. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery

    Directory of Open Access Journals (Sweden)

    Sepucha Karen R

    2012-06-01

    Full Text Available Abstract Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70 and discriminated between providers and patients (mean difference 35%, p  Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed.

  2. Translation, cross-cultural adaptation and validation of an HIV/AIDS knowledge and attitudinal instrument.

    Science.gov (United States)

    Zometa, Carlos S; Dedrick, Robert; Knox, Michael D; Westhoff, Wayne; Siri, Rodrigo Simán; Debaldo, Ann

    2007-06-01

    An instrument developed in the United States by the Centers for Disease Control and Prevention to assess HIV/AIDS knowledge and four attitudinal dimensions (Peer Pressure, Abstinence, Drug Use, and Threat of HIV Infection) and an instrument developed by Basen-Engquist et al. (1999) to measure abstinence and condom use were translated, cross-culturally adapted, and validated for use with Spanish-speaking high school students in El Salvador. A back-translation of the English version was cross-culturally adapted using two different review panels and pilot-tested with Salvadorian students. An expert panel established content validity, and confirmatory factor analysis provided support for construct validity. Results indicated that the methodology was successful in cross-culturally adapting the instrument developed by the Centers for Disease Control and Prevention and the instrument developed by Basen-Engquist et al. The psychometric properties of the knowledge section were acceptable and there was partial support for the four-factor attitudinal model underlying the CDC instrument and the two-factor model underlying the Basen-Engquist et al. instrument. Additional studies with Spanish-speaking populations (either in the United States or Latin America) are needed to evaluate the generalizability of the present results.

  3. Health Status Measurement Instruments in Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Yves Lacasse

    1997-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is associated with primary respiratory impairment, disability and handicap, as well as with secondary impairments not necessarily confined to the respiratory system. Because the primary goals of managing patients with COPD include relief of dyspnea and the improvement of health-related quality of life (HRQL, a direct measurement of HRQL is important. Fourteen disease-specific and nine generic questionnaires (four health profiles and five utility measures most commonly used to measure health status in patients with COPD were reviewed. The measures were classified according to their domain of interest, and their measurement properties - specifications, validity, reliability, responsiveness and interpretability - were described. This review suggests several findings. Currently used health status instruments usually refer to the patients’ perception of performance in three major domains of HRQL - somatic sensation, physical and occupational function, and psychological state. The choice of a questionnaire must be related to its purpose, with a clear distinction being made between its evaluative and discriminative function. In their evaluative function, only a few instruments fulfilled the criteria of responsiveness, and the interpretability of most questionnaires is limited. Generic questionnaires should not be used alone in clinical trials as evaluative instruments because of their inability to detect change over time. Further validation and improved interpretability of existing instruments would be of greater benefit to clinicians and scientists than the development of new questionnaires.

  4. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study.

    Science.gov (United States)

    Yilmaz, Ayca; Helvacioglu-Yigit, Dilek; Gur, Cansu; Ersev, Handan; Kiziltas Sendur, Gullu; Avcu, Egemen; Baydemir, Canan; Abbott, Paul Vincent

    2017-01-01

    The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9  μ m resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR) or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  5. Regulatory instrument review: Aging management of LWR cables, containment and basemat, reactor coolant pumps, and motor-operated valves

    International Nuclear Information System (INIS)

    Werry, E.V.; Somasundaram, S.

    1995-09-01

    The results of Stage 2 of the Regulatory Instrument Review are presented in this volume. Selected regulatory instruments, such as the Code of Federal Regulations (CFR), US Nuclear Regulatory Commission (NRC), Regulatory Guides, and ASME Codes, were investigated to determine the extent to which these regulations apply aging management to selected safety-related components in nuclear power plants. The Regulatory Instrument Review was funded by the NRC under the Nuclear Plant Aging Research (NPAR) program. Stage 2 of the review focused on four safety-related structures and components; namely, cables, containment and basemat, reactor coolant pumps, and motor-operated valves. The review suggests that the primary-emphasis of the regulatory instruments was on the design, construction, start-up, and operation of a nuclear power plant, and that aging issues were primarily addressed after an aging-related problem was recognized. This Stage 2 review confirms the results of the prior review; (see Regulatory Instrument Review: Management of Aging of LWR Major Safety-Related Components NUREG/CR-5490. The observations indicate that the regulations generally address management of age-related degradation indirectly. Specific age-related degradation phenomena frequently are dealt with in bulletins and notices or through generic issues, letters, etc. The major recommendation of this report, therefore, is that the regulatory instruments should more directly and explicitly address the aging phenomenon and the management of the age-related degradation process

  6. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

    Science.gov (United States)

    LaKind, Judy S.; Sobus, Jon R.; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J.; Arbuckle, Tye E.; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P.

    2015-01-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. PMID:25137624

  7. Quality assurance aspects of the major procurements for the Large Coil Test Facility

    International Nuclear Information System (INIS)

    Taylor, D.J.; Thompson, P.B.; Ryan, T.L.; Queen, C.C.; Halstead, E.L.; Murphy, J.L.; Wood, R.J.

    1983-01-01

    The Large Coil Test Facility (LCTF) project is comprised of the test stand, supporting cryogenic systems, instrumentation, data acquisition, and utilities necessary for testing the large superconducting coils of the Large Coil Program (LCP). A significant portion of the facility hardware has been obtained through procurement actions with industrial suppliers. This paper addresses the project's experience in formulation and execution of quality assurance (QA) actions relative to several of the major items procured. Project quality assurance planning and specific features related to procurement activities for several of the more specialized test facility components are described. These component procurements include: (1) the coil test stand's major structural item (the bucking post) purchased from foreign industry; (2) fabrication and testing of high-current power supplies; (3) industrial fabrication of specialized instrumentation (voltage-tap signal conditioning modules); and (4) fabrication, installation, and testing of the liquid helium piping system

  8. TH-A-17A-01: Innovation in PET Instrumentation and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Casey, M [Siemens Healthcare, Knoxville, Tennessee (United States); Miyaoka, R [University of Washington, Seattle, WA (United States); Shao, Y [University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality and quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications.

  9. TH-A-17A-01: Innovation in PET Instrumentation and Applications

    International Nuclear Information System (INIS)

    Casey, M; Miyaoka, R; Shao, Y

    2014-01-01

    Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality and quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications

  10. Cultivation mode research of practical application talents for optical engineering major

    Science.gov (United States)

    Liu, Zhiying

    2017-08-01

    The requirements on science and technology graduates are more and higher with modern science progress and society market economy development. Because optical engineering major is with very long practicality, practice should be paid more attention from analysis of optical engineering major and students' foundation. To play role of practice to a large amount, the practice need be systemic and correlation. It should be combination of foundation and profundity. Modern foundation professional knowledge is studied with traditional optical concept and technology at the same time. Systemic regularity and correlation should be embodied in the contents. Start from basic geometrical optics concept, the optical parameter of optical instrument is analyzed, the optical module is built and ray tracing is completed during geometrical optics practice. With foundation of primary aberration calculation, the optical system is further designed and evaluated during optical design practice course. With the optical model and given instrument functions and requirements, the optical-mechanism is matched. The accuracy is calculated, analyzed and distributed in every motion segment. And the mechanism should guarantee the alignment and adjustment. The optical mechanism is designed during the instrument and element design practice. When the optical and mechanism drawings are completed, the system is ready to be fabricated. Students can complete grinding, polishing and coating process by themselves through optical fabricating practice. With the optical and mechanical elements, the system can be assembled and aligned during the thesis practice. With a set of correlated and logical practices, the students can acquire the whole process knowledge about optical instrument. All details are contained in every practice process. These practical experiences provide students working ability. They do not need much adaption anymore when they go to work after graduation. It is favorable to both student

  11. Mechanical Description of the Mars Climate Sounder Instrument

    Science.gov (United States)

    Jau, Bruno M.

    2008-01-01

    This paper introduces the Mars Climate Sounder (MCS) Instrument of the Mars Reconnaissance Orbiter (MRO) spacecraft. The instrument scans the Martian atmosphere almost continuously to systematically acquire weather and climate observations over time. Its primary components are an optical bench that houses dual telescopes with a total of nine channels for visible and infrared sensing, and a two axis gimbal that provides pointing capabilities. Both rotating joints consist of an integrated actuator with a hybrid planetary/harmonic transmission and a twist cap section that enables the electrical wiring to pass through the rotating joint. Micro stepping is used to reduce spacecraft disturbance torques to acceptable levels while driving the stepper motors. To ensure survivability over its four year life span, suitable mechanical components, lubrication, and an active temperature control system were incorporated. Some life test results and lessons learned are provided to serve as design guidelines for actuator parts and flex cables.

  12. About the study of irradiation effects on in-core instrumentation

    International Nuclear Information System (INIS)

    Angelino, G.

    1972-01-01

    The knowledge of in-core instrumentation performances is a very important item when irradiations of technological interest are concerned. When measurement of small changes in mechanical or thermal properties is of major importance, the effect of neutron and gamma irradiation on various transducers must be thoroughly evaluated. A rig mock-up was irradiated in the Triga Mark II Reactor of the Pavia University to assess the possibility of carrying out a study on irradiation effects on in-core instrumentation. Data on neutron flux distribution and γ-heating effect were collected from this preliminary experiment; at the same time a complete check was performed on rig assembling procedure, on the behaviour under operating conditions, and on the reactor loading and unloading operations. (author)

  13. Organic research section. 1984 review and 1985 programs

    International Nuclear Information System (INIS)

    Glass, R.W.

    1985-02-01

    This report reviews the major activities and accomplishments of the Organic Research Section in 1984 and presents the 1985 work program. The three major areas of the Section's research work are non-metallic materials which includes applications and uses of plastics, petroleum products, coatings and elastomers; reactor waste management; and activity transport/decontamination of nuclear systems. In 1984, 50% of the Section's resources were used on studies in support of nuclear generation, 13% on reactor waste, and 37% on general activities and work in support of utilization, transmission and distribution, and thermal and hydraulic programs. About 60% of the section's work was supported by transfer and revenue funds as a result of urgent short-term work requirements which resulted in 68% of the work falling into the technical investigation, consulting and testing categories

  14. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  15. 17 CFR 240.3b-13 - Definition of eligible OTC derivative instrument.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Definition of eligible OTC derivative instrument. 240.3b-13 Section 240.3b-13 Commodity and Securities Exchanges SECURITIES AND EXCHANGE... Under the Securities Exchange Act of 1934 Definitions § 240.3b-13 Definition of eligible OTC derivative...

  16. Falling caesarean section rate and improving intra-partum outcomes: a prospective cohort study.

    Science.gov (United States)

    Amin, Pina; Zaher, Summia; Penketh, Richard; Cherian, Sobha; Collis, Rachel E; Sanders, Julia; Bhal, Kiron

    2018-02-19

    To evaluate caesarean section (CS) rates and moderate to severe hypoxaemic ischaemic encephalopathy (HIE) rates with other core intra-partum outcomes following reconfiguration of maternity services in Cardiff, South Wales, UK. Cohort study of births from 2006 to 2015. A University tertiary referral centre for foetal and maternal medicine with 6000 births/year, University Hospital of Wales, United Kingdom. Data relating to births from 1 January 2006 to 31 December 2015 were extracted from the computerized maternity database on a yearly basis. Case notes of all mothers and babies for the same duration were hand searched for documentation of HIE. HIE data was also collected prospectively by neonatologist (SC) and obstetrician (PA). Incidence of caesarean section births, babies with moderate to severe HIE, instrumental vaginal births, obstetric anal sphincter injuries (OASIS) associated with instrumental delivery, and major post-partum haemorrhage (MPPH) of 2500 mL or more. During this 10-year period, a downward trend in emergency CS rate was seen from 15.6% in 2006 to 10.5% in 2015, reducing total CS rate from 25.5% in 2006 to 21.2% in 2015. A downward trend in the incidence of moderate and severe HIE was seen over the same period. There was an increase in operative vaginal births (OVB) from 12.8% to 15%. The rate of spontaneous vaginal births (SVB) remained stable. The incidence of OASIS remained constant and MPPH rate has fallen. Following amalgamation of two medium sized obstetric units and the opening of a Midwifery Led Unit (MLU), core intrapartum outcomes have improved. Contributing factors are the introduction of regular multidisciplinary training with enhanced team working, compulsory education for obstetricians and midwives on cardiotocograph (CTG) interpretation, increased consultant presence on delivery suite, robust risk management systems and broad multidisciplinary agreement on clinical guidelines promoting vaginal birth.

  17. A test section design to simulate horizontal two-phase air-water flow

    International Nuclear Information System (INIS)

    Faccini, Jose Luiz H.; Cesar, Silvia B.G.; Coutinho, Jorge A.; Freitas, Sergio Carlos; Addor, Pedro N.

    2002-01-01

    In this work an air-water two-phase flow horizontal test section assembling at Nuclear Engineering Institute (IEN) is presented. The test section was designed to allow four-phase flow patterns to be simulated: bubble flow, stratified flow, wave flow and slug flow. These flow patterns will be identified by non-conventional ultrasonic techniques which have been developed to meet this particular application. Based on the separated flow and drift-flux models the test section design steps are shown. A description of the test section and its instrumentation and data acquisition system is also provided. (author)

  18. Digital Processing for Modifying and Rearranging Rectilinear and Section Scan Data under Direct Observation

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D. E.; Edwards, R. Q. [University of Pennsylvania, Philadelphia, PA (United States)

    1969-01-15

    Our digital processor for scan data is an on-site instrument that is intermediate in complexity between conventional optical processing devices and large digital computers. It is designed to provide for a wide and flexible range of secondary data operations, direct picture display on a CRT screen, and full operator control of both processing and display operations at the time of viewing. The instrument does not require the user to learn complicated programing schemes. The operator is expected to be a physician who will control the parameters of interest by punching preset buttons on a keyboard while observing changes displayed on a CRT screen. The system functions primarily as an investigative tool for studying perception of scan information and ways of making this information more meaningful. Data operations include data bounding, spatial averaging, iso-count line generation, image addition and subtraction, and several forms of quantitative read-out for analysis of regional data. The instrument is intended to serve as a central processor and reader for data from several units. Investigations with this processor have served as a source of information leading to the design of more simple processing devices suitable for wider acceptance. For example, the Mark III rectilinear and transverse section brain scanner that has evolved from this project is expected to be a practical improvement of the brain study method. This instrument is designed especially for rapid brain scanning using {sup 99m}Tc pertechnetate. It has a self-contained computer, integrated digital circuits for compactness and economy, and provision for transverse section scanning. The advantages of this system are that it provides a more thorough study using both transverse section and rectilinear modes, rapid performance, precise orientation of section and rectilinear views to the patient position, efficient transfer of information between physician and machine during studies, and economy of design

  19. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  20. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  1. Novel mass spectrometric instrument for gaseous and particulate characterization and monitoring

    International Nuclear Information System (INIS)

    Coggiola, M.J.

    1993-04-01

    Under contract DE-AC21-92MC29116, SRI International will develop a unique new instrument that will be capable of providing real-time (< l minute), quantitative, chemical characterization of gaseous and particulate pollutants generated from DOE waste cleanup activities. The instrument will be capable of detecting and identifying volatile organic compounds, polynuclear aromatic hydrocarbons, heavy metals, and transuranic species released during waste cleanup activities. The instrument will be unique in its ability to detect and quantify in real-time these diverse pollutants in both vapor and particulate form. The instrument to be developed under this program will consist of several major components: (1) an isokinetic sampler capable of operating over a wide range of temperatures (up to 500 K) and flow rates; (2) a high pressure to low pressure transition and sampling region that efficiently separates particles from vapor-phase components for separate, parallel analyses; (3) two small mass spectrometers, one optimized for organic analysis using a unique field ionization source and one optimized for particulate characterization using thermal pyrolysis and electron-impact ionization (EI); and (4) a powerful personal computer for control and data acquisition

  2. Energy efficiency in existing detached housing. Danish experiences with different policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Gram-Hanssen, K.; Haunstrup Christensen, T. (Aalborg Univ., Danish Building Research Institute, Hoersholm (Denmark))

    2011-07-01

    This report contains a memo written as an input to the German project Enef-haus on energy-efficient restoration of single-family houses in Germany. The memo contains a summary of the Danish experiences divided into three main sections: first is a short historic overview of the Danish energy policy indicating when different relevant instruments have been introduced to increase the energy efficiency of privately owned single-family houses. Second is a short introduction to the Danish housing sector and its energy supplies. The third and main part of the report is an examination of the most recent and relevant instruments concluding both on the results concerning the impact of the instruments especially on owners of single-family houses and on more general experiences with their implementation. Finally the memo concludes on the general lessons that can be learned from the Danish experiences. (Author)

  3. Java Expert GUI framework for CERN beam instrumentation systems

    CERN Document Server

    Bart Pedersen, S; Jackson, S

    2011-01-01

    The CERN Beam Instrumentation Group’s software section has recently performed a study of the tools used to produce Java expert GUI applications. This paper will present the analysis that was made to understand the requirements for generic components and the resulting tools including a collection of Java components that have been made available for a wider audience. The paper will also discuss the prospect of using Maven as the deployment tool with its implications for developers and users.

  4. School Board Policy as an Instrument of Empowering Leadership in America.

    Science.gov (United States)

    Van Alfen, Curtis

    The role of school board policy as an instrument for empowering leadership is explored in this paper. Currently, the majority of policy handbooks are not designed to provide motivation or vision and are not part of an ongoing effort to create a congruence of district expectations. When policy becomes a statement of a school board's expectations…

  5. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users.

    Science.gov (United States)

    Prentiss, Sandra M; Friedland, David R; Fullmer, Tanner; Crane, Alison; Stoddard, Timothy; Runge, Christina L

    2016-09-01

    To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners. This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli. Normal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  6. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  8. Important variables for parents' postnatal sense of security: evaluating a new Swedish instrument (the PPSS instrument).

    Science.gov (United States)

    Persson, Eva K; Dykes, Anna-Karin

    2009-08-01

    to evaluate dimensions of both parents' postnatal sense of security the first week after childbirth, and to determine associations between the PPSS instrument and different sociodemographic and situational background variables. evaluative, cross-sectional design. 113 mothers and 99 fathers with children live born at term, from five hospitals in southern Sweden. mothers and fathers had similar feelings concerning postnatal sense of security. Of the dimensions in the PPSS instrument, a sense of midwives'/nurses' empowering behaviour, a sense of one's own general well-being and a sense of the mother's well-being as experienced by the father were the most important dimensions for parents' experienced security. A sense of affinity within the family (for both parents) and a sense of manageable breast feeding (for mothers) were not significantly associated with their experienced security. A sense of participation during pregnancy and general anxiety were significantly associated background variables for postnatal sense of security for both parents. For the mothers, parity and a sense that the father was participating during pregnancy were also significantly associated. more focus on parents' participation during pregnancy as well as midwives'/nurses' empowering behaviour during the postnatal period will be beneficial for both parents' postnatal sense of security.

  9. Novel mass spectrometric instrument for gaseous and particulate characterization and monitoring

    International Nuclear Information System (INIS)

    Coggiola, M.J.

    1994-02-01

    SRI International will develop a unique new instrument that will be capable of providing real-time (<1 minute), quantitative, chemical characterization of gaseous and particulate pollutants generated from DOE waste cleanup activities. The instrument will be capable of detecting and identifying volatile organic compounds, polynuclear aromatic hydrocarbons, heavy metals, and transuranic species released during waste cleanup activities. The instrument will be unique in its ability to detect and quantify in real-time these diverse pollutants in both vapor and particulate form. The instrument to be developed under this program will consist of several major components: (1) an isokinetic sampler capable of operating over a wide range of temperatures (up to 500 K) and flow rates; (2) a high pressure to low pressure transition and sampling region that efficiently separates particles from vapor-phase components for separate, parallel analyses; (3) two small mass spectrometers, one optimized for organic analysis using a unique field ionization source and one optimized for particulate characterization using thermal pyrolysis and electron-impact ionization (EI); and (4) a powerful personal computer for control and data acquisition. Initially, the instrument will be developed for targeted use in conjunction with the K-1435 Toxic Substances Control Act (TSCA) incinerator at the Oak Ridge National Laboratory K-25 site. Ultimately, the instrument will be designed to operate in the field at any cleanup site, located close to the stack or process vent, providing the plant operations personnel with real-time information and alarm capabilities. In addition, this instrument will be very broadly applicable for cleanup or sampling, for example, any time contaminated soil is moved or disturbed

  10. Operational Problems Associated with Head-Up Displays during Instrument Flight.

    Science.gov (United States)

    1980-10-01

    Force project engineers were Major Michael F. Rundle and Mr. William L. Welde . 41 4 TABLE OF CONTENTS Page ABBREVIATIONS...of Automotive Engineers SETP Society of Experimental Test Pilots SI Solid Instruments SNPL Syndicat National des Pilotes des Lignes (French ALPA) TACAN...Factors Relevent to Jet Upsets ," Lessons with Emphasis on Flight Mechanics from Operating Experience, Incidents, and Accidents, AGARD CP-76, 1971 153 J

  11. Fourth-generation spinal instrumentation: experience with adolescent idiopathic scoliosis at a tertiary care hospital in Pakistan

    Directory of Open Access Journals (Sweden)

    Fazal A

    2012-02-01

    Full Text Available Akil Fazal1, Riaz H Lakdawala21Hospital for Joint Disease, New York University, New York, USA; 2Section of Orthopaedics, Department of Surgery, The Aga Khan University Hospital, Karachi, PakistanObjective: To evaluate the radiological and functional outcome of surgical treatment of adolescent idiopathic scoliosis using fourth-generation posterior spinal instrumentation at The Aga Khan University, Karachi, Pakistan.Design: Case series.Place and duration of study: The Aga Khan University Hospital after a minimum of 2 years postoperatively.Patients and methods: A total of 20 patients with adolescent idiopathic scoliosis were recruited into the study and evaluated for radiological and functional outcome. The study period was from 2000 to 2005. Radiological outcome was assessed using Cobb angle measurement pre and postoperatively, hence assessing percentage correction. The lower instrumented vertebra was taken as the neutral vertebra and the level was recorded. Functional outcome was determined using the Scoliosis Research Society patient administered questionnaire. All patients were called to the clinic and asked to fill in the form. Those patients who were out of the city were mailed the forms and requested via telephone to complete and return.Results: Of the 20 patients operated on, twelve were female and eight were male. The average age at operation was 12.7 years. The mean Cobb angle was 69° preoperatively and 20° postoperatively, representing a percentage correction of 71%. The average duration of follow-up was 3.6 years. There was one major complication involving neurological injury post-op and two minor complications involving wound infection. The average Scoliosis Research Society score (on a scale of 1–5, with 5 being best for pain was 4.5, self-image was 4.2, functional status was 4.1, mental status was 3.8, and satisfaction was 4.4. There was no relationship between the percentage correction of scoliosis and the functional outcome

  12. Instrumentation and Controls evaluation for space nuclear power systems

    International Nuclear Information System (INIS)

    Anderson, J.L.; Oakes, L.C.

    1984-01-01

    Design of control and protection systems should be coordinated with the design of the neutronic, thermal-hydraulic, and mechanical aspects of the core and plant at the earliest possible stage of concept development. An integrated systematic design approach is necessary to prevent uncoordinated choices in one technology area from imposing impractical or impossible requirements in another. Significant development and qualification will be required for virtually every aspect of reactor control and instrumentation. In-core instrumentation widely used in commercial light water reactors will not likely be usable in the higher temperatures of a space power plant. Thermocouples for temperature measurement and gamma thermometers for flux measurement appear to be the only viable candidates. Recent developments in ex-core neutron detectors may provide achievable alternatives to in-core measurements. Reliable electronic equipment and high-temperature actuators will require major development efforts

  13. Landscape scale ecological monitoring as part of an EIA of major construction activities: experience at the Turkish section of the BTC crude oil pipeline project.

    Science.gov (United States)

    Sahin, Sükran; Kurum, Ekrem

    2009-09-01

    Ecological monitoring is a complementary component of the overall environmental management and monitoring program of any Environmental Impact Assessment (EIA) report. The monitoring method should be developed for each project phase and allow for periodic reporting and assessment of compliance with the environmental conditions and requirements of the EIA. Also, this method should incorporate a variance request program since site-specific conditions can affect construction on a daily basis and require time-critical application of alternative construction scenarios or environmental management methods integrated with alternative mitigation measures. Finally, taking full advantage of the latest information and communication technologies can enhance the quality of, and public involvement in, the environmental management program. In this paper, a landscape-scale ecological monitoring method for major construction projects is described using, as a basis, 20 months of experience on the Baku-Tbilisi-Ceyhan (BTC) Crude Oil Pipeline Project, covering Turkish Sections Lot B and Lot C. This analysis presents suggestions for improving ecological monitoring for major construction activities.

  14. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.

    Science.gov (United States)

    Inan, Ugur; Gonulol, Nihan

    2009-10-01

    In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis.

  15. Validation of the "SmoCess-GP" instrument - a short patient questionnaire for assessing the smoking cessation activities of general practitioners: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Wolf Jürgen

    2010-02-01

    Full Text Available Abstract Background We developed an instrument assessing the extent of smoking cessation activities by general practitioners (GPs within the Cologne Smoking Study (CoSmoS. The objective of the present study was to examine further psychometric quality of the "SmoCess-GP" instrument (Smoking Cessation by General Practitioners. Methods 127 current smokers who had participated in the Cologne Smoking Study (CoSmoS were included in our analyses. Confirmatory factor analysis (CFA was conducted to examine the model fit and to retest the single-factor structure of the instrument using the Mplus software. Further construct validity was tested with bivariate analysis using an instrument which measures patients' trust in physicians. Results CFA supported the unidimensional structure of the instrument. The factor loadings exceed the threshold of ≥ 0.50. All indicator reliabilities were higher than 0.30. The composite reliability was 0.86 and the average variance extracted (AVE resulted in a value of 0.50. The calculation of global fit indices identified a CFI value of 1.00 and for TLI a value of 1.02. The root mean square error of approximation (RMSEA indicates that 0% of the information is not accounted for by the model. The chi-square value was χ2df = 6 = 4.63 (p = 0.59. Analysis of discriminant validity resulted in a non-significiant correlation of r = 0.092 (p = 0.350. Conclusions Results indicate preliminary evidence for the construct validity of the "SmoCess-GP" instrument which therefore appears to be a promising tool for analyzing the extent of smoking cessation advice offered by GPs from the patients' perspective. Future research should examine the psychometric properties in a population based sample, further improvements of the instrument and should apply other methods of validation.

  16. Effects of instrumentation time on microleakage of resin-modified glass ionomer cements.

    Science.gov (United States)

    Yap, Adrian U J; Yeo, Egwin J C; Yap, W Y; Ong, Debbie S B; Tan, Jane W S

    2003-01-01

    This study investigated the effect of instrumentation time on the microleakage of resin-modified glass ionomer cements (RMGICs). Class V cavities were prepared on buccal and lingual/ palatal surfaces of 64 freshly extracted non-carious premolars. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]). The restored teeth were randomly divided into two groups of 32 teeth. Finishing/polishing was done immediately after light-polymerization in one group and was delayed for one week in the other group. The following finishing/polishing systems were evaluated: (a) Robot Carbides (RC); (b) SuperSnap (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each instrumentation time, material and finishing/polishing system combination was 8. Storage medium for both immediate and delayed instrumentation groups was distilled water at 37 degrees C during the hiatus period. The teeth were subsequently subjected to dye penetration testing (0.5% basic fushcin), sectioned and scored. Data were analyzed using Kruskal-Wallis and Mann-Whitney U tests at significance level 0.05. For PF, significant difference in enamel leakage was observed between immediate and delayed instrumentation with SS and CS. Significant differences in dentin leakage were also observed between the two instrumentation times for SS. For FT, significant differences in leakage between instrumentation times were observed only in dentin and with RC. Where significant differences in dye penetration scores existed, delayed finishing/polishing resulted in less microleakage.

  17. Neural mechanisms of reinforcement learning in unmedicated patients with major depressive disorder.

    Science.gov (United States)

    Rothkirch, Marcus; Tonn, Jonas; Köhler, Stephan; Sterzer, Philipp

    2017-04-01

    According to current concepts, major depressive disorder is strongly related to dysfunctional neural processing of motivational information, entailing impairments in reinforcement learning. While computational modelling can reveal the precise nature of neural learning signals, it has not been used to study learning-related neural dysfunctions in unmedicated patients with major depressive disorder so far. We thus aimed at comparing the neural coding of reward and punishment prediction errors, representing indicators of neural learning-related processes, between unmedicated patients with major depressive disorder and healthy participants. To this end, a group of unmedicated patients with major depressive disorder (n = 28) and a group of age- and sex-matched healthy control participants (n = 30) completed an instrumental learning task involving monetary gains and losses during functional magnetic resonance imaging. The two groups did not differ in their learning performance. Patients and control participants showed the same level of prediction error-related activity in the ventral striatum and the anterior insula. In contrast, neural coding of reward prediction errors in the medial orbitofrontal cortex was reduced in patients. Moreover, neural reward prediction error signals in the medial orbitofrontal cortex and ventral striatum showed negative correlations with anhedonia severity. Using a standard instrumental learning paradigm we found no evidence for an overall impairment of reinforcement learning in medication-free patients with major depressive disorder. Importantly, however, the attenuated neural coding of reward in the medial orbitofrontal cortex and the relation between anhedonia and reduced reward prediction error-signalling in the medial orbitofrontal cortex and ventral striatum likely reflect an impairment in experiencing pleasure from rewarding events as a key mechanism of anhedonia in major depressive disorder. © The Author (2017). Published by Oxford

  18. Remote Monitoring and Instrumentation Strategies for Integral Reactors

    International Nuclear Information System (INIS)

    Upadhyaya, Belle R.; Lish, Matthew R.; Tarver, Rayan A.; Hines, J. Wesley

    2014-01-01

    The University of Tennessee is engaged in research and development projects related to instrumentation and controls for small modular reactors (SMR) and integral pressurized water reactors (iPWR). The approach incorporates the deployment of physics-based models for control design and parameter estimation, development of noncontact sensors for flow monitoring, and placement of sensors to maximize fault detection and isolation. The results of research and development illustrate the feasibility of sensor location in space-constrained environment. Major issues and challenges in I and C design are addressed

  19. Remote Monitoring and Instrumentation Strategies for Integral Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, Belle R.; Lish, Matthew R.; Tarver, Rayan A.; Hines, J. Wesley [University of Tennessee, Knoxville (United States)

    2014-08-15

    The University of Tennessee is engaged in research and development projects related to instrumentation and controls for small modular reactors (SMR) and integral pressurized water reactors (iPWR). The approach incorporates the deployment of physics-based models for control design and parameter estimation, development of noncontact sensors for flow monitoring, and placement of sensors to maximize fault detection and isolation. The results of research and development illustrate the feasibility of sensor location in space-constrained environment. Major issues and challenges in I and C design are addressed.

  20. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  1. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  2. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  3. Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument

    International Nuclear Information System (INIS)

    Lekstrom, M; McLachlan, M A; Husain, S; McComb, D W; Shollock, B A

    2008-01-01

    Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached to a cut-out FIB section using ion beam induced platinum deposition. This article addresses the issues of using an ion beam to monitor the in situ manipulation process as well as approaches that can be used to create stronger platinum welds between two objects, and finally, views on how to limit the extent of ion beam damage to the specimen surface.

  4. Profile variation impact on FIB cross-section metrology

    Science.gov (United States)

    Cordes, Aaron; Bunday, Benjamin; Nadeau, Jim

    2012-03-01

    The focused ion beam (FIB) milling tool is an important component of reference metrology and process characterization, both as a supporting instrument for bulk sample preparation before forwarding to the transmission electron microscope (TEM) and other instruments and as an in situ measurement instrument using angled scanning electron microscopy. As features grow denser, deeper and more demanding, full-profile reference metrology is needed, and this methodology will only grow in importance. Thus, the ability to extract accurate dimensional and profile information out of the crosssectional faces produced by FIB milling is critical. For features that demonstrate perfect symmetry in the plane of the cross section, analyzing images and extracting metrology data are straightforward. However, for industrial materials, symmetry is not a safe assumption: as features shrink, the line edge and sidewall roughness increases as a percentage of the overall feature dimension. Furthermore, with the introduction of more complex architectures such as 3D memory and FinFETs, the areas of greatest interest, such as the intersections of wrap-around gates, cannot be assumed to be symmetrical in any given plane if cut placement is not precisely controlled. Therefore it is important to establish the exact location and repeatability of the cross-section plane, both in terms of coordinate placement and effective angle of the milled surface. To this end, we prepared designed-in line edge roughness samples in the Albany Nanotech facility using SEMATECH's AMAG6 metrology reticle. The samples were thoroughly characterized before being milled by a non-destructive, sidewall-scanning atomic force microscope (AFM). These samples are then milled and measured under varying process and setup parameters using a single-beam FIB with angled SEM. We established methodologies that allow precise alignment of the cut planes of slice-and-view FIB milling to 3D-AFM scan lines to compare repeated sections

  5. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  6. Good practices in normal childbirth: reliability analysis of an instrument by Cronbach's Alpha.

    Science.gov (United States)

    Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia

    2018-01-01

    to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach's Alpha Coefficient for each of the dimensions and for the total instrument. this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. the instrument obtained Cronbach's alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care.

  7. THOR Ion Mass Spectrometer instrument - IMS

    Science.gov (United States)

    Retinò, Alessandro; Kucharek, Harald; Saito, Yoshifumi; Fraenz, Markus; Verdeil, Christophe; Leblanc, Frederic; Techer, Jean-Denis; Jeandet, Alexis; Macri, John; Gaidos, John; Granoff, Mark; Yokota, Shoichiro; Fontaine, Dominique; Berthomier, Matthieu; Delcourt, Dominique; Kistler, Lynn; Galvin, Antoniette; Kasahara, Satoshi; Kronberg, Elena

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. Specifically, THOR will study how turbulent fluctuations at kinetic scales heat and accelerate particles in different turbulent environments within the near-Earth space. To achieve this goal, THOR payload is being designed to measure electromagnetic fields and particle distribution functions with unprecedented resolution and accuracy. Here we present the Ion Mass Spectrometer (IMS) instrument that will measure the full three-dimensional distribution functions of near-Earth main ion species (H+, He+, He++ and O+) at high time resolution (~ 150 ms for H+ , ~ 300 ms for He++) with energy resolution down to ~ 10% in the range 10 eV/q to 30 keV/q and angular resolution ~ 10°. Such high time resolution is achieved by mounting multiple sensors around the spacecraft body, in similar fashion to the MMS/FPI instrument. Each sensor combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCP) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification, discrimination and time-to-digital conversion (TDC). IMS is being designed to address many of THOR science requirements, in particular ion heating and acceleration by turbulent fluctuations in foreshock, shock and magnetosheath regions. The IMS instrument is being designed and will be built by an international consortium of scientific institutes with main hardware contributions from France, USA, Japan and Germany.

  8. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  9. BIRA-IASB Mars activities and instrument capabilities

    Science.gov (United States)

    Drummond, R.; Vandaele, A.-C.; Gillotay, D.; Willame, Y.; Depiesse, C.; Patel, M.; Daerden, F.; Neefs, E.; Ristic, B.; Montmessin, F.

    2009-04-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB) is involved in many areas of Mars exploration, and has been for a long time. Current activities include analysis of SPICAM data, 3D atmospheric modelling as well as instrument development and characterization. This paper will focus on two different instruments to study the Martian atmosphere. UVIS(Patel, 2006) is part of the Exomars payload, that will gather information on the UV levels on the ground, study climatology and sterilisation and also be able to detect organic material in sublimating permafrost. BIRA-IASB is carrying out the characterization and calibration of UVIS. SOIR is an infra-red spectrometer that uses solar occultation measurements to examine major and minor constituents of planetary atmospheres. SOIR is currently orbiting Venus on the VEX spacecraft and has already made several interesting discoveries including the first observations of a new band of a CO2 isotopologue. The data from SOIR-VEX has allowed us to study the instrumental characteristics and perform a sensitivity study(Mahieux, 2008). These properties have been used to simulate realistic SOIR measurements of Mars atmospheric spectra. This work is supported by extensive 3D chemistry modeling work, as described in a paper by Frank Daerden (PS2.9Atmospheres of terrestrial planets). M. R. Patel, et al.,(2006) The UV-VIS spectrometer for the ExoMars mission, in 36th COSPAR Scientific Assembly, Beijing, China. A. Mahieux, et al.,(2008), Appl. Opt. 47 (13), 2252-65.

  10. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  11. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  12. Test instruments used by Journal of Music Therapy authors from 1984-1997.

    Science.gov (United States)

    Gregory, D

    2000-01-01

    Issues of the Journal of Music Therapy from 1984 to 1997 were selected to investigate the application of test instruments in music therapy research. All experimental and descriptive research articles were reviewed to determine if the methodology included test instruments. Other types of measurements-physiological measures, behavioral observations, computerized devices, and self-reports were excluded from the analysis. Test instruments were categorized as either published, unpublished, or researcher-constructed. A test instrument was "published" if, after a search in the "Test Review Locator" of the Buros Mental Measurements Web Site, a reference was found in one or more of the following publications-Mental Measurement Yearbooks, Tests in Print, or Test Critiques. A test was categorized as "unpublished" if the developer was cited in the JMT article but the test was not located in one or more of the above publications. All other test instruments were categorized as researcher-constructed tests designed for the specific study in the article. From 1984-1997, 220 articles were published in JMT. Approximately 83% (n = 183) of the total were experimental or descriptive research studies. Of the 183 articles research studies, 92 (50%) included a test instrument. Reviews of method sections of the 92 articles resulted in a listing of 115 different test instruments. Percentages of researcher-constructed tests, unpublished tests, and published tests were 25%, 35%, and 40% respectively. Lists of tests document the all-encompassing range of client populations and the broad view of human behavior included in the practice of music as therapy. The Journal of Music Therapy, in addition to providing the latest research findings regarding the effectiveness of music as a therapeutic medium, provides an excellent source for updating information about the availability and applicability of test instruments for music therapy clinical practice and training.

  13. Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID: Frequently asked questions

    Directory of Open Access Journals (Sweden)

    Perrier Laure-Lou

    2005-03-01

    Full Text Available Abstract The exponential development of Patient-Reported Outcomes (PRO measures in clinical research has led to the creation of the Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID to facilitate the selection process of PRO measures in clinical research. The project was initiated by Mapi Research Trust in Lyon, France. Initially called QOLID (Quality of Life Instruments Database, the project's purpose was to provide all those involved in health care evaluation with a comprehensive and unique source of information on PRO and HRQOL measures available through the Internet. PROQOLID currently describes more than 470 PRO instruments in a structured format. It is available in two levels, non-subscribers and subscribers, at http://www.proqolid.org. The first level is free of charge and contains 14 categories of basic useful information on the instruments (e.g. author, objective, original language, list of existing translations, etc.. The second level provides significantly more information about the instruments. It includes review copies of over 350 original instruments, 120 user manuals and 350 translations. Most are available in PDF format. This level is only accessible to annual subscribers. PROQOLID is updated in close collaboration with the instruments' authors on a regular basis. Fifty or more new instruments are added to the database annually. Today, all of the major pharmaceutical companies, prestigious institutions (such as the FDA, the NIH's National Cancer Institute, the U.S. Veterans Administration, dozens of universities, public institutions and researchers subscribe to PROQOLID on a yearly basis. More than 800 users per day routinely visit the database.

  14. Using Financial Instruments to Transfer the Information Security Risks

    OpenAIRE

    Pankaj Pandey; Einar Snekkenes

    2016-01-01

    For many individuals and organizations, cyber-insurance is the most practical and only way of handling a major financial impact of an information security event. However, the cyber-insurance market suffers from the problem of information asymmetry, lack of product diversity, illiquidity, high transaction cost, and so on. On the other hand, in theory, capital market-based financial instruments can provide a risk transfer mechanism with the ability to absorb the adverse impact of an information...

  15. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study

    Directory of Open Access Journals (Sweden)

    Ayca Yilmaz

    2017-01-01

    Full Text Available The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9 μm resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  16. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  17. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  18. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  19. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  20. Determination of As by instrumental neutron activation analysis in sectioned hair samples for forensic purposes: chronic or acute poisoning?

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Kofronova, K.

    2011-01-01

    Roč. 287, č. 3 (2011), s. 769-772 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : Instrumental neutron activation analysis * Hair * Arsenic poisoning Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.520, year: 2011

  1. Flexibility and torsional behaviour of rotary nickel-titanium PathFile, RaCe ISO 10, Scout RaCe and stainless steel K-File hand instruments.

    Science.gov (United States)

    Nakagawa, R K L; Alves, J L; Buono, V T L; Bahia, M G A

    2014-03-01

    To assess and compare the flexibility and torsional resistance of PathFile, RaCe ISO 10 and Scout RaCe instruments in relation to stainless steel K-File hand instruments. Rotary PathFile (sizes 13, 16 and 19; .02 taper), Race ISO 10 (size 10; 0.02, 0.04 and 0.06 tapers), Scout RaCe (sizes 10, 15 and 20; 0.02 taper) and hand K-File (sizes 10, 15 and 20; 0.02 taper) instruments were evaluated. Alloy chemical composition, phases present and transformation temperatures were determined for the NiTi instruments. For all instruments, diameters at each millimetre from the tip as well as cross-sectional areas at 3 mm from the tip were measured based on ANSI/ADA Specification No. 101 using image analysis software. Resistance to bending and torsional resistance were determined according to specification ISO 3630-1. Vickers microhardness measurements were also taken in all instruments to assess their strength. Data were analysed using analysis of variance (α = 0.05). The alloys used in the manufacture of the three types of NiTi instruments had approximately the same chemical composition, but the PathFile instruments had a higher Af transformation temperature and contained a small amount of B19' martensite. All instruments had diameter values within the standard tolerance. The bending and torsional resistance values were significantly increased relative to the instrument diameter and cross-sectional area. PathFile instruments were the most flexible and the least torque resistant, whilst the stainless steel instruments were the least flexible although they were more torque resistant than the NiTi instruments. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  3. The blepharospasm disability scale: an instrument for the assessment of functional health in blepharospasm

    NARCIS (Netherlands)

    Lindeboom, R.; de Haan, R.; Aramideh, M.; Speelman, J. D.

    1995-01-01

    Assessment of the functional status in patients with blepharospasm is of major importance for clinical practice and outcome studies. The Blepharospasm Disability Scale (BDS) is specifically directed to measure the disability in these patients. The metric properties of this instrument were evaluated.

  4. The Lund University Checklist for Incipient Exhaustion-a cross-sectional comparison of a new instrument with similar contemporary tools.

    Science.gov (United States)

    Persson, Roger; Österberg, Kai; Viborg, Njördur; Jönsson, Peter; Tenenbaum, Artur

    2016-04-21

    Stress-related health problems (e.g., work-related exhaustion) are a societal concern in many postindustrial countries. Experience suggests that early detection and intervention are crucial in preventing long-term negative consequences. In the present study, we benchmark a new tool for early identification of work-related exhaustion-the Lund University Checklist for Incipient Exhaustion (LUCIE)-against other contextually relevant inventories and two contemporary Swedish screening scales. A cross-sectional population sample (n = 1355) completed: LUCIE, Karolinska Exhaustion Disorder Scale (KEDS), Self-reported Exhaustion Disorder Scale (s-ED), Shirom-Melamed Burnout Questionnaire (SMBQ), Utrecht Work Engagement Scale (UWES-9), Job Content Questionnaire (JCQ), Big Five Inventory (BFI), and items concerning work-family interference and stress in private life. Increasing signs of exhaustion on LUCIE were positively associated with signs of exhaustion on KEDS and s-ED. The prevalence rates were 13.4, 13.8 and 7.8 %, respectively (3.8 % were identified by all three instruments). Increasing signs of exhaustion on LUCIE were also positively associated with reports of burnout, job demands, stress in private life, family-to-work interference and neuroticism as well as negatively associated with reports of job control, job support and work engagement. LUCIE, which is intended to detect pre-stages of ED, exhibits logical and coherent positive relations with KEDS and s-ED as well as other conceptually similar inventories. The results suggest that LUCIE has the potential to detect mild states of exhaustion (possibly representing pre-stages to ED) that if not brought to the attention of the healthcare system and treated, may develop in to ED. The prospective validity remains to be evaluated.

  5. Measuring Medical Housestaff Teamwork Performance Using Multiple Direct Observation Instruments: Comparing Apples and Apples.

    Science.gov (United States)

    Weingart, Saul N; Yaghi, Omar; Wetherell, Matthew; Sweeney, Megan

    2018-04-10

    To examine the composition and concordance of existing instruments used to assess medical teams' performance. A trained observer joined 20 internal medicine housestaff teams for morning work rounds at Tufts Medical Center, a 415-bed Boston teaching hospital, from October through December 2015. The observer rated each team's performance using 9 teamwork observation instruments that examined domains including team structure, leadership, situation monitoring, mutual support, and communication. Observations recorded on paper forms were stored electronically. Scores were normalized from 1 (low) to 5 (high) to account for different rating scales. Overall mean scores were calculated and graphed; weighted scores adjusted for the number of items in each teamwork domain. Teamwork scores were analyzed using t-tests, pair-wise correlations, and the Kruskal-Wallis statistic, and team performance was compared across instruments by domain. The 9 tools incorporated 5 major domains, with 5-35 items per instrument for a total of 161 items per observation session. In weighted and unweighted analyses, the overall teamwork performance score for a given team on a given day varied by instrument. While all of the tools identified the same low outlier, high performers on some instruments were low performers on others. Inconsistent scores for a given team across instruments persisted in domain-level analyses. There was substantial variation in the rating of individual teams assessed concurrently by a single observer using multiple instruments. Since existing teamwork observation tools do not yield concordant assessments, researchers should create better tools for measuring teamwork performance.

  6. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users

    Institute of Scientific and Technical Information of China (English)

    Sandra M. Prentiss; David R. Friedland; Tanner Fullmer; Alison Crane; Timothy Stoddard; Christina L. Runge

    2016-01-01

    Objective:To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) lis-teners. Methods: This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experi-ments 2 and 3 assessed the ability to discriminate the different stimuli. Results:Normal hearing subjects performed better than CI subjects in all instrument identifi-cation tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI pop-ulation, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination perfor-mance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Conclusions:Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  7. The Top-of-Instrument corrections for nuclei with AMS on the Space Station

    Science.gov (United States)

    Ferris, N. G.; Heil, M.

    2018-05-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance, high precision magnetic spectrometer on the International Space Station (ISS). The top-of-instrument correction for nuclei flux measurements with AMS accounts for backgrounds due to the fragmentation of nuclei with higher charge. Upon entry in the detector, nuclei may interact with AMS materials and split into fragments of lower charge based on their cross-section. The redundancy of charge measurements along the particle trajectory with AMS allows for the determination of inelastic interactions and for the selection of high purity nuclei samples with small uncertainties. The top-of-instrument corrections for nuclei with 2 < Z ≤ 6 are presented.

  8. Validation of Atmosphere/Ionosphere Signals Associated with Major Earthquakes by Multi-Instrument Space-Borne and Ground Observations

    Science.gov (United States)

    Ouzounov, Dimitar; Pulinets, Sergey; Hattori, Katsumi; Parrot, Michel; Liu, J. Y.; Yang, T. F.; Arellano-Baeza, Alonso; Kafatos, M.; Taylor, Patrick

    2012-01-01

    ) eahquakes. Results have revealed the presence of related variations of these parameters implying their connection with the earthquake process. The second phase (B) of this validation included 102 major earthquakes (M>5.9) in Taiwan and Japan. We have found anomalous behavior before all of these events with no false negatives. False alarm ratio for false positives is less then 10% and has been calculated for the same month of the earthquake occurrence for the entire period of analysis (2003-2009). The commonalities for detecting atmospheric/ionospheric anomalies are: i.) Regularly appearance over regions of maximum stress (i.e., along plate boundaries); ii.) Anomaly existence over land and sea; and iii) association with M>5.9 earthquakes not deeper than 100km. Due to their long duration over the same region these anomalies are not consistent with a meteorological origin. Our initial results from the ISTF validation of multi-instrument space-borne and ground observations show a systematic appearance of atmospheric anomalies near the epicentral area, one to seven (average) days prior to the largest earthquakes, and suggest that it could be explained by a coupling process between the observed physical parameters and the pre-earthquake preparation processes.

  9. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  10. Performance profiles of major energy producers 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs.

  11. Performance profiles of major energy producers 1996

    International Nuclear Information System (INIS)

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs

  12. Review of decametric radio astronomy - instruments and science

    International Nuclear Information System (INIS)

    Erickson, W.C.; Cane, H.V.

    1987-01-01

    The techniques and instruments used in Galactic and extragalactic radio astronomy at dkm wavelengths are surveyed, and typical results are summarized. Consideration is given to the large specialized phased arrays used for early surveys, the use of wideband elements to increase frequency agility, experimental VLBI observations, and limitations on ground-based observations below about 10 MHz (where the proposed LF Space Array, with resolution 0.5-5 arcmin, could make a major contribution). Observations discussed cover the Galactic center, the Galactic background radiation, SNRs, compact Galactic sources, the ISM, and large extragalactic sources. 38 references

  13. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how to mea...... was prevalent. It is uncertain whether development of a single 'all-inclusive' model for assessing integrated care is desirable. We emphasise the continuing need for validated instruments embedded in theoretical contexts.......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  14. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  15. Aircraft Instrument, Fire Protection, Warning, Communication, Navigation and Cabin Atmosphere Control System (Course Outline), Aviation Mechanics 3 (Air Frame): 9067.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with manipulative skills and theoretical knowledge concerning aircraft instrument systems like major flight and engine instruments; fire protection and fire fighting systems; warning systems and navigation systems; aircraft cabin control systems, such as…

  16. Studies on Section XI ultrasonic repeatability

    International Nuclear Information System (INIS)

    Jamison, T.D.; McDearman, W.R.

    1981-05-01

    A block representative of a nuclear component has been welded containing intentional defects. Acoustic emission data taken during the welding correlate well with ultrasonic data. Repetitive ultrasonic examinations have been performed by skilled operators using a procedure based on that desribed in ASME Section XI. These examinations were performed by different examination teams using different ultrasonic equipment in such a manner that the effects on the repeatability of the ultrasonic test method caused by the operator and by the use of different equipment could be estimated. It was tentatively concluded that when considering a large number of inspections: (1) there is no significant difference in indication sizing between operators, and (2) there is a significant difference in amplitude and defect sizing when instruments having different, Code acceptable operating characteristics are used. It was determined that the Section XI sizing parameters follow a bivariate normal distribution. Data derived from ultrasonically and physically sizing indications in nuclear components during farication show that the Section XI technique tends to overestimate the size of the reflectors

  17. Functional capabilities of the breadboard model of SIDRA satellite-borne instrument

    International Nuclear Information System (INIS)

    Dudnik, O.V.; Kurbatov, E.V.; Titov, K.G.; Prieto, M.; Sanchez, S.; Sylwester, J.; Gburek, S.; Podgorski, P.

    2013-01-01

    This paper presents the structure, principles of operation and functional capabilities of the breadboard model of SIDRA compact satellite-borne instrument. SIDRA is intended for monitoring fluxes of high-energy charged particles under outer-space conditions. We present the reasons to develop a particle spectrometer and we list the main objectives to be achieved with the help of this instrument. The paper describes the major specifications of the analog and digital signal processing units of the breadboard model. A specially designed and developed data processing module based on the Actel ProAsic3E A3PE3000 FPGA is presented and compared with the all-in one digital processing signal board based on the Xilinx Spartan 3 XC3S1500 FPGA.

  18. Oil majors under states pressure: two examples in the Caspian basin

    International Nuclear Information System (INIS)

    Lussac, Samuel; Raballand, Gael

    2011-01-01

    All over the world, and especially in developing countries, governments strive to strengthen national oil companies over oil and gas majors. The Caspian, and notably Azerbaijan and Kazakhstan, is not an exception to this current trend. This article sheds light on the leverages both Azerbaijani and Kazakhstani governments have used to increase pressure over oil and gas multinationals. In a first step, they both established a publicly-owned integrated company managed by the presidential entourage. Then, Azerbaijan and Kazakhstan have applied various instruments. Baku has sought to increase its own oil production to decrease the role of majors while Astana has preferred to use ecological, fiscal, legal and logistical leverages. However, in both cases, the outcome has been rather similar since the increasing pressure over majors has not necessarily led to benefit local populations

  19. Instrument air system - Aging impact on system availability

    International Nuclear Information System (INIS)

    Villaran, M.; Subudhi, M.

    1989-01-01

    As part of ongoing efforts to understand and manage the effects of aging in nuclear power plants, an aging assessment was performed for the Instrument Air (IA) system, a system that has been the subject of much scrutiny in recent years. Despite its non-safety classification, instrument air has been a factor in a number of potentially serious events. This report presents the results of the assessment and discusses the impact of instrument air system aging on system availability and plant safety. This work was performed for the US Nuclear Regulatory Commission (NRC) as part of the Nuclear Plant Aging Research (NPAR) program. To perform the complex task of analyzing an entire system, the Aging and Life Extension Assessment Program (ALEAP) System Level Plan was developed by Brookhaven National Laboratory and applied successfully in previous system aging studies. The work presented herein was performed using two parallel work paths, as described in the ALEAP plant. One path used deterministic techniques to assess the impact of aging on compressed air system performance, while the second path used probabilistic methods. Results from both paths then were used to characterize aging in the instrument air system. Some conclusions from this work are: compressors, air system valves, and air dryers were found to make up the majority of failures; the effectiveness and quantity of preventive maintenance devoted to a component significantly affected the amount of failures experienced; review of compressed air system designs and studies using a PRA-based system model revealed that the redundancy of key components (compressors, dryers, IA/SA crossconnect valve) was an important factor in system availability; total loss of air events are uncommon

  20. Instrumentation for the study of low emittance tuning and beam dynamics at CESR

    Science.gov (United States)

    Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.

    2017-11-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.

  1. Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, nathaniel R.; Baggott, Renee S.; Singh, Upendra N.; Kavaya, Michael J.

    2004-01-01

    Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

  2. Simulation of a major tokamak disruption

    International Nuclear Information System (INIS)

    White, R.B.; Monticello, D.A.; Rosenbluth, M.N.

    1977-08-01

    It is known that the internal tokamak disruption leads to a current profile which is flattened inside the surface where the safety factor equals unity. It is shown that such a profile can lead to m = 2 magnetic islands which grow to fill a substantial part of the tokamak cross section in a time consistent with the observations of the major disruption

  3. Testing for Unit Roots in Small Panels with Short-run and Long-run Cross-sectional Dependencies

    OpenAIRE

    Yoosoon Chang; Wonho Song

    2009-01-01

    An IV approach, using as instruments non-linear transformations of the lagged levels, is explored to test for unit roots in panels with general dependency and heterogeneity across cross-sectional units. We allow not only for the cross-sectional dependencies of innovations, but also for the presence of co-integration across cross-sectional levels. Unbalanced panels and panels with differing individual short-run dynamics and cross-sectionally related dynamics are also permitted. We also more ca...

  4. Knowledge, beliefs and experiences of a cross section of mothers in ...

    African Journals Online (AJOL)

    ... experiences of a cross-section of mothers in Port Harcourt about teething. Methods: The study was conducted using a structured, anonymous open and close-ended questionnaire distributed among randomly selected female staff of University of Port Harcourt as instrument for data collection. The data was analyzed using ...

  5. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  6. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  7. Under sodium reliability tests on core components and in-core instrumentation

    International Nuclear Information System (INIS)

    Ruppert, E.; Stehle, H.; Vinzens, K.

    1977-01-01

    A sodium test facility for fast breeder core components (AKB), built by INTERATOM at Bensberg, has been operating since 1971 to test fuel dummies and blanket elements as well as absorber elements under simulated normal and extreme reactor conditions. Individual full-scale fuel or blanket elements and arrays of seven elements, modelling a section of the SNR-300 reactor core, have been tested under a wide range of sodium mass flow and isothermal test conditions up to 925K as well as under cyclic changed temperature transients. Besides endurance testing of the core components a special sodium and high-temperature instrumentation is provided to investigate thermohydraulic and vibrational behaviour of the test objects. During all test periods the main subassembly characteristics could be reproduced and the reliability of the instrumentation could be proven. (orig.) [de

  8. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  9. Drugs as instruments: a new framework for non-addictive psychoactive drug use.

    Science.gov (United States)

    Müller, Christian P; Schumann, Gunter

    2011-12-01

    Most people who are regular consumers of psychoactive drugs are not drug addicts, nor will they ever become addicts. In neurobiological theories, non-addictive drug consumption is acknowledged only as a "necessary" prerequisite for addiction, but not as a stable and widespread behavior in its own right. This target article proposes a new neurobiological framework theory for non-addictive psychoactive drug consumption, introducing the concept of "drug instrumentalization." Psychoactive drugs are consumed for their effects on mental states. Humans are able to learn that mental states can be changed on purpose by drugs, in order to facilitate other, non-drug-related behaviors. We discuss specific "instrumentalization goals" and outline neurobiological mechanisms of how major classes of psychoactive drugs change mental states and serve non-drug-related behaviors. We argue that drug instrumentalization behavior may provide a functional adaptation to modern environments based on a historical selection for learning mechanisms that allow the dynamic modification of consummatory behavior. It is assumed that in order to effectively instrumentalize psychoactive drugs, the establishment of and retrieval from a drug memory is required. Here, we propose a new classification of different drug memory subtypes and discuss how they interact during drug instrumentalization learning and retrieval. Understanding the everyday utility and the learning mechanisms of non-addictive psychotropic drug use may help to prevent abuse and the transition to drug addiction in the future.

  10. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  11. Beliefs of Applied Studio Faculty on Desirable Traits of Prospective Music Education Majors

    Science.gov (United States)

    Royston, Natalie Steele; Springer, D. Gregory

    2017-01-01

    The purpose of this study was to examine the beliefs of applied music faculty on desirable traits of prospective music education majors. Respondents (N = 326), who were sampled from 73 National Association of Schools of Music-accredited institutions in the United States, completed a survey instrument developed to determine the characteristics of…

  12. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  13. 7 CFR 3052.520 - Major program determination.

    Science.gov (United States)

    2010-01-01

    ... Auditors § 3052.520 Major program determination. (a) General. The auditor shall use a risk-based approach... section shall be followed. (b) Step 1. (1) The auditor shall identify the larger Federal programs, which... providing loans significantly affects the number or size of Type A programs, the auditor shall consider this...

  14. Lumbar lordosis restoration following single-level instrumented fusion comparing 4 commonly used techniques.

    Science.gov (United States)

    Dimar, John R; Glassman, Steven D; Vemuri, Venu M; Esterberg, Justin L; Howard, Jennifer M; Carreon, Leah Y

    2011-11-09

    A major sequelae of lumbar fusion is acceleration of adjacent-level degeneration due to decreased lumbar lordosis. We evaluated the effectiveness of 4 common fusion techniques in restoring lordosis: instrumented posterolateral fusion, translumbar interbody fusion, anteroposterior fusion with posterior instrumentation, and anterior interbody fusion with lordotic threaded (LT) cages (Medtronic Sofamor Danek, Memphis, Tennessee). Radiographs were measured preoperatively, immediately postoperatively, and a minimum of 6 months postoperatively. Parameters measured included anterior and posterior disk space height, lumbar lordosis from L3 to S1, and surgical level lordosis.No significant difference in demographics existed among the 4 groups. All preoperative parameters were similar among the 4 groups. Lumbar lordosis at final follow-up showed no difference between the anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cage groups, although the posterolateral fusion group showed a significant loss of lordosis (-10°) (Plordosis and showed maintenance of anterior and posterior disk space height postoperatively compared with the other groups. Instrumented posterolateral fusion produces a greater loss of lordosis compared with anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cages. Maintenance of lordosis and anterior and posterior disk space height is significantly better with anterior interbody fusion with LT cages. Copyright 2011, SLACK Incorporated.

  15. 5 CFR 532.267 - Special wage schedules for aircraft, electronic, and optical instrument overhaul and repair...

    Science.gov (United States)

    2010-01-01

    ... manufacturing. 334418 Printed circuit assembly (electronic assembly) manufacturing. 334419 Other electronic..., electronic, and optical instrument overhaul and repair positions in Puerto Rico. 532.267 Section 532.267 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS...

  16. Neutron cross section standards for the energy region above 20 MeV

    International Nuclear Information System (INIS)

    1991-01-01

    These proceedings of a specialists' meeting on Neutron cross section standards for the energy region above 20 MeV are divided into 6 sessions bearing on: - session 1: status of the date base for (n-p) scattering (2 conferences) - session 2: status of nucleon-nucleon phase shift calculations (1 conference) - session 3: recent and planned experimental work on n-p cross section measurements and facilities (7 conferences) - session 4: Instruments for utilizing the H (n.n) standard for neutron fluence measurement (4 conferences) - session 5: proposal for other neutron cross-section standards (4 conferences) - session 6: monitor reactions for radiation dosimetry (3 conferences)

  17. The strategy for intelligent integrated instrumentation and control system development

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Shik

    1995-01-01

    All of the nuclear power plants in Korea are operating with analog instrumentation and control ( I and C) equipment which are increasingly faced with frequent troubles, obsolescence and high maintenance expenses. Electrical and computer technology has improved rapidly in recent years and has been applied to other industries. So it is strongly recommended we adopt modern digital and computer technology to improve plant safety and availability. The advanced I and C system, namely, Integrated Intelligent Instrumentation and Control System (I 3 Cs) will be developed for beyond the next generation nuclear power plant. I 3 CS consists of three major parts, the advanced compact workstation, distributed digital control and protection system including Automatic Start-up/Shutdown Intelligent Control System (ASICS) and the computer-based alarm processing and operator support system, namely, Diagnosis, Response, and operator Aid Management System (DREAMS)

  18. [Laparoscopic single patient use instruments: expensive outsourcing of product quality?].

    Science.gov (United States)

    von Eiff, W; Ziegenbein, R

    2000-01-01

    The supply of medical goods is an important critical success factor in German hospitals. One major managerial area in the procurement concerns the decision between single patient use (SPU) and multiple patient use (MPU) products. Especially laparoscopic instruments which are generally expensive are a field of interest for decision makers. Due to a lack of quantifiable factors describing the two different forms of supply alternatives with their effects on effectivity and efficiency of the procurement process and the final use are often not taken into account. Since it is expected that in the future more and more laparoscopic instruments will be needed there is a necessity for finding a concept allowing the identification of the "right" product. The Center for Hospital Management (CKM) has the aim to develop a corresponding approach but needs the help of the reader.

  19. Determination of Major and Minor Elements in the Code River Sediments

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno; Bambang Irianto

    2007-01-01

    Analyze major and minor elements in the Code river sediments has been done. The aim of this research is to determine the concentration of major and minor elements in the Code river sediments from upstream to downstream. The instrument used were X-ray Fluorescence using Si(Li) detector. The results show that major elements were Fe (1.66 ± 0.1% - 4.20 ± 0.7%) and Ca (4.43 ± 0.6% - 9.08 ± 1.3%); while minor elements were Ba (178.791 ± 21.1 ppm - 616.56 ± 59.4 ppm); Sr (148.22 ± 21.9 ppm - 410.25 ± 30.5 ppm); and Zr (9.71 ± 1.1 ppm - 22.11 ± 3.4 ppm). ANAVA method (confidence level of α 0.05 ) for statistic test was used. It was showed that there were significant influence of the sampling location difference on the concentration of major and minor elements in the sediment samples. (author)

  20. Is playing string or wind musical instruments a risk factor for temporomandibular dysfunction? A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Alessandro Leite Cavalcanti

    2017-11-01

    Full Text Available Aim. Medical problems specifically affecting professional musicians are commonly mentioned in the literature. The present study is aimed to evaluate, through a systematic review, the possible association between the practice of string with bow and wind musical instruments and the occurrence of Temporomandibular Dysfunction (TMD. Methods. The search for articles was conducted in PubMed/Medline, Web of Science, Scopus, Lilacs, Cochrane Library, and Open Gray databases, and there was no restriction on language or date of publication. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA guidelines were followed. The MeSH terms used were: “music”; “temporomandibular joint”; “temporomandibular joint disorders”; “temporomandibular joint dysfunction syndrome”; and “occupational diseases”. Cross-sectional studies, case-control, cohort and clinical trials were included that involved the practice of string with bow and wind musical instruments and the occurrence of Temporomandibular Dysfunction (TMD. Articles were previously selected by title and abstract. Qualitative evaluation was done through the Newcastle-Ottawa Scale. Results. The literature search identified 732 studies, of which 10 met the inclusion criteria, nine of them cross-sectional studies and one a clinical intervention study. The TMD prevalence ranged from 47.0% to 89.0%. Recruitment of participants took place in professional schools and orchestras, and in bands of professional musicians. All studies reported associations between TMD and the practice of musical instruments, and violinists presented higher prevalence rates when compared to other instrument groups. Conclusion. All studies pointed to a possible association between TMD and the practice of string and wind musical instruments. More longitudinal and clinical trials studies are needed to verify any possible interrelationship.

  1. Power station instrumentation

    International Nuclear Information System (INIS)

    Jervis, M.W.

    1993-01-01

    Power stations are characterized by a wide variety of mechanical and electrical plant operating with structures, liquids and gases working at high pressures and temperatures and with large mass flows. The voltages and currents are also the highest that occur in most industries. In order to achieve maximum economy, the plant is operated with relatively small margins from conditions that can cause rapid plant damage, safety implications, and very high financial penalties. In common with other process industries, power stations depend heavily on control and instrumentation. These systems have become particularly significant, in the cost-conscious privatized environment, for providing the means to implement the automation implicit in maintaining safety standards, improving generation efficiency and reducing operating manpower costs. This book is for professional instrumentation engineers who need to known about their use in power stations and power station engineers requiring information about the principles and choice of instrumentation available. There are 8 chapters; chapter 4 on instrumentation for nuclear steam supply systems is indexed separately. (Author)

  2. The influence of perceived prejudice on willingness to be a nurse via the mediating effect of satisfaction with major: A cross-sectional study among chinese male nursing students.

    Science.gov (United States)

    Feng, Danjun; Zhao, Wenjing; Shen, Shiyu; Chen, Jieru; Li, Lu

    2016-07-01

    The gender-based stereotype of nursing as a female profession has been a large obstacle to men entering the nursing profession. However, there is little quantitative research on the influence of prejudice induced by this stereotype on male nursing students' willingness to be nurses. To examine the effect of perceived prejudice on willingness to be a nurse via the mediating effect of satisfaction with major among Chinese male nursing students. A cross-sectional survey was used. Four hundred and sixty male nursing students who were enrolled either in bachelor's programs in universities or advanced diploma programs in colleges in Jinan, China, were surveyed using questionnaires measuring perceived prejudice, satisfaction with major, and willingness to be a nurse. Structural equation modeling with bias-corrected bootstrapping was employed to determine the influence of perceived prejudice on willingness to be a nurse with major satisfaction as a mediator. Male students who were in an advanced diploma nursing program and those for whom nursing was the first-choice major reported significantly less perceived prejudice, greater satisfaction with major, and greater willingness to be nurses than did those in a bachelor's nursing program and those for whom nursing was not the first-choice major, respectively. Moreover, although perceived prejudice had no significant direct effect on willingness to be a nurse (β=0.07, p>0.05), it did have a strong indirect effect (full mediation) via satisfaction with major (β=-0.59, pnursing students' willingness to be nurses via the full mediating effect of satisfaction with major. Because this obsolete stereotype of nursing as a female occupation gives birth to prejudice against male nursing students, effective measures should be taken to change this stereotype to recruit more men as nursing staff. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    Science.gov (United States)

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  4. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  5. Instrument Psychometrics: Parental Satisfaction and Quality Indicators of Perinatal Palliative Care.

    Science.gov (United States)

    Wool, Charlotte

    2015-10-01

    Despite a life-limiting fetal diagnosis, prenatal attachment often occurs in varying degrees resulting in role identification by an individual as a parent. Parents recognize quality care and report their satisfaction when interfacing with health care providers. The aim was to test an instrument measuring parental satisfaction and quality indicators with parents electing to continue a pregnancy after learning of a life-limiting fetal diagnosis. A cross sectional survey design gathered data using a computer-mediated platform. Subjects were parents (n=405) who opted to continue a pregnancy affected by a life-limiting diagnosis. Factor analysis using principal component analysis with Varimax rotation was used to validate the instrument, evaluate components, and summarize the explained variance achieved among quality indicator items. The Prenatal Scale was reduced to 37 items with a three-component solution explaining 66.19% of the variance and internal consistency reliability of 0.98. The Intrapartum Scale included 37 items with a four-component solution explaining 66.93% of the variance and a Cronbach α of 0.977. The Postnatal Scale was reduced to 44 items with a six-component solution explaining 67.48% of the variance. Internal consistency reliability was 0.975. The Parental Satisfaction and Quality Indicators of Perinatal Palliative Care Instrument is a valid and reliable measure for parent-reported quality care and satisfaction. Use of this instrument will enable clinicians and researchers to measure quality indicators and parental satisfaction. The instrument is useful for assessing, analyzing, and reporting data on quality for care delivered during the prenatal, intrapartum, and postnatal periods.

  6. Data acquisition system for the neutron scattering instruments at the intense pulsed neutron source

    International Nuclear Information System (INIS)

    Crawford, R.K.; Daly, R.T.; Haumann, J.R.; Hitterman, R.L.; Morgan, C.B.; Ostrowski, G.E.; Worlton, T.G.

    1981-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a major new user-oriented facility which is now coming on line for basic research in neutron scattering and neutron radiation damage. This paper describes the data-acquisition system which will handle data acquisition and instrument control for the time-of-flight neutron-scattering instruments at IPNS. This discussion covers the scientific and operational requirements for this system, and the system architecture that was chosen to satisfy these requirements. It also provides an overview of the current system implementation including brief descriptions of the hardware and software which have been developed

  7. A review of modern instrumental methods of elemental analysis of petroleum related material. Part 2

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1991-01-01

    In this paper a review is presented of the state of the art in elemental analysis of petroleum-related materials (crude oil, gasoline, additives, and lubricants) using modern instrumental analysis techniques. The major instrumental techniques used for elemental analysis of petroleum products include atomic absorption spectrometry (both with flame and with graphite furnace atomizer), inductively coupled plasma atomic emission spectrometry, ion chromatography, microelemental methods, neutron activation, spark source mass spectrometry, and x-ray fluorescence. Each of these techniques is compared for its advantages, disadvantages, and typical applications in the petroleum field

  8. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  9. Effects of epidural analgesia on labor length, instrumental delivery, and neonatal short-term outcome.

    Science.gov (United States)

    Hasegawa, Junichi; Farina, Antonio; Turchi, Giovanni; Hasegawa, Yuko; Zanello, Margherita; Baroncini, Simonetta

    2013-02-01

    We aimed to clarify whether the short-term adverse neonatal outcomes associated with epidural analgesia are due to the epidural analgesia itself or to the instrumental delivery. A retrospective case-control study was conducted to evaluate the relationship between epidural analgesia, labor length, and perinatal outcomes. A total of 350 pregnant women at term who delivered under epidural analgesia (cases) were compared with 1400 patients without epidural analgesia (controls). Vacuum extraction (6.5 vs. 2.9 %) and cesarean section (19.9 vs. 11.1 %) were more frequently performed in the cases than controls (p neonatal variables stratified by mode of delivery were not different in cases and controls, except for a slightly lower umbilical arterial pH in spontaneous delivery for the cases group. However, the Apgar scores and umbilical arterial pH were significantly lower in the neonates delivered by vacuum extraction compared with those in the neonates delivered by spontaneous delivery or cesarean section, regardless of whether epidural analgesia was performed. A multivariable analysis showed that vacuum extraction much more consistently affected the arterial pH than the analgesia itself (the β coefficients were -0.036 for epidural analgesia vs. -0.050 for vacuum extraction). Epidural analgesia was associated with slowly progressing labor, thus resulting in an increased rate of instrumental delivery. This instrumental delivery appears to adversely affect the neonatal outcomes more strongly than the analgesia itself.

  10. Relationship between the burden of major periodontal bacteria and serum lipid profile in a cross-sectional Japanese study.

    Science.gov (United States)

    Choi, Youn-Hee; Kosaka, Takayuki; Ojima, Miki; Sekine, Shinichi; Kokubo, Yoshihiro; Watanabe, Makoto; Miyamoto, Yoshihiro; Ono, Takahiro; Amano, Atsuo

    2018-05-04

    The association of periodontal bacteria with lipid profile alteration remains largely unknown, although it has been suggested that chronic periodontitis increases the atherosclerotic risk. This cross-sectional study investigated the relationship between the prevalence and total burden of periodontal bacteria and serum lipid profile. Saliva from enrolled participants was collected to detect 4 major periodontal bacteria (Porphyromonas gingivalis, Treponema denticola, Tannerella forsythia, and Prevotella intermedia) using Polymerase Chain Reaction method. High-density lipoprotein (HDL) cholesterol, triglycerides (TG), and low-density lipoprotein cholesterol were assessed using blood samples. We compared the averages of each lipid in association with the prevalence of each bacterial species, their burden (low, moderate, and high), and the combination of bacterial burden and periodontal status, defined as periodontitis, using the Community Periodontal Index, after adjustment for other potential confounding factors, by employing general linear models with least square means. A total of 385 Japanese individuals (176 men, 209 women; mean age 69.2 years) were enrolled. The number of bacterial species and their co-existence with periodontitis were significantly related to a decrease in HDL (p for trend Periodontal bacterial burden is suggested to be independently involved in lowering serum HDL level. Our findings suggest that bacterial tests in a clinical setting could be a useful approach for predicting the risk of HDL metabolism dysregulation.

  11. A Survey Study of Autonomous Learning by Chinese Non-English Major Post-Graduates

    Science.gov (United States)

    Xu, Jianping

    2009-01-01

    This thesis reports a survey study of the autonomous L2 learning by 100 first-year non-English-major Chinese post-graduates via the instruments of a questionnaire and semi-structured interview after the questionnaire. It attends to address the following research question: To what extent do Chinese postgraduate students conduct autonomous L2…

  12. The importance of fungi and mycology for addressing major global challenges*

    OpenAIRE

    Lange, Lene

    2014-01-01

    In the new bioeconomy, fungi play a very important role in addressing major global challenges, being instrumental for improved resource efficiency, making renewable substitutes for products from fossil resources, upgrading waste streams to valuable food and feed ingredients, counteracting life-style diseases and antibiotic resistance through strengthening the gut biota, making crop plants more robust to survive climate change conditions, and functioning as host organisms for production of new...

  13. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  14. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  15. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  16. Confucian "Creatio in Situ"--Philosophical Resource for a Theory of Creativity in Instrumental Music Education

    Science.gov (United States)

    Tan, Leonard

    2016-01-01

    In this philosophical essay, I propose a theory of creativity for instrumental music education inspired by Confucian "creatio in situ" ("situational creativity"). Through an analysis of three major texts from classical Confucianism--the "Analects," the "Zhongyong" ("Doctrine of the Mean"), and the…

  17. The Lund University Checklist for Incipient Exhaustion–a cross–sectional comparison of a new instrument with similar contemporary tools

    Directory of Open Access Journals (Sweden)

    Roger Persson

    2016-04-01

    Full Text Available Abstract Background Stress-related health problems (e.g., work-related exhaustion are a societal concern in many postindustrial countries. Experience suggests that early detection and intervention are crucial in preventing long-term negative consequences. In the present study, we benchmark a new tool for early identification of work-related exhaustion–the Lund University Checklist for Incipient Exhaustion (LUCIE–against other contextually relevant inventories and two contemporary Swedish screening scales. Methods A cross-sectional population sample (n = 1355 completed: LUCIE, Karolinska Exhaustion Disorder Scale (KEDS, Self-reported Exhaustion Disorder Scale (s-ED, Shirom-Melamed Burnout Questionnaire (SMBQ, Utrecht Work Engagement Scale (UWES-9, Job Content Questionnaire (JCQ, Big Five Inventory (BFI, and items concerning work-family interference and stress in private life. Results Increasing signs of exhaustion on LUCIE were positively associated with signs of exhaustion on KEDS and s-ED. The prevalence rates were 13.4, 13.8 and 7.8 %, respectively (3.8 % were identified by all three instruments. Increasing signs of exhaustion on LUCIE were also positively associated with reports of burnout, job demands, stress in private life, family-to-work interference and neuroticism as well as negatively associated with reports of job control, job support and work engagement. Conclusions LUCIE, which is intended to detect pre-stages of ED, exhibits logical and coherent positive relations with KEDS and s-ED as well as other conceptually similar inventories. The results suggest that LUCIE has the potential to detect mild states of exhaustion (possibly representing pre-stages to ED that if not brought to the attention of the healthcare system and treated, may develop in to ED. The prospective validity remains to be evaluated.

  18. Ursa Major: ot losya do medvedya %t Ursa Major: from elk to bear

    Science.gov (United States)

    Lushnikova, A. V.

    In the article material from various cultural and linguistic sources (Indo-European - Slavic, Indo-Iranian; Uralo-Altaic, Tungus, Ancient Egyptian, Babylonian) is used in order to trace up the chronology of the designation of Ursa Majopr, a constellation which has been playing an important role for people different regions since ancient times. It was used for observing of the visible yearly motion of the Sun, for working out seasonal changes; being a circumpolar and non-hiding behind the horizon it has been perceived as a symbol of immortality, its peculiar positional change during a year lay down in plot of the Uralo-Siberian myths about a cosmic hunt for the Elk, myths about deluge. Data from Uralo-Siberian mythology are analyzed. Designations of Ursa Major in the form of a horned hoofed animal such as elk, deer, cow (Uralo-Altaic, Tungus, Slavic, Indo-Iranian languages; Ancient Greece, Crete, Ancient Egypt) and connected with it (or derived from it) denominations and images of "enclosed space" - "vehicle for travelling and carrying goods" (a wagon, a boat) - "instrument for hunting-fishing, a ritual thing" - "household construction" are taken in consideration. The conclusion is made that the transition of the Ursa Major designation from elk to bear could follow the general tendency to shift from so-called matriarchy to patriarchy, to substitute female deities with male ones, which was reflected "in the rise" of the predatory animal cults (not earlier than II mil. B.C.). To prove this, lexical examples of resemblance and coincidences in designation of homed hoofed (elk, deer) and predatory (bear, wolf) animals should be analyzed. Such a goal-directed investigation of the chronology of Ursa Major designations has never been carried out.

  19. Innovation Policy of the European Union: Concept Strategic Update and Instruments Improvement

    Directory of Open Access Journals (Sweden)

    Belal Hassouna

    2013-01-01

    Full Text Available The article characterizes formation of EU innovation policy and its conceptual update, which has strategic character and is concerned with the social and economic model change, determines differences between EU innovation policy and national politics and the forms of its implementation, detects major changes of EU innovation policy instruments, which were the result of support concept and innovation regulations change.

  20. Instrument setpoints and data gathering techniques

    International Nuclear Information System (INIS)

    Leong, J.L.; Ornellas, R.P.; Atkinson, J.L.; Gross, R.S.

    1994-01-01

    Setpoint calculation project sizes vary greatly depending upon the level of effort required and can generally be classified as small or large depending on the number of setpoint calculations required. Small projects usually consist of new system upgrades, power uprates, and the utility's response to industry wide issues and concerns, and require between 10 and 120 setpoint calculations. Large projects usually involve design basis reconstitutions and the complete recalculating of all setpoints prioritized on system or safety related bases. Both large and small project schedules are usually directly tied to Nuclear Regulatory Commission (NRC) commitment dates and it is not uncommon for a large project to take 2 to 3 years to complete. Setpoint calculation projects have historically been performed by the brute force technique employing a variety of methodologies. The brute force technique typically employed today involves putting together a project team large enough to perform all the scheduled setpoint calculations. Setpoint calculations vary in size and complexity and, therefore, may require a wide range of man-hours of a qualified instrument setpoint engineer's time to perform instrument input data retrieval, resolve conflicting input data values, and complete the calculation. The actual time to perform the setpoint calculation using a computer program to calculate results is relatively small in comparison with the time required for data collection and the preparation of supporting documentation. Three major issues have traditionally plagued setpoint calculation projects: data collection; methodology; and incomplete and inconsistent calculations. These traditional problems are addressed and an innovative solution to performing instrument setpoint calculation projects is presented. Through the use of the POWRTRAK database and powerful computer software programs, a new solution to an old and persistent industry challenge is established

  1. College Students' Evaluation of Effective Teaching: Developing an Instrument and Assessing Its Psychometric Properties

    Science.gov (United States)

    Dodeen, Hamzeh

    2013-01-01

    Students' evaluations of teaching (SETs) are currently the most commonly used method for evaluating teaching effectiveness in higher education institutions. They aid in evaluating the quality of faculty teaching and provide useful information for administrators, faculty, and students. The majority of SET instruments were developed based on faculty…

  2. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  3. Work-nonwork interference: Preliminary results on the psychometric properties of a new instrument

    Directory of Open Access Journals (Sweden)

    Eileen Koekemoer

    2010-11-01

    Research purpose: The objectives of this study were to investigate the internal validity (construct, discriminant and convergent validity, reliability and external validity (relationship with theoretically relevant variables, including job characteristics, home characteristics, burnout, ill health and life satisfaction of the instrument. Motivation for the study: Work-family interaction is a key topic receiving significant research attention. In order to facilitate comparison across work-family studies, the use of psychometrically sound instruments is of great importance. Research design, approach and method: A cross-sectional survey design was used for the target population of married employees with children working at a tertiary institution in the North West province (n = 366. In addition to the new instrument, job characteristics, home characteristics, burnout, ill health and life satisfaction were measured. Main findings: The results provided evidence for construct, discriminant and convergent validity, reliability and significant relations with external variables. Practical/managerial implications: The new instrument can be used by researchers and managers as a test under development to investigate the interference between work and different nonwork roles (i.e. parental role, spousal role, work role, domestic role and specific relations with antecedents (e.g. job/home characteristics and well-being (e.g. burnout, ill health and life satisfaction. Contribution/value-add: This study provides preliminary information on the psychometric properties of a new instrument that measures the interference between work and nonwork.

  4. Conceptual design for the NSTX Central Instrumentation and Control System

    International Nuclear Information System (INIS)

    Bashore, D.; Oliaro, G.; Roney, P.; Sichta, P.; Tindall, K.

    1997-01-01

    The design and construction phase for the National Spherical Torus Experiment (NSTX) is under way at the Princeton Plasma Physics Laboratory (PPPL). Operation is scheduled to begin on April 30, 1999. This paper describes the conceptual design for the NSTX Central Instrumentation and Control (I and C) System. Major elements of the Central I and C System include the Process Control System, Plasma Control System, Network System, Data Acquisition System, and Synchronization System to support the NSTX experimental device

  5. 38 CFR 41.520 - Major program determination.

    Science.gov (United States)

    2010-07-01

    ... major programs. This risk-based approach shall include consideration of: Current and prior audit... of prior audit findings under § 41.510(a)(7) do not preclude the Type A program from being low-risk... this section), except this paragraph (e)(2)(i)(A) does not require the auditor to audit more high-risk...

  6. Environmental policy instruments and technological change in the energy sector: findings from comparative empirical research

    International Nuclear Information System (INIS)

    Skjaerseth, J.B.; Christiansen, A.C.

    2006-01-01

    This article explores the extent to which and in what ways environmental policy instruments may affect patterns of environmental friendly technological change in the energy sector. Our argument is based on the assumption, however, that technological change is also affected by the political context in which the instruments are applied and by the nature of the problem itself. Comparative empirical research involving different European countries, sectors and policy fields were examined, including climate change, air pollution and wind power. The relationship between environmental policy instruments and technological change is extremely complex, not least due to the impact of other factors that may be more decisive than environmental ones. Against this backdrop, it was concluded that: 1) a portfolio of policy instruments works to the extent that different types of policy instruments affect the different drivers and stages behind technological change needed to solve specific problems. The need for a portfolio of policy instruments depends on the technological challenge being faced; 2) voluntary approaches facilitated constructive corporate strategies, but mandatory approaches tended to be more effective in stimulating short term major technological change; 3) voluntary approaches work well in the short term when the problem to be solved is characterized by lack of information and coordination. (author)

  7. The Scope and Limitations of Legal Instruments on Cultural Property in the World Heritage City of Vigan, Philippines

    Directory of Open Access Journals (Sweden)

    Yahaya Ahmad

    2005-12-01

    Full Text Available The World Heritage City of Vigan. Philippines was inscribed in the list of World Heritage Sites in 1999 under criteria (ii and (iv of the Operational Guidelines, after its first submission in 1989 was rejected by the World Heritage Committee. The heritage of the city is now sufficiently protected by eight legal instruments, four enacted at national level and an other four at local level. However, these instruments have limited scope and limitation and, if not rectified, will not be able to safeguard the heritage of the City against rapid development. Presidential Decree No. 374/1974, which has not been revised, has several weaknesses, such as in system of incentives, penalties, the broad terminology and scope of heritage as well as overlapping of tasks and responsibilities between national agencies. The main Local Ordinance No. 04/2000: An Ordinance Enacting the Preservation and Conservation Guidelines for Vigan Ancestral Houses provides solid guidance on the protection of heritage but requires revision related to Section 2 on Definition of Ancestral Houses, Sections 3-16 on Technical Guidelines, Sections 17-22 on Vigan Conservation Council and Section 24 on Penalties.

  8. Performance of a dual readout calorimeter with a BGO electromagnetic section

    International Nuclear Information System (INIS)

    Gaudio, Gabriella

    2011-01-01

    The dual readout technique has been tested on a hybrid calorimeter. The electromagnetic section of this instrument consists of 100 BGO crystals and the hadronic section is made out scintillating and Cherenkov fibers embedded in a copper matrix (DREAM). The electromagnetic fraction of hadronic showers is evaluated on an event-by-event basis from the relative amounts of Cherenkov and scintillation lights produced in the shower development. The performance of such a calorimeter in terms of energy resolution is presented. Effects of side leakage on detector performance are also studied.

  9. The psychometric properties of a shortened corporate entrepreneurship assessment instrument

    Directory of Open Access Journals (Sweden)

    Renier Steyn

    2017-08-01

    Aim: The aim of this research was to evaluate the psychometric properties of a measure of entrepreneurial climate. Entrepreneurial climate was measured using a shortened version of the Hornsby, Kuratko and Zahra (2002 instrument, called the Corporate Entrepreneurship Assessment Instrument (CEAI. Making information on the psychometric properties of the instrument available directly relates to its utility. Setting: The setting was medium to large South African companies. A random sample of employees was drawn from 53 selected companies across South Africa, with 60 respondents per company (N = 3 180. Methods: A cross-sectional survey design was used. Several instruments were administered, including the shortened version of the CEAI. Cronbach’s alpha was used to test for reliability and several methods were used to test for validity. Correlation analysis was used to test for concurrent validity, convergent validity and divergent validity. Principle component factor analysis was used to test for factorial validity and a t-test to test for known-group validity. Results: The results showed that the reliability for the total score of the shortened version of the CEAI was acceptable at 0.758. The results also showed some evidence of concurrent validity, as well as homogeneity among the items. With regard to factorial validity, all items loaded in accordance with the subscales of the instrument. The measure was able to distinguish, as expected, between government organisations and private business entities, suggesting known-group validity. Convergent validity and divergent validity were also assessed. Interesting to note was that entrepreneurship climate correlates more with general employee attitude (e.g. employee engagement; R= 0.420, p < 0.001 and organisational commitment, R = 0.331, p < 0.001 than with self-reported innovation (R = 0.277, p < 0.001 and R = 0.267, p < 0.001. Contribution: This paper not only provided information on the reliability

  10. Seed drill instrumentation for spatial coulter depth measurements

    DEFF Research Database (Denmark)

    Kirkegaard Nielsen, Søren; Munkholm, Lars Juhl; Lamandé, Mathieu

    2017-01-01

    coulter depth varied up to ±5 mm between the blocks. In addition, significant depth variations between the individual coulters were found. The mean depths varied between −14.2 and −25.9 mm for the eleven coulters. The mean shallowest coulter depth (−14.2 mm) was measured for the coulter running...... in the wheel track of the tractor. The power spectral densities (distribution) of the coulter depth oscillation frequencies showed that the majority of oscillations occurred below 0.5 Hz without any natural vibration frequency. The study concluded that the instrumentation concept was functional for on...

  11. Construction and validation of the Self-care Assessment Instrument for patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Simonize Cunha Barreto de Mendonça

    Full Text Available ABSTRACT Objective: to construct and validate the contents of the Self-care Assessment instrument for patients with type 2 diabetes mellitus. Method: methodological study, based on Orem's General Theory of Nursing. The empirical categories and the items of the instrument were elucidated through a focus group. The content validation process was performed by seven specialists and the semantic analysis by 14 patients. The Content Validity Indices of the items, ≥0.78, and of the scale, ≥0.90, were considered excellent. Results: the instrument contains 131 items in six dimensions corresponding to the health deviation self-care requisites. Regarding the maintenance, a Content Validity Index of 0.98 was obtained for the full set of items, and, regarding the relevance, Content Validity Indices ≥0.80 were obtained for the majority of the assessed psychometric criteria. Conclusion: the instrument showed evidence of content validity.

  12. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  13. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Choo, Kee Nam; Kang, Young Hwan; Cho, Man Soon; Sohn, Jae Min; Kim, Bong Goo

    2006-01-01

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  14. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  15. 7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report

    International Nuclear Information System (INIS)

    1992-12-01

    In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R ampersand D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R ampersand D

  16. The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis

    Science.gov (United States)

    Wilson, Gordon R.

    1992-12-01

    For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.

  17. Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan for 2014

    Energy Technology Data Exchange (ETDEWEB)

    Hallbert, Bruce [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Ken [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-07-01

    The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies Pathway conducts targeted research and development (R&D) to address aging and reliability concerns with the legacy instrumentation and control and related information systems of the U.S. operating light water reactor (LWR) fleet. This work involves two major goals: (1) to ensure that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) to implement digital II&C technology in a manner that enables broad innovation and business improvement in the nuclear power plant operating model. Resolving long-term operational concerns with the II&C systems contributes to the long-term sustainability of the LWR fleet, which is vital to the nation's energy and environmental security.

  18. Interactive teaching and learning with smart phone app in Optoelectronic Instruments course

    Science.gov (United States)

    Hu, Yao; Hao, Qun; Zhou, Ya; Huang, Yifan

    2017-08-01

    Optoelectronic Instruments is a comprehensive professional course for senior students majored in optical engineering and similar specialties. Due to the low lecturer/ student ratio, typically less than 1:100, most of the students gave up the chance of one-to-one communication with the lecturers even when they were confused about the principle or applications of the instruments. A smart phone App Rain Classroom associated with messaging App Wechat is introduced. It enables the lecturers to receive instant feedback from students through bullet screen, push preview and review materials and post in-class quiz. Investigation also shows that 76% of the students enjoyed the new interactive tool, acknowledging its help in understanding the topic better, improving in-class interaction, and after class communications.

  19. Nuclear reactor instrumentation power monitor

    International Nuclear Information System (INIS)

    Suzuki, Shigeru.

    1989-01-01

    The present invention concerns a nuclear reactor instrumentation power monitor that can be used in, for example, BWR type nuclear power plants. Signals from multi-channel detectors disposed on field units are converted respectively by LPRM signal circuits. Then, the converted signals are further converted by a multiplexer into digital signals and transmitted as serial data to a central monitor unit. The thus transmitted serial data are converted into parallel data in the signal processing section of the central monitor unit. Then, LPRM signals are taken out from each of channel detectors to conduct mathematical processing such as trip judgment or averaging. Accordingly, the field unit and the central monitor unit can be connected by way of only one data transmission cable thereby enabling to reduce the number of cables. Further, since the data are transmitted on digital form, it less undergoes effect of noises. (I.S.)

  20. The Status of MUSIC: A Multicolor Sub/millimeter MKID Instrument

    Science.gov (United States)

    Schlaerth, J. A.; Czakon, N. G.; Day, P. K.; Downes, T. P.; Duan, R.; Glenn, J.; Golwala, S. R.; Hollister, M. I.; LeDuc, H. G.; Maloney, P. R.; Mazin, B. A.; Nguyen, H. T.; Noroozian, O.; Sayers, J.; Siegel, S.; Zmuidzinas, J.

    2012-05-01

    We report on the recent progress of the Multicolor Submillimeter (kinetic) Inductance Camera, or MUSIC. MUSIC will use antenna-coupled Microwave Kinetic Inductance Detectors to observe in four colors (150 GHz, 230 GHz, 290 GHz and 350 GHz) with 2304 detectors, 576 per band, at the Caltech Submillimeter Observatory. It will deploy in 2012. Here we provide an overview of the instrument, focusing on the array design. We have also used a pathfinder demonstration instrument, DemoCam, to identify problems in advance of the deployment of MUSIC. In particular, we identified two major limiters of our sensitivity: out-of-band light directly coupling to the detectors (i.e. not through the antenna), effectively an excess load, and a large 1/f contribution from our amplifiers and electronics. We discuss the steps taken to mitigate these effects to reach background-limited performance (BLIP) in observation.